Loading...
HomeMy WebLinkAbout10149976.pdf1. ALL CONSTRUCTION SHALL CONFORM TO 2001 CALIFORNIA BUILDING CODE, 2001 CALIFORNIA PLUMBING CODE, 2001 CALIFORNIA MECHANICAL CODE, AND THE 2001 CALIFORNIA ELECTRICAL CODE. 2. CONTRACTOR/BUILDER SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK t SHALL NOTIFY ARCHITECT AND/OR ENGINEER OF ANY DISCREPANCIES IMMEDIATELY. 3. CONTRACTOR/BUILDER TO VERIFY ALL DIMENSIONS. 4. DO NOT SCALE DRAWINGS. 5. ALL FRAMING LUMBER TO BE CONSTRUCTION GRADE D.F. 02 OR BETTER 6. COORDINATE ALL FINISH COLORS AND MATERIALS WITH EXISTING. 1. SLIDING GLASS DOORS t WINDOWS LOCATED LESS THAN I&FT. ASV. ANY SURFACE AVAIL. FOR PUBLIC USE SHALL BE CAPABLE OF BEING LOCKED SECURELY. MOVABLE PANELS SHALL NOT BE EASILY REMOVED FROM THE FRAME. S. PROVIDE SAFETY GLASS WHERE REQUIRED BY USG SECTION 2406.4. S. ALL NEW WINDOWS AND DOORS TO BE DUAL GLAZE, LOWE GLASS MAX U-FACTOR 0.15. 10. INSULATION SHALL BE R13 IN ALL NEW WALLS AND RIS IN ALL CEILINGS. UNLESS OTHERWISE NOTED. If. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM 15YPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. 12. AS THE ARCHITECT/ENGINEER OF RECORD, I HAVE SELECTED APPROPRIATE BEST MAMAGEMENT PRACTICES (SMPS) TO EFFECTIVELY MINIMIZE THE NEGATIVE IMPACTS OF THIS PRROJECT°S CONSTRUCTION ACTIVITIES ON STORM WATER QUALITY. THE PROJECT OWNER AND CONTRACTOR ARE AWARE THAT SELECTED BMPS MUST BE INSTALLED, MONITORED AND MAINTAINED TO ENSURE THEIR EFFECTIVENESS. THE SMPS NOT SELECTED FOR IMPLEMENTATION ARE REDUNDANT OR DEEMED NOT APPLICABLE TO THE PROPOSED CONSTRUCTION ACTIVITIES. A/C AIR CONDITIONING PL. PLATE A,F,F. ABOVE FINISH FLOOR P.L. PROPERTY LINE AMT. AMOUNT PLYWD, PLYWOOD APPROX APPROXIMATE PR, PAIR AVG. AVERAGE QTY QUANTITY BD. BOARD R. RISER BTWN. BETWEEN RAD. RADIUS BLDG BUILDING RD. ROAD, ROUND BLK., BLKG. BLOCK, BLOCKING REFR, REINF. REFRIGERATOR REINFORCING, REINFORCE CHG. CLG CHANGE CEILING REQ. REQUIRED Cl, CENTER LINE REV. REVISED, REVISION COL. COLUMN RM. ROOM CONC. CONCRETE R.O. ROUGH OPENING CTR. CENTER R.V. ROOF VENT DBL. DOUBLE S. SOUTH DIA. DIAMETER SCHED. SCHEDULE DIM. DIMENSION S.C. SOLID CORE D.S. DOWN SPOUT SECT. SECTION DW. DISHWASHER SHR. SHOWER (e) EXISTING SHT, SHEET EA. EACH SIN. SIMILAR ELEC. ELECTRIC SPEC. SPECIFICATION V ELEVATOR SQ.FT. SQUARE FOOT EQ.ELE EQUIP, ELEVATION, EQUIPMENT ST, STAIR(S), STREET EXIST, (E) EXISTING STD. STANDARD EXT. EXTERIOR STOR. STORAGE FIN. FINISH STRUCT, STRUCTURE, STRUCTURAL FL. FLOOR T. TREAD FLUOR. FLUORESCENT TEL. TELEPHONE FT, FTC. FOOT FEET FOOTING TEMP. TEMPERATURE GYP. GYPSUM TA G. TONGUE AND GROOVE H.B. HOSE BIBB THK. THICK MDR. HDW. HEADER HARDWARE TV, TELEVISION HT. HEIGHT TYP. TYPICAL N, INCH UNFIN, UNFINISHED INSULATE, INSULATION U.O.N. UNLESS OTHERWISE NOTED IN S. IN T. INTERIOR VENT. VENTILATE, VENTILATING JUNCTION KITCHEN VERT. VERTICAL LAV. LAVATORY W. WEST LIN. LINEAR W.C. WATER CLOSET LT. LIGHT WD. WOOD MAT. MAX, MATERIAL MAXIMUM WDO WINDOW MANUFACTURER W.H. WATER HEATER MIN MINIMUM W/ WITH MISC MISCELLANEOUS W/I WITHIN N N0 NUMBER W/O WITHOUT O.C. ON CENTER A.N.S.I, AMERICAN NATIONAL STANDARDS INSTITUTE A.S.T.M. AMERICAN SOCIETY FOR TESTING AND MATERIALS I.C.B.O. INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS N.F.P.A. NATIONAL FIRE PROTECTION ASSOCIATION D.S.A. DIVISION OF THE STATE ARCHITECT O.S.H.A. OCCUPATIONAL SAFETY AND HEALTH ACT U.B.C. UNIFORM BUILDING CODE U.L. UNDERWRITERS' LABORATORIES, INC. U.F.C. ,UNIFORM FIRE CODE W.I.C. " WOODWORK INSTITUTE OF CALIFORNIA m z 01 r-03 Z4 2 m d rapu w OWNER: DAVID 4 5AR5ARA PIEC!- OTA SITE ADDRESS: SIO E. AVALON AVE LOT 0 TRACT` CITY: SANTA ANA COUNTY: ORANGE STATE: CALIFORNIA OCCUPANCY: R-3 ZONING: R-I-N CONSTRUCTION TYPE: TYPE V - NON RATED ADDITION TO EXIST"G RESIDENCE EXISTING RESIDENCE 1534 Sr-. EXISTING GARAGE 354 S.F. NEW ADDITION: 25ra SF. TOTAL NEW RESIDENCE: 1"190 S.F. TOTAL GARAGE: 354 Sr-. TOTAL SF.: 2144 Sr-. PROJECT DESCRIPTION ENGINEERING OLAN GUIREY, P.E. 8SOI WARNER AVE. HUNTING -TON BEACH, CAA mm h.. x :m 1 AALL R AVALON AVE LY 60.23" W I — LOT COVERAGE TOTAL LOT S.F.: '1060 S.F. PROPOSED COVERAGE 309p IRWIN 5ERNARDO ENERTECH 6126 :. • DOWNEY, CA S0242 310.314.2441 ARCHITECTURAL STRUCTURAL ACCEPTED FOR CONSTRUCTION AR IREQU D FOR ELECTRICAL, :glN.11 ICA PLANS This get of p4rdloo kwp3 o tale job at s s`3. a. 3g``r',Fxu,�"3 a $"r ;A.� �,5 $t tax* `p gyp � Mimi m s or tO t ! Sa s�°i aq�gg' A4,4a�'€. �.� $Ics a � v a�� s' �� �' "�pf 8f x, c .�4'd a � n €? 1 �mw l of Ol> i mike w s laic Law. A By aY u � ��fW-,!E� ' M NIA 9 tJ sl r 1 T (j) Da /05 rcoNTA;.: _ ";ON ACT PHON I s I4 667- rX g ONS BELOW: 1\— �TT-71-EC,T GBC- W- r HII�� A� fi0� ,.,-. Al IFLOOD ZZON bb r 44: _ YES LL . s g ix s IY C m PLOT FLAN L AN m T-1 SITE PLAN/PROJECT DESCRIPTION AA-1 FLOOR PLAN EXTERIOR ELEVATIONS SN -1 STRUCTURAL NOTES 5-1 FOUNDATION PLAN FRAMING/ROOF PLAN SD-1 STRUCTURAL DETAILS AR E C E I Ve D JUL 12 2005 Cl�t of Santa Ana SHEET INDEX .p im REVISIONS DATE SUBMITTAL 06I16/05 RESIBMI'TTA4 06/29/05 Led Door ARCHITECTURE Cindy C. Goff Architect Lie. C26946 4450 Hazelbrook Ave Long Beach, CA 90808 562.496.1627 V ul '+ J-u Mgt z 0� Ate— t �S �RL �A tu tu --F tu -J u z. i7 LU _ DATE- 06/2cJ/05 C SEE PLAN D WN TJ OBs 0305 H . T-1 I of 5 li WE5T ELEVATION NEW WEEP SCREED AND UNDER FLR VENT`G 1.1506.f. 5OUTT 4 ELEVATION aECT I ON A 12 NEW ROOF P#TCk TO MATC14 EXIST`G 4. F— NEW COMP ROOF TO MATCH EXIST'C% CLASS A, €3R SIMILAR. IC50 ES ER 5443 --- - EXISTING W -- NEW I EXISTING > ETCH EXIST'G STUCCO --- NEW — NEW, WEEP SCREED UNDER FLR VENTIG 1:150s.f. (a) STUCCO SCALE: 1/41' = 1'-011 SCALE: 1/4" = 11 "`0i1 SCALE; 1/4" m 1'-011 FLOOR EL AN N� **T' ' 50L 5 L E E 0 1. INSULATION $1 TALL 5E R13 IN ALL NEW WALLS AND RI9 IN ALL NEW CEILING& DEMO DECK 2. ALL SMOKE DETECTORS IN NEW CONSTRUCTION TO BE HARDWIRED W/BATTERY 5ACKUP. ELEC-TIR19AL5YM 5 EXISTING UJALL TO REMAIN IN THE CEILING OVERHEAD. 3. SMOKE DETECTORS IN EXISTING DWELLING MAY BE BATTERY OPERATED DUPLEX OUTLET 120V N W 2x�4 WALLS (u om.1 4. A 15AMP BRANCH CIRCUIT SHALL SUPPLY ONLY LIGHTING FIXTURES AND A 20AMP BRANCH - SINGLE POLE SWITCH CIRCUIT SHALL SE PERMITTED TO SUPPLY LIGHTIWs FIXTURES, RECEPTACLES, FIXED 3 WAY SWITCH (s) EX1ST'G APPLIANCES. 4 WALL HUNG LIGHT FIXTURE S. AFTER INSTALLING INSULATION, THE INSTALLER SHALL POST IN A CONSPICUOUS LOCATION 0 RECESSED LIGHT FIXTURE (n) NEW IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER AND THE BUILDER STATING THAT n SMOKE DETECTOR THE INSTALLATION CONFORMS WITH THE REQUIREMENTS OF TITLE 24, PART 6, AND THAT THE' MATERIALS INSTALLED CONFORMS WITH THE REQUIREMENTS OF TITLE 20, CHAPTER 2. PHONE JACK THE CERTIFICATE SHALL STATE THE MANUFACTURERS NAME AND MATERIAL IDENTIFICATION, TELEVISION/CABLE JACK THE INSTALLED R•VALUE AND THE :WEIGHT PER SQUARE FOOT. SUPPLY AIR ii�ELECTRICAL BOX 6. PROVIDE OUTLETS 0 EVERY 12' IN ADb1Tic?N. 0 JUNCTION BOX REVISIONS DATE SUBMITTAL 06/16/05 F'.ESUIB iITT 06/2S/05 ed Door ARCHMCTURE Cindy C. Goff Architect Lic. C26946 4450 Hazelbrook Ave Long Beach, CA 90808 562,496,1627 Q-. lu z c._ q z Adtk >-q lu }— _ t2k Cif CS) w ''i� Lu `y. lu !(Y V ul (V V X IL uj DATE, 06/29/05 SCALE: SEE FLAN D TJ OE3 03P.�5 SHEET A-1 2 of 5 Shute City t a 0 GENERAL. NOTES 1) All work shall comply with the requirements of the 2001 Califronia Building Codes and all amendments and local, county, state and federal regulations. 2) The contractor is responsible for coordination the work of all trades and shall check all dimensions and existing conditions prior to bid and signing of contract. All discrepancies shall be called to the attention of the engineer and be resolved in writing before proceeding with the work. 3) General notes and typical details shall apply to all parts of the job except where they are in conflict with details and notes on other documents; the more strict condition applies subject to review by the engineer. 4) All information shown on the plans relative to existing condition were carefully taken in the field but without guarantee of accuracy. Where actual conditions are in conflict with the plans, they shall be reported to the engineer so that proper changes can be made. 5) Required shop darwings shall be submitted to the engineer and the Building Department for review. 6) Modifications of structural paIns and material substitutions shall not be done without written approval of the engineer. 7) The approved plans and specifications represent the finish structure and do not include the methods of construction. The contractor shall supervise and direct the work and shall be solely responsible for construction methods, means, techniques, sequences and procedures including but not limited to shoring, insurance, fencing, construction canopy, scaffolding etc. Field observations by the engineer shall not be considered as inspections as required by the code. 8) Refer to the architectural plans for dimensions, openings, layout etc. �Jo. C040730 ��'Ic FJ Vz FOUNDATION 1 ) A soil report for the site is recommended. In lieu of a soil report, foundations have been dedsigned using minimum allowable soil bearing ca acity of 1,000 psi. Prior to placement of concrete, footings, a soils engineer shall inspect and certifyTe excavations to assure that design soil bearing values have been attained. 2) Foundation design is based on non -expansive soil. Soils engineer shall verify requried depth, width and reinforcement of footing if found that soil is expansive. The Contractor shall notify the structural design engineer in writing if soil is found to be expansive so that footings are redesigned prior to pouring of concrete foundations. 3) Compaction efforts shall attain a minimum 90% of Maximum Dry Density in accordance with A.S.T.M. 1556 and 1557. 4) Existing foundations are assumed to be in good condition. Contractor shall notify the eniineer of any foundation with sigificant differential settlement, severe cracking or any indication d structural failure or dis ress or defect, 5) The contractor shall be responsible for shoring, fence enclosures and protection life and property until the project is complete. 6) A diligent search shall be conducted by the soils engineer and rading or general contractor to locate cesspools, septic tank etc. if found, proper abandonmen? procedure shall be conduct as directed by �he soils engineer. Abandonment and/or compaction report shall be submitted to the City Building Department and engineer of record. 7) Existing footings supporting new additional loads shall be certified by the soils engineer to verify that bearing capactiy of existing soils is at least 1,000 psf. If existing soil bearing capacity is less than 1,000 psf, the structural design engineer shall be notified immediately in Writing so that proper adjustments can be made. REINFORCING STEEL 1) Reinforcing steel shall be deformed bars conforming to the requirements of A.S.T.M. A-615 grade 60 for bars larger than #4, gr. 40 for #4 or smaller. 2) Welded wire fabric shall conform toA,S.T.M. A-82 and A-185. Lap 12 inches minimum. 3) Detailing, fabrication and erection of reinforcing bars shall conform to the latest edition of A.C.I. Manual of Standard Practice for Detailing and Reinforced Concrete Structures. 4) Minimum cover for cast in place concrete shall be as follows: a) Poured against earth 3 inches b) Poured against form below grade 2 inches c) Formed slabs 3/4 inches d) Slab on grade, top cover 1 inch e) Column and Beam main bars 1-1/2 inches f) Walls exposed to weather #6 and larger 2 inches #5 and smaller 1-1/2 inches 5) Bars shall be clean of rust, grease and other deleterious material that may affect bond. 6) All bends shall be made cold. 7) Lap splice length shall be 40 bar diameters minimum and shall be staggered. 8) All reinforcing bars, embeds, anchor bolts, holdowns etc. shall be secured in place prior to placement of concrete. 9) Code required inspections by jurisdiction authority shall be made and signed off prior to placement of concrete. CONCRETE 1) The minimum compressive strength of concrete shall be fc= 2500psi @ 28 days unless otherwise noted. 2) aggregates shall conform to A,S.T.M. C33. 3) Ready -mixed concrete shall be in accordance with requirements of ASTM C94. 4) Maximum slump shall be 5" unless noted otherwise. 5) Concrete shall be maintained on the moist condition a minimum of 10 days after placement. 6) Prior to placing concrete, reinforcing steel and embedded items shall be well secured in proper positions. 7) Use type 11 or V cement as required against sulfate attack. STRUCTURAL AND MISCELLANEOUS STEEL 1 ) All structural and miscellaneous steel shall conform to A.S.T.M. A-36 and shall be fabricated and erected in accordance with the A.I.S.C, specifications for the Design, Fabrication and Erection of Structural Steel for building, latest edition. 2) Pipe columns shall conform to A.S.T.M. A-53 grade B. 3) Tubular steel shall conform to A.S.T.M. A500 grade B. 4) Bolts shall conform to A.S.T.M. A-307 unless noted otherwise. 5) Shop drawings shall be submitted to the architect and engineer and building department for review prior to fabrication. 6) fabrication shall be done in the shop of licensed fabricators. 7) Used electric arc process welding with E70XX electrodes. 8) All welding shall be done in the shop of licensed fabricator or provide continuous special inspection by a registered Deputy Inspector, 9) Where a fillet weld symbol is used in the plans without indication of size, the minimum weld size as specified in the A.I.S.C. Manual of Steel Construction shall be used. GLULAM/PARALLAM/MICROLAM BEAMS 1) Glue laminated beams shall be per UBC section 2312 and American Institute of Timber construction 117. Combination symbols shall be as follows: C) 24F-V4 DF/DF for simple beams b) 24F-V8 DF/DF for cantilevered beams 2) Parallam beams shall be 2.0E PSL 3) Microlam beams shall be 2.0E LVL 4) Laminp ,thted beams shall be fabricated by a licensed fabricator and shall be accompanied to the job site wit certificate of fabrication. 5) Shop drawings shall be submitted to the architect or engineer for review prior to fabrication. FRAMING LUMBER 1) All structural lumber shall be Douglas Fir Larch of the following minimum grades: a) 2x framing including plates and studs No. 2 b) 4x beams and headers up to 412 No. 2 c) larger than 4x1 2 and posts No. 1 d) 6x and larger beams No. I U.N.O. 2) Structural panels shall be Douglas fir conforming to U.S. Product Standard PS-1-95 CD with exterior glue, and shall bear the stamp of an approved fabricator. 3) Installation of vertical and horizontal sheathing shall first be approved by the inspector prior to covering. 4) No structural member shall be cut or notched unless specifically shown on approved plans. 5) Maximum moisture content of all lumber shall be 19W 6) bolt holes to be nominal diameter of bolt plus 1/16 inch unless noted otherwise. Provide washers under head and nuts of bolts and lag screws. 7) Framing connections shall be "Simpson Strong -Tie". 8) The number of nails connecting lumber shall not be less than the minimum required on UBC Table 23-I-Q. 9) All nails used on structural panels shall be common nails. 10) Built-up framing members shall be connected as follows: a) 2-2x 16d at 12" o.c. staggered top and bottom. b) 3-2x 5/8" dia. M.B. at 18" o.c. staggered top and bottom. c) 4-2x 5/8" dia. M.B. at 18" o.c. staggered top and bottom. 13) Provide double joists under parallel partitions. 14) Provide solid blocking under all non -parallel partitions. 15) Install lag bolts by drilling lead hole 65% to 75% of shank diameter and full diameter for shank portion. Use soap or other approved lubricant on threads. Installation shall be by tightening of screw not by hammering. 16) Truss Joists shop drawings shall be provided by the supplier and submitted to the Building Department for approval prior to fabrication, Shop drawings shall be stamped and wet signed by a licensed engineer. I in Z in r" 14 1-1 R C C U a U C u C U 0 U REVISION$ PATE SUIBMITTAL V6116101.1 REWSMITTAL 06/25/06 Qed Door ARCHITECTURE Cindy C. Goff Architect Lie. C26946 4450 Hazelbrook Ave Long Beach, CA 90808 562.496.1627 JU > z r\ > UJ Z Z3 SEE PLAN RAUN TJ J015 SPRIT 5N-1 3 of 5 Sh■ats lid speir-Al eg. 2x CONT, WI 2 - I6d EA, f3p( CALIF, FPANI'C 2x P.P. OF, 2x P/ P M55 T/ C -- LLI PN w ---- MIN, 40 F055 AT EA, FD— 5IMP, 55fG ENP OF 5NEAPWPU (PEP, NOLPPOWN5) (URO,) LLJ EXTENP PF, < 5EE SC Et7, �Eilow) 5IMP. WA C PAP PLAN) � 5N G TO WALL S U 2x 0P x PPE55UPE I Z� NAL'G i 11ATE17 511 PL PEP SHEAF WALL 2x GK'G --III 0 CONCPETE FTC, 2x 5TV W&. M5TAI! C� (CONTINUQU5) MYON2 OP 5TEM WALL 15-#� fe5 @ TOF' S" W CAL, IF. FRAM'G� Q � vv15T7 HOOK � t I �! V l� PPOVIPE A? I IONAE lA'1 t,"5TC328OP, 55TP24, Tt�4 55Ti6 1 Z lie 0 ii NEW 13EAM a) • 4- FEP PLAN SELECTION TABLE wi TOP PV OF, BEAM TO M 5-r e PCCEW 5TP.AAI' 51MP, 5fw, 5EE FLAN FOP 51ZE t ++ t++++ 7 + +-+++ �107 uj 5EI: PLAN W CODES: ICBO4935, CITY OF L.A, RR 25162 5�L P�'CY11Ir 11 FOP, P 1NI OP`CIWA X Ilk -IT EQUA EQU?L FOR CONCRETE FOUNDATION ONLY, 1J.! 5,eA6'l 'W Co Lk VA 1 0to r 0 22 17 POOP 5NEA11H'6 50LE PLATE NA,'G (5EE PLAN) Ll. POOF SHEA?�' 5IMP 5T22 p P PLAN 0 POOH` P.r+FTEP 0P SEE FLAN @EVEPY OTi-�P PA�FTEP E,N, OF FIIAFN, ` SHEAF WALL ,�OI5T (5EE FLAN) { U,O,N,) 5IMP ,A35 C, '15T, w1em OCCb1 A6, PEP A,i3, SCtiEb 2x FLP J015T t� 2x 6LK G - \ @ 12" O,C, < 5IMP, A35 @ 8" O,C, 2x POOP JOISTS U,O,N,/ 5,W, 5CfGULE SEE FLAN j -- E,N. Z CONT, POOfIN6 a? #4 W5CONT. w i E pc �, I FPOM TOP & KM V WL TOP PLATE '' I I I- _a l l a , ALT, LOCATION OF'`. , �� 1 I 2x 5TUP WALL s {� 51MP5, A5SF OP LTP4 @ 8" O C, C SEE PLAN) h _ I' I ' } t�1 U.O,N.I5CW 1121E i1�i i11 #r,i� ; # SHEAP'NFV.L @ 2x PIPE LXP19 OP NAT, av E17 IEP 5112E FL115H 0122 rCAM SEE PLfW L!J m 23 H C? 18 10 6 2 1 2x LI J5T C3 2x ;31.K'G Z COL/t t. Bat./PAD d W SFF x PLAN fl! D 4x 6IF, \ > 5IMP, LL1 j ° W I Q 51tvIP� P.U, I.... # .z Z P3 AM (5EE PLAN) ` t� 7" _ ¢ 5IMP, ECOPC OP ECCQ FOP ENP CONCH, 4 �'% U5E CC CC6, FOP oRAoE am., SIZE t REINF. \, 0 PER PLC! `' CL P05T (5T PLAN,) PAp FOOT'G (� c� ° FEP PLAN W a TIES INVi �P PC IZ: NON —SHRINK 5EE PLAN LL GRIJILIT V� 0. I3M @ C, J5T, Wm OCCUP 0 CL M3UI 4 19 u _I`\� SEE PLAN E5OF CL 8 STL COIL, W% E PLATE 5IMP, M5T48 (U,O,N,> { 2 v LL! - ►" , w, NOOP OX — EXW5T'G N> w ------ 4 X w t�tp. SM. + � ; � � . =CONT, PEINF, .._._.I'.F. 0.00' ;�E PLAN PEP Pf AN � GR. Sm. REiNF PER PLAN MODEL NO, STEMWALL WIDTH MIN SSTB16 6 JDIAILENGTHEeBE 17 12 SSTS20 6 21 16 SSTB24 6 25 20 SSTB28 6 29 24 SSTB34 6 34 28 SST836 6 z 36 28 CODES: BOCA, ICBO, SBCCI NER-393 NER-469; CITY OF L.A. RR 24818, RR25158 AND RR 25293 MODEL •x. 3x, 2-2x SILL PLATES MONO POU4 TWPOUR NO. HD2A LTT20B SST816 SSTS20 LTT131 HTT16 PHDS HD5A SSTB20 SSTB24 NTT28B HTT22 SST 24 PH06 PHOB HD6A SSTB28 SSTB34 HDBA HD10A ca 12H CL 3° CLR. 3 TIES 0 W O.C. . TIES 6 Z D.C. t,: LK L- i O 0 Q VfJMV ? lU MFl1c'm CONT PAP5 IN NEW FOOT' G( EPDXY 6' INTO EXIST' Foof,6) OPCWOVW/'FOPPOK' NO 5PECIAL INSPECTION CL uj uj . ... ... , . REVISIONS DATE SUBMITTAL 6/I6/05 FE~SUBMITfi /2S/05 ed Door ARCHITECTURE Cindy C. Goff Architect Lic, C26946 4450 Hazelbrook Ave Long Beach, CA 90808 562.496.1627 ZO .. c\ qZ l.t_t i-- u 1__.t DATE: 0+6/29/05 SGALE< SttEE PLAN M�x Tj JOB 03fa5 SWEET 6DI of 5 SHOELe ■