HomeMy WebLinkAbout220 S Daisy Ave & Unit MET01 - PlanE X X X X W WW W W W W W W E E E E E E E E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E 3 SS ECGR E E E E SS SS PI RD IR IR E E E EE E IR GT GT GT GT GT GT E 30'-3" (TYP) 8' ( T Y P ) 9' ( T Y P ) 30' 30' 30' 6' 8' 4' - 5 " 2' 3' - 1 " 2' - 6 " 3' 2'-10" 2'-8" C2 CIVIL SITE PLAN SCE ID:00002141204 CITY OF SANTA ANA CORPORATE YARD 220 S DAISY AVE SANTA ANA, CA 92703 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S8 GG MW 05/01/26 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 12/04/2550% CONSTRUCTION DOCUMENTS 02/17/26100% CONSTRUCTION DOCUMENTS 05/01/26100% CONSTRUCTION DOCUMENTS REV1 1.FOR ELECTRICAL INFORMATION, SEE SHEET E1 1.CONTRACTOR SHALL LEGALLY DISPOSE OF ALL DEMOLISHED MATERIALS OFF SITE. 2.CONTRACTOR SHALL PROTECT ALL EXISTING UTILITY IMPROVEMENTS NOT SPECIFICALLY DESIGNATED FOR REMOVAL. 3.THE ON-SITE UNDERGROUND UTILITIES SHOWN ON THIS SHEET ARE AT AN APPROXIMATE LOCATION. THE EXTENT, LOCATIONS AND SIZES ARE UNKNOWN. THE CONTRACTOR SHALL POTHOLE TO LOCATE AND VERIFY THE UNDERGROUND UTILITY LINES PRIOR TO REMOVAL. 4.CONTRACTOR TO PROTECT AND PRESERVE IN PLACE ANY FOUND SURVEY MONUMENTS. ANY MONUMENTS DISTURBED SHALL BE RESET BY A LICENSED SURVEYOR AND THE APPROPRIATE PAPERWORK FILLED WITH THE CITY OR COUNTY. 5.ALL HAZARDOUS MATERIALS ENCOUNTERED DURING SITE DEMOLITION SHALL BE REMEDIATED AND DISPOSED OF PER STATE AND EPA REQUIREMENTS. 6.CONTRACTOR SHALL CONTACT AND COORDINATE WITH ALL UTILITY AGENCIES PRIOR TO THE START OF ANY DEMOLITION OR CONSTRUCTION. 7.ANY EXISTING UTILITIES AND/ OR IMPROVEMENTS THAT BECOME DAMAGED DURING CONSTRUCTION SHALL BE COMPLETELY RESTORED TO THE SATISFACTION OF THE OWNER AND AGENCY HAVING JURISDICTION, AT THE CONTRACTOR'S SOLE EXPENSE. GENERAL NOTES DEMOLITION NOTES LEGEND EXISTING EDGE OF PAVEMENT LINE EXISTING NATURAL GAS GEOPHYSICAL LINE EXISTING WATER LINE LIMITS OF WORK W W G G CONSTRUCTION NOTES EXISTING SANITARY LINE SS SS BL DD E E E E G GT D C D S C S W W W EXISTING BOLLARD EXISTING DOWN DRAIN EXISTING DROP INLET EXISTING ELECTRICAL BOX EXISTING ELECTRICAL PARKING STATION EXISTING ELECTRICAL RISER EXISTING ELECTRICAL TRANSFORMER EXISTING ELECTRICAL VAULT EXISTING ELECTRICAL LIGHT EXISTING NATURAL GAS METER EXISTING GATE EXISTING STORM DRAIN CLEANOUT EXISTING STORM DRAIN MANHOLE EXISTING SEWER CLEANOUT EXISTING SEWER MANHOLE EXISTING HANDICAP PARKING EXISTING SIGN EXISTING WATER MARKING POST EXISTING WATER RISER EXISTING WATER VALVE EXISTING WHEEL STOP EXISTING ELECTRICAL LINE E E EXISTING FENCE LINE 1 2 3 4 INDICATE EVSE CHARGEPORT STALL PROPOSED SERVICE 600A 480/277V METERED SWITCHBOARD PROPOSED 300KVA STEP DOWN XFMR PROPOSED 1000A 208V SERVICE DISTRIBUTION E PROPOSED WHEELSTOP PROPOSED BOLLARD PROPOSED ELECTRICAL LINE PROPOSED L2 DUAL PORT WALL MOUNTED EV CHARGER EXISTING 500KVA 480/277V 3Ø TRANSFORMER PROPOSED TRENCH AND PAVEMENT RESURFACING PER DETAIL 1, SHEET C3 PROPOSED CONCRETE EQUIPMENT PAD, PER DETAIL 2, SHEET C3 PROPOSED WHEELSTOP, PER DETAIL 3, SHEET C3 PROPOSED DUAL PORT L2 CHARGER TO BE MOUNTED TO WALL/COLUMN PROPOSED UTILITY TRANSFORMER EXISTING BUILDING EXISTING PARCEL LINE (TYP) EXISTING WALL (TYP) (TYP) 1 2 4 4 4 4 4 4 4 4 4 4 (TYP) 3 PROPOSED CONDUIT TO BE INSTALLED ON WALL (TYP) 3 EXISTING WHEEL STOP (TYP) CORE THOUGH CMU WALL. EXISTING WHEEL STOP TO BE REMOVED/RELOCATED (TYP) EXISTING COLUMNS (TYP) 0 2010105 SCALE: 1" = 10' 1 1 26 SIGNED: 05/01/2026 C3 CIVIL DETAILS SCE ID:00002141204 CITY OF SANTA ANA CORPORATE YARD 220 S DAISY AVE SANTA ANA, CA 92703 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S8 GG MW 02/17/26 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 12/04/2550% CONSTRUCTION DOCUMENTS 02/17/26100% CONSTRUCTION DOCUMENTS 24 " M I N . T O T H E T O P OF H I G H E S T C O N D U I T 95% COMPACTED NATIVE BACKFILL NOTE: 1.ALL PATCHES TO PEDESTRIAN SURFACES SHALL COMPLY WITH 11B-302.1 AND 11B-303, TYP. 18" 36" 2" 3" 2"3" YELLOW PLASTIC WARNING TAPE TO BE REQUIRED ABOVE AND ALONG ENTIRE LENGTH OF DUCT BANK. SEE ELECTRICAL PLANS FOR CONDUIT SIZE, TYPE, AND WIRING REPLACE TOP SURFACE IN KIND, RECOMPACT SOIL TO 90% 12 " NO SCALETRENCH AND PAVEMENT RESURFACING 1 3" (TYP) FINISHED GRADE 3/4" CHAMFER (TYP) #5 @ 12" O.C. BOTH WAYS CENTERED IN SLAB 8" 4" M I N 15'-0" x 4'-0" 12 " 95% MINIMUM RELATIVE COMPACTED NATIVE BACKFILL PER ASTM D1557. OVER EXCAVATE 12" AND RECOMPACT 95% CONCRETE NOTE: 1.INSTALL ANCHORAGE TO SECURE EQUIPMENT PER E1 AND TYPICAL EQUIPMENT ANCHORAGE DETAIL. 2.MAXIMUM ENCLOSURE WEIGHT=2.000 LB. ENCLOSURE WEIGHT INCLUDES SWITCHBOARD, TRANSFORMER, AND DISTRIBUTION BOARD WEIGHTS. 3" C L R CONCRETE PAD DETAIL NO SCALE 2 NO SCALETYPICAL EQUIPMENT ANCHORAGE DETAIL 4 SWITCHGEAR - EACH MODULE 6" MIN EDGE DISTANCE (TYP) 6" MIN EDGE DISTANCE (TYP) EQUIPMENT BASE 1/2" DIAMETER SS 304/316 HILTI KWIK BOLT TZ EXPANSION ANCHOR WITH MINIMUM NOMINAL EMBEDMENT OF 2 1/2" REFER TO MANUFACTURER DWGS FOR ANCHOR ARRANGEMENT AND QUANTITY. CONCRETE SLAB TRANSFORMER EQUIPMENT BASE 1/2" DIAMETER SS 304/316 HILTI KWIK BOLT TZ EXPANSION ANCHOR WITH MINIMUM NOMINAL EMBEDMENT OF 2 1/2" CONCRETE SLAB NO SCALECONCRETE WHEEL STOP 3 SE E N O T E 1 *CONCRETE TO TEST AT 3000 PSI AT 28 DAYS FILL HOLE WITH NON-SHRINK GROUT PRECAST CONC WHEEL STOP #3 BARS PROPOSED AC PVMT 1" 1" #6 x 30" BAR AT EACH END 6" 2.5" 2" 6" 72" 26 SIGNED: 02/17/2026 T1 TITLE SHEET SCE ID:00002141204 CITY OF SANTA ANA CORPORATE YARD 220 S DAISY AVE SANTA ANA, CA 92703 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S8 GG MW 02/17/26 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 12/04/2550% CONSTRUCTION DOCUMENTS 02/17/26100% CONSTRUCTION DOCUMENTS GENERAL GRADING AND DRAINAGE NOTES: THE REQUIREMENTS AND INFORMATION SET OUT BELOW ARE PROVIDED FOR THE CONTRACTOR'S CONVENIENCE AND DO NOT ENCOMPASS ALL PROJECT REQUIREMENTS DESCRIBED BY THE PROJECT PLANS AND SPECIFICATIONS AND/OR APPLICABLE LAWS, REGULATIONS AND/OR BUILDING CODES 1.CONSTRUCTION OF ALL PROJECT SITE IMPROVEMENTS SUBJECT TO ADA ACCESS COMPLIANCE, INCLUDING ACCESSIBLE PATH OF TRAVEL, CURB RETURNS, PARKING STALL(S) AND UNLOADING AREAS, BARRIER FREE AMENITIES AND/OR OTHER APPLICABLE SITE IMPROVEMENTS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT, CALIFORNIA TITLE 24, AND THE CALIFORNIA BUILDING CODE, CURRENT EDITION(S). 2.CONTRACTOR SHALL FIELD VERIFY ALL GRADE AND SLOPES PRIOR TO THE PLACEMENT OF CONCRETE AND/OR PAVEMENT FOR CONFORMANCE WITH ADA ACCESS COMPLIANCE REQUIREMENTS. EXAMPLES OF MINIMUM AND MAXIMUM LIMITS RELATED TO ADA ACCESS COMPLIANCE INCLUDE, BUT ARE NOT LIMITED TO: A) ACCESSIBLE PATH OF TRAVEL CROSS-SLOPE SHALL NOT EXCEED 2% B) ACCESSIBLE PATH OF TRAVEL LONGITUDINAL SLOPES SHALL NOT EXCEED 5% C) RAMP LONGITUDINAL SLOPES SHALL NOT EXCEED 8.33% WALKS SHALL NOT HAVE LESS THAN 48 INCHES IN UNOBSTRUCTED WIDTH. 3.CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IDENTIFIED BY THE PROFESSIONAL ENGINEERING SEAL AND SIGNATURE ON THESE PLANS, OF ANY SITE CONDITIONS(S) AND/OR DESIGN INFORMATION THAT PREVENTS THE CONTRACTOR FROM COMPLYING WITH THE LAWS, REGULATIONS AND/OR BUILDING CODES GOVERNING ADA ACCESS COMPLIANCE. 