HomeMy WebLinkAbout10147062.pdfA. PLANNING AND ZONING 1. BASEMENT CON5TITUTE5 A STORY. ANY BASEMENT CONTAINING A HABITABLE ROOM SHALL BE CONSIDERED A STORY FOR SIDE YARD, KEARYARD AND HEIGHT DISTRICT PURPOSES. 1 2.21 C 1(1), 12.2 1. 1 AB. 2. MAXIMUM DRIVEWAY SLOPE SHALL NOT EXCEED 2 %. [GRADE DETAILS AND TRANSITION SLOPES REQUIRED WHERE SLOPE EXCEEDS 1 2-1/2%. MAXIMUM DRIVEWAY CR055 5LOPE 15 10 %. MAXIMUM SLOPE WITHIN PARKING AREA 15 5 %. 1 2.21 A5(g), INFORMATION BULLETIN# P/ZC 2001-01 (Ecc LADB5.ORG) 3. IN A * R ZONES PARKING 15 NOT PERMITTED IN THE REQUIRED FRONT YARD ANID A 5' 51DF YARD ALONG THE SIDE STREET LOT LINE OF A CORNER LOT. 1 2.21 AG(a). 4. AUTOMOBILES ARE NOT PERMITTED TO BACK ONTO A PUBLIC STREET" OR 5IDFWALK.* 1 2.21 A5(i)1 . *EXCEPT FOR LOCAL STREETS. 5. WALLS: PARKING AND TURNING AREAS WITHIN 1 5' OP PROPERTY LINE MUST BE ENCLOSED BY 5-9" HIGH 50LID WALL. 1 2.21 AGM, (c), (f). B. ROOM -LIGHT, VENTILATION AND DIMENSIONS I . UNDER FLOOR VENTILATION SHALL BE NOT LESS THAN 1 / 150 Of UNDER FLOOR AREA. (230G) 2. ATTIC VENTILATION OF 1 / 150 OF THE AREA OF VENTILATED SPACE (APPROXIMATELY 105Q. IN. FOR EACH 10 SQ. FT. OF ATTIC AREA) 15 REQUIRED. (1505.3) C. SPECIAL HAZARDS 1. GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED. 91 .240G.4 A. INGRESS AND EGRESS DOORS B. PANELS IN SLIDING OR SWINGING DOOR5 C. DOOR5 AND ENCLOSURE FOR HOT TUB, BATHTUB, 5HOWER5 (ALSO GLAZING IN WALL ENCL05ING THESE COMPARTMENTS WITHIN 5',Of STANDING 5URFACE) D. IF WITHIN 2' OF VERTICAL EDGE Of CLOSED DOOR AND WITHIN 5' OF STANDING 5URFACE E. IN WALL ENCLOSING STAIRWAY LANDING 2. SMOKE DETECTORS SHALL BE PROVIDED AS FOLLOWS: A) IN NEW CON5TRUCTION SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER SOURCE FROM THE BUILDING WIRING AND SHALL BF EQUIPPED WITH BATTERY BACK UP AND LOW BATTERY SIGNAL. SMOKE DETECTORS SHALL BE LOCATED IN EACH SLEEPING ROOM * HALLWAY OR AREA GIVING, ACCESS TO A SLEEPING ROOM,AND ON EACH STORY AND BASEMENT FOR DWELLINGS WITH MORE THAN ONE STORY. 3. PROVIDE AN APPROVED SPARK ARRESTER FOR THE CHIMNEY OF FIREPLACE, STOVE, OR BARBECUE. (L.A.M.C. 57.20.25) 4, AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE `RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 171 ,874-FOR WORK OVER $10,000.) 5. WATER HEATER MUST BE STRAPPED TO WALL. SEC. 507.3, UPC D. EXITS AND STAIRWAYS. 1. PROVIDE EMERGENCY FGRE55 FROM SLEEPING ROOMS. MIN.-24" CLEAR HT, 20" CLEAR WIDTH, 5.7 SQ.FT. MIN. AREA * 44" MAX TO SILL. 91 .310.4 2. PROVIDE WINDOW WELLS (WITH FIXED LADER) AT EMERGENCY EGRESS WINDOWS BELOW GRADE. 91 .310.4 3. AT LEAST ONE EXIT DOORWAY SHALL NOT LE55 THAN 3-0" WIDE AND 0-8" HIGH AND SHALL BF 50 MOUNTED THAT THE CLEAR WIDTH OF 32" 15 MAINTAINED. 91.1003.3.1.3a 4. THE DOOR MUST OPEN OVER A LANDING NOT MORE THAN 1 i` BELOW THE THRESHOLD. EXCEPTION: PROVIDING THE DOOR DOES NOT SWING OVER THE LANDING, LANDING SHALL BE NOT MORE THAN 8" BELOW THE THRESHOLD. 91 .1003.3. I . G 5. LANDING AT A DOOR SHALL HAVE A LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 30. 91.1003.3.1.7 G. ENCL05ED U5EABLE SPACE UNDER INTERIOR STAIRS REQUIRES ONE -HOUR FIRE-RES15TIVE CONSTRUCTION ON ENCLOSED SIDE. 91.1003.3.3.9 (SUCH AS 5/6" TYPE X, GYP. BRD.). 