HomeMy WebLinkAbout10146659.pdfN FLOOR & ELECTR CAL SCALE 1 /40 11 PLAN I — a FLOOR PLAN NOTES FA-1 AT ALL SLEEPING ROOMS & ROOMS OR PASSAGES PROVIDE A HARD —WIRED SMOKE DETECTOR W/BATTERY BACKUP, AND BATTERY OPERATED SMOKE DETECTORS AT EXISTING BEDROOMS WHICH SHALL BE AUDIBLE THROUGHTOUT THE STRUCTURE. [0] ATTIC ACCES MIN. 22 $1 x,30" OPENING W/MIN. 30 11 CLEARENCE ABOVE. NEW ADDITION AND EXISTING HOUSE ARE GOING TO BE HEATED BY A NEW C.H.U. THAT IS GOING TO BE INSTALLED AFTER THE ADDITION IS FINISHED. [_D1 ALL CONSTRUCTION SHALL COMPLY WITH 2001 CALIF. BUILDING CODE INCLUDING SEC. 2320 AND MIN. NAILING WITH TABLE 23-11—B-1. DOOR & WINDOW SCHEDULE M K. QUANT. SIZE DESCRIPTION 0 (5) 6 — 0"x4 0" SLIDING WINDOW (2) 2'-6'-8' " J1x6 /� I SCWD �m 0 1 6 11 0 1 x6 11 — 8 SLIDING WARD (1) 6 — 0 x6 — 8" SLIDING DOOR ALL WINDOWS DUAL GL., ALUM. FRAMED WITH GRIDS SANTA ANA POLICE DEPARTMENT RESIDENTIAL SECURITY REQUIREMENTS I Exterior swinging doors must be solid core, 1 -1/4" thick or with panels 9/16" thick. (8-2 1 O.A) 2, Doors leading from a garage into a dwelling unit must be solid core, 1 3/8" thick, (8-210.13) 3, Specify that above doors be equipped with deadbolt locks approved by the Police Department (8-21 O.C) specify make and model number. (Titan 780 or Equal) 4, Specify flush bolt with 5/8" itribedment into head and threshold on inactive leaves of exterior double doors. (8-210.E) 5. Glazing in exterior doors or within 40" of the latch must be tempered or burglary resistant (8-210.F) 6. Hinges for out swinging doors ;must have non -removable pins (NRP). (8-2 1 O.G) 7. Strike plates must be 3 1/2" long, secured to the jamb with screws 2 !/2" in length. (8-2 1 O.H) 8. Front exterior doors to be equipped with ISO door viewers or clear vision panels. (8-2 10. 1) 9. Each structure must have a street address or other identification , which is visible from the street. Figures must be 4" minimum in height of a color contrasting to the background. (8-210. KI) 10. Provide an illuminated plot plan of the complex at each driveway entrance. (8-210.K2) 11. Specify light fixtures, at exterior doors, which provide one foot candle of light at ground level. (8-2 10, L) 12. Parking lots and parking structures of multiple dwelling complexes must be provided with one foot candle of light.. (8-21 ON) 13, Required exterior light fixtures must be vandal resistant types. 14. Wooden garage doors must have panels 5/16" in thickness. (8-208.A1) 15. Garage doors more than 16 feet in width must have two locking points. (8-208.C) 16. Slide bolt assemblies must be attached to the doorframe with non -removable bolts. (8-208.D) I The Slide bolt must be 3/8" in diameter. (8-208.D) & Windows and sliding glass doors must comply with test standards of section 8-212. Specify make and model number. (8-209.A) If not approved must install slide bolts and peAPPI�o devices in upper track of window and door. V, V, 19. Louvered window may not be used within 12' vertically or 6'horizontally from any walkway surface. 