HomeMy WebLinkAbout10147618.pdfS'll-RUCTURAL MATERIAL NOTES CONCRETE LUMBER 1, ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR 1. ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR CONFORMING TO DIVISION 23 (2001 C B.C.) WEIGHT HARD ROCK TYPE (150 */CU. FT.). AGGREGATES SMALL BE NATURAL SAND AND ROCK CONFORMING TO ASTM C-33 WITH PROVEN 2. RAFTER. BEAMS, PURLINS SMALL BE DOUGLAS FIR NO. UNLESS SHRINKAGE CHARACTERISTICS OF LESS THAN 0.05 X OTHERWISE NOTED = 2. READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE GRADE WITH ASTM C-94. PLACEMENT OF CONCRETE SHALL CONFORM TO 3. JOIST, PURLINS 2" TO 4" WIDE, 6°" & DEEPER NOA AC1301, BEAMS, PURLINS OVER 4" WIDE NO.I. 3. CEMENT FOR ALL CONCRETE SHALL BE PORTLAND CEMENT TYPE V, LEDGRi►A1S 2'. TO 4° WIDE. 6" & DEEPER NO.1 E OR ILOW ALKALL CONFORMING TO ASTM C-150, SEUDRS STUDS 2" x 4" OR 3" x 4"` STL#3S STUDS 4, MINIMUM COMPRESSIVE STRENGTH OF CONCRETE: AT AGE OF STUDS 2" x 6" NOA 28 DAYS FOR: POSTS 5" x 5" AND LARGER NOA SILLS. PLATES AND BLOCKING N0.2 FOOTINGS 2500 PSI SLAB ON {MADE` 2500 PSI 4. SILLS AND PLATES IS CONTACT WITH CONCRETE OR MASONRY AND SIDE WALKS 2000 PSI WITHIN 48' OF GROUND SHALL BE PRESSURE TRESTED DOUGLAS FIR (PTOF). SLLS SHALL BE BOLTED TO THE FOUNDATION WITH 5/8" S. MAXIMUM SLUMP SHALL NOT EXCEED 4" DIAMETER x 10" BOLTS AT 48`° ON CENTER, 12" MINIMUM FROM 6. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A ENDS OR 2 BOLTS MINIMUM PER PIECE. UNLESS NOTED OTHERWISE_ MINIMUM OF 5 DAYS AFTER PLACEMENT, ALTERNATIVE METHODS 5, STUB WALLS ABUTTING A CONCRETE OR MASONRY WALL SHALL BE WILL BE APPROVED? IF SATISFACTORY PERFORMANCE CAN BE BOLTED TO THE WALL WITH 5/8" ANCHOR BOLTS AT 24" ON CENTER. ASSURED, 6. ALL NON BEAMING STUD WALLS SHALL BE 2 x STUDS AT 16 O.C. 7, ALL REINFORCING STEEL, ANCHOR BOLTS. DOWELS AND OTHER WITH ` " GYP. BOARD EACH SIDE. UNLESS OTHERWISE NOTED. INSERTS SHALL BE SECURELY FASTENED IN THE FORMS BEFORE 7. ALL STUD WALLS SHALL HAVE FULL HEIGHT I 6 DIAGONAL CONCRETE IS POURED, ADEQUATE CLEANOUTS SHALL BE PROVIDED LET -IN BRACES AT ENDS AT INTERVALS NOT EXCEEDING 25 FT, IN BOTTOM OF CONCRETE FORMS FOR PROPER CLEANOUT ANO INSPECTION. O.C. UNLESS OTHERWISE NOTED ON PLANS. BRACES SMALL COVER A MINIMUM OF SIX STUD SPACES. 8. VIBRATION OF CONCRETE SHALL BE IN ACCORDANCE WITH THE I 8° C NAILS SHALL BE USED. GENERAL PROVISIONS OUTLINED IN PORTLAND CEMENT ASSOCIATION SPECIFICATIONS ST-26. 9. FIRE BLOCKING 2 x IV a" THICK, SHALL BE PLACED IN STUD 9. EXPOSED CORNERS OF COLUMNS. BEAM, WALL. ETC, SHALL WALLS AT CEILING AND FLOOR LEVELS. AT EACH 10-HEIGHT OF STUDS, AND BETWEEN STAIR STRINGERS AT SUPPORTS, BE FORMED WITH R'4 ° CHAMFERS 'UNLESS METALED OTHERWISE. 10. CONCRETE CONTRACTOR SHALL SUBMIT PROPOSED CONCRETE 10. JOISTS SHALL BE BLOCKED AT SUPPORTS AND BRIDGED OR BLOCKED AT INTERVALS OF $' WHERE JOISTS ARE 2 x 12 OR DEEPER, DESIGN MIX TO THE ARCHITECT AND ENGINEER OF RECORD, PRIOR TO STARTING THE 'FORK, It MAXIMUM UNSUPPORTED HEIGHT FOR NON -BEARING PARTITION SHALL 11„ NO WATER SHALL BE ADDED TO CONCRETE WITH TEMPERATURE 2 x 4 0 IS" O.C. UP TO 14'-0" IN EXCESS OF 95°F. 2 x 6 0 16" D.C. UP TO 20'-0" 2 x 8 0 16" Q.C. UP TO 26'-0' 12. WIRE MESH LAP (END & SIDE)SHALL BE ONE FULL MESH -2. 