HomeMy WebLinkAbout10147626.pdf7- 11) ) 110 11 v,v > V% PLOT PLAN SC=1/8-lw.Owv 0 Of 4 Aen4o g GEINEPAL NOTES ALL 0 1, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 C.B.C. PLUMBING AND MECHANICAL CODES, THE C.E.C. AND LOCAL ORDINANCES. 2. VERIFY ALL DIMENSIONS, DO NOT SCALE DRAWINGS. 3. IT SHALL BE THE RESPONSABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON THE SITE PRIOR TO COMMENCING WORK AND IS TO NOTIFY THE OWNER AT ONCE UPON DISCOVER OF ANY OMISSIONS OR CONFLICT IN THE DRAWINGS. 4. ALL NAILING TO COMPLY WITH TABLE 2341-B-1 C.B.C. 5. THE MANUFACTURED WINDOWS SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE NATIONAL FENESTRATION RATING COUNCIL (NFRC) AND SHOWING COMPLIANCE WITH THE ENERGY CALCULATIONS. 6. LIGHT AND VENTILATION PER CA-C. SECTION 1202. MINIMUM OF 15 C.F.M. OF OUTSIDE AIR PER OCCUPANT IS REQUIRED FOR VENTILATION. PLUMBING NOTES 7. ALL PLUMBING WALLS TO BE 2" x 6" 8. DOUBLE WALLS USED AS PLUMBING WALLS ARE TO BE A MINIMUM OF 8" WIDE AND NO "FLAT" STUDS PERMITTED. STAGGERED STUDS ARE ACCEPTABLE. 9. SMOOTH, HARD, NON ABSORBENT SURFACE IS PROVIDED TO A HEIGHT OF 70" ABOVE THE DRAIN INLET OF THE SHOWER OR TUB/SHOWER COMBINATION, MATERIALS SHALL BE OF A TYPE NOT ADVERSELY AFFECTED BY MOISTURE. 10. GLASS ENCLOSURE DOOR$ AND PANELS MUST BE LABELED CATEGORY If. NET AREA OF SHOWER RECEPTOR SHALL BE NO LESS THAN 1024 SQ IN OF FLOOR AREA, AND ENCOMPASS 130"DIAMETER CIRCLE. 11. ALL WATER CLOSETSMARE LOCATED IN A CLEAR SPACE NOT LESS THAN 30" WIDTH AND HAVE 24" MIN. CLEARANCE IN FRONT OF THE STOOL. 12. FOR EXHAUST VENTILATION AIR, PROVIDE MECHANICAL FAN 6 AIR CHANGES PER HOUR. 13. WATER HEATER TO BE BRACED TO RESIST SEISMIC FORCES, PROVIDE TWO STRAPS (ONE STRAP AT TOP 113 OF THE TANK AND ONE STRAP AT BOTTOM 113 OF THE TANK), 14. ALL NEW WATER CLOSETS WISH USE NO MORE THAN 1.6 GALLONS PER FLUSH. ELECTRIC NOTES 15. RECEPTACLE OUTLETS LOCATIONS WILL COMPLY WITH NEC Art 210-62 (a) -20 AMP. CIRCUIT DEDICATED TO EACH BATHROOM" 16. ALL BEDROOM CIRCUITS REQUIRE ARC -FAULT PROTECTION. 17. GROUND -FAULT CIRCUIT INTERRUPTER (GFQ PROTECTION COMPLIES WITH NEC Art. 210-8: *'ALL 125 volt SINGLE PHASE, 15 AND 20 AMPERES RECEPTACLES INSTALLED IN BATHROOMS, GARAGES, BASEMENTS, OUTDOORS, KITCHEN COUNTERS AND AT WET BAR SINKS. STRUCTURAL NOTES 18. THE CONTRACTOR SHALL PROVIDE ANY SHORING AND/OR BRACING TO THE EXISTING STRUCTURE WICH MAY BE REQUIRED DURING CONSTRUCTION. 