Loading...
HomeMy WebLinkAbout10147877.pdfF- 0 SIZE WINDOW TYPE ^� 4',-0" X 4'-011 DUAL GLAZED, TEMPERED GLASS. ALUMINUM SLIDING WINDOW OPENING MEETS EGRESS REQUIREMENTS. f � 31-011 X 1'-011 DUAL GLAZED, TEMPERED GLA55. ALUMINUM SLIDING WINDOW. NEW GLAZED OPENINGS WILL BE LABELED TO INDICATE A CERTIFIED U-FACTOR OF .'75 4 50LAR HEAT GAIN COEFFICIENT OF .40 PER TITLE 24. ALL GLAZING SHALL BE IN ACCORDANCE WITH 05G CHAPTER 24. SIZE DOOR TYPE {'' j� 50LID GORE EXTERIOR PAINT GRADE WOOD `�...�./ DOOR. GLAZING TO BE TEMPERED W/ PANES. 2'-8" X V-6" HOLLOW GORE PAINT GRADE WOOD .i 2 DOOR.. FURNISHED 8 INSTALLED BY OWNER ( 21-6" X 6'-8" HOLLOW GORE PAINT GRADE WOOD �_--' DOOR. FURNISHED 4 INSTALLED BY OWNER (2)-2'-b" X V-8" ALUMINUM SLIDING TEMPERED GLASS SLIDING MIRROR DOORS. FURNISHED 4 INSTALLED BY OWNER FLOOR PLAN NOTES: i. PROVIDE NEW 120V (WITH BATTERY BACK UPWIRED ) SMOKE DETECTOR. BATTERY OPERATED SMOKE DETECTORS PERMITTED IN EXISTING RESIDENCE. 2. LOCATE SMOKE DETECTORS IN BEDROOMS AND HALLWAY5 OR ADJACENT ROOMS LEADING TO BEDROOMS. SMOKE DETECTORS TO BE HARD WIRED IN NEW CONSTRUCTION Al BATTERY SACK -UP 4 AUDI5LE INA ALL SLEEPING AREAS. MAY BE 50LELY BATTERY OPERATED IN EXISTING HOUSE. 5. 5HOWERMB DOORS SHALL BE TEMPERED. 4. NEW BEDROOMS EXCEPT BATHROOMS, KITCHENS AND LAUNDRY ROOMS REQUIRE NATURAL VENTILATION BY MEANS OF EXTERIOR OPENABLE WINDOWS OR 5K'fL.IGHT5 a MOTH THE FLOOR AREA OF THE ROOM, OR 10 S.F. MIN. WHICHEVER 15 GREATER. 5. NEW BEDROOMS SHALL HAVE A MIN. 20" CLEAR WIDTH, 24" CLEAR HEIGHT AND 5.1 50. FT. MIN. OPENA5LE AREA FOR EGRESS. (GBC 510.4) E,. PROVIDE WATER RESISTANT GYP. BACKING BOARD AS A BASE FOR TILE OR WALL PANELS -I0" MIN. HGT ABOVE FIN. FLOOR FOR TUB OR 5HOWER. ENCLOSURES OR WATER CLOSET COMPARTMENT WALLS. SEC. 2512 -1. PROVIDE SAFETY GLAZING IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING 15 AITHIN 24" ARC OF EITHER VERTICAL. EDGE OF THE DOOR IN A OL05ED POSITION d WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 19 LE55 THAN 60" ABOVE THE WALKING SURFACE. g ALL PLUMBING FIXTURES TO BE SELECTED 4 INSTALLED BY OWNER. al. NEW BATHROOM TO HAVE FLOURE5GENT LIGHTING. 10. ALL DIMENSIONS ARE TO FACE OF STUD UNLE55 NOTED OTHERWI5E. 11. ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE PHASE, 15-20 AMPERE RECEPTACLE OUTLETS INSTALLED IN BEDROOMS SHALL BE PROTECTED BY AN ARC. -FAULT INTERRUPTERS) PER SECTION 210-120 OF THE 2001 C.E.G. 12. TOILET5 SHALL USE NO MORE THAN 1.6 GALLONS PER FLUSH. 15. GLAZED WARDROBE DOOR5 5HALL MEET THE IMPACT TEST REQUIREMENTS OF UBC 57D. 24-2. PART 2. LAMINATED GLASS MUST AL50 MEET THE 501 L TEST REOUIREMENT5 OF U50 57D. 24-2 PART 2. 