12. PROVIDE DOUBLE JOISTS UNDER PARALLEL BEARING PARTITION WALLS. 13. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM "W' AND A M !&" LARGER THAN THE BOLT DIAMETER. PLYWOOD 1. PLYWOOD SHEETS SHALL BE COX CONFORMING TO PS 1-95 AND SHALL BE STAMPED WITH THE ORPA GRADE OF THE AMERICAN REINFORCING STEEL PLYWOOD ASSOCIATION. UNLESS NOTED OTHERWISE ON THE PLANS. 2. EACH SHEET SHALL HAVE A MINIMUM AREA OF 8 SO. FT, WITH A 1., REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED MINIMUM DIMENSION OF 2 FEET. BARS AS FOLLOWS 3. SEE FRAMING PLAN FOR DIAPHRAGM NAILING SCHEDULE. NAILING FOOTING. SLAB ON GRADE. SHALL BE INSPECTED AND APPROVED BEFORE COVERING. MASONRY, AND BENT DOWELS, TIES °3 BAR AND SMALLER ASTM A-615 GRADE 40 -4 BAR AND LARGER ASTM A-615 GRADE 60 2. DEFORMATION OF REINFORCING SHALL BE IN ACCORDANCE WITH ASTM A-305 AND BENDING IN ACCORDANCE WITH AC1318-95. FOUNDATION NOTES 3ASNOET£OTHERWISE) COVERR REINFORCING REBAR FOR (EX NOTED 1, FOUNDATION HAS BEEN DESIGNED ASSUMING MIWMUM ALLOWABLE EXPOSED WEATHER OR EARTH 1`I TO SON. BEARING PRESSURE PER 2001 CALIFORNIA BUILDING CODE SHALL XPOSED WEATHER EXP E EXPOSED TO EARTH 26 BE AS FOLLOWS: *° PILASTER. BEAM & COLUMN TIES I fg CONTWOUS FOOTING 1000 P.S.F. FORMED FOOTING AND WALL EXPOSED TO EARTH 2' ISOLATED FOOTING * 1000 P.S.F. UNFORMED FOOTING AND WALL EXPOSED TO EARTH 31, SLAB ON GRADE 2" 2. ALL FOOTINGS SHALL BE FOUNDED ON OR BELOW FIRM 4. SPLICE IN CONCRETE UNDISTURBED NATURAL SOIL, OR APPROVED COMPACTED FILL AND MINIMUM OF 36 BAR DIAMETER OR 12" WHICHEVER IS GREATER, ADJACENT FINISH GRADE UNLESS NOTED OTHERWISE. 3. ALL FOOTING SHALL BE CENTERED ON PILASTER AND/OR WALL AND 5. WELDED WIRE FABRIC SHALL 'CONFORM TO ASTM A-185 AND 1-82. COLUMN UNLESS OTHERWISE NOTED. 6. ALL DETAILING OF REINFORCING SHALL CONFORM TO THE REQUIREMENTS 4. FINISH FLOOR (F.F,) EXCAVATION SHALL BE AS NOTED ON GRADING OF AC1318-95. PLANS, 7„ ALL REINFORCING STEEL. DOWELS, ANCHOR BOLTS, INSERTS. ETC. 5. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION SHALL BE SECURED XV PLACE PRIOR TO PLACING ANY CONCRETE OR GROUT. PROCEDURES INCLUDING LAGGING. SHORING AND PROTECTION OF ANY ADJACENT PROPERTY. STRUCTURES. STREETS AND UTILITIES IN 8. ALL REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY OF ASTM A-615 GRADE 60. ORDINANCES. 9. ALL REINFORCING BAR BENDS SHALL BE MADE COLD, 6. ALL FOOTINGS SHALL BE FORMED TO MEET SIZES INDICATED ON 10. ALL REINFORCING BAITS SHALL BE FREE FROM GREASE, RUST, MILL DRAWINGS. DETAILS, AND/OR SCHEDULES. SCALE OR ANY OTHER FOREIGN MATERIAL WINCH MAY AFFECT THE 7. ALL FOOTINS AND PIERS SHALL BE CENTERED UNDER THE BUILDING BARS ABILITY TO BOND TO THE MORTAR. COLUMNS, (U.N.O.) It. REINFORCEMENT THAT IS PARTIALLY 'EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT AS SPECIFICALLY DETAILED IN THESE S. ALL EXISTM UTILITIES THAT INTERFERE WITH THE STRUCTURAL FOUNDATIONS ORA"4GS OR WITHOUT THE WIITTEN APPROVAL OF THE ENOWER OF RECORD, SHALL BE REMOVED AND RELOCATED. 