19. PERMISSIBLE NOTCHING AND BORING OF JOISTS ARE TO BE SHOWN ON THE PLANS AND SHALL NOT EXCEED CBC SECTION 2320.8.3 ALLOWANCES, 20. NOT OF EXTERIOR AND BEARING INONSEARING WALLS SHALL NOT EXCEED 261/1,140% RESPECTIVELY. BORED HOLES IN BEARING/NONBEARING WALLS $HALL NOT EXCEED 400/o/600/o RESPECTIVELY. IN NO CASE SHALL THE EDGE OF THE BORED HOLE NEARER THAN 6/8" TO THE EDGE OF THE STUD (2320.11.9 AND 2320.11.10) 21. HEADER AND TRIMMER DETAILS FOR DOORS AND WINDOWS ARE TO BE SHOWN WITH THE FULL LENGTH TRIMMERS, SPECIFYING THE SIZE OF THE HEADER AND TRIMMER (2320.11.6) 22. USE SIMPSON ST 6224 TO TIE-IN TO EXISTING TOP PLATES. J terry�A N NG D, jj .... tt MCR, ekl(',­l"'�"U 01 AN' 1 J _4 t 111 -MIA"M $11, > "u 1 ;Q1 'If J STRUCTURAL NOTES CONCRETE 1, ALL CONCRETE UNLESS OTHERWISE NOTED $HALL BE REGULAR WEIGHT HARD ROOK TYPE (150 'CU FT) AGREGATES SHALL BE NATURAL $AND AND ROCK CONFORMING TO ASTM .- 3GRADE JOIST, PURLINS 2'TO, 4" WIDE, 6 & DEEPER No. I C-33 WITH PROVEN SHRINK AGE CHARACTERI$ITCS OF LESS THAN 0.05 %. BEAMS, PURLINS OVER 4- WIDE No, I SUBPURIJNS 7 TO 4- WIDE, 6 & DEEPER No, I 2. READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C- LEDGERS Na. 2 94 PLACEMENT OF CONCRETE SHALL CONFORM TO ACI 301 STUDS 2'x4OR 3"x4" STUDS STUDS Z,xe, NO. 1 1- CEMENT FOR ALL CONCRETE SHALL BE PORTLAND CEMENT TYPE V OR SLOW ALKALL POSTS 5"x S"AND LARGER No. I CONFORMING TO ASTM C-160, SILLS, PLATES AND BLOCKING No, 2 4.- MINIMUM COMPRESSIVE STRENIGHT OF CONCRETE AT AGE OF 28 DAYS FOR: 4.- SILLS AND PLATE$ IN CONTACT WITH CONCRETE OR MASONRY AND WITHIN 48" OF GROUND, SHALL BE PRESSURE TRESTED DOUGLAS FIR (PTDF) SILLS SHALL BE BOLTED TO FOOTINGS 2,500 PSI THE FOUNDATION WITH 51&'DIAMP-TER x 10" LONG BOLTS AT 48" ON CENTER 17'MINIMUM SLAB OR GRADE 2,6W PSI FROM ENDS OR TWO BOLTS MINIMUM PER PIECE, iNLESS OTHERWISE NOTED. SIDEWALKS 2,000 PSI 5,- STUD WALLS ABUTING A CONCRETE OR MASONRY WALL, SHALL BE BOLTED TO THE WALL S.- MAXIMUM SLUMP SHALL NOT EXCEED 4". WITH S/e'ANCHOR BOLTS AT 24" 01C. S.- CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF 5 DAYS 6.- ALL NON BEARING STUD WALL$, SHALL BE 2" x STUDS AT 16"" O/C WITH SYV'GYP. BOARD AFTER PLACEMENT. ALTERNATIVE METODS WILL BE APPROVED IF SATISFACTORY EACH $IDE, UNLESS OTHERWISE NOTED. PERFORMANCE CAN BE ASSURED. Z- ALL STUD WALL$ SHALL HAVE FULL HEIGHT 1" x 6" DIAGONAL LEFT -IN BRACES AT ENDS 7, ALL REINFORCING STEEL ANCHOR BOLTS, DOWELL$ AND OTHER INSERTS SHALL BE AT INTERVALS NOT EXCEEDING 25 FEET 01C UNLESS OTHERWISE NOTED ON PLANS, BRACES SECURELY FASTENED IN THE FORMS BEFORE CONCRETE IS POURED. ADEQUATE SHALL COVER A MINIMUM OF SIX STUD SPACES. CLEANOUTS SHALL BE PROVIDED IN BOTTOM OF CONCRETE FORMS FOR PROPER 8:COMMON NAILS SHALL BE USED. CLEANOUT AND INSPECTION, 8- VIBRATION OF CONCRETE SHALL BE IN ACCORDANCE WITH THE GENERAL PROVISIONS 9.