7. PROVIDE 3G" HIGH GUARDRAILS WITH LF55 THAN 4" CLEAR SPACING BETWEEN INTERMEDIATE RAIL5. 91 .509.2,3 8. EVERY STAIRWAY SHALL HAVE A HEADROOM OF NOT LF55 THAN G'-8" MEASURED VERTICALLY FROM A PLANE PARALLEL AND TANGENT TO THE 5TAIRWAY TREAD NOSING. 1003.3.3.4 L%Vl Jiti. J ! V iIL J41 ! lii 1 t IiiVl7, i 3/V ✓4/L tt1 Vy RELATED DOOR ASSEMBLY. 91 .302.4. 2. GARAGE SHALL NOT OPEN DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES. 91.312.4 3. THE GARAGE/CARPOKT FLOOR SURFACE SHALL BE OF NONCOMBUSTIBLE OR ASPHALTIC PAGING MATERIALS. THE MINIMUM THICKNF55 OF CONCRETE FLOOR 5LAB5 SUPPORTED DIRECTLY ON THE GROUND SHALL NOT BE LF55 THAN 3-1/2 INCHE5. 91 .31 2.5 F. CONSTRUCTION -GENERAL I . ATTIC (WITH OVER 30" HEADROOM) MUST HAVE ACCF55 OPENING (22"X30" MIN). 91 . 1 505. 1 2. GLASS SKYLIGHT SHALL COMPLY WITH 91 .2409. PLASTIC SKYLIGHT SHALL COMPLY WITH 91 .2GO3.7. 1. 3. A CORR05ION RESISTANT WEEP 5CREED 15 REQUIRED BELOW THE STUCCO A MINIMUM OF 4" ABOVE EARTH 2" ABOVE PAVED AREA. 91 .250G.5 4. THE CONSTRUCTION SHALL NOT RE5TRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCE55 TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLF5, PULL-BOXE5, TRAN5FORMFR5, VAULTS, PUMPS, VALVES, METER5,APPURTENANCE5, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSE5. I.. 'T OF THE G. CLA55 A, B, OR C FIRE -RETARDANT ROOF COVERING OTHER THAN WOOD PITCHING 10 MIN. SLOPE. 91 . 1 503, 91.150G.. I H, MISCELLANEOUS 1. PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. 2. PROVIDE 12" CLEARANCE UNDER FLOOR GIRDERS AND 18" CLEARANCE UNDER FLOOR JOISTS. 91 .230G.3 3. PROVIDE 70 INCH HIGH NON--AB50KDENT WALL ADJACENT TO 5HOWER AND APPROVED 5HATTER-RE515TANT MATERIALS FOR SHOWER ENCLOSURE. 91.607.1.3, 91 .240G.4(5), 9 I .1 1 15B.9. G, 7, 8 1. 5T RU CT U RAL-GENERAL 1. 5O I L: I b c> P 5 l _,a_..,, 2. PLYWOOD =--' � TrL. PANDA .P> 3. PARTICAL BOARD:'''' 4. WOOD FRAMING MEMBERS: -�' '��, -� 1 -- 2- 5. CONCRETE: 5TANDARD 2500p5i CONCRETE. 3000p!3i MIN FOR GRADE BFAM5 AND CAISSONS. 91 . 1905. 1 , 91 . 1921 .2.4. 1 G. CONTINUOUS INSPECTION BY A DEPUTY INSPECTOR 15 REQUIRED FOR . ALL CONCRETE WITH f'c GREATER THAN 2500p5,. 91 . 1701 .5. 1 7. LAG BOLTS: PROVIDE LEAD HOLE 40 %-70 % OP THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH 5HANKPORTION. 91 ND5 9. FOUNDATION 51LL5 SHALL BF PRESSURE TREATED, OR FOUNDATION GRADE REDWOOD. 91 .230G.4 10. PROVIDE DOUBLE. JOLTS UNDER PARALLEL BEARING PARTITIONS. 2320.6.5 J. 5EISMIC-5HEAR WALL5 AND DIAPHRAGM5 1. SOLID BLOCKING SHALL BE PROVIDED AT ALL HORIZONTAL JOINTS OCCURING IN BRACED WALL PANELS. 2320.1 1.3 2. 5TUCCO 5HFAR WALLS SHALL UTILIZE FURRING, GALVANIZED NAILS (HAVING A MINIMUM I I GA., 1-1 /2" LONG, 7/ I G" DIAMETER HEAD, AND FURRED OUT A MIN OF 114") TO ATTACH THE LATH TO THE STUDS. STAPLES SHALL NOT BE USED. 3. 5HEAR WALLS WITH A SHEAR VALUE GREATER THAN 300 plf SHALL USE THE FOLLOWING: A) 3X FOUNDATION SILL PLATES. 5) 3X STUDS AND BLOCKS BETWEEN ADJACENT PANELS. C) 112" EDGE D15TANCF FOR PLYWOOD BOUNDARY NAILING.. D) STAGGER NAILS IF NAIL SPACING 15 LESS THAN 2" O.C. Q SQUARE PLATE WASHERS SHALL BE USED WITH ALL ANCHOR BOLT5. TABLE 23-1I--L 5/8" BOLT-2.5X2.5X 114 7/8" BOLTS-3X3X5/ I G 3/4" BOLT5-2.75X2.75X5/ 1 G I " BOLT5-3.5X3.5X3/8 4. ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. T 23-11-1-1 K. CONNECTIONS 1. ALL BOLT HOLES SHALL BE DRILLED 1 /32 TO I / I G" OVERSIZED. 8. 1 .2.1 , 91 ND5 2. PLATE WASHERS ARE REQUIRED FOR ALL HOLD DOWNS. 2315.5.G L. FOUNDATION AND GRADING 1. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. 7013.9 2. IF ADVERSE 501L CONDITIONS ARE ENCOUNTERED, A 501L5 INVESTIGATION REPORT MAY BE REQUIRED. 1604.2, FIGURE 18-1-2 M. 5ECURITY REQUIREMENTS GENERAL: 1. ALL ENTRY DOORS TO DWELLING UNITS OR QUE5TROOM5 SHALL BE ARRANGED 50 THAT THE OCCUPANT HAS A VIEW OF THE AREA IMMEDIATELY OUTSIDE THE DOOR WITHOUT OPENING THE DOOR. SUCH VIEW MAY BE PROVIDED BY A DOOR VIEWER, THROUGH WINDOWS LOCATED IN THE VICINITY OF THE DOOR OR THROUGH VIEW PORTS IN THE DOOR OK ADJOINING WALL. 91 . G70G 2. SCREENS, BARRICADES, OR FENCE5 MADE OF MATERIAL WHICH PRECLUDE HUMAN CLIMBING SHALL BE PROVIDED AT EVERY PORTION OF EVERY ROOF, BALCONY, OR SIMILAR SURFACE WHICH 15 WITHIN 8 FT. OF THE UTILITY POLE OR 51MILAR STRUCTURES. 9 I .G707 DOOR5: 3. WOOD FLU5H-TYPE DOORS SHALL BE 1--3/6" THICK MINIMUM WITH 50LID CORE CONSTRUCTION. 9 I .G709. 1 - DOOR STOPS OF €N-SWINGING DOORS SHALL BE OF ONE-PIECE CONSTRUCTION WITH THE JAMB OR JOINED BY RABBET TO THE JAMB. 9 I .G709.4 M. 5ECURiTY REQUIREMENTS (CONT.) 8. THE USE OF A LOCKING SYSTEM WHICH CON515TS QF A DEADLOCKING LATCH OPERATED BY A DOORKNOB AND A DEADBOLT OPFRATED BY A NON -REMOVABLE THUMB TURN WHICH 15 INDEPENDENT OF THE DEADLOCKING LATCH AND WHICH MUST BE 5EPERATELY OPERATED, SHALL NOT BE CON5IDERFD AS A 5Y5TEM WHICH REQUIRES SPECIAL KNOWLEDGE OR EFFORT WHEN U5ED IN DWELLING UNITS. THE DOORKNOB AND THE THUMP TURN WHICH OPERATES THE DEADBOLT SHALL NOT BE 5EPERATED BY MORE THAN 8 INCHES. 9. WOOD PANEL TYPE DOORS MUST HAVE PANELS AT LEAST 911 C IN. THICK WITH SHAPED PORTIONS NOT LF55 THAN 1 /4 IN. THICK AND INDIVIDUAL PANELS MUST BE NO MORE THAN 300 SQ. IN. IN AREA, MULLIONS SHALL BE CONSIDERED A PART OF ADJACENT PANELS EXCEPT MULLIONS NOT OVER 18 INCHES LONG MAY HAVE AN OVERALL WIDTH OF NOT LESS THAN 2 INCHES. STILES AND RAILS SHALL BE OF 50LID LUMBER IN THICKNE55 WITH OVERALL DIMEN510NS OF NOT LE55 THAN 1-3/8 INCHES AND 3 INCHES IN WIDTH. 91 .G709. 1 ITEM 2 10. SLIDING DOORS SHALL BE PROVEDED WITH A DEVICE IN THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVING OF THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION. 9 I .G710 1 1. SLIDING GLA55 DOORS SHALL BE EQUIPPED WITH LOCKING DEVICES AND SHALL BE 50 CONSTRUCTED AND INSTALLED THAT THEY REMAIN INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS 5PECIFIED IN 91 .G717. 1 12. METAL OR WOODEN OVERHEAD OR SLIDING DOORS SHALL BE SECURED WITH A CYLINDER LOCK, PADLOCK WITH A MIN. 9/32" DIAMETER HARDENED STEEL SHACKLE AND BOLTED, HARDENED STEEL HA5P5, METAL SLIDE BOARD, BOLT OR EQUIVALENT DEVICE UNLE55 SECURED ELECTRICALLY OPERATED. 