HomeMy WebLinkAbout10147702.pdf1 2 1 3 1 4 1 5 1 6 1 7 10 11 1 12 DWG # DRAWING TITLE ISSUE DATE --AL.SprM - 1► INV � /� A' ANA, SANTA 1446 S A `� T A ANA CA ARCHITECTURAL T-1 T-2 ARCHITECTURAL DATA SHEET EXISTING SITE PLAN FOR REFERENCE ONLY 1/07/05 1/07/05 1G / li,.(77i?/ SOUTH COAST PLAZA 3611 SOUTH BRISTOL ST. SUITE B A-1.1 FINISH FLOOR PLAN 1/20/05 A-1.2 FINISH SCHEDULE 1/07/05 A-2.1 FIXTURE AND FURNITURE PLAN 1/07/05 { °_ A10 y "----- CA-_` _ ...: ,_... !1`' .. a..._. >_,, 1446 SANTA ANA, fl --� TH z SOU COAST PLA A �, j I " lJi f`!' kl I `�t V` €i"yilfL�V hPu €ray Oyu a A' ,� I u' i"ram ;c ra , , is 9 fW it,M3 G ges � 1 3611 SOUTH BRISTOL ST., w^`Ell t, i L SUITE B �� e =. 1 °o' h >'c� 3� ,ion f� ii Q: h � - i'�i3�f Of s$i.i26( a Eaia. SHALL NOT SANTA CA 92704 � �1fdaa� of �6oy ANA, z Sl av a -I tetior € rk only, I i 4,L. f [. �'° .. u is a ,o ex4r,'V �r aftenst "; r� "� SANTA ANA, CA 92704 A-2.2 PARTIAL PLAN AND INTERIOR ELEVATION 1/20/05 A-3 REFLECTED CEILING PLAN 1/20/05 PROJECT TEAM A-4 WALL TYPES, SCHEDULES & DETAILS 1/07/05 OWNER'S PROJECT MANAGER A-5 ELEVATIONS AND SECTIONS 1/20/05 TRAMMELL CROW SPRINT PCS PROJECT MANAGER 6100 SPRINT PARKWAY OVER o p: KSOPHKO410-4A554 OVERLAND PARK, KS 66251 PHONE; (913) 315-5110 CONTACT: RON GERARD ron.d,gerard@mail.sprint.com ARCHITECT DETAILS 1/07/05 G-1 GENERAL NOTES AND SPECIFICATIONS 1/07/05 G-2 SPECIFICATIONS 1 /07/05 G-3 SPECIFICATIONS 1/07/05 G-5 TITLE 24 INTERIOR DETAILS 1/20/05 C7 CARRILLO ARCHITECTURAL GROUP, INC. 11231 GOLD EXPRESS DR., SUITE 103 GOLD RIVER, CA 95670 PHONE: (916) 266-6000 FAX: (916) 266-6006 CONTACT: NATE HENINGER nateheningerC�carrilloag.com MEP ENGINEERS ENGINEERING M1 HVAC PLAN 1/07/05 M2 HVAC DETAILS AND SCHEDULE 1/07/05 MECHANICAL SPECIFICATIONS 1/07/05 M4 TITLE 24 CALCULATIONS 1/07/05 M5 TITLE 24 CALCULATIONS 1/07/05 HENDERSON ENGINEERS 832E LENEXA DRIVE, SUITE 400 LENEXA, KS 6 PHONE: (913) 307-5464 FAX: (913) 307-5400 CONTACT: TREVOR JONES trevor.jones@hendersonengineers.com LANDLORD E1 ELECTRICAL LIGHTING PLAN 1/07/05 E2 ELECTRICAL POWER PLAN 1/07/05 E3 ELECTRICAL FLAT WIRE PLAN 1/07/05 F 1 5P� A� C f� ZA!YY Or '.. PK dIG; we E4 ELECTRICAL DETAILS AND SCHEDULES 1/07/05 E5 ELECTRICAL LEGEND AND SPECIFICATIONS 1/07/05 E6 TITLE 24 1/07/05 INVESTCORP / ORANGE BRISTOL, LP a ..- 280 PARK AVE, 36TH FLOOR NEW YORK, NY 10017 PHONE: (212) 577-1414 CONTACT: HEATHER MUTTERPERL LEGEND — f. _ _-. i I EGRESS EXTENDS TO PUBLIC RIGHT OF WAY. REQUIRED MINIMUM EGRESS WIDTH. DIRECTION OF EGRESS TRAVEL. �- — le_ *7TEL ° � - - - - E v I _ � CATEGORY PURCHASED BY INSTALLED BY VENDOR F9 DRAWING INDEX ALARM INSTALLER SPRINT SPRINT VENDOR BRIAN PARKHURST - SIEMENS BUILDING TECHNOLOGIES 8066 FLINT, LEXEXA, KS 66214 TEL. 913-935-6749 APC MACHINES SPRINT SPRINT VENDOR CATHY BOWDEN - NCR CORPORATION NOTE: G.C. TO BOLT APC TO SLAB 980 WALTHER BLVD., #1935, LAWRENCEVILLE, GA 30043 TEL. 770-513-9806 1� ;;7r,;� _ _.A 1�'t�`��'f �P ����`d� 1. BUILDING HAS NO SPRINKLER SYSTEM. 2. PROVIDE OCCUPANCY SIGNS CONFORMING TO APPLICABLE BUILDING CODE REQUIREMENTS. 3. PROVIDE ADDITIONAL EXIT SIGNS AND FIRE EXTINGUISHERS IN TYPE, NUMBER AND LOCATION AS DIRECTED BY THE FIRE DEPARTMENT FIELD INSPECTOR. 4. G.C. SHALL VERIFY, COORDINATE AND/OR INSTALL ANY SMOKE DETECTION AND/OR FIRE ALARM CONNECTORS AS REQUIRED PER GOVERNING MUNICIPALITY. 5. ANY REQUIRED FIRE DAMPER ASSEMBLIES INCLUDING SLEEVES AND INSTALLATION. PROCEDURES SHALL BE APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION. Li CABLING SPRINT SPRINT VENDOR TERESA LaMACCHIA - ICAS NETWORK SERVICES 42-19 23RD AVE, LONG ISLAND CITY, NY 11105 718-278-1100 ext-18 COPY, FAX, PRINTER SPRINT SPRINT VENDOR MARK C8-278HAFFIN -IKON 1220 W. CAMBRIDGE CIRCLE, KANSAS CITY, KS 66103 TEL. 913-315-3421 DOORS FRAMES &HARDWARE G.C. G.C. BRAD HEMBREE -KANSAS BUILDER'S SUPPLY CO. INC. NOTE: SPRINT TO PURCHASE KEY PAD LOCK & ELEC. STRIKE FROM VENDOR 5723 KESSLER, MERRIAM, KS 66203 TEL. 913-831-1511 EXTERIOR SIGN SPRINT SPRINT VENDOR JIM CAL LICOTT - A-eroTec GRAPHICS (ELEC. BY G.C.) 12709 EASTGATE DR, MESQUITE, TX 75181 o z a 0 ®� ® 0 _ �_.� 4K * 4K 4K � � � _._ - - - EXIT DOORS TO BE OPENABLE FROM _ I INSIDE WITHOUT USE OF A KEY OR SPECIALANY NO AND ADACOMPIANTETDOFORT THRESHOLD TEL. 972-289-9854 6. ALL REQUIRED PERMITS AND APPROVALS MUST BE OBTAINED FROM THE FIRE DEPARTMENT BEFORE BUILDINGS ARE OCCUPIED. 7. DURING CONSTRUCTION, THE G.C. IS TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A (NFPA 10) WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR. 8. CONTACT OPERATING MANAGER REGARDING FIRE ALARM REQUIREMENTS AND INSTALLATION. INSTALLATION AND DEVICES AT TENANT'S EXPENSE. TENANTS SPACE MUST MEET A.D.A. FIRE ALARM REQUIREMENTS. I `T '" ", n _t zr --. - FIXTURES SPRINT SPRINT VENDOR MARK PRYZBYLKOWSKI - VIRA MFG 1 BUCKINGHAM AVE, PERTH AMBOY, NJ 08861 TEL 732-442-8472 FLOORING - VCT G.C. G.C. G.C. (TILE) FLOORING - BASE SPRINT G.C. CYNTHIA AYRES - CYNTHIA AYRES & COMPANY VINYL FLOORING, 8400 MELROSE DR, LENEXA, KS 66214 CARPET TILE TEL. 913-383-2100 INSTA-KEY SYSTEM SPRINT SPRINT VENDOR V753 A ANDERS A -SECURITY SAFE NOTE: SEE NOTES BELOW.., 1753 DDISON WAY, HAYWARD, CA 94544 TEL. 800-326-4224 EXT. 103 D 9 FIRE DEPARTMENT NOTES LIGHTING SPRINT G.C. DWAYNE LAW - LIGHTING MANAGEMENT P.O. BOX 537 120 N. MAIN ST., NEW YORK CITY, NY 10956 EXTENDS TO PUBLIC RIGHT OF WAY C 1 EGRESS /ACCESSIBILITY PLAN TEL. 845-638-1950 MUSIC SPRINT SPRINT VENDOR GARY STUTLER - MUZAK 2828 WEST PARKER ROAD, SUITE 202GX, PLANO, TX 75075 PROJECT LOCATION OCCUPANT LOAD (CHAPTER 10) TEL. 972-867-7612 1446 SANTA ANA, CA (SOUTH COAST PLAZA) SECTION 1003.2.2 3611 B SOUTH BRISTOL STREET SQ. FT. USED FOR COMPUTING UNDER CARPET SPRINT G.C. BILL NEUSTADT - ELECTRONICS SUPPLY COMPANY NOT TO SCALE ` WIRING 4100 MAIN STREET, KANSAS CITY, MO 64111 NOTE: SEE NOTES BELOW... TEL 913-220-5008 FRANK LINCOLN TECH SUPPORT TEL 336-727-5824 SANTA ANA, CA 92704 OCCUPANT LOAD = 2,676 S.F. TOTAL SQ. FT. = 2,892 S.F. REFERENCE CODES SECTION 1003.2.2. 2001 CBC MERCANTILE GRADE FLOOR AREAS/30= 2001 CIVIC 1,828 S.F. / 30 = 61 OCCUPANTS 2001 CPC OFFICE / 100 = 771 S.F. / 100 = 8 OCCUPANTS STORAGE / 300 = 77 S.F. / 300 = 1 OCCUPANTS 1999 NEC TOTAL OCCUPANTS 61 + 8 + 1 = 70 OCCUPANTS SECTION 1003.2.2.2 TOTAL # OF EXITS REQUIRED = 2 EXITS PROVIDED = 2 OCCUPANCY CLASSIFICATION (CHAPTER 3� SECTION 309 SECTION 1003.2.3.2 MERCANTILE GROUP M EGRESS WIDTH PER PERSON NONSPRINKLERED SYSTEM ( ) TYPE OF CONSTRUCTION (CHAPTER 6) 0.2 X 70 OCCUPANTS = 14" SECTION 601 TABLE 6-A 6O" PROVIDED TYPE II-N FIRE PROTECTION SYSTEMS (CHAPTER 9) SECTION 1004.2.5.2.2 MAXIMUM TRAVEL DISTANCE 200' MAX (NONSPRINKLERED SYSTEM) SECTION BUILDING BUILDING HAS NO SPRINKLER SYSTEM SECTION 1005.3.3.1 WIDTH OF EXIT PASSAGEWAY WIDTH NOT LES THAN 44" (<50 OCCUPANTS) ACCESSIBILITY (CHAPTER 11) THESE PLANS COMPLY WITH ALL OF THE PROVISIONS SET FORTH IN THIS CHAPTER AND WITH "THE AMERICANS WITH DISABILITIES ACT' N mV' Cn ,- cn o � Of I— m N U � In m 73 (NORTH W cn z M cn W MACAR HUR BLVD PRO ECT LOG TION W SUNFLO ER AVE o 55 NONRESIDENTIAL ENERGY STANDARDS COMPLIANCE (TITLE 24, PART 6, CH. 1) ENVELOPE MANDATORY MEASURES • INSTALLED INSULATING MATERIAL SHALL HAVE BEEN CERTIFIED BY THE MANUFACTURER TO COMPLY WITH THE CALIFORNIA QUALITY STANDARDS FOR INSULATING MATERIAL. • ALL INSULATING MATERIALS SHALL BE INSTALLED IN COMPLIANCE WITH THE FLAME SPREAD RATING AND SMOKE DENSITY REQMTS. OF SECTIONS 804 AND 802.2 OF THE U.B.C.. • ALL EXTERIOR JOINTS AND OPENINGS IN THE BUILDING ENVELOPE THAT ARE OBSERVABLE SOURCES OF AIR LEAKAGE SHALL BE CAULKED, GASKETED, WEATHER-STRIPPED OR OTHERWISE SEALED. • SITE CONSTRUCTED DOORS, WINDOWS AND SKYLIGHTS SHALL BE CAULKED BETWEEN THE UNIT AND THE BUILDING, AND SHALL BE WEATHER-STRIPPED (EXCEPT FOR UNFRAMED GLASS DOORS AND FIRE DOORS. • MANUFACTURED DOORS AND WINDOWS INSTALLED SHALL HAVE AIR INFILTRATION RATES CERTIFIED BY THE MANUFACTURER PER ASTM E283. MANUFACTURED FENESTRATION PRODUCTS MUST BE LABELED FOR U-VALUE ACCORDING TO NFRC PROCEDURES. SECURITY SPRINT SPRINT VENDOR BRIAN PARKHURST - SIEMENS BUILDING TECHNOLOGIES 8066 FLINT, LENEXA, KS 66214 TEL. 913-935-6749 PLAN CHECK COMMENTS 1/20/05 SECURITY CAMERA SPRINT SPRINT VENDOR BRIAN PARKHURST - SIEMENS BUILDING TECHNOLOGIES 8066 FLINT, LEXEXA, KS 66214 TEL. 913-935-6749 D ISSUED FOR PERMIT AND BID 1/7/04 No. Revisions / Submissions Date SHELVING SPRINT G.C. (U.O.N.) GREG PATON - CF CLARK ASSOCIATES, INC. 2455 WISCONSIN AVE., DOWNERS GROVE, IL 60515 TEL. 630-493-9860 CARRILLO I . A R C H I T E C T U R A LGROUP I N C J. Steven Carrillo 11231 Gold Express Dr, A.I.A. C11.222 Suite 103 Gold River, CA 95670 FAX z 66-60 o FAx 2ss-soos THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT, THE DRAWING IS NOT FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITE . m CEILING (ECOPHON) SPRINT SPRINT VENDOR GEORGE DAVIS - RP & ASSOCIATES, INC. 13208 EL MONTE, LEAWOOD, KS 66209 TEL. 913-231-8071 CLOUD SPRINT SPRINT VENDOR BOB PARKER — KMDI 400 FUNSTON, P.O. BOX 15316, KANSAS CITY, KS 66115 TEL 913-281-4200 NOTE: G.C. Terminates electrical; Sprint vendor terminates data; G.C. Places both data and electrical. NOTE: G.C. Responsible for coordinating the schedule, delivery, and installation of all vendor provided items. G.C. is P 9 rY P additionally responsible for coordinating all review to plans with any and all Sprint vendors. Drawing Title ARCHITECTURAL DATA SHEET Q NOTE: Project Superintendents contact Virginia Anderson ®Security Safe 15 calendar days before punch to set-up installation of InstaKey lock system at all customer entrances to the store. This installation must occur day of punch. Seal AR'Cy = `�� ��REN'8��52 ::� OF CALIF Drawn TCB Checked N No. 04139.66 Date Scale FULL Al VAC I N ITY MAP A3 MANDATORY MEASURES A5 RESPONSIBILITY SCHEDULE A9 CODE NOTES NOT TO SCALE Drawing No. T 1 2 3 4 5 6 7 8 9 10 11 12 14 1 2 3 4 5 1 6 1 7 8 1 9 1 10 11 12 S 0 P -dwomt - 1446 SANTA ANA, CA SOUTH COAST PLAZA 3611 SOUTH BRISTOL ST. MACARTH U R BOULEVARD SUITE B SANTA ANA, CA 92704 PROJECT TEAM OWNER'S PROJECT MANAGER TRAMMELL CROW SPRINT PCS PROJECT MANAGER 6100 SPRINT PARKWAY Mailstop: KSOPHK0410-4A554 OVERLAND PARK, KS 66251 PHONE; (913) 315-5110 CONTACT: RON GERARD ron.d.gerard@mail.sprint.com ARCHITECT CARRILLO ARCHITECTURAL GROUP, INC. 11231 GOLD EXPRESS DR., SUITE 103 GOLD RIVER, CA 95670 PHONE: (916) 266-6000 FAX: (916) 266-6006 CONTACT: NATE HENINGER nateheninger®carrilloog.com MEP ENGINEERS HENDERSON ENGINEERS 8325 LENEXA DRIVE, SUITE 400 LENEXA, KS 66214 PHONE: (913) 307-5464 FAX: (913) 307-5400 5 CONTACT: TREVOR JONES trevor.jones®hendersonengineers.com LANDLORD INVESTCORP / ORANGE BRISTOL, LP 3 280 PARK AVE, 36TH FLOOR NEW YORK, NY 10017 PHONE: (212) 577-1414 ® T CONTACT: HEATHER MUTTERPERL • O• s • • • • • w W• W• 1_ v/ J 0 • • O 2 2 • • • • • s s • • • ® ® 2 •• 1 �3 •® • �/ • • • ® 2 • 4 4 • o • 7 ^p 2 • • • • • o • • • • • • • • • e • • • 2 SITE NOTES: O PROJECT LOCATION v 2D EXISTING PARKING 2 2 D EXISTING HANDICAP ACCESSIBLE PARKING ' PLAN CHECK COMMENTS 1 /20/05 4O EXISTING ACCESSIBLE PATH OF TRAVEL 0 ISSUED FOR PERMIT AND BID 1 /7/04 5O EXISTING DRIVE WAY No. Revisions / Submissions Date O EXISTING RETAIL STORES 2 O7 PROVIDE A KNOX BOX, WHICH SHALL BE PERMANENTLY CARRILLO M INSTALLED ON THE STRUCTURE. VERIFY LOCATION WITH BUILDING LANDLORD. A R C H I T E C T U R A L G RO UP I N C J. Steven Carrillo 11231 Gold Express Dr. A.I.A. C11,222 Suite 103 Gold River, CA 95670 916 266-6000 FAX 266-6006 THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE DRAWING IS NOT FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT. Drawing Title EXISTING SITE PLAN FOR REFERENCE ONLY NORTH Ll Seal 0 Drawn -11- TCB Checked NSH Q b 41 -.4a CAI"b. �, Project No. 04139.66 OroDate Al EXISTING SITE PLAN GRAPH GRAPHIC SYMBOLS LEGEND LOCATED A7/G-3 _ N 1. 2 Q 9 RE 05 4� CALM 1-7-05 Scale 1"=30'-0" 1°-30'-O" NO WORK, FOR REFERENCE ONLY Drawing No. T-2 1 12 1 3 1 4 15 1 6 17 1 8 1 9 10 11 12 1 2 1 3 1 4 5 A. G.C. IS TO PROTECT ALL SURFACES BEFORE CONSTRUCTION BEGINS AND RESTORE TO LIKE -NEW CONDITIONS ONCE CONSTRUCTION IS COMPLETED. B. G.C. TO PREP FLOOR AND WALLS AS REQUIRED TO RECEIVE NEW FINISHES. C. GYPSUM BOARD CEILINGS, BLIND POCKETS, AND COVES TO BE PAINTED AS PER SPECIFICATIONS, OR MATERIAL SCHEDULE SPECIFICATIONS. D. IN AREAS TO BE PAINTED, G.C. IS TO INCLUDE IN BID PRICE, PAINTING OF SPACE WITH ONE (1) PRIMER COAT, TWO (2) FINISH COATS AS PER FINISH SCHEDULE. E. ALL FINISH SAMPLES MUST BE SUBMITTED TO CLIENT AND ARCHITECT FOR APPROVAL. F. G.C. TO FURNISH AND INSTALL REDUCING OR TRANSITION STRIP AT ALL VCT FLOORING AND OTHER FLOORING TRANSITIONS BETWEEN FLOORING MATERIALS. G. FINISHES CALLED OUT SHALL EXTEND OVER, UNDER, AND/OR BEHIND ANY ITEMS OF BUILT—IN MILLWORK, EQUIPMENT, MIRRORS, ETC. AS INDICATED ON DRAWINGS. H. WALL OR CEILING REVEALS ARE TO BE PAINTED AS NOTED ON THE PERTAINING DETAILS. CONSULT ARCHITECT FOR CLARIFICATION IF ANY DISCREPANCIES EXIST BEFORE PROCEEDING. I. VCT SHALL BE LAID IN A BASKET WEAVE DIRECTION. REFER TO FINISH PLAN FOR COLOR AND DIRECTION. J. COVE BASE TO BE USED IN ALL AREAS INDICATED. THE G.C. SHALL USE INSIDE AND OUTSIDE CORNERS AND END STOPS FOR ALL AREAS SPECIFIED. USE ROLL GOODS ONLY. K. BEFORE PROCEEDING WITH PROCUREMENT, THE RESPECTIVE INSTALLER SHALL FIELD VERIFY DIMENSIONS TO ASSURE THAT SUFFICIENT QUANTITIES OF MATERIAL ARE ORDERED TO COMPLETE THE WORK. L. UPON RECEIPT FROM THE MANUFACTURER, THE INSTALLER SHALL INSPECT MATERIALS FOR DEFECTS, FLAWS, SHIPPING DAMAGE, CORRECT COLOR AND PATTERN, PRIOR TO BEGINNING WORK, DAMAGED OR WRONG MATERIALS SHALL BE RETURNED TO THE MANUFACTURER FOR IMMEDIATE REPLACEMENT TO PREVENT DELAYS IN THE COMPLETION OF THE WORK. M. COMPLIANCE WITH THE MANUFACTURER'S REQUIREMENTS FOR HANDLING, STORAGE, INSTALLATION, AND PROTECTION IS THE EXCLUSIVE RESPONSIBILITY OF THE G.C. AND THEIR RESPECTIVE INSTALLERS. N. THE G.C. SHALL PROVIDE ONE FINAL TOUCH—UP OF PAINT SURFACES AFTER THE TENANT HAS MOVED INTO THE SPACE. 0. EXPOSED GLASS EDGES TO BE POLISHED UNLESS OTHERWISE NOTED. = P. ALL FLOORING AT ALL FRONT OF THE HOUSE AREAS MUST BE INSTALLED TIGHT TO PARTITION. Q. FINAL PROFESSIONAL CLEANUP BY G.C. R. G.C. TO PROVIDE 10 PERCENT OF ALL MATERIALS INCLUDING BUT NOT LIMITED TO FLOOR FINISHES, CEILING FINISHES, WALL BASES, ETC. FOR "ATTIC STOCK.' S. G.C. TO VERIFY CONDITION OF EXISTING FLOOR AFTER ANY OR ALL DEMOLITION. EXPOSED CONCRETE TO BE PRESENTABLE; FREE OF GLUE, STAPLES, CRACKING, ETC. FLOOR CONDITION TO BE VERIFIED FOR EVEN LEVEL. G.C. TO REPORT ANY DISCREPANCY & CONDITION TO THE ARCHITECT. T. NO SEALERS OR FINISHES TO BE APPLIED UNTIL FLOORS ARE SWEPT AND MOPPED CLEAN. U. WHEN DEMISING WALLS ARE EXISTING, THE G.C. SHALL MATCH THE EXISTING FINISH TEXTURE. V. DIMENSIONS ON DRAWINGS ARE FINISH FACE TO FINISH FACE OF PARTITIONS, COLUMNS, ETC., OR WHERE SHOWN, UNLESS OTHERWISE NOTED. DO NOT SCALE DRAWINGS . WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC REPRESENTATION. DETAIL DIMENTSIONS TAKE PRECEDENCE OVER PLAN DIMENSIONS. 01 FINISH FLOOR PLAN GENERAL NOTES W I0� 58'-6" 9„ 18" 4,-6" 9" 5'41 oD CT-2 9 11 TYP. bo tA 4 T 4 VB-1 P-2 Al 1 6 7 8 9 10 11 45'-2" T-11" 8'-0" 13'-0" LO I N 4'-6" 18" T-1" 18" T-2 (E) P-1 VB-1 I P-2 (E) P-1 VB-1 P-2 0 EXISTING EXISTING RESTROOM RESTROOM 2 103 0 104 O 103 104 I (E) (E) 0 VF-1 P-1 18" I VB-1 P-2 ; MIN. t.° A -r r ='s A ` 8'-2" I Y PASSAGE 102 CLEAR 12 4 e (N) 107A 19 D5 i /1\ SALES C ( o I I `�' ( 3 AREA Al 3 14 c.l c I N ! 101 d-5 `— N i ___ ___ !___= _==—�= A6L I 1 1 A-4 11'-0" 27'-11" 6'-4" 3 VF-1 P-1 — � 4 6 V13-1 I P-2 II w N � to FINISH FLOOR PLAN ITT-2 M I 4' —3" 9" 4' 4' 18" T-1" 18" 62'-3" TECH 108 14 VCT-1 P-1 VB-1 P-2 3'-0" 2' MIN. A INVENTORY 109 VCT-1 P-1 VB-1 P-2 1 VCT-1 P-1 VB-1 I P-2 OFFICE 105 105 A (N) A' 1 VCT— VCT-1 P-1 VB-1 P-2 MULTIPURPOSE ROOM 107 12 • 144.6 SANTA ANA, CA SOUTH COAST. PLAZA 3611 SOUTH BRISTOL ST. spn SUITE B SANTA ANA, CA 92704 PROJECT TEAM BUILDING I UTILITIES OWNER'S PROJECT MANAGER 106 TRAMMELL CROW 7 10 SPRINT PCS PROJECT MANAGER 6100 SPRINT PARKWAY Mailstop: KSOPHKO410-4A554 OVERLAND PARK, KS 66251 I PHONE; (913) 315-5110 CONTACT: RON GERARD ron.d.gerard@mail.sprint.com ARCHITECT CARRILLO ARCHITECTURAL GROUP, INC. _ 11231 GOLD EXPRESS DR., SUITE 103 GOLD RIVER, CA 95670 PHONE: (916) 266-6000 G6 FAX: (916) 266-6006 A-6 107B CONTACT: NATE HENINGER nateheninger®carrilloag.com (El MEP ENGINEERS 9 HENDERSON ENGINEERS 20 8325 LENEXA DRIVE, SUITE 400 LENEXA, KS 66214 PHONE: (913) 307-5464 FAX: (913) 307-5400 CONTACT: TREVOR JONES trevor.jones@hendersonengineers.com LANDLORD INVESTCORP / ORANGE BRISTOL, LP 280 PARK AVE, 36TH FLOOR NEW YORK, NY 10017 PHONE: (212) 577-1414 CONTACT: HEATHER MUTTERPERL O LEASE LINE — DENOTES LIMITS OF WORK. OG.C. TO PROVIDE 5/8" TYPE "X" MOISTURE RESISTANT GYP. BD. INSTALLED ON EXISTING WALL STUDS TIGHT TO UNDERSIDE OF DECK IF NOT PROVIDED BY LANDLORD. TENANT SIDE ONLY. (TYPICAL ALL WET AREAS) O DIMENSIONAL LOCATION OF ELECTRICAL STUB —UP. SEE ELECTRICAL FOR INFORMATION. O LINE OF TRANSITION OF F OOR COVERING. 1 O SEE DRAWIN E7/A-2.2 PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION, 6 SURFACE MOUNTED FIRE EXTINGUISHER CABINET LOCATION. (2A 1OBC, MANUFACTURER — KIDD, GRANGIER OR EQUAL). PROVIDE AND POST EMERGENCY EVACUATION SIGN ON WALL INDICATING PLAN OF P CE AND PATH OF TRAVEL TO BUILDING EXITS ABOVE FIRE EXTINGUISHER IN MULTTPURPOSE ROOM. O7 NEW IT/LAN RACK. O ELECTRICAL PANEL LOCATION. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 09 G.0 TO PROVIDE 5/8" TYPE "X" GYPSUM BOARD INSTALLED ON EXISTING DEMISING WALL STUDS TIGHT TO UNDERSIDE OF DECK IF NOT PROVIDED BY LANDLORD. TENANT SIDE ONLY. 10 NEW 48" X 45' PLYWOOD PHONE BOARD. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 11 DIMENSIONAL LOCATION FOR ELECTRICAL. SEE ELECTRICAL FOR INFORMATION. 12 EXISTING STRUCTURAL COLUMN TO REMAIN. PROVIDE GYP. BD. SIM. TO WALL TYPE A.. PAINT GYPSUM P-1. 13 EXISTING COLUMN ENCASED IN NEW WALL CHASE, 14 RED WALL LOCATION (RE:P-4 AND P-5 ON FINISH SCHEDULE) 15 GYPSUM BOARD REVEAL 16 PROVIDE A CONTRACTED GRADE II TACTILE EXIT SIGN REQUIRED PER CBC 1003.2.8.6.1-1 AND MUST COMPLY WITH CBC 1117B.5.6 STANDARDS. MOUNTED AT 60" A.F.F. TO CENTER OF SIGN AND INSTALLED ADJACENT TO LATCH OUTSIDE OF DOOR PER CBC 1117B.5.7 17 LOCATION OF KEY PAD. SEE ELECTRICAL DRAWINGS FOR INFORMATION. 18 ALIGN FACE OF NEW WALL WITH FACE OF EXISTING WALL. 19 ALIGN CARPET WITH LIMIT OF RED WALL, TYP. NOTE: STORAGE, DISPENSING, OR USE OF ANY FLAMMABLE OR COMBUSTIBL. PROVIDE DOOR THRESHOLD TO MEET ALL APPLICABLE BUILDING AND ADA CODES. LIQUIDS, FLAMMABLE GASES, AND HAZARDOUS CHEMICALS SHALL CO)MPIL 1 WITH UNIFORM FIRE CODE REQUIREMENTS. NORTH7-0 ) 71DIql GRAPHIC SYMBOLS LEGEND A10 FLOOR ITN LOCATED A7/G-3 SHEET NOTES 7 1 8 1 9 1 10 1 11 1 12 EXISTING PARTITION T1 REMAIN. PATCH AND REPAIR TO AS NEW CONDITION. NEW PARTITION ��Ilr ON SHEET A-4) LEASE LINE INDICATES ITEMS ABOVE/OR DEMO C-1 11 di% 6 SEE FINISH SCHEDULE ®INDICATES WALL FINISHES ��,,, SEE FINISH SCHEDULE INDICATES BASE FINISHES SCHEDULE WjINDICATES DOOR/FRAME SEE FINISH SCHEDULE FLOOR i WALL INFORMATION 1 PLAN CHECK COMMENTS 1/20/05 O ISSUED FOR PERMIT AND BID 1 /7/04 No. Revisions / Submissions Date CARRILLO ARCHITECTURALGROUPINC ' J. Steven Carrillo 11231 Gold Express Dr. A.I.A. 011.222 Suite 103 Gold River, CA 95670 916 266-6000 FAX 266-6006 THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE DRAWING IS NOT FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT. Drawing Title FINISH FLOOR PLAN Seal °. Drawn Checked ARC TCB NSH Project No. 04139.66 Date 1-7-05 -N-& C 1 2 Scale 0 CA�O Drawing No. A-1.1 1 2 3 4 5 6 7 8 9 1C 11 12 PAINT P-1 MANUFACTURER: BENJAMAIN MOORE (800) 344-0400 lvr spfin PRODUCT: SANDYHOOK GREY HC108 FINISH: EGGSHELL (RESTROOMS -- SEMI -GLOSS) LOCATION: WALLS TYPICAL, U.N.O. 1446 ,� � � T f� A A' CA NOTE: BACK OF HOUSE WALLS TO RECIEVE ONE FINISH COAT ONLY. SOUTH AST PLAZA P-2 MANUFACTURER: BENJAMAIN MOORE (800) 344-0400 3611 SOUTH BRISTOL ST. PRODUCT: SANDYHOOK GREY HC108 SUITE B FINISH: SEMI -GLOSS, ENAMEL LOCATION: (TYPICAL) DOOR FRAMES AND TRIM SANTA ANA CA 92704 PROJECT TEAM P-3 MANUFACTURER: BENJAMAIN MOORE (800) 344-0400 PRODUCT: CEILING WHITE FINISH: FLAT OWNER'S PROJECT MANAGER TRAMMELL CROW LOCATION: GYPSUM CEILINGS P-4 MANUFACTURER: SHERWIN WILLIAMS SPRINT PCS PROJECT MANAGER PRODUCT: RED WALL PRIMER 6100 SPRINT PARKWAY P-SHADE PRIMER P-2, MEDIUM GRAY Mailstop: KSOPHKO410-4A554OVERLAND LOCATION: RED WALL &TRIM PARK, KS 66251 PHONE; (913} 315-5110 TYPE OF PRIMER: CONTRACTOR TO DETERMINE WHETHER TO USE FAST DRYING OR STANDARD DRYING PRIMER BASED ON CONSTRUCTION SCHEDULE. CONTACT: RON GERARD ron.d.gerard®mail.sprint.com P-5 MANUFACTURER: SHERWIN WILLIAMS PRODUCT: BASE, REAL RED 6405-1362 (Y38, R158) COLORANT: Y1 YELLOW (60Z. 30) ARCHITECT CARRILLO ARCHITECTURAL GROUP, INC. FINISH: SATIN COLORANT: W1 WHITE (19) LOCATION: RED WALL & TRIM COLORANT: R4 NEW RED (40Z. 42) 11231 GOLD EXPRESS DR., SUITE 103 GOLD RIVER, CA 95670 NOTE: SEE WALL ELEVATIONS DETAIL Al SHEET A-5 FOR ADDITIONAL INFORMATION PHONE: (916) 266-6000 FAX: (916) 266-6006 SEE SPECIFICATIONS FOR LIST OF ADDITIONAL APPROVED PAINT MANUFACTURERS. CD CONTACT: NATE HENINGER nateheninger®carrilloog.com FLOORING MEP ENGINEERS HENDERSON ENGINEERS CT-1 CARPET TILE (METER X METER) 39"X39" MFG: TBD PRODUCT: TBD 8325 LENEXA DRIVE, SUITE 400 FLAMMABILITY: TBD LENEXA, KS 66214 SMOKE DENSITY: TBD PHONE: (913) 307-5464 COLOR: TBD FAX: (913) 307-5400 LOCATION: OPEN SALES AREA CONTACT: TREVOR JONES trevor.jones@hendersonengineers.com CT-2 CARPET TILE (METER X METER) 39"X39" LANDLORD INVESTCORP / ORANGE BRISTOL, LP MFG: TBD PRODUCT: TBD L� FLAMMABILITY: TBD 280 PARK AVE, 36TH FLOOR SMOKE DENSITY: TBD NEW YORK, NY 10017 COLOR: TBD PHONE: (212) 577-1414 LOCATION: BEHIND POS STATION CONTACT: HEATHER MUTTERPERL VF-1 VINYL FLOORING MANUFACTURER: CENTIVA PRODUCT: ULTRAPLANK (036", BEVEL EDGE) FLAMMABILITY: CLASS B SMOKE DENSITY: <450 COLOR: UP 1129 WEATHERED ELM LOCATION: OPEN SALES AREA VCT-1 VINYL COMPOSITION TILE MANUFACTURER: ARMSTRONG PRODUCT: IMPERIAL TEXTURE FLAMMABILITY: ASTM-E-648: P 0.45 (CLASS 1) SMOKE DENSITY: ASTM-E-662: 0 450 (CLASS 1) COLOR: 51830 COTTAGE TAN DIMENSION: 12" X 12" (1/8" GAUGE) (INSTALL IN "BASKET WEAVE" PATTERN) BASE VB-1 VINYL WALL BASE MANUFACTURER: JOHNSONITE PRODUCT: COVE BASE o FLAMMABILITY: ASTM-E-648: P 0.45 (CLASS 1) FIRE RESISTANCE: ASTM-E-84/NFPA 255: CLASS 1 SMOKE DENSITY: ASTM-E-622: 0 450 (CLASS 1) COLOR: #29 MOONROCK DIMENSION: 4' X 1/8" THICK MILLWORK PL-1 PLASTIC LAMINATE PRODUCT: PIONITE - GREIGE SG210 SUEDE LOCATION: BREAK COUNTER CEILING CLG-1 24" X 48" LAY -IN CEILING: (SEE A5/A-4) TILE: ECOPHON FOCUS DG t PLAN CHECK COMMENTS 1 20 05 / / LAY -IN TILE GRID: 15/16" BASIC EXPOSED TEE-24 GRID (D ISSUED FOR PERMIT AND BID 1 /7/04 LOCATION: REFER TO REFLECTED CEILING PLAN FIRE RATING: MEETS PER: ASTM E84, BS476 PARTS 6 & 7, DIN 4102, NFP 92-501 & NFP 92-510 No. Revisions /Submissions Date COLOR: WHITE 010 CLG-2 GYPSUM BOARD: (SEE C5/A-4) CARRILLO GYPSUM ASSOCIATION (1) LAYER 5/8" THICK GYP. BD. A R C H I T E C T U R A L G R O UP I N C SECURED TO UNDERSIDE OF EXISTING CEILING JOISTS. J. Steven Carrillo 11231 Gold Express Dr. COLOR: SEE FINISHES FOR PAINT A.I.A. C11.222 Suite 103 Gold River, CA 95670 916 266-6000 FAX 266-6006 M CLG-3 24" X 45' LAY -IN CEILING: (SEE A5/A-4) THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY TILE MANUFACTURER'S STANDARD SQ. EDGE UCG STANDARD #562 RIGHTS THESEVPLANs DOEASOANDA ESIIGONS PYRIGHT WHCHAND AREONOT T OROPERTY BE REPRO UCED,IN LAY -IN TILE GRID: 15/16" EXPOSED TEE CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY LOCATION: REFER TO REFLECTED CEILING PLAN TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE DRAWING IS NOT FIRE RATING: GLASS A .. .. ,.,.. FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT. Drawing Title COLOR: WHITE FINISH I SCHEDULE' . Seal AK C Dry n /I TCB Checked NSH NOTE: SEE SPECIFICATIONS FOR LIST OF ADDITIONAL APPROVED PAINT MANUFACTURERS. ttN Cq�,� f�y' Project No. 04139.66 �. Date A9 FINISH SCHEDULE K o J' ` N-C1 12)d tiQ 1-7-05 Scale OF A���O Drawing No. A-1.2 ,y 1 2 3 4 5 6 7 8 1 9 10 11 12 1 1 2 13 4 15 16 17 8 1 9 10 1 11 12 spfiw - 1446 SANTA ANA, CA SOUTH COAST PLAZA 3611 SOUTH BRISTOL ST. 77 SUITE B S -sH-2 - J VCR T-1 >PROJECT EXISTING EXISTING RESTROOM RESTROOM OFFICE r- �' �H-1 IT/LAN BUILDING SANTA ANA, CA 92704 TEAM i 103 104 '1 '1 / 105 ( 106 OWNER'S PROJECT MANAGER TRAMMELL CROW N / CLEAR LEA SPRINT PCS PROJECT MANAGER • 103 104 105 T `. 6100 SPRINT PARKWAY CH-1 L (EI IE) (N) Mailstop: KSOPHK0410-4A554 / OVERLAND PARK, KS 66251 PHONE; (913) 315-5110 j CH-7 CONTACT: RON GERARD ron.d.gerard@mail.sprint.com d i T-2Lz= = ARCHITECT CARRILLO ARCHITECTURAL GROUP INC. ' 11231 GOLD EXPRESS DR., SUITE 103 - GOLD RIVER, CA 95670 N MULTIPURPOSE CH-7 i ROOM PHONE: (916) 266-6000 FAX: (916) 266-6006 c, ( 107 107E CONTACT: NATE HENINGER noteheninger@carrilloag.com gC (E) ' REF KIT MEP ENGINEERS HENDERSON ENGINEERS SH-5 SH-2 MIC F.E. PASSAGE � � — — — — — — ° " " SA N ❑ 6 -9 12 -3 7 -0 6 -0 7 -0 15 -10 4 -2 0 I c� ❑ 8325 LENEXA DRIVE, SUITE 400 LENEXA, KS 66214 PHONE: (913) 307-5464 FAX: 913 307-5400 5 1/2" 3,_9" T-8 1/2" 2'-8 1/2"11 4'-1' T-9" J CONTACT: TREVOR JONES trevor.jones@hendersonengineers.com X I 15'-10" LANDLORD INVESTCORP / ORANGE BRISTOL, LP 280 PARK AVE, 36TH FLOOR I I I I I I I I I I I I I I I I I I F'E' PHONE: (212) 577-1414 aO 430 449 450 451 453 455 457 458 459 442 aO '`' CONTACT: HEATHER MUTTERPERL UNI-STRUT�VE UNI-STRUT ABOVE CLOUD ABOVE CL1 I a I CL1 CLOUD ABOVE (N) 107A UN TTULA�O— —_— --- _-- ' — — — — —4 — — — — — — — — — — t- — — — — — — — — — — — 's;4 c° 13'-1" 17'— W 6'-0" (N) 108 r o g � v�i <CF-3 - CH-1 -' FRONT OF HOUSE PLASMA 443 446 1 APC 0 0 SCREEN n 401 WIND❑W BANNER 403 WIND❑W BANNER 404 CASH WRAP 405 TECH TABLE 1 407 ,) o o SALES 447 406 ABO VE� I J 406 TECH TABLE 2 407 GREETER TABLE O AREA O O I� TECH 101 �J `�— I I m 108 408 S❑LUTI❑NS TABLE 1 409 S❑LUTI❑NS TABLE 2 o 0 PROVIDE ADA COMPLIANT 410 SHOWROOM GRAPHIC RH1 411 SHOWROOM GRAPHIC RH2 ® , ( 412 SHOWROOM GRAPHIC RH3 413 SHOWROOM GRAPHIC RH4 SIGN INDICATING COMPLIANT U - 414 SHOWROOM GRAPHIC RH5 415 SHOWROOM GRAPHIC LH1 ® POS STATION 405 O ■ ❑ 416 SHOWROOM GRAPHIC LH2 417 SHOWROOM GRAPH LH IC 3 444 445 CH-1 O 418 SHOWROOM GRAPHIC LH4 419 SHOWROOM GRAPHIC LH5 ® CH-3 CH-3 O O I 426 CASH WRAP SCREEN 429 LARGE TECH ROOM GRAPHIC O O J 430 ACCESSORY WALL PANEL 1 431 HANDSET DISPLAY CABINETS 1 GLASS 13'-1" 1T-6" 432 HANDSET DISPLAY CABINETS 2 433 HANDSET DISPLAY CABINETS 3 WALL I 435 HANDSET DISPLAY CABINETS 5 437 HANDSET DISPLAY CABINETS 7 UNI-STRUT ABO7-8-= _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 404 _ _ 404 _"" " `~° 109fiz 439 HANDSET DISPLAY CABINETS 9 440 HANDSET DISPLAY CABINETS 10 — ' 441 HANDSET DISPLAY CABINETS 11 442 ACCESSORY WALL PANEL 2(VM) I-- — — — — — — — — — — — - (- — — — — — INVENTORY 443 FREESTANDING ACCESS CABINETS 1 444 FREESTANDING ACCESS CABINETS 2 r — ZL�UD��VE — —I o b M0UD A�OV-€ — — — — — — — — — ! - ( :, 109 CO 445 FREESTANDING ACCESS CABINETS 3 446 FREESTANDING ACCESS CABINETS 4 CLl -1 ;r, CL1 = 447 FREESTANDING ACCESS CABINETS 5 448 ACCESSORY WALL PANEL 3 UNI-STRUT ABOVE , 449 HANDSET DISPLAY CABINETS 12 450 HANDSET DISPLAY CABINETS 13 I I 451 HANDSET DISPLAY CABINETS 14 453 HANDSET DISPLAY CABINETS 16 — — — — — — — — — — — — — — — — — J — — — — — — — — _J I 455 HANDSET DISPLAY CABINETS 18 457 HANDSET DISPLAY CABINETS 20 1F' FUTURE I 1 I s 458 HANDSET DISPLAY CABINETS 21 459 HANDSET DISPLAY CABINETS 22 \ aO N UNI-STRUT ABOVE _! 460 ACCESSORY WALL PANEL 4 430 431 432 433 435 437 439 440 441 442 I --=- =-� �== � I I I I I I I I I I I I I I I I I I I I -� SH-8 SH-8 BACK OF HOUSE i IE) _ _ _ _ _ _ _ _ _ _ _ _ _ _ BC BREAK COUNTER 48L X 25D S SAFE PLAN CHECK COMMENTS 1 20 05 CFP COPIER/FAX/PRINTER T-2 CAFE TABLE 101 I I CH-1 CHAIR LF-1 LATERAL FILE 1 ISSUED FOR PERMIT AND BID 1 /7/04 CH-3 CUSTOMER CHAIR @ SOLUTI❑NS TABLE No. Revisions / Submissions Date T-8 / 1 1/ 2" T-8 2" 4'4' 2'-10" 3'-10" CH-7 CHAIR (STACKABLE) 3'-9" 1'-9" TB TECH BENCH T-0" 6'-T 7'-0" 24'-3" FC VCRR FILE CABINET VCR/SECURITY REC. DEVICE BY OWNER CARRILLO MIC MICROWAVE REF COMPACT REFRIGERAT❑R ARCHITECTURALGROUPINC WB-36 WHITE MARKER BOARD - 36L X 48H J. Steven Carrillo 11231 Gold Express Dr. A.I.A. C11.222 suite 103 WB-46 WHITE MARKER BOARD - 48L X 72H Gold 2ss 6000A sss�o m IT/LAN IT/LAN PHONEBOARD-NEW 4' X 4' X 3/4" FIRE RATED PLYWOOD BACKBOARD FAX 266-6006 THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY INSTALLED BY G.C. KIT FIRST AID KIT - PROVIDED BY OWNER, INSTALLED BY G.C. RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, KP KEY PAD NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE PS PLASMA SCREEN EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE DRAWING IS NOT FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT. SH-2 WALL MOUNT SHELF -48L X 12DL X 30 13/16H Drawing Title SH-5 LIGHT DUTY SHELF - 48L X 18D X 86H SH-8 LIGHT DUTY SHELF - 48L X 18D X 60H SH-7 LIGHT DUTY SHELF - 36L X 18D X 60H FIXTURE AND FURNITURE PLAN T-1 MANAGER'S DESK - 59 1/2 X 28 WS-1 WORK SURFACE - 48L X 25D S R Dr + TCB Checked NSH NORTH FOR ADDITI❑NAL INFORMATION SEE FIXTURE AND FURNITURE SCHEDULE, �� CA �T Project No. SHEET A8/A-4. �4'��` 04139.66 Q Date Al FIXTURE AND FURNITURE PLAN NOTE: GRAPHICS SYMBOL LEGEND A10 FIXTURE LEGEND � 1-7-05 12EN1 052 � Scale LOCATED A7/G-3 j.,, 1/4" = 1,4, C 04 �F 1/4" =1-0I' pLl� Drawing No. A-2.1 � 1 2 3 4 5 6 7 8 9 10 11 12 '' 1 2 1 3 1 4 5 6 7 18 1 9 1 10 11 12 spfin - 1446 SANTA ANA, CA 7'-0" 7'-7" SOUTH COAST PLAZA FIELD VERIFY FIELD VERIFY 3611 SOUTH BRISTOL ST. SUITE B 6 6 SANTA ANA, CA 92704 PROJECT TEAM OWNER'S PROJECT MANAGER TRAMMELL CROW _ �- --- --- ---- --- -- -- - 41 GB-2 I I GB-2 i 4 SPRINT PCS PROJECT MANAGER 6100 SPRINT PARKWAY Mailstop: KSOPHK0410-4A554 I I i 5 TA-2 TA-2 I OVERLAND PARK, KS 66251 PHONE; (913) 315-5110 6--EXISTING I EXISTING--_t 6 �j.._._.. I I ��._ ( RESTRQOM j RESTRGOM j �I > { coo l 3 3 f coo 2 m 3 B OPP / 3 CONTACT: RON GERARD ron.d.gerard®mail.sprint.com ARCHITECT CARRILLO ARCHITECTURAL GROUP, INC. 11231 GOLD EXPRESS DR., SUITE 103 GOLD RIVER, CA 95670 PHONE: (916) 266-6000 FAX: (916) 266-6006 TA-3 f r I TA-3 � 10 10 ' 12 12 ' TA-1 I j, TA-1 , CONTACT: NATE HENINGER nateheninger@carrilloog.com MEP ENGINEERS HENDERSON ENGINEERS 8325 LENEXA DRIVE, SUITE 400 LENEXA, KS 66214 - y zi�"'' 7 12 9 8 12 7 11 Al PHONE: (913) 307-5464 FAX: (913) 307-5400 CONTACT: TREVOR JONES trevor.Jones®hendersonengineers.com LANDLORD INVESTCORP / ORANGE BRISTOL, LP 280 PARK AVE, 36TH FLOOR NEW YORK, NY 10017 PHONE: (212) 577-1414 NORTH CONTACT: HEATHER MUTTERPERL E/ PARTIAL PLAN GRAPHICS SYMBOL LEGEND LOCATED A7/G-3 @ RESTROOMS GRAB BARS TO BE 1 1 /4' TO 1 1 /2" SEE SPECIFICATIONS FOR SPECIFIC BOBRICK 7O TA-3 IN DIAMETER, 250 LB IN STRENGTH, PRODUCT NUMBERS. THE GENERAL CONTRACTOR AND 1 1/2" FROM WALL. MAY SUBSTITUTE EQUAL PRODUCTS AS APPROVED BY SPRINT'S PROJECT MANAGER. STANDARD STANDARD TA-1 COMMERCIAL TA-2 COMMERCIAL SINGLE ROLL SINGLE ROLL , MIRROR o I GB-2 o 1 6" MAX GB-1 %� (D 1 00 TA-1 \� / IV A B C a ® = N C 10 RESTROOM ELEVATIONS Li SURFACE MOUNTED SURFACE MOUNTED ADA COMPLIANT TOWEL DISPENSER TOILET TISSUE DISPENSER TILT -OUT MIRROR 1/4"=1'-o" @ RESTROOMS PLAN CHECK COMMENTS 1/20/05 (D1 ISSUED FOR PERMIT AND BID 1 /7/04 W/ FRAME O GB-1 36" GRAB BAR 7O GB-2 24" MIN. It 42" GRAB BAR O EXISTING LAVATORY AND WATER CLOSET. SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. O2 5'-0" DIA, TURNING RADIUS. O 48" X 30" CLEAR FLOOR SPACE. No. Revisions / Submissions Date CARRILLO I ADA TRAP — Q z z z GUARD ; mi r 17" MIN. N N 'IF 11�O O G.C. TO PROVIDE ACCESSORIES RE: Al Q/A-2 4 EXISTING GRAB -BARS MAY REMAIN IF MEET ADA REQUIREMENTS. SHIFT FIXTURE SO CENTERLINE OF FIXTURE IS 16' FROM FACE OF WALL. LOWER GRAB BARS TO BE 33" A.F.F. O7 G.C. TO PROVIDE. O REPLACE HARDWARE WITH PRIVACY LOCK. A R C H I T E C T U R A L G R O U P I N C ' J. Steven Carrillo 11231 Gold Express Dr. A.1.A. c11.22z Gold RlOver, CA 95670 916 266-6000ul FAX 266-6006 THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE FROM THEIS F NARLESS OR T01TTEN BE USED FIORIOCONSTRUCTION RUNFTILESIGNED BYTHEDT HE IARCHI EOCT. 36' MAX, 6" MAX. 8" MIN. GRAB BARS LAVATORY MOUNTING DETAIL TOILET & ACCESSORY MOUNTING DETAIL Drawing Title PROVIDE FIRE RETARDANT BLOCKING AS REQUIRED FOR TOILET ACCESSORIES INSTALLATION. O9 REPLACE BROKEN HARDWARE WITH NEW PRIVACY LOCK. 10 LOWER MIRROR TO BE 40P A.F.F. 0 PARTIAL PLAN AND INTERIOR ELEVATION 11 PROVIDE GOOSENECK FAUCET. 0 12 INTERIOR SIGNAGE PER DETAIL A7/G-5. S `; (Z �Sj�� r � , C] ,22 y REN 8 O4� o cAL1� Drawn TCB Checked NSH roject No. 04139.66 Date 1-7-05 A7 RESTROOM ACCESSORIES A10 RESTROOM FLOOR PLAN Scale 1/4" = 1'-0,1 MOUNTING HEIGHTS NOTES Drawing No. A-2.2 PON 6 7 8 9 10 11 12 I 2 3 4 5 6 7 8 9 10 11 12 spfiw 0LINE OF GYP. BD. SOFFIT. A. SEE ARCHITECTURAL/CONSTRUCTION PLAN FOR WALL O2 CENTER LIGHT FIXTURE ON FIXTURE/GRAPHIC OR STOREFRONT LOCATIONS AND ADDITIONAL INFORMATION. BELOW, TYPICAL. B. SEE SCHEDULES AND LEGEND SHEET FOR ROOM FIXTURE INFORMATION. - D SUSPENDED FIXTURE "CLOUD" W/ BOTTOM AT T-6" A.F.F. C. SEE ELECTRICAL SHEETS FOR EXACT LENGTH, MODEL E E pp�� /� pp�� 1446 S A N T A A N A CA NUMBER, AND CIRCUITING INFORMATION FOR EACH OF E E O G.C. TO PROVIDE 3/4" PLYWOOD BLOCKING FULL WIDTH AND THE LIGHT FIXTURES. SOUTH COAST PLAZA DEPTH OF SOFFIT AS SHOWN IN DETAIL D8 ON SHEET A-4. D. CEILING HEIGHTS ARE AS NOTED ON PLAN. G.C. SHALL P-3 P-3 NOTIFY THE ARCHITECT IMMEDIATELY OF ANY 3fi11 SOUTH BRISTOL ST. O FULL TILE. DISCREPANCIES WITH PLANS IN RELATION TO THE SUITE B EXISTING FIELD CONDITIONS. 6� NOT USED. E. IN THE EVENT OF AN DISCREPANCY BETWEEN QUANTITY, LOCATION, AND/OR TYPE OF LIGHTING FIXTURE SANTA ANA, CA 92704 O 2'X2' METAL ACCESS PANEL FOR SIGNAGE (ie. JUNCTION BOX), BETWEEN ARCHITECTURAL AND ENGINEERING SHEETS PROJECT TEAM IF REQUIRED. PAINT P-3 TO MATCH CEILING. G.C. SHALL NOTIFY THE ARCHITECT IMMEDIATELY FOR EXISTING EXISTING BUILDING CLARIFICATION, ARCHITECTURAL SHEETS GOVERN. RESTROOM RESTROOM OFFIC UTILITIES OWNER'S PROJECT MANAGER Og EDGE LIT SIGN. INSTALL /ATTACH TO CLOUD FIXTURE. SEE F. G.C. IS RESPONSIBLE FOR COORDINATION FOR 103 104 CLG-3 10 F4- 106 TRAMMELL CROW ELECTRICAL FOR INFORMATION. INSTALLATION OF THE MUSIC SYSTEM WITH THE 10'-0" SPRINT'S VENDOR. SPRINT PCS PROJECT MANAGER = g FIXTURE "CLOUD" ELECTRICAL CHASE. SEE ELECTRICAL FOR G. VERIFY ALL DIMENSIONS FOR LIGHT FIXTURES IN FIELD. O 6100 SPRINT PARKWAY MAINTAIN RELATIONSHIP BETWEEN LIGHT FIXTURES AND INFORMATION. F4 Mailstop: KSOPHKO410-4A554 STORE FIXTURES AS DRAWN. LOCATE LIGHT FIXTURE OVERLAND PARK KS 66251 ' TRACK ON THE UNDERSIDE OF THE NEAREST FIN OF '" � ffi` 10 PROVIDE 1-5/8" X 1-5/8" UNI-STRUT AS SHOWN. ATTACH TO PHONE; (913) 315-5110 STRUCTURE FOR SUPPORT OF FIXTURE "CLOUDS'. GC TO CEILING GRID UNLESS NOTED OTHERWISE. H. EXACT LOCATIONS OF THERMOSTATS INDICATED ON ry CONTACT: RON GERARD ron.d.gerard@mail.sprint.com INSTALL UNI-STRUT & CLOUD MFG. TO INSTALL CLOUD / ENGINEERING DRAWINGS SHALL BE IDENTIFIED BY G.C. ®C CABLE SYSTEM. AND VERIFIED IN FIELD BY NCM PRIOR TO INSTALLATION. ARCHITECT CARRILLO ARCHITECTURAL GROUP, INC. 11 PLASMA SCREEN. SUPPORT TO BE PAINTED BY GC TO MATCH THERMOSTATS TO BE CENTERED ABOVE LIGHT SWITCH ADJACENT CEILING COLOR. UNLESS NOTED OTHERWISE. i. G.C. SHALL COORDINATE THE TIE—IN TO THE EXISTING 11231 GOLD EXPRESS DR., SUITE 103 CLG-3 BUILDING SYSTEMS WITH BUILDING OWNER. F4 F4 F4 GOLD RIVER, CA 95670PHONE: (916) 266-6000 J. REFER TO ELECTRICAL DRAWINGS FOR LOCATION OF EXIT EMI 10'-0" ROOM FAX: (916) 266-6006 c� LIGHTS AND OTHER LIFE SAFETY EQUIPMENT. �C I 107 CONTACT: NATE HENINGER nateheninger@carrilloag.com G 1 CEILING PLAN G 3 CEILING PLAN EQ. Q. MEP ENGINEERS HENDERSON ENGINEERS SHEET NOTES GENERAL NOTES PASSAGE E 1 F4 832E LENEXA DRIVE, SUITE 400 LENEXA, KS 66214 PHONE: (913) 307-5464 FAX: (913) 307-5400 „ D9 4 -0 CLG-2 4-0 4-0 4 -0 22-0 CONTACT: TREVOR JONES trevor.jones@hendersonengineers.com 9'-Y, A-6 OG LANDLORD P-3 INVESTCORP / ORANGE BRISTOL, LP g 280 PARK AVE, 36TH FLOOR F4 A9 G9 G11 NEW YORK, NY 10017 ` A-6 A-6 A-6 PHONE: (212) 577-1414 �I At Al At Al At CONTACT: HEATHER MUTTERPERL 8 8 10 r® r® r®J r® EM1 I---- —-------- -- —_ I- — ---------- -- ---- -1 9 L S c I I Sc — — — 9 -1 F- -1 ®C `'' w I— c —I c -- — — -j -- c — — — C -- c — — C-a —I---- Tic --- FTC-- — 1c 0r r -- F1c --- F1c —�F_2c I—� 2c 2 L— — — — --- — =-- — -- -- --- — I1J J J L J �� I 10 3 I I I 3 I 10 I 4'-10" 4'-10" 4' 7' '-7" 4'-7' 1 ' c r M 12" 8'-0" 1'-3" 4 -0" 4 -0" 10'- " 8'-U' - i r I- � CLG-3 Al L o `A1 10'-0" n CLG-1 INDICATES CEILING TYPE, SEE FINISH I TECH A1. CAVALEfTO 70W ED17 ELECT. WALL WASH.108101 SCHEDULE CPll"LAII ®C r C — CLG-1 `-- - -_ 81. RECESSED 1 HEAD COMBO 39E T6 ELECT. U I r 10'-0" INDICATES CEILING HEIGHT ABOVE FINISHED FLOOR rO,q o 7-- - --J - , LAI EQ. 5'-O" EQ. ® 4' ' 7' -7" 4'-1' 1 T 07 w 41 O B3. RECESSED 3 HEAD COMBO 39E T6 ELECT. " ®C 10 9 9 10 f --O-B P-1 INDICATES CEILING FINISH, SEE FINISH SCHEDULE g ®C C. 7' VERTICAL 1 LAMP 42W CF, MOUNT IN CEILING. 1 CEILING INFORMATION — — F1c — — — —F1c �,; — F1c — F1c — f- — F2c I— i — F2c — I,, LU INVENTOR —_� — — — _ — — — —� — —1 -j 109 ®Cc Cc. 7' VERTICAL 1 LAMP 42W CF MOUNT IN PRE-CUT HOLE "CLOUD", IN BOTTOM OF FIXTURE AIM DOWN. OC L _ = I I Sc_= J L_J I CLG-3 L ®CE CE. SAME AS TYPE C W/ EMERG. BAT. PACK. `a4 F4 —ELF_ — -- — L — — — — — — — --- -- ---- _J 10'-0„ ` 0 T/-3N 10 ®J g ®J ` ®J L ®J ` ®J 8 3 10 "' 4'-3" EXIT SIGN. EXIT SIGN SHALL BE IN BLOCK LETTERS, A MINIMUM 6:HIGH W/ A STROKE OF NOT LESS THAN 3/4". LUMINANCE ON FACE O Al Al r Al Al r Al "` SHALL BE 50 LUX. C '�1 12-9"'EM1 EM1. 2 HEAD DECORATIVE EMERGENCY UNIT 1 PLAN CHECK COMMENTS 1 /20/05 ELSc. EDGE LIT SIGN. 1 ISSUED FOR PERMIT AND BID 1 /7/04 I I I I I--------------ELSc� No. Revisions /Submissions Date F1 c. 4' STRIP 32W T8 FLUORESCENT MOUNT ON PLATFORM ON F1 c ��. TOP OF FIXTURE "CLOUD", AIM UP. �Q.CARRILLO 4'-0" 4'-0" 4'-0" 26'-3" � F2c. 2' STRIP 32W T8 FLUORESCENT MOUNT ON PLATFORM ON F2c `yQ TOP OF FIXTURE "CLOUD", AIM UP. A R C H I T E C T U R A L G R 0 U P I N 0 J. Steven Carrillo 11231 Gold Express Dr. A.I.A. 011.222 Suite 103 m F4. 2' x 4' LAY -IN FLUOR. 3 LAMP 32W T8 Gold River, CA 95670 916 266-6000 FA THE ARCHITECT, CARRILLO ARCHI ECx R6A6L GROUP INCORPORATED, HEREBY F4 RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE TOILET FAN EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE DRAWING IS NOT FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT. Drawing Title SUPPLY AIR. SEE MECHANICAL. /� REFLECTED REF LECTED - CEILING PLAN RETURN AIR. SEE MECHANICAL. ARcjy ti 1 CA f��, Dra TCB Checked NSH Project No. NORTH 04139.66 Date Al REELECTED CEILING PLAN A10 REFLECTED CEILING LEGEND 7r1:' J' t`�C 1 2 �Q '-7-05 Scale REN /05 0,4� 1 /4" = 1'—C Drawing No. A-3 ' �/4 =1 -0 �FCA1-�� 1 2 1 3 4 5 1 6 7 8 1 9 10 11 12 1 2 3 4 15 6 1 7 8 9 10 11 12 splia _ BRACE DIAG., _ IRECCTIIONS ® DOOR SCHEDULE * G C TO PROVIDE SIGNAGE ON PRIMARY EGRESS DOOR(S) STATING "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS" DOOR DATA FRAME DATA HARDWARE NOTES Al DECK OR A-4 �— — —� STRUCTURE CONTRACTOR'S OPTION: TERMINATE WALL 6 J MIN. ABOVE CEILING — 3 5/8" 25 GA. MTL. STUD W/ OR EXTEND TO DECK FLANGES CLIPPED ATTACHED TO SEE D4/A-4 DECK OR STRUCTURE. 20 GA. F DECK OVER 16'-0" AFF.) DRAFTSTOP AS REQ'D BY CODE METAL TRACK. 2G GA. METAL STUD 1/2" PLYWOOD METAL TRACK DIM. WOOD BLOCKING CEILING PER PLAN 4'- i i:IF ; ; _ ; ; i ! SEE PARTITION TYPE 1 2" 1 2" CONT. SEALANT (TYP.) N METAL FRAME mr 1446 C A w SOUTH COASTPLAZA �611 SnUTH BRISTOL ST. SUITE B SANTA ANA CA 92704 SIZE MATERIAL TYPE FINISH MATERIAL TYPE I JAMB HEAD FINISH LABEL SET No. KEY SIDE 101 * T-0" X 8'-0" EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST - - EXTERIOR MAIN EXIT DOOR 103 (E)3 -O X 8 -0 EXIST EXIST P-2 EXIST EXIST EXIST EXIST P-2 - 2 102 MUST MEET ADA 104 (E)T-O" X T-0" EXIST EXIST P-2 EXIST I EXIST EXIST EXIST P-2 - 2 102 MUST MEET ADA 105 T-0" X T-0" WD — P-2 HM — J1 H1 P-2 — 3 1G7 107A T-0" X T-O" WD - P-2 HM - J1 H1 P-2 - 5 101 107B (E)T-0" X T-0" EXIST EXIST P-2 EXIST EXIST EXIST EXIST EXIST - 4 EXTERIOR PAINT INTERIOR ONLY 108 T-0" X T-0" WD - P-2 HM - J1 H1 P-2 - 1 107 PROJECT TEAM 109 3'-0" X 7'-0" - - - GYPSUM - - - P-1 - - - NO DOOR/FRAMED OPENING = CEILING AS 1 LAYER 5/8" SCHEDULED GYP. BD. EACH SIDE J4_ I 3 5/8" 25 GA MTL. STUDS @ 16" C.C.. (20 GA., IF DECK SILL OVER 16'4" AFF. BASE AS FINISHED SCHEDULED FLOOR PRE -FINISHED SHEET -METAL HEMMED ANGLE MOULDINGS /TYP. CEILING GRID WALL ANGLE & 2" CEILING GRID WALL ANGLE. 1/2" TEMPERED GLASS. CORNER OF GYP. BD. WALL BEYOND. CEILING PER PLAN PRE -FINISHED SHEET -METAL HEMMED CHANNEL -RECEIVER MOULDING. MATCH CEILING SUSPENSION GRID METAL FINISH. PAINTED DOOR 5/8" H 1 SEE PARTITION HYPE DOUBLE MTL. STUDS OWNER'S PROJECT MANAGER TRAMMELL CROW SPRINT PCS PROJECT MANAGER 6100 SPRINT PARKWAY Mailstop: KSOPHKO410-4A554 OVERLAND PARK, KS 66251 PHONE; : RO 315-5110 CONTACT: N GERARD ron.d.gerard®mail.sprint.com ARCHITECT 1. G.C. TO VERIFY THAT EXISTING DOORS ARE IN GOOD WORKING CONDITION. 2. ALL EXISTING DOORS TO REMAIN SHALL KEEP THE EXISTING HARDWARE UNLESS OTHERWISE NOTED. 3. LISTED HARDWARE OR APPROVED EQUAL TO BE USED ONLY. 4. ALL DOORS TO BE PROVIDED WITH 12" X 34' ALUMINUM KICK PLATES AT PUSH SIDE OF ALL INTERIOR DOORS. KICK PLATES TO BE IVES 8400 SERIES, PA28-CLR FINISH OR EQUAL. 5. NEW DOOR CLOSERS FOR EXISTING EXTERIOR DOOR TO BE INSTALLED ON INTERIOR OF SPACE. 6. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 7. ALL EXTERIOR DOORS SHALL BE PROVIDED WITH WEATHER STRIPPING AT HEAD, JAMBS AND SILLS. G 3 D ETA I L CARRILLO ARCHITECTURAL GROUP, INC. 11231 GOLD EXPRESS DR., SUITE 103 GOLD RIVER, CA 95670 AT GLASS WALL AS SHOWN 1/2 1/2' CONT. SEALANT (TYP.) F N METAL 8. IF DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3" (75mm) FROM THE LATCH, MEASURED TO THE LEADING EDGE OF THE DOOR. 9. REFER TO ACCESSIBILITY DETAILS AND NOTES SHEET G-5 FOR DOORS AND DOORWAYS, ALL DOORS AND HARDWARE SHALL COMPLY. ( ) PHONE: (916) 266-6000 FAX: (916) 266-6006 CONTACT: HATE HENINGER nateheningerC�carrilloag.com MEP ENGINEERS 1 /2" TEMPERED GLAZING G DOOR SCHEDULE HENDERSON ENGINEERS Jk 42' A.F.F. FRAME V 3/4" SOLID WOOD W/ EASED EDGE CONTINUOUS 2X FIRE RETARDANT BLOCKING 3-5/8" 20 GA. METAL STUD FRAMING CONTINUOUS 3-5/5' 20 GA. MTL. STUDS @ PAINTED DOOR - DOOR JAMB 5 7/8 ANCHOR J 1 — 8325 LENEXA DRIVE, SUITE 400 LENEXA, KS 66214 PHONE: (913) 307-5464 FAX: (913) 307-5400 CONTACT: TREVOR JONES trevor.jones@hendersonengineers.com NONE SET #1: SALES /TECH ROOM DOOR 142 PAIR BUTTS: HAGER 1279BB 4 jx4 y US26D 16" O.C.. BRACE AS REQUIRED, 5/8" GYP. BD. P-1. 2' 0" _ N 1 LATCHSET: SCHLAGE D1GS US26D 1 CLOSER: NORTON 8400 US26D COVER 1 WALL STOP: IVES 407 32D 1 PEEP HOLE: 620 IVES 1 SECURITY LOCK (PUNCH KEY TYPE) LANDLORD INVESTCORP / ORANGE BRISTOL, LP 280 PARK AVE, 36TH FLOOR NEW YORK, NY 10017 F 1 WALL TYPES F3 D ETA I L F5 D ETAI L STUDS 1 KICKPLATE PHONE: (212) 577-1414 CONTACT: HEATHER MUTTERPERL SET 2: TOILET ROOM DOOR 0 1 y2 PAIR BUTTS: HAGER 1279BB 4i2'x4 y2 US26D 1 PRIVACY LOCKSET: SCHLAGE D40S US26D 3/4" = 1'-U' 1 1/2"=1'-0" AT GLASS WALL 3" = 1'-0" HEAD AND JAMB 1 DOOR STOP: HAGER 240F 1 KICKPLATE (PUSH SIDE) STUD BRACING TO STRUCTURE ABOVE Lv EXISTING FRAMING FIELD VERIFY 2-No.8 x 1-1/2" WD. SCREWS @ 24' C.C. fA. %� �� 2X6 BLOCKING � � 'V AT OC PROVIDE (ALTERNATING) BRACESCES IN BOTH DIRECTIONS 0 BLOCKING TO ACCOMMODATE 4'-0" WIDE SHELF, TYP. BLOCKING ELEVATION ® SH-2 SET #3: OFFICE MULTIPURPOSE ROOM DOOR " 1 y2 PAIR BUTTS: HAGER 1279BB 4%2 xO- US26D 1 LOCKSET: SCHLAGE D70PD US26D 1 DOOR STOP: IVES 240E 1 KICKPLATE No.10 SMS EA. SIDE BATT INSULATION FIELD VERIFY AT STUD TO HORIZ. TRACK, TYP. 1 1 /2" X 1 1 /2" 18 GA. CLIP 16GA. HORIZ. GYPSUM BOARD ONLY WHERE SCHEDULED. L` ® ® Q CI SET #4: REAR EXIT DOOR, EXISTING TO REMAIN ADD PEEP HOLE: 620 IVES ADD LATCH GUARD ADD SECURITY BAR: PHOENIX DOUBLE DEFENDER DD-QR-36 o TRACK FREE TO 16GA. DEEP MOVE VERT. IN LEG TRACK DEEP LEG TRACK, TYP. 25 GA. MTL. STUD, REFER TO WALL LEGEND FOR SIZE (20 GA. MTL. STUD WHERE INDICATED) PARALLEL ALTERNATE ATTACHMENT WHERE FULL HEIGHT GYPSUM BOARD NOT INDICATED BLOCKING ENTIRE WIDTH AND DEPTH OF STOREFRONT. STUDS CAN LIGHT SOFFIT PLAN BLOCKING NOTE: (TYP). 1. ALL BLOCKING TO BE FIRE RETARDANT PLYWOOD TYP CONTRACTOR IS RESPONSIBLE TO LOCATE AND INSTALL AS REQUIRED. PROVIDE FIRE RATED PLYWOOD GROUNDS FOR ALL SHELVING AND WALL MOUNTED ACCESSORIES. NO TOGGLE BOLTS PERMITTED. 2. PROVIDE 3/4' FIRE RATED PLYWOOD BLOCKING AT RED PHONE, COPIER, WORK TOP, (G.C. TO VERIFY WIDTH AND PROPER APPLICATION) SET #5: PASSAGE / MULTIPURPOSE ROOM DOOR 142 PAIR BUTTS: HAGER 1279BB 4i'x4 j US26D 2 2"2 1 LATCHSET: SCHLAGE D10S US26D 1 CLOSER: NORTON 8400 US26D COVER 1 DOOR STOP: IVES 240F 1 KICKPLATE v, _ �- D 4 DETAIL 1 1 /2" =1'-0" @ PARTITION HEAD MANAGER'S DESK AND ABOVE THE NATIONAL MESSAGE, STAINLESS STEEL 3 SHELF UNIT WALL MOUNTED @ 60" A.F.F. WITH HEAVY DUTY SHELF BRACKET (SH-2) PROVIDE BLOCKING AS REQUIRED KV SUPPORT FINISH: CHROME ELECTRICAL OUTLETS PLANS ®44" A.F.F. P-LAM COUNTERTOP WITH 4" HIGH P-LAM o BACKSPLASH. i 2'— ' � Q D V BLOCKING DETAIL D 11 HARDWARE 2X6 BLOCKING 2-No. 8xl-1/2" WD. SCREWS @ 24" C.C. 16GA. DEEP LEG TRACK /ElPER - - - - - --- - -- - -- - - - BATT INSULATION (NOT SHOWN FOR F CLARITY) 1 1 /2" X 1 1 /2" 18 GA. CLIP No. 10 SMS EA. SIDE AT STUD TO HORIZ. TRACK, TYP. 1 3/4' HEAD ABOVE --\ G3 CEILING, CR LAURENCE A-4 HClWH240 (OR EQUAL) ( I CEILING CLG-1® 10'-0" AFF. ` CEILING CLG-1 ® 10'-0" A.F.F. CORNER OF GYP. BD. WALL BEYOND I i 1/2" TEMPERED ( GLASS I VIRTUAL QUEUE. I SINGLE PLASMA CORNER OF GYP. BD. SCREEN WALL BEYOND 1 /2" TEMPERED GLASS _ 6"x24" CUT—OUTS F3 � f y v M 4 rJ 1 /4" = 1'-0" NONE SCHEDULE REF PRODUCT DESCRIPTION NOTES BC BREAK COUNTER - 48"L X 25"W X 34"H CH-1 CHAIR HERMAN MILLER EN711ASNBUBCBK - PLAN CHECK COMMENTS 1 20 /05 CH-3 CUSTOMER CHAIR SOLUTION TABLE TBD - CH-7 STACKABLE CHAIR LIMRICK LMSGBKBK - 1 ISSUED FOR PERMIT AND BID 1 7 04 No. Revisions /Submissions Date CFP COPY PRINTER FAX — — CARRILLO FC-1 FILE CABINET HON 500 SERIES 25' 3 DRAWER — LF-1 LATERAL FILE TBD — MIC MICROWAVE 1 CUBIC FOOT MICROWAVE OVEN WHITE G.C. TO PURCHASE AND INSTALL 400 ALLOWANCE TOTAL FOR MICROWAVE m 16GA. HORIZ. TRACK FREE TO EXISTING MOVE VERT. IN FRAMING DEEP LEG TRACK, 25 GA. MTL. STUD, TYP. REFER TO WALL LEGEND FOR SIZE (20 GA. MTL. STUD PERPENDICULAR WHERE INDICATED) NOTE: FASTNERS TO COMPLY WITH ICBO ER-1639 OR ER-2388 WALL ASSEMBLY STUDS TO COMPLY WITH U.L. DESIGN No. U465 ICBO ER-4943 CONTINUOUS ALUMINUM = BLOCKING AT WALL AS REQUIRED � P-LAM SUPPORT LEGS AT 4'-0" O.C.o (MAX.)( N P-LAM END PANEL WHEN WORK SURFACE DOES NOT MEET WALL PROVIDE 2 LEVELING FEET PER SUPPORT FIN. FLR. 8" 3" I A-4 I �'' PLASTIC LAMINATE MATCH FIXTURE 34" AFF. B.O. OPENING WOOD 2X PLASTIC LAMINATE MATCH FIXTURE. —TECH. - BENCH BRACE AS REQUIRED WALL TYPE A. SIM. I _ —_ _ GYP. BD. P-1 z BASE. SEE FINISH I `V FIN. FLR. A R C H I T E C T U R A L G R O UP I N C J. Steven Carrillo 11231 Gold Express Dr. A.I.A. C11.222 suite 103 Gold266-6000A 95670 FAX 266-6006 THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED To ANY THIRD PARTY WITHOUT FIRST OBTAINING THE FINAL EXPRESS OR TOTTEN BE USED FIORION FROM THE CONSTTRUCTION NTILECT, THE SIGNED BY THE ING IS ARCHI ARCHITECT. REF UNDER COUNTER REFRIGERATOR 6-8 CU. FT. REFRIGERATOR AND REFRIGERATOR S SAFE 12"W X 48"L X 31"H BF3416 G.C. TO SECURE SAFE TO FLOOR SH-2 WALL MOUNT SHELF — 5'-0" A.F.F. TO LOWEST SHELF SH-5 SUPPLY SHELF UNIT — — SH-6 LIGHT DUTY SHELF — — SH-7 LIGHT DUTY SHELF — — SH-8 LIGHT DUTY SHELF Drawing Title WALL TYPES SCHEDULES AV DETAILS T-1 MANAGERS DESK NATIONAL 10-306OP461 59,5 D X 28' L T-2 CAFE TABLE HERMAN MILLER ET102LHFBU 36 DIA. Q TB TECH BENCH TBDTBD WS-1 WORK 48'L X 25"W X 34'H VCR VCR SECURITY REC. DEVICE - Seal cj�� ARC,S, - N Cq,�rT `- `� �� , a ,'� � .. d. C11, 2 REN. 9,/5 4� 0 ®F AL (drawn ' TCB Checked NSH IT/AN IT LAN PHONEBCARD - NEW 4' X 4' X 3 4" FIRE -RATED PLYWOOD BACKBOARD INSTALLED BY G.C. - - Project No. 04139.66 KIT FIRST AID - PROVIDED BY OWNER INSTALLED BY G.C. @ 36" A.F.F. ADJACENT TO BREAK COUNTER PS PLASMA SCREEN - - Date 1-7-05 A! PARTITION @ ROOF DECK A4 DETAIL A6 DETAIL A8 ° FIXTURE AND FURNITURE SCHEDULE ��� Scale FULL @WORK CNTR. & BRK. CNTR. NTS TECH BENCH NONE Drawing No. A_ n 1 2 3 4 5 6 7 8 9 10 11 12 - __$ % -_ — 2 3 4 5 6 1 7 8 1 9 1 10 1 11 12 NEW SIGNAGE TO BE MANUFACTURED AND INSTALLED BY SPRINT VENDOR (N.I.C,). VENDOR TO COORDINATE WITH LANDLORD AND SPRINT NCM FOR EXACT SPECIFICATIONS OF SIGNAGE. ELECTRICAL CONNECTIONS PROVIDED BY G.C. 1III!II!II!IEW m■ GENERAL CONTRACTOR TO PROVIDE ADDRESS NUMERALS ABOVE ENTRY DOOR PER CENTER STANDARDS AND LOCAL CODE REQUIREMENTS. (3" HIGH NUMBERS PLAINLY VISIBLE FROM OUTSIDE OF THE SUITE.) Al ..IIIIIIIIII. STOREFRONT ELEVATION (SOUTHWEST) NO WORK, FOR REFERENCE ONLY IIIIIIIIIiiiiii0■ 0 I 0 o� RE 1/2" TEMPERED A6 GLASS WALL A-4 CLG-1 CESSED GLASS AT HEAD PLASMA SCREEN 5-1/2" TEMPERED GLASS WALL CLG-1 1/2„ �r CLG-1 » 1/2" 4'-0 BRAND GRAPHIC 1 2" TEMPERED EQ 1'—C EQ (BEYON 3"O CUT—OUT-TYP. GLASS WALL %, P-1 CO EQ EQ At, - BEVELED P-1 CUT OUT. TECH. FINISH BEYOND ( ) __ __._ __ ___ __ _ FLOOR. _ _ -- —_ _- -' -�— I VB-1 BEVELED VB-1 "' M UT OUT. IP-4 WOOD VB-1 P_ EQUAL 12'-0" EQUAL TECH ROOM (BEYOND) ELEVATION NOTE — EXTERIOR SIGNAGE NOT IN CONTRACT: 1. ALL SIGNS ARE SUBJECT TO LANDLORD'S WRITTEN APPROVAL ON PREPARED SHOP DRAWINGS AND SPECIFICATIONS FROM A SIGN MANUFACTURER PRIOR TO THE SIGN FABRICATION. 2. SIGN SHOP DRAWING SUBMITTAL SHALL INCLUDE AN ELEVATION OF THE STOREFRONT WITH SIGNAGE COMPLETELY DIMENSIONED AND DRAWN TO A SCALE OF 1/2" = 1'-0", SECTION THROUGH LETTERS AND ATTACHMENT ASSEMBLY, AND ALL MATERIALS AND COLORS USED. 3. SUBMIT 2 DRAWINGS TO LANDLORD'S TENANT COORDINATOR FOR REVIEW AND APPROVAL. 4. ENTIRE STOREFRONT AND FACADE TO BE PRESSURE WASHED CLEAN. 5. DAMAGED NEW FINISH ON EXTERIOR WALLS TO BE REPLACED WITH FINISH TO MATCH EXISTING. G.C. TO SUBMIT SAMPLE OF NEW AND EXISTING BLOCK FINISH TO ARCHITECT FOR APPROVAL PRIOR TO CONSTRUCTION. 6. NEW SIGNAGE ON PYLON SIGN. SPRINT VENDOR TO COORDINATE WITH LANDLORD AND SPRINT NCM FOR EXACT SPECIFICATIONS OF SIGNAGE. FW NOTE: GRAPHIC SYMBOLS LEGEND LOCATED A7/G-3 2—No. 10 SMS EA. STUD FASTEN TO EXISTING CONSTRUCTION PER CODE EXISTING EXTERIOR WALL 2—No. 10 SMS EA. FLANGE TRACK FASTEN TO EXISTING CONSTRUCTION PER CODE EXISTING STOREFRONT, SEE ELEVATIONS. CONTINUOUS MTL. CHANNEL RUNNER, TYP, HORIZONTAL FACE OF GYP. BD. SOFFIT PAINTED P-3 2—No. 10 SMS EA.. STUD FASTEN TO EXISTING CONSTRUCTION PER CODE EXISTING EXTERIOR WALL 2—No. 10 SMS EA. FLANGE TRACK FASTEN TO EXISTING CONSTRUCTION PER CODE EXISTING STOREFRONT, SEE ELEVATIONS. CONTINUOUS MTL. CHANNEL RUNNER, TYP. HORIZONTAL FACE OF GYP. BD. SOFFIT PAINTED P-3 PARALLEL TO ROOF STRUCTURE HANGER NOT TO BE SPACED GREATER THAN 54" O.C. 3-5/8" 24 GA. MTL. STUD KICKER 0 45' O.C. 3-5/8' 20 GA. MTL. STUD ® 24' O.C. 5/8" GYP. BD. TO 6" ABOVE CEILING +10'-0" A.F.F. 3—No. 10 SMS 0 EA. STUD, TYP. STOREFRONT HEIGHT Jk FIELD VERIFY TYP. OVER IRDANT 'E DEPTH AND LENGHT OF SOFFIT HANGER NOT TO BE SPACED GREATER THAN 54" O.C. 3-5/5' 24 GA, MTL, STUD KICKER ® 48" O.C. 3-5/8" 20 GA. MTL. STUD @ 24" O.C. 5/8" GYP. BD. TO 6" ABOVE CEILING +10'-0" A.F.F. qV 3—No. 10 SMS EA. STU D, TYP. STOREFRONT HEIGHT +8'-0" A.F.F FIELD VERIFY TYP. OVER �RDANT ".,,,ZE DEPTH , AND LENGHT OF SOFFIT -A&L.I.SP114put mr 1446 SANTA A A, CA SOUTH COAST PLAZA 3611 SOUTH BRISTOL ST. SUITE B SANTA ANA, CA 92704 PROJECT TEAM OWNER'S PROJECT MANAGER TRAMMELL CROW SPRINT PCS PROJECT MANAGER 6100 SPRINT PARKWAY Mailstop: KSOPHKO410-4A554 OVERLAND PARK, KS 66251 PHONE; (913) 315-5110 CONTACT: RON GERARD ron.d.gerard®moil.sprint.com ARCHITECT CARRILLO ARCHITECTURAL GROUP, INC. 11231 GOLD EXPRESS DR., SUITE 103 GOLD RIVER, CA 95670 PHONE: (916) 266-6000 FAX: (916) 266-6006 CONTACT: NATE HENINGER nateheninger®carrilloog.com MEP ENGINEERS HENDERSON ENGINEERS 8325 LENEXA DRIVE, SUITE 400 LENEXA, KS 66214 PHONE: (913) 307-5464 FAX: (913) 307-5400 CONTACT: TREVOR JONES trevor.jones@hendersonengineers.com LANDLORD INVESTCORP / ORANGE BRISTOL, LP 280 PARK AVE, 36TH FLOOR NEW YORK, NY 10017 PHONE: (212) 577-1414 CONTACT: HEATHER MUTTERPERL /� PLAN CHECK COMMENTS 1 /20/05 (1 ISSUED FOR PERMIT AND BID 1 /7/04 No. Revisions / Submissions Date CARRILL® ARCHITECTURALGROUPINC J. Steven Carrillo 11231 Gold Express Dr. A.I.A. C11,222 Suite 103 Gold River, CA 95670 916 266-6000 FAX 266-6006 THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED - HEREBY RIGHTS IN BE REPRODUCED, NOR ARE THEY OBTAINING THE DRAWING IS NOT BY THE ARCHITECT, Drawing Title PERPENDICULAR TO ROOF STRUCTURE ELEVATIONS NOTE: NOTE: - AND SECTIONS FASTNERS TO COMPLY WITH 1. 2' X 2' METAL ACCESS PANEL, REFER TO REFLECTED raven Seal Checked ICBO ER-1639 OR ER-2388 CEILING PLAN A-3 FOR LOCATION AND DIMINSIONS. ff ARC, TCB NSH STUDS TO COMPLY WITH 2. INSTALL NEW SOFFIT AT TOP OF EXISTING STOREFRONT S ICBO ER-4943. SYSTEM. 770 Cq�, rT Project No. 04139.66 c � � r b ID 14 Date AlNOTE• NOTE• �,... 1-7-05 AI INTERIOR ELEVATION GRAPHIC SYMBOLS LEGEND A8 SOFFIT SECTION GRAPHIC SYMBOLS LEGEND to `C 1 1 - 2 `q Scale LOCATED A7/G-3 LOCATED A7/G-3 y r REN. 05 4� FULL 4" —1 ,—O" �� — ,— " ��F(�P.�-`�® Drawing No. 1/ GLASS WALE AT BACK OF SALES 101 1 1 o A-5 1 1 2 1 3 4 1 5 6 7 8 9 10 1 11 12 2 3 4 5 6 7 Fro 12 E IU [nI 11111—mi I U IQ 2 3 EDULE EXTERIOR _D D OF ETE SLAB UNDERCARPET POWER LINES UNDERCARPET COMMUNICATION LINES I 1 T _. __! � �._ T i I ' EQ. EQ, � EQ. I i I C�f I ALL TURNS TO BE I II I --�— ALL TURNS TO BE MADE II I I MADE AT 90' I \\ \ I AT 90' WITH 10" MIN. RADIUS i EQ. II EQ. I I i i EQ. II EQ. ! ! LINE OF CARPET TILE LINE OF CARPET TILE 36" X 36" TYPICAL. 36" X 36" TYPICAL. MANUFACTURER: AMP CONNECT — UL #373212; FCC FITTING #373213 NOTE: REFER TO MANUFACTURER SPECIFICATIONS FOR ADDITIONAL INFORMATION. NOTE: 1. SEE UNDERCARPET DIMENSION PLAN ON ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. G.C. IS RESPONSIBLE FOR ALL COORDINATION OF UNDERCARPET WIRING AND CARPET TILE. NO RAISED CARPET TILE SEAMS WILL BE ACCEPTED. NOTE: GENERAL CONTRACTOR INSTALL WEATHER HEAD AS + AS POSSIBLE TO I.T, EQUIPM RACK. COORDINATE EXACT LOCATION AS REQUIRED IN F TO AVOID ANY EXISTING ROO TOP ITEMS. 1" WEATHER HEAD 1" RIGID GALV. CONDUIT PITCH POCKET OR FLASHING COMPATABLE WITH ROOF EXISTING ROOFING EXISTING ROOF DECK EXISTING STRUCTURE 1" X 1" UNISTRUT SUPPORT STEEL STRAP OR 1/4" ALL THREAD KICKERS TO UNISTRUT 4 PLACES TYPICAL 1" CLAMP NYLON BUSHING LOW VOLTAGE BY DMX MUSIC No, 12 GA. VERTICAL HANGER WIRE @ 48" O.C. No. 12 GA. SPLAY WIRE (4) BRACING IN PLAN OF EA. RUNNER. VERTICAL ANGLE=45 DEGREES DSS TEE @ 24" O.C. MAIN RUNNER @48" O.C. 6'-0" MAX. G9 BRACING Nrs SEISMIC BRACING NTS SEISMIC BRACING POINTS SHALL BE AT 12'-0" O.C. IN BOTH DIRECTIONS WITH THE FIRST POINT NO MORE THAN 6'-0" FROM EACH WALL. LAG BOLT (TYP.) BLOCKING (E) FRAMING ANGLE 1-1/2" X 1-1/2' X 18 GA. 1 /4" DIA. BOLT TOP BOTTOM, SPLIT EMT , , FER TO COMPRESSION POST SCHEDULE. EXTENDED TUBE SHALL BE TIGHT TO CEILING AND ROOF STRUCTURE. TUBES SHALL OVERLAP 4" MIN. IN FULLY EXTENDED POSITION. G 11 DETAIL NTs POST CONNECTION No, 12 GA. VERTICAL HANGER @ 48" O.C. HOLD—DOWN CLIP MAIN RUNNER OR CROSS RUNNERS ATTACHED TO WALL ACOUSTICAL PANEL LAY —IN CEILING EDGE TRIM NOTE: GRAPHIC SYMBOLS LEGEND LOCATED A7/G-3 NO. 12 VERTICAL WIRE HANGER *LEVEL CEILING GRID PRIOR TO SETTING TUBE EXISTING UNDERSIDE OF FLOOR OR ROOF STRUCTURE ABOVE MEMBER "a" NO. 12 GA. SPLAY WIRE (4) BRACING IN PLANE *OF EA. RUNNER. VERTICAL ANGLE=45 DEGREES MEMBER "b" DRILL 3/32" HOLE AND INSTALL 1/8" BOLT & LOCKING NUT EMT SLEEVE.REFER TO COMPRESSION POST SCHEDULE. EXTENDED TUBE SHALL BE TIGHT TO CEILING AND ROOF STRUCTURE. TUBES SHALL OVERLAP 4' MIN. IN FULLY EXTENDED POSITION Z. CROSS TEE ® 24" O.C. COMPRESSION POST SCHEDULE MAX. LENGTH MEMBER "a" MEMBER "b" 4'-0" 1 /2" 0 EMT 3/4" 0 EMT 5'-2" 3/4" 0 EMT 1" 0 EMT 6'-6" 1" 0 EMT 1-1/4!' 0 EMT 8'-6" 1-1/4' 0 EMT 1-1/2" 0 EMT 9'-10" 1-1/2" 0 EMT 2" 0 EMT 12'-7" 2" 0 EMT 2-1/2" 0 EMT A5 DETAIL GRAPHIC SYMBOLS LEGEND A9 COMPRESSION STRUT LOCATED A7/G-3 3/4' = l'—Y' WEATHERHEAD FOR SATELLITE DISH CONNECTION NTs 4 5 I 6 7 8 9 10 _NOTE: GRAPHIC SYMBOLS LEGEND LOCATED A7/G-3 12 SP-14mt 1446 SANTA ANA, CA SOUTH COAST PLAZA 3611 SOUTH BRISTOL ST. SUITE B SANTA ANA, CA 92704 PROJECT TEAM OWNER'S PROJECT MANAGER TRAMMELL CROW SPRINT PCS PROJECT MANAGER 6100 SPRINT PARKWAY Mailstop: KSOPHKO410-4A554 OVERLAND PARK, KS 66251 PHONE; (913) 315-5110 CONTACT: RON GERARD ron,d.gerard@mail.sprint.com ARCHITECT CARRILLO ARCHITECTURAL GROUP, INC. 11231 GOLD EXPRESS DR., SUITE 103 GOLD RIVER, CA 95670 PHONE: (916) 266-6000 FAX: (916) 266-6006 CONTACT: NATE HENINGER noteheninger®carrilloag.com MEP ENGINEERS HENDERSON ENGINEERS 8325 LENEXA DRIVE, SUITE 400 LENEXA, KS 66214 PHONE: (913) 307-5464 FAX: (913) 307-5400 CONTACT: TREVOR JONES trevor.jones@hendersonengineers.com LANDLORD INVESTCORP / ORANGE BRISTOL, LP 280 PARK AVE, 36TH FLOOR NEW YORK, NY 10017 PHONE: (212) 577-1414 CONTACT: HEATHER MUTTERPERL /1\ PLAN CHECK COMMENTS 1 /20/05 0 ISSUED FOR PERMIT AND BID 1 /7/04 No. Revisions / Submissions Date CARRILLO ARCHITECTURALGROUPINC J. Steven Carrillo 11231 Gold Express Dr, A.I.A. C11.222 Suite 103 x Gold River, CA 95670 916 266-6000 FAX 266-6006 THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE DRAWING IS NOT FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT. Drawing Title DETAILS Seal '' rown Checked R TCB NSH CA fA Project No. 04139.66 f O Date /9 1-7-05 No: C1 t�,222 `Q Scale y REN.0105+ �� FULL ®F Ct`�o Drawing No. A— 6 1 2 3 4 5 6 7 8 9 10 11 12 I* GENERAL CONSTRUCTION NOTES PART 2 - EXISTING CONDITIONS NOTES SECTION 01100 -SUMMARY SECTION 01600 •- PRODUCT REQUIREMENTS PART 1 - GENERAL NOTES 2.1 PROTECT FINISH MATERIALS AND EXISTING EQUIPMENT IN OR ADJACENT TO AREAS OF WORK. REPAIR OR REPLACE PART 1 - GENERAL 1.1 WORK COVERED BY CONTRACT DOCUMENTS PART 1 - GENERAL 1.1 SUMMARY -A&. _M1111111,911ilk-da spfin t FINISHES AND EQUIPMENT DAMAGED DURING CONSTRUCTION. A. THE WORK CONSISTS OF THE FOLLOWING: A. THIS SECTION INCLUDES ADMINISTRATIVE AND PROCEDURAL REQUIREMENTS FOR SELECTION OF PRODUCTS FOR USE IN 4vr 1.1 ALL WORK SHALL CONFORM WITH THE APPLICABLE BUILDING CODES, REGULATIONS, OCCUPANCY PERMITS AND 2.2 WHERE WALLS, CEILINGS OR FLOORS ARE PATCHED, EXTENDED OR REPAIRED, MATCH EXISTING MATERIAL, SIZE, 1, THE WORK INCLUDES DEMOLITION AND REMODELING OF A LEASED FACILITY (THE PROJECT SITE). THE PROJECT; PRODUCT DELIVERY, STORAGE, AND HANDLING; MANUFACTURERS' STANDARD WARRANTIES ON PRODUCTS; SPECIAL ORDINANCES. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ORDERS OF ANY PUBLIC AUTHORITY PATTERN, TEXTURE & COLOR UNLESS INDICATED OTHERWISE. CONTRACTOR SHALL PERFORM ALL WORK REQUIRED FOR COMPLETION OF THE PROJECT. WARRANTIES; PRODUCT SUBSTITUTIONS; AND COMPARABLE PRODUCTS. BEARING ON THE PERFORMANCE OF THE WORK. THE CONTRACTOR SHALL APPLY FOR, OBTAIN AND PAY FOR ALL 2.3 PROTECT ALL EXISTING CONDITIONS TO REMAIN. ALL CONSTRUCTION/CONDITION WHICH IS DAMAGED DUE TO 1.2 WORK UNDER OTHER CONTRACTS 1.2 DEFINITIONS 1 4 6 S A A A A A R. SHALL BE PATCHED TO MATCH ADJACENT CONSTRUCTION. A. GENERAL: COOPERATE FULLY WITH SEPARATE CONTRACTORS SO WORK ON THOSE CONTRACTS MAY BE CARRIED OUT A. PRODUCTS: ITEMS PURCHASED FOR INCORPORATING INTO THE WORK, WHETHER PURCHASED FOR PROJECT OR TAKEN FROM I tl�t I THE EVENT OF A CONFLICT BETWEEN THE CONSTRUCTION DOCUMENTS AND AN APPLICABLE CODE, CONTRACTOR SHALL IMMEDIATELY NOTIFY THE TENANT AND THE ARCHITECT FOR DIRECTION AND RESOLUTION, FAILURE TO NOTIFIY 2A IF NECESSARY TO ACHIEVE HOMOGENEOUS FINISH, REFINISH/REPLACE FINISH MATERIALS TO FIRST NATURAL EDGE OR SMOOTHLY, WITHOUT INTERFERING WITH OR DELAYING WORK UNDER THIS CONTRACT. COORDINATE THE WORK OF THIS PREVIOUSLY PURCHASED STOCK. THE TERM "PRODUCT" INCLUDES THE TERMS "MATERIAL," "EQUIPMENT," "SYSTEM," AND /� c SOUTH C COAST T PLAZA CONTRACT WITH WORK PERFORMED UNDER SEPARATE CONTRACTS, TERMS OF SIMILAR INTENT. EITHER OF THESE PARTIES PRIOR TO COMMENCEMENT OF THE WORK, SHALL MAKE THE CONTRACTOR RESPONSIBLE CORNER. CONTRACTOR SHALL TAKE PRECAUTIONS TO MAINTAIN & PROTECT EXISTING SYSTEMS AND FINISHES WHICH 1.3 USE OF PREMISES 1. NAMED PRODUCTS: ITEMS IDENTIFIED BY MANUFACTURER'S PRODUCT NAME, INCLUDING MAKE OR MODEL NUMBER OR FOR ANY CORRECTIVE MEASURES NEEDED TO BRING THE PROBLEM INTO PROPER CONFORMANCE, WITHOUT ARE TO REMAIN. ANY DAMAGES TO SUCH SYSTEMS & FINISHES SHALL BE IMMEDIATELY REPAIRED IN A MANNER A. GENERAL: CONTRACTOR SHALL HAVE FULL USE OF PREMISES FOR CONSTRUCTION OPERATIONS INCLUDING USE OF OTHER DESIGNATION SHOWN OR LISTED IN MANUFACTURER'S PUBLISHED PRODUCTLITERATURE,T THAT IS CURRENT AS 361 SOUTH BRISTOL ST. ADDITIONAL COSTS OR CHARGES TO THE TENANT OR THE ARCHITECT. PROVIDE COPIES OF ALL TRANSACTIONS TO TENANT. ACCEPTABLE TO THE NCM. IF SATISFACTORY REPAIRS CANNOT BE MADE, CONTRACTOR SHALL REPLACE SYSTEMSJECT AND FINISHES WITH LIKE NEW QUALITY CONSTRUCTION ACCEPTABLE TO THE NCM. ALL REPAIRS AND REPLACEMENT EWORK DURLN S USE FO FPROJECTEMISES S LIMITED ONLY BY OWNER'S RIGHT RCONTRACTORS CONR DATE OF TPRODHE UUCT: SUITE B TOOPERFORM R TO RETANCONSTRUCTIOTHER PORTIONS 2 COMPARABLEOF PRODUCTITH T IS DEMONSTRATED AND APPROVED THROUGH SUBMITTAL PROCESS, OR WHERE 1.2 CONTRACTOR SHALL PROVIDE & MAINTAIN A RECLINED AS -BUILT CONSTRUCTION DOCUMENT SET AT THE SITE. COSTS SHALL BE THE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR. WHERE WALLS, EQUIPMENT OR OTHER COMPONENTS ARE REMOVED, PATCH AND REPAIR REMAINING SURFACES TO MATCH ADJACENT. 1.4 OWNER'S OCCUPANCY REQUIREMENTS INDICATED AS A PRODUCT SUBSTITUTION, TO HAVE THE INDICATED QUALITIES RELATED TO TYPE, FUNCTION, DIMENSION, SANTA ANA, CA 92704 1.3 THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR, AND HAVE CONTROL OVER, ALL CONSTRUCTION MEANS, A. OWNER OCCUPANCY OF COMPLETED AREAS OF CONSTRUCTION: OWNER RESERVES THE RIGHT TO OCCUPY AND TO PLACE AND INSTALL IN-SERVICE PERFORMANCE, PHYSICAL PROPERTIES, APPEARANCE, AND OTHER CHARACTERISTICS THAT EQUAL OR TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS IF THE WORK REQUIRED BY THE 2.5 ANY EXISTING BASE BUILDING WINDOW MULLION SYSTEM DAMAGED DURING DEMOLITION TO BE PATCHED AND EQUIPMENT IN COMPLETED AREAS OF BUILDING, BEFORE SUBSTANTIAL COMPLETION, PROVIDED SUCH EXCEED THOSE OF SPECIFIED PRODUCT. CONTRACT DOCUMENTS. REPAIRED TO ORIGINAL CONDITION. OCCUPANCY DOES NOT INTERFERE WITH COMPLETION OF THE WORK. SUCH PLACEMENT OF EQUIPMENT AND PARTIAL B. SUBSTITUTIONS: CHANGES IN PRODUCTS, MATERIALS, EQUIPMENT, AND METHODS OF CONSTRUCTION FROM THOSE REQUIRED PROJECT TEAM 2.6 WHERE DIRECTED BY TENANT OR OWNER, PROVIDE TEMPORARY BARRICADES OR OTHER FORMS OF PROTECTION SUCH OCCUPANCY SHALL NOT CONSTITUTE ACCEPTANCE OF THE TOTAL WORK. BY THE CONTRACT DOCUMENTS AND PROPOSED BY CONTRACTOR. OWNER'S PROJECT MANAGER 1.4 NO EQUIPMENT, MATERIALS, OR VEHICLES ARE TO BE STORED OR PARKED ON AREAS NOT WITHIN THE AREAS AS A DUST PROOF PARTITIONS TO ISOLATE AREAS OF NOISE OR DIRT GENERATED BY CONSTRUCTION. DUST PROOF 1.3 SUBMITTALS INDICATED AS BEING DEMOLISHED ON THE DRAWINGS. IF AREAS ARE DISTRUBED OR DAMAGED, THE CONTRACTOR IS PARTITIONS MAY BE ANY COMBINATION OF WOOD STUDS, POLYETHYLENE, PLYWOOD & GYPSUM BOARD AS REQUIRED SECTION 01330 -SUBMITTAL PROCEDURES A. SUBSTITUTION REQUESTS: SUBMIT THREE COPIES OF EACH REQUEST FOR CONSIDERATION. IDENTIFY PRODUCT OR TRAMMELL CROW RESPONSIBLE FOR REPLACEMENT AT CONTRACTORS EXPENSE. TO PROTECT THE PUBLIC, OWNER'S PERSONNEL AND EQUIPMENT REMAINING FROM CONSTRUCTION ACTIVITY IN PART 1 - GENERAL FABRICATION OR INSTALLATION METHOD TO BE REPLACED. INCLUDE SPECIFICATION SECTION NUMBER AND TITLE AND 1.5 CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE SAFETY OF CONSTRUCTION PERSONNEL AND AUTHORIZED CONSTRUCTION AREA. 1.1 SUMMARY DRAWING NUMBERS AND TITLES. VISITORS. A. THIS SECTION INCLUDES ADMINISTRATIVE AND PROCEDURAL REQUIREMENTS FOR SUBMITTING SHOP DRAWINGS, PRODUCT B. COMPARABLE PRODUCT REQUESTS: SUBMIT THREE COPIES OF EACH REQUEST FOR CONSIDERATION. IDENTIFY PRODUCT OR SPRINT PCS PROJECT MANAGER = 2.7 THE GENERAL CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL WORK WITH THE NCM AND THE BASE BUILDING DATA, SAMPLES, AND OTHER SUBMITTALS. FABRICATION OR INSTALLATION METHOD TO BE REPLACED. INCLUDE SPECIFICATION SECTION NUMBER AND TITLE AND 6100 SPRINT PARKWAY 1.6 SCOPE OF WORK OF ALL TRADES IS TO INCLUDE ALL MATERIALS AND LABOR AS REQUIRED TO TOTALLY COMPLETE THE PROJECT FROM INTERFACE WITH EXISTING CONSTRUCTION CONFIGURATION INDICATED OWNER. THE WORK OF ALL TRADES AND VENDORS IS TO BE COORDINATED BY THE GENERAL CONTRACTOR. 1.2 DEFINITIONS DRAWING NUMBERS AND TITLES. Mailstop: KSOPHKO410-4A554 THROUGH AS IN THE CONSTRUCTION DOCUMENTS. ALL WORK SHALL BE COMPLETE AND FUNCTIONAL, CONSISTENT WITH THE DESIGN 2.8 THE OWNER WILL MAINTAIN DAILY OPERATIONS OF THE FACILITY DURING CONSTRUCTION. THE CONTRACTOR WILL A. ACTION SUBMITTALS: WRITTEN AND GRAPHIC INFORMATION THAT REQUIRES ARCHITECT'S RESPONSIVE ACTION. 1.4 QUALITY ASSURANCE A. COMPATIBILITY OF OPTIONS: IF CONTRACTOR IS GIVEN OPTION OF SELECTING BETWEEN TWO OR MORE PRODUCTS FOR USE OVERLAND PARK KS 66251 INTENT AS EXPRESSED IN THSE DOCUMENTS, WHETHER SPECIFICALLY ADDRESSED IN THESE DOCUMENTS OR NOT. COORDINATE WORK AFFECTING DAILY OPERATIONS W/OWNER'S REPRESENTATIVE. AT NO TIME IS THE CONTRACTOR'S B. INFORMATIONAL SUBMITTALS: WRITTEN INFORMATION THAT DOES NOT REQUIRE ARCHITECT'S RESPONSIVE ACTION. SUBMITTALS MAY BE REJECTED FOR NOT COMPLYING WITH REQUIREMENTS. ON PROJECT, PRODUCT SELECTED SHALL BE COMPATIBLE WITH PRODUCTS PREVIOUSLY SELECTED, EVEN IF PREVIOUSLY PHONE; (913) 315-5110 ANY QUESTIONS CONCERNING THE COMPLETENESS OF THE WORK SHALL BE ADDRESSED TO THE NCM. ACTIVITY TO PREVENT DAILY OPERATIONS OF FACILITY. 1.3 SUBMITTAL PROCEDURES PRODUCTS WERE SELECTED PRODUALSO OPTIONS. CONTACT: RON GERARD ron.d.gerard0mail. sprint. com 1.7 ALL WORK SHALL BE PERFORMED BY THE GENERAL CONTRACTOR UNLESS OTHERWISE NOTED. ALL REFERENCES TO 2.9 CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO MINIMIZE DISRUPTION OF EXISTING BUILDING FUNCTIONS A. COORDINATION: COORDINATE PREPARATION AND PROCESSING OF SUBMITTALS WITH PERFORMANCE OF CONSTRUCTION 1.5 PRODUCT DELIVERY, STORAGE, AND HANDLING THE "CONTRACTOR" INCLUDE THE GENERAL CONTRACTOR AND THE SUBCONTRACTORS. DURING CONSTRUCTION. ANY MAJOR DISRUPTIVE WORK SHOULD BE DONE AFTER BUSINESS HOURS. COORDINATE ACTIVITIES. A. DELIVER, STORE, AND HANDLE PRODUCTS USING MEANS AND METHODS THAT WILL PREVENT DAMAGE, DETERIORATION, AND 1.8 THE GENERAL CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS RECEIVE COMPLETE SETS OF WORKING DRAWINGS WITH BUILDING OWNER AND NCM. DISRUPTIONS INCLUDE BUT ARE NOT LIMITED TO EXCESSIVE NOISE. 1. COORDINATE EACH SUBMITTAL WITH FABRICATION, PURCHASING, TESTING, DELIVERY, OTHER SUBMITTALS, AND LOSS, INCLUDING THEFT. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. ARCHITECT COORDINATION OF THEIR WORK AND DESCRIPTION OF SCOPE. THE GENERAL CONTRACTOR SHALL ASSUME FULL 2.10 IT IS THE INTENT OF THE DRAWINGS THAT EXISTING CONSTRUCTION TAKE PRECEDENCE OVER THE DIMENSIONED RELATED ACTIVITIES THAT REQUIRE SEQUENTIAL ACTIVITY. B. DELIVERY AND HANDLING: CARRILLO ARCHITECTURAL GROUP, INC.ANDLING RESPONSIBILITY FOR COORDINATION OF THE WORK WHEN COMPLETE SETS ARE NOT MADE AVAILABLE TO PLANS. EXISTING DIMENSIONS AND CONDITIONS SHOWN ON THESE DRAWINGS ARE BASED ON THE OWNER'S RECORD B. PROCESSING TIME: ALLOW ENOUGH TIME FOR SUBMITTAL REVIEW, INCLUDING TIME FOR RESUBMITTALS, AS FOLLOWS. 1. SCHEDULE DELIVERY TO MINIMIZE LONG - TERM STORAGE AT PROJECT SITE AND TO PREVENT OVERCROWDING OF SUBCONTRACTORS. DOCUMENTS AND FIELD MEASUREMENTS IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ACTUAL TIME FOR REVIEW SHALL COMMENCE ON ARCHITECT'S RECEIPT OF SUBMITTAL. NO EXTENSION OF THE CONTRACT TIME CONSTRUCTION SPACES. 11231 GOLD EXPRESS DR., SUITE 103 1.9 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ACTS AND OMISSIONS OF THE CONTRACTOR'S EMPLOYEES, DIMENSIONS AND CONDITIONS. WHERE ACTUAL CONDITIONS OR DIMENSIONS VARY FROM THOSE SHOWN, CONTRACTOR WILL BE AUTHORIZED BECAUSE OF FAILURE TO TRANSMIT SUBMITTALS ENOUGH IN ADVANCE OF THE WORK TO PERMIT 2. COORDINATE DELIVERY WITH INSTALLATION TIME TO ENSURE MINIMUM HOLDING TIME FOR ITEMS THAT ARE FLAMMABLE, HAZARDOUS, EASILY DAMAGED, OR SENSITIVE TO DETERIORATION, THEFT, AND OTHER LOSSES. GOLD RIVER CA 95670 SUBCONTRACTORS AND THEIR AGENTS AND EMPLOYEES, AND ANY OTHER PERSONS PERFORMING ANY OF THE WORK SHALL RECORD DIFFERENCES PRIOR TO PROCEEDING WITH CONSTRUCTION AND NOTIFY NCM OF DISCREPANCIES WITHIN 24 HOURS. THESE RECORDS WILL BE USED TO DETERMINE ADJUSTMENTS TO THE CONTRACT. PROCESSING, INCLUDING RESUBMITTALS. 1. INITIAL REVIEW: ALLOW [5] FIVE DAYS FOR INITIAL REVIEW OF EACH SUBMITTAL. ALLOW ADDITIONAL TIME IF . 3DELIVER PRODUCTS TO PROJECT SITE IN AN UNDAMAGED CONDITION IN MANUFACTURERS ORIGINAL SEALED CONTAINER PHONE: (916) 266- 6000 UNDER A CONTRACT WITH THE CONTRACTOR. COORDINATION WITH SUBSEQUENT SUBMITTALS IS REQUIRED. ARCHITECT WILL ADVISE CONTRACTOR WHEN A OR OTHER PACKAGING SYSTEM, COMPLETE WITH LABELS AND INSTRUCTIONS FOR HANDLING, STORING, UNPACKING, FAX: 916 266-6006 ( ) 1.10 CONTRACTOR SHALL NOT MAKE, CAUSED TO BE MADE, OR PERMIT A SUBCONTRACTOR TO MAKE ANY CHANGE TO 2.11 ALL EXISTING LIFE -SAFETY SYSTEMS ALARMS, EMERGENCY LIGHTING, FIRE PROTECTION, ETC. ( ) SHALL REMAIN IN SUBMITTAL BEING PROCESSED MUST BE DELAYED FOR COORDINATION. PROTECTING, AND INSTALLING. CONTACT: HATE HENINGER natehenin er®carrilloa com 9 g' C-DOPERATION WHAT IS SPECIFIED ON THE PLAN WITHOUT SPECIFIC AUTHORIZATION OF THE NCM. TO THE MAXIMUM EXTENT POSSIBLE. ALL FIRE PROTECTION SYSTEMS SHALL BE OPERATIONAL DURING 2. RESUBMITTAL REVIEW: ALLOW [5] FIVE DAYS FOR REVIEW OF EACH RESUBMITTAL. 4. INSPECT PRODUCTS ON DELIVERY TO ENSURE COMPLIANCE WITH THE CONTRACT DOCUMENTS AND TO ENSURE THAT 1.11 THE ARCHITECT IS NOT RESPONSIBLE FOR ERRORS, OMISSIONS OR DELAYS BY THE CONTRACTOR. ALL NON -CONSTRUCTION TIMES. MAINTAIN ALL EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND LIFE SAFETY SYSTEMS IN WORKING ORDER. C. IDENTIFICATION: PLACE A PERMANENT LABEL OR TITLE BLOCK ON EACH SUBMITTAL FOR IDENTIFICATION. PRODUCTS ARE UNDAMAGED AND PROPERLY PROTECTED. C. STORAGE: MEP ENGINEERS 1.12 CONTRACTOR SHALL COORDINATE SCHEDULING, PROVISIONS FOR INSTALLATION, LOCATIONS AND THE ACTUAL 1. INDICATE NAME OF FIRM OR ENTITY THAT PREPARED EACH SUBMITTAL ON LABEL OR TITLE BLOCK. 2PROVIDE A SPACE ON LABEL OR BESIDE TITLE BLOCK TO RECORD CONTRACTOR'S REVIEW AND APPROVAL 1. STORE PRODUCTS TO ALLOW FOR INSPECTION AND MEASUREMENT OF QUANTITY OR COUNTING OF UNITS. HENDERSON ENGINEERS. INSTALLATION OF ITEMS FURNISHED BY TENANT OR BY OTHERS. MARKINGS AND ACTION TAKEN BY ARCHITECT. 2, STORE PRODUCTS THAT ARE SUBJECT TO DAMAGE BY THE ELEMENTS, UNDER COVER IN A WFATHERTIGHT ENCLOSURE 1.13 OTHER CONTRACTORS AND THEIR SUBCONTRACTORS MAY BE WORKING ON THE PREMISES SIMULTANEOUS WITH THE ART 3 - MILLWORK NOTES 3. INCLUDE THE FOLLOWING INFORMATION ON LABEL FOR PROCESSING AND RECORDING ACTION TAKEN: ABOVE GROUND, WITH VENTILATION ADEQUATE TO PREVENT CONDENSATION. 3. STORE CEMENTITIOUS PRODUCTS AND MATERIALS ON ELEVATED PLATFORMS. 8325 LENEXA DRIVE, SUITE 400 DURATION OF THE CONTRACT. NO ACTION SHALL BE TAKEN ON THE PART OF THIS CONTRACTOR ON THE PREMISES, 3.1 NOTE THAT THE METHOD OF MANUFACTURING, FABRICATING AND INSTALLING ALL MILLWORK AND EQUIPMENT AND ITS A. PROJECT NAME. 4. COMPLY WITH PRODUCT MANUFACTURER'S WRITTEN INSTRUCTIONS FOR TEMPERATURE, HUMIDITY, VENTILATION, AND LENEXA, KS 66214 UNION OR NON -UNION. 1.14 COOPERATE WITH ALL TRADES ON THE PROJECT NOT UNDER CONTRACT TO THE GENERAL CONTRACTOR (I.E. STRUCTURAL COMPONENTS DEFINED IN THE CONTRACT DOCUMENTS ITS REPRESENTATIVE AND INDICATES DESIGN INTENT ONLY. IF THE MATERIALS, DETAILS OR DIMENSIONAL PROPERTIES ARE AT VARIANCE WITH THE GC'S OR MANUFACTURER'S RECOMMENDATIONS, ALTERNATE DETAILS WILL BE CONSIDERED FOR REVIEW BY THE NCM WHEN B. DATE. C. NAME AND ADDRESS OF ARCHITECT. D. NAME AND ADDRESS OF CONTRACTOR. WEATHER -PROTECTION REQUIREMENTS FOR STORAGE. 5. PROTECT STORED PRODUCTS FROM DAMAGE AND LIQUIDS FROM FREEZING. PHONE: (913) 307-5464 FAX: (913) 307-5400 TELEPHONE, COMPUTER INSTALLERS, ETC.). ANY CHANGES OR DELAYS ARISING FROM CONFLICTS BETWEEN SUCH SHOP DRAWINGS ARE SUBMITTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. IT SHALL BE THE E. NAME AND ADDRESS OF SUBCONTRACTOR. 1.6 PRODUCT WARRANTIES CONTACT: TREVOR JONES trevor.Jones®hendersonengineers.com TRADES SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AT NO ADDITIONAL COST TO THE TENANT. RESPONSIILITY OF THE GC TO GUARANTEE THAT THE MILLWORK AND EQUIPMENT WILL HAVE PROPER SUPPORT, F. NAME AND ADDRESS OF SUPPLIER. A. WARRANTIES SPECIFIED IN OTHER SECTIONS SHALL BE IN ADDITION TO, AND RUN CONCURRENT WITH, OTHER WARRANTIES 1.15 DO NOT SCALE DRAWINGS, FOLLOW WRITTEN DIMENSIONS OR KEYED NOTES ONLY, CONTACT NCM IMMEDIATELY FOR STABILITY, AND FAULT -FREE PERFORMANCE. ALTERNATE RECOMMENDATIONS FOR MAJOR DESIGN CHANGES WILL G. NAME OF MANUFACTURER. REQUIRED BY THE CONTRACT DOCUMENTS, MANUFACTURER'S DISCLAIMERS AND LIMITATIONS ON PRODUCT WARRANTIES DO NOT RELIEVE CONTRACTOR OF OBLIGATIONS UNDER REQUIREMENTS OF THE CONTRACT DOCUMENTS. LANDLORD CLARIFICATION IF REQUIRED. VERIFY DIMENSIONS IN THE FIELD. LARGE SCALE DETAILS GOVERN OVER SMALL SCALE NOT BE CONSIDERED. H. SUBMITTAL NUMBER OR OTHER UNIQUE IDENTIFIER, INCLUDING REVISION IDENTIFIER. INVESTCORP / ORANGE DETAILS. 3.2 PROVIDE BLOCKING IN GYPSUM BOARD PARTITIONS FOR ANY WALL -MOUNTED ARCHITECTURAL WOODWORK, FINISH I. NUMBER AND TITLE OF APPROPRIATE SPECIFICATION SECTION. SECTION 01700 - EXECUTION REQUIREMENTS BRISTOL, LP 1.16 ALL WALL DIMENSIONS ARE AS FOLLOWS UNLESS NOTED OTHERWISE: CARPENTRY, FURNITURE, EQUIPMENT, ETC. ALL BLOCKING SHALL BE FIRE RETARDANT TREATED WOOD. J. AS APPROPRIATE DRAWING NUMBER AND DETAIL REFERENCES, . K. LOCATIONS) WHERE PRODUCT IS TO BE INSTALLED, AS APPROPRIATE. PART 1 -GENERAL 280 PARK AVE, 36TH FLOOR w A. FINISHED FACE OF PARTITION / WALL. 3.3 THE MILLWORK CONTRACTOR SHALL OBTAIN AND VERIFY ALL FIELD MEASUREMENTS AND SHALL BE RESPONSIBLE FOR L. OTHER NECESSARY IDENTIFICATION. 1.1 SUMMARY A. THIS SECTION INCLUDES GENERAL PROCEDURAL REQUIREMENTS GOVERNING EXECUTION OF THE WORK INCLUDING, BUT NOT NEW YORK, NY 10017 B. CENTER LINE OF WALL EQUALS CENTER LINE OF MULLION. ALL DETAILS AND DIMENSIONS ASSURING PRECISION AND PROPER ASSEMBLY OF HIS PRODUCTS. ANY VARIANCE D. DEVIATIONS: HIGHLIGHT, ENCIRCLE, OR OTHERWISE SPECIFICALLY IDENTIFY DEVIATIONS FROM THE CONTRACT DOCUMENTS LIMITED THE FOLLOWING: PHONE: (212) 577-1414 FOUND IN THE FIELD MUST BE BROUGHT TO THE ATTENTION OF THE NCM. ON SUBMITTALS. 1. CONSSTT RUCTION LAYOUT. C. TO TOP OF FINISH SLAB AT FLOORS. 3.4 REINFORCING AS REQUIRED TO ENSURE A RIGID AND SECURE ASSEMBLY SHALL BE PROVIDED WHERE NECESSARY, E. DISTRIBUTION: FURNISH COPIES OF FINAL SUBMITTALS TO MANUFACTURERS, SUBCONTRACTORS, SUPPLIERS, FABRICATORS, 2. GENERAL INSTALLATION OF PRODUCTS. CONTACT: HEATHER MUTTERPERL D. TO BOTTOM OF FINISH AT CEILINGS. EVEN IF NOT DETAILED ON ARCHITECT'S DRAWINGS. EXPOSED SURFACES SHALL BE FREE FROM DENTS, TOOL INSTALLERS, AUTHORITIES HAVING JURISDICTION, AND OTHERS AS NECESSARY FOR PERFORMANCE OF CONSTRUCTION 3. PROGRESS CLEANING. 1.17 "MINIMUM" OR "MIN." AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION IS SLIGHTLY ADJUSTABLE MARKS, WARPAGE, BUCKLE, GLUE AND OPEN JOINTS. ALL JOINTS, CORNERS AND MITER CONNECTIONS SHALL BE ACTIVITIES, SHOW DISTRIBUTION ON TRANSMITTAL FORMS. PART 2 - EXECUTION 4. PROTECTION OF INSTALLED CONSTRUCTION. BUT MAY NOT VARY TO A DIMENSION OR QUANTITY LESS THEN THAT SHOWN WITHOUT THE APPROVAL OF ARCHITECT. MADE UP TIGHTLY SO THAT THREADS ARE ENTIRELY CONCEALED. 2.1 CONTRACTOR'S REVIEW 5. CORRECTION OF THE WORK. "MAXIMUM" OR "MAX" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION IS SLIGHTLY ADJUSTABLE 3.5 SET WORK PLUMB, LEVEL AND SQUARE, SCRIBED TIGHTLY AND ACCURATELY TO ADJACENT SURFACES AND SECURELY A. REVIEW EACH SUBMITTAL AND CHECK FOR COORDINATION WITH OTHER WORK OF THE CONTRACT AND FOR COMPLIANCE PART 2 - EXECUTION 2.1 EXAMINATION BUT MAY NOT VARY TO A DIMENSION OR QUANTITY GREATER THAN THAT SHOWN WITHOUT THE APPROVAL OF ANCHOR IN POSITION INDICATED ON DRAWINGS. SHIM AS REQUIRED, USING CONCEALED SHIMS. WITH THE CONTRACT DOCUMENTS. NOTE CORRECTIONS AND FIELD DIMENSIONS. MARK WITH APPROVAL STAMP BEFORE A. EXISTING CONDITIONS: THE EXISTENCE AND LOCATION OF SITE IMPROVEMENTS, UTILITIES, AND OTHER CONSTRUCTION ARCHITECT. 3.6 REPAIR, REPLACE OR OTHERWISE MAKE GOOD TO SATISFACTION OF NCM ALL DAMAGE INCURRED TO MILLWORK SUBMITTING TO ARCHITECT. INDICATED AS EXISTING ARE NOT GUARANTEED. BEFORE BEGINNING WORK, INVESTIGATE AND VERIFY THE EXISTENCE AND 1.18 "TYPICAL" OR "TYP ° AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION OR DIMENSION IS THE SAME DURING CONSTRUCTION. 2.2 ARCHITECT'S ACTION LOCATION OF MECHANICAL AND ELECTRICAL SYSTEMS AND OTHER CONSTRUCTION AFFECTING THE WORK. OR REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT. 3.7 ADJUST DOORS, DRAWERS AND ALL HARDWARE FOR PROPER OPERATION AND CLEAN ALL SURFACES, INSIDE AND OUT. A. GENERAL: ARCHITECT WILL NOT REVIEW SUBMITTALS THAT DO NOT BEAR CONTRACTOR'S APPROVAL STAMP AND WILL RETURN THEM WITHOUT ACTION. 1. BEFORE CONSTRUCTION, VERIFY THE LOCATION AND POINTS OF CONNECTION OF UTILITY SERVICES. 1.19 "MATCH EXIST." AS USED IN THE DOCUMENTS SHALL MEAN THAT THE CONDITION OR MATERIAL IS TO SEAMLESSLY 3.8 COMPLY WITH MILLWORK MANUFACTURERS AND INSTALLERS RECOMMENDED OPTIMUM TEMPERATURE AND HUMIDITY 1. ACTION SUBMITTALS: ARCHITECT WILL REVIEW EACH SUBMITTAL, MAKE MARKS TO INDICATE CORRECTIONS OR B. EXISTING UTILITIES: THE EXISTENCE AND LOCATION OF UNDERGROUND AND OTHER UTILITIES AND CONSTRUCTION INDICATED AS EXISTING NOT GUARANI BEFORE I T S G ARE EEO BE RE BEGINNING (GATE AND VERIFY THE EXISTENCE AND LOCATION MATCH THE SURROUNDING OR PRESCRIBE MATERIAL IN STYLE, PROFILE, COLOR, TEXTURE AND, WHERE POSSIBLE, CONDITIONS FOR STORAGE AND INSTALLATION OF MILLWORK. MODIFICATIONS REQUIRED, AND RETURN IT. ARCHITECT WILL STAMP EACH SUBMITTAL WITH AN ACTION STAMP AND OF UNDERGROUND UTILITIES AND OTHER CONSTRUCTION AFFECTING THE WORK. AFFECTING E W w MANUFACTURE. "ALIGN" 3.9 ALIGN ALL UPPER AND LOWER CABINETRY, TYPICAL UNLESS NOTED OTHERWISE. WILL MARK STAMP APPROPRIATELY TO INDICATE ACTION TAKEN. t. BEFORE CONSTRUCTION, VERIFY THE LOCATION AND INVERT ELEVATION AT POINTS OF CONNECTION OF SANITARY SEWER, 1.20 AS USED IN THESE DOCUMENTS SHALL MEAN TO ACCURATELY LOCATE AND FINISH FACES IN THE SAME STORM SEWER, AND WATER -SERVICE PIPING; AND UNDERGROUND ELECTRICAL SERVICES. PLANE; AND/OR TO INSTALL NEW CONSTRUCTION ADJACENT TO EXISTING CONSTRUCTION WITHOUT ANY VISIBLE JOINTS 3.10 ALIGN CABINET PULLS VERTICALLY, TYPICAL UNLESS NOTED OTHERWISE. 2. FURNISH LOCATION DATA FOR WORK RELATED TO PROJECT THAT MUST BE PERFORMED BY PUBLIC UTILITIES SERVING OR SURFACE IRREGULARITIES. 3.11 ALL CABINETRY HARDWARE (EXCEPT PULLS) TO BE FULLY CONCEALED, HEAVY-DUTY COMMERCIAL GRADE, UNO. SECTION 01500 - TEMPORARY FACILITIES AND CONTROLS PROJECT SITE. i.21 ANY DISCREPANCIES T LOCATION BETWEEN THE ARCHITECTURAL AND ENGINEERING DRAWINGS BETWEEN THE PART 1 - GENERAL 1.1 SUMMARY C. ACCEPTANCE OF CONDITIONS: EXAMINE SUBSTRATES, AREAS, AND CONDITIONS, WITH INSTALLER OR APPLICATOR PRESENT DRAWINGS AND EXISTING FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE NCM FOR NO PART 4 -REFLECTED CEILING PLAN NOTES A. RE U THIS SECTION INCLUDES REQIEENTS FOR TEMPORARY UTILITIES, SUPPORT FACILITIES, AND SECURITY AND PROTECTION QUIREMENTS WHERE INDICATED, FOR COMPLIANCE WITH REQUIREMENTS FOR INSTALLATION TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE. RECORD OBSERVATIONS. CLARIFICATIONS. WORK INSTALLED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED BY THE FACILITIES. CONTRACTOR AT THE CONTRACTOR'S EXPENSE AND SHALL NOT IMPACT THE SCHEDULE. 4.1 ALL MATERIALS IN AIR DISTRIBUTION PLENUMS SHALL HAVE A MAXIMUM FLAME -SPREAD RATING OF 25. 1.2 USE CHARGES 1. VERIFY COMPATIBILITY WITH AND SUITABILITY OF SUBSTRATES, INCLUDING COMPATIBILITY WITH EXISTING FINISHES OR 1.22 "CLEAR" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE DIMENSION IS NOT ADJUSTABLE WITHOUT THE 4.2 CEILING GRIDS SHALL BE CENTERED IN ROOM OR SPACE WITH EQUAL BORDERS, UNLESS NOTED OTHERWISE. A. GENERAL: COST OR USE CHARGES FOR TEMPORARY FACILITIES SHALL BE INCLUDED IN THE CONTRACT SUM. ALLOW OTHER PRIMERS. 2. EXAMINE ROUGHING -IN FOR MECHANICAL AND ELECTRICAL SYSTEMS TO VERIFY ACTUAL LOCATIONS OF CONNECTIONS APPROVAL OF THE ARCHITECT. CLEAR DIMENSIONS SHALL BE ACCURATE TO FINISH WALL MATERIAL. CONTACT 4.3 ACCESS PANELS, REQUIRED, SHALL BE INSTALLED FLUSH IN CEILING AND FINISHED TO MATCH THE ADJACENT ENTITIES TO USE TEMPORARY SERVICES AND FACILITIES WITHOUT COST, INCLUDING, BUT NOT LIMITED TO,[ OWNER'S BEFORE EQUIPMENT AND FIXTURE INSTALLATION. ARCHITECT PRIOR TO CONSTRUCTION IF FIELD CONDITIONS DO NOT ACCOMMODATE SAID DIMENSION. CEILING FINISH. LOCATIOONS O LOCATIONS O F ALL ACCESS PANELS ARE TO BE REVIEWED WITH THE NCM, CONSTRUCTION FORCES ,] ARCHITECT,[ OCCUPANTS OF PROJECT ,] TESTING AGENCIES, AND AUTHORITIES HAVING 3. EXAMINE WALLS, FLOORS, AND ROOFS FOR SUITABLE CONDITIONS WHERE PRODUCTS AND SYSTEMS ARE TO BE 1.23 THE GENERAL CONTRACTOR SHALL VERIFY SIZE, LOCATION AND CHARACTERISTICS OF ALL WORK AND EQUIPMENT SUPPLIED BY THE TENANT OR OTHERS, WITH THE MANUFACTURER OR SUPPLIER PRIOR TO THE START OF RELATED 4.4 COORDINATE ALL ELECTRICAL PENETRATIONS, CONDUITS, AND BOXES WITH CODE REQUIREMENTS & ELECTRICAL JURISDICTION. B. WATER SERVICE: WATER FROM OWNER'S EXISTING WATER SYSTEM IS AVAILABLE FOR USE WITHOUT METERING AND WITHOUT INSTALLED. 4. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. PROCEEDING WITH WORK. DOCUMENTS. PAYMENT OF USE CHARGES. PROVIDE CONNECTIONS AND EXTENSIONS OF SERVICES AS REQUIRED FOR CONSTRUCTION THE WORK INDICATES ACCEPTANCE OF SURFACES AND CONDITIONS. OPERATIONS. 2.2 PREPARATION 1.24 INSTALL AND MAINTAIN ALL NECESSARY COVERINGS. PROTECTIVE ENCLOSURES, TEMPORARY DOORS AND PARTITIONS C. ELECTRIC POWER SERVICE: ELECTRIC POWER FROM OWNER'S EXISTING SYSTEM IS AVAILABLE FOR USE WITHOUT METERING A. FIELD MEASUREMENTS: TAKE FIELD MEASUREMENTS AS REQUIRED TO FIT THE WORK PROPERLY. RECHECK MEASUREMENTS o AND DUST BARRIERS TO PROTECT ALL OCCUPANTS AND REPLACE ANY DAMAGES CAUSED BY IMPROPER PROTECTION PART 5 -FINISH PLAN NOTES AND WITHOUT PAYMENT OF USE CHARGES. PROVIDE CONNECTIONS AND EXTENSIONS OF SERVICES AS REQUIRED FOR BEFORE INSTALLING EACH PRODUCT. WHERE PORTIONS OF THE WORK ARE INDICATED TO FIT TO OTHER CONSTRUCTION, AT NO ADDITIONAL CHARGE TO TENANT. 5.1. BEFORE PROCEEDING WITH PROCUREMENT, THE RESPECTIVE INSTALLER SHALL FIELD VERIFY DIMENSIONS TO ASSURE CONSTRUCTION OPERATIONS. VERIFY DIMENSIONS OF OTHER CONSTRUCTION BY FIELD MEASUREMENTS BEFORE FABRICATION. COORDINATE FABRICATION 1.25 WARRANT TO THE TENANT THAT ALL MATERIALS AND EQUIPMENT FURNISHED AND INSTALLED UNDER THIS CONTRACT THAT SUFFICIENT QUANTITIES OF MATERIALS ARE ORDERED TO COMPLETE THE WORK. 1.3 QUALITY ASSURANCE SCHEDULE WITH CONSTRUCTION PROGRESS TO AVOID DELAYING THE WORK. SHALL BE NEW, UNLESS OTHERWISE FREE FROM FAULTS AND DEFECTS AND CONFORMS WITH THE CONTRACT 5.2 UPON RECEIPT FROM THE MANUFACTURER, THE INSTALLER SHALL INSPECT MATERIALS FOR DEFECTS, FLAWS, A. ELECTRIC SERVICE: COMPLY WITH NECA, NEMA, AND UL STANDARDS AND REGULATIONS FOR TEMPORARY ELECTRIC SERVICE. INSTALL SERVICE TO COMPLY WITH NFPA 70. B. SPACE REQUIREMENTS: VERIFY SPACE REQUIREMENTS AND DIMENSIONS OF ITEMS SHOWN DIAGRAMMATIC ALLY ON DRAWINGS. DOCUMENTS. SHIPPING DAMAGE, CORRECT COLOR AND PATTERN. PRIOR TO BEGINNING WORK, DAMAGED OR WRONG MATERIALS B. TESTS AND INSPECTIONS: ARRANGE FOR AUTHORITIES HAVING JURISDICTION TO TEST AND INSPECT EACH TEMPORARY UTILITY C. REVIEW OF CONTRACT DOCUMENTS AND FIELD CONDITIONS: IMMEDIATELY ON DISCOVERY OF THE NEED FOR CLARIFICATION OF THE CONTRACT DOCUMENTS, SUBMIT A REQUEST FOR INFORMATION TO ARCHITECT. INCLUDE A DETAILED DESCRIPTION 1.26 CONTRACTOR SHALL FULLY ACQUAINT HIMSELF WITH THE CONDITIONS OF THE CONTRACT. LOCAL CONDITIONS SHALL BE RETURNED TO THE MANUFACTURER FOR IMMEDIATE REPLACEMENT TO PREVENT DELAYS IN COMPLETION OF BEFORE USE. OBTAIN REQUIRED CERTIFICATIONS AND PERMITS. OF PROBLEM ENCOUNTERED, TOGETHER WITH RECOMMENDATIONS FOR CHANGING THE CONTRACT DOCUMENTS. RELATING TO LOCATION, ACCESSIBILITY AND GENERAL CHARACTER OF THE CONSTRUCTION SITE AND LOCAL LABOR THE WORK. COMPLIANCE WITH THE MANUFACTURER'S REQUIREMENTS FOR HANDLING, STORAGE, INSTALLATION AND 1.4 PROJECT CONDITIONS 2.3 CONSTRUCTION LAYOUT CONDITIONS SO THAT HE UNDERSTANDS THE NATURE, EXTENT, DIFFICULTIES AND RESTRICTIONS RELATED TO THE EXECUTION OF THE WORK. PROTECTION IS THE EXCLUSIVE RESPONSIBILITY OF THE GC AND HIS/HER RESPECTIVE INSTALLERS. 5.3 THE RESPECTIVE INSTALLER SHALL ADVISE THE NCM OF LOCATIONS OR CHANGES IN DYE LOTS, BATCHES, OR SIMILAR A. TEMPORARY USE OF PERMANENT FACILITIES: INSTALLER OF EACH PERMANENT SERVICE SHALL ASSUME RESPONSIBILITY FOR OPERATION, MAINTENANCE, AND PROTECTION OF EACH PERMANENT SERVICE DURING ITS USE AS A CONSTRUCTION FACILITY A. VERIFICATION: BEFORE PROCEEDING TO LAY OUT THE WORK, VERIFY LAYOUT INFORMATION SHOWN ON DRAWINGS. IF DISCREPANCIES ARE DISCOVERED, NOTIFY ARCHITECT PROMPTLY. 1.27 INVESTIGATE JOB SITE TO COMPARE CONTRACT DOCUMENTS AND EXISTING CONDITIONS. INCLUDE COST FOR ALL COLOR SHIFTS. BEFORE OWNER'S ACCEPTANCE, REGARDLESS OF PREVIOUSLY ASSIGNED RESPONSIBILITIES. 2.4 PROGRESS CLEANING WORK DESCRIBED IN CONTRACT DOCUMENTS AND REQUIRED OR IMPLIED BY EXISTING CONDITIONS. NOTIFY NCM OF PART 2 - PRODUCTS A. GENERAL: CLEAN PROJECT SITE AND WORK AREAS DAILY, INCLUDING COMMON AREAS. COORDINATE PROGRESS CLEANING NY XISTING CONDITIONS AND NEW WORK, OMISSIONS OR CONFLICTS IN THE DRAWINGS AND ACONFUCTS BETWEEN E 5.4 THE GC SHALL PROVIDE ONE FINAL TOUCH-UP OF PAINT SURFACES AFTER THE TENANT HAS MOVED INTO THE 2.1 EQUIPMENT FOR JOINT -USE AREAS WHERE MORE THAN ONE INSTALLER HAS WORKED. ENFORCE REQUIREMENTS STRICTLY. DISPOSE OF ANY RESTRICTIONS RELATED TO THE EXECUTION OF THE WORK. SPACE. A. FIRE EXTINGUISHERS: PORTABLE, UL RATED; WITH CLASS AND EXTINGUISHING AGENT AS REQUIRED BY LOCATIONS AND MATERIALS LAWFULLY. 1.28 PROCURE MATERIALS SO AS NOT TO DELAY SUBSTANTIAL COMPLETION. NOTIFY NCM WITHIN 5 DAYS OF EXECUTION 5.5 EXISTING CEILING REGISTERS, VENTS, GRILLES, DIFFUSERS, ETC. SHALL BE PAINTED IN SEMI -GLOSS TO MATCH CLASSES OF FIRE EXPOSURES. B. HEATING EQUIPMENT: UNLESS OWNER AUTHORIZES USE OF PERMANENT HEATING SYSTEM, PROVIDE VENTED, B. WORK AREAS: CLEAN AREAS WHERE WORK IS IN PROGRESS TO THE LEVEL OF CLEANLINESS NECESSARY FOR PROPER EXECUTION OF THE WORK. OF CONTRACT OF ANY MATERIAL DELIVERY WHICH WOULD DELAY COMPLETION OF CONTRACT. CEILING. SELF-CONTAINED, LIQUID -PROPANE -GAS OR FUEL -OIL HEATERS WITH INDIVIDUAL SPACE THERMOSTATIC CONTROL. C. CONCEALED SPACES: REMOVE DEBRIS FROM CONCEALED SPACES BEFORE ENCLOSING THE SPACE. v 1.29 CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR VERIFYING AND LOCATING ALL UNDERGROUND OR UNDERSLAB 5.6 FINISHES CALLED OUT SHALL EXTEND OVER, UNDER, AND/OR BEHIND ANY ITEM OF BUILT-IN MILLWORK EQUIPMENT, 1. USE OF GASOLINE -BURNING SPACE HEATERS, OPEN -FLAME HEATERS, OR SALAMANDER -TYPE HEATING UNITS IS D, EXPOSED SURFACES IN FINISHED AREAS: CLEAN EXPOSED SURFACES AND PROTECT AS NECESSARY TO ENSURE FREEDOM UTILITIES, ETC. PRIOR TO START OF CONSTRUCTION. MIRRORS, ETC. AS INDICATED ON DRAWINGS. PROHIBITED. FROM DAMAGE AND DETERIORATION AT TIME OF SUBSTANTIAL COMPLETION. 1.30 REVIEW PLANS AND PROVIDE BRACING/BLOCKING IN GYPSUM BOARD PARTITIONS AS REQUIRED FOR ANY 5.7 COVE BASE TO BE USED IN ALL AREAS AS INDICATED. THE GC SHALL USE INSIDE AND OUTSIDE CORNERS AND END 2. HEATING UNITS: LISTED AND LABELED FOR TYPE OF FUEL BEING CONSUMED, BY A TESTING AGENCY ACCEPTABLE TO E, DURING HANDLING AND INSTALLATION, CLEAN AND PROTECT CONSTRUCTION IN PROGRESS AND ADJOINING MATERIALS t PLAN CHECK COMMENTS 1 /20/05 WALL -MOUNTED WOODWORK, CASEWORK, FINISH CARPENTRY, FURNITURE, EQUIPMENT, ETC. FOR WOOD BLOCKING STOPS FOR AREAS SPECIFIED. USE ROLL GOODS ONLY. NO SEAMS SHALL OCCUR WITHIN 6" OF AN OUTSIDE AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. PART 3 - EXECUTION ALREADY IN PLACE. APPLY PROTECTIVE COVERING WHERE REQUIRED TO ENSURE PROTECTION FROM DAMAGE OR PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING. CORNER. 3.1 INSTALLATION, GENERAL DETERIORATION AT SUBSTANTIAL COMPLETION. F. CLEAN AND PROVIDE MAINTENANCE ON COMPLETED CONSTRUCTION AS FREQUENTLY AS NECESSARY THROUGH THE T ISSUED FOR PERMIT AND BID 1 /7/04 1.31 EXAMINE ALL SURFACES TO DETERMINE THAT THEY ARE SOUND, DRY, CLEAN AND READY TO RECEIVE FINISHES OR 5.8 TYPICAL - WALLS TO BE PAINTED P-1, IN EGGSHELL FINISH UNLESS OTHERWISE NOTED, A. LOCATE FACILITIES WHERE THEY WILL SERVE PROJECT ADEQUATELY AND RESULT IN MINIMUM INTERFERENCE WITH REMAINDER OF THE CONSTRUCTION PERIOD. ADJUST AND LUBRICATE OPERABLE COMPONENTS TO ENSURE OPERABILITY No. Revisions Submissions / Date MILLWORK PRIOR TO INSTALLATIONS. START OF INSTALLATION SHALL IMPLY ACCEPTANCE OF SUBSTRATE AND SHALL PERFORMANCE OF THE WORK. RELOCATE AND MODIFY FACILITIES AS REQUIRED BY PROGRESS OF THE WORK. WITHOUT DAMAGING EFFECTS. NOT BE GROUNDS FOR CLAIMS IMPROPER PERFORMANCE OF INSTALLED MATERIALS. ADVISE NCM OF ANY EXISTING 5.9 CONTRACTOR TO FURNISH AND INSTALL REDUCING STRIP AT ALL VCT FLOORING AND OTHER FLOORING TRANSITIONS. B. PROVIDE EACH FACILITY READY FOR USE WHEN NEEDED TO AVOID DELAY. DO NOT REMOVE UNTIL FACILITIES ARE NO G. LIMITING EXPOSURES: SUPERVISE CONSTRUCTION OPERATIONS TO ASSURE THAT NO PART OF THE CONSTRUCTION, CARRILLOINSTRUCTIONS CONSTRUCTION NOT LEVEL, SMOOTH AND PLUMB WITHIN INDUSTRY STANDARDS PRIOR TO START OF CONSTRUCTION WHICH WILL BE DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THAT INSTALLERS WORK. 5.10 CONTRACTOR TO PROVIDE 10% OF ALL MATERIALS INCLUDING BUT NOT LIMITED TO FLOOR FINISHES, CEILING FINISHES, WALL BASES, ETC. FOR "ATTIC STOCK". LONGER NEEDED OR ARE REPLACED BY AUTHORIZED USE OF COMPLETED PERMANENT FACILITIES. 3.2 SECURITY AND PROTECTION FACILITIES INSTALLATION COMPLETED OR IN PROGRESS, IS SUBJECT TO HARMFUL, DANGEROUS, DAMAGING, OR OTHERWISE DELETERIOUS EXPOSURE DURING THE CONSTRUCTION PERIOD. 1.32 PERFORM ALL WORK AND INSTALL MATERIALS IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND A. ENVIRONMENTAL PROTECTION: PROVIDE PROTECTION, OPERATE TEMPORARY FACILITIES, AND CONDUCT CONSTRUCTION IN WAYS 2.5 PROTECTION OF INSTALLED CONSTRUCTION AND IN A MANNER CONSISTENT WITH INDUSTRY STANDARDS OF WORKMANSHIP. AND BY METHODS THAT COMPLY WITH ENVIRONMENTAL REGULATIONS AND THAT MINIMIZE POSSIBLE AIR, WATERWAY, AND A. PROVIDE FINAL PROTECTION AND MAINTAIN CONDITIONS THAT ENSURE INSTALLED WORK IS WITHOUT DAMAGE OR SUBSOIL CONTAMINATION OR POLLUTION OR OTHER UNDESIRABLE EFFECTS. DETERIORATION AT TIME OF SUBSTANTIAL COMPLETION. A R C H I T E C T U R A L G R O U P I N C 1.33 NO UNFINISHED GYP. WORK AND WOOD WORK ALLOWED, INCLUDING BEHIND FURNITURE & ANY EQUIPMENT ITEMS. B. SECURITY ENCLOSURE AND LOCKUP: INSTALL SUBSTANTIAL TEMPORARY ENCLOSURE AROUND PARTIALLY COMPLETED AREAS B. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR TEMPERATURE AND RELATIVE HUMIDITY. J, Steven Carrillo 11231 Gold Express Dr. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED, SPACKLED, AND SANDED SMOOTH WITH NO VISIBLE JOINTS, PAINT OF CONSTRUCTION. PROVIDE LOCKABLE ENTRANCES TO PREVENT UNAUTHORIZED ENTRANCE, VANDALISM, THEFT, AND SIMILAR 2.6 CORRECTION OF THE WORK A.I.A. C11.222 Suite 103 I Gold River, 95670 AS SPECIFIED. PROVIDE GALVANIZED METAL CORNER BEADS AND SIMILAR CONCEALED TRIM AT ALL EXPOSED EDGES; VIOLATIONS OF SECURITY. A. REPAIR OR REMOVE AND REPLACE DEFECTIVE CONSTRUCTION. RESTORE DAMAGED SUBSTRATES AND FINISHES. COMPLY s1s 2ss-s000 0 USE EXPOSED TRIM ONLY AS APPROVED BY NCM. C. BARRICADES, WARNING SIGNS, AND LIGHTS: COMPLY WITH REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION FOR WITH REQUIREMENTS IN DIVISION 1 SECTION "CUTTING AND PATCHING." FAX 266-6006 CO 1.34 RECESSED ITEMS SHALL BE INSTALLED FLUSH WITH THE PARTITION UNLESS NOTED OTHERWISE. PARTITION DEPTH ERECTING STRUCTURALLY ADEQUATE BARRICADES, INCLUDING WARNING SIGNS AND LIGHTING. 1. REPAIRING INCLUDES REPLACING DEFECTIVE PARTS, REFINISHING DAMAGED SURFACES, TOUCHING UP WITH MATCHING THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN SHALL BE ADJUSTED TO ACCOMMODTE DEPTH OF THE RECESSED ITEM. COORDINATE WITH THE NCM. D. TEMPORARY ENCLOSURES: PROVIDE TEMPORARY ENCLOSURES FOR PROTECTION OF CONSTRUCTION, IN PROGRESS AND MATERIALS, AND PROPERLY ADJUSTING OPERATING EQUIPMENT. THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, COMPLETED, FROM EXPOSURE, FOUL WEATHER, OTHER CONSTRUCTION OPERATIONS, AND SIMILAR ACTIVITIES. PROVIDE B. RESTORE PERMANENT FACILITIES USED DURING CONSTRUCTION TO THEIR SPECIFIED CONDITION. CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY 1.35 WORK DAMAGED DURING CONSTRUCTION OR NOT CONFORMING TO SPECIFIED STANDARDS, TOLERANCE OR MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION SHALL BE REPLACED AT NO ADDITIONAL COST TO THE TENANT. TEMPORARY WEATHERTIGHT ENCLOSURE FOR BUILDING EXTERIOR. C. REMOVE AND REPLACE DAMAGED SURFACES THAT ARE EXPOSED TO VIEW IF SURFACES CANNOT BE REPAIRED WITHOUT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE DRAWING IS NOT E. TEMPORARY FIRE PROTECTION: INSTALL AND MAINTAIN TEMPORARY FIRE -PROTECTION FACILITIES OF TYPES NEEDED TO VISIBLE EVIDENCE OF REPAIR. FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT. 1.36 OBTAIN THE NCM'S WRITTEN AUTHORIZATION BEFORE ANY WORK IS PERFORMED OR MATERIAL ORDERED WHICH PROTECT AGAINST REASONABLY PREDICTABLE AND CONTROLLABLE FIRE LOSSES. COMPLY WITH NFPA 241. D. REPAIR COMPONENTS THAT DO NOT OPERATE PROPERLY. REMOVE AND REPLACE OPERATING COMPONENTS THAT CANNOT DrawingTitle INVOLVES EXTRA COST OVER AND ABOVE CONTRACT PRICE. 1. PROHIBIT SMOKING IN CONSTRUCTION AREAS. BE REPAIRED. 3.3 OPERATION, TERMINATION, AND REMOVAL A. SUPERVISION: ENFORCE STRICT DISCIPLINE IN USE OF TEMPORARY FACILITIES. TO MINIMIZE WASTE AND ABUSE, LIMIT E, REMOVE AND REPLACE CHIPPED, SCRATCHED, AND BROKEN GLASS OR REFLECTIVE SURFACES. G E E ORAL NOTES AVAILABILITY OF TEMPORARY FACILITIES TO ESSENTIAL AND INTENDED USES. B. MAINTENANCE: MAINTAIN FACILITIES IN GOOD OPERATING CONDITION UNTIL REMOVAL. I { AI V D SPEC EI CATI 0 N S 1. MAINTAIN OPERATION OF TEMPORARY ENCLOSURES, HEATING, COOLING, HUMIDITY CONTROL, VENTILATION, AND SIMILAR Seal Drawn Checked FACILITIES ON A 24-HOUR BASIS WHERE REQUIRED TO ACHIEVE INDICATED RESULTS AND TO AVOID POSSIBILITY OF DAMAGE. A �` � � Rcjy TCB NSH Q C. TEMPORARY FACILITY CHANGEOVER: DO NOT CHANGE OVER FROM USING TEMPORARY SECURITY AND PROTECTION FACILITIES TO PERMANENT FACILITIES UNTIL SUBSTANTIAL COMPLETION. D. TERMINATION AND REMOVAL: REMOVE EACH TEMPORARY FACILITY WHEN NEED FOR ITS SERVICE HAS ENDED, WHEN IT HAS BEEN REPLACED BY AUTHORIZED USE OF A PERMANENT FACILITY, OR NO LATER THAN SUBSTANTIAL COMPLETION. COMPLETE OR, IF NECESSARY, RESTORE PERMANENT CONSTRUCTION THAT MAY HAVE BEEN DELAYED BECAUSE OF INTERFERENCE WITH _ „ - • • I _ A-1 " ' ( � � 4�1 CAS, . "I �� I ,{ (� 1 0 `_4 Project No. 04139.66 Date TEMPORARY FACILITY. REPAIR DAMAGED WORK, CLEAN EXPOSED SURFACES, AND REPLACE CONSTRUCTION THAT CANNOT BE I., I Ll I II , ) 1-7-05 SATISFACTORILY REPAIRED. � V ` -_�F 6. C 1 1 2 Q Scale 1. MATERIALS AND FACILITIES THAT CONSTITUTE TEMPORARY FACILITIES ARE PROPERTY OF CONTRACTOR. OWNER RESERVES RIGHT TO TAKE POSSESSION OF PROJECT IDENTIFICATION SIGNS. I REN � 5 4 FULL 2. AT SUBSTANTIAL COMPLETION, CLEAN AND RENOVATE PERMANENT FACILITIES USED DURING CONSTRUCTION PERIOD. �FA��� Drawing No. "CLOSEOUT _ Fn�.m �_.,�.,_ �� ��`°�"� � COMPLY WITH FINAL CLEANING REQUIREMENTS SPECIFIED IN DIVISION 1 SECTION PROCEDURES." •�� +L) ��*��''"`'#""'�°"' � G_ 1 I I I I I __ I 1 2 3 4 5 6 7 8 9 10 11 12 .., J P 1 2 3 4 5 6 7 8 9 10 11 12 SECTION 01731 - CUTTING AND PATCHING PART 1 - GENERAL 2.10 FINISHING FORMED SURFACES 3.2 INSTALLATION B. STANDARD STEEL DOORS: • 1.1 SUMMARY A. SMOOTH -FORMED FINISH: AS -CAST CONCRETE TEXTURE IMPARTED BY FORM -FACING MATERIAL, ARRANGED IN AN ORDERLY 1. EXTERIOR DOORS: PROVIDE WEEP -HOLE OPENINGS IN BOTTOM OF EXTERIOR DOORS TO PERMIT MOISTURE TO ESCAPE. A& A. THIS SECTION INCLUDES PROCEDURAL REQUIREMENTS FOR CUTTING AND PATCHING, AND SYMMETRICAL MANNER WITH A MINIMUM OF SEAMS. REPAIR AND PATCH TIE HOLES AND DEFECTS. REMOVE FINS AND A. INSTALL WORK IN ACCORDANCE WITH AWI CUSTOM QUALITY STANDARDS. SEAL JOINTS IN TOP EDGES OF DOORS AGAINST WATER PENETRATION. 1.2 QUALITY ASSURANCE OTHER PROJECTIONS THAT EXCEED SPECIFIED LIMITS ON FORMED -SURFACE IRREGULARITIES. B. SET AND SECURE MATERIALS AND COMPONENTS IN PLACE, PLUMB AND LEVEL. C. STANDARD STEEL FRAMES: WHERE FRAMES ARE FABRICATED IN SECTIONS DUE TO SHIPPING OR HANDLING LIMITATIONS, A. STRUCTURAL ELEMENTS: DO NOT CUT AND PATCH STRUCTURAL ELEMENTS IN A MANNER THAT COULD CHANGE THEIR 2.11 FINISHING FLOORS AND SLABS C. SCRIBE WORK ABUTTING OTHER COMPONENTS, WITH MAXIMUM GAPS OF 1/32 INCH. REFINISH CUT SURFACES OR PROVIDE ALIGNMENT PLATES OR ANGLES AT EACH JOINT, FABRICATED OF SAME THICKNESS METAL AS FRAMES. LOAD -CARRYING CAPACITY OR LOAD -DEFLECTION RATIO. A. GENERAL: COMPLY WITH ACI 302.1R RECOMMENDATIONS FOR SCREEDING, RESTRAIGHTENING, AND FINISHING OPERATIONS FOR REPAIR DAMAGED FINISH AND CUTS. 1. WELDED FRAMES: WELD FLUSH FACE JOINTS CONTINUOUSLY; GRIND, FILL, DRESS, AND MAKE SMOOTH, FLUSH, AND 1, OPERATIONAL ELEMENTS: DO NOT CUT AND PATCH OPERATING ELEMENTS AND RELATED COMPONENTS IN A MANNER CONCRETE SURFACES. DO NOT WET CONCRETE SURFACES. B. TROWEL FINISH: AFTER APPLYING FLOAT FINISH, APPLY FIRST TROWELING AND CONSOLIDATE CONCRETE BY HAND OR D. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. INVISIBLE. 2. DOOR SILENCERS: EXCEPT ON WEATHER-STRIPPED DOORS, DRILL STOPS TO RECEIVE DOOR SILENCERS AS FOLLOWS. A' 1446 S A T A A N A CA THAT RESULTS IN REDUCING THEIR CAPACITY TO PERFORM AS INTENDED OR THAT RESULTS IN INCREASED MAINTENANCE E. USE FIXTURE ATTACHMENTS IN CONCEALED LOCATIONS FOR WALL MOUNTED COMPONENTS. 1 tl OR DECREASED OPERATIONAL LIFE OR SAFETY B. VISUAL REQUIREMENTS: DO POWER -DRIVEN TROWEL. CONTINUE TROWELING PASSES AND RESTRAIGHTEN UNTIL SURFACE IS FREE OF TROWEL MARKS AND UNIFORM IN TEXTURE AND APPEARANCE. GRIND SMOOTH ANY SURFACE DEFECTS THAT WOULD TELEGRAPH THROUGH F. USE CONCEALED JOINT FASTENERS TO ALIGN AND SECURE ADJOINING CABINET UNITS AND COUNTER TOPS. PROVIDE PLASTIC PLUGS TO KEEP HOLES CLEAR DURING CONSTRUCTION. D. HARDWARE PREPARATION: FACTORY PREPARE STANDARD STEEL DOORS AND FRAMES TO RECEIVE TEMPLATED MORTISED � /� T SOUTH COAST S PLAZA NOT CUT AND PATCH CONSTRUCTION IN A MANNER THAT RESULTS IN VISUAL EVIDENCE OF G. SECURE CABINET AND COUNTER BASES TO FLOOR USING APPROPRIATE ANGLES AND ANCHORAGES. 1 CUTTING AND PATCHING. DO NOT CUT AND PATCH CONSTRUCTION EXPOSED ON THE EXTERIOR OR IN OCCUPIED SPACES IN APPLIED COATINGS OR FLOOR COVERINGS. H. COUNTERSINK ANCHORAGE DEVISE AT EXPOSED LOCATIONS. CONCEAL WITH SOLID WOOD PLUGS OF SPECIES TO HARDWARE; INCLUDE CUTOUTS, REINFORCEMENT, MORTISING, DRILLING, AND TAPPING, ACCORDING TO THE DOOR HARDWARE A MANNER THAT WOULD, IN ARCHITECT'S OPINION, REDUCE THE BUILDING'S AESTHETIC QUALITIES. REMOVE AND REPLACE 1. APPLY A TROWEL FINISH TO SURFACES TO BE COVERED WITH RESILIENT FLOORING, CARPET, CERAMIC OR QUARRY TILE MATCH SURROUNDING WOOD; FINISH FLUSH WITH SURROUNDING SURFACES. „ SCHEDULE AND TEMPLATES FURNISHED AS SPECIFIED IN DIVISION 8 SECTION DOOR HARDWARE." 3611 SOUTH BRISTOL T. S CONSTRUCTION THAT HAS BEEN CUT AND PATCHED IN A VISUALLY UNSATISFACTORY MANNER. PART 2 - EXECUTION SET OVER A CLEAVAGE MEMBRANE, PAINT, OR ANOTHER THIN-FILM-FlNISH COATING. 2.12 CONCRETE PROTECTING AND CURING (.INSTALL ARCHITECTURAL CABINETRY, FIXTURES AND MILLWORK PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. 2.4 FINISHES A. STEEL FINISH: FACTORY PRIMING FOR FIELD -PAINTED FINISH. �+ SUITE B 2.1 PREPARATION A. GENERAL: PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. SHIM AS REQUIRED USING CONCEALED SHIMS. INSTALL TO A TOLERANCE OF 1/8" IN 8'-0 FOR PLUMB AND LEVEL; AND WITH NO VARIATIONS IN FLUSH OF ADJOINING SURFACES. 1. SHOP PRIMER: MANUFACTURER'S STANDARD, FAST -CURING, LEAD- AND CHROMATE -FREE PRIMER COMPLYING WITH ANSI A. TEMPORARY SUPPORT: PROVIDE TEMPORARY SUPPORT OF WORK TO BE CUT. COMPLY WITH ACI 306.1 FOR COLD -WEATHER PROTECTION AND ACI 301 FOR HOT -WEATHER PROTECTION DURING CURING. B. CURE CONCRETE ACCORDING TO ACI 308.1, BY ONE OR A COMBINATION OF THE FOLLOWING METHODS: J. ANCHOR ARCHITECTURAL CABINETRY, FIXTURES AND MILLWORK TO BLOCKING BUILT-IN OR DIRECTLY ATTACHED TO A250.10 ACCEPTANCE CRITERIA. PART �+ SANTA ANA CA 92704 B. PROTECTION: PROTECT IN -PLACE CONSTRUCTION DURING CUTTING AND PATCHING TO PREVENT DAMAGE. PROVIDE PROTECTION FROM ADVERSE WEATHER CONDITIONS FOR PORTIONS OF PROJECT THAT MIGHT BE EXPOSED DURING CUTTING 1. MOISTURE CURING: KEEP SURFACES CONTINUOUSLY MOIST FOR NOT LESS THAN SEVEN DAYS. SUBSTRATES. SECURE TO GROUNDS AND BLOCKING WITH COUNTERSUNK, CONCEALED FASTENERS AS REQUIRED FOR A 3 T EXECUTION 3.1 INSTALLATION AND PATCHING OPERATIONS. 2. CURING COMPOUND: APPLY UNIFORMLY IN CONTINUOUS OPERATION BY POWER SPRAY OR ROLLER ACCORDING TO COMPLETE INSTALLATION. K. CABINETS: INSTALL WITHOUT DISTORTION SO THAT DOORS AND DRAWERS FIT OPENINGS PROPERLY AND ARE A. PROVIDE DOORS AND FRAMES OF SIZES, THICKNESSES, AND DESIGNS INDICATED. INSTALL STANDARD STEEL DOORS AND PROJECT TEAM C. ADJOINING AREAS: AVOID INTERFERENCE WITH USE OF ADJOINING AREAS OR INTERRUPTION OF FREE PASSAGE TO ADJOINING MANUFACTURER'S WRITTEN INSTRUCTIONS. RECOAT AREAS SUBJECTED TO HEAVY RAINFALL WITHIN THREE HOURS AFTER INITIAL APPLICATION. MAINTAIN CONTINUITY OF COATING AND REPAIR DAMAGE DURING CURING PERIOD. ACCURATELY ALIGNED. ADJUST HARDWARE TO CENTER DOORS AND DRAWERS IN OPENINGS AND TO PROVIDE FRAMES PLUMB, RIGID, PROPERLY ALIGNED, AND SECURELY FASTENED IN PLACE; COMPLY WITH DRAWINGS AND OWNER'S PROJECT MANAGER AREAS. 2.2 PERFORMANCE A. AFTER CURING PERIOD HAS ELAPSED, REMOVE CURING COMPOUND WITHOUT DAMAGING CONCRETE SURFACES BY UNENCUMBERED OPERATION. COMPLETE THE INSTALLATION OF HARDWARE AND ACCESSORY ITEMS AS INDICATED. L. TOPS: ANCHOR SECURELY TO BASE UNITS AND OTHER SUPPORT SYSTEMS. MANUFACTURER'S WRITTEN INSTRUCTIONS. B. STANDARD STEEL FRAMES: INSTALL STANDARD STEEL FRAMES FOR DOORS AND OTHER OPENINGS, OF SIZE AND PROFILE TRAMMELL CROW A. GENERAL: EMPLOY SKILLED WORKERS TO PERFORM CUTTING AND PATCHING. PROCEED WITH CUTTING AND PATCHING AT METHOD RECOMMENDED BY CURING COMPOUND MANUFACTURER UNLESS MANUFACTURER CERTIFIES CURING 3.3 ADJUSTMENT, CLEANING, FINISHING AND PROTECTION: INDICATED. COMPLY WITH SDI 105. THE EARLIEST FEASIBLE TIME, AND COMPLETE WITHOUT DELAY. COMPOUND WILL NOT INTERFERE WITH BONDING OF FLOOR COVERING USED ON PROJECT. A. REPAIR DAMAGED AND DEFECTIVE PLASTIC LAMINATE CABINETRY WHERE POSSIBLE TO ELIMINATE DEFECTS FUNCTIONALLY 1.SET FRAMES ACCURATELY IN POSITION; PLUMBED, ALIGNED, AND BRACED SECURELY UNTIL PERMANENT ANCHORS ARE SPRINT PCS PROJECT MANAGER = B. CUTTING: CUT IN -PLACE CONSTRUCTION BY SAWING, DRILLING, BREAKING, CHIPPING, GRINDING, AND SIMILAR OPERATIONS, AND VISUALLY; WHERE NOT POSSIBLE TO REPAIR REPLACE PLASTIC LAMINATE CABINETRY. ADJUST JOINERY FOR UNIFORM SET. AFTER WALL CONSTRUCTION IS COMPLETE, REMOVE TEMPORARY BRACES, LEAVING SURFACES SMOOTH AND 6100 SPRINT PARKWAY INCLUDING EXCAVATION, USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS RETAINED OR ADJOINING CONSTRUCTION. IF SECTION 05500 - METAL FABRICATIONS APPEARANCE. UNDAMAGED. POSSIBLE, REVIEW PROPOSED PROCEDURES WITH ORIGINAL INSTALLER; COMPLY WITH ORIGINAL INSTALLER'S WRITTEN PART 1 - PRODUCT B. CLEAN, LUBRICATE AND ADJUST HARDWARE. A. AT FIRE -PROTECTION -RATED OPENINGS, INSTALL FRAMES ACCORDING TO NFPA 80. Mailstop: KSOPHKO410-4A554 RECOMMENDATIONS. 1.1 MATERIALS C. CLEAN CABINETRY, WOODWORK AND FIXTURES ON EXPOSED AND SEMI -EXPOSED SURFACES. TOUCH-UP 2. METAL -STUD PARTITIONS: SOLIDLY PACK MINERAL -FIBER INSULATION BEHIND FRAMES. OVERLAND PARK, KS 66251 C. PATCHING: PATCH CONSTRUCTION BY FILLING, REPAIRING, REFINISHING, CLOSING UP, AND SIMILAR OPERATIONS FOLLOWING A. METAL SURFACES, GENERAL: PROVIDE MATERIALS WITH SMOOTH, FLAT SURFACES WITHOUT BLEMISHES. SHOP -APPLIED FINISHES TO RESTORE DAMAGED OR SOILED AREAS. REMOVE ALL PROTECTIVE SURFACE MATERIAL. 3. MASONRY WALLS: COORDINATE INSTALLATION OF FRAMES TO ALLOW FOR SOLIDLY FILLING SPACE BETWEEN FRAMES AND PHONE 913 315- 1 ( ) 5 10 PERFORMANCE OF OTHER WORK. PATCH WITH R P WT DURABLE SEAMS THAT ARE AS INVISIBLE AS POSSIBLE. PROVIDE MATERIALS B. FERROUS METALS: D. COMPLETE THE FINISHING WORK SPECIFIED AS WORK OF THIS SECTION, TO WHATEVER EXTENT NOT COMPLETED AT „ MASONRY WITH MORTAR AS SPECIFIED IN DIVISION 4 SECTION "UNIT MASONRY ASSEMBLIES. CONTACT: RON GERARD ron.d.gerard®mail.sprint,com AND COMPLY WITH INSTALLATION REQUIREMENTS SPECIFIED IN OTHER SECTIONS. 1. STEEL PLATES, SHAPES, AND BARS: ASTM A 36/A 36M. SHOP OR PRIOR TO INSTALLATION. 4. CONCRETE WALLS: SOLIDLY FILL SPACE BETWEEN FRAMES AND CONCRETE WITH GROUT. INSTALL GROUT IN LIFTS AND D. CLEANING: CLEAN AREAS AND SPACES WHERE CUTTING AND PATCHING ARE PERFORMED. COMPLETELY REMOVE PAINT, 2. STAINLESS -STEEL BARS AND SHAPES: ASTM A 276, TYPE 304 E. PROVIDE FINAL PROTECTION AND MAINTAIN CONDITIONS, IN A MANNER ACCEPTABLE TO FABRICATOR AND INSTALLER, TAKE PRECAUTIONS, INCLUDING BRACING FRAMES, TO ENSURE THAT FRAMES ARE NOT DEFORMED OR DAMAGED BY MORTAR, OILS, PUTTY, AND SIMILAR MATERIALS. 3. ROLLED -STAINLESS -STEEL FLOOR PLATE: ASTM A 793. 4. STEEL TUBING: ASTM A 500, COLD -FORMED STEEL TUBING. WHICH ENSURES ARCHITECTURAL CABINETRY, FIXTURES AND MILLWORK BEING WITHOUT DAMAGE OR DETERIORATION AT TIME OF SUBSTANTIAL COMPLETION. GROUT FORCES. C. STANDARD STEEL DOORS: FIT HOLLOW -METAL DOORS ACCURATELY IN FRAMES. SHIM AS NECESSARY. ARCHITECT CARRILLO ARCHITECTURAL GROUP, INC. 5. STEEL PIPE: ASTM A 53/A 53M, STANDARD WEIGHT (SCHEDULE 40), UNLESS ANOTHER WEIGHT IS INDICATED OR F. CLEAN WORK AND REMOVE ALL TRASH, DEBRIS, PACKING, ETC. RESULTING FROM THAT WORK ON A REGULAR BASIS. 1. FIRE -RATED DOORS: INSTALL DOORS WITH CLEARANCES ACCORDING TO NFPA 80. SECTION 01732 -SELECTIVE DEMOLITION REQUIRED BY STRUCTURAL LOADS. G. FINAL CLEANING SHALL BE DONE BY A PROFESSIONAL CLEANER. ALL SURFACES AND FINISHES SHALL BE LEFT FREE D. FINAL ADJUSTMENTS: CHECK AND READJUST OPERATING HARDWARE ITEMS IMMEDIATELY BEFORE FINAL INSPECTION. LEAVE 11231 GOLD EXPRESS DR., SUITE 103 PART 1 - GENERAL 1.2 FASTENERS OF MARKS, BLEMISHES, DUST, OVERSPRAY, PAINT SPILLS, ETC. WORK IN COMPLETE AND PROPER OPERATING CONDITION. REMOVE AND REPLACE DEFECTIVE WORK, INCLUDING STANDARD 1.1 SUMMARY A. GENERAL: TYPE 304 STAINLESS -STEEL FASTENERS FOR EXTERIOR USE AND ZINC -PLATED FASTENERS WITH COATING 1. CLEAN ALL PLASTIC LAMINATES, COUNTERTOPS, AND METAL TRIM WITH NON-ABRASIVE CLEANER. STEEL DOORS OR FRAMES THAT ARE WARPED, BOWED, OR OTHERWISE UNACCEPTABLE. GOLD RIVER, CA 95670 A. THIS SECTION INCLUDES THE FOLLOWING: COMPLYING WITH ASTM B 633, CLASS FE/ZN 5, AT EXTERIOR WALLS. PROVIDE STAINLESS -STEEL FASTENERS FOR 2. CLEAN ALL GLASS AND MIRRORS WITH AMMONIA -TYPE NON -STREAKING GLASS CLEANER. E. PRIME -COAT TOUCHUP: IMMEDIATELY AFTER ERECTION, SAND SMOOTH RUSTED OR DAMAGED AREAS OF PRIME COAT AND PHONE: (916) 266-6000 1. DEMOLITION AND REMOVAL OF SELECTED PORTIONS OF BUILDING OR STRUCTURE. FASTENING ALUMINUM. SELECT FASTENERS FOR TYPE, GRADE, AND CLASS REQUIRED. 3. DAMP WIPE ALL FIXTURES, INCLUDING LIGHT FIXTURES. APPLY TOUCHUP OF COMPATIBLE AIR -DRYING PRIMER. FAX: (916) 266-6006 2. SALVAGE OF EXISTING ITEMS TO BE REUSED OR RECYCLED. B. CAST -IN -PLACE ANCHORS IN CONCRETE: THREADED OR WEDGE TYPE; GALVANIZED FERROUS CASTINGS, EITHER ASTM A 4. REMOVE LABELS, EXCEPT THOSE REQUIRED TO DEMONSTRATE COMPLIANCE WITH BUILDING CODES, FIRE RATINGS, AND CONTACT: HATE HENINGER nateheninger@corrilloag.com 1.2 DEFINITIONS 47/A 47M MALLEABLE IRON OR ASTM A 27/A 27M CAST STEEL. PROVIDE BOLTS, WASHERS, AND SHIMS AS NEEDED, TESTING. ALSO REMOVE ALL GLUE AND RESIDUE REMAINING ON THE SURFACE. A. REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF THEM OFF -SITE, UNLESS INDICATED TO HOT -DIP GALVANIZED PER ASTM A 153/A 153M. 5. CARPET CLEANING - ALL CARPET, INCLUDING BASE, SHALL BE VACUUMED WHERE SPOTTED OR STAINED, CARPETING BE REMOVED AND SALVAGED OR REMOVED AND REINSTALLED. 1.3 MISCELLANEOUS MATERIALS SHALL BE STEAM CLEANED. SECTION 08211 - FLUSH WOOD DOORS MEP ENGINEERS B. REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND DELIVER THEM TO OWNER. A. UNIVERSAL SHOP PRIMER: FAST -CURING, LEAD- AND CHROMATE -FREE, UNIVERSAL MODIFIED -ALKYD PRIMER COMPLYING 6. REMOVE PROTECTIVE COVERINGS AND TAGS. PART 1 - GENERAL- 1.1 SUMMARY HENDERSON ENGINEERS C. REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONSTRUCTION, PREPARE THEM FOR REUSE, AND REINSTALL THEM WITH MPI #79. 7. REMOVE AND DISPOSE OF ALL TRASH, SCRAPES, PACKING, ETC. DISPOSAL SHALL BE IN ACCORDANCE WITH THE WHERE INDICATED. B. GALVANIZING REPAIR PAINT: SSPC-PAINT 20, HIGH -ZINC -DUST -CONTENT PAINT FOR REGALVANIZING WELDS IN STEEL. LANDLORD'S REQUIREMENTS. A. THIS SECTION INCLUDES SOLID CORE DOORS AS FOLLOWS: 1. DOORS WITH HARDBOARD FACES. 8325 LENEXA DRIVE, SUITE 400 D. EXISTING TO REMAIN: EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT TO BE REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE REMOVED, REMOVED AND SALVAGED, OR REMOVED AND REINSTALLED. C. NONSHRINK, NONMETALLIC GROUT. FACTORY -PACKAGED, NONSTAINING, NONCORROSIVE, NONGASEOUS GROUT COMPLYING SECTION 07620 - SHEET METAL FLASHING AND TRIM 1.2 QUALITY ASSURANCE LENEXA, KS 66214 1.3 SUBMITTALS WITH ASTM C 1107. D. CONCRETE MATERIALS AND PROPERTIES: COMPLY WITH REQUIREMENTS IN DIVISION 3 SECTION "CAST -IN CONCRETE' PART 1 - GENERAL A. QUALITY STANDARD: COMPLY AWI'S "ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED." PHONE: (913) 307-5464 A. SCHEDULE OF SELECTIVE DEMOLITION ACTIVITIES: INDICATE DETAILED SEQUENCE OF SELECTIVE DEMOLITION AND REMOVAL -PLACE FOR NORMAL AIR READY 1.1 QUALITY ASSURANCE B. FIRE -RATED WOOD DOORS: DOORS THAT ARE LISTED AND LABELED BY A TESTING AND INSPECTING AGENCY ACCEPTABLE TO _ FAX: (913) 307 5400 WORK, WITH STARTING AND ENDING DATES FOR EACH ACTIVITY, INTERRUPTION OF UTILITY SERVICES, USE OF ELEVATOR AND -WEIGHT, -ENTRAINED, -MIX CONCRETE WITH A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 3500 A. SHEET METAL FLASHING AND TRIM STANDARD: COMPLY WITH SMACNA'S "ARCHITECTURAL SHEET METAL MANUAL." CONFORM AUTHORITIES HAVING JURISDICTION, FOR FIRE RATINGS INDICATED. STAIRS, AND LOCATIONS OF TEMPORARY PARTITIONS AND MEANS OF EGRESS. PSI, UNLESS OTHERWISE INDICATED. TO DIMENSIONS AND PROFILES SHOWN UNLESS MORE STRINGENT REQUIREMENTS ARE INDICATED. PART 2 - PRODUCTS CONTACT: TREVOR JWNES trevor.jones®hendersonengineers.com 1.4 QUALITY ASSURANCE 1.4 FINISHES PART 2 - PRODUCTS 2.1 DOOR CONSTRUCTION A. DEMOLITION FIRM QUALIFICATIONS: AN EXPERIENCED FIRM THAT HAS SPECIALIZED IN DEMOLITION WORK SIMILAR IN MATERIAL A. COMPLY WITH NAAMM'S "METAL FINISHES MANUAL FOR ARCHITECTURAL AND METAL PRODUCTS" FOR RECOMMENDATIONS FOR 2.1 SHEET METALS A. DOORS FOR OPAQUE FINISH: LANDLORD AND EXTENT TO THAT INDICATED FOR THIS PROJECT. APPLYING AND DESIGNATING FINISHES. FINISH METAL FABRICATIONS AFTER ASSEMBLY. B. STEEL A. PROVIDE WALL AND ROOF CUTS AND MISCELLANEOUS PENETRATIONS AND PATCH EXISTING ROOFING SYSTEM AS REQUIRED BY 1. GRADE: CUSTOM. INVESTCORP /ORANGE BRISTOL, LP B. REFRIGERANT RECOVERY TECHNICIAN QUALIFICATIONS: CERTIFIED BY AN EPA -APPROVED CERTIFICATION PROGRAM. AND IRON FINISHES: EXISTING CONDITIONS AND NEW WORK. 2. FACES FOR INTERIOR DOORS: ANY CLOSED -GRAIN HARDWOOD OF MILL OPTION. C. REGULATORY REQUIREMENTS: COMPLY WITH GOVERNING EPA NOTIFICATION REGULATIONS BEFORE BEGINNING SELECTIVE 1. HOT -DIP GALVANIZE ITEMS AS INDICATED TO COMPLY WITH ASTM A 123/A 123M OR ASTM A 153/A 153M AS 2.2 MISCELLANEOUS MATERIALS 2.2 FABRICATION L`- DEMOLITION. COMPLY WITH HAULING AND DISPOSAL REGULATIONS OF AUTHORITIES HAVING JURISDICTION. APPLICABLE. A. GENERAL: PROVIDE MATERIALS AND TYPES OF FASTENERS, SOLDER, WELDING RODS, PROTECTIVE COATINGS, SEPARATORS, A. FABRICATE DOORS IN SIZES INDICATED FOR PROJECT -SITE FITTING. 280 PARK AVE, 36TH FLOOR D. STANDARDS: COMPLY WITH ANSI A10.6 AND NFPA 241. 2. SHOP PRIMING: APPLY SHOP PRIMER TO UNCOATED SURFACES OF METAL FABRICATIONS, EXCEPT THOSE WITH SEALANTS, AND OTHER MISCELLANEOUS ITEMS AS REQUIRED FOR COMPLETE SHEET METAL FLASHING AND TRIM INSTALLATION. B. FACTORY FIT DOORS TO SUIT FRAME -OPENING SIZES INDICATED. COMPLY WITH CLEARANCE REQUIREMENTS OF REFERENCED NEW YORK, NY 10017 1.5 PROJECT CONDITIONS GALVANIZED FINISHES AND THOSE TO BE EMBEDDED IN CONCRETE, SPRAYED -ON FIREPROOFING, OR MASONRY, TO "PAINT 2.3 FABRICATION, GENERAL QUALITY STANDARD FOR FITTING. COMPLY WITH REQUIREMENTS IN NFPA 80 FOR FIRE -RATED DOORS. PHONE: 212 577-1414 A. NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS BEFORE PROCEEDING WITH SELECTIVE COMPLY WITH SSPC-PA 1, APPLICATION SPECIFICATION NO. 1: SHOP, FIELD, AND MAINTENANCE PAINTING," FOR A. GENERAL: CUSTOM FABRICATE SHEET METAL FLASHING AND TRIM TO COMPLY WITH RECOMMENDATIONS IN SMACNA'S "ARCHITECTURAL C. FACTORY MACHINE DOORS FOR HARDWARE THAT IS NOT SURFACE APPLIED. CONTACT( HEATHER MUTTERPERL DEMOLITION. SHOP PAINTING. SHEET METAL MANUAL" THAT APPLY TO DESIGN, DIMENSIONS, METAL, AND OTHER CHARACTERISTICS OF ITEM 2.3 SHOP PRIMING B. HAZARDOUS MATERIALS: IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN THE WORK. INDICATED. SHOP FABRICATE ITEMS WHERE PRACTICABLE. OBTAIN FIELD MEASUREMENTS FOR ACCURATE FIT BEFORE SHOP A. DOORS FOR OPAQUE FINISH: SHOP PRIME FACES AND EDGES OF DOORS, INCLUDING CUTOUTS, WITH ONE COAT OF WOOD 1. IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY SECTION 06100 -ROUGH CARPENTRY FABRICATION. PRIMER. NOTIFY ARCHITECT AND OWNER. OWNER WILL REMOVE HAZARDOUS MATERIALS UNDER A SEPARATE CONTRACT. PART 1 - GENERAL PART 3 - EXECUTION PART 3 - EXECUTION C. STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON -SITE IS NOT PERMITTED. D. UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE 1.1 SUMMARY A. THIS SECTION INCLUDES THE FOLLOWING: 3.1 INSTALLATION, GENERAL A. GENERAL: ANCHOR SHEET METAL FLASHING AND TRIM AND OTHER COMPONENTS OF THE WORK SECURELY IN PLACE, WITH 3.1 INSTALLATION A. INSTALL DOORS TO COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, REFERENCED QUALITY STANDARD, AND AS DURING SELECTIVE DEMOLITION OPERATIONS, 1. WOOD FRAMING. PROVISIONS FOR THERMAL AND STRUCTURAL MOVEMENT, USE FASTENERS, SOLDER, WELDING RODS, PROTECTIVE COATINGS, INDICATED. 1. MAINTAIN FIRE -PROTECTION FACILITIES IN SERVICE DURING SELECTIVE DEMOLITION OPERATIONS. 2. WOOD BLOCKING. SEPARATORS, SEALANTS, AND OTHER MISCELLANEOUS ITEMS AS REQUIRED TO COMPLETE SHEET METAL FLASHING AND TRIM 1. INSTALL FIRE -RATED DOORS IN CORRESPONDING FIRE -RATED FRAMES ACCORDING TO NFPA 80. 1.6 WARRANTY 3. WOOD NAILERS. SYSTEM. B. JOB -FITTED DOORS: ALIGN AND FIT DOORS IN FRAMES WITH UNIFORM CLEARANCES AND BEVELS; DO NOT TRIM STILES AND A. EXISTING WARRANTIES: REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND SURFACES CUT OR DAMAGED DURING 4. WOOD FURRING. B. METAL PROTECTION: WHERE DISSIMILAR METALS WILL CONTACT EACH OTHER OR CORROSIVE SUBSTRATES, PROTECT AGAINST RAILS IN EXCESS OF LIMITS SET BY MANUFACTURER OR PERMITTED FOR FIRE -RATED DOORS. MACHINE DOORS FOR SELECTIVE DEMOLITION, BY METHODS AND WITH MATERIALS SO AS NOT TO VOID EXISTING WARRANTIES, 1.2 WOOD PRODUCTS, GENERAL GALVANIC ACTION BY PAINTING CONTACT SURFACES WITH BITUMINOUS COATING OR BY OTHER PERMANENT SEPARATION AS HARDWARE. SEAL CUT SURFACES AFTER FITTING AND MACHINING. PART 2 - EXECUTION A. LUMBER: DOC PS 20 AND APPLICABLE RULES OF LUMBER GRADING AGENCIES CERTIFIED BY THE AMERICAN LUMBER RECOMMENDED BY FABRICATOR OR MANUFACTURERS OF DISSIMILAR METALS. 1. COMPLY WITH NFPA 80 FOR FIRE -RATED DOORS. 2.1 EXAMINATION STANDARDS COMMITTEE BOARDD OF R OF REVIEW. C. INSTALL EXPOSED SHEET METAL FLASHING AND TRIM WITHOUT EXCESSIVE OIL CANNING, BUCKLING, AND TOOL MARKS. C. FACTORY -FITTED DOORS: ALIGN IN FRAMES FOR UNIFORM CLEARANCE AT EACH EDGE. Lei A. VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED. 1. FACTORY MARK EACH PIECE OF LUMBER WITH GRADE STAMP OF GRADING AGENCY. D. INSTALL SHEET METAL FLASHING AND TRIM TRUE TO LINE AND LEVELS INDICATED. PROVIDE UNIFORM, NEAT SEAMS WITH B. SURVEY EXISTING CONDITIONS AND CORRELATE WITH REQUIREMENTS INDICATED TO DETERMINE EXTENT OF SELECTIVE 2. PROVIDE DRY LUMBER WITH 19 PERCENT MAXIMUM MOISTURE CONTENT AT TIME OF DRESSING FOR 2-INCH NOMINAL MINIMUM EXPOSURE OF SOLDER, WELDS, AND ELASTOMERIC SEALANT. SECTION 08411 - ALUMINUM -FRAMED ENTRANCES AND STOREFRONTS DEMOLITION REQUIRED. THICKNESS OR LESS, UNLESS OTHERWISE INDICATED. E. INSTALL SHEET METAL FLASHING AND TRIM TO FIT SUBSTRATES AND TO RESULT IN WATERTIGHT PERFORMANCE. VERIFY PART 1 - GENERAL C. WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL ELEMENTS THAT CONFLICT WITH INTENDED FUNCTION OR 3. ORIENTED STRAND BOARD: DOC PS 2. SHAPES AND DIMENSIONS OF SURFACES TO BE COVERED BEFORE FABRICATING SHEET METAL. 1.1 SUMMARY DESIGN ARE ENCOUNTERED, INVESTIGATE AND MEASURE THE NATURE AND EXTENT OF CONFLICT. PROMPTLY SUBMIT A 1.3 FIRE -RETARDANT -TREATED MATERIALS F. SEAL JOINTS WITH ELASTOMERIC SEALANT AS REQUIRED FOR WATERTIGHT CONSTRUCTION. A. THIS SECTION INCLUDES THE FOLLOWING: WRITTEN REPORT TO ARCHITECT. A. GENERAL: WHERE FIRE -RETARDANT -TREATED MATERIALS ARE INDICATED, PROVIDE MATERIALS THAT COMPLY WITH SECTION 07920 - JOINT SEALANTS 1. EXTERIOR ALUMINUM -FRAMED STOREFRONTS. 2.2 UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS PERFORMANCE REQUIREMENTS IN [AWPA C20 (LUMBER)] [AND] [AWPA C27 (PLYWOOD)]. IDENTIFY PART 1 - GENERAL 2. EXTERIOR MANUAL -SWING ALUMINUM DOORS. A. EXISTING SERVICES/SYSTEMS: MAINTAIN SERVICES/SYSTEMS INDICATED TO REMAIN AND PROTECT THEM AGAINST DAMAGE FIRE -RETARDANT -TREATED WOOD WITH APPROPRIATE CLASSIFICATION MARKING OF UL, U.S. TESTING, TIMBER PRODUCTS 1.1 SUMMARY 1.2 PERFORMANCE REQUIREMENTS DURING SELECTIVE DEMOLITION OPERATIONS. INSPECTION, OR ANOTHER TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. A. THIS SECTION INCLUDES JOINT SEALANTS FOR THE FOLLOWING APPLICATIONS, INCLUDING THOSE SPECIFIED BY REFERENCE TO A. GENERAL: PROVIDE ALUMINUM -FRAMED SYSTEMS, INCLUDING ANCHORAGE, CAPABLE OF WITHSTANDING, WITHOUT FAILURE, B. SERVICE/SYSTEM REQUIREMENTS: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF INDICATED UTILITY SERVICES AND 1.4 DIMENSION LUMBER THIS SECTION: APPLICATIONS: THE EFFECTS OF THE FOLLOWING: MECHANICAL/ELECTRICAL SYSTEMS SERVING AREAS TO BE SELECTIVELY DEMOLISHED. A. GENERAL: OF GRADES INDICATED ACCORDING TO THE AMERICAN LUMBER STANDARDS COMMITTEE NATIONAL GRADING RULE 1. EXTERIOR JOINTS IN VERTICAL SURFACES AND HORIZONTAL NONTRAFFIC SURFACES. 1. STRUCTURAL LOADS. 2. THERMAL MOVEMENTS. 2.3 SELECTIVE DEMOLITION PROVISIONS OF THE GRADING AGENCY INDICATED, 2. EXTERIOR JOINTS IN HORIZONTAL TRAFFIC SURFACES. 3. MOVEMENTS OF SUPPORTING STRUCTURE INDICATED ON DRAWINGS INCLUDING, BUT NOT LIMITED TO, STORY DRIFT AND A. GENERAL: DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND 1.5 PLYWOOD BACKING PANELS 3. INTERIOR JOINTS IN VERTICAL SURFACES AND HORIZONTAL NONTRAFFIC SURFACES. DEFLECTION FROM UNIFORMLY DISTRIBUTED AND CONCENTRATED LIVE LOADS. AS INDICATED. A. TELEPHONE AND ELECTRICAL EQUIPMENT BACKING PANELS: DOC PS 1, EXPOSURE 1, C-D PLUGGED, FIRE -RETARDANT 4. INTERIOR JOINTS IN HORIZONTAL TRAFFIC SURFACES. 4. DIMENSIONAL TOLERANCES OF BUILDING FRAME AND OTHER ADJACENT CONSTRUCTION. 2.4 DISPOSAL OF DEMOLISHED MATERIALS A. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TREATED, IN THICKNESS INDICATED. PART 2 - EXECUTION 1.2 PERFORMANCE REQUIREMENTS A. PROVIDE ELASTOMERIC JOINT SEALANTS THAT ESTABLISH AND MAINTAIN WATERTIGHT AND AIRTIGHT CONTINUOUS JOINT SEALS 5. WIND LOADS: FABRICATE ENTRANCES TO WITHSTAND WIND PRESSURE LOADING OF 20 LBS. PER SQ. FT., WIND SPEEDS 4 r._ TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN 2.1 INSTALLATION WITHOUT STAINING OR DETERIORATING JOINT SUBSTRATES. OF 75 MPH, EXPOSURE C, IMPORTANCE FACTOR OF 100 ON GROSS AREA OF FRAMES, DOORS, AND GLASS, ACTING INWARD AND ALSO ACTING OUTWARD AN EPA -APPROVED LANDFILL. B. DISPOSAL: TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY AND LEGALLY DISPOSE OF THEM. 2A. CLEANING A. SET ROUGH CARPENTRY TO REQUIRED LEVELS AND LINES, WITH MEMBERS PLUMB, TRUE TO LINE, CUT, AND FITTED. FIT ROUGH CARPENTRY TO OTHER CONSTRUCTION; SCRIBE AND COPE AS NEEDED FOR ACCURATE FIT. LOCATE [FURRING,] NAILERS, BLOCKING, GROUNDS, AND SIMILAR SUPPORTS TO COMPLY WITH REQUIREMENTS FOR ATTACHING OTHER [ ] B. PROVIDE JOINT SEALANTS FOR INTERIOR APPLICATIONS THAT ESTABLISH AND MAINTAIN AIRTIGHT AND WATER-RESISTANT CONTINUOUS JOINT SEALS WITHOUT STAINING OR DETERIORATING JOINT SUBSTRATES. PART 2 - PRODUCTS 1.3 SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. B. SHOP DRAWINGS: INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ATTACHMENTS TO OTHER WORK. A. CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT, AND DEBRIS CAUSED BY SELECTIVE DEMOLITION 2.1 MATERIALS, GENERAL EIV1477C)l CONSTRUCTION. 1. INCLUDE STRUCTURAL ANALYSIS DATA SIGNED AND SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER RESPONSIBLE OPERATIONS. RETURN ADJACENT AREAS TO CONDITION EXISTING BEFORE SELECTIVE DEMOLITION OPERATIONS BEGAN. B. APPLY FIELD TREATMENT COMPLYING WITH AWPA M4 TO CUT SURFACES OF PRESERVATIVE -TREATED LUMBER AND PLYWOOD. A. COMPATIBILITY: PROVIDE JOINT SEALANTS, BACKINGS, AND OTHER RELATED MATERIALS THAT ARE COMPATIBLE WITH ONE FOR THEIR PREPARATION. C. SECURELY ATTACH ROUGH CARPENTRY WORK TO SUBSTRATE BY ANCHORING AND FASTENING AS REQUIRED, COMPLYING WITH ANOTHER AND WITH JOINT SUBSTRATES UNDER CONDITIONS OF SERVICE AND APPLICATION, AS DEMONSTRATED BY SEALANT 2, FOR ENTRANCES, PROVIDE HARDWARE AS INDICATED IN HARDWARE SCHEDULE. THE FOLLOWING: MANUFACTURER, BASED ON TESTING AND FIELD EXPERIENCE. PART 2 - PRODUCTS SECTION 03300 -CAST-IN-PLACE CONCRETE PART 1 - GENERAL 1. CABO NER-272 FOR POWER -DRIVEN FASTENERS. 2. PUBLISHED REQUIREMENTS OF METAL FRAMING ANCHOR MANUFACTURER. 2.2 ELASTOMERIC JOINT SEALANTS A. TWO -COMPONENT POLYSULFIDE SEALANT: COMPLY WITH FS-TT-S-00227, CLASS A, TYPE 2 (NON -SAG) UNLESS TYPE 1 2.1 MANUFACTURERS A. AVAILABLE MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS. 1.1 SUMMARY (SELF -LEVELING) RECOMMENDED BY MANUFACTURER FOR APPLICATION SHOWN. B. MATCH EXISTING STOREFRONT OR BUILDING STANDARD UNLESS NOTED OTHERWISE, A. THIS SECTION SPECIFIES CAST -IN PLACE CONCRETE, INCLUDING FORMWORK, REINFORCEMENT, CONCRETE MATERIALS, MIXTURE 2.2 DOORS DESIGN, PLACEMENT PROCEDURES, AND FINISHES. SECTION 06405 ARCHITECTURAL CABINETRY, FIXTURES AND MILLWORK B. ACRYLIC LATEX SEALANT: ASTM C 834, PERMANENTLY FLEXIBLE EMULSION TYPE, NON -STAINING AND NON -BLEEDING; A. DOORS: MANUFACTURER'S STANDARD GLAZED DOORS, FOR MANUAL SWING OPERATION. 1.2 QUALITY ASSURANCE RECOMMENDED BY MANUFACTURER FOR GENERAL INTERIOR EXPOSURE. 1. MATCH EXISTING STOREFRONT OR BUILDING STANDARD UNLESS NOTED OTHERWISE. A. MANUFACTURER QUALIFICATIONS: A FIRM EXPERIENCED IN MANUFACTURING READY -MIXED CONCRETE PRODUCTS AND THAT PART 1 - GENERAL C. SINGLE COMPONENT SANITARY SILICON RUBBER: MOLD/MILDEW RESISTANT, ACID TYPE SEALANT FOR APPLICATION TO B. DOOR HARDWARE: AS SPECIFIED IN DIVISION 8 SECTION "DOOR HARDWARE." COMPLIES WITH ASTM C 94/C 94M REQUIREMENTS FOR PRODUCTION FACILITIES AND EQUIPMENT, NON -POROUS SEALANT BOND SURFACES. 2.3 ALUMINUM FINISHES PART 2 - PRODUCTS 1.1 SECTION INCLUDES: D. RELATED MATERIALS: PROVIDE NON -ABSORBENT AND NON -STAINING PRIMERS, JOINT BACKERS, BOND -PREVENTIVE TAPE, A. MATCH EXISTING STOREFRONT OR BUILDING STANDARD UNLESS NOTED OTHERWISE. U 2.1 FORM -FACING MATERIALS AND MASKING TAPE MATERIALS WHICH HAVE BEEN TESTED FOR COMPATIBILITY OR DURABILITY, WHICH ARE SPECIFICALLY PART 3 - EXECUTION A. SMOOTH -FORMED FINISHED CONCRETE: FORM -FACING PANELS THAT WILL PROVIDE CONTINUOUS, TRUE, AND SMOOTH A. PREFINISHED SHOP FABRICATED WOOD CASEWORK: INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: RECOMMENDED FOR USE BY THE MANUFACTURER. 3.1 INSTALLATION CONCRETE SURFACES. FURNISH IN LARGEST PRACTICABLE SIZES TO MINIMIZE NUMBER OF JOINTS. 1. MILLWORK. 2.3 PREPARATION A. GENERAL: 2.2 STEEL REINFORCEMENT 2. GLASSWORK WHICH IS PART OF CABINETS, FIXTURES AND MILLWORK, AS SPECIFIED IN THIS SECTION. A. SURFACE CLEANING OF JOINTS: CLEAN OUT JOINTS IMMEDIATELY BEFORE INSTALLING JOINT SEALANTS. 1. FIT JOINTS TO PRODUCE HAIRLINE JOINTS FREE OF BURRS AND DISTORTION. 1 PLAN CHECK COMMENTS 1 /20/05 A. PLAIN -STEEL WELDED WIRE REINFORCEMENT: ASTM A 185, PLAIN, FABRICATED FROM AS -DRAWN STEEL WIRE INTO FLAT 3. METALS WHICH ARE PART OF CABINETS, FIXTURES AND MILLWORK, AS SPECIFIED IN THIS SECTION. 1. REMOVE ALL FOREIGN MATERIAL FROM JOINT SUBSTRATES THAT COULD INTERFERE WITH ADHESION OF JOINT SEALANT. 2. RIGIDLY SECURE NONMOVEMENT JOINTS. O ISSUED FOR PERMIT AND BID 1 /7/04 SHEETS. 4. HARDWARE WHICH IS PART OF CABINETS, FIXTURES AND. SECTION 08111 - STANDARD STEEL DOORS AND FRAMES 3. INSTALL ANCHORS WITH SEPARATORS AND ISOLATORS TO PREVENT METAL CORROSION AND ELECTROLYTIC DETERIORATION. B. BAR SUPPORTS: BOLSTERS, CHAIRS, SPACERS, AND OTHER DEVICES FOR SPACING, SUPPORTING, AND FASTENING 5. GROUNDS, BLOCKING AND BACKING. PART 1 - GENERAL 4. SEAL JOINTS WATERTIGHT, UNLESS OTHERWISE INDICATED. No. Revisions / Submissions Date REINFORCING BARS AND WELDED WIRE REINFORCEMENT IN PLACE. MANUFACTURE BAR SUPPORTS FROM STEEL WIRE, "MANUAL 6. ALL PRIMER, TOUCH-UP AND FINISH LACQUER PAINTS PAINT AS REQUIRED TO ENSURE A CONSISTENT SEAMLESS 1.1 SUMMARY B. METAL PROTECTION: PLASTIC, OR PRECAST CONCRETE ACCORDING TO CRSI'S OF STANDARD PRACTICE." 2.3 CONCRETE MATERIALS A. CEMENTITIOUS MATERIAL: USE THE FOLLOWING CEMENTTTIOUS MATERIALS, OF THE SAME TYPE, BRAND, AND SOURCE, PAINT FINISH. 7. COORDINATION OF ELECTRICAL CONNECTIONS. 1.2 DEFINITIONS: A. THIS SECTION INCLUDES STANDARD HOLLOW -METAL STEEL DOORS AND FRAMES. PART 2 - PRODUCTS 2.1 STANDARD STEEL DOORS 1. WHERE ALUMINUM WILL CONTACT DISSIMILAR METALS, PROTECT AGAINST GALVANIC ACTION BY PAINTING CONTACT SURFACES WITH PRIMER OR BY APPLYING SEALANT OR TAPE OR INSTALLING NONCONDUCTIVE SPACERS AS RECOMMENDED BY MANUFACTURER FOR THIS PURPOSE. THROUGHOUT PROJECT: A. ARCHITECTURAL CABINETRY, FIXTURES AND MILLWORK INCLUDES WOOD FURRING, BLOCKING, SHIMS, AND HANGING STRIPS A. GENERAL: PROVIDE DOORS OF DESIGN INDICATED, NOT LESS THAN THICKNESS INDICATED; FABRICATED WITH SMOOTH 2. WHERE ALUMINUM WILL CONTACT CONCRETE OR MASONRY, PROTECT AGAINST CORROSION BY PAINTING CONTACT CARRILLO 1. PORTLAND CEMENT: ASTM C 150, TYPE [I] FOR INSTALLING WOODWORK ITEMS UNLESS CONCEALED WITHIN OTHER CONSTRUCTION PRIOR TO WOODWORK INSTALLATION. SURFACES, WITHOUT VISIBLE JOINTS OR SEAMS ON EXPOSED FACES. COMPLY WITH ANSI A250.8. SURFACES WITH BITUMINOUS PAINT, B. NORMAL -WEIGHT AGGREGATES: ASTM C 33, GRADED, 3/4-INCH NOMINAL MAXIMUM COARSE -AGGREGATE SIZE. 1.3 QUALITY ASSURANCE: 1. CORE CONSTRUCTION: MANUFACTURER'S STANDARD KRAFT-PAPER HONEYCOMB, POLYSTYRENE, POLYURETHANE, C. INSTALL COMPONENTS TO DRAIN WATER PASSING JOINTS, CONDENSATION OCCURRING WITHIN FRAMING MEMBERS, AND A R C H I T E C T U R A L G R O UP I N C 9 C. WATER: ASTM C 94/C 94M[ AND POTABLE]. MINERAL -BOARD, OR VERTICAL STEEL -STIFFENER CORE THAT PRODUCES DOORS COMPLYING WITH ANSI A250.8. MOISTURE MIGRATING WITHIN THE SYSTEM TO EXTERIOR. J. Steven Carrillo 11231 Gold Express Dr. 1 D. AIR -ENTRAINING ADMIXTURE: ASTM C 260. A. PERFORM WORK IN ACCORDANCE WITH AWI CUSTOM GRADE QUALITY. 2. VERTICAL EDGES FOR SINGLE -ACTING DOORS: BBEVElFO EDGE. D. SET CONTINUOUS SILL MEMBERS AND FLASHING IN FULL SEALANT BED AS SPECIFIED IN DIVISION 7 SECTION "JOINT A.I.A. C11.222 Suite 103 Gold River, CA 95670 m 2.4 VAPOR RETARDERS A. MATCH EXISTING. B. WOODWORK/MILLWORK MANUFACTURERS SHALL BE CERTIFIED BY THE AWI QUALITY CERTIFICATION PROGRAM AS COMPETENT A. BEVELED EDGE: 1/8 INCH IN 2 INCHES. 3. TOP AND BOTTOM EDGES: CLOSED WITH FLUSH OR INVERTED 0.042-INCH- THICK END CLOSURES OR CHANNELS OF SEALANTS' AND TO PRODUCE WEATHERTIGHT INSTALLATION. E. INSTALL COMPONENTS PLUMB AND TRUE IN ALIGNMENT WITH ESTABLISHED LINES AND GRADES, WITHOUT WARP OR RACK. 916 266-6000 FAX 266-6006 THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY 2.5 CURING MATERIALS TO PERFORM THE WORK SPECIFIED. SAME MATERIAL AS FACE SHEETS. F. INSTALL GLAZING AS SPECIFIED IN DIVISION 8 SECTION "GLAZING RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN A. CLEAR, WATERBORNE, MEMBRANE -FORMING CURING COMPOUND: ASTM C 309, TYPE 1, CLASS B, NONDISSIPATING[, 1.4 DELIVERY, STORAGE AND HANDLING B. EXTERIOR DOORS: FACE SHEETS FABRICATED FROM METALLIC -COATED STEEL SHEET. PROVIDE DOORS COMPLYING WITH REQUIREMENTS INDICATED BELOW BY REFERENCING ANSI A250.8 FOR LEVEL AND MODEL AND ANSI A250.4 FOR G. ENTRANCES: INSTALL TO PRODUCE SMOOTH OPERATION AND TIGHT FIT AT CONTACT POINTS. THESE PLANS. IDEAS AND DESIGNS OR M ARE NOT T BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY ARE CERTIFIED BY CURING COMPOUND MANUFACTURER TO NOT INTERFERE WITH BONDING OF FLOOR COVERING]. PHYSICAL -ENDURANCE LEVEL: 1. EXTERIOR ENTRANCES: INSTALL TO PRODUCE TIGHT FIT AT WEATHER STRIPPING AND WEATHERTIGHT CLOSURE. TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE 2.6 CONCRETE MIXTURES 2. FIELD -INSTALLED HARDWARE: INSTALL SURFACE -MOUNTED HARDWARE ACCORDING TO HARDWARE MANUFACTURERS' EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE DRAWING IS NOT A. PREPARE DESIGN MIXTURES FOR EACH TYPE AND STRENGTH OF CONCRETE, PROPORTIONED ON THE BASIS OF LABORATORY A. PROTECT UNITS FROM MOISTURE DAMAGE ACCORDING TO AWI QUALITY STANDARDS, SECTION 1700 - INSTALLATION. WRITTEN INSTRUCTIONS USING CONCEALED FASTENERS TO GREATEST EXTENT POSSIBLE. FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT. Drawing Title 9 TRIAL MIXTURE OR FIELD TEST DATA, OR BOTH, ACCORDING TO ACI 301. B. PROTECT CABINETRY DURING TRANSIT, DELIVERY, STORAGE AND HANDLING TO PREVENT DAMAGE, SOILING AND 1. LEVEL 3 AND PHYSICAL PERFORMANCE LEVEL A (EXTRA HEAVY DUTY), MODEL 2 (SEAMLESS). H. INSTALL PERIMETER JOINT SEALANTS A5 SPECIFIED IN DIVISION 7 SECTION "JOINT SEALANTS AND TO PRODUCE B. PROPORTION NORMAL -WEIGHT CONCRETE MIXTURE AS FOLLOWS: DETERIORATION. 1.5 COORDINATION C. INTERIOR DOORS: FACE SHEETS FABRICATED FROM COLD -ROLLED STEEL SHEET, UNLESS OTHERWISE INDICATED TO COMPLY WEATHERTIGHT INSTALLATION. 1. MINIMUM COMPRESSIVE STRENGTH 3500 AT 28 DAYS. A. COORDINATE WORK WITH GENERAL CONTRACTOR, APPLICABLE MECHANICAL TRADE, ELECTRICAL TRADE AND ROUGH -IN. WITH EXTERIOR DOOR REQUIREMENTS. PROVIDE DOORS COMPLYING WITH REQUIREMENTS INDICATED BELOW BY REFERENCING ANSI A250.8 FOR LEVEL AND MODEL AND ANSI A250.4 FOR PHYSICAL -ENDURANCE LEVEL: SECTION 08712 - DOOR HARDWARE SPECIFIC TIONS 2.7 FABRICATING REINFORCEMENT "MANUAL B. COORDINATE SIZES AND LOCATIONS OF FRAMING, BLOCKING, FURRING, REINFORCEMENTS, AND OTHER RELATED UNITS 1.1 GENERAL A. FABRICATE STEEL REINFORCEMENT ACCORDING TO CRSI'S OF STANDARD PRACTICE." OF WORK SPECIFIED IN OTHER SECTIONS TO ENSURE THAT INTERIOR ARCHITECTURAL WOODWORK CAN BE SUPPORTED AND 1. LEVEL 2 AND PHYSICAL PERFORMANCE LEVEL B (HEAVY DUTY), 2 (SEAMLESS). A. PROVIDE FINISH HARDWARE THROUGHOUT THE WORK AS NEEDED FOR A COMPLETE INSTALLATION AND AS SPECIFIED HEREIN. 2.8 CONCRETE MIXING INSTALLED AS INDICATED. 2.2 STANDARD STEEL FRAMES B. FIRE RATED OPENINGS: COMPLY WITH NFPA STANDARD NO. 80 AND LOCAL CODES FOR INSTALLATION OF HARDWARE IN Seal e -11 Drawn Checked A. READY -MIXED CONCRETE: MEASURE, BATCH, MIX, AND DELIVER CONCRETE ACCORDING TO ASTM C 94/C 94M[ AND ASTM C PART 2 - PRODUCTS A. GENERAL: COMPLY WITH ANSI A250.8 AND WITH DETAILS INDICATED FOR TYPE AND PROFILE. FIRE -RATED ASSEMBLIES, PROVIDE ONLY HARDWARE, WHICH HAS BEEN TESTED AND LISTED BY UL OR FM IN COMPLIANCE 1116], AND FURNISH BATCH TICKET INFORMATION. B. EXTERIOR FRAMES: FABRICATED FROM METALLIC -COATED STEEL SHEET. WITH REQUIREMENTS OF DOOR AND DOOR FRAME LABELS. ARC�` TCB NSH 2.9 CONCRETE PLACEMENT A. BEFORE PLACING CONCRETE, VERIFY THAT INSTALLATION OF FORMWORK, REINFORCEMENT, AND PART 3 - EXECUTION 1. FRAMES FOR LEVEL 3 STEEL DOORS: 0.053-THICK STEEL SHEET, UNLESS OTHERWISE INDICATED]. C. IF EXISTING, REMOVE EXISTING DEADBOLTS WITH KEYED CYLINDER LOCKS INSIDE. REPLACE WITH NEW HARDWARE PER ' 7f CA Project No. EMBEDDED ITEMS IS COMPLETE C. INTERIOR FRAMES: FABRICATED FROM COLD -ROLLED STEEL SHEET, UNLESS OTHERWISE INDICATED TO COMPLY WITH SCHEDULE. p� a AND THAT REQUIRED INSPECTIONS HAVE BEEN PERFORMED. 3.1 EXAMINATION EXTERIOR FRAME REQUIREMENTS. D. KEYING: LOCK SETS SHALL BE KEYED TO OWNERS SYSTEM AND SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. �4 � � 04139.66 B. DEPOSIT CONCRETE CONTINUOUSLY IN ONE LAYER OR IN HORIZONTAL LAYERS OF SUCH THICKNESS THAT NO NEW CONCRETE 1. FRAMES FOR LEVEL 2 STEEL DOORS: 0.053-INCH THICK STEEL SHEET, UNLESS OTHERWISE INDICATED]. FURNISH 2 HEYS PER LOCK WITH A MAXIMUM OF 8 KEYS PER KEYED ALIKE SET. f < . .A Date WILL BE PLACED ON CONCRETE THAT HAS HARDENED ENOUGH TO CAUSE SEAMS OR PLANES OF WEAKNESS. IF A SECTION A. VERIFY ADEQUACY OF BACKING AND SUPPORT FRAMING. D. SUPPORTS AND ANCHORS: FABRICATED FROM ELECTROLYTIC ZINC -COATED OR METALLIC -COATED STEEL SHEET. E. ADJUST AND CHECK OPERATION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND CANNOT BE PLACED CONTINUOUSLY, PROVIDE CONSTRUCTION JOINTS AS INDICATED. DEPOSIT CONCRETE TO AVOID B. VERIFY MECHANICAL, ELECTRICAL, AND BUILDING ITEMS AFFECTING WORK OF THIS SECTION ARE PLACED AND READY TO 2.3 FABRICATION SMOOTHLY. 1-7-05 SEGREGATION. 1. CONSOLIDATE PLACED CONCRETE WITH MECHANICAL VIBRATING EQUIPMENT ACCORDING TO ACI 301. RECEIVE THIS WORK. A. GENERAL: FABRICATE STANDARD STEEL DOORS AND FRAMES TO BE RIGID AND FREE OF DEFECTS, WARP, OR BUCKLE. D SIZES AND PROFILES, WITH MI ACCURATELY FORM METAL TO REQUIRED NIMUM RADIUS FOR THICKNESS OF METAL. WHERE 1.2 SUBMITTALS A. SUBMIT HARDWARE AND KEYING SCHEDULES INDICATING EACH OPENING WITH DOOR NUMBER, DOOR AND FRAME SIZE, DOOR ' - J' No. CI p,�22 �Q y REN a 105 � Scale FULL C. COLD -WEATHER PLACEMENT: COMPLY WITH ACI 306.1. AND FRAME MATERIAL, HAND OF DOOR, DEGREE OF OPENING, FIRE LABEL IDENTIFICATION AND OTHER SPECIAL DETAILS. 04- D. HOT -WEATHER PLACEMENT: COMPLY WITH ACI 301. PRACTICAL, FIT AND ASSEMBLE UNITS MANUFACTURER'S PLANT. T ENSURE PROPER ASSEMBLY AT PROJECT SITE, CLEARLY IDENTIFY WORK THAT CANNOT BE PERMANENTLY FACTORY ASSEMBLED B. PROVIDE TEMPLATES OR PHYSICAL SAMPLES OF THE ITEMS TO PERTINENT MANUFACTURERS OF DOORS AND FRAMES IN A OF A��F Drawing No. BEFORE SHIPMENT. TIMELY MANNER TO ASSURE ORDERLY PROGRESS OF THE WORK. G -2 1 2 3 4 5 6 7 8 9 10 I 11 1 12 / ,�� 1 2 3 4 5 6 7 8 9 10 111 12 1.3 ACCEPTABLE MANUFACTURERS: FOR EACH OF THE REQUIRED ITEMS OF FINISH HARDWARE, PROVIDE FORM ONE OF THE PART 3 - EXECUTION SPECIFIED MANUFACTURERS LISTED HEREIN. 3.1 INSTALLATION G. SCHEDULING PAINTING: APPLY FIRST COAT TO SURFACES THAT HAVE BEEN CLEANED, PRETREATED, OR OTHERWISE PREPARED A ARCHITECTURAL ID INSIDE DIAMETER VCT VINYL BUTTS PBB A. GENERAL: INSTALL ACOUSTICAL PANEL CEILINGS TO COMPLY WITH [ASTM C 636] [UBC STANDARD 25-21 AND SEISMIC FOR PAINTING AS SOON AS PRACTICABLE AFTER PREPARATION AND BEFORE SUBSEQUENT SURFACE DETERIORATION. AB ANCHOR BOLT IN INCH COMPOSITION TILE Sprm LOCKSETS PDQ INDUSTRIES, INC., ADAMS RITE REQUIREMENTS INDICATED, PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND CISCA'S "CEILING SYSTEMS HANDBOOK." 1. OMIT PRIMER OVER METAL SURFACES THAT HAVE BEEN SHOP PRIMED AND TOUCHUP PAINTED. AC ACOUSTICAL CEILING INSUL INSULATION VERT VERTICAL DOOR CLOSERS DORMA B. MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL PANELS TO BALANCE BORDER WIDTHS AT OPPOSITE 2. IF UNDERCOATS, STAINS, OR OTHER CONDITIONS SHOW THROUGH FINAL COAT OF PAINT, APPLY ADDITIONAL COATS UNTIL AFF ABOVE FINISH FLOOR INT INTERIOR VEST VESTIBULE AW ACOUSTICAL WALLCOVERING EXIT DEVICES DOOR CONTROLS INTERNATIONAL EDGES OF EACH CEILING. AVOID USING LESS -THAN -HALF -WIDTH TILES AT BORDERS. PAINT FILM IS OF UNIFORM FINISH, COLOR, AND APPEARANCE. ACOUS ACOUSTICAL JAN JANITOR VIF VERIFY IN FIELD - MISCELLANEOUS DOOR CONTROLS INTERNATIONAL PLATES AND PULLS SIGNATURE BRASS C. SUSPEND CEILING HANGERS FROM BUILDING'S STRUCTURAL MEMBERS, PLUMB AND FREE FROM CONTACT WITH INSULATION OR OTHER OBJECTS WITHIN CEILING PLENUM. SPLAY HANGERS ONLY WHERE REQUIRED[ AND, IF PERMITTED WITH H. APPLICATION PROCEDURES: APPLY PAINTS AND COATINGS BY BRUSH, ROLLER, SPRAY, OR OTHER APPLICATORS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. ADJ ADJACENT, ADJUSTABLE JST JOIST WALLCOVERING AL, ALUM ALUMINUM JT JOINT VWC VINYL 1446 S A N T A A N CA STOPS SIGNATURE BRASS THRESHOLDS & SEALS REESE FIRE -RESISTANCE -RATED CEILINGS,] TO MISS OBSTRUCTIONS; OFFSET RESULTING HORIZONTAL FORCES BY BRACING, COUNTERSPLAYING, OR OTHER EQUALLY EFFECTIVE MEANS. WHERE WIDTH I. MINIMUM COATING THICKNESS: APPLY PAINT MATERIALS NO THINNER THAN MANUFACTURER'S RECOMMENDED SPREADING RATE. PROVIDE TOTAL DRY FILM THICKNESS OF THE ENTIRE SYSTEM AS RECOMMENDED BY MANUFACTURER. ALT ALTERNATE W WEST AP ACCESS PANEL KIT KITCHEN W/ WITH ' PLAZA SOUTH COAST OF DUCTS AND OTHER CONSTRUCTION WITHIN KP KICK PLATE LOCK GUARD SIGNATURE BRASS CEILING PLENUM PRODUCES HANGER SPACINGS THAT INTERFERE WITH LOCATION OF HANGERS, USE TRAPEZES OR J. PRIME COATS: BEFORE APPLYING FINISH COATS, APPLY A PRIME COAT, AS RECOMMENDED BY MANUFACTURER, TO MATERIAL APPROX APPROXIMATE WC WALL COVERING, ARCH ARCHITECTURAL 1.4 HARDWARE SCHEDULE EQUIVALENT DEVICES. THAT IS REQUIRED TO BE PAINTED OR FINISHED AND THAT HAS NOT BEEN PRIME COATED BY OTHERS. RECOAT PRIMED LAM LAMINATE, LAMINATED WATER CLOSET AW AWNING FABRIC WD 3611 SOUTH BRISTOL ST. A. REFER TO DOOR SCHEDULE FOR ADDITIONAL INFORMATION ABOUT HARDWARE, SPECIAL KEYING AND LOCKING ARRANGEMENT. 1. DO NOT SUPPORT CEILINGS DIRECTLY FROM PERMANENT METAL FORMS OR FLOOR DECK; ANCHOR INTO CONCRETE AND SEALED SURFACES WHERE EVIDENCE OF SUCTION SPOTS OR UNSEALED AREAS IN FIRST COAT APPEARS, TO ENSURE A LAV LAVATORY WOOD WDO WINDOW SLABS. FINISH COAT WITH NO BURN -THROUGH OR OTHER DEFECTS DUE TO INSUFFICIENT SEALING. B BASE LT LIGHT WF WOOD FLOOR SUITE B 2. DO NOT ATTACH HANGERS TO STEEL DECK TABS[ OR TO STEEL ROOF DECK]. 3.2 CLEANING AND PROTECTING BD BOARD M MECHANICAL WM WALK -OFF MAT SANTA ANA, CA 92704 SECTION 08800 - GLAZING GENERAL, 1 - GENE A. AT THE END OF EACH WORKDAY, REMOVE EMPTY CANS, RAGS, RUBBISH, AND OTHER DISCARDED PAINT MATERIALS FROM PROJECT SITE. BG BUMPER GUARD M MOLDING W/O WITHOUT BLDG BUILDING MACH MACHINE WPP WATERPROOF PROJECT TEAM 1.1 SUMMARY B. PROTECT WORK OF OTHER TRADES, WHETHER BEING PAINTED OR NOT, AGAINST DAMAGE FROM PAINTING, CORRECT DAMAGE BLK BLOCK MATL MATERIAL WR WATER RESISTANT BLKG BLOCKING 1. THIS SECTION INCLUDES GLASS AND GLAZING AS SHOWN ON THE DRAWINGS, AS SPECIFIED HEREIN, AND AS SECTION 09650 - RESILIENT FLOORING BY CLEANING, REPAIRING OR REPLACING, AND REPAINTING, AS APPROVED BY ARCHITECT. MAX MAXIMUM WT WEIGHT BM BEAM NEEDED TO MEET THE REQUIREMENTS OF THE CONSTRUCTION. 1.1 GENERAL C. PROVIDE "WET PAINT" SIGNS TO PROTECT NEWLY PAINTED FINISHES. AFTER COMPLETING PAINTING OPERATIONS, REMOVE MECH MECHANICAL BO BOTTOM OF MEMB MEMBRANE 1.2 PERFORMANCE REQUIREMENTS A. PROVIDE RESILIENT FLOORING WHERE INDICATED IN THE DRAWINGS AS REQUIRED HEREIN, AND AS NECESSARY FORA TEMPORARY PROTECTIVE WRAPPINGS PROVIDED BY OTHERS TO PROTECT THEIR WORK. BOT BOTTOM MFR MANUFACTURER OWNER'S PROJECT MANAGER TRAMMELL CROW A. GENERAL: PROVIDE GLAZING SYSTEMS CAPABLE OF WITHSTANDING NORMAL THERMAL MOVEMENT AND WIND AND IMPACT COMPLETE AND PROPER INSTALLATION. THE WORK INCLUDES CALCULATION OF MATERIAL QUANTITY REQUIRED, LEVELING AND 1. AFTER WORK OF OTHER TRADES IS COMPLETE, TOUCH UP AND RESTORE DAMAGED OR DEFACED PAINTED SURFACES. MH MANHOLE LOADS WHERE APPLICABLE WITHOUT FAILURE, INCLUDING LOSS OR GLASS BREAKAGE ATTRIBUTABLE TO THE ( ) PATCHING OF CONCRETE FLOORS, INSTALLATION OF RESILIENT FLOORING AND ACCESSORIES. COMPLY WITH PROCEDURES SPECIFIED IN PDCA P1. CAB CABINET MIN MINIMUM FOLLOWING: DEFECTIVE MANUFACTURE, FABRICATION, AND INSTALLATION; FAILURE OF SEALANTS OR GASKETS TO REMAIN 1.2 SUBMITTALS 3.3 INTERIOR PAINT SCHEDULE CEM CEMENT CER CERAMIC MIR MIRROR SPRINT PCS PROJECT MANAGER = WATERTIGHT AND AIRTIGHT; DETERIORATION OF GLAZING MATERIALS; OR OTHER DEFECTS IN CONSTRUCTION. A. PRODUCT DATA: FOR EACH PRODUCT INDICATED. A. WOOD: CIF CONCRETE FINISH MISC MISCELLANEOUS 6100 SPRINT PARKWAY 1. GLAZING STANDARDS: COMPLY WITH RECOMMENDATIONS OF FLAT GLASS MARKETING ASSOCIATION (FGMA) PART 2 - PRODUCTS 1ST COAT PRIMER/FILLER AS REQUIRED CG CORNER GUARD MO MASONRY OPENING "GLAZING MANUAL AND SEALANT MANUAL EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE INDICATED. 2.1 MATERIALS 2ND COAT INTERIOR SEMI -GLOSS ENAMEL CJ CONTROL JOINT M/R MOISTURE RESISTANT Mailstop: KSOPHKO410-4A554 REFER TO THOSE PUBLICATIONS FOR DEFINITIONS OF GLASS AND GLAZING TERMS NOT OTHER WISE DEFINED IN A. VINYL COMPOSITION TILE: 12X12X1/8 VCT OR 36"X36" VINYL FLOORING PER FINISH SCHEDULE. B. METAL: CL CLOSET MTTD MOUNTED OVERLAND PARK, KS 66251 THIS SECTION OR OTHER REFERENCED STANDARDS. B. TRANSITION AND EDGE STRIPS; RUBBER, THICKNESS TO MATCH ADJACENT TILE, TAPERED, OR BULLNOSE EDGE. COLOR PER 1ST COAT PRIMER CLKG CAULKING MTG MEETING, MOUNTINGMTL METAL PHONE; (913) 315-5110 2. SAFETY GLAZING STANDARDS: WHERE SAFETY GLASS IS INDICATED OR REQUIRED BY AUTHORITIES HAVING FINISH SCHEDULE. 2ND COAT INTERIOR SEMI -GLOSS ENAMEL MTL MULLION CONTACT: RON GERARD ron.d.gerard®mail.sprint.com JURISDICTION, PROVIDE TYPE OF PRODUCTS INDICATE WHICH COMPLY WITH ANSI Z97.1 AND TESTING C. LEVELING COMPOUND: ARDEX SD-1 3RD COAT INTERIOR SEMI -GLOSS ENAMEL CCLG LR CEILING REQUIREMENTS OF 16 CFR PART 1201 FOR CATEGORY II MATERIALS. D. ADHESIVE: WATER RESISTANT, NON -STAINING AS RECOMMENDED BY VCT MANUF. C. CONCRETE: CMU CONCRETE MASONRY UNIT N NORTH 3. GLASS PRODUCTS: TEMPERED GLASS - PROVIDE PRIME GLASS OF COLOR AND TYPE TO MATCH EXISTING, WHICH HAS BEEN HEAT TREATED TO STRENGTHEN GLASS IN B ENDING TO NOT LESS THAN 4.5 TIMES ANNEALED 2.2 INSTALLATION A. IF FLOOR LEVELING OR PREPARATION IS REQUIRED TO MAKE FLOOR SURFACE READY FOR FINISH WORK, CONTRACTOR SHALL 1ST COAT CONCRETE SEALER D. WOOD DOORS: COL COLUMN NED NEOPRENE CONIC CONCRETE NIC NOT IN CONTRACT COND CONDITION ARCHITECT CARRILLO ARCHITECTURAL GROUP, INC. STRENGTH. PREPARE FLOOR ARE PER MANUFACTURERS REQUIREMENTS. 1ST COAT PRIMER FILLER AS REQUIRED / NO NUMBER CONSTR CONSTRUCTION 4. GLAZING SEALANT AND COMPONENTS: PROVIDE COLOR OF EXPOSED SEALANT AND COMPOUND, TAPES AND B. INSTALL WALL TO WALL AND TO FIXED CABINETS AND UNDER FREESTANDING EQUIPMENT. 2ND COAT INTERIOR SEMI -GLOSS ENAMEL CONT CONTINUOUS NTOS NOTTO11231 GOLD EXPRESS DR., SUITE 103 OTHER MATERIAL INDICATED OR IF NOT OTHERWISE INDICATED TO MATCH EXISTING. PROVIDE SETTING BLOCKS, C. LAY OUT SQUARE, PARALLEL WITH STRAIGHT UNBROKEN JOINT LINES. FIT TIGHTLY AND ACCURATELY TO VERTICAL SURFACE, CONTR CONTRACTOR SHIMS, COMPRESSION SEALS, FELT AND NEOPRENE OR VINYL GLAZING CHANNELS AS REQUIRED FOR FIRST FLOOR PLATES, THRESHOLDS, EDGING STRIPS WITH CLEAR CUTS. SECTION 100D0 - MISCELLANEOUS SPECIALTIES CORR CORRIDOR OA OVERALL GOLD RIVER, CA 95670 CLASS WORKMAN LIKE JOB. 2.3 CLEANING AND FINISHING 1.1 SIGNS CPT, C CARPET OBS OBSCURE PHONE: (916) 266-6000 5. INSTALLATION: A. CLEAN ALL RESILIENT FLOORING THOROUGHLY AND APPLY WAX OF FINISHING MATERIALS IN ACCORD WITH MANUFACTURERS A. CONSTRUCTION MANAGER SHALL PROVIDE EXTERNAL SIGNAGE AND INSTALLATION. SIGN SUBCONTRACTOR IS RESPONSIBLE CT CERAMIC TILE OC ON CENTER FAX: 916 266-6006 ( ) A. CLEAN GLAZING CHANNEL AND OTHER FRAMING MEMBERS TO RECEIVE GLASS IMMEDIATELY BEFORE RECOMMENDATIONS. B. POLISH THOROUGHLY. DELAY CLEANING AND FINISHING UNTIL JUST PRIOR FOR ALL PERMITS AND ZONING ISSUES AS REQUIRED. CONTRACTOR TO COORDINATE LOCATION OF POWER FOR SIGNAGE. CTR CENTER OD OUTSIDE DIAMETER CENTER LINE OFF OFFICE CONTACT: NATE HENINGER nateheninger@carrilloag.com GLAZING. REMOVE COATINGS, WHICH ARE NOT FIRMLY BONDED TO SUBSTRATE. REMOVE LACQUER FROM TO DATE OF SUBSTANTIAL COMPLETION. B. INTERIOR ACCESSIBILITY SIGNS PER DRAWINGS. OPNG OPENING METAL SURFACES WHERE ELASTOMERIC SEALANTS ARE USED. DCD DESIGN CONTROL DRAWINGS OPP OPPOSITE B. COMPLY WITH FGMA GLAZING MANUAL AND MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. USE SECTION 10801 - TOILET AND BATH ACCESSORIES DET, DTL DETAIL OSB ORIENTED STRAND MEP ENGINEERS MANUFACTURER'S RECOMMENDED SPACERS, BLOCKS, PRIMERS, SEALERS, GASKETS AND ACCESSORIES. SECTION 09653 - RESILIENT BASE 1.1 MANUFACTURERS DIA DIAMETER BOARD HENDERSON ENGINEERS C. PROTECT GLASS FROM BREAKAGE IMMEDIATELY UPON INSTALLATION BY USE OF CROSSED STREAMERS 1.1 GENERAL A. BOBRICK OR APPROVED EQUAL. TYPE 304 STAINLESS STEEL, TYPICAL. DIFF DIFFUSER ATTACHED TO FRAMING AND HELD AWAY FROM GLASS. DO NOT APPLY MARKERS TO SURFACES OF GLASS. A. PROVIDE RESILIENT BASE WHERE INDICATED IN THE DRAWINGS, AS REQUIRED HEREIN, AND AS NECESSARY FOR A COMPLETE B. WALL MOUNTED PAPER TOWEL DISPENSER SHALL BE BOBRICK MODEL NO. 9-262. DIM DIMENSION P PAINT DISP DISPENSER P PLUMBING 8325 LENEXA DRIVE, SUITE 400 REMOVE NON -PERMANENT LABELS AND CLEAN SURFACES. CURE SEALANTS FOR HIGH EARLY STRENGTH AND PROPER INSTALLATION. THE WORK INCLUDES CALCULATION OF MATERIAL QUANTITY REQUIRED. C. SOAP DISPENSER SHALL BE BOBRICK MODEL NO. B-111. DIN DOWN PL PLATEDO AND DURABILITY. B. REPLACEMENT MATERIALS: AFTER COMPLETION OF WORK, DELIVER NOT LESS THAN 10 FEET OF EXTRA STOCK TO TENANT. D. NAPKIN DISPOSAL SHALL BE BOBRICK MODEL NO. B-270. DOOR OPENING P. LAM, PL- PLASTIC LAMINATE LENEXA, KS 66214 D. WASH AND POLISH GLASS ON BOTH FACES NOT MORE THAN 4 DAYS PRIOR TO DATE SCHEDULED FOR INSPECTIONS INTENDED TO ESTABLISH DATE OF SUBSTANTIAL COMPLETION. COMPLY WITH GLASS PRODUCT EXTRAS SHALL BE FROM THE SAME BATCH AS THOSE INSTALLED. 1.2 SUBMITTALS E. TOILET TISSUE DISPENSER SHALL BE BOBRICK MODEL N0, B-686. F. GRAB BARS SHALL BE BOBRICK MODEL NO. B-6206 36 AND 48 INCH. ALL GRAB BARS SHALL BE SECURELY ANCHORED DR DOOR PLAS PLASTER DWG(S) DRAWING, DRAWINGS PLYWD PLYWOOD PHONE: (913) 307-5464 FAX: (913) 307-5400 MANUFACTURERS RECOMMENDATIONS FOR FINAL CLEANING.. A. PRODUCT DATA: FOR EACH PRODUCT INDICATED. WITH THE MANUFACTURERS RECOMMENDED MOUNTING KIT FOR APPROPRIATE TYPE OF CONSTRUCTION AND WILL SUPPORT DWR DRAWER PMS PANTONE MATCHING CONTACT: TREVOR JONES trevor. ones@hendersonen ineers.com 1 9 PART 2 - PRODUCTS LOADS IN EXCESS OF 900 POUNDS. SYSTEM SECTION 09260 -GYPSUM BOARD ASSEMBLIES 2.1 MATERIALS G. MIRRORS SHALL BE BOBRICK MODEL NO. B-293 SERIES TILT MIRROR 1830 OR APPROVED EQUAL, E EAST PNL PANEL, PANELBOARD EA EACH PART 1 - GENERAL A. RESILIENT BASE PER FINISH SCHEDULE. H. SEAT COVER DISPENSER SHALL BE BOBRICK MODEL N0. B-221. PP PREFINISHED PANELS EIFS EXTERIOR INSULATION LANDLORD 1.1 SUMMARY B. ADHESIVE: WATER RESISTANT, NON -STAINING AS RECOMMENDED BY MANUF. I. COAT HOOK SHALL BE BOBRICK MODEL NO. B-682. FINISH SYSTEM PR PAIR PROP PROJECT INVESTCORP / ORANGE BRISTOL, LP A THIS SECTION INCLUDES THE FOLLOWING: 2.2 INSTALLATION J. MOP AND BROOM HOLDER SHALL BE BOBRICK MODEL NO. B-223. EJ EXPANSION JOINT PROP PROPERTY �- 1. INTERIOR GYPSUM WALLBOARD. 2. TILE BACKING PANELS. A. INSTALL AROUND CABINETS AND OTHER STANDING EQUIPMENT. B. SET STRAIGHT AND EVEN, JOINTS CLOSELY FITTED AND FLUSH, TOP AND BOTTOM, EDGES IN FIRM, FULL CONTACT WITH 1.2 INSTALLATION A. INSTALL ACCESSORIES USING FASTENERS APPROPRIATE TO SUBSTRATE INDICATED AND RECOMMENDED BY UNIT EL, ELEV ELEVATION PT PRESSURE TREATED E ELEC ELECTRIC, ELECTRICAL � PT POINT 280 PARK AVE, 36TH FLOOR 3. NON -LOAD -BEARING STEEL FRAMING. FLOOR AND WALL, OR TREADS AND ENTIRE BACKSIDE BONDED TO SUBSTRATE. PREVENT STAINING OF ADJACENT SURFACES. MANUFACTURER. INSTALL UNITS LEVEL, PLUMB, AND FIRMLY ANCHORED IN LOCATIONS AND AT HEIGHTS INDICATED. ELEV ELEVATOR PTN PARTITION NEW YORK, NY 10017 1.2 QUALITY ASSURANCE 2.3 CLEANING AND FINISHING: B. ADJUST ACCESSORIES FOR UNENCUMBERED, SMOOTH OPERATION AND VERIFY THAT MECHANISMS FUNCTION PROPERLY. EMER EMERGENCY PWR POWER PHONE: (212) 577-1414 A. FIRE -TEST -RESPONSE CHARACTERISTICS: FOR GYPSUM BOARD ASSEMBLIES WITH FIRE -RESISTANCE RATINGS, PROVIDE A. CLEAN ALL RESILIENT BASE THOROUGHLY IN ACCORD WITH MANUFACTURES RECOMMENDATIONS. REPLACE DAMAGED OR DEFECTIVE ITEMS. REMOVE TEMPORARY LABELS AND PROTECTIVE COATINGS. ENCL ENCLOSURE EQUIP EQUIPMENT CONTACT: HEATHER MUTTERPERL MATERIALS AND CONSTRUCTION IDENTICAL TO THOSE TESTED IN ASSEMBLY INDICATED ACCORDING TO ASTM E 119 BY AN B. REMOVE STAINS AND EXCESS ADHESIVE FROM BASE AND ADJACENT SURFACES WITHOUT INJURY TO SURFACES. SECTION 1100 - EQUIPMENT EWC ELECTRIC WATER COOLER QT QUARRY TILE QTY QUANTITY INDEPENDENT TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. C. REMOVE ALL SCRAPS AND RUBBISH. 1.3 PROVIDE THE FOLLOWING EQUIPMENT WHERE NOTED ON THE DRAWINGS AND SPECIFIED HEREIN. PROVIDE ALLOWANCES AS EXH EXHAUST PART 2 - PRODUCTS INDICATED BELOW. EXIST EXISTING R RISER 2.1 MANUFACTURERS A. IN OTHER PART 2 ARTICLES WHERE SUBPARAGRAPH TITLES BELOW INTRODUCE LISTS, THE FOLLOWING REQUIREMENTS APPLY FOR PRODUCT SELECTION: SECTION 09912 -PAINTING PART 1 - GENERAL 1.1 SUMMARY A. REFRIGERATOR: 6 TO 8 CUBIC FEET, $300 ALLOWANCE. B. MICROWAVE: $100 ALLOWANCE. EXP EXPANSION, EXPOSED RAD, R RADIUS EXT EXTERIOR RD ROOF DRAIN F FIXTURE REFL REFLECTED 1. AVAILABLE PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PRODUCTS THAT MAY BE INCORPORATED INTO A. THIS SECTION INCLUDES SURFACE PREPARATION AND FIELD PAINTING OF EXPOSED ITEMS AND SURFACES. FA FIRE ALARM REINF REINFORCED THE WORK INCLUDE, BUT ARE NOT LIMITED TO, THE PRODUCTS SPECIFIED. 1.2 PROJECT CONDITIONS SECTION 1200 - FURNISHINGS FD FLOOR DRAIN REQ, REQD REQUIRED 2.2 STEEL FRAMING A. STORE MATERIALS NOT IN USE IN TIGHTLY COVERED CONTAINERS IN A WELL -VENTILATED AREA AT A MINIMUM AMBIENT 1.4 GENERAL FDN FOUNDATION RESIL RESILIENT RF RESILIENT FLOORING A. STEEL FRAMING, GENERAL: COMPLY WITH ASTM C 754 FOR CONDITIONS INDICATED. TEMPERATURE OF 45 DEG F. MAINTAIN STORAGE CONTAINERS IN A CLEAN CONDITION, FREE OF FOREIGN MATERIALS AND A. CONTRACTOR SHALL COORDINATE THE DELIVERY AND INSTALLATION OF FIXTURES AND OTHER ITEMS SUPPLIED, AND INSTALLED FE FIRE EXTINGUISHER RM ROOM 1. STEEL SHEET COMPONENTS: METAL COMPLYING WITH ASTM C 645 REQUIREMENTS. RESIDUE. BY THE TENANTS VENDORS. FEC FIRE EXTINGUISHER CABINET RO ROUGH OPENING B. SUSPENDED CEILING AND SOFFIT FRAMING: B. APPLY WATERBORNE PAINTS ONLY WHEN TEMPERATURES OF SURFACES TO BE PAINTED AND SURROUNDING AIR ARE BETWEEN B. CONTRACTOR SHALL ASSEMBLE AND INSTALL FURNISHINGS PROVIDED BY SPRINT PCS, INCLUDING FURNITURE, SHELVING FIN FINISH RWL RAIN WATER LEADER w 1. TIE WIRE: ASTM A 641/A 641M, CLASS 1 ZINC COATING, SOFT TEMPER, 0.0625-INCH- DIAMETER WIRE, OR DOUBLE 50 AND 90 DEC. SYSTEM, TELEVISIONS, DVDS, AND TECH BENCHES. FIX, FIXT FIXTURE FL, FLR FLOOR S SOUTH STRAND OF 0.0475-INCH- DIAMETER WIRE. C. APPLY SOLVENT -THINNED PAINTS ONLY WHEN TEMPERATURES OF SURFACES TO BE PAINTED AND SURROUNDING AIR ARE SECTION 12484 -FLOOR MAT do FRAME FLASH FLASHING SC SOLID CORE 2. HANGER ATTACHMENTS TO CONCRETE: BETWEEN 45 AND 95 DEG F. 1.1 MANUFACTURE FLUOR FLUORESCENT SCHED SCHEDULE A. POWDER -ACTUATED FASTENERS: SUITABLE FOR APPLICATION INDICATED, FABRICATED FROM CORROSION -RESISTANT 1.3 EXTRA MATERIALS A. CONSTRUCTION SPECIALTIES, INC. FOC FACE OF CONCRETE SD SOAP DISPENSER MATERIALS, WITH CLIPS OR OTHER DEVICES FOR ATTACHING HANGERS OF TYPE INDICATED, AND CAPABLE OF A. FURNISH EXTRA PAINT MATERIALS FROM THE SAME PRODUCTION RUN AS THE MATERIALS APPLIED AND IN THE QUANTITIES FOF FACE OF FINISH SECT SECTION SUSTAINING, WITHOUT FAILURE, A LOAD EQUAL TO [10] TEN TIMES THAT IMPOSED BY CONSTRUCTION AS DETERMINED DESCRIBED BELOW. PACKAGE WITH PROTECTIVE COVERING FOR STORAGE AND IDENTIFY WITH LABELS DESCRIBING CONTENTS. B. PEDIMENT AA, ALUMINUM LEVEL BASE RECESSED FRAME, CLEAR ANODIZED. EXTERIOR CARPET #7323 CASTLE GRAY. 1" BLACK FOS FACE OF STUDS SF SQUARE FEET BY TESTING ACCORDING TO ASTM E 1190 BY A QUALIFIED INDEPENDENT TESTING AGENCY. DELIVER EXTRA MATERIALS TO OWNER. VINYL EDGE. FOW FACE OF WALL SH SHELF 3. WIRE HANGERS: ASTM A 641/A 641M, CLASS 1 ZINC COATING, SOFT TEMPER, 0.162-INCH DIAMETER. 1. QUANTITY: [3] THREE PERCENT, BUT NOT LESS THAN 1 GAL OF EACH MATERIAL AND COLOR APPLIED. PART 2 - PRODUCTS SECTION 1500 - MECHANICAL REFER TO MECHANICAL/PLUMBING PLANS FIR FIRE RATED/RETARDANT SHT SHEET FRP FIBERGLASS REINFORCED SLM SIMILAR 4. CARRYING CHANNELS: COLD -ROLLED, COMMERCIAL -STEEL SHEET WITH A BASE METAL THICKNESS OF 0.0538 INCH ,A MINIMUM 1/2-INCH- WIDE FLANGE, AND IN DEPTH INDICATED. 2.1 MANUFACTURERS A. PRODUCTS: AS LISTED IN THE FINISH SCHEDULE. SECTION 160D - ELECTRICAL REFER TO ELECTRICAL PLANS POLYESTER PANEL SL SLIDING FRTW FIRE RETARDANT TRTD. WD. SPEC SPECIFICATION 5. FURRING CHANNELS (FURRING MEMBERS): 1. BENJAMIN MOORE & CO. (BENJAMIN MOORE . ) URR FFr ORTING FEET SQ SQUARE A. AS INDICATED ON DRAWINGS. C. GRID SUSPENSION SYSTEM FOR INTERIOR CEILINGS: ASTM C 645, DIRECT -HUNG SYSTEM COMPOSED OF MAIN BEAMS AND 2. SHERWIN -WILLIAMS CO. (SHERWIN-WILLIAMS). SS STAINLESS STEEL ST STAIN CROSS -FURRING MEMBER$ THAT INTERLOCK. 3. GLIDDEN CO. (THE GLIDDEN COMPANY). G GRAPHIC STD STANDARD D. PARTITION AND SOFFIT FRAMING: 4. PPG INDUSTRIES INC. (PPG). G GROUT STL STEEL GA GAUGE STOR STORAGE o 1. AS INDICATED ON DRAWINGS. 2.3 TRIM ACCESSORIES A. INTERIOR TRIM: ASTM C 1047. 5. SHERWIN-WILLIAMS CO. (SHERWIN-WILLIAMS). 3. OR EQUAL AS APPROVED BY SPRINT PROJECT MANAGER 2.2 PAINT MATERIALS, GENERAL GALV GALVANIZED SSTRUCTURAL GB GRAB BAR SUSPSP SUSPENDED GC GENERAL CONTRACTOR SYM SYMMETRICAL .. 2.4 JOINT TREATMENT MATERIALS A. MATERIAL COMPATIBILITY: PROVIDE BLOCK FILLERS, PRIMERS, AND FINISH -COAT MATERIALS THAT ARE COMPATIBLE WITH ONE GL GLASS A. GENERAL: COMPLY WITH ASTM C 475. ANOTHER AND WITH THE SUBSTRATES INDICATED UNDER CONDITIONS OF SERVICE AND APPLICATION, AS DEMONSTRATED BY GND,GRND GROUND T TEMPERED B. JOINT TAPE: MANUFACTURER BASED ON TESTING AND FIELD EXPERIENCE. GWB GYPSUM WALLBOARD T TILE 1. INTERIOR GYPSUM WALLBOARD: PAPER. B. MATERIAL QUALITY: PROVIDE MANUFACTURER'S BEST -QUALITY PAINT MATERIAL OF THE VARIOUS COATING TYPES SPECIFIED GYP GYPSUM TEL TELEPHONE 2. EXTERIOR GYPSUM SOFFIT BOARD: PAPER. THAT ARE FACTORY FORMULATED AND RECOMMENDED BY MANUFACTURER FOR APPLICATION INDICATED. PAINT -MATERIAL THK THICK, C. JOINT COMPOUND FOR INTERIOR GYPSUM WALLBOARD: FOR EACH COAT USE FORMULATION THAT IS COMPATIBLE WITH OTHER CONTAINERS NOT DISPLAYING MANUFACTURER'S PRODUCT IDENTIFICATION WILL NOT BE ACCEPTABLE. HB HOSE BIBB THICKNESS HC HANDICAPPED TOS TOP OF STEEL COMPOUNDS APPLIED ON PREVIOUS OR FOR SUCCESSIVE COATS. C. COLORS: AS CALLED OUT IN FINISH SCHEDULE. HD HEAD TOW TOP OF WALL PART 3 - EXECUTION 3.1 NON -LOAD -BEARING STEEL FRAMING INSTALLATION 2.3 PREPARATORY COATS A. CONCRETE UNIT MASONRY BLOCK FILLER: HIGH-PERFORMANCE LATEX BLOCK FILLER OF FINISH COAT MANUFACTURER AND HDWD HARDWOOD TT TOILET TISSUE HDWR HARDWARE DISPENSER A. GENERAL: COMPLY WITH ASTM C 754, AND ASTM C 840 REQUIREMENTS THAT APPLY TO FRAMING INSTALLATION. RECOMMENDED IN WRITING BY MANUFACTURER FOR USE WITH FINISH COAT AND ON SUBSTRATE INDICATED. HM HOLLOW METAL TYP TYPICAL B. SUSPENDED CEILING AND SOFFIT FRAMING: 2.4 INTERIOR FINISH COATS HORIZ HORIZONTAL 1. SUSPEND CEILING HANGERS PLUMB AND FREE FROM CONTACT WITH INSULATION OR OTHER OBJECTS WITHIN CEILING A. INTERIOR SEMI -GLOSS ALKYD ENAMEL: HR HOUR UNF UNFINISHED PLENUM THAT ARE NOT PART OF SUPPORTING STRUCTURAL OR CEILING SUSPENSION SYSTEM. SPLAY HANGERS ONLY 1. AS CALLED OUT IN FINISH SCHEDULE. LION UNLESS HT HEIGHT OTHERWISE WHERE REQUIRED TO MISS OBSTRUCTIONS AND OFFSET" RESULTING HORIZONTAL FORCES BY BRACING, COUNTERSPLAYING, PART 3 - EXECUTION HVAC HEATING, VENTILATING, NOTED OR OTHER EQUALLY EFFECTIVE MEANS. 3.1 APPLICATION AIR CONDITIONING 2. WHERE WIDTH OF DUCTS AND OTHER CONSTRUCTION WITHIN CEILING PLENUM PRODUCES HANGER SPACINGS THAT A. EXAMINE SUBSTRATES, AREAS, AND CONDITIONS, WITH APPLICATOR PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR INTERFERE WITH THE LOCATION OF HANGERS REQUIRED TO SUPPORT STANDARD SUSPENSION SYSTEM MEMBERS, INSTALL PAINT APPLICATION. SUPPLEMENTAL SUSPENSION MEMBERS AND HANGERS IN FORM OF TRAPEZES OR EQUIVALENT DEVICES. SIZE B. COORDINATION OF WORK: REVIEW OTHER SECTIONS IN WHICH PRIMERS ARE PROVIDED TO ENSURE COMPATIBILITY OF THE SUPPLEMENTAL SUSPENSION MEMBERS AND HANGERS TO SUPPORT CEILING LOADS WITHIN PERFORMANCE LIMITS ESTABLISHED BY REFERENCED STANDARDS. TOTAL SYSTEM FOR VARIOUS SUBSTRATES. ON REQUEST, FURNISH INFORMATION ON CHARACTERISTICS OF FINISH MATERIALS TO ENSURE USE OF COMPATIBLE PRIMERS. C 1 O ABBREVIATIONS PLAN CHECK COMMENTS 1 1 20 05 / 3. ATTACH HANGERS TO STRUCTURAL MEMBERS. DO NOT SUPPORT CEILINGS FROM OR ATTACH HANGERS TO PERMANENT C. REMOVE HARDWARE AND HARDWARE ACCESSORIES, PLATES, MACHINED SURFACES, LIGHTING FIXTURES, AND SIMILAR ITEMS 1 ISSUED FOR PERMIT AND BID 1/7/04 METAL FORMS, STEEL DECK TABS, STEEL ROOF DECKS, DUCTS, PIPES, OR CONDUIT. ALREADY INSTALLED THAT ARE NOT TO BE PAINTED. IF REMOVAL IS IMPRACTICAL OR IMPOSSIBLE BECAUSE OF SIZE OR C. PARTITION AND SOFFIT FRAMING: WEIGHT OF THE ITEM, PROVIDE SURFACE -APPLIED PROTECTION BEFORE SURFACE PREPARATION AND PAINTING. No. Revisions / Submissions Date 1. WHERE STUDS ARE INSTALLED DIRECTLY AGAINST EXTERIOR WALLS, INSTALL ISOLATION STRIP BETWEEN STUDS AND WALL 1. AFTER COMPLETING PAINTING OPERATIONS IN EACH SPACE OR AREA, REINSTALL ITEMS REMOVED USING WORKERS 2. EXTEND PARTITION FRAMING FULL HEIGHT TO STRUCTURAL SUPPORTS OR SUBSTRATES ABOVE SUSPENDED CEILINGS, EXCEPT WHERE PARTITIONS ARE INDICATED TO TERMINATE AT SUSPENDED CEILINGS. CONTINUE FRAMING OVER FRAMES FOR DOORS AND OPENINGS AND FRAME AROUND DUCTS PENETRATING PARTITIONS ABOVE CEILING TO PROVIDE SUPPORT SKILLED IN THE TRADES INVOLVED. D. SURFACE PREPARATION: CLEAN AND PREPARE SURFACES TO BE PAINTED ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS FOR EACH PARTICULAR SUBSTRATE CONDITION AND AS SPECIFIED. DOOR MARK ROOM ROOM NAME & DESCRIPTION 1 PARTITION KEY - WALL TYPES DETAIL NUMBER CARRILLO FOR GYPSUM BOARD. 1. PROVIDE BARRIER COATS OVER INCOMPATIBLE PRIMERS OR REMOVE AND REPRIME. TAG.* 3. FRAME DOOR OPENINGS TO COMPLY WITH GA-600 AND WITH GYPSUM BOARD MANUFACTURER'S APPLICABLE WRITTEN RECOMMENDATIONS, UNLESS OTHERWISE INDICATED. SCREW VERTICAL STUDS AT JAMBS TO JAMB ANCHOR CLIPS ON 2. CEMENTITIOUS MATERIALS: REMOVE EFFLORESCENCE, CHALK, DUST, DIRT, GREASE, OILS, AND RELEASE AGENTS.R ROUGHEN AS REQUIRED TO REMOVE GLAZE. IF HARDENERS OR SEALERS HAVE BEEN USED TO IMPROVE CURING, USE 101 ROOM INDICATOR TAG Ode THE DETAIL. DTL __ DETAIL MARK A R C H I T E C T U R A L G R O UP I N C WALL /PARTITION DOOR FRAMES; INSTALL RUNNER TRACK SECTION (FOR CRIPPLE STUDS) AT HEAD AND SECURE TO JAMB STUDS. MECHANICAL METHODS OF SURFACE PREPARATION. ROOM NUMBER SHT J. Steven Carrillo 11231 Gold Express Dr. A. INSTALL TWO STUDS AT EACH JAMB, UNLESS OTHERWISE INDICATED. 3. FERROUS METALS: CLEAN UNGALVANIZED FERROUS -METAL SURFACES THAT HAVE NOT BEEN SHOP COATED; REMOVE OIL, 101 DOOR NUMBER ROOM PARTITION TYPES SHEET NUMBER A.I.A. C11.222 Gold RiSuite ver, CA 95670 "' "" 4. FRAME OPENINGS OTHER THAN DOOR OPENINGS THE SAME AS REQUIRED FOR DOOR OPENINGS, UNLESS OTHERWISE GREASE, DIRT, LOOSE MILL SCALE, AND OTHER FOREIGN SUBSTANCES. USE SOLVENT OR MECHANICAL CLEANING DETAIL 916 266-6000 FAX 266-6006 m INDICATED. INSTALL FRAMING BELOW SILLS OF OPENINGS TO MATCH FRAMING REQUIRED ABOVE DOOR HEADS. METHODS THAT COMPLY WITH SSPC'S RECOMMENDATIONS. DOOR COLUMN GRID LINE THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY D. Z-FURRING MEMBERS: ERECT INSULATION VERTICALLY AND HOLD IN PLACE WITH Z-FURRING MEMBERS. 3.2 PANEL PRODUCT INSTALLATION A. TREAT BARE AND SANDBLASTED OR PICKLED CLEAN METAL WITH A METAL TREATMENT WASH COAT BEFORE PRIMING. 12 FIXTURE TAG RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, A. GYPSUM BOARD: COMPLY WITH ASTM C 840 AND GA-216. B. TOUCH UP BARE AREAS AND SHOP -APPLIED PRIME COATS THAT HAVE BEEN DAMAGED. WIRE -BRUSH, CLEAN WITH SOLVENTS RECOMMENDED BY PAINT MANUFACTURER, AND TOUCH UP WITH SAME PRIMER AS THE SHOP COAT. 12 - -- - -- -- - -- --�-- O SHEET NOTES - Al REVISIONS MARK CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE DRAWING IS NOT 4. GALVANIZED SURFACES: CLEAN GALVANIZED SURFACES WITH NONPETROLEUM-BASED SOLVENTS SO SURFACE IS FREE OF NEW WORK NOTE FIXTURE TAG NUMBER COLUMN REFERENCE MARK FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT. SECTION 09511 - ACOUSTICAL PANEL CEILINGS OTOCK BY MECHAN CANT MINAN S. REMOVE PRETREATMENT FROM GALVANIZED SHEET METAL FABRICATED FROM COIL SHEET NOTES FIXTURE TAG COLUMN REFERENCE GRIDS REVISIONS Drawing Title PART 1- GENERAL- 1.1 SUMMARY E. MATERIAL PREPARATION: 1. MAINTAIN CONTAINERS USED IN MIXING AND APPLYING PAINT IN A CLEAN CONDITION, FREE OF FOREIGN MATERIALS AND S P E C I I- I CST I O N S A. THIS SECTION INCLUDES ACOUSTICAL PANELS AND EXPOSED SUSPENSION SYSTEMS FOR CEILINGS. PART 2 - PRODUCTS PA2.MANUFACTURERS A. PROVIDE ACOUSTICAL PANEL CEILINGS WITH EXPOSED SUSPENSION GRID AS SHOWN AND SCHEDULED ON THE DRAWINGS, RESIDUE. 2. STIR MATERIAL BEFORE APPLICATION TO PRODUCE A MIXTURE OF UNIFORM DENSITY. STIR AS REQUIRED DURING APPLICATION. DO NOT STIR SURFACE FILM INTO MATERIAL. IF NECESSARY, REMOVE SURFACE FILM AND STRAIN MATERIAL BEFORE USING. A.F.F. CUT LINE SECTION NUMBER �. HEIGHT DATUM ELEVATION NUMBER TA- �--- FURNITURE TAG / TOILET ACCESSORY ELV ELV 10'-0" CEILING HEIGHT TAG CUT OR ELEVATION MARK Seal �_� Drawn Checked AND SPECIFIED HEREIN. 2.2 GENERAL F. EXPOSED SURFACES: INCLUDE AREAS VISIBLE WHEN PERMANENT OR BUILT-IN FIXTURES, GRILLES, CONVECTOR COVERS, �- SECTION MARK SHT SHT SHEET NUMBER P-1 FINISHES TAG FURNITURE TAG % SHT AR D Cyf TCB NSH COVERS FOR FINNED -TUBE RADIATION, AND SIMILAR COMPONENTS ARE IN PLACE. EXTEND COATINGS IN THESE AREAS, AS SHEET NUMBER A. ACOUSTICAL PANEL STANDARD: COMPLY WITH ASTM E 1264. B. METAL SUSPENSION SYSTEM STANDARD: COMPLY WITH ASTM C 635. "DIRECT REQUIRED, TO MAINTAIN SYSTEM INTEGRITY AND PROVIDE DESIRED PROTECTION. 1. PAINT SURFACES BEHIND MOVABLE EQUIPMENT AND FURNITURE THE SAME AS SIMILAR EXPOSED SURFACES. BEFORE FINISHES TOILET ACCESSORY SECTION ELEVATION INDICATOR Cl 0, Project No. 04139.66 C. ATTACHMENT DEVICES: SIZE FOR FIVE TIMES THE DESIGN LOAD INDICATED IN ASTM C 635, TABLE 1, HUNG," FINAL INSTALLATION OF EQUIPMENT, PAINT SURFACES BEHIND PERMANENTLY FIXED EQUIPMENT OR FURNITURE WITH Date UNLESS OTHERWISE INDICATED, PRIME COAT ONLY. D. WIRE HANGERS, BRACES, AND TIES: ZINC -COATED CARBON -STEEL WIRE; ASTM A 641/A 641M, CLASS 1 ZINC COATING, SOFT TEMPER. 2. PAINT INTERIOR SURFACES OF DUCTS WITH A FLAT, NONSPECULAR BLACK PAINT WHERE VISIBLE THROUGH REGISTERS OR GRILLES. A7 �° GRAPHICS o. CI 22 1-7-05 E. METAL EDGE MOLDINGS AND TRIM: TYPE AND PROFILE INDICATED OR, IF NOT INDICATED, MANUFACTURER'S STANDARD 3. PAINT BACK SIDES OF ACCESS PANELS AND REMOVABLE OR HINGED COVERS TO MATCH EXPOSED SURFACES. 9 REN % 5 Scale MOLDINGS FOR EDGES AND PENETRATIONS THAT FIT ACOUSTICAL PANEL EDGE DETAILS AND SUSPENSION SYSTEMS INDICATED; FULL FORMED FROM SHEET METAL OF SAME MATERIAL, FINISH, AND COLOR AS THAT USED FOR EXPOSED FLANGES OF 4. FINISH EXTERIOR DOORS ON TOPS, BOTTOMS, AND SIDE EDGES THE SAME AS EXTERIOR FACES. 0�� F C Drawing No. SUSPENSION SYSTEM RUNNERS. -3 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 1 11 12 SP11W 48" MIN. 48" X 10" 30" 30" 24" 1 d' 3Y' PULL SIDE ,, 48" MIN. I 24" MIN, CLEAR AT MAX] MAX ? EXTERIOR DOORS _ Z = 18" MIN. I,CLEAR AT INTERIOR DOORS 1446 SANTA ANA CA _ XZ CO �' SOUTH COAST PLAZA / 12" MIN. 3611 SOUTH BRISTOL ST. x M :2 PROVIDE 12" * PROVIDE THIS ADDITIONAL 12" SPACE SUITE B Z Z 48" MIN. 48" MIN. ADDITIONAL SPACE t IF DOOR IS EQUIPPED IF D00& IA CLLO ER.D WITH BOTH A TCH PUSH SIDE WITH BOTH A SANTA ANA, CA 92704 LATCH & A CLOSER. DOOR IN SERIES PROJECT TEAM HIGH FORWARD MAX. FORWARD REACH OVER CLEAR FLOOR SPACE MAXIMUM SIDE REACH HIGH AND LOW OWNER'S PROJECT MANAGER REACH LIMIT AN OBSTRUCTION PARALLEL APPROACH OVER OBSTRUCTION SIDE REACH LIMITS 48" MIN. FRONT APPROACH TRAMMELL CROW NOTE: NOTES: = X SHALL BE LESS THAN OR EQUAL TO 25 INCHES. Z SHALL BE GREATER THAN OR EQUAL TO X. WHEN X IS LESS THAN 20 INCHES, THEN Y SHALL 1. MINIMUM CLEAR FLOOR SPACE ALLOWING FOR FORWARD OR PARALLEL APPROACH I � SPRINT PCS PROJECT MANAGER 6100 SPRINT PARKWAY BE 48 INCHES MAX. WHEN X IS 20 TO 25 INCHES, THEN Y SHALL BE 44 BY A WHEEL CHAIR SHALL BE PROVIDED AT CONTROLS, DISPENSERS, RECEPTACLES PULL SIDE INCHES MAX. AND OTHER EQUIPMENT. 36 MIN. * * Mailsto KSOPHK0410-4A554 p 2. THE HIGHEST OPERABLE PART OF CONTROLS AND MECHANISMS SHALL BE PLACED z z � � OVERLAND PARK, KS 66251 PHONE; (913) 315-5110 WITHIN AT LEAST ONE REACH RANGE BASED UPON DIRECTION OF APPROACH AND CONTACT: RON GERARD ron.d.gerard®mail.sprint.com OBSTRUCTIONS. -► N 3. ELECTRICAL AND COMMUNICATION SYSTEM RECEPTACLES ON WALLS SHALL BE MOUNTED NO LESS THAN 15" ABOVE FLOOR. OUTLETS AND RECEPTACLES NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS NOT REQUIRED TO COMPLY. BOTH DOORS OPEN OUT ARCHITECT CARRILLO ARCHITECTURAL GROUP, INC. 4. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND I I 11231 GOLD EXPRESS DR., SUITE 103 SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. z 48" GOLD RIVER, CA 95670 THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. MIN. 54" MIN. � a. PHONE: (916) 266-6000 PUSH SIDE *� FAX: (916) 266-6006 � G l REACH RANGES CONTACT: HATE HENINGER nateheningerC�carrilloag,com * NOTE: 48" MIN. IF DOOR HAS MEP ENGINEERS BOTH A LATCH & A CLOSER � � HENDERSON ENGINEERS NTS PER SECTION 11 B C.B.C. HINGE APPROACH DOORS AT OPPOSITE WALLS 8325 LENEXA DRIVE, SUITE 400 FLUSH ACTIVATOR TO EDGE OF GENERAL SIGNAGE NOTES: LATCH SIDE LENEXA, KS 66214 ON WIDE SIDE WATER CLOSET CENTERLINE OF FIXTURE. CENTERLINE OF FIXTURE. INTERNATIONAL SYMBOL OF ACCESSIBILITY: 5 PULL PHONE: (913) 307-5464 CENTERLINE CENTERLINE �� 18" FLUSH ACTIVATORBACKGROUND,- 1 g FLUSH ACTIVATOR 1. WHITE FIGURE AND BORDER ON BLUE SIDE FAX: 913 307-5400 ( ) OF FIXTURE OF FIXTURE ON WIDE SIDE ON WIDE SIDE 48"CONTACT: 18" 18" MIN. 32 MIN. TO 32 MIN, TO o 19„ COLOR NO.15090 IN FEDERAL STD, 595E LETTERS AND NUMBERS: 1. 1" MINIMUM LETTER HEIGHT. ADA ROOM TREVOR JONES trevor.Jones®hendersonengineers.com LANDLORD INVESTCORP / ORANGE BRISTOL, LP 28° WATER F EDGE OF \ MAX. 2. WIDTH -TO -HEIGHT RATIO BETWEEN 3:5 AND 1:1 IDENTIFICATION 2CD `0 ~ CLOSET 10 WDTH HEIGHT RATIO BETWEN 1:5 AND 1: CD SIGN CLOSEET CLEAR 4. CONTRAS3. T AIRACTERS AND SYMBOL WIETH BACKGROUND. 5. SANS SERIF' CHARACTERS, UPPERCASE. DOOR I 280 PARK AVE, 36TH FLOOR NEW YORK, NY 10017 N z FLOOR p N 60" MIN. � n � SPACE RAISED AND RECESSED CHARACTERS AND SYMBOLS: MOUNTED 1. LETTERS AND NUMBERS MINIMUM 1/32". SIGN z 24" MIN. PHONE: (212) 577-1414 CONTACT: HEATHER MUTTERPERL 00 Zck� 36L DIA. CLR. _ 2. RAISED SYMBOLS MINIMUM 5/8" TO MAXIMUM 2" HIGH. vo " \ / BRAILLE: 1. USE CONTRACTED GRADE 2 BRAILLE. DOTS SHALL BE 0.1 * PUSH SIDE 32" MIN. Z MIN. � 48" MIN. CLR.cc) INCH ON CENTER IN EACH CELL. 2. 0.2 INCH SPACE BETWEEN CELLS. 3. DOTS RAISED MINIMUM 0.025 INCH ABOVE BACKGROUND. DOORS AT ADJACENT WALLS *NOTE: 48" MIN. IF CLH. Ll PICTOGRAMS: DOOR HAS A CLOSER VESTIBULE NOTES: 1. BORDER DIMENSION OF PICTOGRAM SHALL BE A MINIMUM OF 6° LATCH APPROACH HIGH. 1. SPACE BETWEEN TWO CONSECUTIVE ADDITIONAL STALL 2. PICTOGRAMS SHALL BE ACCOMPANIED BY EQUIVALENT DOORS IN A VESTIBULE, IN OTHER THAN SINGLE OCCUPANCY MULTIPLE TOILET STALL MULTIPLE TOILET STALL w/ OUTWARD ACTING DOOR CLEAR FLOOR SPACE VERBAL DESCRIPTION DIRECTLY BELOW. DOOR CLEAR SPACE A STAIRWAY EXIT, SHALL PROVIDE A MIN. ET TOILFRONT ENTRY SIDE ENTRY AND PARALLEL GRAB BARS. AT LAVATORIES EXTERIOR SIGNS: 48" CLEAR BETWEEN DOORS IN 90' OPEN „ " 36 GRAB BA " MI 36" 12 48" GRAB BA 1 1 2 1 1 /4" TO 1 1/2 NOMINAL 60 12" DIAMETER. MAX. 1. REFLECTORIZED PORCELAIN ON STEEL WITH BEADED TEXT AND SYMBOL, UNLESS NOTED OTHERWISE. 2. WHITE FIGURE AND TEXT ON BLUE BACKGROUND, COLOR NO.15090 IN FEDERAL STD. 595a. 32" MIN. POSITION AND OPPOSITE WALL OR DOOR. CLR. VESTIBULES C-D_ _� z_ CL ``'1� a I.- CO =b z Z '?'� TYPE "1": WOMEN'S TOILET ROOM DOORWAY SIGN, 12" DIAMETER, 1/4" THICK WITH FEMALE PICTOGRAM AND LETTERING STATING 900 LEVER LATCH PUS, BAR PULL PLATE, U" SHAPED HANDLE PANIC BAR. STOP Iq o I- a �� WOMEN". FINISH OF BACKGROUND SHALL CLEAR OPENINGS MUST BE BETWEEN - _ €� FRAMING AND N N p� _ M WOMEN DISTINCTLY CONTRAST DOOR. MOUNT THE DOOR IN ITS 99 OPEN POSITION ACCESSIBLE OR BLOCKING AT +60 A.F.F. TO CENTERLINE AND THE FACE OF THE STOP. - ENTRANCE SIGN, AS REQUIRED T-SHAPED SPACE " 8 MIN. KNEE 6C' OF SIGN, CENTERED ON DOOR o ON OR ADJACENT SINGLE DOOR DOOR. 0 60" DIAMETER SPACE n FOR 180' TURNS rgj CLEARANCE LEMARANCEE �; TO � NAGE GENERAL E N WATER CLOSET SECTION THROUGH MIN. 32 MIN. NOTES AND SIGN SIDE ELEVATION TYP. GRAB BAR WHEELCHAIR TURNING SPACE LAVATORY CLEARANCES GENERAL NOTES: WATER CLOSETS: TYPE 2'. O cli CLR. o z TYPE "7". A. PROVIDE ROOM IDENTIFICATION SIGNS AT ENTRANCE TO TOILET ROOMS. REFER TO 1. SEAT HEIGHT 17" TO 19" ABOVE FLOOR WITH 2" HIGH TOILET SEAT. WOMEN'S TOILET ROOM WALL SIGN WITH �\ FEMALE PICTOGRAM LETTERING AND BRAILLE SOLID BOTTOM RAIL OR KICK PLATE -14 90 SIGNAGE, DETAILS AND NOTES. PROVIDE SIGN TYPES "1 "2", "3", AND 'W AND 2. CONTROLS OPERABLE WITH ONE HAND NOT REQUIRING TIGHT GRASPING, PINCHING OR STATING "", � WOMEN". MOUNT AT +60 A.F.F. INSTALL AT APPROPRIATE ROOM LOCATIONS. TWISTING OF WRIST, AND LOCATED ON WIDE SIDE OF TOILET AREA. MAXIMUM HEIGHT WOMEN TO CENTERLINE OF SIGN, ADJACENT TO STRIKE SIDE OF DOOR. DOOR CONFIGURATION B. ROOM ENTRANCE DOORS SHALL PROVIDE CLEARANCES AS REQUIRED FOR DOOR OF CONTROLS 44" ABOVE FLOOR WITH MAXIMUM FORCE TO ACTIVATE OF 5 POUNDS. CLEAR OPENINGS FOR TWO LEAF DOORS CLEARANCES. REFER TO DOORS AND DOORWAY DETAILS AND NOTES. URINALS: MUST BE BETWEEN EITHER DOOR IN ITS MULTIPLE-ACCOMODATION TOILET ROOMS 1. RIM PROJECTION FROM WALL MINIMUM 14" AND AT A MAXIMUM OF 17' ABOVE FLOOR. TYPE "3": 90' OPEN POSITION AND THE EDGE a X XN OF THE OTHER DOOR. � 2. CONTROLS SAME AS FOR WATER CLOSETS. 2 1. WHEELCHAIR CLEAR SPACE SHALL BE A MINIMUM 60" DIAMETER, OR 56 BY 63' MEN'S TOILET ROOM DOORWAY SIGN, DOUBLE DOOR a1 RECTANGLE, TO 27" ABOVE FLOOR. DOORS OTHER THAN ACCESSIBLE TOILET STALL LAVATORIES: 1/4" THICK WITH MALE PICTOGRAM AND LETTERING STATING "MENFINISH DOORS MAY ENCROACH INTO CLEAR SPACE BY NOT MORE THAN 127. 1. MINIMUM OF 18" FROM ADJACENT WALL TO CENTERLINE OF FIXTURE. OF BACKGROUND SHALL DISTINCTLY DOOR CLEARANCE & FLOOR SPACE: 2. ACCESS OF NOT LESS THAN 44" SHALL BE PROVIDED AND CONNECT ALL ACCESSIBLE 2. MINIMUM FLOOR CLEAR SPACE OF 30" X 48". ELEMENTS WITHIN TOILET ROOM. 3. RIM OR COUNTER MAXIMUM 34 ABOVE FLOOR WITH MINIMUM MEN CONTRAST DOOR. MOUNT AT +60" A.F.F. TO CENTERLINE OF SIGN, 1. DOOR CLEAR FLOOR SPACE ON EACH COMPRESSED CARPET 1/4' MAX. BELOW 1 PLAN CHECK COMMENTS 1 /20/05 29 HIGH KNEE CLEARANCE CENTERED ON DOOR. SIDE OF DOOR SHALL BE LEVEL EXCEPT \ ISSUED FOR PERMIT AND BID 1/7/04 3. SPACE IMMEDIATELY IN FRONT OF ACCESSIBLE WATER CLOSET COMPARTMENTS SHALL FROM FRONT EDGE 8" DEEP AT TOP. MINIMUM 9" HIGH TOE CLEARANCE FROM „ 12 AT EXTERIOR LANDINGS WHICH MAY THRESHOLD BE 48" MINIMUM MEASURED AT RIGHT ANGLES TO THE COMPARTMENTS DOOR IN ITS FRONT EDGE 17" DEEP AT FLOOR. SLOPE A MAXIMUM OF 1/4:12. FINISH FLOOR EVEN CLOSED POSITION. 4. HOT WATER AND DRAIN PIPES INSULATED OR COVERED, WITH NO EXPOSED SHARP 2. AT DOUBLE DOORS AT LEAST ONE LEAF No. Revisions / Submissions Date 4. ACCESSIBLE COMPARTMENT DOORS SHALL BE OUTWARD ACTING SELF -CLOSING, AND OR ABRASIVE SURFACES. PROVIDED WITH HANDLES AND LATCHES WHICH REQUIRE NO GRASPING OR TWISTING. 5. CONTROLS OPERABLE WITH ONE HAND NOT REQUIRING TIGHT GRASPING, PINCHING OR DOOR SHALL HAVE AN UNOBSTRUCTED OPENING OF 32" CLEAR FOR SIDE ENTRY. TWISTING OF WRIST. MAXIMUM FORCE TO ACTIVATE OF 5 POUNDS. SELF -CLOSING TYPE "4": SHALL PROVIDE THE MIN. CLEAR OPENING. ' THRESHOLD 3. CLEAR FLOOR SPACE AT DOORS IS MEWSCARRILLO MEWS TOILET ROOM WALL SIGN WITH DEPENDENT UPON DOOR SWING, DOORS WITH MINIMUM 9" BOTTOM CLEARANCE TO FLOOR AREA NOT REQUIRED TO VALVES SHALL REMAIN OPEN FOR MINIMUM OF 10 SECONDS. MALE PICTOGRAM LETTERING ANP BRAILLE HARDWARE ON DOOR AND DIRECTION OF THRESHOLD NOTES: HAVE 18" STRIKE CLEARANCE. GRAB BARS: STATING "MEN". MOUNT AT +60 A.F.F. APPROACH. REFER TO DOOR SCHEDULE IN 1, CHANGES IN LEVEL GREATER THAN 1/2 ARCHITECTURALGROUPINC J. Steven Carrillo 11231 Gold Express Dr. 5. ADDITIONAL 36" WIDE STALL SHALL BE PROVIDE WHEN TOILET ROOM HAS 6 OR MORE �. 1. MOUNT AT 33 ABOVE FLOOR, EXCEPT AT TANK TYPE WATER CLOSET ALLOW 36 MEN TO CENTERLINE OF SIGN, ADJACENT TO STRIKE SIDE OF DOOR. ADDITION TO PLAN AND TYPICAL DETAILS. SHALL BE ACCOMPLISHED BY MEANS A.I.A. C11.222 Suite 103 Gold 95670 i STALLS. STALL SHALL HAVE OUTWARD ACTING SELF CLOSING DOOR AND PARALLEL ABOVE FLOOR AT BACK OF STALL. OF A RAMP. 2River, 6o OA FAX 266-6006 - m SIDE GRAB BARS. > > 2. SIDE BARS 48 LONG, FRONT END POSITIONED 24 FROM FRONT END OF WATER CLOSET. THE ARCHITECT, CARRILLO ARCHITECTURAL GROUP INCORPORATED, HEREBY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN 6. WATER CLOSETS IN ACCESSIBLE COMPARTMENTS SHALL BE LOCATED TO PROVIDE 18" BACK END WITHIN 12" OF BACK WALL. WALL DOOR WIDTH THRESHOLDS THESE PLANS, IDEAS AND DESIGNS WHICH ARE NOT TO BE REPRODUCED, FROM SIDE TO CENTERLINE OF FIXTURE, 32" FROM SIDE WALL TO EDGE OF BOWL 3. REAR BARS 36' LONG. TYPE " CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE AND 48" FRONT CLEARANCE AT FRONT ENTRY STALLS OR 60" FRONT CLEARANCE AT 4. BAR DIAMETER 1 1/4" TO 1 1/2" WITH 1 1/2" SPACE BETWEEN WALL AND BAR. : 5" EXPRESS WRITTEN PERMISSION FROM THE ARCHITECT. THE DRAWING IS NOT SIDE ENTRY STALLS. 7. URINALS CLEAR FLOOR SPACE SHALL BE 30" X 48" IN FRONT OF URINAL TO PROVIDE 5. BAR, FASTENERS AND MOUNTING DEVICES SHALL WITHSTAND 250 POUNDS BENDING, '�'� ACCESSIBLE ENTRANCE SIGN FINAL OR TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT, Drawing Title FORWARD APPROACH. SHEAR AND TENSILE FORCE. DECAL FOR GLASS, MOUNTED HARDWARE: 1. LOCK OR LATCH SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL SINGLE-ACCOMODATION TOILET ROOMS: 6. BARS SHALL NOT ROTATE IN FITTINGS. ;t, CENTERLINE OFFSIGN, TO BE TITLE 24 1. WHEELCHAIR CLEAR SPACE SHALL BE MINIMUM 60 DIAMETER OR T-SHAPED PER ACCESSORIES: " VISIBLE FROM BOTH SIDES 2. LOCK ORGLATCH EFFORT. HALT BE OPERABLE WITH SINGLE EFFORT WITHOUT REQUIRING GRASPING. INTERIOR,/'DETAILS T-SHAPED SPACE FOR 180 DEGREE TURNS. DOOR SHALL NOT ENCROACH INTO CLEAR SPACE. 1. MIRRORS MOUNTED WITH BOTTOM EDGE MAXIMUM IT ABOVE FLOOR. 2. DISPENSING AND WASTE RECEPTACLES MOUNTED WITH ALL DISPENSERS AND OPERABLE 3. MAXIMUM EFFORT TO OPERATE DOORS NOT TO EXCEED 5 POUNDS AT EXTERIOR Seal Drawn Checked 2. WATER CLOSETS SHALL BE LOCATED TO PROVIDE 18" FROM SIDE WALL TO CENTERLINE OF " PARTS AT MAXIMUM 40 ABOVE FLOOR. AND 5 POUNDS AT INTERIOR, AT FIRE DOORS 15 POUNDS WHEN APPROVED BY ° TCB NSH FIXTURE, 28" FROM AN ADJACENT FIXTURE TO EDGE OF BOWL AND 48" FRONT CLEARANCE. 3. TOILET PAPER DISPENSER WITHIN 12 OF FRONT EDGE OF WATER CLOSET. DISPENSERS THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 4. PANIC HARDWARE SHALL ACTIVATE AND DOOR OPERATE WHEN A ,ARC � �l Project No, 3. IN EXISTING BUILDINGS, SINGLE-ACCOMODATION TOILET ROOMS MAY HAVE WATER CLOSETS THAT CONTROL DELIVERY OR DO NOT PERMIT CONTINUOUS PAPER FLOW ARE NOT ALLOWED. MAXIMUM FORCE OF ,� �� 04139.66 Q LOCATED IN AREAS PROVIDING 36' X 48" CLEAR SPACES IN FRONT OF THE WATER CLOSET. CONTINUOUS FEED ROLL TYPE DISPENSERS SHALL BE PROVIDED AT ACCESSIBLE STALLS. 15 POUNDS IS APPLIED. ' 1� {� N f a Date Al TOILET ROOMS AND FIXTURES A7 INTERIOR SIGNAGE A10 �` DOORS AND DOORWAYS J' C1 ,2 2 '-7-05 Scale ,N. ; _. _4� FULL OF l�O NTS PER SECTION 111513.7 C.B.C. NTS PER SECTION 1117B.5®1 C.B.C. NTS PER SECTION 1133B C.B.C. i Drawing No. G-5 1 2 3 4 5 6 7 18 19 10 11 12