Loading...
HomeMy WebLinkAbout10148520.pdf1 tl - esa '` 4,1, 1 .- (, 11 1 11 '2 -Z N lP �m r r U`a Air« 8 i✓1{l�i�� 0�� � 4S i' /a i\.(1 4E 5zo d STRUCTURAL MATERIAL NOTES CONCRETE LUMBER 1. ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR 1• ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FiR CONFORMING WEIGHT HARD ROCK TYPE (150 •/CU. FT.). AGGREGATES SHALL TO DIVISION 23 (2001 C.B.C.) BE NATURAL SAND AND ROCK CONFORMING TO ASTM C-33 WiTH PROVEN 2. RAFTER, BEAMS, PURLINS SHALL BE DOUGLAS FiR NO, UNLESS SHRINKAGE CHARACTERISTICS OF LESS THAN 0.05 `/, OTHERWISE NOTED 2. READY MiX CONCRETE SHALL BE MiXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94. PLACEMENT OF CONCRETE SHALL CONFORM TO 3. JOIST, PURLINS 2" TO 4" WiDE, 6" 1& DEEPER N01E ACi 301, BEAMS, PURLINS OVER 4" WIDE NOA 3. CEMENT FOR ALL CONCRETE SHALL BE PORTLAND CEMENT TYPE V, SUSPURLINS 2" TO 4" WiDE. 6" 0 DEEPER NNOA OR 11 LOW ALKALL CONFORMING. TO ASTM C-150. LEDGERS NO.2 STUDS 2" x 4" OR 3" x 4" STUDS 4, MINIMUM COMPRESSIVE STRENGTH OF CONCRETE AT AGE OF STUDS 2" x W NO1 28 DAYS FOR: POSTS 5" x 5" AND LARGER NNOA SILLS, PLATES AND BLOCKING NO,2 FOOTINGS 2500 Poi SLAB ON GRA DE 4, SILLS AND PLATES IS CONTACT WITH CONCRETE OR MASONRY AND �,PSI WITHIN 48" OF GROUND SHALL BE PRESSURE TRESTED DOUGLAS FIR SIDE WALKS RO000 POD P51 (PTOF), SILLS SHALL BE BOLTED TO THE FOUNDATION WITH 5/8" S. MAXIMUM SLUMP SHALL NOT EXCEED 4" DIAMETER x 10" BOLTS AT 48" ON CENTER, 121" MINIMUM FROM 6. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A ENDS OR 2 BOLTS MINIMUM PER PIECE. UNLESS NOTED OTHERWISE, MINIMUM OF 5 DAYS AFTER PLACEMENT, ALTERNATIVE METHODS S. STUD WALLS ABUTTING A CONCRETE OR MASONRY WALL SHALL BE WILL BE APPROVED IF SATISFACTORY PERFORMANCE CAN BE BOLTED TO THE WALL WITH 5/8" ANCHOR BOLTS AT 24" ON CENTER. ASSURED. 6. ALL NQN BEARING STUD WALLS SHALL BE 2 x STUDS AT 16 O.C. 7, ALL REINFORCING STEEL. ANCHOR BOLTS, DOWELS AND OTHER WITH Jd" GYP, BOARD EACH SIDE. UNLESS OTHERWISE NOTED. INSERTS SHALL BE SECURELY FASTENED IN THE FORMS BEFORE 7 ALL STUD WALLS SHALL HAVE FULL HEIGHT 1x 6 DIAGONAL CONCRETE iS POURED. ADEOUATE CLEANOUTS SHALL BE PROVIDED LET -IN BRACES AT ENDS A INTERVALS NOT EXCEEDING 25 FT, IN BOTTOM OF CONCRETE FORMS FOR PROPER CLEANOUT AND INSPECTION. D.C. UNLESS OTHERWISE NOTED ON PLANS. BRACES SHALL COVER A MINIMUM OF SIX STUD SPACES. S. VIBRATION OF CONCRETE SHALL BE IN ACCORDANCE WITH THE S. COMMON NAILS SHALL B€ USED. GENERAL PROVISIONS OUTLINED IN PORTLAND CEMENT ASSOCIATION SPECIFICATIONS ST-26. 9. FIRE BLOCKING 2 x i 1/2" THICK, SHALL BE PLACED IN STUD 9. EXPOSED CORNERS OF COLUMNS. BEAM, WALL, ETC. SHALL WALLS AT CEILING AND FLOOR LEVELS, AT EACH 10-HEIGHT OF BE FORMED WITH N" CHAMFERS UNLESS DETAILED OTHERWISE. STUDS.AND BETWEEN STAIR STRINGERS AT SUPPORTS. 10. CONCRETE CONTRACTOR SHALL SUBMIT PROPOSED CONCRETE 10. JOISTS SHALL BE BLOCKED AT SUPPORTS AND BRIDGED OR BLOCKED DESIGN MiX TO THE ARCHITECT AND ENGINEER OF RECORO, PRIOR T4 AT INTERVALS OF 8' WHERE JOISTS ARE 2 x 12 OR DEEPER. STARTING THE WORK. 11. MAXIMUM UNSUPPORTED HEIGHT FOR NON -BEARING PARTITION SHALL 11. NO WATER SHALL BE ADDED TO CONCRETE WITH TEMPERATURE BE Z it 4 0 16" D.C. UP TO 14'-0" IN EXCESS OF 954F, 2 it 6 0 16" O.C, UP TO 201-0" 12. WIRE MESH LAP (END 6 SIDE) SHALL BE ONE FULL MESH -2. 2 x 8 0 16" O.C. UP TO 26'-0" 12, PROVIDE DOUBLE JOISTS UNDER PARALLEL BEARING PARTITION WALLS, 13. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM '%2" AND A MAXIMUM jb" LARGER THAN THE BOLT DIAMETER. ! It ,53-ca f- a gg CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page I of 3) CF-1R Project Title � pat E r ulcc t uuress p a� Building Permit # IM ff`� ty Plan Cheek/Daze Documentation Author Teleph ne `" �- Field Check/Date Co pliance Method (Package or Computer) Climate Zone Enforcement Agency Use only GENERAL INFORMATION o Total Conditioned Floor Area 14 0-7 ft2 Average Ceiling Height: 9)ft Conditioned Slab Floor Area c�o ft2 Building Type: JQ Single Family Addition (check one or more) Multi -Family Existing -Plus -Addition e Front Orientation; : 0 North / South / Eas es 11 Orientations (input front orientation in egrees from True North and circle one) Number of Stories , j Number of Dwelling Units: Floor Construction Type: Slab ed Floor ' cie one or both) RADIANT BARRIER (required in climate zones 2 4 8-15) Required for this submittal yes _no BUILDING ENVELOPE INSULATION Component Type r ulcc t uuress p a� Building Permit # IM ff`� ty Plan Cheek/Daze Documentation Author Teleph ne `" �- Field Check/Date Co pliance Method (Package or Computer) Climate Zone