91.G71 1 13. PROVIDE METAL GUIDES AT TOP AND BOTTOM Of METAL ACCORDION GRATE OR GRILLF-TYPE DOOR5 AND CYLINDER LOCKS OR PADLOCKS. CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHENEVER THE CYLINDER PROJECT55EYOND THE FACE Of THE DOOR OR 15 OTHERWISE ACCE551BLE TO GRIPPING TOOLS. 9 I .G712 GLAZING: 14. IN B, F, M, AND 5 OCCUPANCIES, PANES OF GLAZING WITH AT LEAST ONE D€MFN5ION GREATER THAN 5 IN. BUT LESS THAN 48 IN. SHALL BE CONSTRUCTED Of TEMPERED OR APPROVED BURGLARY -RESISTANT MATERIAL OR PROTECTED WITH METAL BARS OR GRILLES. 9 I .G714 15. GLAZED OPENINGS WITHIN 40" Of THE DOOR LOCK WHEN THE DOOR 15 IN THE CLOSED POSITION, SHALL BE FULLY TEMPERED GLA55 OR APPROVED BURGLARY RE515TANT MATERIAL, OR SHALL BE PROTECTED BY METAL BARS, SCREENS OR GRILLS HAVING A MAXIMUM OPENING OF 2". THE PROVISIONS µp OF THIS SECTION SHALL NOT APPLY TO VIEW PORTS OR WINDOWS Wtf[cl .l THY' = < DO NOT EXCEED 2" IN THEIR GREATEST DIMENSIONS. 9 I .G713 MEGH Gi WINDOWS: I R 1 G. LOUVERED WINDOWS SHALL BF PROTECTED BY METAL 'BARS OR G, ,_ � � WITH OPENINGS THAT HAVE AT LFA5T ONE DIMENSION OF G" OR WHICH ARE CONSTRUCTED TO PRELUDE HUMAN ENTRY. 91 .G715.3 0 ac . .w 17. OTHER OPENABLE WINDOWS SHALL BE PROVIDED WITH 5UB5TAN1'I`AE - LOCKING DEVICES. IN B, F, M, AND 5 OCCUPANCIES, SUCH DEVICES 51 ski°L� BE GLIDE BAR5, BOLTS, CR055-BAR5, AND/OR PADLOCKS WITH MINIMliw, 9/32" HARDENED 5TEEL SHACKLES AND BOLTED, HARDENED STEEL HA:0!� - 9 I .G71 5.2 16. SLIDING WINDOWS SHALL BE PROVIDED WITH A DEVICE IN THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVING Of THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION. 9 I .G'71 5. 1 19. SLIDING WINDOWS SHALL BE EQUIPPED WITH LOCKING DEVICES AND SHALL BE 50 CONSTRUCTED AND INSTALLED THAT THEY REMAIN INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS 5PECIFIED IN 9 I .G717.2 20. ANY RELEASE FOR METAL BAR5, GRILLS, GRATES OR SIMILAR DEVICES CONSTRUCTED TO PRECLUDE HUMAN ENTRY THAT ARE INSTALLED SHALL BE LOCATED ON THE IN51DF OF THE ADJACENT ROOM AND AT LEAST 24 INCHES FROM THE CL05EST OPENING THROUGH SUCH METAL BARS, GRILLS, GRATES OR SIMILAR DEVICES THAT EXCEEDS TWO INCHES IN ANY DIMENSION. 91 .G71 5.4 4. LLL u OPENING5 OTHER. THAN DOORS OR GLAZED OPENINGS: 3 PRC FEE 21 . ALL OTHER OPENINGS MUST BE PROTECTED BY METAL BARS, OR GRILLES WITH OPENINGS OF NOT LF55 THAN G INCHES IN ONE DIMENSION. 91 .G71 G 5. ALL PIN -TYPE DOOR HINGES ACCE551BLE FROM OUTSIDE SHALL HAVE NON --REMOVABLE HINGE PINS. HINGES SHALL HAVE MIN. 114" DiA. STEEL JAMB STUD WITH 114" MIN. PROTECTION. THE 5TRIKF PLATE FOR LATCHES AND I HOLDING DEVICE FOR PROTECTING DEAD BOLTS IN WOOD CONSTRUCTION SHALL j BE SECURED TO THE JAMB AND THE WALL FRAMING WITH SCREWS NO LE55 THAN 2-1/2" LONG. 91 .G709.5, 91 .G709.7 T c 1`� G. PROVIDE DEAD BOLTS WITH HARDEDED IN5ERTS; DEADLOCKING LATCH'�.-' WITH KEY -OPERATED LOCKS ON EXTERIOR. LOCKS MUST BE OPENABLE FROM INSIDE WITHOUT KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT (LATCH NO'y; Xt Tlt4 ��# 'LA>j/ rLoT FtAA REQUIRED IN B, F, AND 5 OCCUPANCIES. 9 I .G709.2) ` 7. STRAIGHT DEAD BOLTS SHALL HAVE A MIN. THROW OF I " AND AN / 5 8" AND AHOOK-SHAPED OR AN�V/�-"it�;�iS EMBEDMENT OF NOT LF55 THAN l , w u. �� EXPANDING -LUG DEADBOLT` SHALL HAVE A MINIMUM THROW Of 3/41. 