HomeMy WebLinkAbout10149532.pdf2 3 1120 CDX PLYWOOD W/8d 6" /6" / 1 2"o, C, LIGHT TILE OVER I LAYER# 15 FELT R-30 BATT INSULATION 2-x 8' RAFTERS @ 16' 0, C, 2' x 6' C, J. @ 16" 0, C. 5-16d B, Nl Bd @ 6" 0, C, 2"X6" BLOCKING W/ A35 @EACH BLOCK ++ _j _j 1/2"PLYWD BLOCKED 2" X 6" C, J 2 16" 0, C, W/8d COMMON NAILS @ 6", 6" & 12" 0, C. A35 @ 24" O,C, 2"X4" TOP PLATE 2"X8" FASCIA W/ 2-16d @ R, R 2" X4` PLAT -DOBLE PLATE, LAP SPLICE 3-16d 2" XV STUDS @ 16 0, C -BLKG BEETWEEN C.J, & RAFTERS TO 3 112 STRUCTURAL PLYWOOD W/6'l/60/12' 0, C, 17Z -TOP PLATE T,N, 3-16d 8d COMMON NAILS -HEADER TO STUD 4-16d R-13 BATT INSULATION--/ -RAFTERS TO TOP PLATE 3-16d -RAFTERS TO C,J, 5-16d -DOUBLE PLATE 16d @ 16' 0, C, -ClJ. TO TOP PLATE T,N. 3-16d DETAIL # I (NOT TO SCALE) IRE BLOCK AS REQ'D 2 x 4 STUDS G, 16' OC R-13 INSULATION AT NEW EX'FERI[OR WALLS TYP, ONE POUR 5" CONC, SLAB 6X6- 6x6 WWM- 6 MILS MOISTURE BARRIER MEMBRANE 2'INCH, FILL SAND 5/8'O ANCHOR BOLT! EMBEDDED 7" MIN INTO THE CONCRETE FOUNDATION SPACED NOT MORE THAN 6 FEET APART 0-1 _Q__ W 1 2 1 x 2 t x 1/4' WASHERS (TYP) D 2 2 DETAIL# 11 (NOT TO SCALE) WEL DRILL 3/4' d HOLE INSERT # 4 BAR & FILL w/ EPDXY -TIE ADHESIVE, SIMPSON STRONG TIE, (BONDS HARDENED CONCRETE, FILLS CRACK WIDTHS FROM 3/16'TO 3/4', CAN BE USED AS SEALANT. MEETS ASTM C881-90 SPECIFICATION FOR TYPE 1, 11, IV, AND V GRADE 3 CLASS B AND C) DETAIL # 14 (NOT TO SCALE) l �� lllill!� 11111!'1111[5, VIM mum WEEP SCREED 2"X4" P,T, SILL PLATE nine- rnnr5r ONE POUR CONC, 4500 PSI #4 BAR- TOP & BOTTOM 26d @ 4' OC END OF SHEAR WALL BOUND NAILG, 10d @ 4' 0, Cr---- (N) SIMRGH 46-TF DETAIL #13 (NOT TO SCALE) 2XV STUD @ 16 RC, 2X8' FLOOR JOIST 16 0, C. SIMPl A35/eI6 0, C, I NEW 4 X 5/8'0 xiO'LONG @24' 0. C, (U, N, 0, 5 SHEAR PANEL PER PLAN (WHERE OCCURS) SIMPSON A35 24' 0. . C.� E, N, 1-1 < UNDIST, NAT, GRADE �D 7 2'X4 ' STUDS @ 16' D.C. R R @ 6' 0, C. 2x SILL PLATE W/16d NAILS @ 8' Tx RIM JOIST W/SIMR A35 @ 32- 0, C, (_R-19 )INSULATION EUWO0D SHTG, 2x 6 FLOOR JST, 1 11 , I M,, PLATE " T, , :�,:, " SILL PLATE W/ A, R� X 12" LG A. B, @ 4' -0` --= C, W/2, 5X2l 5X1/4' PL, WASHER 5/8'0 (TYP) cti o 2# 4 REBAR TOP & BOTTOM NEW FOOTING 6' 1219, DETAIL # 10 (NOT TO SCALE) X4 STUDS @ 16' O,C, 5/8' T&G PLWD,NAILED W/ 10d @ 6'110' FIELD (R-19 )INSULATION )2'1 X LOOR JST, 0 S RDER T, BLKG =�]i 4 X GIRDER w/ PC 44 4' X 4' PRESSURE TREATED P[1STX""1i`_._'1__'1 CB COLUMN BASE 91 X 9' CEMENT PIER 7777!� L_J 18' X 18' CONC, PAD -2'X4 " PLATE XG' SOLID kOCK'G 2'X BLOCK 7, DETAIL # 18 (NOT TO SCALE) DETAIL # 9 NOT TO SCALE) WIRE FENCE 66" BLOCK FENCE 66" HHEIGHT EIGHT -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - LANDSCAPE ------------------- ------- -------------- (E) DRIVEWAY (E) ONE CAR > GARAGE -9-1 209.19 Sq.Ft. LANDSCAPE (E) ONE STONY HOUSE! 824.05 Sq.0- N) ADDITION 482.39 Sq.Ft. 14' in i in BLOCK FENCE 66" HEIGHT 1/2'CDX PLWD,NALED W1 8d@10' FIELDS 6' EDGES 8 BEARING PLATE I 2x RIDGE BRD, OR 2 x RAFTER/2Xr2_1 2X6 RAFTERS J 6d PER RAFTER (TYP) U, 4 0, SPLICE DETAIL # 6 (NOT TO SCALE) DETAIL # 4 (NOT TO SCALE) 10 GENERAL NOTES I.- CONC. TO BE 2.500 P.S.I. @ 28 DAYS, TYPE V. 3.- SWINGING EXTERIOR WOOD DOORS TO BE EQUIPPED WITH A DEADBOLT & DEADLOCKING DEVICE, BATH KEY OPERATED FROM OUTSIDE. DEADBOLT TO HAVE HARDENED INSERT. 1"MIN THROW AND 5/8"EMBEDMENT INTO THE JAMB. 4- WOOD DOORS TO BE MIN, 1-3/8"THICK, DOORS WITH ACCESSIBLE PINS FROM EXTERIOR SHALL HAVE NON-REMOVEABLE PIN TYPE HINGES. DOOR STOPS TO BE ONE PIECE CONSTRUCTION OR JAINED BY A RABBET. 5.- SLIDING GLASS DOORS & WINDOWS SHALL BE CAPABLE OF WITHSTANDING BURGLARY RESISTANCE TEST SET FORTH BY LOCAL BUILDING AUTHORITY (L.E. SECT. 67906 & 67907 OF LA COUNTY BUILDING CODE), AND BEAR FORCED ENTRY RESISTANCE LABELS, GLASS IN ALL DOORS & GLAZED WALL PANELS SHALL CONFORM TO U.B.C. CHAPTER 24. 6.- DOORS & WINDOWS OPENING TO EXTERIOR OR TO AN UNCONDITIONED SPACE SHALL BE WEATHERTRIPPED TO LIMIT AIR INFILTRATION. ALL MFG. SLIDING GLASS DOORS AND WINDOWS SHALL MEET AIR INFILTRATIONS STANDARDS AS REQUIRED BY FEDERAL AND / OR LOCAL AUTHORITY, AND SHALL BE CERTIFIED AND LABELED THUS, 7.- INSULATION COMPLIANCE CARD SHALL BE POSTED IN A CONSPICUOUS LOCATION WITHIN THE BUILDING. 8.- INSPECTION IS REQUIRED FOR ALL IN -PLACE INTERIOR AND EXTERIOR BOTH OR WALLBOARD BEFORE ANY NAILING IS COVERED, 9.- SHOWER / TUB ENCLOSURES AND DOORS TO BE 3/16" FULLY TEMPERED, 1/4"LAMINATED OR APPROVER PLASTIC. ALL DOORS TO SWING OUT FROM SHOWER COMPARTMENT, GLASS ENCLOSURES SHALL BE LABELED CATEGORY 11, NET AREA OF SHOWER RECEPTOR SHALL BE NOT LESS THEN 1024 Sq. In. OF FLOOR AREA, AND ENCOMPASS A 30 INCH DIAMETER CIRCLE, 10.- WALLS AT SHOWERS AND TUBS WITH SHOWERS SHALL BE CEMENT PLASTER, TILE, OR APPROVER EQUAL TO 70 INCHES ABOVE DRAIN, MATERIALS OTHER THAN STRUCTURAL ELEMENTS SHALL BE MOISTURE RESISTANT. 11.- FOR SYSTEMS EXHAUSTING AIR FROM THE BUILDING TO BE EQUIPED WITH BACK DRAFT DAMPERS, AND PROVIDE FIVE (5) AIR CHANGES PER HOUR. 12.- HANDRAILS &GUARDRAILS TOLBE DESIGNED TO WITHSTAND 20 Lbs. OF LARERAL FORCE AT TOP OF RAIL, LAG SUPPORTS TO SALD BLOCKING OR APROVED FRAMING MEMBERS, RAILING WITH OPEN SIDES TO HAVE IMMEDIATE RAILS OR BALUSTRES @ 4 O,C. MAX, AND SO THAT A 4"SPHERE CANNOT PASS BETWEEN BALUSTRES. 13.- HANDRAILS IS TO BE 34" TO 38'ABOVE STAIR NOSING, 1'-1/2" CLEAR TO WALL, V- 1/4" TO 2' MAX CROSS SECTIONAL DIM. AND ENDS TURNED TO WALL OR NEWELL POST. 14.