HomeMy WebLinkAbout10146574.pdft
GENERAL NOTES
1.
ALL
CONCRETE SHALL BE 520—C-2500
MIN,
2.
ALL
LUMBER SHALL BE DOUGLAS FIR
# 1 & #2 OR EQUAL.
3, CONTRACTOR TO REFERENCE THE CALIFORNIA BUILDINC
CODE 2001EDITION,
� 4 i
MIGUEL PUENTE
DATE:
MUNO RESIDENCE
m w 0
HOME ADDITION
1402 W. WASHINGTON AVENU
SANTA ANA, CA 92706
LEGAL
DESCRIPTION:
LOT 10 OF TRACT.:!
COUNTY OF ORANGE, STATE OF CALIFORNIA AS PER
RECORDED IN BOOK 21 PAGE 5 OF MISCELLANEOUS MAPS,
IN THE OFFICE OF THE COUNTY REM COUN )I
EXISTING HOUSE _
NEW ADDITION =
TOTAL =
921 SQFT.
732 SQFT.
1635 SQFT.
Ole
llm ssrfr
W
SAC
WA9WNWCM A"UE
a
N
VICINITY MAP
NTS
SHEETINDEX
SHEET 1.
SHEET 2.
SHEET 3.
SHEET 4.
SHEET a.
SHEET f.
SHEET 7.
S i E ET 8.
SHEET 9.
TITLE
EXISTING SITE/FLOOR PLA•"i-• ••' PLAN '
ELEVATIONSUTILITYIDOOR & WINDOW PLAN
FOUNDATION PLAN
FRAMING/ROOF •
SECTIONLAN
DETAILS
T!
a
4- C-0
1-7
to
v to
MAR 0 1 too$
City Of Santa Ana
w
w
0
06
v
EXISTING FLOOR PLAN
11 � 1 11
1/8 �l mo
47'Fll'
Mma
11 0
A
l°
:2 Mm to] :101,410 :4 oll 0 1 ATA A Itolol ME a U Wm,,Iliu
r
H
ui
ui
2
CD
UTILITY PLAN
- Ul
1, ALL ELECTRICAL TO BE INSTALLED
PER CALIFORNIA ELECTRICAL CODE 2001 EDITION
2a WATER LINES TO BE INSTALLED
PER CALIFORNIA PLUMBING CODE 2001 EDITION
3, PROVIDE LIGHT AND SWITCH IF MECHANICAL IS
GOING TO BE INSTALLED IN ATTIC PER
CALIFORNIA MECHANICAL. CODE 2001 EDITION
4. DUPLEX RECEPTICLES SHALL BE INSTALLED
IN ALL LIVING AND SLEEPING ROOMS SO THAT
NO POINT ALONG ANY LENGTH OF WALL 2'-0" OR
GREATER IS MORE THAN 6'-0" FROM ANY OUTLET
5, ARC FAULT PROTECTION REQUIRED ON ALL
BEDROOM RECEPTICLES
6. ALL EXTERIOR GFI RECEPTACLES SHALL
BE WEATHERPROOFED
7. WINDOWS 1, 2, 3, & 4 SHALL MEET MIN. 5.7 SQFT
EGRESS REQUIREMENT
8, LIGHT & VENTILATION SHALL BE BE CALIFORNIA BUILDING
CODE 2001 EDITION SECTION 1202 MINIMUM OF 15 CFM
OF OUTSIDE AIR PER OCCUPANT
UTILITY NOTES
CEILING MOUNT FIXTURE
110. VOLT DUPLEX OUTLET
1
WALL MOUNTED FIXTURE
110 VOLT GFI DUPLEX OUTLET
SINGLE POLE SWITCH
4>
TELEPHONE
--�
CABLE TV
3/4" HOSE BIBB WITH
BACKFLOW PREVENTION
Q
EXHAUST FAN
WfH
WATER HEATER W/SEISMIC STRAPS
4" DRYER VENT THRU ROOF
2" VENT
Q
SMOKE DETECTORS INTER—
CONNECTED W/BATTERY BACKUP
A
LAUNDRY ROOM CLOSET
D
DRYER
w
WASHER
AF
ARC FAULT
22 X 30 ATTIC ACCESS
31'1'611� 1 1=011
-11 XF17A
MIA L*""m q
0
WINDOW SCHEDULE
WINDOW
WIDTH
HEIGHT
TYPE
1
6'
4'
SLIDING - SMALL MEET
5.7' SQFT, MIN.