9 I .G709 2 u°�� �w `'OLi It;>"T 10 a: x i ij 9A CERTIFICATE Of COMPLIANCE: RESIDENTIAL --- ------- - ---------------- Project Title Project Address ERIC BURNETT Documentation Author Telephone Compliance Method (Package or Computer) CII (Page I of 3) Building Permit # Plan Check/ Date Field Check / Date - - --- --- --- - Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area m ft2 Average Ceiling Height: 8 ft Conditioned 51ab floor Area it 2 f3uildincj Type: X family 5inc3le X Addition (check one or more) Multi -family Existing -Plus -Addition Front Orientation: �®r� Nort 5outh / East / West / All Orientations ---{input front orientation in degrees from True North and circle one) Number of 5torie5 Number of Dwelling -Units: __ Floor Construction Type; 51abrFR i�Fd__Floor (circle one or both) RADIANT BARRIER, (required in climate zones, 2, 4, 8- 15) Required for this submittal X yes no BUILDING ENVELOPE INSULATION Component frame Tyre Cavity Sheathing Total K- Assembly Location/Comments Type wd = wood Insulation Insulation Value i LI-Factor' (attic, garage, typical, etc.) stl = steel R-Value K-value Wd P, 13 1 J.3G 1085 EXTERIOR Roof wd R30 Roof Slab Edge f - ----- ­"'-'------­-___.__ For ­ prescriptive co , I insulation requirementltrpf -,FENESTRATION R-Value - ------------ 7.75 0.03G ATTIC . ............ . .. . . 7.03 0.037 CRAWL5PACE are not requireci tor a 5hadinq Devicec- fenestration Orien- Area fenestration fenestration Exterior Overhangs/ pe/Pq5t___ tation U-factor 5HGC 5had nci Att. fn 5I __f/Ty Front 140 0.35 BUG5CREEN - - - --------- NONE Front Left 0 ).40 .35 BUGSiCREEN NONE Left Rear 140 0.35 13UG5CUEN NONE . ............ Rear BUG5CREEN NONE Compliance forms August 2001 MANDATORY MEA5URE5 CHECKL15T: RESIDENTIAL (Page I of 2)Mf- I R Note: Lownse residential buildings subject to the 5tanciards must contain these measures regardless of the compliance approach used, Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only, Instructions: Check or initial applicable boxes when completed or enter N/A if riot DESCRIPTION _B_uTi� V I - - ------ insulation manufacturer's. 91 (R)_.' manufacturer's labeled P-Valuemay --tn--w—o,o-c-l-,,--w--a-l1-5,-o—r-e-q,t-ji-v--a-ie--n-t-,--U--fa,-c-t-o-,r-i-n"---,frame --walls --,- -wall insulation framed metal (does not apply to exterior mass walls). I (F) --*----,-------"-"--",-,-,,---"—, edge in5ulation - water al:)5orrtion rate no greater than 0.3%, water vapor tran5mo!3ion rate no greater than 2.0 permlinch, - --- -------- insulation specified or installed meets insulation quality Standards. Indicate type and form, - -------------- ---- ------- ---- _Doo­m­,'_and­'I'n ------ i G-17: Fenestration Products, ExteriorControls 1. Doors and window-5 between conditioned and unconditioned Spaces designed to limit air leakage. 