HomeMy WebLinkAbout10150074.pdfNFP, .. Ni 5 1. EXCEPT WHRERE MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN ON THE PLANS, WORKMANSHIP * MATERIALS SHALL CONFORM TO 2001 CALIFORNIA BUILDING, PLUMBING, MECH- NICAL AND ELECTRICAL CODES, AND LOCAL ORDINANCES. 2, THE PLANS SHALL BE REVIEWED FOR DIMENSIONAL * EXISTING SITE CONFORMANCE WITH THE PLANS BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. THE ARCHITECT * ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 3. WORKING DIMENSIONS SHALL NOT BE SCALED FROM DRAWINGS. 4. ITEMS IDENTIFIED BY TRADE NAMES MAY BE SUBSTITUTED BY APPROVED EQUALS. 5. NOTES * DETAILS ON DRAWINGS SHALL PRECEDE THESE GENERAL NOTES G. PROVIDE ANY SHORING * OR BRACING PRIOR TO REMOVING EXISTING WALLS, BEAMS, OR SUPPORTS FOR CONSTRUCTION. REMOVE SHORING ONLY WHEN NEW SUPPORTS ARE IN PLACE AND SECURED. 7, PROVIDE RED HEADS INTO EXISTING CONCRETE AT ALL SHEAR WALLS PER MPG, SPECIFICATIONS. SEE SHEAR WALL SCHEDULE FOR 512E AND SPACING. 8. THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES WHETHER OR NOT SHOWN ON DRAWINGS AND PROTECT THEM FROM DAMAGE. 9. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS FOR FOOTINGS, BEAMS AND JOISTS, 51ZE5 LOCATIONS ETC. AND SHALL NOTIFY THE ARCHITECT * ENGINEER OF ANY DISCREPANCIES. 10.5EPPARATE PERMIT 15 REQUIRED FOR MECHANICAL AND ELECRICAL WORK. ND OF PAGES1 / f 1. . 1 v S n. n. ... MAPS, RECORDS O , . .. ,. „ .n a CALIFORNIA, Lot Size: ,33. S.F, Byilding Size: iytinLiving: 11265. S.F. New Room Addition: .F. 1,55% S.F. VICINITY MAP ,00 f N OTE5 1. VENTILATION: ATTIC AREA = 904 S.F. LOWER VENTING TO BE PROVIDED WIVENTING BLOCKS @ 24" O.C.. HIGHER VENTINGTO BE PROVIDED W1 (4) I -SF DOMER VENTS (3.0 S.F. REQUIRED) 2. ALL ROOFING TO BE INSTALLED OVER (2) LAYERS 30 LB. ROOF FELT WEATHERBOARD LAP 3. NO ROOFING PENETRATIONS SUCH AS PLUMBING, VENT, ETC, TO OCCUR WITHIN I'-G" OF VALLEYS, HIPS OR RIDGES 4. ROOFING MATERIAL SHALL BE ASPHALT SHINGLES, ICBO 554G 5. ROOFING MATERIAL SHALL NOT EXCEED 2.5 P5F M 0 T SCALE 1"=10'—O" ... , . .. s. S < R E F '�....... .a t v. Lf- GND 5LOPEf'%FT Q ONE 5F G.I. DORMEK VENT — 5LOFE 3:12 REVISIONS BY • U, • • 1 � � • ' s ,f C3 O N im LO ;o c 0� r co 04 < U cv cn r- w O n DATE MAY 2, 2005 SCALE AS SHOWN DRAWN BY JOB NO. M.G. PPROVED BY SHEET REVISIONS BY v FRONT ELEVATION SCALE 1 f 4"=1'-O" REArt-,<"' ELEVATION SCALE 1 f 4"=1'--0" v f7 ToR 14'-3" ELEVATI011 SCALE 1 f 4"=1'-O" �� LEFT ELEVATION SCALE 1 j4"=1'-O" 4w U w • M w • w ............. r. Q C> cv m I 2 m tV <t U 04 (1) I`- e e W O Gl! A#Rey jr 0 � 2 C-23941 RE 7/31107 DATE MAY 2, 2005 SCALE AS SHOWN DRAWN BY JOB NO. M.G. PPROYED BY SHEET A. All beams to be supported with full bearing U.N.Q. B. All isolated posts and beams to have 5omp5on PB's, PC's and/or BC's minimum, U.N.O. C. All bearing walls on wood floors are to be supported with double Joists or solid blocking, U.N.O, D. Provide 4x or double members under sole plate nailing less than G" o/c. E. All Simpson HDA, HPA, and CB holdowns to be fastened