Loading...
HomeMy WebLinkAbout10149509.pdf.® I nli PROPERTY LINE ^� EXISTING GRASS COVER AREA t C4 41 17'-6" 29'-611 91 41 (E.)BED RM. (E.)MASTER BED RM. NEW FAMILY RM. 490 sp. ft. ao CV 020 z ol z (E.)BED RM, (E.)KITCHEN W.H. (E.)LIVING RM. W. 00 D. 00 EXISTING (E,}GARRAGE DWELLING 1222 sq. ft. N 367 sq. ft. w w w w w w w w w W w w w w w w w w w w w w w w w w w w w w w w w w 17'-11" w w w '• w w w 29t-1,t w w w w w w w w w w w w w w w w w w y w w w W w w w w W w w w w w W w w w W w w w w w w w w w w w w w (E.)CONCRETE GRASS' DRIVE WAY wwwwwwwwwwwEXISTING w w w w w COVER AREA w wwwwwwwwww w w w w w N 483 sq, ft. w w w w w w w w w w w w w w w 41 w w w w w w w w w w w w w w w w W w w w w w w w w w w w w w W w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w u. ... Wa aL w w fi �.._,te...— w w �• Ali w _ -..y,c.__ PRnPFRTY I INF __�L SITE PLAN 1. ALL CONCRETE TO BC @MIN. 2,500 PSI @ 28 DAYS. USE TYPE V CEMENT, REINFORCING STEEL GRADE 4.0 2. ALL LUMBER TO BC DOUGLASS FIR, CONSTRUCTION GRADE It 2 OR BETTER UNLESS NOTED OTHERWISE. 3. ALL WINDOWS & DOORS TO BE CERTIFIED AND WEATHERS STRIPPED. ALL PENETRATION & SILLS TO BE CAULEK AND SEALED. 4 WALL INSULATION TO BE R-13 (TYP), CEILING INSULATION TO BE R-30 (TYP). 5. HEATING FROM NEW, RELOCATED FAU. 6. PROVIDE NEW BATTERY SMOKE DETECTORS W/ BACKUP BATTERY @ ALL EXISTING BEDROOMS, HALLS & HALLS LEADING TO BEDROOMS. PROVIDE 110V SMOKE DETECTORS W/ BACKUP BATTERY @ ALL NEW BEDROOMS & NEW HALLS LEADING TO BEDROOMS. 7. PROVIDE MIN. 22"X30" ATTIC ACCESS. 8. ALL PLUMBING WALLS TO BE 2X6. 9. PROVIDE MIN. ONE FLUBRESCENT LIGHT AT EACH BATHROOM. 10, SHOWER WALLS SHALL BE OF APPROVED NON -ABSORBENT. WATERPROOF MATERIAL TO A MIN. HEIGHT OF 6' ABOVE THE FLOOR, WAINSCOT SHALL EXTEND A FULL 4" BEYOND THE FACE OF THE SHOWER PAN. 11. NEW ASPHALT SHINGLE ROOF (MIN. CLASS "A") ROOF SHEATING: 1/2" OSB PLYWOOD PI 32/16 6,612. SLOPE 3/12 (TYP), OVERHANG 12" (TYP) TO MATCH EXISTING. 12, ALL EXISTING CONDITIONS, DIMENSIONS, SET BACK, SLOPES. & NEW DESIGN TO VERIFIED ON SITE BY CONTRACTORS PRIOR TO THE START OF SONSTRUCTION. 13. ALL WORK TO COMPLY WITH CBC 2001, CMC 2001, CEC 2001 AND STANDARDS & REQUIREMENTS FOR RESIDENTIAL AS ADOPTED BY CITY OF SANTA ANA UBC 97, UMC, NEC 96 (t.)bIUt WALK 14. PROVIDE WATER-RESISTANT GYPSUM BACKING BOARD AS A BASE FOR TILE OR WALL PANELS FOR TUB OR SHOWER ENCLOSURE OR WATER CLOSET COMPARTMENT WALLS. SEC.2512 15. SHOWERS SHALL BE FINISHED 70" ABOVE DRAIN WITH MATERIALS NAT ADVERSELY AFFECTED BY MOSITURE. SPECIFY MATERIALS. CLARIFY. SEC. 807.1.3, AND 2512. ANTI -SCALDING SHOWER AND TUB -SHOWER VALVES REQUIRED. 16. PROVIDE TEMPERED GLASS IN THE FOLLOWING HAZARDOUS LOCATIONS PER SEC. 2406.4: GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SWINGING DOORS, OTHER THAN WARDROBE DOORS. GLAZING IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLZING IS WITHIN A 24' ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE WALKING SURFACE. SAFELY GLAZING IS REQUIRED AT WARDROBE DOOR. SEC. 2406.5. 17. PLYWOOD COVERING THE EXTERIOR OF OUTSIDE WALLS SHALL BE EXTERIOR GRADE. CLARIFY. SEC. 2310.3 18. FIRE BLOCKING, VERTICAL OR HORIZONTAL, SHALL CONFORM TO SEC, 708.2, CLARIFY. 19. WHERE TOP PLATES OR SOLE PLATES ARE CUT FOR PIPES, A METAL TIE MINMUM 0.058" THICK AND V-1/2" WIDE SHALL BE FASTENED TO EACH PLATE ACROSS AND TO EACH SIDE OF THE OPENING WITH NOT LESS THAN 6-160 NAILS. CLARIFY. SEC. 2320.11.7. 20, THE BUILDING COMPLIES WITH THE REQUIREMENT OF TITLE 24, PART 6, SIGNED BY THE DESIGNER OR OWNER OF THE BUILDING AND BY THE DOCUMENTATION AUTHOR. 2210 S. GLENABOR ST. SANTA ANA, CA 92704 PROJECT LOCATION W. Warner Ave W. Pendleton Ave M cn v o a� ti Cb C7 0 cry W. Warner Ave C/ i,VICINITY PLAN 7 L STRUCTURAL A CC CCEPTED FOR C S TIIR T N ATE P i i 1T S A RE7 R E QUIRE D FOR ELECTRICAL, Pt UAGING 81 KAIECHANICAL PLANS TWS t t x 11 t (1= t$ ICE ke, t an the I ob &1411 U11188 suid it i urilatrItI11 to vake any Qr1;OB r City Of Santa Ana, iten p6rmlsslon from the The acceptance of tlt �1 s� (t1c t1I SAL NOT be hold to permftnor be at, approval Of the Y101ation of any 1' V8-1 ns of ANY Civi Ordinance o ate Law. f _ Accepted yw CITY OF SANTA ANA 21, MAINTENANCE INFORMATION. THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED DEVICE THATA REQUIRE ROUTINE MAINTENANCE FOR EFFICTIENT OPERATION,. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING , BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAIBLE TO THE ENFORCEMENT AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE PLANS AND SPECIFICATIONS DESCRIBED IN SECTION 10-103(A)2.A AND FOR WHICH THE BUILDING PERMIT WAS ISSUED AND CONFORMS WITH THE REQUIREMENTS OF PART 6. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED R-VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WIEGHT PER SQUARE FOOT CONSSITENT WITH THE MANUFACTURER'S LABELLED INSTALLED DISIGN DENSITY FOR THE DESIRED R-VALUE. 22. APPLY 8" DRY WALL TYPE 'X' TO ROOF SHEETING ACCORDING TO CODE. 23. USE SWEEP CREED BASE W/2" BELOW F.F. PEFLMiTTYPE,I LL � .,0 MECH GRADING 0C. RO C E EDITION-4 FLOOD ZONE — FLOOD ZONE CERTIF. Q'D YES ( 0 GENERALi , ii' PLAN,FOUNDATIONPLAN & SECTION ELEVATION ROOF PLAN,FRAMINGPLAN & DETAILS A5: TITLE 24 DETAILDRAWING SYMBOLS A DETAIL NUMBER SHEET NUMBER SECTION REFERENCE A SECTION NUMBER 41 SHEET NUMBER SINGLE POLE SWITCH DOUBLE POLE SWITCH A.F. ARCH -FAULT CIRCUIT INTERRUPTER � GROUND FAULT INTERUTER RECEPTACLE 110V DUPLEX CONV, OUTLET E CEILING LIGHTS ® 5 AIR CHANGES PER HOUR ELE ELECTRICAL PANEL sD SMOKE DETECTOR 9BATTERY OPERATED) @ EXISTING COSD NEW SMOKE DETECTOR W/HARD-WIRED BACKUP BATTERY EXISTING WALL TO REMAIN �■ WALL TO BE FILLED NEW WALL INDICATES SHEAR WALL TYPE AND LOCATION. SCOPE OF WORK OWNER: SANTUCCI RESIDENCE ADDED NEW FAMILY ROOM 490 sq. ft. LOT SIZE: 6090 sq. ft. ADDRESS: EXISTING RESIDENCE: 1222 sq. ft. 2210 S. GLENARBOR EXISTING GARAGE: 367 sq. ft. SANTA ANA, CA.92704 EXISTING DRIVE WAY: 483 sq. ft, NEW LIVING AREA: 1222 sq. ft. + 490 sq. ft.=1712 sq.ft, TEL: (714) 546-4472 LOT COVERAGE:(INC. GARAGE) 2079 / 6090 = 34 % FAX:, qqtwy @t DESIGN: LEGAL DESCRIPTION: TONY VO PARCEL NO: 408-232-26.:.. TRACK: 2260 r... —~� 13075 MAGNOLIA ST LOT: $7 t GARDEN GROVE, CA 92844 ZONE: R1 .wnx TEL: (714) 925-3145 `=... FAX; O 714 637-4188 LEGAL JURISDICTION; CITY OF SANTA ANA, CALIFORNIA 66 7 APPLICABLE CODES: 2001 FOR ALL BELOW CALIFORNIA BUILDING CODE CALIFORNIA MECHANICAL CODE CALIFORNIA PLUMBING CODE CALIFORNIA FIRE CODE CALIFORNIA ELECTRICAL CODE CALIFORNIA ENERGY CODE REVISION: DATE: A 5/23/05 DRAFTING SERVICE 13075 MAGNOLIA ST. GARDEN GROVE, CA 92844 TEL: (714) 925-3145 FAX: (714) 637-4188 SANAN SANTUCCI ROOM ADDITION 2210 S. GLENARBOR ST. SATA ANA I CA 92704 ALL DIMENSION, DESIGNS, SPECIFICATIONS REPRESENTED HEREIN ARE THE ORIGINAL AND UNPUBLISHED PROPERTY OF DRAGON CONSTRUCTION INC. AND SHALL NOT BE REPRODUCED, DISCLOSED OR USED BY OTHERS WITHOUT PRIOR WRITTEN CONSENT OF DRAGON CONSTRUCTION INC. VIEWING THESE CONDITIONS CONSTITUTES ACCEPTANCE OF THESE CONDITIONS. ALL RIGHTS RESERVED. DRAWN BY: Tony Vo DATE: 05-16-05 CHECK BY: DATE: FILE NAME: SHEET TITLE: General Notes, Site Plan, SHEET NO.: 1 OF 5 SHEETS 17'-6" 29'-6" �pFLOOR PLAN EXISTING ROOF % EXI5TING ROOF (E.)MASTER BED RM. I I (E.)BED RM. 60 3' OF THE PROPERTY LINE MUST BE ONE HOUR RATED CONSTRUCTION WITH 2 A4 TYPICAL RADIANT BARRIER 4 FOR T-24 ALL NEW ROOF AREA5 A3 A4 12 2X8 CJ (§ I G" O.C. R`) PER PLAN EXI5TING WALL NEW FAMILY RM. 2 A3 NEW CONCRETE FLOOR r 17'-6" EXISTING SECTION NEW SECTION SECTION A -A SCAL.E:1 J4"=1'-0" 4XG HDR K.13 1 A3 A4 r 1 A3 17'-6" A5PHALT COMP051TION ROOFING "CLA55 B" MIN, OVER 2-15 # FELT MIN. TYP. FOUNDATION PLAN SCALE: IJ4 =1-0 2 X 8 RIDGE 2x BLOCr\ING 2XG RR. 2 I G" O.C. 3 ROOF A4 FLA5HING / 2X8 CJ @ I G" O.C. J \ PER PLAN 6 (N.) A4 bo NEW FAMILY RM. (N.) PANTRY BATH. (E.) GARAGE 2 NEW CONCRETE A3 FLOOR I r r J 3 3 ROOM ADDITION EXISTING DWELLING A3 A3 SECTION V-B i SCAL.E:1 J4"=1'-0" 01 0 41" REVISIQN: DATE: A 5/23/05 DRAFTING SERVICE 13075 MAGNOLIA ST. GARDEN GROVE, CA 92844 TEL: (714) 925-3145 FAX: (714) 637-4188 SANAN SANTUCCI ROOM ADDITION 2210 S. GLENARBOR ST. SATA ANA ! CA 92704 ALL DIMENSION, DESIGNS, SPECIFICATIONS REPRESENTED HEREIN ARE THE ORIGINAL AND UNPUBLISHED PROPERTY OF DRAGON CONSTRUCTION INC. AND SHALL NOT BE REPRODUCED, DISCLOSED OR USED BY