2. Fenestration products (except freld-fabricated) have label with certified 1-1-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doom and windows weatheri5trirred; all jornt5 and penetrations caulked and 5ealed. Vaporbarriers mandatory in Climate Zones 14 and I G only, ---ISO{F}c Special inhltiation barrver installed to comply with g 15 ! meets CammiSsion quah£y standards. __— -- -------- ---- I . Ma5onry and factory -built fireplaces have; a, Closeable metal or glass door b. Outside air intake with damper and control 0. flue damper and control 2. No contrnuou5 burning gas pilot lights allowed. - - ---------- - - - _-_ -------------- ----- ----- - -- --- pac -f r6a fing--4ina-PIvn*ifh - - ------------ 0_ I I a HV C equipment h at�erM, 5 eri,, i'�5 6��; a by the �0(h ; Heating and/or cooling loads calculated in accordance with A5HRAE, SMACNA OR AGGA. setback thermo5tat on all applicable heating and/or cooling 5y:5tem5. ........ J.. Pipe and nk in5ulation I . 5torage gas water heaters rated with an Energy Factor Ie55 than 0.55 must be externally wrapped with insulation having an m5talled thermal resistance of K- 12 or greater, 2. Fist 5 feet of pipes closest to water heater tank, non-recirculating5y5tems, insulated (K-4 or greater) 3. Back-up tank-3 for solar System, unfired 5torage tank-5, or other, indirect hot water tank-, have P­ 12 external insulation or K- I G. combined internaltexternal m5ulation . 4. All buried or exposed piping insulated in recirculating 5ection!3 of hot water 5y5tem,3, 5. Cooling system piping below 551F insulated. G, Piping insulated between heating Source and indirect hot water tank. Compliance forms August 2001 CERTIFICATE Of COMPLIANCE: RESIDENTIAL (Page 2 of 3) Cf- I P, Project Title Date HVAC SYSTEMS or combined hydronic data under Water Ileatmcj Systems, except Design Heating Load. Distribution Cleating Equipment Minimum Type and Duct or Heat PUM19 Tyre (furnace, heat Efficiency Location Piping Thermostat Configuration pump, etc.) (AfUE or H5Pf) (ducts, attic, etc.) R-Value Type (split orpackage) GAS FURNACE 78% AFUE DUCTS IN ATTIC A .2 SETBACK 5P LIT Type (air conditioner, Efficiency Location { Duct Thermostat Configuration heat pump, evap, cooling} (SEER) (attic, etc.) R-Value} Type- (split or package) AC5PLIT 10% SEER DUCT5 IN ATTIC 4.2 5ET13ACK SPLIT SEALED DUCTS and TXV5 (or Alternative Mea5ure5) 1_"1 5ealed Ducts (all climate zones) (Installer testing and certification and HER5 rater field verification required) I'J TXV5, readily accessible (climate zones 2 and 8-15 only) (Installer testing and certification and HER5 Rater or field verification required) Refrigerant Charge/Air flow (climate zones 2 and 8- 15 only) (Installer testing and certification and HER5 Rater or field verification required) OR ICI Alternative to 5ealed Ducts and TXVs (see Package C or D Alternative Package Features for Project Climate Zone) Climate Zone Window 5HGC Window U-Factor 5EER, Heating 5 0.35 0.40 WATEK HEATING SYSTEMS Energy' External Rated Tank factor or Tank Water Heater Distribution Number Input (kW Capacity Recovery Standby Insulation Type Type in System or Btuffir) (gallons) Efficiency Loss (1/b) K-Value --- -------- for Small gas 5torage water heaters (rated inputs of le,.