12. ALL REINFORCING STEEL SHALL BE PROVIDED AT ALL POUR JOINTS 9. ALL PIPES. DUCTS AND CONDUITS WITHIN THE SPHERE OF INFLUENCE OF ON THE DRAWINGS. WHERE LAP AND/OR SPLICE LOCATIONS ARE THE FOOTING. tTHE PRESSURE ZONE. EXTENDING BELOW THE FOOTING. NOT SPECIFICALLY INDICATED, PROVIDE CLASS "C" SPLICE PER BASED ON A 2 HORIZONTAL TO 1 VERTICAL SLOPED, SHALL BE SLEEVED SCHEDULE. ALL SPLICE LOCATIONS SHALL BE CLEARLY SHOWN ON THROUGH' CONCRETE CAST -II -PLACE AT THE FOUNDATION POUR. SHOP DRAWINGS AND APPROVED BY ENGINEER OF RECORD BEFORE 10. FOUNDATION MAY BE SUBJECT TO STRUCTURAL REVISION IN THE FIELD FABRICATION, DUE TO POSSIBLE VARYING SUBSURFACE CONDITIONS. 13. PLACING TOLERANCES AND BAR SUPPORTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR REINFORCING CONCRETE CONSTRUCTION, BY WCRSI, 14. CLEARANCE BETWEEN PARALLEL BARS IN A LAYER SHALL NOT BE FOUNDATION PLATES/SILLS E. LESS THAN SECOND LAYER SHALL AR DIRENOR lu CTLY AGGREGATE BARS IN FIRST LAYER. MIN. DISTANCE BETWEEN LAYERS - 1". 1, FOUNDATION PLATES OR SILLS SHALL BE BOLTED TO THE FOUNDATION OR FOUNDATION WALL WITH NOT LESS THAN W' DNA. STEEL BOLTS EMBEDDED AT LEAST 7"INTO THE CONCRETE OR MASONRY AND SPACED NOT MORE THAN 6*-O" APRART, THERE SHALL BE A MINIMUM OF (2) BOLTS PER PIECE WITH ONE BOLT LOCATED WITH 12" OF EACH END OF EACH PIECE.A PROPERLY SIZED NUT AND WASHER SHALL BE TIGHTENED ON EACH BOLT TO THE PLATE. FOUNDATION PLATES AM SILL SHALL BE THE KIN? OF WOOD SPECIFIED N SECTION 2306:4 OF THE 2001 C.B.C. i' !! i'L',1 11 IfI a. i # 2.. VERIFY ALL DIMENSIONS,00 NOT SCALE DRAWINGS. 3. IT SHALL BE THE RESPONSABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON i TO COMMENCING WORK AND IS TOi- ONCE IE UPON DISCOVERY OF i OR CONFLICTS THE DR'" PREPARATION OF 1I SECTION: ROOTS BE REMOVED FROM i DEPTH OF AT LEAST 12 INCHES BELOW THE SURFACE OF *# !I TO BE OCCUPIED BY THE BUILDING) 5. ALL NAILING TO COMPLY TYPE OF • r #CCUPANCY GROUP INSULATION EXT WALLS R-13 ATTIC R-30 SUBFLOOR R-19 FENESTRATION * FENESTRATION - U-FACTOR-0.40 MAX SHGC- 0.35 MAX A/C EFFICIENCY N/A RADIANTOR EOUAL TO M INSTALLED.05 TO, COVER!i 1I GABLE *ALTERNATE FOR TXV OR/OR SEAL .DUCTS . ., $ 'y LANDSCAPE F <5. 7 d r to CNI ^ x m -.a .y u REMOVE (E, CONC.-WALKWAY,--=-= AND k�R�iVNC1D PER, CITY .,STANDARDS -- � LANDSCAPE 11 S�- I:TAC61i PEE 4 0 i' ♦ ♦, i ♦ it GARAGEEXISTING ° PROPOSED ADDITION TOTALw TOTAL • #N 2597 ° ft LOT COVERAGE 37.17 PO V Im PLANNING V ffl% b), {'kit y] I � r� I�Yv..A'.'cHX � F 1 TPH 33�d/� +�R,+ CcN� L' � U C^Y� f°c. rnRi ' ON `j, @","..ubu,n'c�3 wr„aa ,,,... wE, t.».ie .ma'�zr 'd ?4, ,.D 3 gg:.be4 $ E:'i & $ ffi9t 59 L 11 dDs; €' s Rd ,t Vic, � �t.''�d� .� Iw�3 t�-n �s��.(,� u'-�Q� °c�`sh'ti�;3 w`��' ,t. €, Cited of Santa Ana. hs, c taruf hIS 1_n &jid specifications SHALL NOT s hdd III permit PCs jDr0v,1 C' :h a violation Of. BII rov%1 D� of ANY CRYrd'in nce or Stato I-XV14. I Actorled, By R x CC 3 2 U D 0 z < FH17I4{ 835 1585 I Fx 714 ! 835 1428 2017 W. ALCO AVE. SANTA ANA O CALIFORNIA 92703 Z AADRAFTING@MSN,COM REVISIONS w a.a. A 0 tL a. a w w % M z 0 h U z SITE: a w IL 0 II; tt w Cr 3 Q w ir h z w R 0 R: k'NA "014� {714L542 3275 J�ESCRIFJION: '833 T��■RY TION: 3 BEDROOMS, BATHROOMS, N E PANS ON} DRAWN: AL. CHECKED- ' DATE: JOB NO: JUN-13-04 SHEET NUMBER: A-1 P*REPAFRED BY- b 3m LEGEND SMOKE QE BATTERY BACK-UP 110@ BATTER OPERATED SMOKE DETECTOR NOTEr 9V@ TECTOR Ci, RECESSED CEILING LIGHT PROVIDE SMOKE DETECTORS IN EACH BEDROOM AND CORRIDOR OR HALLWAY .ACCESSING SUCH BEDROOMS PER SECTION 310.9.1.3 & 310.9.1.4 RECESSED MINI LIGHT 2001 CBC. SEE NOTE "V BELOW FOR S.O IN WALL MOUNTED LIGHT EXISTING BEDROOMS -}- CEILING LIGHT 1/2 HOT 110V 0 -12" U.N.O. 110V OUTLET FUEL GAS 220V OUTLET GFI GROUND FAULT INTERRUPTOR SWITCH 3 3-WAY SWITCH HOSE 818 HOSE BIBBS TO HAVE A NON -REMOVABLE AIR DIFFUSER GRILLE BACK -FLOW PREVENTER OR W ATMOSPHERIC VACUUM BREAKER.H A LISTED FL FLUORESCENT MECHANICAL FAN. MI 5 AIR CHANGES PER HR. +---+ FLUORESCENT LIGHT 1--� LOG LIGHTER. PLUMB FOR ICE MAKER TELEPHONE JACK AFI RECEPTACLE OUTLETS SUPPLIED BY BRANCH CIRCUITS PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER FL FLUORESCENT AS REQUIRED 4 2"-1" i 11"- 4 *' 0 FLOOR PLAN NOTES 1 2X6 PLUMBING WALL / FAT WALL 2 RECESSED MEDICINE CABINET 3 TOILET. 1.6 GAL PER FLUSH SEE OWNER SPECS 4 F.G.TUB- SHWR. W/ GLASS ENCLOSURE DOORS & PANELS MUST BE LABELED CATEGORY II NET AREA OF SHOWER SHALL BE NO LESS THAN 1024 SO. IN. OF FLOOR AREA, & ENCOMPASS 30" DIA. CIRCLE. WALL COVERING TO BE TILE W/ WATER PROOF BACKING TO EXTEND UP TO WALLS MIN. 70" ABOVE DRAIN. MATERIALS OTHER THAN STRUCTURAL ELEMENTS SHALL BE MOISTURE RESISTANT 5 LAVATORY SINK. SEE OWNER SPECS 6. SHELF & POLE 7 ATTIC ACCESS (22"X30") 8 PROVIDE R-13 INSULATION AT ALL EXTERIOR WALLS PER TITLE' 24 9 CABINET. PER OWNER 10 LINE OF SOFFIT ABOVE 11 40 K BTU NATURAL GAS WALL HEATER. PROVIDE/GAS FUEL 12 UNDERCOUNTER DISHWASHER. 110V OUTLET 13 30" RANGE OVEN W/ HOOD AND VENT TO OUTSIDE. PROVIDE 110V OUTLET AND FUEL GAS. 14 36" REFRI. SPACE PROVIDE 110V OUTLET 15 PANTRY 16 DOUBLE SINK W/ GARBAGE DISPOSAL '.. 2" 11"-0"" -� 38"- 4. NOTES­ 0. EVERY BEDROOM SHALL HAVE A OPERABLE ESCAPE WINDOW WITH A MIN. OPENABLE AREA OF 5.7 SO. FT. AND A 'MIN.CLEAR HEIGHT OF 24 INCH AND WIDTH OF 20 INCH, THE SILL HEIGHT NOT OVER 44 INCHES ABOVE THE FLOOR. b. ALL GLAZING MIN. 3Y$" THICK AN A STRENGHT "B" OR BETTER TO COMPLY WITH SECTIONS 2403, 2404 & 2406 CBC. c- HEATER PER NOTE 11 TO MAINTAIN A ROOM TEMPERATURE OF 700 AT A POINT OF 3 .FT. ABOVE THE FLOOR IN NEW HABITABLE ROOMS. d. EXIT - EACH EXIT DOOR MAY BE PROVIDED WITH A NIGHT LATCH., DEAD BOLT OR SECURITY CHAIN" PROVIDED SUCH DEVICES ARE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR TOOL OR SPECIAL KNOWLEDGE OR EFFORT AND MOUNTED AT A HEIGHT NOT TO EXCEED 48 INCHES ABOVE THE FINISHED FLOOR. e. WATER CLOSETS TO USE NO MORE THAN 1.6 GALLONS PER FLUSH. f. GLAZED WARDROPE DOORS SHALL MEET THE IMPACT TEST REQUIREMENTS OF UBC ST. 24-2, PART II . LAMINATED GLASS DUST ALSO MEET THE BOIL TEST REQUIREMENTS Of UBC STD. 24-2" PART II. g. LIGHT AND VENTILATION PER CBC SECTION 1202. MIN. OF 15 CFM OF OUTSIDE AIR PER OCCUPANT IS REQUIRED FOR VENTILATION RIM 1 NEW WALLS EXISTING WALLS TO REMAIN I--. — a EXISTING WALLS TO REMOVE ! • b lFilviollis•011 I Imla- r__ PEI firli� IT o D 14 _c -G-i- Ec, 7LL, rL — - e r H 714 835 1585 1 Fx 714 I 835 1428 2017 W. ALCO AVE. SANTA ANA I CALIFORNIA 92705 Z AADRAFTINGOMSN. COM w REVISIONS 0 a. A - i a it 0 c� Q a z 0 0 0 Ci a f J III vj< z C III ¢ D a w a r z w C3 OWNER: 0 w BLANCA FREY DRAWN: , • AL CHECKED: DATE: µ JuN-13-04 JOB NO: SHEET NUMBER:V A-2 PPEPAIED Br: MAL. ASPHALT SHINGLES TO MATCH EXISTING A STUCCO EAVEW TO MATCH EXISTING [Kim llr� F-A K * Iwo 21*4 6*11 Oil NEW WINDOWS AND TRIMS --- TO MATCH EXISTING IN MATERIAL \l'—FOUNDATION VENTS AND OPERATION TYPE TO MATCH EXISTING WOOD LOUVERED ATTIC VENT TO MATCH EXISTING TYP. PERNWilff X%T*047m, 111f4 PROP'D i EXIST'G warQ&A EXIST' I PROPT we ` A 9 K#_ R — — — .......,®. I — — — — SOUTH FOUNDATION VENTS TO MATCH EXISTING I Ar EAST (Front) ASPHALT SHINGLES TO MATCH EXISTING STUCCO EAVE TO MATCH EXISTING STUCCO EXTERIOR TO MATCH EXISTG PI,• 1X SILL TYPICAL WINDOW DETAIL UA ALL WOOD SASH IAL I SHINGLE lNG TO MATCH rING W/ G.I. :DRIP PAINTED MATCH EXIST'G ASPHALT SHINGLE STUCCO FINISH ) MATCH (ISTING) EAVE DETAIL Og nflff:15? ALL NEW EXTERIOR FINISHES, WINDOWS, TRIMS, ROOFING. EAVES ETC., SHALL MATCH EXISTING IN TYPE, COLOR, MATERIAL AN TEXTUR NO SECURITY BARS WILL BE INSTALL 0 ON WINDOWS OR DOORS OF THE NEW ADDITION y ir 0 P Cl 11 z < PH 7141 8351 1585 1 FX 714 / 835 1428 2017 W. ALCM AVE. SANTA ANA CALIFORNIA 92703 Z AADRAFTINGOMSN-COM REVISIONS w 0 0 Ir a. 0 x 0 IL w z 0 D z SITE: x t1i 0. 0 cc (L IC w z 0 to w vj< 0 tt%Z w vi 0I_ < �F 0 z OWNER: 0., w BLANCA FREY 0 w T Z (714) 542 3275 fL JoB DEscRipTto - 833 SQ FT I -STORY ADDITION: 0 Is 0) ui (3 BEDRO 2 BATHROQ0 S, z Kill- 0- EXPAN w to in 0 z 0 EXTERI 0 ELEVATI co rl W, z DRAWN: AL ,CHECKED. DATE: JUN-13-04 JOB NO: SHEET NUMBER: A 3 9 2 to 00 I Ir 00 Fil L=S'-4- L -- IV-&" L -- l'-O T_ 4X6 WOR 4X6 WOR U QR w NEW BEDR004 BEDROOM n A= 4X4 u it, -,a _.iol .1 �1.1 - - . i — 4 KING T44, 4X(v - - - - - - - - - - - ATTIC ACCESS jjft__A�4 NEyr X-1 B ATH L 0 k*14 ,_ A35 Is TOP fzLT. (E) DROOM 2XI EEFIER k :E TIP CALIFORNIA FRAMIWj AT 14ATCWING iml 4Xs Ha L=3*- 1 1 j­ W Aa5 ul 0 1 TOP PLT. FOUNDATION NOTES 1. FLOOR SHEATHING - USE )tA­ STRUCTURAL If C-D OR C-C PLYWOOD MINIMUM PANEL INDEX NUMBER (40/20) 4G. W/ 10d NAILS 0 6" O.C. SUPPORTED EDGES AND 10d 0 10" O.C. IN THE FIELD (UNBLOCKED FACE GRAIN OF PLYWOOD SHALL BE PERP. TO SUPPORTS 2. EXISITNG 12"X12" CONC. FTNG .3. CONCRETE FOOTING. 02" W X 12" D W/ (1) 04 TOP & BOTTOM MIN, CONC. CURB REBAR DOWELL 6" INTO EXISTING FOOPG TOP & BOT W/ SIMP, 'EPDXY" 6. 