Enforcement Agency Use only GENERAL INFORMATION o Total Conditioned Floor Area 14 0-7 ft2 Average Ceiling Height: 9)ft Conditioned Slab Floor Area c�o ft2 Building Type: JQ Single Family Addition (check one or more) Multi -Family Existing -Plus -Addition e Front Orientation; : 0 North / South / Eas es 11 Orientations (input front orientation in egrees from True North and circle one) Number of Stories , j Number of Dwelling Units: Floor Construction Type: Slab ed Floor ' cie one or both) RADIANT BARRIER (required in climate zones 2 4 8-15) Required for this submittal yes _no BUILDING ENVELOPE INSULATION Component Type Frame Type wd = wood Sit = steel Cavity Insulation R-Value Sheathing Insulation R-Value Total R- Value' Assembly U-Factor' Location/Comments (attic, garage, typical, etc.) Wall 1X Wall Roof eZ X (x , Roof Floor c� Floor Slab Ede - .- •^- ..d , -. .... �.- tiSLOG r i"" ,-tN,7 , ..,�� gw�' pmre; �� •..,. <) Egad � G F�t.A u i £ `4'., t mom __ __ �.. - c.�• � 1. -Z 4 � i 'I a "� a Z Qj � .S� � •-�- _- MICROFILM N AIA`I` I .� mptiance Forms lE August 2001 A-2 �1( 1rl IS KD h . .". CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 3 of 3) CF-1R 12 yy j 1 Projebt Title °b 9T. 6ERTFYD£ PiAC£ g A b . ! 'Zl COMPLIANCE STATEMENT ao' b 4 Po• +sue � o --^-.-_ 0k, P 0� / ss•. q 0 -yy.• 4 4 Q o*. 9` rt0* u �I i} i2 > J3 f3 a rRX 0 (i)010 0T 4 3 P I t� 246 26 10 P K1 ig � I1 20 i2 I P 21 i3 rs /3 la r> 4 23 J 13 i 24 14 , �9 T� t5 0 !s 26 PI M 17 25 Po J1 16 27 1 A i0 !Sr Lj '2 tb'r5 o�a►a4 a � ti�ifV� I It, Str 'tr' trd• a t0 25 26 (i) lYl ff isar 2/ Z5 a \?l s 15 4 � � LJ i6 i 7� IT 22.9 I8 Q a I9 PO t0 /J 20 fi 19 JP 21 12 1813 @ 13 rTt4 t1 S 14 /9 24 m ter..,. ..,...-. - a This certificate f compliance � ��--- o lists the building features and performance specifications needed to comply with j 1 Title 24 Parts I and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built, in multiple orientations, any shading feature that t =roo ", "is varied is indicated in the Special Features/Remarks section, The undersigned recognize that compliance using duct sealing and TXVs requires installer testing and certification and field verification by an approved HERS al Designer or Owner (per Business and Professions Code) Documentation Author Name: Name: 4'Title/Firm: e( L)S,-� Title/Firm: '� t, �C r� y n �Address: �r�, - #- = Address: �t 1.... CAN Telephone: Oldp (:I I ii 2--� TeleP ek --- r_tc �,k - 64. if, -z- 2-C, 4- °u ANARURST `° iy� GLACE u Lie. : tr, TRACT No.597 M.M. 49-7 iQ NOTE- ASSESSOR'S BLOCK 8 ASSESSORS MAP` P#RCEL NVMVM5 BOOK r5 FAi5E 11 $HOW -'^. f {':' " z 2 (date) MARCH 194E IN CIRCLES COUNTY OF ORANBE t\ j _✓) '' C"11 *� rI�111✓ l // Enforce ent Agency Liv4& A).CC roe .w&d,.AI - FZo/G 111/ Title: fc, N1 YWOOD ARCHMNRAL e : A . CA40 I. PLYWOOD SHEETS SHALL BE COX CONFORMING TO PS 1-95 ANDACCEPTED FOR e: IN SHALL BE STAMPED WITH THE DRPA GRADE OF THE AMERiCAN PLYWOOD ASSOCIATION, UNLESS NOTED OTHERWISE ON THE PLANS. REINFORCING STEEL s 2. EACH SHEET SHALL HAVE A MINIMUM AREA Of 8 50, FT, WITH AREQUIREMINIMUM 1. REINFORCING stamp) DIMENSION OF 2 FEET. 3, SEE FRAMING PLAN (date) STEEL SHALL BE INTERMEDIATE GRADE DEFORM€ a PLCafians BARS AS FOLLOWS :ili5 FOR DIAPHRAGM NAILING SCHEDULE. NAILING SHALL BE INSPECTED AND APPROVED BEFORE COVERING, FOOTING, SLAB ON GRADE, MASONRY, S 0 S B rld S ifi� EftMANS AND BENT DOWELS, TIES 43 BAR AND SMALLER ASTM A-615 GRADE 40 64 BAR ANDLARGER at Ii ii S DiWii 0RSO 9iiGP Ion O Same lid ASTM A-615 GRADE 60 2. DEFORMATION OF REINFORCING SHALL BE iN ACCORDANCE S Permission i i N 0$ Santa Ans F O U N D AT I (N NOTE WIT ASTM A-305 AND BENDING IN ACCORDANCE WITH AC1318-95. The 3, MINIMUM CONCRETE COVER OVER REINFORCING REBAR FOR : I CCB GCB Of iS Pig" Ind S Cb i iOOS (EXCEPT AS NOTED OTHERWISE) 10 10,It nor be l Y URES 1. FOUNDATION HAS BEEN DESIGNED ASSUMING MINIMUM ALLOWABLE NOT EXPOSED TO WEATHER OR EARTH p• of the I I CHECKLIST: RESIDENTIAL (Page I oft MF-1R 1 Provi .i $ Of ANY G'Ity I gnC@ Of SOIL BEARING PRESSURE PER 1997 UNIFORM BUILDING CODE SHALL BE AS FOLLOWS[ EXPOSED TO WEATHER i t j2. EXPOSED TO EARTH PiLASTER, 2t" W Not : L se sid ildih s subject to the Standards must contain these measures regardless of the compliance approach used. --1 d th an asterisk (") may be superseded by CONTINUOUS FOOLING + 1000 p,S,F. BEAM 6 COLUMN TIES !2 , FORMED FOOTING AND WALL EXPOSED 7O EARTH _ . more stringent compliance requirements listed on the Certificate of - - Co 1 ce. hen this checklist is incorporated into the documents, the features noted shall be considered all as gi ISOLATED FOOTING - 1000 P.S.F. 2•• UNFORMED FOOTING AND WALL EXPOSED TO EARTH 3" parties mandatory component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on thij checklist only. the SLAB ON GRADE 2., i 2. ALL FOOTINGS SHALL BE FOUNDED ON OR BELOW FiRM UNDISTURBED NATURAL SOiL, OR APPROVED COMPACTED Fu I On 4. SPLICE IN CONCRETE t MINIMUM OF 36 BAR rA­ tructions: Check or initial applicable boxes when completed or enter N/A if not applicable ADJACENT FINISH GRADE UNLESS NOTED OTHERWISE. DIAMETER OR 12 WHICHEVER IS GREATEN tG i . 