HomeMy WebLinkAbout10150817.pdfGENERAL NOTES. 1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: THE LATEST EDITION OF U.B.C. AND THE DRAWINGS AND SPECIFICATIONS. 2. THE CONTRACTORS SHALL BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING DURING CONSTRUCTION AND SHALL PROVIDE ADEQUATE SHORING, BRACING AND GUYS DURING CONSTRUCTION, SAFETY AND BRACING REQUIREMENTS SHALL BE ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL SAFETY ORDINANCES. 3. THE CONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENTIONS. ALL DISCREPANCES SHALL BE CALLED OUT TO THE ATTENTION OF THE OWNER AND BE RESOLVED BEFORE PROCEEDING WITH THE WORK" 4. FRAMING CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE FRAMED SIMILAR TO TYPICAL DETAIL SHOWN FOR RESPECTIVE MATERIALS AND SIMILAR CONDITIONS. 5. DESIGN SOIL BEARING PRESSURE: 1000 P.S.F. 6. MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE 0 28 DAYS: 2500 P.S.L. GRADE C CONCRETE 7. CEMENT SHALL CONFORM TO ASTM: C-150 8. CONCRETE MIX: 1: 2 - 1/2 : 3 - 1/2 WITH MAXIMUM WATER CONTENT OF 7 - 1/2 GALLONS PER SACK OF CEMENT. 9. FRAMING REQUIREMENTS SUCH AS NAILING, LET -IN DIAGONAL BRACES, ETC., SHALL BE PER MINIMUM REQUIREMENTS OF THE APPLICABLE LOCAL CODE UNLESS GREATER REQUIREMENTS ARE INDICATED ON PLANS OR SPECIFICATIONS. 10. FRAMING LUMBER SHALL BE DOUGLAS FIR LARCH MC19: 2X FLOOR JOISTS............................................NO. 2 2X ROOF JOISTS...........................................NO. 2 4X BEAMS......................................................NO. 1 6X BEAMS......................................................NO. 1 2X4 OR 04 STUDS OR POSTS..................STANDARD OR STUD GRADE 2X6 STUDS OR GREATER ...........................NO. 2 6X POSTS OR GREATER.............................NO. 1 11. PLYWOOD USED AS FLOOR OR ROOF SHEATHING OR AT SHEAR WALLS SHALL CONFORM TO PS 1 - 66 AND SHALL BE STAMP -GRADED BY THE AMERICAN PLYWOOD ASSOCIATION. PLYWOOD SHALL BE INTERIOR TYPE WITH EXTERIOR GLUE. 12. DUCTS SHALL BE CONSTRUCTED, INSTALLED AND INSULATED ACCORDING TO THE REQUIREMENTS OF THE LATEST EDITION THE UNIFORM MECHANICAL CODE. 13. DOORS AND WINDOWS (INCLUDING SKYLIGHTS) BETWEEN CONDITIONED AND UNCONDITIONED SPACES MUST BE FULLY WEATHERSTRPPPED. CAULKING OR SELANTS OR WEATHERSTRIPPING MUST BE USED TO LIMIT INFILTRATION IN THE BUILDING ENVELOPE AT THE FOLLOWING OPENINGS: A. EXTERIOR JOINTS AROUND WINDOWS AND DOORS FRAMES. B. BETWEEN WALL SOLE PLATES AND FLOORS PLUMBING, ELECTRICITY, AND GAS LINES. C. PENETRATION IN WALL SOLE PLATES AND FLOORS FOR PLUMBING, ELECTRICITY, AND GAS LINE D. OPENINGS ON ATTIC FLOORS. E. ALL OTHER OPENINGS IN THE BUILDING ENVELOPE. 14. MANUFACTURED DOORS AND WINDOWS MUST BE LABELED AND CERTIFIED ACCORDING TO SECTION 2-5352, TABLE 2-53V, STANDARD FOR DOORS AND WINDOWS, OF THE STANDARDS. 15. AIR LEAKAGE FROM EXHAUST FANS OR OTHER EXHAUST SYSTEMS SHALL BE PREVENTED BY USING BACKDRAFT DAMPERS OR AUTOMATIC DAMPERS. 16. NO HEATING, VENTILATING, AND AIR CONDITIONING EQUIPMENT SHALL BE INSTALLED UNLESS THE MANUFACTURER HAS CERTIFIED THE EQUIPMENT WITH THE CALIFORNIA ENERGY COMMISSION. 17. MAINTENANCE INFORMATION. THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. (C96.57.7.1) 18, AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING THAT THE INSTALLATION IS CONSISTENT WITH THE PLANS AND SPECIFICATIONS DESCRIBED IN SECTION 10-103 (a) 2.A AND FOR WHICH THE BUILDING PERMIT WAS ISSUED AND CONFORMS WITH THE REQUIREMENTS OF PART 6. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURE'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED R-VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED INSTALLED DESIGN DENSITY FOR THE DESIRED R-VALUE (C98.57.7.2) L- , _._._._._._._._._._._._.P/ --- �._._._ _ — — _ _ _ — — ——._._._._._._.—._._._._ _._._ _.----- .--- GRASS I• .I .I { m I j I N F- j 30'-10" 19'-5" 5'-0" f I O f{ M f ROOF I ! I PROJECTION 4'-0" I f�----- j l ADDITION r------------------- I i f �I PROPOSED i II EXISTING ±326 S.F. j I .I I DWELLING j I ±1367 S.F. I I I I______________________ _.__ ---j I NEW i jl i j I KITCHEN ROOM EXISTING ! { I r MASTER i 1 BED ROOM 01 r r EXISTING i -_---� i . LIVING ROOM E I i EXISTING KITCHEN i ' -� TO BE REMC?ELED i k i I. I TO NEW FAMILY ROOM i Eq ir r Ic I i I ENTRY j a ; EXISTING EXISTING r BED ROOM 02 BED ROOM 03 1 �f r � r I• r r , r {I r � •j L---------------------------- I j EXISTING r 0 02 CAR GARAGE ; f ±483 S.F r a rj I t------------------------------------------ J i 1 M 51 -01130 -0 20 -3' 6-0" j j GRASS EXISTING i N I DRIVE WAY j j ------ ------ _._.------ _._. P.__._._._._.— _._._._------ - EXISTING SIDE WALK EXISTING DRIVEWAY oBA � G fi-.. SITE PLAIN 24 FORTH SCALE: 1/8 =1 —Off �.n JACKIE HONG LAM RESIDENCE 2513 W__ KNOX AVE SANTA ANA, CA 9270 W. WARNE:R AVE W K NO X AN (E SEN W MANLY AVE ROWLAND AVE TI'CAARDLER AVEW. SEGERSTORM AVE v__l c I ro40 I TY MA 'I ,V 3 d ti x. Ile ya EXISTING MASTER BEDROOM 01 BATTERY SD EXISTING DWELLING %u Z NEW ADDITION a co w ,_D� �0 6 a � 1' 6' cc' NEW CONC. LANDING NEW 3/4' N 2 •.,.1 r -`- ..-. HOSE BIBB a 4 X 4 HDR. G.F.I EXISTING WINDOW - TO BE CLOSED EXISTING LIVING ROOM .s (D EXISTING BATH � '' BATTERY SD EXISTING 22'X30' ATTIC ACESS Ld EXISTING= — BATH — — ENTRY I BATTERY BATTERY I EXISTING { BED ROOM 02 EXISTING BED ROOM 03 FLOOR PLA V O ■SCALE: 2 Jtv WD 4'4 SLID 0 W,P DR ?(PR) 6$ AL/TEMP. GL2'' G.F.) o _ i G.F.I x t° F .C.I f t G.F.! 4 I NEW°0 KITCHEN 17' X 19.5' �' L_LL a G.F]=( r ENERGY LIGHT i A.F.C.! 110V I _ - NEW 22'X30' A 3 �`C"I6 ATTIC ACESS r---------- IVA" 6'4' NEW OPENING r 4 X 12 HDR. r r r - ----- EXISTING KITCHEN TO BE REMOVE r r EXISTING KITCHEN i TO BE REMODELED TO NEW FAMILY ROOM BATTERY SD EXISTING 02 CAR GARAGE 0 LANDING MUST BE NO MORE THAN I INCH LOWER THAN DOORWAY THRESHOD. MAXIMUM LANDING SLOPE NOT TO EXCEED 2%, LEGEND PROJECT DIRECTORY DETAIL REFERENCE OWNER DUC K LAM A �--- DETAIL NUMBER JACKIE HONG LAM OI SHEET NUMBER ADDRESS: 2513 W KNOX AVE SANTA ANA CA 92704 SECTION REFERENCE TEL: (714) 957-2830 A SECTION NUMBER DESIGNER: TONY VO ®1 13075 MAGNOLIA ST. �---- SHEET NUMBER GARDEN GROVE CA 92844 TEL: (714) 925-3145 DOUBLE STANDARD OUTLET FAX: (714) 637-4188 STANDARD SWITCH BATTERY NEW BATTERY SMOKE DETECTOR (EXIST. ROOM) BUILDING CODE SD 110V 110V HARD WIRED SMOKE DETECTOR LEGAL JURISDICTION: CITY OF SANTA ANACALIFOR NIA SD WITH BACK-UP BATTERY (NEW ROOM) APPLICABLE CODES: 2001 FOR ALL BELOW W.P. WATER PROOF CALIFORNIA BUILDING CODE CALIFORNIA MECHANICAL CODE G. F.I GROUND FAULT INTERUPTER CALIFORNIA PLUMBING CODE A. F. C.I ARCH- FAULT CIRCUIT INTERUPTER CALIFORNIA FIRE CODE CALIFORNIA ELECTRICAL CODE EXHAUST FAN 5 AIR CHANGES PER HOUR CALIFORNIA ENERGY CODE - LIGHT FIXTURE NEW WALL SHEET INDEX. EXISTING WALL SHT 01: GENERAL NOTES -SITE PLAN AND FLOOR PLAN EXIST. WALL TO BE REMOVED SHT 02: ROOF PLAN -FOUNDATION PLAN & NOTES NEW 6' HIGH BRICK WALL SHT 03: ELEVATION PLAN AND SECTIONS SHT 04: DETAILS WALL TO BE FILLED SHT 05: TITLE 24 �► INDICATES SHEAR WALL TYPE AND LOCATION EXISTING 22'X30' - - - ATTIC ACESS IG—_—�j 54' SETBACK FROM PROPERTY LINE 3'-0' MIN. NEW CONC. LANDING FAIIIIIIIIIIIIIII SEPIt i 2005 _a 0 Lu z City of Santa Ana PROJECT SUMMARY LEGAL DESCRIPTION: ASSESSOR'S PARCEL NUMBER: 412-324-12 TRACK: 8342 LOT: 33 ZONE: RI CONSTRUCTION TYPE: VN TOTAL LOT AREA: t6,050 S.F EXISTING LIVING AREA: 1,367 S.F. EXISTING 2 CAR GARAGE AREA: 483 S.F TOTAL COVERED EXISTING AREA: 1,850 S.F SCOPE OF WORK ADD NEW KITCHEN ROOM EXISTING KITCHEN ROOM TO BE REMODELED TO FAMILY ROOM AREA PROPOSED ROOM ADDITION 01 NEW KITCHEN ROOM ±326 S.F TOTAL PROPOSED ROOM ADDITION AREA: ±326 S.F TOTAL LIVING AREA (EXISTING+PROPOSED): 1,367+326 = 1,693 S.F TOTAL LOT COVERED AREA (EXIST"+PROPOSED): 1,850 +326 = 2,176 S.F TOTAL PERCENT LOT COVERED AREA: 2,176/6050 = 36 % I r LU N O a� QN FL LO Z z r <� z CCD 00 co < < 0 0 z > 0 cv 0 Q 0 d- � r" LLJ r-) �_ r /Iy DRAWN BY: TONY VO CHECKED BY: DATE: AUG 05, 2005 SCALE: PER PLAN JOB NO: SHEET 1 of 5 PLAN NO.2R REVISION I DATE EVICTIKV1 MAIM I lkt(' KICIA1 AnnITInki ROOF& FRAMING PLAN. NORTH SCALE: 1/4"=1'_011 Roof Covering #15 lbs. of felt over 1/2 OSB plywood Nailing schedule 6". 611. 10" Panel span rating: 24 Finishing by roof material-eaglelite roof tile 5.7 lbs W/30 lbs felt underlayment as minimum typ. ICBO: 4660 All lumber are Douglas Fir -Larch. #2 unless note All nailing are Eld, 16d common nails Galvanized sheet metal (28 gauge min.) roof valley flashing is required. Flat roof area has 1/4" slope for drainage w/ felt hot mopped between or build up system Build up system: 2 layers #15 base sheet w/ cold apply & finished w/90 lbs. cap sheet Roof finishing matches existing style and color EXISTING DWELLING A 11 YA FINISH SCHEDULE 04 POST --\ NEW CONC. LANDING\ /-'X' "" 3 4 04 POST FLOOR BASE WALLS CEILING HD5A r\L H05A V-HD5A cm CIO CL 5� 00 00 CEILING ROOM NAMES HEIGHT REMARKS 5/8 D. A.B. 12" L. 024' D.C. MAX NEW KITCHEN EMBEDDED MIN. 7" INTO CONCRETE W/ 2- X 2' X 3/16 WASHER & NUTS I NEW DINING AREA V_0" oo NEW FAMILY ROOM V-0" Ox EXISTING LIVING ROOM & HALL V-00 el— 7­7 3 EXISTING MASTER BEDROOM 01 6-0" EXISTING BEDROOM 02 V-0. MIN. 3 1/2 CONCRETE SLAB\ X� 9 EXISTING BEDROOM 03 8!-0" 0 2500 PSI 0 28 DAYS USE 04 POST TYPE V CEMENT REINFORCING EXISTING BATHROOM 01 STEEL GRADE 40 OVER EXISTING BATHROOM 02 6' — 10" X 10" WWM 2" SAND 3'-0MIN. MIN. 6 MIL VISQUEEN (TYP) NEW CONC. I 4X4 POST -\ LANDING DOOR SCHEDULE #4 REBAR, 24" L. 024" D.C. O MAX. EMBEDDED MIN. 6' INTO EXISTING 0 DOOR SIZE FRAME J4 DOOR DESCRIPTION FOOTING (DRILLED W/EPDXY RIAL REMARKS OR APPROVED SIMPSON MATE S.E.T. (TYP) r-= 0 WIDTH HEIGHT THICKNESS FINISH I n 04 POST < 1 7-8" 6-8" 13/4 EXTERNAL DOOR WOOD SEE ELEVATION Uj 2 7'-0"(PAIR) 6-8" 2" ALJEMP. GLZ AL SEE ELEVATION EXISTING —3 LIVING ROOM 4 5 0 6 7 LU 8 9 Z WINDOW SCHEDULE, EXISTING KITCHEN TO BE REMODELED WINDOWSIZE GLZ TO NEW FAMILY ROOM WINDOW DESCRIPTION AREA REMARKS WIDTH HEIGHT GLZ THIK (S.F.) A 4'-0" 4!q DBL. AL. SLD. 2 LITES 16 SEE ELEVATION B V-17 6-V DBL. AL. SILD, 2 LITES 30 SEE ELEVATION C D E FOUNDATKAO."J"N PLAN - SCALE: 1/4"=10-0v' Shear Wall Schedule Sill Attachment Allowable Sher @ Slab Floor @ Plywood Floor Expanded Metal, or woven wire lath and 70 porliand cement plaster w/ 11 ga. Staples @ 180 plf 5/8" @ 4&' 16d @ 8" O.C. 6' O.C. (4) 3/8" CDX plywood (24/0) or 0813 w/ 8d nails 260 plf 5/8" @ 32' 16d @ 6" O.C. @ 6-6-12 520 pif * 5/8" @ 16' 16d @ 3" O.C. A 1/2" CDX plywood (24/0) or 088 w/ 8d nails 380 plf" 5/8- @ 24!' 16d @ N'O.C. @ 4-4-12 760 pff . 5/8" @ 16" 16d @ 2" O.C. A43/8" CDX plywood (24/0) or OSB wt 8d nails 490 plf * 5/8- @ 16" @ 3-3-12 980 plf * 3/4" @ 16" 16d @ 3" O.C. 3/8" CDX plywood (24/0) or OSB w/ 8d nails 640 plf * 5/8" 0 16" 16d @ 2-1/2" O.C. @ 2-2-12 1280 plf 3/4' j 16" A 10 Structural plywood (24/0) or 0SI3 w/ I Od 665 pif * 1 518" @ 16, nails @ 3-3-12 1/2" Structural plywood (24/0) or OSB wt 10d 870 plf * 1 3/4" @ 16" 1 L nails @ 2-2-12 ATTIC VENT CALCULATIONS: Room Addition : 326S.F. 326/150 = 2.17 S.F. Ventilation Provide: 12" Dia. = 0.78 S.F. 14"x18" Attic Vent = 1.75 S.F. TOTAL = 2.53 S.F. NAILING SHEDULE (CBC TABLE 23-11-B-1) JOIST TO SILL OR GIRDER, TOE NAIL 3-8d BRIDGING TO JOIST, TOENAIL EACH END 2-8d SOLE PLATE TO JOIST OR BLOCKING, TYPICAL FACE NAIL 16d@16" O.0 SOLE PLATE TO JOIST OR BLOCKING, AT BRACED WALL PANELS 3-16d per 16" TOP PLATE TO STUD, END NAIL 2-16d STUD TO SOLE PLATE 4-8d, TOENAIL, OR 2-16d, END NAIL DOUBLE STUDS, FACE NAIL 16d @ 24- O.0 DOUBLE TOP PLATES, TYPICAL FACE NAIL 16d @ 16" O,C DOUBLE TOP PLATES, LAP SPLICE 8-16d BLOCKING BETWEEN JOISTS TO RAFTERS TO TOP PLATE, TOENAIL 3-8d RIM JOIST TO TOP PLATE, TOENAIL 8d @ 6" O.C. TOP PLATES, LAPS AND INTERSECTIONS, FACE NAIL 2-16d CEILING JOISTS TO PLATE, TOENAIL 3-8d CONTINUOUS HEADER TO STUD, TOENAIL 4-8d CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL 3-16d CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL 3-16d RAFTER TO PLATE, FACE NAIL 3-8d BUILT-UP CORNER STUDS 16d @ 24" O.C. 2" PLANKS 2-16d @ EACH BEARING NOTES: Doors & Windows: All windows & sliding doors are aluminum frame - slider 0.75 NFRC U-value, 1/2" air space, dual glazed w/ safety glazing (tempered) 44" max. high above finishing floor Sliding glass doors have category it classification per CBC Chapter 24 and UBC Std, 24-2 All new windows to be matched with the existing. Safety glazing is required at wardrobe door. Lumber: Used Douglas Fir -Larch #2 All work to be comply with: 1994 UBC, NEC, UPC & Local Code Misc. SD Smoke detector w/ battery HVAC connecting to the exist'g unit w/ flexible duct U.L. marked for all fixture to be used, All plumbing wall to be at 2"x 6" construction Exterior stucco match the existing style & color Provide water-resistant gypsum backing board as a base for tile or wall panels for tub or shower enclosures or water closet compartment walls. Showers shall be finished 70" above drain with ceramic tile. Anti -scalding tub/shower valves required. Framing notes: Provide double top plate w/ min. 48" lap splices. Fire blocking, verticle or horizontal, shall conform to Sec. 708.2 Where top plates or sole plates are cut for pipes, a metal tie min. 0.058" thick and 1 Y2 wide shall be fastened to each plate across and to each side the opening with not less than 6-16d nails. C) aE M C%j x r� 0 Z Z < LO Z LIJ 04 < co 7' < �0 I z0� Lij > Ll < ry In Z LjJ 0 ry < DRAWN BY: TONY VO CHECKED BY: DATE: AUG 05, 2005 SCALE: PER PLAN JOB NO: SHEET 2 OF 5 PLAN NO, 2R REVISION DATE izzL co GAUGE. METAL, ROOF TO W FLASHING. — al NEW CRICKET MIN. SLOPE 1/4" PER FT. ml 1�-�ul LT �- -u E) sL WINDOW Z(E) SL WINDOW STUCCO OVER THE I' m WALL-/ L G.F.I. EXISTING 3/4" \-NEWTEMPERED Z(E.)STUCC0 COVERING OVER WEATHER-RESITIVE BARRIER Wp HOSE BIBB SLD. DOOR 2-LAYER 15# FELT TO MATCH EXISTING ROOM ADDITION EXISTING DWELLING A L \-NEW 1418" ATTIC VENT 00 Q 11 �\ (N) SL WINDOW jh,!l 7 7 7111 !! �, Za 9 COON • N 16M &14W.Al III =M FL -A NE im ROOF MATERIAL-EAGLELITE ROOF TILE ICBO 4660 v12" DIA. ATTIC TURBINE VENT. 5.7 LBS W/30 LEIS FELT UNDERLAYMENT -METAL CRICKET FLASHING AS MINIMUM TYP. ff --- = EXISTING 1424" AMC VENT IF\ T(E) SL. WINDOW Z(E) SL WINDOW WINDOW (E) SL. WINDOW Y8 STUCCO OVER THE EXTERNAL WALL (E.)FIRE PLACE (E.)STUCC0 COVERING OVER WEATHER-RESITIVE BARRIER 2-LAYER 15# FELT TO MATCH EXISTING,, , A m m 1-ri AN L I r-%11^'rlL I 1,% r%% 1 Ir-1 I IL lJON ELEVATION VIEW ,WEST SCALE: 11/4"=V-011 2X8 RIDGE - 2x BLOCKING - 2x6 RR 0 16" O.0 - 1/2' PLY SHEATING COX INDEX 24/0 TYP. - NAILS 8d-6ft, 12" O.0 4r,-REMOVE EXIST. OVER HANG tv- WHERE OCCURS EXISTING -J STRUCTURE vwv EXISTING STRUCTURE 4, ISTING KITCHEN CONVERT TO AMILY ROOM SAME LEVEL EXIST. FINISH LEVEL R-30 INSULATIONS -j 2x8 CEILING JOISTS @ 16" O.C- 12 HEADER NEW KITCHEN ROOM NEW 3-1/2 CONC. SLAB-, 9 EXISTING DWELLING i ROOM ADDITION T SECTION AA SCALE: 1/4"=1'-0" m R-13 INSULATION i4-- NAT. GRADE EAST E L EV SCALE: 11/4"=1'-011 GAUGE WJ26 METAL ROOF TO W FLASHING. R- 13 INSULATIONS q4 (E) ROOF METAL CRICKET R-EXISTING 1424" ATTIC VENT z Z( (E) SL WINDOW E) SL. WINDOW v (E.)STUCC0 ZNEW DOOR EXISTING DWELLING ROOM ADDITION T ATION VIEW 4) (E)ROOF NEW CRICKET MIN SLOPE 1/4- PER FT R-30 INSULATIONS --1 1, - . 2x8 CEILING JOISTS 0 16" O.0 J NEW EXISTING KITCHEN ROOM LIVING ROOM R-13 INSULATIONS NEW 3-1/2 CONIC. SLAB-� Al SCALE: 1/4"=l'-O" EXISTING DWELLING Z(E) SL WINDOW ROOF MATERIAL-EAGLELITE ROOF TILE ICBO 4660 5.7 LBS W/30 LBS FELT UNDERLAYMENT AS MINIMUM TYP. cn L- h STUCCO OVER THE EXTERNAL WALL COVERING OVER WEATHER-RESITIVE BARRIER 2-LAYER 15j FELT TO MATCH EXISTING C>CD Q�oco 0 MLO Z Lo Z u-j C14 < cn 00 cn or) < Ln < 0 > 0 < rY (D 0 ry < L'j DRAWN BY: TONY VO CHECKED BY: DATE: AUG 05,2005 SCALE: PER PLAN JOB NO: SHEET 30F5 PLAN NO. 2R NOTE: TYPICAL RADIANT 5/8 DRYWALL -- - ----- 7/8" STUCCO OVER BARRIER FOR T-24 TREATED SILL W WIRE MESH NEW ROOF AREA ANCHOR BOLTS X 1528" " LONG AND 2-LAYER FELT # 15 PAPER BACKING 4X 12 BEAM @ 24" O.C. U.N.O. W/ 2X2X3/16 WASHER 7" EMBEDDED INTO CONCRETE - -SHEAR WALL 24" O.C. & 12" FROM ENDS WHERE OCCURS SIMPSON MSTA 24 MST27 2X STUDS 4$" O.C. 3 1/2" CONC. SLAB W/ W/ SIMPSON NAILS 6X6 / 10-10 EWWM 00/ 16 O.C. 2" SAND FILL VISQUEEN O/ 2 SAND WEEP O W/ ROOF HEATING M�N. s • SCREED. SIMPSON EPC END 4X4 POST GRD. e POST CAP WOOD , ::: 4 SEE PLAN TOE NAILS -2X RIDGE BOARD -2X METAL HANGER W/ JOIST HANGER NAILS ♦.. ..y ..•�... r #4 REBAR 1 TOP 1 BOTTOM ; , R-13 2x ROOF RAFTER INSULATION Q 16" O.C. 12" 17 BM. TO POST CONN. PER PLAN S EXTERIOR FOOTING 9 RIDGE DETAIL 5 N.T.S. N.T.S. N.T.S. 1. PROVIDE MIN.4 BAR 6'-0" I LONG, 3" TO " FROM THE TOP OF THE FOUNDATION CENTERED AT "HD". (BEND REBAR AT CORNER) NOTES: — DEEPEN FOOTING AS REQ'D. NEW FOUNDATION EXIST'G FOUNDATION HDR PER PLAN TO ACHIEVE le + 4" REFER TO MANUFACTURER .- 4X4 BLKG HDR.) r SPECS. FOR INSTALLATION MIN. 2" OF CONCRETE COVER f u (E.N P) �VA L . as TO WOOD MEMBER EXISTING WALL { - MIN. DIST. TO CORNER #4 REBAR, 24 L 0 24 O.C. \ / 1 SHEARWALL 4 SHOULD BE 5" MAX. TIED AND EMBEDDED CLEAN AND ROUGHEN EXIST'G / t PER PLAN MIN. 6" INTO EXISTING FOOTING — MIN. Vc = 2500 psi (U.N.O.) CON. SURFACE BEFORE — SEE PLANS FOR HOLDOWN TYPES. 3 1/2" CONCRETE SLAB PLACING NEW CONCRETE 4X4 SILL 4X4 LKG(AUSILL) 8" MIN PER PLAN DRILL 3/4" 0 X 8" @ 45' / / Li (E.N.PLY.) IN.5 HOLE AND SET #4 @ 24" TO CORNER de O.C. PER PLAN t \ t a• . ,, t / CS16 ENTIRE LENGTH HD INSTALLATION z' • <, < : ' — `' BETWEEN WALLS • .4.7 SIMPSON HOLDOWN de le ANCHOR DIA. AND TYPE POST MIN. HD-5A 1 374 20 5/8" DIA SSTB24 4X4 OD Q SSTB BOLT r4 1 MIN. SHEARWALL WIDTH (W=Hj2) d D1? HOLDOWN INSTALLATION 14 DOWEL CONNECTION10 SHEARWALL DETAIL N.T.S. N.T.S. N.T.S. 1. NOTCH DEPTH & BORED HOLD d SEE TABLE BELOW. 2. STUD 3. SILL PLATE 4. HOLE EDGE DISTANCE 5/8" MIN. DOUBLE TOP PLATE 1 CRIPPLE BQ° Y AV 4 L 2 4 i 3i d MIN. I INV tT r� BORED HOLES STUD SIZE EXTERIOR & G BEARING I NON- WALLSO . 20 1 7/16" 12 1/8" 2x6 2 3/16" 3 5f 16" 2-20 2 1/8" 2 1/6 2-2x6 3 5/16" 3 5/16" NOTCH DEPTH STUD SIZE EXTERIOR do BALLSG BEARING WALLS 20 7 8" 1 7/16" 2x6 1 .3 8" 2 3 16" :AkJkl17P D TO SUPPORT HEADER MIN. SHEARWALL WIDTH (W=H/2) -4X HEADER SEE PLAN 3-16 d NAILS FOR SILL 2X TRIMMER (2-2X TRIMMER T OPENING WIDER THAN 6'-O") NAILS FOR 4X HEADER EXISTING ROOFING STRUCTURE EXISTING STRUCTURE EXISTING E.N NEW 2x6 R.R @16" O.0 1/2" PLY .SHEATHING CDX INDEX 24/0 TYP. NAILS 8d-6", 12" O.0 16d-8"O.0 E.N REMOVE EXIST. OVER HANG WHERE OCCURS r `J NEW 2x8 C.J @16" O.0 R-30 INSULATION 16d-8" O.C. A35 @ 24" O.0 2 x 6 CONT. WITH 16d 0 16" Q.0 SIMPSON "A 35" 0. 16" O.0 12 B.N 41 2x6 SOLID BLK'G BEVEL TOP FOR PLYWOOD NAILING 4"x 12" VENT 0 4" O.0 WITH 1 /4 SCREEN B.N + + i 1 "x 2" FLASHING 5 -16d NEW ROOF MATERIAL-EAGLELITE ROOF TILE ICBO 4660 - 5.7 LBS W/30 LBS FELT UNDERLAYMENT AS MINIMUM TYP. -1/2" PLY SHEATHING CDX INDEX 24/0 TYP. NAILS 8d-6", 12" O.0 2x6 RR 0 16" O.0 00-0 t mw 2x6 FASCIA EACH END E TYPE "X" CEILING GYPSUM BOARD 2x4 DBL TOP PLATES (7" O.0 NAILING) R-13 INSULATION R-3O INSULATION 2x4 STUD @ 16 O.0 2x8 CEILING JOIST @ 16" O.0 7/8" STUCCO OVER WIRE MESH 2x6 BLOCKING & 2-LAYER FELT #15 PAPER BACKING PLYWOOD SHEAR PANEL WHERE OCCURS I 5/8" GYP. BOARD (8" O.0 NAILING) STUDS E n1815 STUD NOTCHING/BORING LIMITS 11 WALL FRAMING 7 WALL DETAIL 2 N.T.S. N.T.S. N.T.S. 1— NOTCH IN PLATE 2- 1 3/4" MAX. IF BORED HOLI EXCEED 1 3/4" IN 2x4 TOP 1 2 PLATE OR 2 3/4" IN 2x6 TOP PLATE, STRAP E/S OF 3" MAX. PLATE W/ITEM #3 BELOW 3— SIMPSON CS16x14" LONG 1/2 DEP < METAL STRAP, TYPICAL @ EACH PLATE CUT W/(6) 16d's 0 EACH SIDE. ' 4- PIPE WHERE OCCURS 5 4 3 4 5- TOP PLATES/SILL PLATES 6- ANCHOR BOLTS PER PLANS 5 7- LOCATE ANCHOR BOLT 5" n7 (3) rl MIN. 9" MAX. AWAY FROM NOTCH OR END OF PLATE typ NOTE: -IF NOTCH OR HOLE EXCEEDS s 50% OF TOP PLATE WIDTH, 2X4 STUDS USE SIMPSON ST6224, STAGGERED 0 E/S OF PLATES. -USE SIMPSON NS AS NEEDED 1 PIPING THRU PLATE FRAMING 12 SPLICE DETAIL @ TOP PLATE N.T.S. N.T.S. 8d- NAILS 6" O.0 NEW ROOF SHEATING 8d-E NAILS RAFTERS W/ (2) B.N. 4" O.0 16d TOE -NAILS TO LEDGER 2X4 STUDS 0 16" O.0 CONT. 2X6 ��= (CRIPPLE WALL) LEDGER W j 16d ® 16" O.C. 1/2- PLYWOOD TO BLOCKING BELOW CDX INDEX SOLID 2x BLOCKING 8d-E NAILS 4" O.C-< EXISTING ROOF FRAMING 20 DBL TOP PLATES ---' " 2X4 STUDS 0 16" O.C--� R-13 INSULATION --- EXTERIOR - RAKE DETAIL 8 4 N.T.S. N.T.S. 1/2" PLY SHEATHIN CDX INDEX 24/0 TYP. NAILS 8d-6", 12" O.0 I 2X6 RR @16" O.C. .d Mm c e tAAA ttt ttt+rttt R-30INSULATION NEW 2x8 C.J @16" O.0 - 2x BLOCKING 0 24" O.C.- ROOM Kl REVISION DATE �r- �C Q 'o O � Yz `zti N Q FW— cn W N (it Q �- {C U ,I � W 0 O In N cy) c) Ir) t` w o . C DRAWN BY: TONY VO CHECKED BY: DATE: AUG 05, 2005 SCALE: PER PLAN JOB NO: SHEET 4 OF PLAN NO.2R Alk General Notes 1. The general contractor shall verify all dimensions and conditions at site. Any discrepancy found shall be reported to the Architect or Engineer. 2. All work shall conform to the minimum standards of the 2001 edition of the Uniform Building Code. 3. Structural changes made shall be submitted to the Engineer for review and approval. 4. Portions of construction not covered by structural design shall be constructed per person 2326 of the U.B.C.. 5. The general contractor shall be responsible for adequacy and safety erections bracing, shoring and temporary supports. Foundation & Site work 1 Design of foundation is based on clay, sandy clay, silty clay and calyey silt with alldwable bearing value of 1000 psf per table 18-1 -A of U.B.C.. 2. Contractor shall verify type of soil on site. He shall inform the Engineer if soil on site is inferior than the assumed soil type. 3. Soils with an expansion index greater than 20 shall not be used as fill supporting foundation of structure. 4. Fills and back fills shall be compacted to 90 % of maximum density. 5. The contractor shall be responsible for all shoring and bracing necessary to support cut and/or fill banks during excavation, and forming and placement of concrete 6. Concrete slab shall be 4" thick with 6" x 6" - #10 / #10 welded wire mesh over 1" sand over 6 mil visqueen over 1" sand. 7. All hold down anchors and post bases shall be tied into place prior to foundation inspection. I I I w%-% tl r% 6- 1 . All wood bearing on concrete or masonry shall be pressure treated Douglas Fir or Redwood. 2. Structural members shall not be cut nor notched without the approval of the Engineer. 3. Metal anchors, fasteners, and connectors shall be Simpson Strong -Tie connectors. Substitutions must be approved by the Engineer. 4. All structural lumber shall be Douglas Fir -Larch with 19 % maximum moisture content. 