HomeMy WebLinkAbout10148301.pdfGENERAL NOTES 1. The Contractor shall visit and inspect the job site, familiarize himself with site conditions, and study these documents fully before agreeing to work on the project. His agreement to work on the project constitutes verification that he has so studied the job site and the documents prior to commencing construction. 2. Upon inspection of the site and studying of the documents, the Contractor shall submit to the owner for review any special conditions or unclear areas, which might alter the bid during construction. 3. Any changes or additions to the project shall be approved by the owner prior to construction. 4. There are to be no substitutions of materials or products without the owner's approval. 5. All sub -contractors shall be responsible for the removal of all debris accumulated as a result of their operation. All scrap debris and other excess material shall be removed from the site, unless otherwise directed by the Contractor. 6. The drawing are necessarily schematic and are not intended to show complete situations; the Drawings, 5pecif ications, and Addenda are complainant, therefore what is called for by one is called for by all. As such, the Drawings, Specifications, and Addenda must be considered as a whole. 7. DO NOT SCALE DRAWINGS! TITLE 24 1. All weatherproofing around windows and doors shall be performed in accordance with manufacturers' requirements. Any special conditions where installation has to be altered shall be presented to the Owner in writing for approval. 2. Comply with the California Energy Commission (GEC) laws enforced. 3. Insulate all exterior partitions with full thick batts. Use sound full batts at walls enclosing bathrooms, laundry rooms, FAU closet and any other interior partitions as called for by the drawings. 4. Caulking or weather stripping: a. Around all doors & window frames. b. Between wall bottom plates & concrete and between plates to the exterior. c. All penetrations in walls, ceilings, floor due to the installation of plumbing, electrical, gas and HVAC lines, d. All openings in attic. e. All other openings in bldg. envelop. 5. Insulation: a. All exterior walls: R-13 batts. b. Floors: R-19 c. All flat ceilings wl attic space above-, R-30 6. Contractor shall sign and post on the structure an Insulation Certificate prior to the finish inspection. A CITY PERMITTING REQUIREMENTS 1. Separate plans, application fees and plan checks may be required for mechanical, plumbing and electrical work. Contact permit tech at 714.647.5800 2. The permit applicant must notify the designers of the other construction disciplines including electrical, plumbing and mechanical of changes in use/occupancy. FRAMING NOTES 1. All construction shall conform to the 2001 CBC. 2. All framing shall be D.F. #2 or Better, unless otherwise noted. 3. Refer to SHEAR PANEL SCHEDULE for sill panel nailing at shear panels. 4. Typical joist hanger/connectors beam to post shall be "SIMPSON" hardware unless otherwise noted. 5. Studs in exterior walls and bearing partitions may be cut or notched no more that T its width and studs for non -bearing walls no more that 40% its width. Bored holes shall be limited to 40% width in any stud located at least 5/8" from edge of studs. 6. All 4x8 and larger headers shall have double trimmers at each end of header. 7. All nailing shall be per UBC table 23-I-Q nailing schedule. 8. Fire blocking shall be provided at all drop ceiling and soffits. It should also be provided at floors and ceilings and at mid -height of walls greater that 10'-0" 9. Where top plate or sole plates are cut for pipes, a metal tie, min. 0.058" thick, 1.5" wide shall be fastened across the opening wl (6)-16d nails min. each side. 10. If certain conditions are not shown or detailed, their construction shall be of the same general type as that which is shown or detailed and shall follow standard construction practices. 