HomeMy WebLinkAbout10142968.pdfREVISION DATE Aladdin Express Bail Bonds NORTH REV. A 02 22 04 Jeff Dougherty m FIRE DEPARTMENT C❑MMENTSI COUNTY ASSESSOR'S PARCEL LOT NUMBER APN 010-121-10 321 W. 17th St. 'I\ Santa Ana, CA 92706 FIRE DEPARTMENT FINAL INSPECTION REQUIRED. SCHEDULE ALL Phone 714-541-9700 � � r- INSPECTIONS 24 HOURS IN ADVANCE. PHONE (714) City of Santa Ana C0 `O `j 2. — PROVIDE 2A 1OBC MINIMUM RATED FIRE EXTINGUISHERS TO BE Ln r__ d- LOCATED ON FLOOR WITHIN 30/75 FEET OF TRAVEL DISTANCE Plan Check N o , 10142968 Address 321 W, 17 T H S T , _ Ile) FROM ALL AREAS. PROVIDE A 4013C MINIMUM RATED FIRE I I I 3, — STORAGE, DISPENSING, OR USE OF ANY FLAMMABLE OR COMBUSTIBLE Contact Person: Phil Robles Phone NO, 714-335-6865 LIQUIDS, FLAMMABLE GASES, AND HAZARDOUS CHEMICAL SHALL 1 HTH 0 O COMPLY WITH UNIFORM FIRE CODE REGULATIONS. OZ M i _ Ld m O W 4.— SHOW JOB ADDRESS ON ALL PLANS. Checked byl SHAMBHU KAYASTHA Datel 02/11/04 W ALLEY WAY "� ¢ � 5. - PROVIDE AN OCCUPANT LOAD SIGN OF--_-------- TO BE POSTED W U : Z m NEAR THE MAIN EXIT. (-------------- SO. FT. PER PERSON) w w Z Q 2: J M Applicable Code 2001 CBC, 2001 CPC, 2001 CMC, 2001 CEC 17TH O z 6,- A "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" SIGN 0 Q p Q Q > Z J low WITH MINIMUM ONE (1) INCH LETTERS SHALL BE PROVIDED U) Z m F_ � W W ADJACENT TO EXIT DOOR ------------- J O O N❑ Z _ U � Occupancy B/S1 Flood Zone Q o Q CL Cn Lij v o 0_ 7, _ Approval of plans is predicated on making the following U) o Cf) m 714-647-5863 Ld corrections. All checked items indicated corrections or additions. Type of Construction �-N Phone NO, Q A R0 .�, Submit in person three (3) sets of revised plans (same sets as for Building Department), and a copy of this report to Fire Department � P ERM1 ` , TYP k ; LL Counter Plan Check at the Building Department, 20 Civic Center M.G5i`�w­ Plaza, Santa Ana, CA 92701. Counter Plan Check Hours ore: r'?,fo.,;. Ir o r G LM MAP LOCATION �y - loll CITY PUBLIC DATA r Fo 5. PARCEL LOT 002-153-23 FIRE DEPARTMENT FINAL INSPECTION REQUIRED. SCHEDULE ALL I ""'-"" "" •"° ' INSPECTIONS 24 HOURS IN ADVANCE. PHONE (714) 647-5700 / MULTI USE CODE CM �Lu 1, REMOVING INTERIOR NON BEARING WALLS TO ENLARGE EXISTING _.,._ O i CONST YEAR 1955 T WAITING AREA. ✓DESI �., . PI E _.Y F GN TYPE CM I FL01 ) c�i, CE t=. ,,. � PLANS. OCCUPANCY IS DEPARTMENT OCCUPANCY CLASSIFICATION ON NO. OF FLOORS 1 �j f, 7, — SHOW THE BUILDING DEPA �j ( %) ;�1i�°O' ..1 = (�.�/ TOTAL BLDG. SIZE 1,760 �' �. USE CODE CM EXITING REQUIREMENTS LAND SIZE SQ FT. 4,950 r,N,;_ 3, ADD HANDICAPPED PARKING REQUIREMENTS fNTaf T Pg r ;its' 32.- EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE MARCH 1948 ,al: OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. PROVIDE SELF— I _- �' RELEASING LOCKING DEVICES ON EXIT DOORS (NOTE ON PLAN). 4, ADD HANDICAPPED SIGNAGE REQUIREMENTS 'r w;4, `, I ORANGE GROVE TRACT L.A. 3-7 M.M. 2-9 GEOPPER'S ADD. L.A. 2-36,116 R.S. 6-39 r ►?eS %� �arkivf �- s; 33, — A SIGN THAT READS THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" WITH A MINIMUM ONE (1) INCH LETTERS SHALL BE ASSESSOR'S MAP SCOPE OF WORK PROVIDED ADJACENT TO EXIT DOOR ( FRONT ENTRANCE ) (NOTE ON PLANS). 06 BOOK 2 PAGE 15 COUNTY OF ORANGE TNe34. — "EXIT SIGNS SHALL BE IN BLOCK LETTERS, A MINIMUM OF SIX (6) � �i a 9 r y 9 �� r i bo �r' ��� COUNTY DATA 02 INCHES HIGH WITH A STROKE OF NOT LESS THAN 3/4" INCHES. � �" �' `��%� � s c: J+'�`� ,.� t^ta ; ^ +5s �. Dro@s ions Qi" ig5��v LUMINANCE ON FACE OF SIGN SHALL BE 50 LUX (NOTE ON PLAN). 35, — EXIT SIGNS SHALL BE PROVIDED IN ACCORDANCE WITH CURRENT EDITION OF C.B.C. AND C.F.C. SHOW LOCATION ON FLOOR OR DISABLED ACCESSIBILITY DOCUMENTATI❑N SANTA ANA P❑LICE SAFETY REQ ?EMq T REFLECTED CELING PLAN(S). 1133B.2,6 _IR 1. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT 1, ADAMS RITE HARDAWARE ` � AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, MS1850 - 1 3/8 INCH SWING BOLT UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO MS4002-AMOR STRIKE FIRE DEPARTMENT ADDENDUM COMMENTS, PF OPENED BY A WHEELCHAIR FOOTREST WITHOUT MS4043 SANTA ANA FIRE DEPARTMENT CREATING A TRAP OR HAZARDOUS CONDITI❑N, MS4085 1439 SOUTH BR❑ADWAY, SANTA ANA CA 92707 1133B.2.5.1 SANTA ANA FIRE DEPARTMENT 3, SCHL GE AL-SERI 2, HAND -ACTIVATED DOOR ❑PENING HARDWARE SHALL BE F.D. # SEE SH ET A- FOR HARDWARE DET CENTERED BETWEEN 30 INCHES AND 44 INCHES B.D. # THE FL❑OR. LATCHING AND LOCKING DO❑RSPR❑JECT AL10NPae h _AB❑VE TENTANT IMPR❑VEMENT THAT ARE HANDACTIVATED AND WHICH ARE IN A A125��'L�G❑CC. CLASS esPL PATH ❑F TRAVEL SHALL BE ❑PERABLE WITH A AL40Lock C ci,I�/ Ij/v4- ePLANS SINGLE EFF❑RT BY LEVER -TYPE HARDWARE, AL17y Trim REVIEWED BY C714) 647-5700 FIRE EXTEINGUISHING SYSTEM REQUIREMENTS 4, 6 INCH ADDRESS FRONT AND BACK COLOR MATCHING BACKGROUND U 5. LIGHT FIXTURE TO PROVIDE 1 FT. CANDLE. W INDEX SCHEDULE 03 0 m (0 O COMPLIANCE WITH CBC SECTION 1134/CHAPTER 11BI CD 20% OF COST OF REMODEL NEED TO BE EXPENDED FOR 0') I - ACCESSIBILITY UPGRADE, ALL NEW CONSTRUCTION NEED T Q Lo TO COMPLY WITH CHAPTER 11B FOR ACCESSIBILITY BY _ Q o DISABLED PERSONS, (IN ALPHABETICAL ORDER) w �' r �- N y a •U Q i� IL De11'r111�IiCI7 o 3�: o a� a II A. AN ACCESSIBLE ENTRANCE. t, Ux f s �„ o � o 3l°1I..�f~'i� C T t , ��° < na {✓ r N 1 i` lti Oi1� At�3�3 f EG s q 0 Q (n d { �­° B. AN ACESSIBLE ROUTE TO THE ALTERED AREA;` fiAOtilh'Cv U (7141 PROJECT NO. C. ACCESSIBLE RESTROOMS. C`3s"1FtI"I I3f I : "� CAI2s.a`*�- ae COMMENCED t M D. ACCESSIBLE TELEPHONE (IF ANY). T h9ld to alt - - -' per' E, ACCESSIBLE DRINKING FOUNTAINS, AND :; W,ca?as� of a,,Iv bu,, �, RA B b FEB 9 2005 PHIL ROBLES F, PARKING, SIGNAGE AND ALARMS. 4""� �a REVISIONS DATE 3r, w "� u z„ xi ._ sus jai i L 1. =, REV. A 02/22/04 r: a ,.. r PRIORITY SHALL BE GIVEN TO THOSE ELEMENTS THAT WILL SCALE 1 /16" = 1 PR❑VIDE THE GREATEST ACCESS IN THE ABOVE ORDER. ® COMPLETE AND SIGN ATTACHED DISABLED ACCESSIBILITY COCUMENTATION' 2/22/04 G 02/22 FORM FIRE NOTES: ADA NOTES: POLICE NOTES: DISABLED COMPLIANCE NOTES: 04Twl 1101 [§8] SHEET NUMBER DESCRIPTION T-1 INTR❑DUCTI❑N COVER SHEET T-2 EXISTING AND PROPOSED PLOT SITE A-1 EXISTING AND DEMOLITI❑N FLOOR PLAN A-2 ELECTRICAL/PROPOSED FLOOR PLAN (SMOKE DETECTORS) A-3 EXISTING ELEVATI❑N VIEWS: A-4 EXISTING/PR❑POSED REFLECTIVE CEILING FLOOR PLAN 6-1 GENERAL NOTES S-1 STRUCTURAL CUTTED ELEVATI❑N VIEWS ADA-1 ADA GENERAL NOTES AND DETAILS ADA-2 ADA GENERAL NOTES AND DETAILS � REVISION DATE REV. A 02/22/04 50'-0' 60'-0' 50'-0' 60'-0' u-) Ln DO �D � Do (7) (3) CO CO N I I � I I I NORTH NORTH Q co E ALLEY 13 0 ~ o m WAY �, o-�(E)ALLEY WAY 13 � 0:�W J W m z m � Q Lc) U : z m J O CD Q z J� -- m F-- X Q Q z z m Q � w � ' LEGEND LEGEND = Q w o Q a-— m U)0 >Ci- 1U WATER METER i 1O WATER METER GAS METER ( v I O2 GAS METER I O3 7 INCH CURB I I O3 7 INCH CURB I ® 1'-6" STREET GUTTER I ® " 1'-6" STREET GUTTER 1 I I O5 6 FT. HIGH STUCCO WALL I (� I I O5 6 FT. HIGH STUCCO WALL II © EXISTING BUSINESS BUILDING I © EXISTING BUSINESS BUILDING 5 I I O7 EXISTING ASPHALT SURFACE I I O7 EXISTING ASPHALT SURFACE ® SIDEWALK 5 7 I O I ® SIDEWALK I 9 ELECTRICAL METER I I O I i I O9 ELECTRICAL METER HANDICAPPED SIGNAGE In LF) I 11 I I 11 HANDICAPPED PARKING NEW 11 FT. WIDE CLEARENCE TO PROPERTY LINE ® 11 FT. WIDE CLEARENCE TO PROPERTY LINE O3 ALLEY WAY I I O3 ALLEY WAY I � ® ADJACENT BUILDING 14 ' Co ' O ADJACENT BUILDING 14 O5 AREA BEING SHARED WITH ADJACENT BUSINESS I Z I " I O5 AREA BEING SHARED WITH ADJACENT BUSINESS CD o K,�DA-N2 QO 11 8 8 02 1 o I� 10 D ' W ' 15 '� ' 15 o I I 18' — 0' coI I I I � I 3 I 3 I o I o J J W L i W I I W I W�W W W Q I < I I a 0 0 ' W 7 7 U) O o Aladdin Express Bail Bonds ( CD