HomeMy WebLinkAbout10150619.pdf241-811 1 A%'_1111 f. N aq .W-9 G.F.I./W.P. zo (E) HOSE BIBB t7i z } 0 ua G.F.I. / XP. (N) 6040 VIN SL @ W/CG. N W BATH # SHOW 30" min TUB ` *fl, NEW MASTERBDRM 126 8 H° N ! 2668 HC SH & POLE CL ! NAT GAS WALL HTR —SH 1 15 K.B.T.U. I & POLE \ SMOKE DETECTOR 110VS SH & POLE ro r — — X ao• Ic AcflEss \\~ j CL 1 (N)W! 00 SH & POLE �\ EXISTING WIN TO REMOVE AND PATCH EXISTING WIN TO REMOVE AND PATCH t MOK DETECTO 9 S EXISTING WALL TO REMOVE TO CREATE NEW OPPENING I/ EXISTING BDRM #4 1 tSTING WALL TO1E1 4OVETO CI SATE NEW OPPE 4IN � EXISTING BDRM # 3 SMOKE DETECTORays �> Fol 2668 HC SMOKE DETECTOR 9 VS MOKE DETECTOit Fol I SMOKE DETECTOR OVS 2668 HC 01 ❑Q z 5 N EXISTING BDRM # 2 SMOKE DETECTOR9 L26611 z W EXISTING BDRM# 1 72, z w 1617 TRINIDAD WAY 1' PLOT PLAN SC_ i� ISTING BATH # 2 0 Lu (0 o z SMOKE DETECTOR9VS ® EXIS NG BATH # 1 26688HHe 2868 SC x r .7L z EXISTING KIT EXISTING LIV. RM W(H (E) 6050 VIN SL I I I EXISTING DINE RM 3040 VIN SL EXISITING GARAGE 15070 GRGE DR 0 _V 1'0- 1 v FLOOR LA SC_ Y4" = �... GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 C.B.C. PLUMBING AND MECHANICAL CODES, THE C.E.C. AND LOCAL ORDINANCES. 2. VERIFY ALL DIMENSIONS, DO NOT SCALE DRAWINGS. 3. IT SHALL BE THE RESPONSABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON THE SITE PRIOR TO COMMENCING WORK AND IS TO NOTIFY THE OWNER AT ONCE UPON DISCOVER OF ANY OMISSIONS OR CONFLICT IN THE DRAWINGS. 4. ALL NAILING TO COMPLY WITH TABLE 23-11-B-1 G.B.C. 5. THE MANUFACTURED WINDOWS SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE NATIONAL FENESTRATION RATING COUNCIL (NFRC) AND SHOWING COMPLIANCE WITH THE ENERGY CALCULATIONS. S. LIGHT AND VENTILATION PER C.B.C. SECTION 1202. MINIMUM OF 15 C.F.M. OF OUTSIDE AIR PER OCCUPANT IS REQUIRED FOR VENTI,LATON. PLUMBING NOTES 7. ALL PLUMBING WALLS TO BE 2" x 6" 8. DOUBLE WALLS USED AS PLUMBING WALLS ARE TO BE A MINIMUM OF 9' WIDE AND NO "FLAT" STUDS PERMITTED. STAGGERED STUDS ARE ACCEPTABLE. 9. SMOOTH, HARD, NON ABSORBENT SURFACE IS PROVIDED TO A HEIGHT OF 70" ABOVE THE DRAIN INLET OF THE SHOWER OR TUB/SHOWER COMBINATION, MATERIALS SHALL BE OF A TYPE NOT ADVERSELY AFFECTED BY MOISTURE. 10. GLASS ENCLOSURE DOORS AND PANELS MUST BE LABELED CATEGORY 11, NET AREA OF SHOWER RECEPTOR SHALL BE NO LESS THAN 1024 SO. IN. OF FLOOR AREA, AND ENCOMPASS 30" DIAMETER CIRCLE 11. ALL WATER CLOSETSMARE LOCATED IN A CLEAR SPACE NOT LESS THAN 30" WIDTH AND HAVE 24" MIN. CLEARANCE IN FRONT OF THE STOOL. 12. FOR EXHAUST VENTILATION AIR, PROVIDE MECHANICAL FAN 5 AIR CHANGES PER HOUR. 13. WATER HEATER TO BE BRACED TO RESIST SEISMIC FORCES, PROVIDE TWO STRAPS (ONE STRAP AT TOP 1/3 OF THE TANK AND ONE STRAP AT BOTTOM 1/3 OF THE TANK). 14. WATER CLOSETS SHALL BE AN ULTRA LOW FLUSH TYPE WITH 1.6 GALLONS MAXIMUM PER FLUSH. 16. CONTROL VALVE FOR SHOWER OR TUB -SHOWER SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. 16. PROVIDE DEVICES TO ABSORB HIGH PRESSURES RESULTING FROM THE QUICK CLOSING OF THE QUICK -ACTING VALVES FROM THE WASHER AND DISHWASHER, ETC.. ELECTRIC NOTES 17, RECEPTACLE OUTLETS LOCATIONS WILL COMPLY WITH NEC Art 210-52 (a) 1120 AMP. CIRCUIT DEDICATED TO EACH BATHROOM" 18. ALL BEDROOM CIRCUITS REQUIRE ARC -FAULT PROTECTION. 19. GROUND -FAULT CIRCUIT INTERRUPTER (GFI) PROTECTION COMPLIES WITH NEC Art. 210-8: "ALL 126 volt SINGLE PHASE, 15 AND 20 AMPERES RECEPTACLES INSTALLED IN BATHROOMS, GARAGES, BASEMENTS, OUTDOORS, KITCHEN COUNTERS AND AT WET BAR SINKS, STRUCTURAL NOTES 20. THE CONTRACTOR SHALL PROVIDE ANY SHORING AND/OR BRACING TO THE EXISTING STRUCTURE WICH MAY BE REQUIRED DURING CONSTRUCTION. 21. PERMISSIBLE NOTCHING AND BORING OF JOISTS ARE TO BE SHOWN ON THE PLANS AND SHALL NOT EXCEED CBC SECTION 2320.8.3 ALLOWANCES. 22. NOTCHING OF EXTERIOR AND BEARING/NONBEARING WALLS SHALL NOT EXCEED 25% 1 40% RESPECTIVELY. BORED HOLES IN BEARING/NONSEARING WALLS SHALL NOT EXCEED 40°fo/60% RESPECTIVELY. IN NO CASE SHALL THE EDGE OF THE BORED HOLE NEARER THAN 6/8" TO THE EDGE OF THE STUD (2320.11.9 AND 2320.11.10) 23. HEADER AND TRIMMER DETAILS FOR DOORS AND WINDOWS ARE TO BE SHOWN WITH THE FULL LENGTH TRIMMERS, SPECIFYING THE SIZE OF THE HEADER AND TRIMMER (2320.11.6) 24. USE SIMPSON ST 6224 TO TIE-IN TO EXISTING TOP PLATES. 25.- ALL FRAMED BUILDINGS WICH ARE REQUIRED TO BE DESIGNED BY AN ENGINEER OR ARCHITECT MUST BE SIGNED PRIOR TO SUBMISSION INTO PLAN CHECK SHEET INDEX WALL LEGEND (E) WALLS TO REMAIN A-1= PLOT AND FLOOR PLAN (N) WALLS A-2= ELEVATIONS S-1= FOUNDATION AND FRAMING PLAN (E) WALLS TO REMOVE SD-1= STRUCTURAL DETAILS T-24= ENERGY CALCULATIONS - ELECTRIC LEGEND 1 ' DOTAL OF SHEETS 5 3 LIGHT REESES LIGHT FLUOR LIGHT tf ourLErllays 0 G.F.I. W.P. OUTLET 110 V GFI/ WP ' INTERRUPTOR i 2 ;0 3 ❑ SMOKE DEFECTOR t_ M�"' - 1 r "'^ '. 1 u1i U FAN S RIR CHANGES PER HOUR C& f . ,. ,. s ANALYSIS AREA EXISTING S.F.R. AND GARAGE NEW PROPOSED ROOM ADDITION TOTAL LOT RATIO LOT SIZE % LOT COVERAGE 1,505 S.F. 395 S.F. 1,900 S.F. 7,347 S.F. 26 % e 1� vo k Marco A. Ahumada 11111 Barclay Dr. Apt. 1 Phone 714 f 474-9162 Garden Grove, Ca 92641 !M W Nlow EID , AUG 2 3 200 5 D t� F , A.P.N. # 398 - 401 -11 Owner: Mr. Adalberto Duran Description of J•• Room f • Addition New i New drm i i 2nd. R.L. w1st R.L. CP 1st. R.L. N1 I T.O.P. 1441 � A XN' 1W x 24" FOUN�ESS� NORTH ELEVATION SClZxWFOUNDNENT. _ 3/4"W— 12-0 IV (TYP) SOUTH ELEVATION SC_ 1/41 I_WI ASPHALT SHINGLE TO MATCH (E) S.F 1st R.L. R T.O.P. W.L. 7 C3 F.L. MATCH (E) S.F.R. 7771 [T] E7 - - - - - - - - - - - - - -- - - - - - - T.O.P. W.L. I 01611 oil A ASPHALT SHINGLE TO MATCH (E) S.F —WOOD SIDING TO MATCH Uri (E) S.F.R. SC_ 1/47= 1'-0 M ONE ilEbT ELEVATION SC_ 1/47— 1 '-W I 1_0 -N-UM-1-01 E T-1 E "I 2"x 6" R.R. @ 16" o(c 12 4 2' X 4' TIES @ 48' 0(c OVER C.J. (2"x6"C.J.@16"ofcw/R-30INSUL (TYP) 7 D-1 2"x4"STUDS @16"o/c w/ R -13 INSUL (TYP) 1 34' T&G PLYWOOD 4'x 8"GIF 2'x 6"F.J. @ 16"de wl R-19 INSUL (TYP) 1st R.L. 2"X 8" RD. BD. — ASPHALT SHINGLE TO MATCH (E) S.F.R. 12 14 /'9-*"\ Yj" DRYWALL I NT. WALL & CEILING SC_ 1/4"M 1'-0 IV ATTIC VENT. CALC'S 395 S-Y.1150 = 2.64 Sq. Ft. x 144 = 380 Sq. In. REQUIRED 1.- G.I. Screened Eave Vent. 3 Holes 2" each (per block) = 9 Sq. In. At North Side =19 x 9 = 171 Sq. In. At East-West Side =12 x 2 x 9 = 216 Sq. In. TOTAL VENTILATION PROVIDED 387 Sq. In. UNDER FLOOR VENTILATION 395 Sq. Ft /150 = 2.64 Sq. Ft. x 144 = 380 Sq. Ft. REQUIRED 1211 x 6" FOUND. VENT = 72 Sq. In. Each 380172 = 6 Vents 6 Vents. x 72 = 432 Sq. In. PROVIDED TOTAL UNDER FLOOR VENTILATION PROVIDED = 432 Sq. In. MNNN��� rl Marco A. Ahumada 11111 Barclay Dr. Apt, 1 Phone 714 /470-9162 Garden Grove, Ca 92841 Description of Job: 395 Sq. Ft. Room Addition New MtrBdrm New Bath # 3 PROYECTBY SV Marco A. Ahumada 11111 Barclay Dr. Apt. 1 Phone 714 / 470-9162 Garden Grove, Ca 92841 >E zz A.P.N. # 398 Owner: Mr. Adalberto Duran Ph # 714 / 543 - 9347 Description of Jo� 395 Sq. Ft. Room Addition New MtrBdrm New Bath # 3 FRAMING ANCHOR TOP AND BOTTOM OF DOUBLE STUD OR POST \ FIRE BLOCKING AT CEILING LINE TO EXCEED 8'-W o/C 2- 2 x PLATES, SEE PLANS FOR SIZE AND REFERENCE TO SPLICES FOR HEADER SIZE, SEE PLAN / 2 x CRIPPLES AT 16" olo NOTES / PROVIDE SIMPSON A-34 FOR 2x 4 - %STUDS AND A-35 FOR 2x 6 STUDS, FOR NAILING SEE GENERAL EACH SIDE 1 STUD FOR INTERIOR WALLS, USE 2-2x JAMBS FOR 4x 10 AND 6 x 8 2 STUDS FOR EXTERIOR WALLS AND LARGER HEADERS UNLESS NOTED OTHERWISE � END POST AT PLYWOOD SHEAR -PANEL WHERE OCCURS w/ E.N. 13 TUDS SHOWN ARE FOR INDICATION ONLY, ACTUAL LOCATION O SUiT CONSTRUCTION REQUIREMENTS, MAX SPACING AT 16" o1c SHEAR WALL SCHEDULE 2001 C.B.0 SILL BOLTING MARK WALL TYPE SHEAR SHEAR ALLOWABLE ONESIDEBOTH SIDES SILL NAILING SHEAR OF WALL OF WALL 0 UPPER STORIES 7/8-STUCCO OVER PAPER BACKED LATH W/16 GA STAPLES AT 6"O.C. AT TOP & BOTTOM S, F SHEARAND No.1318, AUG. 2002) OR N FIE4 (I 9 180 PLF 5/8"055"O.C. 5/8"027 1/2-O.C,16d 0 8-O.C. MWALL AR 19 BELOWRT EDGEPORT (ICAO 3/8-PLYWD STRUCT 11 OR STD SHTG WITH 8d NAILS 0 6-O.C. AT EDGES & 12" O.C. FIELD 260 PLF 5/8"038"0.C. 5/8"019"O.C. 16d 0 6"O.C. fi\ TABLE 23-11-1-1 UBC NOTE 1, 9, 10 & 11 BELOW 3/8-PLYWD STRUCT 11 OR STD SHTG WITH 8d NAILS 0 4"O.C. AT EDGES & 12" O.C. FIELD 350 PLF 5/8"026"0.C. 5/8"013"o.C. 16d CAD 4"O.C. 0 (TABLE 23-11-1-1 UBC) NOTE 1, 6, 9, 10 & 11 BELOW 3/8"PLYWD STRUCT 11 OR STD SHTG WITH 8d NAILS 0 4"O.C. AT EDGES & 12" O.C. FIELD 380 PLF 5/8"026"a.C. 5/8*013"O.C. 16d 0 4"O.C. 11 (TABLE 23-11-1-1 UBC) NOTE 1, 3, 5, 6, 9, 10 & 11 BELOW 3/8" PLYWD STRUCT 11 OR STD SHTG WITH 8d NAILS 0 3" O,C. AT EDGES & 12" O.C. FIELD 490 PLF 5/8"02o"o.c. 5/8"01o"o.c. 16d 0 3 1/2"0.C. 2 (TABLE 23-11-1-1 UBC) NOTE 1, 3, 5, 6, 9, 10 & 11 BELOW 3/8" PLYWD STRUCT II OR STD SHTG WITH 8d NAILS ® 2" O.C. AT EDGES & 12" O.C. FIELD 610 PLF 5/8"016"O.C. 5/8"08"O.C. 1W 0 2 1/2"O.C. TABLE 23—II-1-1 UBC NOTE 1, 3, 5, 6, 9, 10 & 11 BELOW 1/2- STRUCT I PLYWD WITH 10d NAILS 0 2" O.C. AT EDGES & 12" O.C. FIELD 870 PLF 3/4"016"O.C. 3/4"08"O.C. N/A 14 OVER 3X STUDS TABLE 23—II-1-1 UBC NOTE 1, 3, 5, 6, 9, 10 & 11 BELOW HOWN 1. ALL EDGES OF PLYWOOD SHEARWALLS MUST BE 6. WHERE PLYWOOD IS APPLIED ON BOTH FACES OF A g, USE 2 1/2" x 2 1/2" x 3/16" PLATE BLOCKED WITH 2X SOLID BLOCKING FOR WALL TYPES WALL AND NAiL SPACING IS LESS THAN 6 "O.0 ON WASHERS. 