HomeMy WebLinkAbout10147877.pdfF-
0
SIZE
WINDOW TYPE
^�
4',-0" X 4'-011
DUAL GLAZED, TEMPERED GLASS. ALUMINUM SLIDING
WINDOW OPENING MEETS EGRESS REQUIREMENTS.
f �
31-011 X 1'-011
DUAL GLAZED, TEMPERED GLA55. ALUMINUM SLIDING
WINDOW.
NEW GLAZED OPENINGS WILL BE LABELED TO INDICATE A CERTIFIED
U-FACTOR OF .'75 4 50LAR HEAT GAIN COEFFICIENT OF .40 PER TITLE 24.
ALL GLAZING SHALL BE IN ACCORDANCE WITH 05G CHAPTER 24.
SIZE DOOR TYPE
{'' j�
50LID GORE EXTERIOR PAINT GRADE WOOD
`�...�./
DOOR. GLAZING TO BE TEMPERED W/ PANES.
2'-8" X V-6"
HOLLOW GORE PAINT GRADE WOOD
.i
2
DOOR.. FURNISHED 8 INSTALLED BY OWNER
(
21-6" X 6'-8"
HOLLOW GORE PAINT GRADE WOOD
�_--'
DOOR. FURNISHED 4 INSTALLED BY OWNER
(2)-2'-b" X V-8"
ALUMINUM SLIDING TEMPERED GLASS SLIDING MIRROR
DOORS. FURNISHED 4 INSTALLED BY OWNER
FLOOR PLAN NOTES:
i. PROVIDE NEW 120V (WITH BATTERY BACK UPWIRED ) SMOKE DETECTOR.
BATTERY OPERATED SMOKE DETECTORS PERMITTED IN EXISTING RESIDENCE.
2. LOCATE SMOKE DETECTORS IN BEDROOMS AND HALLWAY5 OR ADJACENT
ROOMS LEADING TO BEDROOMS. SMOKE DETECTORS TO BE HARD WIRED IN
NEW CONSTRUCTION Al BATTERY SACK -UP 4 AUDI5LE INA ALL SLEEPING
AREAS. MAY BE 50LELY BATTERY OPERATED IN EXISTING HOUSE.
5. 5HOWERMB DOORS SHALL BE TEMPERED.
4. NEW BEDROOMS EXCEPT BATHROOMS, KITCHENS AND LAUNDRY ROOMS
REQUIRE NATURAL VENTILATION BY MEANS OF EXTERIOR OPENABLE
WINDOWS OR 5K'fL.IGHT5 a MOTH THE FLOOR AREA OF THE ROOM, OR 10 S.F.
MIN. WHICHEVER 15 GREATER.
5. NEW BEDROOMS SHALL HAVE A MIN. 20" CLEAR WIDTH, 24" CLEAR HEIGHT AND
5.1 50. FT. MIN. OPENA5LE AREA FOR EGRESS. (GBC 510.4)
E,. PROVIDE WATER RESISTANT GYP. BACKING BOARD AS A BASE FOR TILE OR
WALL PANELS -I0" MIN. HGT ABOVE FIN. FLOOR FOR TUB OR 5HOWER.
ENCLOSURES OR WATER CLOSET COMPARTMENT WALLS. SEC. 2512
-1. PROVIDE SAFETY GLAZING IN FIXED OR OPERABLE PANELS ADJACENT TO A
DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING 15 AITHIN 24" ARC
OF EITHER VERTICAL. EDGE OF THE DOOR IN A OL05ED POSITION d WHERE THE
BOTTOM EXPOSED EDGE OF THE GLAZING 19 LE55 THAN 60" ABOVE THE
WALKING SURFACE.
g ALL PLUMBING FIXTURES TO BE SELECTED 4 INSTALLED BY OWNER.
al. NEW BATHROOM TO HAVE FLOURE5GENT LIGHTING.
10. ALL DIMENSIONS ARE TO FACE OF STUD UNLE55 NOTED OTHERWI5E.
11. ALL BRANCH CIRCUITS THAT SUPPLY 120 VOLT, SINGLE PHASE, 15-20 AMPERE
RECEPTACLE OUTLETS INSTALLED IN BEDROOMS SHALL BE PROTECTED BY
AN ARC. -FAULT INTERRUPTERS) PER SECTION 210-120 OF THE 2001 C.E.G.
