HomeMy WebLinkAbout10148936.pdfSHEET INDEX A-1 PLOT PLAN A-2 FLOOR PLAN & 2ND FLOOR PLAN A-3 ELEVATIONS S-1 FOUNDATION PLAN S-2 FLOOR FRAM'G PLAN & ROOF FRAM' G PLAN SD-1 ESTRUCTURAL DETAILS 1 SD-2 STRUCTURAL DETAILS 2 D-1 GENERAL NOTES & DETAILS AD-1 ARCHITECTURAL DETAILS 11 GENERAL NOTES 1, ALL WORK SHALL BE DONE IN ACCORDANCE W/ THE 2001 CBC, PLUMBING, ELECTRICAL AND MECHANICAL CODES, 2_ VERIFY ALL DIMENSIONS, DO NOT SCALE DRAWINGS. 3. IT SHALL BE THE RESPON5ABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON THE SITE PRIOR TO COMMENCING WORK AND IS TO NOTIFY THE {OWNER AT ONCE UPON DISCOVERY OF ANY OMISSIONS OR CONFLICTS IN THE DRAWINGS. 4 PREPARATION OF BUILDING SITE SHALL BE PER SECTION 3302 CBCAALL STUMPS AND ROOTS SHALL BE REMOVED FROM THE SOIL TO A DEPTH OF AT LEAST 12 INCHES BELOW THE SURFACE OF THE GROUND TO BE OCCUPIED BY THE BUILDING) 5. ALL NAILING TO COMPLY W/ TABLE 23-11-8-i, CBC TYPE OF CONSTRUCTION VN OCCUPANCY GROUP R-3 / U-1 DEFFERED ITEMS TRUSSES I - TRUSSES PLANS AND CALCULATIONS WILL BE SUBMTTED AS A DEFERRED ITEM AND MUST BE SUBMITTED AND AC:EPTED BY THE BUILDING SAFETY DIVISION PRIOR TO FABRICATION TRUSSES AT SHEAR WALLS SHALL BE DESIGN AS 'DRA,; TRUSSES' AS INDICATED ON THE FRAMING PLANS IN ADDITION, THE TRUSSES SHALL COMPLY WITH THE FOLLOWING- EACH TRUSS SHALL OR WISE HAV PERMANENTLY AFFIXED ETHEREBTO LY H EANDEDFOLLOWINGEIN 4MA-IONRLOCATED E WITHIN 2 FEET OF THE CENTER OF THE SPAN ON THE F ACE OF THE BOTTOM CHORD, o> IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS. b) THE DESIGN LOAD c) THE SPACING OF THE TRUSSES TRUSS SUPPLIER SHALL SUBMIT CALCULATIONS AND SHCP DRAWINGS SIGNED BY A REGISTERED CIVIL ENGINEER TO THE RESPONSIBLE PROJECT DESIGNER WHO AGREES TO REVIEW THE SHOP DRAWINGS FOR ACCEPTANCE PRIOR TO FABRICATION. SHOP DRAWINGS & CALCULATIONS SHALL BE SUBMITTED TO THE BUILDING SAFETY DIVISION FOR ACCEPTANCE AFTER THE RESPONSIBLE PROJECT DESIGNER HAS NOTED HIS/HER ACCEPTANCE AND PRIOR TO FABRICATION. TRUSS DRAWINGS MUST REFLEC' COMPLIANCE WITH CBC SECTIONS: o. 166.3.2 PLANS, STRUCTURAL, CALCULATIONS & SPECIFICATIONS MUST BE BE PREPARED BY A CALIFORNIA REGISTERED CIVIL ENGINEER. c, 1704 REGULATION OF PREFABRICATED CONSTRUCTION INCLUDING REQUIRED INSPECTIONS AND CERTIFICA"IONS d. 2304.4.2 CONNECTORS AND FASTENERS SHALL BE INSTALLED IN ACCORDANCE WITH CBC CHAPTER 23, DIVISION AI. e. 2304.4.4 O TAL -PLATE CHAPTER -CONNECTED X ICSHALL 23 DIVISION V.ROVIDEEVIDENCEOF REQUIRED FABRICATION, STORAGE, HANDLING & DELIVERY INSPECTIONS. TJI S��� TJI PLANS AND CALCULATIONS WILL BE SUBMITTED AS A DEFERRED ITEM AND MUST BE SUBMITTED AND ACCEPTED BY THE BUILDING SAFETY DIVISION PRIOR TO FABRICATION SEE TJINOTE ON SHEET S-2 GENEMIL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 C.B.C. PLUMBING AND MECHANICAL CODES, THE C.E.C. AND LOCAL ORDINANCES. 2. VERIFY ALL DIMENSIONS, DO NOT SCALE DRAWINGS. 3. IT SHALL BE THE RESPONSABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON THE SITE PRIOR TO COMMENCING WORK AND IS TO NOTIFY THE OWNER AT ONCE UPON DISCOVER OF ANY OMISSIONS OR CONFLICT IN THE DRAWINGS. 4. ALL NAILING TO COMPLY WITH TABLE 2341-B-1 C.S.C. 5. THE MANUFACTURED WINDOWS SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE NATIONAL FENESTRATION RATING COUNCIL (NFRC) AND SHOWING COMPLIANCE WITH THE ENERGY CALCULATIONS. 6. LIGHT AND VENTILATION PER C.B.C. SECTION 1202. MINIMUM OF 15 C.F.M. OF OUTSIDE AIR PER OCCUPANT IS REQUIRED FOR VENTILATION. PLUMBING NOTES 7. ALL PLUMBING WALLS TO BE 2" x 6" 8. DOUBLE WALLS USED AS PLUMBING WALLS ARE TO BE A MINIMUM OF 8" WIDE AND NO "FLAT" STUDS PERMITTED. STAGGERED STUDS ARE ACCEPTABLE. 9. SMOOTH, HARD, NON ABSORBENT SURFACE IS PROVIDED TO A HEIGHT OF 70" ABOVE THE DRAIN INLET OF THE SHOWER OR TUB/SHOWER COMBINATION, MATERIALS SHALL BE OF A TYPE NOT ADVERSELY AFFECTED BY MOISTURE. 10, GLASS ENCLOSURE DOORS AND PANELS MUST BE LABELED CATEGORY If. NET AREA OF SHOWER RECEPTOR SHALL BE NO LESS THAN 1024 SQ IN OF FLOOR AREA, AND ENCOMPASS 30"DIAMETER CIRCLE. 11. ALL WATER CLOSETSMARE LOCATED IN A CLEAR SPACE NOT LESS THAN 30" WIDTH AND HAVE 24" MIN. CLEARANCE IN FRONT OF THE STOOL. 12. FOR EXHAUST VENTILATION AIR, PROVIDE MECHANICAL FAN 5 AIR CHANGES PER HOUR. 13. WATER HEATER TO BE BRACED TO RESIST SEISMIC FORCES, PROVIDE TWO STRAPS (ONE STRAP AT TOP 113 OF THE TANK AND ONE STRAP AT BOTTOM 1/3 OF THE TANK). 14, ALL NEW WATER CLOSETS WISH USE NO MORE THAN 1.6 GALLONS PER FLUSH. ELECTRIC NOTES 16. RECEPTACLE OUTLETS LOCATIONS WILL COMPLY WITH NEC Art 210-52 (a) "20 AMP. CIRCUIT DEDICATED TO EACH BATHROOM„ 16. ALL BEDROOM CIRCUITS REQUIRE ARC -FAULT PROTECTION, 17. GROUND -FAULT CIRCUIT INTERRUPTER (CFI) PROTECTION COMPLIES WITH NEC Art. 210-8: "ALL 125 volt SINGLE PHASE, 15 AND 20 AMPERES RECEPTACLES INSTALLED IN BATHROOMS, GARAGES, BASEMENTS, OUTDOORS, KITCHEN COUNTERS AND AT -WET BAR SINKS. STRUCTURAL NOTES 18, THE CONTRACTOR SHALL PROVIDE ANY SHORING AND/OR BRACING TO THE EXISTING STRUCTURE WICH MAY BE REQUIRED DURING CONSTRUCTION, 19, PERMISSIBLE NOTCHING AND BORING OF JOISTS ARE TO BE SHOWN ON THE PLANS AND SHALL NOT EXCEED CBC SECTION 2320.8.3 ALLOWANCES. 20. NOTCHING OF EXTERIOR AND BEARINGINONBEARING WALLS SHALL NOT EXCEED 25°/a140% RESPECTIVELY. BORED HOLES 1N BEARING/NONBEARING WALLS SHALL NOT EXCEED 40%/60% RESPECTIVELY. IN NO CASE SHALL THE EDGE OF THE BORED HOLE NEARER THAN 618" TO THE EDGE OF THE STUD (2320.11.9 AND 2320.11.10) 21. HEADER AND TRIMMER DETAILS FOR DOORS AND WINDOWS ARE TO BE SHOWN WITH THE FULL LENGTH TRIMMERS, SPECIFYING THE SIZE OF THE HEADER AND TRIMMER (2320.11.6) 22. USE SIMPSON ST 6224 TO TIE4N TO EXISTING TOP PLATES. SPECIAL INSPECTION REQUIRED 1. EPDXY BOLTS 2.- THE STRUCTURAL ENGINEER OF RECORD SHALL PROVIDE INSPECTION FOR ALL STRUCTURAL ELEMENTS TO INSURE COMPLETED CONSTRUCTION. PRIOR TO THE BUILD'G SAFETY DIVISION'S FINAL INSPECTION, THE STRUCTURAL ENGINEER OF RECORD SHALL SUBMIT A LETTER TO THE BUILD' G OFICIAL CERTIFYING COMPLETED STRUCTURAL ELEMENTS. I 46.16' A 00 46.16' .h�.'90'e17 ll•j 1! 