5. Unless otherwise noted, use the following lumber grades: 2 x 4 studs Construction of Stud Grade 2 x 6 studs No. 2 2 x studs No. 2 4 x 10 beams and smaller No. 2 4 x 12 beams and larger No. 1 6 x studs No. I Posts and columns No. 1 6. All nailing shall be per table I-Q of U.B.C. unless otherwise noted. 7. Plywood floor and roof sheathing shall be laid Continuous over two or more spans with face grain perpendicular to support. Stagger all plywood panels a minimum of 4 ft.. Nailing shall be inspected before covering. 8. Plywood sheathing exposed on the underside shall be bonded With exterior glue. 9. Roof sheathing shall be 1/2" CDX plywood (P.i.24/0) nailed with 8d @ 6" at boundaries and edges; 8d @ 10" field nailing. 10, Floor sheathing shall be 5/8" (minimum) T & G (P. 1. 32/16) nailed with 10d @ 6" at boundaries and edges; 110d @ 10" field nailing. 11. Wall studs shall be continuous between points of lateral support (balloon fanned) and not interrupted by horizontal plates. Such conditions are normally found on the walls found on the walls at gable end of vaulted ceiling and walls around stairs. 12. All bearing walls on a wood floor shall be supported with double joists or solid blocking unless noted otherwise. 13. Apply shear wall plywood prior to all box -outs, fur -outs, soffits or any other framing that may interrupt continuity of the plywood shear wall. 14. Double top plate lap splice shall be minimum of 48" and unless noted other wise, shall be bailed together with a minimum of (8) 16d common nails per splice. Top plate breaks shall occur over a stud or post. 15. All hold downs shall be fastened to a 4 x 4 post minimum, unless noted otherwise. 16. All exterior walls and interior bearing walls shall be secured to foundation with 5/8" ? x 10" anchor bolts @ maximum spacing of 48" O.C. with S/16" x 2" x 2" bearing plates. Refer to shear wall schedule for anchor bolt size and spacing at shear walls. Structural and Miscellaneous Steel 1 All structural and miscellaneous steel shall conform to ASTM A-36 and shall be fabricated and erected in accordance with the latest edition of the A.I.S.C. Specification for the Design, Fabrication and Erection of Structural steel for Building. 2. Pipe columns shall conform to ASTM A-53, grade B. 3. Steel rubes shall conform to ASTM A-500, grade B. 4. Bolts shall conform to ASTM A-307. 5. Provide 3 inch minimum cover around all structural steel below grade. 6. All welding shall comply with A.W.S. Specifications and shall be done by certified welders. 7. All welding shall be done by electric are process with E70XX electrodes. 8. All Welding shall be done in the shop of a licensed fabricator. 9. Provide special inspection for all field welding. Manufactured Wood Products 1 All glued Laminated members shall be made of I - 1/2" Douglas Fir laminations, combination 24-F per AITF with the following allowable values: Fill = 2,400 psi Fv = 165 psi E = 1,800,000 psi 2. Glued laminated members shall be accompanied by a certified of inspection 3. All glulams shall have a standard camber unless noted otherwise. 4. Parallams shall be Parallarn PSL 2.0 E by Truss joist Macmillan with the following allowable values: Fb = 2,900 psi Fv = 290 psi E = 2,000,000 psi 5. Joists shall be TJI joists by Truss joists Macmillan and shall conform to NER 200. 6. Refer to Truss Joists Macmillan Specification for location and size of holes that maybe drilled through the web of TJ I joists. Concrete Mason 1. Concrete block units shall be grade N-1, light weight, conforming to ASTM C-90. Minimum compressive strength, fm = 1,500 psi. 2. Mortar shall be type M conforming to ASTM C-476. Minimum compressive strength, fc = 2,000 psi. 3. Grout shall conform to ASTM c-476. Minimum compressive strength, fc = 2,000 psi. 4. All walls below grade shall be waterproofed and positively drained. 5. Unless noted otherwise on the plans, special inspection is not required for masonry construction. Concrete Unless otherwise noted on the plans, concrete shall have a minimum compressive strength of 2,500 psi in 28 days. 2. Use type Cement. 1 Aggregate shall conform to ASTM C-33. Reinforcing Steel 1. Reinforcing steel shall be deformed steel conforming to the requirements of ASTM A-615 grade 40. 