Loading...
HomeMy WebLinkAbout10141735.pdfPREPARED 8 0 r"LOT PLAN 1/8t# = it -Off WINDOW SCHEDULE MARK SIZE TYPE MATERIAL NOTES WIDTH HEIGHT 1 41-0") 4t-01I SL VIN. 2 2$-6pt 3 t-014 SL VIN. 3 6 $-00) 4'-0 11) SL VIN, 4 4 -Opp 4 I -Olt SL VIN. 5 4 t-0)) 4 t-OjI SL VIN. DOOR SCHEDULE MARK DOOR SIZE MATL WD HGT THK 001 21-6yy 6"-81) 2 Sc 002 2'— 6') 6 1 — 8 " 21) SC 003 2).- 6 " 6'- 8 3" 21$ Sc I I I (h) k4AKAkxh 11 1 MICROMM F - --I— - -TJrAkTA P30 OUINK"L, 1/411 = 11.0ft A NEW WALLS EXISTING WALLS WALLS TO BE REMOVED 0 X A v-0i, c, e, L . bl, oi, e L Z 714 285 1121 2 017 W. ALCO AVE. SANTA ANA CALIFORNIA 92703 Z MACIELALOMSN.COM 6 REVISIONS w tu o A 0 mm A P A I W. / -\ 0 -- w& A w w .j Z 0 F- ic F- 0 Z SITE: w w IL 0 or CL It 0 Ir 0 0 Ir 0 cc wZ 0 w Z w 0 w 0 F- Z 0 F- U. 0 w 0 w w CC CY w cc to I-- Z w DEvELopr--R OymER.- 0 0 w Mrs. Natividad Gonzalez 0 w 714/ 836-0751 ac 0 w w Joe Dmcmpnm 0 -�% Z w 495 sq.f t I 0 N e'w Roo 0 Acicli�ia� Z 0 0 0 ar a: SHEET NUMBER: ARA m PREPARED B i ii 61-011 171-61t 61-011 51-311 111 41-811 FOUNDATION PLAN 1/411 = 11.011 _ EXIST'G FOOT'G NEW FOUNDATION STRUCTURAL -NOTES CONCRETE 1. ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR WEIGHT HARD ROCK TYPE (150 #/CU. FT.). AGGREGATES SHALL BE NATURAL SAND AND ROCK CONFORMING TO ASTM C-33 WITH PROVEN SHRINKAGE CHARACTERISTICS OF LESS THAN p.05 2. READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94. PLACEMENT OF CONCRETE SHALL CONFORM TO AC 301. 3. CEMENT FOR ALL CONCRETE SHALL BE PORTLAND CEMENT TYPE I, OR II LOW ALKALL CONFORMING TO ASTM C-150. 4.MINIMUM COMPRESSIVE STRENGTH OF CONCRETE AT AGE OF 28 DAYS FOR= FOOTINGS 2500 PSI SLAB ON GRADE 2500 PSI SIDE WALKS 2000 PSI 5. MAXIMUM SLUMP SHALL NOT EXCEED 4' 6. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF 5 DAYS AFTER PLACEMENT. ALTERNATIVE METHODS WILL BE APPROVED IF SATISFACTORY PERFORMANCE CAN BE ASSURED. 7.ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS AND OTHER INSERTS SHALL BE SECURELY FASTENED IN THE FORMS BEFORE CONCRETE IS POURED, ADEQUATE CLEANOUTS SHALL BE PROVIDED IN BOTTOM OF CONCRETE FORMS FOR PROPER CLEANOUT AND INSPECTION. 8, VIBRATION OF .CONCRETE SHALL BE IN ACCORDANCE WITH THE GENERAL PROVISIONS OUTLINED IN PORTLAND CEMENT ASSOCIATION SPECIFICATIONS ST-26, 9. EXPOSED CORNERS OF COLUMNS, BEAM, WALL, ETC. SHALL BE FORMED WITH 3/4 ' CHAMFERS UNLESS DETAILED OTHERWISE. 1O.CONCRETE CONTRACTOR SHALL SUBMIT PROPOSED CONCRETE DESIGN MIX TO THE ARCHITECT AND ENGINEER OF RECORD, PRIOR TO STARTING THE WORK. 11.NO WATER SHALL BE ADDED TO CONCRETE WITH TEMPERATURE IN EXCESS OF 95° F. 12. WIRE MESH LAP (END & SIDE) SHALL BE ONE FULL MESH }2. 10'-011 51-211 PLYWOOD 1. PLYWOOD SHEETS SHALL BE CDX CONFORMING TO PS 1-95 AND SHALL BE STAMPED WITH THE DRPA GRADE OF THE AMERICAN PLYWOOD ASSOCIATION, UNLESS NOTED OTHERWISE ON THE PLANS. 2. EACH SHEET SHALL HAVE A MINIMUM! AREA OF 8 SQ. FT. WITH A MINIMUM DIMENSION OF 2 FEET. 3. SEE FRAMING PLAN FOR DIAPHRAGM NAILING SCHEDULE, NAILING SHALL BE INSPECTED AND APPROVED BEFORE COVERING. FOUNDATION NOTES 1. FOUNDATION HAS BEEN DESIGNED ASSUMING MINIMUM ALLOWABLE SOIL BEARING PRESSURE PER 1997 UNIFORM BUILDING CODE SHALL BE AS FOLLOWS, CONTINUOUS FOOTING = 1000 P. S. F. ISOLATED FOOTING = 1000 P.S.F. 2. ALL FOOTINGS SHALL BE FOUNDED ON OR BELOW FIRM UNDISTURBED NATURAL SOIL, OR APPROVED COMPACTED FILL AND ADJACENT FINISH GRADE UNLESS NOTED OTHERWISE. 3. ALL FOOTING SHALL BE CENTERED ON PILASTER AND/OR WALL AND COLUMN UNLESS OTHERWISE NOTED. 4. FINISH FLOOR (F.F.) EXCAVATION SHALL BE AS NOTED ON GRADING PLANS. 5. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ANY ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. 6. ALL FOOTINGS SHALL BE FORMED TO MEET SIZES INDICATED ON DRAWINGS, DETAILS, AND/OR SCHEDULES. 7. ALL FOOTINS AND PIERS SHALL BE CENTERED UNDER THE BUILDING COLUMNS. (U. N. 0. ) 8. ALL EXISTING UTILITIES THAT INTERFERE WITH THE STRUCTURAL FOUNDATIONS SHALL BE REMOVED AND RELOCATED. 9. ALL PIPES, DUCTS AND CONDUITS WITHIN THE SPHERE OF INFLUENCE OF THE FOOTING, (THE PRESSURE ZONE, EXTENDING BELOW THE FOOTING, . BASED (IN A 2 HORIZONTAL TO 1 VERTICAL SLOPE), SHALL BE SLEEVED THROUGH CONCRETE CAST -IN -PLACE AT THE FOUNDATION POUR. 10. FOUNDATION MAY BE SUBJECT TO STRUCTURAL REVISION IN THE FIELD DUE TO POSSIBLE VARYING SUBSURFACE. CONDITIONS. ' dia. x 10 L° A.B 41 MAX, 12" FROM DS MAX INBEDED T' 1d"x116" WASflERS (ffl.) ►41 X24" 4DATION 1"CESS 211 X611 ZEENED VDATION iT (TYP.) 24" L #4 REBAR DOWE 6" INTO EXIST'G FOOT1 WI WnROCK (TYP) 2 3 2 3 4 s + + E s r 6 ao- .-. a 1- ROOF SHT' G 0/ 2X ROOF RFTR. 7 N 7 PER PLAN (1X6 STARTER BOARD - , -SHIPLAP- AT EXPOSED'EAVES) e 1 _ .. 2- B. N. p 3- (3) - 16d @ RFTR. TIE cd 2- FLR.. SHEAT I NG PER 4- 2X BLK` G W/ A-35 (2 v PLAN 0/ 2X6 F. J. @ 16' 0. C.. U. N. 0. 16 O.C. W/ R-19 INS 5- 2X CEILING JST. 3- 2-2X ELK' G4- PER PLAN 0GIRDER 6- DEL TOP PLATE PER PLAN S- A-35 EA. SIDE 7- 2X STUDS @ 16' O. C. SEE SHEAR WALL SGHED. 18' s 6- 8' X 8' X2' P. T. PLATE OR WD. BM. PER PLAN FOR SHEAR TRANSFER @ W/ 5/8 ' D I A A.. B. 8- SHEAR WALL PER PLAN SHEAR WALLS 7- CONIC. PIER WHERE OCCURS SHEAF TRANSFER 1'=1'-°• CONCRETE PIER AT EAVE 4' -0- (8) 16d @ MIN. L & 2) 16d !STUD 1 2 P TOP PLT. 16d @MAX' O.C. 3 5 @AST 4 4X4- HDR. MIN. FROVIV� IX6 Lff-IN 6 MC'G (11' NO 5WAP, WALL5 OCCUR) @ 60 -- _ 16d @ 24" Mikk @ 45 MIN°W/ - 7 FACE (3) 16d E. N. C 59 CKr/ & M, 5fUP CP.P, EA, 7' 00 NAIL TYP. CORN�P @ 25' O.C, hiM, 8 , 2X TR I M' R & "` 9 ° 1- 2X STUD WALL PER PLAN KING STUDS < 2) 16d E. N. TO 2X SILL PROVIV� 2X ff� BLOCK WHEn WXL5 2- 2X4 PLT. @ JAMB TYP. r-A(,rrv10' H. &Af&1, 18 CLR 3- SHEAR WALL WHERE OCCURS CL'& 50pI;Ir LINe5 G 4- 2X BLK' G OR 2X STUDS 6' a RIM JST. @ 161, O.C. v 5- 1' PLYW' D SHEAT'G PER 12, min PLAN 0/ 2X FLR. JST. C 2) 10d T. N. 2X f .t,P.�. SILL PLT. p a PER PLAN W/ R-19 INS. EA. SIDE STU W/ 5/ 8 11 PIA. ANCPa COL 5 W/ T, ��Mpwlr 6' ----- pp 6- MUDSCREED AT EXT. WALLS TO PLT. f R 1`OUNPAiION f� MP �- 7- A-35 @ 16' 0. C. A, P. ¢ 6-0" O.C, & 4 1/ 2 " 10 8- 2X4 P. T: D. F MUDS ILL W! A. B. ` • MIN, / 12" MAX. rVM. ° SILL END 3• 1 6• 13- PER PLAN W/ 2 X2 X 3/ 16 ' THK. PLATE WASHER °•° • • 9- CONCRETE FTN'G PER PLAN '° 12' "'t" 10- (2> #I4 REBAR TOP & BOT. EXTERIOR BEARING WALL. EXTERIOR FOOTING 1 11 Aid TV %. Z&JL tll' ° A' JA\1'X1V1 " ROOF FRAM'G 1/411 it..011 ROOF SHEAT'G LUMBER I. ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR CONFORMING TO DIVISION 23 (1997 U. B. C. > 2. RAFTER, BEAMS, PURLINS SHALL BE DOUGLAS FIR NO. UNLESS OTHERWISE NOTED t GRADE 3. JOIST, PURLINS 2' TO 4' WIDE, 6' & DEEPER NO. 1 BEAMS, PURLINS OVER 4' WIDE NO. i SUBPURLINS 2' TO 4' WIDE, 6' & DEEPER NO. I LEDGERS NO. 2 STUDS 2' x 4' OR 3' x 4' STUDS STUDS 2' x 6' NO, 1 POSTS 5' x 5' AND LARGER NO. 1 SILLS, PLATES AND BLOCKING NO.2 4. SILLS AND PLATES IS CONTACT WITH CONCRETE OR MASONRY AND WITHIN 49' OF GROUND SHALL BE PRESSURE TRESTED DOUGLAS FIR (PTDF), SILLS SHALL BE BOLTED TO THE FOUNDATION WITH 5/8' DIAMETER x 10' BOLTS AT 48' ON CENTER, 12' MINIMUM FROM ENDS OR 2 BOLTS MINIMUM PER PIECE, UNLESS NOTED OTHERWISE. 5. STUD WALLS ABUTTING A CONCRETE OR MASONRY WALL SHALL BE BOLTED TO THE WALL WITH 5/8' ANCHOR BOLTS AT 24' ON CENTER. 6. ALL NON BEARING STUD WALLS SHALL BE 2 x STUDS AT 16 D.C. WITH 5/8 ' GYP. BOARD EACH SIDE, UNLESS OTHERWISE NOTED. 7. ALL STUD WALLS SHALL HAVE FULL HEIGHT 1 x 6 DIAGONAL LET -IN BRACES AT ENDS AT INTERVALS NOT EXCEEDING 25 FT. O.C. UNLESS OTHERWISE NOTED ON PLANS. BRACES SHALL COVER A MINIMUM OF SIX STUD SPACES. 8. COMMON NAILS SHALL BE USED. 9. FIRE BLOCKING 2 x 1 1/2 ' THICK, SHALL BE PLACED IN STUD WALLS AT CEILING AND FLOOR LEVELS, AT EACH 10' HEIGHT OF STUDS, AND BETWEEN STAIR STRINGERS AT SUPPORTS. 10. JOISTS SHALL BE BLOCKED AT SUPPORTS AND BRIDGED OR BLOCKED AT INTERVALS OF 8' WHERE JOISTS ARE 2 x 12 OR DEEPER. It. MAXIMUM UNSUPPORTED HEIGHT FOR NON -BEARING PARTITION SHALL BE 2 x 4 @ 16' D. C. UP TO 14' - (Y 2 x 6 @ 16' O.C. UP TO 20'-0' 2 x 8 @ 16, B.C. UP TO 26' -(Y 12.PROVIDE DOUBLE JOISTS UNDER PARALLEL BEARING PARTITION WALLS. 13.BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM 1/32' AND A MAXIMUM 1/16 ' LARGER THAN THE BOLT DIAMETER. REINFORCING STEEL 1. REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS AS FOLLOWS FOOTING, SLAB ON GRADE, MASONRY, AND BENT DOWELS, TIES, #3 BAR AND SMALLER ASTM A-615 GRADE 40 #4 BAR AND LARGER ASTM A-615 GRADE 60 2. DEFORMATION OF REINFORCING SHALL BE IN ACCORDANCE WITH ASTM A-305 AND BENDING IN ACCORDANCE WITH ACI 318-95.. 3. MINIMUM CONCRETE COVER OVER REINFORCING REBAR FOR t (EXCEPT AS NOTED OTHERWISE> NOT EXPOSED TO WEATHER OR EARTH 1' EXPOSED TO WEATHER 1 1/2 ' EXPOSED TO EARTH 2' PILASTER, BEAM & COLUMN TIES 1 1/2 FORMED FOOTING AND WALL EXPOSED TO EARTH 2' UNFORMED FOOTING AND WALL EXPOSED TO EARTH 3' SLAB ON GRADE 2' 4. SPLICE IN CONCRETE MINIMUM OF 36 BAR DIAMETER OR 12' WHICHEVER IS GREATER. 5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 AND 1-82. 6. ALL DETAILING OF REIWORCING SHALL COMMI M THE REQUIREMENTS OF A:I 319-95. 7. ALL REINFORCING STEEL, DOWELS, ANCHOR BOLTS, INSERTS, ETC, SHALL BE SECURED IN PLACE PRIOR TO PLACING ANY CONCRETE OR GROUT. 8. ALL. REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-615 GRADE 60. 9. ALL. REINFORCING BAR BENDS SHALL BE MADE COLD. 10. ALL REINFORCING BARS SHALL BE FREE FROM GREASE, RUST, MILL SCALE OR ANY OTHER FOREIGN MATERIAL WHICH MAY AFFECT THE BARS ABILITY TO BOND TO THE MORTAR. 11. REINFORCEMENT THAT IS PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT AS SPECIFICALLY DETAILED IN THESE DRAWINGS OR WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER OF RECORD: 12. ALL REINFORCING STEEL SHALL BE PROVIDED AT ALL POUR JOINTS ON THE DRAWINGS. WHERE LAP AND/OR SPLICE LOCATIONS ARE NOT SPECIFICALLY INDICATED, PROVIDE CLASS 'C" SPLICE PER SCHEDULE. ALL SPLICE LOCATIONS SHALL BE CLEARLY SHOWN ON SHOP DRAWINGS AND APPROVED BY ENGINEER OF RECORD BEFORE FABRICATION. 13. PLACING TOLERANCES AND BAR SUPPORTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR REINFORCING CONCRETE CONSTRUCTION, BY WCRSI. 14. CLEARANCE BETWEEN PARALLEL BARS IN A LAYER SHALL NOT BE LESS THAN 1', NOR 1 BAR DIA., NOR Ix MAX. AGGREGATE SIZE. BARS IN SECOND LAYER SHALL BE DIRECTLY ABOVE BARS IN FIRST LAYER, MIN. DISTANCE BETWEEN LAYERS = 1'. GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE W/ THE 2001 CBC, PLUMBING AND MECHANICAL CODES, THE CEC AND LOCAL ORDINANCES. 2.. VERIFY ALL DIMENSIONS, DO NOT SCALE DRAWINGS. 3. IT SHALL BE THE RESPONSABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON THE SITE PRIOR TO COMMENCING WORK AND IS TO NOTIFY THE OWNER AT ONCE UPON DISCOVERY OF ANY OMISSIONS OR CONFLICTS IN THE DRAWINGS. 4 ALL NAILING TO COMPLY W/ TABLE 23-II-B-1. CBC 1/2" CDX, 24/0 INDEX PLYW'D D W /8cl COMMON NAILS @ 6" ac EN/ BN, 8d @ 10' ac F-IELD, PROVIDE ROOF RADIANT BARRIER PER T - 24@ PLYW'D ROOF SHEAT'G UNDER SIDE ROOF'G MATERIAL. ASPHALT SHINGLE CLASS 'B' OR BETTER TO MATCH EXIST'G SFR W/ # 15 FELT UNDERLAYMENT • e .. r a `714 / 285 1121 2017 W. ALCO AVE. SANTA ANA CALIFORNIA 92703 Z MACIELAL4DMSN. COM ° REVISIONS W W O Q IL 0 Q Ir a W W m Z 0 3 h z SITE: Q. W IL IL It O v Q s- Z O v Q O ac W Z O aC w n Z to w O w yh V Z 0 4e,4 W F- d O W tl! h Z W v DEVELOPER ! 'm Mrs. Natividad Gonzalez w 714/ 836-0751 z Z T h Z x cc 3 v O W W JOB DEs mpTww. U 2 a W 495 sq,f 1E t v W ° New Room DC z Addition O W O 0�1 0 Q Q W r 2 DRAWN: ARA ----------- DATE: _J48_NO: - SHEET NUMER: PREPARED 8 Rmo 141 = 11.0ft ¢� 12 12 41 14 I. TOP W. e s oC � G4 STUCCO TO MATCH (E). SFR C p , 12 ti jr+�..s°+�i.t k F , ]EAST ELE'v'ATION, 1/4" 11_011 0 WW c ao � e ASPHALT SHINGLE TO MATCH (E) SFR SOUTH ELEVATION 141 ASPHALT SHINGLE TO MATCH (E) SFR R.L TOP W.L_ 1 STUCCO) TO r� MATCH (E)` SFR 14Tr. - ..��' Xq AP .n . .............. hh fi x} 4 ��GTIoN � .. L f, Y � ` 5 � 0 s _ U Z d �714 / 285 1121 2017 W. ALCO AVE. SANTA ANA CALIFORNIA 92703 MACIELALOMSN. COM 0 W W 0 oc IL 0 ir a 0 W :n r� W m v, Z O m Z !r W a x CL cc 0 d Z 0 Ix 0 ac W Z 0 d W Z ce W 0 W Z 0 Z 0 U 0 Z Z W 3.1 W W L W W ir m Z ilt REVISIONS SITE: DEVELOPER / OwNER: U 0 i� W Mrs. Natividad Gonzalez = 714/ 836-0751 Z I Z_ U 0 W JoB DESCRIPTION: v Z a W 495 sq,f-t 1r c New Roos) a 0 Addition O m 0 0i Ic 0 ac cc W r DRAWN: ARA CHECKED: DATE: JOB NO: SHEET NUMBER: