Loading...
HomeMy WebLinkAbout2314 W San Lorenzo Ave - Plan (2)STRUCTURE TOTAL LIVABLE: FIRST FLOOR 1,012 S.F. SECOND FLOOR 899 S.F. GARAGE: 453 S.F. LIVIABLE + GARAGE:2,364 S.F. TOTAL LIVIABLE:1,911 S.F. TOTAL NON-LIVABLE: 453 S.F. TOTAL BUILDING:2,364 S.F. LOT COVERAGE TOTAL BUILDING COVERAGE: EXISTING:2,995 S.F. PROPOSED: - TOTAL LOT AREA:6,778 S.F. (2,364 / 6,778) x 100 = 35% LOT COVERAGE OCCUPANCY GROUP: TYPE OF CONSTRUCTION: BUILDING CODES: OWNER THOMAS & THOM NGUYEN DESCRIPTION OF WORK REMODEL RESIDENTIAL PROJECT. REMOVE INTERIOR KITCHEN WALL AND PROPOSE OPEN KITCHEN FLOOR PLAN. REMODEL OF THE KITCHEN. ENCLOSED LAUNDRY ROOM AS A SEPARATE ROOM. REMODEL MASTER BATHROOM WITH NEW SHOWER FIXTURE. DEMO UNPERMITTED PATIO COVER PER PLANNING COMMENT. TYPE V-B, NON-SPRINKLERED THE PROJECT SHALL COMPLY WITH THE FOLLOWING: 412-262-30 / TRACT: 8344 LOT: 72A. P. NUMBER: 2314 W SAN LORENZO AVE SANTA ANA, CA 92704 STATISTICS: R-3/U SINGLE FAMILY RESIDENTIALZONE: & SANTA ANA MUNICIPAL CODE (SAMC). R-3/U, EXISTING 2-STORY SINGLE FAMILY RESIDENTIAL WITH ATTACHED GARAGE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BLDG. STANDARDS 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRIC CODE 2022 CALIFORNIA ENERGY CODE PHONE # (714) 657-4277 PROJECT TEAM DRAFTER: O1DESIGN GROUP ANAHEIM, CA 92801 (714) 261-9576 o1designgroup@gmail.com GENERAL CONTRACTOR:STRUCTURAL: THANH HUYNH LIC. C88427 (949) 466-7857 tonyhuynh2404@gmail.com.com PLAID CONSTRUCTION CONTRACT, LIC. 110957 16461 MAGNOLIA ST WESTMINSTER, CA, 92683 (714) 875-6388 shawncao@live.com VICINITY MAP W SAN LORENZO AVE PROJECT INFORMATIONSHEET INDEXGENERAL NOTES ABBREVIATIONS BLDG. DEPT. NOTES A.B. ABV. A.C. A/C ADDL. A.D. ADJ. ADJA. A.F.F. AGGR. AHU ALUM. ALT. ANOD. ARCH. ASPH. AVG. ANCHOR BOLT ABOVE ASPHALT CONCRETE AIR CONDITIONING ADDITIONAL AREA DRAIN ADJUSTABLE ADJACENT ABOVE FINISHED FLOOR AGGREGATE AIR HANDLER UNIT ALUMINUM ALTERNATE ANODIZED A RCHITECTURAL ASPHALT AVERAGE BD. BLDG. BLK. BLKG. BM. B.M. B.O. B.U.R. BOARD BUILDING BLOCK BLOCKING BEAM BENCH MARK BOTTOM OF BUILT UP ROOFING CER. C.I.P. C.J. C.T. CAB CEM CL CLG. CLKG. CLO. CLR. CMU CNTR. C.O. COL. CONC. CONST. CONT. CONTR. CORR. CTR. CTSK. CERAMIC CAST IN PLACE CONTROL JOINT CERAMIC TILE CABINET CEMENT CENTERLINE CEILING CAULKING CLOSET CLEAR CONCRETE MASONRY UNIT COUNTER CLEAN OUT COLUMN CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR CORRIDOR CENTER COUNTERSUNK D. DBL. DEPT. DET. D.S. DEMO DIA. / Ø DIAG. DIM. DN DR DEEP, DEPTH DOUBLE DEPARTMENT DETAIL DOWN SPOUT DEMOLITIION DIAMETER DIAGONAL DIMENSION DOWN DOOR EA. E.F. E.J. EL. ELECT. EQ. EQUIP. EST. EXIST. / (E) EXT. EACH EXHAUST FAN EXPANSION JOINT ELEVATION ELECTRIC, ELECTRICAL EQUAL EQUIPMENT ESTIMATE EXISTING EXTERIOR F.A. F.D. F.E. F.E.C. F.G. F.O. F.O.B. F.O.C. F.O.F. F.O.M. F.O.S. F.Y.S.B. FAB. FDN. FHC FIN. FIN. FLR. FL. / FLG. FLUOR. F.R.P. F.S. FTG. FURN. FURR. FIRE ALARM FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISHED GRADE FACE OF FACE OF BLOCK FACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUDS FRONT YARD SETBACK FABRICATE FOUNDATION FIRE HOSE CABINET FINISH FINISH FLOOR FLOORING FLUORESCENT FIBERGLASS REINFORCED PANEL FINISHED SLAB FOOTING FURNISH FURRING G.I. GA. GALV. GAR. GL. GLB GYP. GYP. BD. H.B. H.C. H.M. HDBD. HDW. HT HOR. HVAC HW INCL. INSUL. INT. JST. GALVANIZED IRON GAUGE GALVANIZED GARAGE GLASS GLUE LAMINATED BEAM GYPSUM GYPSUM BOARD HOSE BIBB HOLLOW CORE HOLLOW METAL HARDBOARD HARDWARE HEIGHT HORIZONTAL "HEATING, VENTILATING & AIR CONDITIONING" HOT WATER INCLUDE, INCLUSIVE INSULATION INTERIOR JOIST LAM LAV LT. LTG. LAMINATE LAVATORY LIGHT LIGHTING M.B. M.O. MAS. MAT'L MAX. MECH. MEMB. MFG. MFR. MIN. MISC. MIR. MTL MUL MACHINE BOLT MASONRY OPENING MASONRY MATERIAL MAXIMUM MECHANICAL MEMBRANE MANUFACTURING MANUFACTURER MINIMUM MISCELLANEOUS MIRROR METAL MULLION (N) N.I.C. N.T.S. NO. NOM. NEW NOT IN CONTRACT NOT TO SCALE NUMBER NOMINAL O.C. OFF. O.I. OPN'G OPP. ON CENTER OFFICE ORNAMENTAL IRON OPENING OPPOSITE P.L. P.LAM. PERF. PERP. PH. P.I.P. PLAST. PLUMB. PLYWD. PORC. PREFAB. PSF PSI PTN. PVC PROPERTY LINE PLASTIC LAMINATE PERFORATED PERPENDICULAR PHASE POURED IN PLACE PLASTER PLUMBING PLYWOOD PORCELAIN PREFABRICATED POUNDS PER SQUARE FEET POUNDS PER SQUARE INCH PARTITION POLYVINYLCLORIDE QTY. QUANTITY R. RAD. R.D. REINF. REF. REFG. REQ'D RESIL. REV. RM R.O. R.Y.S.B. RISER RADIUS ROOF DRAIN REINFORCED REFERENCE REFRIGERATOR REQUIRED RESILIENT REVISION ROOM ROUGH OPENING REAR YARD SETBACK T&G T.O. T.O.B. T.O.C. T.O.F. T.O.J. T.O.M. T.O.S. T.O.W. T.S. T.V. TEL. TH. THD. THK. THRU TRANS. TYP. TONGUE AND GROOVE TOP OF TOP OF BEAM TOP OF CURB TOP OF FOOTING TOP OF JOIST TOP OF MASONRY TOP OF STEEL TOP OF WALL TUBE STEEL TELEVISION OUTLET TELEPHONE THRESHOLD THREADED THICK THROUGH TRANSFORMER TYPICAL U.N.O. UNLESS NOTED OTHERWISE VEST. V.I.F. VCT VERT. VESTIBULE VERIFY IN FIELD VINYL COMPOSITION TILE VERTICAL W/C W.H. WCT WT. W/ W/O WD. W.I. WATER CLOSET WATER HEATER WAINSCOT WEIGHT WITH WITHOUT WOOD WROUGHT IRON YD. YARD S.B. S.C. S.D. S.S. S.Y.S.B SCHED. SECT. SHR. SHT'G. SIM SL. SLDG. SPECS SPKR. SQ. FT. / S.F. SQ. IN. STC STL STOR. STRL. SUSP. SYM SYS. SETBACK SOLID CORE SMOKE DETECTOR STAINLESS STEEL SIDE YARD SETBACK SCHEDULE SECTION SHOWER SHEATHING SIMILAR SLOPE SLIDING SPECIFICATIONS SPEAKER SQUARE FEET SQUARE INCHES SOUND TRANSMISION CLASS STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL SYSTEM SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 3 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N 05 - 0 8 - 2 6 B U I L D I N G C O R R E C T I O N SHEET DESCRIPTION IS S U E A N D RE V I S I O N S 10 - 0 9 - 2 0 2 5 I N I T I A L SU B M I T T A L 03 - 2 0 - 2 0 2 6 RE - S U B M I T T A L 05 - 0 8 - 2 0 2 6 RE - S U B M I T T A L GENERAL A0.0 TITLE SHEET X X X A0.1 NOTES AND SPECIFICATIONS X X X A0.2 NOTES AND SPECIFICATIONS X X X A0.3 NOTES AND SPECIFICATIONS X X X A0.4 CALGREEN BUILDING STANDARDS X X A0.5 CALGREEN BUILDING STANDARDS X X ARCHITECTURAL A1.0 EXISTING SITE PLAN FOR REFERENCE X X X A2.1 DEMOLITION FIRST & SECOND FLOOR PLAN X X X A3.1 PROPOSED FIRST & SECOND FLOOR PLAN X X X A3.4 PROPOSED FIRST & SECOND FLOOR UTILITY PLAN X X X A5.0 SECTIONS X X AD1.0 DETAILS X X X AD2.0 DETAILS X X X X X X STRUCTURAL S0 STRUCTURAL GENERAL NOTES X X X S1 FOUNDATION PLAN & FRAMING PLAN X X X SD1 FOUNDATION DETAILS X X X A0.0 TITLE SHEET 1. THE PLANS FOR SINGLE FAMILY DWELLINGS AND DUPLEXES ARE NOT CHECKED FOR ELECTRICAL, MECHANICAL, AND PLUMBING CODE COMPLIANCE AND THESE DISCIPLINES ARE SUBJECT TO FIELD INSPECTION AND APPROVAL BY THE INSPECTOR 1. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS & ELEVATIONS BEFORE PROCEEDING WITH THE WORK. 2. ALL DIMENSIONS ARE TO THE FACE OF STUDS, FACE OF CONCRETE OR MASONRY, FACE OF FINISH WHERE NOTED, & CENTERLINE OF COLUMNS, U.N.O.. ALL DIMENSIONS NOTED AS "CLEAR" SHALL BE TO FACE OF FINISH. 3. ALL CONSTRUCTION SHALL COMPLY WITH THE LATEST EDITION OF THE CALIFORNIA BUILDING CODE, CALIFORNIA PLUMBING CODE, NATIONAL ELECTRICAL CODE, NATIONAL FIRE CODE, AMERICANS W/ DISABILITIES ACT (ADA) ACCESSIBILITY GUIDELINES, CALIFORNIA CODE OF REGULATIONS TITLE 24 PARTS 1-5, 9 & 12 U.N.O. 4. IT SHALL BE THE RESPONSIBILITY OF ANYONE SUPPLYING LABOR OR MATERIALS OR BOTH TO BRING ANY DISCREPANCY OR CONFLICT OF THE CODE AND THE DRAWINGS TO THE ATTENTION OF THE ARCHITECT. 5. REFERENCE TO ANY DETAIL OR DRAWING IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS. 6. DISCREPANCIES IN THE DRAWINGS OR BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE ARCHITECT. 7. CONTRACTOR TO CHECK & VERIFY SIZE & LOCATION OF DUCTS, PLUMBING RUNS & MECHANICAL & ELECTRICAL EQUIPMENT BEFORE CONSTRUCTING WALLS, FLOOR, CEILINGS, CABINETS, EQUIPMENT BASES, ETC. 8. CONTRACTOR IS RESPONSIBLE FOR ALL WORK SHOWN ON THESE DRAWINGS AND SPECIFICATIONS UNLESS SPECIFICALLY NOTED OTHERWISE. 9. THE CONTRACT DRAWINGS & SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE UNLESS OTHERWISE SHOWN; THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. OBSERVATION VISITS TO THE SITE BY FIELD REPRESENTATIVES OF THE ARCHITECT AND ENGINEERS SHALL NOT INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OR THE CONSTRUCTION PROCEDURES REQUIRED FOR SAME, WHICH ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. ANY SUPPORT SERVICES PERFORMED BY THE ARCHITECT AND ENGINEERS DURING CONSTRUCTION SHALL BE DISTINGUISHED FROM CONTINUOUS AND DETAILED INSPECTION SERVICES WHICH ARE FURNISHED BY OTHERS. THESE SUPPORT SERVICES PERFORMED BY THE ARCHITECT AND ENGINEERS, WHETHER OF MATERIAL OR WORK, AND WHETHER PERFORMED PRIOR TO DURING OR AFTER COMPLETION OF CONSTRUCTION ARE PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AND IN ACHIEVING CONFORMANCE WITH CONTRACT DRAWINGS AND SPECIFICATIONS. BUT THEY DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE AND SHALL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION. 10. THE CONTRACTOR SHALL PROVIDE COORDINATION BETWEEN ALL SUBCONTRACTORS AND TRADES. 11. THE CONTRACTOR WARRANTS TO THE OWNER AND THE ARCHITECT UNLESS OTHERWISE SPECIFIED, ALL PRODUCTS SHALL BE NEW, FREE OF DEFECTS AND FIT FOR THE INTENDED USE. 12. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. CONTACT SERVING UTILITIES AND/OR LOCAL UNDERGROUND SERVICE ALERT. THE CONTRACTOR SHALL BEAR ALL EXPENSES OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH EQUIPMENT SUPPLIED BY THE OWNER. 14. CERTAIN ITEMS OF EQUIPMENT OR FURNISHINGS WILL BE FURNISHED AND INSTALLED BY THE OWNER AND ARE INDICATED AS N.I.C., OTHER ITEMS WILL BE FURNISHED BY THE OWNER FOR INSTALLATION BY THE CONTRACTOR AS WORK OF THIS PROJECT AND ARE INDICATED AS "OWNER FURNISHED CONTRACTOR INSTALLED" (OFCI). 15. CONTRACTOR SHALL NOTIFY THE ARCHITECT OR ENGINEER OF ANY DISCREPANCIES, OMISSIONS OR AMBIGUITY IN THE DRAWINGS OR SPECIFICATIONS. 16. ITEMS OF A MECHANICAL OR ELECTRICAL NATURE MAY NOT NECESSARILY APPEAR ON THE ARCHITECTURAL DRAWINGS. SEE THE APPROPRIATE CONSULTANT DRAWINGS FOR ITEMS OF THIS NATURE. 17. FOR ALL WALL MOUNTED AND SEMI-RECESSED MOUNTED EQUIPMENT, ACCESSORIES, CABINETS, HANDRAILS, MECHANICAL/ELECTRICAL EQUIPMENT, ETC, PROVIDE SOLID BLOCKING OR BACKING PLATE. 18. PROVIDE PORTABLE FIRE EXTINGUISHER UNITS IN RECESSED CABINETS AS SHOWN AND AS DIRECTED BY THE AUTHORITY HAVING JURISDICTION. LOCATION AND TYPE OF EACH UNIT WILL BE DETERMINED BY THE AUTHORITY HAVING JURISDICTION. PROVIDE IN SUCH LOCATIONS SO THAT MAXIMUM FLOOR TRAVEL DISTANCE SHALL NOT EXCEED 75' TO THE NEAREST EXTINGUISHER FROM ANY POINT IN THE BUILDING WITHOUT GOING UP OR DOWN STAIRS. 19. THE CONTRACTOR SHALL SAFEGUARD THE OWNERS PROPERTY DURING CONSTRUCTION AND SHALL REPLACE ANY DAMAGED PROPERTY OF THE OWNER TO ORIGINAL CONDITION OR BETTER. 20. CONTRACTOR SHALL NOT BREAK SETS. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, WHAT IS REQUIRED BY ANY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. 21. ALL WORK SHALL BE IN ACCORDANCE WITH CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION PER THE 2019 CALIFORNIA BUILDING CODE. 22. PROVIDE PEDESTRIAN PROTECTION BARRICADES AND/OR CANOPIES AS REQUIRED BY THE LOCAL AUTHORITIES, OR AS NECESSARY FOR PEDESTRIAN SAFETY. 23. ALL 'OR EQUAL" & "OR APPROVED ALTERNATIVE" SUBSTITUTIONS MUST BE SUBMITTED TO AND APPROVED BY THE BUILDING OFFICIAL PRIOR TO INSTALLATIONS OF THE ITEM. 24. ALL WATERPROOFING SHALL BE VERIFY BY WATERPROOFING CONSULTANT. ALL WATERPROOFING AT GRADE AND SUB-GRADE PER GEOTECHNICAL REPORT, SHALL BE VERIFY BY WATERPROOFING CONSULTANT. PUBLIC WORKS NOTES PLANNING NOTES N   DEFERRED SUBMITTALS ARE TO BE REVIEWED BY PROJECT ARCHITECT AND/OR ENGINEER OF RECORD, & CERTIFIED FOR CONFORMANCE W/ BLDG. DESIGN CRITERIA PRIOR TO SUBMITTAL FOR PLAN CHECK OR APPROVAL BY THE CITY. DEFERRED SUBMITTALS AND PERMITS BY OTHERS: S C E N T E R S T PROJECT SITE S R A I T T S T W CHANDLER AVE W SEGERSTROM AVE 1 2 2 2 2 3 DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO A0.1 GENERAL NOTES AND SPECIFICATIONS DIVISION 1: GENERAL REQUIREMENTS SECTION 1 ARCHITECT'S STATUS: THE ARCHITECT DOES NOT GUARANTEE ANY TRADE OR SUB'S PERFORMANCE, AND ND PROVISIONS OF THE CONTRACT DOCUMENTS SHALL RELIEVE THE TRADES OR SUB'S FROM ANY LIABILITY DUE TO NEGLIGENCE, INCOMPETENCE OR ERRORS OF OMISSION OR COMMISSION OF THE TRADE OR SUB. THE DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND HAS NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER. THE BUILDER/ 0WNER IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE PRIOR TO THE APPLICATION OF ALL SHEAR WALLS, ROOF AND FLOOR DIAPHRAGMS AND FINISH MATERIALS. HE SHALL PROVIDE THE NECESSARY BRACING TO PROVIDE STABILITY PRIOR TO THE APPLICATION OF THE AFOREMENTIONED MATERIALS. OBSERVATION VISITS TO THE JOB SITE BY THE ARCHITECT/ENGINEER DO NOT INCLUDE INSPECTION OF CONSTRUCTION PROCEDURES. THE BUILDER IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION METHODS AND FOR SAFETY CONDITIONS AT THE WORK SITE. THESE VISITS SHALL NOT BE CONSTRUED AS CONTINUOUS AND DETAILED INSPECTIONS. SECTION 1-B CODES: ALL CODES HAVING JURISDICTION SHALL BE OBSERVED STRICTLY IN THE CONSTRUCTION OF THE PROJECT INCLUDING ALL APPLICABLE CODES. BUILDER SHALL VERIFY ALL CODE REQUIREMENTS BEFORE THE COMMENCEMENT OF CONSTRUCTION AND BRING ANY DISCREPANCIES BETWEEN CODE REQUIREMENTS AND THE CONSTRUCTION DOCUMENTS TO THE ATTENTION OF THE ARCHITECT. A PARTIAL LIST OF APPLICABLE CODES IS LISTED ON THE COVER SHEET. SECTION 1-C ERRORS AND OMISSIONS: ERRORS AND OMISSIONS WHICH OCCUR IN CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. FIRST BY PHONE OR BY FAX AND THEN IN WRITING. WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK THE BUILDER OR SUB SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS OF WHICH THE BUILDER OR SUB FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK. SECTION 1-D JOB CONDITIONS: THE BUILDER AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB CONDITIONS AT THE JOB SHALL SUFFICIENTLY IN ADVANCE OF WORK TO BE PERFORMED TO ASSURE ORDERLY PROGRESS OF THE WORK. THE ARCHITECT OR ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCY BY PHONE, FAX AND WRITTEN MESSAGE. THE BUILDER OR SUBCONTRACTOR SHALL REPORT TO PROJECT SUPERINTENDENT ALL CONDITIONS WHICH PREVENT THE PROPER EXECUTION OF THEIR WORK. NOTE: ALL DRAWINGS ARE DRAWN TO THE SCALE AS NOTED, FOR REFERENCE ONLY. DO NOT SCALE DRAWINGS. UNLESS IT IS NOTED OTHERWISE, DETAILS ARE NOT TO ANY GIVEN SCALE. DISCREPANCIES BETWEEN DIMENSIONS AND WRITTEN NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. SECTION 1-E KNOWLEDGE TO COMPLETE CONSTRUCTION: THE SCOPE OF THIS SET OF PLANS IS SUFFICIENT TO OBTAIN A BUILDING PERMIT; HOWEVER, ALL MATERIALS AND METHODS OF CONSTRUCTION NECESSARY TO COMPLETE CONSTRUCTION ARE NOT NECESSARILY DESCRIBED. THE PLANS DELINEATE AND DESCRIBE ONLY LOCATIONS, DIMENSIONS, TYPES OF MATERIALS AND GENERAL METHODS OF ASSEMBLY OR FASTENING. THEY ARE NOT INTENDED TO SPECIFY PARTICULAR PRODUCTS OR METHODS OF ASSEMBLY OF ANY SPECIFIC MATERIAL DR PRODUCT THE IMPLEMENTATION OF ME PLAN REQUIRES A BUILDER AND /OR SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WILL, THE APPLICABLE BUILDING CODES AND METHODS OF CONSTRUCTION SPECIFIC TO THIS PRODUCT TYPE AND TYPE OF CONSTRUCTION. SECTION 1-F CLEAN UP: CONTRACTORS SHALL MAINTAIN THE PREMISES CLEAN AND FREE OF ALL TRASH, DEBRIS AND SHALL PROTECT ALL ADJACENT WORK FROM DAMAGE, SOILING, PAINT OVERSPRAY, ETC. ALL FIXTURES, EQUIPMENT, GLAZING, FLOORS, ETC. SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON COMPLETION OF THE PROJECT. GENERAL: A. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER THESE GENERAL NOTES. B. NAMED PRODUCTS: THE ARCHITECT MAKES NO GUARANTEE FOR PRODUCTS IDENTIFIED BY TRADE NAME OR MANUFACTURER. C. SCOPE: THE BUILDER AND SUBCONTRACTORS SHALL FURNISH ALL LABOR, EQUIPMENT, AND MATERIAL INDICATED ON THE PLANS AND REASONABLY INFERRED OR REQUIRED BY THE APPLICABLE CODES. D. SUBSTITUTIONS: NO SUBSTITUTIONS SHALL BE MADE WITHOUT OWNER'S WRITTEN AUTHORIZATION. ANY SUBSTITUTION SHALL BE MADE KNOWN TO OWNER/BUILDER AND ARCHITECT IN ADVANCE TO AVOID ANY DELAY IN THE PROJECT SCHEDULE. THE GENERAL CONTRACTOR AND ANY SUBCONTRACTOR SHALL NOT MAKE STRUCTURAL SUBSTITUTIONS OR CHANGES WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE STRUCTURAL ENGINEER AND WRITTEN NOTIFICATION TO THE ARCHITECT. E. CHANGES, ANY ADDITION, DELETION, OR CHANGE IN THE SCOPE OF THE WORK DESCRIBED BY THE PLANS SHALL BE BY WRITTEN CHANGE ORDER ONLY. ANY APPROVAL FROM THE BUILDING OFFICIAL FOR A CHANGE IN THE WORK SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. F. STRUCTURAL OBSERVATION, OWNERS SHALL BE RESPONSIBLE TO FULFILL THE REQUIREMENTS OF SECTION 1704 OF THE CBC TO EMPLOY HIS DESIGNATED ENGINEER TO MAKE SITE VISITS TO OBSERVE GENERAL COMPLIANCE WITH THE APPROVED STRUCTURAL PLANS AND CHANGE ORDERS. THE ENGINEER SHALL SUBMIT A STATEMENT IN WRITING TO THE BUILDING OFFICIAL STATING THE SITE VISITS HAS BEEN MADE AND THAT ANY DEFICIENCIES NOTED HAVE BEEN CORRECTED TO THE EXTENT AS DETERMINED BY THE BUILDING DEPARTMENT. G. INFILTRATION CONTROL, ALL OPENINGS IN THE BUILDING ENVELOPE MUST BE CAULKED, GASKETED OR WEATHER STRIPPED IN ACCORDANCE WITH MANDATORY STATE ENERGY REQUIREMENTS. FOUNDATIONS: INSTALL AS INCLUDED IN THE STRUCTURAL DRAWINGS AND AS AMENDED BY THE FINAL SOILS REPORT WHERE PROVIDED. REFER TO THE ARCHITECTURAL DRAWINGS WERE APPLICABLE FOR MOLDS, GROOVES, ORNAMENTS, CLIPS OR GROUNDS REQUIRED TO BE CAST IN CONCRETE AND FOR LOCATIONS OF FLOOR FINISHES AND SLAB DEPRESSIONS. DIVISION 2: SITEWORK SECTION 2 EARTHWORK: PERFORM ALL WORK IN THIS SECTION IN CONFORMANCE WITH THE FINAL SOILS COMPACTION, GEOLOGICAL REPORTS AND/OR APPROVED ENGINEERED GRADING PLAN WHERE APPLICABLE AS ACCEPTED BY THE BUILDING DEPARTMENT. SECTION 2-A GRADING: A. SEE CIVIL ENGINEERING DRAWINGS AND NOTES WHEN PROVIDED. B. SITE GRADING. THE GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL BE SLOPED AWAY FROM THE BUILDING A MINIMUM OF 6" WITHIN THE FIRST 10 FEET MEASURED PERPENDICULAR TO THE FACE OF THE WALL IF PHYSICAL OBSTRUCTIONS OR LOT LINES PROHIBIT 10 FEET OF HORIZONTAL DISTANCE, A 5% SLOPE SHALL BE PROVIDED TO AN APPROVED ALTERNATIVE METHOD OF DIVERTING WATER AWAY FROM THE FOUNDATION. SWALES USED FOR THIS PURPOSE SHALL BE SLOPED A MINIMUM OF 1% WHERE LOCATED WITHIN 10 FEET OF THE BUILDING FOUNDATION. IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2% AWAY FROM THE BUILDING. (CRC R401.3) DIVISION 3: CONCRETE GENERAL: A. REFER TO STRUCTURAL DRAWINGS BY OTHERS FOR CONCRETE SPECIFICATIONS NOTES, DETAILS AND EMBEDMENT TO BE USED ON THIS PROJECT FOR STRUCTURAL SLABS AND FOOTINGS. B. IT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE SUBCONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTIONS OF THIS WORK. C. SOILS ENGINEER SHALL INSPECT FOUNDATION PRIOR TO POURING CONCRETE AND VERIFY SOIL BEARING PRESSURE AS RECOMMENDED IN THE SOILS REPORT. D. TOP OF CONCRETE SLABS TO BE MINIMUM 6 INCH (8 INCH-HUD) ABOVE FINISH GRADE. E. CONTRACTOR SHALL HAVE COUNTY APPROVED TRUSS PLANS ON THE JOB PRIOR TO FOUNDATION INSPECTION WHEN APPLICABLE. SECTION 3-A EXT. FLAT WORK AND NONSTRUCTURAL CONCRETE. CONCRETE 2,500 PSI AT 28 DAYS, 7.5 GALLONS WATER MAXIMUM PER SACK OF CEMENT (U.N.O.) PORTLAND CEMENT ASTM C150-72 AND C595-72 TYPE I OR II. LOW ALKALI, MILL TESTED AND CERTIFIED. USE TYPE V CEMENT AND MAXIMUM WATER TO CONCRETE RATIO OF .45 FOR SOIL CONTAINING SULFATE CONCENTRATIONS OF MORE THAN 0.2 PERCENT ON ALL STRUCTURAL CONCRETE (REFER TO SOILS REPORT WHEN PROVIDED). WATER: FROM DOMESTIC SOURCES, CLEAN AND FREE FROM ALL ORGANIC OR OTHER DELETERIOUS MATERIALS. LIGHT WEIGHT AGGREGATES: ASTM C330-69 AND 0332-66. SAND AND STRUCTURAL AGGREGATES, ASTM C-3371A. ADMIXTURE. PER ASTM C260-60, C494-71 AND C618-77. WATERPROOFING: SHALL BE INSTALLED PER MFR'S SPECS. A PROPER SYSTEM SHALL INCLUDE WATERPROOF MEMBRANE, SUBSURFACE FOUNDATION DRAIN, POROUS BACKFILL (OR DRAIN SCREEN) AND PROTECTION BOARD. SECTION 3 - B REINFORCING STEEL: WORKMANSHIP: ALL WORK SHALL COMPLY WILL, THE REQUIREMENTS SET FORTH IN THE CURRENT CRC CODE. DIVISION 4: MASONRY SECTION 4-A MANUFACTURED / "STUCCO" STONE. A. MANUFACTURED STONE VENEER SHALL BE INSTALLED PER SECTION 4-B BRICK MASONRY AND PAVERS: A. MASONRY SHALL COMPLY WITH CRC CHAPTER 6. B. MASONRY VENEER SHALL COMPLY WITH CRC SECTION R702.1 AND R703. C. REINFORCING SHALL BE ACCURATELY PLACED, AND HELD IN POSITION TOP AND BOTTOM. ANCHORED MASONRY AND STONE WALL VENEER SHALL NOT EXCEED 5" IN THICKNESS, SHALL BE INSTALLED IN ACCORDANCE WITH CHAPTER 7, TABLE R703.4, AND FIGURE R703.7 AND SHALL NOT EXTEND ABOVE THE FIRST STORY UNLESS DESIGN COMPLIES WITH CRC TABLE R703.7(2) MASONRY VENEER SHALL BE ANCHORED TO THE SUPPORTING WALL IN ACCORDANCE WITH SECTION R703.7.4, INCLUDING THE REQUIRED SIZE AND SPACING OF TIES, THE REQUIRED AIR SPACE OR ALTERNATE MORTAR/ GROUT FILL, AND THE REQUIRED FLASHING AND WEEP HOLES. MASONRY VENEER, PROVIDE NOT LESS THAN 5/8 INCH OR MORE THAN 1 1/4 INCH MORTAR BETWEEN MASONRY VENEER AND "DIAMOND MESH METAL LATH" AS MANUFACTURED XM INT'L. (OR TREE ISLAND WIRE) ICC ER # 2267 - VERIFY WITH VENEER MANUFACTURER. DIVISION 5: METALS, STRUCTURAL AND MISC. SECTION 5-A MISCELLANEOUS AND STRUCTURAL METALS: WORKMANSHIP: ALL WORK SHALL COMPLY WITH A.I.S.C. "MANUAL OF STEEL CONSTRUCTION', LATEST EDITION, UNLESS MORE EXACTING REQUIREMENTS ARE SPECIFIED IN THE CONTRACT DOCUMENTS DR STRUCTURAL DRAWINGS. MATERIALS: A. STRUCTURAL STEEL AND MISCELLANEOUS IRON SHALL CONFORM TD ASTM A 615, A 706 (SEISMIC CATEGORY D) OR A 996. (CRC R404.1.2.3.7) B. DRYER VENT TO OUTSIDE AIR PER MANUFACTURER'S SPECIFICATIONS AND LOCAL JURISDICTIONAL REQUIREMENTS. PIPE: STANDARD STEEL PIPE-ATM A53-69A, GRADE B OR AS SPECIFICALLY NOTED ON THE DRAWINGS. MISCELLANEOUS ITEMS: MISCELLANEOUS METAL ITEMS AND THEIR RELATED COMPONENTS ARE NOT NECESSARILY INDIVIDUALLY DESCRIBED. THE MOST IMPORTANT AND THOSE REQUIRING DETAILED DESCRIPTION ARE SPECIFIED. MISCELLANEOUS ITEMS NOT DESCRIBED SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE INTENT OF THE DRAWINGS AND SPECIFICATION AND AS REQUIRED TO COMPLETE THE WORK. SHOP DRAWINGS, CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF DECORATIVE IRON WORK TO BUILDER FOR REVIEW FOR CONFORMANCE WITH VISUAL DESIGN CONCEPT PRIOR TO FABRICATION. DIVISION 6: WOOD FRAME SECTION 6-A ROUGH CARPENTRY: SEE STRUCTURAL ENGINEER OF RECORD FOR ALL FRAMING MEMBERS AND SPECIFICATIONS. VENTILATION REQUIRED: ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION OF 1/16 INCH (1.6 MM) MINIMUM AND 1/4 INCH (6.4 MM) MAXIMUM. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4 INCH (6.4 MM) SHALL BE PROVIDED WITH, CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF 1/16" MINIMUM AND 1/4" MAX. (CRC R806.1) THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT REDUCTION OF THE TOTAL AREA TO 1/300 IS PERMITTED PROVIDED THAT AT LEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED NO MORE THAN 3 FEET BELOW THE RIDGE WITH THE BALANCE PROVIDED BY EAVE OR CORNICE VENTS. (CRC R806.2) SECTION 6-C WOOD TRUSSES A. THE BUILDER SHALL COORDINATE THE INSTALLATION OF ALL CEILING DROPS WITH THE TRUSS MANUFACTURER AND THE FRAMING CONTRACTOR. 1.LUMBER FOR PREFABRICATED TRUSSES SHALL BE IDENTIFIED BY A GRADE MARK OF A LUMBER GRADING OR INSPECTION AGENCY THAT HAS BEEN APPROVED BY AN ACCREDITATION BODY THAT COMPLIES WITH DOC PS 20. IN LIEU OF A GRADE NARK, A CERTIFICATE OF INSPECTION ISSUED BY A LUMBER GRADING OR INSPECTION AGENCY MEETING THE REQUIREMENTS OF THIS SECTION SHALL BE ACCEPTED. (CRC R802.1) 2.MANUFACTURER SHALL SUPPLY TO THE ARCHITECT/ENGINEER AND CONTRACTOR FOR SUBMITTAL TO THE BUILDING DEPARTMENT CALCULATIONS ANO SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. ALL CALCULATIONS AND SHOP DRAWINGS SHALL BE SIGNED BY A CALIFORNIA REGISTERED ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE MANUFACTURER TO OBTAIN BUILDING DEPARTMENT APPROVAL OF CALCULATIONS AND SHOP DRAWINGS PRIOR TO ISSUANCE OF BUILDING PERMIT. 3.BUILDER SHALL HAVE APPROVED TRUSS PLANS ON THE JOB PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE TRUSS MANUFACTURER SHALL SUBMIT CALCULATIONS, SHOP DRAWINGS, DETAILS, BRIDGING AND ERECTION BRACING SIGNED BY A REGISTERED ENGINEER TO THE BUILDING DEPARTMENT AND STRUCTURAL ENGINEER, FOR THEIR REVIEW PRIOR TO FABRICATION. ONE SET OF SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW FOR CONFORMANCE WITH THE VISUAL DESIGN CONCEPT PRIOR TO TRUSS FABRICATION. B. THE TRUSS MANUFACTURER SHALL BE RESPONSIBLE FOR FRAMING AROUND OPENINGS IN THE ROOF OR FLOOR, SHALL PROVIDE LADDER FRAMING AT NONSTANDARD TRUSS MEMBER SPACING TO KEEP WITHIN THE SPAN RATING OF THE ROOF OR FLOOR SHEATHING AND SHALL SUBMIT DETAILS AND HANGERS AS REQUIRED. C. THE TRUSS MANUFACTURER SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, SIZE AND WEIGHT OF ATTIC LOCATED MECHANICAL EQUIPMENT AND INCORPORATE SUCH INFORMATION INTO THE DESIGN AND CALCULATION OF TRUSSES SUPPORTING IT. D. NON-BEARING WALLS SHALL BE HELD SHORT TO ALLOW FOR RAFTER-TRUSS DEFLECTION WITH CLIPS APPROVED BY THE STRUCTURAL ENGINEER TO STABILIZE THE WALL. E. TRUSS MANUFACTURER SHALL PROVIDE MEMBERS OF ADEQUATE BEARING AREA IN SUCH A WIDTH TO INSURE AGAINST OVERSTRESSING OF SUPPORTING TIMBER, MULTIPLE JOISTS, GIRDERS AND PLATES OR PROVIDE BEARING PLATES AND DETAILS TO DO SAME. F. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE TRUSS MANUFACTURER, FRAMING, ELECTRICAL, PLUMBING AND MECHANICAL CONTRACTORS AT FIRE PROTECTED AREAS TO MAINTAIN REQUIRED FIRE PROTECTION WITHOUT PENETRATIONS UNLESS ALLOWED BY CODE AND LOCAL JURISDICTION. G. WHERE TRUSS FRAMING AND CONVENTIONAL FRAMING OCCUR TOGETHER IN A CONTINUOUS ROOF PLANE, THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE TRUSS MANUFACTURER AND FRAMING CONTRACTOR TO ELIMINATE DIFFERENTIAL DEFLECTION BETWEEN THE TRUSS AND CONVENTIONAL FRAMING MEMBERS. H. WHERE TRUSS FRAMING AND CONVENTIONAL FRAMING OCCUR TOGETHER IN THE SAME ROOF, THE PLATE HEIGHT AS NOTED WILL BE MAINTAINED FOR THE DEEPER CONVENTIONAL MEMBER WITH THE BOTTOM TRUSS CHORD MATCHING THE RAFTER SEAT CUT. TRUSS MANUFACTURER SHALL PROVIDE HEEL AS REQUIRED TO MAINTAIN A CONTINUOUS ROOF PLANE ALIGNMENT. SECTION 6 - B FINISH CARPENTRY: MILLWORK: MANUFACTURE MILLWORK AND CASEWORK PER MANUAL OF MILLWORK AND WOODWORK INSTITUTE OF CALIFORNIA, CUSTOM GRADE UNLESS NOTED OTHERWISE. INSTALLATION: INSTALL ALL SHELVING, CASEWORK, MILLWORK, DOORS, HARDWARE, RAILING, TRIM, COUNTERS, UTILITY BACKBOARDS AND OTHER FINISH CARPENTRY. DIVISION 7: ROOFING INSTALL ROOFING MATERIAL AS PER CODE AND MANUFACTURERS RECOMMENDATIONS SECTION 7-A ROOFING AND MEMBRANES: SCOPE: FURNISH AND INSTALL ROOFING AND WATERPROOFING WORK COMPLETE, INCLUDING CANT STRIPS AND INCORPORATING OTHER TRADES FLASHING, SLEEVES AND JACKS. INSTALLATION: INSTALL ROOFING AND ALL CORROSION RESISTANT METAL FLASHING PER MANUFACTURER'S RECOMMENDATIONS INCLUDING THE USE OF FASTENERS AND ANCHORING DEVICES IN HIGH WIND AREAS, AND PER CRC, CHAPTER 9, CAREFULLY INCORPORATING FLASHING SCUPPERS, JACKS, SLEEVES, ROOF DRAINS, SKYLIGHTS, ETC., SUPPLIED BY OTHERS. ROOFING CONTRACTOR SHALL BE RESPONSIBLE FOR THE WEATHER-TIGHT INTEGRITY OF THE ENTIRE ROOFING SYSTEM, INCLUDING, BUT NOT LIMITED TO, MEMBRANES, ROOFING, WALL/ROOF FLASHINGS, JACKS, VENTS, UNDERLAYMENT AND SHEATHING. UNDERLAYMENT SHALL CONFORM TO ASTM D226 TYPE I, ASTM 4869 TYPE I, OR ASTM D6757 SELF-ADHERING POLYMER MODIFIED BITUMEN SHEET SHALL COMPLY WITH ASTM D 1970. DIVISION 7: ROOFING, CONT. SPECIAL CONDITIONS: A. PROVIDE CANT STRIPS AT ALL VERTICAL SURFACES. B. PROVIDE CRICKETS AS INDICATED, AND AS NECESSARY FOR PROPER WATER DRAINAGE AND TO REDIRECT CHANNELED OR RUNOFF WATER AWAY FROM VERTICAL SURFACES. MATERIALS: REFER TO PLANS FOR TYPE AND MANUFACTURER OF ROOFING. ROOF DRAINAGE: UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF ALL ROOF PER CRC 903.4 AND R903.4.1 SECTION 7-B SHEET METAL: MEASUREMENTS: VERIFY ALL DIMENSIONS SHOWN ON DRAWINGS BY TAKING FIELD MEASUREMENTS; PROPER FIT AND ATTACHMENT ON ALL PARTS IS REQUIRED. STANDARDS: ALL WORK INCLUDED IN THIS SECTION SHALL BE PERFORMED IN A WEATHER TIGHT MANNER CONSISTENT WITH GOOD ROOFING AND WEATHERPROOFING PRACTICE. FOLLOW SIDING, WINDOW AND ROOFING MANUFACTURERS' GUIDELINES. FLASHING AND COUNTER FLASHING: EXTERIOR OPENINGS EXPOSED TO THE WEATHER SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WEATHERPROOF. FLASHING AND COUNTER FLASHING SHALL BE PROVIDED AT ALL JUNCTION OF ALL ROOF AND VERTICAL SURFACES (WALLS, ETC.) PER CRC SECTION R903.3. ALL PARAPETS SHALL BE PROVIDED WITH COPING OF APPROVED MATERIALS. ALL FLASHING, COUNTER FLASHING AND COPING, WHEN OF METAL, SHALL BE OF NOT LESS THAN NO. 26 U.S. GAUGE CORROSION-RESISTANT METAL PER CRC R903.3. AN EAVE DRIP EDGE SHALL BE PROVIDED AT EAVES AND GABLES OF SHINGLE ROOFS. ADJACENT PIECES OF DRIP EDGE SHALL BE OVERLAPPED A MINIMUM OF 2". DRIP EDGES SHALL EXTEND A MINIMUM OF 1/4" BELOW THE ROOF SHEATHING AND EXTEND UP THE ROOF DECK A MINIMUM OF 2". DRIP EDGES SHALL BE MECHANICALLY FASTENED TO ALL ROOF DECK AT A MAXIMUM OF 12 INCHES O.C. WITH FASTENERS PER CRC SEC. R905.1.S. UNDERLAYMENT SHALL BE INSTALLED OVER ALL DRIP EDGE ALONG EAVES AND UNDER THE UNDERLAYMENT ON GABLES. U.N.O BY THE SHINGLE MANUFACTURER, SHINGLES ARE PERMITTED TO BE FLUSH WITH THE DRIP EDGE. CRC R905.2.8.5 ROOF VALLEY FLASHINGS SHALL BE PROVIDED FOR SHINGLES AS FOLLOWS: A. ASPHALT SHINGLES, THE ROOF VALLEY FLASHING SHALL BE THE SAME AS REQUIRED FOR WOOD SHINGLES OR SHALL BE OF LACED ASPHALT SHINGLES APPLIED IN AN APPROVED MANNER WILL, AN UNDERLAYMENT OF NOT LESS THAN TYPE 30 FELT EXTENDING 18 INCH FROM THE CENTER LINE EACH WAY. * ALL VALLEYS SHALL BE CLOSED / WOVEN TYPE B. CLAY AND CONCRETE TILE, THE ROOF VALLEY FLASHING SHALL BE PROVIDED OR NOT LESS THAN 26 GA. GALVANIZED SHEET CORROSION-RESISTANT METAL APPLIED OVER AN UNDERLAYMENT OF NOT LESS THAN 30/ A.S.T.M. FELT. THE METAL SHALL EXTEND AT LEAST 12 INCH FROM THE CENTERLINE EACH WAY AND SHALL HAVE A SPLASH DIVERTER RIB NOT LESS THAN 1 INCH HIGH AT THE FLOW LINE FORMED AS PART OF THE FLASHING. SECTIONS OF FLASHING SHALL HAVE AN END LAP OF NOT LESS THAN 4 INCH. DO NOT NAIL GREATER THAN 1 INCH INTO ANY VALLEY, DO NOT BLOCK WITH BATTENS. USE BATTEN EXTENDER, WIRE TIES, OR OTHER TO COMPLY WITH THIS REQUIREMENT. USE CRIMPED EDGES WHERE UNDERLAYMENT FELTS ARE INSTALLED OVER VALLEY METAL ALL COMPONENTS SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS AND ICC REPORT. FLASH AND COUNTER FLASH AT ALL ROOF TO WALL CONDITIONS. G.I. FLASH AND CAULK WOOD BEAMS AND OUTLOOKERS PROJECTED THROUGH EXTERIOR WALLS OR ROOF SURFACES PROVIDE SOLID BLOCKING AROUND BEAM PENETRATIONS FOR SUPPORT OF METAL FLASHING COLLARS. WHERE EXPOSED TO WEATHER, FLASH ALL HORIZONTAL WOOD TRIM BUTTING TO EXTERIOR FINISH. WORKMANSHIP: 1. WORK SHALL BE ACCURATELY FABRICATED TO MATCH DETAIL AND FITTED TO JOB CONDITIONS. 2. MOLDED AND BRAKE-FORMED MEMBERS SHALL BE FINISHED TRUE AND STRAIGHT WITH SHARP LINES AND ANGLES. 3. LOCK SEAMS FLAT AND TRUE TO LINE, 1/2 INCH WIDE, SWEATED FULL WITH SOLDER WHERE OVERLAPPING DOES NOT PROVIDE WATER TIGHT CONNECTION. * ALTERNATE - USE A SEALANT SUCH AS VULKEM 116 WITH A 4-INCH MINIMUM OVERLAP. 4. SHEET METAL WORK SHALL BE DESIGNED TO PROVIDE COMPLETE WEATHER TIGHT AND WATERPROOF CONNECTIONS. 5. ALL GALVANIZED METAL SHALL BE SHOP PRIMED WITH ONE COAT OF ZINC DUST-ZINC OXIDE PRIMER OVER ALL SURFACES AND AS RECOMMENDED BY METAL SPECIALIST. 6. SHEET METAL USED AS FLASHING ADJACENT TO WOOD SURFACES SHALL BE SET IN HIGH QUALITY SEALANT TO INSURE WATERPROOFING BETWEEN SUCH MATERIALS. F.A.U.COMBUSTION AIR: PROVIDE COMBUSTION AIR PER MANUFACTURER'S SPECIFICATIONS AND CMC CHAPTER 7. DRYER VENTS, VENT DRYER TO OUTSIDE AIR WILL, MINIMUM 4 INCH DIAMETER SMOOTH, METAL DUCT WITH BACK DRAFT DAMPER PER CMC 504.3. MANUFACTURERS SPECIFICATIONS AND LOCAL JURISDICTIONAL REQUIREMENTS. LENGTH LIMITATION. UNLESS OTHERWISE PERMITTED DR REQUIRED BY THE MANUFACTURE'S INSTALLATION INSTRUCTIONS AND APPROVED BY THE BUILDING OFFICIAL, DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90-DEGREE ELBOWS. TWO FT TO BE DEDUCTED FOR EACH 90-DEGREE ELBOW IN EXCESS OF TWO. CMC 504.3.2.2 SECTION 7-C INSULATION: SEE ENERGY COMPLIANCE SHEET FOR CALIFORNIA ENERGY TITLE 24 REQUIREMENTS. 1. THE FOLLOWING OPENINGS IN THE BUILDING ENVELOPE MUST BE CAULKED, SEALED OR WEATHER-STRIPPED. A. EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALL PANELS, WALL SOLE PLATES AND FLOORS. B. OPENINGS FOR PLUMBING, ELECTRICAL AND GAS LINES IN EXTERIOR AND INTERIOR WALLS, CEILINGS AND FLOORS. C. OPENINGS IN THE ATTIC FLOOR (SUCH AS WHERE CEILING PANELS MEET INTERIOR AND EXTERIOR WALLS AND MASONRY FIREPLACES). D. ALL OTHER SUCH OPENINGS IN THE BUILDING ENVELOPE. ALTERNATIVE APPROVED TECHNIQUES MAY BE USED TO MEET THE STANDARD CAULKING REQUIREMENTS FOR EXTERIOR WALLS INCLUDING, BUT NOT LIMITED TO, CONTINUOUS STUCCO, CAULKING OR TAPING OF ALL JOINTS BETWEEN WALL COMPONENTS (E.G., BETWEEN SLATS IN WOOD SLAT WALLS), BUILDING WRAPS OR RIGID WALL INSULATION. DIVISION 7: ROOFING, CONT. 2. BUILDER AND INSULATION INSTALLER ARE TO PROVIDE A CERTIFICATE OF INSULATION AND POST IN THE BUILDING IN A CONSPICUOUS LOCATION. 