OTHERS WITHOUT PRIOR WRITTEN CONSENT OF DRAGON CONSTRUCTION INC. VIEWING THESE CONDITIONS CONSTITUTES ACCEPTANCE OF THESE CONDITIONS. ALL RIGHTS RESERVED. DRAWN BY: Tony Vo DATE: 05-16-05 CHECK BY: DATE: FILE NAME: SHEET TITLE: Floor Plan, Foundation plan, section, SHEET NO.: 2 OF 5 SHEETS A...2 (N) HALF ROUND ROOF VENT 24- DIA. EXISTING ROOF 60 M ic_ 04 EAST ELEVATION SCALE: 1/4"=11'-O" (E) HALF ROUND ROOF VENT 24- DIA. (E.) SL. WINDOW (E)STUCCO (E) HALF ROUND ROOF VENT 24- DIA. \_(E) SL. WINDOW (E) HALF ROUND ROOF VENT 24- DIA. (N) HALF ROUND ROOF VENT 24- DIA. (N) ASPHALT COMPOSITION ROOFING 'CLASS A' MIN. EXISTING ROOF — NEW CRICKET MIN. SLOPE 1/4" PER FT. OVER 2-15 �FELT MIN. TYP. (E) HALF ROUND ROOF VENT 24- DIA, EXISTING ROOF TO MATCH THE EXISTING 3' SETBACK FROM PROPERTY LINE F T 12 T NOTE: 12" max. ANY PORTION OF EAVE THAT IS WITHIN 3' OF THE PROPERTY LINE MUST BE ONE HOUR RATED CONSTRUCTION WITH NO OPENING. / ,/F/\ (N.) TEMPERED 7 GLASS SLO. DO (E) SL. WINDOW (E) SL. WINDOW (E)STUCCO EXISTING 3/4 EXISTING DWELLING ROOM ADDITION \—(N.) W/P NEW STUCCO FINISH TO MATCH EXISTING HOSE BIBB lop, Alk G.F.I. WEST ELEVATION SCALE: 1 /4"=1'-0" (N) ASPHALT COMPOSITION ROOFING "CLASS A" MIN. OVER 2-151FELT MIN TYP TO MATCH E EXISTING HALF ROUND ROOF VENT 24" DIA. GAUGE #26 METAL ROOF 18" W. GAUGE TO WALL FLASHING /-#25 VALLEY FLASHING EXISTING ROOF /—(N) HALF ROUND ROOF VENT 24" DIA, NEW CRICKET MIN, SLOPE 1/4 PER FT, --(N) VINYL SL. WINDOW (0 (N) VINYL SL. WINDOW NEW STUCCO FINISH TO MATCH EXISTING 16 DIA. LET IN BRACEROOM ADDITION EXISTING DWELLING IF SOUTH ELEVATION SCALE: 1 /4"=11'-0" NORTH ELEVATION SCALE: 1 /4"=11'-0" (N) HALF ROUND ROOF VENT 24" DIA. 7g] (E.) SL. WINDOW EXISTING ROOF (E.) SL. WINDOW (E)STUCCO (y) d NOTE: BORED HOLES NOT PERMITTED IN MORE THAN TWO CONSECUTIVE DOUBLE STUDS 1. NOTCH DEPTH & BORED HOLD SEE TABLE BELOW. 2. STUD PLASTER 0/ HEAVY GAUGE 3. SILL PLATE METAL LATCH 0/ MOISTURE 4. HOLE EDGE DISTANCE 5/8" BARRIER (O/PLYWOOD MIN. WHRER OCCURS) 1/2" DRY WALL TREATED SILL BOTTOM PLATE W1 5/8" X 12" L. 2X4 STUD @ 16" D.C. MIN. W ANCHOR BOLT W/ 2" X 2" X 3/16 WASHER 7/8" STUCCO 7" EMBEIDED INTO CONCRETE 32" O.C. R-13 BATT INSULATION & 12" FROM ENDS 3 1/2" THK, CONCRETE SLAB W/ 26 G. GALV. 6X641 0X#1 0 WIRE MESH 0/ 2" METAL SAND WEEP SCREED " 777-7. . I 4 z C14 4d 4 #4 REBAR CONT. 3" FROM TOP & BOTTOM (Typ.) 12" STUD NOTCHING/BORING LIMITS 5 EXT. BEARING FOOTING N.T.S. N.T.S. BORED HOLES STUD SIZE XT E IR 1, 'OR BEARINGBEARING WALLS NON - WALLS 2x4 1 7/16" 2 1/8- 2x6 2 3/16- 3 5/16- 1 2-20 1 2 1/8" 2 1/8" 2 5/16" 3" MAX. 1/2 DEP NOTCH DEPTH T,, SIZE OR & EXTERIOR NG , BEARING WALLS NON- BEARING WALLS 2x4 7/8' 1 7/16- 2x6 1 3/8" 2 3/16" 1- NOTCH IN PLATE 2- 1 3/4" MAX. IF BORED HOLE EXCEED 1 3/4" IN 2x4 TOP PLATE OR 2 3/4" IN 2x6 TOP PLATE STRAP E/S OF T EM #3 BELOW PLATEW/It 3- SIMPSON CS16x14" LONG NEW FOUNDATION METAL STRAP, TYPICAL @ < EACH PLATECUT W 16d's @ EACH SIDE!(6) 4- PIPE WHERE OCCURS 5- TOP PLATES/SILL PLATES 6- ANCHOR BOLTS PER PLANS #4 REBAR, 24" L @ 24" O.C. MAX. TIED AND EMBEDDEDMIN. 7- LOCATE ANCHOR BOLT 5" 6" INTO EXISTING MIN. 9" MAX. AWAY FROM FOOTING NOTCH OR END OF PLATE SLAB PER PLAN TE: -IF NOTCH OR HOLE EXCEEDS 50% OF TOP PLATE WIDTH, USE SIMPSON ST6224, STAGGERED @ E/S OF PLATES. -USE SIMPSON NS AS NEEDED EXIST'G FOUNDATION CLEAN AND ROUGHEN EXIST'G CON. SURFACE BEFORE PLACING NEW CONCRETE DRILL 3/4" 0 X 8 @45- HOLE AND SET # 4 @ 24" O.C. PER PLAN PIPING THRU PLATE FRAMING 6 DOWEL CONNECTION 2 N.T.S. N.T.S. 3-16D 2X TRIM (2-2X TRI OUCH AT OPE N SILL WIDER 4-16D _11EAD TRIMMER STUDS TO SUPPORT HEADER CRIPPL STUDS NAI LS FOR MER MMER ING THAN NAI LS FOR ER 'DRY WALL I STUD @ 16" O.C. TREATED WOOD OR OF TURAL RESISTANCE TO DECAY kTE WITH 7/32" D. X 3-1/2" SHOT IS @ 32" O.C. WITH 14" GAGE ZHERS & FIRST 2 PINS PLACED 0 0" FROM PLATE ENDS NCRETE SLAB PER PLAN (E)STUCCO WALL FRAMING 7 NON -BEARING INT. WALL TYP. N.T.S. N.T.S. N. CRICKET MIN. SLOPE 1/4" PER FT.---, 3 A35 @ I LR-30 TYP. (E.) 2" X 4" DBIL TOP EXISTING WALL---c--- PLATES VALLEY DETAIL N.T.S. Fticv REVISION: DATE: A 5123/05 DRAFTING SERVICE 13075 MAGNOLIA ST. GARDEN GROVE, CA 92844 TEL: (714) 925-3145 FAX: (714) 637-4188 SANAN SANTUCCI ROOM ADDITION 2210 S. GLENARBOR ST. SATA ANA) CA 92704 ALL DIMENSION, DESIGNS, SPECIFICATIONS REPRESENTED HEREIN ARE THE ORIGINAL AND UNPUBLISHED PROPERTY OF DRAGON CONSTRUCTION INC. AND SHALL NOT BE REPRODUCED, DISCLOSED OR USED BY OTHERS WITHOUT PRIOR WRITTEN CONSENT OF DRAGON CONSTRUCTION INC. VIEWING THESE CONDITIONS CONSTITUTES ACCEPTANCE OF THESE CONDITIONS. ALL RIGHTS RESERVED, DRAWN BY: Tony Vo DATE: 05-16-05 CHECK BY: DATE: FILE NAME: SHEET TITLE: Elevation Plan Details SHEET NO.: 3 OF 5 SHEETS J'A-3 Mr-W Ar)r)ITlr)KI FYICTIN(: r"1WPI IIMr, ROOF & FRAMING PLAN. Roof Covering #15 lbs. of felt over 1/2 OSB plywood Nailing schedule 6". 611. 1011 Panel span rating: 24 Finishing by 25 years comp. shingles (to ELK-AR5414) to match the existing roof covering: class "A" fire rate. ICBO: 3522 All lumber are Douglas Fir -Larch. #2 unless note All nailing are 8d, 16d common nails Galvanized sheet metal (25 gauge min.) roof valley flashing is required. Flat roof area has 1 /4" slope for drainage w/ felt hot mopped between or build up system Build up system: 2 layers #15 base sheet w/ cold apply & finished w/90 lbs. cap sheet Roof finishing matches existing style and color 4� 3/8" Plywood w/8d nails a@ 4" @ edges & 12" in the field 5/8" 0 A.B. @ 32" O.C. * New Living Space =1712 s. f. Ventilation require: 5.7 s.f. @ 1/300 * Ventilation provide: 4 - 24" dormer vents = 6.28 s"f" NOTE: INSTALL THE SKYLIGHT * FOLLOW THE MANUFACTURE'S INSTRUCTION FOR INSTALLING THE SKYLIGHT * CONFIRM LOCATION INSIDE AND OUTSIDE. * LUMBER (TO MATCH EXISTING RAFTER AND JOISTS. USUALLY: 2" X 4% 2" X 6", 2" X W OR 2" X 10") * LUMBER: CHANCES ARE YOU WILL BE CUTTING THROUGH RAFTERS AND CEILING JOISTS AND WILL NEED HEADER SUPPORT BATTEN MOUNTING BRACKET TIGHT JOINT BETWEEN HEAD FLASHING — ATTACH TO ROOF DECK FINISH GROOVE AND WITH SCREWS FURNISHED FINISH MATERIAL A WITH SKYLIGHT STEP FLASHING STANDARD FIXED SKYLIGHT STEP FLASH NG SILL FLASHING (E.) ROOF I I NEW HEADER TO BE I MATCH WITH EXISTING I ( ROOF RAFTER ' TIGHT JOINT BETWEEN r FINISH GROOVE AND I I ( DRYWALL FINISH MATERIAL DRYWALL 1Tlillll��` �h{IITIIIIIj �11 � •- •N A -A NEW HEADER TO : DRYWALLCEILING MATCH WITH EXISTING SKYLIGHT INSTALLATION. 1 DETAIL NEW HEADER TO BE MATCH WITH EXISTING CEILING JOIST I 1 (E.) R.R. { NEW HEADER TO BE 1 MATCH WITH EXISTING ROOF RAFTER 1 I (E.) C.J. I 7/8" EXTERIOR CEMENT PLASTER OVER METAL LATH OVER BUILDING PAP'" 1X8 BACKING BOAF 26 GA. GALV. METAL'Z' B) FLASHING. PAINT TO MATCH WA 26 GA. GALV. METAL RO TO WALL FLASHII PLYWOOD ROOF SHEATHINI RAFTERS W/ (2)16d TOE -NAILS TO LEDGE 3/8" X 5 LAG BOLTS @ 16 C APPROVED SIMPS( STRONG -TIE HANGS 2 X 6 LEDGEI NOTE: TYPICAL RADIANT BARRIER FOR T-24 ALL NEW ROOF AREAS 12 3 I,--� " 1/2" OSB PLWD ROOF SHEATH'G MIN. CLASS "A" C2 X FASCIA BN � �5-16 D EA. E VENTILATION. HOLES \ � L A35 @ 16'" O.C. EN. EACH TYP: H1 @ EACH 2" X 4" DBL TOP PLATES ROOF RAFTER (TYP.) R-13 TYP. STUCCO TYP: ----2" X 4" STUDS @ 16", O.C. FLASHING AT WALL 5 EAVE DETAIL N.T.S. N.T.S. NOTE: TYPICAL RADIANT BARRIER FOR T-24 NEW ROOF AREA R-13 2X4 STUD @16" O.C. CJ @1 V O.C. SIMPSON MSTA 24 @ 48" O.C. W/ SIMPSON NAILS . i i = w .. , TOE NAILS 2" X 8" RIDGE BOARD 2" X 6" METAL HANGER W/ JOIST HANGER NAILS STING WALL 2 X ROOF RAFTER R-30 @ 16" Q.C. INSULATION ADDITION ATTACH TO GARAGE RIDGE DETAIL. 2 N.T.S. N.T.S. NEW ROOF SHEATHING /NEW ROOF SHEATHING BN 1/2" OSB PLWD ROOF 2 X FASCIA SHEATH'G MIN. CLASS "B" B.N. CONT. 2 x 6 LEDGER W/ 16d @ V RAFTERS W/ 16" O.C. TO (2)16d TOE -NAILS BLOCKING BELOW 2-16d TO EACH TO LEDGER ROOF RAFTER A RAFTERS W/ (2)16d NEW ROOF SHEATHING TOE -NAILS TO LEDGER CONT. 2 x 6 — LEDGER W/ 16d @ 16" O.C. TO BLOCKING BELOW SOLID 2x BLOCKING L SOLID 2x BLOCKING EXISTING ROOF FRAMING (GARAGE RAFTER) CALIFORNIA DETAIL • "K 6"111111000MWA r AKE DETAIL il RAFTERS W/ (2)16d TOE -NAILS TO LEDGER CONT. 2 x 6 LEDGER W/ 16d Cc 16" O.C. TO BLOCKING BELO\ 2-16d TO EACH ROOF RAFTER —2" X 4" DBL TOP PLATES —R-13 TYP. -2" X 4" STUDS @ 16" O.G. KII=1A1 Rtltli= QWPATl INrZ WA CALIFORNIA FRMG. DETAIL M El REVISION: DATE: A 5/23/05 DRAFTING SERVICE 13075 MAGNOLIA ST. GARDEN GROVE, CA 92844 TEL: (714) 925-3145 FAX: (714) 637-4188 SANAN SANTU CC I ROOM ADDITION 2210 S. GLENARBOR ST. SATA ANA $ CA 92704 ALL DIMENSION, DESIGNS, SPECIFICATIONS REPRESENTED HEREIN ARE THE ORIGINAL AND UNPUBLISHED PROPERTY OF DRAGON CONSTRUCTION INC. AND SHALL NOT BE REPRODUCED, DISCLOSED OR USED BY OTHERS WITHOUT PRIOR WRITTEN CONSENT OF DRAGON CONSTRUCTION INC. VIEWING THESE CONDITIONS CONSTITUTES ACCEPTANCE OF THESE CONDITIONS. ALL RIGHTS RESERVED. DRAWN BY: Tony Vo DATE: 05-16-05 CHECK BY: DATE: FILE NAME: SHEET TITLE: Roof & Framing p Details SHEET NO.: 4 OF 5 SHEETS A�4 ;,,Cu misel Ly i m " ail 7 As� ; STRUCTURAL NOTES & SPECIFICATIONS General ������'�"«����� 1. The general contractor shall verify all dimensions and conditions mtsite. Any discrepancy found shall be reported to the Architect or Engineer. 2. All work shall conform to the minimum standards of the 2001 edition of the Uniform Building Code. 3. Structural changes made shall bemubmitti edbotho�nQinoerforvovi�wmndopprnv� 4. PorUonnofcnnotnuuUoonot covered byo�u�urm|design uhmUbeconstructed per peraon'232Gofthe U.B.C.. 5. The general contractor shall be responsible for adequacy and safety erections bracing, shoring and temporary supports. Foundation ���%�� v� x K���~���`'��� ^� `�^== ���n� 1. Design of foundation is based onclay, sandy clay, silty clay and calyey silt with allowable bearing value of1O0Opmfper table 1B-1,4nfU.B.C' ' 2. Contractor shall verify type of soil on site. He shall inform the Engineer if soil on site is inferior than the assumed soil type, 3. Soils With an expansion index greater than 20 shall not be used as fill supporting foundation of structure. 4. Fills and back fills shall becompacted hnBO96ofmaximum density. 5. The contractor shall be responsible for all shoring and bracing necessary to support cut and/or fill banks during excavation, and forming and placement ofconcrete G. Concrete slab shall be 4" thick with 6" x 6" - #10 / #10 welded wire mesh over 1 " sand over 6 mil vioquemnover 1"sand, 7. All hold down anchors and post bases shall be tied into place prior to foundation inspection. Lumber r 1. All wood bearing on concrete or masonry shall be pressure treated Douglas Fir or Redwood. 2. Structural members shall not be cut nor notched without the approval of the Engineer. 3. Metal anchors, fasteners, and connectors shall be Simpson Strong -Tie connectors. Substitutions must baapproved bythe Engineer. 4. All structural lumber shall beDouglas Fir -Larch with 1SY6maximum moisture content. - 5. Unless otherwise noted, use the following lumber grades: . 2x4studs Construction ofStud Grade - 2uGstuds No.2 2x studs No.2 4n1Obeams and smaller Nn.2 4x13beams and larger No.1 Gx studs Nu1 Posts and columns No.1 6, All nailing shall beper table |-QofU.B.C.unless otherwise noted. 7. Plywood floor and roof sheathing shall be laid continuous over two or more spans withface grain perpendicular to support. Stagger all plywood panels a minimum of 4 ft.. Nailing shall be inspected before covering. 8. Plywood sheathing exposed on the underside shall be bonded with exterior glue. 9. Roof sheathing shall be1/2^COXplywood (P.|.24/0)nailed with 8d@G"atboundaries and edges; 8d @ 1[Y'field nailing. 10. Floor sheathing shall be5/Q"(nininmn)T&<3(P.|.32/ 6)nsUedvvbh1Od@6"athuundoheoond edges; 1Od@1O"field nailing. 11. Wall studs shall be continuous between points of lateral support (balloon farmed) and not interrupted by horizontal plates. Such conditions are normally found on the walls found on the walls at gable end of vaulted ceiling and walls around stairs. 12. All bearing walls on a wood floor shall be supported with double joists or solid blocking unless noted ' otherwise. 13. Apply shear wall plywood prior hoall box-oudm.fupouto. soffits orany other framing that may interrupt continuity ofthe plywood shear wall. - 14. Double top plate lap splice shall beminimum of48"and Urdeosnoted other wioe.mhm||bobai}edtoQethor with a minimum of (8) 16d common nails per splice. Top plate breaks shall occur over a stud or post. 15. All hold downs shall befastened boa4x4post minimum, unless noted otherwise. 