HomeMy WebLinkAbout10145871.pdf9 The contractor shall verify and be responsible for all dimensions and conditions at the job site. The contractor shall be responsible for bracing and shoring all excavations, temporary structures, and partially completed portions of the work. All conditions not specifically shown or detailed shall be of the same type and character as those shown for similar conditions. All work and material shall conform to the UBC97 Code and the latest edition local codes. FOUNDATIONS Footings shall rest on firm undisturbed natural or compacted soil at a minimum depth below finish grade as shown on drawings. Allowable soil bearing values are based on 1,000 psf. All Holdowns shall be in place prior to foundation inspection. CONCRETE Concrete shall have a minimum ultimate compressive strength of 2,500 psi at 28 days. All grade beam concrete shall have compressive strength of 3,000 psi minimum at 28 days unless noted otherwise. LUMBER All structural lumber shall be graded in accordance with the grading and dressing rules of the west coast lumberman's association. All wood bearing on concrete shall be pressure treated Douglas fir. Holes for bolts shall be bored with a bit (1 /32" to 1/16") larger than the normal bolt diameter. All bolts shall be pre -tightened prior to application of plywood, plaster, etc. 2X solid blocking shall be placed between joists or rafters at all supports. Cross -bridging shall be provided at 8'o.c. max. for all floor and ceiling joists with the ratio of depth to width equals six to one min. All structural plywood shall be structural I . Each sheet shall be identified by a registered stamp. Plywood shall be 15132, plywood span is 24" O.C., 8D Typ. nailing shall be 6" in perimeter and 12" in field. Provide 2X fire stops at all intersections of stud walls and / or stud partitions at floor, ceiling and roof. Place fire stops at a maximum spacing of 8' in the vertical direction, provide 2X fire stops in all furred spaces, vertical and horizontal. At a maximum spacing of 8' in each direction and at the same line as fire stops in adjacent stud partitions and walls. All structural lumber shall be Douglas fir -larch #2 for joists and 4X lumber; Douglas fir -larch #1 for GX lumber minimum unless noted otherwise. All structural Glulam lumber shall be 24F-V8 DF/DF for simple supported beams and 24F-V4 DF1DF for all cantilever beams. Use 24F-V4 DF/DF for simple suported Glulam beams typical. Use 24F-V8 DF/DF for cantilever Glulam beams typical. 3/8" structual 1 plywood with 8d nails at 6" O.C. at edges, 12" O.C. field. PLUMBING Water closet shall have no more than 1.6 gallons per flush (PC402.0). Shower doors shall be temper glass with compliance CPR4 H-R-C- St& - LOT NOTES Sq. ft. of lot size (6,228 0) Sq. ft. of house (1,4910 Sq. ft. of addition (115.5 Sq. ft. of hall (60 0) Total sq. ft. of house & addition (1,606.5 0) plus hall (60 0) Total: (1,666.5 0) Total sq. ft. of open lot area (4621.5 0) 10, (115.93') SEE DETAIL KA�12' 428 sq.ft, 4 4f 5# 755.25 sq.ft. 1,282.5 sq.ft. 4f 11'6" 451 AJ 1NC,'T!1V1S10N MASTEIP" A 401 22' 41 A,40 e�ffi 0,� X 00 C*4 40 G 4f 4f 43 40' Lot 9 AC 4 . Tract 1448 ti! APN:005-045-21 40' is set a SITE PL/\Im 'VWJI 06 APPROX. SCALE: 1" 10' ty of S-Int T1 a accepu 40' tlli 1Cqld n PERMITTYPE* ELECT PLEG C H N INU (�RADG G PERMIT#. CONSTR-TYPE CODE FLOOD ZONE CERTIF FIEQ'D VERSA TI Lt-- Revision Date Description design Wabotte - wwmereattlMe-eignmet Office (714) W-5177 Call M4) 651-8W, 2 15/19/05 Submittal to kthe'ek, E-mail - JanicadWreatileAcolon.nat tDwg No. Drawn by: Beach ClVas, Orange CountyI of 6 SITE PLAN Utility Room Addition with 3/4 Bath OWNER Herman Rodriguez 1114 W. 16 th STREET SANTA ANA, CALIFORNIA k%U40d Proposed Utility Room and 3/4 Bath (1.15 sq.ft.) 2Cx 1 0 Window to 7' Match Existing 4X6 Header —01 26" 2'6" Pocket Door n 3/4 Bath 51 30x 20Window to Match Existing 4X6 Header 3' E 32" Solid Core Door 4X6 Header W8 16V' Bedroom 36" Concrete Landing @ Exterior Door 3' Removed exis 70x 50Windom with min. 4'ar( 4! 0 0) Hobbe Room FT�oset] Convert Exterior Space to Interior Halfway (60 sq. ft.) Walls to be Drywall to Match 20' Existing Interior Walls.—/ Garage 26' FLOOR PLAN 4'.9" x 2'.7" Aluminum window (Typ.) 22' Bedroom Bedroom Baths Cs� Bath 45' Ling Closet Kitchen replace hway n Its V door r-5 Living Room Family Room LEGEND: 'Smoke Detector I" Drop Entry 37' Dinning ft 1x8 Barge Rafter ,— R-30 I x8 Facia 4x6 4X6 2x6 Rim Joist 1/2" Drywall 71611 Solid Fire Blocking Blocking Throughout (Typ.) 2x6 Stud 16" O.C. (Typ.) Pluiming 4d 2X4 P.T. Plate L 4 a Full Length 4 Trimmers (Typ.) SEE DETAIL FRAMING PLAN SEE DETAIL NOT TO SCALE 2X6 Rafters @ 24" O.C. 15/32, #2 or Better Roof Sheating Staggard (Typ.) - 4"W to Match Existing W/ 2X6 Solid Block With A-35 24"O.C. ROOF FRAMING PLAN NOT TO SCALE Maw 6 K = m ter m m � m m � m m ... m m m mm New Addition Roof to ST-3C� Match Existing 3 & 12 SEE DE TAIL - j �,4 Slope With _ Comp Roofing - — — — — — — — — — — — — — — — — — Foundation Cricket W128 Gage Flashing (Typ.) See Roof Slope Detail Below 1 12" CD ST-36 rD"� EE DETAIL 4 r I�o� FLAT — — — — — — — — — — — — — — I — — — — — — -- L ------- ---- NOTE: New Drain Shall Connect ROOF PLAN — to Main Sewer APPROX. SCALE: I" = 10' 29 1/201 O.H. 4f ROOF SLOPE DETAIL NOT TO SCALE Revisior1. .Description VERSA"fl E ded gn Wabefte - www.verroaNledesign.nat Office (714) 540-5177 Call (714) 661-894eNL Submittal to Plan Check E-mall - Janice0vareaWledeeign.nat Desch Cltie% Orange County Dwg. No. 2 of 6 Drawn by: 1 FLOOR, ROOF AND FRAMING PLAN OWNER Herman Rodriguez 1114 W. 16 th STREET SANTA ANA, CALIFORNIA Stucco (typ.) NORTH FRONT ELEVATION NOT TO SCALE Am SOUTH BACK ELEVATION NOT TO SCALE A ":- 1 9 14 CA n 4 rl-of 0 11-4- 161611 Proposed New Addition EAST SIDE ELEVATION NOT TO SCALE Openable 3° x 1 0 Window Slider to Match Existing 'I of 7 proposed New addition Exterior Siding to Match Existing Grade D paper 3/8" for Water Behind Siding (Typ.) Revision 1 Description VVoo, �,i-A TI IL li 1 dej gn Webefte — wwmareatilmloolp.nat Office M4) M"M Call, M4) 651-e�W Submiffal to Plan Check E-mail — I Dw. Drawn by: Desch Cltla% Oranee County gNo 3 of 6 Date. 5/19/05 ELEVATION PLAN OWNER Herman Rodriguez 1114 W. 16 th STREET SANTA ANA, CALIFORNIA Dv IT out ftf A, Pula 2x4 P.T.D.F. Mudsill W1 518", 0 A.B. 7" Into Concrete 12" From Corners and 6'0.C. Max. Ea. A.B. W/ 2" x 2" x 3/16" Plate Washer 3 1/2" Thick Concrete Slab With Wire Mesh 6 Mil Polyethylene Moisture Barrier Membrane With 2" Sand Base Rebar Top and Bottorn—A t— '— MIN. I 3/8 " Siding to Match Existing R-1 3 FOOTING DETAIL NOT TO SCALE jol t Existing Residence EXISTING GARAGE Compact Natural Grade Existing Wall New Wall ST-36 (Typ.) to New & Existing Wall for Postive Connection DETAIL NOT TO SCALE FOUNDATION DETAIL NOT TO SCALE C%-#- -If-% I-r. _ N Addv&& ATTACHMENT DETAIL NOT TO SCALE SHEAR WALL SCHEDULE 1. 1/4" drywall with 5d cooler nails at 7" o.c. edge and field (Table 47-1, U.B.C.) - 50 #/ft 2. 5/8" drywall with 6d cooler nails at 7" o.c. edge and field (Table 47-1, U.B.C.) - 50 #/ft 3. 1/2" drywall with 5d cooler nails at 4" o.c. edge and field (Table 47-1, U.B.C.) - 62 #/ft 4. 5/8" drywall with 6d cooler nails at 4" o.c. edge and field (Table 47-1, U.B.C.) - 62 #/ft 5. 1/2" blocked drywall with 5d cooler nails at 4" o.c. edge and field (Table 47-1, U.B.C.) 75 #/ft 6. 5/8" blocked drywall with 6d cooler nails at 4" o.c. edge and field (Table 47-1, U.B.C.) 87 #/ft 7. 7/6' stucco over lath with 16 gauge by 7/8" staples at 6" o.c. at top and bottom plates, edge and field nailing 180 #/ft (I.C.13.0, Report No. 1823, May 1972 or I.C.B.O. Report No. 1823, May 1972) 8. 7/8" stucco over lath with 16 gauge by 7/8" staples at 3" o.c. edge nailing and 6" o.c. field nailing - 325 #/ft (I.C.13.0, Report No. 1823, May 1972 or I.C.B.O. Report No. 1318, February 1973) 9. 3/8" Structual I plywood with 8d nails at 6" o.c. at edges, 12" o.c. field. - 264 #/ft 10. 3/8" CDX plywood with 8d nails at 4" o.c. at edges, 12" o.c. field (Table 25-K, U.B.C.) - 384 #/ft 11. 3/8" Structural 11 plywood with 8d nails at 3" o.c. at edges, 12" o.c. field (Table 25-K, U.B.C.) - 492 #/ft 12. 3/8" Structural 11 plywood with 8d nails at 2" o.c. staggered at edges with 3x nominal stud, 12" o.c. field - 636 #/ft (Table 25-K, U.B.C.) 13. 15/32" Structural I plywood with 10d nails at 3" o.c. staggered at edges with 3x nominal stud, 12" o.c. field - 665 #/ft (Table 25-K, U.B.C.) 14. 15/32" Structural I plywood with 10d nails atToc. staggered at edges with 3x nominal stud, 12" o.c. field - 870 #/ft (Table 25-K, U.B.C.) mu w"t 1:8 g rn I a I g • me igam, 16d @, 16" o.c. 1/2"o AB's 0 6-0" 16d @ 16" o.c. 1/2" 0 ABs @ 6'-0" 16d @ 16" o.c. 1/2" 0 ABs @ 6'-0" 16d @ 16" o.c. 1/2" 0 A13s @ 6'-0" 16d § 16" o.c. 1/2" 0 ABs Q 6'_0" 16d @ 16" oc. 1/2" 0 AB's @ 6"-0" 16d @ 8" o.c. 1/2" 0 AB's @ 4'-0" NOTE: Where plywood is applied on both faces of a wall and nail spacing is less than 6" o.c, on either side, panel joint shall be offset to fall on different framing membars or framing shall be 3" nominal or thicker and nails on each side staggered. (Use 3x sill plate) Framing at adjoining panel edges shall be 3" nominal or wider and nails shall be straggered where 10d nails are spaced 3" o.c. or less. Revision design Office (714) 540-5177 Cell M4) 651-8946 2 5/19/05 Submittal to Plan Check E-mail — Janice6vereatiWeeign.net I � Beach Cltle% Oramp County Dwg- No, 4 of 6 1 Drawn by: 16d @ 4" o.c. 1/2" 0 AB's @ 4#-0" 16d @ 6" o.c. 1/2" 0 AB's @ 3'-0" 16d @ 4" o.c. 1/2" 0 AB's @ 2'-0" 16d @ 4" o.c. 1/2" 0 ABs @ 1 "-6" 16d @ 4" o.c. 5/8" 0 ABs @ 2'-0" staggered 16d @ 3" o.c. 5/8" 0 ABs @ 