Loading...
HomeMy WebLinkAbout10150579.pdfNOTES ff!�51_IN6 DWELLING: Eh( 77IN6 G/iPAOff r 9'POPO5E0 ADOtrION: rOrAL B84 -150, I~r 400 �0, FT-, 148150. FF. Z,O�Z Pk`OPO_'5EIV ONE �rOPY A0017710N- eAr5ffD FI-00? tPFN 0!3-Oi2-Z 'Lol-ApEll : !:50 x 0�4 - 6,100 50, Fr, TOrlil.- PuILOINC-. ApitA 2,0_�52 LOr c0✓fn�AG � 10101V-.f 6,100 - 507<�5Oy Ok OGGurANGY6910up TYPE 0,F GON�TPuGr/0N APPLICAPlE GODE� e_15/u/ VN C00 2001 DOOR SCHEDULE i6'-8- : DOUBLE DOORS '. i x t . DOUBLE ii!' •u 0 !' ii*` i DOOR W/PRIVACY LOCK I I WINDOW i i SLIDER • i i "H SLIDER t i , i -0-W SLIDER K REFERS TO NEW WALL (SHOWN SHADED) REFERS TO EXISTING WALL TO REMAIN EXISTING WALLS TO BE REMOVED NOTE: 1.- ALL NEW EXTERIOR WALLS TO HAVE R-13 BATT INSUL. 2.- NEW RAISED FLOOR TO HAVE R-19 BATT INSUL. 3.- NEW RAISED FLOOR TO HAVE R-19 BATT INSUL. Note: 1.- SILL HEIGHTS ARE NOT MORE THAN 44" ABOVE THE FLOOR 2.- ALL NEW GLAZING TO BE DUAL -PANE w/ U = 0.75 MAX. FENESTRATION SHOC = 0.40 MAX. GENERAL NOTES: 1. ALL FABRICATION TO BE PERFORMED BY A LICENSED FABRICATOR. 2. 2x4 STUDS MINIMUM, 3. KITCHEN & BATHROOM TO HAVE FLUORESCENT GENERAL LIGHTING SWITCH TO BE THE FIRST NEAR THE DOOR. 4. WATER HEATER TO BE STRAPPED AT TOP AND BOTTOM 1 A WITH 1 1/2x 16ga STRAP w/ 3/8"Di0x3" LAG BOLT EA. EN A3 5. WALL COVERING SHALL BE CEMENT PLASTER, TILES OR APPROVED EQUAL TO 70 INCHES ABOVE DRAIN AT SHOWER. MATERIALS OTHER THAN STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANCE. GLASS ENCLOSURE DOORS AND PANEL MUST BE LABELED CATEGORY 11. 6. CEILING HEIGHT FOR LAUNDRY ROOM & BATHROOM IS MIN. 7'-0" 7. NEW WATER CLOSET TO BE WATER -SAVING TYPE WITH 1.6 GALLON PER FLUSH LABELED CATEGORY 11. FLOOR PLAN NOTES [11 TOILET 2. LAV 3. SHELF & POLE 4. HOT TUB SELECT BY OWNER. 5. WASHER & DRYER SELECTED BY OWNER 12A 6. NEW WATER HEATER LOCATION W/SEISMIC STRA A3 7. CERAMIC TILE SHOWER W/ 30" INSIDE CLEAR 8. HEATER SELECTED BY OWNER rl FAU LOCATION IN ATTIC. SEE DETA 9. 24" CLEAR IN FRONT OF TOILET A3 10. FINISH GRADE 11. ROOF SEE ROOF PLAN 12. RIDGE 13. G.1 CRICKET AT ROOF 14. NICHE 15. METAL FLUE TRANSITION TO ROOF 16. STUCCO SOFFIT OVER ENTRY. SEE EXTERIOR ELEVATION. 17. 22x30 ATTIC ACCESS WITH 30" HEADROOM. WALL LEGAND (N) REPRESENTS NEW (E) REPRESENTS EXISTING CLR. REPRESENTS CLEAR sn HARD WIRE SMOKE DETECTORS WITH A BATTERY BACK UP. SMOKE DETECTORS BATTERY OPERATED ON EXISTING ROOMS -('- REPRESENTS LIGHT FIXTURE :9 REPRESENTS 120V DUPLEX WALL OUTLET + REPRESENTS LIGHT SWITCH 0 INDICATES 2x6 PLUMING WALL rOP GffNfP/i N07-f-'5 AND L_,ff E1\10 .'5ff _-5fTfT A-1 � NOTE: ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLT, SINGLE-PHASE, 15 AND LLJ 20 AMP RECEPTACLE OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT I� INTERRUPTER. GENERAL NOTES: 2. KITCHEN AND BATHROOMS TO HAVE FLUORESCENT GENERAL LIGHTING. SWITCH TO BE THE FIRST NEAR THE DOOR. 3. WATER HEATER TO BE STRAPPED AT TOP AND BOTTOM WITH 1 1/2x 169c STRAP w/ 3/8"DTOx3' LAG BOLT EACH END. SEE LOWER LEVEL ELECTRICAL PLAN. 4. WALL COVERING SHALL BE CEMENT PLASTER, TILES OR APPROVED EQUAL TO 70 INCHES ABOVE DRAIN AT SHOWER. MATERIALS OTHER THAN STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANCE. GLASS ENCLOSURE DOORS AND PANEL MUST BE LABELED CATEGORY 11. 5. CEILING HEIGHT FOR LAUNDRY ROOM do BATHROOM IS MIN. 7'-O" 6. NEW WATER CLOSET TO BE WATER -SAVING TYPE WITH 1.6 GALLON PER FLUSH (© LABELED CATEGORY 11. I 1.- LUMBER: a) USE DOUG L AS FIR CONSTRUCTION GRADE #1 FOR 6x AND LARGER. C7 N D.F. GRADE 02 FOR ALL 4x AND SMALLER. I b) ALL LUMBER IN CONTACT WITH CONCRETE 'SHALL BE PRESSURE TREATED OR WOOD RESISTANT TO DECAY. c) 2x8 ROOF RAFTERS WITH R-30 RIGID INSULATION LO AND RIDGE VENTS PROVIDED GENERAL. FRAWNG NOTES 1. REFER TO SHEET SN-1 FOR GENERAL NOTES AND TYPICAL DETAILS. 2. ALL STUD WALLS SHALL BE 2 x 4 STUDS AT 16" O.C. HEIGHT SHALL NOT EXCEED i0'-0', UNLESS OTHERWISE NOTED. 3. ROOF SHEATHING SHALL BE 1/2' PLYWOOD, PANEL INDEX 24/0 WITH ad NAILS AT 6" O.C. BOUNDARY•. B" O.C. EDGES; AND 12" O.C. FIELD. 4. FLOOR SHEATHING SHALL BE 3/4" (MIN.) THICK PLYWOOD TW% PANEL LL Z INDEX 40/20 WITH 8d NAILS AT a O.C. BOUNDARY, 6" O.C. EDGES; AND 10" O.C. FIELD. 5. PLYWOOD SHEATHING SHALL BE PLACED WITH FACE GRAIN PERPENDICULAR TO JOISTS OR RAFTERS. LL 6. PROVIDE DOUBLE JOISTS UNDER PARTITIONS RUNNING PARALLEL TO JOISTS O. AND AROUND OPENINGS. a 0. 7. PROVIDE SOLID BLOCKING BETWEEN JOISTS UNDER WALLS RUNNING PERPENDICULAR TO JOISTS. B. PROVIDE FURRING TO ALIGN GYPSUM SHEATHED NON -SHEAR WALLS WITH PLYWOOD SHEATHED SHEAR WALLS, WHERE OCCURS. 9. PROVIDE 1 x 6 DIAGONAL LET -IN BRACING AT APPROXIMATELY 45 DEGREE AT EVERY 25'-0' MAXIMUM, AT STUD WALLS WHICH ARE NOT SHEATHED. 10. TOP PLATES OF ALL STUD WALLS SHALL. BE TWO PIECES OF THE SAME SIZE AS THE STUDS. SPLICES SHALL BE LAPPED V-0' MINIMUM WITH 10-16d AT EACH SIDE OF THE SPLICE, 11. STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, ETC. UNLESS SPECIFICALLY DETAILED. 12. ALL HARDWARE SHALL BE AS MANUFACTURED BY SIMPSON STRONG -TIE OR EQUAL. 13. D.S. INDICATES DRAG STRUT. PROVIDE BOUNDARY NAILING ALONG THE ENTIRE LENGTH OF THE STRUT. 14. ( INDICATES DRAG STRUT FORCE. ROOF TRUSS MANUFACTURER SHALL „ f DESIGN THE D.S. TRUSS FOR THE GIVEN LATERAL LOAD APPLIED AT TOP CHORD. I& ALL FLOOR JOISTS SHAD.. BE 2 x 14 AT 16' O.C. TYPICAL, UNLESS �" OTHERWISE NOTED. AS AN ALTERNATE TO LUMBER. JOIST MAY BE MANUFACTURED BY TRUSS -JOIST MACMILLAN OR EQUAL. 16. TRUSS JOISTS MANUFACTURER SHALL SUBMIT STRUCTURAL CALCULATIONS, DETAILS, AND SPECIFICATIONS FOR APPROVAL BY THE STRUCTURAL ENGINEER AND THE BUILDING DEPARTMENT PRIOR TO FABRICATION AND INSTALLATION. a- 17. FLOOR FRAMING DETAILS SHOW LUMBER FLOOR JOISTS. TRUSS JOISTS DETAILS SHALL BE SIMILAR t .. 18 <10> INDICATES SHEAR WALL. REFER TO SHEAR WALL SCHEDULE NOM 1. USE 3X SILL PLATE FOR ALL WALLS WHERE ALLOWVBE SHEAR VALUES EXCEED 350 W. L USE 3X SILL PLATE AND UPPER TOP PLATE WHEN PLYWOOD IS APPLIED ON WIH SIDES OF THE WALL 3. AT ALL ADJOINING PLYWOOD EDGES, USE 3X STUDS & BLOCKPIOL 4. PROVIDE 1/2° EDGE DISTANCE FOR PLYWOOD BOUNDARY HALING. 5. SQUARE WASHERS SHALL BE USED WIN ALL ANCHOR DOLTS. W BOLTS - L5 x LAI x 1/4 3/4" BOLTS - 175 x 175 x 5/16 7/8' SITS - 3 x 3 x 3/8 L ALL SHEAR WALL NAILING SHALL UTILIZE CM0C I NAILS 7. PLYWOOD SHALL BE C-D. O-C. SHEAIHII A PLYWOOD PANEL 9DN0 OR ANY OTHER GRADE S OMAM N U,= STANDARD 2342 OR 23-A 8. ALL PLYWOOD SHAD. BE FOUl -PLY IMMMUM. & MAXIMUM ALLOWABLE SMEAR FOR THREE-PLY PLYWOLXIIS 200 PLF 10. • DESI M70 WALL SHEAVING IS APPLED 10 801H SIDES OF 1HE WALL 11. EN DESIONATLS EDGE NALUNO. 12. FN DESIGNATM FIELD HAIUN0. I& OC DESIDNATES ON CENTER. 14, LAG DESIONAlE3 LAG BOLT WIN 8 MNW A PENETRATION INTO MAN VOWL 11 AS DESIGNATES ANCHOR BOLTS I& C/ DESIGNATES OVER. APPLICABLE CODES: 2001 CALIFORNIA BUILDING CODE 2001 CALIFORNIA MECHANICAL CODE 2001 CALIFORNIA PLUMBING CODE 2001 CALIFORNIA ELECTRICAL CODE SANTA ANA MUNICIPAL CODE 2001 CALIFORNIA ENERGY CODE INSTALL A 5/8'THK. TYPE °X• G.B. AT INTERIOR WALL OF GARAGE FROM FLOOR TO ROOF. C� f7�iscild- b t RUSSEL ST. v u n E \, SITE PLAN SCALE: 1 /8"=1'-0" An, o 11RATAE'NWI A A. A A A A A A A A A A A T Q 00 /1 0ry Q • a- Ls! F-00 Q N O 00 t: 0 0 cy U Z r a f'- t.LJ J � J LU GY tZ w el! 13- Gi1 Z •• 0 w< • i r Z coz L) 0vi -� • ,, , 0 Q 0 N 0 I 04 CV it r am m Q w 0 SHEET 2 9-14"vl 4" 10" SYM TO EXIST. FIN. FLR. FIN .' FLR.' I 1 1001*1 MOV 0 IWAII 1 0 11 ilk Em IAm Al IFAIN N M m WN MINIM 7/8- THCK. CEMENT PLA PLASTER MIX: 1:4FOR SCRATCH COAT & 1: 5 FOR BROWN COAT BY VOLUME, CEMENT TO TYP. �0� 14 of x6" UNDER—FLOO?i VENTS. 10—TOTAL COVERED WITH WIRE MESH 1/4" OPNG. 5/8"0 x 10" @ 48" O.C. MAX.-12 FROM CORNERS & SPLICE ENDS-7" MIN. EMBED. TYP. W/2 1/2"SQ. x 1/4" WASHER PLATE UNDER EA. NUT. NUTS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL N FRAMING in 2x FASCIA SYM TO (E) 10" SYM. TO EXIST. 2x4 STFI)* 0 16"o/c u.n.o. 8A A3 11'_0" z 0 9 cj U- 00 X SOUTH ELEVATION 2x RIDGE BM per plan 2x Roof Rafters 12 per plan 5 1 ROOF SLOPE 2x Ceiiling Joist per plan 34•—D" 11'_6" ___w q - X" cn T 0 �ql m \q V)* �0 0 73 R ' N cr. 0 0 C3 _j LL 00 x " . 0 a c*4 0 R30-Insulation - R13 R19—Insulation TYP. W., � 30"X30" OPENING IDERNEATH T"YP.2-LOC. L 16'—�, 28*-1* A3)VA9v\\' 2x ROOF TIES 0 4'-0"o/c ca R E V I S 1 0 N S A A A A A A A A A A A A A co (0 > U] 0 ©c uj CL ATTIC VENT CALCULATION :D ATTIC VENT REQUIRED: W .< 748/150 = 5.0 SQ. FT. 00 c*4 ATTIC VENT PROVIDED: 0 00 0) 2-14"x14" = 1.2 x1.2x2= 2.8 SQ. IT. W 0 0 CN THE REMAIN WILL BE CD PROVIDED BY EAVE VENTS HOLES 2" DIAM.1 Li z 0 COVERED W/1/4" CORROSSION RESISTANT METAL MESH COVERING w 3—HOLES BETWEEN RAFTERS MIN. m ui LA_ w m a. 0- SECTION 1 4 z1� UNDER -FLOOR VENT CALCULATION UNDER FLOOR VENT REQUIRED: CL 15 748/150 = 5.0 SQ. FT. A3 UNDER —FLOOR VENT PROVIDED: 1 14/12 = 1.2 x0.5x10= 5.8 SQ. F Q: 0 0 _j z Z I-— 0 V) 24" SO. x FTG. PAD TYP. Lj a _j Z Ld u 0 > L 0 V) 04 7= 0 ry co LL_ 15 Z 0 A3 0 < < z m vi < 0: < z IRS 3 Z < A3 (n 2x6 F. J. _01VO.C. 0 "0' Lo 11 C14 0 04 0 15 FOUNDATION PLAN A32 SHEET A- SCALE: 1/4"=1'-O" STUD & SOLID BLKG AT ADJOINING PLYWD EDGES. SEE SCHED R E V I S 1 0 N S FOR MIN WIDTH. STAGG. EN FROM EA. SHEET N 2X PLATE W/ 16 ,--SHEAR WALL E.N. TYP 0 8 O.C. WHERE OCCURS A DOUBLE EN. FULL E.N. E.N. AT TOP LENGTH OF if PLATE POST OR KINi t TRIMMER SEE STUD A-33 EA, MSTA 24 B.N. TYP. WALL L CA FRAIMING (N) R.R. @ 32" O.C. FRAMING DETAIL 0 NEW R.. R A \y/ X\j\, 2x RR W/ A- 0 2x SHAPED EE SCHEDU E 32"O.C., U.N.O. W/16d @16" oc 2X P.T. PLATE B.N. KING STUD OR FOR SILL PLATE E.N. U.N.O. W/ 5/8- DIA A.B. PLYWD SHEETS 0 FLOOR JOIST POST ADJACENT TO MAY BE INSTALLED NAILING AND FND 0 48" O.C., OPENING SEE VERT OR HORIZ PLAN FOR SILL 3/8- PLYWD. ---------- 2x RAFTER W/ "LUS" 2X BLKG. W 77 I - . . I U.N.O. JOIST HGRS PLANS MIN SHEET DIM TO PLATE BOLTING MIN NAIL PER 3- 10d TOE NALS A BE 24" TWO BOLTS PER 611 2x1O W/3-16( 00 HOLDOWN STRAP WALL EA. EXIST R.R. CENTERED ON POST 2x R RIDGE BM. BEAM AFTER W / QRADCAKI SEE PLANS 04 SHEARWALL SCHEDULE ALLOWABLE SHEAR LOAD CEILING JOISTS TO RR W/ 3-1 Od LXIb I N.H. 0 00 MARK SHT'G MATL HrG NAILING SILL PLATE NAILINGLAP 16d 04" O. .230 PLFTo PLYWD BLOCKED 1 Od ®12" OC FN'3 &1)B#4 OTTOM NOTES: MIN. 12" 3" CLR. 1. NAILS FOR PLYWOOD M BE COMMON. Lj] r-, 2. NAILING APPLIES AT ALL STUDS PLATES & BLKG. > 3. PROVIDE E.N. TO STUDS OR POSTS AT HOLDOWN LOCATIONS. 0 < 4. USE 2x STUDS AT 16" O.C. AT ALL SHEARWALLS, U.N.O. CL 5. 3x BLOCKING SHALL BE PROVIDED AT ALL HORIZONTAL JOINTS. 6. USE 3x FRAMING AT ALL ADJOINING PLYWOOD EDGES, STAGGER EN. ROOF FRAMING TYPICAL INT® FOOTING �- 7. PROVIDE 3x SILLPLATES THAT REST ON CONCRETE OR MASONRY 12 3 A RIDGE BEAM -L: I"=J'- 0" LNZQ�L SQ6LL: Lzl` 0" F- < FOR ALL SHEAR WALL TYPES. ry to to 8. PROVIDE 1/2" EDGE DISTANCE FOR PLYWD BOUNDARY NAILING. < K) 9. SQUARE PLATE WASHERS SHALL BE USED WITH ALL ANCHOR POST PER PLAN—," 00 BOLTS SEE FOUNDATION PLAN NOTES N 10. SHEAR WALL TYPES 2,3,4 AND 5 SHALL HAVE SPECIAL INSPECTION HD PER PLAN 2 x SILL PL. W/ 0 00 OF ALL NAILING E.N. TYP.A 75,1 ry 0 16d @ 8" O.C. SHEAR WALL WHERE OCCURS 0 USED AT ANCHOR BOLTS: 11. AT SHEAR WALLS SQUARE PLATE WASHERS SHALL BE 2 x 4 FLAT BLKG. w U.N.O. E.N. 5/8" 0 A.B. - WASHER PLATE 2 1/2"x2 1/2"0/4" 3-16d PER BLK. E.N. FLOOR JOIST z 12. ANCHOR BOLT NUTS SHALL BE TIGHTENED JUST PRIOR TO (ALT. USE SIMPSON A35 2X RIM JOIST W/ (3) 0 COVERING THE WALL FRAMING. @ 16 .. O.C.) BN 16d END NAILS — J TO BLKG. 2x RR W/ A-35 13. FOLD NAILING SHALL BE 6" O.C. WHERE FRAMING MEMBER LAJ ARE 24" O.C. 0 32"O.C., U.N.O. E.N. CA. FRMG 2 x BLKG W/3-16d A-35F 0 16" O.C. 14. STAGGER ALL NAILING LESS THAN 2" O.C. PER BLK. U.N.O. m 5/8" CDX PLYWD.--,_ 2x SHAPED PLATE W/2"O HOLES a E.N. 8d 0 6-0,.C. N.O,� 16d/BLK FOR AT11C VENT. 2 x P.T.D.F. MUDSILLI WITH 5/8"0 x 10" A.B.15. 5/8"0 x 10" A.B. @ 48"O.C. MAX. 12" F.N. 8d 0 12"O.C. U3-HOLES PERFROM CORNERS & SPLICE ENDS-10" MIN. EMBED TYP. U.N.O. BLOCK 0 48" O.C. MAX.-12" a.FROM CORNERS & SPLICE LuW/2 1/2"SQ. x 1/4" WASHER PLATE UNDER EA. NUT. FLR. JSTS-. EN cz PARALLEL DS-7" MIN. EMBED. TYPNUTS SHALL BE 11GHTENED JUST PRIOR TO COVERING TO FTG. W/2 1/2"SQ. x 1/4" V)coTHE WALL FRAMING z2x BLKG W/E.N. oe . 11 6's ElWASHER PLATE- OCCURS a.A-35's AT 32" OC 2 x CEIL. JOIST 16"UL17AT 4'-0" O.C. NAIL TOx2 RAFTER W/4-16d 2x RAFTER x E.N. PLYWOOD PLYWD SHTG. PER PLAN—, DBL TOP PLATE WHERE OCCURS 04 04 HEADER WHERE OCCURS 2� �_ -1-0) #4 TOP 5 .> ' . I , 1_� & BOTTOM ij 311 CLR. MIN. 12-3" CIR. HEA WAI, L SCHEDULE CA FRAMING TYPICAL EXT. FOOTING ICL LA007C SCALE: 1 Z2'= V- 0" 15 SCALE: I"=l'- 0" 16 kllqfflffk�5 PAK2ALL, ro io/-15r-15 17 FN207E SCALE: 1 "= 1'- 0" Zx 7 777 /_ 1'-x OLK'(5, LOCAFE'r-'5-1 OP G-516 EAPrtt- HEADER 0 W/4-16d PEP PL-K, W/ 4-16d PERIFOLK, QtJAKE _'5rK'AP Wti-11 PER PLAN 0 PLYWD FLOOR I-EN�10NING PUCXLF� _j E,N, SHTG. WIFtlIN UPPFP OF E,N, LL_ BN WATEP HEATEk, ---- ---- ---- ---- LOGA77E OR'G546 tfAPrH- V) QUAKE_,5rkAP WtrH 2 Z BLKG A-x 350 16 O.C. V) _POL15, 0 411 Apovr GOIV7 0 >< 0 U.N.O.0 F_ Ld ANICIII�op I-EG-15 -ro 0 4< 0 0 PI_A_rf�oem O)F ItLoop, > PP_f-5EE nAN 41, UJ E.N. E.N.EXIST FLR. JOIST LAG rpAp _-�_5EC'uprL-Y z FLR JOIST 7-0 WAQ- I'PIV'11NO: LAJ PEP CALK.W/ -LB' HGR EXIST FTC. - Prp CALK. 16- O.G. 4 LAG POLI _15 ANO rENDEP WA_15HEP_,5, SIMPSON ECC 15EE _,5HP, WAL-1- _15HAI-L OF COL CAP . ........ . AKIOUND WAriff' SIMPSON CC HEA rff'/N1 A MANNEDWAI-1- -Ir -5 NOT W/ /I Oof�� COL. CAP FOR INFO. NOT SHOWN SEE 3 0 0 0 _r1oN PLANK)fr, POSTS 00 PER PLAN MINIMUM ill A T_ GJ, SEE P/_AN NON-METAI_LZ GJ, f5jff PLAN v V) r,� C) 0 C4 19 � 1 1 wArEp 112,E 12,� ci� cm kl� Z 4- 16d END NAIL AT STUD Oof7 0 (-) OR TOE NAIL AT POST CLA45.� ll�Il vt1w W/ 2-6 GA o/it V. /`1 A5r11l\15 CO) / Ak, (N) PLYWOOD (E) PLYWOOD < SHEAR — WALL WHIER OCCURS- S PLAN �2 x KING TYP.) 2-2 x KING AT OPENINq OVER 6 -0 POST WITH HOLDOWN PER PLAN ­>011 c '4 1 Fl/ Ywoor,�) (N) 2x SILL (E) 2x SILLz MANUrAr-_ rl._#�'Ekl �7411wlr V; /�PONW_ 0)- GON7-R'01 -)E COW PL_�WOOD 15/Dr or UNIT IIVALIWAY 2x BLOCKING 2x F.J. FULL DEPTH PER PLAN ON "A3511 A35 < z ill GLX, MIN. TO COMPAPT Mffl\,q TO PE 1AN Z/ J Doull_�Llff - WALLF0 fWovlotf _,!5lff i`1Ak"1,T-Lf puce- (E) FTG. REINF. 0 cli 91, �001_011 MAX P.T. 2x opentrj!, Z_0Wr_P Vt:NrC,0NN_tfC�r0k' MIN combu.,fion 8- _,50F�rL_Y Ale OOD GIRDER PER PLAN /M5u, L-117 /o?v FI)AIII P91004-Dr GAS ff OLIrLr-r AT IN A r rlc_� Fo P FAU ap PER PLAN ... ... . .... . . .......... ... . . . .... 0 04 INULATION PrR' Pk'ovlr,),ff G1k'cuL_AT'1NG Alk'�5UPPL-� (N) FTG. REINF.­"� 0 O.C. (TYP) I r�rL_E 24 opowive-,5 ok, oucr wl.,;, _-5o.11v (o r1rp /000 r:-15-ru (100 TO MATCH (E) P rAu 0 z STUD (TYP.) VLfkllf�y AL-L KIL 0 0 0-1-1 00111 STUD @ 4 x 8 oul'LIDINS DrPr. NtAUtK & LAK;itK OR POST PER PLAN f 57 7 SHEET 29 0" SQ. fv NEW FOOTING EXISTING FOOTING A-3 rr1c. /t, GIff mommilamzm= "PAD FOOTIN WALI rKIA111ING AT opfIVING 131 14 15 FN201 E - __ - SCALE: 1 1'- 16 OF -E > /­SIMPs TYP. 7 S7 S OR 4 L4x HDR 16d @ 12" 1-2 x TRIMMER i 2-2 x TRIMMER REVTSTONSBY The "o/vwm ~`' 'E~~^E~~`'~ '- ALL S) Lamps used � �m�or�o �� general kitchens and bathrooms^mhoU ~~ ~^ of not less than 40 lumens per LOW RISE RESIDENTIAL buildings and shall appear as notes on the watt. (Fluorescent �mU��g �� meet th� plans: , requirement).requirement)./ A Before the buUding may be occupied, installation - Sec. 150(k) certificates for manufactured evices regulated by the Appliance Standards or Part S shall be posted adjacent to the building pennit(s). Certificate shall: T) In C|hnoha Zones 14 and 16 o vapor barrier ehuU be installed 1 Identify features required to verify uonnpUonco with the ' on the oond{�onsd space side of nU insulation � oU exterior *oUn, invented attics, and unvanbad oro*l opncno to Appliance Standards and Port 6/ protect insulation from condensation. 2. Include the statement indicating that the installed devices conform to the Appliance Standards and Part ° ` �e�. 150/q\ andthe requirements for such devices given inthe plans and specifications approved by the local enforcement U) Any new |6w-rise residential building shol} meet the mganc$ following minimum requirements: J. State the number of the building permit under which the 1' Ceiling Insulation. The opaque portions of ceilings construction or installation was performed. separating conditioned mpuuoe from unconditioned spaces or ambient air shall meet the requirements of either 1 . Sec. 10-103(o)(3)(Aj or 2 below: BA The builder shall provide the building �d Certificate(s)-' the original "^°"p='"= the appropriate ~~' a Ceilings be �au|o�d between framing members w|th�eu[otionreou|ting�oninotn||edtheonal and � |inL �f the features, materials,components, resistance of R-1Q or greater for the insulation and rneohon|ou| devices installed in the building, and ' instructions on how to use them efficiently. ALTERNATIVE to Section 150(o)1.: Insulation which San. 1O-1V3(h)(1) in not penetrated by framing members may meet on R- ` value equivalent to installing R-18 insulation [) After installing wall, ceiling, or floor insulation, the installer shelf post between framing members and accounting for the effects of framing members. in n conspicuous location in the building o certificated signed by the installer stating that the installation is consistent with the plans and requirement ofsec§on 1(2) (A) h. Floors chpU be insulated hwhxaon framing members and nunfunnn with the requirements of port 0. The certificate shall also with insulation having on installed fhmnnoi state the manufacturer's name and material identification and resistance ofg-19 or greater. the installed R-vo|ue. . . �e�^ ��-1Q�(c0(4) 2^ Loose Fill~ || Insulation. When luuoo fill insulation is installed, the minimum�installed weight per square foot shall conform with the insulation manufacturer's D) Manufactured fenestration product shall be certified for owmndl U-values installed design weight per square foot at the SHGC as rated by the Notional Fenestration Rating Council^o WFR0 200: manufacturer's labeled R-value. 1' Have o o|eohy visible temponoty |uho|' not to be removed before inspection t listing th ��ad value, solar hoot gain by the ug�»c� ns certified 3. Wall Insulation. The opaque portions of frame wells separating conditioned spno*o from unconditioned mpomam method to derive those coefficient (5HGC) of the product and he meth used or ambient air mho|| meet the requirements of either o values. Also the |oba| should ind(ookn uwmpUonoo with air infiltration or h below: requirement of Section 116(c) 1 m, Framed wd(a uhoU be insulated between framing 2^ Have o permanent label meeting the naquiemnt of section 10-111(A)(2) members with insulation having on installed thermal resistance of R-13 or greater. Framed foundation orQon|zot|on, and rating 9rnnedures' woDy of heated basements or heated crawl npopem Sec. 116(c) shall be insulated above the adjacent outside ground line with insulation having on installed E\ -' Field fabricated skylight and windows, and exterior doors, shall be thenno| resistance of at |000t R-1J. . weather -stripped. ALTERNATIVE to Section 150(c)1': Insulation which EXCEPTION: Unframed g{omm doors and fire doors. in not penetrated by framing members may meet on R- volue equivalent to installing R-13 insulation between framing members and accounting for the �e�. 11�(h) ' thermal of members. F1 Joints' and other openings inth b building envelope that mna . b ' The weighted average U-vn|ue of*d|o shall -not exceed the U_voiue that would result from potential sources of air{eokoge shall be caulked, gaotac\ *eothmmthppwd or otherwise sealed to limit infiltration installing R-13 insulation between framing members and exh|trmtiun. and accounting for the effects of framing members. Sac 117 4. Raised Floor Insulation. Raised floors separating conditioned All insulating material ahu|| be installed in compliance with opunoa from unconditioned mpooeo or ambient airshallmeet the spaces the 8omeopreod rating smoke density requirements of Sections of either a. or t^ below. 707 of the U8C. o. Floors nho|| be insulated between framing members See. 118(o) with insulation having on [nshzKpd ihenno| resistance of R-13 or greater. H] Heat pumps with supplementary a|ontho resistance heaters ohoU have controls: h. The weighted average U-value nffloor assemblies 1. That prevent supplementary hooter operation when the heating |unn can ahoU not exceed the U-volwe that would result from be met by the heat pump alone; and installing R-13 insulation between framing members 2. In which the t temperature for re siun heating is higher than and accounting for the effects of framing members. the cut -on tamcnoturo for supplementary heating, and the cut-off See. 150(o)-(d) temperature for supplementary heating. Sec. 112(b) |) Masonry or factory -built fireplaces ohoU have the following: 1. Qqmonble metal or glass doors covering the entire opening of the firahnx. 2. A combustion ok intake to draw air from the outside of the building directly into the firebox, which is at � !nmot six mqumpo inches in area and is equipped with o SUPERIOR WINDOW & DOOR THERMAL AND OPTICAL RATINGS WITH AND WITHOUT GRIDS w/o .71 1 .71 .55 _47 .59 1 .52 .41 62E .75�59 oRoC-ov�,numG�nnvmxcwm vT'vbmmnan��mno. LoW��'H�hy�mnn�r Low ssho ornp1hance: Residential (Part 1 of 2) SINGLE HOUSE ADDITION 8/26/05 Project Title Date Project Address Building Permit # PERFECT DESIGN & ENGINEERING, INC. J16%22L6) 289-8808_ Plan Check I Date Documentation Author Telephone Computer Pe rmance Field Check I Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: Ceiling ft Total Conditioned Slab Area: Mp Building Type: (check one or more) EXI Single Family Detached Addition Single Family Attached El Existing Building El Multi -Family �� Existing Plus Addition Front Orientation: Floor construction Type: F-1Slab Floor Number ofDwelling Units: Number of Stories: J`��l Raised Floor LZSJ COnoL ' ,o ponent Frame Assembly Location/Comments .Ty2e, e U-Value (attic, garage, typical, etc.) R-19 ELoqr1E:_1g.2x8.16 Wood 0.038 Exterior Floor / Over Crawls2ace Lw/E:§ Cred!Q °'r1=^, tinaging Devices Type Orientation Area Fenestration Exterior Overhang Side Fins El R El R R El El El �� pliance: Residential (Part 2 of 2) CFAR ,SINGLE HOUSE ADDITION 8/26/05 Project Title Date HVACSYSTEMS Note- Input Hydronle or Combined Hydronic data under Water Heating Systems, exce - pt,Design Heating Load. Distribution Heating Equipment Minimum Type and Ductor Type (furnace, heat Efficiency Location Piping Thermostat Location pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R-ValUe Type Comments HQUSE.- Cooling Equipment Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc-.) R-Value Type Comments WATER HEATING SYSTEMS 1 Rated1Tank Energy lxtemal Water Heater Water Heater Distribution #in Input Cap. or Recovery Standby System Name Type.__ Type Syst. Tank Insul. Btu/hr (gal) Efficiency (%) R-Value ,Loss I For small gas storage (rated Inputs of less than or equal to 76,000 Sitti/hr), e-lecWo re-sistance and heat _p ump water heaters, list energy factor, For large gas storage water heaters (rated Input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For Instantaneous gas water heaters, list Rated Input and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance California Code of Regulations, and the administrative specifications needed to comply with iUe24,Pa land6of e Ti rts th regulations to Implement them. This certificate has bee overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requir n signed by the Individual With Installer and field verification by an approved HERS rater. es testing and cerfification Designer or Owner (per Business & Professions Code) Documentation Author Title/Firm: GREGORIO ART AYALA Title/Firm: Address: 2108 W. GAGE AVE, PERFECT D ON INC. Address: 2416 W. Telephone: AJhamb (signature) (date) Enforcement Agency (date) m readily mooesomw. operable, and Eight Mune damper or combustion air control device. -'Mmnd=on�MeaSU�S Checklist: �_s~�em_�'"/�e -n-\ NOTE- '-' required'is Installed over o ntial ��~�� ---- re ��"��`a' concrete slab and will not be located on on Certificate NOTE:���msmo�uummm» »mm�momom»�m'mum�n�"mv�pv�"=°'°�=,°~the ~~'~^�^=~~ used, Ite'---NOTE: ���um�o�m����c�����rdless of the complian�this checklist Is Incorporated Into m asterisk Mmay bvsuperseded o'more stringent compliance requirements mte«mmeo^m«camof Compliance, When this checklist ° Incorporated i'~ asterisk Mmay be superseded bymore stringent compliance requirements listed oothe Certificate mCompliance. When � aummmno»��x�m,,m,mu�mmomvmv��"� exterior woU^ omvwmxuv�moomthe mmunmnnmov�o,v�,nmunm�all -�mwus�n/mom�mvonum»n«nnn��s�ama�nvm,momn««am�m*mo�o mn�=mom"memu.the �om�s�umo�«�umm�m«�»�omu»*om/"�mm�m»o�»»» � s A n.'e anmner with omodUv accessible oontnd. SINGomo ..�,.,~.^~',~~-',/,=*°=/,m°«000mnxuo,vo�s�o�nston� mmmmm�am,��m�xo�m�mmoom�momvo,o»�»mmmm*�� ��r� EXCEPTION: Special Features and Modeling � decorative gas appliance is installed in pay special attention to the items specified In this checklist. These Items require special The local onfOrcOmOnt agency should ca a fireplace, the flue damper shall be ontation, and special verification to be used with the performance approach. The to I written justification and docum f the justificatl0n, and may reject a building or design that otherwise complies blocked open if required by the enforcement agency determines the adequacy 0 not documentation submitted. Plan Field manufacturer's installation instructions based on the adequacy of the special justification a or the State Mechanical Code. The DHW system 'RHEEM 22VR75-70N (75 GAL,r Energy Factor = 0.530. An EF below 0.58 requires an R-1 2 External BlankeL � of indoorair for cooling a firebox jacket, when that indoor air Soo 15O(@J) All heating and/or cooling systems other than wood stoves K) The air handling duct system shall be constructed, installed, sealed and insulated as provided in Chapter 6 of the Uniform Mechanical Code, (Must be insulated to a minimum installed level of R-4.2 or be in conditioned space). L) All fan systems exhausting air from the building to the outside shall be provided with backdraft or automatic dampers to prevent air leakage. Sec. 150(m)7 M) Storage gas water heaters with an energy factor<0.58 shall be externally wrapped with insulation haVing installed thermal resistance of R-12 or greater. Sec. 150(j)1A N) Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water heating systems, shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater or have internal insulation of at least R-16 and a label on the exterior of the tank showing the insulation R-value. See. 150(j)18 0) Duct system opening shall be sealed with mastic, tape, aerosol Sealant, or other duct closure system that meets the applicable requirement of UL 131A, or UL181B including collars, connections and splices. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. P) Building cavities shall not used for conveying conditioned air. Q) Joints and seams of duct system and their components shall not be sealed with cloth back rubber adhesive duct tape . s unless such tape is used in combination with mastic and drowbands. R) Piping, buried or unburned, for rech-culating sections of domestic hot water system. piping from the heating source to the storage tank for an indirect -fired domestic water heating system, cooling system piping below 55 F, and the first five feet of hot and cold water pipes from the storage tank for non -recirculating systems shall be thermally insulated In accordance with table No. 1- T. Sec. 150(j)2 w�D�o"m�mdVer�n��n to if rhese features must be confirmed and/or tested cortmect ricr%Q laLul ­t­�-­­ - - f F-6R. provider. The HERS rater must document the fielivarification and diagnostic testing o t ese measures on a orm C Fla told Run Initiation TlmwA8/26105 1-0;42*08 Run Code: _1_125nr81zt5 ~~~.~~~.~--�____DESCRIPTION instructions: Check or Initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT `mnmm�vam�"�°�==�"..~.�.~~~~~---_---_ DESCRIPTION instructions: Check or Initial applicable boxes or enter NIA If not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) in n 1. All ducts and plenums installed, sealed and Insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts Insulated to a minimum installed level of R-4,2 or enclosed entirely In conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct-clasure system that meets the applicable requirements of UL181, UL181A, ort.11.181B. if mastic or tape Is used to seal openings greater than 1/4 Inch, the combination of mastic and either mesh or tape shall be used. Building Cavities shall not be used for conveying conditioned air, joints and seams of duct systems and their components $hall not be sealedvilth cloth back rubber adhesive duct tapes unless such tape Is used in combinationi'mth mastic and Z Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air, Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms $hall not be compressed to cause reductions In the cross -sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape Is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. S. Gravity ventilation systems serving conditioned space have eltherautomarlic or readily accessible, manually operated dampers. 6. Protection of insulation. Insulation shall be Protected train damage, Including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e,g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam Insulation shall be protected as above or pointed with a coaling that Is water retardant and provides shielding from solar radiation that can cause degradation of the material. JK§ 114: Pool and Spa Heating Systems and Equipment 1. Certified wab 78% thermal efficiency, on -off switch, weatherproof operating Instructions, no electric resistance heating, and no plIoL 2. System is Installed with at least 36' Of Pips between filter and heater for future solar, cover for outdoor pools or aAt least 36* of pipe between filter and heater for future solar hearting. b. Cover for outdoor Poole or outdoor spas. 3. Pool system has directional Inlets and a circulation pump time switch, §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non-efectlical cooking appliances with Pilot < 150 Btufhr) §118 (0: Coal Roof material meet specified criteria §150(k)l: Luminaires for general lighting In kitchens shall have lamps with an efficacy 40 lumenshvatt or greater for general lighting In kitchens, This general fighting shall be controlled by a switch on a readily accessible fighting PROJECT NAME SINGLE HOUSE ADDITION 8126/05 FLOOR AREA SYSTEM NAME 97.2/emOF | Outside Air | ncfm 179.5/62.6')F Supply Fan Cooling Coll �% Return Air Ducts "I Supply Air Ducts L( uma/n41q= 40.4% R.H. L[���� mm Sheet /`[_1� kJ�_1� ��/ '/`,mv //. 8c MANDATORY REQUIREMENTS Of Sheets