16. All exterior walls and interior bearing walls shall besecured tofoundation with 5/8" ¢^x10"anchor bolts @ maximum spacing of48''O.C. with 3k1G"x2"x2"bearing plates. Refer toshear wall schedule for anchor bolt size and spacing etshear walls. Structural ^� ��' H «�f�` � ����vu v�n���K���^x������������ �*T���x 1. All structural and miscellaneous steel shall conform to ASTM A-36 and shall be fabricated and erected in accordance with the latest edition ofthe AlG.C. Specification for the Design, Fabrication and Erection of Structural steel for Building. 2. Pipe columns shall conform bnASTMA,S3.grade B. 3. Steel rubes shall conform hn/\STK8A-5OO.grade B. 4. Bolts shall conform toASTIVIAr3O7. 5. Provide 3inch minimum cover around all structural steel below grade. O. All welding shall comply with /\.N(S.SpmcifinmUoneand shall badone bycertified welders, 7. All welding shall bedone byelectric are process with E70XXelectrodes. 8. All Welding shall bodone inthe shop ofolicensed fabricator. 9. Provide special inspection for all field welding. Manufactured Wood Products 1. All glued Laminated members shall be made of 1 - 1/2" Douglas Fir laminations, combination 24-F ^ per ARFwith the following allowable values: ^ ' Fb=3,4OU psi Fv=165 psi E=1.BUU.UOO psi ' 2. Glued laminated members shall beaccompanied byacertified ofinspection 3. All g|u(mmyshall have astandard camber unless noted otherwise. 4. Parallams shall be Parallam PSL 2.0 E by Truss joist Macmillan with the following allowable values: Fb=D.9OOpsi Fv=2HDpsi E=2.O0O.O8Opsi 5. Joists shall be TJI joists by Truss joists Macmillan and shall conform to NER 200. 6. Refer to Truss Joists Macmillan Specification for location and size of holes that maybe drilled through the web of TJI joists. Concrete Mason 1. Concrete block units shall be grade N-1, light weight, conforming to ASTM C-90. Minimum compressive strength, fn=1,5OOpsi. 2. Mortar shall betype k4 conforming to ASTM c-476.Minbmum compressive strength, Yo=2.00Opsi. 3. Grout shall conform toASTM o-476. Minimum compressive strength, fo=2.00Upsi. 4. All walls below grade shall bewaterproofed and positively drained. 5. Unless noted otherwise onthe plans, special inspection io notrequired for masonry construction. 1. Unless otherwise noted on the plans, concrete shall have nminimum compressive strength of 2.500 psi in 28 days. 2. Use type _CeWhmnt. 3. Aggregate shall conform to ASTM C-33. 1. Reinforcing steel shall be deformed steel conforming to the requirements of ASTM A-615grade 40, 2. Minimum cover for cast inplace concrete shall beaefollows: a)Poured against earth 3inches b) Walls exposed toweather: #5and smaller 2inohne #Gand larger 1.5incheu 3. Bars shall beclean orrust, grease orother material likely toimpair bond. 4. Minimum lap of reinforcement shall be 40 bar diameters. Lap horizontal bars at corners and intersections. CERTIFICATE ��� F COMPLIANCE ��K�������_U��U � «.�����. U UK-U»_��~�U �� RESIDENTIAL K���� Sainan Santucci ' 'May 16,28D5 Project Tile Date Project Address TonvVz [71 925-3 Documentation Author Telephone Package Compliance Method (Package orComputer) Climate Zone Enforcement Use Only Total Conditional Floor Area 490 ft.' Average Ceiling Height 8 ft.* Conditional Slab Floor Area 480 fLo Building Type: X Single Family )< Addition one ormore) Front Orientation: ��k�n� North /South / East West / All Orientations Number ofStories: 2 er of elling Units Floor Construction Type: Raised Floor (Circle one orboth) RADIANT BARRIER (required inclimate zones 2,4LR45) Required for this submittal X yes -no BUILDING ON Component Type Frame Type wd = wood Cavity Insulation Sheathing Insulation Total R-Value Assembly U-Factor Location/Comments (aftic, garage, typical, Wall Wood R-1 3 R-1 3 EXTERIOR WALLS Wall Roof Wood R-30 R-30 CEILING Roof Floor Concrete Floor Slab Edge For Drescriotive comoliance. Total R-Value and Assemblv LI-Factor are not reouired for a wood -Framed wall that meets cavil R-Valueinsulation requirements for the Prescriptive Package. Fenestration Shading Devices Fenestration # / Type Orientation Area (ft. 2) Fenestration U-Factor Fenestration SHGC Exterior Shading