12. TOILET5 SHALL USE NO MORE THAN 1.6 GALLONS PER FLUSH.
15. GLAZED WARDROBE DOOR5 5HALL MEET THE IMPACT TEST REQUIREMENTS OF
UBC 57D. 24-2. PART 2. LAMINATED GLASS MUST AL50 MEET THE 501 L TEST
REOUIREMENT5 OF U50 57D. 24-2 PART 2.
14. ALL NEW GLAZING SHALL COMPLY W/ 5TANDARD5 OF THE U.S. CONSUMER
PRODUCT SAFETY COMMISSION. MANUFACTURERS TO SUPPLY CERTIFICATE OF
COMPLIANCE TO THE OWNER.
APPLIC65I.E CODE5:
2001 CALIFORNIA BUILDING CODE (050)
2001 CALIFORNIA ELECTRICAL CODE (CEC)
2001 CALIFORNIA MECHANICAL CODE (CMG)
2001 C AL I FORN I A PLUMBING CODE (CPC)
ENERGY CODE (T24-6)
GLAZING INFORMATION:
GLAZING ALLOWED: 41-18 X 20% = qa SO. FT.
+ GLAZING REMOVED = a 50. FT.
TOTAL ALLOWED = 10550. FT.
TOTAL PROP05ED = 61 50. FT.
NEW 2X WOOD FRAME WALL5
EXISTING 2X4 WOOD FRAME WALLS
EXISTING 2X4 WOOD FRAME WALLS TO BE REMOVED
MEDICINE CAB.
EXHAUST FAN, 5
AIR CHANGE5/HOUR
MIN., TYP.
2x6 PLUMBING WALL
A"
SLOPE TO 5HOAER
FLOOR DRAIN
RECESSED MEDICINE
CABINET.
1/4" MIRROR, PROVIDE
6" COUNTER SPLASH.
PLUMBING PIPE VENT
THROUGH ROOF.
k
nt E FLOOR 4
SHOWER WALLS.
4 1 IWA AM71
r! 41mm'01*11ai k L
1/2• - 1'
0
EXISTING WOOD
PATIO TO REMAIN
UPGRADE EXISTING
ELECTRICAL METER
TO 200 AMP
SERVICE.
-.Ek5TING
• DRIVEWAY
EXISTING SIDEWALK
4701 FLIGHT AVE.
AREA TABULATION: TOTAL LOT AREA: _ -1,150 50. FT.
EXISTING SINGLE FAMILY RESIDENCE: = 1000 50. FT.
I GAR GARAGE: = 21050. FT.
EXISTING TOTAL AREA = 1,210 50. FT.
ADDITION AREA = 498 50. FT.
TOTAL ALLOWED: 50% LOT AREA (1150) = 5 575 50. FT.
TOTAL PROPOSED = 1,7105 50. FT.
i
Drawn by
Anibal Vargas
6271 Marshall Ave.
Buena Park, CA 90821
714.280.6170
47
I 2/25/05 - PLAN
GHEGK GOMMENT5
1
•
Uj
c
1*0
m
•
i
LL-
UL CID
•
.,m
+r■►
IF-
Cfj
ILL -
�■r
CC
•
cod
i_
LEGAL DESCRIPTION, N TR.
2969, ELK LOT 79 UN
A.P.N. a 108-351-06
NORTH
CABRERA ADDITION SHEET NO:
4701 W. FLIGHT AVE.
SANTA ANA, CA 92704
'' I I
A 114'ro m
rMum
NEW ALUMINUM SLIDING WINDOWS TO
MATCH EXI5TIN6, TYPICAL
j- NEW COMPOSITION SHINGLE ROOF,
OVER 1-50 LB. LAYER OF FELT.
NEW ROOF TO BE MINIMUM CLASS
"A" ICBO APPROVED ROOFING.