- FIRE BLOCKING 2"x I %"THICK, SHALL BE PLACED IN STUD WALLS AT CEILING AND FLOOR OUTLINED IN PORTLAND CEMENT ASSOCIATION SPECIFICATIONS ST-26. LEVELS AT EACH 10'HEIGHT OF STUDS AND BETWEEN STAR STRINGERS AT SUPPORTS. 9­ EXPOSED CORNERS OF COLUMNS, BEAMS, WALLS, ETC., SHALL BE FORMED WITH 10: JOISTS SHALL BE BNLOCKED AT SUPPORTS AND BRIDGED OR BLOCKED AT INTERVALS CHAMFERS UNLESS DETAILED OTHERWISE. OF V WHERE JOISTS ARE 2'x 12"OR DEEPER, 10, CONCRETE CONTRACTOR $HAL L BE SUBMIT PROPOSED CONCRETE DESIGN MIX TO THE I is MAXIMUM UNSUPPORTE HEIGHT FOR NON -BEARING PARTITION SHALL BE: ARCHITECT AND ENGINEER OF RECORD, PRIOR TO STARTING THE WORK. Tx 4'Q 16" O/C UP TO 14'-0" 2"x S"@ 16" OIC UP TO 20'-T I I, NO WATER SHALL BE ADDED TO CONCRETE WITH TEMPERATURE IN EXCESS OF 95'F. 2"x 8`Q I S'OlC UP TO 26-0" 12- WIRE MESH LAP (END & SIDE) SHALL BE ONE FULL MESH -2 12: PROVIDE DOUBLE JOISTS UNDER PARALLEL BEARING PARTITION WALLS. PLMO!2D 13: BOLTS HOLES IN WOOD MEMBERS SHALL BE A MINIMUM 1/32' AND A MAXIMUM 1116' LARGER THAN THE BOLT DIAMETER, I, PLYWOOD SHEETS SHALL BE COX CONFORMING TO PS 1 -95 AND SHALL BE STAMPED WITH REINFORCING STEEL THE DRPA GRADE OF THE AMERICAN PLYWOOD ASSOCIATION, UNLESS NOTED OTHERWISE ON THE PLANS. I, REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BEARS AS FOLLOWS: 2: EACH SHEET SHALL HAVE A MINIMUM AREA OF 8 $0. FT. WITH A MINIMUM DIMENSION OF FOOTING, SLAB ON GRADE, MASONRY AND BENT DOWELLS, TIES: 2 FEET # 3 BAR AND SMALLER ASTM A- 61 S GRADE 40 # 4 BAR AND LARGER ASTM A- 615 GRADE 60 3, SEE FRAMING PLAN FOR DIAPHRAGM NAILING SHEDULE, NAILING SHALL BE INSPECTED AND APPROVED BEFORE COVERING. 2.-DEFORMATION REINFORCING SHALL BE IN ACCORDANCE WITH ASTM A-305 AND BENDING IN ACCORDANCE WITH ACI-318-95, FOUNDATION NOTES 3, MINIMUM ONCRETE COVER OVER REINFORCING REBAR FOR: I.- FOUNDATION HAS BEEN DESIGNED ASSUMING MINIMUM ALLOWABLE DOIL BEARING (EXCEPT AS NOTED OTHERWISE) NOT EXPOSED TO WEATHER OR EARTH PRESSURE PER 2001 UNIFORM BUILDING CODE SHALL BE AS FOLLOWS: EXPOSED TO WEATHER EXPOSED TO EARTH 2" CONTINUOUS FOOTING 1,000 P.8,F. PILASTER, BEAM & COLUMN TIES I M." ISOLATED FOOTING 1,000 P.S.F. FORMED FOOTING AND WALL EXPOSED TO EARTH 21 2, ALL FOOTINGS SHALL BE FOUNDED ON OR BELOW FIRM UNDISTURBED NATURAL SOIL OR UNIFORMED FOOTING AND WALL EXPOSED TO EARTH 3" SLAB ON GRADE 2" APPROVED COMPACTED FILL AND ADJACENT FINISH GRADE UNLESS NOTED OTHERWISE. 3,- ALL FOOTING SHALL BE CENTERED ON PLASTER ANDIOR WALL AND COLUMN UNLESS 4.- SPLICE IN CONCRETE: MINIMUM OF 36 BAR DIAMETER OR 12'WICHEVER IS GREATER. OTHERWISE NOTED. 4: FINISH FLOOR (F,F) EXCAVATIONI SHALL BE AS NOTED ON GRADING PLANS. S.- WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-1 85 AND "2. 5, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES 6:ALL DETAILING OF REINFORCING SHALL CONFORM TO THE REQUIREMENTS OF ACI 318.95 INCLUDING LAGGING, SHORING AND PROTECTION OF ANY ADJACENT PROPERTY TALL REINFORCING STEEL, DOWELS, ANCHOR BOLTS, INSERTS, ETC. SHALL BE SECURED STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND PLACE PRIOR TO PLACING ANY CONCRETE OR GROUT, LOCAL SAFETY ORDINANCES. 6, ALL FOOTINGS SHALL BE FORMED TO MEET SIZES INDICATED ON DRAWINGS, DETAILS 8.- ALL REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-615 GRADE 60, AND/OR SHEDULES. 7.- ALL FOOTINGS AND PIERS SHALL BE CENTERED UNDER THE BUILDING COLUMNS (U.N.O.) 9.- ALL REINFORCING BAR SENDS SHAL I L BE MADE COLD. ALL EXISTING UTILITIES THAT INTERFERE WITH THE STRUCTURAL FOUNDATIONS SHALL 10.- ALL REINFORCING BARS SHALL BE FREE FROM GREASE, RUST, MILL SCALE OR ANY OTHER FOREIGN MATERIAL WISH MAY AFFECT THE BARS ABILITY TO BOND TO THE MORTAR. BE REMOVED AND RELOCATED, 9-ALL PIPES, DUCTS AND CONDUITS WITHIN THE SPHERE OF INFLUENCE OF THE FOOTING .- REINFORCEMENT THAT IS PARTIALLY EMBEDED IN CONCRETE SHALL NOT BE FIELD SENT I IEXCEPT AS SPECIFICALLY DETAILED IN THESE DRAWING$ OR WITHOUT THE WRITTEN (THE PRESSURE ZONE, EXTENDING BELOW THE FOOTING, BASED ON A 2 HORIZONTAL TO 1 APPROVAL OF THE ENGINEER OF RECORD. VERTICAL SLOPE) SHALL BE SLEEVED THROUGH CONCRETE CAST -IN -PLACE AT THE FOUNDATION POUR. 12.-ALL REINFORCING STEEL $HALL BE PROVIDED AT ALL POUR JOINTS ON THE DRAWINGS, WHERE LAP ANDIOR SPLICE LOCATIONS ARE NOT SPECIFICALLY INIDICATED, PROVIDE 10, FOUNDATION MAY BE SUBJECT TO TRUCTURAL REVISION IN THE FIELD DUE THE CLASS 'C' SPLICE PER SCHEDULE. ALL SPLICE LOCATIONS SHALL BE CLEARLY SHOWN ON POSSIBLE VARYING SUBSURFACE CONDITIONS. SHOP DRAWINGS AND APPROVED BY ENGINEER OF RECORD BEFORE FABRICATION, LUMBER 13.- PLACING TOLERANCES AND BAR SUPPORTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR REINFORCING CONCRETE CONSTRUCTION BY WCRSL l.- ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR LARCH CONFORMING TO DIVISION 23 (2001 C,&Q. 14.- CLEARANCE BETWEEN PARALLEL BARS IN A LAYER SHALL NOT BE LESS THAN V NOR 1 BAR DIA NOR I x MAX AGRAGATE SIZE. 2.- RAFTER, BEAMS, PURLINS SHALL BE DOUGLAS FIR NO. UNLESS OTHERWISE NOTED. BARS IN SECOND LAYER SHALL BE DIRECTLY ABOVE BARS IN FIRST LAYER, MIN DISTANCE ENERGY (TITLE 24) REQUIREMENTS INSULATION EXI WALLS R-13 -ATTIC R-30 FENESTRATION FENESTRATION U-FACTOR-O,,+rPMAX ISHG&0,-40MAX A/C EFFICIENCY N/A RADIANT BARRIER EMISSIVITY LESS OR EQUAL TO 0.05 INSTALLED TO COVER ROOF 14-fraF4 AND GABLE END WALLS AT ATTICS gg , � v : ul � __� PJF R Oil T Y P E EU­ It 76' CONSTR, TYPE --- CODE EDITION F L 0 C D 7- YES '10 ,000 ZCklE. MICROFILM! YES NO t7/ 7 I �4 1. 