123 1 0 0 0 12' wo I. 60 LA VERNE (LOCAL ST) SCALE: 1/8" = V-0" LEGAL DESCRIPTION Address: 2302 W. La Verne Santa Ana, CA APN#: 109-122-14 Tract: 1346 Lot: 29 Occupancy Group: R-3, U-I Construction Type: V-N TABULATION OF BLDG AREA Area Exst'g New Dwelling 812 242 Garage (Attached) 351 Exempt Total 1254 0 Total: 1254 SCOPE OF PROJECT Bedroom and bathroom addition to the rear of a 1-story single-family dwelling. NuiG R 1_,117 /Z I i"11141667-2700 "U, 'A' , ­5146119 4-v ffERO Lim SITE/ROOF PLAN, LEGAL DESCRIPTION, GENERAL NOTES FIRST FLOOR PLAN, FOUNDATION PLAN., SHEAR WALL SCHEDULE, ROOF FRAMING ELEVATIONS, SECTIONS, DETAILS TITLE 24 COMPLIANCE FORMS MIN LIGHT REQUIREMENTS (BEDROOM),. ROOM AREA=132 SQ FT WINDOWS AREA=18 SQ FT. "Y132 = 13.6% okay. MIN OF 15 CFM OF OUTSIDE AIR PER OCCUPANT IS REQUIRE[) FOR VENTILATION, NO 1. New Walls Remove Wails Existing Walls 2. Interior Walls: Walls and c1gs to be covered w/ 5/8" gyp bd; 6d cooler nails or 1­21" drywall screws @ 7" o/c edge & field. 3. Minimum of 15 CFM of outside air per occupant is required for ventilation. 4. Bathroom Notes a. Provide water-resistant _gyp backing board as base for tile, wall panels for tub/shower enclosure & W.C. compartment Walls. b. Showers shall have a smooth, hard non -absorbent surface of Portland cement, concrete, tile or other smooth hard non -absorbent surface,to a height of 70", with a water-resistant backing. c. Anti -scalding shower, tub and shower valves per UPC 410.7 d. MIN 2x6 PLUMBING WALLS slip -joint or use non -slip welded joint. e. Vents: 5 air changes per hour shall provide wl 1/5 of air from outside. Exhaust system - All exhaust shall be type to prevent air leakage by use of backdraft or automatic dampers. Certified by CEC. f. Max flow rate standards set by CEC: W.C. 1.6 GPF Showerhead 2.5 GPM Sink Faucets 2.2 GPM 9. Access panel, 12"42", req'd for tub trap slip -joint or use non -slip welded joint. I 61L T71016701412 ,W 0 1TZAZ• DOOR and WINDOWS: All manuf. doors and windows shall be labeled and certified by the Calif. Energy Comm. All glazed doors & windows shall be double -glazed per energy talcs. Provide safety glazing (tempered) at hazardous locations: glass doors to building's exterior (sliding or French type), doors to tubs & showers*, doors serving as tub or shower enclosures*, wardrobe doors, all windows within 18" of the floor, all windows within 5' of bottom of the stairs and all windows within 24" of door edge. (sec 2406) - Shall have 3/16" temp glass or laminated glass or approved plastic. All bedrooms shall have emergency rescue windows or doors Min. net clear opening of 5.7 sq. ft. Min. net clear opening width of 20" Min. net clear opening height of 24" Window sill height of 44" above floor. Locks: As directed by owner. FLASH AROUND ALL EXTERIOR DOOR AND WINDOW OPENINGS WITH APPROVED FLASHING. 1k ELECTRICAL NOTES All wiring must comply with the 2001 California Electrical Code. WORK INCLUDED, All labor, material, and equipment to properly complete all electrical work other than that which is provided by the utility company. SWITCHES shall be mounted at 48" high unless otherwise noted. Dimmer switches shall be 600 watts, located per plan. Receptacles shall be installed at 12" above finished floors except as shown on plans. Receptacles in bathroom shall be installed above the worktop except as shown on plans. RECESSED LIGHTS at insulated ceiling shall be UL-listed for direct contact with insulation. (ICT type) SMOKE DETECTORS shall be State Marshall approved, wired into the house's circuitry and equipped with a battery backup. They shall have no disconnecting switch, outside of those for overcurrent protection. They are required in each room used for sleeping, centrally located in the wall or ceiling in corridors providing access to each separate sleeping area, at each floor. (CBC 310.9.1.4) PROTECT all outlets with GFI circuits at the following locations: bathrooms, outside, and at all kitchen counters and islands (NEC 210-8a) BATHROOMS: General lighting to provide at least 40 lumens/watt. CLOSET LIGHTS. Provide cover dt locate 12" min, away from shelves. (NEC 410-8) OUTLETS: Spaced 12' o/c max, located within 6' of door openings, on every 2' or wider of wall, within 2' of end or breaks of counters. 6 3 18"44" FLOOR I ACCESS 3 2X6 F/J @ 12" O.C. A VA 6"42" VENT Z 9 4X8 GIRDER, TYP 2X6 F/J @ 12" O.C. VA 11 11 F- SCALE: 1/4" = 1' -0" 2 3 3 4' 4' 7 T_V__ 4 Xs HDR 2X8 C/JT @ 16" O.C. I — M -,,.rA 1 a- r 2X8 R/k @ 16" O.C. r/A 2X8 R/R @ 16" O.C. Ji L 4 4 4' 3 4' IT (XM 06 HOR PROVIDE FLOOR VENTILATION EQUAL TO 15o OF FLOOR AREA (APPROX. 240 SQ IN) VIA (1) 18flx24" ACCESS, (2) 6'42" VENT 6'42" VENT VM Wo FM W Ait LJ t/r Z 08 HDP Z W ix CZ Ly ROOF FRAMING SCALE: 1/4" = V-0-1 FOUNDATION NOTES USE TYPE V CEMENT, 2500 psi COMPRESSIVE STRENGTH AT 28 DAYS. LZZZZZZZ�� NEW FOOTING PER DETAIL EXISTING FOOTING FLOOR DIAPHRAGM: USE 3/4" STRUCT I, C-D OR C-C PLYWOOD T&G, WITH 10d NAILS AT 6" O.C. EDGES, 6" O.C. BOUND & 12" O.C. FIELD. UNBLOCKED DIAPHRAGM PANEL INDEX 48/24 LAY PLYWD PERPENDICULAR TO SUPPORTS 2011 ROOF DIAPHRAGM: USE 1" C0X PLYWOOD W/ 8d NAILS AT 6" O.C. EDGES, 6" O.C. BOUND & 12" O.C. FIELD. UNBLOCKED DIAPHRAGM PANEL INDEX 24/0 LAY PLYWOOD PERPENDICULAR TO SUPPORTS. SHEAR WALL: W WALL SHEATHING - STR, II PLY WITH 8d @ 4" o.c. E.N. & 12" o.c. F.N. SILL - 5/8" A.B. @ 48" o.c. TOP ANCHORAGE - SIMP A35 @ 16" o.c. USE 5/8" DIAMETER BY 10" LONG ANCHOR BOLTS WITH 2-1" SQUARE x T" THICK WASHERS. Ln _t Nt a 0C_ U n 0-7.0. 'A L, 'N EXIST'G NEW r SOUTH ELEV. SCALE: 1/4" = V-011 NG EAST ELEV NEW EXISTI SCALE: 1/4" = 1'-011 WEST ELEV. SCALE: 1/4" = 1'-0" (N) BA R-30 @ CLG BED #3 (NEW) -1 00 A 0 R-19 @ FLOOR FOO SCALE: 1/4" = I' -Oil 07 FMI R-13 @ WALLS NEW SHEAR PANEL—, PER PLANS 3x BLKG W/ 5/161.13 0 4"O/C E.N. 2XBLOK'G W/E.N NEW F.J EXISTING OR NEW STUDS. 2x P.T. MUD -SILL W/SIMP.ET,5/8" 0 STUD W/ 3/4' DRILL PIT.@ 16- O.0 SAME SIZE & SPACINGS AS A.B'S. CALLED FOR IN SHEAR SCHED. 4 1/4" MIN EMBDMT INTO EXIST`G FO0T`G FOR MORE INFOR (ICBO#4945)(U.O.N). Ln EXISTING F.J. - I SEE PLAN FOR JST DIRECTION 1T EXISTING FOOTING ELEVATION NOTES FI-] Roof Material: Composite Class A shingle to match existing. Place over 30# felt. F-2] Roof ventilation: See Roof Notes r8i All trim/fascia to match existing. F4-] Moisture -stop flashing around all windows, doors, and other openings. 7/8" stucco shall comply with Chapter 25 of the UBC. Provide separate inspections for each phase of exterior plaster as follows: scratch coat, brown coat and color coat. Secure wire lath with furring nails. Use (2)-15# felt backing when stucco is applied o/ply (UBC 2501.4) Use 60 minute minimum building paper for stucco that does not have a plywood backing. [-6] 411 stucco weep. Min grade plywood at overhangs to be CCX or 0 1x T&G sheathing. [#] Address clearly visible from street. ROOF NOTES 1, Valley flashing: 28 gauge corrosion resistant (gale) sheet metal over 30# felt. 24" wide with I" high diverter ridge at center. 4" min lap line at ends. 2. Flash all roof penetrations with 28 go min gale sheet metal. 3. Provide roof ventilation equal to 1/300 of roof area with 50% in upper half of attic. Use I 12"x16' gable vent. Also, provide 2 holes/block for eave ventilation. Use 1/4" corrosion resistant metal mesh covering. SCALE: 1/4" = l'-O" 8d NAILS @ 4" O.C. 2 X BLOCK'G @ 4' O.0 W/ E.N. t % BM. PER PLAN SIMP A35 E.N. @ 161, O/C 2x, SLOCK'G. 44 IMP A35 O/C F@1 6 NEW FTG REINF. 18" MIN /�-PER PLAN /-#4 DOWELS @ EA. FOOTING REINF'& 3/4" 0 HOLE @ EA `-NEW FTG #4 DOWEL, FILL W/ EPDXY PER PLANS :ST'G FOOTING E.N.-- SHEAR WALL PER PLAN SHEATHING SIMP ST 22 @ 4' O/C nr!r% ni A K I MTtNr-C Dt:n DI AKI 17 13 1 WALL __,.- -SHEAR PER PLAN ROOF SOLE PLATE SHEATHING-\ NAILING 2x4 FLAT FINGER @ 23" O/C 2- 8d FINGER NOTCH INTO ROOF JST, W1 2X BLK*G NAIL 72" - 16b F/J PLAN 7R END NAIL'& 4" CLEAR 2X P.T. D.F. MUD 2x ROOF J5T. W/ 6" MIN PLATE W/ V8" 0 16d @ 16" O.0 TO_____ 2x ELKS @ 72" O/C W/ 18" MIN STEM X 10" LONG A.B. e PLATE. SPLICE W1 3 - 16d TO FINGER & 48" O.C. U.O.N.; SIMP ST12 STRAP 2 - 16d TOE NAILS TO EMBED A.B. 7" MIN PLATE 1211 INTO CONCRETE SHEAR WALL (1) NO. 4 SAP. @ TOP & BOT. 1211 A 6" MIN 4" CLEAR 1211 8d @ 611 O.C. (STAGG.)