3. ALL FOOTING SHALL BE CENTERED ON PILASTER AND/OR WALL AND 5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 AND 1-82. COLUMN UNLESS OTHERWISE NOTED, 4, FINISH FLOOR (i ,f,) EXCAVATION SHALL BE AS NOTED ON GRADING 6 ALL ADETA8M98 OF REIWORCING SHALL CONFORM TO THE REOLIREMENT�ollowi C Apr PLANS. F 5• THE CONTRACTOR SHALL SOLELY RESPONSt� E FOR ALL EXCAVATION 7. ALL REINFORCING STEEL, DOWELS, ANCHOR BOLTS, INSERTS, ETC, SHALL BE SECURED IN PLACE PRIOR TO PLACING ANY CONCRETE PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ANY OR GROUT.Planning ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES IN S. ALL REINFORCING STEEL SHALL CONFORM TO THE REOLIREMENTS ACCORDANCE WITH ALL NATIONAL,STATE AND LOCAL SAFETY OF ASTM A-615 GRADE 60. ORDINANCES, 9. ALL REINFORCING BAR BENDS SHALL BE MADE COLO. 0 Fire Department 6. ALL FOOTINGS SHALL BE FORMED TO MEET SIZES INDICATED ON 10. ALL REINFORCING BARS SHALL BE FREE FROM GREASE, RUST, MiLL DRAWINGS. DETAILS, AND/OR SCHEDULES, SCALE OR ANY OTHER FOREIGN MATERIAL WHICH MAY AFFECT TH, 7, ALL FOOTINS AND PIERS SHALL BE CENTERED UNDER THE BUILDING BARS ABILITY TO BOND TO THE MORTAR. Police Department COLUMNS. (U,N.O.) It. REINFORCEMENT THAT IS PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT AS SPECIFICALLY DETAILED iN THI S S. ALL EXISTING UTILITIES THAT INTERFERE WITH THE STRUCTURAL FOUNDATIONS DRAWINGS OR WITHOUT THE WRITTEN APPROVAL OF THE ENWER OF RECORD.Public Works Aq %,o SHALL BE REMOVED AND RELOCATED. 9, ALL PIPES, DUCTS AND CONDUITS WITHIN THE SPHERE OF INFLUENCE OF ON THE DRAWINGS. H 12. ALL REINFORCING STEEL SHALL BE PROYNDED AT ALL POUR JOINTS THE FOOTING, (THE PRESSURE ZONE, EXTENDING BELOW THE FOOTING,, €RE LAP AND/OR SPLICE LOCATIONS ARE BASED ON A 2 HORIZONTAL TO 1 VERTICAL SLOPE), SHALL BE SLEEVED NOT SPECIFICALLY INDICATED, PROVIDE CLASS G SPLICE PER 'a t THROUGH CONCRETE CAST-iN-PLACE AT THE FOUNDATION POUR. SHOEDDREWING SPLICE LOCATIONS SHALL BE CLEARLY SHOWN RON E 10, FOUNDATION MAY BE SUBJECT TO STRUCTURAL REVISION IN THE HELD SHOP DRAWINGS AND APPROVED BY ENGINEER OF RECORD BEFORE FABRICATION. t DUE TO POSSIBLE VARYING SUBSURFACE CONDITIONS. 13. PLACING TOLERANCES AND BAR SUPPORTS SHALL CONFORM TO THECounty i 9 Fl �. s ca t MANUAL OF STANDARD PRACTICE FOR REINFORCING CONCRETE CONSTRUCTION, BY WCRSI. 14. CLEARANCE BETWEEN PARALLEL BARS IN A LAYER SHR I BAR DIA., NORALL NOT BE FOUNDATION PLATES/ SILLS BARS IN SECOND LESS THAN V, OLAYER SHALL BE DIRECTLY ABOVE BARSSINEFIRST 1, FOUNDATION PLATES OR SILLS SHALL BE BOLTED TO THE FOUNDATION LAYER. MIN, DISTANCE BETWEEN LAYERS • t". OR FOUNDATION WALL WiT14 NOT LESS THAN V DiA. STEEL BOLTS EMBEDDED AT LEAST 7" INTO THE CONCRETE OR MASONRY AND SPACED NOT MORE THAN W-0" APRART, THERE SHALL BE A MINIMUM OF (2) BOLTS PER PIECE WITH ONE BOLT LOCATED WITH 12" OF EACH END OF EACH PIECE A PROPERLY S12E0 SHALL BE TIGHTENED ON EACH BOLT TO THE PLATE. OUNDATION PLATES AND SILL SHALL BE THE KiND OF WOOD SPECIFIED IN SECTION 2306A OF THE 2001C.B.C. ES RIPTI N DESIGNER ENFORCEMENT Envelope Measures: + §150(a): Minimum R-19ceiling insulation.j - r §150(b): Loose fill insulation manufacturer's labeled R-Value. * 050 0 Minimum R-13 wall insulation in wood framed wails arequivalent U-Factor in metal frame walls does not a I to exterior mass watts . * 4150(d): Minimum R-13 raised floor insulation in framed floors. _ §150(1) : Slab edge insulation - water absorption rate no greater than 0,30%, water vapor transmission rate no neater than 2,0 permilinch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls I. designed Doors and windows between conditioned and unconditioned spaces to limit air leakage, a age. 2. Fenestration products (except field -fabricated) have label with certified U-Factor, certified Solar Heat Crain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f) Special infiltration barrier installed to comply with § I51 meets Commission quality standards. e)I 1tt5laliaiidn.of Fitplaces, Decorative Gas Appliances and Gas Logs. i. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control a Flue damper and control 2. No continuous burning gas pilot lights allowed. CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 2 0 CF-IR Projett Title Dafe HVAC SYSTEMS Note: Input hydronic or combined hydronic data under Water Heating Systems, except Design Heating Load, Distribution Heating Equipment Minimum Type and Duct or Heat Pump Type (furnace, heat Efficiency Location Piping Thermostat Configuration pump, etc. AFUEorHSPF ducts attic etc. R-Value T s litor ack e Coaling Equipment Minimum Duct Heat Pump Type (air conditioner, Efficiency Location Duct Thermostat Configuration heat pump, eve .coolIn SEER attic etc. R-Value TvDe (split or package) SEALED DUCTS and TXVs (or Alternative Measures 0 Sealed Ducts (all climate zones) (installer testing and certification and HERS rater field verification required) 11 TXVs, readily accessible (climate zones 2 and 8-15 only) (Installer testing and certification and HERS Rarer or field verification required) 0 Refrigerant Charge/Air Flow (climate zones 2 and 8-15 only) (installer testing and certification and HERS Rater or field verification required) OR Alternative to Sealed Ducts and TXVs (see Package C or D Alternative Package Features for Project Climate zone) Climate Zone Window SHGC Window U-Factor SEER Heating WATER HEATING SYSTEMS Energy' External Rated' Tank Factor or Tank Water Heater Distribution Number Input (kw Capacity Recovery Standby' Insulation Tvne i in S stem or stuJhr 11onsI Efficien Loss °la R-Value i. For small gas storage water heaters (rated inputs of less than or equal to 75,000 Bm/hr), electric resistance, and heat pump water heaters, list Energy Factor. For large gas storage water heaters (rated input of greater than 75,000 Bm/hr), list Rated input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list rated input and recovery efficiencies. SPECIAL FEATURES (add extra sheets ifne ssarr 1, Package C and D. TXVs, Sealed Ducts; Radiant Barriers (see installation requirements for radiant barriers in Section 8.13 of the 240 i Residential Manual). Package C: thermal mass (thermal mass type, coverittg, thickness, and description}, tt b I� � a� q � Compliance Forms August 2001 . A-3 MANDATORY MEASURES CHECKLIST: RESIDENTIAL Pa e 2 of 21 MF-1R Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (+) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. Compliance Forms August 2001 A-6 Space Conditioning, Water Heating and Plumbing System Measures: § 110.§ 113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on an applicable heating and/or cooling systems. 15 § 0(1): Pipe and tank insulation L Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55* F insulated. 6. Piping insulated between heating source and indirect hot water tank. Compliance Forms August 2OQ1 A-5 w� o a _ MI M eq '- Ig 3 rj a :3 Ora n��n lt"J�U I✓'1 V Go C E Q v U m (� eo to c m A `n x �.�/ 0 O L✓ u "C a? xrw 4/-- / - off- f T, g �55 a15 5 an ;4aT" 'lls ffi�? , i % { isIs t. yc"3�� !. y ,Ca O bM 4-1 L }.. , ' f i� 3. to N Date Scale Drawn Job Sheet Alm wasupoo Of Streets _ 24 X 36 PRINTED ON NO.1000" CLEARPRINT* Wall covering shall be cement plaster, the or, approved equal to 70 inches above drain at showers or tub with showers. Materials other than structural elements shall be moisture resistant. Glass enclosure doors and panels must be labeled Category II. Swing door outward. Net area of shower receptor shall be not less than 1,024 sq. in. of floor area, and encompass 30 inch diameter circle. (807.1.3, 2406, 2407, and PC412.0) ?,r,6Q e--' hard -wired smoke detector with a battery back up in each sleeping room and at a point centrally located in the corridor or area giving access to each sleeping area: a detector shall be located at each story and basement, on the upper level of split level stories and both levels if sleeping area is on lower level; a detector shall be located in close proximity to the stairway when sleeping rooms are on the upper level. Where the ceiling height of a room open to the hallway serving the bedrooms exceeds that of the hallway by 24 inches or more, detectors shall be installed in the hallway and near the high point of the adjoining room. (Battery operated smoke detector permitted in existing construction only). (310.9.1) QGlazed wardrobe door's shall meet the Impact Test Requirements of UBC Std. 24-2, Part 11. Laminated glass must also meet the Boil Test Requirements of UBC Std. 24-2, Part 11. Fire blocks and draft stops in combustible construction in accordance with CBC Section 708. Show location(s) and provide typical construction details, �g6 -51k5f--f -,5v-t Provide fire blocking in concealed spaces of stud walls and partitions, including furred spaces at the ceiling and floor level and at 10 ft. intervals both vertical and horizontal. (708.2) 04 0 0 r-ri Li IA The City has encountered a large number of inspection problems arising from a lack of specific framing details. The following listed items are required to be shown on the plans (106.3): a. All plumbing walls are to be framed with a minimum of 6" studs. b. Double walls used as plumbing walls are to be a minimum of 8" wide and no "flat' studs permitted. Staggered studs are acceptable. c. Permissible notching and boring of joists are to be shown on the plans and shall not exceed CBC Section 2320.8.3 allowances. d. Notching of exterior and bearing/nonbearing walls shall not exceed 25%/40% respectively. Bored holes in bearing/nonbearing walls shall not exceed 400/o/60% respectively. In no case shall the edge of the bored hole be nearer than 5/8 inch to the edge of the stud. (2320.11.9 and 2320.11.10) e. Header and trimmer details for doors and windows are to be shown with full length trimmers, specifying the size of the header and trimmer. (2320.11.6) f. All framed buildings which are required to be designed by an engineer or architect must be signed prior to submission into plan check MECHANICAUPLUMBING The following are required for fumace or comfort cooling equipment in an attic: a. Scuffle 22" x 30" or the size of the largest piece of equipment and located not over 20 feet from equipment is required. (MC 307) b. Unobstructed passageway 24 inches wide of solid continuous flooring from scuffle to equipment and its controls. (MC 307.3) c. Unobstructed work space of 30" min. depth in front of equipment. (MC 307) d. Light over equipment With switch at scuffle. (MC 306) e. Vent through roof a min. of 5 feet above the highest vent collar which it serves. (MC 806.2) f. Fumace installation shall meet all listed clearance. Forced Air Unit (FAU) is not allowed in attics of trussed roofs unless required clearances are provided. No line contact is permitted. Clothes dryer located in an area that is habitable or containing other fuel buming appliances shall be exhausted to the outside. Exhaust duct must be 4 inches in diameter and length is limited to 14 feet with 2 elbows. The duct length shall be reduced by 2 ft. for every elbow in excess of two. (MC 504, 908) Clothes dryer located in an area that is habitable or containing other fuel buming appliances shall be exhausted to the outside or to an area which is not habitable and does not contain other fuel buming appliances (not beneath building or in attic area). (MC 908) Clothes dryer moisture exhaust duct, shall be 4 inches in diameter and length is limited to 14 feet with two elbows from the clothes dryer to point of termination. Duct length shall be reduced by 2 feet for every elbow in excess of two. (MC 908) 'A 7�� -<,M4 IF-r I REVISIONS BY -61 3. 4P E < @ CY ESStp rjAR n ul No. ' 35217 CIVIL C Al- 4, g 6- �j Z� -4� Date Scale i/ Drawn /(70 Job Sheet /2- CO Off , Sheets 24X36 PRINTED ON NO, 1000H CLEARPRINT* GENERAL NOTES ALL WORK SHALL BE DONE IN ACCORDANCE W/ THE 2001 CBC, PLUMBING, ELECTRICAL AND MECHANICAL CODES, VERIFY ALL DIMENSIONS, DO NOT SCALE DRAWINGS. IT SHALL BE THE RESPONSABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON THE SITE PRIOR TO COMMENCING WORK AND IS TO NOTIFY THE OWNER AT ONCE UPON DISCOVERY OF ANY OMISSIONS OR CONFLICTS IN THE DRAWINGS. PREPARATION OF BUILDING SITE SHALL BE PER SECTION 3302 CBC.(ALL STUMPS AND ROOTS SHALL BE REMOVED FROM THE SOIL TO A DEPTH OF AT LEAST 12 INCHES BELOW THE SURFACE OF THE GROUND TO BE OCCUPIED BY THE BUILDING) ALL NAILING TO COMPLY W1 TABLE 22 TYPE OF CONSTRUCTION VN OCCUPANCY GROUP R-3 / u- - ---- ----- --- -- I O�J m of J. @ r 0 c c ;—o @ 42 Q 24 ell, ks al ma 4'- 43 Data Scale ..Drawn Job Sheet Of a Sheets 5A rI �t 8s Xa L -7 o _..me:,_,.,µ._..... 4.........w........._...�.._.._...,...,..�..,w '`..�w.......,..�....,,_..,.. ,_....u,.....,,_ .._.. . a fir* aFx:%'? f yam,, z. 54 zET�111 { M-1- 5D t 3 i I, i"wn'-z' = t al M F, �00 -11 M rz, SHEAR WALL SCHEDULE mul CTjtlN ?OF ANCHORAGE Sa SHEAR VALl. SHEATHING (2) CNK=& 6AOA $MOM PnRK1 NASM L8 3 180 7/8' STUCCO OMIT PAPM-WE0 LLTH V/Il Gal SrAPLEB • 6.O.C. TOP It aOTTDN t E.N. A F.N. M SE . 