HomeMy WebLinkAbout10148437.pdf1. Interior walls and ceiling finish Flame Spread rating shall conform to the requirements of UBC Chapter 7 Flame spread -Class iII, Smoke Density-450. 2- All exits sholl be openoble from the inside without the use of a key or any special knowledge or effort (UBC 1004.3). J. Provide a durable sign over the exit doors statingq 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" (UBC 1004.3). 4. Double doors shall be provided with approved automatic flush bolts; Manually operated flush bolts ore prohibited (UBC 1004.3). 5. All doors shall have a min. 60" level landing on the swing side of the door and 44" min. on the opposite side (UBC 1004-3). 6. All door hardware sholl be lever type or panic bar hordware(UBC 1004.4). 7. All doors with glazing sholl be provided with a min. 10" high smooth uninterrupted surface at the bottom. 8. Door thresholds shall be a maximum height of 112' (UBC 1004.9). 9. Low consumption water closets shall be provided where new plumbing fixtures will be installed 10. Provide exit illumination & signage per UBC 1012 & 1013. I I. Provide panic hardware per 1016.4 UBC. 12. Signs & canopies are under separate permit. 13. Post occupant load sign per 1002.3 UBC. VICINITY MAP 120' ALL PARKING SHOWN IS EXISTING TOTAL PARKING PROVIDED=36 STD. STALLS (INCLUDING 2 HC PARKING STALLS) z w o_ 0 n X NOAART Z io z 81 00 r�r//rrrrrs/ { Il r //PRICE 4 COMPUTERS/ j a rrrr/rr/rrrrr/rr rrr/ /rr jrr r vF=i X /f 'Till/ r/r/rrrr r/ LL, 0 - i `�! GRANS A I NOTE. SEE SHEETF+-4 FOR ACCESSIBLE PARKING REQUIREMENTS SITE PLAN ��l � 1s�S 1� ASV 1575 9 V� JszS 1 Provide and install fire extinguishers with a min. copocity of 24-108C rating at locotions determined by the fire inspector. 2- Provide conspicuously mark gas shut-off valve. 3. Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving on occupant load of 50 or more. Title 24, 1004.2 4. Exit doors shall be openable from the inside with out use of key or any special knowledge or effort. Title 24, 1004.3 5- Width and height of required exit doorways to comply with Title 24, 1004.6 6. Provide approved panic hardware on required exit doors. Title 24, Sections 1016.4 & 1004.4 7 Provide an approved fixed fire extinguisher system for the kitchen hood, ducts and cooking surfaces- Indicate U.L. approval, system number, and submit U.L. approved schematic drawing to area inspection unit. Fire code section 1006.2 8. interior finish sholl be provided in accordance with Title 24 Section 804, as follows: Class I - Vertical Enclosures, Class 11 - Rooms 9- All drapes, hangings, curtains, drops and all other decorative material to comply with Fire Code Section 1103.3.3 10. Comply with posting of room capacity. Fire Code 2501.16.1 Title 24, Section 1002-3 11- The maximum occupant load for an assembly use shall not exceed the occupant load as determined in accordance with Title 24 Section 1002.2 ARCHITECT ARCHITECTRONiX INC. JOHN M. RIX, NCARB 250 NORTH GOLDEN CIRCLE DRIVE, SUITE 204 SANTA ANA, CA 92705 (714) 836-0702 (714) i}3EiI4 FA7k WiASTER UIS(11 'A _ s _ w _ 6 ­x PROJECT TEAM ZONING. C-5 COMMERCIAL ARTERIOL BUILDING HP 15 FT. CONSTRUCTION TYPE: V-5 BUILDING SF SF PRICE 4 COMPUTERS SPACE 5461 SF RETAIL SPACE 3211 SF TOTAL SF 8672 SF OCCUPANCY OCCUPANT LOAD OCCUPANTS EXITS REQ'D. RETAIL - M 4736 SF 30 SF/OCC 157 2 OFFICE -- B 725 SF 100 SF/OCC 7.25 1 NO OCCUPANCY SEPARATION 164.25 TOTAL (BASIC ALLOWABLE FLOOR AREA INCREASE - 507 FOR 2 SIDE YARDS > 60' = 8000 + 4000 = 12,000 SF) EXITING 164.25 x .2=32.83" REQUIRED EXIT WIDTH- 100" PROVIDED IN TWO EXITS. PARKING 29 SPACES REQ'D 36 SPACES SUPPLIED ItUILDIN G DATA ABV above LTL lintel AFF above finished floor LL live load ACC access LOC location AP access panel LVR louver ACT acoustical We MAX maximum ADJ adjacent MB machine bolt AGG aggregate MH manhole A/C air conditioning MFR manufacture (er) ALT alternate MAS masonry ALUM aluminum MO masonry opening AB anchor bolt MAT material (s) APPROX approximate MAX maximum ARCH architect (ural) MECH mechanic (ai) AD area drain MET metal ASPH asphalt MIN minimum BRG bearing MISC miscellaneous BPL bearing plate NAT natural BM bench mark N north BLK block NIC not in contract BLKG blocking NTS not to scale BO bottom of OC on center (s) BOT bottom OPG opening BLDG building OJ open web joist BM beom OPP opposite BUR built—up roofing OPH opposite hand CAB cabinet OD outside dimension CPT carpet (ed) OA overall Cl cast iron OH overhead C8 catch basin PL plate CLG ceiling PNL panel CEM cement PB panic bar CER ceramic PAR parallel CT ceramic tile PTN partition CIR circle PVMT pavement CLR clear (once) PED pedestal COL column PERF perforate (d) CONC concrete PLAS plaster CMU concrete masonry unit PIL plastic laminate CONST construction PL plate CONT continuous or continue PG plate gloss CONTR contract (or) PLYWD plywood DL dead load PC pipe column DEM demolish, demolition PSF pounds per square foot DEP depressed PSI pounds per s uore inch DEL detail PFB prefabricate �d) DIAG diagonal PT pressure treated DIAM diameter PL property line DIM dimension QT quarry tile DPR dispenser RAD radius DN down REF reference DR door RFL reflect (ed), (ive), (or) DS downspout REFR refrigerator DF douglas fir REG register EA each REINF reinforce (d), (ing) E east RCP reinforced concrete pipe ELEC electric (at) RES resilient EP electrical ponelboard RET retaining ELEV elevation RM room EMP employee RO rough opening ENCL enclosure (ure) SCH schedule EQ equal SEC section EQUIP equipment SS service sink EXH eshoust SHTH sheathing EXIST existing SHT sheet EB expansion bolt SiM similar EXP exposed SC solid core EXT exterior S south FD floor drain SPL special FOC face of concrete SPEC specification (s) FOM face of masonry SQ square FOS face of studs S/S stainless steel FF finish floor STD standard FE fire extinguisher STA station FiN finsh (ed) STL steel FTG footing SD storm drain FSE food service equip. STRUCT structural FIR frome (d), (ing) SUS suspended FS floor sink SYM symmeiry (ical) FUR furred (ring) SYS system GA gage, guage TKS tockstrip Gi golvarrized iron TEL telephone GC general contract (or) TG tempered glass GL glass, glazing T&G tongue and groove GD grade, grading TO top of GYP, BD, gypsum board TS top of sheathing HC hollow core TSL top of slab HWD hardwood TST top of steel HDR header TW top of wall HVAC heating/ventilating] TYP typical air conditioning UC undercut HT height UR urinal HC hollow care VJ v—joint (ed) HM hollow metal VB vapor barrier HORZ horizontal VERT vertical HB hose Bibb VB vinyl base iNCL include (d), (ing) VT vinyl tile ID inside diameter WSCT wainscot INSUL insulation WH wall hung INT interior WC water closet JT joint IMP waterproofing J joist WR water resistant KPL kickplate Wf with LAD ladder W west LB log bolt WIN window LAM laminate (d) WG wired glass LAY lavatory WM wire mess WO without (N new WD wood (E� existing LEGAL JURISDICTION: BULDING CODE SANTA ANA, CA 2001 CBC 2001 CMC, CPC 2001 CEC OCCUPANCY: B - OFFICE M — RETAIL NO OCCUPANCY SEPERATION REQUIRED TYPE OF CONSTRUCTION: TYPE VN SPRINKLERS: PLANNING ZONE SITE AREA: SITE COVERAGE LANDSCAPE AREA - M COMMERCIAL 27,373 SF (NO CHANGE) XX.X% BUILDING NO CHANGE ARCHITECTURAL T-1 TITLE SHEET / SITE PLAN A-0 EXISTING SITE PLAN A-1 FLOOR PLAN, / REFLECTED CEILING PLAN A-2 DETAILS FA-1 FACILITY ACCESS REQUIREMENTS FA--2 FACILITY ACCESS REQUIREMENTS no ARMECTURAL This t Of 009 a0d SPOrcafts must be kept an ft !. a, is umawful-to make City of Santa Anon The aecaptanCe of this plan SHEET INDEX ® WOOD ® PLYWOOD METAL STUDS BAIT INSULATION BOARD INSULATION CERAMIC TILE ® STEEL CONCRETE CONCRETE MASONRY UNITS ASPHALT PAVING SOIL INTERIOR ELEVATION DESIGNATION 4 ®2 SHEET NUMBER 3 --- us Ma EXISTING DIMENSION VERIFY IN FIELD SECTION NUMBER SHEET NUMBER F KEY NOTE Q COLORfMATERIAL DETAIL NUMBER SHEET NUMBER 0 DOOR NUMBER 0 EQUIPMENT/ACCESSORY y « ■M ■ ■ NEON ■■ MEN ■ MEN ■■ �■ ■■ Aimmik WIP&I 00000MONN ARCHITECTRONIX, INC 2030 N. TUSTIN AVENUE SUITE & SANTA M& CA 92705 7'141&36° M REVISIONS All ideas, drawings, and specifications shown hereon are the property of Architectronix and sholl not be used, copied, reproduced, or disclosed to any person, firm, or corporation, without the written consent of Architectronix. Any infringement will be subject to legal action. Contractors shall verify and be responsible for all dimensions and conditions on the job and notify this office of any variations from dimensions and conditions shown herewith. Written dimensions take precedence over scaled dimensions. �1 J DATE 005 "S*OP` CAl 1 OWN LLJ Z w �y a? , L L. 0 U Z CtC .