-\ ROOF RAFTERS-\ �--ROOF /// SHEATHING 8d AT 6" O/C E.N.-\ \ \ SIMP A35 @ 1611 0/ 2x BLOCKING- \\ \,/(4) 16d @ CIJ TO R/R E.N. 'E.N. <1 SHEAR WALL SHEAR WALL [> PER PLAN FASCIA PER PLAN 4—STUD WALL I= Lid "t a U C- 0 U >1 n c- CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page I of 3) CF-IR BALTODANO ADDITION 2.25.05 Project Title 2302 W. LA VERNE Date Project Address JON UDOFF 714.345.1760 Building Permit # Plan Check / Date Documentation Author Tel hone PACKAGE D I Field Check !Date Compliance Method (Package or Computer) Climate Zone GENERAL INFORMATION Total Conditioned Floor Area 241 ft2 Average Ceiling Height: -,§- ft Conditioned Slab Floor Area ft2 Building Type: X� Single Family X Addition (check one or more) -Multi-Family - Existing -Plus -Addition Front Orientation: 00 (gart South / East / West / All Orientations (input front orientation in degrees from True North and circle one) Number of Stories 1 Number of Dwelling Units: 1 Floor Construction Type: (Slab Raised Floor (circle one or both) RADIANT BARRIER (required in climate zones 2,4,8-15) Required for this submittaIX yes - no 11-1191*01VI 1,11411 Component Type Frame Type wd = wood stl = steel Cavity Insulation R-Value Sheathing Insulation R-Value Total R- Value' Assembly U-Factor Location/Comments (attic, garage, typical, etc.) Wall WOOD Wall Roof WOOD R-30 Roof Floor WOOD Floor Slab Edge , tot mscrtritivecoLrptiance, iota, K-vatue ano /-xssemojy u-raciprare not requircu cur a wu1L)u_irainuU watt .teat 11Jr0t5Ui2V1LY r­Vc11U%; insulation requirements for the Prescriptive Package. FENESTRATION Shading Devices Fenestration #/Type/Pos. Orien- tation Area M Fenestration U-Factor Fenestration SHGC Exterior Shading Art. Overhangs/ Fins Front Front Left Left Rear SOUTH 18 .40 .35 Rear Right WEST 4 Right .40 .35 Skylight Skylight_J_ Compliance Forms August 2001 CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 2 of 3) CF-1R BALTODANO ADDITION 2.25.05 Project Title Date HVAC SYSTEMS Note: Input hydrome or combined hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Heat Pump Type (furnace, heat Efficiency Location Piping Thermostat Configuration pump, etc.) (AFUE or HSPF) (ducts, attic, etc.) R-Value Type (split or Effjge) SPLIT USE (E) MIN ATTIC SETBACK Cooling Equipment Minimum Duct Heat Pump Type (air conditioner, Efficiency Location Duct Thermostat Configuration heat pump, ovap. cooling) (SEER) (attic, etc.) R-Value Type Lsph Lt or package) SEALED DUCTS and TXVs (or Alternative Measures 0 Sealed Ducts (all climate zones) (Installer testing and certification and HERS rater field verification required) El TXVs, readily accessible (climate zones 2 and 8-15 only) (Installer testing and certification and HERS Rater or field verification required) F-1 Refrigerant Charge/Air Flow (climate Zones 2 and 8-15 only) (Installer testing and certification and HERS Rater or field verification required) OR N Alternative to Sealed Ducts and TXVs (see Package C or D Alternative Package Features for Project Climate Zone) Climate Zone Window SHGC Window U -Factor SEER Heating 8 .35 0.40 WATER HEATING SYSTEMS Energy External Rated, Tank Factor or Tank Water Heater Distribution Number Input (kw Capacity Recovery Standby' Insulation Tyne Tvve in System or Btu/hr) fizallons) Efficiency Loss (%) R-Value For small gas storage water heaters (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance, and heat pump water heaters, list Energy Factor. For large gas storage water beaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list rated input and recovery efficiencies. SPECIAL FEATURES (add extra sheets if necessary) Package C and D: TXVs, Sealed Ducts, Radiant Barriers (see installation requirements for radiant barriers in Section 8.13 of the 2001 Residential Manual). Package C: thermal