14. ALL NEW GLAZING SHALL COMPLY W/ 5TANDARD5 OF THE U.S. CONSUMER PRODUCT SAFETY COMMISSION. MANUFACTURERS TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER. APPLIC65I.E CODE5: 2001 CALIFORNIA BUILDING CODE (050) 2001 CALIFORNIA ELECTRICAL CODE (CEC) 2001 CALIFORNIA MECHANICAL CODE (CMG) 2001 C AL I FORN I A PLUMBING CODE (CPC) ENERGY CODE (T24-6) GLAZING INFORMATION: GLAZING ALLOWED: 41-18 X 20% = qa SO. FT. + GLAZING REMOVED = a 50. FT. TOTAL ALLOWED = 10550. FT. TOTAL PROP05ED = 61 50. FT. NEW 2X WOOD FRAME WALL5 EXISTING 2X4 WOOD FRAME WALLS EXISTING 2X4 WOOD FRAME WALLS TO BE REMOVED MEDICINE CAB. EXHAUST FAN, 5 AIR CHANGE5/HOUR MIN., TYP. 2x6 PLUMBING WALL A" SLOPE TO 5HOAER FLOOR DRAIN RECESSED MEDICINE CABINET. 1/4" MIRROR, PROVIDE 6" COUNTER SPLASH. PLUMBING PIPE VENT THROUGH ROOF. k nt E FLOOR 4 SHOWER WALLS. 4 1 IWA AM71 r! 41mm'01*11ai k L 1/2• - 1' 0 EXISTING WOOD PATIO TO REMAIN UPGRADE EXISTING ELECTRICAL METER TO 200 AMP SERVICE. -.Ek5TING • DRIVEWAY EXISTING SIDEWALK 4701 FLIGHT AVE. AREA TABULATION: TOTAL LOT AREA: _ -1,150 50. FT. EXISTING SINGLE FAMILY RESIDENCE: = 1000 50. FT. I GAR GARAGE: = 21050. FT. EXISTING TOTAL AREA = 1,210 50. FT. ADDITION AREA = 498 50. FT. TOTAL ALLOWED: 50% LOT AREA (1150) = 5 575 50. FT. TOTAL PROPOSED = 1,7105 50. FT. i Drawn by Anibal Vargas 6271 Marshall Ave. Buena Park, CA 90821 714.280.6170 47 I 2/25/05 - PLAN GHEGK GOMMENT5 1 • Uj c 1*0 m • i LL- UL CID • .,m +r■► IF- Cfj ILL - �■r CC • cod i_ LEGAL DESCRIPTION, N TR. 2969, ELK LOT 79 UN A.P.N. a 108-351-06 NORTH CABRERA ADDITION SHEET NO: 4701 W. FLIGHT AVE. SANTA ANA, CA 92704 '' I I A 114'ro m rMum NEW ALUMINUM SLIDING WINDOWS TO MATCH EXI5TIN6, TYPICAL j- NEW COMPOSITION SHINGLE ROOF, OVER 1-50 LB. LAYER OF FELT. NEW ROOF TO BE MINIMUM CLASS "A" ICBO APPROVED ROOFING. ROOF COLOR TO MATCH EXISTING. i I I FN61 F1 Zj F1 r77- L Ex151Ns NrzVi EAST ELEVATION I. VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE BEFORE STARTING CONSTRUCTION 2. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR AND SUB -CONTRACTORS TO SATISFY THEMSELVES AS TO THE SITE CONDITIONS, DIMENSIONS, AND TO COMPLY WITH ALL BUILDING CODES IN FORCE. COMMENCEMENT OF WORK BY ANY SUBCONTRACTOR PRE5UME5 ACCEPTANCE OF PRIOR WORK, PLANS, 4 CONDITIONS AFFECTING H15 FUNCTION. NO ALLOWANCE SHALL BE MADE FOR ERRORS RE5ULTING FROM FAILURE TO IN5PECT SITE, PLANS OR WORK IN PROGRESS. 5. ALL PLUMBING WORK SHALL BE DONE IN ACCORDANCE Y41TH THE UNIFORM PLUMBING CODE 4. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE 5. ALL LATHING, PLA57ERIN6, AND DRYWALL SHALL BE DONE PER SECTION 2506 OF THE UNIFORM BUILDING CODE. 6. UNLESS NOTED OTHERWISE, ALL HORIZONTAL FRAMING LUMBER SHALL BE NO. I DOUGLAS FIR, VERTICAL FRAMING LUMBER SHALL BE NO. 2 DOUGLAS FIR. P05T5 SHALL BE NO. I DOUGLAS FIR. CONNECTORS 5HOWN ARE TO BE "51MP50N" OR APPROVED EQUAL. 'I. NOTCHING OF STUDS IN BEARING WALLS SHALL NOT EXCEED 25% OF THE WIDTH. 8. NOTCHING OF STUDS IN NONBEARRING WALLS SHALL NOT EXCEED 40% OF THE WIDTH. a. BORED HOLES IN 5TUD5 IN BEARING WALL5 SHALL NOT EXCEED 40% OF THE WIDTH. 10. BORED HOLES IN STUDS IN NONBEARIN6 WALL5 SHALL NOT EXCEED 60% OF THE WIDTH, UNLESS THE 5TUD5 ARE DOUBLED AND NO MORE THAN SUCH SUCCESSIVE DOUBLED 5TUD5 ARE 50 BORED. 11. BORED HOLES MAY NOT BE LOCATED OL05ER THAN 5/8" TO THE EDGE OF THE STUD AND MAY NOT BE LOCATED IN THE SAME AREA AS A CUT OR NOTCH. 12. ALL ROOF FASTENERS SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. 15. WHERE TOP PLATES OR 50LE PLATES ARE CUT FOR PIPES, A METAL TIE MIN..058" THICK 4 1 1/2" WIDE SHALL BE FASTENED TO EACH PLATE ACROSS 4 TO EACH 51DE OF THE OPENING WITH NOT LESS THAN 6-16d NAILS. 14. PROVIDE DOUBLE TOP PLATE W/ MIN. 48" LAP SPLICES. SEC. 2520.11.2. 15. FIRE BLOCKING, VERTICAL OR HORIZONTAL, SHALL CONFORM TO SEC. '706.2. I&. STUCCO LATH SHALL BE FASTENED IN/ NO. 16 GA. STAPLES WJ 1/8" LONG LEGS OR NO. If GA. NAILS, 1-1/2" LONG W/ "t/16" DIA. HEADS. 1-1. ROOFING MATERIAL WILL HAVE A MINIMUM CLASS "A" FIRE RATING. 18. GALVANIZED SHEET METAL (28 &A. MIN) ROOF VALLEY FLASHING 15 REQUIRED. (1508.5) 141. SPECIAL INSPECTIONS REQU I RED BY 100 RESEARCH REPORTS SUCH AS FOR EPDXY. 20. PORTLAND CEMENT PLASTER (STUCCO), GYPSUM LATH AND GYPSUM WALLBOARD SHEAR WALL5 SHALL COMPLY WITH CBC SECTION 2515 AND TABLE 25-I. 21. PIPES, DUCTS AND OTHER NONSTRUCTURAL CONSTRUCTION SHALL NOT INTERFERE WITH ACCE591BIL17Y TO OR WITHIN UNDERFLOOR AREA. (2506.5). 22. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE OF GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. 25. RAFTER TIES SPACED 4' MAX. ON CENTER ARE REQUIRED IMMEDIATELY ABOVE CEILING JOISTS WHICH ARE NOT PARALLEL TO THE RAFTERS. 24. ROOF PURLIN5 MUST NOT BE SMALLER THAN THE RAFTERS THEY SUPPORT. THE MAXIMUM SPAN FOR 2x4 / 2x6 ROOF PURLIN5 15 4 FEET / 6 FEET. FOR THE PURLIN SUPPORTS PROVIDE STRUTS NOT SMALLER THAN 2x4 W/ AN UNBRACED LENGTH NOT MORE THAN 8 FEET 8 NOT FLATTER THAN 45 DEGREES FROM THE HORIZONTAL TO BEARING WALLS. CBC 2520.12.-1 25. ALL ANCHOR BOLTS 4 HOLDOWN5 SHALL BE TIED IN PLACE PRIOR TO FOUNDATIQN INSPECTION. 