EGRESS REQUIREMENT
2
6'
4'
SLIDING - SHALL MEET
5,7' SOFT. MIN,
EGRESS REQUIREMENT
3
6'
4'
SLIDING - SHALL MEET
5,7' SOFT. MIN,
EGRESS REQUIREMENT
4
6'
4'
SLIDING - SHALL MEET
5.7' SOFT. MIN.
EGRESS REQUIREMENT
5
6'
4'
SLIDING
6
3'
4'
SLIDING
7
3'
4'
SLIDING
8
3'
4'
SLIDING
9 X2
2'
2'
SLIDING
10
4'
4'
SLIDING
11
3'
4'
SLIDING
12
3'
4'
SLIDING
13
2'
3'
SLIDING
14
2'
3'
SLIDING
15
2'
3'
SLIDING
DOOR SCHEDULE
DOOR
WIDTH
HEIGHT
TYPE/MATERIAL
fl01
2'6"
6'8"
WOOD
002
3'
6'8"
WOOD
003
6'
6'8"
PATIO/WOOD
004
3'
6'8"
WOOD
005
3'
6'8"
WOOD
Ofl6
2'6"
6'8"
WOOD
Ofl7
2'6"
6'8"
WOOD
fl08
6'
6'8"
SLIDING/GLASS
009
3'
618"
WOOD/LOUVERED
Z:i
Fm
ui
ui
2
N
mzomlisL
101
161
SUN
NEW CLASS "A"
ASPHALT SHINGLES TO
MATCH EXISTING HOUSE
12' x 2 4' 12" x 2 4 *" 12" x 24"
VENT DORMER 7VENT DORMER / [- VENT DORMER
4" VENT
NEW 7/8" THICK
STUCCO TYPICAL TO
MATCH EXISTING HOUSE
woollommillal
EAST to s""IDE
WEST SIDE
KIM
EXISTING HOUSE
i FE Wanjo
12" x
VENT
swam l 1111 /411 1 Olowmo--
24//
DORMER
2' VENT
16f
NEW CLASS "A"
ASPHALT SHINGLES TO
MATCH EXISTING HOUSE
NEW 7/8" THICK
STUCCO TYPICAL
MATCH EXISTING
161
12" x 2 4'
VENT DORMER
NEW CLASS "A"
ASPHALT SHINGLES TO
MATCH EXISTING HOUSE
VENT
NEW 7/8" THICK
STUCCO TYPICAL
MATCH EXISTING
SOUTH E33 DE 1/411.1 I= 11
EXISTING
ASPHALT
CLASS "A"
SHINGLES
EXISTING 7/8" THICK
STUCCO TYPICAL
NORTH t`3"IDE 1/411.1 Imoll
TO
HOUSE
161
I
NOTES
FOR FLOOR FRAMING SEE
GIRDER TO PAD & FLOOR
JOIST TO GIRDER DETAILS ON
SHEET 9 & SECTION VIEW
ON SHEET 8
331
,-% /I If .4 "
FDUNDATIDN
- - --- --------
2 X 8 P.T.D.F. SI
r 'd r r—i Mt m .rryrr--
PROPOSED FLOOR
FRAMING PLAN
SCALE 1/4 1
SILL
2 X 4 P.T.D.F SILL
ISTS
I
NOTES
FOR WALL SHEATHING SEE DETAILS ON
SHEET 9 (SECTION A--2) & SECTION VIEW SHEET
2 X 4 DOUBLE TOP PLATES
W/MIN, 48' LAP SPLICES
X 6 HEADER
4 STUD WALL
@6 p C.
2 X 6 P.T.D.' SILL
FRAMING DETAIL
I%
4X6 HD.
I L'j [4t Al '�XLJIMM&Mflh
___M:JW
of Am
-;J � Aftl M I L
22 X 30 ATTIC ACCESS
(SEE SHEET 4)
2 x 6 STUD WALL 2 16" O.C.