20. All skylights shall be provided with rated burglary resistant glazing. (8-210 (revised 10-31-03) VIA. NH 9141 P[ANING1 AU 4 Orp-_IJ UN CR, ACAN()'), 1_ZItI PLA4N-NffN,6 kEQUIRUED tC,0N.'rAC'flad -1,01s4E, (7141667-27 `✓ 3-70 SF A th,;% �Aew bd fvyi c- d (vi viej bdwm f-0 CLIvLp &nf Al( mate-nalsito LE" IFT Ypyff This se, 0i 'TIst n't all tlurl &" MM's Of from '220"'afions -2' "';D i2hnwt rwtho I� 1 t y o f 8 v, 12 A rho acce, tar,-,-o of vms rftn and i,',-IALL NO'T ,,s beld to pnrfl�. nor "nnf' novisions Of ANY City Ordinanco, r Skatlz� Law, K4,j kccepP 2- ted By MUM o _Zt U 0 Z Q�� 0—) Q�� U �D < � 0 �_ D Z � N Q I I I V) D DRAWN BY-, DANIEL CONTRERAS 2060 NEWPORT BLVD. # 15 COSTA MESA, CA 9 949-548-4057 CHECK BY: DATE: 12/13/04 SCALE: 1/411— 1 0 11 SHEET NO.- 1 of 5 REVISIONS BY: m N.a ASSESORY PARCEL No. 408-076-14 T TE PLAN � SCALE 1/8"=V-0" FRAMING PLAN SCALE 1 /4"_ 1:_ D„ n I I DRAWN BY: DANIEL. CONTRERAS 2060 NEWPORT BLVD. # 15 COSTA MESA, CA 92627 9449-548-4057 CHECK BY: DATE: 12/13/04 SCALE: 1 /4ff�13_�11 SHEET NO: 2 of 5 REVISIONS BY: STUCCO FINISH TO MATHC EXISTING CLASS "A" ASPHALT—, /,s/,%L in e*,ei-ri r\K i ej iik j ^i r-� ATTIC VFNTq ELEVATION ROOF PITCH---,, ATTIC' \/FKITq BACK ELEVATION STUCCO FINISH co TO MATHC EXISTING NEW ADDITION RIGHT ELEVATION ATTIC VENTS 1633x8l' CLASS "A" ASPHALT COMPOSITION SHINGLES �n LEFT ELEVATION ' l� EXISTING STUCCO FINISH DRAWN BY: DANIEL CONTRERAS 60 NEWPORT BLVD. # 1 COSTA MESA, CA 92627 949-548-4057 CHECK BY: DATE: 12/13/04 SCALE: 1/4 SHEET NO: 3 of 5 REVISIONS BY: NOTE: NEW CONCRETE MINIMUM STRENGT OF 2500 PSI, 2x4 PREASSURE TREATED SILL PLATE W/ 5/8"XI0" A.B.03'-O*O.0 &12" FROM ENDS EMBEDED 7- W/2- SO. x 3/16* WASHERS (TYP). NEA MIN. OF 2-10Dx1-1/2 DETAIL #6 2x4 PREASSURE TREATED SILL PLATE IAI /O"V4 n" A IM n"^ 0.4 FOUNDATION PLAN 1/2 SCALE 3/8"=1'—O" A-1 n r')Ir\/",r- ME awlj WA&MV-1 EXISTING FOOTINGS SIN) -,+x I z U 1­1 /A 1 14 L_7 r- 171% DETAIL #8 (E) C. J. 1/2- DRYWALL 04'-02x4 PRESS—TRT'D W/5/8x10A.B. " O.C. EMBEDED 70 IN CONC. & 12- OF A CORNER W/2- SQ.x3/16 WASHERS (TYP.) OPENING OFL\ SPLICE MIN. 2-PER SILL SHORT PIECES (TYP.) 4" CONC. SLAB 2" SAND & POLY COMP. Sol 2 #4 BARS CONTINOUS CONC. FOOTING MIN, STRENGTH--' OF 2500 PSI DETAIL #1 SIMPSON LU HANGER TYP. DETAIL #5 2x4 STUD @16" O.C. STUCCO R 13 INSUL. WEEP SCREED 2 0 r Z 12" MIN. DETAIL #3 MIN. TO MATCH EXIST. HOUSE PITCH—\ 12 2x4 FREEZE BLOCK 31 2x4 FACIAL BOARD 2x4 STUD 016" O.C.