1 AREA ANALISY LOT AREA 5401 sq ft :XISTING SFR 1*410 sq ft EXISTING GARAGE 400 sq ft PROPOSED ADDITION (-%1ST FLR, * .44(2ND FLR) !M `.b,sq ft TOTAL LIVING AREA "2 ;e>> sq ft TOTAL CONSTRUCTION '22-3-1 sq ft LOT COVERAGE I oa PLU"T LAI, sc-1,8-1 w-o°° j I 1 � s KPlae[ Mt aie.L } � i 3 I I PH 714 / 835 1585 Fx 714 / 835 1428 2017 W. ALCO AVE. SANTA ANA CALIFORNIA 92703 AADRAFTINGOMSN. COM _ REVISIONS A A� ��OFESS10 7 CO Z c" N.G 25 m w cc 3131106 �k t civil. OF C(0) M. SITE: 0 1 101-112. (714) 557 8949 Joe DE5CRIPTION: . SQ FT ADDITION IST FLR: CLOSET EXPANSION & WATER HEATER RELOCATION 2ND FLR: (2 BEDROOMS I BATHROOM). PLOT P If If STAIRS )RS, FROM INDIVIDUAL DWELLING UNITS HAVING AN IT LOAD OF 10 OR LESS MAY BE PROVIDED W/ NIGHT EAD BOLT OR. SECURITY CHAIN, PROVIDED SUCH ARE OPENABLE FROM THE INSIDE WITHOUT THE KEY OR TOOL OR SPECIAL KNOWLEDGE OR EFFORT JNTED AT A HEIGHT NOT TO EXCEED 48 IN. ABOVE ;H FLOOR. .ESS OF THE OCCUPANT LOAD, THERE SHALL BE A Z LANDING ON EACH SIDE OF A DOOR. THE FLOOR OR I SHALL NOT BE MORE THAN ONE -INCH LOWER THAN :.�SHOLD OF THE DOORWAY. LANDINGS SHALL BE .CEPT FOR EXTERIOR LANDINGS, WHICH MAY HAVE ,qOT TO EXCEED 1/4UNIT' VERTICAL IN 12 UNITS TAL (2% SLOPE). qS: OR MAY AT A LANDING THAT IS NOT MORE THAN 71/2" ER THAN THE FLOOR LEVEL PROVIDED THE DOOR DOES SWING OVER THE LANDING. ;EN DOORS AND STORM DOORS MAY SWING OVER STAIRS S OR LANDINGS. R.S SERVING BUILING EQUIPMENT ROOMS WHICH ARE NORMALLY OCCUPIED, I N T-5" M TITLE 24 SUMMARY ENERGY (TITLE 24) REQUIREMENTS INSULATION EXT WALLS: R-13 SUBFLOOR: R-19 ATTIC: R-30 FENESTRATION FENESTRATION:' U-FACTOR=.75 max SHGC= .40 max A/C EFFICIENCY N/A RADIANT BARRIER EMISSIVITY LESS OR EQUAL TO 0.05 INSTALLED TO COVER ROOF RAFTERS AND GABLE ENDS WALLS AT ATTICS (D FLOOR PLAN NOTES 1. 2X6 PLUMBING WALL 2. N/A 3. SHELF AND POLE 4. REC'D MEDICINE CABINET 5. 40 K BTU MIN. NAT. GAS WALL HEATER PROVIDE FUEL GAS 6. HANDRAIL PER 7. CABINET PER OWNER 8, RELOCATED 50 GAL. WATER HEATER ON 18" PLYWOOD PLATFORM. PROVIDE FUEL GAS, NOWRIDGID CONNECTION AND SEIMIC STRAPS. DOOR TO BE 2068 SC W/ 12 SO.IN LOUVERED VENTS WITHIN THE TOP & BOT 12 INCHES OF THE DOOR. 9. PROVIDE %" TYPE 'X'DRYWALL AT WALLS AND CEILING UNDER STAIRS AS REQUIRED 10. TOILETA1.6 GAL PER FLUSH MAX) ii. F.G. TUB/ SHOWER. W/ GLASS ENCLOSURE DOORS & PANELS MUST BE LABELED CATEGORY 11 CLASSIFICATION PER CBC CHAPTER 24 AND UBC SiD. 24-2 NET AREA OF SHOWER SHALL BE NO LESS THAN 1024 SO. IN. OF FLOOR AREA, & ENCOMPASS 30" DIA, CIRCLE. FIBER GLASS SHOWER WALLS MIN. 70" ABOVE DRAIN. LEGEND llo� SMOKE VE DETEW/ BATCTTORERY BACK-UP BATTERY OPERATED SMOKE DETECTOR NOTE. 9V SMOKE DETECTOR PROVIDE SMOKE DETECTORS ACCESS BEDROOM @ RECESSED CEILING LIGHT AND CORRIDOR OR HALLWAY ACCESSING SUCH BEDROOMS PER SECTION 310.9.1.3 & 310.0.1.4 RECESSED ,,MINI LIGHT 2001 CBC. SEE NOTE "I" BELOW FOR S.0 IN EXISTING BEDROOMS WALL MOUNTED LIGHT CEILING L16HT 112 HOT 110V 0 -12" U.N.O. 110V OUTLET I_* FUEL GAS M& 220V OUTLET GFI GROUND FAULT INTERRUPTER 1$ SWITCH �$3 3-WAY SWITCH HOSE BIB HOSE SMS TO HAVE A NON-REMOVMLE BACK -FLOW PREVENTER OR WITH A LISTED AIR DIFFUSER GRILLE ATMOSPHERIC VACUUM BREAKER. FL FLUORESCENT AS REQUIRED MECHANICAL FAN. MI 5 'AIR CHANGES PER HR. FLUORESCENT LIGHT LOG LIGHTER PLUMB FOR ICE MAKER TELEPHONE JACK An RECEPTACLE OUTLETS SUPPLIED BY BRANCH CIRCUITS PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER SECOND FLOOR PLAN FIRST FLOOR PLAN WALL LEGEND 1111111111011111111 740 SQ FT NEW WALLS SQ FT EXISTING WALLS TO REMAIN 3 EXISTING -WALLS TO REMOVED #=Z# (LD ,P IEPA FED 8r: -7-1 t�4 0 T -4- M 0 ArPoe, D PC, z < PH 714 8 3 51 15 8 5 7: FX 714 / 835 1428 2017 W. ALCO AVE. SANTAANA CALIFORNIA 92703 Z AADRAFTINGOMSN.COM w REVISIONS w (I 0 A 0 I.- 0 D z 205 E s/3i/06 z pT CIVIL 0 OF CAOIF c: I-- co z SITE. cc w a. la ir 0 z 10 0 10 cc w z < z 3: 0 00 z w < z X 0 CL I.- < z 0 < LL 0 z Z z w 0 I- o<t 0 w w This Set OPl D LL) fts cc nta z w ton, 2 . to Pori D 0 04 0 Q JOSECER AN 557 Wd 3: (714 1%,Zzz t z Fr 0 w JOB DESCRIPTION: z SO T ADD C� 1 'ION IST F R: C SET EXPANSI & ATER co HEATER R ATION a 2ND FLR: {2 BEDROOMS 0 cc IBATHROOK z 0 to FLOOR PLAN 0, 0 a: Ir w z DRAWN: AL CHECKED: DATE: -04-04 JOB NO: 001-04 SHEET NUMBER: A-2 Dec w N N L - ..... ..... 11/14 qapa -Tr I H xf -v4p ATTIC VENTILATION - ATTIC AREA- 785 SQ FT ATTIC VENT REQ'D- 754 SO IN. 1154 SO IN. PROVIDED IN (8)12"SO LOUVERED, G.I. SCREENED ATTIC VENTS . m 7 0 A r of a e, L 'I, a � e L a c' to z < PH 714 835 1 1585 1 FX 714 t 835 1428 2017 W. ALCO AVE. SANTA ANA CALIFORNIA 92703 Z AADRAFTINGOMSN.COM w REVISIONS w o A (L A 0 '-- A Ir A (L (o OFESS/0 Lu m uwj 43205 w m < x 131106 m I co z 0 civi OF CALIF rr Z SITE: Cc 0 ss rJ iz 10 0 w z < O 0, 1z 0 w z w err < 0 w< z 0 < I- z < 0 z z z w F t < < w A /Ar w pi Erjd w c 4s Ana. z w t� ow por be 0 city 0, JOSE CERVANTES w C'TVOF .(714)557 89 t 0 to lu JOB DESCRIPTION. 0 0 z 0 EXTERIOR 0 ELEVATIONS i - ir 0 ir ir L11 z 77 DR DRAWN: AL CHECKED: DATE: JOB NO: 001-04 SHEET NUMBER: A-3 m' •- M ♦ ! 1R0 7 l rt fi r� .. .► . - -"' ill► � ��_,,.I� i 1► - � '�� 2. EXIS`,' CONCRETE SLAB /f.Atstfp 3. NEW CONC. FTN`6. (5" W X 18" D Wr 2-114 TOP 4 BOTTOM MIN.) 4. NEW 4"TI.1K CONC. SLAB Wt 6 XV'/ 10' 10* WEUF OVER 2" SAND OVER 6 MIL VAPOR BARRIER OVER COMPACTED EARTH. $. NEW INTERIOR CONCRETE FTNCs OVID X IS" D W/ 1-04 TOP t SOT, MIN,) 6. EXISTG 12"X 12" MIN, CONC, FTN'G (VERIFY) sWt- 1. 18" L. 04 REBAR DOWELL s 24" O.C. 6" INTO EXISTING FOOT IG W/ "EPDXY" 8. 24" L. 04 REBAR DOWELL TOP AND BOTTOM AT NEW TO EXISTING FTNC 6" INTO (E) FTN'Cs W/ "EPDXY" S. GONG. LANDING (3 'r2 " THK W/ 6"X6"- IgrX10' ULF.) 10. GONG PORCH SLAB (4'" THK W/ 6"X6"-10'X'10 WWF) 0/ 2" SAND OVER COMPACTER EARTH. FLOUR. NOTE: PIPES, DUCTS AND OTHER NONSTRUCTURAL CONSTRUCTION SHALL NOT INTERFERE WITH ACCESSIBILITY TO OR WITHIN UNDERFLOOR AREA. MINIMUM NOMINAL ANCHOR BOLT 01A. SHALL BE **a INCH SPACED PER SHEAR SCHEDULE OR * W-0" OC. MAX. EMBEDED INTO CONCRETE I" MIN, W/ MIN, DISTANCE FROM THE END OF SILL PLATES TO BE 4 tt12 " ( AND A MAXIMUM OF 12"). PLATE WASHERS (MIN. SIZE OF 2" X 2" X 3/16 ") SHALL BE USED ON EACH ANCHOR BOLT NOTES- r ,- LOCATION W1 FLR. PLAN -WOLDOWN ANCHORS+r IN PLACE PRIOR TO FOUNDATION INSPECTION. -SURFACE WATER WILL DRAIN AWAY FROM BUILEX6. d. WOLD-0OWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APP • s► ► r ,SHALL BE TIGHTENED JUST PRIOR Ti COVERING a, ALL INTERIOR NON -BEARING: WALLS WITH SHOT PINS. RANSET '334$. OR SQUIVALENT. AT 36" ac. UNLESS OTHERWISE NOTED. f. *s" DIA A. B. MAY BE REPLACED BY %" DIA THREADED RODS Wt 5-2i " EMBED. WITH CIA -GEL "IM0 EPDXY SYSTEM 1. C. B. O. ER. 4846. (OR EQUIVALENT), AT THE SAME SPACING. mam l rrI !f l r _ EXISTING FOOT -6 a NEW FOOT'Cs PPEPARED 8 kqj ([ 4 O T ArIl aI?Lt Mp�Gt eL `L�xciL z PH '714 % 835` 1585 x Fx 714 I 835 1428 2017 W. ALCO AVE, SANTA ANA 0 CALIFORNIA 92703 Z AADRAFTINGOMSN. COM w REVISIONS 0 0 ir 0. O F £r 0 cc za wssiQ �" F Off' m 43205 rn 3/31106 0 OF cp01�0� O F Z SITE: cc w a 0 ir O F a CC r z 0 0 z O vj< I= a U- O (ozz w w 0� r r w O �) 0 with r z OWNS C sT01 w JOSE CERVANTES SANTA z r Z (714) 557 8949 t 0 Z m ta_ C} O 0 w JOB DESCRIPTION: z rT ADDITION a. IST FLR: CLOSET EXPANSION & WATER co HEATER RELOCATION 0 2ND FLR: (2 BEDROOMS Q I BATHROOM). z 0 FOUNDATION 0 PLAN C a a w z a ■r��r.rrwe. DRAWN: AL CHECKED DATE: DEC-04-04 JOB NO: 001-04 SHEET NUMBER- 9 P?REPA ED Br. oil ROOF FRAMING PLAN ROOF SHEATHING: 4 i i 4X& NDR A� 4 ST. CIO AL NEW I ROOF 12� 9=TQ :T m --T EXISTING _73�12 ROOF ITCH j -CH+ 7-1 z I to FLOOR SHEATHING. It D1j Sol NIaft,, & 31/2" X 16" PSL FLUSH SIMP ST6224 R.4979 0 NEW TO EXIST G TOP PLT. N� x 0 V HF i X32 OX24 jPff C 9,34 PF95,342 16" TJI PFW-21,0�`; q - I t6236 4. D8L fi Sty1 ]1 ciif, x v-6- HANDRAIL. 8 FT CL'G' II ID N Alin X i> PST. PF-4� T W/ SIMP Ecc asirp X 51-�711 a Fv CL-C, Z' 20 naill Sol -j 31/ PSL FLUt, w 4X4 PST. Wt SIMP SA- uj @2 0 es 4X4 PST. ASOVE PPL- 7F -S SIMP MIT'M 4X8 PST. AT ECH JOT MI/ VMP EGG Spt 4 1-151-18 T".v ER 49 IS w O� 2 312 k go 6 Sol POST W/ EPC oF-I rarrIftle T. C014mig -.-01 4X& (E) 4X4 PST. WDR II HOi W/ SIMP L - 4X4 PST. W/wo--v uil $IMP I -Ric SIMP 5T6224 F,p,&"tqq 0 NEW TO EXIST'G TOP PLT. 3 FLOO1 FRAMING PLA jj00F'G MATERIAL ASPHALT SHINGLE CLASS "C" OR BETTER 0/ # 15 FELT UNDERLAYMENT, OWENS CORNING BRAND ICBO # ER-5443. SEE SHEET D1 FOR SHEAR WALL SCHEDULE FRAMING NOTES t ROOF SHEATHING: (SEE PLAN) (USE1X6 SOLID SHEATING OR A-C GRADE PLYWOOD AT EAVES & OVERHANG) FACE GRAIN PERP. TO SUPPORTS 2. PROVIDE FULL LENGHT TRIMMERS AS FOLLOWS' 4X POST AT EACH END OF 4XI0 OR LARGER MEMBERS, DOUBLE STUDS FOR 4X8 SINGLE STUD FOR 4X6 OR SMALLER MEMBERS 10 3. FOR TYP. STUD WALL FRAMING SEE 4. B.N. ALONG STUDS 5. FLOOR SHEATHING: (SEE PLAN)' FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. 6. PROVIDE MULTIPLE STUDS UNDER MULTIPLE JOISTS 7. PROVIDE FULL BEARING W/SOLID BLOCKING OR SHIMMING BELOW ALL POSTS AT FLOOR. Qt 8. SEE DEPS FOR ALLOWED BORING AND NOTCHING OF JOISTS & STUDS 9. 2 LAYERS OF 15- FELT SHALL BE USED AT ALL STUCCO AlfFLIED OVER PLYWOOD. 10. MIN. 2X6 STUDS @ 16" O.C. AT PLUMBING WALLS. 11. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS 12. DOUBLE JOIST ARE REQUIRED UNDER PARALLEL BEARING PARTITIONS NOTE* TJI TRUSS JOIST TO BE EQUAL TO "TRUS JOIST" A WEYERHAEUSER BUSINESS. DESIGNED PER L/480 LOAD DEFLECTION MANUFACTURER RESPONSABLE FOR VERIFYNG ALL CONDITIONS W/ FRAMING CONTRACTOR FOR "STEP DOWNS", TAPERS". "CANTILEVERS" & ASSOCIATED CONNECTIONS . TJI FRAMING PLAN LAYOUT SHALL BE PREPARED BY MANUFACTURER AND PROVIDED TO CONTRACTOR. ANY NOTCHING, DRILLING OR CUTTING SHALL BE PER MANUFACTURER'S INSTRUCTIONS AND APPROVED BY THE PROJECT ENGINEER, CONSTRUCTION NOTE: REMOVE ALL EXISTING ROOF FRAMING AT NEW 2- STORY ADDITION AND AT FRONT ROOF LEGEND CALIFORNIA FRAMIW, SOFFIT FRAMING SHELF 07-�2M INTERIOR BEARING WALL 48� HARDI FRAME PER PLAN 0 3� 1- T e, U W e L < PH 714 835 1585 1 FX 714 f 835 1428 2017 W.ALCO AVE- SANTA ANA CALIFORNIA 92703 Z AADRAFTINGOMSN.COM a w REVISIONS w 0 0 cc a- A 0 I- A cc 0- 0 OFE Sj, w CO to 0. 205 a: /31/06 z 0 OF c Z SITE: Ir w 0 cc (L 0 z 0 Q 0 ir w z < z 00 3: 0 Ar tu z uj rr < [w X < z OX z a IM < vj < 2 u. F-w 0 z (0Z z 0< r—vj w a 4�� w D w 3:, w JOSE CERVANT 0 w (714) 55-7 894I?i cc a: D 0 JOB DESCRIPTION: FT ADDITION 4ST FLR: CLOSET EXPANSION 8, WATER HEATER RELOCATION 2ND FLR: (Z BEDROOMS 0 Ir IBATHROOM). z 0 FRAMING 0 PLAN 0 cr z DRAWN: AL CHECKED: DATE: DEC-04-04 JOB NO: 001-04_ SHEET NUMBER: S 2 2x STUDS @ 16-0/c ;IMPSON CS 16 X 5'—S' SILL NAILING -ONG W/ 10d NAILS 0 B.N. FLOOR SHT'G. D3" O.C. STAGGERED E.N. _TJI FLOOR JOIST PER PLAN 2X STUDS 0 16* O.C. 16d 0 8"0/ \�—TJI BLOCKING —USE CONT. BOTH SIDE E.N. TIMBERSTRAND RIM JOIST W/ (STAGGERED) SIMP. A35 @ 16"O/C AS AN ALTERNATE 2-2x TOP PLATE 4!z_ 2x STUDS @ 16-0/c STRAP @ WALL TJI JOIST THIS SIDE WHERE 0( 17 TJI W/JOIST HGR. 2X BLK'G„ 2X LEDGER W/ PER MFR. W/1 f3d@8O.C. 2-16d @ EA. STUD TO LEDGER TYP. ROOF SHTG PER PLAN Cillocnki TC0 E.N. \-BEAM PER PLAN @48"O.C. E.N 2X RR 4 PER PLAN E.N. 2X BLK'G E.N. CONT. 2X BLK'G —TJI BLK'G. W/16d SHEARPANEL 048"O.C. 8 LK'G & W/ 0 8"O/C E.S. WEB E.N. @ PLYWD 2X STUDS 01 6"O.C. SHEARWALL WALL FINISH ON LY PER PLAN TJI EA. SIDE (SEE PLAN) BEAM PER PLAN nB @) SHEAR TRANSFER PAEPAf�ED BY: E.N. TO BLOCKING i OF STRAP) 4x BLOCKING CS STRAP F, ST2315 0 48" O.C. C83 IN IN LIEU OF 2X4 TIES 1 Od @ 3"07C 1 Od @ 6"SHEARWALL PER PLAN-1 O/C (SEE NOTE) DOTE. 2X R!r)GE BOARD ry _-N E.N. (TYP.) SECTION PLYWOOD SHALL BE 2X48 J OCTIES 0 SIMP' CS16 W/8d 0 3_16d TYP. ALL AROUND OPENING Z'> T­_A fF Ff N4 <_�j - - - - - - 4"0/'C (TYP. +T&B AT (ABOVE &,BELOW) PLYWD ROOF WINDOWS, TOP ONLY SHT G PER PLAN AT DOORS} SYM. 4x LOCKING FLOO JOIST RR PER PLAN PER LAN 0 T Arl?lc�eLb TI:E T-11 lilt III F-1 D AL f Ilk /-4x BLK'G. CJ/TIE PER PLAN z DBL. BLOCKING HEADER / 9,WINDOW (4) 16d 0 48 714 PER PLAN OP 'G. Typ. I I W) PH ) 835 1585 SILL f?_ @ 2'- 6" MIN. CONT. TO END OPWGS. O.C. MIN. TO R.R. 1 FX 714 / 835 1428 t 2017 W. ALco AVE. WINDO ORCO T. OF SHEARWALL SIMPSON CS16 x 10'-0" SANTA ANA OPN*(3v/ S. 0 CALIFORNIA 92703 Z AADRAFTINGOMSN.COM DBL STUD OR POST 2X6 TIES 0 48" O.C. REVISIONS PER PLAN W/ (4) 16d EA, END DBL PLATES AS OCCUR PER PLANS AT HIP ROOF A 0 TYP. STRAP @ S. W. OPN'G. RIDGE A 0 13 0 OFESsl _2X RAFTER 'CALIFORNIA" 43205 --POST PER PLANT 1 FRAMED PLYWD SHT'G --SIMPSON ST6236 W/ 12- 16d PER PLAN z clo.0 O� '0 a EA. END OR MST48 W/ q OF CA 17- 16d 0 EA. END cc SITE: 'N DOUBLE 2X EN BLOCKING iL 0 WC1 c: 2X CONT ir t. POST STRAP 1814 Fcz SCREW HARDY PANEL TO TOP. It W/1/4"O 3" HFS OR SIDS 2-2x TOP SCREWS SEE SCHEDULE FOR NO. REQ'D SCREW HARDY PANEL <, "19 TO KING STUD WHERE OCCURS W/4-1/4"o x 1 1/4" HFS OR SCIS I I I SCREWS .(TYP.) "HARDY PANEL" SEE PLAN FOR MODEL NO. FLU (z 0 9 C-A f4 I i T- — HEADER WHERE I7L�OCCURS IKING STUD rl; W'r, t 74 WHERE OCCURS HARDY PANEL D ETAl L 15 SEE SCHED. FOR LENGTH SCREW HARDY FRAME TO TOP PLYWOOD SHT'G. IE W/1/4"o x 3" HFS OR SDS 2x SOLID PER PLAN SCREWS - SEE - SCHEDULE FOR BLK'G. SIMP. A35F N 0. R EQD. 0 16..O/c 2-2x TOP SCREW KING STUD 7x 'Sly"7p, WHERE OCCURS TO s-N. I HARDY FRAME W/4-, ezi 1 #10 x 2 1/2" 1 SCREWS (TYP.) L- - - - _J "HARDY FRAME" SEE PLAN FOR MODEL NO. LHEADER WHERE OCCURS (2 L_,A A-1 KING STUD WHERE OCCURS 26 HARDY FRAME DETAIL 16 WALL FINISH PER PLAN SIMPSON TSE 48"O.C. 2X STUDS — @ 16"0. C. ROOF ME E.N. 16d @ 8"O/C— BOTH SIDES (STAGGERED) E.N. 2-2x TOP PLATE— 10. 