Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10148078.pdf
a s F, F-1, S 13 PINNACLE ♦ * ♦ ♦ rr r r. ♦ CE 31 MAC ARTHUR CRESCENT SPAC; ♦ ♦ ♦ i , CALIFORNIA AGOUS. ACOUSTICAL LAV. LAVATORY A1C AIR CONDITIONING Le. LENGTH, LONG A.F.F. ABOVE FINISHED FLOOR ALT. ALTERNATE MAR. MARBLE ALUM. ALUMINUM MAX. MAXIMUM ANOO. ANODIZED MECH. MECHANIC (AL) A.P. ACCESS PANEL MET. METAL ARCH. ARCHITECT (URAL) MIN, MINIMUM MIR. MIRROR BD, BOARD MLP. MOLOING,MOULDING BLPG. BUILDING MTV. MOUNT (ED), (ING) BRZ. BRONZE MUL. MULLION CAB. CABINET N.I.C. NOT IN CONTRACT CEM. CEMENT NO. NUMBER CK, CAULK N.R.C. NOISE REDUCTION COEF. CLG. CEILING N.T.S. NOT TO SCALE CLO. CLOSET CLR. CLEAR (ANGE) O.A. OVERALL COL. COLUMN O.G. ON CENTER (5) GONG. CONCRETE O.D. OUTSIDE DIAMETER CONST. CONSTRUCTION OFF. OFFICE G.T. CERAMIC TILE CTR, CENTER PR. PAIR PART. PARTITION DBL, DOUBLE PLWD PLYWOOD PET, DETAIL P.T. PAINT D.F. PRINKING FOUNTAIN PIAG. DIAGONAL QT. QUARRY TILE DIAM. DIAMETER QTR, QUARTER DIM. DIMEN51ON PN. DOWN RAD. RADIUS DR. DOOR R.B. RUBBER BASE DWG. DRAWING RECEP. RECEPTACLE REF. REFERENCE ELEV. ELEVATION, ELEVATOR REFR. REFRIGERATOR EMER. EMERGENCY REV. REV15ION (5), REVI5EP EQ. EQUAL REQ. REQUIRED EXH. EXHAUST RM. ROOM EXT EXTERIOR S.G. 50LID CORE F.P. FLOOR DRAIN 5CH. SCHEDULE F.E.G. FIRE EXTEN(SUISHER CABINET S.F. 50UARE FEET F.F. FINISH FACE SHT. SHEET F.H.G. FIRE HOSE CABINET SIM, SIMILAR FIN. FIN15H (ED) S.S. STAINLESS STELL FLR, FLOOR 5TD. STANDARD FND. FOUNTAIN 5TA. STATION FT. FOOT STL. STEEL FUR, FURRED (ING) 5U5P. SUSPENDED GA. GAGE, GAUGE TEL. TELEPHONE GL. 6LA55, GLAZING TEMP. TEMPERED GRAN. GRANITE THK. THICK (NESS) GYP, GYPSUM THR. THRESHOLD T.V. TELEVISION H.C. HOLLOW GORE TYP. TYPICAL HCP. HANDICAPPED HDWR. HARPWARE UNFX UNFINISHED HGT. HEIGHT U.O.N, UNLESS OTHERWISE NOTE H.M. HOLLOW METAL H.V,A.G. HEATINGNENTIAIR/COND, VEN. VENEER Y.I.F. VERIFY IN FIELD I.D. INSIDE DIAMETER VERT. VERTICAL (LY) INT. INTERIOR VT. VINYL TILE JAN. JANITOR W1 WITH WC, WALL COVERING KIT, KITCHEN W.C. WATER CLOSET NO. WOOD LAM. LAMINATE (0) la p� 4wlm % s � Y r ELEVATION REFERENCE DETAIL REFERENCE SECTION REFERENCE WALL FINISH U FLOOR FINISH MILLWORK FINISH © ROOM NO. ® DOOR REFERENCE MANUFACTURERS: L.A. R.R. NUMBER IGBO NUMBER WALL PARTITIONS: GYPSUM A550CIATION #230I61 #18'74 FIRE RE515T DE516N MANUAL. METAL FABRICATION: CALIFORNIA EXP. METAL, CEMGO #244123 #5405P 5TRUCT. AND PART STEEL FRAMING FASTENERS: HILTI POWPER DRIVEN FASTENERS #2552 #1-115P 8 25412P "RAMSET" - SELF -DRILL SCREW FOrm #2566 4 SUPP. NO.1 LIGHT GAUGE MATERIALS "RAMSET" - SHORT SET AND AMMO #22668 #165a "TEK" - SELF DRILLING 50REW5 #25 768-T ACCETT4' ..> G e $: �, i rzu*1 Tg A'lr,l-* FEW178 1,1 This vol olp!vnis. mnd s MfiC,0ulM 02 lulljob at N 3 F c" q ga r gfi a A E s" Ae m, rga a k, s v+'U .Atl 4`,,tt any tw��a*9p or s, : S n <�' to vaeil&e r elf uw t€�s'36'�r thecity of Sanla Aa', The acceptlarme of tr"18 F12NEndl NOT 1 g provisions I Arta. �$ g���,e?'a ���q;,j�e% yk�a Lam Cq: Bp�SC'�°Ed�� s� rovi dio s of A � $ k&y G ri ui 0 c,o c na$a.g'�'e, La liSo 9 �ryy ffi(k4c - 6 ✓ - -eLDate PVf WIA I N�ffi „ �llowIngApplWalge "& n t" k<.+ !M a an �Ft��fi�a E �t ur . "' 'JA SHEET NO, DESCRIPTION A COVER SHEET A.O GENERAL NOTES A.OI MASTER LEGEND A.I PARTITION 4 FINISH PLAN A.2 POWER 4 TEL/ EQUIPMENT PLAN A.5 REFLECTED CEILING PLAN A.4 ELEVATIONS 4 DETAILS A,5 ELEVATIONS 4 DETAILS A.6 ELEVATIONS 4 DETAILS Al DETAILS A•6 DETAILS M.1 MECHANICAL M.2 MECHANICAL E.1 ELECTRICAL E,2 ELECTRICAL E,5 ELECTRICAL P I PLUMBING 31 E. MAC, ARTHUR 5UITE#102, SANTA ANA, CA 41270'7t k �W �.. -.. >v 2 " ♦ y _ 1 ' t ♦ i • A •c Jr . G . G140up— CONSI'M-TYP71,=��." DI O p ccl FLOOD, 2., m P,2 PLUMBING VICINITY MAP P CONSULTANTS fv''� (''� ('`► f''� [� � �'''j FLOOR L.7 ti.J � i �11../ 1 � ti,J ti.J 1 t. as loom ti w+ � Macarthvr P . Firs 1� ��� � �1 #i � x w E cJ T�ESiGNER. JB CONCEPT +DESIGN 320 FAIRPLAIN AVE WHITTIER, GA a0601A CONTACT: JOE BADAW! 626 5641 3'70I 626 4"75 Q'700 GENERAL CONTRACTORS: TBD MEP ENGINEER: PERFECT DESIGN PRELIM LANDLORD REVIEW OV28105 I5sUE17 FOR ENGINERING 01128105 ISSUED FOR HEALTH DEPARTMENT 02/14/05 APPLICABLE CODES ISSUED FOR LL APPROVAL aa1I4105 ISSUED FOR PRICING 02114105 UNIFORM BUILDING GORE - 200I EDITION 2001 CW CODES W1 STATE OF CALIF, AMENDMENTS UNIFORM PLUMBING CODE - ISSUED FOR PLAN CHECK 021l4105 j' LEGAL L.. �,.7 A DESCRIPTION l \ PLAN CHECK CORRECTIONS 5/50/05 HEALTH DEPARTMENT CORRECTIONS 5/50/05 ADDRESS: PINNACLE a MAC ARTHUR SHOPPING CENTER /� ISSUED FOR CONSTRUCTION / UNIFORM MECHANICAL CODE 31 E. MAGARTHUR ORE ENT SUITE# lag SANTA ANA, GA 412'70 7 NATIONAL ELECTRICAL GORE - a ,., TENANT: KELLYS COFFEES FUDGC E FATORY d �..` 31 E. MAGARTHUR GRESGENT,SUITE#m'J02 : W UNIFORM FIRE CODE NATIONAL FIRE PROTECTION ASSOC. (NFPA) i= SANTA ANA, CA 012"707 STATE GALIFORNAI / FEDERAL ADA v;, ._<,<, u CONTACT: MOHAMMAD ODEH x &nz" ;. CALIFORNIA ENERGY COMMISSION; TITLE 24 + ,arthur qaa 5"f6 'lla2 A roved f. N LANDLORD: SRE PROPERTIES` k Dr 2020 MAIN STREET SUITE �` �f50` u' V IRVINE, GA g2614 Project No. r FIIO A '+"- CONTACT: tiAVIP POWERS.: _ -41441665 ISSUO Date 0It28/05 ` U .. TEL: 424' 1 �"� �,( , ,SCOPE O F WORK: : � � ,�� � � BUILDING DATA: FIRST FLOOR RESTRROOM: 65 SQ.FT. (1) '+ PREP FOOD 1 SERVICE : 5413 SOFT (5) DEMOLITION OF EXISTING SUSPENDED CLG AND LIGHT FIXTURES PUBLIC AREA: 472 50.FT (52) .- CONSTRUCT NEW NON -BEARING INTERIOR PARTITION, NEW GYpAl' , , a ws .. < ` a# O tt e 1�,1 � ' • ':� A A I P X (56) OVER � H E ET BD CEILING EXISTING GLASS STOREFRONT AND GLASS DOOR, i EMPLOYEE: 2 NEW LIGHT FIXTURES, 20 S ; eSt.gp 1 "[ .;,` 005 NAvT� g.. SEATING: 12 EXISTING ELEC., PANEL, EXISTING HVAC, NEW PLUMBING OCCUPANCY - B : 56 OCCUPANTS MAX 4 NEW KITCHEN 1 PREP FOOD AREA FULLY 5PRINKLEREP, 3I MAC, ARTHUR 5U I TE# 102, SANTA ANA, CA q2'70'7 TYPE OF CONSTRUCTION : I A NEW SIGNAGE UNDER 5EPERATE PERMIT 4 SUBMITAL, ,a USE . COFFEE SHOP a z. Sheet of L� 1. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND FIELD DIMENSIONS PRiOR TO SUBMITTING HIS BID. ANY DISCREPANCIES, CONFLICTS OR OMISSIONS, ETC., SHALL BE REPORTED TO JS CONCEPT BEFORE PROGEEDIN6 KITH THE WORK. NO ALLOWANCE SHALL BE MADE FOR ANY EXTRA EXPENSE DUE To THE cONTRACTOR'S FAILURE OR NEGLECT TO COMPLETE EXAMINATION OF THE SITE. 2, CONTRACTOR SHALL PROTECT AREAS FROM DAMAGES WHICH MAY OCCUR DURING CONSTRUCTION. HE SHALL PROVIDE AND MAINTAIN TEMPORARY BARRICADES, CLOSURE WALL, ETC., AS REQUIRED TO PROTECT THE PUBLIC DURING THE PERIOD OF CONSTRUCTION, ANY DAMAGE TO NEW OR EXISTIN6 CONSTRUCTION, STRUCTURES AND EQUIPMENT SHALL BE REEPALCED OR REPAIRED TO THE SATISFACTION OF THE TENANT AT THE EXPENSE OF THE GENERAL CONTRACTOR. 3. ALL CONSTRUCTION WORK: ARCHITECTURAL, MECHANICAL, ELECTRICAL, ETC., SHALL CONFORM TO THE UNIFORM BUILDING CODE, LATEST EDITION AS WELL AS ANY OTHER GOVERNING CODES, REGULATIONS, AND ADOPTIONS. 4. THE CONTRACTOR SHALL SUBMIT TO JS CONCEPT FOR APPROVAL A DETAILED CONSTRUCTION SCHEDULE INDICATING PHASING OF WORK AND ANY MECHANICAL OR ELECTRICAL DISRUPTIONS TO BUILDING SERVICES 5. ALL DIMENSIONS ON JB CONCEPT PLANS ARE TO THE FACE OF WALL AS INDICATED, UNLE55 OTHERWISE NOTED, 6. ALL CONSTRUCTION DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS SPECIFIED BY ANY WILL BE BINDING AS IF SPECIFIED BY ALL, ANY NORK SHOWN OR REFERRED TO ON ANY CONSTRUCTION DOCUMENT SHALL BE PROVIDED AS THOU6H ON ALL RELATED DOCUMENT. 1. ALL WORK LISTED, SHOWN, OR IMPLIED ON ANY CONSTRUCTION DOCUMENTS SHALL BE SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR EXCEPT WHERE NOTED OTHERWISE. THE &ENE:RAL CONTRACTOR SHALL CLOSELY COORDINATE HIS WORK WITH THAT OF OTHER SUB -CONTRACTORS OR VENDORS TO ASSURE THAT ALL SCHEDULES ARE: MET AND THAT ALL WORK 15 DONE IN CONFORMANCE TO MANUFACTURER'S RECOMMENDATIONS. a. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL LOCAL REGULATORY AGENCIES, APPLICABLE BUILDIN6 CODES AND REQUIREMENTS. 41. THE GENERAL CONTRACTOR SHALL 5U5MiT TO JB CONCEPT FOR APPROVAL SHOP DRAWINGS FOR ALL FABRICATED ITEMS, IN THE FORM OF REPRODUCIBLE DRAWIN65. HE SHALL SUBMIT CUTS OF ALL FIXTURES, EQUIPMENTS AND SAMPLE OF ALL FINISHES SPECIFIED FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. 10. ALL CONTRACTOR OR SUPPLIER REQUESTS FOR SUBSTITUTIONS OF SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING, ACCOMPANIED BY THE ALTERNATIVE PRODUCT INFORMATION, TO THE DESIGNER, AND WILL BE CONSIDERED ONLY IF IT DOES NOT SACRIFICE QUALITY, APPEARANCE AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE DE516NER BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBTITUTION iS OR 15 NOT of EQUAL QUALITY TO THE PRODUCT 1. INSTALLATION OF ALL SELECTED MATERIALS SHALL BE COMPLETE iN ALL RESPECTS PRIOR TO FINAL ACCEPTANCE. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR PROPER INSTALLATION SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. THE CONTRACTOR. SHALL FURNISH TO THE OWNER ALL NARRANTIE5 AND GUARANTEES REQUIRED AT THE CONCLUSION OF WORK, 12. GENERAL CONTRACTOR SHALL APPLY FOR AND OBTAIN AT THE CONTRACTOR'S SOLE EXPENSE, ALL NECESSARY CONSTRUCTION PERMITS REQUIRED BY ALL APPLICABLE BUILDING CODES AND REGULATORY CITY AND STATE AGENCIES. 15. THE 6ENERAL CONTRACTOR SHALL PROVIDE THE MINIMUM INSURANCE RMOUIREMENT5 5ET FORTH IN ARTICLE 11 OF A.I.A. DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACTOR FOR CONSTRUCTION", 14. CONTRACTOR INSURANCE BOND SHOULD BE PROVIDED FOR THE APPROVAL OF THE OWNER. 15. THE GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DOCUMENTS ON THE JOB SITE DURING ALL PHASES OF CONSTRUCTION FOR USE OF ALL TRADES AND SHALL PROVIDE ALL SUBS WITH CURRENT CONSTRUCTION DOCUMENTS AS REQUIRED. 16. THE GENERAL CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS ON A REGULAR BAS15 AND SHALL EXERCISE 571RUCT CONTROL OVER JOB GLEANING TO PREVENT ANY DIRT, DEBRIS OR DUST FROM AFFECTING THE FINISHED AREAS INSIDE OR OUTSIDE JOB SITE, 11. THE CONSTRUCTION DOCUMENTS ARE PROVIDED TO ILLUSTRATE THE: DESIGN AND GENERAL TYPE OF CONSTRUCTION DESIRED, AND IMPLY THE FINEST QUALITY OF CONSTRUCTION, MATERIAL AND WORKMANSHIP THROUGHOUT. THE GENERAL CONTRACTOR, IN ASSUMING THE RESPONSIBILTY FOR THE WORK INDICATED, SHALL COMPLY Y41TH THE SPIRIT AS WELL A5 THE LETTER IN WHICH THEY WERE DRAINN. 15. IT 15 THE BIDDER'S RESPONSIBILITY TO WALK THE PROJECT, TO BE SURE THEY ARE AQUAINTED WITH THE EXISTING CONDITIONS, AND TO SURVEY THE AMOUNT OF DEMOLITION AND REMOVAL NECESSARY. 141. THE CONTRACTOR SHALL BE HELD RESPONSIBLE TO FURNISH ALL WORK AS SPECIFIED, EXCEPT AS MODIFIED BY CHANGE ORDERS, OR ADDENDA WITHIN (5) WORKING DAYS OF AWARD OF CONTRACT, TO JB CONCEPT FOR REVIEA. 20. INSPECTIONS AND TESTS REQUIRED BY LOCAL GOVERNING AGENCIES SHALL BE PROVIDED WITH ALL COST OF SUCH INSPECTIONS AND TESTS INCLUDE IN THIS CONTRACT. 21. CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS (DOORS) AS REQUIRED BY THE MECHANICAL AIR CONDITIONIN6 SYSTEM AND BY OTHER REQUIREMENTS (WHERE ACCESS PANELS OCCUR AT ONE- HOURCONSTRUCTiON, CONTRACTOR SHALL PROVIDE SELF -CLOSING DEVICE AND ASSEMBLIES AS REQUIRED BY THE 6OVERNIN& CODE. ' 22. FINAL HOOK-UP AND CONNECTIONS OF ALL EQUIPMENTS, FURNITURE 5Y5TEM5, ETC. BY OTHERS SHALL BE INCLUDED IN THE 6ENERAL CONTRACT, 25. THESE CONSTRUCTION DOCUMENTS INDICATE ALL CRITICAL DIMENSIONS INVOLVED AND SHOULD NOT BE SCALED TO OBTAIN ANY CRITICAL DIMENSIONS. ALL DIMENSIONS INDICATED SHALL HAVE PREFERENCE OVER SCALE. 24. FIELD UNDERCUT ALL DOORS AS REQUIRED, APPROXIMATELY 3/4" FOR CARPET AND 1/4" FOR TILE:. 25, ALL DOORS SHALL BE LOCATED 4" FROM DAYLIGHT OF DOOR TO ADJACENT WALL UNLESS OTHERWISE NOTED. 