3. SEE PLANS FOR PARTY WALL CONDITIONS WHERE OCCURS. EXTERIOR WALL COVERINGS: WATER RESISTIVE BARRIER (WRB) SHALL BE PROVIDED BEHIND THE EXTERIOR FINISH OF EXTERIOR WALLS. PROVIDE 1 LAYER OF #15 ASPHALT FELT, COMPLYING WITH ASTM D 226 OR OTHER APPROVED WRB OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. SEC R703.2. WHERE PLASTER IS APPLIED OVER WOOD BASED SHEATHING, THE WRB SHALL INCLUDE A VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO 2 LAYERS OF GRADE D PAPER PER CRC R703.6.3. MATERIALS: ALL EXTERIOR MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE CRC, APPLICABLE EDITION, STATE AND LOCAL CODES. WHERE HARDBOARD SIDING IS USED FOR COVERING THE OUTSIDE OF EXTERIOR WALLS, IT SHALL CONFORM TO THE CRC, APPLICABLE EDITION, STATE AND LOCAL CODES. LAP SIDING SHALL BE INSTALLED HORIZONTALLY AND APPLIED TO SHEATHED OR UNSHEATHED WALLS. CORNER BRACING SHALL BE INSTALLED TO CONFORM WITH CRC REQUIREMENTS. A WEATHER-RESISTIVE BARRIER (15# BUILDING PAPER) SHALL BE INSTALLED UNDER LAP SIDING. ALL FASTENERS USED FOR THE ATTACHMENT OF SIDING SHALL BE HOT DIPPED GALVANIZED STAINLESS STEEL, COPPER OR ALUMINUM. NAIL SIZE AND SPACING SHALL MEET CRC REQUIREMENTS AND SHALL PENETRATE FRAMING 1 1/2 INCH. LAP SIDING SHALL OVERLAP 1 INCH MINIMUM AND BE NAILED THROUGH BOTH COURSES AND INTO FRAMING MEMBERS WITH NAILS LOCATED 1/2 INCH FROM BOTTOM OF THE OVERLAPPED COURSE, OR TO MANUFACTURER'S SPECIFICATIONS. BALCONY AND DECK: DECKS, BALCONIES, LANDINGS, EXTERIOR STAIRWAYS AND SIMILAR SURFACES EXPOSED TO THE WEATHER SHALL BE FULLY PAINTED AND SEALED. ALL EXTERIOR DECKS AND BALCONIES EXPOSED TO WEATHER SHALL BE CONSTRUCTED WITH SUFFICIENT SLOPE (MINIMUM 3/8 INCH PER FOOT) TO ENSURE ADEQUATE DRAINAGE. UNLESS REQUIRED TO BE ACCESSIBLE, PROVIDE A MINIMUM 2 INCH DROP FROM FINISHED INTERIOR FLOOR TO THE HIGHEST FLOOR LEVEL ON ANY ADJOINING DECK OR BALCONY. BUILDER SHALL BE RESPONSIBLE FOR THE WEATHER INTEGRITY OF THE ENTIRE HORIZONTAL MEMBRANE, INCLUDING TRANSITION FLASHINGS, PENETRATIONS, ETC. COATING THICKNESS SHALL BE AT LEAST THAT AS REQUIRED BY MANUFACTURER. NO REFLECTIVE SEAMS IN PLY OR METAL SHALL BE VISIBLE UPON COMPLETION. DIVISION 8: DOORS, WINDOWS AND GLASS ALL EXTERIOR DOORS AND WINDOW ASSEMBLIES SHALL COMPLY WITH THE REQUIREMENTS OF CRC SECTION R612.6 (DESIGN PRESSURE RATING), AND SHALL BE LABELED STATING THE NAME OF THE MANUFACTURER AND THAT THE ASSEMBLY CONFORMS TO AAMA/WDMA/CSA101/I.S.2/A440. GLASS AND GLAZING SHALL BE DESIGNED TO RESIST WIND LOADS IN CRC SEC. R301.1 FOR COMPONENTS AND CLADDING. LOAD RESISTANCE SHALL BE DETERMINED IN ACCORDANCE WITH ASTM 1300. CBC SEC. 2404.1 SECTION 8-A WOOD DOORS: STANDARDS: ALL DOORS SHALL COMPLY WITH REQUIREMENTS OF THE WOODWORK INSTITUTE OF CALIFORNIA, STANDARD GRADE (U.N.O.): TITLE 24, CALIFORNIA ADMINISTRATIVE CODE. SCOPE: FURNISH AND INSTALL ALL DOORS COMPLETE AS INDICATED ON PLANS. THE GENERAL CONTRACTOR SHALL COORDINATE DOOR SUPPLIER AND FRAMING CONTRACTOR FOR INSTALLATION OF ALL DOORS. STANDARDS AND INSTALLATION: PER MANUFACTURER'S INSTALLATION RECOMMENDATIONS. ALL EXTERIOR DOORS SHALL COMPLY WITH MANDATORY STATE INFILTRATION STANDARDS. MEASUREMENTS: VERIFY ALL DIMENSIONS BY TAKING FIELD MEASUREMENTS PRIOR TO INSTALLATION. TYPE & SIZES: AS INDICATED IN DRAWINGS. MATERIALS: A. GLASS IN HAZARDOUS AREAS, PROVIDE TEMPERED GLASS PER CRC SEC R308 AND AS INDICATED IN DRAWINGS AND AS NECESSARY. ALL GLASS IN OPERABLE DOORS SHALL BE TEMPERED. B. ENTRY DOORS, 1 3/4 INCH THICK SOLID WOOD, EXTERIOR GRADE. AS SELECTED BY OWNER. C. INTERIOR DOORS, 1 3/8 INCH THICK HARDBOARD, HOLLOW CORE, AS SELECTED BY OWNER. D. BI-PASS WARDROBE. 1 1/8 INCH THICK HARDBOARD, HOLLOW CORE. E. BI-PASS MIRROR, AS SELECTED BY OWNER. F. BI-FOLD DOORS, TO MATCH TYPICAL INTERIOR DOORS. LOUVERED. G. FRENCH DOORS, 1 3/4 INCH THICK METAL WITH DIVIDED LITES AS INDICATED ON EXTERIOR ELEVATIONS. H. GARAGE DOOR TO LIVING UNIT AT OCC. SEPARATION, SELF-CLOSING, SELF LATCHING, SOLID WOOD OR METAL HONEYCOMB, 1 3/8 INCHES IN THICKNESS (OR SELF-CLOSING SELF LATCHING DOOR HAVING A FIRE PROTECTION RATING OF NOT LESS THAN 20 MINUTES PER CRC R302.5.I IF BOTH RESIDENCE AND GARAGE ARE SPRINKLERED, DOORS NEED ONLY BE SELF-CLOSING AND SELF-LATCHING. R302.5.1 I. 1 3/4 INCH THICK METAL 1-1/2 HR. FIRE RATED ASSEMBLY AT 2-HR. OCCUPANCY SEPARATION. SECTION 8-B VINYL DOORS AND WINDOWS SCOPE: FURNISH AND INSTALL ALL VINYL DOORS AND WINDOWS COMPLETE AS INDICATED ON PLANS. THE GENERAL CONTRACTOR SHALL COORDINATE WINDOW SUPPLIER AND FRAMING CONTRACTOR FOR INSTALLATION OF ALL WINDOWS AND DOORS. STANDARDS AND INSTALLATION: PER MANUFACTURER'S INSTALLATION RECOMMENDATIONS. ALL WINDOWS AND DOORS SHALL COMPLY WITH MANDATORY STATE INFILTRATION STANDARDS. ALIGN BOTTOM OF HEADERS AT ALL ADJACENT WINDOWS AND DOORS UNLESS NOTED OTHERWISE ON PLANS. MEASUREMENTS: VERIFY ALL DIMENSIONS BY TAKING FIELD MEASUREMENTS PRIOR TO INSTALLATION. TYPE & SIZES, AS INDICATED ON THE DRAWINGS. SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO A0.2 GENERAL NOTES AND SPECIFICATIONS DIVISION 8: DOORS, WINDOWS AND GLASS, CONT. MATERIALS: A. GLASS IN HAZARDOUS AREAS, PROVIDE TEMPERED GLASS PER CHAPTER R308 CRC REQUIREMENTS, AS INDICATED IN DRAWINGS AND AS NECESSARY. ALL OPERABLE DOORS TO BE TEMPERED. B. VINYL SLIDING DOORS, COMPLETE WITH NYLON SCREEN: FINISH TO MATCH DOOR FRAME. C. VINYL OPERABLE WINDOWS: COMPLETE WITH VINYL SCREEN, FINISH TO MATCH WINDOW FRAMES. D. FIXED SASH, MATCH OPERABLE WINDOWS. EGRESS: MANUFACTURER SUPPLIER SHALL PROVIDE WINDOWS THAT MEET ALL EMERGENCY EXITING REQUIREMENTS OF THE CRC SEC. R310 AND NOTIFY ARCHITECT IF DRAWINGS ARE IN CONFLICT PRIOR TO FABRICATION OR DELIVERY. LIGHT AND VENTILATION: MINIMUM OPENABLE AREA TO THE OUTDOORS SHALL BE 4 PERCENT OF THE FLOOR AREA BEING VENTILATED PER CRC SEC. R303 SECTION 8-C: GLASS AND GLAZING GLASS AND GLAZING SHALL BE DESIGNED TD RESIST WIND LOADS IN CRC TABLE R301.2(2), ADJUSTED FOR HEIGHT AND EXPOSURE IN ACCORDANCE WITH TABLE R301.2(3) CRC R612.2 SCOPE: FURNISH AND INSTALL ALL GLAZING AND MIRRORS OTHER THAN FACTORY GLAZED DOOR AND WINDOWS. GLAZING SHALL BE DONE DURING FINISH WORK. IF MIRRORED WARDROBE DOORS ARE USED, SAFETY GLAZING IS REQUIRED. STANDARDS: GLASS AND GLAZING AS PER CHAPTER 3 OF THE CRC AND ENERGY COMPLIANCE CALCULATIONS. MATERIALS: A. GLASS IN HAZARDOUS AREAS, PROVIDE TEMPERED GLASS PER CRC SEC R308 REQUIREMENTS, AS INDICATED IN DRAWINGS AND AS NECESSARY. ALL OPERABLE DOORS TO BE TEMPERED. B. FIXED AND OPERABLE WINDOWS, AS PER T-24 RECOMMENDATIONS C. DOORS: 3/16 INCH THICK TEMPERED GLASS. DUAL GLAZED TYPICAL. DIVIDED LITES AS SHOWN ON EXTERIOR ELEVATIONS. D. MIRRORS: 1/4 INCH POLISHED PLATE. SEE INTERIOR ELEVATIONS FOR SIZE. E. SHOWER ENCLOSURES: APPROVED TEMPERED, SHATTER PROOF, OBSCURE. PER CRC TABLE 308.3.1(1) MIRRORED WARDROBE F. DOORS: SAFETY GLASS PER CRC R308.3, EXEMPT IF MOUNTED OR HUNG ON A SURFACE THAT PROVIDES CONTINUOUS BACKING SUPPORT. G. CAULKING COMPOUND, GUN APPLIED, NON-HARDENING, NON-MILDEWING. SECTION 8-D WEATHER-STRIPPING AND THRESHOLDS EXTERIOR DOORS: SHALL BE COMPLETELY WEATHER-STRIPPED WITH MORTISE-TYPE AS MANUFACTURED BY "PEMKO" OR OWNER SELECTED SUBSTITUTE. THRESHOLDS: ALUMINUM, BRONZE ANODIZED, TO MEET ALL APPLICABLE DISABLED ACCESSIBLE ROUTE REQUIREMENTS WHERE REQUIRED. SECTIONAL GARAGE DOORS: 1. GARAGE DOOR TYPE, MODEL, COLOR AND FINISH SHALL BE SELECTED BY THE OWNER. 2. SPRING MUST BE CONTAINED WITH A RESTRAINT DEVICE TO ANCHOR THE SPRING OR ANY PART THEREOF IN THE EVENT IT FRACTURES. 3. BOTH THE SPRING AND THE RESTRAINT DEVICES MUST BE IDENTIFIED AS CONFORMING TO THE REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT. DIVISION 9: FINISHES SECTION 9-A STUCCO SCOPE: FURNISH AND INSTALL ALL PLASTERING WORK COMPLETE, INCLUDING GROUNDS, SCREEDS, EXPANSION JOINTS, CASING, CORNER GUARDS, ETC. STANDARDS: A. ALL WORK SHALL COMPLY WITH CHAPTER 6 OF THE CRC B. ALL WORK SHALL COMPLY WITH THE INSTALLATION STANDARDS OF THE MANUFACTURER OF THE PLASTER INSULATION PRODUCTS PROVIDED. C. ALL WORK SHALL COMPLY WITH APPLICABLE STANDARDS OF "LATHING AND PLASTERING REFERENCE SPECIFICATIONS" OF THE REGIONAL LATHING AND PLASTERING CONTRACTOR'S ASSOCIATION. D. APPLICATION OF WEATHERPROOF BARRIER SHALL BE THE RESPONSIBILITY OF CONTRACTOR BASED ON RECOMMENDATIONS OF THE STUCCO MANUFACTURING REPRESENTATIVE. E. FINISH: COLOR AND FINISH AS SELECTED BY OWNER. PROVIDE ARCHITECT WITH MINIMUM 24 INCH X 24 INCH FIELD APPLIED SAMPLE PRIOR TO FIELD APPLICATION. F. EXPOSED CONCRETE FOUNDATION, FINISH COLOR COAT ALL EXPOSED SURFACES. MATERIALS: 7/8 INCH STUCCO A. REFERENCE SPECIFICATIONS: LATHING MATERIALS AND THEIR APPLICATION AND PLASTER MATERIALS AND THEIR APPLICATION SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE SECTIONS FOR LATHING, FURRING AND PLASTERING OF THE NATIONAL GYPSUM ASSOCIATION. ALL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION-RESISTANT MATERIALS. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1-1/2” LONG, 11 GAGE NAILS HAVING A 7/16" HEAD, OR 7/8" LONG, 16 GAGE STAPLES, SPACED NO MORE THAN 6". PORTLAND CEMENT PLASTER SHALL BE NOT LESS THAN 3 COATS WHEN APPLIED OVER METAL LATH OR WIRE LATH PER CODE SECTION R703.6.1 & 703.6.2. B. WIRE MESH, X-CELL 17 GAUGE STUCCO NETTING ICBO (ESR #1786) BY XM INTERNATIONAL [CRC R703.6] C. BUILDING PAPER: INSTALL MIN. "60 MINUTE” BUILDING PAPER UNDER EXTERIOR TRIM AND SIDING. APPLY SO AS TO FORM A WEATHER TIGHT MEMBRANE. OVERLAP EACH COURSE BELOW 2 INCH MINIMUM HORIZONTAL JOINTS AND 6 INCH MINIMUM AT VERTICAL JOINTS. WATER RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED SHEATHING, SHALL INCLUDE A WATER-RESISTIVE VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER PER SECTION R703.6.3. DIVISION 9: FINISHES, CONT. D. FLASHING AT WALL PENETRATIONS, INSTALL A 4-HOUR RATED FLASHING PAPER AS MANUFACTURED BY FORTIFIBER (E.G.,MOISTOP) AS FLASHING IN A WEATHERBOARD FASHION. SLIP WINDOW UNDER HORIZONTAL HEAD MOISTOP AND SECURE METAL WINDOW AND DOOR FIN OVER MOISTOP AT SIDES AND BOTTOM. NOTE: PROVIDE A HEAD OF BUTYL SEALANT ON INTERFACE OF FINS AT TOP AND BOTTOM. AAMA GUIDELINES AND/OR DETAIL SHOWING PROPER LAP OF FLASHING PAPER WITH THE FOLLOWING EXCEPTIONS WINDOW TO BE SET IN FULL BED OF SEALANT. NO BUILDING PAPER BREAKS ABOVE, BELOW, AND WITHIN 24-INCHES OF OPENINGS. ALL PENETRATIONS SUCH AS WATER AND GAS PIPES TO BE SEALED TO PAPER WITH SEALANT. E. MINIMUM 0.019", CORROSION-RESISTANT WEEP SCREED OR PLASTIC SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2" SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON THE EXTERIOR STUD WALLS IN ABOVE EARTH AND/OR 2" ABOVE PAVED AREAS AND SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE WEATHER-RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE WEATHER RESISTIVE BARRIER AND EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE SCREED. CRC SEC. R703.6.2.1 SECTION 9-B GYPSUM WALLBOARD & CEILING BOARD SCOPE: FURNISH AND INSTALL ALL GYPSUM WALLBOARD WORK COMPLETE. VERIFY ALL SPECIALTY MATERIALS, NAILING AND INSTALLATION SEQUENCING AT SOUND/FIRE ASSEMBLIES AND STRUCTURAL SHEAR WALLS PRIOR TO COMMENCING WORK. STANDARDS: A. ALL WORK TO COMPLY WITH, CHAPTER 3 OF THE CRC B. ALL WORK AND MATERIALS SHALL COMPLY WITH, GYPSUM ASSOCIATION'S "RECOMMENDED SPECIFICATIONS FOR THE APPLICATION AND FINISHING OF GYPSUM WALLBOARD." WORKMANSHIP: ALL WORKMANSHIP SHALL BE INSPECTED AND APPROVED BY THE BUILDER OR BUILDERS REPRESENTATIVE. SPECIAL FINISHES SHALL BE PRE-DETERMINED BY CONTRACT WITH BUILDER AND SUB. A. ALL JOINTS IN FINISHED SURFACES SHALL BE TAPED AND FINISHED WITH JOINT COMPOUND. B. PROVIDE METAL TRIM AT ALL EXPOSED EDGES AND EXTERNAL CORNERS. C. METAL TRIM SHALL BE TIGHT TO WALLBOARD EDGES, PLUMB, LEVEL AND TRUE TO PLANE, SECURELY ATTACHED. D. CONCEAL EXPOSED NAIL OR SCREW HEADS WITH JOINT COMPOUND. E. PROTECT ALL EXPOSED WOOD BEAMS, POST, RAILINGS ETC. F. ALL GYPSUM WALLBOARD AT TUBS TO BE INSTALLED IN SUCH A MANNER THAT WHERE ARE NO SURFACES OUT OF ALIGNMENT WITH ADJACENT SURFACES AND THE TRUE PLANE OF THE WALL IS MAINTAINED. MATERIALS: A. GYPSUM WALLBOARD AND CEILING BOARD: 1/2 INCH THICK THROUGHOUT UNLESS NOTED OTHERWISE. B. GYPSUM WALLBOARD AND CEILING BOARD: 5/8 INCH THICK, FIRE RATED "X" WITH TAPED JOINTS AT FIRE/SOUND RATED WALLS AS DETAILED AND AT OTHER WALLS AND CEILINGS WHERE NOTED ON DRAWINGS. PROVIDE MULTIPLE LAYERS AS DETAILED WITH NAILS SIZED ACCORDINGLY. C. AT CEILINGS: PROVIDE 5/8 INCH GYPSUM WALLBOARD WHEN FRAMING SPACING EXCEEDS 16 INCH O.C. D. MOISTURE RESISTANT WALLBOARD AND CEILING BOARD: USE IN WET AREAS AS RECOMMENDED BY GYPSUM BOARD MANUFACTURER. E. PROVIDE WATER RESISTANT GYPSUM BOARD UNDER TUB AND SHOWER ENCLOSURE MATERIALS TO A HEIGHT OF 3O INCHES MINIMUM ABOVE DRAIN INLET. MAINTAIN GAP BETWEEN FACTORY EDGE AND ALL TUBS, SHOWER RECEPTORS TO ENSURE FULL SEALANT APPLICATION BY CERAMIC TILE INSTALLER. F. EXTERIOR USE: EXTERIOR GRADE FIRE RATED, FOR AREAS SUBJECT TO MOISTURE AT FIRE ASSEMBLIES AS DETAILED. G. METAL CORNER BEAD, CASING AND TRIM - GALVANIZED AND NAILED 1) L-SHAPED TRIM AT EXPOSED EDGES TYPICAL. 2) BULLNOSE CORNER BEAD AT EXTERNAL CORNERS H. RESILIENT CHANNELS: PROVIDE AT FIRE/SOUND RATED FLOOR/CEILING ASSEMBLIES AS DETAILED. I. TAPE AND COMPOUND: AS RECOMMENDED BY GYPSUM BOARD MANUFACTURER FOR USE SPECIFIED. SECTION 9-C FLOORING RESILIENT FLOORING SCOPE: FURNISH AND INSTALL ALL RESILIENT FLOORING MATERIAL COMPLETE AS SCHEDULED. J. SUB-FLOORS SHALL BE CLEAN, FREE OF DUST AND DRY, LEVEL AND SMOOTH. K. SURFACES SHALL BE PRIMED AS RECOMMENDED BY THE MANUFACTURER. L. MATERIALS SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. M. ENSURE ADEQUACY OF FLOOR PLANE PRIOR TO INSTALLATION NOTIFY OWNER OF ANY SUBSTANDARD CONDITION PRIOR TO APPLICATION. N. VERIFY ACCEPTABILITY OF CONCRETE SURFACES FOR ALKALINITY PRIOR TO INSTALLATION. MATERIALS: A. VINYL SHEETING: AS SELECTED BY OWNER. B. ADHESIVES: AS RECOMMENDED BY THE MANUFACTURER OF THE FLOOR COVERING. C. PROVIDE POSITIVE SLOPE AT TILE SEATS WITHIN SHOWERS AND AT FLOOR TOWARDS FLOOR DRAIN. NOTE: CHANGES IN FLOOR MATERIAL SHALL OCCUR AT THE CENTERLINE OF THE DOOR BETWEEN ADJACENT ROOMS, UNLESS INDICATED OTHERWISE ON PLANS. DIVISION 9: FINISHES, CONT. SECTION 9-D TILE SCOPE: FURNISH AND INSTALL TILE, GROUT, MASTIC, MORTAR, SEALER ETC. COMPLETE. WORK SHALL BE CLEAN, PLUMB, LEVEL, EXCEPT AT AREAS INTENDED TO DRAIN, TRUE TO LINE WITH CONSISTENT JOINTS. INSTALLATION: A. TILE ON FLOOR. SLAB OR WOOD FRAME SHALL BE INSTALLED PER THE CERAMIC TILE INSTITUTE STANDARDS AND TILE COUNCIL OF AMERICA STANDARDS. B. INSTALL MUD SET TILE AT COUNTERS. TUBS AND SHOWERS PER THE CERAMIC TILE INSTITUTE AND TILE COUNCIL OF AMERICA STANDARDS. C. PROVIDE WATERPROOF MEMBRANE BENEATH TILE OVER WATER RESISTANT BACKING BOARD AS RECOMMENDED BY MANUFACTURER AND CERAMIC TILE INSTITUTE AND TILE COUNCIL OF AMERICA STANDARDS AT ALL AREAS SUBJECT TO MOISTURE AND WATER 'IE.,TUBS/SHOWERS.' MATERIALS: A. TILE AND GROUT AS SELECTED BY OWNER. B. INSTALLATION OF GROUTED TILE FLOORING IS NOT RECOMMENDED OVER WOOD FRAMED FLOOR SYSTEMS. SECTION 9-E LAMINATE PLASTIC FINISHES LAMINATE PLASTIC: FORMICA, WILSON ART OR NEVAMAR. 1/16 INCH GENERAL PURPOSE GRADE 10. APPLICATION: LAMINATE PLASTIC SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. SPLASHES SHALL BE FULLY FORMED (U.N.O.). RANGE CUTS AND COUNTERS SHALL BE SELF-EDGED (U.N.O.). SECTION 9-F COUNTER TOPS: MATERIALS SHALL BE INDICATED ON INTERIOR ELEVATIONS. COLORS SHALL BE SELECTED BY OWNER. SECTION 9-G PAINTING AND FINISHING SCOPE: PROVIDE PAINTING WORK AS INDICATED AND SPECIFIED, COMPLETE INCLUDING PREPARATION OF SURFACES OTHER THAN THOSE THAT ARE FACTORY PRIMED. WORKMANSHIP: A. EACH COAT SHALL BE UNIFORMLY APPLIED, WELL BRUSHED OUT AND FREE OF BRUSH MARKS, RUNS, SAGS OR SKIPS. B. PAINT FINISHES SHALL BE CUT SHARPLY TO LINE, PROTECT ADJACENT SURFACES. C. MIX AND APPLY PAINT AND STAINS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. D. HARDWARE SHALL BE MASKED OR REMOVE PRIOR TO PAINTING OR STAINING. E. SUBCONTRACTOR WILL BE RESPONSIBLE FOR ANY DAMAGE RESULTING FROM OVERSPRAY, AND ALL NECESSARY CLEAN-UP. F. SEMI-GLOSS PAINT TO BE ROLLER OR BRUSH APPLIED. PREPARATION OF SURFACES: A. SURFACES SHALL BE CLEAN AND DRY, AND IN SUITABLE CONDITION FOR FINISH SPECIFIED. REMOVE ALL OIL, GREASE, BOND BREAKING AGENTS, DUST, MILL SCALE AND EFFLORESCENCE. B. CRACKS, HOLES, AND KNOTS SHALL BE FILLED, SANDED SMOOTH AND SEALED. WOOD SURFACES, EXCEPT RESAWN WOOD, SHALL BE SANDED PERFECTLY SMOOTH. SANDING DUST SHALL BE COMPLETELY REMOVED. C. TRIM AND OTHER FINISH WORK SHALL BE PRIMED PRIOR TO INSTALLATION, TO MINIMIZE INCONSISTENT SHRINKAGE. MATERIALS: A. SUBMIT LIST OF MATERIALS AND MANUFACTURERS FOR OWNERS AND ARCHITECTS REVIEW. B. ALL MATERIALS SHALL BE DELIVERED TO THE SITE IN SEALED ORIGINAL MANUFACTURER'S CONTAINERS. C. STAIN COLOR SHALL BE SELECTED BY OWNER. D. PAINT SHALL BE MANUFACTURED BY "DUNN EDWARDS" OR EQUAL, OR OWNERS SELECTED SUBSTITUTE. COLORS: TO BE SELECTED BY ARCHITECT. EXTERIOR PAINTING AND STAINING: A. EXTERIOR EXPOSED CONCRETE AND MASONRY: TWO COATS MASONRY PAINT. B. EXTERIOR WOOD, INCLUDING SIDING, GARAGE DOORS, RAILINGS, FASCIA, EXPOSED BEAMS, ALL TRIM, ETC, SHALL RECEIVE A MINIMUM OF ONE COAT OF PRIMER AND ONE TO TWO COATS FINISH, OR, AS SPECIFIED IN CONTRACT. C. EXPOSED METAL, INCLUDING VENT PIPES, EXHAUST VENTS, HEATING AND AIR CONDITIONING UNITS, GRILLS, ETC. TWO COATS OF PAINT OVER ONE COAT OF PRIMER. COLOR TO MATCH ADJACENT SURFACES. D. ALL EXPOSED EDGES OF TRIM TO BE SAME COLOR AS FACE. E. NO THINNING OF MATERIAL SHALL BE ACCEPTABLE. F. SUBCONTRACTOR SHALL SEAL ALL SIX SIDES OF ALL DOORS. G. STUCCO ACCENTS PER EXTERIOR ELEVATIONS. H. THE NUMBER OF COATS NOTED ABOVE SHALL BE CONSIDERED MINIMUM. APPLY ADDITIONAL COATS IF REQUIRED TD PROVIDE FULL AND EVEN COVERAGE THROUGHOUT. I. FULLY SEAL AND PRIME ALL CUT ENDS OF WOOD MEMBERS IN CONTACT WITH OTHER WOOD MEMBERS. DIVISION 9: FINISHES, CONT. INTERIOR PAINTING AND FINISHING: A. CEILINGS AND WALLS: 1) KITCHENS, NOOKS, BATHROOMS AND INTERIOR SERVICE ROOMS, ONE COAT SEALER AND ONE COAT SEMI-GLOSS ENAMEL, UNLESS NOTED OTHERWISE. 2) ALL OTHER ROOMS: ONE COAT SEALER AND ONE COAT FLAT PAINT, UNLESS NOTED OTHERWISE. B. WARDROBES/CLOSETS: FINISH AS SPECIFIED FOR ADJOINING ROOM, EXCEPT SHELVING. C. DOORS, FRAMES, WOOD BASE, SHELF CLEATS: ONE COAT PRIMER, ONE COAT SEMI-GLOSS ENAMEL. D. STAINGRADE CABINETS: ONE COAT SANDING SEALER, ONE COAT STAIN, TWO COATS LACQUER E. STAINGRADE WOOD HAND RAILINGS, WOOD CAPS ETC.: ONE COAT STANDING SEALER. ONE COAT STAIN. TWO COATS LACQUER. F. PAINT GRADE CABINETS, RAILINGS, WOOD CAPS ETC.: ONE COAT SEALER AND ONE COAT SEMI-GLOSS ENAMEL. G. METAL SURFACES: PRIME AND PAINT SAME AS ADJACENT SURFACES. H. LUMINOUS CEILING RECESSES ARE TO BE PAINTED WITH ONE (1) COAT SEALER AND ONE (1) COAT WHITE ENAMEL HIGH GLOSS. I. ALL EXPOSED INTERIOR WOOD BEAMS TO BE PAINTED TO MATCH CEILING OR SOLID STAIN PER OWNER. J. RESAWN AND ROUGHSAWN LUMBER 1) ALL ROUGHSAWN AND RESAWN SURFACES TO RECEIVE STAIN. COLOR AND FINISH TO BE APPROVED BY BY COLOR AND MATERIAL SPECIFICATION 2) DO NOT PRIME UNLESS NOTED ON PLANS. K. THE NUMBER OF COATS NOTED ABOVE SHALL BE CONSIDERED MINIMUM. APPLY ADDITIONAL COATS IF REQUIRED TO PROVIDE FULL AND EVEN COVERAGE THROUGHOUT. DIVISION 10: SPECIALTIES SECTION 10-A GENERAL SPECIALTIES SCOPE: FURNISH AND INSTALL COMPLETE IN WORKING ORDER THE ITEMS INDICATED ON THE DRAWINGS AND AS SPECIFIED HEREIN. THE GENERAL CONTRACTOR TO VERIFY COMPATIBILITY OF ALL ADJACENT FINISH MATERIALS WITH ALL SELECTED FIXTURES AND APPLIANCES. ALL FIXTURES AND APPLIANCES TD BE CEC CERTIFIED. BATH, & PLUMBING ACCESSORIES: SEE PLANS FOR LOCATIONS WHERE OCCURS A. WATER CLOSET: 1.28 GAL AVE. WATER CONSUMPTION. AS SELECTED BY OWNER. (CPC 403.2) B. LAVATORY: AS SELECTED BY OWNER. C. TUB/SHOWER COMBINATION: AS SELECTED BY OWNER. PROVIDE WATER PROOF ENCLOSURE TO A MINIMUM 72" ABOVE THE TUB DRAIN. D. MASTER BATHTUB: AS SELECTED BY OWNER 42 INCH X 60 INCH MIN. E. SHOWER ENCLOSURE: SIZE AS INDICATED ON DRAWINGS. CERAMIC TILE SHOWER STALL OVER WATERPROOF MEMBRANE WITH FLOOR TO SLOPE TOWARDS FLOOR DRAIN WITH TEMPERED, SHATTERPROOF GLASS ENCLOSURE. CERAMIC TILE WALLS TO HEIGHT INDICATED ON INTERIOR ELEVATIONS. MINIMUM 72 INCH ABOVE DRAIN. (CPC-IAPMO STD IS-4-2003 ITEM 4.6) FRAME AS SELECTED BY OWNER. MINIMUM 72 INCH HIGH ABOVE DRAIN. F. MEDICINE CABINETS: MIRRORED DOOR, RECESS MOUNTED, TOP AT +72 INCH. G. WATER HEATER: AS SELECTED BY T-24, GAS, WITH PRESSURE/ TEMPERATURE RELIEF VALVE PIPED TD EXTERIOR OF BUILDING, WITH INSULATION BLANKET, ON MINIMUM 18 INCH HIGH PLATFORM AT GARAGE, WITH PAN AND DRAIN LINE TO OUTSIDE. FUEL BURNING EQUIPMENT TO OUTSIDE. FUEL BURNING EQUIPMENT LOCATED IN GARAGES AND SUBJECT TO MECHANICAL DAMAGE FROM THE NORMAL VEHICULAR PATH, SHALL BE PROTECTED AS INDICATED IN DRAWINGS AND AS REQUIRED BY CMC 308.1.1. ALL TANK-TYPE WATER HEATERS SHALL BE SEISMICALLY ANCHORED PER CPC SEC. 507.2 H. SHOWER HEAD: AS SELECTED BY OWNER, INSTALL MIN. 78 INCH ABOVE DRAIN. KITCHEN FIXTURES AND APPLIANCES: A. DISHWASHER: AS SELECTED BY OWNER, 24 INCH WIDE - VERIFY. B. COOKTOP: GAS. AS SELECTED BY OWNER. 30 INCH WIDE WITH 30 INCH WIDE EXHAUST HOOD, 30 INCH ABOVE COOKTOP - VERIFY. C. OVEN: GAS. AS SELECTED BY OWNER. BUILT-IN DOUBLE OVENS:30 INCH WIDE X 56 INCH HIGH - VERIFY. D. MICROWAVE OVEN: AS SELECTED BY OWNER. E. REFRIGERATOR: PROVIDE 39 INCH WIDE X 72 INCH HIGH SPACE-VERIFY F. OVEN: DOUBLE SINK AS SELECTED BY OWNER, WITH DISPOSAL: 42 INCH WIDE - VERIFY. G. GARBAGE DISPOSAL: AS SELECTED BY OWNER. FINISH HARDWARE: AS SELECTED BY OWNER. HOUSE NUMBERS: AS REQUIRED BY LOCAL AUTHORITY. MAILBOXES: AS SELECTED BY OWNER OR AS REQUIRED BY LOCAL CODE OR ORDINANCE. FIREPLACES FIREPLACES:ELEVATION AND SIZE AS DETAILED BY ARCHITECT, SEE DRAWINGS. PREFABRICATED METAL FIREBOX BY LENNOX, MERIT SERIES. ANSI Z21.50 (OR APPROVED EQUAL) WITH APPROVED SPARK ARRESTER ANY INSTALLED GAS FIREPLACE SHALL BE A DIRECT-VENT SEALED-COMBUSTION TYPE. CAL GREEN CODE SEC. 4.5D3.1 THE SPARK ARRESTOR SHALL MEET THE FOLLOWING REQUIREMENTS: (ALL CHIMNEYS ATTACHED TO ANY APPLIANCE OR FIREPLACE THAT BURNS SOLID FUEL SHALL BE EQUIPPED WITH AN APPROVED SPARK ARRESTER.) 1. THE NET FREE AREA OF THE SPARK ARRESTER SHALL NOT BE LESS THAN FOUR TIMES THE NET FREE AREA OF THE OUTLET OF THE CHIMNEY. 2. THE SPARK ARRESTER SCREEN SHALL HAVE HEAT AND CORROSION RESISTANCE EQUIVALENT TO 12 GAGE WIRE. 19 GAGE GALVANIZED WIRE OR 24 GAGE STAINLESS STEEL. 3. OPENINGS SHALL NOT PERMIT THE PASSAGE OF SPHERES HAVING A DIAMETER LARGER THAN 1/2 INCH AND SHALL NOT BLOCK THE PASSAGE OF SPHERES HAVING A DIAMETER OF LESS THAN 3/8 INCH. 4. THE SPARK ARRESTOR SHALL BE ACCESSIBLE FOR CLEANING AND THE SCREEN OR CHIMNEY CAP SHALL BE REMOVABLE TO ALLOW FOR CLEANING OF THE CHIMNEY FLUE. CRC RIOO3.9.2 DIVISION 11: EQUIPMENT SECTION 11A - APPLIANCES AND SPECIAL EQUIPMENT MEASUREMENTS: VERIFY ALL DIMENSIONS SHOWN ON THE DRAWINGS BY TAKING FIELD MEASUREMENTS; PROPER FIT AND ATTACHMENT OF ALL PARTS IS REQUIRED. NOTIFY ARCHITECT IF ANY DISCREPANCIES APPEAR. DIVISION 12: FURNISHINGS NOT INCLUDED IN THESE SPECIFICATIONS. DIVISION 13: SPECIAL CONSTRUCTION NOT INCLUDED IN THESE SPECIFICATIONS. DIVISION 14: CONVEYING EQUIPMENT NOT INCLUDED IN THESE SPECIFICATIONS. DIVISION 15: MECHANICAL SECTION 15-A HEATING SCOPE: SUPPLY ALL LABOR, TRANSPORTATION, MATERIALS, ETC., FOR INSTALLATION OF A COMPLETE HEATING AND AIR CONDITIONING SYSTEM TO OPERATE ACCORDING TO THE BEST PRACTICES OF THE TRADE INCLUDING, BUT NOT LIMITED TO: MECHANICAL UNITS, DUCTS, REGISTERS, CATWALKS, GRILLES, BOOTS, VENT PIPES, DAMPERS, COMBUSTION AIR, FANS, VENTILATORS, REFRIGERANT LINES, REFRIGERANT, ETC. ALL MATERIALS, WORK, ETC., TO COMPLY WITH ALL REQUIREMENTS OF ALL LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING JURISDICTION INCLUDING ALL COUNTY AND STATE ORDINANCES. FURNISH AND INSTALL ALL EQUIPMENT COMPLETE AND OPERABLE. VERIFY ALL MATERIAL AND INSTALLATION REQUIREMENTS AND LIMITATIONS AT FIRE AND SOUND ASSEMBLIES. * ALL DUCTS SHALL BE SEALED WITH APPROVED MASTICS, TAPES, TO PROVIDE A SUBSTANTIALLY AIRTIGHT SYSTEM. MAXIMUM DUCT LEAKAGE, BOTH SUPPLY AND RETURN, SHALL NOT EXCEED 6 PERCENT OF THE RATED CFM VOLUME PER CAL ENERGY CODE SEC. 150 INSTALLATION: A. FURNACE TO BE INSTALLED IN ATTIC AS REQUIRED BY THE CMC SEC. 904.10 B. AN ATTIC FURNACE SHALL COMPLY WITH SECTION 904.10 OF THE CMC AND THE FOLLOWING: 1.PROVIDE REQUIRED CLEARANCES FOR DUCT WORK AND TO COMBUSTIBLES. 2.PROVIDE MINIMUM 22 INCH X 30 INCH ATTIC ACCESS (BIG ENOUGH FOR LARGEST PIECE OF EQUIPMENT) OPENING AND PASSAGEWAY CONTINUOUS TO THE FURNACE AND ITS CONTROLS. (CMC 9O4.10) 3.PROVIDE AN UNOBSTRUCTED CONTINUOUS SOLID FLOOR PASSAGEWAY NOT LESS THAN 24 INCH WIDE NOT TO EXCEED 20' FROM THE ACCESS OPENING TO THE FURNACE (CMC 904.10.1 & 904.10.2) 4.PROVIDE A LEVEL WORKING PLATFORM 30 INCH DEEP (MIN. 30 INCH WIDE) IN FRONT OF THE ENTIRE FIREBOX SIDE OF THE FURNACE AND TO ALL SERVICEABLE CONTROLS, FILTERS ETC. (CMC 904.10.3) 5.PROVIDE A PERMANENT ELECTRIC OUTLET AND SWITCHED LIGHT FIXTURE AT THE ENTRANCE TO THE PASSAGEWAY. (CMC 904.10.4) C. NO ALTERATIONS TO THE STRUCTURAL FRAME, DIAPHRAGMS, CONNECTIONS OR SHEAR PANELS SHALL BE MADE WHICH WOULD COMPRISE THE DESIGNED STRUCTURAL INTEGRITY OF SUCH ELEMENTS WITHOUT PRIOR WRITTEN APPROVAL FORM THE STRUCTURAL ENGINEER. D. FUEL BURNING EQUIPMENT LOCATED IN GARAGES AND SUBJECT TO MECHANICAL DAMAGE FROM THE NORMAL VEHICULAR PATH SHALL BE PROTECTED AS INDICATED IN DRAWNGS AND AS REQUIRED BY CMC 308.1, CPC 507.13 AND NFPA 54:9.1.10.2) E. PROVIDE HIGH AND LOW COMBUSTION AIR IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS AND CMC CHAPTER 7. F. DUCTS PENETRATING WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM 0.019 INCH SHEET STEEL AND SHALL HAVE NO OPENINGS INTO THE GARAGE PER CRC SECTION R302.5.2. MATERIALS: A. DUCTS; CONSTRUCTED, INSTALLED AND INSULATED PER CHAPTER 6, CMC B. DAMPERS: PROVIDE APPROVED AUTOMATIC FIRE DAMPERS OR MINIMUM 26 GAUGE CORROSION RESISTANT METAL MATERIAL WITH SEALED EDGES AT ALL DUCTWORK PENETRATING FIRE RATED WALLS. FLOORS OR CEILINGS AS REQUIRED AND ALLOWED BY THE CMC ALL FAN SYSTEMS EXHAUSTING AIR FROM THE BUILDING ENVELOPE TO THE OUTSIDE SHALL BE PROTECTED WITH BACKDRAFT DAMPERS. FIRE DAMPERS SHALL BE INSTALLED IN ACCORDANCE W/ THEIR LISTING. CALCULATIONS AND DRAWINGS: CONTRACTOR TO SUPPLY AND SUBMIT TO THE BUILDING DEPARTMENT, CALCULATIONS AND DRAWINGS FOR APPROVAL. SUBMIT ONE (1) SET TO THE ARCHITECT FOR REVIEW FOR CONFORMANCE WITH THE USUAL DESIGN CONCEPT PRIOR TO COMMENCING WORK. EQUIPMENT SHALL COMPLY WITH STATE ENERGY REQUIREMENTS FOR EFFICIENCY DUCT WORK "R" VALUE SHALL ALSO COMPLY WITH STATE ENERGY REQUIREMENTS. SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO A0.3 GENERAL NOTES AND SPECIFICATIONS DIVISION 15: MECHANICAL, CONT. SECTION 15-B PLUMBING SCOPE: SUPPLY ALL LABOR, TRANSPORTATION, MATERIALS, ETC., FOR INSTALLATION OF COMPLETE PLUMBING SYSTEM TO OPERATE ACCORDING TO THE BEST PRACTICES OF THE TRADE AND INCLUDING, BUT NOT LIMITED TO FIXTURES, HOT AND COLD WATER PIPING, EXHAUST FLUES, COMBUSTION AIR, GAS PIPING, LOG LIGHTERS, DRAINS, SOIL AND VENT PIPING, HOT WATER HEATERS, PIPE INSULATION, METERS, VALVES, VAULTS, ETC. ALL MATERIALS, WORK, ETC, TO COMPLY WITH ALL REQUIREMENTS OF ALL LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING JURISDICTION INCLUDING ALL COUNTY AND STATE ORDINANCES. FURNISH AND INSTALL PLUMBING WORK COMPLETE AND OPERABLE, INCLUDING TRENCHING AND BACKFILLING. VERIFY ALL MATERIAL AND INSTALLATION REQUIREMENTS AND LIMITATIONS AT FIRE AND SOUND ASSEMBLIES. INSTALLATION: A. ROUGHING-IN SHALL BE COMPLETED, TESTED AND INSPECTED AS REQUIRED BY CODE BEFORE CLOSING-IN WITH OTHER WORK. B. OPENINGS IN PIPES, DRAINS, AND FITTINGS SHALL BE KEPT COVERED DURING CONSTRUCTION. C. PROVIDE SOLID BACKING FOR SECURING FIXTURES. ALL FIXTURES TO BE SET LEVEL. D. PROVIDE CLEANOUTS AT ENDS OF ALL LINES AND WHERE REQUIRED BY CODES. E. COPPER TUBING SHALL BE FULLY SWEATED TO FITTINGS. ALL COPPER PIPE CONNECTIONS TO FERROUS PIPING SHALL BE MADE WITH DIELECTRIC COUPLING OR ISOLATION FLANGES. F. BLACK IRON AND GALVANIZED STEEL PIPE JOINTS SHALL BE MADE WITH APPROVED PIPE THREAD COMPOUND. G. PROVIDE SHUT-OFF VALVES AT EACH FIXTURE. H. PROVIDE CONDENSATE LINE AT EACH F.A.U. LOCATION. PROVIDE PRIMARY & SECONDARY CONDENSATE LINE TO AN APPROVED DRAINAGE RECEPTACLE AT ATTIC F.A.U. LOCATIONS. I. PROVIDE COLD WATER LINE TO REFRIGERATOR SPACE IN RECESSED BOX OR IN CABINET IMMEDIATELY ADJACENT TO REFRIGERATOR SPACE. J. ALL VENTS TO LEAD TO OUTSIDE AIR, WHERE POSSIBLE, LOCATE ALL ROOF VENTS TO REAR SIDE OR RIDGES. K. ALL HORIZONTAL A.B.S PIPING SHALL BE HUNG WITH APPROVED HANGERS AT 4'-0" ON CENTER MAXIMUM AND SPACED TO PERMIT EXPANSION AND CONTRACTION WITHOUT HITTING ADJOINING PIPE. VERTICAL PIPING SHALL BE SUPPORTED AT 8'-0” ON CENTER WITH WROUGHT STEEL "U' STRAPS SECURELY FASTENED TO BUILDING FRAME. ALTERNATE METHODS MUST BE DESCRIBED BY CODE AND APPROVED BY BUILDER / STRUCTURAL ENGINEER. L. PROVIDE AIR CHAMBERS AT LAVATORY, DISHWASHER AND CLOTHES WASHER WATER CONNECTIONS. SET VERTICALLY AS CLOSE TO THE FIXTURE AS FEASIBLE. M. PROVIDE 3/4 INCH TEE FOR IRRIGATION AT MAIN SHUT-OFF. N. PROVIDE WATER HEATER SEISMIC RESTRAINTS AS REQUIRED BY LOCAL CODE. O. NO ALTERATIONS TO THE STRUCTURAL FRAME, DIAPHRAGMS, CONNECTIONS OR SHEAR PANELS SHALL BE MADE WHICH WOULD COMPROMISE THE DESIGNED STRUCTURAL INTEGRITY OF SUCH ELEMENTS WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER. MATERIALS: A. CORROSIVE PROPERTIES OF SOIL: FOLLOW ALL RECOMMENDATIONS IN THE FINAL SOILS REPORT (IF REQUIRED) OR LOCAL DESIGN MINIMUMS FOR ALL MATERIALS PLACED WITHIN OR IN PROXIMITY OF SOIL AS NECESSARY. B. CLEANOUTS: OWNER SELECTED SUBSTITUTE. C. DOMESTIC WATER PIPING: TYPE "L' OR 'K" COPPER TUBING BELOW GRADE AND SLAB - VERIFY WITH SOIL COMPATIBILITY; ALL OTHER COPPER TUBING SHALL BE TYPE V. FITTINGS -WROUGHT COPPER OR CAST BRONZE. USE NO-LEAD SOLDER. D. DIELECTRIC INSULATORS: EPCA TYPE "FX", "FB" OR "GX" DIELECTRIC UNIONS. E. VENT PIPING: ABS D2661-68. F. VALVES, STOPS, CLOCKS: OWNER SELECTED SUBSTITUTE. G. ROOF FLASHINGS: SEE SECTION 7B. H. FIXTURES AND FITTINGS: SEE SECTION 10. I. PROVIDE RECESSED FAUCET BOX AT WASHER. J. DRAINS: SIZED AS REQUIRED. PROVIDE OVERFLOWS AS INDICATED ON DRAWINGS AND AS NECESSARY. K. AIR CHAMBERS AT EACH END OF HEADERS, SHALL BE 36 INCH LONG, ONE PIPE SIZE LARGER THAN HEADER. INDIVIDUAL CHAMBERS SHALL BE 18 INCH LONG, ONE PIPE SIZE LARGER THAN BRANCH TO FIXTURE. ALTERNATE METHODS MUST BE DESCRIBED BY CODE AND APPROVED BY THE BUILDING OFFICIAL. L. WATER HEATERS SHALL CONFORM TD STATE ENERGY REGULATIONS AND SHALL BE CEC LISTED. M. WATER HEATERS OVER 4' FEET HIGH WITH NON-RIGID WATER CONNECTIONS SHALL BE SECURED TO RESIST EARTHQUAKES, PER CMC REQUIREMENTS. DIVISION 16: ELECTRICAL CALCULATIONS AND DRAWINGS: CONTRACTOR TO SUPPLY AND SUBMIT TO THE BUILDING DEPARTMENT LOAD CALCULATIONS AND DRAWINGS FOR APPROVAL PRIOR TO COMMENCING WORK. SUBMIT ONE (1) SET TO THE ARCHITECT FOR REVIEW FOR CONFORMANCE WITH THE VISUAL DESIGN CONCEPT PRIOR TO COMMENCING WORK. METERS: VERIFY ALL REQUIREMENTS WITH GOVERNING UTILITY COMPANY. SECTION 16-A ELECTRICAL CALCULATIONS AND DRAWINGS: CONTRACTOR TO SUPPLY AND SUBMIT TO THE BUILDING DEPARTMENT LOAD CALCULATIONS AND DRAWINGS FOR APPROVAL PRIOR TO COMMENCING WORK. SUBMIT ONE (1) SET TO THE ARCHITECT FOR REVIEW FOR CONFORMANCE WITH THE VISUAL DESIGN CONCEPT PRIOR TO COMMENCING WORK. METERS, VERIFY ALL REQUIREMENTS WITH GOVERNING UTILITY COMPANY. SECTION 16-A ELECTRICAL ARCHITECTS ELECTRICAL SYSTEM LAYOUTS ARE GENERALLY A DIAGRAMMATIC LOCATION OF OUTLETS AND EQUIPMENT IS APPROXIMATE ACTUAL ROUTING OF WIRING. NOTIFY ARCHITECT IF PROPOSED LOCATIONS OF OUTLETS AND LIGHT FIXTURES ARE IN CONFLICT WITH STRUCTURAL CONDITIONS AND EXISTING CONSTRUCTION. WIRING FOR EQUIPMENT REQUIRING MAINTENANCE AND INSPECTION TO BE READILY ACCESSIBLE. METERS, SUPPLY ALL LABOR, TRANSPORTATION, MATERIALS, ETC . FOR INSTALLATION OF COMPLETE ELECTRICAL SYSTEM TD OPERATE ACCORDING TO THE BEST PRACTICES OF THE TRADE AND INCLUDING. BUT NOT LIMITED TO FIXTURES, APPLIANCES, WIRING, SWITCHES, OUTLETS, TELEVISION JACKS, SERVICES, GROUNDS, TEMPORARY POWER, JUNCTION BOXES, CONDUIT, SUBPANELS, ETC. ALL WORK, MATERIALS, ETC. TO COMPLY WILL, ALL REQUIREMENTS OF ALL LEGALLY CONSTITUTED AUTHORITIES HAVING JURISDICTION INCLUDING ALL COUNTY AND STATE ORDINANCES. FURNISH AND INSTALL ELECTRICAL WORK COMPLETE AND OPERABLE. VERIFY ALL MATERIAL AND INSTALLATION REQUIREMENTS AND LIMITATIONS AT FIRE AND SOUND ASSEMBLIES. STANDARDS: ELECTRICAL SERVICES: UNDERGROUND. THE SERVING UTILITY WILL PROVIDE AND INSTALL ALL PRIMARY AND SECONDARY SERVICE RACEWAYS AND CONDUCTORS INCLUDING TRANSFORMER PADS AND CONNECTIONS TO THE LINE SIDE OF ALL BUILDING MAIN DISCONNECTS. RACEWAYS, SIZED AS DESIGNATED BY THE SERVICE UTILITY, SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR FROM EACH BUILDING MAIN DISCONNECT TO THE EXTERIOR BUILDING LINE FOR CONTINUATION BY THE SERVICING UTILITY. WORK AND EQUIPMENT SHALL BE IN ACCORDANCE WITH THE BEST PRACTICES OF THE TRADE AND CONFORM TO ALL LOCAL GOVERNING AGENCIES. MATERIALS AND EQUIPMENT SHALL BE UL APPROVED. CORROSIVE PROPERTIES OF SOIL: FOLLOW ALL RECOMMENDATIONS IN THE FINAL SOILS REPORT IF REQUIRED, OR LOCAL DESIGN CRITERIA, FOR ALL MATERIALS PLACED WITHIN OR IN PROXIMITY OF SOIL AS NECESSARY. SHOULD A CONFLICT ARISE BETWEEN THIS SPECIFICATION, THE DRAWINGS OR ANOTHER ELECTRICAL SPECIFICATION ISSUED AS A PART OF THESE DOCUMENTS, THE MORE STRINGENT SHALL PREVAIL. INSTALLATION: A. PROVIDE SEPARATE CIRCUITS EACH FOR DISHWASHER, GARBAGE DISPOSAL REFRIGERATOR, WASHER, DRYER, F.A.U. AND MICROWAVE OVEN. B. SWITCHED OUTLETS SHALL BE 1/2 HOT. C. BATHROOM FANS: WHERE PERMITTED BY CODE, SWITCH FANS SEPARATELY FROM LIGHT. PROVIDE EXHAUST FANS AT TOILET ROOMS AND/OR AREAS WITH TUBS, SHOWERS OR SPAS WITH A MIN 50 CFM FAN. (CMC TABLE 403.7). ALL EXHAUST VENTS TO LEAD TD OUTSIDE AIR AND BE 3'-0" MIN. FROM ANY OPENINGS OR PROPERTY LINES. (CMC 504.5) D. ALL EQUIPMENT INSTALLED OUTDOORS AND EXPOSED TO WEATHER SHALL BE WEATHERPROOF. E. PROVIDE GROUND FAULT CIRCUIT INTERRUPTERS, G.F.I. PROTECTION IN BATHROOMS, GARAGES, OUTDOORS, IN KITCHENS WHERE RECEPTACLES ARE INSTALLED TO SERVE COUNTERTOP SURFACES, AND WITHIN 6 FT OF OUTSIDE EDGE OF A WET BAR SINK WHERE RECEPTACLES ARE INSTALLED TO SERVE COUNTERTOP SURFACES. <ART. 550.13.B F. PROVIDE LOW VOLTAGE STUB OUT FOR HOUSE NUMBERS IF LOCAL CODE REQUIRES ILLUMINATION. G. KITCHEN AND BATHROOM LIGHTING SHALL BE IN ACCORDANCE WITH STATE ENERGY MANDATORY REQUIREMENTS. H. EACH CONDUCTOR OF EVERY SYSTEM SHALL BE PERMANENTLY TAGGED IN COMPLIANCE WITH O.S.H.A. I. ALL CONDUIT SHALL BE INSTALLED CONCEALED WHERE PHYSICALLY POSSIBLE. ALL EXPOSED CONDUIT SHALL BE INTERMEDIATE METAL CONDUIT OR E.M.T. AND INSTALLED PARALLEL TO DR AT RIGHT ANGLES WITH THE BUILDING WALLS. IF VIEWED BY THE PUBLIC, PAINT TO MATCH SURFACE TO WHICH IT IS ATTACHED. J. THE COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH PRESENTLY ADOPTED EDITION OF THE CEC , PARTS V, VI AND VII OF ARTICLE #250 K. PENETRATIONS TO FIRE-RATED MATERIALS SHALL BE RESTORED TO EQUAL RATING AS REQUIRED BY