2X BLKG W/ 16d08"O.C. TO LEDGER TYP. 2X LEDGER W/3-16d @EA E.N. STUD S A T U, — 00, 'G -ROOF SHT'G RR 16d @8"O.C. --CONT SHEAR PANEL W/ BLK'G AND E.N. 0 PLYWD A. SHEARWALL ONLY 2x STUDS @ 16"O/C -SILL NAILING FLOOR SHT'G. B.N. TJI FLOOR JOIST PER PLAN TJI BLOCKING BY MFR. 0 48"O/C (MAX.) CONT. TJI RIM JOIST — USE TIMBERSTRAND W/SIMP. A35 0 16"O/C AS AN ALTERNATE 2x STUDS @ 16-0/c "SHAPED llw/ 16d 06 moc 2X BLK'G z 0 RAFTERS w Z< NOTE: IN LIEU OF 2X BLOCKING, NAIL 2X z U2_ SHAPED W/ 2-1.6d EACH RAFTER 00 w CALIFORNIA FRAMED ROOF z < z 2 IL < -------- ------- z 0 U) <r PLYWD SHT'G —2X4 FLAT CONT. 0 RJ OR RR z SIMPSON ST6236 PER PLAN PER' PLAN 0 32'OC z z BN lu 0 F_ ir SIMPSON EPC 2-16d— 3: T—v) w 2-16d LET -IN 2X4 w EN EN 2X BARGE 2X BLK'G 04-8*OC w 74?1 J'PLA PLATE FIRST BAY ONLY 2-2X TOP .2X BLK'G W lo PLATE Udl 6d 0 .8"OC ALT: E SIMP. A35 ir Z PLAN 0 24"OC —WALL FINISH -PER PLAN z F, w OWNE V 0 trtsd Is's SHEAR TRANSFER. Z 1 (714) 557 8949 t 0 3 z it cc 0 0) CJ PER PLAN T JOB DESCRIPTION: W/3-16dO RR PER PLAN 0 -2 - -2-v 12ooF- AFlt_R END z < SQ FT 2-STORY I PLYWD SHT'G PER PLAN 14/ w ADDITION) (NEW BEDROOM 8t RELOCATE BATHROOM uk4vltr- AND EXPAND LIVING BN ALTERNATE LOC. DINING ROOM). 2X BLK'G TO MATCH 0 EXIST'G z 2X BLK'G W/16d0 EN EN 8*0.C. ALT. USE 2 STRUCTURAL SIMP. A35 '0 24"O.C. 0 11 DETAILS 2-2X TOP PLATEO 00 WALL FINISH PER PLAN cc w 2X STUDS 016" 'o >_ FACIA TO MATCH z O.C. UNO r7VlcZT'f_l OR < ol SEE ARCH DETAIL SHEAR TRANSFER i-T DRAWN: AL CHECKED: DATE: JOB NO: AuG-04-04 001-04 SHEET NUMBER: S D-1 -- - -- ------ F 4 0 4 1/2" HFS OR SDS SCREWS 1 PLYWOOD SUBFLOOR WALL PER PLAN STUD WALL MAY --\---\/\ PER SCHED. /-TJi SOLID BLK'G. 2 3/4" PLYWOOD TREADS & RISERS SH71 °G NOT OCCUR HERE 2X SILL KING STUD 3 DOUBLE JOIST OR HEADER SN "HARDY PANEL" MODEL NO. FOR I SCREW H 5 2X12 STRINGERS (MIN 3) PER PLAN (SEE PLAN) P I­YW ; I �. � I 2X BLKG @ D SHTG 44 WHERE OCCURS WEB STIFF. EN ✓ SEE PLAN FOR 1 4 APPROVED METAL HANGERS 7\ 4s"oc 1 s-r B.N.--,,� BY TRUSS M F PAY ONLY TJI PER PLAN FJ PER HARDY PANEL Zl- I 1 3/4" CRUSHING fE TO KING STUD WHERE 16� 2. CONIC. FTG, PER PLAN E. N. (PC OCCURS W/4-1/4"o x 1.IN. TOP AND BOT 0 STUCCO FIN. 7/8"o OR 1 1/8"o 1 1/4" HFS OR SDS WEEP SCREED------� :IT DF HOEDOWN ANCHORS L.N.NA.B. PER PLAN SCREWS (TYP.) REINF. PER Pt : PER SCHED. 6-(MIN.) . .1 NtG FG REBAR rPLYWOOD FLOOR 2x SILL SHT'G. X 2 ROWS 16d 18"NIN.) 1" NOSING 1STO 6*MIN SiMP A35F 2STORY 7�8 wl�N A 4" 0 C FULL BRG. LAP STAGG. . A I I - D {TYP. EA. eLK.) 12-MIN (1 STO T E & 2 OR 3X P,T.D.F. SIcn LL PLA MIN(2 STORY) - ----------- 18-MIN(2 STORY) PER PLAN z PLAN i! PER J A.B.FLOOR JOIST 16:' 0. C. E.N. \—TJI PER PLAN. T 7. 2 OR 3X STUD 8 PER PLAN 3"CLR SHEAR WALL LAP W/4-16d 31 *AT EXIST. FIGS. I w-U, F M —IN SHT'G. SEE PLAN @ 48"O/C MAX. USE REED -HEADS e TOP OF CONC., 2x P.T.D.F. 0 fI I SILL FE z TO M;�F& SILL LIN__(j STORY) STEM WALL DOUBLE 2x TOP PLATE BOLTING IOBO Ell jRi I N 2x STUDS (2 STORY) SILL TL_ A.B.w #1372 MIN, EMBER 4x BLK'G. UNDER— w ED T E 2 ANCHORS USE WEDGE PANEL OR 4x RIM 'ANCHORS 0 STRINGER 6 HEADERtt 2` MIN. ----- W/ l" NOSING t 1/2" 0 FOUNDATION/FLOOR F_ HARDY PANEL DETAIL A cc 0 37 33 29 21 w w �,IANDRAIL AS EXISTING. SLAB NEW SLAB m SELECTED BY SIIiPSON PHD, SEE PLAN --__, POST'' SCH P'"I N, (4x MON.) OUINER wl APRRVO 1. 12" SUF-PORTS TERMINATIWs L 10SON SDS 1/4' x 3", SEE 2110 L IN NEUr_-L OR cTn SCHEDULE SAFETY POST MIN. z p-voF sh-r A SIMPSON SSTB, SEE SCHEDULE— 4 A f--2x OR 3x PTDlF MIJI)SILL, SEE C)tp, . 0 N 1,-. R, Ft;�lz, ftA-d A A X SLAB 413 LNLWb 1 2- A e 52#11olc #4 REBAR z a. FOUNDATION H 9/16-MIN 0 4 BRILL uj e-, sv, DOWELS 0 7 HOLE FILL W/EPDXY L NO SPECIAL INSPECTION z GROUT & INSERT DOWE 24"O.C. w USE 1/2- IS REQ'D. FOR EPDXY IN f ALTERNATE. REDHEADS & THRD'D ROD THIS APPLICATION. AT SLABS CL REBAR DOWELS 0 tv, NOTE: CONCRETE STEM WALLS SHALL BE X95, 0- 6' WN WiDM FOR 5/8"9 ANCHORS 8` MIN WIDTH FOP 7/8.0 ANCHORS 8" MIN FOR CONC. BLOCK tf-, Al scram sake. rag._SD�3'-SD ^xD2 p SD5S3 PH06-S'!',3 PHM-SOS3 —i—OF SNP, slys ­ 1 1 13 2i s7R,l 1 POUR 20 SST8 23 — SS18 28 SSE 2. POUR SS18 24 s34 Im ss-m 34 Q N. DJ 2 34" ALLOWA, LOAL) M5 j 5,660 1 6,730 j DRILL SLANT HOLES EXIST"G 1/16- OVER DIA OF NEW SAME SIZE & SPACING AS < BAR FILL W/EPDXY 6. 24"MIN FOOTINGS GROUT z 0 A 4' A 'A A �A 2- 3/8" LAG SCREWS 0 AA 24" O.C. 14 w z :A 3: A OkA,eneikL�_ LOADS BASED ON MIN 4X POST SIZE OR -MAX, AT FOOTING SL faf;z rtAto s', v SG t ICU1 ANCHOR LOAD. DOWELS Z PHD w/ SDS HOEDOWNS 7- SCA! L HANDRAIL TIO WIT14STAND MIN. 29>00 LOAO IN ANY 0112ECTI0N 30 34 30 26 22 0 z WD,POST W/ SIMP 'HTT22' WITH SSTB24 I— n, 2X12 STRINGERS (MIN 3) - 4X4 POST MIN. �_ys w, PL, PLYWD TREADS RISERS (MIN 3/4") 0 W/ E.N. z FLR SHT`G. 2X F.J. 2X4 THRUST PLATE ANCHORED 3 Aft **PHD OR HD PER — PLANS & SIMPSON CATALOG EXISTING FOOTING 3: jJir4* L -P,T.D.F w SILL. 4 PLT GRDER/44�9 DRILL HOLES OD I.C.B.0 F-71 THREADED R t-�;& 1/16 LARGER W/ EPDXY n w THAN BOLT DIA. 4945 CITY OF L.A. MIN. AT EXIST. FLR. 4X4 PC IN Al 0 25185.W/ WHERE POSTS DO NOT LINE PBS4R.— USE EQUIVALENT SP. INSPECTION USE (ET22) U.N.0, ------- PHD w UP W/GIROERS 'v A - USE �x OR Bx STEM M BETW. JSTS. TO MATCH POST WIDTH & 2-A,35's EkEND - SEE a BE W BLK,\ co C14 - ----- - Ir a REINF W/ HDA OR E30 LT (IN.) EDGE (IN.) W (N.) EMBEDMENT (I N.) Ab�r E ILE CL COMPRESSION tc 2000 OEM) 1" NOSIN 2 0 uj 11 it 3 z 417 161 1 HD 2A 5/8 1 12 2775 HD5A 5/8 1-3/4- 6 12 4010 HOE 15 1 5100, 7460 0" z 2-#4 E/w. USE SIMPSON SET EPDXY ICSO #ER5279 OR R.R. #25279 SEE PLAN Tt NOTE: FOR RAISED FLOOR USE LONGER E30LTS TO EXTEND ABOVE FLOOR SHEATHING cr -�T._USE PREFAB PIERS EMBED 2' POST INTO CONC. PAD IN LIEU OF CONIC. STEM ILL STRINGER 0 FLOOR HOLDOWN, TO EXIST. FOOTING W/ 1"NOSING A/2" ll'- 0 SEE PLAN 'FOR SIZE CONCRETE PIER AND REINFORCING I t 39 35 31 27 23 c c SEE SCHED. FOR LENGTH 1/4"o x 4 1/2', HFS OR SDS SCREWS Ll PER SCHED. :2 "HARDY FRAME" SEE PLAN FOR r KING STUD MODEL NO. I 1 /-WHERE OCCURS a u Is sr c 7/8"0 EPDXY I FSCREW KING STUD 4 BOLTS - EMBED t I 4x BLK'G. i 1 WHERE OCCURS TO c -EXISTING FOOTING 15" INTO WALL UNDER PANEL HARDY FRAME W/4- a I FTG. W/SPEC. I i OR 4x RI #10 x 2 1/2- C SCREWS INSP. PER ICBO (TYP.) 2 NEW UNDERPIN #ER5279, R.R. C 15, N z 11 -PLYWOOD FLOOR PER PLAN 4 f�z, -4 ru�l #25279 A I / SH lG_ 2x SILL C SIMP. A35F [L 0 16-0/c t C z A REINF PER to A PLAN FLOOR- , tI, z Y 1u JOIST y �4 .4 > CL A A A 9 ��,.` I 2x P.T.D.F. TOP OF SEE PLAN SILL Pt EXIST. CONC. J� STEM WALL EXIST. SILL fen Lu FOUNDATION UNDERPIN HARDY FRAME DETAIL 40 36 32 28 24 9_00-'s &f lei, ---------- PIREPARED BY: � -IZZA fT -F I N, Kxc,cL',' M 0 e 'c PH i714 / 8,351 1585 FX 714 / 855 1428 2017 W. ALCo AVE. SANTA ANA CALIFORNIA 92703 AAbRAFTING0MSN.COM REVISIONS f'Es 10 I. �\x 0� 0 43205 p. 3/31106 OF C SITE: ter, OWNER:, ..r?nA - .LOSE CERVANTES"011 Arc (714) 557 8949 Of, JOB DESCRIPTION: :44 l SO FT 2-STORY ADDI STRUCTURAL DETAILS DRAWN: AL CHECKED: DATE: JOB NO: AuG-04-04- 001-04 SHEET NUMBER: D _"". 2 GENERAL NOTES 1. EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN ON THE PLANS, WORKMANSHIP & MATERIALS SHALL CONFORM TO THE LATEST EDITION OF THE C.B.C., U.B.C. OR LOCAL CODE 2. THE PLANS SHALL BE REVIEWED FOR DIMENSIONAL & EXISTING SITE CONFORMANCE WITH THE PLANS BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. THE ARCHITECT & ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 3. WORKING DIMENSIONS SHALL NOT BE SCALED FROM DRAWINGS. 4, ITEMS IDENTIFIED BY TRADE NAMES MAY BE SUBSTITUTED BY APPROVED EQUALS. 5. NOTES & DETAILS ON DRAWINGS SHALL PRECEDE THESE GENERAL NOTES '„' •�a �*1E1 1. PROVIDE ANY SHORING & OR BRACING PRIOR TO REMOVING EXISTING WALLS, BEAMS, OR SUPPORTS FOR CONSTRUCTION. REMOVE SHORING ONLY WHEN NEW SUPPORTS ARE IN PLACE AND SECURED. 2. PROVIDE RED HEADS INTO EXISTING CONCRETE AT ALL SHEAR WALLS PER MFG. SPECIFICATIONS. SEE SHEAR WALL SCHEDULE FOR SIZE AND SPACING. 3, PROVIDE SIMPSON ST-6224 BETWEEN NEW WALLS AND EXISTING WALLS AT THE DOUBLE TOP PLATE. 4. THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES WHETHER OR NOT SHOWN ON DRAWINGS AND PROTECT THEM FROM DAMAGE. 5. DO NOT CUT POST TENSION SLABS, CONTRACTOR TO DETERMINE EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. 6. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS FOR FOOTINGS, BEAMS AND JOISTS, SIZES LOCATIONS ETC. AND SHALL NOTIFY THE ARCHITECT & ENGINEER OF ANY DISCREPANCIES. 7. DOWEL NEW INTO EXISTING SLABS W/#4 REBAR 0 24" O.C. AND FOOTINGS W/DOWELS TO MATCH NEW REINF. SIZE/LOCATION. ENGINEERING NOTES 1. CONCRETE SLABS ON GRADE HAVE NOT BEEN DESIGNED BY THE STRUCTURAL ENGINEER. 2. THE VIBRATIONAL EFFECTS OF MECHANICAL EQUIPMENT HAVE NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER. 3, THE DESIGN, ADEQUACY AND SAFETY OF ERECTION, BRACING SHORING, TEMPORARY SUPPORTS ETC., IS THE SOLE RESPONSIBLITY OF THE CONTRACTOR, AND HAS NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE DURING THE ENTIRE COURSE OF CONSTRUCTION. THE ENGINEER SHALL NOT BE HELD RESPONSIBLE FOR FIELD INSPECTION/OBSERVATION OF THE ABOVE ITEMS. 4. ALLOWABLE SOILS PRESSURE TO BE A MINIMUM OF 1000 PSF UNLESS A SOILS REPORT IS PROVIDED. SOILS iN THE BUILDING AREA & 5 FEET BEYOND SHALL BE COMPACTED TO A MINIMUM OF SOX RELATIVE COMPACTION PER U.B.C. SOILS REPORT BY: JOB NO. TRUCTURAL SYM 117 INDICATES SHEAR WALL TYPE & LENGTH. SEE FOUNDATION & OR FRAMING PLAN AND SHEAR WALL SCHEDULE FOR TYPE, SILL BOLTING, SHTG, ETC. NOTE: FOR SILL BOLTING AT EXISTING FOOTINGS USE "RED HEAD WEDGE ANCHORS" ICBO#1372 THE SAME SIZE & SPACING As SILL BOLTING (MIN 7 1/2" EMBED). INDICATES POST MIN. POST SIZE/TYPE AS FOLLOWS U.N.O,: BEAM SIZE POST SIZE 4 X 14 & SMALLER 2-20 W/16d NAILS 0 12" O.C, 6 X 12 & SMALLER 3-2X4 W/16d NAILS ® 12" O.C, 4 X 16 & LARGER 4X4 6 X 14 & LARGER 4X6 SEE HOLDOWN DETAILS AND TYPICAL WALL FRAMING FOR FURTHER POST SIZE REQUIREMENTS. POSTS ARE TO CONTINUE DOWN TO FOUNDATION. FOUNDATION NOTES GEN� 1. SOIL BENEATH FOOTINGS AND SLABS SHALL BE COMPACTED PER U.B.C. (90%) RELATIVE COMPACTION MINIMUM. 2. THE SOILS ENGINEER SHALL INSPECT THE FOUNDATION PRIOR TO POURING OF CONCRETE AND SHALL VERIFY THE SOiL BEARING PRESSURE TO BE /000 PSF MIN OR PER THE SOILS REPORT. 3. SLAB ON GRADE: 4 INCH. CONCRETE SLAB WITH #3 0 24"OjC E.W. 0 CENTER OF SLAB OVER 2 INCH. OF SAND OVER 6 MIL, VISQUEEN OVER COMPACTED SOILS U.N.D. 4. NO TRENCHES OR EXCAVATIONS FIVE FEET IN DEPTH OR GREATER INTO WHICH A PERSON SHALL BE REQUIRED TO DESCEND SHALL BE MADE WITHOUT PROPER PERMIT. 5. THE MINIMUM BOLTING FOR SILL PLATES TO FOUNDATION SHALL BE AS FOLLOWS: 5/8" DIAMETER ANCHOR BOLTS NTH 7" MIN EMBEDMENT IN CONCRETE WITH SPACING NO GREATOR THAN 4 FEET O.C. NOR FURTHER THAN 12" FROM CORNERS (MIN 2 BOLTS PER PIECE). SEE THE FOUNDATION PLAN & SHEAR WALL SCHEDULE FOR FURTHER BOLTING REQUIREMENTS 6. PIPES OR DUCTS THAT EXCEED ONE THIRD THE SLAB OR CONC. WALL THICKNESS SHALL NOT BE PLACED IN STRUCTURAL CONC. UNLESS SPECIFICALLY DETAILED. SEE MECHANICAL AND/OR ELECTRICAL DRAWINGS FOR LOCATION OF SLEEVES, ACCESSORIES, ETC. 7. PIPES MAY PASS THRU STRUCTURAL CONC. IN SLEEVES, BUT SHALL NOT BE EMBEDDED THEREIN. 8. PROVIDE 3/4" CAMBERS AT ALL EXPOSED CORNERS 9. SEE ARCHITECTURAL PLANS FOR MOLDS, GROOVES, ORNAMENTS CUPS OR GROUNDS REQUIRED TO BE CAST IN CONCRETE, AND FOR LOCATIONS OF FLOOR FINISHES AND SLAB DEPRESSIONS. 10. LOCATION OF POUR JOINTS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER. CONCRR 1. UNLESS OTHERWISE NOTED ON PLANS CONCRETE SHALL BE TYPE 1 WITH A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI IN 28 DAYS. CEMENT SHALL CONFORM TO A.S.T.M. CX-150 FINE & COURSE AGGREGATE SHALL CONFORM TO A.S.T.M. C33. REINFORCING STEEL 1. REINFORCING STEEL, #3 AND #4 GRADE 40, #5 AND LARGER -GRADE 60 PER A.S.T.M. A615. 2. LOW HYDROGEN WELDING RODS SHALL BE USED FOR ALL WELDING OF REINFORCING BARS. 3. BARS NOTED AS "CONT "TYPICAL WALL REINFORCING AND VERTICAL COLUMN REINFORCING SHALL HAVE A MINIMUM SPLICE OF 50 BAR DIAMETERS LAP IN MASONRY OR 40 BAR DIAMETERS MINIMUM IN CONCRETE.. 4. REINFORCING SHALL BE. SPLICED ONLY AS SHOWN OR NOTED. OTHER SPLICES SHALL BE APPROVED BY THE STRUCURAL ENGINEER. 5. SPLICES IN ADJACENT HORIZONTAL WALL REINFORCING BARS SHALL BE STAGGERED 4 FEET UNLESS OTHER WISE NOTED. 6. PROVIDE DOWELS IN FOOTINGS AND/OR GRADE BEAMS THE SAME SIZE AND NUMBER AS VERTICAL WALL OR COLUMN REINFORCING. DOWELS SHALL HAVE A MINIMUM PROJECTION EQUAL TO STANDARD LAP SPLICE UNLESS OTHERWISE NOTED, 7. ALL REINFORCING, ANCHOR BOLTS, AND OTHER INSERTS SHALL BE SECURED IN PLACE PRIOR TO PLACMENT OF CONCRETE OR GROUTING OF MASONRY. 8. PROVIDE THE FOLLOWING MINIMUM PROTECTIVE COVERING OF CONCRETE: BELOW GRADE (UNFORMED) ------------------------ 3" CLEAR BELOW GRADE (FORMED) -------------------------- 2" CLEAR WALLS-------------------------------------- 1" CLEAR COLUMNS ------------------------------------ 1.V'CLEAR BEAMS AND GIRDERS ----------------------------- 1.5"CLEAR STRUCTURAL SLAB (ABOVE GRADE) -------------------- 3/4"CLEAR 9. NUMBER 5 OR LARGER REINFORCING BARS SHALL NOT BE RE -BENT WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER. CONCRETE BLOCK MASONRY NAILING SCHEDULE (PER TABLE 23-II-B-1) 1. CONCRETE BLOCK SHALL CONFORM TO AS.T.M. C90, GRADE N UNITS. SEE THIS NAILING IS TYPICAL UNLESS OTHERWISE NOTED NAILS SHALL BE BOX OR ARCHITECTURAL PLANS FOR TYPE, PATTERN AND JOINT DETAILS. COMMON WiRE SPECiFICLY DETAILED CONNECTIONS SHALL BE NAILED WITH COMMON WORE NAILS. DIAPHRAGM SHEATHING NAILS OR OTHER APPROVED SHEATHING 2. MORTAR SHALL BE AS FOLLOWS: f'm = 1500 PSi MIN. CONNECTIONS SHALL BE DRIVEN . SO THAT THEIR HEAD OR CROWN IS FLUSH WITH 1 PART PORTLAND CEMENT 4 PARTS SAND 1/4 MIN, TO 1/2 MAX. PART HYDRATED THE SURFACE OF THE SHEATHING. ° - LiME JOISTS OR RAFTERS TO SIDES OR STUDS 3. GROUT SHALL BE AS FOLLOWS: Vc = 2500 PSI 8 INCHES IN DEPTH OR LESS ----------------------------- 3-16d 1 PART PORTLAND CEMENT 3 PARTS SAND 2 PARTS PEA GRAVEL WATER SUFFICIENT FOR EACH ADDITIONAL 4"DEPTH ADD ------------------------ 1-16d TO ALLOW GROUT TO FLOW INTO ALL JOINTS, JOISTS OR RAFTERS AT ALL BEARING I - #5 MIN. TOE NAiL EACH SIDE ----------------------------------- 3-8d 4. CELLS SHALL BE IN VERTICAL ALIGNMENT TO PROVIDE A MIN. UNOBSTRUCTED STUDS TO BEARING -TOE NAILS EA. SIDE--------------------2-8d CORE OF 3"X 3". DOWELS FROM FOOTINGS SHALL BE SET TO ALIGN WITH CORE BLOCKING BETWEEN JOISTS/RAFTERS REINFORCING. TO THE JOISTS/RAFTERS TOE NAILS EA SIDE ------------------- 2-10d a FROM BLOCKING TO BEARING TOE NAILS EA SIDE --•---------------2-10d 5. ALL CELLS BELOW FINISHED GRADE AND ALL CELLS WiTH REINFORCING, BLOCKING BETWEEN STUDS ° ANCHORS OR INSERTS SHALL BE F€LLED SOLID WITH GROUT. AT EACH END -TOE NAILS -------------------------------- 2-10d ENDNAILS ----------------------------------------- 2-16d 6. CONCRETE SURFACES SHALL BE CLEANED OF ALL LAITANCE PRIOR TO SETTING OF PROGRESSIVE BLOCKING r BLOCKS. RAFTER TO BLOCK & BLOCK TO CONT. NAILER --- ---------------•2-16d MULTIPLE STUDS 2- #5 Mi . FRAMING NOTES RIBBON O STUDS (STAGGER NAILS N STUDS WIDER THAN 4")-----•---------------6d824"OC 1 X RIBBON ------------------------------------------ 2-8d FRAMING SHALL COMPLY WITH SECTION 2320 OF THE U.B.C. LATEST EDITION. 2X RIBBON ---------------------------------------- 2-16d DOUBLE TOP PLATES SINGLE LAYER ERAMI ,G-00ERAL LOWER PLATE TO STUD -------------------------------- 2-16d UPPER TO LOWER PLATE ----------------------------- 16d@16"00 NOTE: "L" = 40 X BAR DIAMETER IN CONCRETE, U.N.O. 1. USE SIMPSON U-HANGERS ON ALL JOIST/BEAM/BEAM CONNECTIONS UNLESS AT SPLICES (48-MIN) ON EACH SIDE "L" = 50 X BAR DIAMETER IN MASONRY, U.N.O. NOTED ON PLANS. OF BUTT IN TOP PLATE --------------------------------- 8-16d UPPER TO LOWER PLATE 2. ALL POSTS SHALL HAVE SIMPSON "PC" CONNECTORS AT TOP AND SIMPSON "SC" AT INTERSECTIONS ----------------------------------- 8-i6d OR "BCD" CONNECTORS AT BASES UNLESS OTHERWISE NOTED ON PLANS. CEILING STRIPS REINFORCING 1 X4 PER BEARING(STRONGHOLD TYPE) -----•-------------------3-8d 3. ALL CONNECTING HARDWARE, JOIST HANGERS, TiE STRAPS ETC. SHALL BE 2X3 PER BEARING(STRONGHOLD TYPE)---------------------1-16d SIMPSON "STONG-TIE" UNLESS OTHERWISE NOTED OR SHOWN ON PLANS. PLYWOOD NAILNG{SEE DETAILS &/OR SCHEDULES BUILT UP BEAMS 2OdO32"OC AT TOP AND BOTTOM FRAMING -WALL STAGGERED ------------------------------------ 2-20d o END 1. SIZE, SPACING & HEIGHT LIMITS FOR WOOD STUDS ARE AS FOLLOWS (UNLESS 1X6 LET -IN BRACES, EACH BEARING .----------------------------2-8d OTHERWISE NOTED ON PLANS): (PRE ;DRILL HOLES FOR NAILS) 2X4 0 16"OC (BEARING WALL) SUPPORTING A MAXIMUM OF ONE FLOOR AND ONE ROOF SHALL HAVE A MAXIMUM HEIGHT OF 10 FEET 2X4 0 16"OC (NON -BEARING WALL) SHALL HAVE A MAXIMUM HEIGHT OF 14 FEET STRUCTURAL STEEL 2X6 0 16-OC (BEARING WALL) SUPPORTING A MAXIMUM OF TWO FLOORS AND A ROOF SHALL HAVE A MAXIMUM HEIGHT OF 10 FEET. 1. STRUCTURAL STEEL SHALL CONFORM TO STANDARD SPECIFiCAT(ON FOR REINFORCING SAME 2X6 0 16-OC (NON -BEARING WALL) MAXIMUM HEIGHT IS 20 FEET STRUCTURAL STEEL FOR BRIDGES OR BUILDINGS &S.T.M. A572 GRADE 50 OR DUAL SiZE AS FOOTING GRADE STEEL. REINFORCING 2. RAKE WALLS ADDACENT TO SLOPED CEILINGS SHALL BE BALLOON FRAMED. DOUBLE TOP PLATES SHALL ALWAYS BE SUPPOORTED BY A ROOF OR CEILING DIAPHRAM. 2, FABRICATION SHALL COMPLY WITH THE LATEST A.I.S.C. SPECS. 6' ,MIN, •• �, 3. SHEAR WALL PANELS MUST BE CONTINUOUS TO THE TOP PLATE AT ROOF 3. ALL BOLTS FOR STEEL MEMBERS SHALL CONFORM TO A.S,TN. A-307 UNLESS ` FRAMING. SHEATHING SHALL HAVE ALL EDGES BLOCKED & THE APPROPRIATE SHEAR OTHERWISE NOTED. � TRANSFER THRU CEILING OR SOFFIT FRAMING. 4. HiGH TENSILE BOLTS WHERE INDICATED ON THE PLANS OR DETAILS SHALL BE THE - 4. BORING AND NOTCHING OF WALL STUDS SHALL BE PER UBC (2320.11.9 & .10) FRICTION TYPE AND THERE SHALL BE NO PAINT, OIL, LAQUER OR GALVANIZING • NOTCHING MAX€MIUM: 25% OF WIDTH ON BEARING WALLS BETWEEN THE CONTACT SURFACES. HIGH TENSILE BOLTS SHALL CONFORM TO 4OX OF WIDTH ON NON -BEARING WALLS A.S.T.M. A-325 OR A-490. BORING MAXIMUM: 4O% OF WIDTH ON BEARING WALLS r°t 60% OF WIDTH ON NON -BEARING WALLS. 5. PIPE COLUMNS SHALL CONFORM TO A.S.T.M. A-53 GRADE B --- NOTE: A MiN 5/8"CLEARANCE FROM EDGE OF STUD TO HOLE SHALL BE PROVIDED. 6. STEEL TUBE SHAPED MEMBERS SHALL CONFORM TO A.S.T.M. A-501 OR A-500 3'-0" CONC. 5. DOUBLE 2X TOP PLATE SHALL BE LAPPED 48" AT ALL SPLICES AND SHALL GRADE B. 40 DiR e. 2 -8 MAS. 3" CLR. OVERLAP AT CORNERS. " 7, WHERE FINISH IS ATTACHED TO STRUCTURAL STEEL, PROVIDE HOLES FOR 1/2 d 6. WALL BRACING SHALL BE PROVIDED PER UBC (2320.5.1) PROVIDE 1X6 LET -IN WELDED STUDS AT 4 FEET O.C. FOR THE ATTACHMENT OF NAILERS. SEE BRACING (o APPROX. 45 DEGREES) EVERY 25' IN ALL STUD WALL NOT ARHITECTURAL DRAWINGS FOR FINISHES. SHEATHED.SRACES TO RUN CONTINUOUS FROM TOP PLATE TO SiLL PLATE. 8. BEAM CONNECTIONS SHALLCOMPLY WITH 'FRAMED BEAM CONNECTIONS" A.I.S.G, STEPPED FC)O ®TING FLAMING -FLOOR PART 4, TABU 1, USING 3/4" DIA. A307 BOLTS (M.S.). 1. FLOOR SHEATHING (MIN) 3/4" STRUCTURAL i T & G PLYWOOD PANEL INDEX NO. . OPEN WEB JOISTS SHALL. COMPLY WITH THE STANDARDS OF "THE STEEL JOIST 32/16 OR MATCH EXISTING WITH EXTERIOR GLUE. USE 10d NAILS AT 6 OC AT ALL EDGES, BOUNDARIES, SHEARWALLS & 10"OC FIELD. NO BLOCKING IS REQUIRED T• EEL LNELDIL4 UNLESS NOTED ON PLAN, ALL EDGES BLOCKED AT DECKS. 2. PROVIDE DOUBLE FLOOR JOISTS UNDER ALL PARALLEL NON -BEARING PARTiT€ONS. 1. WELDIN BE DONE BY THE ELECTRIC SHIELDED ARC P SS AND SHALL COMPLY WITH A. ECIFICATIONS FOR WELDING AND FAB ON. 3. PROVIDE CONTINUOUS BLOCKING BETWEEN FLOOR JOISTS UNDER BEARING WALLS WHICH ARE PERPENDICULAR TO JOISTS. 2. WELDING SHALL BE PERFO Y CERTIFIED W WHO ARE APPROVED BY THE LOCAL AUTHORITY. 4. FRAMING AROUND OPENINGS: TRIMMER AND HEADER JOISTS SHALL BE DOUBLED AND SUPPORTED BY HANGERS PER CODE {UBC 2320,8.4). 3. ALL FIELD WELDS SHALL HAVE CONTI S € ON PER UBC (1701.5.5) UNLESS OTHERW€SE NOTED. FRAMING; ROOF 4. ALL BUTT WELDS SHALL ULL PENETRATION U.N.O. 1. ROOF SHEATHING (MIN) 1/2" STANDARD PLYWOOD PANEL INDEX NO. 24/0 WITH EXTERIOR GLUE. USE 8d NAILS AT 6-OC AT ALL EDGES, BOUNDARIES AND SHEAR 0 CATION FROM THE SHOP PERFORMING WELDING OR A 5. A CERTIFICATE RICATION WALLS & 12" OC FIELD. NO BLOCKING i5 REQUIRED UNLESS NOTED ON PLAN. REPORT FROM PECIRI MUST BE FURNISHED TO THE JOB INSPECTOR PRIOR TO F G APPROVAL. 2. FRAMING AROUND OPENINGS: TRIMMER AND HEADER JOISTS SHAD. BE DOUBLED 6. E7018 ELECTRODE W/201-} TOUGHNESS FACTOR. AND SUPPORTED BY HANGERS PER CODE. - {PER TABLE 23-1V-J-3} IN UOTTES 1. CEILING JOISTS SHALL BE 2X6 016"O.C. (MAX SPAN=15'-9") 1. A GRADIN SHALL BE OBTAINED PRIOR TO ANY G. 2. CEILING JOISTS SHALL BE 2X8 o16"O,C. {MAX SPAN-20'-9°) 2. ALL FILL ONE FOOT & G HALL FLED AND TESTED AS TO RELATIVE COMPACTION PER U.B.C. ,, ER6MINQ-JQj T'/B6U 3. ALL FILL SHALL BE TEED IN ACCORDANCE HAPTER 70 OF THE 1. BORING AND NOTCHING OF JOISTS SHALL BE AS FOLLOWS: LATEST ADOPT N OF THE U.B.C. 4, ALL UTILITY TR �KFILLS SHALL BE IN ACC WITH THE SOILS ENGINEERS RECOMMENDATIONS. {UBC 2.4) BORING -MAX. DIA. OF HOLE SHALL NOT EXCEED 1/3 OF DRESSED DEPTH OF JOIST DRAINAGE NOTE WITH A MINIMUM EDGE CLEARANCE OF TWO INCHES. NOTCHING -MAX. DEPTH AT ENDS SHALL NOT EXCEED 1 /4 OF DRESSED DEPTH. NO NOTCHING IS ALLOWED iN THE 1. MINIMUM GRADIENTS ARE AS FOLLOWS: EARTH= 1 % PAVING=.5% CENTER THIRD OF THE JOIST SPAN. NOTCHING IN OTHER LOCATIONS SHALL BE ON THE COMPRESSIVE SIDE WITH A MAX DEPTH OF 1/6 OF THE JOIST DEPTH. 2. POSITIVE DRAINAGE AWAY FROM STRUCTURES SHALL BE AS FOLLOWS: 2% MIN TO 217o MAX SWALES TO BE 3 FEET MIN AWAY FROM STRUCTURES. 2. WHERE THREE OR MORE (MULTI JOISTS) ARE USED THE JOISTS SHALL BE BOLTED TOGETHER WITH 1 /2"DIA MACHINE BOLTS W/ WASHERS AT 24"OC STAGGERED. BOLTS SHALL BE RETiGHTENED PRIOR TO APPLYING FINISH MATERIALS. 3. JOISTS/RAFTERS SHALL LAP AT SPLICES A MIN. OF 4 INCHES WITH 3-16d NAILS OR USE SIMPSON ST 2115 0 48 INCHES D.C. 4. CROSS BRIDGING OR 2X BLKG.SHALL BE PROVIDED 0 8'-0" O/C, MAX, FOR ALL JOISTS AND RAFTERS MORE THAN 8" IN DEPTH 5. 2X SOLID BLOCKING SHALL BE PLACED BETWEEN JOISTS OR RAFTERS AT ALL SUPPORTS. 2X STUDS 16" O.C. FRAMING -BOLTING 16d o 12" O.C., 1. ALL BOLTS BEARING ON WOOD SHALL HAVE WASHERS UNDER HEAD OR NUT, SEE STAGGERED PLYWOOD SCHEDULE 16d o 12" O.C, OCiUR5 16d PER E.N. STAGGERED AF SHEAR WALLS 2. ALL BOLTS SHALL BE RETIGHTENED, PRIOR TO APPLICATION OF PLYWOOD, PLASTER ETC. 3. HOLES FOR BOLTS SHALL BE BORED 1/32" TO 1/16" LARGER THAN NOMINAL BOLT DIAMETER. Lums 12" I.G. BLOCKING o TOP, POST WHERE BOTTOM, & MID -HEIGHT OCCURS 1. ALL LUMBER SHALL BE DOUGLAS FIR OF THE FOLLOWING GRADES UNLESS OTHERWISE NOTED (MAX MOISTURE CONTENT SHALT. NOT EXCEED i 9% & GRADED IN ACCORDANCE WITH THE WEST COAST LUMBERMANS ASSOCIATION.) TYP. STUD WALL INTERSECTIONS BIRESE MEMBERS i STUDS & PLATES --------------------------------- --NO.2. JOISTS & RAFTERS 20 TO 04 INCLUSIVE ------------------------------ NO.2 2X6 TO 3X16 INCLUSIVE ----------------------------- NO.2 BEAMS V5F M FRS FOR SIZE AND SPACING OF -STAGGER PLYWOOD JOINTS JOIST OR RAFTER, SEE PLAN 4X------------------------------------------- NO.2 3/8" MIN. EDGE DISTANCE 6X OR LARGER ------------------------------------ NO.1 BOUNDARY NAILING (B.N.) FOR AILS POSTS & MULLIONS ALONG CONTINUOUS 4X4 & SMALLER ----------------------------------- NO.2 PANEL EDGES 4X6 & LARGER ------------------------------------ NO.2 6X6 & LARGER ------------------------------------ NOA MISCELLANEOUS LUMBER BLOCKING,FURRING, ETC .------------------•------------NO.3 DECKING & SHEATHING TYPICAL INTERMEDIATE 2X,3X,4X----------------------------------- COMM'L DEX. NAIUNG (I.N.) FLOORS-10d o 10" D.C. 2. ALL WOOD BEARING ON CONCRETE OR MASONRY IF LESS THAN 4 FEET FROM ROOFS- 10d iA 12" O.G.- GRADE SHALL BE PRESSURE TREATED DOUG FIR. 3. GLUED -LAMINATED WOOD BEAMS SHALL BE DOUGLAS FIR COMB. 24F-V8(k) DF/DF EDGE NAILING (E.N.) (Fb•240OPSi, Fv=165 PSI, E-180,000 PSI) INDUSTRIAL APPEARANCE WITH EXTERIOR GLUE UNLESS OTHERWISE NOTED ON PLANS. A CERTIFICATE OF INSPECTION FOR EACH GLU-LAM BEAM FROM AN APPROVED TESTING AGENCY TO BE SUBMITTED AND 2 X 3 FLAT BLKG. AT APPROVED BY THE BUILDING DEPT. PRIOR TO ERECTION. [(•) USE V8 FOR CANT. UNSUPPORTED EDGES. (REO'D. -LON TO DIMENSION OF PLYWOOD RUN PERPINOICULAR TO BEAMS AND -V4 FOR- SIMPLE SPANS BEAMS] ONLY WHEN CALLED FOR ON JOISTS PLANS) 4. ALL STRUCTURAL PLYWOOD SHALL BE IN ACCORDANCE WITH P.S. 1-.iCp NOTE: PLYWOOD TO BE -MIN. SHEATHING SIZE TO BE 2°-O" X 4'-O" INSPECTED PRIOR TO COVERING PLYWOOD LAYOUT M _ M FRAMING ANCHOR TOP AND BOTTOM OF DOUBLE STUD OR POST - 40 DIA. NOTES: 1. ALL PIPE SLEEVES TO BE 2" LARGER THAN PIPE. 2. FOR PIPES MORE THAN 3'-0" BELOW BOTTOM OF FOOTINGS, STEP FOOTINGS PER DETAIL (NO PIPES ALLOWED IN FTG. STEP) 3. PLACE CONC, FILL AROUND SLEEVES BEFORE POURING FTG. PROVIDE 2" CEMENT DRYPACK IF PLACED UNDER-, i" EXIST. FTG,n PIPE SLEEVE DIAMETER PIPE TRENCH 17 z cn 40 'D' CONCRETE 14 50 'D' MASONRY ih PROVIDE SLEEVES FOR ALL PIPES, -- TRENCH SHALL NOT UNDERMINE WALL FTG. 507o COMPACTED BACKFILL 0 TRENCH EXCAVATION [-NO TRENCH PARALLEL TO FOOTING BELOW THIS LINE 1'-6" Mt . NO SLEEVES SHALL PENETRATE FOOTING "R" BAR SIZES 5 'D' #6, #7, #8 7 'D° #9, #fO, #f 1 w Jw1 /1� iC9 bC STRAP PER PLAN W/ 2X4 STUDS 0 FULL LENGTH NAILS 16" O.C. U.N.1 4'-0'° MIN. LAP r- DOUBLE TOP PLATES 1 HEADER --✓ 2X BLKG. 2X TRIMMER-- U.N.O. 4'-0" MIN. LAP 4X END POST- & HOLDOWNS DOUBLE TOP P TES ---7 € U.N.O. W/ E,N. TYP. 8 - 16d EA. SIDE OF TOP PLATE SPLICE U.N.O. ON FRAMING PLAN 2-2x PLATES, SEE PLANS FOR SIZE AND REFERENCE TO SPICES FOR HEADER SIZE, SEE PLAN 2x CRIPPLES AT 16" O.C. --:;,,r FIRE BLOCKING AT CEILING N._.- PROVIDE SiMPSON A34 FOR 2x4 LINE AND NOT TO EXCEED STUDS AND A35 FOR 2x6 STUDS, W-0" O.C. EACH SIDE NOTES FOR NAIUNG SEE GENERAL F--- USE 2-2x JAMBS FOR 4xt0 AND 6x8 AND LARGER HEADERS i STUD FOR INTERIOR WALLS END POST AT PLYWOOD SHEAR 2 STUDS FOR EXTERIOR PANEL WHERE OCCURS W/ E.N. UNLESS NOTED OTHERWISE NOTE Ill STUDS SHOWN ARE FOR INDICATION ONLY. ACTUAL LOCATION TO SUiT CONSTRUCTION REQUIREMENTS, MAX. SPACING AT 16" O.C. TYP. WALL FRAM I N G 2- 16d 16d 0 12", STAGGERED JOIST OR RAFTER UPPER PLATE 4" WIDER THAN LOWER PLATE 2X STUDS o 16" O.C. 19 12", STAGGERED OR RAFTER R PLATE 4" WIDER THAN R PLATE TUDS o 16" O.C. HOLDOWN PER 1 t 6'" M.IP3" SHEAR PANEL LENGTH r----- DOUBLE PLATE NOTES: /Bd MAX. 1. BORED HOLE & NOTCH SHALL NOT OCCUR IN SAME SECTION. 2. NOTCHES SHALL NOT OCCUR IN MIDDLE 1/3 OF SPAN. TYP. JOIST NOTCHING d WIDTH 101 d WIDTH lt� NOTCH IN STUD 2 d M , BORED HOLE 40 NOTE: BORED HOLE & NOTCH SHALL NOT 5 "MIN. OCCUR IN SAME . SECTION NON -BEARING PARTITION ^1"l/f'1 t'�'P'! i 1"1 R i 1"\•7'I"S 6 i 1 A i Pe aWAALL F OF STU 16d AT 12" EA. SIDE/ FA. CRiPF SILL PLATE BOLTING (OR NOTES: SOLE PLATE NAILING AT 1. WHERE BEAM INTERCEPTS TOP PLATE UPPER FLOORS) SPLICE USE ST6236 HEIGHT E D OSTUUDSS FULL WAU (4) 16d EA, SIDE 2X STUDS 16" O.C. qb (2) 2X CRIPPLES TYP. o BEAM OVER 8" DEPTH. USE 4X POST U.N.O. ON PLANS (CRIPPLE OR POST TO BE FULL MOTH ON SM.) 2. SM). W AN SIT C OON R P � PLATE ABOVE f : TYP. BEAM TO WALL SHEAR WALL SCHEDULE 1997 U.B.0 SILL BOLTING MARK WALL TYPE SHEAR 0 SHEAR ® ALLOWABLE ONE SIDE BOTH SIDES SILL NAILING SHEAR OF WALL OF WALL UPPER STORIES 7/8"STUCCO OVER PAPER BACKED LATH W/16 GA STAPLES AT 6"O.C. AT TOP .& BOTTOM A8PLATES, EDGE OF SHEAR WALL AND ON FIELD (ICBO REPORT No.1318, AUG. 2002) OR 180 PLF 5/8"055 o.C. 5/s"O27 1/2•oc 16d 0 8"O.C. (ICBO REPORT No>1254, MAR 1990) NOTE 4 AND 9 BELOW A 3 -P YWD 11 OR SM SHTG WITH& 8d1 NAILS 6"O.C. AT EDGES & 12" O.C. FIELD 260 PLF "� 5/s wo.c. 5/a ot9"o.c. 16d 0 6"O.C. L. a iSTRUC U , 10 SLOW BC) NOTE 3/8-PLYWD STRUCT it OR STD SHTG WITH 8d NAILS 0 4-O.C. AT EDGES & 12" O.C. FIELD 350 PLF 5/8"02600.C. 5/8"013o.C. 16d ® 4"O.C. 0 (TABLE 23-11-1-1 UBC) NOTE 1, 6, 9, 10 & 11 BELOW 3/8"PLYWD STRUCT If OR STD SHTG WITH 8d NAILS 0 4"O.C. AT EDGES & 12" O.C. FIELD 380 PLF 5/8"026"o.c. 5/a"owo.c. 16d 0 4"O.C. 11 (TABLE 23-11-1-1 UBC) NOTE 1, 3, 5, 6, 9, 10 & 11 BELOW A 3/8" PLYWD STRUCT 11 OR SM SHTG WiTH 8d NAILS 0 3" O.C. AT EDGES & 12" O.C. FIELD 490 PLF 5/a"o2o o.c. sjs oto"o.G. 16d 0 3 1/2"0.C. (TABLE 23-11-1-1 UBC) NOTE 1, 3, 5, 6, 9, 10 & 11 BELOW A3/8" PLYWD STRUCT 11 OR STD SHTG WITH 8d NAiLS 0 2" O.C. AT EDGES & 12" O.C. FIELD 610 PLF 5/a"a16"o.C. 5/s"os o.c. 16d 0 2 1/200.C. ABLE 23-11-1-1 UBC NOTE 1, 3, 5, 6, 9, 10 & 11 BELOW STRUCTWITH d N O.C. FIELD 2& $70 PLF 3%4"016"O.C. 3j4 QBo.C. N/A STUDSP(TABLE 23---11-1LYWD OVER 3X UBC)0NOT 3T 5,D6. 9,&10 1 1 BELOW NOTES: 1. ALL EDGES OF PLYWOOD SHEARWALLS MUST BE 5• FRAMING AT ADJOINING PANEL EDGES SHALL BE BLOCKED WITH 2X SOLID BLOCKING FOR WALL TYPES 3-INCH NOMINAL OR WIDER & NAILS SHALL BE 9 & 10, AND 3X SOLID BLOCKING FOR WALL TYPES STAGGERED, 11, 12. 13, & 14. 6. WHERE PLYWOOD IS APPLIED ON BOTH FACES OF A 2. WHERE SHEAR WALL SHEATHING IS TO BE APPLIED WALL AND NAiL SPACING IS LESS THAN 6 "O.0 ON TO BOTH SIDES IF WALL, DOUBLE THE NUMBER OF EITHER SiDE, PANEL JOINTS SHALL BE OFFSET TO FALL BOLTS. (I.E. HALF THE O/C SPACING) ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3-- INCHES NOMINAL OR THICKER & NAILS ON 3. USE 3X PRESSURE TREATED DOUGLAS FIR EACH SIDE SHALL BE STAGGERED, SILL PLATES AT FOUNDATION/FIRST FLOOR ONLY. 7. ALL CONTINUOUS EXTERIOR FOOTING TO HAVE 4. PAPER BACKED SELF FURRING EXPANDED METAL 5/L3" X 1O" A,B.'S 48"O.C. UNLESS OTHERWISE NOTED ON PLANS. LATH WITH iCSO APPROVAL 8. ALL INTERIOR BEARING AND NON BEARING FOOTINGS TO HAVE 7/32" SHOT PINS AT 32" O.C. & 48"O.C, RESPECTIVELY: I.E. HiLTI IC80 REPORT No.2388, NOV 1995 OR RAMSET/REDHEAD ICSO REPORT No.1639, DEC 1995 9. USE 2 1/2" x 2 1/2" x 3/16" PLATE WASHERS. 10. USE CDX. CC OR STD SHTG IN LIEU OF STRUCT 11 PLYWOOD. ALL PLYWOOD SHALL BE DOUGLAS FiR. OTHER SPECIES MAY REQUIRE CHANGES. 11. AT EXISTING FOOTINGS USE REDHEAD WEDGE ANCHORS TO COMPLY WITH SILL BOLTING. ICSO #1372 MIN. EMBED 7 ..t .i • sw i • � mr. mm mn momW, THIS SYSTEM MAY BE USED TO ANCHOR A HOT WATER HEATER THAT 15 ADJACENT TO � 1 A WALL. TANK NEED TO BE BOLTED TO THE 1 STUCCO o/ BLDG. FLOOR AND THE HEATER HOOKED UP WITH A PAPER o/ G.I. SREED 2 FLEXIBLE CsAS CONNECTION. w/ WEEP HOLES 2 SLAB INHERE OCCURS 3 P.T. D.F. SILL IF TANK HAS AN 4 CONC. SLAB 3 r '� '~ •, INSULATION BLANKET, 5 GRADE LEAVE IN PLACE 2 aa� 4 I { APPROVED STEEL STRAP Z SNU6xGL Y WRAPPED AROUND d TANK AND SNUG SPACER _ - �, -. PROVIDED BETWEEN THE �> gv> I CAP SHINGLES WATER HEATER AND WALL 2 ASPHALT SHINGLES ON 30 lb i If4" X 4 Ip2" LArs SCREW W® FELT ON DECKING PER STRUCTURAL WASHER TO 2X4 STUD OR BLK. PLANS ON ROOF RAFTERS PER PLANS 17 13 WATER HEATER BRACING WEEP SCREECH 3"-1'-O" � RIDGE 3"•1'-a" 1 4X4 TOP RAIL CUT TO RECEIVE CONTINUOUS TUBE 1 BLK'G Wt (3) - 2" DIA HOLES VW1 SREEN BACK'G WHERE OCCURS KEEP INSULATION CLEAR zx t x 0.074 CONTINUOUS TUBE 2 FIBERGLASS SHINGLES ON 30 lb FELT ON DECKING PER STRUCTURAL i'lz' X 1'/2'"X '/s" TUBE POST PLANS ON ROOF TRUSSES PER @ 26" O.C. WELDED TO TOP TUBE TRUSS PLANS _ 1" X VX 0.065 TUBES @ 4" O-C. 3. 2X6 RO.SO. FASCIA 00 4, STUCCO EXTERIOR O/ 2 O BLD`G PAPER 5 1X6 STARTER BOARD 1 �/2" X 1"X 0.074 CONTINUOUS -SHIPLAP AT EXPOSED EAVES .__.___..-.. .� TUBE BOT. RAIL 3f6" MG" X 5" X 3" STL PLATE (SEE BELOW) W/ 4-/y'" X 5" LONG LAG SCREWS 6 G.I. EDGE DRIP 7 INSULATION PER TITLE 24 EA. PLATE 8 STUD WALL PER PLANS -_ 9 i/2" GYP. BD. 2- 2X STAIR STRINGER + + OR FLOOR JOIST = 3 5 7 4 8 1 EAVE 1. BLDG. PAPER Ot G,l. 'WV' VALLEY FLASHING (2L') &.60 •t- IH) W/ CRIMPED EDGES 2. ROOFING. SEE ROOF PLAN 3. FRAM'G PER STRUCT, 2 1 3 19 15 VALLEY F LA. S H I N G 3 STUCCO U/ BLDG. , PAPER i ` G.I. FLASITYs ofTZ I X BLCK. BLOC. PAPER > !44, MTL CLSR STRIP OR MORTAL FILL 'S' TILE 20 16 12 8 ROOF TO WALL P9AEPAReED BY, �" 11 T 7-1 tV <::� I L aaf L t PH 1714 835 I585 Fx 714 1 835 1428 2017 W. ALco AVE. SANTA ANA } CALIFORNIA 92703 AADRAFTING@MSN. CQM i REVISIONS 3 } A } rc j'R"' ��'r •err � ��' "'° �. x c� ' 43205 [ P. 3/31 /06 y CiV1L�`t 7 T Cfi Cfi� 1Fa C SITE: C u L C L } i c c r u > 7 c u -n u u y_ J D L J z z n w d x D x :n h z m D 0 a a ua u� w z h z i h t"t z cc a 0 c� 0 U w JOB DESCRIPTION: U z 4 D- W Uj a z D ARCH ITCT' L 0 DETAILS a AS SHOWN 0 a a: z_ DRAWN: CHECKED: DATE: JOB NO: SHEET NUMBER: AD-1