-55 than or equal to 75,000 Btu/hr), electric resistance, and heat pump water heaters, list Energy Factor. For large gag storage water heaters (rated input of gr eater than 75,000 Btu/hr), lt,,it Rated Input, Recovery Efficiency and Standby W55, For m5tantaneou5 gas water heaters, lot rated input and recovery efficiencre-3, — -------- --- ------ - -------- SPECIAL FEATURES \H0.9092x;(adJ extra 5heet5 if niece55ary). Package C and D. TXV5, 5ealed Duct5, Radiant Barrici-5 (5CC in5tallation re_61uirement5 for radiant barriers in Section 8. 13 of the 2001 KC50ential Manual), PackaA.S C: thermal ma55 (thermal ma55type, coverincl, thickne55 and die5cription). Compliance Forms August 2001 MANDATORY MEASURES CHECKL15T: RESIDENTIAL (Page 2 of 2)Mf- I R .... . ... .. ...... Note: Lowri5e residential buildings subject to the Standards must contain these measures rejimile55 of the compliance approach used. Items marked with an asterisk M may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only, Instructions: Check or initial applicable LIOXC5 when completed or enter N/A if not -------- -- -- --------- --------- - - -- — ------ ani Fang I All ducts and plenums installed, 5ealed and m5ulated to meet the requirement of the 1996 CIVIC Sections -01, G03, G04, and Standard G-3; ducts insulated to a minimum m5talled level of K-4,2 or enclosed entirely in conditioned 5pace. Openings shall be 5ealed with mastic, tape, aerosol sealant, or other duct -closure 5y5tf in that meets the applicable requirements of UL 18 1, UL 161 A, or UL 1516, If mastic or tape 15 used to Sea openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building ravitie5 shall not be used for conveying conditioned air. Jorm;5 and seams of duct 5y5tem5 and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape 15 w5ed in combination with mastic and drawbands. 2. Building cavities, support platforms for air handler-3, and plenums defined or constructed with materials other than Sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platform-) may contain ducts. Ducts installed in cavities and 5uport platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. 3, Joints and 5earn5 of duct 5y5tern5 and their compnent5 Shall not be 5ealed with cloth back rubber adhesive duct tapes unle55 Such tape r5 used in combination with mastic and drawband5, 4. Exhau5t fan systems have back draft or automatic dampers, 5. Gravity ventilating systems 5ervinq conditioned Space have either automatic or readily accessible, manually operated dampers, G. Protection of Insulation. ln5ulaton!3hall be protected from damage, including that due to 5unlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather Shall be 5uttable for outdoor Service e.g., protected by aluminum, sheet metal, painted canvas, or pla5tic cover. Cellular foam insulation Shall be protected a5 above or painted with a coating that j5 water retardant and provides shielding from Solar radiation that can cause degradation of the material. Heating , y-�tem5 an -- --------- I . 5y5tem r5 certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System 15 in5talled wrath: a. At least 3G" of pipe between filter and heater for future Solar heating. b. Cover for outdoor pools or outdoor 5pa5. 