- APPROVED 110 VOLT SMOKE DETEDTORS WITH BATTERY BACK-UP SHALL INSTALLED IN ALL NEW & EXISTING BEDROOMS, HALLWAIS & ROOMS LEADING TO BEDROOMS AND AT TOP OF STAIRWAYS. SMOKE DETECTORS MAY BE BATTERY OPERATED AT EXISTING ROOMS, A 19 PROJECT NAME AND ADDRE55 LPV 2418 W LAVERNE AV. SANTA ANA CA. 92704 13 ALL IDEAS, DE51GN5AN'D PLAN5 MECHANICAL/ ELECTRICAL/PLUMBING INDICATED OR REPRE5ENTED E3YTHIS 4t,,__ 162. Elements of appliances with create a glow, spark, or flame shall DRAWING ARE THE PREOPERTY Or'"_ be located a minimum of 18" above garage floor ARCHITRAVE AND WERE CREATED AND DEVELOPED 167. All showers and tub -showers shall have either a pressure FOR U5E ON AND IN CONNECTION WITI- balance or a thermostatic mixing valve. TH15 5PECI f IC PROJECT, NONE Of 5UCH IDEAS, DE51GN5 OR PLANS 168. New or replacement water heaters shall be strapped to the wall SHALL BE USED BY OR DISCLOSED TO in two places. One in the upper 1/3 of the tank and one in the lower 1/3 of the tank. ANY OTHER PERSON, CORPORATION The lowerpoint shall be a minimum of 4 inches above the controls. OR f I RM FOR ANY PURPOSE WITHOUT THE WRITTEN PFRMI55ION Of 170. "Ducts shall be sized per Chapter 6 of the Mechanical Code" ARCHITRAVE. AREA CALCULATION f PARCELNo ........................................... 109-122-04 ZONING= ................. ................. ...... R-I LOT AREA=.......................................... 7508.19 SQ.FT. BUILDING ON LOT= ................................ TYPICAL HOUSE: (E) ONE STORY HOUSE (LIVABLE) 824.05 SQ.FT. (N) ADDITION= .... 482.39 SQ.FT. (E) PORCH= ...... 50.56 SQ.FT. (N) AD D I T 10 N = !.N_ So,FT. 0 0 rn G) rn Z M ATTIC VENTILATION ATTIC NEW AREA 482.39 Sq fT 1/150 OF AREA 3.21 Sq fT G 91 X 181/2 DORMER 2,75 Sq Ft PROVIDE (6) VENTS MIN, 3.3 Sq Ft AREA PROVIDED (6 DORMER) 3,3 Sq Ft AREA PROVIDED IS GREATER THAN REQ1D. UNDER FLOOR VENTILATION FLOOR AREA 482.-39 Sq fT 1/150 OF AREA 3,21 Sq fT 14' X 18'GI VENT 1.25 Sq Ft PROVIDE (3) GI MIN. 3, 75 Sq Ft OVVNER: f RANC15CO RODRIGUEZ AD 2418 LAVERNE AV. SANTA ANA CA. 92704 (N) ADDITION IN 15t FLOOR owner-------------------------------------- date R;vision 7 issue PLOT PLAN FRAMING PLAN DETAILS GENERAL NOTES AREA & VENTILATION CALCULATIONS SCALE: 1/8" = 1' ATE. Aug-1 5-05 AREA PROVIDED IS GREATER THAN REQ'D, UNDERGROUND UTILITIES SHALL BE REQUIRED FOR THIS PROJECT. 2.- TO PREPARE, THIS PROJECT WAS BASED IN 2001 CBC. 5HEET BY ALL DIMENSIONS AND EXISTING CONDITIONS TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION. f PJAV -Plot Plan-Aucj 1 5_3 %S\ 1 1 2 3 Il 5 m 7 10 11 PROJECT NAME AND ADDRESS A 0 1 30"x60"TUBSHOWER WITH A SMOOTH. HARD. NONARBSORBENT SURFACE AT 70" HIGH ABOVE THE DRAIN INLET OF THE SHOWER OR TUB/SHOWER COMBINATION. MATERIAL SHALL BE OF A TYPE NOT ADVERSELY AFFECTED BY MOISTYRE. THE FIXTURE MUST BE ACCESIBLE BY 12" X 12" PLUMBING ACCESS FROM OUTSIDE. THE WATER CLOSET IN TOILET MUST BE ABLE TO PROVIDE 1.6 GPF WITH A FRONT CLEARANCE OF 24" MIN. AND 30" MIN. IN WIDTH BETEEN OTHERS FIXTURES. F3-] PROVIDE SMOKE DETECTOR IN EACH SLEEPING ROOM AND AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCES TO ACH SEPARATE SLEEPING AREA AND IN EACH STORY OR BASEMENT AND IF PROXIMITY TO THE STAIRWAY. DETECTOR MUST RECEIVE POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH BATTERY BACKUP.EXCEPT THAT IN EXISTING BUILDING (NOT IN AN ADDITION), THEY MAY BE BATTERY OPERATED. FIRST STUD NOT BEHIND HEATER ENCIRCL TANK ONE FULL WRAP FROM FRONT AND BACK WITH PLUMBERS TAPE 4 PIECES TOTAL PLAN 3/4X24 GAUi PLUMBER- TAI (PERFORATI METAL STRA WATEf HEATEf ri m- I me, I ELECTRICAL LEGEND FLUORESCENT LIGHT CEILING LIGHT WALL BRACKET OUTLET $ SINGLE SWITCH ELECTRIC METER SMOKE DETECTOR HARDWIRED W/ BATTERY BK UP FLUORESCENT TYPE GENERAL LIGHTING MECHANICAL VENT, ALL RECEPTACLES/OUTLETS IN BEDROOM SHALL BE & F, C, I, ARC FAULT CIRCUIT INTERRUPTOR PROTECTION CEC 2001 SEC oln-10 elD" WOOD 1/4"X3"LAG STUD SCREW W/FLAT WASHE 12" MAX I" MIN FROM COMBUSTIBLE MATERIAL TYPICAL ATER HEATER FLEXIBLE WATER :ONNECTIDN IBLE GAS NNECTION WATER HEATER SHALL BE PROVIDED WITH TWO SEISMIC RAPS, 18" HIGH PLATFORM AND P&T SHALL BE RELIEF VALVE SHALL TERMINATE OUTSIDE CONCRET OR MASONRY WALL 1/4" EXP, ANCHORS W/2" MIM- EMBEDMENT DETAIL # 19 (NOT TO SCALE) MINERAL FIBER INSULATION (NOTE 2> Fill 11 i�� 111 11' T I 111RI F=Altl =116119A =&wpm RESILIENT CLIP AT/ 2'x4'STUDS AT 16'0c' EACH STUD OR RESILIENT CHANNELS -ONE SIDE I HOUR RATED LATH AND PLASTER OOR ONE LAYER OF 5/8"TYPE "X`GYPSUM BOARD EACH SIDE GENERAL NOTES FOR ONE HOUR FIRE RATING I. THE TYPE AND SPACING OF RESILIENT CHANNELS AND CLIPS AND THE ATTACHMENT OF GYPSUM BOARD OR LATH SHALL BE AS REQUIRED FOR FIRE RATINGS. 2. THE MINERAL FIBER INSULATION SHALL HAVE A THERMAL RESISTANCE R VALUE OF 11 OR GREATER AS DETERMINED BY FEDERAL SPECIFICATION RR-1-5218. 3. NO TEST IS ON FILE TO JUSTIFY AN STC 50 WITH ONE 5/8"TYPE "X"GYPSUM BOARD EACH SIDE. ALL BRACED WALL PANELS SHALL EXTEND TO THE ROOF. SHEARING AND SHALL BE ATTACHED TO PARALEL ROOF. RAFTERS OR BLOCKING ABOVE WITH FRAMING CLIPS (18 GAUGE MINIMUN) SPACED 24"O.C. WITH FOUR 8o NAILS PER LEG. (TOTAL EIGHT 80 NAILS PER CLIP) WOOD STRUCTURAL PANELS TO BE 1/2" (12.7 MM) NOMINAL STRUCTURAL I WOOD STRUCTURAL PANEL MIN 4'(1.2MM) WIDE AT EA.END OR AS NEAR ENDS AS POSSIBLE VVt8D NAILS AT 6"(1.52 MM) OR CENTER (EDGES) AND 12"(305 MM) ON CENTER (INTERMEDIATE FRAMING MEMBERS) OR 6- (152 MM) WHEN INTERMEDIATE FRAMING IS 24"(610 MM) 0. C. AT SHEAR WALL AREAS LEGEND EXISTING WALL AND FT'G 14 0 NEW WALL AND FTG 1 1 EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED DOOR SCHEDULE ) No SIZE MATERIAL REMARKS 2' -8'x 6-8" WOOD HOLLOW CORE INTERIOR 2 3'-0`x 6-8" WOOD HOLLOW CORE EXTERIOR INCLUDE TEMPERED GLASS WIND 3 6'-0'x 6-8' ALLUM/GLASS SLIDING DOOR TEMPERED GLASS 4 2' -0" x 6-8" WOOD HOLLOW CORE EXTERIOR DOOR INCLUDE VENTILATION NOTES. NEW WALL NOTE: UNDERFLOOR VENTILATION NOT LESS THAN 1/150 UNDER FLOOR AREA NOTE: BEARING WALLS STUDS CANNOT BE NOTCHED MORE THAN 25% OF THEIR WIDTH, BORED HOLES CANNOT HAVE A DIAMETER GREATER THAN 40% OF THE STUD WIDTH SW22 X7-4 (SIMPSON STRONG WALL PORTAL) NOTE: ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1?16" OVER SIZED NOTE: ALL DIAGRAM AND SHEARWALL NAILING SHALL UTILIZED COMMON NAILS OR GALVINED NOTE: ALL PLUMBING STUDS WALL 2"X6" SKETCH ROOF NOT TO 5CALF= SAlk ITA IN ANA CA. I A N FLOOR PLJAN SCALE WINDOW SCHEDULE No SIZE MATERIAL REMARKS 1 2' -0'x3' -0' ALLUM/GLASS SLIDING WINDOW TEMPERED S TEMPERED GLASS GLASS s A A 2 5'-O'x4'-O' ALLUM/GLASS SLIDING WINDOW GA L TEMPERED TEMPERED GLASS AS S 3 1' -6'x2' -0" ALLUM/GLASS SLIDING WINDOW TEMPERED GLASS 4 4' -0'x4' -0' ALLUM/GLASS SLIDING WINDOW TEMPERED GLASS L S, S 5 5' -0'x3' -0' ALLUM/GLASS SLIDING WINDOW TEMPERED GLASS ALL DIMENTIONS TO THE FIELD VERIFIED PRIOR TO CONSTRUCTION NOTES: A.