4.GROUND SLOPES AWAY FROM BUILDING PADS IN LANDSCAPED OR DIRT AREAS SHALL BE NO LESS THAN 5.0% FOR AT LEAST TEN (10) FEET, OR AS OTHERWISE NOTED ON THE PLANS. 5.DRAINAGE SHALL NOT BE ALLOWED ONTO ADJACENT PROPERTY. 6.ALL FILL MATERIAL USED TO SUPPORT THE FOUNDATIONS OF ANY BUILDING OR STRUCTURE SHALL BE PLACED UNDER THE DIRECTION OF A LICENSED GEOTECHNICAL ENGINEER, AND IN COMPLIANCE WITH THE PROJECT SPECIFICATIONS. A SOILS COMPACTION REPORT SHALL BE SUBMITTED TO THE ENGINEER OF RECORD AS REQUIRED BY THE PROJECT SPECIFICATIONS. 7.THE CONTRACTOR SHALL IMPLEMENT DUST CONTROL MEASURES AS REQUIRED BY THE PROJECT SPECIFICATIONS, AND BY GOVERNING PUBLIC AGENCIES. 8.CONTRACTOR TO MATCH EXISTING PAVEMENT GRADE AT ALL NEW PAVEMENT LOCATIONS UNLESS OTHERWISE NOTED ON THE PLANS. 1.CONTRACTOR SHALL PROVIDE ALL MATERIALS SUCH AS TOOLS, EQUIPMENT, LABOR, AND INCIDENTALS REQUIRED INCLUDING THE CONSTRUCTION OF ALL PROPOSED IMPROVEMENTS SHOWN ON THE PLANS AND AS SPECIFIED BY THE GOVERNING STANDARDS AND/OR THE CIVIL AND ELECTRICAL ENGINEERS. 2.CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION OF THE PROPOSED IMPROVEMENTS. 3.IF DAMAGED DURING CONSTRICTION, THE CONTRACTOR SHALL REPLACE IN KIND ALL EXISTING STRUCTURES, WALKWAYS, CURB & GUTTER, LANDSCAPING, AND/OR OTHER IMPROVEMENTS TO AN EXISTING OR BETTER CONDITION. 4.CONTRACTOR SHALL REPLACE ALL EXISTING STRIPING, SIGNAGE AND MARKINGS DAMAGED IN KIND DUE TO PROJECT CONSTRUCTION ACTIVITIES. 5.ALL WORK SHALL BE CONFINED WITHIN THE EASEMENTS AND/OR CONSTRUCTION LIMITS AS SHOWN ON THE PLANS. 6.APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK TO BE PERFORMED UNTIL A PERMIT OR NOTICE TO PROCEED HAS BEEN ISSUED 7.BEFORE COMMENCING WORK, THE CONTRACTOR SHALL NOTIFY ALL UTILITY AUTHORITIES OR UTILITY COMPANIES HAVING POSSIBLE INTEREST IN THE WORK OF THE CONTRACTOR'S INTENTION TO EXCAVATE PROXIMATE TO EXISTING FACILITIES AND THE CONTRACTOR SHALL VERIFY THE LOCATION OF ANY UTILITIES IN THE WORK AREA. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (U.S.A.) TWO (2) DAYS PRIOR TO BEGINNING ANY EXCAVATION. 8.THE CONTRACTOR SHALL OBTAIN WRITTEN AUTHORIZATION FROM ANY PROPERTY OWNER GIVING PERMISSION TO ENTER THE PROPERTY FOR THE PURPOSE OF CONSTRUCTING THE IMPROVEMENTS DELINEATED ON THE PLANS AND TRANSITION THERETO. 9.ALL BILL OF MATERIALS AND/OR EQUIPMENT SHALL BE PROVIDED AS SPECIFIED WITHIN THIS SET OR APPROVED EQUAL. ALL BULL OF MATERIALS AND/OR EQUIPMENT SHALL MATCH THE SAME QUALITY AND CAPACITY AS INDICATED HEREIN GENERAL CONTRACT NOTES: 1.LOCATIONS OF ALL UNDERGROUND FACILITIES ARE TAKEN FROM AVAILABLE MAPS AND RECORDS. ACTUAL FIELD LOCATIONS OF ALL UTILITIES MUST BE VERIFIED BY CONTRACTOR PRIOR TO TRENCHING. CONTACT USA DIGALERT, 1-800-227-2600, PRIOR TO DIGGING. 2.CONTRACTOR TO HAND-DIG ANY AND ALL LOCATIONS WHERE UNDERGROUND UTILITIES ARE SUSPECTED OR KNOWN. SURVEY NOTE: UTILITY NOTE: UTILITY INFORMATION SHOWN HEREON IS BASED ON RECORD INFORMATION SUPPLIED TO THE ENGINEER BY UTILITY COMPANIES, PUBLIC AGENCIES AND THE PROPERTY OWNER, TOGETHER WITH EVIDENCE GATHERED FROM SURFACE LOCATING METHODS AND OBSERVATION OF VISIBLE EVIDENCE BY A FIELD SURVEY. THE ENGINEER CAN MAKE NO GUARANTEE AS TO THE ACCURACY OR COMPLETENESS OF THE UNDERGROUND UTILITY FACILITIES SHOWN. PRIOR TO ANY SITE EXCAVATIONS, THE CONTRACTOR SHALL CONTACT THE OWNER AND UNDERGROUND SERVICE ALERT (U.S.A.) AND REQUEST THE THEY IDENTIFY THE LOCATION OF ALL UNDERGROUND UTILITIES AT THE SITE. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. FLOOD ZONE NOTES: DIGALERT NOTES CONCRETE NOTES: 1.CONCRETE COMPRESSIVE STRENGTH: ALL CONCRETE SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH AS SHOWN IN THE TABLE 1 BELOW AT 28 DAYS, U.N.O. ON PLANS. SEE ALSO SULFATE CONTENT NOTES. 2.AGGREGATES IN CONCRETE: SHALL BE NATURAL SAND AND ROCK (150 LB/CU. FT) CONFORMING TO ASTM C33. AGGREGATE SHALL HAVE PROVEN SHRINKAGE CHARACTERISTICS OF LESS THAN 0.04% PER ASTM C157. DO NOT CHANGE SOURCE OF AGGREGATE DURING COURSE OF WORK WITHOUT WRITTEN CONSENT OF ENGINEER. 3.CEMENT: SHALL BE PORTLAND CEMENT CONFORMING TO ASTM C150. CEMENT SHALL BE TYPE II OR AS REQUIRED TO SATISFY SITE SOIL CONDITIONS. REFER TO TABLE 1 FOR MAXIMUM WATER TO CEMENT RATIO. MINIMUM OF (6) SACKS OF CEMENT FOR EACH CUBIC YARD OF CONCRETE. *SLUMP SHALL BE MEASURED PRIOR TO THE ADDITION OF SUPERPLASTICIZER (IF USED.) REBAR CLEAR COVER CONCRETE: THE FOLLOWING MINIMUM CLEAR DISTANCES BETWEEN REINFORCING STEEL AND FACE OF CONCRETE SHALL BE MAINTAINED UNLESS NOTED OTHERWISE: 4.VIBRATION: VIBRATION OF CONCRETE SHALL BE IN ACCORDANCE WITH GENERAL PROVISIONS OUTLINES IN PORTLAND CEMENT ASSOCIATION SPECIFICATION ST26 5.CURING: CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF FIVE DAYS AFTER PLACEMENT. FOR CONCRETE OTHER THAN SLAB ON GRADE, APPROVE CURING COMPOUNDS MAY BE USED IN LIEU OF MOIST CURING ONLY IF APPROVED BY THE ENGINEER. 6.INSPECTIONS, TESTING & QUALITY ASSURANCE: A MINIMUM OF ONE COMPRESSION TEST AT 7 DAYS AND 2 TESTS AT 28 DAYS FOR ALL CONCRETE SAMPLE. TAKE TEST AT A FREQUENCY OF ONCE EVERY 150 CU. YDS OR 5,000 SQ. FT MINIMUM. 7.ANCHOR BOLTS, DOWELS, INSERTS: SHALL BE TIED IN PLACE PRIOR TO POURING CONCRETE. 8.CONSTRUCTION AND POUR JOINTS:LOCATIONS SHALL BE APPROVED BY ENGINEER PRIOR TO POURING CONCRETE. 9.FORMWORK:FORMWORK TOLERANCE SHALL BE IN ACCORDANCE WITH THE C.B.C. AND A.C.I. STANDARDS. 10.PIPES IN CONCRETE: PIPES MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES BUT SHALL NOT BE EMBEDDED THEREIN. PIPES OR DUCTS EXCEEDING ONE-THIRD THE SLAB OR WALL THICKNESS SHALL NOT BE PLACED IN THE STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED. 11.EXPOSED CORNERS: PROVIDE 3/4" CHAMFERS AT ALL EXPOSED CORNERS. 12.DRYPACK OR GROUT: CONCRETE STRENGTH SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI AND BE COMPOSED OF ONE PART PORTLAND CEMENT TO NOT MORE THAN THREE PARTS SAND. 13.FLY ASH: NOT PERMITTED. CONCRETE STRENGTH CONDITION MIN 28-DAY COMPRESSIVE STRENGTH, F'C CONCRETE TYPE* MAXIMUM AGGREGATE SIZE WATER TO CEMENT RATIO MAX SLUMP** SLAB ON GRADE/ CONC PADS 3,000 PSI NWC REBAR CLEAR OVER FOR CAST-IN-PLACE CONCRETE CONDITION COVER CONCRETE CAST AGAINST EARTH 3" MIN OTHERWISE 2" MIN SOIL NOTE: 1.ALLOWABLE BEARING PRESSURE IS ASSUMED 1,500PSF. BASIS OF BEARINGS: 1.ALL WORK SHALL CONFORM TO 2022 TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR). 2.CHANGES TO THE APPROVED DRAWINGS AND SPECIFICATIONS SHALL BE MADE BY AN ADDENDUM OR A CONSTRUCTION CHANGE DOCUMENT (CCR) APPROVED BY THE DIVISION OF THE STATE ARCHITECT, AS REQUIRED BY SECTION 4-338, PART 1, TITLE 24, CCR. 3.GRADING PLANES, DRAINAGE IMPROVEMENTS, ROAD AND ACCESS REQUIREMENTS AND ENVIRONMENTAL HEALTH CONSIDERATIONS SHALL COMPLY WITH ALL LOCAL ORDINANCES. 