Aft. 0verhangs Fin Front Front Left NORTH 20 0.75 0.4 SHADED Yes Left Rear WEST 40.8 075 0.4 SHADED Yes Rear Right Right Skylight / � (Page 1of 2) MF-IR Note:Low rise residential buildings subject mthe Standards must contain these measures regardless mthe compliance approach used. Items marked with mmasterisk Omay umsuperseded by more stringent compliance requirements listed onthe Certificate ofCompliance. When this checklist m incorporated into the permit documents, the features noted shall be considered by all parties as minimums component performance specificationfor the mandatory measures whether they are shown elsewhere mthe documents or onthis checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures: § 150 (a): Minimum R-1 9 ceiling insulation. X § 150 (b): Loose fill insulation manufacturer's labeled R-Value. § 150 (a): Minimum R-13 wall insulation In wood framed walls or equivalent U-Factor in metal X frame walls (does Not apply to exterior mass wells) 150 (d): Minimum R-13 raised floor insulation in framed floors. 150 (1): Slab edge insulation -water absorption rate no greater than 0,3% water vapor transmission rate no greater than 2,0 perm / inch. § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form, X § 116-17: Fenestration Products, Extenior Doors, and Infiltration / Enfiltration Controls. X 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field-fabracated) have label with certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherwripped; all joints and penetrations caulked and sealed. § 150 (g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150 (0: Special Infiltration installed to comply with § 161 meets Commission quality standards. 150 (e): Installation of Fireplace, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closable metal or glass door. b. Outside air Intake with damper and control. C. Flue damper and control. 2. No continuous burning gas pilot lights allowed. Space Condition, Water Heafing and Plumbing System Measures: § 110-113: HVAC equipment, water heaters, shower heads, & faucets certified by the commission, § 150 (h): Heating and/or cooling loads calculated in accordance with ASRAE� SMACNA or ACCA. § 150 (1): Setback thermostat on all applicable heating and/or cooling system. X 1 . Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 ft. of pipes closest to water heater tank,non-recirculafing systems, insulated (R-4 or greater). 3. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirulating sections of hot water systems. 5. Cooling system piping below 55* F insulated. 6. Piping insulated between heating source and indirect hot water tank. x����K����U��8 ��. � COMPLIANCE �A�-U��8 CERTIFICATE U U K»~��~� U �_ ^��U� RESIDENTIAL U����Project Tile Date HVAC SYSTEMS Note: Input hydnoniccvcombined hydnmicdata under Water Heating Systems, except Design Heating Load. Heating Equipment ��hnum Distribution ' or Heat Pump ` ~~~ Thermostat ~~ Type Vumwm,heat, Efficiency and Location Piping Type Configuration oumnel:0 (AFasm*SPp) (dvcts.attic, etc.) R-Value (split or package) Existing FAU Cooling Equipment Minimum Duct Heat Type �*�n«m«n»� Efficiency Location DuctThermostat^~~ un�nn ~~'''� heat, vvm���m�/n� (SEER)���e�) R-Value Type (split orpackage) Existing FAU STD DUCT 4.2 SETBACK SPLIT SEALED DUCTS � � &m �� Measures) `w�����n� n���.�o �� ��� U������� x����u�00���� "�x��������^ OO Sealed Ducts (all climate zones) (installer testing and certification and HERS Rafter or field verification required) [] T%V'sCommission approved equivalent, readily accessible (climate zones 2and | 15nnly) (installer testing and certification and HERS Ratter or field verification required) OR [] Alternative hnSealed Ducts and TXVn (see Package CcvDAlternative Package Features for Project Climate Zone) Climate Zone Window SHGC Window U-Factor SEER Heating 8 0.35 0.4 (require vinyl frame doors & window) Water Heating Systems Water Distribution Number � inTank Energy Factor Standby External Heater Type Type System (kW or Btu/Hr) ---d�or- -----'-put ' Capacity or Recovery Loss Insulation (gallons) Efficiency R-Value GAS WATER HEATER GAS ONE 75 50 STD STD R-12 