- ALL WOOD CONSTRUCTION SHALL COMPLY WITH CODE SEC.2320 AND MINIMUM NAILING WITH CODE TABLE 23-11-13-1. i B.- PROVIDE MECHANICAL VENTILATION AT EXISTING BATHROOM C.- AT TOILETS, PROVIDE MIN. 30" WIDE SPACE WITH 24m IN FRONT OF TOILET D.- PROVIDE SMOKE DETECTOR IN EXISTING BEDROOM E.- PROVIDE HEATING TO COMPLY WITH CODE SEC. 310.11 ONE -HOUR -FIRE -RESISTIVE CONSTRUCTION ON THE GARAGE SIDE FOR WALLS, CEILINGS, POSTS AND BEAMS OF GARAGE ADJACENT TO OR SUPPORTING RESIDENTIAL USES, ALL ELEMENTS INSIDE THE GARAGE SUPPORTING STORIES ABOVE SHALL HAVE IHOURS PROTECTION, SELF -CLOSING, TIGHT -FITTING, SOLID WOOD 1 3/8 INCH THICK DOOR OR 20 MINUTE RATED DOOR AT OPENINGS TO DWELLING, (302,4) DOOR MAY SWING INTO THE GARAGE IF FLOOR OR LADING IN THE GARAGE IS NOT MORE THAN I LOWER THAN THE DOOR THRESHOLD( 1004, 9) , MST 37�, _1 F- — — - — — — — — — — — — — — — — — — — — — — — 13' -7' ry 3 ON AR GARAGE E_ f> (E) 'WALLS 0RY 0 BE 'REMOVED Ir 40,0 GAL WATER HEATER 'AMERICAN APLIANCEOGKrr- 454T! WITH GALV, CABINET INCLUDING COMBUSTION AIR VENTS PER UPC,CONCRET PAD AND 2' WIDE ACCESS DOOR,ALL WATER HEATERS SHALL BE ,/--PROVIDED WITH SEISMIC STRAPS AND SHALL BE VENTED OUTSAID, 2'y X 6 " L/PLU ING c L fz'�"A_l j IWALL/PLU I NO PROVIDE CLOTHES DRYER MOISTURE _EXHAUST DUCT (MIN, 4 INCH DIA,) TO THE OUTSIDE AND EQUIP WITH A B BACK -DRAFT DUMPER, eXHAUST DUCT 3 LENGHT IS LIMITED TO 14 FT WITH 2 ELBOWS (UMC 504,3) MS 37 �4/AIIJ L I M III 14"X 18" .UNDER PROVIDE FLUORESCENT T A 4 FLOOR VENT 1 LIGHTING MEANS 10 OR OTHER OBTAIN 4D U ---il8"X 24 11 — — — — — — — — — — — — — — — — LUMENS/WATT OR GRATE TE CRAWL HOLE W t1l E_ �14 tit? H_ A 2, e 24 ljCRA L HOLE 13'-2' I DINING ROOM If A, a-'- 3 9" x 18 I IIT - — — — — — �T PROVIDE A LANDING AT N KITCHEN EACH SLIDING DOORS, '--.-_THE < _(N) LANDING SHALL F- NOT BE MORE THAN F___ LIVING ROOM EXISTING WALL 80BELLOW THE FINISH TO BE REMOVED GFf GFI 0 ID El. I GF FLOOR ELEVATION 13 ALL RECEPTACLES/OUTLETS 1 I A: ME = 1 .11, - IN BEDROOM SHALL BE 018" 18� X �(, 30 Ir ul 4' A, F. C, I, ARC FAULT C ARW,-L L G CIRCUIT INTERRUPTORI MAX, 80 RISE __ PROTECTION CEC 2001 SEC' 21 r r) �j 11111 L=411 2' 0" X3' -o/,L=4 MIN, 9" RUN I 210-12 (Bj, * e__. 11 _5 u 2"X 6" 41 -1 WALL/PLUMBINC >1x 18# 9A�TIC EXISTING R, x-111 4 F3 TO BE MOVED (N)WINDO W VENT N T 2"X 6" SMOKE DETECTOR TOR 3 ROOM r 14' -0' x4' GFI/W WALL/PLUMBING W/BATTERY BACKUP 0I ifil L=411 Be I 24"x 3 0 & 14"X 18"UNDER S FLOOR VENT 24' x 30' MEmAIVICAL I J-61 N) W I ND\W 3' -6' CLE,�? AREA VEN I I� TICINO 3 1' -6- X, Tr __9 - mmm m "m "im" am v -,j F3111 3 if SMOKE DETECTOR S SMOKE DETCTOR ( (E)II (N Vkc WYBATTERY BACKUP A (N) 118"X 240 W/BATTERY BACKUP tCRAWL HOLE MAI EXISTING WALL -7- EXXISTI G WALL // MPROVIDE TO BE REMOVED T03BE REMOV FLUORESCENT LIGHTING G51/0 PROVIDE A LANDING AT OR OTHER EACH SLIDING DOORS, 7- OHAL /0 1 \X1 I MEANS TO OBTAIN 40 LUMENS/WATT OR GRATER MI1`4 _t 3' THE LANDING SHALL M. F3 NOT BE MORE THAN (E) BEDROOM L 8" BELLOW THE FINISH r ----- --- -S-M Di--\E- ­D ETEC-T EIR- F OORELEVATIDN IT-2 2'x 0 )�TT I C W ATTERY BACKUP s t) � CCES (N) 12 E ROOM OE EX I�ED 18S 3 A All ATTIC 1 VENT "�j S /7 18AWL X 24"OLE r CR H" SMO E DETECTO IBACKUP If J L 'S 7 13' 3' W/BATTE Y L— z__ _/_ _.z _/_ 1-.e v — — — — — — — — — — — — — — — _MS T_ _377` IE X ISTING LL if I 'TO BE REMOV 14') FLOOR 0 18UN VEND EM S"i ==7r MAX,8"RISE ALL RECEPTACLES/ OUTLETS I IL V I (N)WINDOW n2 'KI, LL-J_jll� t -, \ 4'- MIN, 9'RUN IN BEDROOM SHALL BE 5'--0' x4' -0' - - - - - - - A, F, C, 1, ARC FAULT =4v 18'X 24" L=40 WINDOW L=41 CIRCUIT INTERRUPTO CRAWL HOLE 5' -0' x3' -0' B PROTECTION CEC 2001 SEC 210-12 (B) OIL Ind C F f m 2418 LAVERNE AV. SANTA ANA CA. 92704 ALL IDEAS, DESIGNS AND PLANS INDICATED OR RffPRF5ENTED DYTH15 DRAWING ARE THE PREOPERTY Of ARCHITRAVE AND WERE CREATED AND DEVELOPED FOR USE ON AND IN CONNECTION WITt' TH15 SPECIFIC PROJECT. NONE Of SUCH IDEAS, DE51GN5 OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY OTHER PERSON, CORPORATION OR FIRM FOR ANY PURPOSE WITHOUT THE WRITTEN PERMISSION Of ARCHITRAVE. FW Nf- R: f RANCISCO RODRIGUEZ ADDP,7,_. F55: 2418 LAVERNE AV. SANTA ANA CA. 92704 (N) ADDITION IN 1.5t FLOOR owner — — — — — — — — — — — — — — — — — — — - "Islostye FLOOR PLAN SCALE: 114" 1 DATE:Au.,3,-I5-05 2 3-8d FINGER - EDGE NAILIN 2x FULL HT, STUDS @ 16" O/C 2Y,4 FLAT FINGER @ 34" O/C NOTCH INTO ROOF JST. W/ NAIL W 2-16d A35 @16 O.C. —2x BLKS @ 72" O/C W/ 3-16d TO FINGER & 2-16d TOE NAILS TO PLATE 2x BLOCKING- / 6d @ 4" O/C \\\2x 6.3 DETAIL # 5a (NOT TO SCALE) Sil 5 No Scale A35 @ Gable Stud @ 16" o Simpson Framing PI Model A35 @ 8"o.c Top plate to Rim J6 2- 1 6d End Nal Top Plate to Hold -Down Hardware where applicable sing See Framing & Foundation Plan for model and locations Son H 10-2 hear wall nails it wall schdule B.N. Roof Sheathing A Top Plates Od Nails @ 6" o.c. �(32 Structural Plywood Sill Plate [6d @6" ox. Ceiling Joist Toe Nails @ 6"o.c. nr Joist to Top Plate @ 16 o.c. No Scale 2" X COLLAR T I ES@ 32" 0. C, (N)ASPHALT SHINGLES 2' x6' ROOF RAFTERS 2 CLASS 'Afl OR "B"OVER 15 # FELT 16" OC OVER LAUNDRY AND WATER HEATER 1/2ffCCK SHEATH IN -2-2 x 4 TOP PLATE 2-2 x 4 TOP PLATE-2 x 4 STUDS @ 16' OC FIRE BLOCK AS REQ'D FIRE BLOCK AS REQ /D ----------- 2 x 4 STUDS @ 16' 0 60 R-13 INSULATION AT NEW h 21 81 EXTERIOR WALLS TYP,-`^- 2 x 4 SOLE PLT, w/ 2 x 4 SOLE PLT. w/ 16d @ 160 OC 1601 @ 16" OC SOLID BLOCKING— impson A-35 @ 8" o.c. BETWEEN JOISTS 