4.FIRE SAFETY DURING DEMOLITION AND CONSTRUCTION SHALL COMPLY WITH CBC CHARTER 33 AND CFC CHAPTER 33. DSA NOTES 1.THE UNDERGROUND UTILITIES SHOWN HEREON HAVE BEEN LOCATED FROM UTILITY MARK OUTS PROVIDED BY CONAWAY GEOMATICS ON NOVEMBER 7, 2025. THE CERTIFYING SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE CERTIFYING SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH THEY DO CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. THE CERTIFYING SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 2.ELEVATIONS SHOWN HEREON WERE DERIVED FROM GPS OBSERVATIONS, WITH RELATIVE ACCURACY OF ±0.1. THE BASIS OF BEARINGS FOR THIS MAP IS THE INTERNATIONAL TERRESTRIAL REFERENCE FRAME 2020 (ITRF2020), DERIVED FROM THE TRIMBLE RTX (REAL TIME EXTENDED) SOLUTION, ADJUSTED TO THE 2025.85 EPOCH, NAD 83, ZONE 6. COORDINATES SHOWN HEREON ARE GRID VALUES. USE THE FOLLOWING LOCAL SITE VALUES TO OBTAIN GROUND VALUES: ·LOCAL SITE -LAT: 33°44'36.488452"N LON: 117°53'43.103803"W E HGT: -38.62 FT GSF:1.0000185431 ELEVATIONS SHOWN HEREON ARE EXPRESSED IN US SURVEY FEET, BASED ON THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88), AND ARE DERIVED FROM GPS OBSERVATIONS PER THE ADJUSTMENT SHOWN ABOVE. 1.PROJECTED SITE LOCATION WITHIN FLOOD HAZARD ZONE X SHADED; AREA OF REDUCED FLOOD RISK DUE TO LEVEE. 2.FIRM PANEL: 06059C0257J 3.MAP EFFECTIVE DATE; DECEMBER 3, 2009 26 SIGNED: 02/17/2026 TITLE SHEET T1 SCE ID:00002141204 CITY OF SANTA ANA CORPORATE YARD 220 S DAISY AVE SANTA ANA, CA 92703 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S8 GG MW 02/17/26 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 12/04/2550% CONSTRUCTION DOCUMENTS 02/17/26100% CONSTRUCTION DOCUMENTS CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON SCE ID-00002041204 | CITY OF SANTA ANA CORPORATE YARD 220 S DAISY AVE, SANTA ANA, CA 92703 SITE MAP VICINITY MAP PROJECT INFORMATION:OWNER/REPRESENTATIVE INFORMATION LIST OF CONSULTANTS UNDERGROUND SERVICE ALERT UTILITY NOTIFICATION CENTER OF SOUTHERN CALIFORNIA 811 OR (800) 422-4133 3 WORKING DAYS UTILITY NOTIFICATION PRIOR TO CONSTRUCTION CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING LOCATIONS, CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME ELECTRICAL: CAMERON CEDERLIND, PE NV5, INC 15092 AVENUE OF SCIENCE, #200 SAN DIEGO, CA 92128 858-385-0500 TITLE SHEET T1, T2 OVERALL SITE PLAN C1 CIVIL SITE PLAN C2 CIVIL DETAILS C3, ELECTRICAL SITE LAYOUT E1 SINGLE LINE DIAGRAM E2 ELECTRICAL LOAD SCHEDULE TABLE E3 ELECTRICAL DETAILS E4, E5 CIVIL AND STRUCTURAL: NAT LLOYD NV5, INC 15092 AVENUE OF SCIENCE, #200 SAN DIEGO, CA 92128 559-676-7988 TRANSPORTATION ELECTRIFICATION PROJECT MANAGER: CHRIS KANOWSKY PROJECT MANAGER 6090 N IRWINDALE AVE SUITE B IRWINDALE, CA, 91702 310-803-4956 EV CHARGING PORTS QTY L2 PUBLIC 0 0 FLEET 20 20 TOTAL 20 20 AREA OF WORK 2025 CALIFORNIA BUILDING CODE (CBC) 2025 CALIFORNIA ELECTRICAL CODE (CEC) NATIONAL ELECTRICAL CODE (NEC) 2023 LOCATION: 1001 COUGAR WAY, BEAUMONT, CA 92223 1.TOTAL LOT SIZE: 37.46 ACRES 2.APN 404-230-003 DESIGN CRITERIA: UNDERGROUND SERVICE ALERT INDEX SHEET: SCOPE OF WORK BEAUMONT UNIFIED SCHOOL DISTRICT KEN MUELLER KEMUELLER@BEAUMONTUSD.K12.CA.US 951-797-5398 1.INSTALLATION OF LOAD-SIDE INFRASTRUCTURE FOR THE CHARGE READY PROGRAM 2.INFRASTRUCTURE TO SUPPORT 20 WALL MOUNTED EVCS. 3.(1) NEW 150KVA 480/277V TRANSFORMER BY SCE. 4.INSTALL (1) NEW 400A, 480V, 3Ø, 4W METERED SWITCHBOARD. 5.INSTALL (1) NEW 225KVA 480/208V STEP DOWN TRANSFORMER. 6.INSTALL (1) NEW 600A 208/120V DISTRIBUTION SWITCHBOARD. 7.INSTALL (10) NEW DUAL WALL MOUNTED TERMINAL BLOCKS. 8.INSTALL PROTECTIVE EQUIPMENT FOR PROPOSED CHARGER INFRASTRUCTURE AND SUPPORTING EQUIPMENT. 9.CHARGERS ARE NOT IN THIS SCOPE OF WORK AND ARE FOR REFERENCE ONLY. SITE LOCATION 26 SIGNED: 02/17/2026 TKJ Structural Engineering 9820 Willow Creek Rd., Suite 490 San Diego, CA 92131 858.649.1700 www.tkjse.com STRUCTURAL CALCULATIONS For: Charge Ready Program at City of Santa Ana Corp Yard 220 S Daisy Ave Santa Ana, CA 92703 Date: TKJSE Job #: May 1, 2026 26035 1 of 32 6-30-27 S 4845 EXP. STRUCTURAL TIMOTHY KYL E JAQUESS STATE OF CALIFORNIA REG ISTERED PROFESSIONAL ENGINEE R TKJ Structural Engineering 9820 Willow Creek Rd., Suite 490 San Diego, CA 92131 858.649.1700 www.tkjse.com SCOPE AND TABLE OF CONTENTS Project Description: Project: Address: Client: Scope: Table of Contents: Section Basis of Design 3 to 3 ASCE 7 Hazards Report 4 to 8 Equipment Anchorage Design Approach 9 to 10 Switchboard A 11 to 15 Forces 14 to 14 Pad 15 to 15 Switchboard B 16 to 20 Forces 19 to 19 Pad 20 to 20 Transformer 21 to 24 Forces 23 to 23 Pad 24 to 24 Anchor Design 25 to 32 The calculations provided herein are the property of TKJ Structural Engineering, Inc., and may be used solely by the Client for the Project located at the Address noted above. The project involves support and anchorage of the newelectrical equipment shown on the contract drawings. Calculations are provided for the support and anchorage of this equipment. Pages City of Santa Ana Corp Yard 220 S Daisy Ave Santa Ana, CA 92703 NV5 2 of 32 Project: Project No.: Date: BASIS OF DESIGN •2025 California Building Code •ASCE 7-22 Minimum design loads for buildings and other structures •2019 ACI 318-19 Building Code Requirements for Structural Concrete Material Specifications & Strengths •Concrete* 3,000 psi specified, design for 2,500 psi •Reinforcing Steel Fy = 60 ksi Allowable Soil Pressures Max Bearing Pressure: Lateral Soil Pressure: Seismic Design Data: ASCE 7-22 Wind Design Data: ASCE 7-22 Risk Category II Basic Wind Speed V=mph Seismic Importance Factor Ie=Exposure Category Mapped Acceleration SS=g Gust Factor G = Mapped Acceleration S1=g Velocity Pressure Coefficient Kz= Design Spectral Acceleration SDS=g Directionality Factor Kd= Design Spectral Acceleration SD1=g Topographic Factor Kzt= Site Class DEFAULT Seismic Design Category D Analysis Procedure Nonstructural Components Components Switchboard Transformer 2.0 2.001.0 1.4 City of Santa Ana Corp Yard 1.170 0.85 5/1/2026 26035 1.00 *Concrete is exempt from special inspections per CBC 2025 1705.3 Exceptions 1. TKJSE is voluntarily specifying Mix Design on plan to ensure a qualified inspector reviews and verifies compliance with the specifications prior to concrete placement to maintain quality assurance. 0.820 1.00 1500 psf** 1/3 increase permitted for load cases including short-term loads 95 1.49 0.56 0.85 100 psf* 2.00 C 0.85 1.0 1.4 1.5 Ip CAR Rpo Ωop 3 of 32 ASCE Hazards Report Address: 220 S Daisy Ave Santa Ana, California 92703 Standard:ASCE/SEI 7-22 Latitude:33.74378 Risk Category:II Longitude:-117.8955 Soil Class:Default Elevation:78.87017635258572 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph 300-year MRI 89 Vmph 700-year MRI 95 Vmph 1,700-year MRI 101 Vmph 3,000-year MRI 106 Vmph 10,000-year MRI 115 Vmph 100,000-year MRI 133 Vmph 1,000,000-year MRI 151 Vmph Data Source: ASCE/SEI 7-22, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Fri May 01 2026 Page 1 of 5https://ascehazardtool.org/Fri May 01 2026 4 of 32 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-22 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Values for 10-year MRI, 25-year MRI, 50-year MRI and 100-year MRI are Service Level wind speeds, all other wind speeds are Ultimate wind speeds. Site is not in a hurricane-prone region as defined in ASCE/SEI 7-22 Section 26.2. Page 2 of 5https://ascehazardtool.org/Fri May 01 2026 5 of 32 PGA M : 0.67 SMS : 1.75 SM1 : 1.23 SDS : 1.17 SD1 : 0.82 T L : 8 SS : 1.49 S1 : 0.56 VS30 : 260 Seismic Design Category:D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE SpectrumR S (g) vs T(s)a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic DefaultSite Soil Class: Results: Page 3 of 5https://ascehazardtool.org/Fri May 01 2026 6 of 32 Data Accessed: Fri May 01 2026 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-22 and ASCE/SEI 7-22 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-22 Ch. 21 are available from USGS. Page 4 of 5https://ascehazardtool.org/Fri May 01 2026 7 of 32 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 5 of 5https://ascehazardtool.org/Fri May 01 2026 8 of 32 9 of 32 10 of 32 Project: Project #: Prepared By: Date: 11 of 32 CITY OF SANTA ANA CORP YARD CR 690 26035 AUSTIN SPINELLI SWITCHBOARD A Enclosure Specification Additional Information Shipping may loosen electrical connections. Check tightness before energizing. Bonded neutral - Remove neutral load conductors for test purposes only! Field-installed conductors shall be 60º C, 70º C, or 90º C, sized to 60º C rating for 110 amps or less; and 75º C or 90º C for 125 amps and above. D E T A I L S CP3F-F ENCLOSURE - 56"W x 64"H x 27"D TYPE 3R ENCLOSURE ALUMINUM ENCLOSURE MATERIAL PAINTED GRAY 480Y/277V 3PH 4 WIRE SCCR 50kA UTILITY - Southern California Edison SCE Charge Ready Program CATALOG SPECIFIC NAMEPLATE LABEL OF ESTIMATED WEIGHT INSIDE DIST DOOR MILBANK K6300 CT RACK COVERED EMBEDDED METER SOCKET WITH METER HOOD AND SKIRT MILBANK 15T RT CT RATED METER SOCKET TEST SWITCH PROVIDED AND INSTALLED BY OTHERS DISTRIBUTION: MAIN BREAKER 400AF 3VA63 WITH DIAL ADJUSTABLE LSI ETU WITH PADLOCK DEVICE LED POWER INDICATOR LIGHT U T I L I T Y S P E C I F I C AT I O N S UTILITY METERING AMPERAGE METER SOCKET 400 AMPS 15T RT CT Rated Meter Socket Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation. 12 of 32 CUTHSEET FOR REFERENCE ONLY - SWITCHBOARD A ASSUMED WEIGHTS: 400# MINIMUM 600# MAXIMUM 6&(&+$5*(5($'<&86720(5'5$:,1* WůĞĂƐĞĐŽŶƐƵůƚƐĞƌǀŝŶŐƵƚŝůŝƚLJĨŽƌƚŚĞŝƌƌĞƋƵŝƌĞŵĞŶƚƐƉƌŝŽƌƚŽŽƌĚĞƌŝŶŐŽƌŝŶƐƚĂůůŝŶŐ͕ĂƐƐƉĞĐŝĨŝĐĂƚŝŽŶƐĂŶĚĂƉƉƌŽǀĂůƐǀĂƌLJďLJƵƚŝůŝƚLJ͕ĂŶĚŵĂLJƌĞƋƵŝƌĞůŽĐĂůĞůĞĐƚƌŝĐĂůŝŶƐƉĞĐƚŽƌĂƉƉƌŽǀĂů͘ůůŝŶƐƚĂůůĂƚŝŽŶƐŵƵƐƚďĞŝŶƐƚĂůůĞĚďLJĂůŝĐĞŶƐĞĚĞůĞĐƚƌŝĐŝĂŶĂŶĚŵƵƐƚĐŽŵƉůLJǁŝƚŚĂůůŶĂƚŝŽŶĂůĂŶĚůŽĐĂůĐŽĚĞƐ͕ůĂǁƐĂŶĚƌĞŐƵůĂƚŝŽŶƐ͘DŝůďĂŶŬƌĞƐĞƌǀĞƐƚŚĞƌŝŐŚƚƚŽŵĂŬĞĐŚĂŶŐĞƐŝŶƐƉĞĐŝĨŝĐĂƚŝŽŶƐĂŶĚĨĞĂƚƵƌĞƐƐŚŽǁŶǁŝƚŚŽƵƚŶŽƚŝĐĞŽƌŽďůŝŐĂƚŝŽŶ͘ $OOGLPHQVLRQVDUH´'UDZLQJYLHZVDUHQRWWRVFDOH ^tϬϮͲϮϯͲϮϰ  ZĞǀŝƐŝŽŶ͗ ϯK&ϱ^,d 13 of 32 CUTHSEET FOR REFERENCE ONLY - SWITCHBOARD A Project: Job #: Date: EQUIPMENT ANCHORAGE: WIND & SEISMIC LOADS Equipment: Model #: Component Info: Loads: Weight Wp =Wp = Length L =in.Fp = Width B =in.Fp* = Height H =in.Ev = HCOG =in.Fh = # Curbs:Fh* = Seismic Loading: ASCE Ch. 13 Fv = SDS =g z/h = Type of Equip: Ip =Component Importance Factor Supporting Building: Ta =s Ie = a1 =Ω0 =Wind Loading: ASCE Ch. 29 a2 =R =V = mph qh = 0.00256 KzKztKeV2 Hf =Rμ =Exp.:[26.7.3](26.10-1) h = ft. Component Seismic Loading:Kz =Kz per 26.10.1 CAR =Kzt =Kzt per 26.8.2 Rpo =Kd =Kd per 26.6 Ωop =Ke =Ke per 26.9 Fp per Eq. 13.3-1 through 13.3-3:G =Section 29.3.1 Fp, max = 1.6SDSIpW p B/s =Fh = GCfqhKdAs Fp, min = 0.3SDSIpW p Cf = Fp =g qh =psf Ev =g Fh =psf Fv =psf Increases Ry due to F* to account for load angle Reactions @ Base of Component (Total on Each Side of Length 'L'): # # Attachment Description: LC LC # # # 0 273 73 147 .9D+E 1.170 95 0.00 C 1.0 1.0 400 #400 # 1.00 0 0.85 0.88 Pe r T a b l e 13 . 6 - 1 2 Rx1 =0 73 273 164 2.00 100 + 30 concurrent orthogonal θ = DL EL WL .6D+.6W 0.00° Direction of Load: 1.044 1.000 224 Rx1 Ry1 51 Ω0 1.4 .6D+.7E 236- 1.00 2.0 0.85 21.03 0.351 21.03 0.234 ASD LRFD 140 # 523 # 546 # 94 # 56.0'' 147 # NA NA NA 21.5'' [13.3.1.1] [13.3.1.2] 1.0 Electrical: sheet metal NA 1.00 1.00 LR F D Anchor - ΩLRFD Anchor - LRFD 901 1.48 SRSS R / N 73 137 361 R / N 2 Resultant F* / F = Ry Overturning Incr = Ry1 =-200 338 City of Santa Ana Corp Yard 26035 5/1/2026 N* .9D+W -386 AX.1 Switchboard A Co m p o n e n t 64.0'' 42.7'' .9D+Ω0E 421 116 721 158 449 N**N = # of attachments per long side resisting Rx or Ry2 2 19.67 176 # 0.85 14 of 32 WIND LOADING GOVERNS, MINIMUM WEIGHT SHOWN DOES NOT GOVERN ANCHOR DESIGN Project: Job #: Date: Concrete Equipment Pad Foundation Design: Location: Service Loads: Overturning Stability Check: PDL =Superimposed weight of equipment MOT == M E/W + P E/W x (B/2 ±e p ) PE/W =0.6W or 0.7E; up or down Mr == 0.6 (PDL x [B/2 ± ep]+ Po x B/2) eP =Eccentricity of vertical loads D/C = Po =self-weight of pad ME/W =0.6W or 0.7E Pad Dimensions: L =Length B =Width t =Thickness D =Embedded Depth Allowable Soil Pressures σa1 =For sustained loads σa2 =For short-term loads (wind, seismic) σLB =Lateral bearing used w/ Cohesion σLB =Lateral bearing used w/ Friction Demand/Capacity Checks: DL Only D + 0.6W/0.7E 0.6D + 0.6W/0.7E P = M = e = Lb = σ = σa = D/C = Sliding: VE/W =0.6W or 0.7E σc =cohesion Cf =coefficient of friction Vr, sliding == σc x LB Vr, sliding == Cf x 0.6(PDL + Po) Vr, lat brg == σLB x B x D2 /2 Vr, lat brg == σLB x B x D2 /2 Vr, total =Vr, total = D/C = D/C = 874 ft-# 1500 psf 2467 # 0 ft-# 2000 psf 150 psf/ft 100 psf/ft 0.67 ft 105 # 0.00 ft AX.1 2572 # 0.0 ft 5.17 ft 4.00 ft 874 ft-# 400 # 2067 # 26.58% 130 psf 1233 # 0.25 4.00 ft 328 # 1500 psf 2000 psf 9.40% 2000 psf 6.50%7.96% 370 # 4.00 ft 130 psf 0 # 1233 # 0 # 370 # 0.00 ft 4.00 ft 119 psf 0.64 ft 188 psf 0.34 ft City of Santa Ana Corp Yard 26035 5/1/2026 88.60% 1375 # 874 ft-# 1085 ft-# 2960 ft-# 36.66% 15 of 32 MINIMUM WEIGHT GOVERNS SLIDING, DESIGN OK FOR 600# MAX EQUIPMENT WEIGHT MINIMUM PAD SIZE, ADD FOR OTHER EQUIPMENT FOR TOTAL SLAB DIM, TYP PROVIDE CODE MINIMUM REINFORCING: 12" x 8" x 0.0018 = 0.173 IN^2/FT REQUIRED PROVIDE #5 @ 12" = 0.20 IN^2/FT :: OK Project: Project #: Prepared By: Date: 16 of 32 CITY OF SANTA ANA CORP YARD CR 690 26035 AUSTIN SPINELLI SWITCHBOARD B Enclosure Specification Additional Information Shipping may loosen electrical connections. Check tightness before energizing. Bonded neutral - Remove neutral load conductors for test purposes only! Field-installed conductors shall be 60º C, 70º C, or 90º C, sized to 60º C rating for 110 amps or less; and 75º C or 90º C for 125 amps and above. D E T A I L S CP3F-L ENCLOSURE - 46"W x 64"H x 27"D TYPE 3R ENCLOSURE ALUMINUM ENCLOSURE MATERIAL PAINTED GRAY 208Y/120V 3PH 4 WIRE SCCR 50kA UTILITY - Unmetered SCE Charge Ready Program CATALOG SPECIFIC NAMEPLATE LABEL OF ESTIMATED WEIGHT INSIDE DIST DOOR MILBANK LUG LANDING COVERED EMBEDDED METER SOCKET WITH METER HOOD AND SKIRT DISTRIBUTION: MAIN BREAKER 600AF 3VA65 WITH DIAL ADJUSTABLE LSI ETU WITH PADLOCK DEVICE (2) 400A 3VA53 SUB-MAIN BREAKERS (2) 400A 30CKT 3PH PANELBOARD FOR BL BREAKERS (20) 50A 2P BOLT-ON BREAKERS FULLY RATED (2) 20A 1P BOLT-ON BREAKERS FULLY RATED FOR SPARES (1) 20A 1P BOLT-ON BREAKER FULLY RATED FOR GFI RECEPTACLE GFI RECEPTACLE 20A 120V (1) 20A 1P BOLT-ON BREAKER FULLY RATED FOR STRIP HEATER STRIP HEATER W/ THERMOSTAT U T I L I T Y S P E C I F I C AT I O N S CABINET AMPERAGE METER SOCKET 1000 AMPS UNMETERED Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation. 17 of 32 CUTHSEET FOR REFERENCE ONLY - SWITCHBOARD B ASSUMED WEIGHTS: 700# MINIMUM 900# MAXIMUM 46.06 64.13 46.44 CC HINGED EXTERIOR DOOR WITH DOOR STOP TO HOLD DOOR IN OPEN POSITION 21.50 27.02 44.56 46.06 9.37 13.89 3.00 IN. RECOMMENDED MIN. FOUNDATION EXTENSION ALL SIDES. DEPTH SHOULD BE DETERMINED BY SOIL CONDITIONS AND LOCAL CODE REQUIREMENTS SECTION C-C SCALE 1 : 20 6.78 STUD TO DOOR ID 16.00 .88 27.00 O.D. 17.27 PADLOCKABLE L-HANDLE WITH 3-POINT LATCH LIFTING EYES UTILITY SECTION CUSTOMER SECTION FOLLOW NEC 110-6 OR LOCAL REQUIREMENTS FOR MINIMUM CLEARANCES FRONT VIEW LOAD SIDE EQUIPMENT CP3F L-SIZE ALUM Material: Finish: Catalog No.: Title: Customer: Drawing No.: KANSAS CITY, MO USA Drawn By: Scale:NTS Date: .125 ALUMINUM CT-RATED (800A Max), 46" W x 27" D x 64" H OUTDOOR 3R RATED ENCLOSURE Sheet:1 of 302-16-21 Tolerances: Unless Specified OtherwiseX.X X.XX X.XXX X 2 .015 .03 .1 Third Angle Checked By: Approved By: Part Wt.: REV.DATE DESCRIPTION BY ** 1/19/20 NEW DRAWING BNM Shear/Die No.: PAINT PER CUSTOMER REQUEST BNM CP3F L-SIZE ALUM Square Inches: LBS. EA. ECO No. 046938 18 of 32CUTHSEET FOR REFERENCE ONLY - SWITCHBOARD B Project: Job #: Date: EQUIPMENT ANCHORAGE: WIND & SEISMIC LOADS Equipment: Model #: Component Info: Loads: Weight Wp =Wp = Length L =in.Fp = Width B =in.Fp* = Height H =in.Ev = HCOG =in.Fh = # Curbs:Fh* = Seismic Loading: ASCE Ch. 13 Fv = SDS =g z/h = Type of Equip: Ip =Component Importance Factor Supporting Building: Ta =s Ie = a1 =Ω0 =Wind Loading: ASCE Ch. 29 a2 =R =V = mph qh = 0.00256 KzKztKeV2 Hf =Rμ =Exp.:[26.7.3](26.10-1) h = ft. Component Seismic Loading:Kz =Kz per 26.10.1 CAR =Kzt =Kzt per 26.8.2 Rpo =Kd =Kd per 26.6 Ωop =Ke =Ke per 26.9 Fp per Eq. 13.3-1 through 13.3-3:G =Section 29.3.1 Fp, max = 1.6SDSIpW p B/s =Fh = GCfqhKdAs Fp, min = 0.3SDSIpW p Cf = Fp =g qh =psf Ev =g Fh =psf Fv =psf Increases Ry due to F* to account for load angle Reactions @ Base of Component (Total on Each Side of Length 'L'): # # Attachment Description: LC LC # # #SRSS -531 -211 2 114 Ry1 2 505 2 177 N* R / N N* R / N *N = # of attachments per long side resisting Rx or RyRx1 Ω0 2 165 LR F D Anchor - ΩLRFD Anchor - LRFD Ry1 =-450 760 755 183 262 350 355 1009 229 165 330Rx1 =0 165 229 137 115 .9D+E .9D+Ω0EDL EL WL .6D+.6W .6D+.7E .9D+W ASD LRFD Resultant F* / F =1.044 Ry Overturning Incr =1.000 0.351 19.67 0.234 21.45 21.45 Direction of Load:100 + 30 concurrent orthogonal θ =0.00° 1.00 0.85 0.72 1.51 0.85 Pe r T a b l e 13 . 6 - 1 1.4 1.00 2.0 0.85 2.00 1.0 1.0 C [13.3.1.1] [13.3.1.2]0 NA 1.00 NA 1.00 95 Electrical: sheet metal 1.0 NA NA 439 # 0 458 # 147 # 1.170 0.00 900 # Co m p o n e n t 900 # 46.0''316 # 21.5''330 # 64.0''211 # 42.7'' City of Santa Ana Corp Yard 26035 5/1/2026 AX.2 Switchboard B 19 of 32 SEISMIC LOADING GOVERNS, MAXIMUM WEIGHT SHOWN DOES NOT GOVERN ANCHOR DESIGN Project: Job #: Date: Concrete Equipment Pad Foundation Design: Location: Service Loads: Overturning Stability Check: PDL =Superimposed weight of equipment MOT == M E/W + P E/W x (B/2 ±e p ) PE/W =0.6W or 0.7E; up or down Mr == 0.6 (PDL x [B/2 ± ep]+ Po x B/2) eP =Eccentricity of vertical loads D/C = Po =self-weight of pad ME/W =0.6W or 0.7E Pad Dimensions: L =Length B =Width t =Thickness D =Embedded Depth Allowable Soil Pressures σa1 =For sustained loads σa2 =For short-term loads (wind, seismic) σLB =Lateral bearing used w/ Cohesion σLB =Lateral bearing used w/ Friction Demand/Capacity Checks: DL Only D + 0.6W/0.7E 0.6D + 0.6W/0.7E P = M = e = Lb = σ = σa = D/C = Sliding: VE/W =0.6W or 0.7E σc =cohesion Cf =coefficient of friction Vr, sliding == σc x LB Vr, sliding == Cf x 0.6(PDL + Po) Vr, lat brg == σLB x B x D2 /2 Vr, lat brg == σLB x B x D2 /2 Vr, total =Vr, total = D/C = D/C =18.52%61.74% 1483 # 445 # 0 # 0 # 1483 # 445 # 9.57% 10.51% 6.93% 275 # 130 psf 0.25 144 psf 210 psf 139 psf 1500 psf 2000 psf 2000 psf 0.00 ft 0.26 ft 0.50 ft 4.00 ft 4.00 ft 4.00 ft 2967 # 3114 # 1633 # 0 ft-# 821 ft-# 821 ft-# 0.00 ft 1500 psf 2000 psf 100 psf/ft 150 psf/ft 5.17 ft 4.00 ft 0.67 ft 147 # 3560 ft-# 0.0 ft 31.34% 2067 # 821 ft-# City of Santa Ana Corp Yard 26035 5/1/2026 AX.2 900 # 1116 ft-# 20 of 32 Project: Project #: Prepared By: Date: 21 of 32 CITY OF SANTA ANA CORP YARD CR 690 26035 AUSTIN SPINELLI TRANSFORMER ITEM QTY 1 1 2 1 3 2 4 3 5 4 6 2 7* 2 8* 2 NOTES: 1) 2) 3) 4) 5) CADD: CHKD:REV: SERIAL NO: ID TAG: FRONT & REAR PANEL - REMOVABLE HV TERMINAL LV TERMINAL PROVISIONS FOR Ø4" KNOCKOUT Parts List DESCRIPTION TOP COVER - REMOVABLE DIAGRAMATIC NAMEPLATE S.O. NO: WATERSHIELD RAIN DEFLECTOR CUST/JOB NAME: CUST ORDER NO: DWG FOR: 225 480D 208Y/120 2A4B 2 1/2% 10 10 TEMP RISE - °C: COOLING CLASS: WINDING COND: AA PAINT/COATING: ANSI 61 LIGHT GRAY HV-KV BIL: LV-KV BIL: PHASE: FREQ-HZ: KVA: HIGH VOLTAGE: LOW VOLTAGE: HV TAPS: CAD NO. PAGE 1 OF 1SCALE : N/A 3PH, 600V GENERAL PURPOSE DRY TYPE * TRANSFORMER OUTLINE, CASE D (CASE 6) THIS DRAWING IS NOT FOR CONSTRUCTION PURPOSES. VERIFY WITH FACTORY BEFORE CONSTRUCTION. TRANSFORMERS ARE MANUFACTURED AND TESTED PER APPLICABLE ANSI, NEMA, AND IEEE STANDARDS. UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS ARE IN INCHES WITH ± ¼" TOLERANCE. TRANSFORMER IS UL & CSA LISTED AND LABLED. * APPLIES TO OUTDOOR UNITS ONLY APPD:REVISIONS RECORD APPROVAL ALUMINUM COPPER 150 115 60 50 SINGLE HREE RECORD QUOTEAPPROVAL ALUMINUM COPPER 150 115 80 60 50 SINGLE HREE RECORD APPROVAL ALUMINUM COPPER 150 115 60 50 SINGLE HREE RECORD QUOTEAPPROVAL ALUMINUM COPPER 150 115 80 60 50 SINGLE HREE K4 OUTDOORINDOOR STANDARD DOE 2016 K13 K20 APPRX WT - LBS: 1580 HT225A3B2-D16 22 of 32CUTHSEET FOR REFERENCE ONLY - TRANSFORMER Project: Job #: Date: EQUIPMENT ANCHORAGE: WIND & SEISMIC LOADS Equipment: Model #: Component Info: Loads: Weight Wp =Wp = Length L =in.Fp = Width B =in.Fp* = Height H =in.Ev = HCOG =in.Fh = # Curbs:Fh* = Seismic Loading: ASCE Ch. 13 Fv = SDS =g z/h = Type of Equip: Ip =Component Importance Factor Supporting Building: Ta =s Ie = a1 =Ω0 =Wind Loading: ASCE Ch. 29 a2 =R =V = mph qh = 0.00256 KzKztKeV2 Hf =Rμ =Exp.:[26.7.3](26.10-1) h = ft. Component Seismic Loading:Kz =Kz per 26.10.1 CAR =Kzt =Kzt per 26.8.2 Rpo =Kd =Kd per 26.6 Ωop =Ke =Ke per 26.9 Fp per Eq. 13.3-1 through 13.3-3:G =Section 29.3.1 Fp, max = 1.6SDSIpW p B/s =Fh = GCfqhKdAs Fp, min = 0.3SDSIpW p Cf = Fp =g qh =psf Ev =g Fh =psf Fv =psf Increases Ry due to F* to account for load angle Reactions @ Base of Component (Total on Each Side of Length 'L'): # # Attachment Description: LC LC # # #SRSS -752 -258 2 147 Ry1 2 692 2 213 N* R / N N* R / N *N = # of attachments per long side resisting Rx or RyRx1 Ω0 2 293 LR F D Anchor - ΩLRFD Anchor - LRFD Ry1 =-800 1146 449 -210 322 -271 426 1384 158 293 586Rx1 =0 293 158 95 205 .9D+E .9D+Ω0EDL EL WL .6D+.6W .6D+.7E .9D+W ASD LRFD Resultant F* / F =1.044 Ry Overturning Incr =1.000 0.351 19.67 0.234 21.17 21.17 Direction of Load:100 + 30 concurrent orthogonal θ =0.00° 1.00 0.85 0.78 1.49 0.85 Pe r T a b l e 13 . 6 - 1 1.0 1.00 1.5 0.85 2.00 1.0 1.0 C [13.3.1.1] [13.3.1.2]0 NA 1.00 NA 1.00 95 Electrical: High-deformability 1.0 NA NA 303 # 0 316 # 123 # 1.170 0.00 1600 # Co m p o n e n t 1600 # 40.0''562 # 21.0''586 # 51.5''374 # 34.3'' City of Santa Ana Corp Yard 26035 5/1/2026 AX.3 Transformer 23 of 32 GOVERNS ANCHOR DESIGN, DESIGNED FOR Ω LEVEL LOADING Project: Job #: Date: Concrete Equipment Pad Foundation Design: Location: Service Loads: Overturning Stability Check: PDL =Superimposed weight of equipment MOT == M E/W + P E/W x (B/2 ±e p ) PE/W =0.6W or 0.7E; up or down Mr == 0.6 (PDL x [B/2 ± ep]+ Po x B/2) eP =Eccentricity of vertical loads D/C = Po =self-weight of pad ME/W =0.6W or 0.7E Pad Dimensions: L =Length B =Width t =Thickness D =Embedded Depth Allowable Soil Pressures σa1 =For sustained loads σa2 =For short-term loads (wind, seismic) σLB =Lateral bearing used w/ Cohesion σLB =Lateral bearing used w/ Friction Demand/Capacity Checks: DL Only D + 0.6W/0.7E 0.6D + 0.6W/0.7E P = M = e = Lb = σ = σa = D/C = Sliding: VE/W =0.6W or 0.7E σc =cohesion Cf =coefficient of friction Vr, sliding == σc x LB Vr, sliding == Cf x 0.6(PDL + Po) Vr, lat brg == σLB x B x D2 /2 Vr, lat brg == σLB x B x D2 /2 Vr, total =Vr, total = D/C = D/C =24.64%82.12% 1666 # 500 # 0 # 0 # 1666 # 500 # 12.83% 15.46% 10.10% 410 # 130 psf 0.25 192 psf 309 psf 202 psf 1500 psf 2000 psf 2000 psf 0.00 ft 0.33 ft 0.68 ft 4.00 ft 4.00 ft 3.97 ft 3332 # 3594 # 1737 # 0 ft-# 1174 ft-# 1174 ft-# 0.00 ft 1500 psf 2000 psf 100 psf/ft 150 psf/ft 4.33 ft 4.00 ft 0.67 ft 262 # 3998 ft-# 0.0 ft 42.48% 1732 # 1174 ft-# City of Santa Ana Corp Yard 26035 5/1/2026 AX.3 1600 # 1698 ft-# 24 of 32 OVERALL SLAB DIM = 5.167 x 2 + 4.33 = 14.667' SPECIFIED PAD = 15'-0" x 4'-0" :: OK www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: | Transformer Page: Specifier: E-Mail: Date: 1 5/1/2026 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 1/2 (2) hnom1 Item number: 2210260 KB-TZ2 1/2x3 3/4 SS304 Specification text: HILTI Æ 1/2 IN KWIK BOLT TZ2 - SS 304 WITH 2.5 IN NOMINAL EMBEDMENT DEPTH PER ICC-ES ESR-4266 , HAMMER DRILL BIT INSTALLATION PER MPII Effective embedment depth: hef,act = 2.000 in., hnom = 2.500 in. Material: AISI 304 Evaluation Service Report: ESR-4266 Issued I Valid: 12/1/2025 | 12/1/2027 Proof: Design Method ACI 318-19 / Mech Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b) Stand-off installation: Profile: Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 8.000 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) 25 of 32 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: | Transformer Page: Specifier: E-Mail: Date: 2 5/1/2026 Geometry [in.] & Loading [lb, in.lb] 26 of 32 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: | Transformer Page: Specifier: E-Mail: Date: 3 5/1/2026 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 692; Vx = 293; Vy = 0; Mx = 0; My = 0; Mz = 0; yes 60 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 692 293 293 0 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*692 8,906 8 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**692 1,172 60 OK * highest loaded anchor **anchor group (anchors in tension) 27 of 32 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: | Transformer Page: Specifier: E-Mail: Date: 4 5/1/2026 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-4266 f Nsa ³ Nua ACI 318-19 Table 17.5.2 Variables Ase,N [in.2]futa [psi] 0.10 120,404 Calculations Nsa [lb] 11,875 Results Nsa [lb]f steel f Nsa [lb]Nua [lb] 11,875 0.750 8,906 692 3.2 Concrete Breakout Failure Ncb = (ANc ANc0)y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1a) f Ncb ³ Nua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef )£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables hef [in.]ca,min [in.]y c,N cac [in.]kc l a f' c [psi] 2.000 6.000 1.000 5.500 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 36.00 36.00 1.000 1.000 2,404 Results Ncb [lb]f concrete f seismic f nonductile f Ncb [lb]Nua [lb] 2,404 0.650 0.750 1.000 1,172 692 28 of 32 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Company: Address: Phone I Fax: Design: Fastening point: | Transformer Page: Specifier: E-Mail: Date: 5 5/1/2026 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*293 5,426 6 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**293 1,683 18 OK Concrete edge failure in direction x+**293 2,376 13 OK * highest loaded anchor **anchor group (relevant anchors) When the input edge distance is set to "infinity", edge breakout verification is not performed in that direction 4.1 Steel Strength Vsa,eq = ESR value refer to ICC-ES ESR-4266 f Vsteel ³ Vua ACI 318-19 Table 17.5.2 Variables Ase,V [in.2]futa [psi]aV,seis 0.10 120,404 1.000 Calculations Vsa,eq [lb] 8,348 Results Vsa,eq [lb]f steel f Vsa,eq [lb]Vua [lb] 8,348 0.650 5,426 293 29 of 32 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Company: Address: Phone I Fax: Design: Fastening point: | Transformer Page: Specifier: E-Mail: Date: 6 5/1/2026 4.2 Pryout Strength Vcp = kcp [(ANc ANc0)y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) f Vcp ³ Vua ACI 318-19 Table 17.5.2 ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) ANc0 = 9 h2 ef ACI 318-19 Eq. (17.6.2.1.4) y ed,N = 0.7 + 0.3 (ca,min 1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) y cp,N = MAX(ca,min cac , 1.5hef cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) Nb = kc l a √f' c h1.5 ef ACI 318-19 Eq. (17.6.2.2.1) Variables kcp hef [in.]ca,min [in.]y c,N 1 2.000 6.000 1.000 cac [in.]kc l a f' c [psi] 5.500 17 1.000 2,500 Calculations ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] 36.00 36.00 1.000 1.000 2,404 Results Vcp [lb]f concrete f seismic f nonductile f Vcp [lb]Vua [lb] 2,404 0.700 1.000 1.000 1,683 293 30 of 32 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Company: Address: Phone I Fax: Design: Fastening point: | Transformer Page: Specifier: E-Mail: Date: 7 5/1/2026 4.3 Concrete edge failure in direction x+ Vcb = (AVc AVc0)y ed,V y c,V y h,V y parallel,V Vb ACI 318-19 Eq. (17.7.2.1a) f Vcb ³ Vua ACI 318-19 Table 17.5.2 AVc see ACI 318-19, Section 17.7.2.1, Fig. R 17.7.2.1(b)* AVc0 = 4.5 c2 a1 ACI 318-19 Eq. (17.7.2.1.3) y ed,V = 0.7 + 0.3(ca2 1.5ca1)£ 1.0 ACI 318-19 Eq. (17.7.2.4.1b) y h,V = √1.5ca1 ha ³ 1.0 ACI 318-19 Eq. (17.7.2.6.1) Vb = (7 (le da)0.2 √da)l a √f' c c1.5 a1 ACI 318-19 Eq. (17.7.2.2.1a) Variables ca1 [in.]ca2 [in.]y c,V ha [in.]le [in.] 6.000 6.000 1.000 8.000 2.000 l a da [in.]f' c [psi]y parallel,V 1.000 0.500 2,500 1.000 Calculations AVc [in.2]AVc0 [in.2]y ed,V y h,V Vb [lb] 120.00 162.00 0.900 1.061 4,799 Results Vcb [lb]f concrete f seismic f nonductile f Vcb [lb]Vua [lb] 3,394 0.700 1.000 1.000 2,376 293 *Anchor row defined by: Anchor 1; Case 3 controls When the input edge distance is set to "infinity", edge breakout verification is not performed in that direction 5 Combined tension and shear loads, per ACI 318-19 section 17.8 bN bV z Utilization bN,V [%]Status 0.590 0.174 5/3 47 OK bNV = bz N + bz V <= 1 31 of 32 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Company: Address: Phone I Fax: Design: Fastening point: | Transformer Page: Specifier: E-Mail: Date: 8 5/1/2026 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (EN1992-4, AS5216, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the equations remain in their imperial format. • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://viewer.joomag.com/profis-design-guide-us-en-summer-2021/0841849001625154758?short&/ • "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." • Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-19, Section 26.7. Fastening meets the design criteria! 32 of 32 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs E X X X X W WW W W W W W W E E E E E E E E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E 3 SS ECGR E E E E SS SS PI RD IR IR E E E EE E IR GT GT GT GT GT GT E 30'-3" (TYP) 8' ( T Y P ) 9' ( T Y P ) 30' 30' 30' E1 ELECTRICAL SITE LAYOUT SCE ID:00002141204 CITY OF SANTA ANA CORPORATE YARD 220 S DAISY AVE SANTA ANA, CA 92703 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S8 GG MW 02/17/26 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 12/04/2550% CONSTRUCTION DOCUMENTS 02/17/26100% CONSTRUCTION DOCUMENTS GENERAL NOTES LEGEND EXISTING EDGE OF PAVEMENT LINE EXISTING NATURAL GAS GEOPHYSICAL LINE EXISTING WATER LINE LIMITS OF WORK W W G G CONSTRUCTION NOTES EXISTING SANITARY LINE SS SS BL DD E E E E G GT D C D S C S W W W EXISTING BOLLARD EXISTING DOWN DRAIN EXISTING DROP INLET EXISTING ELECTRICAL BOX EXISTING ELECTRICAL PARKING STATION EXISTING ELECTRICAL RISER EXISTING ELECTRICAL TRANSFORMER EXISTING ELECTRICAL VAULT EXISTING ELECTRICAL LIGHT EXISTING NATURAL GAS METER EXISTING GATE EXISTING STORM DRAIN CLEANOUT EXISTING STORM DRAIN MANHOLE EXISTING SEWER CLEANOUT EXISTING SEWER MANHOLE EXISTING HANDICAP PARKING EXISTING SIGN EXISTING WATER MARKING POST EXISTING WATER RISER EXISTING WATER VALVE EXISTING WHEEL STOP EXISTING ELECTRICAL LINE E E EXISTING FENCE LINE PROPOSED TERMINAL BLOCK FOR LEVEL 2 CHARGER, PER DETAIL 1, SHEET E51 PROPOSED 400A 480V METERED SWITCHBOARD, PER DETAIL 2, SHEET E52 3 PROPOSED STEP DOWN TRANSFORMER, PER DETAIL 3, SHEET E5 4 INDICATE EVSE CHARGEPORT STALL PROPOSED DISTRIBUTION BOARD, PER DETAIL 4, SHEET E5 1. REFER TO CONDUIT AND WIRE SCHEDULE ON SHEET E2.0, E2.1, E2.2 FOR REQUIREMENTS. 2.CONDUIT ROUTING IS DIAGRAMMATICALLY SHOWN ON PLANS AND ARE ONLY APPROXIMATIONS. THE EXACT LOCATION AND ROUTING PATHS SHALL BE FIELD VERIFIED AND INSTALLED PER JURISDICTIONAL REQUIREMENTS. 3.UTILITY EQUIPMENT INSTALLATIONS AND PREP WORK SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY ENGINEER TO ENSURE ACCURACY OF INSTALLATIONS. 4.BOLLARD PROTECTION TO BE INSTALLED PER UTILITY SPECIFICATION. ADDITIONAL BOLLARD PROTECTION MAY BE REQUIRED AT THE DISCRETION OF THE UTILITY FILED INSPECTION PERSONNEL. 5.CONTRACTOR TO INSTALL TERMINAL BLOCK PRIOR TO CUSTOMER EVSE CHARGING DISPENSER BEING INSTALLED IN PHASE II 6.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION, 7.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 8.ALL CONDUITS SHALL COMPLY WITH CEC/NEC TABLE 300.5 MINIMUM BURIAL DEPTH, AND BE INSTALLED A MINIMUM OF 30" BELOW GRADE. 9.PER CEC/NEC 110.26 ”ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT.” 10.ALL ELECTRICAL WORK SHALL BE DESIGNED PER 2025 LOS ANGELES COUNTY ELECTRICAL CODE, 2025 CALIFORNIA ELECTRICAL CODE, 2023 NATIONAL ELECTRICAL CODE. 11.ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 12.PER CEC/ NEC 210.19 (A) INFORMATIONAL NOTE #4, "CONDUCTORS FOR BRANCH CIRCUITS AS DEFINED IN ARTICLE 100, SIZED TO PREVENT A VOLTAGE DROP EXCEEDING 3 PERCENT AT THE FARTHEST OUTLET OF POWER, HEATING, AND LIGHTING LOADS, OR COMBINATION OF SUCH LOADS, AND WHERE THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST OUTLET DOES NOT EXCEED 5%". **AC CONDUCTOR: 16FEET IS ADDED TO HORIZONTAL RUN LENGTH TO ACCOUNT FOR BURIED DEPTH - EXISTING 500KVA 480/277V 3Ø TRANSFORMER SCALE: CONDUIT SCHEDULE1 E1 NONE 1 4 PROPOSED UTILITY TRANSFORMER EXISTING BUILDING EXISTING PARCEL LINE EXISTING WALL (TYP) 2 1 1 1 1 1 1 1 1 1 1 PROPOSED CONDUIT TO BE INSTALLED ON WALL 4 4 4 4 4 4 4 4 4 3 4 2 3 0 2010105 SCALE: 1" = 10' PROPOSED SERVICE 600A 480/277V METERED SWITCHBOARD PROPOSED 300KVA STEP DOWN XFMR PROPOSED 1000A 208V SERVICE DISTRIBUTION E PROPOSED WHEELSTOP PROPOSED BOLLARD PROPOSED ELECTRICAL LINE PROPOSED L2 DUAL PORT WALL MOUNTED EV CHARGER E2 SINGLE LINE DIAGRAM SCE ID:00002141204 CITY OF SANTA ANA CORPORATE YARD 220 S DAISY AVE SANTA ANA, CA 92703 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S8 GG MW 02/17/26 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 12/04/2550% CONSTRUCTION DOCUMENTS 02/17/26100% CONSTRUCTION DOCUMENTS NOTES: 1.STANDARD RATED SERVICE PANELS, OVER CURRENT PROTECTION DEVICES AND WIRE SIZES BASED ON CEC/CEC REQUIREMENTS AT 125% CONTINUOUS LOAD. 100% RATED SERVICE PANELS, OVER CURRENT PROTECTION DEVICES AND WIRE SIZES BASED ON CEC/CEC REQUIREMENTS AT 100% CONTINUOUS LOAD. 2.PROPOSED UTILITY CTS/PTS SHALL BE LOCATED WITHIN COMPARTMENTS APPROVED BY THE UTILITY AS SHOWN IN THIS DRAWING PACKAGE. 3.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION. 4.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 5.CONTRACTOR TO INSTALL TERMINAL BLOCK PRIOR TO CHARGER BEING INSTALLED IN SEPARATE PERMIT. 1 3 PROPOSED SCE UTILITY TRANSFORMER GROUNDING ELECTRODE 5/8"X8'-0" COPPER CLAD GROUND ROD INSTALLATION PER NEC 250.52(A)(5), 250.53 (A) AND 250.68 INCOMING/ METER SECTION GR N D NE U T #6 SOLID AWG CU GROUNDING ELECTRODE CONDUCTOR PER NEC 250.66 (A) 600A 3P LSIG MANUFACTURER PROVIDED MAIN BONDING JUMPER PER CEC 250.24 (A)(4), 250.28(C),250.8(A)(7) DISTRIBUTION SECTION EV-XFMR-1 2 5 kVA 480-208V, "EV-SWBD-B" DISTRIBUTION SWITCHBOARD, 600A BUS, 600A MAIN, 208V, 3Ø, 4W, 42 KAIC, FULLY RATED, NEMA 3R L2-EVSE-1 CHARGE PORT 1 & 2 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-1 CHARGE PORT 1 & 2 50A 2P L2-EVSE-2 CHARGE PORT 3 & 4 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-2 CHARGE PORT 3 & 4 L2-EVSE-3 CHARGE PORT 5 & 6 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-3 CHARGE PORT 5 & 6 L2-EVSE-4 CHARGE PORT 7 & 8 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-4 CHARGE PORT 7 & 8 L2-EVSE-5 CHARGE PORT 9 & 10 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-5 CHARGE PORT 9 & 10 L2-EVSE-6 CHARGE PORT 11 & 12 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-6 CHARGE PORT 11 & 12 L2-EVSE-7 CHARGE PORT 13 & 14 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-7 CHARGE PORT 13 & 14 L2-EVSE-8 CHARGE PORT 15 & 16 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-8 CHARGE PORT 15 & 16 L2-EVSE-9 CHARGE PORT 17 & 18 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-9 CHARGE PORT 17 & 18 50A 2P 4 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P TERMINAL BLOCK (TYP) (SEE NOTE 5) L2-EVSE-10 CHARGE PORT 19 & 20 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-10 CHARGE PORT 19 & 20 50A 2P 50A 2P CONDUIT AND WIRING SCHEDULE FROM TO CONFIGURATION EXISTING UTILITY TRANSFORMER PROPOSED 400A 480V METERED SWITCHBOARD TBD (PER UTILITY DESIGN) PROPOSED 400A 480V METERED SWITCHBOARD PROPOSED 225KVA 480/208V STEP DOWN TRANSFORMER (3) 3/0 AWG CU (THWN-2) + (1) #3 AWG CU (THWN-2) EGC IN EACH OF (2) 2" SCH 40 PVC PROPOSED 225KVA 480/208V STEP DOWN TRANSFORMER PROPOSED 600A 208V DISTRIBUTION SWITCHBOARD (3) 350 MCM CU (THWN-2) + (1) 350 MCM CU (THWN-2) NEUT + (1) #2 AWG CU (THWN-2) SSBJ IN EACH OF (2) 3" SCH 40 PVC PROPOSED 600A 208V DISTRIBUTION SWITCHBOARD PROPOSED DUAL L2-EVSE (4) #4 AWG CU (THWN-2) + (1) # AWG CU (THWN-2) EGC IN (1) 1 1/2" RGS ABOVE GRADE, SCH 40 PVC BELOW GRADE 1 2 3 4 GROUNDING ELECTRODE 5/8"X8'-0" COPPER CLAD GROUND ROD INSTALLATION PER NEC 250.52(A)(5), 250.53 (A) AND 250.68 INCOMING/METER SECTION GR N D NE U T #6 SOLID AWG CU GROUNDING ELECTRODE CONDUCTOR PER NEC 250.66 (A) M 400A 3P MANUFACTURER PROVIDED MAIN BONDING JUMPER PER NEC 250.24 (A)(4), 250.28(C),250.8(A)(7) "EV-SWBD-A" METERED SWITCHBOARD, 400 AMP BUS, 400A MAIN, 480/277V, 3Ø, 4W 30KAIC(MINIMUM) SEE NOTE 2 MAIN BREAKER SECTION 2 20A 1P SPARE 2 3Ø, 4W, 480 E3 ELECTRICAL LOAD SCHEDULE TABLE SCE ID:00002141204 CITY OF SANTA ANA CORPORATE YARD 220 S DAISY AVE SANTA ANA, CA 92703 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S8 GG MW 02/17/26 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 12/04/2550% CONSTRUCTION DOCUMENTS 02/17/26100% CONSTRUCTION DOCUMENTS SCALE: SWITCHBOARD "EV-SWBD-A" LOAD SCHEDULE1 E3 NONE SCALE: SWITCHBOARD "EV-SWBD-b" LOAD SCHEDULE2 E3 NONE E4 ELECTRICAL CONDUIT ELEVATION AND GROUNDING DETAILS SCE ID:00002141204 CITY OF SANTA ANA CORPORATE YARD 220 S DAISY AVE SANTA ANA, CA 92703 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S8 GG MW 02/17/26 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 12/04/2550% CONSTRUCTION DOCUMENTS 02/17/26100% CONSTRUCTION DOCUMENTS NO SCALECALDWELL CONNECTION DETAIL 3 NO SCALEEV CHARGER CONDUIT ELEVATION VIEW 1 NOTES: 1.CONDUITS SHALL BE BURIED BELOW FROST LINE AND IN COMPLAISANCE WITH LOCAL AND NATIONAL CODE REQUIREMENTS. 2.REFER TO SHEET E3 FOR CONDUCTOR REQUIREMENTS WITHIN CONDUITS. 3.CONDUIT TO BE STUBBED OUT FOR FUTURE LOAD MANAGEMENT SOFTWARE. EXISTING TRANSFORMER PROPOSED UNDERGROUND SERVICE CONDUIT 2 PROPOSED 2" POWER CONDUIT (TYP) (2) PROPOSED 3" POWER CONDUIT (TYP) PROPOSED 600A 208V DISTRIBUTION PANEL TEMPORARY WALL MOUNTED TERMINAL BLOCK (TYP-11) 52-M 600/3 30CKT PANEL PROPOSED 400A METERED SWITCHBOARD 15 CL CT COMPARTMENT EUSERC 320 METER PANEL EUSERC 332 UGPS AND TERMINATION COMPARTMENT EUSERC 327 EUSERC 345 EUSERC 347 UL891 12" 30" 3" 21" 24" ACCESS OPENING 30"GB 52-M 400/3 UL891/SUSE PROPOSED 225 KVA STEP DOWN TRANSFORMER (1) PROPOSED 1 1/2" POWER CONDUIT (TYP) NO SCALEGROUNDING SCHEMATIC 2 NOTES: 1.COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. #2 AWG COPPER SSBJ #10 AWG COPPER EQUIPMENT GROUNDING CONDUCTOR GRND 52-M 600/3 30CKT PANEL GROUNDING ELECTRODE 5/8"X8'-0" COPPER CLAD GROUND ROD INSTALLATION PER NEC 250.52(A)(5), 250.53 (A) AND 250.68 CONCRETE ENCASED ELECTRODE PER NEC 250.52(A)(3)(1) OR (2) GRND NE U T NEUTRAL TO GROUND BOND PROPOSED 600A DISTRIBUTION PANEL PROPOSED 400A METERED SWITCHBOARD NEUTRAL TO GROUND BOND GROUNDING ELECTRODE 5/8"X8'-0" COPPER CLAD GROUND ROD INSTALLATION PER NEC 250.52(A)(5), 250.53 (A) AND 250.68 CONCRETE ENCASED ELECTRODE PER NEC 250.52(A)(3)(1) OR (2) #3 AWG COPPER EQUIPMENT GROUNDING CONDUCTOR FACTORY INSTALLED GROUND BAR 15 CL CT COMPARTMENT EUSERC 320 METER PANEL EUSERC 332 UGPS AND TERMINATION COMPARTMENT EUSERC 327 EUSERC 345 EUSERC 347 UL891 12" 30" 3" 21" 24" GB 52-M 400/3 UL891/SUSE NE U T GRND PROPOSED 225KVA STEP DOWN TRANSFORMER GRND TEMPORARY WALL MOUNTED TERMINAL BLOCK (TYP-11) E5 ELECTRICAL CONDUIT ELEVATION AND GROUNDING DETAILS SCE ID:00002141204 CITY OF SANTA ANA CORPORATE YARD 220 S DAISY AVE SANTA ANA, CA 92703 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S8 GG MW 02/17/26 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 12/04/2550% CONSTRUCTION DOCUMENTS 02/17/26100% CONSTRUCTION DOCUMENTS NO SCALEWALL MOUNTED TERMINAL BLOCK DETAIL 1 1 EAEATON B-LINE B22SH120 HDG, 12GA, 10' LENGTHS 5 EAUV STABILIZED NYLON CABLE TIES (1/4" WIDTH) 1 2 3 BILL OF MATERIALS FOR DETAILS ITEMREFERENCE NUMBER QUANTITY 1 EAVYNCKIER VM554 ENCLOSURE 1 EAVYNCKIER BACKING PLATE VMBP55A 1 EATERMINAL BLOCK BUSSMANN 14004-6, 90A, #4-14 AWG CU, 600 VAC 2 EAB-LINE 1/4 X 1.25" 20 HHCS ZINC 2 EAB-LINE SPRING NUT, N224, 1/4-20 PVC ELECTRICAL CONDUIT RISER 2 1.TERMINAL BLOCK AND TEMPORARY SUPPORT WILL BE REMOVED ONCE CHARGERS ARE INSTALLED. 2.SECURELY FASTEN PVC CONDUIT TO CONDUIT SUPPORT WITH 1/4" WIDE UV STABILIZED NYLON CABLE TIES. PROVIDE 1 TIE EVERY 12". 3.PARTS INCLUDING IN THE BILL OF MATERIALS ARE FOR 1 TEMPORARY TERMINAL BLOCK ONLY. SEE ELECTRICAL CONDUIT PLAN FOR LOCATION AND COUNT. NOTES: SECTION A-A 1 PVC ELECTRICAL CONDUIT RISER 6' - 0 ' ' ( M I N ) 3 2 NO SCALE400A METERED SWITCHBOARD DETAIL (OR EQUIVALENT)2 42 " 68"90 " 34"34" 3R EXTENSION 15 CL CT COMPARTMENT EUSERC 320 METER PANEL EUSERC 332 UGPS AND TERMINATION COMPARTMENT EUSERC 327 EUSERC 345 EUSERC 347 UL891 12" 30" 3" 21" 24" ACCESS OPENING 30"GB 52-M 400/3 SAW-TOOTH BARRIER DETAIL #3 UL891/SUSE DETAIL #2 FRONT ELEVATION SHOWN WITH 3R COMPONENTS REMOVED FOR CLARITY WEIGHT 1500LBS. 28 " 14 " 25.50" 19 . 5 0 " 25.50" 19 . 5 0 " 3R DOORS CAPABLE OF LOCKING AT 90° & 170° DETAIL #1 BASE PLAN REFER TO SHEET 3 FOR ANCHOR LOCATIONS NO SCALE600A DISTRIBUTION BOARD DETAIL (OR EQUIVALENT)4 PA N E L 32.00" 64 . 0 0 " 30.00" ACCESS FRONT DOOR FRONT ELEVATION FRONT ELEVATION SHOWN WITH 3R DOOR REMOVED FOR CLARITY SIDE SECTIONAL VIEW 32.00" 28.00" 30 . 0 0 " 1.00" 24 . 2 5 " 2. 3 8 " 2. 3 7 " 28.00" 21 . 8 8 " 1. 0 0 " ACCESS DOOR 0.75"X2" ANCHOR HOLES TYP (4) CONDUIT AREA 72CKT PANEL 52-M 600/3 NO SCALECHARGEPOINT CP6000 LEVEL 2 AC CHARGER SPECIFICATION 5 NOTE: CP6000 TO BE CAPPED AT 40FLA NO SCALE225KVA 480-208V STEP DOWN TRANSFORMER (OR EQUIVALENT)3 MEMORANDUM To: Jason Kwak Building Safety Manager Date: From: Subject: BUILDING PERMIT FOR CITY PROJECTS #26-6070 220 S. DAISY AVE. SANTA ANA, As a part of City project #26-6070, 220 S. Daisy Ave, Santa Ana, CA 92703 (Corporate Yard), electrical meters, pedestals, and (10) dual EVSE chargers will be installed. Installation of the proposed work is anticipated to take place in July 2026, with City Planning and Building inspection required prior to energizing. Being that these are City projects, we are requesting that all fees be waived for the subject properties. If you have any questions or need additional information, please contact Michael Ortiz at Ext. 5624. ________________________ Michael Ortiz Deputy Public Works Director Michael Ortiz (Mar 26, 2026 13:11:20 PDT) MEMORANDUM - No Fee Memo - EVSE - Corp Yard Final Audit Report 2026-03-26 Created:2026-03-25 By:Hortencia Martinez (hmartinez@santa-ana.org) Status:Signed Transaction ID:CBJCHBCAABAAguRlXhe-rkjT1ad2wrfpMU-aIXMWwB6r "MEMORANDUM - No Fee Memo - EVSE - Corp Yard" History Document created by Hortencia Martinez (hmartinez@santa-ana.org) 2026-03-25 - 6:13:04 PM GMT Document emailed to mortiz@santa-ana.org for signature 2026-03-25 - 6:13:08 PM GMT Email viewed by mortiz@santa-ana.org 2026-03-26 - 5:57:05 AM GMT Signer mortiz@santa-ana.org entered name at signing as Michael Ortiz 2026-03-26 - 8:11:18 PM GMT Document e-signed by Michael Ortiz (mortiz@santa-ana.org) Signature Date: 2026-03-26 - 8:11:20 PM GMT - Time Source: server Agreement completed. 2026-03-26 - 8:11:20 PM GMT