ROOF COLOR TO MATCH EXISTING.
i
I I FN61
F1
Zj
F1
r77-
L Ex151Ns NrzVi
EAST ELEVATION
I. VERIFY ALL CONDITIONS AND DIMENSIONS AT THE
JOB SITE BEFORE STARTING CONSTRUCTION
2. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR AND
SUB -CONTRACTORS TO SATISFY THEMSELVES AS TO THE
SITE CONDITIONS, DIMENSIONS, AND TO COMPLY WITH
ALL BUILDING CODES IN FORCE. COMMENCEMENT OF
WORK BY ANY SUBCONTRACTOR PRE5UME5
ACCEPTANCE OF PRIOR WORK, PLANS, 4 CONDITIONS
AFFECTING H15 FUNCTION. NO ALLOWANCE SHALL BE MADE
FOR ERRORS RE5ULTING FROM FAILURE TO IN5PECT
SITE, PLANS OR WORK IN PROGRESS.
5. ALL PLUMBING WORK SHALL BE DONE IN ACCORDANCE
Y41TH THE UNIFORM PLUMBING CODE
4. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE
WITH THE NATIONAL ELECTRICAL CODE
5. ALL LATHING, PLA57ERIN6, AND DRYWALL SHALL BE DONE
PER SECTION 2506 OF THE UNIFORM BUILDING CODE.
6. UNLESS NOTED OTHERWISE, ALL HORIZONTAL FRAMING
LUMBER SHALL BE NO. I DOUGLAS FIR, VERTICAL FRAMING
LUMBER SHALL BE NO. 2 DOUGLAS FIR. P05T5 SHALL BE
NO. I DOUGLAS FIR. CONNECTORS 5HOWN ARE TO BE
"51MP50N" OR APPROVED EQUAL.
'I. NOTCHING OF STUDS IN BEARING WALLS SHALL NOT
EXCEED 25% OF THE WIDTH.
8. NOTCHING OF STUDS IN NONBEARRING WALLS SHALL NOT
EXCEED 40% OF THE WIDTH.
a. BORED HOLES IN 5TUD5 IN BEARING WALL5 SHALL NOT
EXCEED 40% OF THE WIDTH.
10. BORED HOLES IN STUDS IN NONBEARIN6 WALL5 SHALL NOT
EXCEED 60% OF THE WIDTH, UNLESS THE 5TUD5 ARE
DOUBLED AND NO MORE THAN SUCH SUCCESSIVE DOUBLED
5TUD5 ARE 50 BORED.
11. BORED HOLES MAY NOT BE LOCATED OL05ER THAN 5/8"
TO THE EDGE OF THE STUD AND MAY NOT BE LOCATED
IN THE SAME AREA AS A CUT OR NOTCH.
12. ALL ROOF FASTENERS SHALL BE INSTALLED PER
MANUFACTURER'S INSTRUCTIONS.
15. WHERE TOP PLATES OR 50LE PLATES ARE CUT FOR PIPES,
A METAL TIE MIN..058" THICK 4 1 1/2" WIDE SHALL BE
FASTENED TO EACH PLATE ACROSS 4 TO EACH 51DE OF
THE OPENING WITH NOT LESS THAN 6-16d NAILS.
14. PROVIDE DOUBLE TOP PLATE W/ MIN. 48" LAP SPLICES.
SEC. 2520.11.2.
15. FIRE BLOCKING, VERTICAL OR HORIZONTAL,
SHALL CONFORM TO SEC. '706.2.
I&. STUCCO LATH SHALL BE FASTENED IN/ NO. 16 GA.
STAPLES WJ 1/8" LONG LEGS OR NO. If GA. NAILS,
1-1/2" LONG W/ "t/16" DIA. HEADS.
1-1. ROOFING MATERIAL WILL HAVE A MINIMUM
CLASS "A" FIRE RATING.
18. GALVANIZED SHEET METAL (28 &A. MIN) ROOF VALLEY
FLASHING 15 REQUIRED. (1508.5)
141. SPECIAL INSPECTIONS REQU I RED BY 100 RESEARCH REPORTS
SUCH AS FOR EPDXY.
20. PORTLAND CEMENT PLASTER (STUCCO), GYPSUM LATH AND
GYPSUM WALLBOARD SHEAR WALL5 SHALL COMPLY WITH
CBC SECTION 2515 AND TABLE 25-I.
21. PIPES, DUCTS AND OTHER NONSTRUCTURAL CONSTRUCTION
SHALL NOT INTERFERE WITH ACCE591BIL17Y TO OR WITHIN
UNDERFLOOR AREA. (2506.5).
22. ROOF DIAPHRAGM NAILING TO BE INSPECTED
BEFORE COVERING. FACE OF GRAIN OF PLYWOOD
SHALL BE PERPENDICULAR TO SUPPORTS.
25. RAFTER TIES SPACED 4' MAX. ON CENTER ARE
REQUIRED IMMEDIATELY ABOVE CEILING JOISTS WHICH
ARE NOT PARALLEL TO THE RAFTERS.
24. ROOF PURLIN5 MUST NOT BE SMALLER THAN THE
RAFTERS THEY SUPPORT. THE MAXIMUM SPAN FOR 2x4
/ 2x6 ROOF PURLIN5 15 4 FEET / 6 FEET. FOR THE
PURLIN SUPPORTS PROVIDE STRUTS NOT SMALLER
THAN 2x4 W/ AN UNBRACED LENGTH NOT MORE THAN 8
FEET 8 NOT FLATTER THAN 45 DEGREES FROM THE
HORIZONTAL TO BEARING WALLS. CBC 2520.12.-1
25. ALL ANCHOR BOLTS 4 HOLDOWN5 SHALL BE TIED IN
PLACE PRIOR TO FOUNDATIQN INSPECTION.
26. ALL W1 �
WOOD CONSTRUCTION SHALL COMPLY WITH CODE
SEC. 2520 & MIN. NAILING W/ CODE TABLE 25-II-8-1
ME
P,
SIMPSON MST24
METAL STRAP
EXI5TIN6 PLATE
TO NEW.
NORTH
I TO ROOF
x4HE
ALL NEW WINDOWS, WINDOW TRIM,
ROOFING MATERIAL 4 COLOR,
STUCCO FINISH #- COLOR TO BE
CONSISTENT THROUGHOUT EXISTING
RESIDENCE 4 ADDITION.
5
5 %}� TO ROOF
5/6" VIA. AB. a 24" O.G.
i\
i n..'
@ �I.
J
■i
•
'I
Ns-
A
►�
2x6 CEILING R I JOISTS a 16" D.G.
ri
v
x
0
-
5 �
I
:fl
X4
POST
6�C
3
Q
c)
x
:.i
cV
U
A
t Z44
i
2x
1--
0
STUCCO FINISH. TEXTURE AND
COLOR TO BE CON515TANT
THROUGHOUT EXISTING
RESIDENCE 4 ADDITION
t
1 0
'I► HV2A
4x4P.
� Q
2 X RIDGE
11 I
5 5 A HV2A
+ 52 44xx 4 P.
� I '4/
cv
TO x
4 x'12 #1 SM. POST
*-" - 'T
- M5TA15 STRAP, 14 A
ONLY
EXISTING ROOF RIDGE
GALVANIZED 1/4" CORROSION
RES15TANT ATTIC VENT, TYP.
WEST ELEVATION
SHEAR WALLS:
5/6" PLYWOOD, 5TD. SH 71`6 Wl 8d a 6" O.C. AT
EDGES AND 12" O.C. FIELD. 516" VIA. ANCHOR BOLTS
24" O.C.
"7/8" STUCCO OVER PAPERBACKED LATH,
16 GA. STAPLES a 6" O.C. EDGES 4 FIELD
ROOF SHEATHING:
15/52" THICK CD-X PLYWOOD
P.I. #24/0 MIN. UNBLOCKED
NAILING: 8d COMMON AT:
BN: 6" O.G.
EN: 6" O.C.
FN: 12" O.C.
FOOTING 50HEDULE:
CONTINUOUS FOOTING = 12" WIDE x 12"
DEEP IN/ 1- #4 TOP 4 BTM. U.N.O.
CONCRETE TO BE 2500 P51.
REBAR TO BE #4.
FOUNDATION NOTES:
I, USE 5/5" DIA. ANCHOR BOLTS EMBEDDED T' INTO CONCRETE.
2. USE PLATE WA5HER5 W/ A MIN. OF 2"x2"x5/16" THICK AT EACH
ANCHOR BOLT IN SHEAR WALL5.
5. CONCRETE FLOOR SLABS ON GRADE SHALL BE PLACED
ON A 4" FILL OF COARSE AGGREGATE OR ON A
MOISTURE BARRIER MEMBRANE. THE SLAB SHALL BE AT
LEAST 5-1/2" THICK AND SHALL BE REINFORCED WITH
WIRE MESH AT CENTER OF SLAB.
4. USE Ibd COMMON NAILS AT BOTTOM PLATE NAILING. SPACING
= (IO5x1.55x12)/(A0TUAL WALL SHEAR) IN INCHES.
5. PLYWOOD SHEAR PANELS SHALL BE MIN. GRADE CD W/
EXTERIOR GLUE. AND SHALL BE NAILED Al COMMON NAILS
AT ALL EDGES AS NOTED AND NAILED AT 12" O.C. AT
INTERMEDIATE FRAMING MEMBERS.
NEW COMP051TION SHINGLE ROOF, OVER 1-50
LB. LAYER OF FELT. NEW ROOF TO BE MINIMUM
CLA55 "A" ICBO APPROVED ROOFING. ROOF
COLOR TO MATCH EXISTING.
lal-5ii a1-1 l
5/5" DIAL. A.B. 24" O.G.
I1- fit
t?to RIFY LOCATION or -
PLUMBING 4 CONNECTIONS",. H02A ;
i TO EXISTING SEWER. 4 x 4 P. 5 TYP.
@1 a
HD2A N
5-1/2" THICK CONC. SLAB OVER 4 x 4 P.
2" MIN. SAND -FILL 4 10 MIL 9
V15QUEEN WI 6X6/IOXIO WIRE 5 TYP.
MESH * CENTER OF SLAB. POUR 4�_�
OVER EXIST. SLAB. 2 A
Bja
OLTS
d1 A
5 3
` ' HD2
4 P.
HV
4 x P.
5 5 5
Drawn bys
Anibal Vargas
6271 Marshall Ave.
Buena Park, CA 90621
714.260.6170
PROJECT N0. 04-06
DATE: 1/17/05
DRAWN BY: A.VARGAS
SCALE: AS NOTED
REVISIONS=
1 2/25/05 - PLAN
CHECK COMMENTS
SHEET TITLE -
FOUNDATION,
I=RAM I NCB PLAN5,
r-LEVATION5 4
NOTE5
Il■
a
i
�
..(owl
.s
r
�
SCALE, 1/4* - T-Ow
SCALE, 1/4• - T-O"
2x CONT. BLOCK'& rv/ LTP4
ROOF - O.C.
r — __ I �_ W_ . Ad day 12,
R-IcT BATT INSULATION, TYP. —
RIDGE PER FRAMING PLAN
12
J�4 MATCH EXISTING
DRILL 5/6" VIA. X 6" DEED' HOLE
f
1 •? n 6 �, ; AT EASTIN6 CONT. FOOTING
4 APPLY SIMP50N "SET' EPDXY
AFTER DOWEL 15 IN PLACE.
NEW SLAB TYP. #4 DOWEL AT 24" O.G.
� 7�e
ISTING FOUNDATION
SLAB TO EXISTING mr=TG
DRILL 5/6" VIA. X 6" DEEP HOLE
AT EXI5TIN6 CONT. FOOTING
4 APPLY 5IMP50N "SET' EPDXY
`-- NEW CALIFORNIA
T FRAMING, TYP.
NEW RAFTERS E.N. EXISTING PLYWOOD
PER PLAN
SHEATHING
SHEAR WALL
AFTER DOWEL 15 IN PLACE. NEW ROW OF CONT. x
TYP. #4 DOWEL AT 24 O.G. SHAPED BLOCKING
SIMPSON LTP4 E.N.
EXISTING FOUNDATION ANCHORS 0 16" O.G.
NEW FTG. TO EXISTING FTG.