1 '-9'# staggered 16d @ 3" o.c. 5/8" 0 AlTs @ 1-3" staggered n p" 16, Z Z' Ir ,ake J ons d. !he , L Date: 51"19105 CONSTRUCTION DETAIL OWNER Herman Rodriguez 1114 W. 16 th STREET SANTA ANA, CALIFORNIA Water Ce�set : i.avatory ° Lavatory Balhltub ,` ` Shc7wer WIZti1�" bepth 22" Height VE]TA 11 E Revision Date Description MISC DETAILS OWNER Webalte — wwwversatiiedeeignmet Neeman.Rodriguez c) ice t�4} 540-5177 Celt M4) 65143948 2 5/19/05 Submittal to Plan Check 1114 W. 16 th STREET PLUMBING FIXTURES SCALE: E-mail — Janlce0vematilecieslgn.net Dwg. Date: No. S IJF 6 Drawn by; 5/19/05 SANTA ANA, CALIFORNIA Not To. Scale. Beach Cities, Orange Courrtr All UVIVIrULAINUE: KENIVENUAL (Page I of 3) CFI`-IR f),O 7-/ 6,/ Z&_fr'A L6 12� Daft ZCb�k Tel"Ine Plan t Wte or Computer} Climate Zone GENERAL Total Conditioned Floor Alva fe Average Ceiling Heilibi: I? __ III Conditioned Slab Fluor Am kll-% fe Building Type: — Single Family X—Addition (chcok one or morc) — Multi -Family _ Existmji.Flus-Addition front orictitation'. (N_.4,'South I East! West I All Orientations 1 1(4& *at or"C'Stom in &Wera r.. T-North end eisek, Nitmk>cr of Stories „_ Number of'Dwelling Floor Construction Type: RAD-U-NI BARMER- LM_Uimd in climate zoM 2, 4, 8-1 Required for this submitmIXYes --no BUIII ENVELOPE INSULATION Component Type Frarric Type wd - wood Sri - str-j Cavity Insulation R-Value Sheathing insulation R-Yalue Total X- Value' Assembly LT-Factor((attic, Location/Comments garage, typictit, &c.) Wall Wall Rat'r a _Rul��Or — Float �Ed ! __ - -1 Floor Snub c that =nt.tavlty,tZ•e,ahtc for the FENESTRATION FF.Itestririon I #/T Pas. orien- ration Area Ili) Yonestration 't)-Fattor SHGC Shadin Ate Overhangs,' Fins Front IV-049 A-1/14 Front U Left kcJcSii Wes Rear s"T op Ri lit Ril u. Sk Ii L1?M'X14b&i,-Jx loop-, January 5, 2001 MMDATORY MEASURES CHECKLIST: RESIDENTIAL (page i of 2) MF-1R Nato; Lowrise, residential buildings subject to the StanthadS MXI Contain these MastareS regardless Of the compliance approach use& (fears marked **b an asterisk (*) may W superseded by more stringent compliance requirements listed on The, Certificate of Compliance. 'Men this choddist is im",rated into the Permit dMolem% the features noted shelf be considered by all parties as numnium component perferprommspecificatiolas for file inundatory IneaSutes whether Thev arc sholxm elsewhere in the documents or on thischicklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESCRIPTION DESIGNER —Tr7 ENFORCEMENT Envelope Measures. § 150(b); Low fill insulation mastrustclurees labeled R-Vsluo. §150(c): murimium R-13 wan insulation in wood framed %saff's or aptivaliste U-Fwor in metal fisuru, WAI, (does nor applylo exteriamass walls). Slab into ludientolyptand form, §1 Fenestration Products, Exterior. Doom and Ipfihraliotttbxffination Controls t. DourseedvAmlow., hctaem eOntlidoaeal and unconditioned artaoss designed to limit air leakege. Z (tsitzrtfidd-AhAeatral) haw label with certified ti-Factor, ututifind Solar Beat Gain Coofficient (SHM, and institution tarlification. 3. Exterjordoom Sent -mik)w OR j-hus, and trouleations 44.11mat and Seated, I Sft);Vals0rh3omm mandatory to Climate 7oitcs 14 and 16 only, I*f)*, Special infiltration barrier installed toromrily with j 1st me= doesmissmo quality staaft& §150(c): Itisfallatian of Fireplsaes« r7ocutativc AppHancce and Gas L.P. 6w Outridnaor intake with damper and control u,. Fine damper Iced control allowed. Spam Conditioning, Water Heating and Plumbing System Measures: §1 t(I 13, HVAC ctuip. aat,,iSacr heaters, showedeld, and firicirstaffillod by the Commission. §1500): Reartinsir-&.'eoling leads calculated in socailaneewith ASIDI SMACNA -ACr-k. r zl5tiij)-, §1501 Pipe and tank insulation I - Surroge gas water litatenarated with an Energy Poster less than 0.58 muxtbe "terattly wrappodwith St greater) 1 Back-up tanks forselarsivam, unfiond storage ranks, or other huhroct hot water tanks have R-12 eatcond onodstion or P-16 combined iatemaHextcxnal insulation, 4. All buried or exposed piping hisatated in Ineroulathig sections other syAter systems, S. Cooling System piping below 55- F insulated. C Piping insulated betsevar henries sainee and, undi-t hot water funk. January 4, 2001 CERTIFICATE OF COWLIANCE: RESIDENTIAL � Lpage 3 2l' 3) CF-Unx L0,MPLLANCESTATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Pam I and 6 of the California Code of Regulations, and the administrativeregulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct Selling and TXVs (or Commission approved equivalent) requires installer testing and certification and field verification by an approved K-RS.rSter, Designer or Owner (Per Business and Professions Code) Doculittentationt Author Name: 44 Name: Jtj Titlemirm.. ThIeFirne fl4r,00 iz�- et Address: Address: Le1na,6 Telephone: Teb:jah —7 Lie. N: (days) fai Enforcement Agency Next= In 'I'itka .mil"ri Agency: Telephometz I L C An state (date) January _5, 2001 1LqWJA1kW L Al K' N, 11 L ISO= all CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 2 of 3) CF­1,R �4v Project TiII6 . Date ffV_AC SYSTEMS Note: Input hydraulic or tombawd hydmnic data under Water Hearing Systems, except Desiga Heating Toad, Distribution Heating Equipment Minimum Type and Duct or Heat Pump Type (finnuum, hett Efficiency Location piping Thermostat Configuration pumpcle.1 fAFUSorRVDjLUS!j attic, Cie.) R-Valuo Type-. (split -package) Cbrilingr4ulpment Minimum Duct Heat Pump TYPO (air conditioner. Efficiency Location Duct Thermostat Configuration .1-1 R_-p, mp_-thk) -(ssatt) (a.W�.. NQ P-Value T a a lit or ack-) AI,` SEA -LED DUCTS and TXVs far,Alternative Measures) 13 Scaled Ducts fatiamatannes) 0 TXvsorCommission approved equivalent; readily accessilie (clumnewines 2 and 0.15 _kV) (bnmntl testing =it =111ration isul BUS Ramr*r fiski vedficanion joir.hed) OR 0' Alternative to Scaled Ducts and TXVs (see Package C or D Alternative Package Features for Project Climate Zone) Climate Zone Window SffGC Window (;-Factor SEER Heating — _k e), 35- 6 - ril WATER HEATING SYSTEMS EneYi External Rated' Tank Factor or Tank Water Hearer Distribution Number Input (kW Capacity Recovety Standby' Insulation TV" in 5y--bOm -Rmfbfl f-ow Effi inn Los., M, R.Valua 1. sto.g. Water helots (rater inputs ofics, than m equal to 75,000 ituft), electric resisumev, and beat pump IKFI aergy razx1mvez" notes. water litamrs(rated input .fgreater than 7Saa0 BuI W Rated Input, Recovery pfricimeyand Standby I_ Foritstanneteons eas water heaters, list rated input and Ioovrty cffidetsciti. SPE(3AI, FEATURES (add tints sheets if nacessarvl. Package C and,D: TXVs or Commission approved equivalent, Scaled Ducts, Radiant Barriers (see installation requirements for radiant barriers in Section 8,13 of the 1999 Residential Manual), Package C: thermal muss (thermal mass type, covering, thickness, and description). January 5, 2001 MANDATORY MEASURES CHECKLIST: RESIDENTIAL (page 7 of 2) MF-IR Note: Lowisc residential buildings subject to the Standards "us! contain these measures regardless of the compliance approacl, used. Items marked with an asterisk (a) may be superseded by more aftingent compliance requarments listed an the Certificate of Compliance. Wrlien this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component Pcifinmencit specifications for the mandatory measures whether they are shoWn elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNFR ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: kolatinu I S01m), Ductsandfaras I - All ductsand plenum, jostsignal, Sealed and insubled tamest the guilthemmt oflbt 1998 CAC Ssxfiam 601, 603, 604, and Standard 6-3; ducts insulated to a minimum imaged level OfR-4.2 ortnelosed cativisly in conditioned spact. Openings "I be stated with [Haste, ", aerosol sealant, or other duct-chumne 4saso OWTUCCIS the SP004blortatuircmasals ofUL 181, UL ISIAor UL )SIB, to OW Openings gazter flum 1,14 inch, the combilsorion of"Wile Sad cithermsth or tape shall be used. Building carvida"I not be used for conveying conditioned air. Joins and Seems of duct Systems =it !heir eampotteou, shall nor be snalerd %vuh cloth back mbluir adhesive duct tapes unless such tape is used In Coulbiturtim, xith assialt, and 4mwbsnds. 2- Exhaust fall "coes have back draft or mumnatic dampers. 3- CW4vitY ventilating systems saving conditioned space have cidw automatic or, reedit, accessible, Ma-_ Ull —led ggWnv_ §114: PoaIliuldspItHisnoisyste-azdEquipment. I. SY-Ison is certified with 78% themud clficlI on.affsivitch, werther,"Fop "ating mmuctions, an eleetfi., msislarree hearing and nopilot light. 1 Syam is installed sailb: a. At least 36" oftilpebanyone firre, and heater for tonne Solar beating. It. Cover for outdoor pools oroludinurspas. 3- I'ad System has diesetioral hilm and a cimularjon, pump treat, switch_ 015- C-5 filed =it*) nuances. pan] heelers. spa insiders or household cooking appliances ban me conlinuousil burnt fttliglu. "out Non-rlecizioal cankiu a &sacas NAilh pilot < 150,Btuft) Luminaires fbr gesearej lighting in kitchens shall ban ho"a with an efficacy of4e t of greater for general lighting in Wettest, I fighting shall he —trolled by. switchOAS mash weetaiihIc lightinginersoll pareal at= to the kitchen, 050(42.: Room with it"wortirbakhtub huninsirewith lamps with an. effinacy, 01`40 hunelualWall or greater switched at The entrance to the meat orone eftbeahematives to this A-, nitpaant aaawod in ISoved.t LWA ELM &1010 *11oaki "IN N AR fAAK10 I I I'*j Am MA Revision MMA iffillmlm I ded gn Wal7raft — wwwworroaVieJesign.nat Office (714) 540-5177 0-01 M4) 661-8945 •Submiftal to Plan Check E-mail — JanicediversoUleAcefowlev DW9. No ftaoh ClVe% 011 County 6 of 6