LOCAL ENFORCING AGENCY. FLAME SEAL AS MANUFACTURED BY NELSON ELECTRIC OR APPROVED EQUAL. ALL ELECTRICAL SYSTEM CONDUCTORS SHALL BE INSTALLED IN APPROVED RACEWAYS. NON-METALLIC, SHEATHED CABLE "ROMEX' IS NOT APPROVED FOR PENETRATIONS OF FIRE RATED ASSEMBLIES. L. USE ONLY COMPETENT AND SKILLED PERSONNEL AND PERFORM ALL WORK, INCLUDING AESTHETIC AS WELL AS ELECTRICAL AND MECHANICAL ASPECTS TO STANDARDS CONSISTENT WITH THE BEST PRACTICES OF THE TRADE. M. ALL CONDUIT ONLY INSTALLATIONS SHALL HAVE A PULL WIRE OR ROPE. N. NO ALTERATIONS TO THE STRUCTURAL FRAME, DIAPHRAGMS, CONNECTIONS OR SHEAR PANELS SHALL BE MADE WHICH WOULD COMPROMISE THE DESIGNED STRUCTURAL INTEGRITY OF SUCH ELEMENTS WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER. DIVISION 16: ELECTRICAL, CONT. INSTALLATION HEIGHTS: ALL HEIGHTS GIVEN ARE TO BOTTOM OF FIXTURE OR OUTLET. A. EXTERIOR LIGHT FIXTURES TO BE +72 INCH FROM FINISH FLOOR UNLESS NOTED OTHERWISE. B. TYPICAL WALL OUTLETS TO BE +12 INCH FROM FINISH FLOOR. C. TYPICAL WALL SWITCHES TO BE +36 INCH FROM FINISH FLOOR. D. ABOVE-COUNTER OUTLETS AT KITCHEN TO BE +44 INCH FROM FINISH FLOOR. E. ABOVE-COUNTER OUTLETS AT BATHS TO BE +38 INCH FROM FINISH FLOOR. F. WALL OUTLET FOR RANGE HOOD TO BE +78 INCH FROM FINISH FLOOR. G. SMOKE DETECTORS LOCATED PER CODE REQUIREMENTS. H. DOOR CHIMES LOCATED WITHIN 12 INCH OF CEILING. I. PUSH BUTTONS TO BE +36 INCH FROM FINISH FLOOR. J. ABOVE-COUNTER OUTLETS AT LINEN OR OTHER MISCELLANEOUS COUNTERS TO BE +44 INCH FROM FINISH FLOOR. K. OUTLETS AT SERVICE AREAS TO BE +48 INCH FROM FINISH FLOOR. L. THERMOSTATS TO BE AT +60 INCH FROM FINISH FLOOR. M. WALL OUTLET FOR MICROWAVE/RANGE HOOD TO BE +78 INCH FROM FINISH FLOOR, WHEN THEY OCCUR. N. LIGHT BARS IN BATHROOMS TO BE +84 INCH FROM FINISH FLOOR, WHEN THEY OCCUR. O. STEP LIGHTS TO BE +6 INCH ABOVE SKIRT BOARD, WHEN THEY OCCUR. P. REFER TO LANDSCAPE DRAWINGS IF AVAILABLE FOR ALL COMMON AREA WALLS AND EXTERIOR LIGHTING SURROUNDING BUILDING NOT INDICATED. VERIFY AND LOCATE: ALL OUTLETS PRIOR TO INSTALLATION OF GYPSUM WALLBOARD. LOCATE ALL SWITCHES AND FIXTURES FROM FINISHED FLOOR PER ELECTRICAL PLANS AND NOTES. MATERIALS: A. SWITCHES: SILENT TYPE B. INTERIOR OUTLETS: DUPLEX TYPE, 15A, 125 VOLT C. EXTERIOR OUTLETS: SINGLE WEATHERPROOF TYPE, G.F.I. D. OUTLETS AND PULL BOXES: GALVANIZED OR SHERARDIZED. E. PANEL BOXES: CIRCUIT BREAKER TYPE, RECESSED FLUSH MOUNTED, GALVANIZED AND PRIME COATED WITH LATCH. PROVIDE TYPEWRITTEN CARD IDENTIFYING CIRCUITS. F. CONDUIT, CABLE, WIRE: PER PRESENTLY ADOPTED EDITION OF THE C.E.C. G. FLUORESCENT TUBES AND BULBS: FULL SPECTRUM 3500K. H. RECESSED INCANDESCENT LIGHT FIXTURES: IN THE PROXIMITY OF ATTIC, CEILING OR FLOOR INSULATION SHALL BE I.C. TYPE. I. ALL MATERIALS SHALL BE NEW AND OF THE SAME MANUFACTURER FOR EACH CLASS OR GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED AND APPROVED BY UNDERWRITER'S LABORATORIES AND SHALL BEAR THE INSPECTION LABEL WHERE SUBJECT TO SUCH APPROVAL. MATERIALS SHALL MEET WITH THE APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY AND ALL GOVERNING BODIES HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS ESTABLISHED BY ANSI, U.L, N.E.M.A. AND N.B.F.U. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. J. CONDUCTORS SHALL BE CODE GRADE, 600 VOLT CLASS, COPPER, MARKED 24 INCH ALONG IT'S LENGTH, SHOWING MANUFACTURER'S NAME, MAXIMUM ALLOWABLE VOLTAGE AND SIZE CONDUCTORS SHALL BE TYPE “THWN” - WET. DELIVER THE WIRE TO THE SITE IN UNBROKEN PACKAGES. K. IF ALUMINUM FEEDER CONDUCTORS ARE APPROVED FOR SUBSTITUTION, COPPER ONLY WITHIN UNITS, AND INSTALLED, FINAL CONNECTIONS TO VIBRATING EQUIPMENT SHALL BE COPPER ONLY AND ALL ALUMINUM TERMINATIONS SHALL BE MADE USING A "HYPRESS" IDOL OR OTHER MANUFACTURER'S RECOMMENDATIONS. PROVIDE ANTI-OXIDE COMPOUND ON ALL ALUMINUM TERMINATIONS. NO ALUMINUM CONDUCTOR SMALLER THAN #4 AWG. HOUSE SERVICE: SIZE PER REQUIREMENTS, MINIMUM 2DOA, 1 INCH DIA., 3 W SERVICE. COLORS AND DESIGN: A. SWITCH PLATES, COVERS, ETC.: AS SELECTED BY OWNER. B. FIXTURES: AS SELECTED BY OWNER. FIRE WARNING SYSTEM: SMOKE DETECTORS AND ALARM SYSTEM SHALL BE HARD-WIRED WITH BATTERY BACK-UP POWER AND LOW BATTERY SIGNAL AND INSTALLED AS REQUIRED BY CRC. SEC. R314.4 DETECTORS SHALL BE PLACED IN CORRIDORS, ADJACENT ROOMS AND SLEEPING ROOMS - PER MANUFACTURER'S RECOMMENDATIONS. DETECTORS SHALL BE PLACED IN CLOSE PROXIMITY TO STAIRWAY WHEN BEDROOMS ARE LOCATED ON UPPER FLOOR. ALL DETECTORS SHALL BE INTERCONNECTED TO SOUND A SIMULTANEOUS ALARM -AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING UNIT. CRC SEC. R314.3 METERS: VERIFY ALL REQUIREMENTS WITH GOVERNING UTILITY COMPANY. ELECTRICAL PLANS AND CALCULATIONS: SHALL BE DRAWN AND SUBMITTED BY THE ELECTRICAL SUBCONTRACTOR TO THE BUILDING DEPARTMENT FOR APPROVAL SUBMIT ONE (1) SET TO THE ARCHITECT FOR REVIEW FOR CONFORMANCE WITH THE VISUAL DESIGN CONCEPT. ELECTRICAL SUBCONTRACTOR SHALL COORDINATE DRAWINGS WITH THE ARCHITECT. SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 PLANNING AND DESIGN DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING. Annular spaces around pipes, electric cables, conduits or other openings in sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency. 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65 percent of the non-hazardous construction and demolition waste in accordance with either Section 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste management ordinance. Exceptions: 1. Excavated soil and land-clearing debris. 2. Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist or are not located reasonably close to the jobsite. 3. The enforcing agency may make exceptions to the requirements of this section when isolated jobsites are located in areas beyond the haul boundaries of the diversion facility. 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN. Submit a construction waste management plan in conformance with Items 1 through 5. The construction waste management plan shall be updated as necessary and shall be available during construction for examination by the enforcing agency. 1. Identify the construction and demolition waste materials to be diverted from disposal by recycling, reuse on the project or salvage for future use or sale. 2. Specify if construction and demolition waste materials will be sorted on-site (source separated) or bulk mixed (single stream). 3. Identify diversion facilities where the construction and demolition waste material collected will be taken. 4. Identify construction methods employed to reduce the amount of construction and demolition waste generated. 5. Specify that the amount of construction and demolition waste materials diverted shall be calculated by weight or volume, but not by both. 4.408.3 WASTE MANAGEMENT COMPANY. Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with Section 4.408.1. Note: The owner or contractor may make the determination if the construction and demolition waste materials will be diverted by a waste management company. 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 3.4 lbs./sq.ft. of the building area shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 2 pounds per square foot of the building area, shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.5 DOCUMENTATION. Documentation shall be provided to the enforcing agency which demonstrates compliance with Section 4.408.2, items 1 through 5, Section 4.408.3 or Section 4.408.4.. Notes: 1. Sample forms found in "A Guide to the California Green Building Standards Code (Residential)" located at www.hcd.ca.gov/CALGreen.html may be used to assist in documenting compliance with this section. 2. Mixed construction and demolition debris (C & D) processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 4.410 BUILDING MAINTENANCE AND OPERATION 4.410.1 OPERATION AND MAINTENANCE MANUAL. At the time of final inspection, a manual, compact disc, web-based reference or other media acceptable to the enforcing agency which includes all of the following shall be placed in the building: 1. Directions to the owner or occupant that the manual shall remain with the building throughout the life cycle of the structure. 2. Operation and maintenance instructions for the following: a. Equipment and appliances, including water-saving devices and systems, HVAC systems, photovoltaic systems, electric vehicle chargers, water-heating systems and other major appliances and equipment. b. Roof and yard drainage, including gutters and downspouts. c. Space conditioning systems, including condensers and air filters. d. Landscape irrigation systems. e. Water reuse systems. 3. Information from local utility, water and waste recovery providers on methods to further reduce resource consumption, including recycle programs and locations. 4. Public transportation and/or carpool options available in the area. 5. Educational material on the positive impacts of an interior relative humidity between 30-60 percent and what methods an occupant may use to maintain the relative humidity level in that range. 6. Information about water-conserving landscape and irrigation design and controllers which conserve water. 7. Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 feet away from the foundation. 8. Information on required routine maintenance measures, including, but not limited to, caulking, painting, grading around the building, etc. 9. Information about state solar energy and incentive programs available. 10. A copy of all special inspections verifications required by the enforcing agency or this code. 11. Information from the Department of Forestry and Fire Protection on maintenance of defensible space around residential structures. 12. Information and/or drawings identifying the location of grab bar reinforcements. 4.410.2 RECYCLING BY OCCUPANTS. Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible area(s) that serves all buildings on the site and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waster, and metals, or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A) et seq. are note required to comply with the organic waste portion of this section. DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY DIVISION 4.5 ENVIRONMENTAL QUALITY 4.303 INDOOR WATER USE 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the sections 4.303.1.1, 4.303.1.2, 4.303.1.3, and 4.303.4.4. Note: All noncompliant plumbing fixtures in any residential real property shall be replaced with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy, or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 4.303.1.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-type Toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 4.303.1.2 Urinals. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush. The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush. 4.303.1.3 Showerheads. 4.303.1.3.1 Single Showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to only allow one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. 4.303.1.4 Faucets. 4.303.1.4.1 Residential Lavatory Faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. 4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. 4.303.1.4.3 Metering Faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.2 gallons per cycle. 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.1.4.5 Pre-rinse spray valves. When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Sections 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7) and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY: The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations),Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). Title 20 Section 1605.3 (h)(4)(A): Commercial prerinse spray values manufactured on or after January 1, 2006, shall have a minimum spray force of not less than 4.0 ounces-force (ozf)[113 grams-force(gf)] 4.303.2 Submeters for multifamily buildings and dwelling units in mixed-used residential/commercial buildings. Submeters shall be installed to measure water usage of individual rental dwelling units in accordance with the California Plumbing Code. 4.303.3 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code. TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL) 1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL) MAX. 1.2 GPM @ 60 PSI MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.2 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH 4.304 OUTDOOR WATER USE 4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Residential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. NOTES: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code Regulations, Title 23, Chapter 2.7, Division 2. MWELO and supporting documents, including water budget calculator, are available at: https://www.water.ca.gov/ ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New NOTE: THIS TABLE COMPILES THE DATA IN SECTION 4.303.1, AND IS INCLUDED AS A CONVENIENCE FOR THE USER. SECTION 4.102 DEFINITIONS 4.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) FRENCH DRAIN. A trench, hole or other depressed area loosely filled with rock, gravel, fragments of brick or similar pervious material used to collect or channel drainage or runoff water. WATTLES. Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also used for perimeter and inlet controls. 4.106 SITE DEVELOPMENT 4.106.1 GENERAL. Preservation and use of available natural resources shall be accomplished through evaluation and careful planning to minimize negative effects on the site and adjacent areas. Preservation of slopes, management of storm water drainage and erosion controls shall comply with this section. 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. Projects which disturb less than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more, shall manage storm water drainage during construction. In order to manage storm water drainage during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site. 1. Retention basins of sufficient size shall be utilized to retain storm water on the site. 2. Where storm water is conveyed to a public drainage system, collection point, gutter or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the enforcing agency. 3. Compliance with a lawfully enacted storm water management ordinance. Note: Refer to the State Water Resources Control Board for projects which disturb one acre or more of soil, or are part of a larger common plan of development which in total disturbs one acre or more of soil. (Website: https://www.waterboards.ca.gov/water_issues/programs/stormwater/construction.html) 4.106.3 GRADING AND PAVING. Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1. Swales 2. Water collection and disposal systems 3. French drains 4. Water retention gardens 5. Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 4.106.4 Electric vehicle (EV) charging for new construction. New construction shall comply with Section 4.106.4.1 or 4.106.4.2. Electric vehicle supply equipment (EVSE) shall comply with the California Electrical Code. Exceptions: 1. On a case-by-case basis, where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon one or more of the following conditions: 1.1 Where there is no local utility power supply or the local utility is unable to supply adequate power. 1.2 Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 4.106.4, may adversely impact the construction cost of the project. 2. Accessory Dwelling Units (ADU) and Junior Accessory Dwelling Units (JADU) without additional parking facilities. 4.106.4.1 New one- and two-family dwellings and townhouses with attached private garages. For each dwelling unit, install a listed raceway to accommodate a dedicated 208/240-volt branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40-ampere 208/240-volt minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. Exemption: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the proposed location of an EV charger at the time of original construction in accordance with the California Electrical Code. 4.106.4.1.1 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration. The mandatory provision of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings. See Section 4.106.4.3 for application. Note: Repairs including, but not limited to, resurfacing, restriping and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section. Note: On and after January 1, 2014, residential buildings undergoing permitted alterations, additions, or improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] The provisions of individual sections of CALGreen may apply to either low-rise residential buildings high-rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and high-rise buildings, no banner will be used. SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. Exceptions: 1. [HCD] Accessory structures and accessory occupancies serving residential buildings shall comply with Chapter 4 and Appendix A4, as applicable. 2. [HCD] For purposes of CALGreen, live/work units, complying with Section 419 of the California Building Code, shall not be considered mixed occupancies. Live/Work units shall comply with Chapter 4 and Appendix A4, as applicable. 