SCALE, 1 1/2' - 1-0'
Im
4x P05T PER PLAN
SIMP50N HOLD DOWN
PER PLAN
2x P.T. SILL PLATE, TYP.
2x
PLYWOOD SHEAR PANEL ON EXI5TING 2x RAFTERS,
EXI5TING STUDS (WHERE NP'
OCCURS), TYP.
8 NEW ROOF AT EXISTING ROOF 4
SCALE 1 1/2' - 1'-0'
ROOF SHEATHING
2X4's AT 24" O.G. FLAT, TYP.-�
U E.N. U 4, NEW FOOTING _
'k-
° ° 2 X RAFTER5
2 X RAFTER5 4 ° 4. 24" Q.G.
24" O.G. SIMPSON LTP4
ANCHORS a+ 24" O.G. 4
DOUBLE 2X4 TOP ° ° 4
° .4
PLATES PLYWOOD SHEAR PANEL
(WHERE OCCURS), TYP. 4 DOUBLE 2X4 TOP
4 ° 4 PLATES
4 °
d . d
1/2" &YP. BD. 0/ 2 x 4
STU 5 AHr-F;M OCCURS.
VA
[*"A Us 4 !16
lmiAi •
N3
1:211
PER PLAN
INTERIOR FOOTING
C:C°Al G. i 1/09 .
2x 4 STUD WALL
(SEE PLAN)
OARS(ALL <8>
5EE P1�AN)
2X4 PRESSURE TREATED
D.F. SILL PLATE W/ 10"
ANCHOR BOLT (SEE PLAN
FOR SIZE 4 51FACI NG),
EMBEDDED 1" INTO
CONCRETE. USE 2 "x2 "x5/I6"
PLATE WASHERS.
WIRE MESH AT CENTER OF
CONC. SLAB, REFER TO
FOUNDATION PLAN
(1) #4 TOP AND BOTTOM
N t=A 2x4 5TUD5 a
51 MP50N
METAL E
NE1N IDOL
PLATES
EXISTING
2x4 5TUI
M5T-2
,TRAP tj
15LE 2X4 TO
16d
4"
�5
12
l
Z- _1� =a. , P_
A P
B.N.
< — 2x FASCIA BOARD
E.N.
SIMPSON LTP4
ANCHORS® 24" Q.G.
— PLYWOOD SHEAR PANEL
(WHERE OCCURS), TYP.
'SIMPSON" LSTA24 a 48" O.G.
BOUNDARY NAILING, TYP.
ASPHALT SHINGLES OVER
50 LB. LAYER OF FELT
2 X ROOF RAFTERS
® 24" O.G.
=,p..;=...ram• %
5IMP5qN A54 EACH
SIDE, 7yp.
j4x4AS SHOWN QN
G PLAN
N LTP4 EA. SIDEd x 1 1/2" EA. END
2 X CEILING JOISTS
PER FRAMING PLAN
NEW WALL TO EXISTING
6 TYPICAL RIDGE
2
EXTERIOR CEMENT PLASTER
0/ 50# BUILDING PAPER
0/ PLYAOOD SHEATHING
SCALE, 1 1/2' - 1-0'
SCALE- 1 1/2' - 1-0'
R-15 BATT INSULATION
2X4 STUD WALL, TYP.
2 X ROOF RAFTER5
12
PER PLAN
SHEAR PANEL WHERE
ROOF 5HEATHIN6 AT CALIFORNIAASPHALT
SHINGLES OVER 30 LB.
OCCURS, TYP.
FRAMING
' `�
LAYER OF FELT, TYP.
2X4 PRESSURE TREATED D.F.
SILL PLATE IN/ 10" ANCHOR
80LT (SEE PLAN FOR SIZE
2 X CONT. A/ 2-I6d @ 24" O.G.
2" DIA. VENT MOLES - 2 PER
SPACING), EMBEDDED "1" INTO
NAIL. TO RAFTER. TYR.
BLOCK a EVERY RAFTER BAY
CONCRETE. USE 2 "x2 "x5/16"
B'N'
f .
PLATE WA5HER5.
5-16 .TWEEN &LNG.
STUCCO SCREED
! 1
J5T5. 4
TYP.