-----' R-13 INSUL. SECTION AA SCALE 1/2"=1*-0* .S ED 2x8 C.J. 016" O.C. R-30 INSUL. 1/2" DRYWALL 2x4 STUD @16" O.C. DETAIL EXISTING F I DETAIL #4 2x4 Bt MID-Hbum i vm MAX. 8'-D* 1/2" PLYWOOD CDX EXT. W/BD06", 6", 10- O.C. /I--- 2x6 RAFTER 016" O.C. B.N.= 8d@ 4" O.C. 2x4 BLOCKING 2x4 FACIA BOARD 5-8d MIN. —SIMPSON A35 @ 32" O.C. 2-2x4 CONTINIOUS PLATE 7/6/16D NAILS -STUCCO 2x8 CONTINOUS OVER EXISTING ROOF DOW OPENING SHOWN )R OPENING SIMILAR 2x4 STUDS 0 OPNG -0* TO 6'-0' 2x4 STUDS CIS" O.C. IOW SILL 3x4 SILL PLATE TYPICAL STUD WALL FRAMING SEE DETAIL 3 2x1O RIDGE BOARD 2x6 RAFTER 016' O.C. c 00 4" CONCRETE SLAB I ) 1=111 --I ... I 11-111 r SEE DETAIL 2 2XI5 C.J. 016" O.C. W/R-30 INSUL. SEE DETAIL 1 1 151 4Ui DRAWN BY: DANIEL CONTRERAS 2060 NEWPORT BLVD. # 15 COSTA MESA, CA 92627 949-548-4057 CHECK BY: DATE: 12/13/04 SCALE: 1/4 SHEET NO: 4 of 5 VISIONS BY: GENERAL NOTES POURED -IN -PLACE CONCRETE 1. REINFORCING STEEL SHALL COMFORM TO ASTM GRADE 40. 2. REINFORCING FABRIC SHALL COMFORM TO ASTM A185, AND SHALL LAP 1-1/2 SPACES (12"). 3. LAP ALL REINFORCING STILL A MINIMUM OF 36 BAR DIAMETERS (2 -0 MINIMUM) AT ALL SPLICES UNLESS NOTED OTHERWISE. 4. SPLICE ALL REINFORCING STEEL WHERE INDICATED WHERE SPLICE LOCATION ARE NOT SPECIFICALLY INDICATED, SPLICES SHALL BE WELL STAGGERED. 5. MINIMUM CLEAR DISTANCE BETWEEN REINFORCING STEEL, INCLUDING SPLICED AREAS SHALL BE 1" OR 1 BAR DIAMETER WHICHEVER IS GREATER, MINIMUM CLEAR DISTANCE AT COLUMNS SHALL BE 1-1/2" OR 1-1/2 BAR DIAMETERS, WHICHEVER IS GREATER. 6. MINIMUM CONCRETE COVERAGE: THE FOLLOWING MINIMUM CLEAR DISTANCES BETWEEN REINFORCING STEEL AND FACE OF CONCRETE SHALL BE MAINTAINED UNLESS NOTED OTHERWISE. SLABS ON EARTH -------------------- CENTER OF SLAB CONCRETE BELOW GRADE, FORMED ------------------ 2" CONCRETE BELOW GRADE, UNFORMED (POURED AGAINST EARTH)3" 7. DOWELS FOR WALLS SHALL BE SAME SIZE AND SPACING AS THE WALL REINFORCEMENT AND SHALL LAP WITH THE WALL REFER AS NOTED ABOVE UNLESS NOTED OTHERWISE. 8. NO HEAT SHALL BE ALLOWED FOR BENDING OF REINFORCEMENT STEEL. 9. ANCHOR BOLTS, DOWELS, INSERTS, ETC., SHALL BE SECURELY TIED IN PLACE PRIOR TO THE POURING OF ANY CONCRETE OR GROUT. 10. ALL CONCRETE, 150 PCP F'C SMALL ATTAIN A MINIMUM COMPRESSIVE STRENGHT OF 2500 PSI AT 28 DAYS. 11. AGGREGATES SHALL BE NATURAL SAND AND ROCK COMFORMING TO ASTM C33 WITH PROVEN SHRINKAGE CHARACTERISTICS OF LESS THAN 0.05%. 12. CEMENT SHALL BE PORTLAND CEMENT COMFORMING TO ASTM C150, TYPE I OR II, LOW ALKALI. 13. PLACEMENT OF CONCRETE SHALL COMFORM TO AC1301, 14. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION A MINIMUM OF FIVE DAYS AFTER -PLACEMENT UNLESS OTHERWISE APPROVED BY THE ARCHITECT OR STRUCTURAL ENGINEER. 1. PROVIDE WATER RESISTANCE GYPSUM BACKING BOARD AS A BASE FOR TILE OR WALL PANELS. 