�, L r.R)C Lf) . --.. C LO CN It'n }-- DRAWN: RIX SCALE NOTED JOB NO.: DATE 4115199 RELEASE DATE: CAD NAME 28301TI SHEET NO.: Tol MM 1:0 -{ RESIDENTIAL CONC. BLOCK WALL. _ 120' E I 4 l � I i { ALL PARKING SHOWN IS EXISTING I : TOTAL PARKING PROVIDED=36 STD. STALLS �j (INCLUDING 2 HC PARKING STALLS) { 1 ir) CHAIN LINK FENCE CHAIN LINK FENCE a� I I I a I co I —(E) OVER ANG I NOT A PART Z -00 { 56'-0" /2-9 /0/ / G-RAfki'b KVF. /PRlt �4 /C(1MPU/TE 2S/ / r / / CL U o LINE OF CANOPY ABOVE I 8'-b 20'-O" 28,-0" Z U Q I PUBLIC TELEPHONE f'E"i BIKE RACK /OI / /�I F CF/ EN �, POLE SIGN P / f 1 l �NpSCAPE Y I .� '�—(E) OVER SCE TRANSFA1.K23� WATER METER --''CONCRENF- t) ATf&T MAN HOLE SID j [ IN F.O. CURB�1,/ 1001111MGMEM 17e�ii1_1 ADDRESS: 2520 N. GRAND AVE , SANTA ANA CA. API 396-111-60 PARCEL 2 IN THE CITY OF SANTA ANA, COUNTY OF ORANGE STATE OF CALIFORNIA, AS SHOWN ON PARCEL MAP FILED IN BOOK 18, PAGE 47 OF PARCEL MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY ZONING: C-5 COMMERCIAL ARTERIOL BUILDING HT: 15 FT. CONSTRUCTION TYPE: V-5 BUILDING SF SF PRICE 4 COMPUTERS SPACE 5461 SF RETAIL SPACE 3211 SF TOTAL SF 8672 SF OCCUPANCY OCCUPANT LOAD OCCUPANTS EXITS REQ'D. RETAIL — M 4736 SF 30 SF/OCC 157 2 OFFICE -- 8 725 SF 100 SF/OCC 7.25 1 NO OCCUPANCY SEPARATION 164.25 TOTAL (BASIC ALLOWABLE FLOOR AREA INCREASE — 50Y* FOR 2 SIDE YARDS > 60' = 8000 + 4000 = 12,000 SF) EXITING 164.25 x .2=32.83" REQUIRED EXIT WIDTH! 100" PROVIDED IN TWO EXITS. PARKING 29 SPACES REQ'D 36 SPACES SUPPLIED 1w s �..- 0 NORTH SITE P I SCALE. 1 j16"= 1'—O' N00000000 ■ ■ ■��i ■■ ■M■ ■ MEN ■■ ■■ ■ ■■ qM N MMM NOMMOMENE ARCHITECTRONIX, INC 2030 M TUSTtN AVENUI SUITE & SANTA ANA: CA 92T05 7W8%-0M REVISIONS All ideas, drawings, and specifications shown hereon are the property of Architectronix and shall not be used, copied, reproduced, or disclosed to any person, firm, or corporation, without the written consent of Architectronix. Any infringement will be subject to legal action. Contractors shall verify and be responsible for all dimensions and conditions on the job and notify this office of any variations from dimensions and conditions shown herewith. Written dimensions take precedence over scaled dimensions. R x . C 1723 s f Of— CA �1 LLj 0 L .. ::E < '. 0 C) __RJ Uzu V < CL, �i s U LLJ ""*am C)z C.14 V) C LO cv cryLin DRAWN: RIX SCALE NOTED JOB NO.' DATE 4115199 RELEASE DATE CAD NAME: 28301A0 SHEET NO. I REMOVE (E) STORAGE GATE & FENCE LINE OF CANOPY ABOVE DRFAT STOPS - PER CBC SECTK :3000 SF MAX. SEE 12/A2 AND T. A2 WALL LEGEND NEW MTL. STUD WALL (PARTITION WALLS) SEE CALL OUTS EXISTING PARTITION WALLS NOTES: Iwo= EXISTING WALL TO REMAIN. 1. FOR CEILING FINISHES AND REMOVE ALL FINISH MATERIALS. SPECS. SEE FINISH SCHEDULE SHEET A3 PREPARE FOR NEW FINISHES. 2. ALL LIGHTS ARE EXISTING. NOTES: EXIT ILLUMINATED EXIT SIGN PER 2001 CBC SECTION 1003.2.8 1. SEE DOOR SCHEDULE SHT. FA3 E.■.N...■ No MEN M A MEN ON ON 0 N IN 1:0 am. ENNEMENNE MCHIHMONIX INC 2030 K'rUSnNAVENUE SUITE & SAWA M& CA MS 7U/a3l"M REWSIONS All ideas, drawings, and specifications shown hereon ore the property of Architectronix and shall not be used, copied, reproduced, or disclosed to any person, firm, or corporation, without the written consent of Arch'itectronix. Any infringement Will be subject to legal action. Contractors shall verify and be responsible for all dimensions and conditions on the job and notify this office of any variations from dimensions and conditions shown herewith. Written dimensions take precedence over scaled dimensions, AR 01&-0172 L (P R DATE 1 ftemi OF C Namwa LLJ U LLWJ U LLMJ LAMM LLJ CL U-J- 0 > LL. .4 0 U Z U CL. lr4tt z 0 LLJ • U C) z Mai , < U.. CL. CN V) DRAWN SCALE NOTED JOB NO. DAM 4114199 RELEASE DATE 28JOIA1 CAD NAME SHEET NO. Awl FLOOR PLAN�� 1 REFLECTED CEILING PLAN��2 1 T� T AN WOMENS RESTROOM 108 nrrrnnnis rner Lx BRAILE BRAILE WOMEN LETTERING MEN LETTERII` 121/ �'--- 12" ---4 A B DISABLED ENTRANCE SIGN C D DISABLED DIRECTIONAL SIGN SCALE N.T.S. EO 101 NOTE: NOTE: SEE KEYNDTES .141-. EXISTING RESTRODM 1SCALE -� DRAFT STOP 114 „� 11_ 01 SOAP DISPENSER BDBRICK MODEL NO, B-85 WALL FINISH FLOOR FINISH PER FINISH SCHEDULE HANDICAP APPROVED WATER CLOSET PER PLUMBING PLANS AND SPECIFICATIONS V SURFACE MOUNTED STAINLESS STEEL PAPER TOWEL DISPENSR, BDBRICK MDDEL NO. B-263 W1 SATIN FINISH fZ WALL HUNG SINK PER PLUMBING PLANS j THERMAL INSULATE HOT WATER SUPPLY AND DRAIN LINE 7 SURFACE MOUNTED TOILET PAPER HOLDER, BDBRICK MODEL NO. B-273 ALUMINUM W1 SATIN FINISH SURFACE MOUNTED 18x30 MIRROR BDBRICK MODEL NO. B-166-1830 8 0 STAINLESS STEEL W1 SATIN FINISH WITH FRAME SURFACE MOUNTED GRAB BAR, BDBRICK MODEL NO. B-6806 SERIES, STAINLESS STEEL W1 SATIN FINISH WITH SERIES ANCHOR PLATES IO 6" HIGH SELF COVED SHEET VINYL 11 PAINT HIGH GLOSS ENAMEL NOTES; PROVIDE SOLID BACKING FOR ALL WALL HUNG ITEMS WASHROOM EQUIPMENT PROVIDED BY OWNER, INSTALLED BY G.C. CONTRACTOR TO VERIFY WITH OWNER FOR ACCESSORIES, 191 KEYNOTES SCALE SCALE SCALE NONE 181 NONE DOOR MARK DOOR SIZE DOOR MATERIAL FRAME MATERIAL HARDWARE FRONT ENTRY DBL3 x7' EXIS"ALUM.1 GLASS MTL. per door manufacturer OFFICE 3'x6'8" NEW SC. WOOD timely mtl. GROUP I (SEE BELOW) RESTROOM 3 x6'8" EXIST SC. WOOD timely mtL GROUP Il (SEE BELOW) REAR EXIT 3 x6'8"EXIST. MTL. timely mtL SEE NOTE 12 & 3 WAREHOUSE 3 x6'8"EXIST. WOOD timely mtL SEE NOTE J2 & 3 iOOR OPTIONS (VERIFY WITH FRANCHISE) fETAL FRAME AND SOLID CORE DOOR IASONITE DOOR ROUP 1: STANLEY HINGES SCHLAGE LOCKSET #AL53 PD SAT 625 IVES WALL MOUNTED DOOR STOP HARDWARE SHOULD BE BRUSHED CHROME FINISH ROUP N: STANLEY SELF CLOSING HINGES SCHLAGE LOCKSET JAL40S SAT 625 IVES WALL MOUNTED DOOR STOP HARDWARE SHOULD BE BRUSHED CHROME FINISH TOTE 11: LANDLORD SHOULD PROVIDE A SELF CLOSING HINGE/HARDWARE IF REQUIRED BY COI TOTE 12: GENERAL CONTRACTOR SHOULD PROVIDE A "PEEP HOLE" IN REAR EXIT, AS WELL AS, AN ANNOUNCER ON THAT DOOR FOR SECURITY PURPOSES, AS REQUIRED. !OTE 13: LOCAL CODES MAY REQUIRE USE OF DETEX BRAND PANIC HARDWARE FOR REAR SERVICE DOOR. IF NOT REQUIRED, USE OF DEAD BOLT OR LOCKING BAR IS RECOMMENDED FOR SECURITY. DOOR AND FRAME SCHEDULE 15 14 13 1 Lr xuut v��n E) ROOF STRUCTURE E) BM OR ROOF JRUCTLRE t'c' GYP. BD. DRAFT JOP OR EQUIVALENT SATERIAL PER SECTION 08 OF CBC, i icornmrn rrzi Mr. SCALE NONE 12 GAUGE VERTICAL HANGER WIRE MINIMUM 3 TIGHT TURNS IN 1 1/2" AT VERT. MAIN RUNNER CEILING TILE CROSS RUNNER PROVIDE STUD -- BLOCKING @ CLG. i LAY -IN CEILING WHERE OCCURS SEE CLG. PLAN HOLD GYP. BD. - CLEAR 3/8" AND CAULK CONT. SCALE: 3"=1'-0" ' 12 SUSPENDED CEILING AT INTERSECTION J"SCALE WALL PAR TI 8" MAX. OR 1/4 OF THE LENGTH OF THE END RUNNER WHICHEVER IS LEAST NOTE: THIS CONDITION OCCURS OPPOSITE FREE END CONDITION, SEE ASSOCIATED DETAIL FOR FREE END CONDITION �--- 12 GAUGE HANGER WIRE MINIMUM 3 TIGHT TURNS IN 1 1/2" AT VERT. HEADI�B MAIN OR CROSS RUNNER CEILING TILE WALL ANGLE POP RIVET MAIN RUNNER OR CROSS RUNNER TO WALL ANGLE WALL CONNECTION, ANCHOR TO STRUCTURAL SILL ELEMENT - -- ABUTTING WALL 11 SUSPENDED CEILING AT FIXED END 3 SCALE 7 8" MAX. OR 1/4 OF THE LENGTH OF THE END RUNNER WHICHEVER IS LEAST 12 GAUGE HANGER WIRE MINIMUM 3 TIGHT TURNS IN 1 1/2" AT VERT. SLOTTED ANGLE SPACER WITH HORIZONTAL 6d RING SHANK NAIL (NAILS AT END OF HORIZ. STRUTS ARE TO BE PLACED W/ NAIL HEAD TOWARD C/L OF SPAN OF STRUT) ALTERNATE LOCATION W/O NAIL NOTCHING PERMITTED ONLY AT RUNNER MAIN OR CROSS RUNNER WALL CONNECTION, ANCHOR TO STRUCTURAL ELEMENT WALL ANGLE CEILING TILE NOTE: THIS CONDITION OCCURS OPPOSITE FIXED END CONDITION, SEE DETAIL 2/AD1 FOR FIXED END CONDITION ABUTTING WALL 10 SUSPENDED CEILING AT FREE END 3 scALEC 6 TYPICAL 12 GAUGE STEEL VERTICAL HANGER WIRE AT 4'-0" O.G. MAX., EACH WAY, WITH MIN. 3 TIGHT TURNS IN 1 1 /2", BOTH ENDS OF WIRE .