4.106.4.2 New multifamily dwellings, hotels and motels and new residential parking facilities. When parking is provided, parking spaces for new multifamily dwellings, hotels and motels shall meet the requirements of Section 4.106.4.2.2. Calculations for spaces shall be rounded up to the nearest whole number. A parking space served by electric vehicle supply equipment or designed as an EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by a local jurisdiction. See Vehicle Code Section 22511.2 for further details. 4.106.4.2.1 Reserved. 4.106.4.2.2 Multifamily dwellings, hotels and motels 1. EV ready parking spaces with receptacles. a. Hotels and motels. Forty (40) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. b. Multifamily parking facilities. Forty (40) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. EV charging receptacles required by this section shall be located in at least one assigned parking space per dwelling unit where assigned parking is provided but need not exceed forty (40) percent of the total number of assigned parking spaces provided on the site. Exception: Areas of parking facilities served by parking lifts, including but not limited to automated mechanical-access open parking garages as defined in the California Building Code; or parking facilities otherwise incapable of supporting electric vehicle charging. c. Receptacle power source. EV charging receptacles in multifamily parking facilities shall be provided with a dedicated branch circuit connected to the dwelling unit’s electrical panel, unless determined as infeasible by the project builder or designer and subject to concurrence of the local enforcing agency. Exception: Areas of parking facilities served by parking lifts, including but not limited to automated mechanical-access open parking garages as defined in the California Building Code; or parking facilities otherwise incapable of supporting electric vehicle charging. d. Receptacle configurations. 208/240V EV charging receptacles shall comply with one of the following configurations: 1. For 20-ampere receptacles, NEMA 6-20R 2. For 30-ampere receptacles, NEMA 14-30R 3. For 50-ampere receptacles, NEMA 14-50R 2. EV ready parking spaces with EV chargers. a. Hotels and motels. Ten (10) percent of the total number of parking spaces shall be equipped with Level 2 EV chargers. At least fifty (50) percent of the required EV chargers shall be equipped with J1772 connectors. b. Multifamily parking facilities. Ten (10) percent of the total number of parking spaces shall be equipped with Level 2 EV chargers. At least fifty (50) percent of the required EV chargers shall be equipped with J1772 connectors. Where common use parking or unassigned parking is provided, EV chargers shall be located in common use or unassigned parking areas and shall be available for use by all residents or guests. Where low power Level 2 EV charging receptacles or Level 2 EV chargers are installed beyond the minimum required, an automatic load management system (ALMS) may be used to reduce the maximum required electrical capacity to each space served by the ALMS. The electrical system and any on-site distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40 amperes, and installed EV chargers shall have a capacity of not less than 30 amperes. 4.106.4.2.2.1 Electric vehicle charging stations (EVCS). Electric vehicle charging stations required by Section 4.106.4.2.2, Item 2, with EV chargers installed shall comply with Section 4.106.4.2.2.1.1. Exception: Electric vehicle charging stations serving public accommodations, public housing, motels and hotels shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable requirements. 4.106.4.2.2.1.1 Electric vehicle charging stations (EVCS) spaces with EV chargers installed; dimensions and location. EVCS spaces shall be designed to comply with the following: 1. The minimum length of each EVCS space shall be 18 feet (5486 mm). 2. The minimum width of each EVCS space shall be 9 feet (2743 mm). 3. One in every 25 EVCS spaces, but not less than one, shall also have an 8-foot (2438 mm) wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the EVCS space is 12 feet (3658 mm). Surface slope for this EVCS space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope) in any direction. These EVCS spaces shall also comply with at least one of the following: a. The EVCS space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space. b. The EVCS space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building. Exception: Electric vehicle charging stations designed and constructed in compliance with the California Building Code, Chapter 11B, are not required to comply with Section 4.106.4.2.2.1.1. 4.106.4.2.2.1.2 Accessible electric vehicle charging station spaces. In addition to the requirements in Section 4.106.4.2.2.1.1, all EV chargers, where installed, shall comply with the accessibility provisions for EV chargers in the California Building Code, Chapter 11B. EV ready spaces and EVCS in multifamily developments shall comply with California Building Code, Chapter 11A, Section 1109A. 4.106.4.2.3 Reserved. 4.106.4.2.4 Reserved. 4.106.4.2.5 Electric vehicle ready space signage. Electric vehicle ready spaces shall be identified by signage or pavement markings, in compliance with Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 4.106.4.3 Electric vehicle charging for additions and alterations of parking facilities serving existing multi-family buildings. Where new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten (10) percent of the total number of parking spaces added or altered shall be EV capable spaces to support future Level 2 electric vehicle supply equipment. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE.” Notes: 1.Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. 2.There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use. SECTION 4.501 GENERAL 4.501.1 Scope The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous, irritating and/or harmful to the comfort and well being of a building's installers, occupants and neighbors. SECTION 4.502 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) AGRIFIBER PRODUCTS. Agrifiber products include wheatboard, strawboard, panel substrates and door cores, not including furniture, fixtures and equipment (FF&E) not considered base building elements. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. "Composite wood products" does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated wood I-joists or finger-jointed lumber, all as specified in California Code of regulations (CCR), title 17, Section 93120.1. DIRECT-VENT APPLIANCE. A fuel-burning appliance with a sealed combustion system that draws all air for combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AY N/AY N/AY N/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 1 (July 2024 Supplement)Y = YES N/A = NOT APPLICABLE RESPON. PARTY = RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) 4.201 GENERAL 4.201.1 SCOPE. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards. DIVISION 4.2 ENERGY EFFICIENCY TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤5.0ozf︶1.00 Product Class 2 (> 5.0 ozf and ≤8.0ozf︶1.20 Product Class 3 (> 8.0 ozf)1.28 SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DESIGNER ELIZABETH CAO 01-13-2026 DD NGUYEN RESIDENCE 2314 W SAN LORENZO SANTA ANA, CA 92704 A0.4 CAL GREEN STANDARDS 3 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 3 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N 05 - 0 8 - 2 6 B U I L D I N G C O R R E C T I O N DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base Reactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundredths of a gram (g O³/g ROC). Note: MIR values for individual compounds and hydrocarbon solvents are specified in CCR, Title 17, Sections 94700 and 94701. MOISTURE CONTENT. The weight of the water in wood expressed in percentage of the weight of the oven-dry wood. PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging). Note: PWMIR is calculated according to equations found in CCR, Title 17, Section 94521 (a). REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. VOC. A volatile organic compound (VOC) broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a). 4.503 FIREPLACES 4.503.1 GENERAL. Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. 4.504 POLLUTANT CONTROL 4.504.1 COVERING OF DUCT OPENINGS & PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. At the time of rough installation, during storage on the construction site and until final startup of the heating, cooling and ventilating equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheet metal or other methods acceptable to the enforcing agency to reduce the amount of water, dust or debris which may enter the system. 4.504.2 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with this section. 4.504.2.1 Adhesives, Sealants and Caulks. Adhesives, sealant and caulks used on the project shall meet the requirements of the following standards unless more stringent local or regional air pollution or air quality management district rules apply: 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable or SCAQMD Rule 1168 VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and tricloroethylene), except for aerosol products, as specified in Subsection 2 below. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than 1 pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with section 94507. 4.504.2.2 Paints and Coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 4.504.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources Board, Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 4.504.3 shall apply. 4.504.2.3 Aerosol Paints and Coatings. Aerosol paints and coatings shall meet the Product-weighted MIR Limits for ROC in Section 94522(a)(2) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(e)(1) and (f)(1) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8, Rule 49. 4.504.2.4 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following: 1. Manufacturer's product specification. 2. Field verification of on-site product containers. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3. Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. 4.505 INTERIOR MOISTURE CONTROL 4.505.1 General. Buildings shall meet or exceed the provisions of the California Building Standards Code. 4.505.2 CONCRETE SLAB FOUNDATIONS. Concrete slab foundations required to have a vapor retarder by California Building Code, Chapter 19, or concrete slab-on-ground floors required to have a vapor retarder by the California Residential Code, Chapter 5, shall also comply with this section. 4.505.2.1 Capillary break. A capillary break shall be installed in compliance with at least one of the following: 1. A 4-inch (101.6 mm) thick base of 1/2 inch (12.7mm) or larger clean aggregate shall be provided with a vapor barrier in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, ACI 302.2R-06. 2. Other equivalent methods approved by the enforcing agency. 3. A slab design specified by a licensed design professional. 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19 percent moisture content. Moisture content shall be verified in compliance with the following: 1. Moisture content shall be determined with either a probe-type or contact-type moisture meter.Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements found in Section 101.8 of this code. 2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (1219 mm) from the grade stamped end of each piece verified. 3. At least three random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing. Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. Wet-applied insulation products shall follow the manufacturers' drying recommendations prior to enclosure. 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 Bathroom exhaust fans. Each bathroom shall be mechanically ventilated and shall comply with the following: 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control. a. Humidity controls shall be capable of adjustment between a relative humidity range less than or equal to 50% to a maximum of 80%. A humidity control may utilize manual or automatic means of adjustment. b. A humidity control may be a separate component to the exhaust fan and is not required to be integral (i.e., built-in) Notes: 1. For the purposes of this section, a bathroom is a room which contains a bathtub, shower or tub/shower combination. 2. Lighting integral to bathroom exhaust fans shall comply with the California Energy Code. 4.507 ENVIRONMENTAL COMFORT 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. Heating and air conditioning systems shall be sized, designed and have their equipment selected using the following methods: 1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J - 2011 (Residential Load Calculation), ASHRAE handbooks or other equivalent design software or methods. 2. Duct systems are sized according to ANSI/ACCA 1 Manual D - 2014 (Residential Duct Systems), ASHRAE handbooks or other equivalent design software or methods. 3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S - 2014 (Residential Equipment Selection), or other equivalent design software or methods. Exception:Use of alternate design temperatures necessary to ensure the system functions are acceptable. TABLE 4.504.1 - ADHESIVE VOC LIMIT1,2 (Less Water and Less Exempt Compounds in Grams per Liter) ARCHITECTURAL APPLICATIONS VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 4.504.2 - SEALANT VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter) SEALANTS VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 TABLE 4.504.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIF. AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIF. CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16" (8 MM). TABLE 4.504.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT-HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. DIVISION 4.5 ENVIRONMENTAL QUALITY (continued) 4.504.3 CARPET SYSTEMS. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS. Where resilient flooring is installed , at least 80% of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. hhtps://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.5 COMPOSITE WOOD PRODUCTS. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), by or before the dates specified in those sections, as shown in Table 4.504.5 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269, European 636 3S standards, and Canadian CSA 0121, CSA 0151, CSA 0153 and CSA 0325 standards. 5. Other methods acceptable to the enforcing agency. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AY N/AY N/AY N/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 2 (July 2024 Supplement)Y = YES N/A = NOT APPLICABLE RESPON. PARTY = RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DESIGNER ELIZABETH CAO 01-13-2026 DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 A0.5 CAL GREEN STANDARDS 3 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 3 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N 05 - 0 8 - 2 6 B U I L D I N G C O R R E C T I O N DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO PL PL (E) DRIVEWAY (E) MAIN HOUSE (UNPERMITTED - TO BE DEMO) (E) PATIO COVER (E) ENTRY PL PL SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N A1.0 EXISTING ARCHITECTURAL SITE PLAN EXISTING ARCHITECTURAL SITE PLAN SCALE: 3/16" = 1'-0" SITE PLAN KEYNOTES 1 EXISTING PROPERTY LINE 2 STOOP W/ 2% MAX. SLOPE AWAY FROM BLDG - PROVIDE AT EACH EXTERIOR DOOR, TO BE THE WIDTH OF THE DOOR OPENING AT NO LESS THAN 36" MIN. WIDE AND TO HAVE A LENGTH OF 36" MIN. IN THE DIRECTION OF TRAVEL (CRC R311.3) 1 SEE LANDSCAPE PLAN FOR LANDSCAPE & HARDSCAPE SCOPE OF WORK SITE NOTES 1. ALL INFORMATION IS EXISTING UNLESS NOTED OTHERWISE. SEE SITE SURVEY PLAN FOR ADD'L INFO. 2. ALL SURFACE WATER SHALL DRAIN AWAY FROM STRUCTURES 3. COMPLY WITH THE MINIMUM SLOPE AT THE FOLLOWING AREAS (NBMC 15.10.120 F): EARTH 2.0% CONCRETE 0.5% CONCRETE GUTTER IN PAVED AREA 0.2% ASPHALT 1.0% 4. REFER TO LANDSCAPE DRAWINGS FOR ALL HARDSCAPE, EXTERIOR RETAINING WALLS, GARDEN WALLS & GATES, A/C PAD SIZE & LOCATION, EXTERIOR STAIRS, OUTDOOR SHOWER, PLANTING AREAS, GARDEN LIGHTING, BBQ AREA, FIRE PIT, SPORTS COURT, DECKS NOT ATTACHED TO HOUSE, DRIVEWAY APPROACH, BIO RETENTION, EXTERIOR GUARDRAIL & HANDRAIL DESIGN. REFER TO CIVIL & SITE STRUCTURAL DRAWINGS FOR ADD'L INFO. 5. REFER TO CIVIL & SITE STRUCTURAL DRAWINGS FOR ADD'L INFO. N 1 DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO WH DW (E) FAMILY ROOM(E) KITCHEN(E) DINING (E) RESTROOM (E) 2-CAR GARAGE (E) LIVING ROOM HALL 6 1 (E) CLOSET 3 1 1 5 2 1 9 6 6 8 10 11 (UNPERMITTED - TO BE DEMO) (E) PATIO COVER (E) MAIN BEDROOM 1 (E) BEDROOM 2 (E) W.I.C. (E) OPEN TO BELOW 1 9 1 2 (E) BEDROOM 3(E) BEDROOM 4 (E) CLOSET (E) CLOSET (E) CLOSET 7 (E) BATH 2 (E) BATH 1 HALL 4 SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N A2.1 DEMOLITION FLOOR PLAN DEMO FLOOR PLAN - FIRST FLOOR SCALE: 1/4" = 1'-0" DEMO FLOOR PLAN - SECOND FLOOR SCALE: 1/4" = 1'-0" DEMO FLOOR PLAN NOTES 1. IF REQUIRED, ASBESTOS REMOVAL SHALL COMPLY WITH LOCAL, STATE, AND FEDERAL ASBESTOS REGULATIONS 2. CONSULT WITH OWNER REGARDING THE SALVAGE OR RELOCATIONS OF ALL ITEMS. 