1111 IF A_ i Isl --a R PLANS the job '0 ud Pt n mgce.ny change$ Or to at al from tho a gtif,agglilwas &aree without vIlUftLe f;ivy ot Sarm Ana. ions SHALL NOT of rjl,!,zn arm Th e 3!.'C e p vi.�-,violaflon of any tn 10,111,11 held to pera itImo.L wovisions Of or State LziL Data A=- OPW BY r, I T y 0 qhN T A. A N A PREPARED BY: 0 -Hiz 714 1 285 1121 ti 2017 W. AL Co AVE. SANTA ANA CALIFORNIA 97703 MACIELALOMSN.COM z a REVISIONS ILI rw O a fr 0 0. _J _J z 0 D z SITE: x w a. 0 0. 0 z 0 0 D z O DEVELOPER / OWNER: I- OWNEt MRS t SOFIA TEJEDA "J* D 0 0 Joa DESCRIPTION: O < a. VMMN OF JOB � 4t:;l 00111111177-11, 77T474 z 0 0 DRAWN: ARA CHECKED: DATE: JOB NO: SHEET NUMBER: ­Amt, NVISIONS By El I � +.,. ..._..........n+2.«v.m.. _....,..., ... y ...—:v++»r..�n«rrm,..y .vw .,._ ,.,. ,. _, _ _ sw.,.,v_.,..,..�..w+-,w,�.rh�+r«.»... _ .-..�..�,.. .,.� ,. _ ..... .., i;y�Y f . /r i ram,,. ,. �..� ____-� ._ � .4+ H,4pe, 0 rn++w+w*.�i�w�ewww.. a .�n... • �•^, �� nw w.wnrwnw+r�rr.e nn �c+ve. .,.w. �, }._• �y CHECKSO . . . . . . . . . . CRATE SCALE tj 0 a r*i 0. SHIBIET A rnimmij un "c^nrmwwt muum IREVISIONS 9 it Y, 72, \1_11 'JON, cow- -5LZ4�p F ==N�A"10mm PLA's Ou M' v5T am im SILL BOLTING ALLOWABLE EXTERIOR INTERIOR SILL NAILING @ MARK WALL TYPE SHEAR WALLS WALLS UPPER STORIES We STUCCO —OVER PAPER —BACKED LAT W11 6 GA STAPLES6- 64 OtG @TOP & BOTTOM PLATES EDGE OF SHEAR WALL AND ON FIELD (ICSO REPORT No. 1823, FES, 1973) OR (ICBO No. 1318, 180PLF 518@55"OIC SfEI@55"OIC FEB, 1973) OR (ICBO No. 1254, FES 1972) NOTE 4 AND 9 BELOW 16d@8`01C 318'PLYWD SRUCT 11 OR STD SHTG WITH Sd NAILS @ T O/C @ EDGES & 12" O/C FIELD 260 PLF 518 @ 3W O/C 518 @ 38"O/C 16d 0 61 0/0 (TABLE 23-11-1-1 U.B.C.) NOTE 10,10 &11 BELOW 318'PLYWD SRUCT 11 OR STD SHTG WITH 8d NAILS @ 4' OIC @ EDGES & 12" O/C FIELD 350 PLF 518 G 26' O/C 518 @ 26' O/C 116d 0 4" DID (TABLE 23-11-1-1 U.B.C) NOTE 1, 6, 9, 10 & 11 BELOW 3/8"PLYIND SRUCT It OR STD SHTG WITH 8d NAILS @,V O/C @ EDGES & 12" O/C FIELD 380 PLF 5/8 @ 26"01C 5/6 @ 26" OIC 16d 0 4' O/C ZA\ TABLE 23414-1 U.B.C.) NOTE 135A% 10 & I I BELOW _ L, , A 3/6"PLYWD SRUCT 11 OR STD SHTG WITH 8d NAILS @ WO/C @ EDGES & 12" OtO FIELD - 490 PLF 518 0 20' OIC 518-0 20" O/C 16d @ (TABLE 23-11-1-1 U.B.C. ) NOTE 1, 3,5,6, 9,10 & 11 BELOW 31121, O/C 31W PLYWD SRUCT 11 OR STD SHTG WITH Bd NAILS @Z' O/C 0 EDGES & 12" OIC FIELD 610 PLF 5/8@16"O/C 5/8@16-0/c 16d @ (TABLE 23-11-1-1 U.B.C. NOTE 1, 3,5,6,9, 10 & 11 BELOW 2 M" O/C 1/2'STRUCT IPLYWD WITH 10d NAILS @ 2' DID @ EDGES & 12" 0/0 FIELD 870 PLF 3f4 @ 16' OIC 3/4 @ 16" OIC N/A OVER 3X STUDS ABLE 23-11-1-1 U.B.C. NOTE 1, 3,5,6,9, 10 & 11 BELOW NOTES: I. ALL EDGES OF PLYWOOD SHEARWALLS MUST BE BLOCKED WITH 2X SOLID BLOCKING FOR WALLS TYPES 9 & 10, AND 3k SOLID BLOCKING FOR WALLS TYPES 11, 12,13 & 14 2.