26. ALL GLUE DOWN CARPET SHOULD BE INSTALLED TIGHT TO FINISH WALL. 21. NALLCOVERINCP TO BE CONTINUED TO THE FINISH FLOOR, UNLESS OTHERWISE NOTED. 2a. ALL WALL5 TO BE TAPED AND 5ANDE P SMOOTH TO FINISHED FLOOR. 241. WHERE NEW PARTITIONS ABUTT, JOiN OR CONNECT TO EXISTIN6 WALLS OR NEW CONSTRUCTION, THE FIN15HED SURFACES WiLL BE ALIGNED FLUSH. THE JOINTS SHALL BE TAPED AND SANDED SMOOTH To MEET REQUIREMENTS, 50. FIRE SPRINKLER CONTRACTOR SHALL PREPARE DETAILED DRAWINGS OF SYSTEM FOR ALL OF THIS CONTRACT AND SHALL SECURE APPROVAL OF THE BUILDIN6 DEPARTMENT AND JB CONCEPT PRIOR TO THE START OF INSTALLATION. LOCATION OF HEADS SHALL PROVIDE A UNIFORM CEILING PATTERN ACCEPTABLE TO THE DESIGNER WITH FULL CONSIDERATION TO ALL ELEMENTS OF CEILING" SUCH AS LiGHTS, HVAG, OUTLETS, ELEVATION CHANGES ETC. ALL WORK SHALL COMPLY WITH THE NATIONAL MECHANICAL CODES, 51, MECHANICAL AND ELECTRICAL CONTRACTORS SHALL PROVIDE SHOP DRAWINGS TO JB CONCEPT FOR REVIEW. 52. GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE LAYOUT AND EXACT LOCATION OF ALL PARTiTiONIN6, DOORS, ELECTRICAL/TELEPHONE OUTLETS AND LIGHT SNITCHES IN ACCORDANCE WiTH THE PLAN BEFORE PROCEEDING KITH CONSTRUCTION, 55. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTIN6 ANY DEFECTS FOUND IN EXISTIN6 BASE BUILDING CONSTRUCTION. THIS INCLUDES, BUT 15 NOT LIMITED TO UNEVEN SURFACES AND FINISHES AT PLASTER OR GYPSUM BOARD. THE GENERAL CONTRACTOR SHALL PATCH AND REPAIR SURFACES TO MATCH ADJACENT ADJOINING SURFACES. 34. "TYP." MEANS IDENTICAL FOR ALL SIMILAR CONDITIONS U.O.N. 35. "SIM." MEANS COMPARABLE CHARACTER15TIC5 FOR THE ELEVATION NOTED VERIFY DiMEN510N5 AND ORIENTATION ON PLAN. $6, ALL HARDWARE SHALL COMPLY Y41TH HANDICAP CODE REQUIREMENTS. 1. THE CONTRACTOR SHALL PROVIDE LINE AND GRADING ON THE FINISHED SLAB FOR ALL PARTITIONS, TO BE APPROVED BY JS CONCEPT (LINE AND 6RADiN& SHALL BE SHOWN BY PAINTING PARTITION LOCATIONS 0R BY INSTALLING METAL STUD FLOOR CHANNEL) 2.3 THERE SHALL BE NO HORIZONTAL JOINTS ON EXPOSED 5URFACE5 OF OP GYPSUM BOARD WALLS. S. ALL NEW WALLS ARE TO BE TAPED AND ARE TO APPEAR HOMOGENEOUS Y41TH EXISTING CONSTRUCTION WHEN COMPLETED. 4. CONTRACTOR SHALL PROVIDE SUFFICIENT FRAMING FOR ALL O ENIN65 FOR DUCT WORK AND RETURN AIR GRILLE OPENiN65 ABOVE A D BELOW HUNG CEILIN65. THESE ARE TO COORDINATE WITH THE AIR O(PNDITIONIN6 ENGINEER'S AND MECHANICAL GONTRAGT'OR'S SHOP Vf,AININOS. ALL OPENiN65 SHALL BEE PROPERLY SEALED FOR FIRE PR.00FIN6, SOUNOPROOFIN& AND VIBRATION CONTROL. 5. O.C. IS TO PROVIDE METAL GORNER BEADS AT ALL OUTSIDE CO RNERS AT DRYWALL PARTITIONS WITH A FINISH FREE OF DISTORTIONS. ON E TERIOR COLUMNS PA55 6YP5UM BOARD OVER COLUMN FACE WHERE, DRYWALL ABUT5 COLUMNS. 6.WHERE NEW PARTITIONS MEET NINOOW MULLIONS OR PERIMETER COLUMNS A SOUNDPROOF FILLER PANEL SHALL BE USED INSIDE THE CONVECTOR ENCLOSURE OR INSTALLED BETWEEN THE COLUMNS AND PERIMETER WINDOW MULLIONS. -7.IWHEN PATCHING DRYWALL PARTITIONS WHERE EXISTIN6 SURFACES DO NOT ALIGN IN THE SAME PLANE PATCH OUT ENTIRE SURFACE AS R QUIRED FOR AN EVEN, FLUSH SURFACE ON THE ENTIRE: WALL. 6.16.C. 15 TO PROVIDE APPROPRIATE BACKIN6 WITHIN NEW a EXI5TIN& WALLS FOR ALL HUNG CABINETS, SHELVING AND MILINORRK AS REQUIRED F R ADEQUATE SUPPORT. q. FOR SLAB TO SLAB PARTITIONS ALL JOINTS OGCURING ABOVE THE CEILING LiNE ON BOTH SIDES OF PARTITION 5HALL BE TAPED AND MUDDED WITH AT LEAST ONE GOAT OF COMPOUND (TYP) lO. 6.C. IS TO PLASTER / PATCH, FOR ALL TRADES REQUIRED. I1. TWO (2) DIA60NAL BRACES TO SLAB ABOVE SHALL BE PROVIDED AT DOOR OPENiNOS, AND TRIMMED OPENIN65, IF PARTITIONS ARE TO UNDERSIDE OF THE GEILIN6, PROVIDE: METAL BRAGIN6 AND APPROPRIATE STIFFENING TO SECURE CEILING 1116K PARTITIONS. - PROViDE STIFFENER AT EACH DOOR STRIKE AND AT FOUR FEET CENTERS (TYP)' 12. NOTE ALL HOLLOW METAL DOOR FRAMES SHALL BE 166A. AND SHALL BE WELDED AND PROPERLY FIRE RATED AND LABELED WITH U.L. LISTING (TYPICAL), U.N.O. 15.'ALL FIRE RATED DOORS SHALL BE PROPERLY LABELED WITH U.Li. LISTIN6. 14! ALL METAL STUD AN12 DRYWALL PARTITIONS 5UPPORTIN6 5UILT-1N MILLWORK AND OR CABINET WORK SHALL HAVE STUD SPACING OF l6'! O.C. IN LIEU OF:24" O.C: INCLUDING ALL REWIRED BRAGIN6, BLOCKING AND &ROUNDS. (TYPICAL) . 15.'1 ALL WOOD UTILIZED IN CONSTRUCTION SHALL BE FACTORY TREATED APPROVED BY THE DEPARTMENT OF BUILDINGS HAVING JURISDICTION. OVER THIS PROJECT. 16.1 UNLESS OTHERWISENOTEV ALL HARDWARE SHALL BE SUPPLIED BY THE GENERAL CONTRACTOR. 11 i ALL LOOK SETS SHALL BE CODED AND/OR KEYED IN ACCORDANCE NI I H THE BUILDING REQUIREMENTS. GORES AND/OR KEYS ARE TO BE DELIVERED TO THE TENANT PROPERLY TESTED AND/OR TAGGED. PROVIDE (3) MASTER KEYS AND (3) PASS KEYS FOR EACH, LOCK. 15,` G.C. 15 TO FURNISH AND INSTALL ALL ROUGH PLUMBING AND HOOK-UP FOR SINK, COFFEE MACHINE ICE MAKER AND REFRIGERATOR, AND INSTALL ALL FIXTURES (APPLIANCES) 141.G.C. WILL CLEAN AND PREPARE FLOOR FOR TILE INSTALLATION. AD DITI L NOTES I 11 L SOME CHANCvEES AND ALTERATION 15 PLANNED FOR THE MECHANICAL 5Y5Tf 2. VERIFY THE TOTAL OF 45 5.F.. RETURN AIR OPENIN65 EXIST WITH FUSIBLE LINK FIRE DAMPER IF WIRED . 5. GENERAL CONTRACTOR TO SUBMIT AIR BALANCE REPORT ( D*'r LL'S TEST 4 BALANCE CONTRACTOR) TO ON -SITE .OPERATING MANAGER WITHIN (15 ) DAYS AFTER STORE OPENING AND OCCUPIED. 4. 6ENERAL CONTRACTOR TO VERIFY FIRE DAMPER iN RETURN AIR DUCT. 5. VERIFY TEMP1,ASTER TYPE "S" VAV BOX THE:RMOSTST TYPE "ES-11" 6. LESS THAN OR F.QUAL, TO 6 FEET OF FLEX DUCT l5 ALL oINED. -i. G.C, TO VERIFY EXISTINGv EXHAUST FAN AND EVALUATE FOR RE -USE. S. G.C. TO VERIFY EXISTING "51MPLEX SMOKE: DETECTOR AND CO-ORDINATE KITH OPERATING MANAGER. 41. TENANT SHALL SUBMIT COPY OF THE HVAG :MAINTENANCE AGREEMENT TO ON', SITE OPERATING MANAGER.' 10. �TENANT MUST COMPLY KITH TITLE IIi OF THE: AMERICANS WITH THE DISABILITIES ACT ADA AND ALL LOCAL 8 STATES CODES. ll. PLAS. LAM, ON STOREFRONT 15 NOT PERMITTED, LAMINATE: 05ED INSIDE THE STORE MUST BE EITHER SOLICORE OR COLORCORE: TYPE 4F SOLID CORE 15 CHOSEN. . 12. STOREFRONT CANNOT BE SUSPENDED OR SUPPORTED FROM LANDLORD'S BULKHEAD STOREFRONT MUST BE FLOOR SUPPORTED i3. ALL DEM151N6 WALLS TO BE FURRED INITH 5/8" THK. GYP. 50ARD SLAB TO ! ROOF DECK 14. Cv.C. TO SEAL ALL STRUC,TURASL SHAPES, DUCTS, PENETRATIONS THROUGH THE DEM151NG INALL AIRTIGHT. 15. FLAME SPREAD RATING OF ALL FINISH MATERIALS A5 A5 PER UBC TABLE # 8-B 16. G.C. TO NOT CHANNEL SLAB ON UPPER LEVEL, GORE DRILL ONLY. 11. G.C. SHALL DEPOSIT INITH THE LANDLORD'S OPERATING MANAGER NITHOUT LIABILITY FOR INTEREST THE SUM OF $ THIS DEPOSIT WILL BE APPLIED TOAARD COSTS INCURRED BY LANDLORD TO COMPLETE TENANT'S WORK INkICH TENANT OR TENANT'S CONTRACTOR FAILS TO COMPLETE: WITHIN (50) DAYS AFTER THE PINK LiST i5 RECEIVED E3Y TENANT. Ia. ;PROVIDE NATER METER, VERIFY LOCATION WITH BUILDING MANAGER. IF. NO FREE: STANDING SECURITY DEVICES. I . 20. PROVIDE FLOOR DRAIN WITH CLEANOUT HOT WATER -HEATER MUST BE PIPED TO NEAREST DRAIN, 21. ANY PENETRATIONS OR MODIFICATIONS TO STRUCTURAL STEEL OR CONCRETE MUST BE CO-ORDINATED WITH ON -SITE OPERATING MANAGER. 22. 000 BLOCKING, DECKINC, AND FRAMING 15 ALLOWW ALLOWED ONLY BELO CE LING LINE AND iF iT'S MILLED STAMPED FIRE RETARDANT. 25, ALL RAISED PLATFORMS MUST BE CONSTRUCTED OF N0N-COM5U5TI$LE . MATERIALS. FIRE DEPARTMENT N, T 1. EXIT. DOORS SHALT. BE OPENABLE FROM THE iN51DE NITHOUT THE U5E OF A KEY OR ANY SPECIAL KNONLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. SUCH DOORS SHALL BE SELF CLOSING, 2, EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SEERVING"ANY HAZARDOU5 AREA OR WHEN 5ERVIN6 AN OCCUPANT LOAD OF 50 OR MORE PERSONS. 3. PANIC HAROIARE SHALL BE PROVIDED ON EXIT DOORS SERVIN6 ROOMS, CORRIDORS OR STAIRWAYS HANDLING AN OCCUPANT CAPACITY OF 50 OR MORE ,PERSONS. (CHAPTER 33 U.B.C.) : . 1 , 4. ALL DOOR HARDWARE SHALL COMPLY WITH THE STATE Or CALIFORNIA TITLE 24 ARCHITECTURAL BARRIERS LAW. 5. EXIT SIGNS SEC. 5N4 caTE:XI,T 5IONS SHALL BE INSTALLED AT REQUIRED EXIT DOORWAYS AND WHERE OTHERWISE NECESSARY To CLEARLY INDICATE THE DIRECTION OF EGRESS NHEN THE EXIT SERVES AN OCCUPANT LOAD OF 50 OR MORE. EXCEPTIONS: MAIN EXTERIOR EXIT DOORS WHICH OBVIOUSLY AND CLEARLY ARE IDENTIFIABLE AS EXITS NEED.NOT BE 51&NED WHEN APPROVED BY THE BUILDING OFFICIAL. (i2) GRAPHICS: THE COLOR AND DESIGN OF LETTERING, ARROWS AND OTHER SYMBOLS ON EXIT SIGNS SHALL BE iN H16H CONTRAST WITH THEIR BACK- 6RQUND, WORD5 ON THE SIGN SHALL BE iN BLOCK LETTERS 6" IN HEIGHT WITH A STROKE OF NOT LESS THAN 5/4". (c) ILLUMINATION. SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED BY TWO ELECTRIC LAMPS OR SHALL BE OF AN APPROVED SELF -LUMINOUS TYPE, WHEN THE LUMINANCE ON THE FACE OF AN EXIT SIGN 15 FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5.0 FOOTCANDLES FROM EITHER LAMP. INTERNALLY ILLUMINATED 516NS SHALL PROVIDE.EQUIVALENT LUMiNACE. 11 6. DOORS OPENIN6 INTO REQUIRED (I) ONE-HR FIRE RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A SMOKE: OR DRAFT STOP FiRE ASSEMBLY HAVING (20) MINUTE RATING INCLUDING HAVING SIMILARLY LABELED FRAMES. 1. PORTABLE FiRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A TO BE PROVIDED WITHIN '75 FEET TRAVELING DISTANCE OF ANY POINT IN THE SPACE. S. DRAPE5 AND OTHER DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. CERTIFICATION THEREOF SHALL BE PROVIDED, EXITS, EXIT L16HTS, FIRE ALARM STATIONS, HOSE cABINETS AND EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED BY DECORATIVE MATERIAL, [i. INTERIOR FINISHES SHALL CONFORM WITH TITLE Iq, SECTION 2-4264, CAC AND AS PER UBG TABLE # 6-5 10, CEILIN6 TILES TO BE MINERAL TILES WITH U.L. LABEL AND WITH .FLAME FLAME SPREAD RATING OF 25 OR LESS. i1. ALL A15LE5 TO REQUIRED EXITS SHALL BE A MIN. 44" IN WIDTH. 12. MAIN ENTRY DOORS SHALL HAVE A DURABLE SIGN OF W) ONE -INCH HIGH INCH LETTERS ON A CONTRA5TIN6 BACK&ROUND'MOUNTED ON THE FIXED HEADRAIL STATIN6: 'THIS DOOR..." OR 'THESE DOORS TO REMAIN UNLOCKED DURING BUSINESS,HOURS," THE LOCKING DEVICE MUST BE OF A, TYPE THAT 11 WILL BE READILY D15TINOUISHA5LE AS BEIN6 LOCKED. 15. EXTEND OR MODIFY THE BUILDING FIRE / LIFE SAFETY SYSTEM AS TO MEET CODE REQUIREMENTS. I . 14. PROVIDE AN APPROVED FIRE 5PRINKLER SYSTEM. SUBMIT PLANS FOR APPROVAL PRIOR TO INSTALLATION. (FIRE CODE SECTION #2.101) 15. PROVIDE AN APPROVED I HR, FiRE RESISTIVE CORRIDOR FOR MULTIPLE TENANT FLOORS. (B.G. S3305 OR TITLE 24 55504). IF APPLICABLE 16. MODIFY EXISTIN6 AUTOMATIC FIRE EXSTINGUISHING SYSTEM, AS NEEDED TO BE APPROVED BY BUILDING AND SAFETY PLUMBIN6. DIVISION PRIOR TO INSTALLATION. (L.A.M.C, 51.15a) I'1. FIRE DEPARTMENT FINAL INSPECTION REQUIRED. SCHEDULE INSPECTION TWO DAY iN ADVANCE. TEL. Ia. LOCATIONS 8 CLASSIFICATIONS OF FIRE EXTIN6USHER5 TO BE DETERMINED BY FiRE INSPECTOR. Ig. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE 8 COMBUSTIBLE LIQUIDS, FLAMMABLE 4 COMPRESSED GASSES 4 OTHER HAZARDOUS MATERIALS SHALL COMPLY WITH UNIFORM FIRE CODE RE6ULATIONS. 20, BUiLDIN&(S) NOT APPROVED FOR HIGH PILED COMBUSTIBLE STORAGE. MATERIALS IN CLOSELY PACKED PILES SHALL NOT EXCEED 15 FEET IN HEIGHT, IN HE16HT, 12 FEET ON PALLETS OR IN RACKS 4 6 FEET FOR TIRES, PLASTICS & SOME FLAMMABLE LIQUIDS, IF HiOH STOCK PILING, COMPLY WITH U.F.C., ART.SI.4 N.F.P.A. STD. 251, 231C 4 23ID. 21. PLANS OF MOD'IFICATION5 TO OR NEW FIRE PROTECTION, DETECTOR OR ALARM SYSTEM(5) SHALL BE APPROVED BY THE FIRE DEPARTMENT PRIOR TO INSTALLATION. 22. APPROVED APPLIANCES SHALL BE STATE FIRE MARSHALL APPROVED SEC. '1203(6), AND INSTALLED iN ACCORDANCE KITH THE PROVISIONS OF NFPA '726 SEC. 6004(1) IN ALL CODE SPECIFIED AREAS. i. CODE SPECIFIED AREAS. 25. FiRE: DEPARTMENT PLAN CHECK AND ELECTRICAL PERMITS ARE REQUIRED PRIOR TO THE INSTALLATION OF ANY VISUAL NOTIFICATION APPLIANCES. I SPRINKLER NOTES I.. SEE ENGINEERIN6 DRAWiNC-,5 FOR LOCATION OF HEADS, BRANCH PIPING, ETC. AND ALL AORK REQUIRED TO COMPLETE TH15 PROJECT. SUBMIT PLANS TO CHIEF BUILDIN6 ENGINEER AND OBTAIN HIS REVIEW PRIOR TO COMMENCEMENT OF ANY SPRINKLER WORK. 2. 64,. SHALL COORDINATE AND ARRANGE FOR DRAINING AND REACTIVATION OF EXI5TiN0 SPRINKLER 5Y5TE:MS Y41TH BUILDIN6 MANAGEMENT, AS REQUIRED. S. G.C. SHALL BE RESPONSIBLE FOR TEMPORARY FIRE WATCH AND ALL PROTECTIVE MEASURES REQUIRED BY BUILDIN6 MANAGEMENT WHEN SYSTEM IS MADE INACTIVE TO ACGOMODATE MS MANA6E:MENTSPRINKLER WORK. 4. 6.C. SHALL BE RESPONSIBLE FOR ALL FINAL 'PESTS- AND INSPECTIONS OF COMPLETED WORK REQUIRED BY THE BUILDIN6 MANAGEMENT PRIOR TO occuPANGY OF SPACE. , S. ALL SPRINKLER WORK SHALL BE TESTED AND MADE OPERATIONAL PRIOR TO SBS CARPET AND FURNITURE INSTALLATION. G.C, SHALL REPAIR AND REPLACE ALL, FINISHES DAMAGED BY DEFECTIVE SPRINKLER WORK, AT HIS EXPENSE. 6. G.C. SHALL PROPERLY TEST AND INSPECT EXISTING SPRINKLER SYSTEM PRIOR TO COMMENCEMENT OF WORK, AND SHALL NOTIFY LANDLORD AND JB CONCEPT IMMEDIATELY IF REPAIR WORK OF EEXi5TING SPRINKLER SYSTEM 15 REQUIRED. -7. ALL BURNING, CUTTING, SOLDERING AND NELDIN6 SHALL BE COORDINATED KITH BUILDING MANAGEMENT PRIOR TO COMMENCEMENT OF NORK. 5. 6.C. SHALL COORWINATE ARRANGEMENTS FOR TEMPORARY DISCONNECT AND RECONNECT OF FIRE SYSTEMS W1TH BUILDING BUILDING MANAGEMENT. a, 6.C. 5HALL BERESPONSIBLE FOR OBTAINING PERMITS AND APPROVALS REQUIRED BY BUILDING INSPECTORS AND FIRE MARSHALL IN CONJUNCTION WITH CHANGES To. EXISTIN6 SPRINKLER SYSTEM. 10. ALL SPRINKLER HEADS (BUILDIN(5STANDARD TYPE) SHALL BE INSTALLED iN THE CENTER OF GEILIN6 GRID. ANY DEVIATION TO THiS NOTE MUST BE REViENED KITH JB CONCEPT PRIOR TO PROCEEDING AITH NORK I. EXCEPT IN CUSTOMER SALES AREA ,FLOORS SHALL BE SMOOTH AND IMPERVIOUS WATER ,6RE:ASE ,ACID ,AND OF EASILY GLEANABLE CONSTRUCTION. FLOOR SURFACES IN ALL AREAS WHERE FOOD 15 PREPARED ,PAGKA6ED,OR 5TORE:D,INHERIF ANY UTENSIL 15 WASHED ,WHERE REFUSE OR GARBAGE 15 STORED WHERE JANITORIAL FACILITIES ARE LOCATED ,IN ALL TOILET AND HAND104ASHIN6 AREAS AND IN EMPLOYEE CHANGE AND 5TORA&E AREAS, SHALL BE AN APPROVED TYPE THAT CONTINUES UP THE WALL5 OR TOE -KICKS, AT LEAST 4" IN A 5EAMLE55 MANNER, FORMING A 3/6" MIN.RADIUS COVE AS AN INTEGRAL UNIT. 2. WHERE SLIP RESISTANT FLOORS OR EXCESSIVE MOISTURE MAY ACCUMULATE, FLOOR DRAIN MAY BE REQUIRED. ALL FLOOR TO BE SLOPED TO THE FLOOR DRAIN, SHEET VIINYL FLOORING 15 GENERALLY NOT ACCEPTED WHEN FLOOR DRAINS ARE UTILIZED 3. FLOORING UNDER EQUIPMENT AND ON THE COVED BASES SHALL BE COMPLETELY SMOOTH . FLOOR SURFACES N1CH CONTAIN SLIP RESISTANT A6ENT5 SHALL BE RESTRICTED TO TRAFFIC AREAS ONLY. 4. ALL DUCTS AND EXHAUST OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH CHAPTER 20 OF THE CURRENT EDITION OF THE UNiC AS ADOPTED BY THE LOCAL BUILDIN6 DEPARTMENT. 5. ALL JOINTS AND SEAMS SHALL BE TIGHT OR SOLDERED FOR EASE OF CLEANIN6 . RiETED SEAMS ARE NOT ACCEPTED. 6. ALL REFRIGERATION UNITS SHALL BE ADEQUATE IN CAPACITY TO THE NEEDS OF THE PROPOSED OPERATION AND SHALL COMPLY Y41TH THE FOLLONIN6 : A. BE CAPABLE OF OPERATING 50 AS TO MAINTAIN THE REFRIGERATED FOODS AT OR BELOW 45 F AT ALL TIMES. B. BE SPECIFICALLY CONSTRUCTED FOR COMMERCIAL USE C. BE PROVIDE WITH AN ACCURATE, READILY VISIBLE THERMOMETER D. HAVE: SHELVING THAT 15 NONA55ORSENT AND EASILY CLEANABLE. 1. WHERE MULTISERVICE KITCHEN UTENSILS ARE UTILIZED THERE SHALL BE PROVIDED LEAST A TWO COMPARTMENT STAINLESS STEEL SINK WITH DUAL, INTEGRALLY INSTALLED STAINLESS STEEL DRAINDOAR05 . 6. A SEPERATE , APPROVED TWO COPARTMENT SINK MUST BE INSTALLED WITHIN EACH DEPARTMENT IN A 6ROGERY STORE, DELI, MEAT, BAKERY SUSHI BARS OYSTER BARS THE MIN. COMPARTMENT 51ZE SHALL BE AT LEAST l8"X l8"X 12" DEEP WITH MIN, 15"X IP" DRAINBORDS.. WHEN A SINK 15 INSTALLED NEXT TO A WALL, A METAL 5ACK5PLASH EXTENDING UP THE WALL AT LEAST a" SHALL BE FORMED AS AN INTEGRAL PART OF THE SINK AND SEALED TO THE WALL. R. DISPLAYS OF UNPACKAOED FOOD5 SHALL BE SHIELDED 50 AS TO INTERCEPT A DIRECT LiNE BETINEEN THE CUSTOMER'S MOUTH AND THE FOOD BEING DISPLAYED 10. ADEQUATE FLOOR SPACE AND WALL SHELVES SHALL BE PROVIDED FOR THE STORAGE OF FOOD .AT LEAST 32 L.F OF APPROVED SHELVING UNITS SHALL BE INSTALLED . II. A DESIGNATED AREA MAY BE SUBSTITUTED FOR A CHANGE ROOM IF THE FACILITY IF THE FACILITY HAS LE55 THAN 5 EMPLOYEES PER SHIFT.THE DEa16NATED AREA MUST BE PHYSICALLY 5EE6REEGATEED FROM TOILET ROOMS , FOOD PREPARATION AREAS AND UTENSIL AREAS BY APPROVED PARTITIONS .WITHIN THE DESIGNATED AREA ONE LOCKER 12"X iWX 56" PER EMPLOYEE ON A 61VEN SHIFT MUST BE: PROVIDED. 12. ALL SHON AND DISPLAY CASES, COUNTERS, SHELVES, TABLE, REFRIGERATION E:QUIPMENT,SINK5 AND OTHER EQUIPMENT USED IN CONNECTION WITH THE PREPARATION, SERVICE AND DISPLAY OF FOOD, SHALL BE MADE OF NONTOXIC MATERIALS AND 50 GON5TRUGTED AND INSTALLED AS TO BE EASILY CLEANABLE. 15. ALL LIQUID WASTE, INCLUDING SEWAGE'., 6ENEERATE V BY A FOOD FACILITY SHALL BE OISPOSEP OF IN AN APPROVED MANNER INTO EITHER A PUBLIC SEWER SYSTEM OR TO AN APPROVED PRIVATE ON SITE SEWAGE DISPOSAL SYSTEM. 14. ALL PLUMBING AND PLUMBING FIXTURES SHALL BE INSTALLED IN COMPLIANCE WITH LOCAL PLUMBIN& ORDINANCES, SHALL SE MAINTENED 50 A5 TO PREVENT ANY CONTAMINATION, SHALL BE KEPT CLEAN, SHALL BE FULLY OPERATIVE, AND SHALL BE IN GOOD REPAIR. 15. AN AREA SHALL SE PROVIDED FOR THE STORAGE OF &ARBA6E AND TRASH CONTAINERS, WALL5, FLOORS, AND CEILING OF SUCH ROOM OR AREA SHALL BE SMOOTH AND EASILY GLEANABLE. lb, ALL DELIVERY DOORS LEADING TO THE OUTSIDE SHALL BE SELF CLOSING. LARGE CARGO TYPE DOOR SHALL NOT OPEN DIRECTLY INTO FOOD PREP AREA I"!. OPENIN69 AT BASE AND SIDE OF EXTERIOR DOOR SHALL NOT EXCEED 1/4" ALL EXTERIOR WALLS PIPE OR OTHER OPENING5 SHALL BE TIGHTLY SEALED . ALL EXTERIOR WALL VENTS SHALL BE PROPERLY SCREENED WITH 1/4" HARDWARE CLOTH SCREENING. 15. THE APPROVAL OF THE HEALTH DEPARTMENT 15 REQUIRED BEFORE: THE INSTALLATION OF ANY FOOD HANDLING EQUIPMENT AND BEFORE 5E61NING OPERATION ALLOW -72 HOURS FOR INSPECTION, ANY ADDITIONAL REQUIREMENTS ARE 5UBJEGT TO ON SITE INSPECTION. . icl. 6ENERAL CONTRACTOR SHALL REVIEN ALL TRADE FIXTURE CONTRACTORS DRANIN65 TO VERIFY THERR 5GOPE OF WORK. 20. ALL ENCLOSED PORTIONS USED BY HUMAN BEIN6 AND ALL LOOKER ROOM SHALL BE PROVIDED WITH ARTIFICIAL L16HT AND MECHANICALLY OPERATED VENTILATING SYSTEM SHALL SUPPLY A MINIMUM OF 5 CFM OF OUTSIDE Alp, KITH A TOTAL CIRCULATION OF NOT LESS THAN 15 CFM PER OCCUPANT IN ALL PORTIONS OF THE BUILDIN6 AND SUCH SYSTEM SHALL BE KEPT CONTINUOUSLY IN OPERATION DURING SUCH TIME AS THE BUILDING 15 OCCUPIED. 21, EACH TOILET ROOM SHALL BE VENTILATED TO PROVIDE A cOMPLETE AIR CHANGE EVERY 15 MINUTES. 22. SEAL ALL EQUIPMENTS TO THE WALL (CABINE:T5 OR OTHER PERMANENT ADJACENT EQUIPMENT OR MOVE ANAY FROM WALL 6" FOR EVERY 4 FEET OF LINEAL FOOTAGE. 11 FL11 1i 1. HAND ACTIVATED DOOR OPENING HARDWARE TO BE MOUNTED 50" TO 44" ABOVE THE FLOOR AND BE OPERABLE WITH A 5IN6LE EFFORT BY LEVER TYPE HARDINARE. 2. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED b.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS. 3. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC,) SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE. 2-3303(m) 4. ALL REQUIRED EXIT DOORWAYS SHALL HAVE A MINIMUM 52" CLEAR OPENING INITH THE DOOR AT 410 DE&REFS TO THE CLOSED POSITION. 5. MAXIMUM HE16HT OF THRESHOLD TO BE 1/2". MAXIMUM VERTICAL CHANGE AT EDGE 15 1/2" INITH A MAXIMUM BEVEL OF 45 DE61REES. 6. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY HANDICAPPED PERSONS. THE SIGN TO BEE MOUNTED 60" ABOVE FINISHED FLOOR. '1. THE AREA OF NORK COVERED BY THIS PERMIT AND AT LEAST ONE: PATH OF TRAVEL TO THE AREA OF WORK SHALL COMPLY INITH TITLE 24. 8. BATHROOMS, PUBLIC TELEPHONES AND DRINKING FOUNTAINS 5ERVIN& THE AREA OF NORK COVERED BY THIS PERMIT SHALL COMPLY WITH TITLE 24 DISABLED ACCESS COMMERCIAL PLAN REQUIREMENTS. cf. IF EMERGENCY NARNIN6 SYSTEMS ARE REQUIRED, THEY SHALL ACTIVATE A MEANS OF NARNIN6 THE: HEARING IMPAIRED. 1. THE G.G. SHALL PROVIDE ALL HEATING, VENTILATION AND AIR CONDITIONING NORK AS GALLED FOR AND 5PECIFIED BY THE CONTRACT ENGINEERIN6 DOCUMENTS AND DRAWINGS. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD SUPERVISION OF ALL HVAG WORK DURING INSTALLATION AND SHALL INSPECT ALL SYSTEMS FOR PROPER OPERATION AT COMPLETION OF THE JOB. 3. SHOP DRANINC75 OF DUCTWORK AND RE615TER5 INCLUDING ACCE55 PANELS IF REQUIRED SHALL BE SUBMITTED TO JB C+17 AND ENGINEER FOR APPROVAL PRIOR TO PROCEEDIN6 WITH FABRICATION AND/OR INSTALLATION OR RELOCATION. 4. AIR CONDITIONING SYSTEM THROUGHOUT ENTIRE SPACE 15 TO BE PROPERLY BALANCED AFTER MOVE IN. AIR BALANCE SHALL BE PERFORMED BY AN INDEPENDENT AIR BALANCE CONTRACTOR WHO SHALL CERTIFY THAT THE REPORT 15 ACCURATE. SUBMIT 2 COPIES TO LANDLORD. 5. HVAG CONTRACTOR TO REFER TO REFLECTED GEILIN6 AND FURNITURE DRAWIN65 FOR OCCUPANCY FIGURES AND HEAT PRODUCiN6 EQUIPMENT. 6. INSTALLATION SHALL BE COORDINATED Y41TH ALL TRADES AS REQUIRED FOR PROVE ASSEMBLY. CEILING DIFFUSERS TO BE RELOCATED TO MAINTAIN NEW FIXTURE PATTERNS IF REQUIRED. 1. INTERIOR SPACES. SHALL BE MECHANICALLY VENTILLATED IN ACCORDANCE WITH THE ADMINISTRATIVE GORE. PLANS SHOWIN6 MECHANICAL VENTiLLATION SYSTEM WILL BE FILED IN ACCORDANCE WiTH THE RULES OF THE DEPARTMENT OF BUILDINGS. a. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL POWER AND CONTROL WIRING REQUIRED FOR THE HVAG SYSTEM. 41. ANY 51)ILDIN6 SHUT DOWNS REQUIRED FOR THIS WORK SHALL BE ADDVANCE of TTHE 1 SHUTTY0O)NN. CONTRACTOR. ECONTRACTORRE SHALL HOURS AUTHORITIES HAVING JURISDICTION PRIOR TO SHUT DOWN, ANY SHUTDOWN AFFEGTIN6 THE NORMAL HVAG SERVICE OF OTHER BUILDING OCCUPANTS SHALL BE DONE ON OVERTIME. 10. ALL OUTSIDE LOUVERS SHALL MATCH EXI5TiNO AND 5KETCHES SHALL BE SUBMITTED TO BUILDING FOR APPROVAL PRIOR TO INSTALLATION. NO OUTSIDE LOUVER OR DUCTWORK 15 TO BE INSTALLED IN SUCH A MANNER AS TO INTERFERE WITH THE CLEANIN6 OF WINDOWS OR REPLACEMENT OF GLASS AND WITHOUT BUILDIN6 APPROVAL. 11. PERIFERAL SHUT-OFF VALVES SHALL BE ACCESSABLE AT ALL TIMES. 12. AFTER COMPLETION OF ALL AIR CONDITIONING WORK, THE CONTRACTOR SHALL BALANCE ALL SYSTEMS AND SUBMIT DESIGN BALANCING FIGURES TO THE BUILDINO AFTER APPROVAL FROM THE DESIGN ENOINEER. SEE NOTE 4, ABOVE FOR ADDITIONAL REQUIREMENT5. 15. THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL PLUMBING ROUGH -IN, FIXTURES AND ACCESSORIES SHOWN ON ALL PLANS AND DETAIL DRAWINGS. :14. THE CONTRACTOR SHALL SUBMIT CUTS OF ALL FIXTURES, FITTINGS AND ACCESSORIES TO JB C+D FOR APPROVAL, 15. THE CONTRACTOR SHALL COORDINATE HIS PLUMBiNO WORK WITH MANUFACTURER'S SPECS. 16. ALL RISER SHUTDOWNS SHALL .BE SUPERVISED BY 5UILDIN6 A5 DIRECTED BY BUILDIN6 MANAGEMENT. NO WATER RiSERS SHALL BE SHUTDOWN DURING BUILDING OFFICE HOURS. 17. THE CONTRACTOR SHALL PLAN INSTALLATION OF NEW PLUMBING WORK AND CONNECTIONS TO EXISTING WORK TO INSURE MINIMUM INTERFERENCE WITH REOULAR OPERATIONS OF EXISTING FACILITIES. SUBMIT TO THE 5UIL1'-*1IN6 MANAGER A DATE: SCHEDULE FOR APPROVAL OF NECESSARY TEMPORARY 5HUTDONNS OF EXISTING SERVICES, ALL SHUTDOWNS SHALL BE MADE AT SUCH TIME AS WILL NOT INTERFERE WITH REE&ULAR OPERATION✓ OF EXISTIN& FACILITIES AND ONLY AFTER WRITTEN APPROVAL OF THE BUILDING MANA&ER. Ia. CONTRACTOR SHALL UPDATE EXISTING VALVE CHARTS AND USE: VALVE TA65 TO MATCH TH05E PRESENTLY IN USE. A. PROVIDE LEAD OR FIBER SHIELDS BETWEEN HANGERS AND CLAMPS FOR COPPER PLATE. 20. ALL PIPE HANGERS AND SUPPORT5 SHALL BE CONNECTED TO THE BUILDING 5TRUGTURE. NO CHAIN STRAPS, PERFORATED BARS, WIRE . HANGERS OR EXPANSION SHIELDS PERMITTED NO HANGING FROM WORK OF OTHER TRADE PERMITTED. 21. SLEEVES ARE TO BE PROVIDED FOR EACH PIPE PAS5ING THROUGH WALL5, PARTITIONS FLOORS AND SLABS. ALL PENETRATIONS OF RATED ASSEMBLIES SHALL BE FIRE STOPPED PER GORE. 22. ALL FIXTURES INSTALLED MUST HAVE A SHUTOFF VALVE AND NHERE TW0 OR MORE FIXTURES ARE iN THE SAME AREA A VALVE TO CONTROL ALL FIXTURES AS WELL A5 A SHUTOFF VALVE AT THE R15ER 50 THAT ANY FIXTURE(S) LINE OR PIECE: OF APPARATUS MAY BE CUTOFF FOR REPAIR WITHOUT INTERFERENCE OR INTERRUPTION OF THE SERVICE TO THE REST OF THE BUILDING. ALL VALVES SHALL BE DESIGNED FOR REPACKING AHEM HIDE OPEN UNDER PRESSURE. (A5 PER BUILDING STANDARDS) 25. THE CONTRACTOR SHALL COORDINATE PLUM5IN6 NORK Y41TH THAT OF ALL OTHER TRADES. 24. BEFORE BEING COVERED UP OR BUILT-IN ALL PIPING SHALL BE TESTED AS REQUIRED BY THE AUTHORITIE5 HAVIN& JURISDICTION. 25. PROVIDE LON CONSUMPTION NATER CLOSETS FOR ALL NEW CONSTRUCTION. EXI5TIN6 SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOIN WATER CONSUMPTION. I. CONTRACTOR SHALL NOTIFY JB C+D OF ANY P05615LE INTERFERENCES BEFORE PROCEEDING WITH INSTALLATION. 2. CEILIN& HEIGHTS SHALL BE P A.F.F. UNLESS OTHERINISE NOTED. ANY DEVIATION FROM THE HEI6HTS SHOWN WILL BE SUBMITTED TO JB C+D FOR REVIEW AND APPROVAL. 3. FASCIAS OR ANY BREAK IN THE CEILING HEIGHTS CREATED BY THE: INSTALLATION AND/OR ALTERATION OF HEATING, VENTILATING, AIR CONVITIONIN& OR MECHANICAL DUCTS, PIPING OR OTHER EQUIPMENT SHALL BE FORMED OF GYPSUM NALLBOARD ON FURRIN6 CHANNELS. ALL CONDITIONS TO BE APPROVED BY JB C+D 4. CEILINGS IN CL05E:TS SHALL BE OF THE SAME HEIGHTS AND CONSTRUCTION AS THAT OF ADJOINING SPACE, EXCEPT AS OTHERWISE NOTED. 5, THE G.C. SHALL CLOSELY COORDINATE THE CEILING NORK WITH THAT OF THE CABINET, PLUM5I46, HVAG, ELECTRICAL NORK AND THE TELEPHONE COMPANY NHEREVER THEIR RESPECTIVE NORK i5 CONTI60OL 6. THE O.G. SHALL COORDINATE TELEPHONE/516NAL CABLE INSTALLATION Y41TH TENANT'S COMMUNICATIONS CONTRACTOR PRIOR TO COMPLETION��OF }}CE:ILIN6 NORK. IN THE ,OraTIGAL NORiGOA51 REQUTI>D FOR IGTTINOSI'-FIXTURES PROVISIONS DIFFUSERS AND OTHER INSERTED ITEMS. , e. IN GENERAL, WITHIN EACH AREA, THE CEILING WORK REQUIREMENTS SHALL BE EXECUTED IN SUCH A MANNER AS TO PROVIDE A CONTINUOUS AND ALIGNING CEILING. THE FINAL CEILING INSTALLATION SHALL BE FREE OF ALL VISUAL DEFECTS. Of ALL CEILINGS SHALL BE CONSTRUCTED IN ACCORDANCE KITH LOCAL BUILDING CODES AND MANUFACTURERS SPECIFICATIONS. G.G. SHALL PROVIDE ALL NECESSARY LATERAL BRAGIN6 AS REQUIRED TO MEET PERTINENT LOCAL BUILDING GORES, INCLUDING COMPRESSION STRUTS IF REQUIRED BY CODE, 10. PROVIDE METAL BRACING AS REQUIRED FOR ALL MILLWORK ITEMS SECURED TO CEILING. a ♦ - .. i r A .. r « • " • GROUNDFLOOR 155VED FOR PRICING I 02114/05 ISSUED FOR PLAN CHECK 02/14/05 A ISSUED FOR CONSTRUCTION Approved DrOAMJ.B. Rovlorled J.B. Project No. Dwg.Fl16 A.O Scale Issue Date 1/26/05 ,►, 11J Shoot of wil r► �r • - rr roo- :.♦ 4" UNLESS OTHERWISE NOTED DOOR NOTES: 1. ALL DOORS TO BE UNDERCUT TO CLEAR FINISH FLOOR COVERING AND/OR THRESHOLD/ SADDLES SY 1/4" UNLESS OTHERWISE NOTED DOOR NUMBELg 2. S.C. SHALL FURNISH AND INSTALL ALL DOORS 4 DOOR TYPE 100 HARDWARE REQUIRED FOR A COMPLETE d PROPER AA INSTALLATION. SHOULD ANY ADDITIONAL ITEMS BE REQUIRED, THE S.C. SHALL ADVISE J.B CONCEPT+ DE: HDNRR. 6ROUP PRIOR TO ORDERING SAME. JB CONCEPT SHALL BE ADVISED IN A TIMELY MANNER SO THAT ANY OMITTED FRAME TY IDEN IFIED, O MAYPIN& ITEMS WE TDERE DULESTALLED S. ALL FINISH HARDWARE SHALL MEET ALL REQUIRMENTS OF STATE 4 LOCAL CODES. HARDWARE FOR USE ON RATED DOORS $ SHALL BE UL LISTED IN ACCORDANCE WITH NFPA-80 AND THE STATE FIRE MARSHALL. 4. ALL DOOR FRAMES TO BE BUILDING STANDARD AS LISTED IN PRODUCT SECTION 5. ALL DOORS SPECIFIED HEREIN SHALL BE FINISHED TO MATCH STAIN SAMPLES FURNISHED BY THE G.G.. DOORS TO BE FINISHED ON BOTH SIDES, HINGE d STRIKE EDGES 8 TOP d BOTTOM EE170ES SHALL BE UNFINISHED, A. 6. ALL ITEMS OF HARDWARE SHALL BE ORDERED ONLY WITH THE WRITTEN APPROVAL OF THE OE5IONER. SAMPLES OF ALL HARDWARE ITEMS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL `i. ALL NEW INTERIOR DOORS SHALL BE EQUIPPED WITH H.G. APPROVED LEVER TYPE HANDLES. FOR TYPICAL DOOR DETAILS SEE SHEET A. 6. ALL DOORS TO BE OPENABLE FROM INSIDE WITHOUT SPECIAL KNOWE76E SECOND EFFORT, q. TOILET ROOM DOOR TO BE EQUIPPED WITH OVERHEAD CLOSER WITH A MAXIMUM OF 5 LBS OPERATING FORGE. 10. EXTERIOR ENTRY DOOR SHALL BE LOCKABLE OLN1' FROM OUTSIDE OF STORE AND SHALL HAVE NO LOCKS OR LATCHES ON THE INSIDE OF THE DOOR 11. NO THUMB LATCHES OR KEYED CYLINDER BOLTS ARE ALLOWED ON ANY DOOR UNLESS OPERATED BY A SINGLE ACTION LEVER. 12. ALL NEW INTERIOR DOORS TO BE EQUIPPED WITH " TIMELY" FRAME, VERIFY ALL LOCKIN6 REQUIREMENTS W1TH OWNER, 15, DOORS IN ANY POSITION SHALL NOT REDUCE THE CORRIDOR WIDTH BY MORE THAN ONE HALF. POCKET DOOR DOOR DESCRIPTION TYPE A EXISTING BUILDING STANDARD GLASS STOREFRONT SINGLE ENTRY DOOR SIZE: 56" Nx i'-0" HT TEMPERED GLASS 10"HT KICK PLATE W/ BRONZE FINISH BY B NEW STAINLESS STEEL DOOR FINISH W/ DOUBLE SNIN6 AND GLASS VISIO LI&HT V-0" W x '1'-0" HT. BY C NEW INTERIOR POCKET DOOR Wl PLASTIC LAMINATE FINISH 110 NOTE: ALL TENANT DOORS SHALL SE FINISHED PER 6ENERAL NOTE ABOVE, TO MATCH SAMPLE PROVIDED BY G.G.. HDWR. DESCRIPTION GROUP EXISTING BLD6 STAND HARDWARE, ADJUSTABLE CLOSER, 10" KICK PLA A DOOR STOP, ALUMINUM THRESHOLD, HIN6ES AND LOCK B 5TAINLE55 STEEL PUSH PLATE AT BOTH SIDE OF THE DOOR, DOUBLE SWIN6 HIN6E, DOOR STOP AT EACH SIDE OF THE DOOR. C 1 UPPER TRACK, LOCK, ADA PULL HANDLE AND PRIVACY LOCK. 0 1� F FRAME DESCRIPTION TYPE I INTERIOR ALUMINUM FRAME BY "TIMELY" OR EQ. 2 INTERIOR ALUMINUM FRAME BY "TIMELY" OR EO FOR A POCKET DOOR 5 SYMBOL MATERIAL MANUFACTURER STYLE NUMBER COLOR REMARKS P 2 COATS OF PRIMER PAINT FR.AZEE 61q I W MADONNA LILY SEMI 61-055 FINISH PAINT LAURA ASHLEY 2 GOATS OF PRIMERSATIN 2 WV54015 BAKED CLAY FINISH TYPICAL 2 GOATS OF PRIMER PAINT LAURA ASHLEY Pll OLIVE 5 SATIN FINISH TYPICAL PAINT LAURA ASHLEY 6l6 SAGE 2 COATS OF PRIMER 4 SATIN FINISH P PAINT LAURA ASHLEY NV55011 GOLD COIN 2 COATS OF PRIMER 15ATIN FINISH FIBER GLASS IN PREP FOOD AREA R REINFORCED MARLITE OR EQ. 5-100-6 WHITE € ;Pgi1ESTER BYAI j THE 1TGaMPnRrzMirrEtNjN SINK �`ILL.iNORK FINISH L 767END YMBOJ MATERIAL MANUFACTURER NUMBER COLOR STYLE REMARKS PL I PLASTIC LAMINATE FORMICA 5a04-45 WILD CHERR GG TO PROVIDES PL ,FaOPPROVN�R $ DESI6NER. ME MELAMINE R055UR6 5355 BRENTWOOO MATTE 6C TO PROVIDE SAMPLE I PANEL CHERRY FOR OWNER $ OESI&NER APPROVAL TP THERMOPLASTIC ATI ADVANCED &LOBE &C TO PROVIDE SAMPLE SHEET T'EGHNOLO&Y INC., STAINLESS MIRROFLEX FOR OWNER $ DESIGNER APPROVAL TEL:600 4'70 5651 5/511 STAINLESS 5TAINLES5 STEEL FOR 5PLA5H FOR COUNTER FBIN€SK I STEEL 5 5/4 THK NATURAL, EMSER &1ALL0 BULL NOSED ED&E STONE SLAB VENEZIANO POLISHED 6G TO PROVIDE SAMPLE FOR OWNER 4 DESIGNER APPROVAL PART 1 T I CAN LI:�77ND SYMBOL DESCRIPTION F:::- EXISTIN6 NALLS/PARTITIONS TO REMAIN - - EXISTING WALLS/PARTITIONS TO BE REMOVED. r J EXISTING DOOR TO BE REMOVED , SALVAGED AND REUSED. F� ALIGN ARROW 1. ALL WALL TO BE PRIMED BEFORE PAINTING, PAINT TO BE AS REQUIRED FOR PROPER COVERAGE, MIN. OF TWO COATS. 2. PAINTED DOORS TO BE SEALED PLUS A MINIMUM OF TWO COAT5 OF PAINT OR MORE FOR PROPER GOVERA6E. 5. ALL FINISHES TO COMPLY WITH TABLE 42-5, U.B.C. 4. PRIOR TO INSTALLATION, CONTRACTOR TO PROVIDE '"JB C+D" WITH FINISH SAMPLES FOR THEIR APPROVAL. 5. WINDOW SILLS AND DOOR HEADERS TO BE EXAMINED BY 6.C. AND REPAIRED AS REQUIRED. I. USE 6" QUARRY' COVED BASE AT PREP AND SERVICE FOOD AREA 2. ALL BASE TO BE 6" HT 5TRAl6HT TILE AT PUBLIC AREA U.O.N. 3. PRIOR TO INSTALLATION, CONTRACTOR TO PROVIDE "JB C+D" WITH SAMPLES FOR THEIR APPROVAL. 4. &.C. WILL PREP FLOOR PRIOR TO ANY INSTALLATION OF FLOOR FINISHES, SLAB TO BE LEVELED AND CRACKS TO BE FILLED. 5. &.C. WILL USE bxb QUARRY TILE IN PREP FOOD AREA 4 KITCHEN 6. G.C. WILL USE ARDEX FLOORING SYSTEM # STRAIGHT QUARRY TILE BASE IN ALL PUBLIC AREA AS SHOWN IN PLAN RFFL.(f-,7Z7. C,f=ILINL. C7 N SYMBOL DESCRIPTION 41F1 NEW RECESSED INCANDESCENT FLOODLIGHT# ELHiT-116G BY "ELCO LISHTIN6" LAMP (1) 100 W PAR 50 - SOOOK OR EQUAL NEW RAIL W/ PENDANT LIGHT FIXTURE CHA-CHA BY TIELLA/TECH LI6HTIN +F2 TO BE FIELD SHORTENED. FIRE-POL€SHEO INCLUDES 12 V, COLOR: 6RAMMY APPLE GREEN/ CHILLI PEPPER/COBBALT BLUE/ PACIFIC. WHITE LAMP : 51-PIN - 5OW - USE SOON TRANSFORMER -ZTS NEN TRACK LIGHT SYSTEM N/ LOW VOLTAGE HALOOENE LIGHT BY "BRUCK" UNI-LIGHTS / MICRO MODEL ACCENT LIGHT W/ STEM EXTENSION LAMP MAX : SON OR EQUAL ©4 NEW 2'x2' RECESSED FLUORESCENT LIGHT FIXTURE BY LITHONIA BY LITHONIA KITH 2 LAMPS 40 N T12 - SHATTER PROOF OR EQUAL NEW 7x4' SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE 5 LAMPS 40 N T12 - SHATTER PROOF OR EQUAL NEN PARTITION -CONSTRUCT FROM FLOOR TO 6" ABOVE SUSPENDED 01-6.- 2 1/2" X 20 6A. STEEL STUDS /^ti B 24" O.C. N/ ONE LAYER OF 5/6" GYP. BD, ON EACH��.� SIDE, R-6 BATT INSULATION BETWEEN STUDS AS REQUIRED NEW 1-1161-f-LINE Ll6HT BY BRUCK WITH "STELLA" HEADS # 150250 MATTE HALLS TO BE TAPED FILLED B SANDED SMOOTH, READY FOR FINISH. F6 CHROME FINISH N/ MRI6 LAMP SON NEW LON PARTITION -CONSTRUCT FROM FLOOR TO + 42" A.F.F. OR 4e ". -� NEN NALL SCONCE AVALON WITH ORB BY TECH LI6HTIN6 12V, 2 1/2" X 20 6A. STEEL STUDS a 24" O.C. W/ ONE LAYER OF COLOR COBALT AND AMBER WITH SATIN NICKEL 5/6" GYP. BD. ON EACH SIDE, PROVIDE ADEOUATE SUPPORT / LAMP MAX :5ON BY ADDING A STEEL TUBE TO BE ANCHORED TO FLOOR SLAB d WALLS TO BE FILLED 8 SANDED SMOOTH, READY FOR FINISH. F8 BLD6. STND. CL6. MTD. EXIT S€6N BY "LITHONIA" OR W. W/ BATTERY BACK UP POKER. Fa EN EMERGENCY LIGHT KITH BACK-UP BATTERY - QUANTUM # ELM2H BY "'LITHONIA" OR EQUAL �� I LL�N "j R< N�-+'j 7ES D NEN LIGHT DIMMER SWITCH WI MATCHING COVER PLATE NEN LIGHT SNITCH N/ MATCHING COVER PLATE 1. ALL CABINETS VERTICAL FINISH TO BE PLASTIC LAMINATE U.O.N.. 2. ALL CABINET INTERIORS TO BE WHITE MELAMINE RECESSED EXHAUST FAN Wl SWITCH 5. OPEN SHELF CABINETS TO BE PLASTIC, LAMINATE OR CLEAR &LASS U.O.N. CEILIN6 SERVICE ACCESS PANEL TO REMAIN. 4. OPEN SHELF CABINETS TO BE PLASTIC LAMINATE OR A.P. 5. ALL CABINETS HORIZONTAL WORK SURFACES TO RECEIVE STAINLESS STEEL OR STONE SLAB. U.O.N. S.C. TO PROVIDE EMRRENCY LIGHT AS PER FIRE PEP. REQUIREMENT. * INSTALL ALL NEW 11-16HT SWITCHES AND. THERMOSTATS* +42" A.F.F. U.O.N. 0921 gliz SYMBO MATERIAL MANUFACTURER STYLE NUMBER COLOR REMARKS RDARDEX I SD-T ESI6NER FLOOR T WEIGH CONCRETE ARDEX SD-T ARPfX SO-T TO MATCH OESPRIOR SAMPLER GG TO PROVIDE SX =P TO INSTALLATION USED IN PUBLIC AREA T 1 € i bxb QUARRY TILE AMERIGAN GLEAN 00"? UMBER USED IN PREP ROOM AND SERVICE AREA FAIRPI..AIhI AVE- WHITTIER, CA.90601 TE L.: � •• 369 ." ?01 R11 �' STRAIGHT OUARRY TILE AMERIGAN GLEAN QO7 UMBER USED IN PUBLIC AREAS IY521 6" COVED QUARRY TILE COVED BASE rMERICAN OLEAN 00*7 UMBER COVED BASE IN PREP ROOM AND SERVICE AREA 7EL./EL FC�7./DA7A L E6 ND 5YM50 DESCRIPTION NEW WALL MOUNTED FOURPLEX OUTLET 0 16" A.F.F. U.O.N. NEW WALL MOUNTED FOURPLEX OUTLET a 16" A.F.F. U.O.N. HALF OF THE FOURPLEX DEDICATED FOR COMPUTER - ORAN6E COLOR NEW WALL MOUNTED FOURPLEX SEPERATE CIRCUIT OUTLET SG ® 15 " A.F.F. U.O.N. NEW WALL MOUNTED DUPLEX OUTLET 0 16" A.F.F. U.O.N. NEW WALL MOUNTED DUPLEX OUTLET 5EPERATE CIRCUIT S.0 @ 16" A.F.F. U.D.N. NEW WALL MOUNTED TELEPHONE/DATALINE OUTLET, 3/4" CONDUIT e 16" A.F.F. U.O.N. �I NEW WALL MOUNTED DATA LINE OUTLET, 5/4" CONDUIT a l6" A.F.F. U.O.N. NEW WALL MOUNTED VOICE LINE OUTLET, 5/4" CONDUIT ® 16" A.F.F. U.O.N. 'NIP NEW WALL MTD. TELEPHONE OUTLET a 54" A.F.F. U.O.N. 4 NEW FAX OUTLET / SEPERATE TELE, LINE FAX NEW FLOOR MOUNTED TELEPHONE/DATALINE MONUMENT, FLOOR SLAB GORING 0 NEW FLOOR MOUNTED ELECTRICAL MONUMENT, DEDICATED HALF OF FOURPLEX - ORAN&E FOR COMPUTER USE. FLOOR SLAB GORIN& NEW WALL MOUNTED ELECTRICAL J-BOX + A,F.F. U.O.N. NEW WALL MOUNTED ELECTRICAL P16 TAIL a + A.F.F. U.O.N. # INSTALL ALL NEW RECEPTACLES 9 1611 A.F.F. U.O.N. NOTE: THE FASTENERS MUST BE INSTALLED THE UNDERSIDE OF THE STEEL DECK PAN(BETWEEN THE RIBS) CPA. VERTICAL WIRE 01) MPRESSION STRUT / POST GA. 3/4" BLACK IRON CHANNEL AT 17-0" O.C. W FASTENED TO ZIKTURE ABOVE, r OSS RUNNER #12 GA, SPLAY WIRE BRACING IN PLANE OF EACH RUNNER ATTACH TO STRUCTURE ABOVE. 4 WIRES a 0101,6, 12-0' O.G. LARR #221141 6 R O U NFLOOR Revisions PRELIM LANDLORD REVIEW 1/26/05 ISSUED FOR ENGINERIN& 1/26/05 ISSUED FOR HEALTH DEPARTMENT 2/14/05 ISSUED FOR LL APPROVAL 2/14/05 A ISSUED FOR PRICING 2/14/05 ISSUED FOR PLAN CHECK 2/14/05 Z s PLAN CHECK CORRECTIONS 5/50/05 HEALTH DEPARTMENT CORRECTIONS 5/50/05 A ISSUED FOR CONSTRUCTION ,4AIN RUNNER BRACING NOTES: 1. THE UNATTACHED PERIMETER SHALL HAVE 4NERTICAL POSTS MAY NOT ESE REQUIRED A MIN, OF 1/2" CLEARANCE AT ENDS IN SOME CITIES AND ALSO MAY NOT BE OF COMPONENTS. ENFORCED IN SOME SEISMIC, ZONES. 2. CONTINUOUS SPACER BAR TO BE LOCKED 5 BRACING WIRER TO BE ATTACHED AT A TO COMPONENTS ON THE UNATTCHED WALL. MAXIMUM OFES TO THE PLANE OF THE S. PERIMETER TERMINAL COMPONENT ENDS CEILING AND PARALLEL TO COMPONENTS Approved MUST SUPPORTED BY A 12 GA, WIRE 1NTERSECTIN6 AT THE BRACE LOCATION. pp ON ALLL WALLS. BRACE WIRES TO BE TAUT AND TIED BOTH Drawn J.B. Reviewed J.5. ENDS IN/ A MIN. THREE TIGHT WRAPS. Project No. VHgfile A.01 12 6A. HAN6ER Scale Issue Date 1/26/05 WIRE TERMINAL 6" MAX. ENDS OF ALL 81i MAX. NOTE 5 COMPONENTS SPACER BAR NOTE 2 --- MAIN RUNNER OR CROSS TEE ACOUSTICAL BD, �`- WALL ANGLE WALL ANGLE `- 1/6" POP RIVETS ON TWO OPPOSITE ADJ. TWO ADJ. WALLS WALLS, PROVIDE 1/2" SPACE (NO POP RIVETS) Sheet of A*01 r, M to O : m in 91 +/-22'-IO" III 111 -'" Il Il RA (E A l A FOOD PREPAREA -- { FOOD r ARE A\ F. EXISTING POOR --- , j EXISTING REC04 OM r ?f` O PUBLIC AREA ! t r- -- F.I. GASH 4. Ca" FOOD SERVICE AREA a 'a . c' PUBLIC AREA - I is ,- � -' \1\ ��•-,,, .- '-- 710- 71 1 — — _ _ _. _ ___. — ^ ._. — — __......_ _... __.. _.._ _._.. _ ...._ — _.._. — ___..._ — — - (D E® FINISH PLAN I SCALE: I/411_11-011 CONSTRUCTION NOTE5• PARTITION DIMENSIONED TO FINISH PAGE USE TYPE "X" GWB ON FIRE RATED PROVIDE SLOCKIN6 AS REQUIRED AT LOCATIONS U.O.N. PARTITIONS. INCLUDING BUT NOT LIMITED TO: GRAB BARS, 5fHELVING, USE WATER RESISTANT GWB ON PARTITIONS SCHEDULED OVERHEAD CABINETS, 916NAGE, TOILET ROOMS WHERE FURRED PARTITIONS EXCEED MAXIMUM HEIGHT, TO RECEIVE CERAMIC TILE (U.O.N). SEE FINISH SCHEDULE ACCESSORIES, ETC. BRACE TO ADJACENT STURCTURE, PER DETAIL. FOR LOCATIONS. FIRE SAFE PENETRATIONS AT RATED PARTITIONS PER FOR NON -RATED PARTITIONS, SEE DETAIL SHEET AB.I NO WOOD CONSTRUCTION ABOVE CEILING. WOOD USED IN APPLICABLE UL ASSEMBLY, SEE DETAIL SHEET AW. FOR EXTENT OF FRAMING AND FINISHES. CONSTRUCTION MUST BE FIRE RETARDENT. P69111ION PLAN NOTES: SEE SHEET A.01 FOR PARTITION PLAN LEGEND EXISTING 318" THK TEMPERED 51N6LE 6LAS5 ENTRY DOOR 3' WIDE AND 7' HT @' USE TYPE "X" GB ON FIRE RATED WALL PARTITION TYPICAL. USE "FRP" FIBERGLA55 REINFORCED POLYESTER PANELS # 5-100-6. WHITE FINISH BY "MARLITE" FLOOR TO CEILING IN THE PREP FOOD AREA. 4 G.C, TO INSATLL NEW 5/5 3 COMPARTMENT SINK AND TO DRAIN DIRECTLY TO SEWER WITH AN ADJACENT FLOOR DRAIN, AND THE SINK SHALL BE CONNECTED ON THE SEWER 51VE OF THE FLOOR DRAIN TRAP. NO OTHER DRAINAGE LINE 15 CONNECTED BETWEEN THE FLOOR DRAIN WAISTE CONNECTION AND THE FIXTURE DRAIN PER PLUMBIN6 CODE '70, NEW 50 GAL. ELECTRIC WATER HEATER TO HAVE A MIN. ENERGY IMPUT RATING OF 14 KW SEE ENGINEERING DRAWINGS PROVIDE S.S. CHEMICAL STORAGE SHELF W1TH MOP RACK, INCLUDING A JANOTARIAL SINK FAUCET WITH A THREADED OUTER LIP AND INSTALL NEW MOP SINK AS PER SCHEDULE . SEE ELEVATION PROVIDE A MIN. 2" CLEARANCE BETWEEN END WALLS AND THE PREP SINK OR AN INTEGRAL END RETURN, THE END RETURN MUST EXTEND UP THE WALL AT LEAST 8" AND BE SEALED TO THE WALL. ( ALL REFRIGERATORS TO BE SELF CONTAINED UNDERCOUNTER UNITS AND TO BE ON CASTERS. INSTALL GLA55 DISPLAY CASE SUPPLIED BY THE TENANT. 1® PROVIDE A GRANITE SLAB COUNTER TOP DISPLAY WITH A STRA16HT EDGE, DISPLAY WITH A GLASS SNEEZE GUARD WI BRUSHED ALUMINUM SUPPORTS AT FUDGE COUNTER. SEE ELEVATION AND DETAIL. e f I PROVIDE A LOW 916" THK TEMPERED GLASS PARTITION ABOVE LOW WALL OVER THE COUNTER, SEE ELEVATION # 12 PROVIDE BUILT-IN FRONT CUSTOMER SERVICE TRANSACTION COUNTER AT 54"HT WITH A GRANITE SLAB TOP FINISH AND PLASTIC LAMINATE BASE CABINET PER FINISH SCHEDULE AND ELEVATION. 13 PROVIDE A WALL HUNGER EMPLOYEE HAND SINK WITH HOT AND COLD WATER, INSTALL WALL MOUNTED 5IN6LE TOWEL AND 50AP DISPENSER, I4 PROVIDE A PREP SINK WITH HOT AND GOLD WATER, 15 PROVIDE A BUILT-IN CONDIMENT TABLE W1 A MINI SHELF AND LOWER WITH A STRAIGHT EDGE NATURAL STONE TOP AND 5ACK5PLA5H, INCLUDE TRASH RECEPTACLE I6 PROVIDE A BUILT-IN CABINET WITH A LOWER CABINET IN/ 5/5 WORK SURFACE TO INCLUDE A TRASH BIN AND UPPER OPEN ADJUSTABLE 5/5 5HELVE5. 5EE ELEVATION I"1 PROVIDE A BUILT-IN PLASTIC LAMINATE CABINET WITH A 5/5 TOP LOWER CABINET AND UPPER OPEN ADJUSTABLE SHELVES 18 PROVIDE A BUILT-IN PLASTIC LAMINATE UPPER CABINET WITH CLEAR ADJUSTABLE 3/45" THK 6LA55 SHELVES, SEE ELEVATION# 19 CANDY DRY CASE DISPLAY BY CLIENT. NEW 36" WIDE x la" DEEP x 6' HT WIRE CHROME OPEN SHELVES FOR STORAGE. G,G. TO ANCHOR TO WALL. 21 PROVIDE A 56" WIDE 5.5. DOUBLE SWING DOOR WITH A VISION LIGHT 22 64. TO PROVIDE A NEW BUILT-IN CLOSET WITH ADJUSTABLE SHELVES FOR STORAGE. 23 G.C. TO PROVIDE A BUILT-IN DISPLAY WITH OPEN 1/4" THK GLASS SHELVES, G.C. TO PROVIDE FLOOR SINK AS PER THE PLUMBING EN6INEERIN6 DE516N SHEET# P 25 6.0, TO REVIEW ALL SLAB CORE DRILLS WITH THE LANDLORD'5 ENGINEER PRIOR OF ANY WORK, SUBMIT A LAYOUT DRAWING 48 HOURS PRIOR TO START OF GORE DRILLING. IUS LE AXONOMETRIG: INSIDE CORNER 6" QUARRY COVED BASE 3/S" MIN. RADIUS .. 6," QUARRY TI 4. AXONOMETRIC: OUTSIDE CORNER EXISTING INALL5tPARTITION5 TO REMAIN NEW PARTITION -CONSTRUCT FROM FLOOR TO 6" ABOVE ZZZZ ZZZZ,, NEW LOW PARTITION -CONSTRUCT FROM FLOOR TO 48" ABOVE U.O.N. "SEE PARTITION LEC7END 5HEET# A.OI SEE DOOR LEGEND SHEET# A.OI USE GREEN BOARD WITH SEMI GLOSS ENAMEL BEHIND SINKS SEE FINISH LEGEND IN SHEET AO.I 1\11 /\1 J\ 11__� 1320 FAIRPLAIN AVE. WHITTIER, CA,90601 TEL.: 626- 369 3701 Revisions PRELIM LANDLORD REVIEW 1/25/05 A ISSUED FOR EwNERING 1/25/05 A ISSUED FOR HEALTH DEPARTMENT 2/14/05 A ISSUED FOR LL APPROVAL 2/14/05 A I55UED FOR PRIGiNca 2/14/05 ISSUED FOR PLAN CHECK 2/14/05 PLAN CHECK CORRECTIONS 5/50/05 HEALTH DEP. CORRECTIONS 5/30/05 A ISSUED FOR CONSTRUCTION OWNERSHIP AND USE OF DOCUMENTS All Drawtngs, Specifications and copies thereof furnished by �6 Concopt+Design ors and shall romain Its propsrty. 11hoy-are to be used oniy with respect to this Projeat and or* not to be used on ony other project, Submission or dtstrbutton to moot official rogulou" requirements or for other purposes in connection with the project Is not to be construed as pubitcatlon In derogation of rZ Concept+Design aormnon law copyright or other rossrvad rights. INTERIOR FINISH SCHEDULE FLOOR BASE WALLS CEILINGS Approved J.B. FOOD PREPARATION 6"x6" QUARRY TILE 6" QUARRY COVED BASE W/ 5/8" RADIUS 6' HT A.F.F. FRP WHITE FINISH BY MARLITE ALL EXPOSED AREA ABOVE TO BE 2'x4' SUSPENDED CEILING WITH W/ WASHABLE CEILING TILE Drawn J.B. Reviewed J.B. Project No. Dwg.File BE PAINTED LATEX GLEANABLE WHITE FIN15H SERVICE AREA 6"xb" QUARRY TILE 6" QUARRY COVED BASE W1 5/8" RADIUS " BACKSPLASH AND PAINT FIN15H ABOVE WALL NON A15WRBANT SMOOTH SEMI GLOSS HARDLID WITH SEMI GLOSS PAINT FINISH Scale = '© Issue Dote 1/25/05 LIGHT COLOR ( 70% L.R.V.) PARTITION PLAN PUBLIC AREA 12"x12" PORCELAIN TILE6" PORCELAIN TILE PAINT FINISH PER SCHEDULE DRYWALL AND OPEN CEILING W/ PAINT FINISHWISH FINISH PLAN 5TORAGE 6"xb" QUARRY TILE 6" QUARRY COVED BASE W/ 3/8" RADIUS 8' HT A.F.F. FRP WHITE FINISH BY MARLITE ALL EXPOSED AREA ABOVE TO BE WALL NON ABSORBANT SMOOTH SEMI &LOSS L16HT COLOR ('70% L.R.V) 2'x4' SUSPENDED CEILING WITH W/ WASHABLE CEILING TILE WHITE FINISH EXISTING 4' HT A.F.F. FRP WHITE FINISH BY MARLITE RE5TROOM 6"x6" QUARRY TILE 6" QUARRY COVED BASE W/ 5/8" RADIUS ALL EXPOSED AREA ABOVE TO BE WALL NON ABSORBANT SMOOTH SEMI 61_05 DRYWALL CEILING WITH SEMI -GLOSS PAINT FINISH .. A1 LI&HT COLOR ('70% L.RR.V) Sheet of L<ISH71NC-7 4 ELEC,7RICAL NOTES 1. REFER TO ENGINEERING DRAWINGS FOR ALL CIRCUITING AND POWER REQUIREMENTS, THE ARCHITECTURAL DRAWINGS ARE FOR LOCATIONS AND DIMENSIONS. 2. G,G. TO FURNISH AND INSTALL ALL LIGHTING, HVAC AND RELATED MECHANICAL WORK IN STRICT COMPLIANCE WITH LOCAL CODES. 1 NIGHT LIGHTS, EXIT LIGHTS AND ALARMS SHALL BE PROVIDED BY G.C, AS REQUIRED BY APPLICABLE GORES. 4. ALL LIGHTING 15 TO BE INSTALLED IN CONFORMANCE WITH PERTINENT ELECTRICAL CODES. 5. ALL RECESSED FIXTURES SHALL BE SET FLUSH WITH ACOUSTIC TILE CEILING; AS RECOMMENDED BY MANUFACTURERS. 6. ALL LIGHT FIXTURES MAY BE SUBSTITUTED BY FIXTURE OF EQUAL OUALITY WITH APPROVAL BY JB CONCEPT + DESIGN. 7. WHERE MORE THAN ONE SWITCH ARE LOCATED TOGETHER THEY SHALL HAVE A COMMON FACIE PLATE. S. G.C. SHALL RECIRCUIT AND REWIRE EXISTING PANELBOARD (5) AS REQUIRED IN ELECTRIC CLOSET TO ACCOMMODATE JS CONCEPT + DESIGN ELECTRIC POWER AND LIGHTING DESIGN 9, PANELBOARD CIRCUIT BREAKERS SHALL BE NEATLY TAGGED AND NUMBERED BY G,G. TO CORRESPOND WITH CIRCUITING OUTLINED ON ENGINEERING DRAWIN65. 10, G.G. SHALL PROVIDE ALL NEW PANEL BOARDS A5 REQUIRED IN ADDITION TO ANY REQUIRED REWIRING OF EXISTING, SEE ENGINEERING DRAWINGS. 11. G.G. SHALL PERFORM ALL ELECTRICAL WORK IN ACCORDANCE WITH ANY AND ALL GOVERNING LOCAL CODES, THE NATIONAL ELECTRIC CODE AND BUILDING RULES AND REGULATIONS. t2. G.G. SHALL PROVIDE AND INSTALL ALL ELECTRIC CONTROL WIRING TO PROVIDE A COMPLETE SUPPLEMENTARY AG SYSTEM. SEE ENGINEERING DRAWINGS, 13. G.G. TO PROVIDE AND INSTALL COVER PLATES FOR ALL WALL MOUNTED ELECTRICAL AND COMMUNICATIONS OUTLETS. 14. &C. SHALL PROVIDE 1I5V SEPERATE CIRCUIT AND SURGE PROTECTOR IF REQUIRED. ! 15, ALL WALL MOUNTED DATA AND VOICE RECEPTACLES TO HAVE 3/4" CONDUIT STUB UP AND TERMINATED 6" ABOVE HUNG CEILING. 16. G.G. SHALL PROVIDE AND INSTALL ALL REQUIRED GLASS T" CONTROL WIRING. ALARMS AND SPEAKERS REQUIRED BY CODE AND BUILDING RULES AND REGULATIONS ALL GLASS T" WORK SHALL BE COORDINATED WITH LANDLORD AS REQUIRED. (SEE ENGINEERING PLAN). ALL CLASS "E" WORK SHALL COMPLY WITH LOCAL DEPARTMENT OF BUILDINGS AND OR ANY SUCCESSOR LAW OF LIKE IMPORT AND BUILDING RULES AND REGULATIONS. 17. ALL CORE AND OR FLOOR TRENCHING FOR TELEPHONE / ELECTRICAL CONDUITING SHALL BE PERFORMED ON OVERTIME AS REQUIRED AND COORDINATED WITH LANDLORD FOR APPROVAL, 18, FOR ALL ELECTRICAL CONDUITS THAT MUST BE RUN IN CEILING OF FLOOR BELOW MUST BE IN RIGID CONDUIT OR EMT WITH NO JUNCTION BOXES WITHIN THIS FLOOR. 19, ALL LOW TENSION CABLING RUN THROUGH POKE-THRU ASSEMBLIES TO FLOOR BELOW SHALL BE IN EMT CONDUIT (SEPERATE CONDUITS FOR TELEPHONE AND COMPUTER CABLES). 20. ALL CONDUITS SHALL BE 4" O.G. MINIMUM AND SHALL BE PROPERLY HUNG FROM STRUCTURE ABOVE WITH KINDORF CHANNELS APPROPRIATELY SIZED HANGER R005 AS PER NATIONAL ELECTRIC CODE AND LOCAL DEPARTMENT OF BUILVIN65 HAVING JURISDICTION OVER THIS PROJECT'S ELECTRICAL COVES. ALL LOW TENSION CABLE CONDUITS SHALL BE SUPPLIED WITH POINT TO POINT DRAG LINES TAGGED AT EACH END. THERE SHALL BE NO JUNCTION OR PULL BOXES IN THE FLOOR BELOW. 21, ALL POKE -THROUGH ASSEMBLIES SHALL BE FIRE RATED TYPE AS MANUFACTURED BY O.Z. GEDNEY OR APPROVED EQUAL AND SHALL BE FIRE STOPPED TO MAINTAIN FIRE RATING AS PER LOCAL DEPARTMENT OF BUILDINGS HAVING JURISDICTION OVER THIS PROJECT, 22. THE G.G.'S HVAG AND ELECTRICAL SUBS SHALL SUBMIT SHOP DRAWINGS AND SPECIFICATIONS COVERING ALL ITEMS FOR THE DESIGN INTENT APPROVAL PRIOR TO CONSTRUCTION. 23, ALL DUPLEX RECEPTACLES AND OTHER OUTLETS IN WALLS WITH SPECIAL APPLIED FINISHES {WOOD PANELING, CORK, ETC.) SHALL HAVE THE FACE OF THE ROUGHING BOX SET FLUSH WITH FACE OF APPLIED FINISH. SEE ELEVATIONS DRAWINGS. 24. WHERE OUTLETS, JUNCTION BOXES ARE LOCATED BEHIND CABINETS, THE CONTRACTOR SHALL PROVIDE FOR ACCESS TO THESE BOXES IF DESIGN APPEARANCE, STRUCTURE OR FUNCTION OF CABINET 15 NOT IMPAIRED. WHEREVER A QUESTIONABLE CONDITION ARISES JB SHALL BE NOTIFIED PRIOR TO COMMENCEMENT OF WORK. 25, THE CONTRACTOR SHALL COORDINATE ANY ELECTRICAL WORK OR LIGHTING INSTALLATION INTO CABINET WORK IF AND AS REOUIREV. 26, O.C. TO PROVIDE PULL STRINGS IN ALL EMPTY CONDUIT. 27. ALL EQUIPMENT INSTALLED SHALL BE LISTED AND / OR LABELED BY AN APPROVED AGENCY 29, GROUND MAY BE USE THE CONDUITS AND ITS CONNECTORS, IF U.L. LISTED AS GROUNDING CONDUCTOR 29. ALL CONDUIT SHALL BE EMT OR STEEL FLEX. ALL WIRING SHALL BE THHN U.O.N T L• .1ELaE�T./DATA LE&E'I O SYMBOL DESCRIPTION NEW WALL MOUNTED FOURPLEX OUTLET • la" A.F.F. U.O.N. NEW WALL MOUNTED FOURPLEX OUTLET i IS" A.F.F. U.O.N. HALF OF THE FOURPLEX DEDICATED FOR COMPUTER - ORANGE COLOR NEW WALL MOUNTED FOURPLEX SEPERATE CIRCUIT OUTLET SC • 18" A,F.F. U.O.N. NEW WALL MOUNTED DUPLEX OUTLET • I8" A.F.F. U.O.N. NEW WALL MOUNTED DUPLEX OUTLET SEPERATE CIRCUIT S.0 0 18" A.F.F. U.ox ,.i NEW WALL MOUNTED TELEPHONE/DATALINE OUTLET, 5/4" CONDUIT • 18'" A.F.F. U.O,N. Q NEW WALL MOUNTED DATA LINE OUTLET, 5/4" CONDUIT a IS" A.F.F. U.O.N. NEW WALL MOUNTED VOICE LINE OUTLET, 5/4" CONDUIT ! IS}} A.F.F, U.O.N. NEW WALL MTV. TELEPHONE OUTLET 0 54" A.F.F. U.O.N. WP A NEW FAX OUTLET / SEPERATE TELE. LINE FAX { NEW FLOOR MOUNTED TELEPHONE/DATALINE MONUMENT, FLOOR SLAB GORING 0 NEW FLOOR MOUNTED ELECTRICAL MONUMENT, DEDICATED HALF OF FOURPLEX - ORANGE FOR COMPUTER USE. FLOOR SLAB CORING NEW WALL MOUNTED ELECTRICAL J-BOX ! + A.F.F. U.O.N. -a NEW WALL MOUNTED ELECTRICAL PIG TAIL i + A.F.F. U.Q.N. TV NEW WALL MOUNTED TV ANTHENA i + A.F.F, U.Q.N. * INSTALL ALL NEW RECEPTACLES @ 18" A.F.F. U.O.N. 1320 F'AIRPI_AIN AVE. WHITTIER, CA.90601 TEL.: 626- 369 3701 '[EQUIPMENT WASTE LINE —mm m m i S I ©1 r LliiY4iilii� • 1 ii#� � � ®TURBO t D i ! OEM* ' 1 TURBO ! N ! / ®��A� ®� ����� i �Y��. r r i i i.. 1 1 A [ [ ! 1 S/S SINK THREE COMPARTMENT • ter" ""�ii' it 91 ' 11 BY CAGO : DOUBLE !SPOUT [ rr ! �+ [ 1 [ !!r ADJACENT p� r STAINLESS STEEL SHELVING :;CONFIRM WITH OWNER FOR DEPTHS FLOOR SINK FLOOR SINK �=[ICE MAKER- LARGE 400LBS MIN, • r ^ •ENKO PERSONAL w LOCKER ♦ 1 1 [ ! 1 FOOD-SERV-- ICE APPLICATIONS ^ CHROME SERVICEFOOD APPLICATIONS J [ ♦ 1 74,N RE �Mj 1125fdo _0112TSWIM11,70mal _ If '�- ®� • �� ^ - 1 _ l ! 1. 1. 1 4 l L [ =` i l C..,..., �mi ICE BLENDING MACHINE :ISLAND OASIS SB-3X 1 ! r r r [ .[ r i 1 ^ • �WTURBO [ *. J * SELF CONTAINED i ; i li �� [ �,SELF CONTAINED >t� i [ A ■_ [ '•Ri7,� mm Key 7i 4 r .. A l r •_ [ A i 1♦ i [ l i t[ l [ l l �, 1 4, 1 4 ► 1 M y lw._LANDLORD r I�® ! - ! - rY * • ' -! .r - ' - • 1®'�w��TU r . i + i : i i : _ 1 r - iCONTAINED[ ��1 - CONTAINED ISSUED FOR •• ISSUED FOR HEALTH DEPARTMENT 2/1-4/05 r! r [ r • 1 i i i �.� ��� r l r r ! • APPROVAL2/14/05 ��I r ` DISPENSER r ������� r• r r r r[ FLOOR SINK��■� !DRAIN ! FLOOR SINK ISSUED FOR r r FLOW DRAIN COFFEE BREWER PLAN CHECK i�®)FUDGE KETTLE [01111-i������ir�LIC �� '�'� CORR- s r r ���'�GSW S/S HAND SINK W/ FAUCET 16"Wx15"Dx15"H III I R5 t ra 61 IN z cal ISSUED FOR CONSTRUCTION EMPLOYEE HAND SINK A ICED DRINK MACHINE DIS PLAY CASE 48!-HEALTH MP. CORRECTIONS 5/50/05MUM ALTERNATIVE AIR # AACCA-R/D SIZE: 48"Wx 0k*ZftH)P AtO USE OF PO LA-PAVONI" BAR V3 SIZE: 36"Wx 21"Dx 21"H ory and shall remain Its proportg, Thog are to be used on1V mith respect to distribWom to meet offle'lal rowl=oSviromomts or for other pwposes In �MJFUPRESSO GRINDER ���@�����MGRIND MASTER # 890 GRINDER SIZE. 27"x7"x15" ewmection v4ith " projer-t Is not to corstrvoia as ptblizatlon Im derogation �M[E)(PRESSO KNOCKOUT BOX ��I��������� � Of - other-- -rights. COFFEE GRINDERS Approved PLEAGLASS COFFEE BINS SUPPLIED BY 0)i AINER I FAMON I WNTM MI NM r Ar �_�_�_�_�__ r r. r r s. , , ..� �� ► .. :. — .. _ ,. ,r ®�I TRASH r r l r i ��®���� r .r r BY OWNER� ■�� �r Froje6t No. �" r FUDGE DISPLAY axi Bey Ii i�� r r r r r r 5CAL E: 114't I_�tt REFLECTED CEILING PLAN NOTES: SEE SHEET A.01 FOR REFLECTED CEILING LEGEND 1. FOR GENERAL NOTES AND LEGENDS, SEE SHEETS AO.I 2 ALL FIXTURES ARE NEW, U.O.N. E INDICATED EXISTING AND R INDICATES RELOCATED FIXTURES. G.G. TO VERIFY LIGHT FIXTURE OUANTITIE5 AND REUSABILITIES, 3. NEW SUPPLY AND RETURN GRILLE LOCATIONS PER ENGINEERS DRAWINGS 4. NEW SPRINKLER AND FIRE SAFETY DEVICE LOCATIONS PER CODE REQUIREMENT. 5. NEW EMERGENCY LIGHT AND EXIT 51GN LOCATIONS PER CODE REQUIREMENT. ALL FIXTURES AND SPRINKLER HEADS TO BE LOCATED AT CENTERLINE OF TILE, U.O.N NEW FIXTURES TO MATCH 5UILDING STANDARD, U.O.N. G.G. TO VERIFY ALL EXISTING SPRINKLER HEADS ARE TO BE WITH CONGEALED HEAD AND FOR PROPER FUNCTION. G.C. TO VERIFY EXISTING SPEAKER/STROBE LIGHT LOCATIONS AND SPECIFICATIONS AND TO COMPLY WITH CODE REQUIREMENTS. ALL NEW WALL SWITCHES 10. CONTRACTOR SHALL PROVIDE AND INSTALL EXIT LIGHTS AS REQUIRED PER CODE. II. NEW LIGHT FIXTURES TO BE INSTALLED AS INDICATED. SEE PLAN i2 FOR TYPICAL LIGHT SWITCH, THERMOSTAT AND STROBE MOUNTING HEIGHTS PER ADA REDUIREMENTS I5. VERIFY ALL RECESS DEPTHS OF FIXTURES AGAINST A.G. DUCTS, PIPES, BEAMS, ETC, BEFORE ORDERING FIXTURES AND SUBMIT GUT SHEET OF ALL FIXTURES TO ARCHITECT AND ENGINEER FOR APPROVAL. I4. ALL NEW SWITCH PLATES SHALL BE INSTALLED AFTER FINAL PAINTING 15 COMPLETED, I5. ALL LENSES, REFLECTORS, LAMPS, PLATES, ETC., ARE TO BE THOROUGHLY CLEANED AT THE COMPLETION OF THE WORK. USE NEW 2X4 VINLY FACED FIBERGLASS- SQUARE LAY -IN - OWN piWAA -Vt. WASHABLE 4 SGRUSBABLE WITH 15/16" EXPOSED TEE GRID BY ARMSTRONG .OR E0. REFLCTD, CEILING LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION NEW AIR SUPPLY +F1 NEW RECESSED INCANDESCENT FLOODLIGHT # ELH 7-116C BY "ELCO LIGHTING" LAMP (1) 100 W PAR 50 - SOOOK OR EQUAL NEW AIR RETURN NEW RAIL IN/ PENDANT LIGHT FIXTURE CHA-CHA BY TIELLA/TECH LIGHTING TO BE FIELD SHORTENED. FIRE -POLISHED INCLUDES 12 V, COLOR. F2 GRAMMY APPLE GREEN/ CHILLI PEPPER/0055ALT BLUE/ PACIFIC. WHITE NEW LIGHT DIMMER SWITCH W/ MATCHING COVER PLATE LAMP: BI-PIN - 50W - USE 500W TRANSFORMER NEW LIGHT SWITCH IN/ MATCHING COVER PLATE NEW TRACK LIGHT SYSTEM W/ LOW VOLTAGE HALOGENS LIGHT BY RECESSED EXHAUST FAN W/ SWITCH "BRUCIC" UM -LIGHTS / MICRO MODEL ACCENT LIGHT W/ STEM EXTENSIONS LAMP MAX :50W OR EQUAL NEW 2`x2' RECESSED FLUORESCENT LIGHT FIXTURE BY LITHONIA ®F4 NEW CEILING SERVICE ACCESS PANEL. BY LITHONIA W1TH 2 LAMPS 40 W T12 - SHATTER PROOF OR EQUAL A.F. F5 NEW 2`x4' SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE G.G. TO PROVIDE EMRGENGY LIGHT AS PER FIRE DEP. REQUIREMENT. 5 LAMPS 40 W Tit - SHATTER PROOF OR EQUAL * INSTALL ALL NEW LIGHT SWITCHES AND, NEW HIGH -LINE LIGHT BY BRUCK WITH "STELLA" HEADS # 150250 MATTE THERMOSTATS 0 +42" A.F.F. U.O.N. CHROME FINISH W/ MRi6 LAMP 50W F6 NEW WALL SCONCE AVALON WITH ORB BY TECH LIGHTING 12V, COLOR COBALT AND AMBER WITH SATIN NICKEL F7 LAMP MAX ;50W BLDG. 5TND. CI-G. MTD. EXIT SIGN BY "LITHONIA" OR EO. F8 W/ BATTERY BACK UP POWER. NEW EMERGENCY LIGHT WITH BACK-UP BATTERY - QUANTUM # ELM2H BY "LITHONIA" OR EQUAL. F9 lk DEMOLITION NOTES: SEE SHEET A.OI FOR DEMOLITION PLAN LEGEND 0t l t G.G. TO KEEP EXISTING H.V.A.C. UNITS TO BE CHECKED 4 SERVICED FOR PROPER �� JJ USE- NEED AN AIR BALANCE REPORT TO BE SUBMITTED TO THE OWNER G.G. TO KEEP HANDICAP EXISTING RESTROOM WALL AS 5HOWN, ALL PLUMBING FIXTURES TO REMAIN *�✓ EXISTING STOREFRONT GLASS AND DOOR TO REMAIN. i� G.G. TO PROTECT EXISTING STOREFRONT, AND EXI5TIN6 6LA55 PARTITION TO REMAIN. G.C. TO DEMO EXI5TIN6 SUSPENDED CEILING SYSTEM AND LIGHT FIXTURES TO Be REMOVED EXI5TIN6 ELECTRICAL PANEL TO REMAIN. 1320 FAIRPLAIN AVE. WHITTI.ER, CA.90601 V TEL.. 26- 369 3701 N T w Q a U) I z /W V 0 W x u r� 1rf W T 6f�6UN-1�)" FLOOR Revisions PRELIM LANVLORQ REVIEW i2 /05 ISSUED FOR ENGINERING 1/25/05 ISSUED FOR HEALTH DEPARTMENT 2/14/05 A i55UED FOR LL APPROVAL 2/14/05 A ISSUED FOR PRIDING 2/14/05 A ISSUED FOR PLAN CHECK 2II4I05 A PLAN CHECK CORRECTIONS; 5/50/05 A HEALTH PEP. CORRECTIONS. 5/50/05 ISSUED FOR CONSTRUCTION A A� omeRSHIP AND USS of DOCUMENTS All Drawings, Spowmattorns and copies thereof furnished by .10 Concept+Design are and shall remain Its property. they are to be used only with respect to this Project and are net to be vied an any other project. Submission or dtstrbvtlon to meet Offclol regulatory regvtrements or For other pvrposes In cormectton with the project is not to be construed as publication In dotogotton Of .0 GanceptrDestgn common Iaw copyright or other reserved rights. Approved .1.8. Drawn .I.B. Reviewed .l.B. Project No. Dwg.Flle Scale issue Date 1/25/05 �E I L 1 NC7 PLAN • •mum-NOM .WwwWw''i ffilliil ---,' SGA�L�: 114tt� � t_�tt Alp - Sheet of A3 4 c1 V .i.T-. WALL ELEVATION A EXISTING H(� 'TOILET ROOM LEGEND HC. APPROVED TANK TYPE WATER CLOSET, WITH 1'7" HIGH OPEN FACE SEAT. HANDLE MOUNTED ON WIDE SIDE OF TOILET WITH THE MAXIMUM OF 3 LES. OPERATING PRESSURE 2 LAVATORY, WALL HUNG, MOUNTED AT MAX. + 54" TO TOP OF SINK AND PROVIDING 211" CLEAR TO BOTTOM OF APRON AND FOR A MIN. DEPTH OF b" PROVIDE BRASS WRIST HANDLES AT FAUCETS, 4" CENTERS, OPERASL WITH ONE HAND AND NOT REOUIRIN6 GRASPING, PINGHIN6 OR TWISTING. PROVIDE HOT/COLD MIXING VALVE AS REQUIRED WRAP AND INSULATE EXPOSED HOT WATER AND DRAIN PIPING. NO SHARP OR ABRASIVE EDGES ALLOWED BELOW SINK. D5 (NOT USED) 4 1 1/4" X 56" LONG GRAB BAR, 1 1/2 CLEAR FROM WALL. ASI SERIES 5100, TYPE-01, MOUNTED AT +55".OR EQ. 5 1 1/4" X 45" LONG GRA5 BAR, 1 1/2 CLEAR FROM WALL. ASI SERIES 5100, TYPE-01, MOUNTED AT +33". OR EQ. 6 SIN6LE ROLL TOILET TISSUE DISPENSER, SURFACE MOUNTED AT + 24". ASI #'7305-2 OR EQ. Y.I.F. WALL ELEVATION B SCALE: N.T.S. "TI46 TOILET ROOM PLAN -� PAPER TOWEL DISPENSER, WALL MOUNTED AT + 40" TO TOWEL OPENING. A61 #0210 OR E0. 8 MIRROR, 1/4" POLISHED PLATE BLA55 WITH 1/2" X 1/2" X 1/2" S.S. CHANNEL FRAME. ASI #0620. BOTTOM OF MIRROR AT TOP OF COUNTER 15AGK5PLASH, MAX. + 40". IV WIDE X 50" HI6R OR EO. q LIQUID SOAP DISPENSER, WALL MOUNTED AT + 40" TO TOWEL OPENING. ASI #0545 OR EO. i0 SEAT PROTECTOR SHEET DISPENSER, SURFACE MOUNTED AT + 40" TO OPENING. A51 #0477-5M. OR EQ. 11 ADA AND STATE OF CALIFORNIA APPROVED H.C. SYMBOL TO BE MOUNTED AT CENTER OF DOOR AT 60". 12 ADA AND STATE OF CALIFORNIA APPROVED H.G. GRADE 2. BRAILLE SIGNTO BE MOUNTED AT 60". OEXISTING HANDICAP RESTROOM PLAN /ELEVATIONS Y's-muc.-rupi BEAM .u, \ J SPAN BETISIEEN \ \ / w I -SEAMS W/ BOLT \ u / ....�� OPEN 15" DEEP AJJSTABLE GEILIN6 LINE I" THK wHIT5 MELAMINE NEW SHELVES ON HEAVY CEILING LINE C +lO'-0" A.F.F. >~RP DUTY WALL 5TANDAKDS @+41'-&" A.F.F. 6. TO PROVIDE � .GEQ L 1 BACKING SUPPORT .— CEILING LINE ,_.._ o+8'-O'" MIN.12" \ NEw \ 5PLA5HGUAR EXI5TIN6 = = z ICE RE5TROOM _ g AGHIN ? \ OPEN i \—CEILING, LINE @+10'-0" A.F.F. OFFICE HAND SINK-J G.G. TO INSTALL �6.0. TO INSTALL \—STAINLESS STEEL NEW PREP. SINK NEYIZOOMPARTMENT 51. „ _, , , ---I DOUBLE SWIN6 DOOR ELEVA71 ON / FLAN/ 5 C,71 CAN Ai F EF F00r7� AREA BASE TILE BASE I FREEZER / l fiilr flf REFRIGERATOR ) ---------------- M Ik 0 E tk f t { SiT0RA4E c, lif r-• . t t k r tk.4 ELEVA71 QN / FLAN/ S C,71 ON A7 fi~'REF FC OE. ARFA �y 1320 FAIRRI..AIN AVE. W H ITTI E R, CA..90601 TEL.. 626- 369 3701 f- Revisions LANpicgs2 Revir=-LN1 5 ISSUED FOR ENGINERIN6 !