2. SHOWERS SHALL BE FINISHED 70" ABOVE DRAIN WITH MATERIALS NOT ADVERSELY AFFECTED BY MOISTURE, SPECIFY MATERIALS, CLARIFY, SECS. 807.13 AND 2512. 3. ANTI -SCALDING SHOWER AND TUB -SHOWER VALVES REQUIRED CPC SEC. 420. 4. PROVIDE HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROM STREET. NUMBERS SHALL BE OF NON COMBUSTIBLE MATERIALS IN SPECIAL FIRE PROTECTION AREAS 0. C. ORD. NO. 5. WHERE TOP PLATES OR SOLE PLATES ARE CUT FOR PIPES, A METAL TIE MINIMUM . 058" THICK AND 1-1/2" WALL SHALL BE FASTENED TO EACH PLATE ACROSS AND TO EACH SIDE OF THE OPENING WITH NO LESS THAN 6-16D NAILS. CLARIFY SEC. 2320.11.7. 6. ALL BEAMS TO HAVE FULL WIDTH POST BEARING CLARIFY. 7. NOTE ON PLANS A STATEMENT THAT THE BUILDING COMPLIES WITH THE REQUIREMENTS OF TITLE 24, PART 6, SIGNED BY THE DESINGNER OR OWNER OF THE BUILDING AND BY THE DOCUMENTATION AUTHOR. 8. MAINTAINANCE INFORMATION, THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTAINANCE INFORMATION FOR ALL FEATURES ROUTINE MAINTAINANCE ACTIONS SHALL CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING, BY TITLE AND/ OR PUBLICATION NUMBER. THE OPERATIONS AND MAINTAINANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, COMPONENT, OR MANUFACTURE DEVICE. GENERAL NOTES WOOD FRAME 1. TOP PLATE OF ALL STUD WALL SHALL BE 2 PIECES THE SAME SIZE AS STUD SPLICES TO LAP 4'-0" MINIMUM AND BE NAILED WITH 12-16D MINIMUM EACH SIDE OF JOINT. 2. BOLT HOLES IN WOOD SHALL BE 1/32" OR 1/16" LARGER THAN THE NOMINAL BOLT DIAMETER, ALL BOLTS SHALL HAVE STANDARD OUT WASHERS UNDERHEAD AND NOT UNLESS NOTED OTHERWISE. 3. PROVIDE 2x SOLID BLOCKING BETWEEN JOIST AND RAFTERS AT ALL SUPPORTS, BLOCKING SHALL BE ONE PIECE AND THE FULL DEPTH OF THE JOIST OR RAFTER. 4. PROVIDE lx6 DIAGONAL LET -IN BRACING (AT APPROX. 45 DEGREES) EVERY 25'-0" MAXIMUM IN ALL STUD WALLS NOT PLYWOOD SHREADED BRACING SHALL RUN CONTINIOUS FROM SILL PLATE TO THE TOP. 5. PROVIDE FIRE STOPS AT ALL INTERSECTIONS OF STUD WALLS AT FLOOR, CEILING AND ROOF, FIRE STOPS SHALL BE 2x NOMINAL THICKNESS OF WOOD AND SHALL BE THE FULL WIDTH OF THE ENCLOSED SPACE. PLACE FIRE STOPS AT A MAXIMUM SPACING OF 8'-0" IN THE VERTICAL DIRECTION. PROVIDE 2 FIRE STOPS IN ALL FURRING SPACES VERTICAL DIRECTIONS AND HORIZONTAL, AND A MAXIMUM SPACING OF 8'-0" IN EACH DIRECTION AND THE SAME LINES AS FIRE STOPS. 6. ALL BOLTS SHALL BE RETIGHTENED PRIOR TO THE APPLICATION OF SHEATING, PLASTER, ETC. 7. ALL PLYWOOD SHALL COMFORM TO U.S. PRODUCT STANDARD PSI- 83 EACH SHEET OF PLYWOOD SHALL BE IDENTIFIED WITH THE APPROPIATE TRADEMARK OF THE PLYWOOD ASSOCIATION. ALL PLYWOOD SHALL BE CLASSIFIED AS EXPOSURE I, FOR PLYWOOD THICKNESS, GRADE, AND SPAN RATINGS (PANEL IDENTIFICATION INDEXES) SEE PANEL. 