BLANKET For small gas storage water heaters (rated inputs of less, than mequal to 75,000 Btu/Hr), electric resistance, and heat pump water heaters, list Energy Factor. For Large Gas storage water heaters (rated input greater than 75,000 Btu/Hr), list rated input, Recovery Efficiency and Standby instantaneous gas water heaters, list rated input And recovery efficiency. SPECIAL FEATURES (Add extra sheets if necessary). Package Cand o:TXvxo,Commission approved equivalent, Sealed Ducts, Radiant oonmm(see Installation requirements for radiant barriers in Section 8.13 of the 1999 Residential Manual). Package C: thermal mass (thermal mass type, covering, thickness, and description). MANDATORY MEASURES CHECKLIST:_VES1DEWTt*;:-- (Page1 of2)MPAR Note:Lowmse residential buildings subject mthe Standards must contain these measures regardless ofthe compliance approach used. Items marked With an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimums component performance specificalion for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (Continued) All ducts and plenums Installed, sealed and insulated to meet the requirement of the 1998 CMC Sections 601, 603, 604, and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct system that meets the applicable requirement of LIL 181, UL 181A, or UL 181B. If mastic or tape is used to scale openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints mastic or tape is used to scale openings greater than 1/4 inch, the combination of mastic and either and scams of duct systems and their components shall be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan system have back draft or automatic dampers. 3. Gravity ventilation systems serving conditioned space have either automatic or readily accessible manually operated, dampers. 114: Pool and Spa Heating Systems and Equipment. 1. Systems is certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar healing. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional Inlets and a circulation pump time switch. § 115: Gas fired central fumac as, pool heaters, spa heaters or household cooking appliances have no, X continuously burning pilot, (Exception: Non -electrical cooking appliances with pilot < 150 Btu/Hr). Lighting Measures: §150 (k) 1: Luminaries for general lighting in kitchen shall have lamps with an efficacy of 40 lumenstwatt or greater for general fighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the $(lichen. §150 (k) 2: Rooms with a shower or bathtub must have either at least one huminaire with lamps with an efficacy of 40 lumens/waft or greater switched at the entrance to the room or one of the alternative to this X requirement allowed in § 150 (k) 2; and recessed ceiling fixture are IC (insulation cover) approved. (Page 3of 3) CF-1R COMPLIANCE STATEMENT This certificate nfcompliance lists the building features and performance specifications needed to comply with Title 24,Parts 1and Vofthe California Code of Regulations, and the administrative regulations to Implement them. This certificate has been signed hythe Individual with overall design responsiblility. The undersigned recognize that compliance using duct sealing and TXVs (or Commission approved equivalent) requires Installer testing and certification and field verification by an approved HERS rafter. Designer or Owner (per Business and Professions Code) Name: Sonen8antucci Title/Firm: OWNER Address: Glenabor St. Santa Ana, CA 92704 Telephone: (Signature) (Date) Enforcement Name: Title/Firm: Drating Service SanteAnaC/\927D4 Telephone: 714-892-7475 TmnyVo 5-23-05 (Signature) (Date) Documentation Author Name Title/Firm: Address: Telephone: (Signature) (Date) REVISION: DATE: DRAFTING SERVICE GARDEN GROVE, CA 92844 ROOM ADDITION ALL DIMENSION, DESIGNS, SPECIFICATIONS REPRESENTED HEREIN ARE THE ORIGINAL AND UNPUBLISHED PROPERTY OF DRAGON CONSTRUCTION INC. AND SHALL NOT BE REPRODUCED, DISCLOSED OR USED BY OTHERS WITHOUT PRIOR WRITTEN CONSENT OF DRAGON CONSTRUCTION INC. VIEWING THESE CONDITIONS CONSTITUTES ACCEPTANCE OF THESE CONDITIONS. ALL RIGHTS RESERVED. DRAWN BY: Tony Vo DATE: 05-16-05 CHECK BY: FILE NAME: SHEET TITLE: Title 24 A�5