Express Bail Bonds I Jeff Dougherty I I Jeff Dougherty I O 321 W. 17th St. I 321 W. 17th St. ( c: Santa Ana, CA 92706 I Santa Ana, CA 92706 0. Phone 714-541-9700 I Phone 714-541-9700 z SQAURE FOOTAGE 1,760 SQAURE FOOTAGE 1,760 I s I I I I 12 12 I W I � I ❑ EY ❑ LY m CO O (E) DRIVEWAY (E) DRIVEWAY _ O O ENTRANCE/EXIT O 2 ENTRANCE/EXIT m 3 1O � � co �� 3 �, 4 Wes; �Q� L O 50'-0„ 501-01, o �i Q) c E N 0 = O Q D r0 (n 0- �� c� 4 '_ �� 24'_ 40,_0„ 24,_0PROJECT NO. COMMENCED CD CD I I W (U CU lf� Lf� HIL ROBLES REVISIONS DATE REV. A 02/22/04 SCALE 1 /16" = 1 FT - 02/22/04 SCALE 1/8" = 1 FT EXISTING PARKING LAYOUT O2 SCALE 1/8" = 1 FT PROPOSED PARKING LAYOUT loll Tm2 40'-6" 13'-8" 5'-5" nnnn anon ROOM NO. LOCATION AREA SQUARE FOOTAGE 100 WAITING AREA 175 SQUARE FOOTAGE 101 HALLWAY C 58 SQUARE FOOTAGE 102 BATH 1 32 SQUARE FOOTAGE 103 BATH 2 32 SQUARE FOOTAGE 104 ❑FFICE SUPPLY ROOM 87 SQUARE FOOTAGE 104A WATER HEATER 7 SQUARE FOOTAGE 105 OFFICE 171 SQUARE FOOTAGE 106 OFFICE 152 SQUARE FOOTAGE 107 ❑FFICE 150 SQUARE FOOTAGE 108 HALLWAY A 183 SQUARE FOOTAGE] 109 OFFICE 230 SQUARE FOOTAGE 110 ❑FFICE 81 SQUARE FOOTAGE 111 OFFICE 88 SQUARE FOOTAGE 112 HALLWAY B 86 SQUARE FOOTAGE 113 BATH 3 33 SQUARE FOOTAGE 114 CLOSET 29 SQUARE FOOTAGE 115 RECEPTION AREA B 89 SQUARE FOOTAGE 116 COPYING AREA 147 SQUARE FOOTAGE APPROXIMATE TOTAL SQUARE FOOTAGE 1,729 SQUARE FOOTAGE I 7 -/ ,I 7 -lU ,I J ___ __ J 40'-6" EXISTING FLOOR PLAN: NOTES: 1. MAKE REAR D❑OR TO SWING OUT WARD TOWARD HANDICAPPED STALL WITH DISABLED HARDWARE MOUNTED ( COST APPDXIMATE $500,00 ), 2. EXISTING DOOR TO REMAIN TO WATER HEATER CLOSET. 3, FRONT ENTRANCE DOUBLE DOORS DISABLED ACCESS HARDWARE TO BE MOUNTED C COST APP❑XIMATE $500,00 ), 4. FRONT ENTRANCE AND BACK ENTRANCE MUST REACH $1,000.00 OR MORE FOR DISABLED ACCESS COMPLIANCE USAGE, 5, EXISTING 2'-8" DOORS (TYPICAL) TO BE REMAIN, 6. CAP OFF EXISTING PLUMBING OUTLETS, DOOR SCHEDULE 1. SEE PAGE A-2 FOR DOOR SCHEDULE I i = DOORS TO BE REMOVED i i WALL LEGEND EXISTING WALLS TO REMAIN NON BEARING WALL PARTITI❑NS TO BE REMOVED IIIIIIIIIIIIINHHIIHHIHNIIIHIINIIIIIIIIIIIININNNNNNNIIINININIIIIIIiII NON BEARING WALL PARTITI❑N TO BE ADDED TO CLOSE ❑PENING WHERE DOOR EXISTED = 40'-6" H- O z 19'-9" NOTE 1 NOTE 4 t P, 4 1 A;C-IF S f t I Nr 494r'1 C 4040 4040 O BREAK ROOM OFFICE (CHANGE TO FILE ROOM) 230 SQ, ET i 150 SQ. FT i (U ro a 107 109 N❑TE 5 O � - OFFICE BATH 1 \3 (CHANGE TO FILE ROOM) HALLWAY A 33 SQ. �T NOTE 6 OFFICE 140 SQ, FT 183 SQ, FT 113 \ ��``` 81 SQ. FT 0 i 0 1 6 1 os 110 `� �,�'" CLOSET o / N❑TV' 3 29 SQ, FT I 04 O I II — � II � II � RECEPTION HALL JIB o o CCHANGEOF❑FICEE ROOM) AREA B 86 SQ. FTu -"-'� OFFICE CD 171 SQ. FT 85 SQ. FT 112 115 88 SQ, FT mj 105 � n I NOTE 4 t r II I I u u — BAT UTH32 SQ. FT 1 fj WAITING AREA SQ. FT w I ATTIC I 7104FT W�H 103 102 COPYING 175 SQ, FT w �QE� AREA 011 NOTE 2 147 SQ, FT 100 116 OFFICE SUPPLY R00 NOTE 3 87 SQ, FT HALLWAY C Fl-0-4-1 58 SQ, FT 101 NOTE 3 NOTE 4 i ROOM NO. LOCATION AREA SQUARE FOOTAGE 100 WAITING AREA 175 SQUARE FOOTAGE 101 HALLWAY C 58 SQUARE FOOTAGE 102 BATH 1 32 SQUARE FOOTAGE 103 BATH 2 32 SQUARE FOOTAGE 104 OFFICE SUPPLY ROOM 93 SQUARE FOOTAGE 105 ❑FFICE (WILL BE FILE ROOM SPACE) 171 SQUARE FOOTAGE 106 ❑FFICE (WILL BE FILE ROOM SPACE) 152 SQUARE FOOTAGE 107 ❑FFICE (WILL BE FILE ROOM SPACE) 150 SQUARE FOOTAGE 108 HALLWAY A 183 SQUARE FOOTAGE 109 OFFICE 230 SQUARE FOOTAGE 110 REMOVED PARTITION 81 SQUARE FOOTAGE 111 REMOVED PARTITION 88 SQUARE FOOTAGE 112 REMOVED PARTITION 86 SQUARE FOOTAGE 113 REMOVED PARTITION 33 SQUARE FOOTAGE 114 REMOVED PARTITION 29 SQUARE FOOTAGE 115 REMOVED PARTITION 89 SQUARE FOOTAGE 116 REMOVED PARTITION 116 SQUARE FOOTAGE APPROXIMATE TOTAL SQUARE FOOTAGE 1,729 SQUARE FOOTAGE 9'-7' 9'-10" 6'-6 13,-2„ 40'-6" DEMOLITION FLOOR PLAN: O z REVISION DATE REV. A 02 22 REV. B 02 02 REV. C 02/08/ In In 00 co QO I` DO rn rn CD c0 N I LO I r` I -- r� c9 Lf� I I I co 0 L,J O � r (j) LJ n, m J m z � z m w z Q Q Z J J O z m F- X Q m Q z O Q O Q z_ m Q J :D Q O _ Q w O Q m : (1) 0 > CL ■■ z 5 d cc 0 0 116 O J 0 W cl z 1• y C 0 m (0 O 00 0 I� m (N 0-) cy) I >, u Q d 0Lo Q I x o d 0' a� Lij < E E � n 0 a� �- 4 E o o C) � N N U Q--DI'9MIZ PROJECT NO. COMMENCED Dece per 30, 200 Q PHIL ROBLES z REVISIONS DATE REV. C 02/08/05 SCALE 1 /4" = 1 FT A-1,DWG 02/08/05 Aml 01 DIVISION 11 — ELECTRICAL: 1998 CA. ELECTRICAL CODE 1. All work shall be in full accordance with all codes, rules, regulation of governing agencies and shall comply with the requirements of the serving power and telephone companies. 2. The contractor shall verify availability of sevices and determine actual details pertaining to exact locations and requirements before submitting his bid, upon receipt of notice that electrical contract award has been made, successful bidder shall notify power and telephone serving utility companies of the estimated date when service shall be desired. 3. All materials and equipment furnished and installed under this section shall be quaranteed by the contractor for a period of one year from the date of acceptance of the work by the owner. 4. All equipment installed outdoors and exposed to weather shall be weatherproof, and G.F.I. protected. 5. Receptacles in kitchen and bathrooms shall be installed aboved worktop. Receptacles in bathrooms shall be G.F.I. protected. 6. Receptacles shall be installed vertically at 18"+ above floor. 7. Wall switches to be 48" above floor. 8. All electrically operated fixtures, outlets, equipment or devices whether installed by this conttractor or others, shall be fully connected to proper electrical source and left in operating condition. 9. Aluminum wire No. 4 AWG and smaller shall not be used in electrical wiring. SMOKE DETECTORS REQUIREMENTS NOTES: A. Smoke detectors shall Ice provided in all new construction, additions and interior alternations with a valuation over $1,000.00, In new buildings, smoke detectors shall be connected to the building wiring system and be provided with battery backup. In existing room smoke detectors may be powered by battery power. CCBC 310,912 & 310.9.1.31 B. Smoke detectors are required in each room used For steeping, centrally located in the wall or ceiling in corridors provideing access to each separate sleeping area, at each floor or basement level and in close proximity to the stairway, CCBC 310,9.141 C. Smoke detectors shall sound an alarm sudible in all area of the building or be Interconnected. ECBC 310.9.1.41 D, Where the ceiling height of a rood open to the hallway serving the bedrooms exceeds that of the hallway by 24 inches or more, detectors shall be installed in the hallway and near the high point of the adjoinging room. (Battery operated smoke detector permitted in existing construction only) F. Smoke detectors to be mounted and located 8 inches below telling height, (see legend) 4040 FILE ROOM 150 SQ, FT 107 FILE ROOM 140 SQ FT 106 9 HALLWAY A 183 SQ, FT (N) 0 108 FILE ROOM B. 171 SQ, FT 105 9 LJ BAT BATH 1 32 SQ, FT � � W/H 32 SQ, FT ATTIC 70.F 103 ACCESS 7 102 OFFICE SUPPLY ROOM 87 SQ. FT HALLWAY C 1 04 �B' 58 SQ. FT ®B � 101 I (N) Ewe OFFICE 230 SO, FT 109 LEGEND SURFACED MOUNTED SMOKE DETECTOR ON CEILING BATTERY OPERATED B SURFACED MOUNTED SMOKE DETECTOR ON CEILING HARD WIRED OPERATED W. EXHAUST FAN FOR BATHROOM WEATHER PROOF FLOOD LAMPS ® FLOURESCENT LIGHTING FIXTURE \01, INHOUSE LIGHTING FIXTURE CE G.F.I. 110 VOLT OUTLET G.F.I. CIE 110 VOLT OUTLET 0-- QUADRAPLEX 110 VOLT OUTLET (:�E 240 VOLT OUTLET FOR DRYER G.F.I, D (N) (?