%aaI////////m
• s
All \ /cPiT
ROOF PLAN 1 /4 wars" 1 m 0
n
H
lu
Lu
3:
cl)
�r
m
1
c
D
SECTION S=2
1/2, 1 mo
11 � 1 11
MOTES
BOARD
ROOF RAFTERS
3; (2) 2 x 4 TOP PLATES (SEE DETAILS ON SHEET 9)
4, 2 X 4 STUDS @ 16" O,C,
5, R-13 INSULATION
4 7,
2 X 6 FLOOR JOISTS @ 16" O,C, (SEE DETAILS ON SHEET 9)
8,
1/20 CDX PLYWOOD ROOF SHEATHING <SEE DETAILS ON SHEET 9)
9,
4 X 4 POST (SEE GIRDER TO PAD DETAIL ON SHEET 9)
5 10,
3/8'" CDX PLYWOOD WALL SHEATHING (SEE DETAILS ON SHEET 9)
11,
5/80 DRYWALL
12,
5/8" FLOOR SHEATHING PLYWOOD CDX (SEE DETAILS ON SHEET 9)
13,
18" X 18" CONCRETE PAD (SEE PAD DETAILS ON SHEET 9)
14,
4 X 10 GIRDER (SEE GIRDER TO FLOOR JOIST DETAIL ON SHEET 9)
15,
2 X 8 FLAT P,T,D,F SILL (SEE DETAIL ON SHEET 9)
16,
R-30 INSULATION
17,
R-19 INSULATION
18,
2 X 4 BLOCKING
19,
2X6STUD WALL @16"O,C,
20,
(2) 2 X 6 TOP PLATES
21,
2 X 4 P,T,D,F SILL
22,
2 X 6 P,T,D,F SILL
23,
4 X 6 HEADER
24,
2 X 6 CEILING JOISTS @ 16" O.C.
25,
7/8'v TYPICAL STUCCO TO MATCH EXISTING
STUCCO TO BE PLACED PER TABLE 23-2H
OF THE 2001 CALIFORNIA BUILDING CODE,
26,
CLASS "A" ASPHALT SHINGLES
E�
NOTE:
1, STUCCO TO BE PLACED PER TABLE 23-2H
OF THE 2001 CALIFORNIA BUILDING CODE.
1-3/4' OVERHANG
OR HATCH EXIST.
IX4FACIA .
3/6' CBX PLYWOOD VALL
SHEATHING W/8d COK 0H
NAILS a 6'A Ae' OVER -�
2 X 4 STUD WALL ! W
OC (ON ALL NEW VALLS)
__..^".�
STIMOO
1/2' CBX PLYWOOD
ROOF SHEATHING W/
0d COMM NAILS !
6',6',12' OVER 2 X 6
RAFTERS ! 16' O.G
CLASS A ASPHALT
SHINGLES
R-30 I SULATOHN
PAID DETAIL
2 X 0 FLAT P.T. SILL V/
3/Ni' X w MA, ANCHOR
2 X 4 STM V41
BELT ! 4Y Q.C. W/
2' X L" X 3/16' VASFER
HIM, 71 INTO CW- i0:'
7/!' THICK STUCCO
FREW CORNERS
TVPO:AL TO IMTCH EIOSTING
l/4•
SCREV NAiLM
X 6 FLDat .MilSTS
2 X 4 PTJW SILL
! 16 INCH OC:
2 X 6 lWgCLiG
tc axaPT.DF
WILL
VEEP SCREED
•
1-6•lON
' NDN
2 a 4 BARS
NATURAL
•:`
TOP i M1T[TtMN
SECTION
A--2
SECTIDN A-1
FLOOR SHEATMIG
•J/w CDX PLYWOOD
TM P1 32/16 V/
10d COMM3i MARS !
FLnUR
e 1660C. JOINTS
R-19 1 MIL
1SWATHM
CDX PLYWOOD
.G, Pd. W16 W/
d COMMON NAILS !
,6'i10'OVER
XX 6 FLOOR JOINTS
16, VA
i;�i=i=Z� ail
FLMIRR SHEATHING
wr CBx PLYWOOD
XP.L 32/16 W/
10d CONl1Ft NABS !
6',6'i10'OVER
2 X 6 FLOOR JOINTS
e 16' O.C.
6. W TYP.
DETAILGIRDER TO FLOOKF,
JOISTS
FLOLMt SHEATHING
S/w CBX PLYWOOD
T&% P1 32/16 W/
10d COMMON NAILS e
16 DNCHH DC ITS 61. 6' i O13 OVER
2 X 6 FLOOR JOINTS
e 16' O•C•
4 X 10 GIRDER `�. _ PM
4' X 4' POST
6u
Y . =W. P344
Ito
4
•• � •HIDE
GIRDER TO
PAIN DETAIL
TiI
ITO EXISTING
ON EPDXY
Mw 'ET-22'
4SPECTION REMJW=
O.C.
V2' cm PLYVm
ROOF SHEATHING W/
3d COMMON FAILS !
5',6',12' DYER 2 X 6
WITERS a IV w (two
SECTION B-Z
SECTION B-4
7 74