3. Pool 5y5tem has directional inlets and a circulation pump time 5vntch tj - - ---------- - ,pa u5 eaters or oe o cook ng a continuously burning pilot fight. (Exception: Non -electrical cooking appliances with pflot< 150 Btulhr) -9-f (fJ_C .......... -- -- ---------- luminaires or genera ig tin in or greater for general lighting in kitchens. This general fighting Mall be controlled by a switch on a readily acce.-5ible lighting control panel at an entrance to the kitchen. fficacy of 40 Iumem)/watt or greater switched at the entrance to the room or one of the alternative5 to this r quirement allowed in 9 150(k)2,; and incandescent rece5oed ceiling fixtures are IC (m5ulatron cover) a Proved. Compliance Forms August 2001 CERTIFICATE Of COMPLIANCE: RESIDENTIAL (Page 3 of 3) Cf- I K Project Title Date COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts I and G of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been 5icjneci by the individual with overall design responsibility. When this certificate of compliance Is submitted for a single budding plan to be built in multiple orientations, any 5hadinrj, feature that is varied 15 indicated in the Special Features/Remarks section. The undersigned recognize that compliance using duct sealor�"anJ TXV5 requires m5ta4er testing and certification and field verification by an approved HEK5 rater be5ieper or Owner (per Bu51ne55 and Documentation Author Profe551on5i Code) Name- 6�iC Name; Title/firm: VtI Address: Telepl Lic, #: Name: Title: Agency: Telephone. '31-11- $ - ? ent Agency (signature / 5tamp) Compliance forms Telephone: 3 '2- 7o - s-/ 1- 0 (date) (date) August 2001 Z (S) W C) LU (f) D (S) LLI I 0 LLJ LLJ QD 0 0 C\j o (,\j Q) z (V Lu tLj ui R/ (S) (S) IL > ) co > < LU iii � � Q I,,- LU C) Q � � 0 o>�� w L �(-\J 0cocN LLJ LLJ < T) (S) < <�' < > co Ln jv- co Q — (S) I,-- 77 i ED () lU d d tLl lu co QD r > CU 0 U L W iL1 1L �-- (S) (S) to z Ln d Q Ln 77 QD W d C Ln LU (S) (S) In 0(I 0 LLJ U-J 0 cYJ o Q) Cf) z ,5; U-i a/ Li-i LLJ (V To u co LIU > C- AWA APITIT TABLE S USE: PATIO SIZE x 1, SELECT SPAN OF RAFTER 2, SELECT POST SPACING POST SIZE S. SEL,pCT HEADER S!ZF' POST SPACING - HEADER SIZE SPAN OF POST SPACING l I iEi IZE RAFTER Q0 AXlU 8!"-W 4! r-w RAF I tri SPAN; TABLE C RAFTER tmcimr- & SPACING x 4 Q M O.C. TABLE C USE: ROOF PITCH itz . ..... . I SELECT SPAN OF RAFTER 2, SELECT, POST SPACING ROOFING MATERIAL NO SIZE GRAPE OF LUMBER: 0 D.F. NO.1 0 D-F nit SPAN OF RAFTER POST, SPACING 9 r-6. 1 7- 0-121- MT, 0, ...... . .... ........ ........ )"', 3 1/2p CONCRETE SE AR Wl 6X6 FOR STRAP 10110WWF RIDGE AtiAM PER PLAN H001; ISHT10 PER PLAN SIMPSON'SS'STRAP ICBO REPORT NO. 1148 CITY OF L.A. RR# 2946 STUDWALL P.T. PLATE W1 ANCHOR BOLTS 12" MIN FROM ENDS EMBEDED MIN l(r SEE FOUNDATION PLAN FOR SPACING 3 112"CONCRETE SLAH Wl 6X6 10/10 WWF # 4 REBAR 3" FROM TOP & BOTTOM tjr-N-v �n Ili 3 co��-/�, 2�16 T.N. EA; SIDE EA. RAFTER 112- cox PLywu. sHrG W18d @6", 12"; O-C, P.I.:.--32/16 -­ / RAFTER AND RIDGE C.ONN. 2X RAFTERS (Sf,.f.PLAN} IJOOF DIAPHRAGM & NAILING AS PER PLAN (3) 16d NAILS .. ..... 'SIMPSON* A35 0 24- OVC, 2x STUDS, a ur O/C. SHf.'All WALL PER FRAMING PLAN S 0 IMPSON ST 2115 STRAP,W/10-16d -o,, ac. OPPOSING RAFTER MAW fv%f* I r-f% PFR PLAN 4 X BM ON 4 X POST (SEE FRAMING PLAN) AWS a 32"O-C" (TYP-)