26. ALL W1 � WOOD CONSTRUCTION SHALL COMPLY WITH CODE SEC. 2520 & MIN. NAILING W/ CODE TABLE 25-II-8-1 ME P, SIMPSON MST24 METAL STRAP EXI5TIN6 PLATE TO NEW. NORTH I TO ROOF x4HE ALL NEW WINDOWS, WINDOW TRIM, ROOFING MATERIAL 4 COLOR, STUCCO FINISH #- COLOR TO BE CONSISTENT THROUGHOUT EXISTING RESIDENCE 4 ADDITION. 5 5 %}� TO ROOF 5/6" VIA. AB. a 24" O.G. i\ i n..' @ �I. J ■i • 'I Ns- A ►� 2x6 CEILING R I JOISTS a 16" D.G. ri v x 0 - 5 � I :fl X4 POST 6�C 3 Q c) x :.i cV U A t Z44 i 2x 1-- 0 STUCCO FINISH. TEXTURE AND COLOR TO BE CON515TANT THROUGHOUT EXISTING RESIDENCE 4 ADDITION t 1 0 'I► HV2A 4x4P. � Q 2 X RIDGE 11 I 5 5 A HV2A + 52 44xx 4 P. � I '4/ cv TO x 4 x'12 #1 SM. POST *-" - 'T - M5TA15 STRAP, 14 A ONLY EXISTING ROOF RIDGE GALVANIZED 1/4" CORROSION RES15TANT ATTIC VENT, TYP. WEST ELEVATION SHEAR WALLS: 5/6" PLYWOOD, 5TD. SH 71`6 Wl 8d a 6" O.C. AT EDGES AND 12" O.C. FIELD. 516" VIA. ANCHOR BOLTS 24" O.C. "7/8" STUCCO OVER PAPERBACKED LATH, 16 GA. STAPLES a 6" O.C. EDGES 4 FIELD ROOF SHEATHING: 15/52" THICK CD-X PLYWOOD P.I. #24/0 MIN. UNBLOCKED NAILING: 8d COMMON AT: BN: 6" O.G. EN: 6" O.C. FN: 12" O.C. FOOTING 50HEDULE: CONTINUOUS FOOTING = 12" WIDE x 12" DEEP IN/ 1- #4 TOP 4 BTM. U.N.O. CONCRETE TO BE 2500 P51. REBAR TO BE #4. FOUNDATION NOTES: I, USE 5/5" DIA. ANCHOR BOLTS EMBEDDED T' INTO CONCRETE. 2. USE PLATE WA5HER5 W/ A MIN. OF 2"x2"x5/16" THICK AT EACH ANCHOR BOLT IN SHEAR WALL5. 5. CONCRETE FLOOR SLABS ON GRADE SHALL BE PLACED ON A 4" FILL OF COARSE AGGREGATE OR ON A MOISTURE BARRIER MEMBRANE. THE SLAB SHALL BE AT LEAST 5-1/2" THICK AND SHALL BE REINFORCED WITH WIRE MESH AT CENTER OF SLAB. 4. USE Ibd COMMON NAILS AT BOTTOM PLATE NAILING. SPACING = (IO5x1.55x12)/(A0TUAL WALL SHEAR) IN INCHES. 5. PLYWOOD SHEAR PANELS SHALL BE MIN. GRADE CD W/ EXTERIOR GLUE. AND SHALL BE NAILED Al COMMON NAILS AT ALL EDGES AS NOTED AND NAILED AT 12" O.C. AT INTERMEDIATE FRAMING MEMBERS. NEW COMP051TION SHINGLE ROOF, OVER 1-50 LB. LAYER OF FELT. NEW ROOF TO BE MINIMUM CLA55 "A" ICBO APPROVED ROOFING. ROOF COLOR TO MATCH EXISTING. lal-5ii a1-1 l 5/5" DIAL. A.B. 24" O.G. I1- fit t?to RIFY LOCATION or - PLUMBING 4 CONNECTIONS",. H02A ; i TO EXISTING SEWER. 4 x 4 P. 5 TYP. @1 a HD2A N 5-1/2" THICK CONC. SLAB OVER 4 x 4 P. 2" MIN. SAND -FILL 4 10 MIL 9 V15QUEEN WI 6X6/IOXIO WIRE 5 TYP. MESH * CENTER OF SLAB. POUR 4�_� OVER EXIST. SLAB. 2 A Bja OLTS d1 A 5 3 ` ' HD2 4 P. HV 4 x P. 5 5 5 Drawn bys Anibal Vargas 6271 Marshall Ave. Buena Park, CA 90621 714.260.6170 PROJECT N0. 04-06 DATE: 1/17/05 DRAWN BY: A.VARGAS SCALE: AS NOTED REVISIONS= 1 2/25/05 - PLAN CHECK COMMENTS SHEET TITLE - FOUNDATION, I=RAM I NCB PLAN5, r-LEVATION5 4 NOTE5 Il■ a i � ..