�B, OFFICE AREA 368 SQ, ET 100B (N) o ) ®B. WAITING AREA 635 SQ, FT (N) 100 (N) A (N) PROPOSED ELECTRICAL FLOOR PLAN (N) o MASTER PANEL A 0 oTELEPHONE LOCATION (LIGHTING) OVERHEAD RUN WITH 3 WIRES © OUTLET CABLE T.V. HOME RUN TO EXISTING ELECTRICAL PANEL/BREAKER ASSIGNED TO EXISTING AREA FLOOR PLAN PWP 110 VOLT WEATHER PROOF OUTLET G,FJ. S SINGLE THROW TOGGLE SWITCH O JUNCTION BOX S3 THREE WAY TOGGLE SWITCH (E) EXISTING (N) NEW 15 AMP BREAKER X'S SOY VOLTS = 12 12 x 120 VA = 1,440 VA COMMONLY HOUSE ITEMS REFRIGERATOR APPROX. VA'S 1,500 VOLTAGE 120 PHASE Single A/C 6,000 240 Single LAUNDRY 1,500 120 Single 20 AMP BREAKER X'S 80Y VOLTS = 16 16 x 120 VA = 1,920 VA AIR BLOWER 800 120 Single DISPOSAL 1,000 120 Single DRYER/GAS 1,500 120 Single 30 AMP BREAKER X'S 80% VOLTS = 24 24 x 120 VA = 2,880 VA GARAGE DOOR OPENER 1,000 120 Single ATTIC FAN 1,000 120 Single EXHAUST FAN 1,000 120 Single LIGHTS ARE APPROX. 100 WATTS (EA.) RECEPTACLES = 160 VA ELECTRIC OVEN 10,000 240 Single ELECTRIC WATER HEATER 6,000 240 Single ELECTRIC HEATING UNIT 20,000 240 Sin le 10 OUTLETS 180 VA'S PER OUTLET = 1,800 WATTS WHICH IS 80% ❑F BREAKER ALLOWED, (SAMPLES ONLY) MASTER PANEL A O (N) (N) 0 (N) (N) 0 (N) 0 ROVIDE 6" SQ. YMBOL OF ECAL ON EXT. ACE OF GLASS. DOOR NOTES: 1.ONLY ONE (1) RIM CYLINDER AND CYLINDER GUARD WILL BE TEMP. \ FURNISHED FOR REAR ENTRY DOOR. LOCATION TO BE DETERMINED \----DOOR SCOPE IN FIELD BY CONSTRUCTION PROJECT MANAGER. (OPTIONAL) 2. ALL DOOR CLOSURES ARE TO BE ADJUSTED TO COMPLY \ WITH THE FOLLOWING REQUIREMENTS: A. MAXIMUM EFFORT TO OPERTATE DOORS (PUSH/PULL) SHALL NOT EXCEED 8 1/2 POUNDS FOR EXTERIOR z0 DOORS AND 5 POUNDS FOR INTERIOR. O m B. SWEEP PERIOD OF DOORS FROM AN OPEN POSITION / OF 70 DEGREES SHALL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3' FROM THE LATCH, 0 KICK PLATE MEASURED TO THE LEADING EDGE OF THE DOOR. ELATCHSIDE HARDWARE EXTERIOR EXTERIOR DOOR DOOR LOCATIONS FOR WOOD DOORS (A) (B) EXTERIOR DOORS CENTER T^I 42" — CENTERLINE OF 12" X3" PUiSH — 53' SCHED. CENTERLINE OF PULL — 34" 6" KEY CYLINDER IS IN TOP OF 15' X 3 1/2" PLATE (USE TOP CYLINDER OF PANIC HARWARE. OOR rR vE"BuLE D l<7 FJ CENTERLINE OF PULL — 40' 69dfER1IE OF (3) BAi2'S 39',42', & 45" TEMPERED CENTERLINE OF 12" X3" PUSH — 53" GLASS I RESTROOM DOORS: CENTERLINE OF PULL — 40' CENTERLINE OF PUSH — 50" o I SCHLAGE BRAND AL —SERIES KICK PLATE AL10S PASSAGE LATCH Both lever always unlocked INTERIOR INTERIOR DOOR DOOR (C) (D) 0 SCHED. SCHLAGE BRAND AL —SERIES AL40S BATH/BEDROOM PRIVACY LOCK Push—button locking, Can be M open from outside with small screwdriver. Turning inside lever PUSH/PULL PLATE or closing door releases button. 3" X 12" z_ z SCHLAGE BRAND AL —SERIES O 5� AL170 SINGLE DUMMY TRIM Single dummy trim for one O side of door. Used for door 0 pull or as matching inactive trim. BATH 1 18" KICK PLATE DOOR (E) NOT TO SCALE DOOR STYLES [0-2 1 /2" 2 1 /4" AT 1:2 COMPRESSED CARPET 1 MAX, SLOPE 1/4" MAX. BELOW THRESHOLD FINISH FLOOR EVEN THRESHOLD MERCER PROCDUCTS CO. #940 \FPINLESS TD. EDGE "T" SNAP -IN BLACK UBBER MOLDING WITH #980 CARPET METAL TRACK QUARRY OR PAVER TILE II illllllll IIIII I IIIII I ' SET ALUMN. TRACK FLUSH FLOORSTONE TAPER MIN. 12" WITH TOP OF TILE 1124B.2 Changes in Level. Changes in level up to 1/4 inch 1/4" MAX 6mm) vertical and without edge treatment see Figure 11B-5E c)and(d). Changes in level between 1/4 inch (6mm) and 1/2 inch 12.7 mm) shall be accomplished by means of a romp that complies with Figure 11B-5E (d). IN LEM 2 CD I CD 0 CU DOOR SCHEDULE DOOR FRAME DETAILS 3 REMARKS MARK SIZE TYPE MAT'L FIN TYPE MAT'L FIN HEAD JAMB Ca L.I _ rn SINGLE DOOR ENTRY/EXIT (D 3'-0' X 61-8' .C.V.R PAINT WOOD PAINT WOOD WOOD HANDICAP ACESSIBLE HARDWARE MOUNTED O2'-8' X 6'-8' ,C.V.D. PAINT WOOD PAINT WOOD WOOD DOUBLE DOOR EGRESS O3 2'-8' X 6'-8' .C,V.D. PAINT WOOD PAINT WOOD WOOD 0 2'-8' X 6'-8' .C.V.➢. PAINT WOOD PAINT WOOD WOOD OS 2-8' X 6-8' .C.V.D. PAINT WOOD PAINT WOOD WOOD 6O 2'-8' X 6'-8' .C.111. PAINT WOOD PAINT WOOD WOOD O3'-0' X 6'-8' .C.V.D. PAINT WOOD PAINT WOOD WOOD HANDICAP ACESSIBLE HARDWARE MOUNTED O3'-0' X 6'-8' .C.V.D. PAINT WOOD PAINT WOOD WOOD HANDICAP ACESSIBLE HARDWARE MOUNTED O2'-0' X 6'-8' .C.V.➢. PAINT WOOD PAINT WOOD WOOD 10 3'-0' X 6'-8' C.V.D. PAINT WOOD PAINT WOOD WOOD �* DOUBLE DOOR TEMP GLASS ENTRY/EXIT HANDICAP ACESSIBLE HARDWARE MOUNTED 11 12 13 14 15 16 HARDWARE NOTES - I. ALL SOLID CORE DOORS TO HAVE 1-1/2 PAIRS BALL BEARING HINGES. CONSULT OWNER FOR DESIRED HARDWARE FINISH. 2. CONSULT OWNER FOR REQUIREMENTS OF WHICH DOORS ARE REQUIRED TO HAVE LOCKSETS, AND WHICH DOORS ARE REQUIRED TO HAVE LATCHSETS. 3. xx SIGN 'THIS DOOR MUST REMAIN UNLOCKED DURING DURING BUSINESS HOURS' LEGEND, S.C.W.D. = SOLID CORE WOOD DOOR H.C.V.D. = HOLLOW CORE VINYLE DOOR 40'-6" R 0 0 M F I N I S H S C H E D U L E KEY FLOOR BASE WALLS CEILING STYLE (� XXXXX w a U w �_ K a V u V w usi > > a U a a 3 � q r, o m w vJ _ � = r � a w U ¢ U w a i J w o N o _ ROOM NUMBER LD. I00A WAITING AREA X X X X 9'-6" SUSPENDED CEILING 100E OFFICE AREA X X X X W-6" SUSPENDED CEILING 101 HALLWAY C X V-6" SUSPENDED CEILING 102 BATH 1 X X X X x 103 BATH 2 X X x X X 8'-O" 104 OFFICE SUPPLY ROOM X 7'-6" 105 FILE ROOM X V-0" SUSPENDED CEILING 106 FILE ROOM X 9'-6" SUSPENDED CEIUNG 107 FILE ROOM X 9.-0" SUSPENDED CEIUNG 108 HALLWAY A X 9'-0" 109 109 X 9'-0. SUSPENDED CEUNG 110 REMOVED 111 REMOVED 112 REMOVED 113 REMOVED 114 REMOVED 115 REMOVED 116 REMOVED 13'-8' 5'-51, 19'-9" 4040 0 1 0 NOTE 3 C HARDWARE (B) A FILE ROOM 150 SQ, ET 107 1 i O O I FILE ROOM 140 SQ FT HALLWAY A 183 SQ, FT 106 108 0 FILE ROOM 171 SQ, FT 105 �11 0 (E) C BAT &BATH32 SQ, FT 1 �W/H SQ, FT ATTIo 104 ACCESS 7 SQ. FT 103 102 9 OFFICE SUPPLY ROOM 87 SQ, FT HALLWAY C 104 58 SQ. FT 101 I 1 9'- 7" j 9'-10" 4040 OFFICE 230 SQ, ET 109 3 CO F- 0 z A S-1 01 OFFICE ARFpA 368 SO, ET 1 008 4 i 0 05 08 0 0 #8 WOOD SCREWS 3/2, X 3" 4'-0" DIVIDER WALL FASTEN TO WALL (D) O7 FASTEN W/ 1/4' 2 16" O,C' REDHEAD ANCHORS 1124B.3 Carpet If carpet or carpet file is used on a ground or 1 floor surface, then it shall be securely attached: have a firm cush— ion, pad or backing or no cushin or pad: and have a level loop, 1/4- TO 1/240,_6„ textured loop: level —cut pile, or level—cut/uncut pile texture. The f / maximum pile height shall be 1/2 inch (12.7 mm). Exposed edges of = 4 FT, HIGH PARTITION DIVIDER carpet shall be fastened to floor surfaces and have trim along the Tot CHMM M LEVEL entire length of the exposed edge. Carpet edge trim shall comply - EXISTING N ❑ N BEARING WALL PARTITIONS with Section 1124B.2. NOT TO SCALE FLOOR VARIOUS STYLES �i = EXISTING EXTERIOR MASONRY WALLS i CD REV. A 02 22 04 REV. B 02 26 04 REV. C 02/02/05 REV. D 02/08/05 Ln In oo Q0 i_ 00 0) 07 Q0 co N II L` / I i-- I 4 Arnrno In ��--� V � V 0 CD LLJ O 07 LLJ LLJ m z m In � z LLJ `0 z m O z _j m i O Q x O Q Q z z_ m Q 1D w T z _jU LLJ = Q . Q LLJ O Q a- (f) U > CE_ ■■ z 5 a cc O O J LAI H O IL O cc IL J W W 2 32' O.C, STAGGARED O m (_0 O O O — 4'-4° 15'-0" m N 0-) >, cn Q o � L U Lii E] — Q WAITING AREA w 0) w _j Q I-, 267 SQ, FT m E 100 a - U S o � � N O � U Q —Drq (n D_\17 aPROJECT NO. COMMENCED NOTE 3 Dece r 30, 00 HARDWARE 10 (A) — PHIL ROBLES z REVISIONS DATE / OCCUPANCY LOAD SYMBOL REV. D 02/08/05 I � � 13'-2" NOTES. SCALE 1/4" = 1 FT 1. THE USE AND OCCUPANCY LOAD OF EACH ROOM AND/OR AREA, RELATE EACH USE TO A CDC TABLE 10-A ITEM. NOTE OCCUPANT LOADS WHICH ARE THE GREATER NUMBER A-2a.DWG BASED ON THE CBC TABLE 10-A OR THE ACTURAL NUMBER O ii 02/08/05 PROPOSED FLOOR PLAN:ffj jiq7mq46O1 Am2 DATE Lo In 00 CD (D r- 00 M m CD tD N I I I i — — — — rr) (D Ln o __ -------------__ r� D� ! - - - - - - - - - - - - - - - - - - - - - - - - - - _- - V W 0 Cj) Ch m Ld EXISTING STUCCO --f� z m rn ZLLJ m J � Oz z m F=- x Q Q z O Q O J Z m Q — � W U Lij C� Q O O 4040 4.040 BACK