to 4x4 post minimum. F. All hardware to be Simpson Strang -Tie or approved equal. Install per mfr's specifications, G, All shop drawings are to be reviewed by the contractor and the architect prior to submittal for engineer's review, H. All exterior walls are to be secured with 5/8" diameter x 10" anchor bolts cz 72" o.c., U.N.Q. I, All non -bearing or non -shear interior walls to be secured with shot pins per manufacturer's recommendations, U.N.O. Calculations govern all cases. J. All conventional framed portions of structure are to be constructed per 5ection 2320 of the Uniform Building Code, U.N.O, K. All nailing is to be per table 23-1 1-b- J of the Uniform Building Code L. All nails to be "common", U.N.O. M. Notching of studs in bearing partitions shall not exceed 25% of the width N. Notching of studs in non -bearing partitions shall not exceed 40% of the width 0. Bored holes in studs in bearing partitions shall not exceed 40% of the width P. Bored holes in nonbearing partitions shall not excees GO% of the width (unless the bored studs are doubled and no more than two such successive doubled studs are so bored) Q. Bored holes may not be located nearer than 5/8" to the edge of the stud and may not be located in the same section of the stud as a cut or notch R. Provide double top plate with minimum 45" lap splice, (8)- 1 Gd nailing (CBC 2320.1 1.2) DOUGLA5 FIR- LARCH- 19% MAXIMUM MOISTURE CONTENT 2x4 #2 Fb= 13 15/1 G 10 psi fv=95 psi E= I .GxG,5 #2 Fb= 1 140/ 1300 psi fv=95 psi E=1.G 2xG #2 Fb= 1 14011310 psi fv=95 psi E= i .fix 10 #2 Fb= I OG011200 psi fv=95 psi E= I .G 2x8 #2 Fb= 1055/ 1210 psi fv=95 psi E= I .+fix 12 #2# 1 Fb= 9G5/ 1 100 psi fv=95 psi E= I .G/ 1.7 2x 10 #2 Fb= 9G5/ 1 105 psi fv=95 psi E=1,G4x 14 #2# 1 Fb= 875/ 1000 psi fv=95 psi E= I .G/ 1,7 2x 12 #2 Fb= 875/ 1005 psi fv=95 psi E= I .G4x 16 #2# 1 Fb= 875/ 1000 psi fv=95 psi E= I ,G11 .7 2x 14 #2 Fb= 790/905 psi fv=95 psi E= I ,G Gx 10 # 1/55 Fb= 1350/ 1 GOO psi fv=85 psi E= I .G It is recommended that lumber be free of heart qgr # 1 /55 Fb= 1350/ 1 GOO psi fv=85 psi E= I ,G Glued Laminated Beams; Douglas Fir Larch PARALLAM P5L 2.0E Ind. App. Grade Fb=2400 psi FV=1 G5 psi E= I .GEG p5rb=2900 psi FV=290 psi E=2.OEG psi Glue -lam beams shall be marked ANSI/AITC Standard A 19(VIICROLAM LVL Fb=2GOO psi FV=285 psi E= I .G Wooden structural panels shall comply with UBC Standard 23-2 (P51-95) or 23-3 (P52-92) 5tructural Composite Lumber manufactured by Trus Joist MacMillan ICBO E5 PFC-5G7GP Wood connectors manufactured by Simpson IC50 121 1, 3G31, 4935, 4945, 51 17, 52G8, 5279, 5313, 5328, 5349, 5357 I. Joist to sill or girder toenail 3-8d 19. Rafter to plate toenail 3- 8d 2. Bridging to Joist, toenail each end 20. 1 " brace to ea stud end plate facenail 2- 8d toenail each end 2-86 21 . 1 "0' cheating or less to each bearing 3. 1 NG" subfloor to ea/Joist, face nail facenail 2- 8d face nail 2-8d 22, Wider than I N8" cheating to each bearing 4. Wider than I " x G" subfloor to each Joist facenail 3- 8d face nail 3-86 23. Built-up corner studs I Gd @ 24" cc 5. 2" subfloor Jto Joist or girder, 24. Built-up girder and beams 20d @ 32" o.c. top blind and face nail 2-1 Gd and bottom and staggered 2-20d @ ends and splice G. 5ole plate to Joist or blocking, 25. 2" planks 2- 1 Gcl� t each bearing typical face nail i Gd @ i G" oc 2G. Wood structural panels and parhicleboard: 501C plate to Joist or blocking, at braced wall panels 5ubfloor and wall sheathing (to framing) 3- 1 Gd per I G" 112" and less Gd3 7. Top plate to stud end nail 2- 1 Gd 19/32" - 3/41' 8d or Gd 5 8. 5tud to sole plate 4- 8d toenail, 2-1 Gd endnail 7/81" - 1` 86 5 9. Double studs, face nail 1 Gd @ 24" cc 1-1 /8" - 1-1141" 1 Od or 8d 5 10. Doubled top plates, typ face nail Gd @ I G" cc Combination subfloor-underlayment (to framing) Double top plates, lap splice 8- 1 Gd 7/8" - I " 8d 5 1 1 , Blocking between Joists or rafters to top plates I -1 /8" - I -1 141' 2 1 Od or 8d 5 toenail 3- 8d 27. Panel siding (to framing) 12, Rim Joist to top plate toenail 8d @ G" oc 112" GdG 13. Top plates. lap and intersectiofacenail 2- 1 Gd 5/8" 7 8d G 14. Continuous header, two pieces 1 Gd 1 G" 28. Fiberboard sheathing: O 112" @ along each edge No. I i ga8,Gd4 , No. I GgaD 15. Ceiling Joists to plate toenail 3- 8d 25/32" No. I I ga8,8d4 , No. I Gga I G. Continuous header to stud toenail 4- 8d 17. Ceiling laps 29. Interior paneling 10 114" Joists, over partitiofacenail 3- 1 Gd 4d I 1 18. Ceiling Joist to parallel rafters facenail 3- 1 Gd 318" Gd I Common or box nails may be used except where otherwise stated 2 Nails spaced at G inches oc at edges, 12 inches cc intermediate supports exzcept at G inches where spans are 48 inches or more. Nails for wall sheathing m be common, box or casing. Refer to sections 2315.3.3 and 2315.4 for shear nailing. 3 Common or deformed �#tumonI eformed shank G Corrosion -resistant siding or casing nails conforming to the requirements of Section 2304.3 7 Fasteners s aced 3 inches on center at exterior edgqes and G inches on center at intermediate sup arts 8 Corrosion -resistant roofing nails with 7/ 1 G diameter head and 1-1 /2" length for I /2" sheathing and P -3/4" length for 25{32" sheathing 9 Corrosion -resistant staples with nominal 7/ 1 G" crown and I -1 /8" length for 112" sheathing and 1-112" length for 25/32" sheathing 10 Panel supports at I G mches [20 inches if strength axis in the long direction of the panel, unless atherw+se marked]. Casing or finish nails spaced G inches on panel edges, 12 inches at intermediate supports I 1 Panel supports at 24 mches, Casing or finish nails spaced G inches on panel edges, 12 inches at intermediate supports. I . Drypack shall decomposed of one part Portland Cement to not more than three parts of sand. 2. All structural concrete fc=3000 psi w/inspection All slab-on-grade/continuous footings/pads fc=2500 psi w10 inspection All concrete shall reach minimum compressive strength at 28 days, 3. 1905.8.2 Ready -mixed concrete shall be mixed and delivered in accordance with requirements of A5TM C 94 (Ready -Mixed Concrete) 1. All reinforcing shall be A5TM A-G 15-40 for #5 bars and smaller All reinforcing shall be A5TM A-G 15-GO for #G bars and larger Welded wire fabric to be A5TM A-185, tap 1-112 spaces 9" min 2. 5pacing of bars shall have lappings of 40 dia. or 2'-0". This is in all cases U.N.O. (30 dia. for compression). 3. All reinforcing bars shall be accurately and securely placed befor pouring concrete, or grouting masonry, 4. Concrete protection for reinforcement shall be at least equal to the diameter of the bars. Cover shall be as follows, U.N.O.: A. Poured against earth ............... .................. i "51ab5 on grade (from top of slab)..... i B. Poured against form below grade .......... 2" D. Columns and beams to main bars ............. I I . Fabrication and erection of structural steel shall be in accordance with "specifications for the Design, Fabrication and Erection of 5tructural Steel Buildings", AISC, current addition. 5teel to conform to A5TM A3G. Round pipe columns shall conform to A5TM A53, Grade B. 5quare/Rectangular steel tubes A5TM A500, Grade B. 2. All welding shall be performed by certified welders, using the Electric 5hielded Arc Process at licensed shops or otherwise approved by the Bldg. Dept, Continuous inspection required for all field welding, 3. All steel exposed to weather shall be hot -dip galvanized after fabrication, or other approved waterproofing method, 4. Where finish is attached to structural steel, provide 112" dia bolt holes @ 4'-0" o.c. for attachment of nailers, U,N.O. 5ee architectural drawings for finishes (Nelson studs 112" x 3" CPL may replace bolts), NOf5a I .TOP OF FTG SHALL BE @ ELEV. 0-0" UNO. 2. VERYFY ALL DIMEN51ON 5HOWN WiTH ARCHITECTURAL DRAWINGS, 3. UNLE55 OTHERWISE NOTED, LOCATE HINGE 51DEOF ALL DOORS G" FROM ADJACENT PERPENDICULAR PARTITION, 4. LOCATION OF HOLDOWN AND SHEAR WALL5 SHOWN ON FOUNDATION PLAN ARE APPROXIMATE ONLY. COORDINATE LOCATION WITH ARCH. DWGs 5, CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL EQUIPMENT/ACCE55ORIE5 MOUNTED ON WALL. G. ALL. ANCHOR 5QLT5 AND HOLDOWN5 SHALL BE TIED iN PLACE PPJOR TO FOUNDATION INSPECTION, 7. ALL NEW EXTEPJOR WALL SHALL HAVE e," (24/0)CDX 5TRUCT I PLYWOOD W181) NAILS @ G"-12"-12" UNLESS NOTED OTHERWISE ON PLAN 8, FOUNDATION ANCHOR BOLTS IN WALLS SHALL HAVE AN APPROVED PLATE WASHER UNDER EACH NUT;AND THE NUT SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. PLATE WASHERS A MINIMUM OF 2`X2` E" THICK SHALL BE USED ON EACH BOLT. (I 80G.G,1) IN] FOUNDATION 5. CONNECT ALL NEW FOOTING5 TO EX15TING FTG5 AND 5LAB5 ACCORDING TO DETAIL5 9. CONNECT NEW TOP PLATES TO EX15TiNG TOP PLATE ACCORDING TO 1 10. SEE (DFORTOP PLATE 5PLIE 11. DRAWING AND WORK MUST SHOW COMPLIANCE WITH GENERAL AND CONVENTIONAL REQUIREMENTS OF CBC SECTION 2320 AND CHAPTER 18 FOUNDATION REQUIREMENTS, I*\00F FRAWNG PLA�§ SCALE 1 j4"=V-0" REVISIONS BY .. , , .. • , C14 0) • • r 4 CD E r_. O �� � CV rn v 0 o C V) Vi i t in O a coo 0 0 0 p r- Q CU C14 to r-». 6 C) LLJ ry - DATE MAY 2, 2005 SCALE AS SHOWN DR,�WN BY JOO NO. M.G. PPROVED BY SKEET WOOD SIDING .Nl� M-�NG PER PILAA," "A. 2x4 @ 16"O.C. wall framing 1. CEILING JOIST 314" PLYWD SUB FLOOR See Plan R-13 GATT INSUL S R ER 2. 1 X8X24" B.S. FLOOR FRAMING R,C­0' �,_,F EAT,- N 8 i*) D W/14-16D NAILS R-19 BATT INSUL SEE PLANS SEE PL'11111'�i`.-J;s SHMPLAP, 3. JOIST BREAK 5/8*x12" AB w12" plate wshr 4. BEAM W/7" Win Embedment into Conc. 7 SHTHNG Hi See Plan oc max,1 comers max EQ. EQ. P.T. 2x plate A )RAF.'TER5 �,Ni'; 2 X 3 L,`< G. stucco gmund -j N R,R, 'N" 1 ei,,.Cj 2 lal z SH;EAR R CONT RB + + Z W 2 P ER R "l L E'; OR E'� E ' 0 FACE") OR 17 SHEAR WALL CONNECTION TO ROOF 13 DETAIL 5 CEILING JOIST SPLICE 1 FOOTING DETAIL 1. W8126 at Plate Break, LINO.(or CS16 Strap) NEW FOUND. EXIST FOUND. WOOD POST PER PLAN, 1. DbI fop Plate 2. Dbl.Top Plates Typical. PLAN Le See Plan 3. 2X Blocking on Edge. 2. Simpson ST6224 Unless Interrupted by Window w2 #4 DOVVEL TYP. fLR JOLT 3. Top Plate Break PER PLAN --7ER TRAN''3 4. DbI Studs 72 30" UNO8d at Every Nail 8d at Every Nail ... SIMPSON Hole. Hole. "CI311 2X SILL EQ. EQ. TYPE BASEA PLATE. r CONN. 71 2 d. (E) STEM WALL V,/ALL V I" Gil A Ab 7. 4 4 'N E, 2 7­ S A 2 911 G"dia HOLE AN STUD WALL NA�LU,�".' PER. L ~�4. "a 4 L i w EPDXY FILL TYP. "AR ff CONC. FTG -iEE PLAN SEE FTG SCHDL OOF, '�ZE,'41-11.ERE FOR SIZE AND R REINFORCEMENT ELEVATION RELD �-,,;A�LiNG C 18 INT. PAD FOOTING 14 DETAI L 10 DETAIL 6 l' EILING/PLATE TIE 2 NEW FOOTING CONNECTION 1 Beam 1—BOUNDARY NAILING 2. Post or Mult. Stud. 2—INTERMEDIATE NAILING 3. 2X Studs 3—EDGE NAILING 1 4 3 4. Simpson MSTI 36 4—PLYWOOD SHEET or ST6224* 5—JOIST 5. Flush Beam 6. (3)16d E/S (e) SLAB & FOOTING 4 U.N.0 5 6 MIL POR BARR,,. 2 L FO. L Ftl 1, 4 fill 24" 4- FRAMING MEMBER f a a d 4 \/��` \�\ EQ FO_ XNX A N 2x TRIMMER HOLDN SPECSEE 10 PLAN FOWOR . 6 9/16"dia HOLE .4 #4 DOWELS 0 24"o/c A EPDXY FILL 4'0 • T. PLAN BOLTING PER CONDITION MFG. 4/ PER MFG ANCHOR BOLT PER 19 HORIZONTAL PLYWOOD SHEATHING CHART BELOW — SEE 11 D ETAI L 7 DETAIL 3 NEW CONC. SLAB TO EXIST. FTG PLAN FOR SPECIFIED HOLDOWN. SEE PLAN FOR MONO— LITHIC OR TWO —POUR 2x MUDSILL SPECIFICATION HOLDOWN1 ACHOR BOLT TO L BE TIED IN PLACE PRIOR TO POUR IFOR ARCHITECT'S FOOTING INSPECTIO i N ST6224 ACROSS RIDGE MEMBER RAFTER TOPS 2x6 COLOR TIES @ 0 48" O.C. 32- O.C. WITH (6) 16d 2xCONT w/16d ROOF SHEATING 0 SPECIFIED @ EA. END TYPICAL R.R. PER PLAN @ 16" O/C. CALIF.FRAMING. SHEATHING ROOF RAFTER PER PLAN 2xMAIN R.R. SPECIFIED OR TRUSS. 2xR.R. RIDGE SEE PLAN 2x6 DIAGONAL BRACING EXTEND R OF WITH (6) 16d 0 EA. END CLXATW1K1f' TO WOOD BEAM PE PLAN. SIMPSON "ECC" COL. CAP, SOLID WOOD POST, SEE PLAN FOR SIZE & LOCATION. ANCHOR BOLT SELECTION TABLE INS ALTERNATE SPACING WITH LOR TIES @ 32" O.C.ALL PER PLAN Win HU 2X HANGER TYP. \\— (4) 16d TYPICAL REVISIONS BY I • • lift C*14 (71 0 C:) C: 0 04 0 0 C3 <U RAP VI 0 Of" CL DATE MAY 2, 2005 SCALE AS SHOWN DRAWN BY JOB NO. M.G. PPROVED BY SHEET S 2