mass (thermal mass type, covering, thickness and description). CERTIFICATE OF COMPLIANCE: RESIDENTLkL (Page 3 of 3) CF-IR BALTODANO ADDITION 2.25.05 Project Title Date This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts I and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. The undersigned recognize that compliance using duct sealing and TXVs requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business and Professions Code) Name: JON UDOFF Title/Finn: Address: 2383 LYRIC AVE LOS ANGELES CA 90027 Telephone: 714.345.1760 Lk . #J) I Ay- V 0'. (signal (date) Enforcement Agency Name: Title: A i7enev- Documentation Author Name: JON UDOFF Title/Firm.- Address: 2383 LYRIC AVE LOS ANGELES GA 90027 Telephone: 714.345.1760 (signs e) u (date) Compliance Forms August 2001 MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page I of 2) MF-1R Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures: * § 150(a): Minimum R-19 coiling insulation. X § 150(b): Loose fill insulation manufacturer's labeled R-Value. X * § 150(c): Miniumum R-13 wall insulation in wood framed walls or equivalent U-Factor in metal frame walls X (does not ay to exterior mass walls). * § 150(d): Minimum R-1 3 raised floor insulation in framed floors. § 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission Tate no greater than 2.0 perni/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. X § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exflltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. X 2, Fenestration products (except field -fabricated) have label with certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with § 151 meets Commission quality standards. X § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilot lights allowed. Space Conditioning, Water Heating and Plumbing System Measures: § 110- 113: HVAC equipment, water beaters, showerbeads and faucets certified by the Commission. X § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA OR ACCA. X § 150(i): Setback thermostat on all applicable heating and/or cooling systems. X § 150(i): Pipe and tank insulation 1. Storage gas water beaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (RA or greater) X 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-I 6 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55T insulated. 6. Piping insulated between heating source and indirect hot water tank. MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page 2 of 2) M&IR Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable, DESCRIPTION DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirement of the 1998 CMC Sections 601, 603, 604, and Standard 6-3; ducts insulated to a minimum installed level ofR-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 18 1B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawhands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials X other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and suport platforms shall not be compressed to cause reductions in the arm -sectional area of the ducts. 3. Joints and seams of duct systems and their comprients shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. § 114: Pool and Spa Heating Systems and Equipment. 1. System is certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch, §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no X continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot<150 Btu/hr) § 118 (f): Cool Roof material meet specified criteria Lighting Measures: § 150 (k)l.: Luminaires for general lighting in kitchens shall have lamps with an efficacy of40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily X accessible lighting control panel at an entrance to the kitchen. § 150 (k)2.: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of*40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this in incandescent fixtures IC X requirement allowed § 150(k)2.; and recessed ceiling are (insulation cover) approved. Forms August 2001 WON 9ti 1111 14AM