- WHERE SHEAR WALL SHEATING IS TO BE APPLIED TO BOTH SIDES IF WALL, DOUBLE THE NUMBER OF BOLTS. (LE. HALF THE OIC SPACING) 3,- USE 3 x PRESSURE TREATED DOUGLAS FIR SILL PLATES AT FOUNDATIONIFIRST FLOOR ONLY 4.- PAPER BACKED SELF FURRING EXPANDED METAL LATH ICSO APPROVAL S.- GRAMING AT ADJOINING PANEL EDGE$ SHALL BE 3- INCH NOMINAL OR WIDER & NAILS SHALL BE STAGGERED 6., WHERE PLYWOOD IS APPLIED ON BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 6'01C ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3- INCHES NOMINAL OR THICKER & NAILS ON EACH SIDE SHALL BE STAGGERED 7.- ALL CONTINUOUS EXTERIOR FOOTING TO HAVE 518I x I U'A,R's @ 48'O/C UNLESS OTHERWISE NOTED ON PLANS 8, - ALL INTERIOR BEARING AND NON BEARING FOOTINGS TO HAVE 7/32" SHOT PINS @ 32'O/C & 48" 010 RESPECTIVELY: 1. E. OZARK # H-67 ICBO REPORT 1280, MAY 1987 9.- USE 2 V2 x 2 1 a'x ail 6'PLATE WASHERS 10.- USE COX CC OR STD SHTG IN LIEU OF SRUCT It PLYWOOD. ALL PLYWOOD SHALL BE DOUGLAS FIR, OTHER SPECIES MAY REQUIRE CHANGES. I ,- AT EXISTING FOOTINGS USE REOHaY() WEDGE ANCHORS TO COMPLY WITH SILL BOLTING ICBO # 1372 MIN EMBED 7 1 IZ' ANN& mr-m �"%ROF FRAMG PLAP'kim SCMI/4=10-009 'T.W p pu AI I En_a A P L4 r � Tz;, F4 MW —A- � m Ati VOT DRAW 'y.N DA A cmac 'P SCAL, Joe NO. m rhIN I tLJ WN ;;LLIAMPHIMI 10WK PiREPARED BY� MIN HOLD- OWN ANCHOR DIA, EMBED DEPTH EDGE DIST, LOAD CAP HD2A 12" 1- la", 2275 HD5A 12" 144" HD6A, §A 8 15 'L74�t'7460 x� VI u 1, 1�_ >q 1:-� r, I 'A PARAPET ktj Olf USE SIMPSON SET EPDXY j. C.) iCBO* ER5279 OR R.R.R.R25279 0 i 0 1. SIMPSON HD HOLDOWN 2X ROOF JST SHEAR WALL j " PER PLAN PER PLAN TO 4X PST W/ EA. PER PLAN 2, EXISTING CONC. FOOTING A 3. DRILL HOLE 1/16 LARGER A-35 z uj WSJPER PLAIN T 4. THREADED ROD W/ EPDXY ET '/J'DRYWA-L INT ICBO 04945 WALL & CLIG a 201 THAN E30LT DIA. j 16,7 CAI MA D2. I- MIN. 4 EDGE DIST. L — — — — — NOTES; uj A. SPECIAL INSPECTION REQUIRED E # 0 8. DRILL HOLES PER MANUF. SPECS. cc C, A307 THREATEd ROM W/ SIMPSON (L SET EPDXY ICBO -5279 INDICATED EMBEDMENT INTO CONCRETE TO BE MAINTAINED AT RAISED FLOOR FOUNDATIONS fr 0 Ir 17 HOLDWN AT EXISTING FTN'G 13 w 4'-0" MIN, LAP (2) 16d/ STUD t8) 16d MIN. & STUCCO 0/ IBLC*. LOP TOP PLT, 16d 0 16 0. C. PAPER ol 6.1. SPEED 4 0 rtdafl' -i'01* w/ WEEP HOLES 0 STUD - MAX / F, 11 0 4X4 I HDR. MIN. 16d 0 0,C.F