HomeMy WebLinkAbout10147502.pdfFO PROPOSED ROOMADDITION • r •1 1405 RENE DR. i-)-- ANALISIS AREA (E) S.F.R. AND GARAGE (N) PROPOSED ROOM ADDITION TOTAL LOT RATIO LOT SIZE % LOT COVERAGE 16070 GRGE. DR. r e e A 1- Sii..�,�.��.. U) z (E) WALLS TO REMAIN z� (N) WALLS (E) WALLS TO REMOVE AND an i GENERAL NGTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 C.B.C. PLUMBING AND MECHANICAL CODES, THE C.E.C. AND LOCAL ORDINANCES. 2. VERIFY ALL DIMENSIONS, DO NOT SCALE DRAWINGS. 3. IT SHALL BE THE RESPONSABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON THE SITE PRIOR TO COMMENCING WORK AND IS TO NOTIFY THE OWNER AT ONCE UPON DISCOVER OF ANY OMISSIONS OR CONFLICT IN THE DRAWINGS. A ALL NAILING TO COMPLY WITH TABLE 2341-B-1 C.B.C. 5. THE MANUFACTURED WINDOWS SHALL HAVE A LABEL -ATTACHED CERTIFIED BY THE NATIONAL FENESTRATION RATING COUNCIL (NFRC) AND SHOWING COMPLIANCE WITH THE ENERGY CALCULATIONS. 6. LIGHT AND VENTILATION PER C.B.C. SECTION 1202. MINIMUM OF 15 C.F.M. OF OUTSIDE AIR PER OCCUPANT IS REQUIRED FOR VENTI,LATON. PLUMBING NOTES 7. ALL PLUMBING WALLS TO BE 2" x 6" & DOUBLE WALLS USED AS PLUMBING WALLS ARE TO BE A MINIMUM OF W WIDE AND NO "FLAT' STUDS PERMITTED: STAGGERED STUDS ARE ACCEPTABLE. 9. SMOOTH, HARD, NON ABSORBENT SURFACE IS PROVIDED TO A HEIGHT OF 70" ABOVE THE DRAIN INLET OF THE SHOWER OR TUBISHOWER COMBINATION, MATERIALS SHALL BE OF A TYPE NOT ADVERSELY AFFECTED BY MOISTURE. 10. GLASS ENCLOSURE DOORS AND PANELS MUST BE LABELED CATEGORY 11, NET AREA OF SHOWER RECEPTOR SHALL BE NO LESS THAN 1024 SO, IN. OF FLUOR AREA, AND ENCOMPASS 30" DIAMETER CIRCLE 11. ALL WATER CLOSETSMARE LOCATED IN A CLEAR SPACE NOT LESS THAN W' WIDTH AND HAVE 24" MEN. CLEARANCE IN FRONT OF THE STOOL. 12. FOR EXHAUST VENTILATION AIR, PROVIDE MECHANICAL FAN 5 AIR CHANGES PER HOUR 13. WATER HEATER TO BE BRACED TO RESIST SEISMIC FORCES, PROVIDE TWO STRAPS (ONE STRAP AT TOP 113 OF THE TANK AND ONE STRAP AT BOTTOM 113 OF THE TANK). 14. WATER CLOSETS SHALL BE AN ULTRA LOW FLUSH TYPE WITH 1.6 GALLONS MAXIMUM PER FLUSH. 15 CONTROL VALVE FOR SHOWER OR TUB -SHOWER SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. 16. PROVIDE DEVICES TO ABSORB HIGH PRESSURES RESULTING FROM THE QUICK CLOSING OF THE QUICK -ACTING VALVES FROM THE WASHER AND DISHWASHER, ETC.. ELECTRIC NOTES 17. RECEPTACLE OUTLETS LOCATIONS WILL COMPLY WITH NEC Art 210-52 (a) "20 AMP. CIRCUIT DEDICATED TO EACH BATHROOM" I& ALL BEDROOM CIRCUITS REQUIRE ARC -FAULT PROTECTION. 19. GROUND -FAULT CIRCUIT INTERRUPTER (GFI) PROTECTION COMPLIES WITH NEC Art. 210-8: "ALL 125 volt SINGLE PHASE, 15 AND 20 AMPERES RECEPTACLES INSTALLED IN BATHROOMS, GARAGES, BASEMENTS, OUTDOORS, KITCHEN COUNTERS AND AT WET BAR SINKS, STRUCTURAL NOTES 20. THE CONTRACTOR SHALL PROVIDE ANY SHORING AND/OR BRACING TO THE EXISTING STRUCTURE WICH MAY BE REQUIRED DURING CONSTRUCTION. 21. PERMISSIBLE NOTCHING AND 130RING OF JOISTS ARE TO BE SHOWN ON THE PLANS AND SHALL NOT EXCEED CBC SECTION 2320:8.3 ALLOWANCES. 22. NOTCHING OF EXTERIOR AND BEARINGINONBEARING WALLS SHALL. NOT EXCEED 25% / AO% RESPECTIVELY. BORED HOLES IN BEARINGINONBEARING WALLS SHALT. NOT EXCEED 40010160010 RESPECTIVELY. IN NO CASE SHALL THE EDGE OF THE BORED HOLE NEARER THAN 5/8" TO THE EDGE OF THE STUD (2320.11.9 AND 2320.11.10) 23. HEADER AND TRIMMER DETAILS FOR DOORS AND WINDOWS ARE TO BE SHOWN WITH THE FULL LENGTH TRIMMERS, SPECIFYING THE SIZE OF THE HEADER AND TRIMMER (2320.11.6) 24. USE SIMPSON ST 6224 TO TIE-IN TO EXISTING TOP PLATES. x..at..i CODE EDITION 0? F1..2. OD;w��jvE hJ .xaa..mxau. FLOOD" ZONE- CERTIF ter-Q' YES Y!E! �NO ti d. cwn FSu" a .. U IRM L S T F." � X 'ITS r 75.�a � GA% .r3®the a, aq et qui Nllisgicil from the " aft E s sr'on SR,,Je �Y.aS iSins:a> 3$ 1j 0( Soma Ana. The o ept n of this Pan end SPO N,.c. $ NOT e hold to permit nor r o& i g ti vo,"Osi of any provisions of ANY CitY Ordina6ceor State L l . 11 Accepted _- t0 rITY OF SANTA ANA rREPARED BY DH'AFTING t' rac lI Mqciel 2017 W. ALCOAVE PHONE 714 / 285-1121 rSANTA ANA, CA 92705 macielalmsn.com REVISIONS �Ittl�r" z< U) < Lr) F� C) < U) T� U) ■ ■ Owner: Mrs. Gabriela Saidana Ph # 7141957-1553 Description of Job. 534Sq. Ft. Room Addition New Mtr Bdrm w/ Bathroom A.P.N. # 109-315-05 Sheet: mvx� �9- � Z x R'COLLAR TIES @ 46'o/c NORTH ELEVATION SC 1/4 � I =0 ASPHALT SHINGLE TO MATCH (E) S.F.R. ASPHALT SHINGLE TO MATCH (E) S.F.R. an 12 3 1 — 3 IDEll F.L. \ (E) 24" x 1801 FOUNDATION ACCESS SOUTH ELEVATION 12 12 3 1WIX 18 A 3 VENTILATION STUCCO TO MATCH (E) S.F.R. F.L. F.GP' M T.O.P. W.L. .STUCCO TO MATCH (E) S.F.R. 00 F.L. ZO00) 4. E;. F.G. 12" x 6" FOUNDATION VENTILATION (TYP) vv V=Ovv EAST ELEVATION scl/4 \ (N) 24" x 18!' FOUNDATION ACCESS F=--1 ASPHALT SHINGLE TO MATCH (E) S.F.R. 12 12 3 3 R.L. T.O.P. F.L. F.G. Wl. CO to OD 17 M 2017 W. A NCO AVE PHONE 714 / 285-1121 SANTA ANA, CA 92705 macielal@msn.com REVISIONS . Owner: Mrs Gabriela Saldana Ph # 714 / 957-1563 Description of Job: 6�4 Sq. Ft. Room Addition New Mtr Bdrrn w/ Bathroom . ............. Sheet: A�2 I FLOR SLIEATINS %" T&G PLYWOOD W/8d @ 611 o1c ENIBN & 8d @ 101, o1c FIELD . tv 1W 16070 GRGE, DR. -7 /-7- /--7-/—/ NEW FOUNDATION I In � I 9=01018 FOUNDATION PLAN SC 4 'ROOF SHEATING CDX, 24/o INDEX PLYWOOD W/ 8d COMMON NAILS @ 6" EN/BN. 8d @ 10" O/C FIELD. PROVIDE ROOF RADIANT BARRIER PER T-24 AT PLYWOOD UNDERSIDE ROOFING MATERIAL ASPHALTH SHINGLE CLASS'B'OR BETTER TO MATCH (E) S.F.R.UNDERLAYMENT ivv,m I ROOF FRAMING PLAN SC 4 Is 2017 W. A LCO AVE PHoNE 7141 285-1121 SANTA ANA, CA 92705 macielal@msn.com REVISIONS Owner: Mrs. Gabriela Saldana Ph # 714 1957-1563 Description of Job: i q. Room Addi�it. New Mtr Bd wl Bathroom"l, '2119 Sheet-., S �l STRUCTURAL NOTES CONCRETE I.- ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR WEIGHT HARD POCK TYPE (150 'CU FT) AGREGATES SHALL BE NATURAL SAND AND ROCK CONFORMING TO ASTM C-33 WITH PROVEN SHRINK AGE CHARACTERISITCS OF LESS THAN 0.05 W 2.- READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94 PLACEMENT OF CONCRETE SHALL CONFORM TO ACI 301. 3.- CEMENT FOR ALL CONCRETE SHALL BE PORTLAND CEMENT TYPE V OR BLOW ALKALL CONFORMING TO ASTM C-1 50. 4,- MINIMUM COMPRESSIVE STRENGHT OF CONCRETE AT AGE OF 28 DAYS FOR: FOOTINGS 2,600 PSI SLAB OR GRADE 2,500 PSI SIDEWALKS 2,000 PSI 5.- MAXIMUM SLUMP SHALL NOT EXCEED 4, 6.- CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF 5 DAYS AFTER PLACEMENT. ALTERNATIVE METODS WILL BE APPROVED IF SATISFACTORY PERFORMANCE CAN BE ASSURED. 7.- ALL REINFORCING STEEL ANCHOR BOLTS, DOWELLS AND OTHER INSERTS SHALL BE SECURELY FASTENED IN THE FORMS BEFORE CONCRETE IS POURED, ADEQUATE CLEANOUTS SHALL BE PROVIDED IN BOTTOM OF CONCRETE FORMS FOR PROPER CLEANOUT AND INSPECTION. 8.- VIBRATION OF CONCRETE SHALL BE IN ACCORDANCE WITH THE GENERAL PROVISIONS OUTLINED IN PORTLAND CEMENT ASSOCIATION SPECIFICATIONS ST-26. 9.- EXPOSED CORNERS OF COLUMNS, BEAMS, WALLS, ETC., SHALL BE FORMED WITH 3/4" CHAMFERS UNLESS DETAILED OTHERWISE. 10.- CONCRETE CONTRACTOR SHALL BE SUBMIT PROPOSED CONCRETE DESIGN MIX TO THE ARCHITECT AND ENGINEER OF RECORD, PRIOR TO STARTING THE WORK. 11.- NO WATER SHALL BE ADDED TO CONCRETE WITH TEMPERATURE IN EXCESS OF 95 * F. 12.- WIRE MESH LAP (END & SIDE) SHALL BE ONE FULL MESH -2 PLYWOOD 1.- PLYWOOD SHEETS SHALL BE CDX CONFORMING TO PS 1-96 AND SHALL BE STAMPED WITH THE DRPA GRADE OF THE AMERICAN PLYWOOD ASSOCIATION, UNLESS NOTED OTHERWISE ON THE PLANS. 2.- EACH SHEET SHALL HAVE A MINIMUM AREA OF 8 SQ, FT. WITH A MINIMUM DIMENSION OF 2 FEET. 3.- SEE FRAMING PLAN FOR DIAPHRAGM NAILING SHEDULE, NAILING SHALL BE INSPECTED AND APPROVED BEFORE COVERING, FOUNDATION NOTES I,- FOUNDATION HAS BEEN DESIGNED ASSUMING MINIMUM ALLOWABLE DOLL BEARING PRESSURE PER 2001 UNIFORM BUILDING CODE SHALL BE AS FOLLOWS: CONTINUOUS FOOTING 1,000 P.S.F, ISOLATED FOOTING 1,000 P.S.F. 2,- ALL FOOTINGS SHALL BE FOUNDED ON OR BELOW FIRM UNDISTURBED NATURAL SOIL OR APPROVED COMPACTED FILL AND ADJACENT FINISH GRADE UNLESS NOTED OTHERWISE. $,- ALL FOOTING SHALL BE CENTERED ON PLASTER ANDIOR WALL AND COLUMN UNLESS OTHERWISE NOTED, 4.- FINISH FLOOR (F,F) EXCAVATION SHALL BE AS NOTED ON GRADING PLANS. 5- THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ANY ADJACENT PROPERTY STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. 6.-ALL FOOTINGS SHALL BE FORMED TO MEET SIZES INDICATED ON DRAWINGS, DETAILS ANDIOR SHEDULES. 7.- ALL FOOTINGS AND PIERS SHALL BE CENTERED UNDER THE BUILDING COLUMNS (U.N.O.) 8: ALL EXISTING UTILITIES THAT INTERFERE WITH THE STRUCTURAL FOUNDATIONS SHALL BE REMOVED AND RELOCATED. - 9.- ALL PIPES, DUCTS AND CONDUITS WITHIN THE SPHERE OF INFLUENCE OF THE FOOTING (THE PRESSURE ZONE, EXTENDING BELOW THE FOOTING, BASED ON A 2 HORIZONTAL TO I VERTICAL SLOPE) SHALL BE SLEEVED THROUGH CONCRETE CAST4N- PLACE AT THE FOUNDATION POUR. 10.- FOUNDATION MAY BE SUBJECT TO TRUCTURAL REVISION IN THE FIELD DUE THE POSSIBLE VARYING SUBSURFACE CONDITIONS. LUMBER I.- ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR LARCH CONFORMING TO DIVISION 23 (2001 C.B.C). 2- RAFTER, BEAMS, PURLINS SHALL BE DOUGLAS FIR NO. UNLESS OTHERWISE NOTED 3.- GRADE JOIST, PURLINS 2"TO4'WIDE, 6& DEEPER No. I BEAMS, PURLINS OVER 4" WIDE No. I SUBPURLINS 2- TO 4- WIDE, 6 & DEEPER No. I LEDGERS No, 2 STUDS 2'x 4" OR 3x 4" STUDS STUDS 2'x 6' No. I POSTS 6'x 5" AND LARGER No. I SILLS, PLATES AND BLOCKING No, 2 4,- SILLS AND PLATES IN CONTACT WITH CONCRETE OR MASONRY AND WITHIN 48', OF GROUND, SHALL BE PRESSURE TRESTED DOUGLAS FIR (PTDF) SILLS SHALL BE BOLTED TO THE FOUNDATION WITH 518' DIAMETER x 10' LONG BOLTS AT 48' ON CENTER 12' MINIMUM FROM ENDS OR TWO BOLTS MINIMUM PER PIECE, INLESS OTHERWISE NOTED. 5.- STUD WALLS ABU`rING A CONCRETE OR MASONRY WALL, SHALL BE BOLTED TO THE WALL WITH 518" ANCHOR BOLTS AT 24'0/C. 6,-ALL NON BEARING STUD WALLS, SHALL BE 2x STUDS AT 16, 010 WITH 5/8" GYP, BOARD EACH SIDE, UNLESS OTHERWISE NOTED. 7.- ALL STUD WALLS SHALL HAVE FULL HEIGHT V x 6" DIAGONAL LEFT -IN BRACES AT ENDS AT INTERVALS NOT EXCEEDING 25 FEET O/C UNLESS OTHERWISE NOTED ON PLANS, BRACES SHALL COVER A MINIMUM OF SIX STUD SPACES. 8,- COMMON NAILS SHALL BE USED, 9,- FIRE BLOCKING 2'x 1 1/, " THICK, SHALL BE PLACED IN STUD WALLS AT CEILING AND FLOOR LEVELS AT EACH 10' HEIGHT OF STUDS AND BETWEEN STAIR STRINGERS AT SUPPORTS. 10.- JOISTS SHALL BE SNLOCKED AT SUPPORTS AND BRIDGED OR BLOCKED AT INTERVALS OF 8' WHERE JOISTS ARE 2x 12" OR DEEPER. I I. MAXIMUM LINSUPPORTE HEIGHT FOR NON -BEARING PARTITION SHALL BE: 2'x 4'@ 16'01C UP TO 14W 2"x 6'@ 16'01C UP TO 20'-0" 2" x 8" @ 16" O/C UP TO 26'-0' 12.- PROVIDE DOUBLE JOISTS UNDER PARALLEL BEARING PARTITION WALLS. 13.- BOLTS HOLES IN WOOD MEMBERS SHALL BE A MINIMUM 1/37AND A MAXIMUM 1116" LARGER THAN THE BOLT DIAMETER. REINFORCING STEEL I.- REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BEARS AS FOLLOWS: FOOTING, SLAB ON GRADE, MASONRY AND BENT DOWELLS, TIES: # 3 BAR AND SMALLER ASTM A- 615 GRADE 40 # 4 BAR AND LARGER ASTM A-615GRADE 60 2.- DEFORMATION OF REINFORCING SHALL BE IN ACCORDANCE WITH ASTM A-305 AND BENDING IN ACCORDANCE WITH ACI-318-95. 3.- MINIMUM ONCRETE COVER OVER REINFORCING REBAR FOR (EXCEPT AS NOTED OTHERWISE) NOT EXPOSED TO WEATHER OR EARTH 1. EXPOSED TO WEATHER 1 Y211 EXPOSED TO EARTH 21 PILASTER, BEAM & COLUMN TIES I%, FORMED FOOTING AND WALL EXPOSED TO EARTH 21 UNIFORMED FOOTING AND WALL EXPOSED TO EARTH 3' SLAB ON GRADE 2' 4.- SPLICE IN CONCRETE: MINIMUM OF 36 BAR DIAMETER OR 12'WICHEVER IS GREATER. 5.-WELDED WIRE FABRIC SHALL CONFORM TO ASTM AA 85 AND 1-82. 6.- ALL DETAILING OF REINFORCING SHALL CONFORM TO THE REQUIREMENTS OF ACi 318- 95 7.-ALL REINFORCING STEEL, DOWELS, ANCHOR BOLTS, INSERTS, ETC. SHALL BE SECURED PLACE PRIOR TO PLACING ANY CONCRETE OR GROUT. 8,- ALL REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-615 GRADE 60. 9,-ALL REINFORCING BAR SENDS SHALL BE MADE COLD. 10,- ALL REINFORCING BARS SHALL BE FREE FROM GREASE, RUST, MILL SCALE OR ANY OTHER FOREIGN MATERIAL WISH MAY AFFECT THE BARS ABILITY TO BOND TO THE MORTAR. I I,- REINFORCEMENT THAT 18 PARTIALLY EMBEDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT AS SPECIFICALLY DETAILED IN THESE DRAWINGS OR WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER OF RECORD. 12.-ALL REINFORCING STEEL SMALL BE PROVIDED AT ALL POUR JOINTS ON THE DRAWINGS, WHERE LAP ANDIOR SPLICE LOCATIONS ARE NOT SPECIFICALLY INIDICATED, PROVIDE CLASS 'C' SPLICE PER SCHEDULE, ALL SPLICE LOCATIONS SHALL BE CLEARLY SHOWN ON SHOP DRAWINGS AND APPROVED BY ENGINEER OF RECORD BEFORE FABRICATION. 13.- PLACING TOLERANCES AND BAR SUPPORTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR REINFORCING CONCRETE CONSTRUCTION BY WCRSI. 14- CLEARANCE BETWEEN PARALLEL BARS IN A LAYER SHALL NOT BE LESS THAN V NOR I BAR DIA NOR Ix MAX AGRAGATE SIZE. BARS IN SECOND LAYER SHALL BE DIRECTLY ABOVE BARS IN FIRST LAYER, MIN DISTANCE BETWEEN LAYERS 1". SILL BOLTING MARK WALL TYRE ALLOWABLE EXTERIOR INTERIOR SILL NAILING -- --------- @ SHEAR WALLS WALLS UPPER STORI ES 7/8'STUCCO OVER PAPER BACKED LATW116 GA STAPLES@ 6" O/C @TOP& BOTTOM PLATES, EDGE OF SHEAR WALL AND ON FIELD (ICBO REPORT No. 1823, FEB, 1973) OR (ICBO 180 PLF 518 @ 59- O/C 5/8 @ 55" O/C 16d @ 8" O/C No. 1318, FEB, 1973) OR ICBO No. 1254, FEB 1972) NOTE 4 AND 9 BELOW rt 3/8'PLYWD SRUCT 11 OR STD SHTG WITH 8d NAILS @ 6" OIC @ EDGES & 12" 01C FIR D 260 PLF 5/8 @ 38" O/C 5/8 @ 38" O/C 16d @ 6- O/C (TABLE 23-11-1-1 U.B.C.) NOTE 1,9,10 & 11 BELOW 3/8" PLYWD SRUCT If OR STD SHTG WITH 8d NAILS @ 4" 01C @ EDGES & 12" O/C FIELD 350 PLF 5/8 @ 26" OIC 518 @ 26" O/C 16d @ 4" O/C (TABLE23-11+1 U.B.C.) NOTE 1, 6, 9, 10 & 11 BELOW 3ff'PLYVVD SRUCT 11 OR STD SHTG WITH 8d NAILS @ 4- O/C @ EDGES & 12" O/C FIELD 380 PLF 518 @ 26' OIC 5/8 @ 26" O/C 16d @ 4�' O/C - - --------- (TABLE23-H-1-1 U.B.C.) NOTE 1, 3,5,6,9, 10 & 11 BELOW 1 3/8" PLYWD SRUCT 11 OR STD SHTG WITH 8d NAILS @ T'01C @ EDGES & 12" O/C FIELD 490 PLF 5/8 @ 20"01C 5/8 @ 20 O/C ri 16d @ 3 1/2" O/C (TABLE2341-1 U.B.C.) NOTE 1, 3,5,6,9, 10 & 11 BELOW 3/8" PLYWD SRUCT 11 OR STD SHTG WITH 8d NAILS @ 2" O/C @ EDGES & 12" OIC FIELD 610 PLF 5/8 @ 16" OIC 5/8 @ 16- O/C 16d @ 2 1/2" O/C (TABLE23-11-t-1 U.B.C.) NOTE 1, 3, 5; 6, 9, 10 & 11 BELOW 1/2'STRUCT IPLYWD WITH 1 Od NAILS @ 2'01C @ EDGES & 12'0/C FIELD 870 PLF 3/4 @ 16" OIC 3/4 @ 16" 01C WA OVER 3X STUIDS(TABLE 23-11-1-1 U.B.C.) NOTE 1, 3, 5, 6, 9, 10 & 11 BELOW NOTES', 1r A LL tUUt:S Of- F LYMOU -5H IzAKWALLS M US I 15h tJ LQ(;KtU WI f H Zx SOLID BLOCKING FOR WALLS TYPES 9 & 1D, A ND 3 x SOLID BLOCKING FOR WALLS TYPES 11 V, 13 & 14 2.-WHERE SHEAR WALL SHEATING IS TO BEAPPLIED TO BOTH SIDES IF WALL, DOUBLE THE NUMBER OF BOLTS. (I.E. HALF THE O/C SPACING) 3- USE 3 x PRESSURE TREATED DOUGLAS FIR SILL PLATES AT FOUNDATION/FIRST FLOOR ONLY 4- PAPER BACKED SELF FURRING EXPANDED METAL LATH ICBO APPROVAL S.- GRAM ING AT ADJOIN ING PA NEL EDGES SHALL 8 E 3- INCH NOM INA L OR WIDER & NAILS SHALL B E STA GGERED 6: WHERE PLYWOOD IS APPLIED ON BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 6" OIC ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAM ING M EM 8 ERS OR FRAM ING SHALL BE 3- INCHES NOM INAL OR THICKER & NAILS ON EACH SIDE SHALL BE STAGGERED --- — -------- 7.-ALL CONTINUOUS EXTERIOR FOOTING TO HAVE 5f8'x IY'A B"s @ 48" OIC UNLESS OTHERWISE NOTED ON PLANS SHOT PINS @ 32" 01C & 48- O/C RESPECTIVELY: I.E. OZA RK # H -67 IC50 REPORT 1280, M AY 1987 B-ALL INTERIOR B EA RING A NO NON BEARING FOOTINGS TO HAVE 7/32 9,- USE 212 x 2 12" x 31 W PLATE WASHERS ---------- 10- USE CDX CC OR STD SHTG IN LIEU OF SRUCT It PLYWOOD -ALL PLYWOOD SHALL 8 E DOUGLAS FIR. OTHER SPECIES M AY REQUIRE CHANGES. 11 AT EXISTING FOOTINGS USE REDHEAD WEDGE ANCHORS TOCOMPLY WITH SILL BOLTING ICBO# 1372MIN EMBED 7 12" 12.- USE DOUBLE FLOOR JOISTS BELOWALL PARALLEL SHEARWALLS U.O.N. 13- AT FLOOR LEVELS USE SOLID BLOCKING AT PERPENDICULAR SHEARWALLS AND DOUBLE FLOOR JOISTS AT EACH END OF THE SHEARWALL. 14. ALL BEAMS SUPPORTING SHEARWALLS MUST BE STRAPPED TO THE WALLS BELOW, 15-ALL HOLDOWNS ON UPPER LEVEL MUST BE CONNECTED TO A POST BELOW PER HOLDOV\N SCHEDULE TO THE LOWER LEVEL OR TO THE FOUNDATION. ------- ------- -- --------- ---- ------- Id Ea 2" x W* X or 4'-0- 141N. LAP 8) 16d @ MIN. 11 @ LASTUB—, P TOP PLT. 16d @ MAX 16' O,C. I 04 HDR MIN 16d 0. C. NAIL 2X T KING @ JA (2> EA. TO PI x 6" Starter Board x 4!' 32" o1c Notch - 2" x V' Dbl Too Plate X W, 2) 16d / STUD 24' ACE (3) 16d E. N, TYP, STUDS'l (2> 16501 E. ft TO 2X SILL TYP. PROVIDE IX6 LET -IN BRAC'G (IF NO SHEAR WALLS OCCUR) @ 60 MAX. @ 45 MIN. W/ (3) 8ol EA. END & EA. STUD BRACE EA. CORNER @ 25' D. C. MAX. PROVIDE 2X FIRE BLOCK WHERE WALLS EXCEED 10' H, & AT ALL CL' G & SOFFIT LINES -2X STUDS @ 16' U. C. 6X P, T. D. F, S I Lh PhT. W/ /8 - DIA. A CH R 0 k7s W/ -7 EMBEDT E OUNDATION PLAN. PROVIDE 0' 0, C. . & 4 1/2 I /,IP' MAX. FRM, CITI I r,A 0 1- 2X STUD WALL PER PLAN 2- 2X4 PLT. 3- SHEAR WALL WHERE OCCURS 4- 2X BLK'G OR RIM JST, 5- 1' PLYW'D SHEAT'G PER PLAN 0/ 2X FLR, JST. PER PLAN W/ R-19 INS, 6- MUDSCREED AT EXT. WALLS 7- A-35 @ 16' D. C. 8- 2X4 P. T. D. F MUDSILL W/ & B. PER PLAN W/ ? 1/2 *X2 1/2 X 3/16 ' THK. PLATE WASHER 9- CONCRETE FTN'G PER PLAN 10- < 2) #4 REBAR TOP & BUT. EXTERIOR FOOTING 18' sq_; 1 4X4 POST WHERE OCCURS W/ ST6215 EA. SIDE FLR. SHEATING PER PLAN 0/ 2X6 F. J, 16' O. C. W/ R-19 INS 3- 2-2X BLK'G 4- 4X6 GIRDER 5- A-35 EA, SIDE 6- S' X S' X2' P. T. PLATE W/ 5/8 * D I A A., B. 7- CONC. PIER I EXTERIOR BEARING WALL (4p4-VAfV ) I CONCRETE PIER 1 2 1 3— & _4 + SCHEDULE TYPE E HD 2A HD5A HD6A HD8A HDIOA Bf2-5/8 2-3/4 3-3/4 3-7/8 4-7/8 /DIA i Post per plan z xStud HB", 41/2" 5 11,V 5 118" 61/8" 61/6' (4 x min) 1! ie' r SB 2 1/2" 3" 31/2" 3 1/2" 3 112" CL 1 1/2" 2 1/16" 2 1/16" 2 1116' 21116" W13 per sch6di SO 114, 1/2" 3/4' 3/4' 314' . . ......... S ......... SSTB# + (HDA) 1 16 20 28 28 28 'Holdown pour per plan 1 Le t 12 16 24 24 24 tJD .............. ranefted SSTB# 20 24 34 34 34 1,2x 2 pour L 16 20 28 28 28 2-2x Les ninembed Allowable Slmpson or 3x load (133) 2775 4010 5100 7460 9540 M mbe-d I S;S: per plan WIM ..... . ... ..... Per Schedule Allowable min cir (w) 277 5 7460 9540 EWthquake Note Concret Stem Walls shall be: ILoads '6" min widht for 518" o Anchors based on min 4x post size or max anchor load min widht for 718- o Anchors .............. ...... . .......... -- ----------- i Note For raised foundation use SST8 for 8" min for cone pour system and extend bott beyond 7nn_J__ .... ......... .. ...... sl plate above floor sheating . ....... I- ROOF SHT'G 0/ 2X ROOF RFTR. PER PLAN (1X6 STARTER BOARD -SHIPLAP- AT EXPOSED EAVES) 2- t N. 3- (3)- 16d @ RFTR, TIE 4- 2X BLKG W/ A-35 @ 16' 0, C. , U. N. 0. 5- 2X CEILING JST. PER PLAN 6- DBL TOP PLATE PER PLAN 7- 2X STUDS @ 16' O.C, OR WD. BM, PER PLAN 8- SHEAR WALL PER PLAN WHERE OCCURS SEE SHEAR WALL SCHED.- FOR SHEAR TRANSFER @ SHEAR WALLS ISHEAR TRANSFER 10=11-011 4 AAV T EE PREPARED tARED Y pi ]RED DBY D AI T I lG, ArjacOi Mociel 2017 W. A LCO AVE PHONE 714 / 285-1121 SANTA ANA, CA 92705 macielalifcbmsn.com REVISIONS Z� L LU ■ CD < LO F� 6j (D < c.� s- Ci,� Owner: Mrs Gabriela SaIdana Ph # 714 / 957-1563 Description of Job: 5 -?, - �-+ S . Ft. Rom oition New Mtr B rm w/ Bath Sheet: