HomeMy WebLinkAbout10147850.pdfxt. L T ANALYSIS AREA (E) S.F.R. AND GARAGE 1,956 S.F. (N) ROOM ADDITION 257 S.F. (N) PORCH 126 S.F. TOTAL LOT RATIO 2,339 S.F. LOT SIZE 6,780 S.F. % LOT COVERAGE 34% PLOT PLAN SC= 1/8"= V-0" ,j q,- c I . ....... .... - . ............ 41- I FLOOR PLAN SIC= 1/491= 11.011 7L--- p-�iS-uk3� ,tvN-�S AM��� K O-W \N X, 1 Tb P,kiF-PARFD BY . ......... L 714 285 1121 2017 W. ALCO AVE. SANTA A N A CALIFORNIA 92703 MAC I ELALOMSN. COM REVISIONS Owner. JUDITH TORRES Ph 17141434-3912 DRAWN CHECKED DATE SCALE joB No. SHEET Aml rf%vnvw WIN a.0nvnff`lv REVISIONS I BY I ------- 2- i = L::1 m r NORTH ELEVATION SC=1/4=V-0" SOUTH ELEVATION SC= 1/4"= V-0" ELM: j k 4 "I �l "I ELEVATION NOTES 1. ASPHALTH SHINGLE CLASS 'B' OR BETTER OVER # 15 FELT UNDERLAYMENT, TO MATCH (E) S.F.R 2. 2 x FASCIA TO MATCH (E) S.F.R. 3. STUCCO OVER APPROVED LATHE & BUILDING PAPER - COLOR BY OWNER, TO MATCH (E) S.F.R. 4. FOUNDATION VENTS 12"x6" MIN., PROVIDE I SQ. FT. FOR EACH 160 SQ.FT. OF UNDER FLOOR AREA, USE CORROSION - RESISTANT WIRE MESH WITH WIRE MESH OPENINGS OF 1/4" IN DIMENSION. 6. UNDER FLOOR ACCESS AREA 18" x 24" MIN. W/ WIRE MESH COVER. DRAWN CHECKNO OATS SCALE Joe NO. SHEET A® 'Milli r_u VI'll 9-LC#knrmlfv I luuum REVISIONS I BY 'LOOR SHEATING %" T&G PLYWOOD W/ 8d @ 6" o/c EN/EN & 8d @ 10" o/c FIELD i ;4'� i ink I Tb ISTimt, -f6c,- 0i 1.4 1 1 r I Lb ;u'= ROOF SHEATING 1/2" CDX, 2410 INDEX PLYWOOD W/ 8d COMMON NAl' @r .FIELD. PROVIDE '•• BARRIER PLYWOOD UNDERSIDE ROOFING MATERIAL ASPHALTH SHINGLE BETTER TO MZA UNDERLAYMENT FOUNDATION PLAN SC /4"= V-0" SECTION A 5C=,/<=,.o• ROOF FRAMwG PLAN gC=„a••,•-0• SHEAR WALL SCHEDULE 1997 U.B.0 i SILL BOLTING MARK WALL TYPE ALLOWABLE EXTERIOR INTERIOR SILL NAILING @ SHEAR WALLS WALLS UPPER STORIES 7/8" STUCCO OVER PAPER BACKED LAT W/16 GA STAPLES @ 6" O/C @TOP & BOTTOM PLATES, g EDGE OF SHEAR WALL AND ON FIELD (ICBO REPORT No. 1823, FEB, 1973) OR (ICBO No,1318, 180 PLF 5/8 @ 55" 0/C 5/8 @ 55" O/C 16d @ 8" O/C FEB,1973) OR (ICSO No.1254, FEB 1972) NOTE 4 AND 9 BELOW 3/8" PLYWO SRUCT It OR STD SHTG WITH 8d NAILS @ 6" O/C @ EDGES & 12" O/C FIELD 260 PLF 5/8 @ 3S" O/C 518 @ 38" O/C I Sd @ 6" O/C (TABLE 23-114-1 U.B.C.) NOTE 1,9,10 & 11 BELOW A r1, 3/8" PLYWD SRUCT II OR STD SHTG WITH 8d NAILS @ 4" O1C @ EDGES & 12" 01C FIELD 350 PLF 518 @ 26" OIC 5/8 @ 26" O/C 16d @ 4" O/C (TABLE 23.11-1-1 U.S.C.) NOTE 1, 6, 9,10 & I BELOW 318" PLYWD SRUCT II OR STD SHTG WITH 8d NAILS @ 4" OIC @ EDGES & 12" O/C FIELD 380 PLF 518 @ 26" O/C 5/8 @ 26" O/C 16d @ 4" 0/0 (TABLE 23•II-I-1 U.B.C. NOTE 1, 3, 5, 6, 9,10 & 11 BELOW 3/8" PLYWD SRUCT II OR STD SHTG WITH 8d NAILS @ W O/C @ EDGES & 12" OIC FIELD 490 PLF 5/8 @20" O/C 5/8 @ 20" 0/C 16d @ " (TABLE 23-i1-i-1 U.S.C.)NOTE 1, 3, 5, 6, 9,10 & 11 BELOW 31/2" 010 3/8" PLYWD SRUCT II OR STD SHTG WITH 8d NAILS @ 2" O/C @ EDGES & 12" O/C FIELD 610 PLF 618 @ 16" O/C 518 @ 16" O/C 16d O/ CTABLE 2341-1-1 U.B.C. NOTE 1, 3, 5, 6, 9, 10 & 11 BELOW 2 1/2" O/C 1 1 /2" STRUCT IPLYWD WITH 10d NAILS @ 2" OIC @ EDGES & 12" O/C FIELD 870 PLF 3/4 @ 16" O/C 3/4 @ 16" O/C NIA OVER 3X.51 UDS i I ABLE 23-11-1-1 U.B.C. NOTE 1, 3, 5, 6, 9,10 & 11 BELOW NOTES: 1: ALL EDGES OF PLYWOOD SHEARWALLS MUST BE BLOCKED WITH 24 SOLID BLOCKING FOR WALLS TYPES 9 & 10, AND 3 x SOLID BLOCKING FOR WALLS TYPES 11, 12.13 & 14 2.- WHERE SHEAR WALL SHEATING IS TO BE APPLIED TO BOTH SIDES IF WALL, DOUBLE THE NUMBER OF BOLTS. (I.E. HALF THE O/C SPACING) 3,- USE 3 x PRESSURE TREATED DOUGLAS FIR SILL PLATES AT FOUNDATIONIFIRST FLOOR ONLY 4.- PAPER BACKED SELF FURRING EXPANDED METAL LATH 1080 APPROVAL 5: GRAMING AT ADJOINING PANEL EDGES SHALL BE 3- INCH NOMINAL OR WIDER & NAILS SHALL BE STAGGERED 6.- WHERE PLYWOOD IS APPLIED ON BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 5' OIC ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3- INCHES NOMINAL OR THICKER & NAILS ON EACH SIDE SHALL BE STAGGERED 7 - ALL CONTINUOUS EXTERIOR FOOTING TO HAVE 518" x 10" A.6.'s @ 48" OIC UNLESS OTHERWISE NOTED ON PLANS 8: ALL INTERIOR BEARING AND NON BEARING FOOTINGS TO HAVE 7132" SHOT PINS @ 32" O/C & 48" O/C RESPECTIVELY: I.E. OZARK # H•671C80 REPORT 1280, MAY 1987 9: USE 2112 x 21/2" x 3716" PLATE WASHERS 10: USE CDX CC OR STD SHTG IN LIEU OF SRUCT it PLYWOOD. ALL PLYWOOD SHALL BE DOUGLAS FIR. OTHER SPECIES MAY REQUIRE CHANGES. I I. -AT EXISTING FOOTINGS USE REDHEAD WEDGE ANCHORS TO COMPLY WITH SILL BOLTING ICSO# 1372 MIN EMBED 711T DRAWN CHECKED DATE SCALIB _ --- eJOB WO. SHEET sm 1 PRINTED ON CLEARPRINT 1000H GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 C.B.C. PLUMBING AND MECHANICAL CODES, THE C.E.C. AND LOCAL ORDINANCES. 2. VERIFY ALL DIMENSIONS, DO NOT SCALE DRAWINGS. 3. IT SHALL BE THE RESPONSABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON THE SITE PRIOR TO COMMENCING WORK AND IS TO NOTIFY THE OWNER AT ONCE C UPON DISCOVER OF ANY OMISSIONS OR CONFLICT IN THE DRAWINGS. 4. ALL NAILING TO COMPLY WITH TABLE 23-II-B-1 C.B.C. 5. ALL PLUMBING WALLS TO BE 2" x 6" G. DOUBLE WALLS USED AS PLUMBING WALLS ARE TO BE A MINIMUM OF 8" WIDE AND NO "FLAT" STUDS PERMITTED. STAGGERED STUDS ARE ACCEPTABLE. 7. SMOOTH, HARD, NON ABSORBENT SURFACE IS PROVIDED TO A HEIGHT OF 70" ABOVE THE DRAIN INLET OF THE SHOWER OR TUB/SHOWER COMBINATION MATERIALS I S SHALL BE OF A TYPE NOT ADVERSELY AFFECTED BY MOISTURE. 8. GLASS ENCLOSURE DOORS AND PANELS MUST BE LABELED CATEGORY II. NET AREA OF SHOWER RECEPTORS SHALL BE NO LESS THAN 1024 SQ IN OF FLOOR AREA, AND ENCOMPASS 30"DIAMETER CIRCLE. 9. ALL WATER CLOSETSMARE LOCATED IN A CLEAR SPACE NOT LESS THAN 30" WIDTH AND HAVE 24" MIN. CLEARANCE IN FRONT OF THE STOOL. 10. FOR EXHAUST VENTILATION AIR, PROVIDE MECHANICAL FAN 5 AIR CHANGES PER HOUR. 11. RECEPTACLE OUTLETS LOCATIONS WILL COMPLY WITH NEC Art 210- 52 (a) 1120 AMP. CIRCUIT DEDICATED TO EACH BATHROOM" 12. ALL BEDROOM CIRCUITS REQUIRE ARC -FAULT PROTECTION. 13. GROUND -FAULT CIRCUIT INTERRUPTER (GFI) PROTECTION COMPLIES WITH NEC Art. 210-8: "ALL 125 volt SINGLE PHASE, 15 AND 20 AMPERES RECEPTACLES INSTALLED IN BATHROOMS, GARAGES, BASEMENTS, OUTDOORS, KITCHEN COUNTERS AND AT WET BAR SINKS. 14. WATER HEATER TO BE BRACED TO RESIST SEISMIC FORCES, PROVIDE TWO STRAPS (ONE STRAP AT TOP 113 OF THE TANK AND ONE STRAP AT BOTTOM 113 OF THE TANK). 15. THE MANUFACTURED WINDOWS SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE NATIONAL FENESTRATION RATING COUNCIL (NFRC) AND SHOWING COMPLIANCE WITH THE ENERGY CALCULATIONS. 16. THE CONTRACTOR SHALL PROVIDE ANY SHORING AND/OR BRACING TO THE EXISTING STRUCTURE WICH MAY BE REQUIRED DURING CONSTRUCTION. 17. PERMISSIBLE NOTCHING AND BORING OF JOISTS ARE TO BE SHOWN ON THE PLANS AND SHALL NOT EXCEED CBC SECTION 2320.8.3 ALLOWANCES, 18. NOTCHING OF EXTERIOR AND BEARING/NONBEARING WALLS SHALL NOT EXCEED 25%140% RESPECTIVELY. BORED HOLES IN BEARING/NONBEARING WALLS SHALL NOT EXCEED 40%160% RESPECTIVELY. IN NO CASE SHALL THE EDGE OF THE BORED HOLE NEARER THAN 518" T O THE EDGE OF THE STUD (2320.11.9 AND 320.11.9 AND 19. HEADER AND TRIMMER DETAILS FOR DOORS AND WINDOWS ARE TO BE SHOWN WITH THE FULL LENGTH TRIMMERS, SPECIFYING THE SIZE OF THE HEADER AND TRIMMER (2320.11.6) 20. USE SIMPSON ST 6224 TO TIE-IN TO EXISTING TOP PLATES. SANTA ANA POLICE DEPARTMENT RESIDENTIAL SECURITY REQUIREMENTS I STRUCTURAL NOTES CONCRETE I. ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR WEIGHT HARD ROCK TYPE (150 `CU FT) AGREGATES SHALL BE NATURAL SAND AND ROCK CONFORMING TO ASTM C-33 WITH PROVEN SHRINK AGE CHARACTERISITCS OF LESS THAN 0.05 %_ 2.- READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94 PLACEMENT OF CONCRETE SHALL CONFORM TO ACI 301. 3: CEMENT FOR ALL CONCRETE SHALL BE PORTLAND CEMENT TYPE V OR BLOW ALKALL CONFORMING TO ASTM C-150. 4.- MINIMUM COMPRESSIVE STRENGHT OF CONCRETE AT AGE OF 28 DAYS FOR: FOOTINGS 2,500 PSI SLAB OR GRADE 2,500 PSI SIDEWALKS 2,000 PSI 5- MAXIMUM SLUMP SHALL NOT EXCEED 4". 6.- CONCRETEH 5 ALL BE MAINTAINED IN A MOIST CONDITION FOR A MINI MUM OF 5 DAYS AFTER PLACEMENT. ALTERNATIVE V METODS WILL BE APPROVED PR VED IF SATISFACTORY PERFOR MANCE CAN BE ASSURED. 7.- ALL REINFORCING STEEL ANCHOR BOLTS, DOWELLS AND OTHER INSERTS SHALL BE SECURELY FASTENED IN THE FORMS BEFORE CONCRETE N RETE IS POURED. ADEQUATE C LEANOUTS SHALL BE PROVIDED IN BOTTOM OF CONCRETE FORMS FOR PROPER CLEANOUT AND INSPECTION. 8: VIBRATION OF CONCRETE SHALL BE IN ACCORDANCE WITH THE GENERAL PROVISIONS OUTLINED IN PORTLAND CEMENT ASSOCIATION SPECIFICATIONS ST-26. 9.- EXPOSED CORNERS OF COLUMNS, BEAMS, WALLS, ETC., SHALL BE FORMED WITH %"CHAMFERS UNLESS DETAILED OTHERWISE, 10.- CONCRETE CONTRACTOR SHALL BE SUBMIT PROPOSED CONCRETE DESIGN MIX TO THE ARCHITECT AND ENGINEER OF RECORD, PRIOR TO STARTING THE WORK. 11 - NO WATER SHALL BE ADDED TO CONCRETE WITH TEMPERATURE IN EXCESS OF 95' F. 12 WIRE MESH LAP (END & SIDE) SHALL BE ONE FULL MESH -2 PLYWOOD I.- PLYWOOD SHEETS SHALL BE COX CONFORMING TO PS 1-95 AND SHALL BE STAMPED WITH THE DRPA GRADE OF THE AMERICAN PLYWOOD ASSOCIATION, UNLESS NOTED OTHERWISE ON THE PLANS. 2: EACH SHEET SHALL HAVE A MINIMUM AREA OF 8 SQ. FT. WITH A MINIMUM DIMENSION OF 2 FEET. 3.- SEE FRAMING PLAN FOR DIAPHRAGM NAILING SHEDULE, NAILING SHALL BE INSPECTED AND APPROVED BEFORE COVERING. FOUNDATION NOTES 'I.- FOUNDATION HAS BEEN DESIGNED ASSUMING MINIMUM ALLOWABLE DOIL BEARING PRESSURE PER 2001 UNIFORM BUILDING CODE SHALL BE AS FOLLOWS: CONTINUOUS FOOTING 1,000 P.S.F. ISOLATED FOOTING 1,000 P.S.F. 2: ALL FOOTINGS SHALL BE FOUNDED ON OR BELOW FIRM UNDISTURBED NATURAL SOIL OR APPROVED COMPACTED FILL AND ADJACENT FINISH GRADE UNLESS NOTED OTHERWISE. 3.- ALL FOOTING SHALL BE CENTERED ON PLASTER AND/OR WALL AND COLUMN UNLESS OTHERWISE NOTED. 4: FINISH FLOOR (F.F) EXCAVATION SHALL BE AS NOTED ON GRADING PLANS. 5: THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ANY ADJACENT PROPERTY STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES, 6.- ALL FOOTINGS SHALL BE FORMED TO MEET SIZES INDICATED ON DRAWINGS, DErAILS AND/OR SHEDULES. 7.- ALL FOOTINGS AND PIERS SHALL BE CENTERED UNDER THE BUILDING COLUMNS (U.N.O,) 8.- ALL EXISTING UTILITIES THAT INTERFERE WITH THE STRUCTURAL FOUNDATIONS SHALL BE REMOVED AND RELOCATED. 9 - ALL PIPES, DUCTS AND CONDUITS WITHIN THE SPHERE OF INFLUENCE OF THE FOOTING (THE PRESSURE ZONE, EXTENDING BELOW THE FOOTING, BASED ON A 2 HORIZONTAL TO 1 VERTICAL SLOPE) SHALL BE SLEEVED THROUGH CONCRETE CAST -IN -PLACE ATTHE FOUNDATION POUR. 10.- FOUNDATION MAY BE SUBJECT TO TRUCTURAL REVISION IN THE FIELD DUE THE POSSIBLE VARYING SUBSURFACE CONDITIONS. LUMBER 1 - ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR LARCH CONFORMING TO DIVISION 23 (2001 C.B.C). 2: RAFTER, BEAMS, PURLINS SHALL BE DOUGLAS FIR NO. UNLESS OTHERWISE NOTED. 1.- _ Exterior swinging doors must be solid core, 13/4" thick or with panels 9/16 thick (8-210,A) 2.- Doors leading from a garage into a dwelling unit must be sold core, 1 3/8 thick (8-210,13) 3.- Specify that above doors be equipped with deadbolt locks approved by the Police Department (8-210,C) specify make and model number (titan 780 or equal) 4.- Specify flush bolts with 5/8 imbedment into head and threshold on inactive leaves of exterior double doors (8-210, E) 5.- Glazing in exterior doors or within 40" of the latch must be tempered or burglary resistant (8-2 10, F) 6.- Hinges for out swinging doors must have non -removable pins (8-2 10, G) 7.- Strike plates must be 3 '/" long, secured to the jamb with screws 2 '/z" in length ((8-210,14) 8.- Front exterior doors to be equipped with 180' doors viewers or clear vision panels (8-210, I) 9.- Each stricture must have a street address or other identification which is visible from the street. Figures must be. 4" minimum in height of a color contrasting to the background (8-2 10, K1) l0:- Provide an illuminated plot plan of the complex at each driveway entrance (8-2 10, K2) I I.- Specify light fixtures, at exterior doors, which provide one -foot candle of light at ground level. (8-210, L). 12.- Exterior walkways, passageways within multiple dwelling complexes must be provided with 0,25 foot candle of light (8-210, Ivl). 13.- Parking lots and parking structures of multiple dwelling complexes must be provided with one foot candle of light (8-210,N) 14.- Required exterior light fixtures must be vandal resistant type. 15.- Wooden garage doors must have panels 5/16" in thickness (8-208, Al) 16.- Garage doors more than 16 feet in width must have two locking points (8-208,C) 17.- Slide bolt assemblies must be attached to the doorframe with non -removable bolts (8-208,D) 18.- The slide bolt must be 3/8" in diameter (8-208,D) 19 - Windows and sliding glass doors must comply with test standards of section 8-212. Specify make and model number (8-209,A) (if not approved must install slide bolts and permanent path -lift devices in upper track of windows and doors) 20.- Louvered windows may not be used within 12' vertically or 6' horizontally from any walkable surface. 21.- All skylights shall be provided with rated burglary resistant glazing (8-210) 3- GRADE JOIST, PURLINS 2" TO 4' WIDE, 6 & DEEPER No. 1 BEAMS, PURLINS OVER 4" WIDE No. 1 SUBPURLINS 2" TO 4" WIDE, 6 & DEEPER No. 1 LEDGERS No.2 STUDS 2"x 4" OR Tx 4" STUDS STUDS 2" x 6" No. 1 POSTS 5" x 5" AND LARGER No. 1 SILLS, PLATES AND BLOCKING No. 2 4-SILLS AND PLATES IN CONTACT WITH CONCRETE OR MASONRY AND WITHIN 48" OF GROUND, SHALL BE PRESSURE TRESTED DOUGLAS FIR (PTDF) SILLS SHALL BE BOLTED TO THE FOUNDATION WITH 518" DIAMETER x 10" LONG BOLTS AT 48' ON CENTER 12" MINIMUM FROM ENDS OR TWO BOLTS MINIMUM PER PIECE, INLESS OTHERWISE NOTED. 5: STUD WALLS ABUTING A CONCRETE OR MASONRY WALL, SHALL BE BOLTED TO THE WALL WITH 518' ANCHOR BOLTS AT 24" 01C. 6: ALL NON BEARING STUD WALLS, SHALL BE 2" x STUDS AT 16" 0/C WITH 518" GYP. BOARD EACH SIDE, UNLESS OTHERWISE NOT ED. ED. 7.- ALL STUD WALLS SHALL HAVE A E FULL HEIGHT 1" x 6" - DIAGONAL LEFT IN BRACES AT ENDS AT INTERVALS NOT EXCEEDING 25 FEET OIC UNLESS OTHERWISE NOTED ON PLANS, BRACES SHALL COVER A MINIMUM OF SIX STUD SPACES. &- COMMON NAILS E SHALL 8 USED. 9.- FIRE BLOCKING 2' x 1 % " THICK, SHALL BE PLACED IN STUD WALLS AT CEILING AND FLOOR LEVELS AT EACH 10' HEIGHT OF STUDS AND BETWEEN STAIR STRINGERS AT SUPPORTS. 10.- JOISTS SHALL BE BNLOCKED AT SUPPORTS AND BRIDGED OR BLOCKED AT INTERVALS OF 8' WHERE JOISTS ARE 2' x 12' OR DEEPER, 11.- MAXIMUM UNSUPPORTE HEIGHT FOR NON -BEARING PARTITION SHALL BE: 2" x 4- @ 16" O/C UP TO 14--o" 2" x 6" @ 16" O/C UP TO 20'-0" 2' x 8" @ 16" OIC UP TO 26'-0" 12.- PROVIDE DOUBLE JOISTS UNDER PARALLEL BEARING PARTITION WALLS. 13.- BOLTS HOLES IN WOOD MEMBERS SHALL BE A MINIMUM 1/32" AND A MAXIMUM 1/16" LARGER THAN THE BOLT DIAMETER, REINFORCING STEEL 1.- REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BEARS AS FOLLOWS: FOOTING, SLAB ON GRADE, MASONRY AND BENT DOWELLS, TIES: # 3 BAR AND SMALLER ASTM A- 615 GRADE 40 # 4 BAR AND LARGER ASTM A- 615 GRADE 60 2: DEFORMATION OF REINFORCING SHALL BE IN ACCORDANCE WITH ASTM A-305 AND BENDING IN ACCORDANCE WITH ACI-318-95. 3-MINIMUM ONCRETE COVER OVER REINFORCING REBAR FOR (EXCEPT AS NOTED OTHERWISE) NOT EXPOSED TO WEATHER OR EARTH 1^ EXPOSED TO WEATHER 1 y EXPOSED TO EARTH 2" PILASTER, BEAM & COLUMN TIES 1 % FORMED FOOTING AND WALL EXPOSED TO EARTH 2" UNIFORMED FOOTING AND WALL EXPOSED TO EARTH 3" SLAB ON GRADE 2- 4.-SPLICE IN CONCRETE: MINIMUM OF 36 BAR DIAMETER OR 12' WICHEVER IS GREATER. 5: WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 AND 1-82. 6: ALL DETAILING OF REINFORCING SHALL CONFORM TO THE REQUIREMENTS OF ACI 318-95 7: ALL REINFORCING STEEL, DOWELS, ANCHOR BOLTS, INSERTS, ETC, SHALL BE SECURED PLACE PRIOR TO PLACING ANY CONCRETE OR GROUT. 8.- ALL REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-615 GRADE 60. 9.