(owl .s r � SCALE, 1/4* - T-Ow SCALE, 1/4• - T-O" 2x CONT. BLOCK'& rv/ LTP4 ROOF - O.C. r — __ I �_ W_ . Ad day 12, R-IcT BATT INSULATION, TYP. — RIDGE PER FRAMING PLAN 12 J�4 MATCH EXISTING DRILL 5/6" VIA. X 6" DEED' HOLE f 1 •? n 6 �, ; AT EASTIN6 CONT. FOOTING 4 APPLY SIMP50N "SET' EPDXY AFTER DOWEL 15 IN PLACE. NEW SLAB TYP. #4 DOWEL AT 24" O.G. � 7�e ISTING FOUNDATION SLAB TO EXISTING mr=TG DRILL 5/6" VIA. X 6" DEEP HOLE AT EXI5TIN6 CONT. FOOTING 4 APPLY 5IMP50N "SET' EPDXY `-- NEW CALIFORNIA T FRAMING, TYP. NEW RAFTERS E.N. EXISTING PLYWOOD PER PLAN SHEATHING SHEAR WALL AFTER DOWEL 15 IN PLACE. NEW ROW OF CONT. x TYP. #4 DOWEL AT 24 O.G. SHAPED BLOCKING SIMPSON LTP4 E.N. EXISTING FOUNDATION ANCHORS 0 16" O.G. NEW FTG. TO EXISTING FTG. SCALE, 1 1/2' - 1-0' Im 4x P05T PER PLAN SIMP50N HOLD DOWN PER PLAN 2x P.T. SILL PLATE, TYP. 2x PLYWOOD SHEAR PANEL ON EXI5TING 2x RAFTERS, EXI5TING STUDS (WHERE NP' OCCURS), TYP. 8 NEW ROOF AT EXISTING ROOF 4 SCALE 1 1/2' - 1'-0' ROOF SHEATHING 2X4's AT 24" O.G. FLAT, TYP.-� U E.N. U 4, NEW FOOTING _ 'k- ° ° 2 X RAFTER5 2 X RAFTER5 4 ° 4. 24" Q.G. 24" O.G. SIMPSON LTP4 ANCHORS a+ 24" O.G. 4 DOUBLE 2X4 TOP ° ° 4 ° .4 PLATES PLYWOOD SHEAR PANEL (WHERE OCCURS), TYP. 4 DOUBLE 2X4 TOP 4 ° 4 PLATES 4 ° d . d 1/2" &YP. BD. 0/ 2 x 4 STU 5 AHr-F;M OCCURS. VA [*"A Us 4 !16 lmiAi • N3 1:211 PER PLAN INTERIOR FOOTING C:C°Al G. i 1/09 . 2x 4 STUD WALL (SEE PLAN) OARS(ALL <8> 5EE P1�AN) 2X4 PRESSURE TREATED D.F. SILL PLATE W/ 10" ANCHOR BOLT (SEE PLAN FOR SIZE 4 51FACI NG), EMBEDDED 1" INTO CONCRETE. USE 2 "x2 "x5/I6" PLATE WASHERS. WIRE MESH AT CENTER OF CONC. SLAB, REFER TO FOUNDATION PLAN (1) #4 TOP AND BOTTOM N t=A 2x4 5TUD5 a 51 MP50N METAL E NE1N IDOL PLATES EXISTING 2x4 5TUI M5T-2 ,TRAP tj 15LE 2X4 TO 16d 4" �5 12 l Z- _1� =a. , P_ A P B.N. < — 2x FASCIA BOARD E.N. SIMPSON LTP4 ANCHORS® 24" Q.G. — PLYWOOD SHEAR PANEL (WHERE OCCURS), TYP. 'SIMPSON" LSTA24 a 48" O.G. BOUNDARY NAILING, TYP. ASPHALT SHINGLES OVER 50 LB. LAYER OF FELT 2 X ROOF RAFTERS ® 24" O.G. =,p..;=...ram• % 5IMP5qN A54 EACH SIDE, 7yp. j4x4AS SHOWN QN G PLAN N LTP4 EA. SIDEd x 1 1/2" EA. END 2 X CEILING JOISTS PER FRAMING PLAN NEW WALL TO EXISTING 6 TYPICAL RIDGE 2 EXTERIOR CEMENT PLASTER 0/ 50# BUILDING PAPER 0/ PLYAOOD SHEATHING SCALE, 1 1/2' - 1-0' SCALE- 1 1/2' - 1-0' R-15 BATT INSULATION 2X4 STUD WALL, TYP. 2 X ROOF RAFTER5 12 PER PLAN SHEAR PANEL WHERE ROOF 5HEATHIN6 AT CALIFORNIAASPHALT SHINGLES OVER 30 LB. OCCURS, TYP. FRAMING ' `� LAYER OF FELT, TYP. 2X4 PRESSURE TREATED D.F. SILL PLATE IN/ 10" ANCHOR 80LT (SEE PLAN FOR SIZE 2 X CONT. A/ 2-I6d @ 24" O.G. 2" DIA. VENT MOLES - 2 PER SPACING), EMBEDDED "1" INTO NAIL. TO RAFTER. TYR. BLOCK a EVERY RAFTER BAY CONCRETE. USE 2 "x2 "x5/16" B'N' f . PLATE WA5HER5. 