8. ALL WOOD BARING ON CONCRETE OR MASONRY SHALL BE PREASSURE TREATED DOUGLASS FIR. 9. STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, ETC., UNLESL SPECIFICALLY DETAILED. 10. ALL NAILS SHALL BE COMMON, NAILING SHALL BE PER CHAPTER 23 OF THE UNIFORM BUILDING CODE SEC. 2326 AND MIN. NAILING WITH TABLE 23-11131. 11. ALL STRUCTURAL LUMBER SHALL BE DOUGLASS FIR OF THE FOLLOWING GRADES, COMFORMING TO STANDARD GRADING RULES FOR WEST COAST LUMBER, No. 16 AIR DRY UNLESS OTHERWISE NOTED. GENERAL NOTES FOUNDATION 1. FOUNDATIONS SHALL BE THE SIZE AND TYPE AS INDICATED ON THE DRAWING. 2. ALL EXISTING FILL SOIL AND DYSTYRBED NATURAL SOIL ARE TO EXCAVATED AND REPLACE WITH PROPER LT COMPACTED FILL, ALL FILLING, BACKFILLING, AND RECOMPACTION, ETC.,IS TO BE ACCOMPLISHED ONLY UNDER THE SUPERVISION OF A SOIL ENGINEER. 3. ALL EXCAVATIONS ARE TO BE INSPECTED AND APPROVED BY A SOIL ENGINEER PRIOR TO THE PLACEMENT OF ANY FILL OR REINFORCING STEEL.. 4. FOOTINGS ARE TO BE CARRIED INTO FIRM UNDISTURBED NATURAL SOIL OR APPROVED COMPACT FILL A MINIMUM OF 12" BELOW ADJACENT GRADE FINISH FLOOR, WHICHEVER IS LOWER. 5. DESIGN BEARINGS PREASSURE IS 1000 PSF WITH 33% INCREASE FOR SISMIC OR WIND FOOTINGS. 6. DESIGN LATERAL BEARING PREASSURE IS 150 PSF/FT WITH A 33% INCREASE FOR SIESMIC OR WIND LOADING AND A 200% INCREASE FOR ISOLATED POLETYPE FOOTING. 7. DESIGN COEFFICIENT OF FRICTION IS 3 WITH A 33% INCREASE FOR SEISMIC OR WIND LOADING. 8. RAFTERS, JOIST, PLATES DOUGLAS FIR No.21250F. 9. BEAMS, STRINGERS AND HEADERS DOUGLAS FIR No.11350F. 10. POST AND TIMBERS DOUGLAS FIR No.11200F. 11. 2x6 JOIST AND RAFTERS DOUGLAS FIR No.21450F. 12. STUDS, BLOCKING AND SHIPPING DOUGLAS FIR STUD GRADE. 13. WOOD STUDS MAY BE NOTCHED TO A DEPTH OF 25% OF WIDTH MAXIMUM EXEPT INTERIOR NONBEARING STUDS WHICH MAY BE NOTCHED TO 40% OF WIDTH MAXI- MUM EXEPT INTERIOR NONBEARING STUDS AND DOUBLE BEARING (PROVIDEDE NO MORE THAN TWO SUCCESSIVE DOUBLE STUDS ARE BORED) WHICH MAY BE BOARED TO 80% OF WIDTH AS A CUT OR NOTHC IN NO CASE SHALL THE EDGE OF A ROARED HOLE BE NEARER THAN 3/8 INCHTO THE EDGE OF A BOARD. 14. PROVIDE DOUBLE JOIST UNDER PARTISIONS WHICH ARE PARALLEL TO THE JOIST. 15. PROVIDE SOLID FULL DEPTH BLOCKING UNDER PARTISIONS WHICH ARE PERPENDICULAR TO THE JOIST. GENERAL NOTES GENERAL 1. THE FOLLOWING NOTES AND TYPICAL DETAIL APPLY TO ALL DRAWINGS UNLESS NOTED OTHERWISE. 2. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUCTION WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. 3. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED, BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED SUBJECT TO REVIEW BY THE ARCHITECT OR STRUCTURAL ENGINEER. 4. PROVIDE OPENINGS AND SUPPORT FOR MECHANICAL EQUIPMENT DUCTS, PIPING, VENTS, ETC... AS REQUIRED. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL OPENINGS AND EQUIPMENT NOT SHOWN ON STRUCTURAL. ALL SUSPENDED EQUIP- MENT TO BE PROVIDED WITH APPROVED LATERAL OR SWAY BRACING. 5. ALL CONSTRUCTION AND WORKMANSHIP SHALL COMFORM TO THE DRAWINGS SPECIFICATIONS AND THE 2001 UNIFORM BUILDING CODE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT OR STRUCTURAL ENGINEER AND RESOLVED BEFORE PROCEEDING WITH THE WORK. 7. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE SHOWN. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION, THE CONTRACTOR SHALL DIRECT AND SUPERVISE THE WORK AND HE SHALL SOLELY BE RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, OBSERVATION VISITS TO THE SITE BY FIELD REPRESENTATIVES OF THE ARCHITECT OR STRUCTURAL ENGINEER. DO NOT INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OF THE OF THE PROCEDURES SUCH METHODS OF CONSTRUCTION. ANY SUPPORT SERVICES PERFORMED BY THE ARCHITECT OR STRUCTURAL ENGINEER DURING CONSTRUCTION SHALL BE DISTINGUISHED FROM CONTINIOUS AND DETAILED INSPECTION SERVICES WHICH ARE FURNISHED BY OTHERS. THESE SUPPORT SERVICES WHICH ARE FURNISHED BY THE ARCHITECT OR STRUCTURAL ENGINEER WHETHER OF MATERIAL WORK, AND WHETHER PERFORMED PRIOR TO, DURING OR AFTER COMPLETITION OF CONSTRUCTION, ARE SOLELY PERFORMED FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AND IN ACHIEVING COMFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS; BUT THEY DO NOT. SHEAR WALL SCHEDULE PER 2001 U.B.C. NOTES 1. INDICATES SILL PLATE NAILING OR ACHOR BOLTING FOR Two SIDE APPLICATION. 2. REFER TO SHEAR WALL NOTES ON PLANS FOR ADDITIONAL INFORMATION. 3. CONSTRUCTION OF PLYWOOD SHEAR WALL TOO BE WITH COMMON NAILS ONLY. 4. HOLDOWN BOLT HOLES AT EACH END OF THE PLYWOOD SHEAR WALL, SHALL HAVE A TOLERANCE OF NO MORE THAN 1/16" (INSPECTION REQUIRED). HOLD- DOWNS SHALL HE TIGHTENED JUST PRIOR TO LEVERING THE SHEAR WALL. ALL POSTS WITH HOLDOWNS OR UP LIFT STRAPS SHALL HAVE CONTINIOUS EDGE NAILING. 5. ALL ANCHOR BOLTS SHALL BE ATTACHED TO THE SILL PLATE WITH 2"x12"x3/16" SQUARE STEEL WASHER PLATES. 7. WHERE SHEAR PANELS ARE APPLIE ON BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 6 INCHES ON CENTER ON EITHER SIDE. PANEL JOINTS SHALL BE OFF SET TO FALL IN DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3-NOMINAL OR THICKER AND NAILS SHALL HE STAGGERED, SILL PLATES SHALL BE STRUCTURAL PANEL SHEATING SHALL BE STAGGERED. 8. ALL WOOD STRUCTURAL PANEL SHEATING SHALL BE C-D AND OTHER GRADES COVERED IN THE UNIFORM BUILDING CODE AND RD'S 4W51 23- PLEW140 lL__ ___ ­ F STAGGERED # DESCRIPTION LOAD SILL NAILING FDN ANCHO RANGE DRAWN BY:��' DANIEL CaNTRERAS 2060 NEWPORT BLVD. # 15 COSTA MESA, CA 92627 949-548-4057 CHECK BY: DATE: 12/13/04 SCALE: 1 j4>,`1>_O, SHEET NO: � 5 of 5