9 & 10, AND 3X SOLID BLOCKING FOR WALL TYPES EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL 11, 12, 13, & 14. ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL 10, USE CDX. CC OR STD SHTG IN LIEU OF BE 3- INCHES NOMINAL OR THICKER & NAiLS ON STRUCT 11 PLYWOOD. ALL PLYWOOD SHALL BE 2. WHERE SHEAR WALL SHEATHING IS TO BE APPLIED EACH SIDE SHALL BE STAGGERED, DOUGLAS FIR. OTHER SPECIES MAY REQUIRE TO BOTH SIDES IF WALL, DOUBLE THE NUMBER OF CHANGES. BOLTS. (I.E. HALF THE O/C SPACING) 7. ALL CONTINUOUS EXTERIOR FOOTING TO HAVE 5/8" X 10" A.B.'S 0 48"O.C. UNLESS OTHERWISE 11. AT EXISTING FOOTINGS USE SIMPSON EPDXY 3. USE 3X PRESSURE TREATED DOUGLAS FIR NOTED ON PLANS. BOLTS PER SCHEDULED SiLL BOLTING, EMBEDED SILL PLATES AT FOUNDATION/FIRST FLOOR ONLY. 8", PER iCBO #25279 WITH SPECIAL INSPECTION. 8. ALL INTERIOR BEARING AND NON BEARING FOOTINGS TO HAVE 7/32" SHOT PINS AT 32" O.C. 4. PAPER BACKED SELF FURRING EXPANDED METAL & 48"O.C. RESPECTIVELY: I.E. HiLTI ICBO REPORT LATH WiTH ICBO APPROVAL No.2388, NOV 1995 OR RAMSET/REDHEAD iCBO 5. FRAMING AT ADJOINING PANEL EDGES SHALL BE REPORT No.1639, DEC 1995 3-INCH NOMINAL OR WIDER & NAILS SHALL BE STAGGERED. STRUCTURAL NOTES CONCRETE 3: GRADE JOIST, PURLINS 2" TO 4' WIDE, 6 & DEEPER No. 1 BEAMS, PURLINS OVER4"WIDE No.1 1: ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR WEIGHT HARD ROCK SUBPURLINS 2" TO4" WIDE, 6 & DEEPER No, 1 TYPE (160'CU FT) AGREGATES SHALL BE NATURAL SAND AND ROCK CONFORMING TO LEDGERS No. 2 STUDS 2" x 4" OR 3' x e STUDS ASTM C-33 WITH PROVEN SHRINK AGE CHARACTERISITCS OF LESS THAN 0.05 "% STUDS 2" x 6" No. 1 2- READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM POSTS 5' x 5" AND LARGER No. 1 SILLS, PLATES AND BLOCKING No. 2 C-94 PLACEMENT OF CONCRETE SHALL CONFORM TO ACI 301. 3: CEMENT FOR ALL CONCRETE SHALL BE PORTLAND CEMENT TYPE V OR BLOW ALKALL 4: SILLS AND PLATES IN CONTACT WITH CONCRETE OR MASONRY AND WITHIN 48, OF CONFORMING TOASTM C-150. GROUND, SHALL BE PRESSURE TRESTED DOUGLAS FIR (PTDF) SILLS SHALL BE BOLTED TO THE FOUNDATION WITH 5/8' DIAMETER x 10" LONG BOLTS AT 48' ON CENTER 12" 4: MINIMUM COMPRESSIVE STRENGHT OF CONCRETE AT AGE OF 26 DAYS FOR: MINIMUM FROM ENDS OR TWO BOLTS MINIMUM PER PIECE, iNLESS OTHERWISE NOTED. FOOTINGS 2,500 PSI 5: STUD WALLS ABUTING A CONCRETE OR MASONRY WALL, SHALL BE BOLTED TO THE SLAB OR GRADE 2,600 PSI WALL WiTH 6/8" ANCHOR BOLTS A7 24" 01C, SIDEWALKS 2,000 PSI B.- ALL NON BEARING STUD WALLS, SHALL BE 2" x STUDS AT 16' OIC WITH SM' GYP. BOARD 1 Joist to Sill or girder, toe nail 3-8d 6- MAXIMUM SLUMP SHALL NOT EXCEED 4'. EACH SIDE, UNLESS OTHERWISE NOTED. 2 Bridginggridging to joist, toe nail each end 2-8d 6, CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF 5 DAYS 7.- ALL STUD WALLS SHALL HAVE FULL HEIGHT 1" x 6" DIAGONAL LEFT -IN BRACES A7 ENDS AT INTERVALS NOT EXCEEDING 26 FEET 0!C UNLESS OTHERWISE NOTED ON $ 1 "X 6"25 mm X 152 mm subfloor or less to each 'Dist, face nail 2-$d AFTER PLACEMENT. ALTERNATIVE METODS WILL BE APPROVED IF SATISFACTORY PERFORMANCE CAN BE ASSURED, PLANS, BRACES SHALL COVER AMINIMUM OF SIX STUD SPACES. 4 Wider than 1" x 6" 25 mm x 152 mm subfloor to each joist, face nail 3-8d 7,- ALL REINFORCING STEEL ANCHOR BOLTS, DOWELLS AND OTHER INSERTS SHALL BE 8: COMMON NAiLS SHALL BE USED. 5 2" 51 m m subfloor to joist or girder, blind and face nail 2-16d SECURELY CONCRETE IS CLEANOUTSFSHALL E E iPROVIDED N THE FORMS BOTTOMEOF CONCRETE FORMS DFORDEQUATE PROPER 9.- FIRE BLOCKING 2" x 1 1/x " THICK, SHALL BE PLACED IN STUD WALLS AT CEILING AND 6 Sole plate to joist or blocking, typical face nail 16d @ 16" a/c CLEANOUT AND INSPECTION, FLOOR LEVELS AT EACH 10' HEIGHT OF STUDS AND BETWEEN STAIR STRINGERS AT Sole to 'Dist or blocking, at braced wall 16" 3-16d SUPPORTS. plate panels per 8: VIBRATION OF CONCRETE SHALL BE IN ACCORDANCE WITH THE GENERAL PROVISIONS 7 TO late to Stud, end nail 2-16d OUTLINED INPORTLANDCEMENT ASSOCIATION SPECIFICATIONS ST-26. 10- JOISTS SHALL BE BNLOCKED AT SUPPORTS AND BRIDGED OR BLOCKED AT INTERVALS OF8'WHEREJOISTS ARE 2"x12"OR DEEPER. 8 Stud to sole plate 4-8d, TOE NAIL, or 2-16d, END NAIL 9: EXPOSED CORNERS COLUMNS, BEAMS, WALLS, ETC, SHALL BE FORMED WITH'/e " CHAMFERS UNLESS DETAILED OTHERWISE. II. MAXIMUM UNSUPPORTE HEIGHT FOR NON -BEARING PARTITION SHALL BE: 9 Double studs, face nail 16d 24" o/c 2" x4" @ 16"O/C UP TO 14'-0" 10 Doubled top (?fates, typical face nail 16d 16" o/c o/c 10: CONCRETE CONTRACTOR SHALL BE SUBMIT PROPOSED CONCRETE DESIGN MIX TO THE ARCHITECT AND ENGINEER OF RECORD, PRIOR TO STARTING THE WORK. 2" x 6" @ 16" 01C UP TO 20'-0" 2"x8' @ 16" 01C UP TO 26'-0" Doubled top plates, lae splice 8-16d 1 I.- NOWATER SHALL BE ADDED TO CONCRETE WITH TEMPERATURE IN EXCESS OF 95 ° F. 12.- PROVIDE DOUBLE JOISTS UNDER PARALLEL BEARING PARTITION WALLS, 11 Blocking between joists or rafters to top plate, toenail 3-8d 12: WIRE MESH LAP (END & SiDE) MALL BE ONE FULL MESH -2 13.- BOLTS HOLES IN WOOD MEMBERS SHALL BE A MINIMUM 1/32' AND A MAXIMUM 1/16" 12 Rim joist to top plate, toenail 8d 6" o/c LARGER THAN THE BOLT DIAMETER. 13 To plates, laps and Intersections, face nail 2-16d PLYWOOD REINFORCING STEEL 14 Continuous header, two pieces 16d 9, 16" o/c along each edge 1 : PLYWOOD SHEETS SHALL BE COX CONFORMING TO PS 1-96 AND SHALL BE STAMPED WITH THE DRPA GRADE OF THE AMERICAN PLYWOOD ASSOCIATION, UNLESS NOTED 1.- REINFORCING STEEL SHALL E INTERMEDIATE GRADE DEFORMED BEARS AS 15 Ceiling joists to late' toenail ' 3-8d OTHERWISE ON THE PLANS. FOLLOWS: 16 Continuous header t0 stud, toenail 4-8d FOOTING, SLAB ON GRADE, MASONRY AND BENT DOWELLS, TIES: 2: EACH SHEET SHALL HAVE AMINIMUM AREA OF 8 SO. FT. WITH A MINIMUM DIMENSION # 3 BAR AND SMALLER ASTM A- 615 GRADE 40 17 Ceiling joists, laps over partitions, face nail 3-16d OF 2 FEET. #4 BAR AND LARGER_ ASTM A- 616 GRADE 60 18 ,Ceiling oists t0 parallel rafters, face nail 3-16d 3: SEE FRAMING PLAN FOR DIAPHRAGM NAILING SHEDULE, NAILING SHALL BE INSPECTED 2: DEFORMATION OF REINFORCING SHALL BE IN ACCORDANCE WITH ASTM A 305 AND 19 Rafters to late, toenail 3-$d AND APPROVED BEFORE COVERING, BENDING IN ACCORDANCE WITH ACI-WS-95. 20 1" 25 m m brace to each stud and plate, face nail 2-8d FOUNDATION NOTES 3.- MINIMUM CONCRETE COVER OVER REINFORCING REBAR FOR: (EXCEPT AS NOTED OTHERWISE) 21 1" X 8„ 25 mm X 203 mm sheating or less to each bearin , face nail 2-8d I. FOUNDATION HAS BEEN DESIGNED ASSUMING MINIMUM ALLOWABLE DOIL BEARING NOT EXPOSED 7O WEATHER OR EARTH 1" EXPOSED TO WEATHER 1 f: " 22 Wider than 1" x 6" (25 mm x 152 mm) sheating to each bearing, face n; 3-8d PRESSURE PER 2001 UNIFORM BUILDING CODE SHALL BE AS FOLLOWS: EXPOSER 28 Built-upcorner studs 16d 24" o/c CONTINUOUS FOOTING 1,000 P.S.F. PILASTER, & C COLUMN TiES I 'X " BEAM BEAM FORMED FOOTING AND WALL EXPOSED TO EARTH 2" 20d @ 32" O/c topand bottom and ISOLATED FOOTING i,000 P.S.F. UNIFORMED FOOTING AND WALL EXPOSED TO EARTH 3' SLAB ONGRADE 2- 24 Built-up girder and beams staggered 2-20d @ ends and @ each splice 2- ALL FOOTINGS SHALL BE FOUNDED ON OR BELOW FIRM UNDISTURBED NATURAL SOIL OR APPROVED COMPACTED FILL AND ADJACENT FINISH GRADE UNLESS NOTED 4.- SPLICE IN CONCRETE: OTHERWISE. MINIMUM OF 36 BAR DIAMETER OR 17 WiCHEVER IS GREATER. 25 2" blanks 2-16d @ EACH BEARING 3: ALL FOOTING SHALL BE CENTERED ON PLASTER AND/OR WALL AND COLUMN UNLESS 5: WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND 1-82. OTHERWISE NOTED. 4: FINISH FLOOR (F.F) EXCAVATION SHALL BE AS NOTED ON GRADING PLANS. 6- ALL DETAILING OF REINFORCING SHALL CONFORM TO THE REQUIREMENTS OF ACI 318- 95 5.- THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF ANY ADJACENT 7. ALL REINFORCING STEEL, DOWELS, ANCHOR BOLTS, INSERTS, ETC, SHALL BE SECURED PROPERTY STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, PLACE PRIOR TO PLACING ANY CONCRETE OR GROUT. STATE AND LOCAL SAFETY ORDINANCES. 8.- ALL REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM AV615 6- ALL FOOTINGS SHALL BE FORMED TO MEET SIZES INDICATED ON DRAWINGS, DETAILS GRADE 60. AND/OR SHEDULES, 9: ALL REINFORCING BAR BENDS SHALL BE MADE COLD. 7: ALL FOOTINGS AND PIERS SHALL BE CENTERED UNDER THE BUILDING COLUMNS 10- ALL REINFORCING BARS SHALL BE FREE FROM GREASE, RUST, MILL SCALE OR ANY (U,N.O.) OTHER FOREIGN MATERIAL WISH MAY AFFECT THE BARS ABILITY TO BOND TO THE 8: ALL EXISTING UTILITIES THAT INTERFERE WITH THE STRUCTURAL FOUNDATIONS MORTAR. SHALL BE REMOVED AND RELOCATED. It.- REINFORCEMENT THAT IS PARTIALLY EMBEDED IN CONCRETE SHALL NOT BE FIELD 9- ALL PIPES, DUCTS AND CONDUITS WITHIN THE SPHERE OF INFLUENCE OF THE BENT EXCEPT AS SPECIFICALLY DETAILED IN THESE DRAWINGS OR WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER OF RECORD. FOOTING (THE PRESSURE ZONE, EXTENDING BELOW THE FOOTING, BASED ON A 2 HORIZONTAL TO 1 VERTICAL SLOPE) :HALL BE SLEEVED THROUGH CONCRETE CAST -IN- 12.-ALL REINFORCING STEEL SHALL BE PROVIDED AT ALL POUR JOINTS ON THE PLACE AT THE FOUNDATION POUR. DRAWINGS, WHERE LAP AND/OR SPLICE LOCATIONS ARE NOT SPECIFICALLY iNIDICATED, 10, FOUNDATIONMAY BE SUBJECT 10- FOUNDATION MAY BE SUBJECT TO TRUCTURAL REVISION IN THE FIELD DUE THE PROVIDE CLASS'C' SPLICE PER SCHEDULE. ALL SPLICE LOCATIONS SHALL BE CLEARLY SHOWN ON SHOP DRAWINGS AND APPROVED BY ENGINEER OF RECORD BEFORE CONDITIONS, FABRICATION, LUMBER 13- PLACING TOLERANCES AND BAR SUPPORTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR REINFORCING CONCRETE CONSTRUCTION BY WCRSi. 1: ALL LUMBER SHALL BE GRADE MARKED DOUGLAS FIR LARCH CONFORMING TO DIVISION 23 (2001 C.B.C). 14: CLEARANCE BETWEEN PARALLEL BARS IN A LAYER SHALL NOT BE LESS THAN i" NOR 1 BAR DIA NOR 1x MAX AGRAGATE SIZE. 2: RAFTER, BEAMS, PURLINS SHALL BE DOUGLAS FIR NO. UNLESS OTHERWISE NOTED. BARS IN SECOND LAYER SHALL BE DIRECTLY ABOVE BARS IN FIRST LAYER, MIN DISTANCE BETWEEN LAYERS 1". A - 35 @ 16" o/c (Alt) Y" Drywall Int. wall & Ceiling PLYWOOD PER ^ ` ffff""a Sof �0, SECTION X @ HIP 2" x RAFTER PER PLAN O PLAN 10 m Roofing material o/ 15# Felt & Y2" C.D.X., 24%o Plywood 2" x Roof Rafters per plan 3 Holes 2" each G.I. Screen'd Eave Vent. 2" x Ceiling Joists per plan w/ R -30 insul. 2" x Blocking w/ 3-16d per block & 5-16d @ Rafter lie 2- 2" x4" Double Top Plate 2" x 4" Studs @ 16" o/c w/ R-13 Insul (Exterior) Exterior Finish ««« - M I.��dIY�7�d:i5T_Rl 14 '16d T.N. PER SCHED BM. PER PLAN SECTION X @ VALLEY ---..____..__HIP SM OR VALLEY BM. PER PLAN EXTERIOR FINISH --- 2" x 4" SOLE PLATE WEEP SCREED 2" x BLOCKING — A-35 @ 16" o/c 2" min. OF STEM^' I.� ! — ----- 2 -16d T.N. @ 2" x 4" RAFTER 3 -16d T.N. Q 2" x 6" RAFTER 4 -16d T.N. @ 2" x W RAFTER 2' x RAFTER PER PLAN 5 -16d T.N. 0 2" X IM RAFTER 2 2 X RIDGE BOARD ST 2115 @ 4W o!c B.N. IN LIEU OF 2" x 4" TIES PLYWD ROOF SHTG PER PLAN 2" x 4" TIES @ 48"o!c OVER C.J. R.R, PER PLAN 3 -16d (M) +{* C.J./ TIE PER PLAN wl R INSUL Plywood Shaatinn mr nian 2 x Rafter "California" Framed 'w/16d@6'01C NOTE: in Lieu of 2 x Blocking nail 2 x Shaped w/ 2-16d ea Rafter PLYWOOD SHEATING PER . . I 2" x BLOCKING @ 48" olc FIRSTBAYONLY 2" x 4" BLOCKING wl 16d @ 8" o1C or A-35 @ 24" o(c SHEAR WALL @ CRIPPLE WALL WALL FINISH PER PLAN -� 2" x SHAPED w/ 16d @ 16" o/c__ I� (N) 2 x 6 C.J. (E) 2 x BL.K'G A-35 @ 24"t CALIFORNIAE CONT @ .• 1 whwo —'; e. #. . �r I I% 6" min. 7° =11I=1 I 6" 12" One Story 15" Two Story 6" 2" x 4" STUDS @ 16" o1c wl R-13 INSUL (EXTERIOR) V4" T & G PLYWOOD OR BLOCKED 2" x 6" F.J. @ 16" o/c w/ R-19 INSUL 2" x 4" P. MUDSILL w/ Ve DIA x 10' L.1 A.B. & MUDSCREED w/ 2" x 2" x N16" WASHERS 18" min. @ 4W o/c 12" One 15" Two I 1 _ 12" One StO — -- # 4 REBAR TOP & BOT I & Two Story FULL DEPTH BLOCKING 2" x 6" FLOOR JOIST @ 16" o%w/ R-19 INSUL a" T & G. PLYWOOD CXXX� X.%`�C;t.X.XJ P.B. 44 4" x 8" GIRDER 18" min. 1, 4" x 4" POST (AS REQUIRED) 49"-,k----- ``- 6" x 6" x 2" P.T. BLOCK CONC PIER 18" Sq. SCHEDULE 3112" TYPE SSTB # SSTB # CAPACITYWI 1-POUR 2-POUF 4 x 4 min. Poet per plan 2" x Stud FilterPHD2- 16 20 3,610 (4 x min) SDS3 HD2A 16 20 2 775 Fasteners per mand HTT16 16 20 3AW HD6A 16 20 4,010 Simp Hoidown PHD5A- per plan (PHD g own) SDS3 20 24 4,600 HTT22 24 6,175 PHD6- SDS3 28 34 61860 HD6A 28 34 6,105 2x, 2 - b( HD8A 28 34 7460 Le Simpson or 3 x per plan HD10A 28 34 9,640 Min SSTB HDCXI- 3" Per Schedule SDS3 28 34 8,326 Note: Concret Stem Walls shall be. Note: For Raised Foundation use SSTB for two pour system 6" min widht for V diam Anchors and extend bolt beyond sill plate above flax sheeting or use 8" min widht far %" diam Anchors Simp. CNW Coupler for Bolt Extension. 3 ) 8" min for conc block PHD or HD PER PLAN & SIMPSON CATALOG 4 x 4 POST MIN DRILL HOLES Y16" LARGER EXIST OR NEW SiLL THAN BOLT DIAM. m A rc 0 EXISTING FOOTING THREADED ROD w/ EPDXY I.C.B.O. # 5279 CITY OF L.A. R.R. # 25279 w/ SPECIAL INSPECTION Note;' SCHEDULE TYPE "D" THIRD ROD (diam) _ Allow Tensile Load (See Note 1) PHD2- SDS3 12" 3,610 " s" >75 HTTIB 1 a ,48 HD5A 12" " 4,010 PHD5A SDS3 12" a/" 4,685 HTT22 12" /" 5,250 SDS3 15" 1" 5,860 HD6A 15" a" 5,105 HD8A 15" /6" 7,460 HD10A 15" a" 9,540 HM SDS3 15" %" 8,325 1: Concrete= f c=2,000 P.S.I. min. 2. For Raised Floor, use Longer Bolts to extend above Floor sheating 6" 18" min. Existing Slab New Slab * NO Special inspection is required for epoxy in this aplication Drill %a" 4 diam hale fill w/ epoxy # 4 Rebar Dowels @ 187 o% grout & insert dowell alternate; use Yz" redheads & thrd'd rod Reber Doweiis same size & spacing as footings Drill Slant holes ,116" over dia of bar, ExISt'g New Raised Floor fill w/ epoxy grou 6" 24" min _.-..-.-.-.-_-.-._-........._ --- .-._ V LC.B.O. # 5279, I.C.C. REPORT 5279 2" x 4" SOLE PLATE 2" x F.J. PER PLAN NOTES: LOADS MAY NOT BEiNCREASED FOR SHORT TERM LOADING A MUDSILL ON TOP OF GH IS REQUIRED TO ACHIEVE THE TABLE LOADS GiRDER PER PLAN 12" min / GIRDER HOLDOWN PER PLOD * N.E.R. 443, L.A. R.R. 25149 V � �-1 l 1=! j l-1 I=i1 111 } 11=11 l— 11=111= =�lA 1 (E) OR NEW 2" x STUDS WHERE OCCURS 2" x BLOCKING / , (E) 2" x F.J. WHERE OCCURS ' 2" x 4" P.�. MUDSILL Wf %" DIA x 10" L. A.B. & MUDSCREED w/ 2" x 2" x 3ta" WASHERS 18" min. @ 48" O/c r Owner: Adalberto Duran P 1 I • / Description of is 395 s o Addition New MtrBdrm New Bath Duran`s Addition, Aug, 41 2045 DOW 161.7 Trinidad ItVa Santa ,Ana; Ga 927Q1 y f Marco A. Ahumada 11111 Barclay Dr. Apt. 1 Phone 714 1470-9162 Garden Grove, Ca 92841 U Adalberto Duran '� " f f • f f f Sq. Ft. Room Addition New MtrBdrm New Bath # 3