5-16 .TWEEN &LNG. STUCCO SCREED ! 1 J5T5. 4 TYP. NATURAL AND/OR FINISH GRADE GATT lWc41LATION -- 2X CEILING J 5 a OPTIONAL CONSTRUCTION JOINT 12" DEEP X 12" WIDE FOOTING A/ #4 REBAR a TOP 4 BOTTOM A TYPICAL EXTE RIOR FOOTING 9 CALIFORNIA i + 19K(ToMrs TYP. A35 ® 24" O.G. 2 X DOUBLE TOP -. PLATE, TYP. R-13 BATT INSULATION 1/2" GYP. 50. O/ 2 x 4 WOOD STUDS a 16' O.C. TYPICAL SAVE SCALE 1 1/2' - 1-0' 161, O.C. (PER N) - 2 X CONT. BLOCKING, T`r'P. - EXTERIOR CEMENT PLASTER 0/ 2 LAYERS GRADE "0" PAPER 0/ PLYW000 SHEATHING - SHEAR WALL WHERE OCCURS Drawn by, Anibal Vargas 8271 Marshall Ave. Buena Park, CA 90621 714.260.6170 PROJECT NO. 04-06 ,DATE 1/17/05 DRAWN BY: A.VARGAS SCALE AS NOTED REVISIONS- 1 2/25/05 - PLAN CHECK COMMENTS SHEET TITLE DETAILS, NOTES 8 Gf2055 SECTION .. • • 4M .s �r r�r � • • F L Mandatory Measures Checklist: Residential (Page 1 of 2) MF-lR NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk W may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shalt be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable, DESIGNER ENFORCEMENT Building Envelope Measures 150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturer's labeled R-Value. X 150(c); Minimum R-13 wall insulation in wood framed walls or equivalent U-value in metal frame walls (does not apply to exterior mass watts). Elx 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. 150(l): Stab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. FV__1 118; Insulation specified or installed meets insulation quality standards. Indicate type and form. I A I 121 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfittration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have (abet with certified U-Factor, certified Solar Heat Gain Coefficient (SHGQ and infiltration certification. 3. Exterior doors and windows weatherstripped, all joints and penetrations caulked and seated. E] 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 11 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. El150(e)-. Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory-buitt fireplaces have, a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures 110-13; HVAC equipment, water heaters, showerheads and faucets certified by the Commission. 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. 