EXIT 40'-6" F04 NORTH ELEV. VIEW: Fo 1 (E) SIGNAGE (E) ROOF TOP WITH 90 LB ROLL ASPHALT w _ — — — — — — — — — o [fill 1 1 -4- -+- t--_ BAIL BONDS I IT- 11111111 Ili] Jill It I I I I 321- 11 3 FRONT ENTRANCE > 40'-6" z 1 05 SOUTH ELEV. VIEW: F02 J W t� NORTH> P Z 2X12 EXTERI❑R WOOD DESIGN 2X8 EXTERI❑R WOOD DESIGN (2 PLCS,) TOP & BOTTOM C4 PLCS.) x w W 0 cn i m EXISTING STUCCO ]SOONDS • EXISTING STUCCO i 0 C O m Q0 O _ 00 m N c)) � I c1 _ Q d Q L U Ln X o L W c Q Q) E 0 p E C O O O N N O-c U Q --D r'-) Un m PROJECT NO. COMMENCED Dece er Q, PHIL ROBLES REVISIONS DATE 40'-6" SCALE 1 /4" = 1 FT A-3.DWG 01 /10 /04 06 EAST ELEV. VIEW: A03 0 NOTES: 1, LIGHT & VENTILATION PER CBC SECTION 1202, MINIMUM OF 15 CFM OF OUTSIDE AIR PER OCCUPANT IS REQUIRED FOR VENTILATION, Ay 8 INCH DIA, AIR TRANFER rrr FII_I 4 WAY AIR TRANFER LLL L� AIR INTAKE rrr /0 INCANDESCENT LAMP FIXTURE 2 TUBE FLORESCENT LIGHT FIXTURE 4 TUBE FLORESCENT LIGHT FIXTURE LEGEND (EXISTING CEILING MATERIAL SURFACED) 1A. EXISTING 1/2' DRYWALL 9'-0" HIGH CEILING 2B, EXISTING SUSPENDED 9'-0' CEILING HIGH 3C, EXISTING SUSPENDED 8'-0' CEILING HIGH 4D, _ otf O O � Z 4040 1 4040 #10 GA. VERTICAL HANGER WIRE @ 4'-0' ALONG EA. MAIN RUNNER 45` SPLAY WIRE BRACING IN PLANE OF MAIN RUNNER. ALL WIRES ATTACHED TO MAIN RUNNER, 4 DIRECTION MAX, \- SPLICE \\ \\ 3 TURNS MIN. IN 1 1/2' TYP. MAIN RUNNER @ 4'-0' O.C, TYP, SPLAY BRACING DETAIL SUSPENDED CEILING SYSTEM INSTALL COMPRESSION STRUT 8'-0' O.C. EA. DIRECTION OR 64 SF, OF CEILING AREA PER UBC S SEISMIC LOCKING CROSS RUNNER @ 2'-0' O.C, HILTI CEILING CLIP ASSEMBLEY PER ICBO ER - 5457 —, SPLAY HANGER WIRE @ 4'-0° O.C. BRACE MAX. WIRE LATERAL FORCE BRACING NOT EXCEED WITH D.C. IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 4' FROM EA. WALL RUNNER 1 � �� MAIN RUNNER - PANEL— CONT. HORIZ. STRUT TO PREVENT SPREADING OF RUNNERS SUSPENDED CEILING DETAIL AT WALL =R WIRE CROSS RUNNER 4040 NOTE: 1, METAL SUSPENSION SYSTEMS TO BE USG INTERIORS, INC TYPE DXL 1 HR RATED PER UL DESIGN L 202 2. METAL SUSPENSIl7N SYSTEMS FOR ACOUSTIAL TILE AND FOR LAY IN PANEL CEILINGS SHALL BE INSTALLED IN ACCORDANCE WITH UBC 25-A AND 16-0 3, HANGERS FOR SUSPENDED CEILINGS SHALL BE NOT LESS THAN THE SIZES SET FORTH IN TABLE NO 25-A, FASTENED TO OR EMBEDDED IN THE STRUCTURAL FRAMING, MASONRY OR CONC, 4, HANGERS TO BE SADDLE -TIED AROUND MAIN RUNNERS TO DEVELOPE THE FULL STRENGTH OF THE HANGERS LOWER ENDS OF FLAT HANGERS SHALL BE BOLTED TO RUNNER CHANNELS OR BENT TIGHTLY AROUND RUNNERS AND BOLTED TO THE MAIN PART OF THE HANGER, 5, LOCKING CLIP TO FASTEN CROSS RUNNER TO MAIN RUNNER SPLICES AND INTERSECTIONS OF RUNNERS SHALL BE ATTACHED WITH MECHANICAL INTERLOCKING CONNECTORS SUCH AS POP RIVETS, SCREWS, PINS, PLATES WITH BENT TABS. OR OTHER APPROVED CONNECTORS DESIGN CONNECTORS FOR 2 X DESIGN LOAD OR ULTIMATE AXIAL, TENSION OR COMPRESSION MIN. 60 POUNDS, 6, ALL CROSS FURRING SHALL BE SECURELY ATTACHED TO THE MAIN RUNNER BY SADDLE TYING WITH NOT LESS THAN ONE STRAND OF NO, 16 OR TWO STRANDS OF NO, 18 U,S. CAUGE TIE WIRE OR APPROVED EQUIVALENT ATTACHMENTS. 7. RUNNERS AND FURRING. THE MAIN RUNNER AND CROSS-FLURRING SHALL BE NOT LESS THAN THE SIZES SET FORTH IN TABLE NO. 25-A EXCEPT THAT OTHER STEEL SECTIONS OF EQUIVALENT STRENGTH MAY BE SUBSTITUTED FOR THOSE SET FORTH IN THIS TABLE 8, HANGER ALLOW TENSION #12 170 LB, #11 225 LB. #10 300 LB, SUSPENDED CEILING DETAIL 4040 0 2 rrr rrr STORAGE OFFICE 0 -I L 5 IY z 150 SQ. FT 230 SQ, FT L1L 107 � 109 rrr NOTE 2B NOTE 2B ILL rrr NOTE 3C STORAGE Ll 140 SO, FT HALL AY A \0/ 183 Q. FT R r � /113 1 NOTE lA rOy 106 08 108 NOTE 1A Lj 110 NOTE 1A NOTE 2B ,O /0 114 NOTE 1A rrr r t �1�y yyL®y Sys STORAGE LLL NOTE 1A rrr rrr 171 SQ, FT NOTE 1A NOTE 2B �Oy 112 y NOTE 3C 115 105 105 111 \0/ C NOTE 1A BAT —� 32 SQ, FT BATH 1 �� /0 R r a I ATTIC I 104 W/H 103 32 SQ, FT ATTIC I 04 W/H 03 Oy NOTE 1A ] 6 / I ACCESS 7 Q, FT 102 i ACCESS 02 I— � L NOTE 1A NOTE 1A 100 STORAGE ROOM 116 87 SQ, FT HALLWAY C 1 041 58 SQ,. FT 104 101 NOTE lA NOTE lA i a61N -FICT ARE 308 ET I REV. A 1 02 24 04 REV. B 02/02/05 REV. C 02 /08 /05 In Ln 00 19 (D I-- 00 O7 07 CO CO CV I to I i- I -1- � (D Ln I I I r- r- Qo 0 Lv ~ � mm LJ Lj m J m � Z Ln C) z m z J O z m 1— X Q Q < z_ m Q D w Ld _ — c( < O z 0 O] a_ : IZ In U a- Z z J W W rm U W J LI. W W y 0 L 0 cc L a Z H W ddJ rrr �Ta � O m Q0 O 00 0 I� m CN 0-)V) >,� Q d N Ln Q Q) I O x t o d LIJ 0 c t\ Q E Q) +✓ c c O O a N N C7 J~ C) <C -D r-) (n LL WAITING AREA PROJECT NO. 635 SQ, FT COMMENCED DeceAm, 30, 2 1, - 1001 PHIL ROBLES T I- REVISIONS DATE OREV. C 02/08/05 Y y CALE 1 /4" = 1 FT /1 ) A-4,DWG 02 /08/05 EXISTING REFLECTIVE CEILING PLAN PROPOSED REFLECTIVE CEILING PLAN oil A•4 EXISTING VERTICAL WALL { PARTITION 4 FT. WALL #8 WOOD SCREWS 3/8" X 3" FASTEN TO VERTICAL WALL EXISTING D.F. 2X6 BALLON /�\ PARTITION GUTTED SEC. /� NOT TO SCALE NEW 4 FT. PARTITION NOT TO SCALE EXISTING WALL T (N) 4 FT® PARTITION S @ 16" O.C. RD. BOTH SIDES P.T. 2X4 6 d- 1 /4" 0 STAGGARE 1 /2" GYF (E) BEARING WALL 2X4 TOP PLATE \ (E) 2X12 LEDGER BRD. BOLT D BOTH ENDS (E) 2X12'S @ 2FT. ❑.C, (E) LEDGER BRD, C2 PLCSJ i� (E) ACCOUTICAL CEILING (E) ACCOUTICAL CEILING 0 I (E) BEARING WALL KLVIJI� REV. A (E) 2 FT, PARAPET REV. B (E) 8 INCH BRICK WALL. p. a .a 40'-6° EXISITNG NORTH ELEV. VIEW: 01 (E) 2X12'S ROOF RAFTERS @ 24" ❑fC 2- 10d NAILS (N) 2X4 D,F, BRACING @ 36" ❑JC, \_ (E) 1/2" GYP, BRD. 7 (N) 5/8" GYP, GREEN BRD, ONE SIDE O �I BATH 1 FLOOR LEVEL ATTIC SPACE 5- 16d NAILS 117 __ INSULATION (E) 1/2" GYP, BRD, (N) 2 X 4 D,F. @ 16" ❑,/C, /(N) 1/2" GYP. BRD, ONE SIDE 1 /4" 0 X 3" SHOT PINS @ 24" O.C. WAITING AREA EXISTING NON BEARING WALL S @ 16" O.C. RD. BOTH SIDES P.T. 2X4 FLOOR LEVEL 4 n Lo DO QO co r-1 CO CD N CQ Un > m � o LLJ O fl- m C w w w m m z v � z m Ln J _1 0 z m I= x Q Q z z m Q � � w J o C `L z _ Q w o Q :�i m c> > a - c- 0 m Q0 0 00 0 m N 07 07' I � >'C Q d v U Q I x - C) d d v 0 E o 3: a a� 0 4 c c 0 O N CV o _c U Q t4') (f) Q_ PROJECT NO. COMMENCED eceryo, 30, _200 PHIL ROBLES J REVISIONS DATE REV. B 02/08/05 Y_ SCALE 1 /4" = 1 FT S-LDWG 02/08/05 S-1 07 �ln — T TO SCALE MUD SILL DETAIL DATE REV. A 02/08/05 TITLE 24 ACCESS REQUIREMENTS (D Q0 r- XIII. LOCKERS 1. SITE DELVELOPMENT 00 rn M 1. Grade and develop site so that a primary building entrances are accessible to the 11. The cross -sloe on a ram or the sloe across a ram landing in an direction shall P P P P 9 Y 3. Every portion of every building in which are installed Beets, tables, merchandise, I'participants, 1. Where lockers ore provided for public, clients employees, ees members orN P P ll Y at least one and not less than one percent of all lockers shall be made accessible CSC CO � � h sical disabled from both the public way and from the special parking spaces(s) P Y� Y P Y P P 9 not exceed 1:50 sloe 2% gradient). P ( 9 ) equipment or similar materials shall be provided with aisles leading at an exit. to the physically disabled. A path of travel not less than �I rO co LO provided for the disabled. P 12. Handrails are required an ramps that provide disabled access if the slope exceeds 1 4. Every aisle shall be not less than 3 feet wide if serving only one side, and not 35 inches in clear with to shall be provided to these lockers. 