2. Minimum cover for cast in place concrete shall be as follows: a) Poured against earth 3 inches b) Walls exposed to weather: # 5 and smaller 2 inches # 6 and larger 1.5 inches 3. Bars shall be clean or rust, grease or other material likely to, impair bond. 4. Minimum lap of reinforcement shall be 40 bar diameters. Lap horizontal bars at corners and intersections. ll IPisi► --M (Page I of 3) CF-11 R Duc K Lam Project Tile 2513 W Knox Ave., Santa Ana, CA 92704 Project Address Tony Vo (714) 925-3145 Documentation Author Telephone Package D 8 Compliance Method (Package or Computer) Climate Zone 4 233= Date Building Permit # Plan check Date Field check Date Enforcement Agency Use Total Conditional Floor Area 326 ft.2 Average Ceiling Height 9 ft.2 Conditional Slab Floor Area 326 fil Building Type: x _Single Family Addition (Check one or more) Multi-Farriflly, Existing -Plus -Addition Front Orientation: South North / South)/ East / West All Orientations Number of Stories: 2r of Dwelling Units ril Floor Construction Type: ;luab Raised Floor (Circle one or both) RADIANT BARRIER (required in climate zones 2, 4, R-15) Required for this submittal X yes -no BUILDING ENVELOPE INSULATION - ------- ----- ­-­­-­­­-- ------ TIFrame Type! Cavity Sheathing 1 1 1 I Location/Comments Component Total Assembly wd = wood Insulation Insulation 1 (attic, garage, typical, Type I R-Value U-Factor I 1 I still = steel R-Value R-Value etc.) ­---11 WallWood R-13 R-1 3 1-EXTERIOR-WALLS-- Wall Roof Wood R-30 R-30 CEILING - ----------- Roof Floor Concrete Floor Slab Edge T- For prescriptive compliance. Total R-Value and Assembly U-Factor are not required for a wood -Framed wall that meets cavity R-Value insulation requirements for the Prescriptive Package. Fenestration Fenestration # /Type Poll Orientation Area (ft. 2) Fenestration U-Factor Fenestration SHGC Exterior Shading Att. Overhangs Fin Front SOUTH 40 0.40 0.35 SHADED Yes Front Left WEST 82 0.40 0.35 SHADED Yes Left Rear NORTH 132 0.40 0.35 SHADED Yes Rear Right EAST 50 0.40 0.35 SHADED 'Yes Right Skylight Skylight MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page I of 2) MFAR Note:Low rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimums component performance specification for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. -DESCRIPTION DESIGNER ENFORCEMENT Building Envelop a Measures: • § 150 (a): Minimum R-19 ceiling insulation. X § 150 (b): Loose fill insulation manufacturer's labeled R-Value. 150 (a): Minimum R-13 wall insulation in wood framed walls or equivalent U-Factor in metal frame walls (does Not apply to exterior mass walls) • § 150 (d): Minimum R-13 raised floor insulation in framed floors. § 150 (1): Slab edge insulation -water absorption rate no greater than 0.3 % water vapor transmission rate no greater than 2.0 perm / inch. § 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. X § 116-17: Fenestration Products, Exterior Doors, and Infiltration I Enfiltration Controls. X 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field-fabracated) have label with certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherwripped; all joints and penetrations caulked and sealed. § 150 (g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § ISO (f): Special infiltration installed to comply with § 151 meets Commission quality standards. § 150 (e): Installation of Fireplace, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closable metal or glass door. b. Outside air intake with damper and control. C. Flue damper and control. 2. No continuous burning gas pilot lights allowed. Space Condition, Water Heating and Plumbing System Measures: § 110-113: HVAC equipment, water heaters, shower heads, & faucets certified by the commission. § 150 (h): Heating and/or cooling loads calculated in accordance with ASRAE, SMAGNA or ACCA. § 150 (i): Setback thermostat on all applicable heating and/or cooling system. X § 150 & Pipe and tank insulation. X 1 . Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 ft. of pipes closest to water heater tank,non-recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-1 2 external insulation or R-16 combined intemallexternal insulation. 4. All buried or exposed piping insulated in recirulating sections of hot water systems. 