12"X12" G.ISCREENED FOUNDATION VENT 7, 18"X 24" G.I. SCREENDED FOUNDATION ACCESS 8, GIRDER POCKET OR HANGER 9. 18"X24" CRAWL SPACE 10. EXIST'G CONCRETE LANDING NOTES - a. -VERIFY HRDWR.LOCATION Wl FLR.PLAN b. -HOLDOWN ANCHORS MUST BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. c. -SURFACE WATER WILL DRAIN AWAY FROM BUILD*G. d. HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS,AND HOLD-DOWNS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. e. ALL INTERIOR NON -BEARING WALtS WITH SHOT PINS. RANSET *3348, OR EQUIVALENT. UNLESS OTHERWISE NOTED. f. DIA A. B. MAY, BE REPLACED BY THREADED RODS W/ 5Y4" EMBED. WITH CIA -GEL 7000 EPDXY SYSTEM 0. ER. 4846. (OR EQUIVALENT) 4 cBC, AT THE SAME SPACING. PER 2320.11. SHEAR PANEL C-D. C-C PLYW'D BLKO. W/ 10d 0 6" O.C. E.N. & 12" O.C. F.N. 2X P.T.D.F. SILL CONNECTION W/ x DIA. A.B. 0 32" O.C. THREADED RODS CIA -GEL 7000 EPDXY OR EQUAL flCBO 4846) AT EXIST'G FOUNDATION.. — TOP, ANCHORAGE WITH A-35 0 16" O.C. FRAMING NOTES PROVOE ROOF RADIANT BARRIER 1. ROOF SHEATHING-, Z PER TITLE 24 AT ROOF SHEATHINa 1/2" CDX PLYWOOD (32116) OR OS8. UNBLOCKED DIAPHRAGM. W/ NAILING- 8d 0 6" O.C. SUPPORTED ENDS & BOUNDARY 8d 0 12 O.C. FIELD. USE (8) 16d 0 TOP PLT. CHORD SPLICE W/ ST6224 (USE lX6 SOLID SHEATHING OR A-C GRADE PLYWOOD AT EAVES & OVERHANG) 2. PROVIDE 4X POST AT EACH END OF 4XIO OR LARGER MEMBERS,DOUBLE STUDS FOR 4X8 SINGLE STUD FOR 4X6 OR SMALLER MEMBERS WH DOUBLE 2x SOLE PLATES ARE USED.PROVIDE PROGRESSIVE NAILING. 4. ALL NAILS ARE COMMON NAILS. 5. ALL STUDS a 16" O.C.MAXIMUM. 6. ALL LAG BOLTS (LB) TO BE 8" LONG INSTALLED WITH PILOT HOLE AND WRENCH. 7. FRAMING MEMBERS OR BLOCKING SHALL BE PROVIDED AT ALL EDGES OF ALL PLYW*D SHEETS IN SHEAR WALL. 8. ALL -PLYWOOD PANELS SHALL BE MANUFACTURED USING EXTERIOR GLUE. 9, 2 LAYERS OF 15* FELT SHALL BE USED AT ALL UCCO APPLIED OVER PLYWOOD. 801 10. SEE TAILS Q)w FOR ALLOWED BORING AND NOTCHING OF STUDS AND JOISTS ii. SEE DET FOR TYP. EXTERIOR WALL FRAMING 12. MIN. 2X6 STUDS AT PLUMBING WALLS. 13. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS 14. DOUBLE JOIST ARE REQUIRED UNDER PARALLEL BEARING PARTITIONS 11 1 1 1 CALIFORNIA FRAMING SOFFIT FRAMING SHELF k INTERIOR BEARING WALL PfIEPAF�ED 8r: 'I I - 1, '�A 0 D C z :—4 H 71 835 1585 T FX 714 835 1428 2017 W. ALco AvEi. SANTA ANA CALIFORNIA 99703 Z AADRAFTINGOMSN.COM REVISIONS w 0 0 cc a. 0 F_ 0 ti D Uk SITE: m: LLI CL rc v i z Ju Ll viz o< it L U) > C\IVJ vi tl OWNER: BLANCA FREY tl E (714) 542 3275 Jon DESCRIPTION: 833 SO FT I -STORY ADD[N: (3 BEDR," 2 BATH 0 R%MS, 8i KITCHEN u L EXPAN 1. op, STRUCTURAL PLANS rT DRAWN: AL CHECKED: DATE: JuN-13-04 JOB NO: SHEET NUMBER: S-1 PrEPAqED Br: (2 ROWS) i ------ Ar-m 0 r AM 101 1. 'SIMP' EPDXY -TIE TO SHEAR PANEL D RFB 05X8 W/5" MIN. PER PLAN 6 EMBEDMENT DEPTH co 2 TO CONC. AT 4 '/2" MIN. FROM END, 12 " MIN. FROM EDGE. SPACED PER 7 6 :c FOUNDATION PLAN 11 SSTS C3 0. uj w 2. EXISTING CONC. FOOTING ANCHOR- 0 4 m 0 1. 2X OR 3X STUDS PER PLAN m S.W_ SCHEDULE 6 3 END RIM .1ST. BLK'G 2 0 4 12 2. E.N. 4 4. 16" LONG 2X SHIM OR 3. B.N. 2x 2 BLOCK 4. S.N. 5. PLYD SHT'G PER PLAN 2 NOTES^ I- (E) ROOF SHT'G 0/ 2X ROOF RFTR. 2- 2X RAFTERS NAILED TOGETHER 10 7 12 6 -17 16 1 A. DRILL HOLES PER MANUF. SPECS. 1 1 1-1 I-LY4" MIN 8. A307 THKATED RODS Wi SIMPSON 2- E.N. 7 2- 2X TOP PLT. SET EPDXY ICW *5279 3- 2X BLOCKING (ALT.) 2 L J 4- 2X CONT. 'SHAPED' W/ 16d @ <- ----o 8, SIMP. A35 0 16" O.C. 6" D.C. TO BLOCK- OR- WITH 9. SIMP A35F 0 16" O.C. 2- 16d NAILS TO EACH RAFTER 11 IN LIEU OF 2X BLOCKING. 10, CL*G JST, PER PLAN 5- 2X RAFTER 'CALIFORNIN FRAMED 11. WALL FINISH PER PLAN I . z '78 0'' -Y4 1 " FRM EDGE < PH1714 35Is 8 s I FX 714 / 835 1428 2017 W. ALco AvE. SANTA ANA CALIFORNIA 9270-A Z AADRAFTINGOMSN.COM 3 w REVISIONS ILI 0 0 a. F-A 0 0- LTVVU �Zn VJ r-r-M rLfM'A 12. SOLID BLK'G 0 A 'CALIFORNIA' FRAMED SHEAR TRANSFER a. 17 13 9 A.B.AT EXISTING FTN'G HOLDOWN ROOF 5 2 5 1 w 3� 4 2 2X R.R. 3 5 2 o 4 4 z 0 _- + + \ 2X6 CONT. (LET -IN) 6 PURLIN W/ (2) 16d 7 AT EACH BRACE 6 + + 7 z SITE: + 2X4 BRACES 0 9 48" O.C. W/ iL (3) 16d TO RAFTER 9 1- 2X STUD WALL PER PLAN 0 6 Of 2- 2X4 PLT. Q. 3- SHEAR WALL WHERE OCCURS 1- ROOF SHT'G 0/ 2X ROOF RFTR. 4- *2X BLK'G OR 0 PER PLANOX6 STARTER BOARD 9 RIM JST. -SHIPLAP- AT EXPOSED EAVES) z Al h < 2- B.N. 5- PLAN SHEAT*G PER �1_1 I- ST2115 0 48" O.C. IN PLAN 0/ 2X FLR. JST, z LIEU OF 2X4 TIES 3- (5)- 16d 0 RFTR. TIE b, PER PLAN W/ R-19 INS. 0 4- 2X BLK'G W/ A-35 0 6- G.I. MUDSCREED AT EXT. WALLS 2-2X TOP PLT. 2- B.N. 16" O.C_ U.N,.O. 0: 3- 2X RIDGE BOARD 7- A-35 0 16" O.C. 0 2X C. J. 5- 2X CEILING JST. 8- 2X4 P.T. D.F MUDSILL W/ A.B. it 2X STUDS--,,4- PLYW*D ROOF SHEATHING PER PLAN PER PLAN PER PLAN W/ 2V2"X2V­ X w vj< '/A" THK.PLATE WASHEA z 5- ROOF RAFTERS PER PLAN 6- DSL TOP PLATE PER PLAN .3% 6" 0"L 3: 6- 2X4 TIES @ 48" O.C. 7- 2X STUDS 0 16" D.C. SEE SHEAR WALL SCHED. , w­_ 9- CONCRETE FTN'G PER PLAN 0 7- 3- 16d TYP. OR WD.BM. PER PLAN FOR SHEAR TRANSFER 0 12" MIN 10- M04 REBAR TOP & SHEAR WALLS BOT. d w 8- CJ / TIE PER PLAN W/ 4- 16d 8- SHEAR WALL PER PLAN z TO RAFTER WHERE OCCURS 0 (1) ILI U) w 10 SHEAR TRANSFER I-_ viz 18 PURLIN 14 RIDGE 6 EXTERIOR FOOTING :c AT 0 1 Q OUTER 1/3 MIDDLE 1/3 , OUTER 1/3 z OF SPAN OF SPAN OF SPAN ONLY SHR. WALL 1 2 4'- 0" MIN. LAP (2)16d STUD ATTOP OR SOT NO NOTCHES AT TOP OR SOT WHERE OCCURS ALLOWED U.N.O. I aL (8) 16d 0 MIN. & S.N. 2 • LAP TOP PLT. 16d 0 16" O.C. 0 EXISTING EXISTING vi 0 STUD MAX 0.0 OR NE W 4 E.N. 5 �OR NEW 0 4 8 PER PLAN PER PLAN z z z 4X HDR. N< MIN. PROVIDE 1X6 LET -IN BRAC*G (IF NO SHEAR WALLS OCCUR) 0 60 vi MAX, 0 450 MIN. W/ 16d 0 24" (3) 8d EA. END & EA, OUTER 1/3 MIDDLE 1/3 OUTER 1/3 NOTCHING < NAIL FACE (3) 16d E.N. STUD BRACE EA. OF SPAN OF SPAN OF SPAN ONLY 2 z 8 6 I T -TYP. CORNER 0 25'O.C. MAX. AT TOP OR SOT NO NOTCHES AT TOP OR SOT 5 7 7 2X TRIM1*R & ALLOWED U.N.O. 9 1- 2X STUD WALL WHERE OCCURS (2) 16d E.N. PROVIDE 2X FIRE KING STUDS PER PLAN w TO 2X SILL BLOCK WHERE WALLS 2- 2X4 PLT. cc TYP. 3 CL'G & SOFFIT LINES C4 3- SHEAR WALL WHERE OCCURS Cr JAMS EXCEED 