0-) F_ foot rise in 20 feet of horizontal run. less than 3 feet 6 inches wide if serving both sides. Such minimum, width shall be XIV. SIGNAGE d II. PARKING measured at the point farthest from an exit, cross aisle or foyer and shall be increased by 1-1/2 inches for each 5 feet in length toward the exit, cross aisle or 1. Letters and number on signs shall have a width -to -height ration between 3:5 and 1:1 {� 1. Provide ( 1 ) disabled parking space 13. Handrails shall be placed on each side of each romp (except curb ramps). shall be continuous the full length of the romp, shall be 34 to 38 inches above the ramp foyer. With continental seating side aisle shall be not less than 44-inches in width. and a stroke- with - to -height ratio between 1:5 and 1:10. Q0 2. Each space shall be 17 feet wide and culined to provide a 9 foot parking area and surface, shall extend a minimum of 1 foot beyond the top and bottom of the ramp. 2. Characters and numbers on signs shall be sized according to the viewing distances g g 9 W O � (Y an 5 foot access aisle. and the ends shall be returned. VII. STAIRWAYS from which they are to be read. The minimum height is measured using an upper case W 14. Handrails projecting from a wall shah have a space of 1-1/2 inches between the wall 1. Stairways shall have handrails an each side, and every stairway required to be more X lower case characters are permitted. Minimum character height shall be 3 inches. � m J m � 3. Not Used and the handrail. than inches in width shall be provided with not less than ones intermediate 3. Letters and numbers shall be raised 1/32 inch, upper case, son serif or simple serif � U � ail handrail for each 88-inches of required width, Intermediate handrails shall be r type and shall be accompanied with Grade 2 Braille,. Raised characters shall be at Ln z m 4• The mininum length of each parking space shall be 18 feet, Verify with the local 15, The grip portion of the handrail shall be not less than 1-1/4 inches nor more than spaces approximately equal within the entire width of the stairway. least 5/8 inch (16 mm) high, but no higher than 2 inches (50 mm). Pictograms shall Z Cfl Q Z J building auithority. 1-1/2 inches in cross-sectionol dimension, or the shape shall provide an equalent 2. Handrails shall be 34 to 38 inches above the racing of the treads. be accompanied by the equivalent verbal description place directly below the picto- gram. The border dimension of the pictogram shall be 6 inches O Z � Q Q Z 5. Surface slopes of paring spaces for the physicaly, disabled shall not exceed surface and all surfaces shall be smooth with no spar corners. gripping P Q OX Q 1:50 slope (Z% gradient) in any direction. 16. The surface of ramps shall be slip resistant. 3. Handrails shall extend a minimum of 12-inches beyond the top nosing and 12-inches 4. The characters and background of signs shall be eggshell, or othe non -glare m � plus the tread width beyond the bottom casing. finish. Character and symbols shall contrast with their background - either light C0 -1 U Q O Z J O 6. When less than 5 parking spaces are provided, at buildings and facilities subject to 17. Where the ramp surface is not bounded 8y a well or fence, the ramp shall comply with chorcters on a dark background or dark character on a ligh background. Q W O Q 0 these regulations, one shall be 17 feet wide and lined to provide a 9 foot parking one of the folowing requiremnts. 4. Where the extension of the handrails in the direction of the stair run would create n < C) Q area and an 8 foot access aisle. However, there is no requirement that rthe space a hazard, the extension shall be made at right angles, on the face of returning 5. Where permanent identification is provided for room and spaces, signs shall be be reserved exclusively or identified for disabled use only. wall. Where the stairs are continious from landing to landing, the inner rail shall installed on the wall adjacent to the latch side of the door. Where there is no wall a. A guide curb a minimum of 2-inches in height shall be provided at each side of be continuous and need not extend out into the hallway. spaced to the latch side of the door, including of double leof doors, signs shall be 7. All parking structures and parking areas shall have disabled parking spaces and the rpm P. orplaced on the nearest adjacent wall. Mounting height shall be 60 inches (1525 mm) of entrances leading to disabled parking spaces and vehicle exits from disabled b. A wheel guide rail shall be provided centered 3-inches plus or ninum 1-inch 5. Ends shall be returned or shall terminate in newel posts or safety terminate. above finish floor to the centering of the sign, Mounting location for such signage parking spaces including the driveway, aisle and stall area, shall have a minimum above the surface of the ramp. shall be so that a person may approach within 3 inches 76 mm of signage without P Y PP ( ) vertical clearance of 9'-6". 6. Handrails projecting from a wall shall have a space of 1-1/2 inches between the wall encountering protuding objects or standing within the swing of a door. and the handrail. 6. On doorways leading to men s sanitary facilities, an equitaterai triangle 1/4 inch 8. The 9'-6" verticcal dimension shall be clear of all obstructions, including beams, V. CURB RAMPS thick with edges 12 inches long and a vertex pointing upward shall be provided and sprinkler heads, piping, etc. 7. The handgrip portion of handrails shall be not less than 1-1/4" inches nor more than on doorways reading to women's sanitary facilities. A circle 1/4 inch thick and 12 1. Curb ramps shall be constructed at each corner of street intersections where a 1-1/2 inches in cross -sectional dimension of the slope shall provide an equivalent inches in diameter shall be provided. These geometric symbols shall be centered on 9. A disabled parking space shall be located so as not to require its user to wheel a pedestrian way crosses a curb, and where disabled access is required from parking gripping surface and shall have a smooth surface with no sharp corners. the door of a height of 60 inches and their color and contrast shall be distincly walk behind any other disabled or non -disabled parking space. stalls. different from the color and contrast of the door. FO & All tread surfaces shall be slip -resistant. 1 10. Pedestrian ways which are accessible to the physically disabled shall be provided 2. Curb romps shall be minimum of 4 feet in width and shall lie generally, in a single 7. On doorways leading to unisex sanitary facilities, an equilateral triangle mounted from each disabled parking space to related facilities, including curb cuts or romps sloped plane. Cross slope shall not exceed 1:50 (2% gradient). 9. Treads shall have smooth rounded or chmfered exposed edges (1/2" radius min.), on a circle shall be provided. as needed. and no abrupt edges at the nosing (lower front edge). 3. The slope of curb ramps shall not exceed 1 vertical to 12 horizontal. The slope of XV. DRINKING FOUNTAINS 11. In each parking area, a bumper or curb shall be provided and located to prevent the land or floor side of curb ramps shall not excee 1 vertical to 10 horizontal. 10. Nosing shall not project more than 1-1/2 inch past the face of the riser below. encroachment of cars over the required width of walkways. 1. Where water fountains are provided, they shall comply with disabled access 4. A level landing 4 7feet deep minimum shall be provided of the upper end of each curb 11. Risers aholl be sufficiently solid to prevent the passage of objects large than 1/4 inch. requirements. 12. Physically disabled parking spaces shall be located as near as practical to an romp over its full width to permit safe egress from the ramp surface, or the slope of accessible entrances(s). the land or flared sides of the curb romp shall not exceed 1 vertical to 12 horizontal. 