2 x 8 MLJDSILL-----, FIRST FLOOR JOIST F , 6" Min 51" I Anchor Bolt 8ff Orf 18" Min 44 No Scale DOOR THRESHOLD MUST NOT BE OVER 2 1/2ff ABOVE OUTSIDE LANDING 18" Min 244 Rebars BOTTOM OF SILL MUST E AT LEAST 4ff ALL RISERS MUST BE EQUAL WITHIN 3/8" ABOVE CONCRETE TOLERANCE UNDER OUTSIDE FINISH MIN RISER= 4' (A) MAX RISER= 8' (A) ALSO TREADS MUST BE B EQUAL WITHIN 3/8" 3' MIN B TOLERANCE IN TREAD WIDTH= 9' C B) O < T' SECTION DETAIL D SCALE Q�pf-Efto HafthalTl Abdelhafee CD M T No.Q �3 ExP.2:L0— mr CIVIL -OFC 0 L (E)FOUNDATION E) 3 1/2"CONC, SLAB W/6x6 OVER 6 MILL VAPOR BARRIER (E) HOUSE PROPOSED ADDITION (E) GARAGE f ri 0"� SECTION DE7I r-A 11 L C MST 3 PROPOSED 14 SCALE ADDITION 1/4'=1' LEGEND ALL BRACED WALL PANELS SHALL EXTEND TO THE ROOF, SHEARING AND SHALL BE ATTACHED TO EXISTING WALL AND FT'G PARALEL ROOF. RAFTERS OR BLOCKING ABOVE WITH FRAMING NEW WALL AND FT'G CLIPS (18 GAUGE MINIMUM) SPACED 24"O.C. WITH FOUR 8o NAILS PER LEG. 1EXISTING WALL TO REMAIN (TOTAL EIGHT 8o NAILS PER CLIP) .... .... WOOD STRUCTURAL PANELS TO BE 1/2" (12.7 EXISTING WALL TO BE REMOVED MM) NOMINAL STRUCTURAL I WOOD NEW WALL STRUCTURAL PANEL MIN 4'(1.2MM) WIDE AT EA.END OR AS NEAR ENDS AS POSSIBLE VV/8D NOTES: NAILS AT 6"(1.52 MM) OR CENTER (EDGES) NOTE: BEARING WALLS STUDS CANNOT BE NOTCHED MORE THAN 25% OF AND 12"(305 MM) ON CENTER (INTERMEDIATE THEIR WIDTH, BORED HOLES CANNOT HAVE A DIAMETER GREATER FRAMING MEMBERS) OR 6" (152 MM) WHEN THAN 40% OF THE STUD WIDTH INTERMEDIATE FRAMING IS 24"(610 MM) O.C. NOTE: ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1?16" OVER SIZED AT SHEAR WALL AREAS NOTE: ALL DIAGRAM AND SHEAF DR4rSI&tN(N6BALL UTILIZED COMMON ALL DIMENTIONS TO THE FIELD VERIFIED PRIOR TO CONSTRUCTION SW22 X7-4 (SIMPSON STRONG WALL PORTAL) —7— 2 PER EACH SHERWALL NEW ONE POUR 5" CONC, SLAB 6X6; 10X10 W W M, 3' SAND BEDiiS MILL VAPOR BARRIER (E) HOUSE I PROPOSED ADD ITION/ #4x12 @ 24" o r1t E) WALL TO E4 ' 0 BE REMOVED (E) RAISE) FOUNDATION MST N I onga :M11 Mae 18"X.11 24" 9 r ALL T E) W ClL HOLE r, 0"1\ BE REMOVED 1 rl 3r =41 G2 1 L=8# 5'*� -F-T- r-j� x6' FLY R 41 Ell, ST @1E'110. 3 44, CU F) RAISE 10 14"X 18" UNDER FOUNDATION 2 LODR VENT L=4 L=41 r 3' -(R— 1 8, -2' /,I, HD2A EN- UIt HDPA HD2A (E ( 15� / 9 C� RAISEDk L, . I FOUNDATION 18"X 240 x CRAWL HOLE cu 7178�q 4/X6' Y40 X6' 18 r) (E)WALL TO j P GIRDER /;GIRDER BE REMOVED 9 /18' X 18' Q?2 r 1 ONC PAD , D 1" 3 El -HD2A 2 10 x 18" X 24" W A CRAWL HOLE 7­7 e- 18 11 , 10 -/ 4"X6 4' X6� G I RDER —,GIRDER f'7*'13 S RAISE 9 -61 18' X1 FOUNDATION HD2A-HD2A -CONC AD ,y -4 6 61 _j Fy- 7- 7- -7 -1-7- 7- 7- 7- LL- - .4 -Z in 2 x U (E)WALL TO BE REMOVED- \.O - 3 CU _j - HD2A L� I NO -v =0 1WE1 -21L �[:I­HD2A 7 ' 12- ' Li ', HD2A 'I L I,& I\ X y =41 180 X 24" L= 4' 14" X 18'-ONDER L=4' CRAWL HOLE 0 FLOOR VENT 14 B HD2A D (E) HOUSEROPOSED ADDITION 3 SCALE 1/4'=I"; -O' WALL EXT. 7/8 STUCCO TO MATCH (E) WINDOW ALLUM/GLASS GLASS TEMPERED GLASS ROOF ASPHALT SHINGLES TO MATCH (E) A PROJECT NAME AND ADDRE55 2418 W LA VERNE AV. SANTA ANA, CA 92704 Dz G) III < LU � < < 0 N > 0 44 < C\1 C\j ALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE THE PREOPERTY Of ARCHITRAVE AND WERE CREATED AND DEVELOPED FOR USE ON AND IN CONNECTION WITI-- E THIS SPECIfIC PROJECT. NONE Of SUCH IDEAS, DE51GN5 OR PLANS SHALL BE USED BY OR D15CL05ED TO ANY OTHER PERSON, CORPORATION OR FIRM FOR ANY PURPOSE WITHOUT THE WRITTEN PERMISSION Of ARCHITRAVE. IF fRANCI5CO RODRIGUEZ ADDR 5,9. 2418 W LA VERNE AV. SANTA ANA CA 92704 PROJECT (N) ADDITION IN FIRST FLOOR owner - - - - - - - - - - - - - - - - - - - date �evlsiLDIZ Issue FRAMING PLAN & FOUNDATION PLAN SCALE: 1/4" = 1' j DATE: MAY- 18-05 )Y f 175 LAV f ram foun Sect MAY 18 I e7 Gj (E)ASPHALT SHINGLES SLOPE 4 (E) BLOCK I (E)FASCIA R (E )T IM RAFTER (E) 7/8" STUCCO { E) INSULATION (E)RIDGE (E)RAFTERS C E) K I NG POST C E) CLG JST - (E) I NSULAT I ON -(E)TOP PLATE (E)STUDS @ 16" OC -- ' - -(E) F IRE BLOCK -. --- AS REQ' D (E)SILL PLT. w / 16d @ 16' OC - _ ,___` (E)INSULATION C E) G I RDER f (E) CONC, PAIL ASPHALT SHINGLES (N) 18" D I A, DORMER CLASS 'A" OR " B" OVER 15 # FELT (N) SLIMING WINDOW ULL 2,'x3'-0" i� (N) 7/8" STUCCO TO MATCH EXISTING 3 i 4 4" x 10" RIDGE 2" X 8" BEARING PLATE / 5 ASPHALT SHINGLES CLASS 'A" OR " B" OVER 15 # FELT �%�•...`' 2" X 6" RAFTERS-` 3-16d PER RAFTER 2 16" ❑, C. 2-2" x4" TOP PLATE (E) CLG JST 1 (E) I NSULAT I ON - 2" ) CLG JST @ 16" 0C 2-2" x4" TOP PLATE- " r 2" X 6" RAFTERS @ 16" ❑, C, 2" x6" BLOCKING W/A35 @ EACH BLOCK (E) TOP PLATE-' 4 X 6 HEADER- 7/8" (E)STUDS @16" OC 2" x4" STUDS @16" OC STUCCO (E)FIRE BLOCK FIRE BLOCK AS REQ' D AS REQ' D R-13 (E)SILL PLT, P" x4" SILL PLT, INSULATION w/ 16d @ 16" OC w/ 16d @ 16" ❑C AT NEW EXT. WALLS TYP, (E)INSULATION R-19 INSULATION 8 r1 9 GR DE C E) FLR, JST, (E) GIRDER C N> 4" x6"GIRDER w/PC44 (N) 1 " x18" CONC, PAD (N) 2" x6" FLR, JST. @160, C, over 5/8"T&G PLYWOOD NAILED (E) CONC, PAD (N) 4" x4" PRESSURE TREATED POST w/ 10d@6" EDGES 10" f i e l ds SECTION DETAIL SCALE 1/4' =1' -0' (N) 18" X 24"� CRAWL HOLE (N) 14" X 18" UND R FLOOR VE T PROPOSED ADDITION (E) GARAGE ASPHALT SHINGLES CLASS "A" OR " B" EAST ELEVATION SCALE C-1 MW L ASPHALT SHINGLES CLASS " A" OR " B" OVER 15 # FELT 1" X10`STARTER 1 2" x6" BLOCKING W/A35 @ EACH BLOCK 2" X 8" FASC I A TRIM RAFTER TAILS TO 2" x6" 7/8- STUCCO R-13 INSULATION AT NEW EXT. WALLS TYP, 10 1 N 7 I 8 1 1 10 I 11 4 4" x 10" RIDGE 1 4 4" x 10" R I DGE 1 2"x6"PURLING SAME 1 4x4 KING POST with 1 SIZE AS RAFTER SIMPSON BCS CAP POST 1 1 1 3-16d @ 16 01 C, 2" X 6" RAFTERS 4x4 KING PO T with 2" xkCLG JST @ 16" O, C, ASPHALT SHINGLES 2" x6" CL JST SIMPSON"BCS CAP POST @ 16" OC CLASS " A" OR " B" @ 160 OC 2" X 6 RAFTERS ASPHALT SHINGLES _—SLOPE4 � OVER 15 # FELT SL 2 APE C, CLASS 'A" OR " B" PE �L 1" X10" STARTER x` OVER 15 # FELT 1" X10" STARTER 2" x6" BLOCKING W/A35 2" x6" BLOCKING W/A35 BRACE @ 4' 0, C, @ EACH BLOCK @ EACH BLOCK 4 X 40 FOR LENGHT OVE 2" X 8" FASCIA 2" X 8" FASC I A R-30 INSULATION R- 0 INSULATION 3 TRIM RAFTER" 2-2" x4" TOP PLATE TRIM RAFTER 2-2" x4TOP PLATE TAILS TO E!! x6!! " !, ,! OC 2 x4STUDS @16 °' TO 2" x6" 2" x4" STUDS @ 16" OC BLOCK 7/8lTAILS -STUCC FIRE BLOCK STUCC❑ F I RE AS REQ' D R-13 AS REQ` D R-13 2" x4" SILL PLT, INSULATION 2!! x4" SILL PLT, INSULATION %- w/ 16d @ 16° ❑C A, T NEW EXT w/ 16d @ 16" OC AT NEW EXT, R-19 INSULATION -19 INSULATIO ALLS TYP, --WALLS TYP, 10 10 10 3; (N)4" x6" G I RDER w/PC44 c-" (N) 4" x4" PRESSURE TREATED POST (N) 18" x 18'CONC, PAD SECT10"'N DETAIL SCALE 1/4'=1'-0' RARE C N) 4" x6" GI DE w/PC44 < N7 ].8" x 8" CONC, PAD (N) 2" x6"FLR, JST, @160, C, over (N) 2" x6"FLR, JST, @160, C, over 5/8"T&G PLYWOOD NAILED (N)4"x4"PRESSURE TREATED POST 5/8"T&G PLYWOOD NAILED w/ 10d@6" EDGES 10"fields w/ 10d@6" EDGES 10"fields ASPHALT SHINGLES CLASS `A" OR " B" OVER 15 # FELT (N) 7/8" STUCCO j TO MATCH (E) MAX, B" RISE MIN, 9" RUN 1 /2" CDX PLYWD ROOF SHT' G w/APPLIED RADIENT BARRIER P, I, S2/d w/8d@6, 12, TYP (N) SLIDIN INDOW ' -0" x3' - " (N) SLIDING WINDOW 4` -0" x4' -0" (N) SLIDING WINDOW O 3' -0" x3' -0" (N) 18" X 24" (N) 7/8" STUCCO -T CRAWL HOLE TO MATCH (E) MAX, 8"RISE MIN, 9"RUN SOUTH ELEVATION SCALE ASPHALT SHINGLES CLASS 'A" OR " B" 1 /2" CDX PLYWD ROOF SHT' G OVER 15 # FELT w/APPLIED RADIENT BARRIER (N) 18" DIA, DORMER P. I, S2/d w/8d@6, 12, TYP 12 <ar tN) SLIDING WINDOW C 5' -0" x3' -0" E) SLIDING WINDO (N) SLIDING WINDOW 5' -0' x4' -0' Ll J, FEE (N) 8" X 24" (N) 7/8" STUCCO MAX, 8" RISE CR WL HOLE TO MATCH (E) M IN, 9" RUN (E) HOUSE PROPOSED ADDITION XA (ZT I=1 NATION (N) 14" FLOORUVENT _. SCALE ALL (N) MATERIALS TO MATCH EXISTING CONSTRUCTION ALL DIMENTIONS TO THE FIELD VERIFIED PRIOR TO CONSTRUCTION A 0 C tJ PROJECT NAME AND ADDRESS 1� /kv 2418 W LA VERNE AV. SANTA ANA, CA 92704 ll/ 11,11 fill ALL IDEAS, DESIGNS AND PLANS INDICATED OR REPRESENTED BY TH15 DRAWING ARE THE PREOPERTY OF ARCHITRAVE AND WERE CREATED AND DEVELOPED FOR USE ON AND IN CONNECTION WITI~ E TH15 SPECIFIC PROJECT. NONE OF SUCH IDEAS, DESIGNS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY OTHER PERSON, CORPORATION OR FILM FOR ANY PURPOSE WITHOUT THE WRITTEN PERMI551ON OF ARCHITRAVE. F HER. FRANC15CO RODRIGUEZ 24) 8 W LA VERNE AV. SANTA ANA CA 02704 ONE STORY ADDITION Owner — — — — — — — — — — — — — — — — — — — date Revision su SECTION DETAILS ELEVATIONS SCALE: 114" = 1' DATE: MAY-18-05 SHEET BY EL LAV Elevations MAY 18 0 REVIS❑NSBY The following items represent the MANDATORY REQUIREMENTS for ALL LOW RISE RESIDENTIAL buildings and shall appear as notes on the plans: A) Before the building may be occupied, installation certificates for manufactured devices regulated by the Appliance Standards or Part 6 shall be posted adjacent to the building permit(s). Certificate shall: 1, Identify features required to verify compliance with the Appliance Standards and Part 6; 2. Include the statement indicating that the installed devices conform to the Appliance Standards and Part 6 and the requirements for such devices given in the plans and specifications approved by the local enforcement agency; 3. State the number of the building permit under which the construction or installation was performed. Sec, 10-103(a)(3)(A) B) The builder shall provide the building owner, manager, and the original occupants the appropriate Certificote(s) of Compliance and a list of the features, materials, components, and mechanical devices installed in the building, and instructions on how to use them efficiently. S) Lamps used in luminaries for general lighting in kitchens and bathrooms shall have efficacy of not less than 40 lumens per watt (Fluorescent type lighting will meet this requirement). Sec. 150(k) T) In Climate Zones 14 and 16 a vapor barrier shall be installed on the conditioned space side of all insulation in all exterior walls, invented attics, and unvented crawl spaces to protect insulation from condensation. Sec. 150(g) U) Any new low-rise residential building shall meet the following minimum requirements: 1. Ceiling Insulation. The opaque portions of ceilings separating conditioned spaces from unconditioned spaces or ambient air shall meet the requirements of either 1 or 2 below: a. Ceilings shall be insulated between framing members 9 9 with insulation resulting in an installed thermal resistance of R-19 or greater for the insulation Sec. 10-103(b)(1) C) After installing wall, ceiling, or floor insulation, the installer shall post in a conspicuous location in the building a certificated signed by the installer stating that the installation is consistent with the plans and requirement of section 10-103(a) (2) (A) and conforms with the requirements of part 6. The certificate shall also state the manufacturer's name and material identification and the installed R-value. Sec, 10-103(a)(4) D) Manufactured fenestration product shalt be certified for overall U-values SHGC as rated by the National Fenestration Rating Council's NFRC 200: 1. Have a clearly visible temporaty label, not to be removed before inspection by the enforcement agency, listing the certified value, solar heat gain coefficient (SHGC) of the product and he method used to derive those values. Also the label should indicate compliance with air infiltration requirement of Section 116(a) 1 2. Have a permanent label meeting the requiemnt of section 10-111(A)(2) organization, and rating procedures. See. 116 a () E) Field fabricated skylight and windows, and exterior doors, shall be weather -stripped. EXCEPTION: Unframed glass doors and fire doors. Sec. 116(b) F) Joints and other openings in the building envelope that are potential sources of air leakage shall be caulked, gosketed, weatherstripped, or otherwise sealed to limit infiltration and exfiltratlon. Sec. 117 G) All insulating material shall be installed in compliance with the flomespread rating smoke density requirements of Sections 707 of the UBC. Sec. 118(c) H) Heat pumps with supplementary electric resistance heaters shall have controls: 1, That prevent supplementary heater operation when the heating loan con be met by the heat pump alone; and 2. In which the cut -on temperature for compression heating is higher than the cut -on temerature for supplementary heating, and the cut-off temperature for supplementary heating. Sec. 112(b) 1) Masonry or factory -built fireplaces shall have the following: 1. Closeable metal or glass doors covering the entire opening of the firebox. 2. A combustion air intake to draw air from the outside of the building directly into the firebox, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight fitting damper or combustion air control device. NOTE: Not required if fireplace is installed over a concrete slab and will not be located on an exterio r wall. 3, A flue damper with a readily accessible control, EXCEPTION: When a gas log, log lighter, or decorative gas appliance is installed in a fireplace, the flue damper shall be blocked open if required by the manufacturer's installation instructions or the State Mechanical Code, 4. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. See. 150(e) J) All heating and/or cooling systems other than wood stoves shall have an automatic thermostat with a clock mechanism or other setback mechanism that shuts the system off during periods of non-use and that allows the building occupant to automatically set back the thermostat set points for at least 2 periods within 24 hours. Sec. 150(j) K) The air handling duct system shall be constructed, installed, sealed and insulated as provided in Chapter 6 of the Uniform Mechanical Code. (Must be insulated to a minimum installed level of R-4.2 or be in conditioned space). Sec. 150(m) L) All fan systems exhausting air from the building to the outside shall be provided with backdraft or automatic dampers to prevent air leakage. Sec. 150(m)7 M) Storage gas water heaters with an energy factor<0.58 shall be externally wrapped with insulation having installed thermal resistance of R-12 or greater. Sec. 150(j)1 A N) Unfired hot water tanks, such as storage flanks and backup storage tanks for solar water heating systems, shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater or have internal insulation of at least R-16 and a label on the exterior of the tank showing the insulation R-value. Sec. 150(1)1 B 0) Duct system opening shall be sealed with mostic, tape, aerosol sealant, or other duct closure system that meets the applicable requirement of UL 181A, or UL181B including collors, connections and splices. if mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Sec, 150(m) P) Building cavities shall not used for conveying conditioned air. Sec. 150(m) Q) Joints and seams of duct system and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drowbands. Sec. 150(m) R) Piping, buried or unburned, for recirculating sections of domestic hot water system. piping from the heating source to the storage tank for an indirect -fired domestic water heating system, cooling system piping below 55 F, and the first five feet of hot and cold water pipes from the storage tank for non-recircuicting systems shall be thermally insulated in accordance with table No. 1- T Sec. 150(j)2 ALTERNATIVE to Section 150(a)l.: Insulation which is not penetrated by framing members may meet an R- value equivalent to installing R-19 insulation between framing members and accounting for the effects of framing members. b. Floors shall be insulated between framing members with insulation having on installed thermal resistance of R-19 or greater, alone. 2. Loose Fill Insulation. When loose fill insulation is installed, the minimum 'installed weight per square foot shall conform with the insulation manufacturer s installed design weight per square foot at the manufacturer's labeled R-value. 3, Wall Insulation. The opaque portions of frame walls separating conditioned spaces from unconditioned spaces or ambient air shall meet the requirements of either a or b below: a. Framed walls shall be insulated between framing members with 'insulation having an installed thermal resistance of R-13 or greater. Framed foundation walls of heated basements or heated crawl spaces shall be insulated above the adjacent outside ground line with insulation having an installed thermal resistance of at least R-13. ALTERNATIVE to Section 150(c)l.: Insulation which is not penetrated by framing members may meet an R-- value equivalent to installing R-13 insulation between framing members and accounting for the thermal effects of framing members. b. The weighted average U-value of walls shall not exceed the U-volue that would result from installing R-13 insulation between framing members and accounting for the effects of framing members. 4. Raised Floor Insulation, Raised floors separating conditioned spaces from unconditioned spaces or ambient air shall meet the requirements of either a. or b. below: a. Floors shall be insulated between framing members with insulation having an installed thermal resistance of R-13 or greater. b. The weighted average U-value of floor assemblies shall not exceed the U-value that would result from installing R-13 insulation between framing members and accounting for the effects of framing members. Sec. 150(a)-(d) SUPERIOR WINDOW & DOOR THERMAL AND OPTICAL RATINGS WITH AND WITHOUT GRIDS CLR/CLR CLR/GRAY I CLR/BRZ CLR/LOW-EI U-VALUE SERIES SHGC VT SHGC VT SHGC VT SHGC VT CLR LO% El' :.:..::.:.:..::..:.:.::.-::.;:: W ;;:•VINYL OR QOD;•:::::•:a�: .52 .53 40 .35 .43 .39 .34 .47 .47 .34 =5600XO---- W10 .57 .59 .44 .40 •47 .44 .37 .53 .47 .33 WGRID .52 .53 .39 .35 .43 .39 .33 .47 .47 .34 5700 SH W/o .57 .59 .43 .39 .47 .44 .37 .53 .47 .34 WGRID .55 .56 .41 .37 .45 Al .29 .49 .49 .35 8600xo W/o .60 .58 .46 .38 .49 .43 .32 .50 .49 .35 WGRID .55 .56 .42 .37 .45 .42 .29 .49 .49 .34 8700 sH w/o .61 .63 .46 .42 .50 .46 .32 .55 .49 .34 WGRID .61 .63 .46 .42 .50 .47 .32 .55 .48 .32 1 8602 PW w/o .67 .70 1 .50 .47 .55 .52 .35 .62 .48 .32 WGRID .50 .51 .39 .34 .42 .38 .33 .45 .50 1 .35 8900DH w/o .56 .57 .42 .38 .46 .42 .36 .51 .49 .36 WGRID .45 .46 .35 1 .31 .37 .34 1 ,24 .40 .42 .32 7100CR W/o .50 .51 .38 .34 .41 37 .26 .44 .44 .33 1 WGRID .45 .46 .35 .31 .37 .34 .24 .40 .43 .32 7300A w/o .50 .51 .38 .34 .41 .37 .26 .44 .44 .33 WGRID .65 .64 .50 .42 .54 .47 .36 .56 .49 .38 3ooxx w/o 1 .71 1 .71 1 .55 .47 .59 .52 1 .41 .63 .49 .38 a WGRID .56 .58 .43 1 .39 1 .47 .43 1 .29 .51 .49 .34 9800 xa w/o 1 62 .65 .47 .43 .51 .48 .32 1 .57 1 .49 1 .34 :•:: i::Jir:: r:i:; }:::::•: }ai?:iiiiic:ii•:^:::•: it:5i}ii?::?ir'r: t?r?i:................ ..................................................... ALUMINUM _. .. :::::::::.::::::::::;;:.::,:::;. ;:::::;::.:::?;:;<; :: ........... WGRID .63-,, 61 .49 .41 .53 .45 .35 .53 .75,, .60 460o xo W/o .68 ' 68 .53 .45 .57 .50 .38 .59 .60 WGRID 62 .60 .46 .40 .52 .44 .36 .53 .75 .60 4700 SH W/o .67 .67 .52 A4 .56 .49 .39 .59 .75 .60 WGRID .65 .68 .50 .45 .54 .50 ,36 .60 .58 .40 4602 PW w/o .71 .75 .54 .50 .59 .55 .39 .66 .58 .40 WGRID .53 .50 A2 .33 .45 37 30 43 .73 .60 4100 CR W/o .57 .55 .45 .36 .48 .41 .32 .48 .73 .60 WGRID .53 .50 .42 .33 .45 .37 .30 A3 .73 .60 4300A w/o .57 .55 .45 36 .48 Al .32 .48 .73 .60 WGRID 65 ,64 .50 .42 .54 .47 1 .37 1 .56 .75 .59 shoo xo W/o .7l .71 .55 .47 .59 .52 .41 .62 .75 .59 SHGC - Solar Heat Gain Coefficient, VT - Visible Transmittance, LOW-E I - High Performance Low E Glass SINGLE HOUSE ADDITION 7114105 Project Title Date 2418 LAVERNE AVE. SANTA ANA Project Address Building Permit # PERFECT DESIGN & ENGINEERING, INC. (626) 289-8808 Plan Check / Date Telephone Documentation Author Tele P Computer Performance 8 Field Check /Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only ae�,m - rnrrwe GENERAL INFORMATION Total Conditioned Floor Area: 1, fi ft2 Average Ceiling Height: 8,o ft Total Conditioned Slab Area: 0 ft2 Building Type: (check one or more) Q Single Family Detached Addition ❑ Single Family Attached ❑ Existing Building 1-1 Multi -Family ® Existing Plus Addition Front Orientation:(North) 0 deg Floor Construction Type: ❑ Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ®Raised Floor BUILDING SHELL INSULATION Const. Component Frame Assembly Location/Comments Type Type U-Value (attic, garage, typical, etc.) R-0 Roof R.0.24.16 Wood 0.299 Exterior Roof R-0 Wall (W.0.2x4.16) Wood 0.386 Exterior Wall R-0 Floor (F.0.24.16) Wood 0.101 Exterior Floor 1 Over Crawlspace (w/R-6 Credit) R-30 Roof(R.30.2x12.16) Wood 0.035 Exterior Roof R-13 Wall (W.13.2x4.16) Wood 0.088 Exterior Wall R-19 Floor (F.19.2x8.16) . Wood 0.038 Exterior Floor / Over Crawlspace (w/R-6 Credit)_ FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U-Factor SHGC Shading Yes / No Yes l No Right (West) 12,0 1.28 0.80 Bug Screen ❑ Rl ❑ Front (North) 32.0 1.28 0.80 Bun _Sere en ❑ ® ❑ X❑ Right (West) 41.0 0.75 0.68 Bug Screen ❑ ® ❑ [i] Left (East) 9.0 0,75 0.68 BunScreen❑ X❑ ❑ Rear (South) 62.2 0.75 0.68 Bug Screen ❑ ® ❑ X❑ ❑❑ ❑❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑ El El El El El ❑❑ El ❑ ❑ ❑ ❑ Run Initiation Time: 7 4 5 2: 2:28 Run ode: 1121367748 lEner2yPro 31 __By__En_ergySoft ---__-- User Number: 1919 Job Number. M052023 _ _-__-- _-_ Page:_3-af 20 f Certificate of Compliance: Residential Part 2 of 2 CF-1 R SINGLE HOUSE ADDITION 7114105 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heatin Equipment Minimum Type and Duct or g Pi in Thermostat Location / furnace heat Type Efficienc p { t Location P Y Y g Comments pump, etc.} (AFUE/HSPF ((ducts attic etc. R-Value Type Crsvi all FumaC+a 64% AFUE Oudess No Fan nta Setback WHOLEHOUSE Cooling Equipment Minimum Type (air conditioner, Efficiency heat pump, evap. coaling) (SEER) Duct Location (attic, etc.) Duct R-Value Thermostat Location I Type Comments No Coolinq 10.0 SEER Ductless n/a 'Setback WHOI F HQ1ISE WATER HEATING SYSTEMS Water Heater Water Heater System Name Type Distribution Type Rated 1 # in input Syst. Btu/hr Tank Cap. (gal) Energy Facts 1 External or Recovery Standbyy Tank Insui. Efficiency Loss (0o) R-Value 22V 75-7 (75 9MaA Gas Standard 170,000 0.53 n1a 12 A e._._7.5_ water heaters, list energy factor. 1 For small as storage rated Inputs of Tess than ore vat to 75 000 Btulhr electric resistance and heat pump a gy o 9 9 p 4 ). For large gas storage water heaters (rated Input of greater than 75,000 Btuthr), list Rated Input, Recovery Efficiency and Standby Loss. For Instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or owner (/ per Business & rofesslons Code) Documentation Author Name: �.aU! S Cord-2Gvt Name: RAYMOND M. ZH . Title/Firm: ARCHITRAVE Title/Firm: PERFECT NG INC. Address: 16821 HOSKINS ST. #A Address: 2416 W B HUNTINGTON BEACH CA 92649 Aiham Telephone: 213 804-1198 Telephone: 626 =am Cement : Title/Firm: _ Address: Telephone: t"[ ID p f b t-:x ir (date) (signature) i§ (date) `` 0, F IEnergyPro 3.1 By EnergySoft User Number: 1919 Job Number: M052023 Page:4 of 20 1 2) MFAR Mandatory Measures Checklist: Residential (Page 1 of 2) MFAR Mandate Measures Checklist: Residential compliance 2ch used. itemsmarked win Compliance: Residential Addendum CF-1 R sub ect to the Standards must contain these measures regardless of the compliance approach used. items marked with an NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the Compliance. p PP ro �ertlflcate ®fNOTE: Lowrise residentlat jof asterisk (`) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. when this checklist Is rated into incorporated into Efseads ()documents�tho feat bes noted sdhagl be considered by allrparties as m nmumlisted on o o pia ent performance $pacification s for the mandatcklist Is orymeasuras SINGLE HOUSE ADDITION 7114/05 _ Date the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures permit whether they are shown elsewhere In that documents or on this checklist only. Project Title h i where in the documents or on this checklist only, Special Features and Modeling Assumptions The Iocai enforcement agency should pay special attention to that items specified in this checklist, Those items require special The local written justification and documentation, and special verification to be used with thebp; aomo� edeeaP nrthat otherwise complies enforcement agency determines the adequacy of the justification, and may reject a u g g based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "RHEEM 22VR75-70N (75 GAL.)" Energy Factor = 0.530. An EF below 0.68 requires an R-12 External Blanket. HERS Required Verification fi d HERS t r under the supervision of a CEC approved HERS rhese features must be confirmed and/or tested by a certi a rate provider, The HERS rater must document the field verification and diagnostic testing of these measures on a form CF-6R. Plan Field I RunInntiatiggTi 14 0512:02.28 Run _ d : 1121367 4 EnergyPra 3.1 By EnergySaft User Number. 1919 Job Number: M052023 Page:5 of 20 whether they are s own a se DESCRIPTION instructions: Check or Initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures ® '§ 15o(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R-Value. § 150(c): Minimum R-13 wail insulation Inwood framed wails or equivalent U-value in metal frame waits (does ❑ * not apply to exterior mass walls). o ' §150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. ❑§ 150(I): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 permlinch. ® 6118: Insulation specified or installed meets Insulation quality standards, indicate We and form. ® §116-17: Fenestration Products, Exterior Doors and InfiltrationExhitration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g}. Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ § 15o(f): special Infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air Intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑ §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § I50(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ® § 15o(I): setback thermostat on all applicable heating and/or cooling systems. ® 15oa): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an Installed thermal resistance of R-12 or greater. 2. First 5 fleet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external Insulation or R-16 combined internal/external insulation. 4, All buried or exposed piping insulated In recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. Insulated. 6, Piping insulating between heating source and indirect hot water tank. EnergyPro 3,1 BY EnergySoft User Number. 1g19 Job Number. M052023 Page:6 of 20 VERPTION Instructions: Check or initial appticabteboxes or enter NIA If not applicable. DESIGNER ENFORCEMENT nditioning, Water Heating and Plumbing System Measures: (continued) m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1g98 CMC sections 601, nimum installed level of R-4.2 or enclosed entirely in 603,604 and Standard 6-3: ducts insulated to a mi conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct-ciasura system that meets the applicable requirements of UL181, UL181A, or 1.10818, if mastic or tape is used to seal openings greater than 114 Inch, the combination of mastic and either mesh or tape shall be used. Building cavities shalt not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands, 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or nexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed In cavities and support platforms shall not be compressed to cause reductions In the cross -sectional area of the ducts, 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eltherautomane or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, Including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam Insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material, 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on -off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between fitter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch, §115: Gas fired central furnaces, pool heaters, spa heaters or household crooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btuthr) ❑ §118 (f): Coot Roof material meet specified criteria Lighting Measures ❑ § 15o(k)1: Luminaires for general lighting in kitchens shall have tamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. L+~ t §150(k)2: Rooms with a shower or bathtub must have either at least one tuminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number 1919 lob Number: M052023 Page:7 of 20 DATE ,OJECT NAME SINGLE HOUSE ADDITION 7/14/05 STEM NAME FLOOR AREA WHOLE HOUSE 1 306 Number of Total O Output Output per System c Total Output (Btuh) 0 Total Output (Tons) 0.0 Total output (Stuh/sgft) 0.0 Total output (sgft/Ton) 0,0 CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm(Ton) Outside Air (%) Outside Air (cfmisgft) Note: values above given at ARI conditions 33,0 of Outside ""'�'""� 0 cfm 70.0 of 97.2169.5 of Out--- i❑ 0 cfm 78.0I62.1 of 3,1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD CFM f Sensible! Latent CFM Sensible 38 34 122I 41 080 MONTEREY 60GV 0 0 32,000 Total Adjusted System Output o 0 (Adjusted for Peak Design Conditions) �-�32,000 TIME OF SYSTEM PEAK Aug 2m Jan 12 am 105.0 of Heating Coil f, Return Air Ducts `i 78.0 / 62.10F r 55,0153,5 of 1919 Cooling Coil h Return Air Ducts ` Supply Air Ducts 105.0 of RO®MS 70.0 of 1 Supply Air Ducts �55y.0 l 53.5 of ' 40,8°!e R.H. Rt)OMS i 78.0/62.1oF of 20 Date /i 2005 Scale Drawn _ Sh[eet (�j p A �} C!-- t (\y!1/ F-1 R & MANDATORY REQUIREMENTS Of Sheets