Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10149812.pdf
W 0 IL IL ff IL (� W U) ; w � z C0 w CD Q w Q`0 Cr V Lj DISABLED ACCESSIBLE ENTRMCE� L._1.�..7 J lf0 ry 11336.3.1 ENTRANCES __...... .. ___.. ._._.__.._.. 1133B.1.1.1.fi _. _0 ALL ENTRANCES AND EXTERIOR GROUND -FLOOR EXiT DOORS TO BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TO PERSONS WITH DISABILITIES. DOORWAYS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 INCHES (818 MM) WITH THE DOOR OPEN 90 DEGREES, MEASURE BETWEEN THE FACE OF THE DOOR AND THE OPPOSITE STOP. OPENINGS MORE THAN 24 INCHES (610 Adak U MIA) IN DEPTH SHALL COMPLY WITH SECTIONS 1118B.1 AND 1118B.2. 3 1e E 11338.1.1.1.4 GATES. j L1 ALL GATES, INCLUDING TICKET GATES, SHALL MEET ALL APPLICABLE SPECIFICATIONS FOR DOORS. In \ 1133B.2.3.3 REVOLVING DOORS. Z"' REVOLVING DOORS SHALL NOT BE USED AS REQUIRED ENTRANCE FOR PERSONS WITH DISABILITIES, 0 10038.2.2 WIDTH AND HEIGHT. I EXHISET "Asa U In EVERY REQUIRED EXiT DOORWAY SHALL BE OF A SIZES TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3 FEET (914 MM) IN WIDTH AND NOT LESS THAN 6 FEET 8 INCHES (2032 MM) IN HEIGHT. WHEN INSTALLED IN EXIT DOORWAYS, EXIT DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE EXITWAY IS NOT LESS THAN 32 INCHES (813 MM). IN COMPUTING THE EXIT WIDTH REQUIRED BY SECTION 1003.2.3, THE NET DIMENSION OF THE EXITWAY SHALL BE USED. # i 40 1117B.5.7 ENTRANCE SIGNS. "'* General Notes ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PERSONS WITH DISABILITIES SHALL BE IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL ThiDIRECTIONAL SIGNS, AS REQUIRED, TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS. s3R " JM and plan and the designs herein are the oats property of *,q by anyone, in part notor reproduced, outchathe written or used written permission of sit "otions to this 11178.5.7 MOUNTING LOCATION AND HEIGHT. < w Plan pp writing r `— a atom tJM o read and Is the re fny officer, Any amiliar y o oil information using mown rrunst be approved � wrist b JM before such work is done. It is the resparrsibi dy of anyone using this MOUNTING HEIGHT SHALL BE 60 INCHES (1524 MM) ABOVE THE FINISH FLOOR TO THE CENTER LINE OF THE SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY 4i `� hereon hnfuding arty list of Hates. Measurements on this APPROACH WITHIN 3 INCHES (76 MIA) OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE DOOR. # pion are from avalable information, JM will not assume any responsibility for the accuracy of such information. Fabricators, contractors, etc, using this plan are to confirm 1133.B.2.6 SMOOTH SURFACE. ,, all information on this plan with the job site, All information Hv on this plan for the general contractor or the general con - THE BOTTOM 10 INCHES {254 MM} OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR 4 troctor's subcontractors to perform (plumbing, electrical, FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10-INCH 245 MM HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH of curbs, walls, buitd'eng openings, etc.) are for the sole purpose ( )r n of equipment requirements; reference is made to the owner ^^ a or architectural plans for angineering or listing of items not SIDE OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. suppS�l by JM. N will not assume o7 respon- 5 _. _ _. sbii'dy for engineering thereof. All buil 4 work thereof 11336.2.4.4 "^ ^ - - __ .. - shall ba by the general contractor including all roughing -in - and final connections and oil runs to equipment and in- cluding1H€ SPACE BETWEEN 1Yf0 CONSECUTIVE DOOR OPENINGS IN A VESTIBULE, SERVING OTHER THAN A REQUIRED EXIT STAIRWAY SHALL PROVIDE A MINIMUM OF 48 INCHES (1219 MM) OF CLEAR all fittings or any other pats materials or labor for such work, if any such work is in JM contract, it will SPACE FROM ANY DOOR OPENING INTO SUCH VESTIBULE WHEN THE DOOR IS POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. DOORS IN A SERIES SHALL. SWING specifically be indicated on this plan; if A is not specifically imficoted on this plan, it is not a part of JM contract EITHER iN THE SAME DIRECTION OR AWAY FROM THE SPACE BETWEEN THE DOORS. and shall be provided by others. JM will assume no c responsibility for work done by the general contractor or a 1133.82.5 CLOSER -EFFORT TO OPERATE DOORS. subcontractor of the general contractor or any changes made necessary by local codes (including: Building, Cith MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGL=S TO HINGED Depart. ordinances, Fire Depart., etc.) or changes by the s owner, omhW or any other person outside of JM with DOORS AND AT THE CENTER PLAN OF SLIDING OR FOLDING DOORS, COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FiRE �" rr authority to the design. This plan becomes void upon such err 7, - i ` ` . changes and work cannot be completed until the appropriate DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE AMINISTRATIVE AUTHORITY, NO TO EXCEED 15 r corrections ore mass byy Nil, using the Plan s admt- s tone that oil mformo'on on this plan has been examined POUNDS (66,72 N), t- and compared with other plans (example: architectural plans) and any Inconsistencies, errors, ambiguities or orits- �x stuns have been reported to JM for written corrections before completing bids or commencing any work hereunder. 1133B.24.1 THRESHOLDS. `'' # No additional allowance will be made far such work unless it is agreed before acceptance of bids. Plumbing or electricol THE FLOOR OR LANDING SHALL NOT BE MORE TAN 1/2 INCH (i2.7 MM) LOWER THAN THE THRESHOLD OF THE DOOR -WAY. CHANGE IN LEVEL BETWEEN INCH (6 MM) AD 1/2 INCH (12.1 MM) d parts not suppled with the equipment as a standard item shall be provided by the plumber or electrician unless SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL TO 2 UNITS HORIZONTAL (5(Yo SLOPE). CHANGE IN LEVEL GREATER THAN 1/2 INCH (12.7 MM) SHALL BE µ specifically indicated on this plan. ACCOMPLISHED BY MEANS OF A RAMP. rSUBWAY - rd 11338,2.5.2 DOOR HARDWARE HAND -ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30 INCHES (762 MM) AND 44 INCHES (1118 MM) ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE .� HAND AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER -TYPE HARDWARE, PANIC BARS, PUCH-PULL ACTIVATING BARS OR OTHER 1 ' � -MI-t° t A ffit 44 Vn HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. 11333.2.4 FLOOR LEVEL AT DOORS. REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE FLOOR OR LANDING ON EACH SIDE OF A DOOR. e L4 :Y f�: ugt rr _ ��5' "ss yp 1003.3.1.6 LANDINGS. r , LANDINGS SHALL BE LEVEL EXCEPT THAT EXTERIOR LANDINGS MAY HAVE A SLOPE NOT TO EXCEED 1/4 UNIT VERTICAL iN 12 UNiTS HORIZONTAL (2% SLOPE). I ! I' ) dkv> g' 1 "� 03-25-05 SUBMITTAL DOCUMENT z-•.....Y i z { tt' .. 1. _ 2R,,.�'.''d"` sr-atRr.y f a �,� % j 61 ��. .� 1133B.2.4.2 MANEUVERING CLEARANCES AT DOORS. �" ° " p���� d .,. '�" w;,ewe"......,....,9or�'teittR•x6A9fs4"i m'a+z<ru x .w� ' _ xo�ai�,,,.��+s, - .,� � t ACCEPTED �� �fitC-', RP,.VISIGh�I/IS$LIP. MINIMUM MANEUVERING CLEARANCES AT DOORS SHALL BE AS SHOWN IN FIGURE 118-26A AND 11B-268. THE FLOOR OR GROUND AREA WITHIN THE REQUIRED CLEARANCES SHALL BE LEVEL _ , , - r � �uww a � - ��... �+.«-,--..,....,.,�.......w.,.t»-,.,.x..-,n� .......�.:..:.r,kMt�:a.:: �et,.,::....,....,....•«...., ..-1:.7:4 .,w+cea�W.,.�.'..,.,��,:«.� .��o.....� .. ,.�: ,o�-,.,...,...�,w„w.mm".. �e�,�*..«x. ..,�- xwxiaEn+,.�.�.. � •�,.x� �-..,.4,,...... tk� $ <. AND CLEAR. THE LEVEL AREA SHALL HE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60 INCHES (1524 MM) AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF ti t 48INCHES (1219 MM) AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION.4� nTIj y� P-A"$) G 1 a ,-•• 6 erg CAL, u,uku ' '` ar€;x +� PLAq J . 4� � 4 ;� •��..a�,:,,,.�.. �) � a.a �) a� �rf w,aa�;lyTGaa€:�fT�a "�'�( L", 11338.2.4.3 ,. THE WIDTH OF THE LEVEL AREA OF THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND 24 INCHES (610 MM) PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18 INCHESLOoo ,. n stT f1 (r l ? r' 0 T" (0= ,$ f ¥ is s Oft Same wjd � � ,� � �� k�L1 ��� (457 MM) PAST THE STRIKE EDGE FOR EXTERIOR DOORS. y T m i f' I ,..,....wee. z a @ a Ana. �y R3 � at Santa E%9¢�eE� a'3�#:�aa k baays.Y t83 »o (}/pr/qp(�(f�/ sa i nCe DISABLED ACCESSIBLE PARKING r. ) . tf7� O(s �1g) x (, a S' �v ,'i t s a %$ 3 S g-� n 4 a Y _ _a SECTION 1129B-ACCESSIBLE PARKING SITE PLAN p ) ` f & r , a f yrT t ' NO"z J �.-� � � �� fT � I`jY (✓a € �=�s,r0 Qr 2Tia IYad3 ( 4i '� �f s fT y Via, Q a y L.�- d 11296,1 GENERAL. �. �" f ass n pled EACH LOT OR PARKING STRUCTURE WHERE PARKING IS PROVIDED FOR THE PUBLIC AS CLIENTS, GUESTS OR EMPLOYEES, SHALL PROVIDE ACCESSIBLE PARKING AS REQUIRED BY THIS SECTION. ACCESSIBLE PARKING SPACESfif, SERVING A PARTICULAR BUILDING SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE ENTRANCE. IN PARKING FACILITIES THAT DO NOT SERVE A �7 Dr- A $ �U PARTICULAR BUILDING, ACCESSIBLE PARKING SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE OF TRAVEL TO AN ACCESSIBLE PEDESTRIAN ENTRANCE OF THE PARKING FACILITY. IN BUILDINGS WITH MULTIPLE ACCESSIBLE ENTRANCES WITH ADJACENT PARKING, ACCESSIBLE PARKING SPACES SHALL BE DISPERSED AND LOCATED CLOSEST TO THE ACCESSIBLE ENTRANCES. —' 4 ^ < 11298.4 PARKING SPACE SIZE. j - ACCESSIBLE PARKING SPACES SHALL BE LOCATED AS NEAR AS PRACTICAL TO A PRIMARY ENTRANCE AND SHALL BE SIZED AS FOLLOWS:UZ DiMENENSIONS:' s s PROJECT SUMMARY �� WHERE SINGLE SPACES ARE PROVIDED, THEY SHALL BE 14 FEET (4267 MM) WIDE AND OUTLINED TO PROVIDE A 9-FOOT (2743 MM) PARKING AREA AND A 5-FOOT (1524 MM) LOADING AND UNLOADING ACCESS AISLE ON THE �,,, ..-�-�" PASSENGER SIDE OF THE VEHICLE. WHEN MORE THAN ONE SPACE IS PROVIDED iN LIEU OF PROVIDED A 14-FOOT WIDE (4267 MM) SPACE FOR EACH PARKING SPACE, TWO SPACES CAN BE PROVIDED WITHIN A 23-FOOT-WAD€ ,9�- fj 1 'I 7010 MM AREA LINED TO PROVED A 9-FOOT 2743 MM PARKING AREA ON EACH SIDE OF A 5-FOOT 1524 MM LOADING AND UNLOADING ACCESS AISLE IN THE CENTER. THE MINIMUM LENGTH OF EACH PARKING SPACE k A Z ` ° ~ ' " ' ` 'V"" t I I { } ( } { } � ��' � ADDRESS: 1701 E. MCFADDEN SANTA ANA CA 92745 SHALL BE 18 FEET (5486 MIA). THE WORDS NO PARKING SHALL BE PAINTED ON THE GROUND WITHIN EACH FIVE FOOT (1524 MM) LOADING AND UNLOADING ACCESS AISLE. THiS NOTICE SHALL BE PAINTED IN WHITE LETTERS a F �-y C NO LESS THAN 12 INCHES (154 MM) HIGH AND LOCATED SO THAT IT IS VISIBLE TO TRAFFIC ENFORCEMENT OFFICIALS. 55 CONSTRUCTION TYPE: V -NON-SPRINKLER VAN SPACES(S). OCCUPANCY. B ONE IN EVERY EIGHT ACCESSIBLE SPACES„ BUT NOT LESS THAN ONE, SHALL BE SERVED BY AN ACCESS AISLE 96 INCHES {2438 MM} WiDE MINIMUM AND SHALL BE DESIGNATED VAN ACCESSIBLE AS REQUIRED BY SECTION �.,s.T_�.� e„ err,, .,�_.� _... .�, 1129B.5. ALL SUCH SPACES MAY BE GROUPED ON ONE LEVEL OF A PARKING STRUCTURE. THE WORDS NO PARKING SHALL BE PAINTED ON THE GROUND WITHIN EACH EIGHT -FOOT (1524 MM) LOADING AND UNLOADING AREA OF CONSTRUCTION: 1279 Sty. FT. ACCESS AISLE. THIS NOTICE SHALL BE PAINTED IN WHITE ACCESS AISLE. THiS NOTICE SHALL BE PAINTED IN WHITE LETTERS NO LESS THAN 12 INCHES (154 MM) HIGH AND LOCATED SO THAT IT IS VISIBLE TO TRAFFIC DINING: 630 SO. FT. ENFORCEMENT OFFICIALS. 1 . SURFACE SLOPES OF ACCESSIBLE PARKING SPACES SHALL BE THE MINIMUM POSSIBLE AND SHALL NOT EXCEED 1 UNIT VERTICAL TO 50 UNiTS HORIZONTAL (2 % SLOPE) IN ANY DIRECTION. APPLICABLE CODE: 2001 CBC 1129B.5 IDENTIFICATION OF PARKING SPACES FOR OFF-STREET PARKING FACILITIES. EACH PARKING SPACE RESERVED FOR PERSONS WITH DISABILITIES SHALL BE IDENTIFIED BY A REFLECTOR ZED SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON DARK BLUE BACKGROUND, THE SIGN SHALL NOT BE "",s RK m SUBWAY c � s �. SMALLER THAN 70 SQUARE INCHES (4516 MM2) IN AN AREA AND, WHEN IN A PATH OF TRAVEL, SHALL BE POSTED AT A MINIMUM HEIGHT OF 80 INCHES (2032 MM) FROM THE BOTTOM OF THE SIGN TO THE PARKING SPACE 1701 E. MCFADDEN PROJECT DESCRIPTION: TENANT IMPROVEMENT FOR RETAIL FOOD FINISHED GRADE. SIGNS MAY ALSO BE CENTERED ON A WALL AT THE INTERIOR END OF THE PARKING SPACE AT A MINIMUM HEIGHT OF 36 INCHES 914 MM FROM THE PARKING SPACE FINISHED GRADE, GROUND OR 1.s # e 4 SANTA ANA, CA ( } OCCUPANCY PERMIT # SIDEWALK. SPACES COMPLYING WITH SECTION 11298.4. ITEM 2 SHALL HAVE AN ADDITIONAL SIGN STATING "VAN -ACCESSIBLE" MOUNTED BELOW THE SYMBOL OF ACCESSIBILITY. '.? yes �n G.. ..,..... u,r M .,�... 2 4 AN ADDITIONAL SIGN SHALL ALSO BE POSTED IN A CONSPICUOUS PLACE AT EACH ENTRANCE TO OFF-STREET PARKING FACILITIES, OR IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE. THE SIGN McFAD EN y I r 4 SHALL NOT BE LESS THAN 17 INCHES BY 22 INCHES (432 MM BY 559 MM) IN HEIGHT, WHICH CLEARLY AND CONSPICUOUSLY STATES THE FOLLOWING: "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES " s s Y I � � ; �q ,°, OWNER: ALAN MAKOUI" 5 is, ,,ti NOT DISPLAYING DISTINGUISHING PLACARDS OR LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES MAY BE TOWED AWAY AT OWNER'S EXPENSE. TOWED VEHICLES MAYBE RECLAIMED BY TELEPHONING THE SANTA -- 1701 E. MCFADDEN ANA POLICE DEPT. At 714 245-8665. CVC 2265$A." iN ADDITION TO THE ABOVE REQUIREMENTS, THE SURFACE OF EACH ACCESSIBLE PARKING SPACE STALL SHALL HAVE A SURFACE IDENTIFICATION DUPLICATING EITHER OF THE FOLLOWINGSCHEMES: J'`ds-J Olt t'T sTtt'iC'T3s or modifications. EDINGER W 1. BY OUTLINED OR PAINTING THE STALL OR SPACE IN BLUE AND OUTLINING ON THE GROUND IN THE STALL OR SPACE IN SITE OR SUITABLE CONTRASTING COLOR A PROFILE 'VIEW DEPICTING A WHEELCHAIR NTH OCCUPANT; OR CONTRACTOR: B-4 CONSTRUCTION SERVICES f n � 2. BY OUTLINING A PROFILE ViEW OF A WHEELCHAIR NTH OCCUPANT IN WHITE ON BLUE BACKGROUND, THE PROFILE VIEW SHALL BE LOCATED SO THAT IT IS VISIBLE TO A TRAFFIC ENFORCEMENT OFFICER WHEN VEHICLE AP F{ BRYAN CHADDIGK -OWNER J ry W IS PROPERLY PARKED IN THE SPACE AND SHALL BE 36 INCHES HIGH BY 36 INCHES 'WIDE (914 MM BY 914 MM), /f '` to CSLB 709358 �y Z ARRANGEMENT OF PARKING SPACE. Fire Department Notes: % Fire Department final inspection required. Schedule all inspections 72 hours in advance b Gatlin 714-647-5700. Address Suite number shall be at least six(6) Inches high, and be 547 S. LAUREL AVE. _ "'x !N EACH PARKING AREA, A BUMPER OR CURB SHALL B€ PROVIDED AND LOCATED TO PREVENT ENCROACHMENT OF CARS OVER THE REQUIRED WIDTH OF WALKWAYS. ALSO, THE SPACE SHALL BE SO LOCATED THAT PERSON P p eq � P Y 9 � (} 9 , .. ,�,,,,.,_. rn uy WITH DISABILITIES ARE NOT COMPELLED TO WHEEL OR WALK BEHIND PARKED CARS OTHER THAN THEIR OWN. PEDESTRIAN WAYS, WHICH ARE ACCESSIBLE TO PERSONS WITH DISABILITIES, SHALL BE PROVIDED FROM plainly visible from roadway. Suite numbers three (3) inches high, shall be plainly visible from outside the suite. Only materials stored on site will be food items and serving products. G.C. e BREA, CA 92821 shall provide 2A 108C minimum rated fire extinguisher within 75 feet travel distance from all areas. Travel distance is 30 feet in areas having flammable liquids. Fire sprinkler system 714 529-9523 OFFICE FAX z EACH SUCH PARKING SPACE TO RELATED FACILITIES, INCLUDING CURB CUTS OR RAMPS AS NEEDED. RAMPS SHALL NOT ENCROACH INTO ANY PARKING SPACE. - J p I U CEJD Vi H I per N.F.P.A. Standard 1999. Exit doors shall be operable from the inside without the use of a key or any special knowledge or effort, Self-releosing locking devices on exit doors"This _ 11298.2 LESS THAN FIVE SPACES. -' H = o door to remain unlocked during business hours" with minimum 1 inch letters shall be provided above exit door'EXIT" signs sholl be in block letters, a minimum of six (6) inches high with :.• WHEN LESS THAN FIVE PARKING SPACES ARE PROVIDED AT BUILDING AND FACILITIES SUBJECT TO THESE REGULATIONS, ONE SHALL BE 14 FEET (4267 MM) WIDE AND LINED TO PROVIDE A 9-FOOT (2743 MM) PARKING AREA a stroke of not less than 3/4 inch. luminance on face of sign shall be 50 lux"EXIT" signs shell be electrically illuminated and energized from separate circuits. One circuit shall be part of c /'"� { /� { o z AND A 5-FOOT (1624 MM) LOADING AND UNLOADING AREA. HOWEVER, THERE IS NO REQUIREMENT THAT THE SPACE BE RESERVED EXCLUSIVELY OR IDENTIFIED FOR USE BY PERSONS WTH DISABILITIES ONLY. emergency lighting systemStorage, dispensing, or use of any flammable or combustible liquids, flammable gases, and hazardous chemicals shall comply with Uniform Fire code SITE LOCATION ¢ > F11 w 0 NO0requirements. LICE FINAL INSPECTION m w z REQURED � o� o 1. K.EC. PLANS ARE PROVIDED FOR THE PURPOSE OF INDICATING MECHANICAL LOCATIONS AND EQUIPMENT REQUIREMENTS ONLY AND ARE NOT TO BE CONSTRUED BY THE GENERAL CONTRACTOR OR THE SUBCONTRACTORS AS TO RELIEVE THEM FROM THEIR RESPONSIBILITY OF COMPLYING WITH ALL APPLICABLE CODES, 2. IT SHALL BE THE RESPONSIBILITY OF THE OWNER AND/OR HiS ASSIGNED AGENT TO ENSURE THAT K.E.C. RECEIVES COPIES OF ALL ADDENDUM AND CHANGES TO BUILDING PLANS WHICH ARE MADE PRIOR TO AND DURING CONSTRUCTION. IN THE EVENT THAT THIS INFORMATION IS NOT DELIVERED TO K.E.C., OWNER WILL BE RESPONSIBLE FOR ALL COSTS INCURRED BY THE FAILURE TO GIVE F.S.E.C. THIS INFORMATION. 3. GENERAL CONTRACTOR SHALL PROVIDE PROPER BACKING FOR ALL WALL HUNG EQUIPMENT, SHELVING, ETC., AS INDICATED ON WALL BACKING DETAIL, 4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL GENERAL CLEANUP AND DISPOSAL OF ALL TRASH, CARTONS, CRATES, DEBRIS, ETC., AFTER FINAL INSTALLATION OF ALL FIXTURES. 5. SPRINKLER HEADS IN WALK-IN FREEZER AND COOLER ROOMS WiLL BE SUPPLIED BY AND ADEQUATELY PROTECTED AGAINST FREEZING UP BY FIRE SPRINKLER CONTRACTOR. 6, PLUMBERS AND ELECTRICIANS AND ALL OTHER TRADES INVOLVED MUST CONFORM TO APPLICABLE CODES. 7. HVAC CONTRACTOR TO ENSURE ALL EXHAUST FANS WILL BE CAPABLE OF DELIVERING CFM REQUIREMENT AS NOTED ON PLANS. K.EC, IS NOT RESPONSIBLE FOR ANY OBJECTIONAL ODORS OR SMOKE DELIVERED INTO THE SURROUNDING AREA. HVAC CONTRACTOR TO BALANCE EXHAUST, MAKE-UP AiR AND AIR CONDITIONING. 8. IF WALK-IN LOW TEMPERATURE AND NORMAL TEMPERATURE REFRIGERATION ROOMS ARE BUILT-IN TYPE, INSULATION AND PROPER VAPOR BARRIER, INTERIOR LIGHTS AND SWITCHES (INSIDE AND OUTSIDE), SPRINKLERS AND INTERIOR FINISH IS BY GENERAL CONTRACT. 9. IN EVENT RACEWAY IS INDICATED ON CURB PLAN, THE GENERAL CONTRACTOR WILL BACKFILL EXPOSED AND ACCESSIBLE OPENING OF RACEWAYS AND OTHER EXCESSIVE OPENINGS AFTER INSTALLATION OF FIXTURES TO PREVENT VERMIN INFESTATION. 10. SWINGING DOORS iN PASSAGEWAYS SHALL BE PROVIDED WITH WINDOWS MICH SHALL BE 8" X 24" OR OF A SUBSTANTIAL EQUIVALENT AREA TO MEET OSHA REQUIREMENTS. THE GLASS SHALL BE EITHER SHATTERPROOF OR WIRE GLASS AND THE BOTTOM OF THE WINDOWS SHOULD NOT BE MORE THAN 48" ABOVE THE FLOOR. 11. GENERAL CONTRACTOR TO CUT OR PROVIDE HOLES THROUGH CEILING, ROOFS AND WALLS FOR DUCTS, ETC., IN ACCORDANCE WITH LOCAL FIRE AND BUILDING CODES AND IN ACCORDANCE WITH DUCT SIZES SPECIFIED BY F.S.E,C. GENERAL CONTRACTOR ALSO TO PROVIDE ALL DUCT FIRE SEPARATIONS, ENCLOSURES, WRAPPINGS, SPRINKLER SYSTEM, ETC., AS MAY BE REQUIRED BY LOCAL BUILDING AND FIRE CODES. 12. PLUMBING AND/OR ELECTRICAL FINAL CONNECTIONS AND INTERNAL WIRING AND PLUMBING OF EQUIPMENT AND FIXTURES INDICATED ON THESE PLANS ARE NOT PART OF K.E.C. CONTRACT AND ARE TO BE DONE BY G.C. 13. ALL CANTILEVER BRACKETS FOR TABLES AND STOOL SEATS OR OTHER EQUIPMENT TO BE PROVIDED BY K.E.C. BUT INSTALLED BY GENERAL CONTRACTOR AND SHALL BE INSTALLED IN ACCORDANCE WITH SPECIFICATIONS AND DIMENSIONS PROVIDED BY F.S.E.C. GENERAL CONTRACTOR TO PROVIDE PROPER BACKING FOR SUPPORT BRACKETS. 14. MAKE-UP AIR: THE MAKE-UP AIR SYSTEM SHALL HAVE A SUFFICIENT CAPACITY TO MAKE UP 100% OF THE AIR BEING EXHAUSTED AND SHALL BE BALANCED TO MAKE-UP UP TO 90% OF THAT AIR, MAKE-UP AIR GRILLS SHALL BE EQUIPPED WITH KEY OPERATED OPPOSED BLADE VOLUME CONTROLS, MAKE-UP AIR GRILLS SHALL BE EQUIPPED FOR MAXIMUM OUTLET VELOCITY OF 400 FPM. MAKE-UP AIR SHALL BE DELIVERED IN THE PROXIMITY OF THE EXHAUST SYSTEM IN A MANNER NOT TO CREATE UNIQUE AIR TURBULENCE IN THE WORKING AREA. MAKE-UP AIR SYSTEM SHALL BE CAPABLE OF DELIVERING AiR AT 70 DEGREES, 15. UNLESS OTHER PROVISIONS ARE MADE AND/OR INDICATED ON PLAN, GENERAL AND/OR HVAC CONTRACTOR TO PROVIDE TEMPERED MAKE-UP AiR FOR EXHAUST HOODS IN ACCORDANCE WITH REQUIREMENTS INDICATED (NOTE #16) 16. G.C. TO ENSURE WALL LAMINATE I$ FIRST ADHEARED TO A SUBSTRAITE PRIOR TO BEING INSTALLED ON THE WALL. G.C. TO ENSURE LAMINATE BRAND INSTALLATION INSTRUCTIONS ARE FOLLOWED AND THESE INSTRUCTIONS WILL SUPERCEDE ANY NOTATIONS ON THESE PLANS. 17, ALL ENCLOSED PORTIONS OF BUILDINGS CUSTOMARILY OCCUPIED BY HUMAN BEINGS SHALL BE PROVIDED WITH A MECHANICALLY OPERATED VENTILATION SYSTEM. SUCH MECHANICALLY OPERATED VENT SYSTEM SHALL BE CAPABLE OF SUPPLYING A MIN. OF 15 CU, FT PER MIN OF OUTSIDE AIR PER OCCUPANT DURING SUCH TiME AS THE BUILDING IS OCCUPIED. IF THE VELOCITY OF AIR AT A REGISTER EXCEEDS 10 FT PER SECOND, THE REGISTER SAALL BE PLACED MORE THAN 8 FTEET ABOVE THE FLOOR DIRECTLY BENEATH. CBC SECTION 1202.2.1 HEALTH DEPARTMENT NOTES 1. SUBMIT SAMPLES OF WASHABLE CEILING TILE FOR APPROVAL PRiOR TO INSTALLATION. (SEE CEILING PLAN FOR SPEC.) 2. ALL FLOOR SINKS ARE TO BE HALF EXPOSED OR BE IN LINE WITH FACE OF ELEVATED FREESTANDING EQUIPMENT AND WITHIN 15 FEET CONDENSATE PRODUCING EQUIPMENT. 3. ALL EXTERIOR AND RESTROOM DOORS ARE TO BE SELF CLOSING. 4. ALL EQUIPMENT MUST BE SUPPORTED BY A MIN, 6" HIGH LEGS, COMMERCIAL CASTERS OR BE COMPETELY SEALED IN POSIION ON A 6" HIGH CONTiNOUS COVED BASE, 5. NSF STANDARDS ARE USED AS THE GUIDE FOR EQUIPMENT EVALUATION. 6. ALL PLUMBING, ELECTRICAL & GAS LINES SHALL BE: CONCEALED WITHIN BUILDING STRUCTURE TO AS GREAT AN EXTENT AS POSSIBLE. 7. HORIZONTAL RUNS OF DRAIN LINES SHALL BE AT LEAST Y+" FROM THE WALL & 6" OFF THE FLOOR AND SHALL TERMINATE AT LEAST AT LEAST 1" ABOVE THE OVERFLOW RIM OF THE FLOOR SINK. 8. ALL LAYS & HAND SINKS WILL HAVE A COMBINATION OR PREMIXING FAUCET CAPABLE OF SUPPLYING WARM WATER FOR A MIN. OF 10 SECONDS. 9. JANITORIAL SINK IS TO BE PROVIDED W/ AN APPROVED BACKFLOW DEVICE. TO. ALL SHELVING OVER WET AREAS (SINKS, ETC) TO BE STAINLESS STL IT. OUTSIDE TRASH AREA HAS CONCRETE SLAB AND SMOOTH FINISH BLOCK WALLS THAT ARE SEALED AND WASHABLE. 12. EXHAUST FAN IN TOILET ROOM IS TO PROVIDE 12 AIR CHANGES PER HOUR AND IS ACTIVATED W/ LIGHT SWITCH. 13. NOT USED 14. HOT WATER HEATER IS 40 GAL., 9 KW HIGH RECOVERY. 15. ALL REQUIRED SNEEZE GUARDS WILL COMPLY W/EFiP-885 REQUIREMENTS. 16. FLOORING TO SELF-COVING 6" HIGH W% 3/8" MIN, RADIUS. 17. SUBMIT CONCRETE SEALANT SPECIFICATIONS TO HEALTH DEPT. FOR APPROVAL. LIGHT NONSLIP FINISH IS APPROVED ONLY IN TRAFFIC AREAS, SURFACES UNDER EQUIPMENT TO BE SMOOTH. 18. SHATTER SHIELDS TO BE PROVIDED ALL LIGHTS ABOVE FOOD PREPARATION, WORK & STORAGE AREAS. 19. A MINIMUM OF 20 FOOT CANDLES OF LIGHT 0 30" ABOVE FIN. FLR, IN FOOD PREP., PACKAGING , PROCESSING AND UTENSIL CLEANING AREAS. 20. PROVIDE A MIN. OF 10 FOOT CANDLES OF LIGHT 0 30" ABOVE FIN, FUR. IN ALL STORAGE & TOILET ROOMS. 21. ALL AREAS OF THE FACILITY ARE TO PROVIDED W/ 20 FOOT CANDLES OF LIGHT @ 30" ABOVE FIN. FLR. DURING CLEANUP ACTIVITIES. 22, ALL 2 & 3 COMPARMENT SINKS ARE TO HAVE A MIN, COMPARTMENT SIZE OF 18"x 18"x 12" DEEP OR 16"x 20"x 12" DEEP, W/ DRAIN BOARDS 18" WIDE 0 EA. END & A MIN. OF 8" INTREGAL BACK SPLASH @ ALL WALLS. 23. ALL SERVICE IS IN DISPOSABLE CONTAINERS & UTENSILS. 24. NO ALCOHOLIC BEVERAGES ARE SERVED. 25. TOWEL AND SOAP DISPENERS ARE TO PROVIDED 0 HAND SINK. 26. ALL NEW SINKS ARE TO PROVIDE HOT & COLD WA`ZR THROUGH MIXING FAUCETS AT A CONSTANT MIN. TEMP. OF 120 PER CODE. 27. ONLY SINGLE SERVICE UTENSILS TO BE USED. 28. MAXIMUM NUMBER OF EMPLOYEES ON ANY ONE SHIFT = 3. 29, EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE: WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, CBC SECTION 1003.318 HANDICAPPED RESTROOM NOTES GRAB BARS WATER CLOSETS 1. Grab bar to be 33" above and parallel to the floor. Z Side grab bars to be 42" long and project 24' in front of the water closet stool. Grab bar at back to be 36" long. 1. The height of the water closet (top of seat) shall be between 11 and 19 inches. 3, Diameter of grab bars to be 1-Y" to 1-f ". 2. Flush controls to be operable by an oscillating handles with a maximum force of 3 pounds. 4. Provide 1-f "clearance between grab bars and wall RI VIALS 5. Grab bars (including connectors,fasteners, support backing, etc.) shall be designed to support a 250 # load. 6. Grab bars shall not rotate within their fittings. 1. Urinals shall have rims projecting a minimum of 14' from the wall and the rims 7. Grob bars are to be located on each side or on one side and back of water closet, shall be within 17" of the floor. B. Grab bars shall comply with CBC section 1115b.8 and have a 2501b point load. LAVATORIES TOILET ROOM ACCESSORIES 1. Provide a clear floor space 30" by 48" in front of lavatory to permit a forward approach, 1. Bottom edge of mirrors to be no higher than 40" from the floor. 2. Minimum 29" clear from floor to bottom of apron with knee. 2. Toilet tissue dispensers to be mounted within 12" from the front edge of the toilet seat, 3, Provide a clear space beneath the lavatory 27" high by 30" wide by 8" deep at the top and 3. Operating parts of dispensing and disposal fixtures (towel, sanitary napkins, waste, coin slots, etc.) are to be with -in 40" from floor 9" high by 30" wide by 17" deep at the bottom, 4. Hot water and drain pipes under lavatory to be insulated or covered and be free of sharp or abrasive surfaces. 5. Faucet controls and operating mechonisims (operable with one hand) shall be of the type not requring tight grasping, pinching or twisting of the wrist, or an operating force exceeding 5 pounds. 6. Self closing valves permitted if faucet remains open for at least 10 seconds. SiNGLE ACCOMMODATION TOILET FACILITIES 1. There shall be sufficient space in the toilet room for a wheel chair measuring 30" wide by 48" long to enter the room and permit the door to close. 2. The water closet shall be located in a space which provides a 28" wide clear space from a fixture or a 32" wide clear space from a wall at one side and 48" of clear space in front of the water Closet. 3, Doors to the toilet facility shall be identified by %" thich geometric symbols of contrasting color and centered on the door at a ht. of 60"; 12" equilateral triangle for men and 12" dia. circle for women. S34` veTEMPEHEOG GLASS EEZEGUAR 54" 3a• SERVICE COUNTER DETAIL NO SCALE _ 54" MAX. HT, OF PUSHBUTTON I ONTROLS 34" SAFE 1 AX. _t_�_ J COUNTER @ POINT OF SALE DRINK DISP. & CONDIMENT AREA NO SCALE NO SCALE r7 NO. ROOM OF AREA FLOOR FLOOR BASE OR COVE WALLS CEILING CUSTOMER CROSSVILLE CERAMIC TILE SURFACE BULLNOSE BASE SUBWAY MURAL VINYL WALL 2 x 2 ACOUSTIC 0 AREA POMPEII VS53, VS56, VS54 3% 12" COVERING OVER TUSCAN LAY IN CEILING TILES STUCCO ViNYL WALL COVERING SELF -SERVE CROSSVILLE CERAMIC TILE 6% 12" SUBWAY MURAL VINYL WALL 2 x 2 WASHABLE CEILING FAN 3`0" X 7'0" � AREA POMPEII VS53, VS56, VS54 SANITARY COVE BASE COVERING OVER TUSCAN~'- STUCCO VINYL WALL COVERING LAY IN CEILING TILES (B) FRONT DOOR TO BE LABELED MTK THIS DOOR TO REMAIN UNLOCKED PUBLIC RESTROOM MARLlTE FRP TO 8 FT. AFF SEMI -GLOSS PAINT DUNN- �i (TYPICAL} CROSSVILLE CERAMIC TILE 6"x 12" DURING BUSINESS HOURS° C/ � \ POMPEII VS53, VS56, VS54 SANITARY COVE BASE EDWARDS COTTAGE WHITE ( / 8 6" EPDXY COVE TILE. DAL TILE X735 ALMOND KITCHEN AREA EPDXY W/ 3/8" RADUIS COVE W/ 2x2 DECO PATTERN WASHABLE CEILING TILE 0 7 FT. AFF 6" EPDXY COVE STORAGE AREA EPDXY W/ 3/8" RADUIS COVE FRP WASHABLE CEILING TILE JANITORIAL 6" EPDXY COVE AREA EPDXY W/ 3/8" RADUIS COVE FRP WASHABLE CEILING TILE l 1 EMPLOYEE 6" EPDXY COVE / 11 8 LOCKER AREA EPDXY W/ 3/8" RADUIS COVE FRP WASHABLE CEILING TiLE OFFICE N/A N/A N/A N/A 1 1 1 C 10 WALK-IN EPDXY 6" EPDXY COVE BASE GALVANIZED METAL GALVANIZED METAL COOLER FLASHED TO T-BAR ABOVE 11 WALK-IN GALVANIZED FLOOR GALVANIZED METAL SjS FLOOR GALVANIZED METAL FREEZER W/ 3/8" RADUIS COVE FLASHED TO T-BAR ABOVE EQUIPMENT SCHEDULE ITEM DESCRIPTION MFG. MODEL # HW CW WASTE VOLT AMPS REMARKS 8 TRASH RECEPTACLE PLYMOLD 9 SODA MACHINE PEPSI/NAT'L. CARBONIC - 1/2" 3/4" REDUCED PRESSURE BACKFLOW DEVICE 10 BEVERAGE DESTINATION CENTER 11 RED NEON "OPEN" SIGN 120/1 20, 0 AMPS 14 CHIP RACK - 15 DISPLAY REFRIGERATOR 120/1 4. 7MMPS 18 GUIDANCE SYSTEM - - 19 FRONT COUNTER DUKE MFG. CO. 120/1 7.9%4.6 AMPS 22 DISPLAY REFRIGERATOR 120/1 20. 0 AMPS 23 SAFE BY OWNER - 24 SUBSHOP 2000 P.O.S. BY OWNER 120/1 2. 0 AMPS 25 MICROWAVE (QTY: 2) AMANA RFS105W2 120/1 8. 3 AMPS 27 BREAD OVEN NUVU OP2-FM 1/2" 208/3 21, 0 AMPS 28 ENCLOSED BREAD CABINET LOCKWOOD - 29 MENUBOARD AMERICAN SIGN - 31 BACK COUNTER W/ HAND SINK DUKE MFG. CO. 1/2" i/2" 1-1/2" 32 BACK COUNTER DUKE MFG. CO. 101-1-1 33 REFREGERTED BACK COUNTER DUKE MFG. CO. 120/1 3. 8 AMPS 34 RAPID COOK OVEN 220/1 30. 0 AMPS 35 ICE MACHINE MANITOWAC SD-0592N 1/2" 3/4" 120/1 14. 7 AMPS 2. 3 AMPS ON ROOF 36 SiNK L&B SHT. METAL - 1/2" 1/2" 1-1/2" 37 MOP SiNK FLORESTONE MSR2424 1/2" 1/2" 3" CHICAGO #895 FAUCAET Wit VACUUM BREAKER 38 HOT WATER TANK (40 GAL,) RHEEM RUUD ELD40 3/4" 3/4" 3/4" 208/1 40. 0 AMPS 39 S.S. WORKTABLE DUKE MFG. CO. 3072 40 S.S. WALL SHELF DUKE MFG. GO, 43 CLEANING PRODUCTS RACK 45 SLICER NEMCO 46 RETARDER CABINET 47 REFRIGERATOR (UL / NSF) NORLAKE KL7486-CX-M 3/4" 120/208/1 15. 0 AMPS FLASH TO CEILING & WALLS 48 FREEZER (UL / NSF) NORLAKE KL7766-CX-M 3/4" 120/208/1 15, 0 AMPS FLASH TO CEILING & WALLS 49 STORAGE UNITS 50 SODA STORAGE PEPSI/NAT'L. CARBONIC - CHAIN TANKS TO WALL 51 STEREO SYSTEM 52 AIR CURTAIN MARS AIR CURTAIN 20/208/1 5. 0 AMPS MICRO SWITCH TO OPERATE WHEN DOOR OPEN DOOR SCHEDULE ITEM DESCRIPTION (A) 3'-0" x 6'-8" SOLID CORE DOOR ON TIMELY METAL FRAMES LEVER HARDWARE (8) S-0" x 7'-0" STORE FRONT GLASS DOOR. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGTH ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE U11LIZED TO MEET THE ABOVE STANDARD. CBC SECTION 11338.2.5 ALL DOORS SHALL BE SMOOTH AND HAVE A UNINTERRUPTED SURFACE 10 INCHES FROM BOTTOM. SHEET INDEX SHEET NO. DESCRIPTION KOA COVER SHEET K1.1 EQUIPMENT PLAN AND NOTES K2.1 PLUMBING / ELECTRICAL ROUGH -IN PLANS K3.1 REFLECTED CEILING PLAN/ CONSTRUCTION PLAN 11 mill � I - Il 30'X48' CLEAR SPACE REQUIRED o GENERAL NOTES- - CEILING HEIGHT IS 8'7" - ELECTRICAL OUTLET HEIGHTS MEASURED TO BOTTOM OF BOX. - ONE ELECTRICAL JUNCTION BOX TO BE LOCATED IN CEILING ABOVE EACH WINDOW. - STORE DESIGNED WITH CONTOUR SEATING. SHOWN ON PLAN AS SINGLES NOT GROUPS. - CUNO MODEL SW3-EL-1H WATER FILTRATION SYSTEM IS REQUIRED IN ALL NEW STORES THAT DISPENSE BEVERAGES (IN CANADA THE ECOLAB FRESH H2O REMAINS OPTIONAL). THE RECOMMENDED PLACEMENT FOR INSTALLATION IS REMOTE MOUNTING ONTO THE BACKROOM BEVERAGE SYRUP RACK OR MOUNTING ONTO BACKROOM WALL. OPTIONAL INSTALLATION MOUNTING INSIDE THE FRONT BEVERAGE COUNTER WHERE SPACE LIMITATIONS OCCUR, iN AREAS WHERE CHLORAMINE IS IN USE BY THE LOCAL MUNICIPALITY THE CUNO MODEL CFSCRC CANISTER IS REQUIRED TO BE INSTALLED IN ADDITION TO THE STANDARD SW3-EL-1H SYSTEM. REQUIRED: 1/2" INCOMING WATER LINE FEED WITH 1/2" BALL VALVE SHUTOFF AND 1/2" FPT CONNECTION. MINIMUM 110 VOLT, 20 AMP ELECTRICAL SERVICE TO SUPPORT THE CARBONATOR AND WATER BOOSTER (MUST BE DEDICATED CIRCUIT). - PROMOTIONAL FLOOR STAND (MFR, TRANS WORLD) REQUIRED IN CUSTOMER AREA AT POINT OF ORDER (PREFERRED PLACEMENT). 14 1/2" X TO- BASE, 54" OVERALL HEIGHT. - EXIT LIGHTS INSTALLED BY G.C. PER LOCAL CODE. - EMERGENCY LIGHTS INSTALLED BY G.C. PER LOCAL CODE. - EXTINGUISHERS, SMOKE AND FiRE DETECTION SYSTEMS INSTALLED BY G.G. PER LOCAL CODE. A S BY ESS HERWISE ALL DLMEN NS TO E VERIFY Y G.C. ITE. - DECOR SPECIFICATIONS ARE TO BE SUBWAY'S "TUSCANY' S=HEM QUANTITIES OF HAZARDOUS MATERIALS CANNOT EXCEED AMOUNTS PERMITTED iN CODE TABLES 3D 3E r ALL DISPENSERS + 40" MAX TO HIGHEST OPERABLE PART 36" GRAB BAR 42" GRAB BAR MAX. i� 1 ;(23)W 1 4'_5" 4i f MIRROR GLASS I I I I 1 L_ I I � L__�, PHONE. JACK ELECT PANEL 40 45 3'0" X 6`8" LH Co (A) x�3 (A) _ O ,t III�I11i 4'-1" L �. 2'-0- 5. 5„ PRE -FA FACTOR�%ED 48 PRE-FAB FACTORY WIRED WALKI 10 47 1 r4 -- W T DOORSSHE B (' 30X $ FROM HT THE 1 �J2 13 USE OF A KEY OR ANY SPECIAL 1 1 KNOWLEDGE 1 1 �o LOCKERS LOCKER AREA COMPLIANT WITH CODE SE.1125b HARDWARE HEIGHTS O •1 AIL 1-1/4" TO 1-1/2" NOMINAL DIAMETER 16 1 N W ry W .� Do <O Q 0 Li Do :Dry t7� Q Z W r W General Notes This plan and the designs herein are the sale property of JM and may not be reproduced, changed or used by anyone, in port or whole, without the written permission of a JM company officer. Any desired devotions to this Pico must be approved in writing byy JM before such work is done. it is the nsibil` of anyone using this resfa dY g pion to read and become familiar With all information shown hereon including onyy list of notes. Measurements on this plan are from avadabie Information. At will not assume any responsibility far the acc uacy of such information. Fabr atone, contmctas, etc. using this plan are to confirm oil information on this plan with the job site. All information on this plan for the general contractor or the general can - tractor's subcontractors to perform (plumbing, electrical, curbs, wags, budding openings, etc.) are for the sole purpose of equipment requirements; reference is mode to the owner or architectual plans for engineering or fisting of Hems not supplied by JM, JM will not assume any respon- sbiiity, for engineering thereof. AG buiM'an� work thereof shall be by the general contractor including all roughing -in and final connections and all runs to equipmend and in- cluding all fittings or any other parts materials or labor for such work. H any such work is in JM oo*A it will spedficWly be indicated on this flan; if it is not specifically irndicated on ffus plan, it is not a part of JM contmet and shall be provided by others. JM wall ossume no responsibility for work done by the general contractor or a subcontractor of the general contractor or any changes made necessary by locos codes (inducting: Building, Heahh Depart. ordinances, Fire Depart, etc.) or changes by the owner, architect or any other person outside of JM with authority to the design. This plan becomes void upon such changes amd work cannot be completed unbi the appropriate eorrsctions are mode by JM. Using this plan is admit- tance that all information on this pion has been examined and compared with other plans (example: architectural plane) and any inconsistencies, errors, ambiguities or omis- sions have been reported to IM for written corrections before completing bids or camaamcsng any work hereunder. No additional allowance will be made for such work unless H is agreed before acceptance of bids. plumbing or electrical parts not supplied with the equipment as a standard Hem shall be provided by the plumber or electricion unless specifically indicated on this plan. 03-25-05 SUBMITTAL DOCUMENT k4 Date RevisiaFt/issue 11 < QU < U Z <___ 0< I� a 0 a z U P rL Q n W w jd i z .�".. LJ to W ai z 0 cis x z 0 z V) ' ll m W N a M z W z L:i z 0 o ran !1 EQUIPMENT PLUMBING NOTES: 1. K.E.C. PLANS ARE FOR THE SOLE PURPOSE OF INDICATING THE LOCATION OF OUTLETS AND EQUIPMENT REQUIREMENTS. PLUMBING MUST COMPLY WITH ALL APPLICABLE CODES. 2. ALL PLUMBING OUTLETS AND CONNECTIONS SHOWN ON THIS PLAN ARE FOR FIXTURES AND EQUIPMENT SHOWN ON K.E.C. FLOOR PLAN, ONLY. FOR ADDITIONAL FLOOR DRAINS AND BUILDING PLUMBING REQUIREMENTS, SEE ARCHITECT, GENERAL CONTRACTOR OR OWNER. 3. ALL HORIZONTAL DIMENSIONS SHOWN ARE TAKEN FROM FACE OF FINISHED WALL TO CENTERLINE OF OUTLET OR FROM CENTERLINE OF OUTLET TO CENTERLINE OF OUTLET, UNLESS OTHERWISE NOTED ON PLAN OR DETAI� MINIMUM OF LS. TED upp 4. ALL SYMBOLS ALLOM FLOOR WNOTAT NSINISHED CUROR T, T OUENTEOR NE OFP OF NHT IJND�&J& HEIGHT IS GIVEN OUT OUTLET. FLOOR, OR FINISHED CURB, AS THE CASE MAY BE, A MAXIMUM OF 4" SO AS NOT TO INTERFERE WITH THE INSTALLATION OF FIXTURES. CONTRACTOR TO VERIFY ALL DIMENSIONS AT JOBSITE, 5. ALL FLOOR SINKS HALF IN OR HALF OUT OF CURB TO BE FLUSH WITH FINISHED FLOOR. ALL FULLY OR PARTIALLY EXPOSED FLOOR SINKS TO BE PROVIDED WITH COVERS. FLOOR SINKS HAVE BEEN LOCATED WITH THE ASSUMPTION THAT THEY WILL BE SET FLUSH WITH FINISHED FLOOR (UNLESS OTHERWISE NOTED). IN THE EVENT LOCAL CODES REQUIRE FLOOR SINKS TO BE ABOVE OR BELOW FINISHED FLOOR LEVEL, GENERAL CONTRACTOR SHALL COMPLY WITH LOCAL CODES, AND NOTIFY K.E.C. IMMEDIATLY. 6. GENERAL CONTRACTOR TO CONNECT ALL WATER LINES, GAS LINES FIRE SYSTEM SOLENOID , WASTE LINES, ETC, FOR SINKS, ISHWASHERS, ETC. At�D RUN DRAIN LINES FROM ALL REFRIGERATED UNITS, ICE SINKS, ETC. (SEE NOTE �7} TO FLOOR SINKS AND DIRECT OR INDIRECT WASTE LINES TO BE NOT SMALLER THAN NIPPLE OF FIXTURE ITSELF. 7, GENERAL CONTRACTOR TO PROVIDE INSULATED DRAIN LINES FROM ALL ICE STORAGE SINKS/PANS TO PREVENT DRAIN FROM SWEATING WITHIN FIXTURE. & GENERAL CONTRACTOR TO PROVIDE THE FOLLOWING ITEMS: o. GATE VALVES ON ALL WATER AND GAS LINES, AND WADE SHOCK STOPS (MODEL #W5 OR EQUAL) ON GLASS FILLERS AND DISHWASHERS. b. ALL FAUCETS FOR SINKS UNLESS OTHERWISE NOTED (TO BE SUPPLIED AS SPECIFIED). c. ALL VALVES, TRIMS AND PRESSURE REGULATORS NECESSARY TO CONNECT ALL VIES. d. TEMPERATURE AND PRESSURE SAFETY RELEASE VALVES FOR HOT WATER BOOSTER AND STEAM SYSTEMS, IF USED. e. NECESSARY WATER LINES, DRAIN LINES {AS REQUIRED} ON ROOF FOR MAKE-UP AIR SYSTEM. FOR `LOCATION AND EXHAUST REQUIREMENTS, SEE ARCHITECT AND/OR HVAC CONTRACTOR. L BACKFLOW PREVENTION DEVICES, AS REQUIRED BY CODE. g, DILECTIC COUPLERS, WHEN CONNECTING GALVANIZED IRON PIPE TO COPPER. 9. K.E.C. RECOMMENDS A RECIRCULATING HOT WATER SYSTEM BE PROVIDED FOR DISHWASHING MACHINE. DISHWASHING MACHINE REQUIRES GPH OF DEGREE HOT WATER 0 FLOW PRESSURE. VERIFY WITH ARCHITECT, GENERAL CONTRACTOR OR OWNER AND MAKE PROVISIONS FOR ADEQUATE WATER SUPPLY ACCORDINGLY. 10. GENERAL CONTRACTOR TO PROVIDE HARD TUBING DRAIN LINE 4SEE NOTE 6) 1'-6' DOWN FROM FINISHED CEILING IN WALK-IN (AT BLOWER OILS IN WALK-IN REFRIGERATOR AND WALK-IN FREEZERS}, 45 DEGREE ELBOW FROM COIL AT A MINIMUM FALL OF 2' PITCH PER V-O" TO FLOOR SINK. DRAIN LINES MUST BE OUTSIDE OF INSULATION TO PREVENT FREEZING IN LOW TEMPERATURE BOXES AND 'P" TRAPS MUST BE FORMED IN FREEZER COIL DRAIN LINE OUTSIDE OF FIXTURE AT OR NEAR FLOOR SINK. STUB OUT AT 18' AT EACH END. 11. SPARE 12. WASTE NE ON SOME DISHWASHERS ARE AS LOW AS 7" FROM CENTERLINE OF DRAIN ABOVE FINISHED FLOOR LEVEL. GENERAL CONTRACTOR MUST YVL�RIFY HEIGHT OF DISHWASHER DRAIN AND MAKE ADEQUATE PROVISIONS FOR "P" TRAP (IF NECESSARY 'P" TRAP TO BE SET IN FLOOR). 13. WATER PROVIDED TO COFFEE URNS OR COFFEE MAKERS MUST NOT FEED OFF WATER SOFTENERS, UNLESS OTHERWISE DIRECTED. 14. GENERAL CONTRACTOR TO VERIFY METHOD AND LOCATION OF REFRIGERATED DISPLAY CASES (WALL MOUNTED) DRAIN IN WALL WITH F.S.E.C. BEFORE WALLS ARE PLASTERED AND EQUIPMENT IS INSTALLED. 15, ALL WORK SHOWN ON FIXTURE PLUMBING PLAN AND OUTLINED IN ABOVE NOTES TO BE PERFORMED BY GENERAL CONTRACTOR UNDER BUILDING CONTRACT. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO SEE THAT HIS PHASE OF WORK MEETS AND IS INSTALLED IN ACCORDANCE WITH STANDARDS REQUIRED BY ALL GENERAL STATE AND FEDERAL LAWS_(INCLUDING HEALTH CODES} AND ANY AND ALL CODES PECULIAR TO THE MUNICIPALITY OF AREA WHERE JOB IS BEING INSTALLED. IMPORTANT NOTE: SEE REFRIGERATION PLAN FOR ADDITIONAL INFORMATION NOTES: 1. GENERAL CONTRACTOR TO VERIFY SIZES WALK-IN COOLERS / FREEZER BEFORE LOCATING FLOOR SINK(S) FOR BLOWER COILS(S) DRAINAGE. 2, G.C. TO VERIFY W/ LOCAL CODES AND REQUIREMENTS (INDIRECT TO FLOOR SINKS, FUNNEL DRAINS OR DIRECT) TO DISHWASHERS, POT SINKS, PREP. SINKS ETC. 3. G.C. OR OWNER RESPONSIBLE TO ENSURE EQUIPMENT WILL FIT TROUGH EXISTING DOOR FRAMES PLUMBING ROUGH -IN SYMBOLS i COLD WATER HOT WATER (SEE SCHEDULE FOR TEMPERATURE REQUIRED) 03 DIRECT WASTE (WALL) Q DIRECT WASTE (FLOOR) ® FLOORSiNK (12"02'xe DEEP WITH 2" WASTE AND 1/2, 3/4 OR FULL GRATE AS INDICATED, UNLESS OTHERWISE SPECIFIED.) " DIRECT CONNECTION FROM ROUGH -IN TO EQUIPMENT POINT OF CONNECTION INDIRECT WASTE FROM EQUIPMENT TO FLOORSINK 35 36 f- i w-. F' Lr �J 37 38 I N 47 48 DCO DCO DCO EQUIPMENT ELECTRICAL NOTES: 1. K.E.C, PLANS ARE PROVIDED FOR THE SOLE PURPOSE OF INDICATING THE LOCATION OF OUTLETS, TYPE OF CONNECTION FOR EQUIPMENT AND ELECTRICAL LOAD. SUBCONTRACTORS MUST COMPLY WITH ALL CODES RELATED TO THE INSTALLATION, WIRING AND HOOK-UP OF EQUIPMENT, 2. GENERAL CONTRACTOR TO PROVIDE MAGNETIC STARTERS, DISCONNECTS AND THERMO- OVERLOAD PROTECTION ON ALL MOTORS AND/OR EQUIPMENT WHERE REQUIRED, 3. GENERAL CONTRACTOR TO CONNECT ALL ELECTRICAL EQUIPMENT AND FIXTURES AND DO ANY INTERNAL WIRING IN FIXTURES. 4. GENERAL CONTRACTOR TO SIZE ALL JUNCTION BOXES. GENERAL CONTRACTOR TO PROVIDE ALL JUNCTION BOXES, REFRIGERATION PULL BOXES AND ELECTRICAL CONVENIENCE OUTLETS IN WALLS. K.E.C. TO LOCATE ALL CONVENIENCE OUTLETS AND SWITCHES WHERE PART OF FIXTURE, BUT INTERNAL WIRING FOR SUCH BOXES TO BE INSTALLED AND SUPPLIED BY GENERAL CONTRACTOR. WHEREVER ACCESS IS NOT AVAILABLE FOR THE GENERAL CONTRACTOR TO RUN HIS LINES FROM JUNCTION BOXES TO END USAGE IN FIXTURE, THE F.S.E.C. IS TO INSTALL SUITABLE CONDUIT FOR THE RUNNING OF SUCH LINES. ALL CONVENIENCE OUTLETS IN WALL TO BE FLUSH WITH FINISHED WALL GENERAL CONTRACTOR TO PROVIDE AND FIELD MOUNT ALL JUNCTION BOXES LOCATED IN ACCESS AREAS OF FIXTURES. 5. K.E.C, WILL CUT ACCESS HOLES TO CONVENIENCE OUTLETS IN BACKSPLASHES, ETC. BUT GENERAL CONTRACTOR TO PROVIDE EXTENSION SHIELDS, IF REQUIRED. 6. GENERAL CONTRACTOR TO PROVIDE AND INSTALL REFRIGERATION CONDUIT LINES FROM FROM COMPRESSOR AREA TO PULL BOXES OR "STUB -UPS" AS INDICATED ON REFRIGERATION PLAN; CONDUIT TO BE ROUND TRANSITS (OR EQUAL) DIAMETER AS INDICATED, WITH MINIMUM BENDING RADIUS OF 24" AND NO FACTORY CS PERMITTED. 7. ELECTRICAL CONTRACTOR TO CONNECT ALL COMPRESSORS AND BLOWER COILS COMPLETE WITH DISCONNECT SWATCHES AND MAGNETIC STARTERS, AS REQUIRED. 8. GENERAL CONTRACTOR TO PROVIDE POWER ON ROOF AND CONNECT EXHAUST FAN, MAKE-UP AIR FANS, HEATERS AND EVAPORATIVE COOLERS AND LOCATE SWITCHES WITH RED PILOT LIGHTS AS SHOWN ON F.S.E.C. ELECTRICAL PLAN SHEET K-4 OR AS DIRECTED BY HVAC CONTRACTOR. GENERAL CONTRACTOR SHALL CONNECT VAPOR -PROOF LIGHTS AS SHOWN ON F.S.E.C. ELECTRICAL PLAN K-4. DISCONNECT SWATCHES TO BE MOUNTED CONVENIENT TO EQUIPMENT ON ROOF. 9. GENERAL CONTRACTOR TO PROVIDE HOOK-UPS AND WIRING TO VAPOR -PROOF LIGHTS WALK-IN COOLER/FREEZER, COMPLETE WITH SWITCH WIRING LOCATED INSIDE AND OUTSIDE. SWITCHES TO HAVE RED BULLS EYE SIGNAL, BY F.&E.C., OR AS NOTED ON THIS SHEET, 10. GENERAL CONTRACTOR TO PROVIDE STAINLESS STEEL COVER PLATES FOR ANY FULLY OR PARTIALLY EXPOSED PULL BOXES AND/OR ELECTRICAL ACCESS BOXES AND TO PROVIDE STAINLESS STEEL COVER PLATES FOR ALL CONVENIENCE OUTLETS. 11, THE SYMBOLS ON THE ELECTRICAL PLAN ARE TO INDICATE LOCATION AND TYPE OF CONNECTION ONLY. GENERAL CONTRACTOR TO PROVIDE CIRCUITS AND CONDUIT RUNS, AS REQUIRED, 12. GENERAL CONTRACTOR TO PROVIDE CAPS AND CORDS FOR ALL ITEMS WHERE THEY ARE NOT STANDARD WITH MANUFACTURER AND SHORTEN ANY CORDS AND WIRING AS REQUIRED OR REQUESTED, I.E. FRYERS,, TOASTERS, LIGHT FIXTURES, ETC. 13. SPARE 14. SPARE 15, GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL LOCKOUT DEVICES ON ALL BREAKERS FOR CLOCKS, REFRIGERATION, CONTROL WIRING, EXHAUST SYSTEM CONTROLS AND FIRE EXTINGUISHER SYSTEMS. 16. GENERAL CONTRACTOR TO VERIFY LOCATION OF GAS SOLENOID VALVES WITH PLUMBER. GENERAL CONTRACTOR TO SUPPLY POWER AT VERIFIED LOCATION, 17, ALL CONVENIENCE OUTLETS TO BE SET HORIZONTALLY. ALL 115 VOLT OUTLETS NOT DESIGNATED WITH SPECIFIC LOADS TO BE RATED AT 20 AMPS. ALL 208/230 VOLT OUTLETS NOT DESIGNATED WITH SPECIFIC LOADS TO BE RATED AT 40 AMPS. 18. ALL ELECTRICAL OUTLETS AND CONNECTIONS SHOWN ON THIS PLAN ARE FOR FIXTURES AND EQUIPMENT SHOWN ON F.S.E.C. EQUIPMENT PLAN ONLY. SEE ARCHITECTS PLAN FOR FURTHER BUILDING ELECTRICAL REQUIREMENTS, 19. ALL HORIZONTAL DIMENSIONS ARE GIVEN FROM FINISHED WALL TO CENTER LINE OF OUTLET OR FROM CENTER LINE OF OUTLET TO CENTER LINE OF OUTLET, UNLESS OTHERWISE NOTED. CENTER LINE OF OUTLET, UNLESS OTHERWISE NOTED. ALL OUTLETS ALL OUTLETS N01ED up+12" OF up+24", ETC. TO STUB OUT OF WALL AT HEIGHT GIVEN. HEIGHT OF OUTLET IS GIVEN FROM FINISHED FLOOR (NOT TOP OF FINISHED CURB) TO CENTER LINE OF OUTLET. OUTLETS NOTED 'STUB -UP' OR 'STUB -OUT" OF FINISHED FLOOR AT LOCATION SHOWN, AND TO STUB UP MAXIMUM 4" ABOVE FINISHED FLOOR OR CURB. 20. ALL ELECTRICAL POWER NOT OTHERWISE NOTED TO BE SINGLE PHASE. 21. GENERAL CONTRACTOR TO PROVIDE POWER AT COMPRESSOR AREAS FOR COMPRESSORS (FOR EXACT LOCATION, CHECK WITH ARCHITECT) AS LISTED ON SCHEDULE SHEET K-2 AND REFRIGERATION PLAN. IF AUTOMATIC DEFROST SYSTEMS ARE USED FOR WALK-IN FREEZERS, PROVIDE A FIVE WIRE COLOR CODED SERVICE FROM COMPRESSOR TO BLOWER COIL AS DETAILED ON REFRIGERATION PLAN. 22, GENERAL CONTRACTOR SHALL FURNISH AND INSTALL "FUSED AND/OR NON -FUSED DISCONNECTS, AS REQUIRED BY LOCAL CODES. 23. GENERAL CONTRACTOR TO PROVIDE AND INSTALL VAPOR -PROOF LIGHTS AND SWITCHES FOR HOOD, AND CONDUIT TO HOOD LOCATION, UNLESS OTHERWISE INDICATED. s Imo' WALL MOUNTED SINGLE PURPOSE RECEPTACLE (FLUSH WITH FINISHED WALL } t3# WALL MOUNTED DOUBLE PURPOSE RECEPTACLE (FLUSH WITH FINISHED WALL ) VU WALL MOUNTED JUNCTON BOX (FLUSH WITH FINISHED WALL } °-0 EMPTY CONDUIT FOR COMMUNICATION CABLING (VERIFY POINT OF ORIGIN WITH ARCHITECT) PRE -WIRED EQUIPMENT TO J-BOX AND/OR SO -PANEL BY K.E.C. 75� ELECTRICAL POWER WHIP WITH 6-FOOT LONG LEAD (NO J-BOX) I LJ L_ __.- _ C Q 4 rJ DCO 38 01 � 1 1=_L'L'L'Jti • ICwi�IM�i,� �il� I I w.. cry _) N Q O -F - O `� 29 DCO DCO 120/1 / 10 AMP P 35 W f. 47 cum EQUIPMENT SCHEDULE ITEM DESCRIPTION MFG. MODEL # HW CW WASTE VOLT AMPS REMARKS 8 TRASH RECEPTACLE PLYMOLD 9 SODA MACHINE PEPSI/NAT°L. CARBONIC - 1/2' 3/4" REDUCED PRESSURE BACKFLOW DEVICE 10 BEVERAGE DESTINATION CENTER 11 RED NEON "OPEN" SIGN 120/1 20. 0 AMPS 14 CHIP RACK - 15 DISPLAY REFRIGERATOR 120/1 4. 7AMPS 18 GUIDANCE SYSTEM - - 19 FRONT COUNTER DUKE MFG. CO. 120/1 7.9/4.6 AMPS 22 DISPLAY REFRIGERATOR 120/1 20, 0 AMPS 23 SAFE BY OWNER - 24 SUSSHOP 2000 P.O.S, BY OWNER - 120/1 2. 0 AMPS 25 MICROWAVE (QTY. 2) AMANA RFS105W2 120/1 8. 3 AMPS 27 BREAD OVEN NUVU OP2-FM 1/2 208/3 21. 0 AMPS 28 ENCLOSED BREAD CABINET LOCKWOOD - 29 MENUBOARD AMERICAN SIGN - 31 BACK COUNTER W/ HAND SINK DUKE MFG. CO. 1/2" 1/2' 1-1/2" 32 BACK COUNTER DUKE MFG. CO. 101-1-1 33 REFRIGERTED BACK COUNTER DUKE MFG. CO. - 120/1 3. 8 AMPS 34 RAPID COOK OVEN 220/1 30, 0 AMPS 35 ICE MACHINE MANITOWAC SD-0592N 1/2' 3/4" 120/1 14. 7 AMPS 2. 3 AMPS ON ROOF 36 SINK L&B SHT. METAL - 1/2' 1/2' 1-1/2' 37 MOP SINK FLORESTONE MSR2424 1/2' 1/2' 3" CHICAGO #895 FAUCEET W/ VACUUM BREAKER 38 HOT WATER TANK (40 GAL.) RHEEM RUUD ELD40 3/4' 3/4' 3/4" 208/1 40. 0 AMPS 39 S.S. WORKTABLE DUKE MFG. 00. 3072 40 S.S. WALL SHELF DUKE MFG. CO. 43 CLEANING PRODUCTS RACK 45 SLICER NEMCO 46 RETARDER CABINET 47 REFRIGERATOR (UL / NSF) NORLAKE KL7486-CX-M 1 3/4" 1120/208/1 15. 0 AMPS FLASH TO CEILING & WALLS 48 FREEZER (UL / NSF) NORLAKE KL7766-CX-M 3/4' 120/208/1 15. 0 AMPS FLASH TO CEILING & WALLS 49 STORAGE UNITS 50 SODA STORAGE PEPSI/NAVL. CARBONIC - CHAIN TANKS TO WALL 51 STEREO `SYSTEM 52 AIR CURTAIN MARS AIR CURTAIN 120/208/11 5. 0 AMPS MICRO SWITCH TO RUN WHEN DOOR OPEN W U i' W (/) Z z O Uj ffal CO r- LT' ::) N cY) =1 LLl < C.) �z�Q o C�J U L.Li r�, L0 Li M I General Notes This plan and the designs herein are the sole property of JM and may not be reproduced, changed or used by anyone, In part or whole, without the written permission of a JM company officer. Any dewed deviations to this plan must be approved in writing bbyy JM before such work is done. It is the resppoonnss,�ta'iify of anyana using this plan to read and became familiar with of information shown hereon including any list of notes. Measurements on this plan are from available information, JM wig not assume any responsibility for the accuracy of such Information. Fobricators, contractors, etc. using this plan are to confam all Information on this plan with the job site. All information on this plan for the general contractor or the general con- tractor's subcontractors to perform (plumbing, electrical, cubs, walls, building openings, eto.) ore for the sole purpose of equipment requirements; reference is made to the owner or architectural plans for engineering or listing of Items not supplied by Jti. JM will not assume any respon- sibility for engineering thereof, All building work thereof shoes be by the gorwal contractor including all roughing -in and final connections and all runs to equipment and in- cluding all fittings or any other parts materials or labor for such work if any such work is in JM contact, A will speoifitcaly be indicated on this plan; if it is not specifically Indicated on this plop, 1 is not a part of JM contract and shall be provided by others. JM will assume no res xi biity for work done by the general contractor or a subcontractor of the general contractor or any changes mods necessary by local codes (including: Building, Health Depart ordinances, Fire Deport, eta.) or changes by the owns , architect or any other person ouMs of W with authority to the design, This plan becomes void upon such changes and work cannot be completed until the appropriate corrections are mode by JM. Using this plan is odmit- tonce that all information on this plan has been examined and compared with other plans (example: architectural plans) and any inconsistencies, errors, arnbiguRies or omis- sions have been reported to JM for written corrections before completing bids or commencing any work hereunder. No additional allowance will be made for such work unless it is agreed before acceptance of bids. Plumbing or electrical parts not supplied with the equipment as a standard item shalt be provided by the plumber or electrician unless specifically indicated on this plan. 03-25-05 SUBMITTAL DOCUMENT Date Revision/Issue H. I n to � z O v R d z = z I W li Z m 0 Ir w W � to z 0 z 0 U p K i r FOUR WAY SPLAY — BRACE WIRES AT HORIZONTAL RESTRAINT POINTS HANGER "RE FIRST POINT OF LATERAL FORCE BRACING SHALL NOT MORE THAN 12 FEET ON CENTERS BE WITHIN 6 FEET FROM EACH WALL 6'-0" MAX. -> IN BOTH DIRECTIONS TO FIRST HANGER WIRE CROSS RUNNER 4s: CONT. HORIZ. ACOUSTICAL PANEL STRUT TO PREVENT SPREADING OF RUNNERS 3AAW b11R11,1M _ 5" 5}i -WALL TRIM SIESMIC SECTION THROUGH ROOM NO %Ad CEILING & HVAC MATERIALS & INSTALLATION TO BE 4' 0" PER CBC SEC. 25 ELECTRICAL & LIGHTING TO BE INSTALLED PER 2001 CALIF. ELEC. CODE 2001 CBC SECTIONS 710.2, 803, 1630, 2501, 2502, 2504, AND 1997 UBC STD. 25.2 PER CODE SEC.1505 ATTICS OVER 30" WILL BE VENTED AND HAVE ADEQUATE ACCESS AREA r i G G A I i If N—A -0" I H I CEILING ClI I OD i IGF T HEIGHT iM r i o I , I )Cl I AH i HNG Ai ]I E G G i s1 CIA I— _ I L Ic 6'-0}> PRE-FAB 6}> FACTORY WIRED WALKIN REFER O LM EF CEILING HEIGHT 8'-0" AFF PRE-FAB FACTORY WIRED WAL FREE REFLECTIVE CEILINGPLANf -f GAFF CEILING HEIGHT NIGHT EX ST 'G T-BA V LI GHT 1 2 1/2" METAL STUD BRACING 0 4'-0" O.C. (ALTER DIRECTION) { f TO STRUCT, ABOVE. ATTACH (2) 1" 1 I SCREWS TO DECK ABOVE i I 4FT i I i I � k ACOUSTICAL CEILING WHERE OCCURS r— 3 5/8" METAL STUDS (UNO) S 25 GAUGE @ 16" O.C. TYPE'X} GYP. BD. 0 BOTH SIDES 1OFT —CONNECT PARTION TO CONC. FINISHED FLOOR FLOOR W/ 1" POWER ACTUATED r i i PIN @ 24" O.C. PARTITION WALL (TYPICAL) NO SCALE !i ALL NEW ROOF 11061610f *MENT TO HAVE .. E PENTRATIONS ONLY ..0 ir ; is l r PARAPET WALL CAL VERTICAL HANGER (TYPICAL) 3/4" C.W. SHUTOFF/THERMAL EXPANSION CONTROL VALVE TEMPERATURE PRESSURE RELIEF VALVE-150 PSI 2107 MAX. SETTING WEIGHT: 400#. APPROVED SEISMIC STRAPS W/2—#6 SCREWS TO STUDS 3/4" PLYWOOD PLATFORM JOISTS 3-5/8", 18 GA. STL. Q 8" STUD 3-5/8", 20 GA. STL. Q 8" 0. SINK CONNECT PARTITION TO CONC. FLOOR W/ 1" POWER ACTUATED PIN @ 12" OC. RATER HEATER PLATFORM. NO SCALE ITEM I FIXTURE DESCRIPTION TRIM LAMP A LIGHTOLIER REC. FLUOR. W/CLR. SECULAR REFL. (16) 8242HURM/ 8038CCLW ALZAK 2-32W B LIGHTOLIER POWERWASH T5-TRACK, W/2 54W, T6 MINI BI PIN FLUOR. FIXT. WHITE 54W. FLUOR. C PENDENT FIXT. (TO BE DETERMINED) 5OW. MR16 D COLUMBIA PRESCOLITE RECESSED WALL WASHER W/ ALZAK REFL. SH42C, H4. CLR. ALZAK 50W. PAR-3 F 1 x 4 SURFACE MOUNTED 23-TUBE FLUOR FIXT. W/ SHAT PROOF LENSE WHITE G CRAFTMADE FAN. CXL52FB W/ 85/ 52DBL OR EQUAL. POL. BRASS W/ NONE WALNUT BLADES H LIGHTOLIER REC. FLUOR . W/ CLR. LENSE. (9) 7132BURM/ 8037CCLW WHITE 1-32W I LIGHTOLIER #DPA2G9LP2FT120SB 2X2 2-LAMP 9 CELL PARABOLIC, ENERGY EFFICIENT BALLASTS I I T-5 LATERAL FORCES DETAIL NO SCALE Uj z ACIA �QI CO � ry =>M C�) W O M 0 0 m General Notes This on and the designs here n are the sole property of JM arrci may not be repraduced, changed or used by ayone, in part or whole, with the wrdtan permisson of a JM co."" officer. Any dewed dm4atiats to th s plan must be approved in 114 g by M before Re work is done . ft us the onsN 14 of anyo9this plan toreadecomeamiNa,with ail inashownhereon includ ng an l st oftes.Measureonthis planorefrom ovafable iaf me oJM will mt any respansib.Nty for the accuracy of such intonnakion. Fabricators, controctors, etc, using this plan are is confirm all information on this plan with the job site. All information on this plan for the general contractor or the general con tractor's subcontractors to perform {p�umbng, elac ca11 curbs, wails, building openings, etc.} are for the sale purpose of equipment requirements reference s made to the owner or orchitecturoi plans for engineering or I st ruJ of items riot suppNad by JM. will rat assume any Isspal- sibiNty for eMtginasrktg thereof. Al building work thereof shall be by the general contractor including ail rotuJttNpg-in and final ooarutctions and all suns to equ pment tmd in - Ow ng till fit2.11.01, ings ar any other parts mater als or labor for such work. If aiy such work is la %f contract, it wM spxifooNy be indicated on this plan: if it is not specifically incated on this plan, h is not a part of JM contract and shall be provided by others. JM will assume no responsibility for work done by the general contractor or a subcontractor of the general oantractor or arnf changes made necessary by local codes {including: i3uNrNng, Health Depart. ordinances, Fire Depart., etc.) or changes by the owner. architect or ann oMor person outsde uA wth authorty to the des gn. Ths plan becomes vo d upon such charges and work cannot be completed until the appropriate carnations are made by . usin I thus plan is admit- tance that all information%Aon th s plan has been examined and ,) m ored with other pions {excunple orchitecturai plans) and anq irtconsstenaes, errom, mnMgutes ar omis- s ons have been rsporied to JM for written corrections before carnpletng bids or commencing any work hereunder. No additional atbwanas will be mode for such work unless it is agreed before acceptance of bids. Plumbing or electrical parts rot supplied with the equipment as a standaM item shall be provided by the plumber or electrician uness specifically indicated on this plan. 06-23-05 LOG CLARIFICATIONS 03-25-05 UBMITTAL DOCUMENT Date Revision/Issue cL m w ui —i W w vzi 0 z z i r m 0 `y 11 x M to w Cal ca Q w O w z 0 CERTIFICATE COMPLIANCE (Part 1 of 3) °TG%—I PROJECT NAMESUBWAY DATE 6/10105 PROJECT ADDRESS 1701 MoFADDEN AVE, SANTA ANA, CA PRINCIPAL DESIGNER -LIGHTING TELEPHONE Building Permit # BRYAN CHADDICK (949) 651-9040 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date BRYAN CHADDICK 949 651-90401 Enforcement A_ciency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 1335 SO FT CLIMATE ZONE 8 BUILDING TYPE NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ®HO7ELIMOTEL GUEST PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ® ADDITION 0 ALTERATION ® UNCONDITIONED (fileaffidavt METHOD OF LIGHTING COMPLIANCE 0 COMPLETE BLDG. ❑ AREA CATEGORY ❑ TAILORED ❑ PERFORMANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications need to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNATURE DATE BRYAN CHADDICK 1 16/10)`05 The Principal Lighting Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in the applicable parts of Sections 110, 119, 130 through 132, 146, and 149 of Title 24, Part 6. Please check one: 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual,) PRINCIPAL LIGHTING DESIGNERS NAME I SIGNATURE DATE I LIC. # BRYAN CHADDICK 1 6/10/05 LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures T-24 INSTRUCTIONS TO APPLICANT For Detailed instructions on the use of this and a// Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. LTG-1: Required on plans for all submittals, Part 2 may be incorporated in schedules on plans. L TG-2: Required for all submittals. LTG-3: Optional. Use only if lighting control credits are taken, LTG-4ILTG-5: Optional. Use only if Tailored Method is used. Nonresidential Compliance Forms August 2001 COMPLIANCE SUMMARY LT,LIGHTING G-2 PROJECT NAME SUBWAY i}ATE 6/10/05 ACTUAL LIGHTING POWER LUMINAIRE TYPE NUMBER OF WATTS PER LUMINAIRE CEC DEFAULT? TOTAL NAME DESCRIPTION LUMINAIRES (including Ballast) Y N WATTS pA 4F32T8 6 110 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 660 B 2U31 13 54 702 C 2F32T8 1 54 54 D 2F32 4 54 216 E 50WMR16 10 50 500 F 2-54W FL 4 54 216 G 2F28T5 2 54 108 H 50WMR16 5 50 250 SUBTOTAL FROM THIS PAGE r 206_6_� PLUS SUBTOTAL FROM CONTINUATION PAGE PORTABLE LIGHTING (From LTG-1 Part 3 of 3) LESS CONTROL CREDIT WATTS (From LTG-3) ADJUSTED ACTUAL WATTS 206�_ ALLOWED LIGHTING POWER (Choose One Method) COMPLETE BUILDING METHOD BUILDING CATEGORY (From § 146(b) Table 1-M) WATTS COMPLETE ALLOWED PER SF BLDG. AREA WATTS AREA CATEGORY METHOD WATTS AREA ALLOWED AREA CATEGORY (From § 146(b) Table 1-N) PER SF (SF) WATTS TOTALS AREA WATTS �] TAILORS ) METHOD TOTAL ALLOWED WATTS 8857 -(From LTG-4) c # , ''I I FA INSTALLED?FROJECTNAME SUBWAY LIGHTING SCHEDULE LUMINAIRE DESCRIPTION- r ' f i (Part 2 of 3) LTG-1 In DATE 6/10105 TYPE rESCRIPTION .. .. - e - j ig Ing c e u e on Plans grows Exterior Lighrting Meets Efficacy and Control Requirement of §1301 ❑ Control Requirements of §131(f) i� �- • -. s .,r SUBTOTAL FROM THIS PAGE PLUS SUBTOTAL FROM CONTINUATION PAGE PORTABLE LIGHTING (From ITG-1 Part 3 of 3) LESS CONTROL CREDIT WATTS (From LTG-3) ADJUSTED ACTUAL WATTS TOTAL WATTS 660 702 54 216 50 216 108 250 1 2066 1 i (Room #) T IDENTIFICATION (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED FIELD TOILET MANUAL ENTIRE ^� OFFICE $ MANUAL ENTIRE PRM17111N1NG $$ MANUAL ENTIRE f i •, a • �Y•. M'. Nonresidential Compliance Form August 2001 (Part rr ! SUMMARY /" PROJECT NAME DATE SUBWAY 6/10/05 TAILORED ++ r; 1. Watts for Illuminance Categories A-D {from column G below} 11105�1055 WATTS 2. Watts for Illuminance Categories E-I (from LTG-4 Part 2) 1302 WATTS 3. Watts for Display Lighting (from LTG-4 Parts 2 & 3) 1+1 450 + - 450 WATTS Public Area Display Sales Feature Sates Feature Wall Floor Display Display 4. Total Allowed Watts (lines 1+2+3) 2857� WATTS TAILORED LPD - Illuminance Categories A, B, C and D and Groan Sales Flour Area � � � � � ill ROOM NUMBER TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD ALLOWED WATTS ExF STORAGE STORAGE C 3.4 286 .6 172 TOILET TOILET C 6.4 70 .7 49 SALES SALES G.S.A 3.4 442 2 884 AREA IE PAGE TOTAL BUILDING TOTAL — — — —T 1105 1 1335 1105 SF WATTS ?ORTABLE PROJECTSUi-. ii i 6/10/05 PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREA > 250 SQUARE FEET - .. OR ZONE 10 DEFAULT (WATTS) •- i r TABLE 1 B - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREA > 250 SQUARE FEET A B C D E F G ROOM # OR ZONE ID PORTABLE LIGHTING DESCRIPTION (S) PER TASK AREA LUMINAIRES (S) WATTS PER TASK AREA TASK AREA (SF) N UMBER OF TASK AREAS TOTALAREA (SF) (DxE) TOTAL WATTS (CxE) TOTAL TABLE I - PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE FEET ROOM # TOTAL AREA OR ZONE ID SF Designer need to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs of the space. the details include luminaire types, CU, and mounting locations relative to work areas. TOTAL BUILDING SUMMARY - PORTABLE LIGHTING TOTALAREA TOTAL BUILDING SUMMARY (SF) WATTS (FROM TABLES 1A+18+1C) (FROM TABLES 1A+1B) BUILDING TOTAL Enter on LTG-1 and 2: Portable Lighting TAILORED PROJECT NAME DATE SUBWAY 6110/05 TAILORED -i .•r. and Gross 0' MB © 0 © Q ALLOTTED WATTS WATTS ALLOWED WATTS (Min. G or K) TASK AREA (sf) -T ALLOWED LPD ALLOTTED WATTS (ExF) LUMIN. NAME _DESIGN QTY. Of LUMIN. --� WATTS/ LUMIN. DESIGN I WATTS I (IxJ) TASK I ACTIVITY Ilium. Cat. RCR (If E) _ Notes* KITCHEN E 2.8 537 2.31 1240 A 3 110 330 1052 D 3 54 162 GROSS SALES GSA — 260 2 520 H 2 108 216 WALL AREA J 4 54 216 G 4 32 128 K 5 50 250 PAGE TOTAL Enter Mounting Height . Throw -"_..-- ___m —.__ Distance if applicable. BUILDING TOTAL 1 ✓ 2 ,TAILORED LPD - Public Area Displays Lai ALLOTTED WATTS DESIGN WATTS TASK AREA (sf} - ALLOWED LPD ALLOTTED WATTS (DxE) LUMIN. NAME QTY, Of I LUMIN. WATTS{ LUMIN. C}ESIGN WATTS (Hxt) ALLOWED WATTS (Min. ForJ) TASK I ACTIVITY THROW DISTANCE MOUNT. HEIGHT TOTAL AREA PUBLIC DISPLAYS SF TOTAL WAI fS PLANE OF PUBLIC DISPLAY AREA x 0.1 = MAXIMUM AREA PUBLIC DISPLAYS (SF) ELECTRICAL MANDATORY Dq =#" till MEASURES BUILDING LIGHTING SHUT-OFF BUILDING LIGHTS ARE CONTROLLED THRU PROGRAMMABLE TIMER, 2. F"LUOURESCENT BLLAST AND LUMINAIRES CERTIFIED ALL FLOURESCENT FIXTURES SPECIFIED FOR THE PROJECT ARE CERTIFIED AND LISTED IN THE DIRECTORY, 3. TANDEM WIRING FOR TWO -LAMP BALLAST'S ALL ONE AND THREE LAMP FLOURESCENT FIXTURES ARE TANDEM WIRED WITH TWO C2) LAMP BALLASTS WHERE REQUIRED BY STANDARDS SECTTOh 132, OR ALL THREE LAMP FLOURESCENT FIXTURES ARE SPECIFIED WITH ELECTRONIC HIGH -FREQUENCY BALLASTS ARE EXEMPT FROM TWO -LAMP TANDEM WIRING REQUIREMENTS, 4. INDIVIDUAL ROOM/AREA CONTROLS EACH ROOM AND AREA IN THIS BUILDING IS EQUIPPED WITH A SEPARATE SWITCH, 5" UNIFORM REDUCTION FOR INDIVIDUAL ROOMS ALL ROOMS AND AREAS GREATER THAN 100 SQUARE FEET AND MORE THAN L2 WATTS PER SQUARE FOOT OF LIGHTING LOAD IS CONTROLLED WITH BI-LEVEL SWITCHING FOR UNIFORM REDUCTION OF LIGHTING WITHIN THE ROOM, • r: °G Li... V.13297 Exp, 3-31-06 �CTR OF CAL . TAILORED r 1, LPD # .r : , PROJECT NAME DIE SUBWAY 6/10/05 TAILORED LPD - Sales Feature Floor Displays ALLOTTED WATTS DESIGN WATTS TASK AREA M CAT, G ALLOWED LPD ALLOTTED WATTS (DxE) _ LUMIN. NAME CITY. Of LUMIN. WATTS/ LUMIN_ DESIGN WATTS (Hxt) ALLOWED WATTS (Min. For J) TASK 1 ACTIVITY THROW DISTANCE MOUNT. HEIGHT FLOOR DISPLAY 44 11.7 515 1 9 50 450 450 TOTAL AREA FLOOR DISPLAYS 44 SF TOTAL WATTS 1 450 GROSS SALES FLOOR AREA X0.1 MAXIMUM AREA FLOOR DISPLAYS (SF) ------- TAILORED LPD.;• - Displays - 0 Q '� QMi ALLOTTED WATTS DESIGN WATTS TASK AREA (sf) CAT. G ALLOWED LPD ALLOTTED WATTS (CXD) LUMIN, NAME CITY. Of LUMIN. WATTS/ LUMIN. DESIGN WATTS (GxH) ALLOWED WATTS (Min. E or 1) TASK 1 ACTIVITY THROW DISTANCE TOTAL AREA WALL DISPLAYS SF TOTAL WATTS GROSS SALES WALL AREA t x 0.1 = MAXIMUM AREA WALL DISPLAYS (SF) � r . Cn LtJ y Lij Cn Lj w(D CO CSN J (f) LLJ (J z M oLj _jV)co c) Generol Notes This plan and the designs herein ore the sate property of JA1 and may not be reproduced, or used by anyone, In part or whole, withaA written permission o a A company offder. Arty desired demations to this plan must be appmtiBd in writing by A before such wok is done. It is the responsibility, of anyone using this plan to read and became familiar with all information shown hereon Including any list of notes. Measurements on this plan are from avd6abie information. W will not assume spry b fRl for the accuracy of such information. rabiraatas, aanfraators, etc. using this plan ore to confirm all information on this plan with the job site. All infommtton on this plan for the general contractor or the general con— tractor's subcontractors to perform (phtmbing, atectrkal, curbs, walls, building openings, eta.) are for the sole purpose of equipment retpaimments; reference is reds to the owner or architecttrat plans for engineering or Isting of items not by A. JAi A net assume any respon— sibility for engineering thereof. AN building work thereof shall be by the general contractor Including all roughing —in and fool connections and all nuns to equipment and In— cknding all fittings or any other parts materials or labor for such work. N any such wok is in JM contract, H will specdkwgy be indicated on this plan; if A is not specifically ar this plan, it Is net o part of A contract aid shwa be pravkled by others. JM w assume no responsibility for work done by the general contractor or a subcontractor of the "wat oontroctor or any sdmnges made necessary by boat codas (irncidd ng gudCG. Health fle�rt oxLrmr ores, Pre t7epart , etc) ar chomJes by the owrrer, mcMteat a a� other posed outside of .ttt vnlh mittnoity to ttre dbsgn. This plan becomes void upon such aharnges and wok amrrot ba smmplated until the appropriote coractbns we remde by JM. Hsirog ttds plan b adnnit- taxnae ttwt oIi irdormatian an this pbn hers bean exonined and conparer! w1h other plans {•mmpb; mch'stecturot pion) and arty nconsistoncea, errors, ambgtdtes or omis— sions hoe been reported b JM for wdlten coreations before couplet ng bids or commencing any wok hereunder. No addollowonee will be made -for such work unless it is agreed before acceptance of bits. plumbing or electrical parts not supplied with the equipment as a standard item shah be provided by the plumber or electrician unless specifically indicated on this plan. 03-25-05 SUBMITTAL DOCUMENT Dote I Revision/Issue X d � w LU m ti z t3 to c$n W 4 t;- U z 0 w C14 z� ~ z z z 0 0 ran GENERAL CONSTRUCTION NOTES HEALTH DEPARTMENT NOTES FINISH SCHEDULE L K.E.C. PLANS ARE PROVIDED FOR THE PURPOSE OF INDICATING 1. SUBMIT SAMPLES OF WASHABLE CEILING TILE FOR APPROVAL PRIOR TO INSTALLATION, (SEE CEILING PLAN FOR SPEC.) MECHANICAL LOCATIONS AND EQUIPMENT REQUIREMENTS ONLY AND ARE NOT TO BE CONSTRUED BY THE GENERAL CONTRACTOR OR THE 2. ALL FLOOR SINKS ARE TO BE HALF EXPOSED OR BE IN LINE WITH SUBCONTRACTORS AS TO RELIEVE THEM FROM THEIR RESPONSIBILITY FACE OF ELEVATED FREESTANDING EQUIPMENT AND WITHIN 15 FEET CONDENSATE PRODUCING EQUIPMENT. NO. ROOM OF AREA FLOOR FLOOR BASE OR COVE WALLS CEILING CUSTOMER CROSSVILLE CERAMIC TILE SURFACE BULLNOSE BASE SUBWAY MURAL VINYL WALL 2 x 2 ACOUSTIC OF COMPLYING WiTH ALL APPLICABLE CODES. 2. iT SHALL BE THE RESPONSIBILITY OF THE OWNER AND/OR HiS ASSIGNED AGENT TO ENSURE THAT K.E.C. RECEIVES COPIES OF 3. ALL EXTERIOR AND RESTROOM DOORS ARE TO BE SELF CLOSING. 1 AREA POMPEII VS53, VS56, VS54 3' x 12' COVERING OVER TUSCAN LAY ill CEILING TILES ALL ADDENDUM AND CHANGES TO BUILDING PLANS WHICH ARE MADE PRIOR TO AND DURING CONSTRUCTION. IN THE EVENT THAT THIS 4. ALL EQUIPMENT MUST BE SUPPORTED BY A MIN. 6" HIGH LEGS, COMMERCIAL CASTERS OR BE COMPETELY SEALED STUCCO VINYL WALL COVERING SELF --SERVE CROSSVILLE CERAMIC TILE 6"x 12" SUBWAY MURAL VINYL WALL 2 x 2 WASHABLE INFORMATION IS NOT DELIVERED TO K.E.C., OWNER WILL BE IN POSTION ON A 6" HIGH CONTiNOUS COVED BASE. f �� RESPONSIBLE FOR ALL COSTS INCURRED BY THE FAILURE TO GiVE F.S.E.C. THIS INFORMATION. 5. NSF STANDARDS ARE USED AS THE GUIDE FOR EQUIPMENT EVALUATION. ��-�-1) AREA POMPEII VS53, VS56, VS54 SANITARY COVE BASE COVERING OVER TUSCAN LAY IN CEILING TILES STUCCO VINYL WALL COVERING 3. GENERAL CONTRACTOR SHALL PROVIDE PROPER BACKING FOR ALL WALL HUNG EQUIPMENT, SHELVING, ETC., AS INDICATED ON WALL 6. ALL PLUMBING, ELECTRICAL & GAS LINES SHALL BE CONCEALED WITHIN BUILDING STRUCTURE TO AS GREAT AN CROSSVILLE CERAMIC TILE 6"x 12" SEMI -GLOSS PAINT DUNN- BACKING DETAIL. EXTENT AS POSSIBLE. PUBLIC RESTROOM POMPEII VS53, VS56, VS54 SANITARY COVE BASE MARLiTE FRP TO 8 FT. AFF EDWARDS COTTAGE WHITE 4. GENERAL CONTRACTOR SMALL BE RESPONSIBLE FOR ALL GENERAL 7. 1 " HORIZONTAL RUNS OF DRAIN LINES SHALL BE AT LEAST FROM THE WAIL & 6" OFF THE FLOOR AND SHALL CLEANUP AND DISPOSAL OF ALL TRASH, CARTONS, CRATES, DEBRIS, ETC., AFTER FINAL INSTALLATION OF ALL FIXTURES. TERMINATE AT LEAST AT LEAST 1" ABOVE THE OVERFLOW RIM OF THE FLOOR SINK. 5. SPRINKLER HEADS IN WALK-IN FREEZER AND COOLER ROOMS WILL BE SUPPLIED BY AND ADEQUATELY PROTECTED AGAINST FREEZING UP BY 8. ALL LAVS & HAND SINKS WILL HAVE A COMBINATION OR PREMIXING FAUCET CAPABLE OF SUPPLYING WARM FIRE SPRINKLER CONTRACTOR. WATER FOR A MIN. OF 10 SECONDS. 6. PLUMBERS AND ELECTRICIANS AND ALL OTHER TRADES INVOLVED j� \ KITCHEN AREA EPDXY 6" EPDXY COVE TILE. DAL TILE X735 ALMOND Wj 2x2 DECO PATTERN WASHABLE CEILING TILE MUST CONFORM TO APPLICABLE CODES. 9. JANITORIAL SINK IS TO BE PROVIDED W/ AN APPROVED BACKFLOW DEVICE. (� j l--f W/ 3j8" RADUIS COVE @ 7 FT. AFF 7. HVAC CONTRACTOR TO ENSURE ALL EXHAUST FANS WILL BE CAPABLE OF DELIVERING CFM REQUIREMENT AS NOTED ON PLANS. K.E.C. 10. ALL SHELVING OVER WET AREAS (SINKS, ETC.) TO BE STAINLESS STL. 6" EPDXY COVE IS NOT RESPONSIBLE FOR ANY OBJECTIONAL ODORS OR SMOKE STORAGE AREA EPDXY W/ 3/8" RADUIS COVE FRP WASHABLE CEILING TILE DELIVERED INTO THE SURROUNDING AREA. HVAC CONTRACTOR TO BALANCE EXHAUST, MAKE-UP AIR AND AIR CONDITIONING. 11. OUTSIDE TRASH AREA HAS CONCRETE SLAB AND SMOOTH FINISH BLOCK WkLLS THAT ARE SEALED AND WASHABLE. JANITORIAL AREA EPDXY 6" EPDXY COVE W/ 3/8" RADUIS COVE FRP WASHABLE CEILING TILE & IF WALK-IN LOW TEMPERATURE AND NORMAL TEMPERATURE REFRIGERATION 1Z EXHAUST FAN IN TOILET ROOM IS TO PROVIDE 12 AIR CHANGES PER HOUR AND IS ACTIVATED W/ LIGHT SWITCH. ROOMS ARE BUILT-IN TYPE, INSULATION AND PROPER VAPOR BARRIER, 7 INTERIOR LIGHTS AND SWITCHES (INSIDE AND OUTSIDE), SPRINKLERS AND INTERIOR 13. FINISH IS BY GENERAL CONTRACT, NOT USED 9. IN EVENT RACEWAY IS INDICATED ON CURB PLAN, THE GENERAL 14. HOT WATER HEATER IS 40 GAL„ 9 KW HiGH RECOVERY. EMPLOYEE EPDXY 6" EPDXY COVE FRP WASHABLE CEILING TILE CONTRACTOR TILL BACKFILL EXPOSED AND ACCESSIBLE OPENING OF (D LOCKER AREA W/ 3/8" RADUIS COVE RACEWAYS AND OTHER EXCESSIVE OPENINGS AFTER INSTALLATION OF FIXTURES TO PREVENT VERMIN INFESTATION. 15, ALL REQUIRED SNEEZE GUARDS WILL COMPLY W/EHP-885 REQUIREMENTS. 16. FLOORING TO SELF-COVING 6" HIGH W/ 3/8" MIN. RADIUS. OFFICE EPDXY 6" EPDXY COVE FRP WASHABLE CEILING TILE 10. SWINGING DOORS IN PASSAGEWAYS SHALL BE PROVIDED WITH WINDOWS (9 } W/ 3/8" RADUIS COVE WHICH SHALL BE 8" X 24" OR OF A SUBSTANTIAL EQUIVALENT AREA 17. SUBMIT CONCRETE SEALANT SPECIFICATIONS TO HEALTH DEPT, FOR APPROVAL. LIGHT NONSLIP FINISH IS APPROVED 1 TO MEET OSHA REQUIREMENTS. THE GLASS SHALL BE EITHER ONLY IN TRAFFIC AREAS, SURFACES UNDER EQUIPMENT TO BE SMOOTH. SHATTERPROOF OR WIRE GLASS AND THE BOTTOM OF THE WINDOWS SHOULD NOT BE MORE THAN 48" ABOVE THE FLOOR, 18. SHATTER SHIELDS TO BE PROVIDED ALL LIGHTS ABOVE FOOD PREPARATION, WORK & STORAGE AREAS. 10 WALK EPDXY 6" EPDXY COVE BASE GALVANIZED METAL GALVANIZED METAL FLASHED TO T-BAR ABOVE COOLEERR 11. GENERAL CONTRACTOR TO CUT OR PROVIDE HOLES THROUGH CEILING, 19. A MINIMUM OF 20 FOOT CANDLES OF LIGHT 0 30" ABOVE FIN. FLR. IN FOOD PREP., PACKAGING , PROCESSING ROOFS AND WALLS FOR DUCTS, ETC., IN ACCORDANCE WITH LOCAL AND UTENSIL CLEANING AREAS, WALK-IN GALVANIZED FLOOR GALVANIZED METAL FIRE AND BUILDING CODES AND IN ACCORDANCE WITH DUCT SIZES SPECIFIED BY E.5.E.C, GENERAL CONTRACTOR ALSO TO PROVIDE 20. PROVIDE A MIN. OF 10 FOOT CANDLES OF LIGHT 0 30" ABOVE FIN. FLR. IN ALL STORAGE & TOILET ROOMS. 11 FREEZER S jS FLOOR W/ 3/8" RADUIS COVE GALVANIZED METAL FLASHED TO T-BAR ABOVE All MOT FIRF SFPARATIONS. FNCI CSSURFS. WRAPPINGS. SPRINKLER SYSTEM, ETC., AS MAY BE REQUIRED BY LOCAL BUILDING AND FIRE CODES. 11 PLUMBING AND/OR ELECTRICAL FINAL CONNECTIONS AND INTERNAL WIRING AND PLUMBING OF EQUIPMENT AND FIXTURES INDICATED ON THESE PLANS ARE NOT PART OF K.E.C. CONTRACT AND ARE TO BE DONE BY G.C. 13. ALL CANTILEVER BRACKETS FOR TABLES AND STOOL SEATS OR OTHER EQUIPMENT TO BE PROVIDED BY K.E.C. BUT INSTALLED BY GENERAL CONTRACTOR AND SHALL BE INSTALLED IN ACCORDANCE WITH SPECIFICATIONS AND DIMENSIONS PROVIDED BY F.&E.C. GENERAL CONTRACTOR TO PROVIDE PROPER BACKING FOR SUPPORT BRACKETS, 14. MAKE-UP AIR: THE MAKE-UP AIR SYSTEM SHALL HAVE A SUFFICIENT CAPACITY TO MAKE UP 100% OF THE AIR BEING EXHAUSTED AND SHALL BE BALANCED TO MAKE-UP UP TO 90% OF THAT AIR. MAKE-UP AIR GRILLS SHALL BE EQUIPPED WITH KEY OPERATED OPPOSED BLADE VOLUME CONTROLS. MAKE-UP AIR GRILLS SHALL BE EQUIPPED FOR MAXIMUM OUTLET VELOCITY OF 400 FPM. MAKE-UP AIR SHALT BE DELIVERED IN THE PROXIMITY OF THE EXHAUST SYSTEM IN A MANNER NOT TO CREATE UNIQUE AIR TURBULENCE IN THE WORKING AREA. MAKE-UP AiR SYSTEM SHALL BE CAPABLE OF DELIVERING AIR AT 70 DEGREES. 15. UNLESS OTHER PROVISIONS ARE MADE AND/OR INDICATED ON PLAN, GENERAL AND/OR HVAC CONTRACTOR TO PROVIDE TEMPERED MAKE-UP AIR FOR EXHAUST HOODS IN ACCORDANCE WITH REQUIREMENTS INDICATED (NOTE #16) 16, G.C. TO ENSURE WALL LAMINATE IS FIRST ADHEARED TO A SUBSTRAITE PRIOR TO BEING INSTALLED ON THE WALL. G.C. TO ENSURE LAMINATE BRAND INSTALLATION INSTRUCTIONS ARE FOLLOWED AND THESE INSTRUCTIONS WILL SUPERCEDE ANY NOTATIONS ON THESE PLANS. 17. ALL ENCLOSED PORTIONS OF BUILDINGS CUSTOMARILY OCCUPIED BY HUMAN BEINGS SHALL BE PROVIDED WITH A MECHANICALLY OPERATED VENTILATION SYSTEM. SUCH MECHANICALLY OPERATED VENT SYSTEM SHALL BE CAPABLE OF SUPPLYING A MIN. OF 15 CU. FT PER MIN OF OUTSIDE AIR PER OCCUPANT DURING SUCH TIME AS THE BUILDING IS OCCUPIED. IF THE VELOCITY OF AIR AT A REGISTER EXCEEDS 10 FT PER SECOND, THE REGISTER SAHH BE PLACED MORE THAN 8 FTEET ABOVE THE FLOOR DIRECTLY BENEATH. CBC SECTION 1202.2.1 r 1 w slr � r � r r LI. ALL MLR3 Vr IFIL rRLnLIII MRL IV rRVYIULU IT/ IV rVVI VNtlULLJ Vr FJVrii W JV TUVYL IM- IL". DURING CLEANUP ACTi)ATIES. 22. ALL 2 & 3 COMPARMENT SINKS ARE TO HAVE A MIN. COMPARTMENT SIZE OF 18"x 18"x 12" DEEP OR 16"x 20"x 12" DEEP, W/ DRAIN BOARDS 18" WIDE 0 EA. END & A MIN. OF 8" INTREGAL BACK SPLASH 0 ALL WALLS. 23, ALL SERVICE iS IN DISPOSABLE CONTAINERS & UTENSILS. 24. NO ALCOHOLIC BEVERAGES ARE SERVED. 25, TOWEL AND SOAP DISPENERS ARE TO PROVIDED 0 HAND SINK. 26, ALL NEW SINKS ARE TO PROVIDE HOT & COLD WATER THROUGH MIXING FAUCETS AT A CONSTANT MIN, TEMP. OF 120 PER CODE. 27. ONLY SINGLE SERVICE UTENSILS TO BE USED. 28. MAXIMUM NUMBER OF EMPLOYEES ON ANY ONE SHIFT = 3. 20, EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, CBC SECTION 1003.3.1.8 1. Grab bar to be 33" above and parallel to the floor. 2. Side grab bars to be 42" long and project 24" in front of the water closet stool. Grab bar at back to be 36" long. 3. Diameter of grab bars to be 1- 41" to 1- 2". 4. Provide I-l" clearance between grab bars and wall. 5. Grab bars (including connectors,fosteners, support backing, etc.) shall be designed to support a 250 # load. 6. Grab bars shall not rotate within their fittings, 7. Grab bars are to be located on each side or on one side and back of water closet. & Grab bars shall comply with CBC section 1115b.8 and have a 2501b point load. 1. Provide a clear floor space 30" by 48" in front of lavatory to permit a forward approach. 2. Minimum 29" clear from floor to bottom of apron with knee. 3. Provide a dear space beneath the lavatory 27" high by 30" wide by 8" deep at the top and 9" high by 30" wide by 17" deep at the bottom. 4. Hot water and drain pipes under lavatory to be insulated or covered and be free of sharp or abrasive surfaces. 5. Faucet controls and operating mechonisims (operable with one hand) shall be of the type not requring tight grasping, pinching or twisting of the wrist, or on operating force exceeding 5 pounds. 6. Self closing valves permitted if faucet remains open for at least 10 seconds. 1. The height of the water closet (top of seat) shall be between i7 and 19 inches, 2. Flush controls to be operable by an oscillating handles with a maximum force of 3 pounds. URINALS 1. Urinals shall have rims projecting a minimum of 14" from the wall and the rims shall be within 17" of the floor. 1. Bottom edge of mirrors to be no higher than 40" from the floor. 2. Toilet tissue dispensers to be mounted within 12" from the front edge of the toilet seat. 3. Operating parts of dispensing and disposal fixtures (towel, sanitary napkins, waste, coin slots, etc.) are to be with -in 40" from floor 1. There shall be sufficient space in the toilet room for a wheel chair measuring 30" wide by 48" long to enter the room and permit the door to close. 2. The water closet shall be located in a space which provides a 28" wide clear space from a fixture or a 32" wide clear space from a wall at one side and 48" of clear space in front of the water closet. 3. Doors to the toilet facility shall be identified by f " thick geometric symbols of contrasting color and centered on the door at a ht. of 60"; 12" equilateral triangle for men and 12" dia. circle for women. EQUIPMENT SCHEDULE ITEM DESCRIPTION MFG, MODEL # HW CW WASTE VOLT AMPS REMARKS 8 TRASH RECEPTACLE PLYMOLD - H9 SODA MACHINE PEPSI/NAT'L CARBONIC - 1/2" 3/4" REDUCED PRESSURE BACKFLOW DEVICE 10 BEVERAGE DESTINATION CENTER 11 RED NEON "OPEN" SIGN 1 120/1 20. 0 AMPS 14 CHIP RACK 15 DISPLAY REFRIGERATOR - - 120/1 4. 7MMPS 18 GUIDANCE SYSTEM 19 FRONT COUNTER DUKE MFG. CO, 120/1 7.9/4.6 AMPS 22 DISPLAY REFRIGERATOR 120/1 20. 0 AMPS 23 SAFE BY OWNER 24 SUBSHOP 2000 P.Q.S. BY OWNER - 120/1 2. 0 AMPS 25 MICROWAVE (OTY: 2) AMANA RFS105W2 120/1 8. 3 AMPS 27 BREAD OVEN NUVU OP24M 1/2" 208/3 21. 0 AMPS 28 ENCLOSED BREAD CABINET LOCKWOOD - 29 MENUBOARD AMERICAN SIGN 31 BACK COUNTER W/ HAND SINK DUKE MFG. CO. 1/2" 1/2" 1-1/2" 32 BACK COUNTER DUKE MFG. CO. 101-1-1 33 REFRIGERTED BACK COUNTER DUKE MFG, CO. - 120/1 3. 8 AMPS 34 RAPID COOK OVEN 220/1 30, 0 AMPS 35 ICE MACHINE MANiTOWAC SD-0592N 1/2" 3/4" 120/1 14. 7 AMPS 2. 3 AMPS ON ROOF 36 SINK L&B SHT. METAL - 1/2" 1/2" 1-1/2" 37 MOP SINK FLORESTONE MSR2424 1/2" 112" 3" CHICAGO #895 FAUCAET W/ VACUUM BREAKER 38 HOT WATER TANK (40 GAL) RHEEM RUUD ELD40 3/4" 3/4" 3/4" 208/1 40. 0 AMPS 39 S.S. WORKTABLE DUKE MFG. CO. 3072 40 S,S, WALL SHELF DUKE MFG. CO. 43 CLEANING PRODUCTS RACK 45 SLICER NEMCO 46 RETARDER CABINET 47 REFRIGERATOR (UL / NSF) NORLAKE KL7486-CX-M 3/4" 120/208/1 15, 0 AMPS FLASH TO CEILING & WALLS 48 FREEZER (UL / NSF) NORLAKE KL7766-CX-M 3/4" 120/208/1 15. 0 AMPS FLASH TO CEILING & WALLS 49 STORAGE UNITS 50 SODA STORAGE PEPSI/NATL CARBONIC - CHAiN TANKS TO WALL 51 STERO SYSTEM FOR SCHEDULE ITEM DESCRIPTION (A) 3'-0" x 6'-8" SOLID CORE DOOR ON TIMELY METAL FRAMES LEVER HARDWARE (B) S-O" x 7'-0" STORE FRONT GLASS DOOR. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGTH ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARD. CBC SECTION 11338.2.5 ALL DOORS SHALL BE SMOOTH AND HAVE A UNINTERRUPTED SURFACE 10 INCHES FROM BOTTOM. SHEETINDEX SHEET NO. DESCRIPTION KO.1 COVER SHEET K1.1 EQUIPMENT PLAN AND NOTES K2.1 PLUMBING / ELECTRICAL ROUGH -IN PLANS K3,1 j REFLECTED CEILING PLAN/ CONSTRUCTION PLAN PLAN ORANGE #i # 5 rg,am+ p4 44 REVIEW3.) f ry ,4E N V I R O ICI k1 ENT! X-4"c �? .II '�; .,'. ,Wsiv.. tI l r F"f t �. �"yi (714f 6 F'ai 13f I f PLAN REVIEV'� BY THESE PLANS AND I tt !F PEEN REViEW;VED AND CORRECTIONS. JHANG- g ARE INDICATED ON THE PLANS AND A"a TACUIH T) LETTER THIS APPROVAL DOES NOT CONSTITUTE AUTHORITY TO VIOLATE ANY PROVISION OF THE REL F:D CODES, ORDINANCES OR REGULATIONS NOR DO' S IT PRE- VENT FURTHER CORRECTION OF ERRORS i~OUND ON THE PLANS OR INSTALLATION UPON FIELD INSPECTION. ANY ALTERATIONS OR CHANGES IN CONSTRUCTION FROM THESE PLANS MUST HAVE PRIOR APPROVAL 64 THIS AGENCY. A COPY OF THESE PLANS MUST BE KEPT ON THE JOB' SITE AT ALL TIMES, REFER TO THE LOCAL BLDG. DEPT. FOR PLAN AP PROVAL AND PERN'11`I S 1-110,R TO CONSTRUCTION. i- UCTION. THIS �@ f s s 81s:.,R t` .:r F.. ORANGE NOTICE 11 Iff CARE! N CV ENV, TAL HEALTH I3.T°TI T~ CTIOI�T� RR�.`L.tZ.11�T1�R A?3 T°Z�-h1t�% INSPECTIONS AR RE QUIRET r T1Ii�lG TIDE CONSTRUCTION OF THE COI a E ! CILI �'. 11TSI3ECT?0NS ARE TO 13E AIRRANGa D AT LEAST 2 WORMING DAYS IN ADVANCE. PHONE: (714) 66 -373 vl'_o„ 4» ¢„ MONISM/ _ ks:wa:10! GENERAL NOTES- - CEILING HEIGHT IS 8'7" - ELECTRICAL OUTLET HEIGHTS MEASURED TO BOTTOM OF BOX. - ONE ELECTRICAL JUNCTION BOX TO BE LOCATED IN CEILING ABOVE EACH WINDOW. - STORE DESIGNED WITH CONTOUR SEATING. SHOWN ON PLAN AS SINGLES NOT GROUPS. - CUNO MODEL SW3-EL-1H WATER FILTRATION SYSTEM IS REQUIRED IN ALL NEW STORES THAT DISPENSE BEVERAGES (IN CANADA THE ECOLAB FRESH H2O REMAINS OPTIONAL). THE RECOMMENDED PLACEMENT FOR INSTALLATION iS REMOTE MOUNTING ONTO THE BACKROOM BEVERAGE SYRUP RACK OR MOUNTING ONTO BACKROOM WALL. OPTIONAL INSTALLATION MOUNTING INSIDE THE FRONT BEVERAGE COUNTER WHERE SPACE LIMITATIONS OCCUR. IN AREAS WHERE CHLORAMINE IS IN USE BY THE LOCAL MUNICIPALITY THE CUNO MODEL CFSCRC CANISTER IS REQUIRED TO BE INSTALLED IN ADDITION TO THE STANDARD SW3-EL-1H SYSTEM. REQUIRED: 1/2" INCOMING WATER LiNE FEED WITH 1/2" BALL VALVE SHUTOFF AND 1/2" FPT CONNECTION. MINIMUM 110 VOLT, 20 AMP ELECTRICAL SERVICE TO SUPPORT THE CARBONATOR AND WATER BOOSTER (MUST BE DEDICATED CIRCUIT). - PROMOTIONAL FLOOR STAND (MFR. TRANS WORLD) REQUIRED IN CUSTOMER AREA AT POiNT OF ORDER (PREFERRED PLACEMENT). 14 1 12" X 10" BASE, 54" OVERALL HEIGHT. - EXIT LIGHTS INSTALLED BY G.C. PER LOCAL CODE. - EMERGENCY LIGHTS INSTALLED BY G.C. PER LOCAL CODE. - EXTINGUISHERS, SMOKE AND FIRE DETECTION SYSTEMS INSTALLED BY G.C. PER LOCAL CODE. - LABOR &c MATERIAL SUPPLIED BY G.C. UNLESS OTHERWISE NOTED. - ALL DIMENSIONS TO BE VERIFIED BY G.C. ON SITE. - DECOR SPECIFICATIONS ARE TO BE SUBWAYS "TUSCANY" SCHEME. to General Notes This plan and the designs herein are the a* property of JM and may not be reproduced, changed or used by anyone, m part or wbols, without the written permission a a JM company officer. My dared deviations to -this Nan must be approved in writing by JM before such work is done. it is the responsibility of anyone using this pan to read and become familiar with all information shown hereon Including any list of notes. Measurements on this plan are from available information. JM will not assume arty resp risibility for the accuracy of such information. Fo .tars, contractors, etc. using this plan are to confirm oil infomoton on this plan with Ehe job site. NI information on this plan for the general contractor or the general con- tractor's subcontractors to perform (plumbing, electrical, curbs, wails, building openings, eta.) one for the sob purpose of equplm>ent requsemelrts reference is made to the owner or architectural plans for engineering or fisting of items not Zied a JM will not asrbmro ally ropam- y angineering thereof. All building work thereof $haA be by the general contractor including all roughing -in and final oanneciions and all runs to equipment and in- cluding all fittings or any other parts matelots or labor for such work, M any such work is in ,Mil contract, (t will spe ifroolly be indicated on this plan: V A is not specifwoiy irMicated on ttas , i is fad a pork of JM oantract and sham be provided by otnsrs. JM witi assisnte no rssponsib ity for work flame by the geForol contractor or a sulbaoMractor of the general contractor or arty changes made necessary by Eoaai Lodes (inakrdtng: Building, Health Depart. ord nances, Fre Depart , eta.} or ahangas by the owner, arctidecE err o oMm� parson outsab of J wF�l authority to Bme This plan becomes veld upon such changes araf work cannot be completed anti tfie appropriate corracUons ore. made by JM. Wising this Nan is odmlt- to®r" that all informotion on this pan has basin exomined and compared with other plans (examN9: architectural plans) and any inconsistencies, errors, ambiguities or omis- sions hove been reported to N for written corrections before completing bids or eommenaing any work hereunder. No additional allowance will be mach for such work unless It is agreed before acceptance of bids, Plumbing or electrical parks not supplied with the equipment as a standard ter shall be provided by the plumber or electrician unless specifically Indicated on this plan. 03-25-05 SUBMITTAL DOCUMENT Date Revision Issue :ry a.� tl. 1 Irr Q wit°° r I-- Z W CL. � as �1 z W T cn � z c7 u � 0 I z z Z rb " W C,$ � M 0 w 0