2. Water fountains shall be located completely within alcove or otherwise positioned as no! to entroach into pedestrian ways. The alcove in shich: the water fountain 13. When disabled parking is located such that the path of travel from the disabled 5. Curb ramps shall have detectable warnings the full length and width of the romp X. SANTARY FACILITIES (GENERAL) is located shall be not less than 30 inches in width nor more than 24 inches in parking space(s) to a building or facility requires a disabled person to travel into detectable warnings shall consist of raised truncated domes with a diamerter of depth. the public way, the enline path of travel, including that portion in the public way, norminal 0.9 inches (23 MM), a height of nominal 0.2 inches (5 MM), and a 1. When sanitary facilities are located an accessible floors at a building, they shall shall conform to all appplicable code requirements. center -to -center spacing of nominal 2.35 inches ( 60 MM) and shall contrast visually be made accessible to the physically disabled. 3. The drinking foundtain shall be minimum of 17 inches to 19 inches in depth and with adjoining surfaces, either light -on -dark, or dark -on -light. there shall be clear and unobstructed knee space under the drinking fountain not 14. When separate parking areas such as covered and uncovered areas, non- 2. Where seperate facilities are provided for non -disabled persons of each sex, less than 27 inches in height and 6 inches in depth, the depth measurement being interconnected parking areas or levels or separate parking areas or structures, VI. ENTRANCES seperate facilities shall be provided for disabled persons of each sex also. Where taken from the front edge of the fountain. Additionall, there shall be toe are provided on a site, each parking area shall have disabled parking stalls. unisex facilites are provided for non -disabled persons, such unixex facilities may clearance of 8 inches in height above the floor, and 17 inches in depth from the Each for the disabled be identified by a I. All primary entrances to buildings and facilites shall be made be provided for the disabled. front edge of the fountain. A side approach drinking fountain is acceptable. 15. parking space reserved shall permanently accessible to the physically disabled. a fixed reflectonized- sign constructed of porcelain on steel, beaded text, or equal, 3. All doorways leading to sanitary facilities shall have 32 inches clear unobstructed 4. The bubbler shall be activated by a control which is easily operated by a disabled displaying the International Symbol of Accessibility. The sign shall not be smaller than 2 All accessible entrances shall be identified with at least one standard sign and with openings. person such as a hand -operated lever type control. The bubbler orfice shall be locatedwithin 3 inches of the front of the drinking fountain and shall be within 9 70 square inches in area and shall be centered at the interior end of the parking space at a minmum height of 80-inches from the bottom of the sign to the parking space additional directional signs, as required, visible from approaching pediestrian ways. 36 inches of the floor. The water stream from the bubbler shall be substantial) Y finished grade, or centered on the wall at the interior end of the parking space at a 3. Every required entrance or passage doorway shall be of a size as to permit the XI. TOILET ROOM FIXTURES AND ACCESSORIES paralled to the front edge of the drinking fountain. minimum height of 80-inches from the parking space finished grade, ground, or sidewalk, installation of a door not less than 3 feet in width and not less than 6 feet, T. The height of accessible water closet shall be a minimum of 17 inches and a maximum 8-inches in height, doors shall be capable of opening of least 90 degrees and shall of 19 inches measured to the top of the toilet seat. XVI. TELEPHONES 16. A sign shall also be posted in conspicuous place, at each entrance to the be so mounted that the clear width of the doorway is not less than 32-inches. off-street parking facility, not less than 17 inches x 22 inches in size with 2. Provide 18 inches from the centerline of the water closet to the adjacent wall 1. If public telephone are provided, they shall comply with disabled access requirements. 02 lettering not less than 1 inch in height whit clearly and conspicuously states the 4. Where a pair of doors is utiliized at least one of the doors shall provide a clear finish. following: Unauthorized vechicles not dispolying distinguishing placards or license unobstructed opening width of 32-inches with the leaf positioned of an angle of 90 2, Provide a 30 inches x 48 inches clear space at telephone, The clear space may plates issued for physically diabled persons may be towed away at owner's expense. degrees from its closed position. 3. Toilet flush controls shall be openable with one hand, and shall not require tight Include knee space under the telephone. Towed vehicles may be reclaimed at grasping, pinching, or twisting of the wrist. Controls for the flush valves shall or 5. When an automatic door operator is utilized to operate a pair of doors, at least one be mounted on the wide side of the toilet areas, no more than 44 inches above the 3• The highest operable part of the telephone shall be within 48 inches of the floor if by telephoning of the doors shall provide a clear unobstructed opening with of 32-inches with the floor. The force required to activate controls shall be no greater than 5 pounds. forward approachecd and 54 inches if side approached. door positiond at an angle of 90 degrees from its closed position. 16. In addition to the above signage requirements, the surface of each parking place 4. Where urinals ore provided, at least one shall have a clear space 30 inches wide x 4. The cord from the telephone to the handset shall be at least 29 inches long. shall have a surface indentification duiplicating the symbol of accessibility 6. Latchingand locking doors that are hand titivated and which are in path of 9 P 48 inches long in front of the urinal. consisting of a white figure on a blue backgound, at least 3 foot square. travel, shall be operable with a single effort by lever type hardware, panic bars, 5. If banks of public telephones are provided, then a reasonable number, but always at push-pull activating bars, or other hardare designed to provide passage without 5. Flush controls shall be operable with one hand shall not require tight grasping, least one, in a building or facility shall be equipped with a volume control. Each parking space reserved for vans ahll be identified by a permanently affixed "VAN requirng the ability to gross the opening hardware. pinching or twisting of the wrist and shall be mounted no more than 44 inches above reflectionized sign ACCESSIBLE" mounted below the international symbol of theThe forced required to active controls shall be no greater than 5 pounds 6. Telephones shall have push-button controls where service for such equipment is available. accessibility, 7. Hand activated door opening hardware shall be centered between 30 & 44 inches P foot U) above the floor. XVII. CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS W III. WALKS AND SIDEWALKS 8. The floor or landing on each side of an entrance or passage door shall be level (not 6. A clear floor space 30 inches wide x 48 inches long shall be provided in front of a 1. The minimum clear floor or ground space required to accomodate a single, stationary to exceed 1:50 slope) and clear. The level and clear area shall have a length lavatory to allow a forward approach, such clear floor space shall adjoin or overlap wheelchair and occupant if 30 inches x 48 inches. The minimum clear floor or ground 1. Walks and sidewalks subject to these regulation shall have a continous common opposite the direction of door swing of 48 inches as measured at rigfht angles to the on accessible route and shall extend into knee and toe space underneath the lavatory 19 inches. space for wheelchairs may be positioned for forward or parallel approach to an object. Clear floor or ground space for wheelchairs may be part of the knee space O surface not interrupted by steps or by abrupt changes in level exceeding 1/2-inch plane of the door in its closed position. a maoximum of required under some objects. and shall be a minimum of 48-inches in width. 