2513) 51C A8 V V O.C. IM D 6' O.0 16' A.C. 1 260 3/a• C-D.C-C PLT" Un V/U • a' O.C. RX. t Ir &t Fat. 6/r AS V 4r O.C.. tad d S• O.C. 16. O.C. t1 340 16/32' C-DC-C PLYVD 3W a/lOd 6+ a O.C. &X. & 1Zb.C. FJL a/B' Ae 0 32' O.C. lad • 3' O.C. 12' O.C. 1 490 1613r C-D.C-C PIM SUM v/8d i r O.C. LN. t X2'Q.C. TJt 518' Aa 0 24'. O.C, 0 f at a' O.C. X mo 16/32' SM I MM an V/8d 9 r O.C. T.N. & lr O.C. ,TJL i►id` Aa a ta' O.C. w W a i• QL a" O.C. 4 ` 645 16/32' STR t PLM BUID i/1Gd 0 r O c ZIt. E Ir Off. F3I. 61r a 0 ta' O.C. W uV a e at t 5 870 i6/32' STR I PLYVO 20 V/10d i r O.C. E.N. do i2' Oft F.N. 61r A8 t C O.C. SjIK' IA9a 4` X A. ALL 12TE11I01t VALL TO '8E SIII M VIM 5/r Mg. X Ir "'S 6. 'ABLE MUSE in S'l11CS AT to O.C. 1G70I1UN. AT 72' O.C. V= 7' OF Ella®IUW. iR1LES8 ONO= NO?EO. IL ALL LAC NM (121 TD U 8' LONG WrALLED VMi1 PILOT HOLE AND >fn )MUUN 2"s2 x3llr T8t{S RA79 VASHCtt UNDER NUT AN 111EN01. AT EACH 6412. L V4* 20. A.L LAY Hl MUM BY 5/8' WN. TNRE+M RODS a ALL iNTWOR TAUS WIN SHOT M- RAIL4EX' f =8, OR •/ 4-3/4' nt = WM CIA -OM 7000 SPDXY SY M BQIfIVALi:N1. AT 38' O.C. AT KUM TAUS AND 49' O.C. AT KU. ER. Wa• MR 1)QMAl,[I41y . AT THE SANE SPACING. PION-8EARINC VA= UNLESS OTHERVI3E NOTED. L 1K1A1M 1QrL18ERS OR BiACit><IO SHALL U PROVIDED AT ALL MGM C. (jt 101111111 (2) ANCHOR I MPA)EL 10 PIBVOOD, t'13 DI SEAR VALL D. COOE IIHOiIUfI 16d SOLE PLATE NABS AT fa' O.G TYPICAL AT ALL L Alt � >iAiti3. SHALL � IIANUPACTURED USOIG EXTERIOR :Lill. 6fECOND FLOOR VAUS (ux&t i. 11111121 SMki, AIM 3x 8497ty1t PLATE VIM STACMIZO BAILING E. 11Ii3tE DOU91t 21 311E P1.ATM AIM USED. PROVIDE Mg 711E ALUNAM SW VALUE lSCECDS 350 M. AMCRESM RAILING. 2 VHERE MIZAR VATEIM 13 )=AULD ON SM SIDES. THE F. ALL NAILS ARE COII)(ON NADB. �► G " A60VE p ANCHORAGE AND SLL I)p11X1ECTfON SHALL U HALF S11OVN. ilNIES° CMER4IS£ 1MQTE0 EN PLANS. ROOF ,E YWOOD DIAPHRAGM f SHEATHING)• USE 1/2' STRUCTURAL .C-D OR C-C PLYWOOD. ,MIN. PANEL INDEX NUMBER (24/0). WITH 8d NAILS AT V O.C. SUPPORTED EDGES AND BOUNDARIES: AT 12' O.C. IN THE FIELD (UNBLOCXED U.O.N.). FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO "SUPPORTS. LOOK .OR ECK PLYWOOD IAP R GIL SHE THING USE *4 ' STRUCTURAL It. C-D OR C-C PLYWOOD. MIN. PANEL INDEX NUMBER (40/20) TONG do GROOVE. WITH I0d NAILS AT 6' O.C. SUPPOMED EDGES AND BOUNDARIES. AT 10' O.C. IN THE FIELD "LOCXED U.O.N.) FACE GRAIN OF PLYWOOD SHAM. BE PERPENDICULAR TO SUPPORTS. U3F- DOUBLE FWOR JOISTS BELOW ALL PARALLEL SWARWAL13 U.O.N. ' AT FLOOR LEVELS. USE SOLID BLOCXING .AT PERPENDICULAR SHEARWALLS AND DOUBLE FWOR JOISTS AT EACH END QF THE 'SHEAR1►ALL ALL BEAKS SUPPORTING SHEARVALLS RUST BE STRAPPED TO THE WALLS BELOW. ' ALL HOLDOWNS ON UPPER LEVEL. MUST BE CONNECTED TO A POST BELOW WITH A HOLDOWN TO THE LOWER LEVEL OR TO THE FOUNDATt rzo a 3 under floor ventilation opening size a equal to I sq. ft. for each 150 sq. ft. of under floor area. Openings shall be as close to comers as practical and shall provide cross ventilation along the length of at least two opposite sides. Openings shall have 1/4 inch corrosion resistant metal mesh covering. (2306.7) Ww�a. 0 " m w v 4 1. � S O �U o a 2 n _ O Cy K ago w m ap nZ E p, r- =nW • i r -74 %�- St -2 R a 1 a is i IF-18 1 3 Z (n""t: Foundation sections 12/15/18 inches wide, 6/8/10 inches thick and 12/18/24 inch depth < F below natural ground surface or certified fill grade are required. (T 18-1-C)+ I Foundation and floor slabs on expansive soil shall conform as follows, unless approved v��^ soil report indicates soil is not expansive by the Expansion Index Test method, or <D recommends other details. (1804.4, 1806.6) a. Continuous footings under exterior walls and interior bearing walls extending below grade 24" and 18" respectively and below foundation wall crawl hole. Piles or piers are permitted without interconnected grade beams to support first floor loads only, Date Pad footing located under a reinforced slab within the confines of a perimeter footing need not be connected by a grade beam. scale b. Continuous No. 4 bars, one 4 inches from bottom and one 4 inches from top of Drawn foundation. Job 6-. Saturate the soil 18 inches deep before placing the concrete slab. Sheet Of -2 Sheets 2A x 3a PRINTM ON NO, MOM CLEARPRINTe P RE PARED B 1 RIDGE BOARD OR HIP 16d 0 1 WD. POST W/ RAFTER PER PLAN 4" O.C. 4 �A SIMP CBS, 2 /—,vs co D ��./ 2 RAFTER PER PLAN 12 E.N. SHEAR PANEL 3 PER PLAN 3 4X4 KING POST SD1 3 7 10) E 0 N 1. (2) 2X CANT. FLOOR 4 -ALA KZD) JOIST 0 STRAP 1# " Profesional Engineerf Se ry 10 4 TOP PLATE 2. TO/ PER PLAN 6 TO 4X4 POST + 5 FLUSH BEAM WHERE SSTB OCCURS WITH PC 3. SHEAR WALL 5 ANCHOR 6 SIMP PC t 6 6 WHERE OCCURS 46 ZZ (2) 2X4 STUD 7. KING POST 3- 16d F.N. TO RIPPED 0 --Flo 5. SIMP "ST" PER PLAN 3: - 6 C14 T I WALL DASHED (WHERE OCCURS) 6. 2X BLK. 2 :) IGNACIO OCHOA, F 5" FRM CORN'R Iir J-1 2 BOT. PLT. & NAIL'G 7. E.N. L tc. R C E 352 E.N. 4 3 FLR. SHT'G & FRM'G. 8. 4X4 POST —/ DASHED 0 INT, WALL Of L-A _j k ) 1 3 (WHERE OCCURS) 4 TYP. DBL. TOP PLATE 5 2X RIM JOIST 2 W/ 16d 0 8" O.C. TO TOP PLT. 6 PLY'D FLR. SHEATHING PER PLAN SEE PLAN FOR SIZE 7 SOLID BLK. 48" O.C. 3 SEE SHEAR WALL SCH. AND REINFORCING 4 FOR SHEAR TRANSFERED8 SHEAR WALL PER PLAN @ WHERE OCCURS z 13/4" FRM EDGE < PH 7 14/ 84 1 0 6L T 7692 QUEBEC E HUNTINGTON BEA( CALIFORNIA 9264 z OCHOA I OAOL. CC a w REVISIOI w 0 SHEAR WALLS %f A-JZ) PERZIMM. ZSCHEDULE0 It 0 Z� SNEAK SHEAR STRAP (�D_ FTN'G <?�?I PATIO 17 KING POST 13 HOLDOWN a FLOOR TO WALL 'CANTILEVER w oIF ESS/ 0 2 4'-0" MIN, LAP 5 No. 3521 {2) 16d STUD 2 uj 6 cr_ F8 16d 0 MIN. & _j 5 < 1( ) J: 2 —, LAP TOP LT. 5d a 161, O.C. E*.�20 'C6' a STUD MAX 5 2 v IV 4 z 0Fc­ 2 0 4X4 --A P HDR MIN.* PROVIDE 1X6 LET -IN 6 D BRAC'G (IF NO SHEAR + fm_ WALLS OCCUR) 0 60 6 7 + (0 16d 0 24" MAX. @ 45* MIN. W/ 7 Z SI (3) 8d EA. END & EA. ir O.C.FACE ---(3)16d E.N. STUD BRACE EA. NAIL TYP. CORNER 0 25'O.C. MAX. 4 Z 9 1- 2X STUD WALL PER PLAN 0 to x 2X TRIM'R & r, a: 2- 2X4 PLT. KING STUDS 11,(2) 16d E.N. PROVIDE 2X FIRE V_ 6 TO 2X SILL BLOCK WHERE WALLS 3- SHEAR WALL WHERE OCCURS 0 0 JAMB TYP. —A EXCEED 1O'H. & AT ALL 1- ROOF SHT'G 0/ 2X ROOF RFTR. 4- 2X BLK'G OR CL'G & SOFFIT LINES PER PLAN OX6 STARTER BOARD + RIM JST. < —2X STUDS -SHIPLAP- AT EXPOSED EAVES) 5- :Y4" PLYW'D SHEAT-G PER ir 0 16" O.C. 2- B.N. PLAN 0/ 2X FLR. JST, z (2) 10d T.N. 0 2X P.T.D.F. SILL PLT. 1- ST2115 0 48" O.C. IN 1- (E) ROOF SHT'G 0/ 2X ROOF RFTR. 3- (3)- 16d 0 RFTR. TIE PER PLAN W/ R-19 INS. 0 EA. SIDE STUD W/%" DIA. ANCHOR LIEU OF 2X4 TIES 2- E.N. 3 4- 2X BLK'G W/ A-35 0 0 6- G.I. MUDSCREED AT EXT. WALLS T TO PLT, BOLTS W/ 7" EMSED'T 2- B.N. 3- 2X BLOCKING (ALT.) 16" O.C.. U.N.O. 7- A-35 @ 16" O.C. 0 w 10 8- 2X4 P.T. D.F MUDSILL W/ A.B. X u PROVIDE A. B. 4- PLYW'D ROOF SHEATHING PER PLAN 6" O.C. TO BLOCK- OR- WITH PER PLAN PER PLAN W/ 21/2"X21/2" X w PER FOUNDATION PLAN. 3- 2X RIDGE BOARD 4- 2X CONT.'SHAPED'W/ 16d @ 5- 2X CEILING JST. fit It III @ 6'-0" O.C. & 41/2" z MIN. / 12" MAX. FRM. 5- ROOF RAFTERS PER PLAN 2- 16d NAILS TO EACH RAFTER 6- 08L TOP PLATE PER PLAN "At 10 0, t, 1/4" THK. PLATE WASHER z -*.,,SILL END IN LIEU OF 2X BLOCKING. 7- 2X STUDS 0 16" O.C. SEE SHEAR WALL SCHED. 9- CONCRETE FTN'G PER PLAN fi 6- 2X4 TIES 0 48" O.C. • 5- 2X RAFTER 'CALIFORNIN OR WD. BM. PER PLAN FOR SHEAR TRANSFER 0 MIN, 10- (2)04 REBAR TOP & BOT. w 7- 3- 16d TYP. SHEAR WALLS w 8- CJ / TIE PER PLAN W/ 4- 16d FRAMED 8- SHEAR WALL PER PLAN z m ------------------------------------- 6- PLYW'D SHT'G PER PLAN WHERE OCCURS TO RAFTER cn w Ca 'CALI FORN IA' FRAMED ui EXTERIOR BEARING WALL 18 RIDGE 14 10 SHEAR TRANSFER EXTERIOR FOOTING 3: FRAMING ROOF AT EAVE o OUTER 1/3 MIDDLE 1/3 OUTER 113 z O_F_ SPAN I OF SPAN OF SPAN ONLY T 3 (2 ROWS) SHR. WALL 0 AT TOP OR SOT NO NOTCHES AT TOP OR SOT 1 1�1 WHERE OCCURS < ALLOWED U.N.O. 2 0 S.N. 2 U- 0 2 "D 0 1 EN 4 N. 5 EXISTING z _ I — I - I z + La<11 + + N R w ONLY SPAN OUTER 1/3 MIDDLE 1/3 OUTER 1/3 NOTCHING 4 1. 2X OR 3X STUDS PER PLAN OF SPAN OF SPAN OF & S.W. SCHEDULE z 6 AT TOP OR SOT NO NOTCHES AT TOP OR BOT 2 m 7 w ALLOWED U.N.O. 12 2. EX 9 (5) 16d 5 to 1- 2X STUD WALL WHERE OCCURS w PER PLAN w 3. B.N. _j toot 1- RFTR. AND CEILING JOIST 2- 2X4 PLT. 0: 5 S.N. PER PLAN 3- SHEAR WALL WHERE OCCURS 4- 2X BLK'G OR FLOOR JST 2- EXIST'G ROOF SHIT'G w 5. PLY'D SHT'G PER PLAN x 3- NEW FLUSH BEAM PER PLAN 5- PLYW'D SHEAT'G PER 0 0_r PLAN 0/ 2X FLR. JST. 6 2- 2X RAFTERS NAILED TOGETHER 4- NEW SIMP U26-2 TO z POST/CRIPPLE POST PER PLAN % 10 7 12 R�R. & C.J. & 2X BLK'G PER PLAN W/ R-19 INS. w 7 2- 2X TOP PLT. 6- 2X SLK'G 0 16 O.C. AT PARALLEL F.J. OWN 2. SIMPSON ST PER PLAN U. TO W/ SIMP PC 2X LARGEST 2 / --- \ 0 W/ 12- 16d @ EA. END OR TO CRIPPLE WHERE BORING 8. SIMP. A35 @ 16" O.C. 7- A-35 a 16" O.C. MST W/ 17- 16d 0 EA, END. OCCURS BORE DIA. (1 10 8- 2X4 P.T. D.F MUDSILL W/ A.B. 0 3 ++ MIN. 9. SIMP A35F 0 16" O.C. PER PLAN W/ 21/2"X21/2" X w - DBL 2X BLK'G 1/4" THK, PLATE WASHER 10. CL'G JST. PER PLAN MIN 9- CONCRETE FTN'G PER PLAN FRACTION JOIST 2X6 2X8 2XIO 2X12 2X14 11. WALL FINISH PER PLAN 10- (2)*4 REBAR TOP & BOT. OF 7/8­ 11/8- 2001CBC D/6 11/2" lYs" 21/81* SECTION 2320.8.3 12. SOLID SLK'G Z it/ .. 2%l' 4 SP�: S T 0/3 4 3" 3 -Y4 F- STRAP 19 BORED, OR NOTCHED JOISTS NTS 15 SHEAR TRANSFER FLU5H 5"EAM INTERIOR FOOTING z 0 2 3 (a 3 W Jos DESCRIPTI, 16d z 4 0. It". < 7 1. 'SIMP* EPDXY -TIE TO E.N. w 2 BORED HOLES MAX 40Z OF STUD it 14W Sm RF8 *5X8 W/5" MIN. 6 WIDTH @ BEARING WALLS, 60/ MAX. EMBEDMENT DEPTH 0 NON -BEARING WALLS. TO CONC. AT 4 V2" MIN. II II CY FROM END, 12 " MIN. MIN, z FROM EDGE. SPACED PER 0 6 NOTCHES- MAX. DEPTH 257 OF STUD — — — 3 w FOUNDATION PLAN WIDTH 0 BEARING WALLS, 40/ MAX. 0 CL z [T* NON -BEARING WALLS. W W 2. EXISTING CONC. FOOTING 0 m 0 4 SEE SHEAR WALL SCHED. 0) w 3. END RIM JST. OR BLK'G FOR SHEAR TRANSFER @ Z 10 DETAIL, STUD SHEAR WALLS 2f :2 4 4 r 1 4, 16" LONG 2X SHIM OR 60 :2 0 2X BLOCK — - I 2X BLK'G W/ 16d 0 8" O.C. =:9 6 TO LEDGER,TYP. CC 1/4""1'- z 6 1- 4X4 POST WHERE 0 8 2. 1 , ir 2 SIMP TS9 0 48" O.C. r OCCURS W/ ST6215 =7 IL 7 EA. SIDE 3 2X LEDGER W/ 2 -16d 2 —111 NOTES, E.N. PLY'D FLOOR 2- FLR. SHEATING PER >_ 0 EA.STUD IL SHEATHING PER PLAN PLAN 0/ 2X6 F.J. @ z 4 2X BLK'G 0 48" O.C. — J 11- A. DRILL HOLES PER UNRIF.SPECS. t— 75W 16" O.C. W/ R-19 INS 4 r, m-= F_ I J uim ft S. ­­ ­_ ­ ­ 2 FL. SHT'G & FRM6G. rl AtAlhL i- 'SIMPSON' NO. POST BOLT z I CONC. I BOLT er Lei HB s B I MIN. PST I SIMP. SSTB MAX. LOAD HD2A (2)% % 12" 4V2 1/2 4X4 16 2775 HD5A (2) y4 )/4 16" 51/4 3 4X4 20 4010 H06A (2) y8 3(a 2 4 " 6/a 31/2 4 X6 1 28 5510 H08A (2) yg %8 24" 61/831/2 4X6 28 7910 HD10A (2) ya Y8 24" 61/8 31/2 4X6 28 9990 5 CONT. SHEARPANEL W/ BLK'G & E.N.@ PLY'D SHR. WALL ONLY 6 2X RR PER PLAN 7 ROOF SHT'G PER PLAN 8 2X STUDS a 16" O.C. FRACTION 2X4 2X6 2X8 OF STUD NOTE,. NOTCH & BORE NOT TO OCCUR ON SAME STUD WITHIN 36" OF EACH OTHER. 1 )nni rear almralum L SET EPDXY coo *5279 A4 DASHED 0 INT. WALL (WHERE OCCURS) 3'1 WALL DASHED (WHERE OCCURS) A-35 PER SHR, SCHEDULE t: I 1� 3- 2-2X BLK'G 4- 4X GIRDER PER PLAN 5- A-35 EA. SIDE 6- 8"X 8" X2" P.T. PLATE 1 W/ %" DIA A..B. 11 251 1) !1A 1 3/a IYa" 4 OZ D 1%­ 2!/ 3" A 607 D 2" 31/4" 41/4" 9 WALL FINISH PER PLAN SECTION 2320.11.9- 2320.11.10 5 SHEAR WALL PER PLAN 7- CONC, PIER 10 2X BLK'G WHERE OCCURS 1 SQ. 8- 4X4 CRIPPLE POST 11 E.N. 6 FLOOR JOIST PER PLAN W/ 2- A35F TO GIRDER 7 2X BILK. SHEAR TRANSFER 0 BORED OR NOTCHED STUDS NTS A.B.T EXISTING FTN'G 2- 16 12 SHEAR TRANSFER @ CONCRETE PIER [:4 FLI QQQ IQ 141411 d " 7 1/2 " 1. 31Y2 " 115-21/2 NEWEL POST -4� 31YI STUCCO ia/ BLM @ 48" O.C. MAX W/ 3/4" FLYWOOD PAPER 4." M* TREADS if RISERS T--T] TT Z BAR FLASH'G 4 — 51I I�r PER PLAN 28 GAUGE G.I. PAN FLASH 2-2,x TOP M-ATE BEM SEE PLAN 7 (2) 1'/4" SO. UPRIGHTS W/ S" MIN. w/ 8" LAP A CRIMP 11/4" SPACE, 0 7/2" O.C. BLDG. PAPER o/ 0 rn X' I x4p NAILER SIMP5014 ECG WL" CAP 2xI4 STRINGER to 16" O.C. MAX. 2x c; 11105 — -a TOP & BOT. RAIL CONT. WALL TO WALL W/ CONCEAL'D ATTCH'T —4 �� — - — - — - — — - GOLPER KM " TO SOLID BLOCK'S BY FRAMER. ZX ROOP6 SEE ATTACHEMENT SHALL WITHSTAND 20 LBS FT -A�, , I ROOF PLAN 4x -5iRV OR f3L0(X;W9 5tt4�N M5T OR EG, - OF LATERAL FORCE I FI.AN co FRAMG SEE 2--)x TOP R.ATE STRUCT. NOTE* PROVIDE SAMPLE FOR OWNER. APPROVAL rl SECTION ELEVATION d ALL WD. PAINT GRADE 2x 5TUIX5 — NOT TO SCALE 13 SECTION STAIR STRINGER ROOF TO WALL ETA{ R HAN D RA{ L STUCCO ol BLDG. I BLK'G W/ (3) 2" DIA HOLES 3/4" PLYWOOD PAPER of G.I. BREED w/ WEEP HOLES W/ G.I. SCREEN BACK'G WHERE OCCURS,' KEEP INSULATION CLEAR I" MIN. TREADS A RISERS 2 4:12 MIN. PICTH- LT. WT. CONCRETE TILE PER ELEVATION 0/ *30 FELT UNDERLAYEMENT P.T. DF. SILL 2 SLAB WHERE 3. 2X RO.SO. FASCIA (SEE EXT. ELEV) 30', MAX OCCURS CONC. SLAB C STUCCO EXTERIOR Or SEE EXT.ELEV. BLD'G PAPER 5 1X6 STARTER BOARD SHIPLAP AT EXPOSED EAVES DOUBLE FLR. JST. 6 G.I. EDGE DRIP 2xI4 STRINGER 1-4" O.C. MAX. w/APPROVED 7 INSULATION PER TITLE 24 HANGERS W > 8 STUD WALL PER PLANS W 9 GYP. BD. INTERIOR FINISHGRADE WHERE OCCURS :1 3 7 0 FIE"jj 0 4 8 14 SECTION STAIR STRINGER 10 WEEPSCREED SAVE Y=11--O" 2x4* 16" O.C. CONT. BLDG PAPER o/ G.J. ROOF'G SEE ROOF PLAN W' VALLEY FLASHING WI CRIMPED EDGES ua O1: 2x12 STRINGER z "= - uj VERIFY WADWER FRAM*G PER STRUCT. e33 16d/JST 6 GUARDRAIL 19 15 VALLEY FLASHING HANDRAIL AS SELECTED BY OWNER w/ APRRV'C> STUCCO 0/ BLDG. J 1/211 1#0 2 SUPPORTS TERMINATING PAPER IN NEWEL OR # MIN. SAFETY POST 0.1. FLASH ol tj I X BLCK Zr ROOF'G ol V6 9 BLM PAPER W- u- 2- 3/S" LAG SCREWS 2411 O.C. MTL CLSR PRVIDE SOLID STRIP OR BACKING MORTAL FILL 6 'S' TILE IMF— Handrails shall satisfy the following: HANDRAIL TIO WITHSTAND MIN, 200* LOAD IN ANY DIRECTION Return handrail to newel Post or wall. 20 16 INT. HANDRAIL N.T.S. 8 ROOF TO WALL PREPARED BY: ri n OCHDA 0 //-Z:zsD�TI U9 Profesional Engineering Services 0 IGNACIO OCHOA, PE Lic. RCE 35217 z < PH 714/ 841 0643 7692 QUEBEC DR HUNTINGTON BEACH CALIFORNIA 92648 Z OCHOAIOAOL.COM WLu REVISIONS uj a 0 x IL 0 F- 0: 0 cc a. 0 1 F ESSI GXR -j 0 Q No. 35217 > rn Exp fi3p z —4- 0 OF z SITE: (L 0 CC 0 z 0 0 ir uj 0 0: u W z 0lr eo U1 z C) W U) W 0 F- z 0 0 z z t W Ct W z W % 7; to" 4WNER: W 5) z a. W 0 z 0 in O cc 0 cc x LLI z JOB DESCRIPTION: AS SHOWN —DRAWN:-- 1.0. CHECKED: DATE: JOB NO: JUN-21-04 SHEET NUMBER: AD-1