------- MAIN RUNNER RIGID VERTICAL STRUT, 12'-0" O.C., EACH WAY, MAY BE A STEEL STUD, BLACK IRON, EMT. OR OTHER APPROVED EQUAL •< 12 GAUGE LATERAL BRACING WIRE WITH MINIMUM 4 TIGHT TURNS IN 1 1 /2" BOTH ENDS OF WIRE, TYPICAL .:.. :• 2" MAX. FROM BRACING WIRES TO • CROSS RUNNERS GROSS RUNNER NOTE: METAL SUSPENSION SYSTEMS FOR ACOUSTICAL LAY -IN PANEL CEILINGS SHALL BE INSTALLED PER U.B.C. TABLE 47A, AND 23P, STANDARD 47-18, AND I.C.B.O. NUMBER ER-1905 NOTE: SEE ASSOCIATED DETAILS BELOW FOR ADDITIONAL INFORMATION (�/,,•�/{�, SUSPENDED CEILING, BRACING - SCALE 5 ✓ 3/8 11= 1 1- h 1, ROOF STRUCTURE (3) #8 PAN HD. SCREWS TYP. @ 48" O.C. 3 5/8" X 18 GA. MTL STUDS @ 48" O.C. METAL TRACKS ATTACHED TOGETHER W/#3 PAN HEAD SCREWS (TOP & BOTTOM) GYP. BD. CEILING, WHERE OCCURS. SEE CEILING PLAN 5/8" GYP. BD. WITH 3 5/8" 20 GA. MTL. STUDS @ 24" 0. C. 77 (ICBO J1715P ANGELUS METAL SYSTEMS), TYP. — CONT. UNPUNCHED TRACK W/ HILTI POWDER DRIVEN FAST # DN72 W/.080"X1.10" SQ. WASHERS @ 32" O.C. (ICBO# 1290) g 4 �� � � SCALE WINDOW JAMB -HEAD TYPE "X" GYP. BD. 2" - 25 GA. MTL STUD @ D.C., U.N.O. :LY" MTL. TRIM TO MATCH MTL. WINDOW FRAME T ENAMEL (COLOR TO BE RMINED) TEMP. CLEAR GLASS :LY" MTL. WINDOW FRAME T ENAMEL (COLOR TO BE RMINED) TYPE "X'° GYP. BD. SCALE N.T.S. '2'° - 25 GA. MTL. STUD @ D.C., U.N.O. :LY" MTL. TRIM TO MATCH )WARE REINFORCEMENT, AS REQ. 1Y" MTL. DOOR FRAME T ENAMEL (COLOR TO BE DETERMINED) WHIN DOOR .JAMB -HEAD SCALE12 N. T. S. 1/2" GA. MTL BRACING @ 45' TO U?/2 SIDE OF STRUCTURE ABOVE, ALTERNATE UDS @ 4'-O" O.C. ATTACHID TOP & BOTTOM 6 '- AC CEILING TILE CONT. MTL CASING BEAD TYP. 3 1 /2" - 25 GA. MTL. STUD @ 24" O.C. W/ 5/8" GYP. BD. ON EACH SIDE CONT, STUD CHANNEL - FASTEN TO DRIVEN @ 32" O.C. MAX. & 6"MAX.ENDS ENER (2) CONT. STRIPS DBL. FACE VINYL TAPE SCALE N. T. S. ®M.■MM®M■ ■ ■ NONE ■■ ONE ■ mom s■ ■ ME ■■ ■ ARCHITECTRO►NIX, INC 2030 N. TWTIN AMENM4 SUITE B SANTA AN& CA 92705 7W83&0702 REVISIONS ADDENDUM#1 4-20-99 All ideas, drawings, and specifications shown hereon are the property of Architectronix and shall not be used, copied, reproduced, or disclosed to any person, firm, or corporation, without the written consent of Architectronix. Any infringement will be subject to legal action. Contractors shall verify and be responsible for oil dimensions and conditions on the job and notify this office of any variations from dimensions and conditions shown herewith. Written dimensions take precedence over scaled dimensions. 4�� N M. ,q ,�� ..,,i `rr No. C4 253 (P AL •` ` .A DATE�.'LLJ OF C Z 2: L/ 0MWJ UJ CLM0imam Lw 0 U ..-J U Q -< 1< U ZU Imam mmi z rr�r U `�• err (=) U 04 Ci. cat cry L... DRAVift SCALE NOTED )OS NO. DATE RELEASE DATE CAD NAME SHEET NO-- A2 PARKING SIGNAGE 2. During periods of partial or restricted use of a H. STAIRWAYS J. FLOORS & LEVELS 4. Water closet compartments shall be equipped with a door 2. Grob bars at the side shall be at least 42" long with building or facility, the entrances used for primary that has an automatic -closing device, and shall have a the front end positioned 24" in front of the water access shall be accessible to and usable by persons with 1. Stairways shall hove handrails on each side, and every clear, unobstructed opening width of 32" when located at closet stool and with the back end positioned no more 12. Each parking space reserved for persons with disabilities. stairway required to be more than 88" in width shall be 1. In buildings and facilities, floors of a given story the end and 34" when located at the side with the door than 12" from the rear wall. Grob bars at the back shall disabilities shall be identified by a reflectorized sign Sec 1001.9.2 [3301(h)2], provided with not less than one intermediate handrail shall be a common level throughout, or shall be positioned at an angle of 90 degrees from its closed be not less than 36" long. permanently posted immediately adjacent to and visible for each 88" of required length. Intermediate handrails connected by pedestrian ramps, passenger elevators, or position. Sec 1115B.8,1 [3105A(b)W(i)], Fig 11B-1A, B, & C. from each stall or space, consisting of a profile view 3. Exit doors shall be openable from the inside without the shall be spaced approximately equally across the entire special access lifts. Sec 1115B.7.1.3 [3105A(b)3A(iii}j. Fig 1 1 B-1 A & B. of a wheelchair with occupant in white on dark blue use of a key or any special knowledge or effort. width of the stairway. Sec 1120B.1 [3105A(j)l], 3. Grab bars shah be securely attached 33" above and background. The sign shall not be smaller than 70 square Sec 1004.3 [3304(c)]. Sec 1006.9.1 [3306(i.1)1]. 5. When standard compartment doors are used, with a minimum parallel to the floor, except that where a tank -type inches in area and, when in a path of travel, shall be 2. Ground and floor surfaces along accessible routes and in 9" clearance for footrests underneath and a self -closing toilet is used which obstructs placement at 33", the posted at a minimum height of 80" from the bottom of the 4. Manually operated edge or surface -mounted flush bolts 2. Handrails shall be 34" to 39' above the nosing of the accessible rooms and spaces, including floors, walks, device, clearance at the strike edge as specified in grab bar may be as high as 36'. sign to the parking space finished grade. and surface bolts ore prohibited. When exit doors are treads, romps, stairs, ramps, sholl be stable, firm, Sec 1115B.8.1 3105A b 3C I Fig 11B-1A. and curb rams Section 1004.9.2.2 is not required. [ { } ('}], g Sec 1129B.5[3107A(c)]. Fi 1 1 B-18A, B, & C. used in pairs and approved automatic flush bolts are Sec 1006.9.2.1 [3306(i.1)2A]. Fig 11 B-35. and slip -resistant. Sec 1115B.7.1.3 [3105A(b)3A(iii)]. 9 4. The diameter or width of the gripping surfaces of a grab used, the door leaf having the automatic flush bolts Handrail and mounting device shall be designed Sec 1124B.1 [3105A(n)l]. 13. Signs to identify accessible parking spaces may be shall have no doorknob or surface -mounted hardware. The for 250 pounds p/ linear feet load 6. The inside and outside of the comportment door shall be bar shall en 1-1/4" to 1 ace. I or the shape shall provide unlatching of an leaf shall not require more than one , an equivalent gripping surface. If grub bars are mounted centered on the wall at the interior end of the parking 9 Y q 3. Changes in level up to 1/4' may be vertical and without equipped with a loop or U-shaped handle immediately 3. Handrails shall extend o minimum of 12 beyond the top adjacent to a wall, the space between the wall and the space at a minimum height of 36" from the parking space operation. edge treatment. below the latch. The latch shall be flip -over style, " nosing and 12" plus the tread width beyond the bottom grab bars shall be 1-1/2 . finished grade, ground or sidewalk. Sec 1004.3 [3304(c)]. Sec 1 124B.2 [3105A(n)2]. Fig 11 B-5E(c). sliding, or other hardware not requiring the user to nosing, or twist. Sec 1 1 158.8.2 [31 Q5A(b)3C(ii)]. Fig 11 B-1 C. Sec 1129B.5 [3107A(c)]. Sec 1006.9.2.2 [3306(i.1)2B]. Fig 11 B-35 & 37. grasp 5. Latching and locking doors that ore hand activated and 4. Changes in level between 1/4" and 1/2" shall be Sec 1115B.7.1.3 [3105A(b)3A(iii)]. 5. A grab bar and any wall or other surface adjacent to it 14. Van accessible parking spaces shall have an additional which are in a path of travel shall be operable with a 4. Where the extension of the handrail in the direction of accomplished by means of o romp no steeper than 1 shall be free of any sharp or abrasive elements. Edges sign stating "Van -Accessible' mounted below the symbol single effort by lever type hardware, panic bars, the stair run would create a hazard, the termination of vertical to 2 horizontal. 7. Except for door opening widths and door swings. a clear, shall have a minimum radius of 1/8". Y the extension shall be made either rounded or returned of accessibility. push-pull activating bars, or other hardware designed to Sec 1 124B.2 [3105A(n)2]. Fig 1 1 B-5E(d), unobstructed access not less than 44" sholl be provided Sec 1115B.8.4 [3105A(b)3C(iv)]. Sec 1129B.5 [3107A(c)], provide passage without requiring the ability to grasp to water closet compartments designed for use by persons smoothly to the float, wall, or post, Where the stairs the opening hardware. Locked exit doors shall operate as 5. If carpet or carpet tile is used on a ground or floor with disabilities and the space immediately in front of are continuous from landing to landing, the inner roil , P. DRINKING FOUNTAINS 15. An additional sign shall also be posted, in a above in egress direction. surface, it sholl be securely attached; have a firm a water closet compartment sholl be not less than 48' as Sec 1004.3.1 3304 c.1 shall be continuous and need not extend out into. the conspicuous place, at each entrance to off-street [ ( )] landing cushion, pod or backing or no cushion or pod; and have a measured at a right angle to compartment door in its 1. In new construction, where more than one drinking parking facilities, or immediately adjacent to and Sec 1006.9.2.4 [3306(i.1)2D]. Fig 11 B-37. level loop, textured loop, level cut pile, or level closed position. fountain or water cooler is provided on o floor, 50% of visible from each stall or space. The sign shall be not 6. Hand -activated door opening hardware shall be centered cut/uncut pile texture. The maximum pile height shall be Sec 1115B.7.1.3 [3105A(b)3A(iii)]. Fig 1 1 B-1 B. those provided shall comply with Plumbing Code Section less than 17" by 22" in size with lettering not less between 30" and 44" above the floor. 5. Ends shall be returned or terminate in newel posts or 1 /2". Exposed edges of carpet shall be fastened to floor 1507 and shall be on an accessible route. than 1" in height, which clearly and conspicuously Sec 1004.3.1 [3304(c.1)], safety terminals. Handrail shall not rotate within the fittings surfaces and have trim along the entire length of the 8. Where six or more stalls are provided within a multiple Sec 1 1 17B.1.1. states the following: Sec 1006.9.2.3 330E i.1 2C . Fig 11B-35 & 37. exposed edge. Carpet edge trim shall comply with Section accommodation toilet room, in addition to the standard [ ( ) ] 9 2. Drinking fountains shall be located completely within Sec 11298.5 [3107A(c)]. 7. Every doorway which is !ocated within an accessible path 1124B.2. accessible stall required above, at least one additional g P Y of travel shall be of a size as to permit the Sec 1124B.3 [3105A(n)3]. Fig 11 B-7B. stall shall be provided with a width of 36' with an alcoves or otherwise positioned so as not to encroach "Unauthorized vehicles parked in designated installation of a door not less than 3' in width and not outward swinging self -closing door and parallel grab into pedestrian ways. The alcove in which the water 6. The handgrip portion of handrails shall be not less than fountain is located shall be not less than 32" in width accessible spaces not displaying distinguishing less than 6'-8" in height. When installed, exit doors SANITARY FACILITIES (GENERAL) bars complying with Sections 11158.8.2 through 1-1/4' nor more than 1-1/2" in cross sectional dimension K. (r placards or license plates issued for persons with shall be capable of opening so that the clear width of � 11158.8.4. and 18" in depth• disabilities may be towed away at owners expense, the exit is not less than 32", measured between the face or the shape sholl provide an equivalent gripping Sec i 1156.7.1,4 [31 Q5A(b)3A{iv}]. Sec 1117B.1,2 [3105A(d)IB]. Fig 1113-3. surface. The handgrip portion of handrails shall have a 1. Sanitary facilities that serve buildings, Towed vehicles may be reclaimed of the door and the opposite stop. yfacilities or 3. Drinking fountains steal! be o minimum of 18 in depth smooth surface with no sharp corners, Any wall or other 9 P at_____________________ or by telephoning Sec 1115B.4.1, 1004.6, & 1Qfl4.6.5 [33Q4 (a}1 & (f)1]. portions of buildings or facilities that are required to and there shall be a clear and unobstructed knee space surface adjacent to the handrail shall be free of sharp P _________________� Fig 1 1 B-5B & 118-33, be accessible to persons with disabilities are required N. SANITARY FACILITY FIXTURES &ACCESSORIES g or abrasive elements. Edges shall have a minimum radius under the drinking fountain not less than 27" in height to be accessible, » Of 118r. Sec 1 115B.1 3105A b I . 1. The height of accessible water closets shall be a and 8 in depth,the depth measurement being taken from Note: Blank spaces are to be filled in with 8. Where a pair of doors is utilized, at least one of the Sec 1006.9.2.E [33fl6(i,1)2F]. Fig 11B-36. [ () j g the front edge ofthe fountain. appropriate information as a permanent doors shall provide a clear, unobstructed opening width minimum of 17" and a maximum of 19" measured to the top Sac root e of t e f Fig 11 B-3. part of the sign. of 32" with the leaf positioned at an angle of 90 2. Where separate facilities are provided for non -disabled of a maximum 2" high toilet seat, except that 3 seats 7. Handrails projecting from a wall shall have o space of persons of each sex, separate facilities shall be shod be degrees from its closed position, P P permitted only in alterations where the 4. There steall be toe clearance of 9" in height above the 1-1/2" between the wall and the handrail. Handrails may " 16. The surface of each accessible parking space or stall Sec 1004.6.2 [3304(f)3]. " provided for persons with disabilities of each sex also. existing fixture is less than 15 high. floor, and 17" in depth from the front edge of the be located in a recess if the recess is a maximum of 3 Where unisex facilities are provided far Sec i 502 1502 shall have a surface identification duplicating either P [ ]• fountain. deep and extends at least 18 above the top of the rail. non ed non -disabled persons, such unisex of the following schemes: 9. When an automatic door operator is utilized to operate a PP / P Sec 1507.1 [1507(a)]. Sec 11298.5 [3107A(c)]. Fig 116-18A, B, P p Sec 1006,9.2.5 [3308{i.i)2E], Fig 11B-36, facilities can be provided for persons with 2. A clear floors ace 30" b 48" shall be provided in & C. air of doors, at least one of the doors shall provide a P P P Y a, B outlining or painting the stall or ace in blue clear, unobstructed opening width of 32" with the door disabilities. front of a lavatory to allow a forward approach. Such 5. A side approach drinking fountain is not acceptable. Y 9 P 9 P 8. The upper approach and the lower tread of each stair Sec 11158.2 31fl5A b 1A . clear Haar s and outliningon the round in the stall or ace positioned at an angle of 90 degrees from its closed [ (} ] pace shall adjoin or overlap an accessible Sec 1507.1 [1507(a)]. 9 P shah be marked by a strip of clearly contrasting color in white or suitable contrasting color a profile position. „ route and shall extend into knee and toe space at least 2' and no more than 4 wide placed parallel #0 6. The drinking fountain bubbler shall be activated by a view depicting a wheelchair with occupant; Sec 1004.6.3 [3304(f)4]. 3. Where facilities are to be used solely by small underneath the lavatory. p g P and not more than 1 from the nose of the step or control which is easily operated by a handicapped children, the specific heights may be adjusted to meet Sec 1115B.9.1.1 [3105A(b)4A(i)]. Fig 1 1 B-1 B. or landing to alert the visually impaired. The strip shall person, such as ahand-operated level type control their accessibility needs. b. By outlining a profile view of a wheelchair with 10. For hinged doors, the opening width shall be measured be of material that is at least as slip resistant as the located within 6" of the front of the fountain, a push 9 P 9 Sec 11158.3 [3105A(b}1Bj. 3. Lavatories adjacent tad wall shall be mounted with a occupant in white on blue background. The profile with the door positioned at an angle of 90 degrees from other treads of the stair. minimum distance of 18" to the center line of the bar control along the front of the drinking fountain, view shall be located so that it is visible to a its closed position. Sec 1006.16.1 [3306(q)]. Fig 11 B-35. 4. Doorways leading to men's sanitary facilities shall be fixture. etc' traffic enforcement officer when a vehicle is Sec 1004.6.1 [3304(f)2]. Fig 11B-33(a). identified by an equilateral triangle 1/4" thick with Sec 1504.1 [1504(a)]. Fig 11B7-1A. Sec 1507.2 [1507(b)]. Fig 118-3. properly parked in the space and shall be 36" high 9. Where stairways occur outside a building, the upper edges 12" long and a vertex pointing upward. Women's by 3C wide. 11. There sholl be a level and clear floor or londin on approach and all treads shall be marked by a strip of " 7. The bubbler outlet orifice shall be located within fi' of 9 " sanitary facilities shall be identified by a circle 1 /4 4. Lavatories shall be mounted with the rim or counter each side of a door. The level area shall have a length clearly contrasting color at least 2 and no more than the front of the drinking fountain and shall be within 9 " thick and 12' in diameter, surface no higher than 34' above the finished floor and > - in the direction of door swingof at least 60" and the 4' wide and placed parallel to and not more than 1 from g 36' of the floor. The water stream from the bubbler Sec 1115B.5 [3105A(b)1D]. length opposite the direction of door swing of 49' as the nose of the step or landing to alert the visually with a clearance of at least 29" from the floor to the shall be substantially parallel to the front edge of the bottom of the apron with knee clearance under the front measured at right angles to the lane of the door in the impaired. The strip shall be of a material that is at drinking fountain. 9 9 P 5, Unisex sanitary faculties shall be identified by a lip extending o minimum of 30' in width and $" minimum Sec i 507.2 [1507(b}]. Fig 1 1 B-3, closed position. least as slip -resistant as the other treads of the circle 1 4" thick 12" in diameter, with a 1 4" thick Sec 1115B.4.2 & 1004.9.2.2 3304 i.1 28 . Fig 11 B-26. stair. A pointed strip shall be acceptable. / / depth at the top. Toe clearance shall be the same width [ ( ) ] g triangle superimposed on the circle and within the 12" and shall be a minimum of 9" high from the floor and a Sec 1006.16.1 [3306)]. Fig 1 18-35. (qdiameter, minimum of 17" deep from the front of thy' lavatory. Q. PUBLIC TELEPHONES 12. The width of the level area on the side to which the Sec 1115B.5 [3105A(b)1D]. Sec 1504.1 [1504(o)]. door swings sholl extend a minimum of 24" past the 1. If public telephones are provided, the shall be mode strike edge of the door for exterior doors and a minimum 10. All tread surfaces shall be slip -resistant. Treads shall P P P > Y 9 6. Geometric (circle & triangle) symbols on sanitary 5. Hot water and drain pipes accessible under lavatories accessible. of 1 past the strike edge €or interior doors. have smooth, rounded, or chamfered exposed edges, and no facility doors sh,Il be centered on the door at a height shall be insulated or otherwise covered. There shall be Sec 1115B.4.2 & 1004.9.2.3 3304 i.1 2C . Fig 1 18-26. abrupt edges at the nosing (lower front edge). Sec 1 1 178.2,1 [3i Q5A(d)2A]. [ ( ) ] 9 of 6C?' and their color and contrast shall be distinctly no spar or abrasive surfaces under lavatories. HANDICAPPED Sec 1006.16.2.1 & 1006.16.2.1.1 [3306(r)1]. Fig 11B-35. P different from the color and contrast of the door, Sec 1504,2 1504 b 2. A clear floor or " [ ()] ground space at least 30' by 48 that PARKING O N L 13. The floor or landing shod be not more than 1 /2" lower Sec 1115B.5 [3105A(b)1 D]. allows either d forward or parallel than the threshold of the doorway. 11. The nosing shall not project more than 1-1/2" post the p allel approach by a person 6. Where urinals are provided, at least one shall have a using a wheelchair shall be provided at telephones. face of the riser below. 9 P P Sec 1004.9.1 o [3304(i.1)1 ]. Fig 11 B-32. NOTE: See also Section 1117B.5.9 for additional clear floor space 30" by 48 in front of the urinal to Sec 1 117B.2.2 3105A d 2B . Fig 118-4. Sec 1006. 16,2.2 [3306(r)2]. Fig 11 B-35, [ () ] 9 signage requirements applicable to sanitary allow forward approach. E n 14. The space between two consecutive door openings in a facilities. 3 -O MIN. VAN Sec 11 158.9.4 3 i fl5A b 4D . vestibule, serving other than a required exit stairway, i 2. Open risers ore not permitted. [ () ] 3. Bases, enclosures and fixed seats shall not impede SQUARE ACCESSIBLE shall provide a minimum of 48" of clear i ace from an Sec 1006.16.3 [3306(r)3]. Fig 11B-35. approaches to telephones by people who use wheelchairs. P P Y L. SINGLE ACCOMMODATION SANITARY FACILITIES 7. Where one or more urinals ore provided, at least one Sec 1117B.2.5 [3105A(d)2E]. door opening into such vestibule when the door is » positioned at an angle of 90 degrees from its closed 13. Approved stairway identification signs shall be located with a rim projecting a minimum of 14 from the wall and at each floor level in all enclosed stairways in of a maximum of 17" above the floor shall be provided. 4, The highest operable part of the telephone shall be position. Doors in a series shall swing either in the Y 1. There shall be suffcient space in the toilet roam fora Sec 15fl3.1 1503 a ' PARKINS PARKING buildings four or more stories in height, two or more " [ ()] within 4b' of the floor if forward approached and 547 if same direction or away from the space between the chars. 9 g wheelchair measuring 30 wide by 48" long #o enter the SURFACE SPACE See Fig 9 Figures 11 B-30&31 for design alternatives. stories in height for DSA/AC requirements. The sign side approached. roam and permit the door to close. $. Controls for voter closet flush valves shall be mounted Sec 1004.9.2.4 [3304(i.1)2D]. shall identify the stairway, indicate whether there is Sec 1 1 158.7.2 [3105A(b)3B]. Sec 1 1 17B.2.6 [3105A(d)2F]. Fig 11 B-4. roof access, the floor level, and the upper and lower on the wide side of toilet areas. UNAUTHORIZED VEHICLES 15. The bottom 1 C of all doors except automatic and sliding Y 9 Sec 1502 1502 . terminus of the stairway, The sign shall upper located [ ] 5. Telephones mounted diagonally in a corner that require P 9 2. There shall be in the room a clear floor space of at NOT DISPLAYING shall have a smooth, uninterrupted surface to allow the approximately 5' above the floor landing in a position wheelchair users to reach diagonally shall have the DISTiNGUISHING PLACARDS P least 60 in diameter, or a T-shaped space complying with g, Water closet and urinal flush valve controls, and faucet OR LICENSE PLATES Boar to be opened b a wheelchair footrest without which is readily visible when the door is in the open or highest operable part no higher than 54" above the P Y Figures 11 B-12(a) or (b). No door shall encroach into and operating mechanism controls, shall be operable with floor. ISSUED FOR PHYSICALLY creatinga trap or hazardous condition. Where narrow closed position or as required by DSA/AC the sign shall HANDICAPPED PERSONS P " this space. one hand, shall not require tight grasping, pinching, or Sec 11 178.2.E 3105A d 2F . Fig11 B-4. MAY BE TOWED AWAY frame doors are used, a 10 high smooth panel shall be be located approximately 5' above the floor landing Sec 1 1 15B.7.2 3105A b 3B . Fig1 1 B-IA [ (} ] installed on the push side of the door, which will allow Y 1 [ () ] twisting of the wrist, and shall be mounted no more than AT OWNER'S EXPENSE. immediate) adjacent to the door on the strike side, 9 TOWED VEHICLES MAY the door to be opened by a wheelchair footrest without Signs shall comply with the requirements of UBC Std. No, 44" above the floor,3. The water closet shall be located in a space which 6. The card from the telephone to the handset shall be at P Sec 1502, 1503.2, & 1504.3 1502, 1503 b , & 1504 c BE RECLAMED AT. 10_2, [ () (} least 29" long. creating . trap or hazardous condition. provides a minimum 28' wide clear space from a fixture Sec 1117B.2.11 [3105A(d)2K]. Sec 1004.8.1 3304 i,3 Fig 118-29. Sec 1006.1E [3306(p)]. [ ( }] 9 or a minimum 32' wide clear space from a wall at one 10. The force required to activate water closet and urinal DR BY TELEPHONING: side. The other side shall provide 18" from the flush valve controls, and faucet and operating mechanism 7. Telephones shall have push-button controls where service 16. Recessed doormats shall be adequately anchored to centerline of the water closet to the wall. A minimum controls, shall be no greater than 5 IV. for such equipment is available. THIS APPLIES ONLY TD prevent interference with wheelchair traffic. SMOOTH SURFACE SMOOTH SURFACE 48" clear space shall be provided in front of the water Sec 1502, 1503.2, & 1504.3 [1502, 1503(b), & 1504(c)]. HANDICAPPED SPACES Sec 1001.9.3 [3301(h)3]. Fig 11 B-25. closet. Sec 1 17B.2.10 [3105A(d)2J]. Sec 1115B.7.2 [3105A(b)3B], Fig 118-1 A. 11. Self -closing faucet control valves are allowed if the 8. If telephone enclosures are provided, they shall comply 17, Maximum effort to operate doors shall not exceed 5 -.► faucet remains open for at least 10 seconds. with the following: pounds for exterior doors and 5 pounds for interior „ z 4. All doors, fixtures and controls shall be on an Sec 1504.3 1504 c 1 ll4 [ ()] Sec 1117B.2.7 [3105A(d)2G]. doors, such pull or push effort being applied at right a A4ii ii i f o accessible route with a minimum clear width of 36' angles to hinged doors and at the center lane of Imo' / SITE g 9 P m M I ISM except at doors. If a person in a wheelchair must make a 12. Mirrors shall be mounted with the bottom edge no higher a. For side approach telephones, the enclosure ENTRANCE sliding or folding doors. Compensating devices or _ _ turn around an obstruction, the minimum clear width of than 40" from the floor. overhang shall be no greater than 19" and the automatic door operators may be utilized to meet the CI the accessible route shall be as shown in Figure 118-5E. Sec 11158.9,1,2 [3105A(b)4A(ii)]• height of the lowest overhanging part shall be NOTE: above standards. When fire doors are required, the �,.. �( Sec 1115B.7.2 [3105A(b)3B]. maximum effort to operate the door may be increased #o equal to or greater than 27", GRID S H D W N FOR LAYOUT PURPOSE P Y 13. Where towel, sanitary napkins, waste receptacles, and �� n the maximum allowable b the appropriate administrative ' ` M. MULTIPLE ACCOMMODATION SANITARY FACILITIES Y P P Sec 11178.2.7.1 [3105A(d)2G(i)], Fig 11B-4(a), ONLY. D N E SQUARE EQUALS 3 X 3 �''>!- �- other similar dispensing and disposal fixtures are MINIMUM. authority, not to exceed 15 pounds. r provided, at least one of each type shall be located b, For forward approach telephones, if the enclosure Sec 1004.5.1 [3304(i.2)1]. 1. A clear space measured from the Door to a height of 27" with all operable parts, including coin slots, within overhang is greater than 12", the clear width of 3 above the floor, within the sanitary facility room, of 40" from the finished floor. the enclosure shall be 30" minimum; if the clear F. PEDESTRIAN GRADE SEPARATIONS sufficient size to inscribe a circle with a diameter not Sec 1115B.9.2 [3105A(b)4B]. width of the enclosure is less than 30", the height less than 60", or a clear space 56 by 63" in size, of the lowest overhanging part shall be equal to or shall be provided for wheelchair maneuvering. Doors 14. Toilet tissue dispensers shall be located on the wall „ other than the door to the accessible toilet compartment P greater than 27 , P within 12" of the front edge of the toilet seat and no Sec 11178.2,7.3 [3105A(d)2G{iii)]. Fig 11 B-4(c). 1. Pedestrian ramps on pedestrian grade separations shall !� I. CORRIDORS & AISLES in any position may encroach into this space by not more lower than 19" from the floor. Dispensers that control comply with the requirements of Section 1007 for romps. F_ 24 MI . CLEAR AT than 12'. delivery or that do not permit continuous paper flow C. Entrances to full -height enclosures shall be 301' Sec 1 128B [3106A(f)]. Z XTE R I O R DOOR'S Sec 1 1 15B.7.1.1 [3105A(b)3A(i)]. Fig 11 B-1 B. shall not be used. minimum. 1 1. Every corridor serving an occupant load of 10 or more Sec 1 115B.9.3 [3105A(b)4C]. Fig 1 1 B-1 A. Sec 11 178.2.7.2 [3105A(d)2G(ii)]. Fig 11 B-4(b). 2. Where pedestrian grade separations cross streets or » 2. A water closet fixture located in a compartment shall n shall not be less than 44 in width. , P other vehicular traffic ways, and where a street level 1 MI . CLEAR AT Sec 1005. e[3305(b)1.1].provide a minimum 28' wide clear space from a fixture or 15. Toilet room floors shall have a smooth hard, crossingcan reasonably and safe) be used b persons " d. Where telephone enclosures protrude into walls, Y Y Y P to TERIOR DOORS a minimum 32 wide clear space from a wall at one side non -absorbent surface such as Portland cement, concrete, halls, corridors or aisles, they shall comply with with disabilities, there sholl be provided conforming 2. Corridors servingant load of less than 10 shall of the water closet. The other side of the water closet ceramic the or other approved material which extends an occupant PP Section 1121 B. curb ramps and a usable pathway. > shall provide 18" from the centerline of the water ' Sec 1 128B [3106A(f)]. not be less than 36 in width. closet the wall, Grob bars shall not project more upward onto the walls at least 5' . Walls within water Sec 1117B.2.7.4 [3105A(d)2G(iv}]. Z Sec 1005.2 .1 [3305(b)1.1]. P 1 closet compartments and walls within 24" of the front Z -*A than 3" into these clear spaces. and sides of urinals shall be similarly finished to a 9. Telephones shall be equipped with a receiver that 3. Cross slopes of walking surfaces shall be the minimum - I 3. Corridors which are located on an accessible route and Sec 11158.7.1.2 [3105A(b)3A(ii)l. Fig 1 1 B-1 B. height of 48" and, except for structural elements, the possible and shall not exceed 1 /4' per foot. The slope I �.-- PROVIDE THIS g P generates a magnetic field in the area of the receiver of any appreciably warped walking surface shall not ADDITIONAL SPACE exceed 200' in length steall have a minimum clear width materials used in such walls shall be a type which is cap. If banks of public telephones are provided, at of 60 , have, at a central location, a 60 b 60' 3. A minimum 48 long clear space shall be provided in not adverse) affected b moisture, exceed 1 vertical in 12 horizontal in any direction. � I F DOOR 1 S E U I PED Y y Y least one in each bank and a total of at least 25% of j Q front of the water closet if the compartment has an end Sec 1115B.9.5 3105A b 5 . _ d WITH BOTH A LATCH minimum wheelchair turning space or passing alcove; [ (} ] the fatal number of public telephones, including closed Sec 11288 [3106A(#)], have, at a central location, an intervening cross or tee opening door (facing the water closet) and a minimum 60" AND A CLOSER. " g circuit telephones in a building or facility, shall be MilIon clears ace shall be provided in front of the water equipped with a volume control. Such telephones shall be corridor, a minimum of 48 in width; or, have, at d 9 P G. ENTRANCES & EXITS central location, on openable door. closet if the compartment has a door located at the side. Grab bars shall notproject more that 3" into O, GRAB BARS capable of a minimum of 12 dbA and a maximum of 18 dbA Sec 1005.2.2 [3305(b)2]. Fig 11 B-34, above normal. If an automatic reset is provided, 18 dbA these clear spaces. 1. Grab bars shall be located on each side, or on one side may be exceeded. Public telephones with volume control 1. All entrances and all exterior ground floor exit doors 4. Circulation aisles and pedestrian ways shall be sized Sec 1115B.7.1.2 [3105A(b)3A(ii)]. Fig 1 1 B-1 A&B. and the back of the accessible toilet stall or shall be hearing aid compatible and shall be identified to buildings and facilities shall be made accessible to according to functional requirements and in no case compartment. by a sign containing a depiction of a telephone handset persons with disabilities. shall be less than 36" in clear width. Sec 1115B.8.1 [3105A(b)3C(i)]. Fig 118-1A, B, & C. with radiating sound waves. Sec 11148.1.3 & 1001.9.1 [3301(h)1]. Sec 1105B.3.6.1 & 1110B.2.1 [3103A(c)2G(i)]. Sec 1117B.2.8 [3105A(d)2H]. INNEMENNNIN ■ME■ ONE ONE ON MININ■®i■ MONNOMMON /'RCHITECTRO►NIX, INC 2030 U TUSTIN AVENUE, SUITE & SANTA ANA, CA 9M 7I4183"702 A� REWSIONS All ideas, drawings, and specifications shown hereon are the property of Architectronix and shall not be used, copied, reproduced, or disclosed to any person, firm, or corporation, without the written consent of Architectronix. Any infringement will be subject to legal action. Contractors shall verify and be responsible for all dimensions and conditions on the job and notify this office of any variations from dimensions and conditions shown herewith. Written dimensions take precedence over scaled dimensions. ARC/, i 0. C0172 ATE OF CA�'���. ce U-i Z LLj 0 0 U Z "ItCie Z V U CLO y N DRAWft JM R SCALE NA E JOB NO. DATE; RELEASE DATE: CAD NAME 33303FAl SHEET NO.: 10i If o total of four or more public pay telephones are � � provided at the interior and exterior of o m�e' and � at |aoat one of the total is in on interior location, � M E3 then at |ouet one interior public text telephone ahnU Ell be provided. W See 1117B.2.9.1 [3105A(d)21(i)l. 11. Text telephones ohoU comply with the following: Sec 11178.2.9.2 [3105A(d)21(iAl o. Text telephones used with o pay telephone uhoU be permanently affixed within or adjacent to the 0 Fe-1 telephone enclosure. If on acoustic coupler is U used, the telephone cord shall be sufficiently long to allow connection of the text telephone and telephone receiver. / / Sec 1117B.2.9.2.1 [3105A(d)2|(i0ol CONTROLS, SWITCHES & OUTLETS b. Pay telephones designed to accommodate u portable text telephone mhd| be equipped with o shelf and on electrical outlet within or adjacent to the S. HAZARDS & PROTRUDING OBJECTS telephone enclosure. The telephone handset ohoU be capable of accommodating o text telephone and shall 1. Abrupt changes in |ove|, except between o walk or have 6' minimum vertical clearance in the area sidewalk and on adjacent street or driveway, exceeding where the text telephone is to be placed. 4^ in o vertical dimooaion, such as at planters or Sec 11178.2.9.2'2 [3105A(d)21(ii)bl. fountains located in or adjacent to walks, sidewalks, or other pedestrian ways, shall be identified by warning C. Equivalent facilitation may be substituted for the curbs projecting at least 6' in height above the *o\k or above requirements as described in Section a|dowo|k surface to worn the blind of o potential drop 1 1 17B.2.y.2'J. off. See 1117B.2.9'2.3 [3105A/d\0(ii)cl. Sec 1024.1 [3325(o)l d. Text telephones ohoU be identified by the 2. When o guardrail or handrail is provided, no warning international TDD symbol (see Figure 118-14). If u curb is required when o guideroi| is provided centered facility has o public text telephone, directional 3" ± 1~ above the surface of the walk or s\dewo>k, the signogo indicating the location of the nearest such walk is 5 percent or |eao gradient, or no adjacent telephone mhoU be placed adjacent to all banks of hazard exists. telephones that do not contain o text telephone. Sec 1024.1 [3325(o)]. Fig 11B-27(b). Such directional aiynoge shall include the international TDD symbol. If o facility has no 3. Objects projecting from wo|ie with their leading edges banks of telephones, the directional aignoge mho|| between 27" and 8O~ above the finished floor aho|| be provided at the entrance or in o building protrude no more than 4° into wo|ko, ho||a, corridors, directory. - passageways, or aisles. Sec 1117B.2.9.3 [3105A/d\21(iii)l See 1121 8.1 [3105A(k) 1]. Fig 118-7A' 12' If telephone books are provided, they shall be located 4. Objects mounted with their leading edges at or below 27^ within 48° of the floor if forward approached and within above the finished floor may protrude any amount into 54~ if side approached. eo|ka, ho|la' corridors, passageways or oia|am. Sec 1117B.2.12 [3105A/d\2L]. Sec 1121B.1 [3105A(k)1]. Fig 11B-7A. 5. Free-stonding objects mounted on posts or pylons may overhung 12, nnoxinnunn from 27^ to 80^ above the ground or finished floor. See 1121B.1 [3105A(k)1l. S. Protruding objects ahoH not reduce the clear width of on accessible route or maneuvering space. Sec 1121B.1 [3105A/k\1]. 7. YYolhu^ ho}|n, corridors, poaoogewoyu' oio|eo or other Li circulation apouoo oho|| have 8O" minimum clear head [ room. See 1121 B.1 [3105A(k)2]. Fig 118-74. 8. Any obstruction that overhangs o pedeutriinn way mho|| be o minimum of 80^ above the walking surface as measured from the bottom of the obstruction. -�--- See 1024.2 F3325(b)|. Fig 118-28. MIN Q. Where o guy support is used poro||e| to o path of trove|, inoluding, but not limited to, sidewalks, o guy brace, sidewalk guy or similar device aho|| be used to prevent on overhanging, obstruction as defined. Sec 1024.2 [3325(b)l. 10. If o walk crosses or adjoins o vehicular way, and the walking surfaces are not separated by ourbm, roi|ings, or other elements between the pedestrian oraoo and vehicular areas, the boundary between the areas shall be defined by o continuous detectable warning which is 36° wide, complying with Section 1024.3 . w� See 1024.5 [3�25(e)l. - '' *HEIGHT TO HIGHEST OPERABLE PART WHICH US ESSENTIAL TO BASIC OPERATION OF THE TELEPHONE. R. CONTROLS & OPERATING MECHANISMS NJ 1. Controls and operating mechanisms required to be' accessible by Section 1D1.171-1U ohoH comply with the � T. ������ /\�k?�AN{�� �� REACH RANGES ALLOWANCE naqu�eme�� of Section 11178.6' ' See 1117B.8.1 [3105A/\|]. 1. The minimum clear floor or ground space required to 2. Clear floor space complying with Section 1118B.4 that occunnnnndote o single, stationary wheelchair and occupant allows o forward or ponzUm| approach by o person using is JCr by 48". (The minimum floor or ground space shall o wheelchair mho|| be provided at oontrob, dispensers, be increased to 427 by 487' when such space is receptacles, and other operable mquipnoent, perpendicular to on adjacent aeoting space). The minimum See 11178.6.2 [3105A(f)2]. clear floor or ground space for wheelchairs may be positioned for forward or poro||a| approach to on J. The highest operable port o/ all cnntrn|s, dispensers, object. Clear floor or ground space for wheelchairs may receptacles, and other operable equipment aho|| be be port of the knee space required under some placed within 48" of the floor but not lower than 15" if See 1117B.2.3 & 11188.4'1 [3105A(d)2C fk 3105A(h)4A]. forward approached and within S4" but not lower than 8^ if side approached. 2. One full unobstructed side of the clear floor or ground See 11178.6.3 [3105A(f)3]. space for o wheelchair oho(| adjoin or overlap on accessible route or adjoin another wheelchair clear 4. Controls and operating mechanisms aho|| be operable with floor apooa. If o clear floor or ground ap000 for o one hand and oho|| not require tight grasping, pinching, wheelchair is |000iad in on alcove or otherwise confined or twisting of the what. The force required to activate on all or port of three sides, additional maneuvering controls ohoU be no greater than 5 pounds of force. clearances shall be provided. See 1117B.6'4 /b 1507.2o [3105A/f\4]. See 1117B,2.4 & 11188'4.2 [3105A(d)2D & 3105A(h)48l.Fig 5. Faucet controls and operating mechanisms for kitchen sinks ohoU be operable with one hand and ohoU not 3. The space required for o wheelchair to make o 180 degree require gnooning, pinching, or twisting of the wMst' turn is o clear space of 6U^ diameter or o T-shaped The force required to active faucet controls and space. operating noenhonimnoa for kitchen sinks nho|} be no Sec 11188'3 [3105A(h)3]' Fig 118-12(o) &c (b). greater than 5 p|t Lever -operated, push -type, and electronically controlled nneohoniarna are examples of 4. The minimum clear width required for o wheelchair to acceptable designs. Self -closing vo{voa are allowed if turn around on obstruction aho|| be 36" where the the faucet remains open for at |oomt 10 seconds. obstruction is 4Y^ or more in length and 42, and 4E7 See 1508 [1508]. where the obstruction is |ooa than 48" in length. Fig 11B-5E, 6. Vending machines shall be installed in compliance with Section 1117B'6 through 11178.6.4. 5. The minimum clear width for single wheelchair passage See 1126B [3105A(p)l' oho|| be 327 at o point (24^ rnoxirnurn length) and 36" continuously. Sec 1118B.1 [3105A(h)1]' Fig 118-10. 0. The minimum width for two wheelchairs to poyo is 50~. 7' If the clear floor space only o||owa forward approach to on object, the maximum forward reach allowed ehoU be 49'. 3mm Figure 118-5C(a). The minimum low forward reach is 15 ~. If the high forward reach is over on obstruction, reach and clearances shall be as shown in Figure 1 1B-5C/b\. Bac 1118B.5 [3185A(h)4C]. O. If the clear floor space o|iowo parallel approach by o person in o wheelchair, the maximum high side reach allowed ohoU be 54~ and the low side reach aho|| be no |eam than 9^ above the floor as shown in Figures 11B-5D(o) 8c /b\. If the side reach is over and obstruction, the reach and deoronooa shall be as shown in Figure l 1B-5D(u). See 1118B.6 [3105A(h)4D]. U. EMPLOYEE VV(]RK AREAS & WORK STATIONS 1' Specific work stationa, with the exception ofwork stations in soles facilities, oheckatondo' ticket booths, and other work stations with specific requirements contained in other portions of the regulations, need only nnrnp|y with aisle width and floors and levels, and entry -ways aho|| be 32 ^ in clear width. Sec 1123B.2 [3105A(rn)2]. 2. Employee work areas oho|| be accessible by nneono of o 36" minimum aisle and o 32° minimum clear opening door width. See 1185B.3.2.3, 1105B.3.3.2.8c 11088'5 [3103A(c)2B(iii). 3103A(c)2D/J\` & 3103A(e)4l' 3' Employee areas uhcd| conform to all requirements of the Division of the State Architect/Access Compliance Section in the California Building Code, Plumbing Code, and Beothooi Code. V. FIXED OR BUILT-IN SEATING, TABLES, & COUNTERS l' Where fixed or built-in seodng, tables, or counters are provided for the public, and in general employee nraoa, 5%, but never |emm than 1 must be oucessib}e, as required in Section 1122B' See 1122B.1 [3105A(1)1]' 2. The tops of tables and counters shall be 28~ to 34~ from the floor or ground. Sec 11228.4 [3105AA\4]. 3. If seating for people in wheelchairs is provided at fixed tables or uountera, knee apoc*e at least 27^ high. 30~ wide` and 19° deep mho|| be provided. Sec 1122B.3 [3105AA\3]. Fig 11B-13. 4' If sooting spaces for people in wheelchairs are provided at fixed bob|as or coun(era, clear floor space complying with Section 11188'4 aho|| be provided. Such clear floor space yho|( not overlap knee space by more than 19~. Sac 1122B.2 [3105A(1)2]. Fig 116-13. 5' Where o single counter cnndo)ne more than one transaction station, such as (but not limited to) o bank counter with multiple teller windows or o retail ao|ea counter with multiple ooyh register stations, at least 5%, but never less than 1, of each type of station oho|| be located at o section of counter that is at least 36" long and no more than 28° to 347 high. W. SIGNS & IDENTIFICATION 1' The International Symbol of Accessibility shall consist of o white figure on o blue background. The blue ohoU be equal to Color No. 15090 in Federal Standard 590b. 3on 1117B.5.1.2 [3105A(e)2] 2. Letters and numbers on signs ahoU have o width -to -height ratio of between 3:5 and 1:1 and o stroke width -to -height ratio between 1:5 and 1:1 O. Sec 11117B.5.3 [3185A(e)4]. 3. Characters and numbers on signs uhoU be abed according to the viewing distance from which they are to be read. The minimum height is measured using on upper case X. Lower case characters are permitted.Fnr signs suspended or projected above the finish floor to'6ompUonce with Section 1121B, the minimum character height aho|| be 3". Sec 11178.5.4 |3105A(e)5l' 4. Characters and symbols ehoU contrast with their background, either light characters on o dark background or dark characters on o light background. See 1117B.5.5 [3105A(e)6]. 5. When nziood characters or symbols are used, they shall conform to the following: Sec 1117B.5.6 [3105A(e)7]. o. Letters and numbers on signs oho!| be raised 1/32~ minimum and aho|| be sons -serif uppercase characters accompanied by Grade 2 Braille. See 1117B.5.6.1 [3105A/e\7A], b. Raised characters or symbols uho|| be o minimum of 5/8^ high. See 1117B.5.6.2 [3105A/o\7B]. C. Pictono| symbol signs (pictograms) ahoU be 0000rnponimd by the equivalent verbal description placed directly below the piotognonn. The border dimension of the pictogrorn shall he o minimum of G" in height' 6. Contracted Grade 2 BroU|a ahoU be used wherever BnoU|e oynnho|a are specifically required in other portions of these regu|otiona. Dots ohoU be 1/1Or on centers in each uoU with 2/10~ space between cells. Dots aho|| be raised o rninirnurn of 1/4D" above the background. See 11178.5.2 [3105A/a\3]. 7. All building entrances that ore accessible to and usable by persons with dioobUiUma and at every major junction along or leading to on accessible route of travel shall be identified with o sign displaying the International Symbol of Accessibility and with additional directional signs, as required, to be visible to persons along approaching pedestrian ways. 8. When pannonerd identification is provided for rooms and opocea, raised letters ohoU be provided and mhoU be accompanied by Braille in conformance with Sections 11178.5.8through 1117B,5.6.3. Signs aho(| be installed on the wo|| ocjooant to the latch aide of the door. VVhoro there is no wo|{ space on the latch sido, including at double |aof doors, signs ahoU be placed on the nearest adjacent woU, preferably on the right. Mounting height oho\| be 6Cy above the finished floor to the centerline of the sign. Mounting location oho|| be determined so that o person may approach within 3° of aignoge without encountering protruding objects or standing within the owing of o door. Sec 11178.5.9 [3105A(e)10]. Q. Pole supported pedestrian traffic control buttons ohoU be identified with color coding consisting of o textured horizontal yellow bond 2" in width encircling the pole, and o 1" wide dodv border bond above and below this yellow bond. Color coding should be placed immediately above the control button. Control buttons uho|| be located no higher than 48^ above the surface adjacent to the pole. SS. ELECTRICAL 1. The center of electrical and communication system receptacle outlets ohoU be installed not less than 15 above the floor or working o|otfunn. Sec 1117B.6.3 [3105A(f)31 8c 210-7/g\, 2. The center of the grip of the operating handle of controls or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, opp|ionooa, or coo|ing, heating, and ventilating equipment sho|| not be more than 48" above the floor or working platform. See 580-8/c\. 3. The center of fire o|orrn initiating devices (boxes) aho|| be located 48" above the level of the floor, working p|otforrn, ground surface, or sidewalk. Sec 75O-9. NM OM Moi 0 omm M ENNOMMENE ARCHITECTRONM I INC All ideas, drawings, and specificotions shown hereon are the property of Architectronix and shall not be used, copied, reproduced, or disclosed to any person, firm, or corporation, without the written consent of Architectronix. Any infringement will be subject to legal action. Contractors shall verify and be responsible for all dimensions and conditions on the job and notify this office of any variations from dimensions and conditions shown herewith. Written dimensions take precedence over scaled dimensions. M. ce LU LLj 0 MR< Wawa 0 C) U Z U U Z CN LO SCALE' am DATE RELEASE DATE CAD NAME 33303FA.2 SHEET NO - I FA4,2 Im m