1500): Setback thermostat on all applicable heating and/or cooling systems. r_v_1 150(j): Pipe and Tank Insulation LA J 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. ,EnergyPro 3.1 By EnergySoft User Number- 2299 Job Number: 050228 Page: 5 of 14 Mandatory Measures Checklist: Residential (Page 2 of 2) MF-1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk W may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) Lry- I . 150(m): Ducts and Fans 1. All ducts and plenums installed, seated and insulated to meet the requirements of the 1998 [ME Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be seated with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, ULISIA, or UL161B. If mastic or tape is used to seat openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shalt not be seated with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than seated sheet metal, duct board or flexible duct shalt not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be seated With cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shalt be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 114, Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between fitter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between fitter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 0 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot - 150 Btu/hr) 118 (f): Coot Roof material meet specified criteria Lighting Measures F] 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shalt be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. FX1150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 tumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 1501102.; and recessed ceiling fixtures are IC (insulation cover) approved, 1 3.1 By EnergySoft User Number: 2299 Job Number: 050228 Page: 6 of �14 Certificate of Compliance: Residential (Part 1 of 2) CF-1R CABRERA RESIDENCE ADDITION 2/23/2005 Project Title Date 4701 Haht Avenue Santa Ana Project Address Building Permit # ANIBAL VARGAS (714) 260-6170 Plan Check / Date Documentation Author Telephone Computer Performance 8 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 1 .498-f? Average Ceiling Height: IQ ff Total Conditioned Stab Area: 1 498 f? Building Type: (check one or more) FX1 Single Family Detached ❑Addition F] Single Family Attached Existing Building El Mutti-Family FV_01 L/-\j Existing Plus Addition Front OrientationSouth) 180 deg- Floor Construction Type: Stab Floor Number of Dwelling Units: i _Qk Number of Stories: - 1 ❑ Raised Floor Const. Coonen mpt Frame Assembly Location/Comments a TvDe U-Vatue (attic, garage, typical, etc.) Stab