2. Surfaces with a slope of less than 6 percent grade shall be at least as 9. The width of the level and clear area on the side to which the door swings shall extend 24-inches past strike edge of the door for exterior decors and 18-inches past 7. Lavatories shall be mounted with a clearance of at least 29 inches from the floor to 2. One full unobstructed side of the clear floor or ground space for a sheelchair shall slip -resistant as that described as a medium salted fiinish. the strike edge for interior doors. the bottom of line apron with knee clearance under the front lip extending a minimum adjoin or overlap an accessible route or adjoin another wheelchair clear floor J P J of 30 inches in wdth with 8 inches minimum depth at the top. space, if a clear floor space is located in an alcove or other wide confined on all 3. Surfaces with a slope of 6 percent gradient or treater shall be slip -resistant. resistant. P P 9 P- 10. The floor or landing shall be not more than 1/2-inch lower than the threshold of the g. A projection of a lavatory bowl into the 8-inch clear space, they by reducing the or apart of three sides, addtional manurvering clearance shall be provided. W 4. When the slope in the directiion of travel of any walk exceeds 1 vertical to 20 doorway. Change in level between 1/4-inch and 1/2-inch shall be beveled with a clear height below the lavatory to no less than 27 inches of 6 inches back from the 3. Provide an additional 12-inch width on one side for Alcoves greater than 15 inches horizontal (5% gradient) it shall comply with the provisions for pedestrian ramps. slope no greater than 1:2. apron meets the requjirements for providing knee clearance. A maximum height of 34 deep and designed for side approach. Z inches to the top of the lavatory is recommended. 11. The space between two consecutive door openings in vestibule, serving other than a 4. Provide an additional 6 inches width on one side for alcoves greater that 24 inches 5. Surfaced cross slopes shall not exceed 1:50 slope (2% gradient). required exit stairway shall providee a minimum of 48-inches of clear space from any g. Hot water and drain pipes under lavatories shall be insulated or other wise covered. deep and designed for frontal approach. door opening into such vestibule with the door is positioned at an angle of 90 there shall be no sharp or abrasive surfaces under lavatories. 6. Walks, sidewalks and pedestrian ways shall be free of gratings whenever possible. degrees from its closed position. Doors in series shall swing either in the some S. If the clear floor space only aloows forward approach to an object, the maximum high for gratings located in the surface of any of hese areas, grid openings in gratings shall be limited to 1/2-inch in the direction of traffic flow. direction or away from the space between the doors. 10. Faucet controls and operating mechanisms shall be operable with one hand and forward reach allowed shall be 48 inches. If the high forward reach is over on 12. Maximum effort to operate doors shall not exceed 5 lbs. for interior doors, 8 1 /2 not require right grasping, pinching or twisting of the wrist. The force required q g g P g• P g g q obstruction, the horizontal dimension of the obstruction shall be less than 7. Abrupt changes in level elan an accessible route shall not exceed 1/2-inch. When P 9 9 Y / lbs. for exterior doors, such pull or push effort being applied of right angles to to activate controls shall be no greater than 5 lbs. lever -operated, push -type and 25 inches. The maximum high forward reach allowed shall be 44 inches when the changes in level do occur, they shall be beveled with slope no greater than 1:2 hinged doors and at the center plane of sliding or folding doors. Compensating electronically controlled mechanisms are examples of acceptable designs. self -closing vovles ore allowed if the facuet remains open for at least 10 seconds horizontal dimension of the obstruction is between 20 inches and 25 inches. except that level changes not exceeding 1/4-inch may be vertical. devices or automatic door operators may be utilized to meet the above standards, 6. If the clear floor space allows parallel approach by a person in a wheelchair, the S. When changes in levels greater than 1/2-inch are necessary they shall comply with increased not to exceed 15 lbs. 11. Mirrors shall be mounted with the bottom edge not more than 38-inches from the floor. maximum high side reach allowed shall be 54 inches and the low side reach shall be - - -- the requirements for romps. Per CABO % ANSI A117.1-1992 no less than 9 inches above the floor. Side reach is allowed over an obstruction 13. Where turnstrikes are utilized in o facility for the purpose of provideing fully 12. Locate towel, sanitary napkin, and waste receptacles with all operable ports not provided the horizontal dimension of the obstruction does not exceed 24 inches. p F03 � 9. Walks shall be provided within a level area (less than 1:50 slope in any direction) controlled access, a door or gate that is accessible to the physically disabled, not less than 60-inches x 60-inches at a door or gate that swings toward the walk, shall be provide adocent to or within a distance not to exceed 30 feet from each more than 40-inches from the floor. �O and not less than 36-inches wide by 48-inches deep at a door or gate that swings turn still exit or entrance. CD O away from the walk, such walks shall extend 24-inches to the side of the strike edge 13. Locate toilet tissue dispensers on the wall within 12-inches of the front edge of •- - 0 O of a door or gate that swings toward the walk. 14. The bottom 10 inches of all doors except automatic and sliding shall have a smooth the toilet seat. m N O_ uninterrupted surface to allow the door to be opened by a wheelchair footrest XVIV. EXISTING BUILDING 0 10, All walks with continous gradients shall have level areas at least 5 feet in without creating a trap or hazardous condition. Where narrow frame doors are U) U) Q length at intervals of at least every 400 feet. used, a 10-inch high smooth panel shall be installed on the push side of the door, which will allow the door to be opened by a wheelchair footrest withou creating a 6. When an additon or alteration or change of occupancy or use, or an increase in , , C Q) U trap or hazardous condition. occupant load within on existing building occurs, full compliance incorporates the • - Q O IV. RAMPS following: p X -C O d 0'' 1. Any path of travel shall be considered a romp if its slope is greater than 1 foot 15. A narrow frame with a beveled top edge (30 degrees maximum bevel to vertical XIL GRAB BARS a. The addition, or areas of alteration, change of occupancy or use, or increase in 9 P Y _ C :3 Q f\ 0 W C O rise in 20 feet of horizontal run. plane) installed at the bottom of a gloss door (with no side frames) may be used 1. Grab bars shall be located on each side, or one side and the back of the physically occupant load shall fully comply. •- O � N E O 2• Not in