3. VERIFY EXISTING ELECTRICAL FOR WALLS TO REMAIN. SEE UTILITY PLAN FOR ADDITIONAL NOTES. 4. GC TO CONSULT WITH STRUCTURAL ENGINEER PRIOR TO ANY REMOVAL OF STRUCTURAL MEMBER FOR REQUIRED TEMPORARY SHORING. GRAPHIC LEGEND PORTION OF (E) FLOOR / FLOOR SLAB TO BE REMOVED SYMBOL DESCRIPTION STRUCTURAL INFILL AT (E) FLOOR OPENING EXISTING TO REMAIN EXISTING TO BE REMOVED DEMO FLOOR PLAN KEYNOTES 1 REMOVE EXISTING INTERIOR WALL AND REROUTE ELECTRICAL AS NEEDED. PATCH INTERIOR FINISHES WHERE OCCURS, MATCH ADJ. FINISH 2 REMOVE EXISTING INTERIOR DOOR & ITS ENTIRETY 3 REMOVE EXISTING CABINET, FINISHES, AND COUNTER TOP. PREP FOR NEW AND PROVIDE BACKING WHERE MISSING OR DAMAGED. 4 REMOVE EXISTING CASEWORK. PREP FOR NEW AND PROVIDE BACKING WHERE MISSING OR DAMAGED. 5 REMOVE EXISTING PLUMBING FIXTURES. 6 REMOVE EXISTING APPLIANCES AND REINSTALL, SEE PROPOSED FLOOR PLAN FOR NEW LOCATION. REPAIR OR REPLACE DAMAGED/OUTDATED GAS/WATER LINES AND/OR VALCES, VENT PIPES, ETC. REF. 7 REMOVE EXISTING SHOWER AND PREP FOR NEW. 8 REMOVE EXISTING CEILING AND PREP FOR NEW VAULTED CEILING TO MATCH ADJACENT. 9 REMOVE EXISTING BEAM AND PREP FOR NEW BEAM PER STRUCTURAL. 10 REMOVE WASHER & DRYER, RELOCATE EXISTING VENT TO O.S.A. AND GAS & ELECTRIC HOOK-UP, PLUMBING. SEE PROPOSED FLOOR PLAN FOR NEW LOCATION. 11 REMOVE FIREPLACE MANTEL, HEARTH, ADJACENT FINISHES & SHUT OFF GAS VALVE TO THE FIREPLACE. PREP & INFILL WALL, FINISH TO MATCH ADJACENT SURFACE N N 1 DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO WH (E) FAMILY ROOM VAULTED CLG. (N) KITCHENVAULTED CLG. (E) DINING (E) 2-CAR GARAGE VAULTED CLG. (E) LIVING ROOM WH W/D DW ROOM (N) LAUNDRY (E) ENTRY (E) MAIN BEDROOM 1 (E) BEDROOM 2 (E) W.I.C. (E) VAULTED CLG' (E) OPEN TO BELOW (E) BEDROOM 3(E) BEDROOM 4 (E) CLOSET (E) CLOSET (E) CLOSET (E) BATH 2 (E) BATH 1 HALL 1 2 3 4 7 7 5 15 4 12 64 17 16 15 11 14 13 12 8 4 18 (E) RESTROOM 2b 19 2 A5.0 1 A5.0 2 A5.0 1 A5.0 SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 A3.1 PROPOSED FLOOR PLAN PROPOSED FIRST FLOOR PLAN SCALE: 1/4" = 1'-0" GRAPHIC LEGEND 2X4 STUD WALL. PROVIDE R-# INSULATION PER T-24 CALCS. SEE STRUCT. FOR SHEAR WALL, ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED SYMBOL DESCRIPTION 2X6 STUD WALL. PROVIDE R-# INSULATION PER T-24 CALCS. SEE STRUCT. FOR SHEAR WALL, ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED FLOOR PLAN NOTES 1. TEMPERED GLASS IS REQUIRED FOR GLAZING ENCLOSURES OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS WHERE THE BOTTOM EXPOSED EDGE IS LESS THAN 60", MEASURED VERTICALLY, ABOVE A STANDING OR WALKING SURFACE. 2. CEMENT, FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER REINFORCED GYPSUM BACKERS SHALL BE USED AS BACKERS FOR WALL TILE AND CEILING PANELS IN TUB AND SHOWER AREAS (R702.4.2 CRC) AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 3. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS, AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO EXTEND TO A HEIGHT OF A MIN. OF 6' ABOVE THE FLOOR. (R307.2 CRC). 4. SHOWER COMPARTMENTS SHALL BE NOT LESS THAN 1,024 SQ. IN. AND ALSO BE CAPABLE OF ENCOMPASSING A 30" DIAMETER STANDARD PREFAB 30'X60" EXEMPT (408.6 CPC) 5. WATER CLOSET SHALL HAVE 15" TO ANY WALL OR OBSTRUCTION ON EACH SIDE OF ITS CENTERLINE AND A 24" CLEAR SPACE IN FRONT. 6. NEWLY INSTALLED PLUMBING FIXTURES SHALL BE WATER-CONSERVING IN COMPLIANCE WITH THE CALIFORNIA PLUMBING CODE AND GREEN BUILDING STANDARDS. WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH, SHOWERHEADS SHALL NOT EXCEED 1.8 GPM AT 80 PSI AND NEW LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GPM AT 60 PSI. (CPC 407.2, 408.2 & 411.2) (CGC 4.303.1). 7. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL SHOWER-HEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GPM AT 80 PSI, OR THE SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER OUTLET TO BE IN OPERATION AT A TIME. (CGC 4.303.1.3.2) NOTE: A HAND-HELD SHOWER SHALL BE CONSIDERED A SHOWERHEAD. 8. INT. WALLS & FLRS. INSULATED FOR ENERGY & ACOUSTIC ATTENUATION 9. LEVEL 5 SMOOTH DRYWALL FINISHES 9.1. RETURN AT ALL WINDOWS 9.2. NO CASING AROUND ALL DOORS, KERFED JAMB TYP. 9.3. NO BASEBOARD, 3/4" ALUMINUM REVEAL - FIRST FLOOR ONLY 10. GC SHALL INCORPORATE ALL SILL PL. WP. FLASHING, UNDER TILE WATERPROOFING & SLOPE INCLUDING DOORS & WINDOWS FLEXIBLE FLASHING PER SOILS REPORT RECOMMENDATION, STRUCT. DWG.'S , & WATER PROOFING CONSULTANT RECOMMENDATIONS AT A0.3. 11. LANDING OR FINISHED FLOORS AT REQUIRED EGRESS DOOR SHALL BE NOT MORE THAN 1-1/2 INCHES LOWER THAN THE TOP OF THE THRESHOLD. EXCEPTION: THE LANDING OR FLOOR ON THE EXTERIOR SIDE SHALL BE NOT MORE THAN 7-3/4 INCHES BELOW THE TOP OF THE THRESHOLD PROVIDED THAT THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR. CRC 311.3.1 12. PER SECTION 4.303.1 OF 2022 CGBSC: EXISTING NONCOMPLIANT PLUMBING FIXTURES SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES FOR A RESIDENTIAL BUILDING UNDERGOING PERMITTED ADDITIONS, ALTERATIONS, OR IMPROVEMENTS. DOOR TAG: SEE SHEET AD1.0 FOR ADD'L INFO.# KEYNOTES 1 NEW 38" HIGH LOW WALL 2 NEW INTERIOR GUARDRAIL / HANDRAIL, SEE DTL 14 & 15 / AD2.0 2b NEW INTERIOR HANDRAIL, SEE DTL 15 / AD2.0 3 PATCH AND REPAIR WALL AS REQUIRED 4 NEW CASEWORK 5 UNDERMOUNTED SINK AND FAUCET. SEE FLOOR PLAN NOTE #6 6 NEW KITCHEN ISLAND 7 NEW / RELOCATED APPLIANCES. FOR THE RANGE SEE 16 / AD2.0 8 NEW CASEWORK WITH LAVATORY AND FAUCET - SEE FLOOR PLAN NOTE #6 9 NEW FLOOR MOUNTED TOILET - SEE FLOOR PLAN NOTE #5 & #6 10 NEW 34" SQUARE CORNER SHOWER WITH SLIDING FRAMED GLASS DOOR - SEE FLOOR PLAN NOTE #1, #3, #4, #6, & #7. FINISH SELECTION PER OWNER 11 NEW SHOWER, HOTMOPPED AT FRAMING AND FLOORING, PROVIDE 6 FT. HIGH MIN. NON-ABSORBENT FINISH - SEE FLOOR PLAN NOTE #3, #4, #6, & #7. FINISH SELECTION PER OWNER 12 NEW SHOWER SEAT, FINISH TO MATCH ADJACENT WALL FINISH 13 TEMPERED GLASS SHOWER ENCLOSURE, SLIDING GLASS DOOR - SEE FLOOR PLAN NOTE #1 14 NEW RAIN SHOWER HEAD - SEE FLOOR PLAN NOTE #7 15 NEW BEAM, SEE STRUCTURAL 16 NEW WALL INFILL AT FIRE PLACE AND ROOF OPENING OF THE CHIMNEY TO BE CLOSED OFF. 17 NEW STACKED WASHER / DRYER 18 GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AS LISTED BELOW. (CRC R302.5) · FROM ALL HABITABLE ROOMS: NOT LESS THAN 5/8" TYPE 'X' GYP BD, SEE DTL 2 & 3 / AD2.0 · PENETRATIONS THRU WALLS OR CEILING SEPARATING THE RESIDENCE FROM THE GARAGE (SUCH AS THOSE FOR VENTS, PIPES, DUCTS, CABLES, AND WIRES) SHALL BE PROTECTED WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAMES AND PRODUCTS OF COMBUSTION (CRC R302.5) · DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILING SEPARTING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN. NO. 26 GA. SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE OPENINGS INTO THE GARAGE (CRC R302.5.2) 19 PROVIDE 1/2" GYP. BD. WALL FINISH, UNDER STAIR SURFACE AND ANY SOFFIT PER CRC R302.7 PROPOSED SECOND FLOOR PLAN SCALE: 1/4" = 1'-0"N N 2 2 2 2 2 2 2 3 3 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 3 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N 05 - 0 8 - 2 6 B U I L D I N G C O R R E C T I O N DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO WH W/D DW 4a 4a 4a4a 3 GFCIAFCI SCM AFCI AFCI 3D D D 2a UC GFCIGFCICW GFCI GFCI 2a2a VS WP 240V WH (E) FAMILY ROOM VAULTED CLG. (N) KITCHEN VAULTED CLG. (E) DINING (E) 2-CAR GARAGE VAULTED CLG. (E) LIVING ROOM (E) RESTROOM ROOM (N) LAUNDRY (E) ENTRY (E) (E) (E) S S S SCM (E) (E) S SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 UTILITY SYMBOLS J J UC WP GFCI GFCI GDOSM AFCI WPD 220V 240V GFCI 3 4 D DR VS PC WP UPDN 2a 2b 4a 4b VP2 VP4 MS2a MS2b MS4a MS4b WP WP MS MS HB CW T S SCM SM CH EXHAUST FAN W/ HUMIDISTAT CONTROL EXHAUST FAN & LIGHT COMBINATION W/ HUMIDISTAT CONTROL THERMOSTAT CEILING FAN W/ LIGHT, REMOTE CONTROLLABLE & DIMMABLE. PROVIDE SUPPORT PER MFR. REQUIREMENTS. SMOKE DETECTOR SMOKE & CARBON MONOXIDE COMBINATION DETECTOR GAS SUPPLY APPLIANCE WATER LINE HOSE BIBB, VERIFY EXISTING & CONFIRM NEW W/ OWNER DOOR CHIME / INTERCOM SURFACE MOUNTED CEILING PATIO HEATER - ELECTRIC RECESSED CEILING PATIO HEATER - ELECTRIC IAQ FAN FAN VENTILATION RATE METHOD (ASHRAE SECTION 4.1.1) WALL MOUNTED ILLUMINATED HOUSE NUMBERS PER CITY STANDARDS. VERIFY FONT W/ OWNER. UNDER TOE KICK MOUNTED LED LINEAR FIXTURE W/ MOTION SENSOR UNDER CABINET MOUNTED LED LINEAR FIXTURE RECESSED WALL MOUNTED WATERPROOF WALKWAY LIGHT FIXTURE 4" RECESSED LIGHT FIXTURE W/ MOTION SENSOR 4" RECESSED LIGHT FIXTURE W/ MOTION SENSOR, ADJUSTABLE RECESSED WALL MOUNTED WATERPROOF WALKWAY LIGHT FIXTURE W/ MOTION SENSOR CEILING MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE, WATERPROOF 2" RECESSED LIGHT FIXTURE VAPOR PROOF 2" RECESSED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE, WALL WASHER 4" RECESSED LIGHT FIXTURE 2" RECESSED LIGHT FIXTURE W/ MOTION SENSOR VAPOR PROOF 4" RECESSED LIGHT FIXTURE 2" RECESSED LIGHT FIXTURE, ADJUSTABLE 4" RECESSED LIGHT FIXTURE, ADJUSTABLE 2" RECESSED LIGHT FIXTURE W/ MOTION SENSOR, ADJUSTABLE WALL MOUNTED LIGHT FIXTURE, WALL WASHER, UPLIGHT & DOWNLIGHT 2" CEILING MOUNTED SPOTLIGHT FIXTURE, ADJUSTABLE, TYP. 4" CEILING MOUNTED SPOTLIGHT FIXTURE, ADJUSTABLE, ONLY AT GARAGE WALL SWITCH W/ MANUAL ON-AUTO OFF (ON PHOTO CELL) AT EXTERIOR FIXTURES. WALL SWITCH AT +36" ABOVE FLOOR, +8" ABOVE COUNTERS 3 WAY WALL SWITCH AT +36" ABOVE FLOOR, +8" ABOVE COUNTERS 4 WAY WALL SWITCH AT +36" ABOVE FLOOR, +8" ABOVE COUNTERS WALL SWITCH W/ DIMMER AT +36" ABOVE FLOOR, +8" ABOVE COUNTERS WALL SWITCH W/ DIMMER & REMOTE AT +36" ABOVE FLOOR, +8" ABOVE COUNTERS WALL SWITCH W/ MANUAL ON-AUTO OFF (VACANCY SENSOR) & DIMMER AT +36" ABOVE FLOOR, +8" ABOVE COUNTERS 110V DUPLEX OUTLET AT +12" ABOVE FLOOR U.N.O. 110V WATER PROOF DUPLEX OUTLET AT +12" ABOVE FLOOR U.N.O. 110V GROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLET 110V DUPLEX OUTLET UNDER COUNTER FOR USE OF HAIR TOOLS. VERIFY MOUNTING HT. & LOCATION W/ CABINET CONFIGURATION. JUNCTION BOX FOR FUTURE CEILING FAN. 110V HALF-HOT SWITCHED DUPLEX OUTLET AT +12" ABOVE FLOOR U.N.O. 220V WATER PROOF OUTLET W/ DISCONNECT 110V ARC-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLET AT +12" ABOVE FLOOR U.N.O. COMBO TELEPHONE & CABLE / TV/ HDMI WALL MOUNTED JUNCTION BOX 110V DUPLEX OUTLET, RECESSED FLOOR 110V GROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLET, IN-SURFACE 240V SPECIALTY OUTLET FOR EV CHARGING STATION. VERIFY NEMA CONFIGURATION WITH MANUFACTURE AND/OR INSTALLER 110V GROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX OUTLET FOR SIDE MOUNTED GARAGE DOOR OPENER LIGHT FIXTURES IN CLOTHES CLOSET SHALL BE PLACED MINIMUM OF 12" AWAY FROM WALLS & MINIMUM OF 12" AWAY FROM CLOTHES PER CEC. ART. 410.16 AT BATHROOMS WITH A BATHTUB, SHOWER OR SPA OR SOME SIMILAR SOURCE OF MOISTURE TO BE MECHANICALLY VENTILATED A MIN. OF 50 CFM OF AIR AND BE SWITCHED SEPARATELY FROM LIGHTING. THE DUCT MUST TERMINATE ON THE EXTERIOR NOT LESS THAN 3 FEET FROM OPENINGS INTO THE BUILDING. SMOKE DETECTORS PER CBC SEC. R314. A. SHALL BE INSTALLED ON EACH FLOOR IN ACCORDANCE WITH MFR'S LISTING B. SHALL BE MOUNTED ON THE CEILING OR WALL AT A CENTRAL POINT OR AREA GIVING ACCESS TO ROOMS USED FOR SLEEPING C. SHALL BE INSTALLED IN CLOSE PROXIMITY TO THE STAIRS GIVING ACCESS TO ROOMS USED FOR SLEEPING D. SHALL BE HARD WIRED, INSTALLED WITH A BATTERY BACKUP AND SHALL EMIT A SIGNAL WHEN BATTERY IS LOW E. SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS WITHIN A UNIT F. SMOKE ALARMS/DECTORS SHALL BE AT 6FT FROM PERMANENTLY INSTALLED COOKING APPLIANCES. WHEN BETWEEN 6FT - 10FT, THE SYSTEM SHALL BE A PHOTOELECTRIC SYSTEM AND WHEN BETWEEN 10FT - 20 FT THE SYSTEM SHALL BE A PHOTOELECTRIC SYSTEM OR AN IONIZATION SYSTEM WITH A SILENCING SWITCH (CRC R314.3.3) CARBON MONOXIDE ALARMS PER CRC SECTION R315: A. SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S) AND AT EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENT IN ACCORDANCE WITH MANUFACTURERS LISTING B. SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITH FUEL BURNING APPLIANCES OR WITH ATTACHED GARAGES. C. SHALL BE HARD WIRED, INSTALLED WITH A BATTERY BACKUP. PROVIDE OUTLET AND LIGHTS IN ATTICS CONTAINING FAU'S PROVIDE CONVENIENCE OUTLET IN EACH BATHROOM, POWDER AND LAUNDRY WITHIN 3 FT. OF BASIN EDGE, CEC ART. 210.52(0). SUCH OUTLETS SHALL BE APPROVED GROUND FAULT CIRCUIT PROTECTED (GFI,) CEC ART. 210.8(A)1. OUTLETS SHALL BE SUPPLIED BY A MINIMUM OF ONE 20-AMPERE BRANCH CIRCUIT. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM, CEC ART. 210.11(C)3. PROVIDE AT LEAST ONE 125 VOLT SINGLE PHASE RECEPTACLE IN GARAGE &OUTDOORS, CEC ART. 210.52(G). THIS CIRCUIT SHALL BE GROUND FAULT CIRCUIT PROTECTED (GFI) & WATERPROOF WHEN EXTERIOR, CEC. ART. 210.8(A) 2, 3. ALL KITCHEN 125VOLT SINGLE PHASE 15 &2 0 AMP RECEPTACLES SERVING COUNTER TOP SURFACES SHALL BE GROUND FAULT CIRCUIT INTERRUPTED (GFI), CEC ART. 210.8(A) 6. PERMANENTLY INSTALLED LUMINAIRES IN KITCHENS SHALL BE HIGH EFFICACY LUMINAIRES AND UP TO 50 PERCENT OF THE TOTAL RATED WATTAGES CAN BE NON HIGH EFFICACY LUMINARIES CONTROLLED WITH SEPARATE SWITCH, PER ENERGY CODE SEC. 150(K) FAMILY ROOMS, DINING ROOM, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS, 15 &2 0 AMP OUTLETS SHALL BE ARC FAULT CIRCUIT INTERRUPTED, COMBINATION TYPE AFCI REQUIRED PER CEC ART.210.12(A) ALL EXHAUST FANS MUST BE SPECIFIED AT A NOISE RATING OF A MAXIMUM 1 "SONE" (FOR CONTINUOUS USE CALCULATION) OR 3 "SONE" (FOR INTERMITTENT USE CALCULATION) ALL ELECTRICAL OUTLETS SPECIFIED IN CEC 210.52 SHALL BE TAMPER RESISTANT. GROUND FAULT PROTECTION IS REQUIRED FOR ALL GRADE ACCESS EXTERIOR OUTLETS, OUTLETS IN BATHROOMS, KITCHENS, BASEMENTS, CRAWL SPACES, GARAGES AND WITHIN 6' OF ANY WATER SOURCE PER ARTICLE 210-8 OF THE CEC. ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN KITCHEN, LAUNDRY AREAS, FAMILY, LIVING, DINING, BED, SUN AND RECREATION ROOM , DENS, LIBRARIES, CLOSETS, HALLWAYS OR SIMILAR AREAS SHALL BE PROTECTED BY ARC-FAULT CIRCUIT INTERRUPTERS, COMBINATION TYPE PER ARTICLE 210-12 OF THE CEC. BATHROOM RECEPTACLES SHALL BE SERVED BY A DEDICATED 20 AMP CIRCUIT - PER CEC SECT. 210.11 (c)3 ELECTRICAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. SEE GN-3 DIVISION 16 FOR ADDITIONAL INFORMATION. CONTRACTOR SHALL INSTALL ALL FIXTURES AND APPLIANCES PER MANUFACTURERS' SPECIFICATIONS. HEIGHTS OF OUTLETS ARE MEASURED FROM FINISHED FLOOR TO CENTERLINE OF ELECTRICAL BOX. VERIFY LOCATION OF FLOOR OUTLETS, PHONE JACKS, ETC. WITH OWNER AND ARCHITECT IN FIELD. GARAGE, LAUNDRY ROOM, UTILITY ROOM SHALL HAVE HIGH EFFICACY LIGHTING AND VACANCY SENSORS. A3.4 PROPOSED UTILITY PLAN N N EXISTING UTILITY PLAN - SECOND FLOOR SCALE: 1/4" = 1'-0" PROPOSED UTILITY PLAN - FIRST FLOOR SCALE: 1/4" = 1'-0" 2 2 3 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 3 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N 05 - 0 8 - 2 6 B U I L D I N G C O R R E C T I O N DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO ROOM (N) LAUNDRY (E) RESTROOM VAULTED CLG. (E) LIVING ROOM (E) BEDROOM 2 HALL VAULTED CLG. (E) DINING / KITCHEN BEYOND (E) FAMILY RM VAULTED CLG. (E) LIVING ROOM 34 " M I N . T O 3 8 " M A X HA N D R A I L F R O M FI N . S U R F A C E 42 " M I N A T G A U R D R A I L FR O M F I N I S H E D S U R F A C E NEW GUARDRAIL & HANDRAIL, SEE 14/AD2.0 SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 3 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N 05 - 0 8 - 2 6 B U I L D I N G C O R R E C T I O N A5.0 SECTIONS - BUILDING SECTION NOTES 1. ALL WALLS & BETWEEN FLOORS INSULATED FOR ENERGY & SOUND 2. PLACE FOOTING DRAIN 4" BELOW T.O. FLOOR SLAB 3. ALL STRL. MEMBER SHOWN ARE FOR REFERENCE ONLY, SEE STRL. DOCUMENTS. BUILDING SECTION - LONGITUDE SCALE: 1/4" = 1'-0"1 BUILDING SECTION - TRANSVERSE SCALE: 1/4" = 1'-0"2 2 3 DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO DOORS SYMBOL SIZE NEW / REPLACE / EXIST ROOM U FACTOR SHGC REMARKS 1 2'-6" X 6'-8"N GARAGE NA NA SEE NOTE #2, SOLID WOOD DOORS NOT LESS THAN 1 3/8" IN THICKNESS, SOLID OR HONEYCOMB - CORE STEEL DOORS NOT LESS THAN 1 3/8" THICK, OR 20-MIN FIRE RATED DOORS. DOOR SHALL BE SELF LATCHING AND EQUIPPED WITH SELF-CLOSING OR AUTOMATIC CLOSING (CRC 302.5.1) 2 2'-4" X 6'-8" N BATH 3 N/A N/A SEE NOTE #2 3 2'-6" X 6'-8"N LAUNDRY N/A N/A SEE NOTE #2 4 3'-0" X 6'-8" N MAIN BEDROOM 1 N/A N/A SEE NOTE #2 WINDOWS SYMBOL SIZE OPERA BILITY NEW / REPLACE / EXIST ROOM HEAD HT EGRESS U FACTOR SHGC REMARKS NO T E S NO T E S GENERAL NOTE: - FIELD VERIFY ALL DOORS BEFORE ORDERING - ALL INTERIOR DOORS TO HAVE FLUSH HEADERS A = AWNING C = CASEMENT F = FIXED DH = DOUBLE HUNG SH = SINGLE HUNG S = SLIDER BF = BI-FOLD GENERAL NOTE: -FIELD VERIFY ALL WINDOWS BEFORE ORDERING APPLIANCES SYMBOL APPLIANCE MFR. MODEL REMARKS RF REFRIGERATOR FDG DW DISHWASHER RG RANGE HD VENT HOOD O/M OVEN MICROWAVE GD GARBAGE DISPOSAL W WASHER D DRYER WH WATER HEATER 1. VERIFY MINIMUM REQUIREMENTS WITH T-24 CALCS. 