NAIL 2X T KING JAI (2) 10 EA. SI TO P 24" ACE (3) 16d E.N. TYP. RIM'R STUDS (2) 16d E. N. B TO 2X SILL T YP, d T. N. Q DE STUD --------------------------------------- PROVIDE 1X6 LET uj ---------- w EXTERIOR BEARING WALL 18 14 '110, k��p 0 FRAMING I_ 1 .111 1 1 1 z OUTER 1/3 I__E 1/3 _ _OYLI_*,R OF SPAN Of' SPAN OF SPAN ONLY AT TOP OR BOT NO NOTCHES AT TOP OR BOT Af_Lnwrn I KI n 0 aD_ 2X STUD �s P(FUR) pw M RM "T (0 MIN) MR PER SCHED HOLD0111IN (HDA)_� tjl t7 '�4 pm pm MIDDLE NOTCHING SPAN ONLY OF SPAN OF SPAN OF SD Al TOP OR BOT NO NOTCHES AT TOP OR 2X At -LOWED U.N.O. LF. k2x PER PLAI sofAu Mk PER WW 0 0 r"N. all SCHEDULE TYPE HD2A H05A H06A HD8A HD10A vff— 2-5/0 2-3/4 3-3/4 3-7/8 4-7/0 _CA& HO 41 -5 11, 1 j_jf t 1/0 6 1 /80 SB - 2 1/,' - r _3 1/2 1/21`3 1/2' CL 1 SO 1 /* 1/21 13/4" 3/4' 31e 16 20 28 28 28 it 16* 24* 2e 240 20 24 34 34 34 Le 16" 20r 28" 28* 28' 2775 4010 5100 7460 9540 2775 14010 -1 5100 1 74M 100 1 0 z z w F A 0 w w ir (0 F z w LM'EIASED ON MIN 0 POST SIZE OR 2 NOM CMMM SITM WW SH41 BE W AWM LOAD. 0 CMIN WW FOR 5/8-0 ANCHM 0 wpm 0 a 0 F DIA. 0 Pr -'A pa#1 - 2X BORING r i r, r-, r MIN FOR 401119.7i M '"0116 MIN, HIP w NOTE- FOR RAISED FMOATION USE SSM FOR r#O POUR SYM EN uj AND EXTEND WLT BEWIND SILL RATE AM n= SHEATHING FRACTION 2X6 2X8 2X10 2X12 2X14 OF JOIST ----------- D/6 1 2 2001 CBC HOLDOWN Z D/3 11/4" 2%'!- 3" 3Y4- SECTION 2320.8.3 NTS 19 15 BORED OR NOTCHED JOIST ---- --------- 0 0) Mow" w z BORED HOLES MAX 40/ OF STUD WIDTH 0 BEARING WALLS, 60/ MAX. to 10 NON -BEARING WALLS. BITUTHENE EXMATCH. ISTV w MIN. -UP Q. 0 BUILT NOTCHES- MAX. DEPTH 25X OF STUD ROOF 0 WIDTH @ BEARING WALLS, 40X MAX. Q NON -BEARING WALLS. 2X RAFTERS EILIK B.N 0 RPPEDI/4"/FT TO ORAN z STUD 0 ....... ... . 2X BLK'G 0 W/ A-35F 0 vi 24" O.C.. 0 cr w FRACTION OF STUD 2X4 2X6 2X8 NOTE: NOTCH & BORE NOT TO OCCUR ON SAME STUD WITHIN 36" OF EACH OTHER. 1)rlt)l (100 � I DRYWALL NT WALL CUG z < 251 D 1/8" IV ly8,, 40/ D 1%" 2 60Z D_ _2"_1 -3'/4" 4/4"__ um�c I ae,9 M10,11 e, L 714 1/ 285 1121 7 W. ALCO AVE. SANTA ANA .IFORNIA 92703 CIELALOMSN-COM REVISIONS SITE: DEVELOPER / OWNER: Aft, Z DRAWN: ARA CHECKED: DATE: JOB NO: SHEET NUMBER: SD=l P,PEPARED B 2X STUDS 6 16 " O.C. W1 2X P.T.D.F. SILL 6" PLT. 4 A.B. PER PLAN 04 REBAR DOWELL AT 24" 7 O.0 AT 2-POUR OPTION hod- z py 1 41 lav— 7777 LOCATION OF RE INF. AT 2 - P.70URe OPT'N 04 BAR TOP 4 BOT r< ----------- MIN. SEE PLAN CON.. FT'ds PER PLAN 12" MIN. CURB AT GARAGE BITUTHENE TO -MATCH EXIST'G) BUILT-UP ROOF 2X RAFTERS FT 4 RIPPEY/"!FT BLK B.N. < TO ORAL 2X IILWG W/ A-35F 24" O.C_ 1/j- DRYWALL INT WALL & CUG 2X STUDS @ roll D.C. OR WD. BM. 2- PARAPET MJL, 