NATURAL AND/OR FINISH GRADE
GATT lWc41LATION
-- 2X CEILING J
5 a
OPTIONAL CONSTRUCTION
JOINT
12" DEEP X 12" WIDE FOOTING
A/ #4 REBAR a TOP 4 BOTTOM
A TYPICAL EXTE RIOR FOOTING 9 CALIFORNIA
i +
19K(ToMrs
TYP.
A35 ® 24" O.G.
2 X DOUBLE TOP -.
PLATE, TYP.
R-13 BATT INSULATION
1/2" GYP. 50. O/ 2 x 4
WOOD STUDS a 16' O.C.
TYPICAL SAVE
SCALE 1 1/2' - 1-0'
161, O.C. (PER N)
- 2 X CONT. BLOCKING,
T`r'P.
- EXTERIOR CEMENT PLASTER
0/ 2 LAYERS GRADE "0" PAPER
0/ PLYW000 SHEATHING
- SHEAR WALL WHERE
OCCURS
Drawn by,
Anibal Vargas
8271 Marshall Ave.
Buena Park, CA 90621
714.260.6170
PROJECT NO. 04-06
,DATE 1/17/05
DRAWN BY: A.VARGAS
SCALE AS NOTED
REVISIONS-
1 2/25/05 - PLAN
CHECK COMMENTS
SHEET TITLE
DETAILS, NOTES
8 Gf2055
SECTION
..
•
•
4M
.s
�r
r�r
�
•
•
F
L
Mandatory Measures Checklist: Residential (Page 1 of 2) MF-lR
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk W may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shalt be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable,
DESIGNER
ENFORCEMENT
Building Envelope Measures
150(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturer's labeled R-Value.
X 150(c); Minimum R-13 wall insulation in wood framed walls or equivalent U-value in metal frame walls (does
not apply to exterior mass watts).
Elx 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent.
150(l): Stab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
FV__1 118; Insulation specified or installed meets insulation quality standards. Indicate type and form.
I A I
121 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfittration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have (abet with certified U-Factor, certified Solar Heat Gain
Coefficient (SHGQ and infiltration certification.
3. Exterior doors and windows weatherstripped, all joints and penetrations caulked and seated.
E] 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
11 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
El150(e)-.
Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory-buitt fireplaces have,
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
110-13; HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
1500): Setback thermostat on all applicable heating and/or cooling systems.
r_v_1 150(j): Pipe and Tank Insulation
LA
J
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
,EnergyPro 3.1 By EnergySoft User Number- 2299 Job Number: 050228 Page: 5 of 14
Mandatory Measures Checklist: Residential (Page 2 of 2) MF-1R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk W may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
Lry- I . 150(m): Ducts and Fans
1. All ducts and plenums installed, seated and insulated to meet the requirements of the 1998 [ME Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be seated with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, ULISIA, or UL161B. If mastic or tape is used to seat openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shalt not be
seated with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than seated sheet metal, duct board or flexible duct shalt not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross -sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be seated With cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shalt be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
114, Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between fitter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between fitter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
0 115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot - 150 Btu/hr)
118 (f): Coot Roof material meet specified criteria
Lighting Measures
F] 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shalt be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
FX1150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 tumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 1501102.; and recessed ceiling fixtures are IC (insulation cover) approved,
1 3.1 By EnergySoft User Number: 2299 Job Number: 050228 Page: 6 of �14
Certificate of Compliance:
Residential
(Part 1 of 2) CF-1R
CABRERA RESIDENCE ADDITION
2/23/2005
Project Title
Date
4701 Haht Avenue Santa Ana
Project Address
Building Permit #
ANIBAL VARGAS
(714) 260-6170
Plan Check / Date
Documentation Author
Telephone
Computer Performance
8
Field Check / Date
Compliance Method (Package or Computer)
Climate Zone
Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 1 .498-f? Average Ceiling
Height: IQ ff
Total Conditioned Stab Area: 1 498 f?
Building Type:
(check one or more)
FX1 Single Family Detached
❑Addition
F] Single Family Attached
Existing Building
El Mutti-Family
FV_01
L/-\j
Existing Plus Addition
Front OrientationSouth) 180 deg- Floor Construction Type: Stab Floor
Number of Dwelling Units: i _Qk
Number of Stories: - 1 ❑ Raised Floor
Const.