/28/OS / l ISSUED FOR HEALTH DEPARTMENT 2/14/05 ISSUED FOR LL APPROVAL 2/14/05 A ISSUED FOR PRICINB 2/14/05 ISSUED FOR PLAN CHECK 2/14/05 A PLAN CHECK CORRECTIONS 5/50/05 HEALTH DEPARTMENT CORRECTIONS 3/30/05 A ISSUED FOR CONSTRUCTION OWNERSHIP' AND USE OF 1204UMENTS All Drawings, 9pe41Fications and copies thereol' furnished by .0 Conce1000e61gr are and *halt remain its property. 'they are to be used only with respect to this project and are not to be used on any other project. 5ubmtsaton or, dtstributlon to meet official regulatory requirements or For other purposes in connectlon with the project Is not to be construed as pubitcatlon in dorogotion op ,lB concept+Design common tow copyright or other reserved rights. Approved Drawn J.B. Reviewed J.B. Project No. Dwg.F11e 5c01e Issue Date I/28/O5 LX 1 1 N Sheet of A. NEW PEN PER L16 . . TAINLESS TELL • "' I • r c� BEAMS LTS rSTRUCTURAL r • • LINE r 5OFil • ISH /� I� I L7 r 4 4 +�rrr rw�srsrr�ws.sl�ir f arsirirsrsw�wr�ws�s� Q t -ter # 1 ilv�l<< I �sC I�v�1 �� • ►��I I�v�l fi v1 f����l ICI I vl I�vkl ��I I .�.cl ��� �v�I C Ili to sib et! ■i a1 �� III��� Dl�a,,..,_...�................1....., L I � i► � i��w � rll�r�iiti�e.....�...��% If `�r/r "' i ' ��i.r.rrrr �Islr \--6.1 TILE BASE -**,�v DISPLAYS $Y TENANT \----rUV6F DISPLAY 6" TILE BASE CASHIER SERVICE GAUNTER ,. ORK t ! \ I i/PRQtr .. ,� y1l _'-____J-I+ilfl -__1I1i11 __J I I U ►I It li 1 111 �u>�4 -. ____ 0 -_�11 1111SOFT iiAPPUGINt7RINK51l 11 i1 Ld__J_iL_ U.iIpUI L... G____ L . --/ �1 -- -- J t r t PUBLIC AREA / BUILti IN < i ' tit �ii Di5PLAY / it tt DISPLAY- rt ------------------- 1 �? ✓ ry C t qt t L' p1,' ! 't __—__ i ads: 7t rJ fr tt DISPLAY ti �..- ___________________ V.1. PUBLIC AREA \� `�� �t A.' F00I�) 5ER\/I �E COUNTER ELEVATION 1 PLAN OPEN 15" DEEP AJUSTABLE I" THK STAINLESS STEEL SHELVE ON HEAVY CEILING LINE ! (l MENU BOA I I DUTY WALL STANDARDS @+10'-0" A.F.F. i ! ( BY OTHERS I l i I CEILIN6 LiNE 6.C. TO PROV i PE (} 11 I( I I 11 ADEQUATE WALL I' THK STAINLE$ STEEL SHELF I ( 1 i ( ( WALL+'-6" A.F.F. BACKING SUPPORT SCONE a STAINLE5 STEEL / MOVABLE TABLE 5/5 TOP l/V INTIN6 ART W 6-1 BACK =% BY TENANT BUILT-IN 5/5 COUNTER / / A-s 7000 8 iig 1 a o i.. N W KETT E OPEN SHELVE \ \ �,� ~..,, /�/—1 �J1, � ��,,, �- 8 TENAN UND R CQU�'F = — TRA -# 11DER CQU T R m REF 16ERAyT \ 1 FR I CGE Q OPEN SHELVE \ OPEN 22 6" OUARRY TILE -6" OVARRY COVED 51.1511 COVED BASE STAINLE55 STEEL TILE 5A5E DOUBLE SWING DOOR ! t i t it EXISTING t I MI Rt RESTROOM �� / f � 1 �LABLZ r RK TABL tf JJ 1\1 I ill liE 1 ✓rr lit tl E i I'll it il! ii� Itl wit t OVEN/PRQ �1 1 !1! 111 _ —1 U i� I I 1111 11 Ill 11i1 N! 1 _ -t'-----�- Wt----JIL 1 1L.1U L--- JLI-A------- A \ I ~- Er1 1320 FAIRPL.AIN AVE. WHITTIER, CA.9U6Qy TEL.. 626- 369 3701 Sc. 3/6".1'-0" 1 k I I Y C�`i;P�OUN1:;) FLOOR Revisions A PRELIM J.ANDLORD REV/JEW It29V05 ISSUED FOR ENGINERINry 1(28f05 A ISSUED FOR HEALTH DEPARTMENT 2/14/05 ISSUED FOR LL APPROVAL 2/14/05 n ISSUED FOR PRICING 2/14/05 A ISSUED FOR PLAN GHIwGK 2/14/05 A PLAN CHECK CORRECTIONS 3/3O/O5 HEALTH DEPARTMENT CORRECTIONS 3/30/05 L ISSUED FOR CONSTRUCTION A A A OwNERSHiP AND UM OF DOUJbiENTS All orawtngs, Specifications and copies thereof furnished by Jz concepttDesigt are and shalt remain its property. They ore to be used only with respect to I'll Project and are not to be used on " other project. Submtsslon or dtstrttn,Non to meet offtciai r4quIatary rec4utrements or for other purposes in correction with the project is not to be construed as publication in derogation of .z concept+oesign common taw copright or other reserved rights. A >e Approved J.B. Drawn J.B. Reviewed J,B. Project No. Dwg.Ftle Scale ISSUe Date 1/28/05 2 SAC,,,<V�ALL ELF\/A7I ON l PLAN A7 FOOD? SERV IC r- AREA 5� Sheet of A. ° v a ° °4 4. 2 1/2" MTL STUDS 20 GA ANCHORD TO UNI-STRAUT / UNI- T SPAN 5F-1 r% STRIXMRAL 1-5EAMS Y41 BOLTS EXISTING STRUCTLRE GEILiNG LINE BRAOiN AS REQUIRED C�+IZ`-o" A.F.F. __ _ ", PL. _`\��N(�.•--� / NEW LIGHT PER LIGHT GEILINJ LINE @+q "-6'" A.F.F IIt 110111111 EILING LINE +10'-0" A.F.F. MICROWAVE / STAi E 5 EEL -' co 5/5 TOP W/ !/ MOV BLI 7 ABLE ® 6" BACK SPLASH o OPEN SHELVE S OPEN SHELVE 171 6" QUARRY TILE 6" TILE 5A5E 6" TILE 5A5E COVED 5A5E CEILING LINE n+10'-0" A.F.F. C�ERATo IF L.V/A71ON / PLAN ° 5 5/6" MTL STUDS 20 GA ANGHORD TO UNI-STRAUT GEILI 0+11-6 \ rr G LINE OE G LiNE " A.F,F. F.F. \ NEK4 T11/ .%11$� \ u � F 11' i �1 If �1 i F l Lc K� { iL-__1 i t I 1 Il EEZi2 it 02 F,�TITL, \ TF��F ` 1 rr 1 1 i T-Tn 11 i fii I 1 r 1 F2 r r� % r it ,\ rr r ( rr 1 {1 1 .' 0 1 I r1 rr r 1r it F2i i r'r `tirF2X X�Ck � i , i 'rr rrD i SPLAY ` 11 N 4� -- A.5 FLEVATION PLAN c.vt.vriN 1 1 ! t r 2 Ft6 .0 ! / 1 1 ! 1 4, E�NDIME o01 a o� 1 1 / 1 ! ! t 1 1 ! t ( / ! ! EL EVA71©N I PLAN to I I1-= C3R�ir 6" TILE 5A5E iolgWirI�I« STAiNLE55 5TEEL NEW DOOR NO AS GE ING LINE �+ 2 A.F.F. V iN G ILING LINE . F. tti WALL / SCONE +/i f-ofl KKJJ i/ A ICE �MACHINEr—_—Mza- EX15TIN& GRANITE 5 D. WINDOWS COUNTER TO ff--i- I BY E i 1( v ( UNDER TRA5 © © I COUNTER i t t / REFR. 7— 9 k L fill OR "I L Of I ji F 5�; Sc,: 5/6": i'-0" F.tt �• 1 Tom,_ i SC" 3/b". 1'-0" CONDIMENTS \ L--CASHIER TTA5LE 6" TILE 5A5E r F2 - / � t / t 1 �- f kF JF�201 ' / �k t! !! i ii� 15PL� ,i I► F2 i !!1 i M06 / ! L t 1 4 .. I 1 i I r !1 ! 4- IF 1! <! PUBL I G AREA r OR A-, qu I IF 1 1 I t n ! (( ! f t 41 I I 1 F2 r !!�- !1tI 13 G ' l�)l T5 TABLE /' �' ,' /; <„Atllt ` I / r ===a i t. 2) ELEVATION 1 PLAN mm� kK TABLE � t i AINLES 6 " QUARRY TI LE COVED BASE •�J t 7 'r U 1320 FAIRPLAIN AVE. WHITTIE01 CA.90601 TEL.: 626- 369 3701 Revisions A PRELIM LANDLORD REV1><104 IL O5 LISSUEI7 FOR EN&NERIN6 1/26/05 1 1 !!i ! A ISSUED FOR HEALTH DEPARTMENT 2/14/05 A 155UE7 FOR LL APPROVAL 2/14/0! A 155UED FOR PRIGIN6 2/14/05 ! y!! A i55UED FOR PLAN CHECK 2/14/0! PLAN CHECK CORRECTIONS 3/50/0 HEALTH DEPARTMENT CORRECTIONS 3/30/0 1_1�1+w ISSUED FOR CONSTRUCTION 1 l A OW Z"14iP AND USE OF DOCUMENTS All DraMtngs, 5peeiftcations and coptoo thoraoP Purnishad by .Z Concept are and shall remain its propart y, They arm to be vsod only with raopeci this Projact and are not to be vied on any other project. 5vbmission or dtatrUtton to meet aPficiat rovatory ro vtromonts or for other, purpos connection with the projeot is not to be construed as pvbNcation to dery OP .s concept+peatgn common law copyright or other reserved rights. Approved J.E. Drawn J.B. Reviewed J.B. Project No. Dma.File Scale ISSUO Date 1/28/05 LVT 1 N Sheet Of A. 6 a c u Q 4 o . 4-0 4 4 a DO NOT ATTACH WALLS/ BRACING TO DECK - ATTACH TO TOP OF CMOF ca © 0 0 o © Cp 0 OF L.L'5 STRUCTURE UNI-STRAUT SPAN BETWEEN �_Ss —A / STRUCTURAL 1-5EAM5 W/ BOLTS 5 5/6" x 20GA.. STUDS (FLAT) 45 DEGREE DIAL, CORNER BRACE WITH (2) # 8 S.M. SCRs REQUIRED ONLY INHERE WALL EXCEED 10' IN LENGTH - OTHERN415E NOT REQUIRED) ATTACH TOP TRACK TO GRID W! 2-#6 5-12 ._ --- 5CREW5 2'-0" O.C. Ei SCHEDULED CEILING 5/8" TYPE 'X' GYP. BD, ON EA, 51DE OF 3-5/8" X 25 GA. MTL. STUDS @ 24" 0.0, STUD CRIMPED AT HEAD TO RECEVVI; TOP TRACK. SCHEDULED FLOORING SCHEDULED BASE INTERIOR PARTITION METAL RUNNER FASTEN TO SLAB W/ POWER ACTIVATED FASTENER I/$" /s X 3!4" MIN. PENETRATE 2'-O" O.C. CONTINUOUS ACOUSTICAL SEALANT BOTH SIDES (FINISH (FINISH FLUSH WITH PARTITION) SEALANT UL A55EM SCALE 4 DE_7-M151N5 ^ALL PPLKTIT1UN N.T.S. 1CONNECTION AT GONGRETE DFG#C + UNDER E OF STRUCTURAL SLAB G TINUOUS ETAL STUD TOP RUNNER GYP. BD, TYPE "X" ON BOTH 51DE TO 6" ABOVE GEILIN6 C14 SCHEDULED CEILING SEE REFLECTED GEILIN6 PLAN FOR SPECIFICATIONS $ HE16HT5 FIRE RETARDANT TREATED WOOD BLOCKIN6 BEYOND AS REQUIRED 1 1/2" METAL STUDS 25 6A 50HEOULED BASE METAL FLOOR RUNNERS SEALANT ARTITION TYPE { VNAtLL @ POr,<ET 1 O)OR) �SGALE 7 I N.T.S. 1 /2", 2 1 /2" 1 1 TYPICAL POCXET C)OOR j STEEL PLATE STOP STUD 5HORT FOR VERTICAL EXPANSION 1/2" MEN FLOOR TO' UNDERSIDE OF STRUCTURE DIMENSION 15 GREATER THAN 12'-0" SEALANT PER UL ASSEMBLY V.I.F. EXISTING CONCRETE SLAB CONTINUOUS METAL STUD TOP RUNNER SCHEDULED RATED PARTITION SCHEDULED GEILIN6 SEE REFLECTED CEILING PLAN FOR 5PECIFICATION5 d HEI6HT5 SCALE N.T.S. 1 I/2" METAL STUD RUNNER TIE TO SLAB ABOVE METAL STUDS / POCKET DOC HARDWARE RIES NO. 1150 CONTINUOS FIRE RETARDANT TREAT WOOD BLOCKING GUT REFER TO R,C,P. CONTINUOUS 6,13. METAL CASING TYP. 1/4" REVEAL SCHEDULED METAL FRAME 1 5/4" 50LIP CORE WOOD POCKET DOOR STAINED CONCRETE FLOOR TOP OF SLAB 2x2 x3lib" THK STEEL TUBE BRACE AT PARTITION END. HEIGHT AS REQUIRED SUPPORT W1TH 5x2x1/4" THK STEEL PLATE FASTENED TO SLAB WITH GONG. EXPANSION ANCHOR 5OLT5 2 NILTI 1/4" KWIK BOLTS L BEAD TAPE +# SPACKLE GYP5UM CAP L BEAD TAPE SPACKLE CONTINUOUS METAL STUD TOP RUNNER 5!8" TYPE 'X' GYP. BD. ON EA. SIDE OF 2-1/2" X 20 GA. MTL. 5TU05 @ 24" O.G. STUD CRIMPED AT HEAD TO RECEIVE TOP TRACK. STEEL TUBE SCHEDULED BASE SCHEDULED FLOOR COVERING i--- SEALANT CONTINUOUS METAL STUD FLOOR RUNNER SET BETWEEN FLOOR ANCHOR PARTITION TYPF " LOV1 PARTITION DE:TAIL 5/81' THK. TYPE '"X" -- GYP. BOARD (SEE PARTITION TYPE) Dt @ a „ c 44 a a`" o o" 4 T 4 -- 44, a Q a; a 4 4 a a a . ++ i P 50"' SCALE Cv'r'P. BD 5OFF I T r,>I=Tf t I L N.T.S. I I 1 WALL INHERE OCCURS I 1 EXISTING DOOR OR NEW TO MATCH EXISTING (SEE SCHEDULE FOR RATING) OR NEW TO MATCH EXISTING SCALE T'rP. DOOR .jAtM5 DETAIL N.T.S. 4 41, a 4 a e a e 4 . SCALE 10 N.T.5. SCALE C-�YP. BOARD 5OFF I T DETA I L NONE OLTS NISH CEI m ATTACH ALL BRACING TO UNI-5TRAUT SPAN BETWEEN STRUCTURAL I -BEAMS W/ BOLTS AS REQUIRED 2 I/2" X 20 6A, MTL. STUDS @ 24" O.G. W/ DIAG, BRACING TO STRUGT. @ 4'-0" O.G. STA66ERED - ATTACH TO 5TRUC'C._Y13.TH SHOT PINS 1" @24" O.C. THK. TYPE "X" GYP, BOARD I � P +41"-6 "' CONTINUOUS METAL CORNER BEAD SCALE N.T.S. f MTL. STUD, SEE ' PARTITION PLAN FOR SIZE t SPACING DBL. STUDS @ HEAD GYPSUM BOARD, TYP. (SEE PARTITION TYPE) EXISTING DOOR FRAME OR NEW TO MATCH EXISTING EXISTING DOOR OR NEW TO MATCH EXISTING (SEE "a -' SCHEDULE FOR RATING) 7YF. 1;)OOR HEA ZDFR DETAIL LATERAL SUPPORT SHALL BE PROVIDED BY (4) WIRES (12 6A. MIN) SPLAYED IN FOUR DIRECTIONS a04 APART. CONNECT TO MAIN RUNNER @ 2" MAX. FROM CROSS -RUNNER AND TO STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 4% FROM PLANE OF GEILIN6. INSTALL LATERAL SUPPORTS @ 12'-Q" INTERVALS EA. DIRECTION W/ FIRST POINT @ 4'-O' MAX. VERTICAL SUPPORT SMALL BE PROVIDED AS REQUIRED IN CHAPTER 4'1 OF THE UNIFORM BUILIN6 CODE. WITH THE ADDED REQUIREMENT THAT DISCOUNTINUOUS @ 8" MAX. FROM SUCH DISCONTINUITIES WHICH OCCUR WHERE GEILIN6 15 DISRUPTED BY A WALL, HANGER WIRE5 INSTALLED IN CONCRETE DECK, ENDS D45tf. LOOPED FOR ANGHORAG " , 1 t , a i i c 6i�'c�UN:) FLOOR SCALE Revisions NONE PSC IM LANDLORD REVIEW Iaj�ZQ5 L LSSUED FOR EN61NESIhg 1/,28/05 ISSUED FOR HEALTH DEPARTMENT 2/14/05 ISSUED FOR LL APPROVAL 2/14/05 A 15SUED FOR PRIGIN6 2/14/05 A ISSUED FOR PLAN CHECK 2/14/05 A PLAN CHECK CORRECTIONS 3/30/05 A HEALTH DEPARTMENT CORRECTIONS 3/30/Q5 A ISSUED FOR CONSTRUCTION L,.,.�____- AA - OWNERSHIP �_ _ OWNERSHIP AND USE OP DOCUMENTS All Prowings, Specifications and copies thereof furnlshed by JS G+D are and shall remain its property. They are to be used oniy with respect to this Project and are not to be used on any other project. Submission or distribution to most official reguiotory rogvirements or for other purposes in connection with the project Is not to be construed as publication in derogation of JB Concept+Design common law copyright or other reserved rights. Approved Drawn J.B. Reviewed J.B. 5/&" THK, TYPE "X" Project No. Dwg.File A'1,DW6 GYP. BOARD Scale Issue Date 1/28/05 5 6A. ANNEALED WIRWANGER @ 4'-O" O.C. SADDLE TIE 16 6A. 6ALV. ANNEALEPAIRE TIES 1-1/2" "BLACK IRON" CHANNEL @ 48" O.C. (DRILL FOR SEISMIC BRACING) U.S.G, METAL I/W FURRING CHANNEL @ 24" D.C. %,/ \ t I-1/2" GH�Ni4dEI?