2X ROOF JST SHEAR WALL PER PLAN PER PLAN A-35 PER PLAN '/J' DRYWALL NT WALL & CL'G 4 FULL HEIGHT STUDS 22-0" ROOF OVERHANG .S LINE A-1 7 GFI/ WP 14" )< 6" G.1 'D 0 M t: CALIFORNIA FRAMED CRICKET TO DRAIN GARGE \/ESCREENNTS SCUPPER 1/4" 1 FT MIN. O 00 x 2 t: A I/d,v FT CL PI CH G GFI/ FI/ WP WP 2X'12. R.R. 0 16" O.C. % RIPPED 2" TO DRAIN C14 0 21'-5" GARAGE 66 . ...... i��o g oe_ 3 F06 V81 110 V OUTLET S) se, FOR GAR, OPENER is3 Cl 4X12 CONT. OF* 2 —00 (FULL LENGHT OVER SIMPSON STRON WALLS) 16070 O.H. GAR DR. /P)i NA-1) _97'_oll 22'-0" FULL HEIGHT STUDS FLOOR & FRAMING PLAN ELECTRICAL LEGEND CEILING MOUNT. FLUOR. LIGHT ROOF SHEATING110V OUTLET 15/32" COX PLYWOOD (OR OSB), UNBLOCKED. WALL MOUNTED LIGHT 8d 0 6" O.C. SUPPORTED ENDS 9, BOUNDARY 8d 0 12" O.C. FIELD. SWITCH ROOFING ROOFING MATERIAL TO BE BUILT-UP ROOF INISTALLED PER MANUFACTURER'S INSTRUCTIONS AND PER TABLE 15-F UBC SHEAR WALL SCHEDULE (1998 CBC) SHEAR PANEL DISCRIPTION EXTERIORON FOUNDATI ANCHOR BOLTS INTERIOR FOUNDATION ANCHOR BOLM TOP ANCHORAGE I SIMP. A35 (F) STUCCO/LATH 16 GA SlT:'AP:L:E S: ------------- 16" O.C. i JS COX PLY 8d 0 O 6"•/C 1 SIDE GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE W/ THE 2001 CBC, PLUMBING AND MECHANICAL CODES, THE 2001 CEC AND LOCAL ORDINANCES. 2.. VERIFY ALL DIMENSIONS, 00 NOT SCALE DRAWINGS. 3. IT SHALL BE THE RESPONSABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON THE SITE PRIOR TO COMMENCING WORK AND IS TO NOTIFY THE OWNER AT ONCE UPON DISCOVERY OF ANY OMISSIONS OR CONFLICTS IN THE DRAWINGS. 4 ALL NAILING TO COMPLY W/ TABLE 23-11-8-1. CBC 000001WID LET -IN DIAG. BRACED"`\ 600 TYP. Z: 22-0" FULL HEIGHT STUDS '---coNcRETE CURB- roll wjoE CONCRETE SL 8 (4" THK. W1 100/100 uIWF OVER 2" SAND OVER COMPACTED EARTH TROL JOINT I" SAW CUT. \\'—EXTERIOR CONCRETE FOOTIf 46. (12" W X 12" 0 W1 (1) 4N 84 TOP A BOTTOM MIN) Y,A < v& u ... .. ... ... —ONE c"s 7 Sim A-1 L 16'-4" R.O. L L 22'-0" FULL HEIGHT STUDS FOUNDATION PLAN __ 60, /411- L" 14" X 6" GJSCREED LARGE VENTS G.I. STUCCO G.I. STUCCO SCREEED SCREEED Aiw m,, SOUTH Em a, ALL EXTERIOR WALL TO BE SECURED WITH 12" A.B:S 6 12" O.C. WITH 7 MIN. EMBEDMENT, (s 12" FROM ENDS MAX. AND 41/2'1 MIN. 2 PER FIEL MIN.), UNLESS OTHERWISE NOTED, AND WITH MINIMUM 2" )< 2" X 3/16" THICK PLATE WASHER UNDER NUT 0 EACH BOLT. STUCCO EXT,TO MATCH HOUSE'S G.I. STUCCO _j SECTIONAL GAR. SCREEED DOOR 7\ L m 220' 0 T M C'1 af� z 714 2017 W. ALCo AVE. SANTA ANA CALIFORNIA 92703 MACIELALOMSN.COM Z a REVISIONS w w 0 /\ 0 ('L A 10 A I m /\ 0 A L a. E w co z 0 f— Q D cr I'll to [z SITE: z < I iL w 0 z 0 to 0 0 m cc w DRAWN: ARA CHECKED: DATE: — JOB NO: SHEET NUMBER: