HomeMy WebLinkAboutCITY PROJECT - 1000 E Santa Ana Blvd & Unit EV - PlanAPN 988-398-02 APN 398-351-07 APN 398-203-02 AP N 3 9 8 - 3 5 1 - 0 8 APN 398-204-04 APN 931-10-445 APN 398-352-07 APN 398-352-06 C1 OVERALL SITE PLAN SCE ID:00002167308 CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S7 GG MW 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 05/01/26 12/02/2550% CONSTRUCTION DOCUMENTS 03/02/26100% CONSTRUCTION DOCUMENTS 05/01/26100% CONSTRUCTION DOCUMENTS REV1 LEGEND STANDARD ELECTRIC VEHICLE CHARGING STATION LIMIT OF WORK ACCESSIBILITY NOTES 1.ACCESSIBLE PATH OF TRAVEL AS INDICATED ON PLAN IS A BARRIER-FREE ACCESS ROUTE WITHOUT ANY ABRUPT LEVEL OF CHANGES EXCEEDING 1/2" IF BEVELED AT 1:2 MAX SLOPE OF VERTICAL LEVEL CHANGES NOT EXCEEDING 1/4" MAX, AND AT LEAST 48" IN WIDTH. SURFACE IS STABLE, FIRM AND SLIP RESISTANT. CROSS SLOPE DOES NOT EXCEED 2% AND SLOPE IN THE DIRECTION OF TRAVEL IS LESS THAN 5% UNLESS OTHERWISE INDICATED. ACCESSIBLE PATH OF TRAVEL SHALL BE MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS TO 80" MINIMUM AND PROTRUDING OBJECT GREATER 4" PROJECTION FROM WALL AND ABOVE 27" AND LESS THAN 80". 2.SEE SITE PLAN FOR MORE INFORMATION ON PATH OF TRAVEL. ACCESSIBLE ELECTRIC VEHICLE CHARGING STATION PROPOSED PATH OF TRAVEL EXISTING PATH OF TRAVEL 0 80404020 SCALE: 1" = 40' PROJECT LOCATION SEE SHEET C2 & E1 FOR IMPROVEMENTS PROPOSED METER LOCATION N S A N T I A G O S T E SAN T A A N A B L V D N S A N T I A G O S T E SAN T A A N A B L V D 26 SIGNED: 05/01/2026 CO M CO M CO M CO M CO M CO M CO M COM CO M E E E E E E E E E E E E E E E E E E E E E E CO M CO M CO M CO M CO M COM COM COM COM CO M E E E E E E E E E E E E 3 2 C W W IR W E C E E E U C E E E C E EC G R EC G R EC G R RR RR IR FD C IRIR FD C PI EE W U E IR IRIR IR FP FP FP FP IR IR IR IRIRIR U U W W W W WW W NO PA R K I N G EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y 18' (T Y P ) 8'- 5 " ( T Y P ) 12 ' 5' 9' 18' (T Y P ) 4'-6" ( T Y P ) EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y E E E E E E E E E E E E E EC G R EC G R RR RR NO PA R K I N G EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y 12 ' 5' 9' 18' (T Y P ) EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y CH A R G I N G ON L Y 0 40202010 SCALE: 1" = 20'C2 CIVIL SITE PLAN SCE ID:00002167308 CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S7 GG MW 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 05/01/26 12/02/2550% CONSTRUCTION DOCUMENTS 03/02/26100% CONSTRUCTION DOCUMENTS 05/01/26100% CONSTRUCTION DOCUMENTS REV1 1.FOR ELECTRICAL INFORMATION, SEE SHEET E1 1.CONTRACTOR SHALL LEGALLY DISPOSE OF ALL DEMOLISHED MATERIALS OFF SITE. 2.CONTRACTOR SHALL PROTECT ALL EXISTING UTILITY IMPROVEMENTS NOT SPECIFICALLY DESIGNATED FOR REMOVAL. 3.THE ON-SITE UNDERGROUND UTILITIES SHOWN ON THIS SHEET ARE AT AN APPROXIMATE LOCATION. THE EXTENT, LOCATIONS AND SIZES ARE UNKNOWN. THE CONTRACTOR SHALL POTHOLE TO LOCATE AND VERIFY THE UNDERGROUND UTILITY LINES PRIOR TO REMOVAL. 4.CONTRACTOR TO PROTECT AND PRESERVE IN PLACE ANY FOUND SURVEY MONUMENTS. ANY MONUMENTS DISTURBED SHALL BE RESET BY A LICENSED SURVEYOR AND THE APPROPRIATE PAPERWORK FILLED WITH THE CITY OR COUNTY. 5.ALL HAZARDOUS MATERIALS ENCOUNTERED DURING SITE DEMOLITION SHALL BE REMEDIATED AND DISPOSED OF PER STATE AND EPA REQUIREMENTS. 6.CONTRACTOR SHALL CONTACT AND COORDINATE WITH ALL UTILITY AGENCIES PRIOR TO THE START OF ANY DEMOLITION OR CONSTRUCTION. 7.ANY EXISTING UTILITIES AND/ OR IMPROVEMENTS THAT BECOME DAMAGED DURING CONSTRUCTION SHALL BE COMPLETELY RESTORED TO THE SATISFACTION OF THE OWNER AND AGENCY HAVING JURISDICTION, AT THE CONTRACTOR'S SOLE EXPENSE. GENERAL NOTES DEMOLITION NOTES LEGEND EXISTING EDGE OF PAVEMENT LINE EXISTING NATURAL GAS GEOPHYSICAL LINE EXISTING WATER LINE LIMITS OF WORK W W G G CONSTRUCTION NOTES EXISTING SANITARY LINE SS SS BL DD E E E E G GT D C D S C S W W W EXISTING BOLLARD EXISTING DOWN DRAIN EXISTING DROP INLET EXISTING ELECTRICAL BOX EXISTING ELECTRICAL PARKING STATION EXISTING ELECTRICAL RISER EXISTING ELECTRICAL TRANSFORMER EXISTING ELECTRICAL VAULT EXISTING ELECTRICAL LIGHT EXISTING NATURAL GAS METER EXISTING GATE EXISTING STORM DRAIN CLEANOUT EXISTING STORM DRAIN MANHOLE EXISTING SEWER CLEANOUT EXISTING SEWER MANHOLE EXISTING HANDICAP PARKING EXISTING SIGN EXISTING WATER MARKING POST EXISTING WATER RISER EXISTING WATER VALVE EXISTING WHEEL STOP EXISTING ELECTRICAL LINE E E EXISTING FENCE LINE 5 PROPOSED TRENCH AND PAVEMENT RESURFACING PER DETAIL 1, SHEET C31 PROPOSED L2 CHARGER FOOTING PER DETAIL 2, SHEET C32 3 PROPOSED CONCRETE EQUIPMENT PAD, PER DETAIL 3, SHEET C3 4 INDICATE EVSE CHARGEPORT STALL PROPOSED WHEELSTOP, PER DETAIL 4, SHEET C3 PROPOSED BOLLARD PER DETAIL 5, SHEET C3 ACCESSIBLE PARKING LAYOUT PER DETAIL,THIS SHEET EXISTING BUILDING (TYP) 1 2 3 (TYP) 4 (TYP) 5 EXISTING PARCEL LINE (TYP) N S A N T I A G O S T PROPOSED POLE AND OVERHEAD UTILITY TRANSFORMER 3Ø 120/240V EXISTING TREE GRATE (TYP) ACCESSIBLE PARKING LAYOUT SCALE: 1"=5' 1.ACCESS AISLES AT VEHICLE SPACES SHALL BE MARKED WITH A PAINTED BORDERLINE AROUND THEIR PERIMETER. 2.THE AREA WITHIN THE BORDERLINES SHALL BE MARKED WITH HATCHED LINES A MAXIMUM OF 36-INCHES ON CENTER. 3.THE COLOR OF THE BORDERLINES, HATCHED LINES, AND LETTERS SHALL CONTRAST WITH THAT OF THE SURFACE OF THE ACCESS AISLE. 4.THE BLUE COLOR REQUIRED FOR IDENTIFICATION ACCESS AISLES FOR ACCESSIBLE PARKING SHALL NOT BE USED. 5.ACCESS AISLE MARKINGS MAY EXTEND BEYOND THE MINIMUM REQUIRED LENGTH NOTES: 0.1 % TC: 136.51' EP: 136.51' (TYP) 4 0.1 % TP: 136.69' TC: 136.50' EP: 136.50' TP: 136.69' 0.8% 0.7% TP: 136.70' TP: 136.68' TP: 136.85' 0.9% 0.9% 0.9% TP: 136.86' TP: 136.86' TP: 136.87' 0.1 % 0.1 % EXISTING TREE GRATE (TYP) 0 10552.5 SCALE: 1" = 5' PROPOSED SERVICE 400A 120/240V METERED SWITCHBOARD E PROPOSED WHEELSTOP PROPOSED L2 SINGLE PORT EV CHARGER PEDESTAL W/ FOOTING PROPOSED BOLLARD PROPOSED ELECTRICAL LINE PROPOSED L2 DUAL PORT EV CHARGER PEDESTAL W/ FOOTING PROPOSED POLE AND OVERHEAD UTILITY TRANSFORMER 3Ø 120/240V 2 EXISTING CURB/GUTTER (TYP) EXISTING CONCRETE WALK (TYP) EXISTING RAILROAD LIGHT (TYP) 2 2 2 1 1 PROPOSED VAN ACCESSIBLE STALL 1 PROPOSED STANDARD ACCESSIBLE STALL 1 PROPOSED ACCESS AISLE 1 6 PROPOSED ISA SIGNAGE PER DETAIL 1, SHEET C3.1 6 1 1 26 SIGNED: 05/01/2026 C3 CIVIL DETAILS SCE ID:00002167308 CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S7 GG MW 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 03/02/26 12/02/2550% CONSTRUCTION DOCUMENTS 03/02/26100% CONSTRUCTION DOCUMENTS FIN GRADE SECTION PLAN 1. CONCRETE SHALL HAVE A MINIMUM ULTIMATE COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE 3,000 PSI 2. STEEL BAR REINFORCING SHALL CONFORM TO ASTM A615, GRADE 60 FUTURE EV CHARGER PER SHEET R00 MAX OPERATING WEIGHT = 200 LBS (3) #4 TOP AND BOTTOM, EACH WAY, PROVIDE STD HK AS REQUIRED FOR INSTALLATION 24" THICK CIP CONC SLOPED AWAY FROM EV CHARGER STD HK, TYP #4 CONT, TYP 2' 3" C L R 3" CLR "H " = 8 ' - 0 " M A X 2/ 3 " H " 2' - 0 " 2'-0" 1'-0" (TYP) FUTURE EV CHARGER CENTERED IN FOOTING MAX OPERATING WEIGHT = 200 LBS PROVIDE 1/2" EXPANSION JOINT WITH FILLER ADJ TO (E) HARDSCAPE AS OCCURS NO SCALEEV CHARGER FOOTING 2 1/2" HILTI KWIK BOLT TZ2 WITH 3" NOM EMBEDMENT, TOTAL PER MANUFACTURER RECOMMENDATION. SPECIAL INSPECTION IS NOT REQUIRED. 24 " M I N . T O T H E T O P OF H I G H E S T C O N D U I T 95% COMPACTED NATIVE BACKFILL NOTE: 1.ALL PATCHES TO PEDESTRIAN SURFACES SHALL COMPLY WITH 11B-302.1 AND 11B-303, TYP. 18" 36" 2" 3" 2"3" YELLOW PLASTIC WARNING TAPE TO BE REQUIRED ABOVE AND ALONG ENTIRE LENGTH OF DUCT BANK. SEE ELECTRICAL PLANS FOR CONDUIT SIZE, TYPE, AND WIRING REPLACE TOP SURFACE IN KIND, RECOMPACT SOIL TO 90% 12 " NO SCALETRENCH AND PAVEMENT RESURFACING 1 3" (TYP) FINISHED GRADE 3/4" CHAMFER (TYP) #5 @ 12" O.C. BOTH WAYS CENTERED IN SLAB 8" 4" M I N 7' 0" x 4' 0" 12 " 95% MINIMUM RELATIVE COMPACTED NATIVE BACKFILL PER ASTM D1557. OVER EXCAVATE 12" AND RECOMPACT 95% CONCRETE NOTE: 1.INSTALL ANCHORAGE TO SECURE EQUIPMENT PER E1 AND TYPICAL EQUIPMENT ANCHORAGE DETAIL. 2.MAXIMUM ENCLOSURE WEIGHT=2.000 LB. ENCLOSURE WEIGHT INCLUDES SWITCHBOARD, TRANSFORMER, AND DISTRIBUTION BOARD WEIGHTS. 3" C L R CONCRETE PAD DETAIL NO SCALE 3 NO SCALETYPICAL EQUIPMENT ANCHORAGE DETAIL 6 SWITCHGEAR - EACH MODULE 6" MIN EDGE DISTANCE (TYP) 6" MIN EDGE DISTANCE (TYP) EQUIPMENT BASE 1/2" DIAMETER SS 304/316 HILTI KWIK BOLT TZ EXPANSION ANCHOR WITH MINIMUM NOMINAL EMBEDMENT OF 2 1/2" REFER TO MANUFACTURER DWGS FOR ANCHOR ARRANGEMENT AND QUANTITY. CONCRETE SLAB TRANSFORMER EQUIPMENT BASE 1/2" DIAMETER SS 304/316 HILTI KWIK BOLT TZ EXPANSION ANCHOR WITH MINIMUM NOMINAL EMBEDMENT OF 2 1/2" CONCRETE SLAB NO SCALECONCRETE WHEEL STOP 4 SE E N O T E 1 *CONCRETE TO TEST AT 3000 PSI AT 28 DAYS FILL HOLE WITH NON-SHRINK GROUT PRECAST CONC WHEEL STOP #3 BARS PROPOSED AC PVMT 1" 1" #6 x 30" BAR AT EACH END 6" 2.5" 2" 6" 72" NO SCALEBOLLARD WITH FOUNDATION 5 NOTES: 1.CAUTION MUST BE TAKEN WHEN EXCAVATING TO NOT DISTURB EXISTING UNDERGROUND UTILITIES. 2.CONCRETE SHALL BE 3250 PSI MINIMUM AT 28 DAYS 3.USE 4 INCH GALVANIZED STEEL PIPE (0.25-INCH MINIMUM WALL) FILLED WITH CONCRETE AND PAINT "CAUTION YELLOW" FILL PIPE WITH CONCRETE EXISTING OR PROPOSED PAVEMENT YELLOW REFLECTIVE TAPE, 2" WIDE SLOPE FOOTING AWAY FROM PIPE AT 2% MIN SLOPE 24" 30 " 30 " 6" 26 SIGNED: 03/19/2026 TITLE SHEET T1 SCE ID:00002167308 CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S7 GG MW 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 05/01/26 12/02/2550% CONSTRUCTION DOCUMENTS 03/02/26100% CONSTRUCTION DOCUMENTS 05/01/26100% CONSTRUCTION DOCUMENTS REV1 CHARGE READY PROGRAM SOUTHERN CALIFORNIA EDISON SCE ID: 00002167308| CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SITE MAP VICINITY MAP PROJECT INFORMATION:OWNER/REPRESENTATIVE INFORMATION LIST OF CONSULTANTS UNDERGROUND SERVICE ALERT UTILITY NOTIFICATION CENTER OF SOUTHERN CALIFORNIA 811 OR (800) 422-4133 3 WORKING DAYS UTILITY NOTIFICATION PRIOR TO CONSTRUCTION CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING LOCATIONS, CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME ELECTRICAL: CAMERON CEDERLIND, PE NV5, INC 15092 AVENUE OF SCIENCE, #200 SAN DIEGO, CA 92128 858-385-0500 TITLE SHEET T1, T2 OVERALL SITE PLAN C1 CIVIL SITE PLAN C2 CIVIL DETAILS C3, C3.1 ELECTRICAL SITE LAYOUT E1 SINGLE LINE DIAGRAM E2 ELECTRICAL LOAD SCHEDULE TABLE E3 ELECTRICAL DETAILS E4, E5 CIVIL AND STRUCTURAL: NAT LLOYD NV5, INC 15092 AVENUE OF SCIENCE, #200 SAN DIEGO, CA 92128 559-676-7988 TRANSPORTATION ELECTRIFICATION PROJECT MANAGER: CHRIS KANOWSKY PROJECT MANAGER 6090 N IRWINDALE AVE SUITE B IRWINDALE, CA, 91702 310-803-4956 AREA OF WORK 2025 CALIFORNIA BUILDING CODE (CBC) 2025 CALIFORNIA ELECTRICAL CODE (CEC) NATIONAL ELECTRICAL CODE (NEC) 2023 DESIGN CRITERIA: UNDERGROUND SERVICE ALERT INDEX SHEET: SCOPE OF WORK 1.INSTALLATION OF LOAD-SIDE INFRASTRUCTURE FOR THE CHARGE READY PROGRAM 2.INFRASTRUCTURE TO SUPPORT 20 EVCS INCLUDING 1 VAN ACCESSIBLE AND 1 STANDARD ADA STALL PER CBC 11B-228.3.2.1. 3.(1) NEW 120/240V OVERHEAD TRANSFORMER BY SCE. 4.INSTALL (1) NEW 400A, 120/240V, 3Ø, 4W METERED SWITCHBOARD. 5.INSTALL (9) NEW DUAL TERMINAL BLOCKS AND (2) SINGLE TERMINAL BLOCKS FOR FUTURE L2 EV CHARGERS. 6.INSTALL PROTECTIVE EQUIPMENT FOR PROPOSED SWITCHGEAR AND TERMINAL BLOCKS. 7.RE-STRIPE (3) EXISTING STALLS FOR PROPOSED ADA STALLS. 8.CHARGER ARE NOT IN THIS SCOPE OF WORK AND ARE FOR REFERENCE ONLY. LOCATION: 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 1.TOTAL LOT SIZE: 5.4 ACRES 2.APN 988-398-02 CITY OF SANTA ANA OSCAR GUDINO OGUDINO@SANTA-ANA.ORG 951-254-4486 SITE LOCATION 1 PARKING SUMMARY: Total Number of Existing Parking Spaces 80 Total number of existing ADA parking spaces 2 Number of required EV spaces per CALGreen table 5.106.5.3.1 17 Total number of proposed public EVCS DCFC stalls 20 Proposed Standard ADA EVCS stalls per CBC Section 11B-228.3.2.1 1 Proposed Van ADA EVCS stalls per CBC Section 11B-228.3.2.1 1 1 26 SIGNED: 05/01/2026 T2 TITLE SHEET SCE ID:00002167308 CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S7 GG MW 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 03/02/26 12/02/2550% CONSTRUCTION DOCUMENTS 03/02/26100% CONSTRUCTION DOCUMENTS GENERAL GRADING AND DRAINAGE NOTES: THE REQUIREMENTS AND INFORMATION SET OUT BELOW ARE PROVIDED FOR THE CONTRACTOR'S CONVENIENCE AND DO NOT ENCOMPASS ALL PROJECT REQUIREMENTS DESCRIBED BY THE PROJECT PLANS AND SPECIFICATIONS AND/OR APPLICABLE LAWS, REGULATIONS AND/OR BUILDING CODES 1.CONSTRUCTION OF ALL PROJECT SITE IMPROVEMENTS SUBJECT TO ADA ACCESS COMPLIANCE, INCLUDING ACCESSIBLE PATH OF TRAVEL, CURB RETURNS, PARKING STALL(S) AND UNLOADING AREAS, BARRIER FREE AMENITIES AND/OR OTHER APPLICABLE SITE IMPROVEMENTS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT, CALIFORNIA TITLE 24, AND THE CALIFORNIA BUILDING CODE, CURRENT EDITION(S). 2.CONTRACTOR SHALL FIELD VERIFY ALL GRADE AND SLOPES PRIOR TO THE PLACEMENT OF CONCRETE AND/OR PAVEMENT FOR CONFORMANCE WITH ADA ACCESS COMPLIANCE REQUIREMENTS. EXAMPLES OF MINIMUM AND MAXIMUM LIMITS RELATED TO ADA ACCESS COMPLIANCE INCLUDE, BUT ARE NOT LIMITED TO: A) ACCESSIBLE PATH OF TRAVEL CROSS-SLOPE SHALL NOT EXCEED 2% B) ACCESSIBLE PATH OF TRAVEL LONGITUDINAL SLOPES SHALL NOT EXCEED 5% C) RAMP LONGITUDINAL SLOPES SHALL NOT EXCEED 8.33% WALKS SHALL NOT HAVE LESS THAN 48 INCHES IN UNOBSTRUCTED WIDTH. 3.CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER OF RECORD, IDENTIFIED BY THE PROFESSIONAL ENGINEERING SEAL AND SIGNATURE ON THESE PLANS, OF ANY SITE CONDITIONS(S) AND/OR DESIGN INFORMATION THAT PREVENTS THE CONTRACTOR FROM COMPLYING WITH THE LAWS, REGULATIONS AND/OR BUILDING CODES GOVERNING ADA ACCESS COMPLIANCE. 4.GROUND SLOPES AWAY FROM BUILDING PADS IN LANDSCAPED OR DIRT AREAS SHALL BE NO LESS THAN 5.0% FOR AT LEAST TEN (10) FEET, OR AS OTHERWISE NOTED ON THE PLANS. 5.DRAINAGE SHALL NOT BE ALLOWED ONTO ADJACENT PROPERTY. 6.ALL FILL MATERIAL USED TO SUPPORT THE FOUNDATIONS OF ANY BUILDING OR STRUCTURE SHALL BE PLACED UNDER THE DIRECTION OF A LICENSED GEOTECHNICAL ENGINEER, AND IN COMPLIANCE WITH THE PROJECT SPECIFICATIONS. A SOILS COMPACTION REPORT SHALL BE SUBMITTED TO THE ENGINEER OF RECORD AS REQUIRED BY THE PROJECT SPECIFICATIONS. 7.THE CONTRACTOR SHALL IMPLEMENT DUST CONTROL MEASURES AS REQUIRED BY THE PROJECT SPECIFICATIONS, AND BY GOVERNING PUBLIC AGENCIES. 8.CONTRACTOR TO MATCH EXISTING PAVEMENT GRADE AT ALL NEW PAVEMENT LOCATIONS UNLESS OTHERWISE NOTED ON THE PLANS. 1.CONTRACTOR SHALL PROVIDE ALL MATERIALS SUCH AS TOOLS, EQUIPMENT, LABOR, AND INCIDENTALS REQUIRED INCLUDING THE CONSTRUCTION OF ALL PROPOSED IMPROVEMENTS SHOWN ON THE PLANS AND AS SPECIFIED BY THE GOVERNING STANDARDS AND/OR THE CIVIL AND ELECTRICAL ENGINEERS. 2.CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION OF THE PROPOSED IMPROVEMENTS. 3.IF DAMAGED DURING CONSTRICTION, THE CONTRACTOR SHALL REPLACE IN KIND ALL EXISTING STRUCTURES, WALKWAYS, CURB & GUTTER, LANDSCAPING, AND/OR OTHER IMPROVEMENTS TO AN EXISTING OR BETTER CONDITION. 4.CONTRACTOR SHALL REPLACE ALL EXISTING STRIPING, SIGNAGE AND MARKINGS DAMAGED IN KIND DUE TO PROJECT CONSTRUCTION ACTIVITIES. 5.ALL WORK SHALL BE CONFINED WITHIN THE EASEMENTS AND/OR CONSTRUCTION LIMITS AS SHOWN ON THE PLANS. 6.APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK TO BE PERFORMED UNTIL A PERMIT OR NOTICE TO PROCEED HAS BEEN ISSUED 7.BEFORE COMMENCING WORK, THE CONTRACTOR SHALL NOTIFY ALL UTILITY AUTHORITIES OR UTILITY COMPANIES HAVING POSSIBLE INTEREST IN THE WORK OF THE CONTRACTOR'S INTENTION TO EXCAVATE PROXIMATE TO EXISTING FACILITIES AND THE CONTRACTOR SHALL VERIFY THE LOCATION OF ANY UTILITIES IN THE WORK AREA. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (U.S.A.) TWO (2) DAYS PRIOR TO BEGINNING ANY EXCAVATION. 8.THE CONTRACTOR SHALL OBTAIN WRITTEN AUTHORIZATION FROM ANY PROPERTY OWNER GIVING PERMISSION TO ENTER THE PROPERTY FOR THE PURPOSE OF CONSTRUCTING THE IMPROVEMENTS DELINEATED ON THE PLANS AND TRANSITION THERETO. 9.ALL BILL OF MATERIALS AND/OR EQUIPMENT SHALL BE PROVIDED AS SPECIFIED WITHIN THIS SET OR APPROVED EQUAL. ALL BULL OF MATERIALS AND/OR EQUIPMENT SHALL MATCH THE SAME QUALITY AND CAPACITY AS INDICATED HEREIN GENERAL CONTRACT NOTES: 1.LOCATIONS OF ALL UNDERGROUND FACILITIES ARE TAKEN FROM AVAILABLE MAPS AND RECORDS. ACTUAL FIELD LOCATIONS OF ALL UTILITIES MUST BE VERIFIED BY CONTRACTOR PRIOR TO TRENCHING. CONTACT USA DIGALERT, 1-800-227-2600, PRIOR TO DIGGING. 2.CONTRACTOR TO HAND-DIG ANY AND ALL LOCATIONS WHERE UNDERGROUND UTILITIES ARE SUSPECTED OR KNOWN. SURVEY NOTE: UTILITY NOTE: UTILITY INFORMATION SHOWN HEREON IS BASED ON RECORD INFORMATION SUPPLIED TO THE ENGINEER BY UTILITY COMPANIES, PUBLIC AGENCIES AND THE PROPERTY OWNER, TOGETHER WITH EVIDENCE GATHERED FROM SURFACE LOCATING METHODS AND OBSERVATION OF VISIBLE EVIDENCE BY A FIELD SURVEY. THE ENGINEER CAN MAKE NO GUARANTEE AS TO THE ACCURACY OR COMPLETENESS OF THE UNDERGROUND UTILITY FACILITIES SHOWN. PRIOR TO ANY SITE EXCAVATIONS, THE CONTRACTOR SHALL CONTACT THE OWNER AND UNDERGROUND SERVICE ALERT (U.S.A.) AND REQUEST THE THEY IDENTIFY THE LOCATION OF ALL UNDERGROUND UTILITIES AT THE SITE. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. FLOOD ZONE NOTES: 1.PROJECTED SITE LOCATION WITHIN FLOOD HAZARD ZONE X UNSHADED; AREA OF MINIMAL FLOOD HAZARD. 2.FIRM PANEL: 06059C0163J 3.MAP EFFECTIVE DATE; DECEMBER 3, 2009 DIGALERT NOTES CONCRETE NOTES: 1.CONCRETE COMPRESSIVE STRENGTH: ALL CONCRETE SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH AS SHOWN IN THE TABLE 1 BELOW AT 28 DAYS, U.N.O. ON PLANS. SEE ALSO SULFATE CONTENT NOTES. 2.AGGREGATES IN CONCRETE: SHALL BE NATURAL SAND AND ROCK (150 LB/CU. FT) CONFORMING TO ASTM C33. AGGREGATE SHALL HAVE PROVEN SHRINKAGE CHARACTERISTICS OF LESS THAN 0.04% PER ASTM C157. DO NOT CHANGE SOURCE OF AGGREGATE DURING COURSE OF WORK WITHOUT WRITTEN CONSENT OF ENGINEER. 3.CEMENT: SHALL BE PORTLAND CEMENT CONFORMING TO ASTM C150. CEMENT SHALL BE TYPE II OR AS REQUIRED TO SATISFY SITE SOIL CONDITIONS. REFER TO TABLE 1 FOR MAXIMUM WATER TO CEMENT RATIO. MINIMUM OF (6) SACKS OF CEMENT FOR EACH CUBIC YARD OF CONCRETE. *SLUMP SHALL BE MEASURED PRIOR TO THE ADDITION OF SUPERPLASTICIZER (IF USED.) REBAR CLEAR COVER CONCRETE: THE FOLLOWING MINIMUM CLEAR DISTANCES BETWEEN REINFORCING STEEL AND FACE OF CONCRETE SHALL BE MAINTAINED UNLESS NOTED OTHERWISE: 4.VIBRATION: VIBRATION OF CONCRETE SHALL BE IN ACCORDANCE WITH GENERAL PROVISIONS OUTLINES IN PORTLAND CEMENT ASSOCIATION SPECIFICATION ST26 5.CURING: CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF FIVE DAYS AFTER PLACEMENT. FOR CONCRETE OTHER THAN SLAB ON GRADE, APPROVE CURING COMPOUNDS MAY BE USED IN LIEU OF MOIST CURING ONLY IF APPROVED BY THE ENGINEER. 6.INSPECTIONS, TESTING & QUALITY ASSURANCE: A MINIMUM OF ONE COMPRESSION TEST AT 7 DAYS AND 2 TESTS AT 28 DAYS FOR ALL CONCRETE SAMPLE. TAKE TEST AT A FREQUENCY OF ONCE EVERY 150 CU. YDS OR 5,000 SQ. FT MINIMUM. 7.ANCHOR BOLTS, DOWELS, INSERTS: SHALL BE TIED IN PLACE PRIOR TO POURING CONCRETE. 8.CONSTRUCTION AND POUR JOINTS:LOCATIONS SHALL BE APPROVED BY ENGINEER PRIOR TO POURING CONCRETE. 9.FORMWORK:FORMWORK TOLERANCE SHALL BE IN ACCORDANCE WITH THE C.B.C. AND A.C.I. STANDARDS. 10.PIPES IN CONCRETE: PIPES MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES BUT SHALL NOT BE EMBEDDED THEREIN. PIPES OR DUCTS EXCEEDING ONE-THIRD THE SLAB OR WALL THICKNESS SHALL NOT BE PLACED IN THE STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED. 11.EXPOSED CORNERS: PROVIDE 3/4" CHAMFERS AT ALL EXPOSED CORNERS. 12.DRYPACK OR GROUT: CONCRETE STRENGTH SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI AND BE COMPOSED OF ONE PART PORTLAND CEMENT TO NOT MORE THAN THREE PARTS SAND. 13.FLY ASH: NOT PERMITTED. CONCRETE STRENGTH CONDITION MIN 28-DAY COMPRESSIVE STRENGTH, F'C CONCRETE TYPE* MAXIMUM AGGREGATE SIZE WATER TO CEMENT RATIO MAX SLUMP** SLAB ON GRADE/ CONC PADS 3,000 PSI NWC REBAR CLEAR OVER FOR CAST-IN-PLACE CONCRETE CONDITION COVER CONCRETE CAST AGAINST EARTH 3" MIN OTHERWISE 2" MIN SOIL NOTE: 1.ALLOWABLE BEARING PRESSURE IS ASSUMED 1,500PSF. 1.THE UNDERGROUND UTILITIES SHOWN HEREON HAVE BEEN LOCATED FROM UTILITY MARK OUTS PROVIDED BY CONAWAY GEOMATICS ON 11/06/2025. THE CERTIFYING SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE CERTIFYING SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH THEY DO CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. THE CERTIFYING SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 2.ELEVATIONS SHOWN HEREON ARE EXPRESSED IN US SURVEY FEET, BASED ON THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88), GEOID18, AND DERIVED FROM GPS OBSERVATIONS PER THE ADJUSTMENT IN THE BASIS OF BEARINGS STATEMENT, THE TOPOGRAPHIC SURVEY WAS PERFORMED USING BOTH GPS AND CONVENTIONAL OBSERVATIONS, WITH RELATIVE ACCURACY OF ±0.05' (CONVENTIONAL) AND ±0.1' (GPS). THE BASIS OF BEARINGS FOR THIS MAP IS THE INTERNATIONAL TERRESTRIAL REFERENCE FRAME 2020 (ITRF2020), DERIVED FROM THE TRIMBLE RTX (REAL TIME EXTENDED) SOLUTION, ADJUSTED TO THE 2025.85 EPOCH, NAD 83, ZONE 6. COORDINATES SHOWN HEREON ARE GROUND VALUES. USE THE FOLLOWING LOCAL SITE VALUES TO OBTAIN GRID VALUES: ·LOCAL SITE -LAT: 33°45'07.654490"N LON: 117°51'26.471452"W E HGT: 22.84 FT GSF:1.0000203949 ELEVATIONS SHOWN HEREON ARE EXPRESSED IN US SURVEY FEET, BASED ON THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88), AND ARE DERIVED FROM GPS OBSERVATIONS PER THE ADJUSTMENT SHOWN ABOVE. BASIS OF BEARINGS: 26 SIGNED: 03/19/2026 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs CO M CO M CO M CO M CO M CO M CO M COM CO M E E E E E E E E E E E E E E E E E E E E E E CO M CO M CO M CO M CO M COM COM COM COM CO M E E E E E E E E E E E E 3 2 C W W IR W E C E E E U C E E E C E EC G R EC G R EC G R RR RR IR FD C IRIR FD C PI EE W U E IR IRIR IR FP FP FP FP IR IR IR IRIRIR U U W W W W WW W NO PA R K I N G EV CH A R G I N G ON L Y EV CH A R G I N G ON L Y 18' (T Y P ) 8'- 5 " ( T Y P ) 12 ' 5' 9'18' (T Y P ) 4'-6" ( T Y P ) 0 40202010 SCALE: 1" = 20'E1 ELECTRICAL SITE LAYOUT SCE ID:00002167308 CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S7 GG MW 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 03/02/26 12/02/2550% CONSTRUCTION DOCUMENTS 03/02/26100% CONSTRUCTION DOCUMENTS GENERAL NOTES LEGEND EXISTING EDGE OF PAVEMENT LINE EXISTING NATURAL GAS GEOPHYSICAL LINE EXISTING WATER LINE LIMITS OF WORK W W G G CONSTRUCTION NOTES EXISTING SANITARY LINE SS SS BL DD E E E E G GT D C D S C S W W W EXISTING BOLLARD EXISTING DOWN DRAIN EXISTING DROP INLET EXISTING ELECTRICAL BOX EXISTING ELECTRICAL PARKING STATION EXISTING ELECTRICAL RISER EXISTING ELECTRICAL TRANSFORMER EXISTING ELECTRICAL VAULT EXISTING ELECTRICAL LIGHT EXISTING NATURAL GAS METER EXISTING GATE EXISTING STORM DRAIN CLEANOUT EXISTING STORM DRAIN MANHOLE EXISTING SEWER CLEANOUT EXISTING SEWER MANHOLE EXISTING HANDICAP PARKING EXISTING SIGN EXISTING WATER MARKING POST EXISTING WATER RISER EXISTING WATER VALVE EXISTING WHEEL STOP EXISTING ELECTRICAL LINE E E EXISTING FENCE LINE PROPOSED TERMINAL BLOCK, PER DETAIL 1, SHEET E51 PROPOSED METERED SWITCHBOARD, PER DETAIL 2, SHEET E52 INDICATE EVSE CHARGEPORT STALL 1. REFER TO CONDUIT AND WIRE SCHEDULE ON SHEET E2.0, E2.1, E2.2 FOR REQUIREMENTS. 2.CONDUIT ROUTING IS DIAGRAMMATICALLY SHOWN ON PLANS AND ARE ONLY APPROXIMATIONS. THE EXACT LOCATION AND ROUTING PATHS SHALL BE FIELD VERIFIED AND INSTALLED PER JURISDICTIONAL REQUIREMENTS. 3.UTILITY EQUIPMENT INSTALLATIONS AND PREP WORK SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY ENGINEER TO ENSURE ACCURACY OF INSTALLATIONS. 4.BOLLARD PROTECTION TO BE INSTALLED PER UTILITY SPECIFICATION. ADDITIONAL BOLLARD PROTECTION MAY BE REQUIRED AT THE DISCRETION OF THE UTILITY FILED INSPECTION PERSONNEL. 5.CONTRACTOR TO INSTALL TERMINAL BLOCK PRIOR TO CUSTOMER EVSE CHARGING DISPENSER BEING INSTALLED IN PHASE II 6.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION, 7.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 8.ALL CONDUITS SHALL COMPLY WITH CEC/NEC TABLE 300.5 MINIMUM BURIAL DEPTH, AND BE INSTALLED A MINIMUM OF 30" BELOW GRADE. 9.PER CEC/NEC 110.26 ”ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT.” 10.ALL ELECTRICAL WORK SHALL BE DESIGNED PER 2025 CALIFORNIA ELECTRICAL CODE, 2023 NATIONAL ELECTRICAL CODE. 11.ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 12.PER CEC/ NEC 210.19 (A) INFORMATIONAL NOTE #4, "CONDUCTORS FOR BRANCH CIRCUITS AS DEFINED IN ARTICLE 100, SIZED TO PREVENT A VOLTAGE DROP EXCEEDING 3 PERCENT AT THE FARTHEST OUTLET OF POWER, HEATING, AND LIGHTING LOADS, OR COMBINATION OF SUCH LOADS, AND WHERE THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST OUTLET DOES NOT EXCEED 5%". **AC CONDUCTOR: 16FEET IS ADDED TO HORIZONTAL RUN LENGTH TO ACCOUNT FOR BURIED DEPTH - PROPOSED SERVICE 400A 120/240V METERED SWITCHBOARD E PROPOSED WHEELSTOP PROPOSED L2 SINGLE PORT EV CHARGER PEDESTAL W/ FOOTING PROPOSED BOLLARD PROPOSED ELECTRICAL LINE PROPOSED L2 DUAL PORT EV CHARGER PEDESTAL W/ FOOTING PROPOSED POLE AND OVERHEAD UTILITY TRANSFORMER 3Ø 120/240 EXISTING BUILDING EXISTING PARCEL LINE (TYP) N S A N T I A G O S T PROPOSED POLE AND OVERHEAD UTILITY TRANSFORMER 3Ø 120/240V SCALE: CONDUIT SCHEDULE1 E1 NONE 1 2 1 1 1 1 2 2 2 3 2 2 1 E2 SINGLE LINE DIAGRAM SCE ID:00002167308 CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S7 GG MW 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 03/02/26 12/02/2550% CONSTRUCTION DOCUMENTS 03/02/26100% CONSTRUCTION DOCUMENTS GROUNDING ELECTRODE 5/8"X8'-0" COPPER CLAD GROUND ROD INSTALLATION PER NEC 250.52(A)(5), 250.53 (A) AND 250.68 1 PROPOSED SCE UTILITY TRANSFORMER, 150KVA 240/120V INCOMING/METER SECTION GR N D NE U T #6 SOLID AWG CU GROUNDING ELECTRODE CONDUCTOR PER NEC 250.66 (A) M 600A 3P MANUFACTURER PROVIDED MAIN BONDING JUMPER PER CEC 250.24 (A)(4), 250.28(C),250.8(A)(7) MAIN BREAKER SECTIONSEE NOTE 2 NOTES: 1.STANDARD RATED SERVICE PANELS, OVER CURRENT PROTECTION DEVICES AND WIRE SIZES BASED ON CEC/CEC REQUIREMENTS AT 125% CONTINUOUS LOAD. 100% RATED SERVICE PANELS, OVER CURRENT PROTECTION DEVICES AND WIRE SIZES BASED ON CEC/CEC REQUIREMENTS AT 100% CONTINUOUS LOAD. 2.PROPOSED UTILITY CTS/PTS SHALL BE LOCATED WITHIN COMPARTMENTS APPROVED BY THE UTILITY AS SHOWN IN THIS DRAWING PACKAGE. 3.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER DESCRIPTION. 4.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE OF ELECTRODES. 5.CONTRACTOR TO INSTALL TERMINAL BLOCK PRIOR TO CHARGER BEING INSTALLED IN SEPARATE PERMIT. L2-EVSE-1 CHARGE PORT 1 & 2 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-1 CHARGE PORT 1 & 2 DISTRIBUTION SECTION 50A 2P "EV-SWBD-A" METERED SWITCHBOARD, 600A BUS, 600A MAIN, 240V, 3 Ø, 4W, 42 KAIC, FULLY RATED, NEMA 3R L2-EVSE-2 CHARGE PORT 3 & 4 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-2 CHARGE PORT 3 & 4 L2-EVSE-3 CHARGE PORT 5 & 6 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-3 CHARGE PORT 5 & 6 L2-EVSE-4 CHARGE PORT 7 & 8 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-4 CHARGE PORT 7 & 8 L2-EVSE-5 CHARGE PORT 9 & 10 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-5 CHARGE PORT 9 & 10 L2-EVSE-8 CHARGE PORT 13 & 14 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-8 CHARGE PORT 13 & 14 L2-EVSE-9 CHARGE PORT 15 & 16 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-9 CHARGE PORT 15 & 16 L2-EVSE-10 CHARGE PORT 17 & 18 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-10 CHARGE PORT 17 & 18 L2-EVSE-11 CHARGE PORT 19 & 20 (40FLA+40FLA) (INSTALLED BY OTHERS) L2-EVSE-11 CHARGE PORT 19 & 20 50A 2P 2 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P 50A 2P L2-EVSE-6 CHARGE PORT 11 (40FLA) (INSTALLED BY OTHERS) L2-EVSE-7 CHARGE PORT 12 (40FLA) (INSTALLED BY OTHERS) L2-EVSE-6 CHARGE PORT 11 L2-EVSE-7 CHARGE PORT 12 TERMINAL BLOCK (TYP) (SEE NOTE 5) 3 CONDUIT AND WIRING SCHEDULE FROM TO CONFIGURATION PROPOSED TRANSFORMER PROPOSED 600A 240V METERED SWITCHBOARD TBD (PER UTILITY DESIGN) PROPOSED 600A 240V METERED SWITCHBOARD PROPOSED DUAL PORT LEVEL 2 (4) #6 AWG CU (THWN-2) + (2) #8 AWG CU (THWN-2) EGC IN (1) 1" SCH 40 PVC PROPOSED 600A 240V METERED SWITCHBOARD PROPOSED SINGLE PORT LEVEL 2 (2) #6 AWG CU (THWN-2) + (1) #8 AWG CU (THWN-2) EGC IN (1) 1" SCH 40 PVC 1 2 3 2 E3 ELECTRICAL LOAD SCHEDULE TABLE SCE ID:00002167308 CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S7 GG MW 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 03/02/26 12/02/2550% CONSTRUCTION DOCUMENTS 03/02/26100% CONSTRUCTION DOCUMENTS SCALE: SWITCHBOARD "EV-SWBD-A" LOAD SCHEDULE (SEE NOTE)1 E3 NONE NOTE: INCOMING SERVICE VOLTAGE WILL BE 240/120V 3Ø, 4W WITH CENTER TAP GROUND. CHARGING STATIONS MUST BE CONNECTED TO L1 & L2 ONLY. DO NOT CONNECT ANY PART OF THE SYSTEM TO L3, NEUTRAL IS NOT USED. E4 SCE ID:00002167308 CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S7 GG MW 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 03/02/26 12/02/2550% CONSTRUCTION DOCUMENTS 03/02/26100% CONSTRUCTION DOCUMENTS NO SCALECALDWELL CONNECTION DETAIL 3 NO SCALEEV CHARGER CONDUIT ELEVATION VIEW 1 NOTES: 1.CONDUITS SHALL BE BURIED BELOW FROST LINE AND IN COMPLAISANCE WITH LOCAL AND NATIONAL CODE REQUIREMENTS. 2.REFER TO SHEET E2 FOR CONDUCTOR REQUIREMENTS WITHIN CONDUITS. 3.SEE SHEET C3 FOR CONDUIT BURIAL DEPTHS. UTILITY TRANSFORMER PROPOSED UNDERGROUND SERVICE CONDUIT TEMPORARY TERMINAL BLOCK PROPOSED 600A METERED SWITCHBOARD (1) PROPOSED 1" POWER CONDUIT NO SCALEGROUNDING SCHEMATIC 2 NOTES: 1.COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. #8 AWG COPPER EQUIPMENT GROUNDING CONDUCTOR PROPOSED 600A METERED SWITCHBOARD GRND TEMPORARY TERMINAL BLOCK NE U T NEUTRAL TO GROUND BOND CONCRETE ENCASED ELECTRODE PER NEC 250.52(A)(3)(1) OR (2) GRND GROUNDING ELECTRODE 5/8"X8'-0" COPPER CLAD GROUND ROD INSTALLATION PER NEC 250.52(A)(5), 250.53 (A) AND 250.68 ELECTRICAL DETAILS E5 ELECTRICAL DETAILS SCE ID:00002167308 CITY OF SANTA ANA TRANSPORTATION CENTER 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 SOUTHERN CALIFORNIA EDISON CO. CHARGE READY PROGRAM 2244 WALNUT GROVE AVENUE ROSEMEAD, CA 91770 TEL: (800) 665-4555 S7 GG MW 07/08/25HLSP/SLD 877.706.6858 www.NV5.com 03/02/26 12/02/2550% CONSTRUCTION DOCUMENTS 03/02/26100% CONSTRUCTION DOCUMENTS NO SCALETERMINAL BLOCK DETAIL 1 1 EAEATON B-LINE B22SH120 HDG, 12GA, 10' LENGTHS 5 EAUV STABILIZED NYLON CABLE TIES (1/4" WIDTH) 1 2 3 1 BILL OF MATERIALS FOR DETAILS ITEMREFERENCE NUMBER QUANTITY 1 EAVYNCKIER VM554 ENCLOSURE 1 EAVYNCKIER BACKING PLATE VMBP55A 1 EATERMINAL BLOCK BUSSMANN 14004-6, 90A, #4-14 AWG CU, 600 VAC 2 EAB-LINE 1/4 X 1.25" 20 HHCS ZINC 2 EAB-LINE SPRING NUT, N224, 1/4-20 PVC ELECTRICAL CONDUIT RISER CONCRETE PAD CONCRETE CURB, WHEN APPLICABLE, SEE PLAN 2' - 0 ' ' ( M I N ) 1' - 6 ' ' ( M I N ) 6' - 0 ' ' ( M I N ) FINISHED SURFACE PVC ELECTRICAL CONDUIT RISER SE E D E T A I L 3 3 2 2 1.TERMINAL BLOCK AND TEMPORARY SUPPORT WILL BE REMOVED ONCE CHARGERS ARE INSTALLED. 2.SECURELY FASTEN PVC CONDUIT TO CONDUIT SUPPORT WITH 1/4" WIDE UV STABILIZED NYLON CABLE TIES. PROVIDE 1 TIE EVERY 12". 3.PARTS INCLUDING IN THE BILL OF MATERIALS ARE FOR 1 TEMPORARY TERMINAL BLOCK ONLY. SEE ELECTRICAL CONDUIT PLAN FOR LOCATION AND COUNT. NOTES: SECTION A-A SH E E T 3 NO SCALE600A METERED SWITCHBOARD DETAILS (OR EQUIVALENT)2 28 " 14 " 68" SECTION C-C 90 " 40 . 2 5 " BO L T 34"34" 90 " 84 " SIDE ELEVATIONFRONT ELEVATION CONDUIT AREA BUS WORK UTILITY CONDUIT AREA VESTIBULE ENCLOSURE DOORS TO OPEN 170° MAX NO SCALECHARGEPOINT CP6000 3 NOTE: CP6000 TO BE CAPPED AT 40FLA NOTE: INCOMING SERVICE VOLTAGE WILL BE 240/120V 3Ø, 4W WITH CENTER TAP GROUND. CHARGING STATIONS MUST BE CONNECTED TO L1 & L2 ONLY. DO NOT CONNECT ANY PART OF THE SYSTEM TO L3, NEUTRAL IS NOT USED. MEMORANDUM To: Jason Kwak Building Safety Manager Date: From: Subject: BUILDING PERMIT FOR CITY PROJECTS #26-6071 1000 E SANTA ANA BLVD, As a part of City project #26-6071 1000 E SANTA ANA BLVD, SANTA ANA, CA 92701 (SARTC), electrical meters, pedestals, and (10) dual EVSE chargers will be installed. Installation of the proposed work is anticipated to take place in July 2026, with City Planning and Building inspection required prior to energizing. Being that these are City projects, we are requesting that all fees be waived for the subject properties. If you have any questions or need additional information, please contact Michael Ortiz at Ext. 5624. ________________________ Michael Ortiz Deputy Public Works Director Michael Ortiz (Mar 26, 2026 13:11:47 PDT) MEMORANDUM - No Fee Memo - EVSE - SARTC Final Audit Report 2026-03-26 Created:2026-03-25 By:Hortencia Martinez (hmartinez@santa-ana.org) Status:Signed Transaction ID:CBJCHBCAABAAImzTn00rZikXw_X2PVgG7saLc1qeSlP3 "MEMORANDUM - No Fee Memo - EVSE - SARTC" History Document created by Hortencia Martinez (hmartinez@santa-ana.org) 2026-03-25 - 6:12:06 PM GMT Document emailed to mortiz@santa-ana.org for signature 2026-03-25 - 6:12:10 PM GMT Email viewed by mortiz@santa-ana.org 2026-03-26 - 5:54:55 AM GMT Signer mortiz@santa-ana.org entered name at signing as Michael Ortiz 2026-03-26 - 8:11:45 PM GMT Document e-signed by Michael Ortiz (mortiz@santa-ana.org) Signature Date: 2026-03-26 - 8:11:47 PM GMT - Time Source: server Agreement completed. 2026-03-26 - 8:11:47 PM GMT