lieu of providing the required 10-inch uninterrupted surface at the bottom of disabled toilet stall or compartment and shall be securely attached 33 inches above b. A path of travel from outside the buidling, from either the public way or the C E O used the door. and parallel to the floor. If a tank type toilet is used which obstructs the placement disabled parking spaces(s) leading to the subject area must fully comply. p v- N � � of the grab bar(s) 33 inches, the grab bar may be as high as 36 inches. C. The sanitary facilities drinking fountain and pulblic telephone in closest O _ O U Q N (0 3. Pedestrian romps seving primary entrance to buildings shall be a minimum 48-inches proximity to and serving th suject area, must fully comply. PROJECT NO. clear width but not less than the width required for exits. q 2. Grab bars of the side shall be of least 42 inches long with the rear end positioned 12 4. Pedestrian ramps serving primary entrance to buildings having an occupant load of VI 1. FLOORS AND LEVELS inches max. from the rear wall with the front end of the grab bar projecting 24" inches min. from the front face of the toilet, and grab bars of the back shall be not less than 2. Remodeled buildings that provide specific sanitary facilities for public use shall 9 P P Y 300 or more shall have minimum clear width of 60-inches. 1. In buildings and facilities, floors of a given story shall be a common level 36 inches long. have this information posted in the buidling lobby. COMMENCED 5. The maximum slope of a ram that serves an exitwa provides handicap access or is P P Y Y� P P throughout, or shall be connectged by pedestrian romps, passenger elevators or 3. The diameter or width of the griping surfaces of a grab bar shall be from 1-1/4 XX. ADDITIONAL REQUIREMENTS Dece er 10, 2003 in the path of travel shall be 1 foot rise in 12 feet of horizontal run. P special access lifts. inches to 1-1/2 inches or the shape shall provide an equivalent gripping surface. 1. The center of receptacle outlets shall be not less than 15 inches above the floor or �~ 6. Ram landings shall be provided at the to and bottom of each ram P 9 P P P 2. Floor surfaces shall be slip -resistant. 4• If the grab bars ore mounted adjacent to a wall, the space between the wall and the working platform. � grab bars shall be 1-1/2 inches. 2. The center of the grip of the operating handle of switched intended to be used by z PHIL ROBLES REVISIONS DATE 7• Intermediate landings shall be provided at interval not exceeding 30-inches of VIII. CORRIDORS AND AISLES the occupant of the room or area to control lighting and receptacle outlets, vertical rise and of each change of direction. Landings are not considered in horizontal distance 5• A grab bar and an wall or their surface adjacent to it shall be free of an shay 9 Y J Y P appliances, or cooling, heatin and ventilating equipment, shall be not less than 3 PP g' 9 9REV. A 02 08 05 / / determiningthe maximum of each ram P 1. Every corridor serving an occupant load of 10 or more shall be not less in width or abrasive elements. feet nor more than 4 feet above the floor or working platform. " SCALE 1 �4 = 1 FT 8. All landing widths shall be not less than the ramp leading to it and shall have a length than 44-inches. 6. Grab bars shall not rotate within their fitting. 3. The International Symbol of Accessibility shall be the standard used to identify of not less than 60-inches in the direction of the romp run. 2. Corridors that exceed 200 ft. in length shall: ficilities that are accessible to and usable by physically disabled person as set: 9. The width the landing shall extend 24-inches past the strike edge of any door or a. Corridors that exceed 200 ft. in length shall: 7. Edges shall have a minimum radius of 1/8-inch. forth in those buildingstandards. gate for exterior ramps and 18-inches past the strike edge for interior ramps: t b. Have, at a central location, a 60-inch x 60-inch minimum wheelchair turning space or passing above or, P P 9 8. Grab bars, tub and shower seats, fasteners and mounting devices shall be designed 9 9 4. If emergency warning s stms are required the shall activate a means of ornin the 9 Y 9 Y q Y 9 ADA-1,DWG 10. Intermediate landings at a change of direction in excess of 30 degrees an bottom c. Have at a central location, an intervening across or tee corridor, a minimum of 36 inches in witdth, or for 250 lbs. per linear foot load. hearing impaired. Flashing visual warning shall have a frequuency of not more than 60 flashes per minute. 02�08�05 landings shall be a minimum of 60-inches x 60-inches. d. Have, at a central location, an operable door. i ®5 - -- 04 3'-0" SI 1 REV. B 1 02/08/05 1 im NOTES: 1. 70 SQ. INCH ACCESSIBILITY SIGN PER SEC. 1129B.5 TO BE MOUNTED ON WALL 3 FT. FROM GROUND LEVEL, (17"x22") 2, SLOPE OF ACCESSIBLE PARKING AND LOADING AND UNLOADING AREA TO BE LESS THAN OR EQUAL TO 2 % IN ANY DIRECTION, 3, TYPICAL PAVEMENT SYMBOL PER SEC. 1129B.5 SURFACE IDENIFICA HANDICAPPED STALLS: 1) PROVIDE A MINIMUM OF HANDICAPPED MARED PARKING STALLS AS FOLLOWS: TOTAL PARKING HANDICAPPED STALLS 1 - 40 1 41 - 80 2 81 - 120 3 121 - 160 4 161 - 300 5 301 - 400 6 401 - 500 7 OVER 500 1/200 SEE SHEET A-2 FOR HARDWARE AND DOOR SCHEDULE 07 1 DOOR CONSTRUCTION RAMP UP WITH 7% TO 7.5% SLOPE EXAMPLE ONLY NOTE 1 HANDICAPPED PARKING SIGNS z 0 co _z cc LO In 00 Q0 Q0 � BACK GROUND I 00 M 0-) cD co N `n I`*`) CD LO M r_ O I WHITE SYMBOL a CO 0 w � m J W m m :�i z '-a c )LO z Z(_0Q D z m NOTE: SIGN ON PAVEMENT OF PARKING z � _J Q Z z SPACE, VERIFY DESIGN W/ LOCAL AUTHORITY Q 0 Q = z m < wm Lj Q o z _ Cf) N BOTTOM RAIL �_ a- can U OVIDE KICK PLATE (A) PROPORTIONS INTERNATIONAL SYMBOL OF ACCESSIBILITY r ;-------------, I I I I I 1 I i PULL SIDE 24" MIN. � CLEAR AT j� i EXTERIOR DOORS I I I I I I L I AT )R DOORS i I I I I I I I I I I I e PROVIDE THIS I I ADDITIONAL SPACE ' IF DOOR IS EQUIPPED I I WITH BOTH A LATCH 12 AND A CLOSER PUS SIDE MIN. I I 1 I I I L------------------------J FRONT APPROACH 11 gI a � � We 61 PAINTED ACCESSIBLE SYMBOL AT PARKING STALL o ACCESSIBLITY SYMBOL x —70 SQ. IN. 1 /4" STEEL ANDICAPPED PARKING PLATE PER CBC 3107 VAN ACCESSIBLE "Unauthorized vechicles parked in designated PROVIDE ADDTIONAL accessible spaces not SIGN BELOW SYMBOL displaying distinguishing OF ACCESIBILITY SIGN placards or license plates AT VAN ACCESSIBLE issued for persons with SPACES — SEE SITE CD dissabilites may be towed PLAN FOR LOCATIONS) away at owner's expense. Towed vehicles may be CD reclaimed at or 0O by telephoning " �— 1 1 /2" x 1 1 /2" TUBE STEEL FRAME — WELD ALL JOINTS CAP ALL I'° _ \ _ ,• ., I•°•, ENDS SHOP PRIME a•i i of \\\ /// \\\ /// \\\ /// ia•i AND FIELD PAINT 00 00 I4•I I�•I\ �/\ //\ �/I�•I I�•I I. L-J• I I. 12" 12" TRAFFIC ENTRY SIGN HANDICAPPED SIGN ® SITE SIGN AGE RAMP UP WITH ACCESSIBLE SIGN 7% TO 7.5% SLOPE ONE PER SPACE CONCRETE RAMP UP WITH SIDEWALK 7% TO 7.5% SLOPE 1 /4" GROOVE \?�� AT 3" O.C. CONCRETE Cj SIDEWALK 0 WHEEL STOP 1 ,113 WHERE OCCURS DETECTOR 1!� WARNING ACCESSIBLE SYMBOL (PAINTED) ONE PER SPACE NOTES: 1. THIS DETAIL IS TO ISSUSTRATE THE MAJOR COMPONETS REQUIRED FOR A.D.A.A.G. PARKING. REFER TO THE SITE PLAN, SHEET T-2 FOR THE ACTURAL LAYOUT AND NUMBER OF SPACES TO BE PROVIDED. 2. ALL PAINTED LINES AND STRIPING SHALL BE 4" WIDE: STRIPING SHALL BE SPACED AT 18" ON CENTER: COLOR SHALL BE BLUE OR AS DIRECTED BY THE OWNER N W F O Z J W Z W a 0 a 1n O m Co 0 00 m N o-) � I v d X C w � d E � o a) P 'I- C 0 O o U CI 14 N Q t'r) (n 11 1 PROJECT NO. COMMENCED PHIL ROBLES REVISIONS DATE REV, B 02/08/05 SCALE 1 /4" 1 FT ADA-2.D WG 02/08/05 1 HAIDICAPPED ,"DARKING STALE F.A I q�, �