On Grade A/a 0.756 Covgred Stab w/R-0.0 Perimeter Insulation Default Wall Prior to 1978 W ood 0.385 Exterior Wait Default Roof 1978 to Present W ood 0,047 Exterior Roof R-13 Walt (W.13.2x4,16) W ood 0.088 Exterior Watt 1-30 Roof JR.30.2x6.161 W ood 0.035 Exterior Roof I LVILl I MM I IVII )HdUt11k4 UtVlLttJ Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U-Factor SHG Shadinci Yes / No Yes / Nc Front (South) 5 0 1.28 0.83 BuaSGreen El 2 1:1 El Left ()lest) 28.5 1.28 %83 Bug Screen El Q 1:1 0 Rgar (NgEth) 16.0 1.29 0.83 Bug Screen R RX Left (West 3.0 0,87 0.70 Bug Screen X1 El F El El ❑ Rear (North) 19.0 0.87 0.70 Bug Screen El rX1 1:1 10 Right (East) BQ.Q H5 _xm_ Bug-, GrPen El FX I F1 El 11 11 El El R 1:1 El 0 F1 F1 D El El 1:1 0 El 11 1:1 R R ❑ 11 11 11 El =01 Im. : (Part 2 of 2) CF-1R CABRERA RESIDENCE ADDITION 2/23/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load, Distribution Heatiw Equipment Minimum Type and Duct or Type ( urnace, heat Efficiency Location Pipin Thermostat Location I pump , etc.) (AFUE/HSPF) (ducts, attic, etc.) R-Value Type Comments Fan Type W;;1I_EUCaacZ_ 60% AFUE QtjrtIP-,4z / with FaD __J1La__ k Exis�vqfpm ni-ral Eurnaca 65% AEUE Ductlpsq / with F;in D/a Nn 1CLath;irk NeW Fnrnare Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap, cooling) (SEER) (attic, etc.) R-Value Type Comments No Cootina _11&_sffs_ ntirtips_q DLaNn Cathnrk Exisiinn_',",v�+Aln No 1Q12IiOQ In A EFF2 DtlfflesS Za No Sp+hArIg Now Ftirnnra WATER HEATING SYSTEMS Rated Tank Energy Fact.' PC External Water Heater Water Heater Distribution # in Input Cap. Or _ ovary Standby Tank Insul System Name Type Type Syst. Btu/hr (gat) Efficiency Loss W R-Value I For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts I and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct seating and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Title/Firm: MR & MRS. CABRERA Title/Firm: ANIBAL VARGAS AddresS: 4701 Flight Avenue Address. 6271 Marshall Avenue Santa Ana. (A Buena Park, CA 90621 Telephone- (714) 418-1896 Telephone: (714) 260-6170 Lic. #: (s- e) (date) (signature) (date) Enforcement Agency Name: Efrain Olivas Title/Firm. ADVANCED TITLE 24 Address: 1235 N Harbor Blvd, Suite 235, Fullerton Telephone: (714) 525-9824 (siqna re/staMD) (date) IEnerqyPro 3.1 By EnergySoft User Number. 2299 J-66 Number: 050228 Paue; 4 of 14 1 Drawn by. Anibal Vargas 6271 Marshall Ave. Buena Park, CA 90621 714.260.6170 PROJECT NO. 04-06 DATE: 1/17/05 DRAWN BY: A.VARGAS SCALE. AS NOTED goo I - I SHEET TITLE: LLJ < CO 0 co Co CD < U 00 < < C) < r-_ -.;4- V) IN