`ROEd6lER \ 5/8" THK. GY5UM BOARD Tr8" Fl�1�Nt9"C�I,$NNEL 6Y`P. SOALRD GF I L I NCB DETAIL SCALE A. 7 NONE V Sheet of 6" STAINLE55 5TEEL E3A5E CABINET 1N/ 51 NK FUD6F D I SPLAY YNI/SNEEZE GUARD BACKSPLA5H (WHERE OCCURS) SCRIBE TO WALL COUNTER TOP PER SCHEDULED FINISH SCHEDULED PULL SINK WHERE OCCURS SEE ENGINEER DRAWIN65 FOR SPEC. CABINET DOOR ON CONCEALED HIN6E5; (SCHEDULED FIN. ON BOTH SIDES) WITH INTEGRAL BASE ONE PIECE DOOR TO MEET ADA REO, PROVIDE CLEAR KNEE AND TOE SPACE (SHOWN DASHED, PER CODE). 6 EPDXY INTERIOR PER SCHEDULED FIN. CONTINUE SCHEDULED COVED BASE FINISH SCALE 4 N.T.S. 5 S/1 VER SOD :.E COVED NRY 5E SCALE N.T.S. 8" STAINLES5 STEEL BACKSPLA51 SCHEDULED PARTITION 5/4" DOOR IN. P-LAM ALL 51DE� P. LAM. OP 5/4" MOf 5HELf WHITE MELAMINE OP 3/ 4" MDf (INTERIOR WOOL BLOCKIN< A; RFejLjlRp-£ SEE ELEVATION5 a PLAN5 5/5 )P 7F 5/g 5/5 BACK5PI.ASH 5/5 OVER S/4" 5ACK5PLA5H / ML55. 8 OURTOP o 8 51DES BEYOND 5/5 OVER S/4" 5 L855I,-T�P N SIDES BEYOND MTL, BALL MTL. BALL BEARING BOLB. zt, N BEARING SOLE. CAPACITY PULL CAPACITY PULL O EXTENSION DRAMR EXTENSION DRAW R GLIDE P. LAM. ON 5/4" M 6L1DE P. LAM. ON 5/4" M ` HELP W/ ADJUSTAME SHELF IN/ AVJUSTA5L Ew RECESSED STANDAN D "jj RECESSED STANDA ZZ1T�_�� U Li ol WOOD BLOCKING WOOD BLOCKING AS REQUIRED AS RECUIRED NOTE: ADJUSTABLE 'AXIMAT' TYPE CONGEALED 180118 5WING HIN6E5 TO BE USED IXY COVED BASE I ALL MDF TO BE 45 LS.DENSIT'i' 5A5E GA F; I NET 5GALE N.T.5. 5/4" THK. STONE SLAB 5/1 IN/ 1 1/2" STRAIGHT EDGE OVER 5/4" PLY 6100V GUS :VICE: 6" co, :FOXY SASE CASHIER TRANSA CTION COUNTER 5GALEN.T.S. � 6" EPDXY COVED BASE BASE GA 51 NET YN/ 1�>RANFR SCALE 2 N.T.5. 8" STAINLESS 5TEELBAGK5PLA5H - SEE ELEVATION5 Q PLANS PEPTH S/5 OVER 5/4" i 45 LB5. DENSI'iY i MDF � O a TRASH OPENING E TO BE FINISHED PVC T-MOLD (BLACK) P. LAM, SURFACE T LENGTH OF ENTRY �C ELLIPSE INTERIOR CABINET MELAMINE ON 5/4" MDP i WOOD BLOCKING { A5 REQUIRED RECYCLE BIN { { BY G.C. �r 1 I 3/4" DOOR W! P-LA ALL 51 DES { 1 I { i { t 1 I NOTE: ADJUSTABLE 'AXIMAT' TYPE CONGEALED ISO HINGES TO BE USED ALL MDF TO BE 45 LB. DENSITY SASE CABINET TRA5H/RECYCLE 1DETAIL SCALE N.T.S. OPENING d a 1 I " 1 I I 1 i I 1 I I { I I I I 1 ! I I i L_ J NOTE: ADJUSTABLE 'AXIMAT' TYPE CONGEALED ISO!1e SWING HINGES TO BE USED ALL MDF TO BE 45 LB.DENSITY OPEN 5A5E GA 51NET ^/ PRA ^f=R 6" EPDXY COVED BASE a" STONE BACK SPLASH. 10" DIAM. _ 3/4"THK STONE 5LAB COUNTERTOP NOTE: ADJUSTABLE 'AXIMAT' TYPE CONGEALED ISO!1e SWING HINGES TO BE USED ALL MDF TO BE 45 LB.DENSITY OPEN 5A5E GA 51NET ^/ PRA ^f=R 6" EPDXY COVED BASE a" STONE BACK SPLASH. 10" DIAM. _ 3/4"THK STONE 5LAB COUNTERTOP DOOR PULL AS SCHEDULED W P. LAM. --1 CABINET DOORS BOTH 5lDES BACKING AS O REQUIRED REMOVABLE TRASH CAN BY OTHERS WHITE KORTRON CABINET INTERIOR PIN15H CONCEALED DOOR HINGE5 (2-PER DOOR) eCOVED BASE AS 5CHEDULED SCALE N.T.S. GON17) I DENT COUNTER $ BASE CABINET 5GALE NONE 1 51 1320 FAIRPLAIN AVE. W H ITTI E R, CA.90601 TEL.: 626- 369 3701 3 • Uj , i 4 r ,U. UJ 1 • t , , • i w c� LA,Q/ lNr:) FLOOR Revisions 1=0028 A ISSUED FOR EN61NEwRIN6 1/28/05 A ISSUED FOR HEALTH DEPARTMENT 2/14/05 A ISSUED FOR LL APPROVAL 2/14/05 SUED FOR PRiciN6 2/14/05 A ISSUED FOR PLAN CHECK 2/14/05 A PLAN CHECK GORREGTION5 3/50105 A HEALTH DEPARTMENT CORRECTIONS 3/50/05 A ISSUED FOR CONSTRUCTION A A A OWNERSHIP AND USE Of' DOCUMENTS All Drawings, Specifications and copies thereof furnlshed by is c+D are and shall remain its property. They are to be need only with respect to this Project and are not to be used on any other project. Submission or distribution to meet official regulatory regviromonts or for other pvrpoees In connection with the project is not to be construed as publication in derogation of -0 Concapt+Daeign common law r. p right or other reserved rights. Approved Drawn J.B. Revlewed J.B. Project No. AS.01/46 scale Issue Date 10/15/04 K L.L.V�OR.f<. ZaFTA I L.5 SCALE 12 SCALE i SCALE 10 SCALE" N.T.S. N.T.S. ") NONE NONE 91 Ae8 Sheet of PROJECT NAME DATE KELLY'S COFFEE & FUDGE ]:2/10/05 Y T iF ATURES SYSTEM NAME MECHANICAL SYSTEMS NOTE i t Hot Water Boller DHW Heater RESTAURANT TIME CONTROL FIELD. n/a n/a Programmable Switch SET13 CK CONTROL n/a n/a No Setback Re uired ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? n/a n/a Yes ELECTRIC HEAT? n/a n/a 0.0 kW FAN CONTROL n/a VAV MINIMUM POSITION CONTROL? n/a n/s n/a Constant Volume No SIMULTANEOUS NEAT/COOL? n/a n/a No HEATiN SUPPLY RESET n/a COOLING SUPPLY RESET n/a n/a Constant Tem HEAT REJECTION CONTROL n1a n/a Constant Temp n/a n/a VENTILATION n1a OUTDOOR DAMPER CONTROL n/a ECONOMIZER TYPE n/a DESIGN O.A. CFM MECH-3 COLUMN I n1a n/a n/a n/a n/a Air Balance Gravi ty No Economizer 367 cfm Heat Pum HEATING EQUIPMENT TYPE Gas Fired Electric Res HEATING EQUIPMENT EFFICIENCY 80% 99% 7.60 HSPF COOLING EQUIPMENT TYPE n/a n/a S lit DX COOLING EQUIPMENT EFFICIENCY n/a n/a 10.6 SEER / 9.4 EER MAKE AND MODEL NUMBER unde coed MOR-FL�/A E. FICSF C52 EXISTING FAN COIL PiPE INSULATION REQUIRED? Yea PIPEIDUCT INSULATION PROTECTED? Yes Yes Yes Yes Yea HEATING DUCT LOCATION R-VALUE n/a n/a COOLING DUCT LOCATION R-VALUE n/a n/o n/a Ducts in Attic 4.2 n/a n/a n/a Duds in Attic 4.2 No n/a VERtFtED S�L D DUCTS ill CEILI /RO PACE n/a CODE TABLES: Enter code from table below Into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of I: inlet Vanes VAV MINIMUM POSITION CONTROL? O: Occupancy Sensor C: Cooling B: Both Isolation Zones. P: Variable Pitch —...SIMULTANEOUS HEAT / COOL? Y: Yes M: Manual Timer V: VFD O: Other C: Curve HEAT AND COOL SUPPLY RESET? N: No VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance A: Auto A: Air Enter utdoor Air PIPE INSULATION REQUIRED? C: Outside Air Cert. G: Gravity W: Water CFM. PIPE/DUCT INSULATION PROTECTED? M: Out. Air Measure D: Demand Control N: Not Required Note: This shall be no SEALED DUCTS IN CEILING/ROOF SPACE :Natural EC: Economizer Control See Section less than Col. H on MECH-3. 144e3 ° EnergyPra 3.1 9y EnergySoft User Number: 1919 Jab Number: L05i46 Page:7 of 17 PROJECT NAME DATE - KELLY'S COFFEE & FUDGE 2/10/05 DESCRIPTION Equipment and Systems Efficiencies ® § 111 Any appliance for which there Is a California standard established In the Appliance Efficiency Regulations will complywith the applicable standard. L!di § 115(a) Fan type central furnaces shall not have a pilot light. § 123 Piping, except that conveying fluids at temperatures between 60 and 106 degrees Fahrenheit, or within HVAC equipment, shall be insulated In accordance with Standards Section 123. § 124 Air handling duct systems shall be Installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be Installed with one of the following: § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be Installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power Is interrupted; or § 122(e)1B An occupancy sensor to control the operating period of the system; or Q§ 122(e)1C A 4-hour timer that can be manually operated to control the operating period of the system. JAI § 1221e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. E] § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 26,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with Isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off Independently of other Isolation areas; and shall be controlled by a time control device as described above. § 122(a&b) Each space conditioning system shall be controlled by an Individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling Is shut off or reduced to a minimum. X§ 122(c) Thermostats shall have numeric setpoints In degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be Installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. —EnergyPro 3.1 By EnergySoft User Number:1919 Job Number L05146 Enforcement of 17 r!!!� DATE ELLY'S COFFEE FUDGE _ __ 2/10f05 DESCRIPTION ner Enforcerr _ § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply ' with the California Quality Standards for insulating material, Title 20, Chapter 4„ Article 3. FX] § 118(c) All insulating Materials shall be Installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2, § 117(a) All Exterior Joints and openings in'the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. § 116(b) Site Constructed Doors, Windows and Skylights shalt be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). I § 116(a)1 Manufactured Doors and Windows installed shall have air Infiltration rates not exceeding those shown In Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U-value according to NFRC procedures. I § 118(e) Demising Waits in Nonresidential Buildings: The opaque portions of framed demising walls In nonresidential buildings shall have Insulation with an installed R-value of no less than R-11 between framing members. l EnergyPro 3.1 By EnergySoft User Plumber: 191$ Job Number: L05148 - ��""'�""" ._ _ . Page:11 of 17 t MECHANICAL MANDATORY MEASURES Part 2 of 2 MEDH- M PROJECT NAME MATE KELLY'S COFFEE &FUDGE � _ 2/10/05 Descri tion ~_� Designer Enforcement Ventilation 0 § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. § 122(f) Gravity or automatic dampers Interlocked and closed on fan shutdown shall be provided on the outside air Intakes and discharges of all space conditioning and exhaust systems. j x § 122(t) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers In all openings to the outside, except for combustion air openings. FX�§ 121MI Air Balancing: The system shall be balanced In accordance with the National Environmental Balancing Bureau (NESS) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or JAI § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the Installing ficenced C-20-mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or ❑ § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated focal or --...._ _... _ remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121(1)4 Another method approved by the Commission. Service Water Heating Systems.—.. JAI § 113(b)2 If a circulating hot water system Is installed, It shall have a control capable of automatically turning off the circulating pump($) when hot water is not required. i Q § 113(b)38 Lavatories In restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. Ful JAI § 113(b)3C Lavatories In restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.6 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.76 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum:of 0.75 gallons per minute. Self -closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-efosing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self -closing valves,,and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 S Energ Soft User Number: 1919 Job Number: L05148 Page:13 of 17 i �,-- EAE EtE 20 FAIRPL_AIN AVE. -1ITTIER, CA.90.601 L.: 62.6-- 369" 3701 a ti N LLJ 1,/ U_ - * rk Z 0 - E W f y Ptaat LL Z< CC Z Z iCt ' Ci A -A C _K3 + S ReVi sions u t � f -\ OWNERSHIP AND USE OF DOCUMENTS All Drawings, Specifications and copies thereof furnished by J8 Concept+0esign are and shall remain its property. They are to be used only with respect to this Project and ore not to be used on any other project. Submission distribution to meet official regulatory requirements or for other or purposes in connection with the project is not to be construed as publication in derogation of JB Concept+Design common low copyright or other reserved nigh::,- Approved Drawn T. L. Reviewed Project No. L 0 514 6 Dw,g.File 1 t Scale Issue Date 02.41-05 Bc MANDATORY MEASURES ) i' Sheet of