- ALL REINFORCING BAR BENDS SHALL BE MADE COLD 10: ALL REINFORCING BARS SHALL BE FREE FROM GREASE, RUST, MILL SCALE OR ANY OTHER FOREIGN MATERIAL WISH MAY AFFECT THE BARS ABILITY TO BOND TO THE MORTAR. II. REINFORCEMENT THAT IS PARTIALLY EMBEDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT AS SPECIFICALLY DETAILED IN THESE DRAWINGS OR WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER OF RECORD. 12.-ALL REINFORCING STEEL SHALL BE PROVIDED AT ALL POUR JOINTS ON THE DRAWINGS, WHERE LAP AND/OR SPLICE LOCATIONS ARE NOT SPECIFICALLY INIDICATED, PROVIDE CLASS 'C' SPLICE PER SCHEDULE. ALL SPLICE LOCATIONS SHALL BE CLEARLY SHOWN ON SHOP DRAWINGS AND APPROVED BY ENGINEER OF RECORD BEFORE FABRICATION. 13- PLACING TOLERANCES AND BAR SUPPORTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR REINFORCING CONCRETE CONSTRUCTION BY WCRSL 14.- CLEARANCE BETWEEN PARALLEL BARS IN A LAYER SHALL NOT BE LESS THAN V NOR 1 BAR DIA NOR 1x MAX AGRAGATE SIZE. BARS IN SECOND LAYER SHALL BE DIRECTLY ABOVE BARS IN FIRST LAYER, MIN DISTANCE BETWEEN LAYERS 1". I,A prlL / I. 11 I� ter. - T1 9 -'? - 141 V Fr -,l 1.),44/_. Z)C 12'�D �Ch �N�U�. Cox-����ot�•� .__. I X f O. U I n is _ ,1�tlj is / „ fl rLooI", -j-1 1 N1 F- 11 i N� (j or4�=E-oGK�� o` 7 %�i Jt2f,K ' � ', i Po�T 0-11p r rlj�� scHEQULE TYPE HD2A HD5A H06A HDBA HDIaA My/IyA 2-5/8 2--3/4 3-3/4 3-7/8 4-7/8 HB 4 1/ 5 1 6 1/ 1/8 6 1 8 SIB 2 1/ 3' 3 1/2 3,1/2r3/4' CL 1 1 $ 1 1 1 1 2 1 i Sp 1/4 1/2 3/4'3/4' SSTBI 16 20 28 28 IaL� 12' 16' 24' 24' 24' 20 24 34 34 34 e 16' 200 28" 28" 28' X1 0E WIN 2775 4010 5100 7460 9540 K VOW 2775 4010 5100 1 7460 1 9540 CL 3-1/2• 2X STUD 11 �_ (F111.ER) POST PER PUN (4X MIN) I18 PER SCHED HPOOLO M (HDA) it -'11 0 1 22XR 32X 2X �C'SON PER PLAN MIN. Le SSIB' "Mum sCHF.Dt1L.E 3' MN. CLR. NQiE C0NCI&IE STEIt wAt1S SFY�1 ° LOADS BASED ON WIN 0 POST SIZE OR 6'MN 0i5 WIDTH FOR 5/8'! AN(21A(N( ANCHOR LOAD. MN WIDTH FOR 7/9.0 ANCHORS 8' MN FOR CONC. RDCX NOTE: FOR USED FOUNDATION USE SSTB FOR TWO POUR SYSTEM AND EXTEND BOLT BEYOND SILL PLATE ABOVE FLOOR SHEATHING H OLDOYYiV "PHD OR HO PER - PLANS do SIMPSON CATALOG DRILL. HOLES 1/16" LARGER THAN BOLT DIA- .s USE EQUIVALENT PHD ;U W/ E,N. EXISTING FOOTING THREADED ROD I W/ EPDXY I.C,B.O } 4945 CITY OF LA .R, 0 25185 W/ SP. INSPE TION USE (ET22) U.N.O. HDA BOLT EDGE W EMBEDMENT ALLOWABLE TENSILE OR DLL (M) LOAD CONCRETE COMPRESSION PHD (IN.) (IN.) (M.) (IN.) fc b 20M (ET22) HD2A 5/8 1-3/4 6 12 2775 HD5A 5/8 1-3/4 6 12 4010 HD6, 8A 7/8 1-3/4 8 15 5100, 7460 •1. • • USE SIMPSON SET EPDXY ICBO #ER5279 OR R.R. #25279 NOTE: FOR RAISED FLOOR USE LONGER BOLTS) TO EXTEND ABOVE FLOOR SHEATHING HCLDOWN TO EXIST. FOOTING 0 REVISIONS 1 BY 1 DRAWN CHECKEO DATE SCALE JOB NO. SHEET SD=l PRINTED ON CLEARPRINT 1000H.