Coonen mpt
Frame
Assembly
Location/Comments
a
TvDe
U-Vatue
(attic, garage, typical, etc.)
Stab On Grade
A/a
0.756
Covgred Stab w/R-0.0 Perimeter Insulation
Default Wall Prior to 1978
W ood
0.385
Exterior Wait
Default Roof 1978 to Present
W ood
0,047
Exterior Roof
R-13 Walt (W.13.2x4,16)
W ood
0.088
Exterior Watt
1-30 Roof JR.30.2x6.161
W ood
0.035
Exterior Roof
I LVILl I MM I IVII
)HdUt11k4
UtVlLttJ
Type
Orientation
Area
Fenestration
Exterior
Overhang
Side Fins
(SF)
U-Factor
SHG
Shadinci
Yes / No
Yes / Nc
Front
(South)
5 0
1.28
0.83
BuaSGreen
El 2
1:1 El
Left
()lest)
28.5
1.28
%83
Bug Screen
El Q
1:1 0
Rgar
(NgEth)
16.0
1.29
0.83
Bug Screen
R RX
Left
(West
3.0
0,87
0.70
Bug Screen
X1
El F
El El
❑
Rear
(North)
19.0
0.87
0.70
Bug Screen
El rX1
1:1 10
Right
(East)
BQ.Q
H5
_xm_
Bug-, GrPen
El FX I
F1 El
11 11
El El
R 1:1
El 0
F1 F1
D El
El 1:1
0 El
11 1:1
R R
❑
11 11
11 El
=01 Im. : (Part 2 of 2) CF-1R
CABRERA RESIDENCE ADDITION 2/23/2005
Project Title Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load,
Distribution
Heatiw Equipment Minimum Type and Duct or
Type ( urnace, heat Efficiency Location Pipin Thermostat Location
I
pump , etc.) (AFUE/HSPF) (ducts, attic, etc.) R-Value Type Comments
Fan Type W;;1I_EUCaacZ_ 60% AFUE QtjrtIP-,4z / with FaD __J1La__ k Exis�vqfpm
ni-ral Eurnaca 65% AEUE Ductlpsq / with F;in D/a Nn 1CLath;irk NeW Fnrnare
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location
heat pump, evap, cooling) (SEER) (attic, etc.) R-Value Type Comments
No Cootina _11&_sffs_ ntirtips_q DLaNn Cathnrk Exisiinn_',",v�+Aln
No 1Q12IiOQ In A EFF2 DtlfflesS Za No Sp+hArIg Now Ftirnnra
WATER HEATING SYSTEMS Rated Tank Energy Fact.' PC External
Water Heater Water Heater Distribution # in Input Cap. Or _ ovary Standby Tank Insul
System Name Type Type Syst. Btu/hr (gat) Efficiency Loss W R-Value
I For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts I and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct seating and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Documentation Author
Name:
Name:
Title/Firm: MR & MRS. CABRERA
Title/Firm: ANIBAL VARGAS
AddresS: 4701 Flight Avenue
Address. 6271 Marshall Avenue
Santa Ana. (A
Buena Park, CA 90621
Telephone- (714) 418-1896
Telephone: (714) 260-6170
Lic. #:
(s- e) (date)
(signature) (date)
Enforcement Agency
Name: Efrain Olivas
Title/Firm. ADVANCED TITLE 24
Address: 1235 N Harbor Blvd, Suite 235, Fullerton
Telephone: (714) 525-9824
(siqna re/staMD) (date)
IEnerqyPro 3.1 By EnergySoft User Number. 2299 J-66 Number: 050228 Paue; 4 of 14 1
Drawn by.
Anibal Vargas
6271 Marshall Ave.
Buena Park, CA 90621
714.260.6170
PROJECT NO. 04-06
DATE: 1/17/05
DRAWN BY: A.VARGAS
SCALE. AS NOTED
goo
I - I
SHEET TITLE:
LLJ
<
CO
0 co
Co
CD <
U 00
<
<
C) <
r-_
-.;4-
V)
IN