10'H. & AT ALL 1- ROOF SHT'G 0/ 2X ROOF RFTR. PER PLAN w c*4 F.G. 4- 2X BLK'G OR FLOOR JST 1_2X STUDS z a 161, O.C. 2- 2X FASCIA BD. W/ STUCCO 5- PLYWD SHEAT`G PER 0 0�r PLAN 0/ 2X FLR. JST. 2X P.T.D.F. SILL PLT. OVER TO MATCH EXISTING PER PLAN W/ R-19 INS. z (2) 10d T.N. 0 W/%" DIA. ANCHOR 3- B.N. go w EA. SIDE STUD I z 41 6- 2X BLK'G 0 16 O.C. TO PLT. BOLTS W/ 7" EMBED -T 6 el 4- (2)- 16d 0 EA. 2X4 20 AT PARALLEL F.J. OWNER: PER FOUNDATION PLAN. 2X LARGEST PROVIDE A. B. BORE DIA. BORING 5- A-35 0 2*-0" D.C. 7- A-35 0 16" O.C. 0 0 6'-0" O.C. & 4/2" MIN. OR SEE SHEAR WALL 10 8- 2X4 P.T. D.F MUDSILL W/ OIA MAX . FRM. 3 6 3 SCHEDULE OR U.N,O. L L X 10** L. A.B. PER PLAN W/ w BLANCA FREY •.L SILL END 6- 2X STUDS 0 16" O.C. X 2/2 " X tu SHEAR WALL PER PLAN THK. PLATE WASHER SEE SHEAR WALL SCHED. 7- FRACTION WHERE OCCURS 12" MIN I OF JOIST 2X6 2X8 2XIO 2XI2 2X14 FOR SHEAR TRANSFER 0 9- CONCRETE FTN'G PER PLAN /2 " l!/A­ 2Zg.. z -- ---------------------------------- V 2001COC SHEAR WALLS 8- 2X BLK'G 0 48" D.C. 10- (1) -4 REBAR TOP & BOT. D/6 N I 1 11/8, FIRST BAY ONLY (714) 542 3275 D/3 1114 23/a" 3" 3LL 43 ­ SECTION 2320.8.3 - r 19 EXTERIOR BEARING WALL 15 BORED OR NOTCHED JOIS11 SHEAR TRANSFER AT FRAMING TS NTS GABLE END INTERIOR FOOTING JOB DESCRIPTION. 0 833 SQ FT I -STORY 0 ADDITION: 1 RIDGE BOARD OR HIP D T 0 RAFTER PER PLAN 11 V) ( BEDROOMS, 2 RAFTER PER PLAN 2 w 11 11 6 2 THROOMS, 3 KITCHEN 3 4X4 KING POST < NSION) w BORED HOLES MAX 40Z OF STUD 2 7 I 4 TOP PLATE WIDTH @ BEARING WALLS, 607 MAX. 0 NON -BEARING WALLS. 5 2- 2X CEILING JOIST W. A35 EA SIDE TO K.P. MIN- A NOTCHES- MAX.DEPTH 25X OF STUD 6 4 6 SIMP PC AT TOP PLT. WIDTH 0 BEARING WALLS, 40Y MAX, a NON -BEARING WALLS. 7. 3- 16d F.N. TO RIPPED 'KING POST z —DETAILS 4 0 1/1 STUD 11 I 2X BLK'G W/ 16d 0 8" O.C. 00 5 0) TO LEDGER, TYP. 6 1- 4X4 0 POST WHERE m 7 2 SIMP TS9 0 48" O.C. OCCURS W/ ST6215 :7 3 3 2X LEDGER W/ 2 -16d c"! IL 7 EA. SIDE 2- FLR. SHEATING PER CEA. STUDtlj PLAN 0/ 2X6 F.J. 0 z 4 2X BLK'G Q 48" O.C. . < 16" ()-C- W/ R-19 INq 'SIMPSON' NO. POST BOLT z CONC. BOLT er Le HB Se IMIN. PST SIMP. SSTS MAX. LOAD HD2A 1 (2)% % 112" 4y241/2 14X4 16 27751 HD5A (2) y4 Y4 16" 51/4 3 4X4 20 4010 HD6A (2) ya ya 24"61/83V24X6 28 5510 HD8A (2) % 24" 61/8131/2_4X6 28 7910 HD10A (2) % ye 24" 6Ysj3y21 4X6 28 9990 FRACTION OF STUD 2X4 2X6 2X8 NO7F­ NOTCH & BORE NOT TO OCCUR ON SAW STUD WITHIN 36" OF EACH OTHER. 11finq �Ioel 4 — EXISTING T NEW 5 CONT. SHEARPANEL W/ BLK'G & E.N.0 PLY'D SHR..WALL ONLY 6 2X RR PER PLAN 7 ROOF SHT'G PER PLAN 8 (E) 2X STUDS a 16" O.C. - b, IN 3- 2-2X BLK'G C4 4- 4X GIRDER PER PLAN 5- A-35 EA. SIDE 6- 8"X 8" X2" P.T. PLATE W/ %" DIA A..B. 251 D 13/aR, lyf,, 40Y D ' 3" 2!/ 6-01 D 2" 31/4'. 41/4 LItj4 9 WALL FINISH PER PLAN 7- CONC. PIER SECTION 2320.11.9- 2320.11.10 10 2X BLK'G 181, so. 8- 4X4 CRIPPLE POST 11 E.N. W/ 2- A35F TO GIRDER 20 KING POST 16 BORED OR NOTCHED STUDS NTS 12 SHEAR TRANSFER 8 CONCRETE PIER 4 DRAWN: AL CHECKED - DATE: JUN-13-04 JOB NO: SHEET NUMBER- SDL-1"