5. Cooling system piping below 55* F insulated. Piping insulated between heating source and indirect hot water tank. CERTIFICATE OF COM PL IANCE RESID ENTIAA. (Page 2 of 3) CF-1 R Duc K Lam Aug 5, 2005 Project Tile Date HVAC SYSTEMS Note: Input hydronic or combined hydronic data under Water Heating Systems, except Design Heating Load. Heating Equipment Minimum Distribution Type Duct or Thermostat Heat Pump Type (furnace, heat, Efficiency and Location Piping Type Configuration pump, etc.) (AFUE or HSPF) (ducts, attic, etc.) R-Value (split or package) Existing FAU 111­1111 - ------- -- Cooling Equipment Minimum -- Duct - --------------- ------- Heat Pump Type (air conditioner, Efficiency Location Duct Thermostat Configuration heat, pump, evap cooling) (SEER) (attic, etc.) R-Value Type (split or package) Existing FAU STD DUCT 4.2 SETBACK SPLIT SEALED DUCTS and TXV'S (or Alternative Measu req f-1 Sealed Ducts (all, climate zones) (installer testing and certification and HERS Rafter or field verification required) Cl TXV's Commission approved equivalent, readily accessible (climate zones 2 and 8-15 only) (installer testing and certification and HERS Rafter or field verification required) OR El Alternative to Sealed Ducts and TXV's (see Package C or D Altemative Package Features for Project Climate Zone) Climate Zone Window SHGC Window U-Factor SEER Heating 8 0.35 0.4 (require vinyl frame doors & window) Water Heating Systems Water Distribution Number in Rated Input Tank Energy Factor Standby External Tank Heater Type Type System (kW or Bl Capacity or Recovery Loss Insulation (gallons) Efficiency R-Value GAS WATER HEATER GAS ONE 75 50 STD STD R-12 BLANKET For small gas storage water heaters (rated inputs of less than or equal to 75,000 Btli electric resistance, and heat pump water heaters, list Energy Factor. For Large Gas storage water heaters (rated input greater than 75,000 Btu/Hr), list rated input, Recovery Efficiency and Standby instantaneous gas water heaters, list rated input and recovery efficiency. SPECIAL FEATURES Package C and D: TXVs or Commission approved equivalent, Sealed Ducts, Radiant Barriers (see installation requirements for radiant barriers in Section 8.13 of the 1999 Residential Manual). Package C: thermal mass (thermal mass type, covering, thickness, and description). RB is required MANDATORY MEASURES CHECKLIST: RESIDENTIAL (Page 1 of 2) MF-I R Note:Low rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimums component performance specification for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or enter N/A if not applicable. DESCRIPTION DESIGNS ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (Continued) • § 150 (m): Ducts and Fans X All ducts and plenums installed, sealed and insulated to meet the requirement of the 1998 cmC Sections 601, 603, 604, and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct system that meets the applicable requirement of UL 181, UL 181 A, or UL 181 B. If mastic or tape is used to scale openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints mastic or tape is used to scale openings greater than 1/4 inch, the combination of mastic and either and scams of duct systems and their components shall be scaled with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan system have back draft or automatic dampers. 3. Gravity ventilation systems serving conditioned space have either automatic or readily accessible manually operated dampers. 114: Pool and Spa Heating Systems and Equipment. 1 Systems is certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no X continuously burning pilot. (Exception: Non -electrical cooking appliances with pilot < 150 Btul Lighting Measures: Ill 1: Luminaries for generaT-lighting in kitchen shall have lamps with an elficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. §150 (k) 2: Rooms with a shower or bathtub must have either at least one huminaire with lamps with an efficacy of 40 lumensAil or greater switched at the entrance to the room or one of the alternative to this X requirement allowed in § 150 (k) 2; and recessed ceiling fixture are IC (insulation cover) approved. (Page 3 of 3) CF-1 R COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsiblility. The undersigned recognize that compliance using duct sealing and TXVs (or Commission approved equivalent) requires installer testing and certification and field verification by an approved HERS ratter. Designer or Owner (per Business and Professions Code) Name: Duc K Lam Title/Firm: OWNER Address: 2513 W Knox Ave. Santa Ana, CA 92704 Telephone: (714) 957-2830 Lic. #: Duc K Lam (Signature) Q= (Date) Enforcement Agency Name: -- Title/Firm: --De, Address: 15S 15 &4 ctZ6 S-3 Documentation Author Name: --Tony vo Title/Firm: -- Drafting Service Address: 13075 MaQnolia St A A Garden Grove, CA 9284, Telephone: 714-925-3145 Tony Vo 08-30-05 (Signatu (Date) 00 LLJ f-) > 00 < X < 0 U Z Ln < < Cj Ln -Z LJ I ­- -1 <: < --i Z 0 0) 0 < CL LiJ 0 LLJ DRAWN BY: TONYVO CHECKED BY: DATE: AUG 05,2005 SCALE: PER PLAN JOB NO: SHEET 50F5 PLAN NO. 2R