2. VERIFY FINAL SELECTION WITH OWNER. BY OWNER PLUMBING SYMBOL FIXTURE MODEL REMARKS REMARKS LAV LAVATORY TBD WC WATER CLOSET TBD SH SHOWER TBD TS TUB / SHOWER TBD NO T E S MECHANICAL SYMBOL EQUIPMENT NEW/EXIST. MANUFACTURER MODEL REMARKS BY OWNER NO T E S 1. VERIFY FINAL DOOR SELECTION W/ OWNER. 2. INTERIOR DOORS: 1 3/4'' SOLID WOOD, STAIN GRADE, SLAB, KERFED JAMB, U.N.O. 3. GLASS IN DOORS TO BE DUAL GLAZED TEMPERED, LOW-E (MIN. U FACTOR AND SHGC PER T-24). NO T E S NEW WINDOWS TO BE WESTERN PERFORMANCE LINE 7000, LOW E DUAL GLAZED: 1. (MIN. UFACTOR AND SHGC PER T-24). REFER TO ELEVATION FOR OPERABILITY. 2. NEW WINDOW FENESTRATION MUST HAVE TEMPORARY AND PERMANENT LABELS. 3. PROVIDE MIN. EGRESS WINDOW AS FOLLOWS: a. MINIMUM NET 5.7 SQUARE FEET OF OPENABLE AREA (MINIMUM OF 5.0 NET SQUARE FEET REQUIRED FOR GRADE LEVEL BEDROOMS) b. MINIMUM NET 20” CLEAR WIDTH WHEN OPEN c. MINIMUM NET 24” CLEAR HEIGHT WHEN OPEN d. MAXIMUM HEIGHT OF 44” FROM THE FINISHED FLOOR TO THE BOTTOM OF THE CLEAR OPENING 4. TEMPERED GLAZING PER CRC R308.4 AND CBC 2406.4 5. SKYLIGHT GLAZING USE i89 COATING ON INTERIOR SURFACE PER MANUFACTURER. BY OWNER SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N DOOR & WINDOW - SCHEDULES & DETAILS AD1.0 2 DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO 6" M I N . 4" M I N . HARDSCAPE AS OCCURS FINISH GRADE 2" M I N . SL 5 BASE AT STUCCO WALL SCALE: N.T.S. 6 CORNER WALL REINFORCEMENT PLAN -VIEW SCALE: N.T.S. BUILDING PAPER BUILDING PAPER 2X FRAMING, SEE FRAMING PLANS PLAN VIEWSHEATING PER STRUCTURAL STUCCO W/ CORROSION RESISTANT MTL LATH SHEATHING PER STRUCTURAL CORROSION RESISTANT METAL CORNER BEAD, G.C. TO VERIFY PROFILE PRIOR TO INSTALLATION ELASTOMERIC FLASHING 2" BRUSH COAT STUCCO FINISH BELOW SCREED PRESERVATIVE TREATED SILL PLATE PER CRC R317.1 IF OCCURS <8" ABOVE GRADE. 2x FRAMING W/ INSUL., TYP. SEALANT & BACKER ROD. CONC. STEM / RETAINING WALL - SEE STRUCT. DRAIN BD. O/ W.P., CONT. W.P. TO T.O. CONC. WEEP SCREED, CORROSION RESISTANT METAL WITH WEEP HOLES PER CODE REQUIREMENTS SHEATHING PER STRUCT. DWGS CONC. FLR. SLAB - SEE STRUCT. BUILDING PAPER LAP OVER C.R. METAL BASE SCREED BUILDING PAPER STUCCO W/ CORROSION RESISTANT MTL. LATH STUCCO W/ CORROSION RESISTANT MTL. LATH ELASTOMERIC FLASHING 2x FRAMING W/ INSUL., TYP. SHEATING PER STRUCT. DWG. BUILDING PAPER 7 CORNER WALL REINFORCEMENT PLAN -VIEW SCALE: N.T.S. CORROSION RESISTANT METAL CORNER BEAD, G.C. TO VERIFY PROFILE PRIOR TO INSTALLATION STUCCO WITH CORROSION RESISTANT METAL LATH 2x WOOD STUD 2x BASE PLATE SEALANT (CONT.) 3 1-HR. RATED INT. WALL AT FLOOR SCALE: N.T.S. 2 1-HR. RATED INT. WALL SCALE: N.T.S. 1 1/2" GLASS FIBER INSULATION 0.8 pcf, STAPLED TO STUDS IN STUD SPACE. RESILIENT CHANNELS 24" O.C. ATTACHED AT RIGHT ANGLES TO ONE SIDE OF STUDS WITH 6d COATED NAILS, 1 7/8" LONG, 0.086" SHANK, 1/4" HEADS. 1/2"x3" GYP. BD. FILLER STRIPS ATTACHED TO PLATE AT FLOOR LINE WITH 6d NAILS. (1) LAYER 5/8" TYPE 'X' GYP. BD. APPLIED PARALLEL TO CHANNELS WITH 1" TYPE 'S' DRYWALL SCREWS 6" O.C. AT HORIZONTAL JOINTS AND 12" O.C. AT INTERMEDIATE CHANNELS (1) LAYER 5/8" TYPE 'X' GYP. BD. APPLIED AT RIGHT ANGLES TO STUDS WITH 6d NAILS 8" O.C. 2x FIRE BLOCKING AT MID-HEIGHT RESILIENT CHANNELS 24" O.C. ATTACHED AT RIGHT ANGLES TO ONE SIDE OF STUDS WITH 6d COATED NAILS, 1 7/8" LONG, 0.086" SHANK, 1/4" HEADS. 1/2"x3" GYP. BD. FILLER STRIPS ATTACHED TO PLATE AT FLOOR LINE WITH 6d NAILS. (1) LAYER 5/8" TYPE 'X' GYP. BD. APPLIED PARALLEL TO CHANNELS WITH 1" TYPE 'S' DRYWALL SCREWS 6" O.C. AT HORIZONTAL JOINTS AND 12" O.C. AT INTERMEDIATE CHANNELS (1) LAYER OF 5/8" TYPE 'X' GYP. BD. APPLIED AT RIGHT ANGLES TO STUDS WITH 6d NAILS 8" O.C. 2x WOOD FRAMING AT 16" O.C. MAX. 1 1/2" GLASS FIBER INSULATION 0.8 pcf, STAPLED TO STUDS IN STUD SPACE. NOTES: 1) UL DESIGN - U305 2) STC 50 NOTES: 1) UL DESIGN - U305 2) STC 50 4 INTERIORS - LOW WALL SCALE: N.T.S. 1/2"x1" TRIM 2x FRAMING @ 16" O.C. 1/2" GYP. BOARD (TYP) 1" 2" OAK WOOD WALL CAP W/ 1/8" RADIUS EDGES - SECURE W/ RECESSED WD. SCREWS, PROVIDE WD. CAP FILLER 15 HANDRAIL - AT WALL SCALE: N.T.S. 5/8" TYPE "X" GYP. BD. SEE FLOOR PLAN 2x FRAMING METAL BRACKETS @ 5'-0" O.C.(MAX.) 1 1/2" CLEAR OF ALL FINISHED MATERIALS 1 1/4" MIN - 2" MAX. WIDE GRIP CIRCULAR METAL HANDRAIL 2x6 BACKING AT BRACKETS ALL METALS TO BE PRIMED SEE STRUCTURAL DRAWINGS FOR ALL FRAMING AND ATTACHMENTS AND PAINTED 11 2" CLR MIN 11 2" 34 " M I N T O 3 8 " M A X TO F I N I S H E D S U R F A C E 16 RANGE EXHAUST SYSTEM VENT SCALE: N.T.S. NOTE: LOCAL EXHAUST SYSTEM VENTED TO OUTDOORS, THE MINIMUM EXHAUST RATE SHALL FOLLOW TABLE 150.0-G. AT ELECTRICAL RANGE, NO GAS HOOKUP AT STOVE. ((CAL ENERGY CODE SECTION 150 (o)1G, EXC. 5 TO 150.2(a), & ASHRAE STD. 62.2). DWELLING UNIT FLOOR AREA (FT SQ) >1500 >1000-1500 750-1000 <750 HOOD OVER ELECTRIC RANGE 110 CFM 110 CFM 130 CFM 160 CFM HOOD OVER NATURAL GAS RANGE 180 CFM 250 CFM 280 CFM 280 CFM 2" 2" M I N L A P 2" STARTING AT THE BOTTOM OF THE WALL (SOLE PLATE), LAY BUILDING PAPER UNDER THE SILL STRIP. CUT AWAY ANY EXCESS BUILDING PAPER THAT MAY EXTEND ABOVE THE SILL FLANGE ON EACH SIDE OF THE OPENING. APPLY SUCCESSIVE LINES OF BUILDING PAPER OVER JAMB AND HEAD FLANGES , LAPPING EACH COURSE. PAPER SHOULD RUN CONTINUOUSLY OVER HEAD WITH NO SPLICES ABOVE WINDOW. CUT AWAY EXCESS WITH EDGE OF WINDOW OPENING. HEADER, TOP OF WINDOW OPENING. LEAST 12" WIDE WITH INSIDE EDGE OF FLASHING ALIGNED START JAMB STRIPS 2" BELOW THE SILL STRIP AND EXTEND JAMB STRIPS 12" ABOVE THE LOWER EDGE OF THE AFTER SILL STRIP IS IN PLACE, ATTACH JAMB STRIP AT APPLY A CONTINUOUS BEAD OF SEALANT TO THE BACK SURFACE OF THE WINDOW FLANGE. INSTALL WINDOW INTO ROUGH OPENING OVER SILL AND JAMB FLASHING STRIPS PER MANUFACTURER'S REQUIREMENTS. APPLY CONTINUOUS BEAD OF SEALANT TO THE FACE OF THE WINDOWS TOP FLANGE. ATTACH THE HEAD FLASHING OVER THE WINDOW FLANGE. THIS IS ANOTHER STRIP 12" WIDE WITH A 2" MINIMUM LAP BEYOND THE JAMB STRIPS. 4. EDGE OF WINDOW FLANGE HEAD STRIP 3. 2" 12 " 14" RUST-RESISTANT STAPLES. (VERIFY WIDTH OF FLASHING MATERIAL ATTACH SILL STRIP OF FLASHING MATERIAL AT LEAST 12" WIDE WITH THE TOP EDGE ALIGNED WITH THE TOP EDGE OF THE ROUGH SILL. EXTEND THIS SILL STRIP AT LEAST 14" BEYOND THE EDGE OF THE ROUGH OPENING FOR WINDOW, 2" BEYOND THE JAMB STRIP. ATTACH FLASHING WITH CORROSION RESISTANT NAILS OR JAMB STRIP HEADER 2. FRAMING SILL STRIP ROUGHED-IN OPENING WINDOW ROUGH SILL HEADER 1. COVER THE WIRE BACKING. NOTES: SECTION 1402.2 UNIFORM BUILDING CODE CALLS FOR FLASHING OF ALL EXTERIOR OPENINGS EXPOSED TO WEATHER TO MAKE THEM WEATHERPROOF. THIS IS OUR RECOMMENDED PROCEDURE FOR STANDARD FLASHING AT OPENINGS IN WOOD FRAMED EXTERIOR WALLS WHERE THE EXTERIOR WALL FINISH IS APPLIED OVER BUILDING PAPER OR FELT. USE "MOISTOP" FLASHING OR EQUAL WHENEVER POSSIBLE FOR FLASHING MATERIAL. CAULK BACK OF WINDOW FRAMES BEFORE SETTING. USE WINDOWS THAT ARE WATERTIGHT. LINE-WIRE, WHEN USE AS BACKING TO SUPPORT BUILDING PAPER BENEATH WIRE LATH FOR STUCCO, SHOULD BE INSTALLED ACCORDING TO INDUSTRY STANDARDS AND PRACTICE. NO ATTACHMENT DEVICE NOR THE WIRE BACKING SHOULD COVER OR PENETRATE FLASHING MATERIAL. PERIPHERAL FLASHING AT ALL EDGES OF WALL OPENING MUST THE WIDTH OF FLASHING MATERIAL SHALL PROVIDE FOR A MINIMUM LAP OF 6" AT VERTICAL AND 2" AT HORIZONTAL JOINTS AND OVERLAPS WITH OTHER WEATHER RESISTANT MATERIALS. TO ALLOW FOR MINIMUM LAPS AT EXPOSED WOOD TRIM CONDITIONS.) MINIMUM LAPS AT EXPOSED WOOD TRIM CONDITIONS.) (VERIFY WIDTH OF FLASHING MATERIAL TO ALLOW FOR MINIMUM LAPS AT EXPOSED WOOD TRIM CONDITIONS.) (VERIFY WIDTH OF FLASHING MATERIAL TO ALLOW FOR 12 APPLICATION AT OPENINGS STANDARD FLASHING MATERIAL SCALE: N.T.S.8 WINDOW CORNER TREATMENT SCALE: N.T.S. 50 lbs PER LINEAR FT THROUGH MAY NOT PASS 6" SPHERE ANY LOCATION ANY DIRECTION 200 lbs THROUGH 42 " M I N . MO R E MAY NOT PASS 4" SPHERE 30 " O R GU A R D R A I L 1. HANDRAILS SHALL NOT BE LESS THAN 34" OR MORE THAN 38" IN HEIGHT ABOVE THE STAIR NOSING. 2. HANDRAILS SHALL BE CONTINUOUS PER FLIGHT OF STAIRS. 3. HANDRAILS SHALL BE 1 1/2" CLEAR OF ALL ADJACENT FINISH MATERIALS AND ENDS SHALL RETURN TO WALL OR TERMINATE IN NEWEL POSTS OR SAFE TERMINALS. 4. HANDRAILS SHALL BE 1 1/4"-2" IN CROSS SECTIONAL DIMENSION, OR APPROVED EQUIVALENT, AND BE SMOOTH WITH NO SHARP EDGES/CORNERS. 5. STAIR AND RAILING SUPPLIER INSTALLER SHALL SATISFY ALL BUILDING DEPARTMENT APPROVAL REQUIREMENTS FOR THE PRODUCTS THEY PROVIDE OR INSTALL. 6. GUARDRAILS SHALL NOT BE LESS THAN 42" IN HEIGHT. 7. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS OR AN ORNAMENTAL PATTERN SUCH THAT A 4" DIAMETER SPHERE CANNOT PASS THROUGH. 8. THE GUARDRAIL CONSTRUCTION SHALL BE ABLE TO RESIST A LOAD OF 50 LBS PER LINEAR FOOT APPLIED HORIZONTALLY ALONG THE TOP RAIL. 9. THE TRIANGULAR OPENINGS AT STAIR TREAD, RISER, & BOTTOM SHALL BE SUCH THAT A 6" DIAMETER SPHERE CANNOT PASS THROUGH. 10. THE HANDRAIL CONSTRUCTION SHALL BE ABLE TO RESIST A LOAD OF 200 LBS APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP RAIL. 14 STAIR / HANDRAIL / GAURDRAIL TYPICAL SCALE: N.T.S. 2022 C.B.C. SECTION 509 SECTION 1003.3.3.2 TABLE 16B TYPICAL STAIR NOTES: THIS DIAGRAM ILLUSTRATES THE SPECIFIC REQUIREMENTS OF THE BUILDING CODE AND IS ONLY AN AID FOR BUILDING DESIGN AND CONSTRUCTION. SHEET NUMBER: SHEET TITLE: PHASE: O1Design Phone: 714-261-9576 email: o1designgroup@gmail.com DD NG U Y E N R E S I D E N C E 23 1 4 W S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 IS S U E D F O R : DA T E DE S C R I P T I O N #IS S U E D F O R : DA T E DE S C R I P T I O N #1 2 3 PL A N N I N G C O R R E C T I O N 03 - 2 0 - 2 6 B U I L D I N G C O R R E C T I O N 05 - 0 8 - 2 6 B U I L D I N G C O R R E C T I O N DETAILS AD2.0 GENERAL DETAIL NOTES 1. VERIFY LOCATION OF SHEATHING WITH STRUCTURAL . 2. STONE VENEER PRODUCTS VERIFY ALL SUBSTRATE REQUIREMENTS WITH MANUFACTURER PRIOR TO INSTALLATION STONE VENEER O/ MORTAR W/ CORROSION RESISTANT LATH W/ BUILDING PAPER, TYP. U.N.O. 3. BRICK VENEER PRODUCTS VERIFY ALL SUBSTRATE REQUIREMENTS WITH MANUFACTURER PRIOR TO INSTALLATION BRICK VENEER O/ MORTAR W/ CORROSION RESISTANT LATH W/ BUILDING PAPER, TYP. U.N.O. 4. ROOF CONCRETE TILE INSTALL AS REQUIRED PER ROOFING MATERIAL MANUFACTURER REQUIMRENTS 6. WHERE OCCURS, PROVIDE ELASTOMERIC FLASHING (ALT BID: CORROSION RESISTANT METAL FLASHING SHEET) 7. REFER TO DETAILS 8 & 12 / AD2.0 FOR FLASHING AND BUILDING PAPER INSTALLATION REQUIREMENTS AT OPENINGS AND WINDOW TREATMENT. 8. DECK TILE O/ 3/4" MORTAR W/ CORROSION RESISTANT LATH O/ DECKING WATERPROOFING MEMBRANE UNDERLAYMENT O/ PLYWOOD SHEATHING, TYPICAL U.N.O., INSTALL PER MANUFACTURER'S REQUIREMENTS. WHEN FASTENING THROUGH DECKING MEMBRANE UNDERLAYMENT, DRILL PILOT HOLE & FILL WITH POLYURETHANE CAULKING 2 2 2 3 3 DIGITAL SIGNATURE: 05-09-2026 DESIGNER ELIZABETH CAO Project Name : 2314 W. SAN LORENZO Client : Job :30424 Plan :REM 2022 CBC DESIGN CRITERIA: A.Code: 2022 CBC Wind Exposure: C, Speed = 95mph Seismic Design Category : D, Ss = 1.294, S1 = 0.464, SDS=1.035, SD1=0.568, RX =6.5, RY =6.5, Fa =1.2, Fv =1.8 B.Maximum 19% moisture content prior to Installation of Finish Material 4X Members: No. 2 or Better 6X, 8X Beams and Headers: No.1 or Better 2X Joists and Rafters: No. 2 or Better Plates and Blocking: Standard Grade or Better Studs: Stud Grade or Better Mud Sills: Pressure Treated Utility Grade or Better Parallam PSL Beams and Headers: Grade 2.0E DF, Fb = 2900 psi(MIN), FV = 290 psi(MIN) Versa-Lam LVL Beams and Headers: Grade 2.0E, Fb = 2900 psi(MIN), FV = 285 psi(MIN) TimberStrand LSL Beams and Headers: Grade 1.55E, Fb = 2325 psi(MIN), FV = 425 psi(MIN) TimberStrand LSL Rim Board and Headers: Grade 1.3E, Fb = 1700 psi(MIN), FV = 425 psi(MIN) Glu-Lam Beams and Headers: 24F-V4, DF/DF, 1.8E, Fb = 2400(T)/1850(B) psi (MIN), FV = 265 psi(MIN) C.N/A EXTERIOR WALL (WALL_E):DL = 15 INTERIOR WALL (WALL_I):DL = 10 PRIMARY ROOF (ROOF_P) Pitch:4 K = Increase for pitch: 1.05/12 2x10 16" O/C x K 3.40 Plywood(1/2") x K 1.63 1/2" Gyp. Board 2.20 Shingle x K 3.16 sprinkler:1.00 Misc:8.61 Snow Load:0.00 Dead Load:20.00 Live Load:20.00 ASCE Hazards Report Address: 2314 W San Lorenzo Ave Santa Ana, California 92704 Standard:ASCE/SEI 7-16 Latitude:33.708587 Risk Category:II Longitude:-117.899905 Soil Class:D - Default (see Section 11.4.3) Elevation:39.6533600779626 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Thu Sep 04 2025 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://ascehazardtool.org/Thu Sep 04 2025 SS : 1.294 S1 : 0.464 F a : 1.2 F v : N/A SMS : 1.553 SM1 : N/A SDS : 1.036 SD1 : N/A T L : 8 PGA : 0.554 PGA M : 0.665 F PGA : 1.2 Ie : 1 C v : 1.359 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Thu Sep 04 2025 Page 2 of 3https://ascehazardtool.org/Thu Sep 04 2025 Project Name : 2314 W. SAN LORENZO Client : Job :30424 Plan :REM 2022 CBC BEAM 1 (DROP): NEW DROP BEAM @ 1st Floor Loads (Downward +) SELF_WEIGHT 36 plf from 0.00ft to 25.00ft ROOF_P 460 PLF = 23.00' x (20.00+20.00)/2 from 0.00' to 19.00' ROOF_P 400 PLF = 20.00' x (20.00+20.00)/2 from 19.00' to 25.00' Reactions (D+Lr+L/Max. Load comb.) Down 5933/5933 5670/5670 Up 0/0 0/0 w/ 2-2X6 trim at support 1 (at 0'-0")(1) w/ 2-2X6 trim at support 2 (at 25'-0")(1) USE PARALLAM 5 1/4" x 18" 2.0E (Fb = 2800, Fv = 285) Critical Shear =5216 LB @ 1.50' 1.5xV/(F'v x A)=0.232 F'v = 356, A = 94.50 Critical Moment =36822 LB-FT @ 12.42' M/(F'b x S)=0.550 F'b = 2835, S = 283.50 Critical Deflection for TL = -0.810 INCH @ 12.50' ≤ L/300 = 1.000" Critical Deflection for LL = -0.359 INCH @ 12.50' ≤ L/600 = 0.500" 25.00 Shear Diagragm:D + Lr Moment Diagragm:D + Lr Deflection Diagram:D + Lr 5216 36822 -0.810 (1) selected post does not consider combined axial load and out-of-plane bending Project Name : 2314 W. SAN LORENZO Client : Job :30424 Plan :REM 2022 CBC Stud_Wall 1: (Ext.-Internal Zone) POST AT BEAM 1 Loads WALL_E 20 PLF = 15.00 x 1.33 from 0 to 12.5' Point from Support 1 of Beam 1 (5933 LB) WINDLOAD (HOR.) 16 PLF from 0.00' to 12.50' H= 12.50' Axial Force Diagram D + Lr Shear Diagram D + 0.6xW Moment Diagram D + 0.6xW Deflection Diagram D + 0.6xW 6183 97 305 0.067 Wind Load Analysis (Components & Cladding): Wind Exposure: C Wind Speed 95 mph Slope Roof: 5.0/12 Mean Roof height: 16' kh = 0.86 kzt = 1.00 kd = 0.85 GCp = 0.87(-0.97)(zone 4) GCpi = ±0.18 qh = 0.00256 x kh x kzt x kd x V² = 16.90 psf p = qh x (GCp ± GCpi ) = 19.49 psf Design Result: Critical Axial = 6183 LB @ 0.00' P/(Fc x A)= 0.54 (F'c = 590, A= 19.25) Critical Shear= 97 LB @ 12.50' 1.5xQ/(F v x A)= 0.03 (F'v = 288, A= 19.25) Critical Moment = 305 LB-FT @ 6.25' M/(F b x S)= 0.10 (F'b = 2153, S= 17.65) Critical Deflection = 0.067" @ 6.25'<= L/360 = 0.417" Bending and Axial Compression= (fc / F'c )² + fb / [F'b x (1-fc / Fce)] = 0.34 <= 1 (fc = 282, F'c = 604, fb = 149, F'b = 2153, Fce= 645) combination: D + 0.75x0.6xW + 0.75(L + Lr) @ 4'-11" Sill Plate Bearing stress = 321 psi Require Sill Plate DFL Construction (F'c┴= 692) USE DFL NO2 4 x 6,(F b = 900, Fc = 1350, Fv = 180) @ 16.0" O.C.(Plaster_or_stucco Finishing) Project Name : 2314 W. SAN LORENZO Client : Job :30424 Plan :REM 2022 CBC Footing/Pad: 1 NEW PAD FOOTING Soil Bearing(SB) = 1500 PSF post width parallel to footing(Bp) = 3.50" Loads: Weight of footing 225 PLF = 150 x 1.00' x 1.50' Weight of Pad 938 LB = 150 x 2.50' x 2.50' x 1.00' FLOOR_P 220 PLF = 8.00' x (15.00+40.00)/2 from 0.00' to 1.00' Point from Support 1 of Beam 1 (5933 LB) Total Weight(Wtotal ) = 445 PLF Total Point Load(P Total ) = 6870 LB Footing Width(Bf ) Required: 3.56" = (Wtotal / SB) = 445/1500 x 12 USE 12" Wide x 12" Deep Continuous Footing #4 Cont. @ T & B (U.N.O.) S = 3.50" + 2 x 18" = 39.50" Width 12" Capacity of Point Load on Footing(P cap ) = (SB x S x Width)/144 = 4938 LB Allowable Point Load on Footing(P Allow ) = Pcap - (Wtotal x S)/12 = 3473 LB Required Pad Area = Ptotal /SB = 6870 / 1500 = 4.58' USE 2'-6" SQ x 12" DEEP PAD (4)#4 @ Botom E.W. GENERAL REQUIREMENTS 1.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS, CONDITIONS AT THE JOB SITE, AND TO CROSS CHECK ALL DETAILS AND DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS WITH RELATED REQUIREMENTS ON THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND/OR CIVIL DRAWINGS AND NOTIFY THE ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO STARTING WORK. 2.IN ALL CASES WHERE A CONFLICT MAY OCCUR SUCH AS BETWEEN ITEMS INCLUDED IN THE SPECIFICATIONS AND NOTES ON THE DRAWINGS OR BETWEEN GENERAL NOTES AND SPECIFIC DETAILS, THE ENGINEER SHALL BE NOTIFIED AND HE WILL INTERPRET THE INTENT OF THE CONTRACT DOCUMENT. 3.EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN IN THE PLANS OR SPECIFICATIONS, ALL PHASES OF WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE CALIFORNIA BUILDING CODE, LATEST EDITION, AS WELL AS ALL APPLICABLE STATE AND LOCAL ORDINANCES. 4.IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THE STRUCTURAL DRAWINGS. 5.THE SLAB-ON-GRADE IS CONSIDERED A NON-STRUCTURAL COMPONENT AND IS THEREFORE NOT DESIGNED BY THE ENGINEER 6.THE USE OF THESE PLANS, DRAWINGS, SPECIFICATIONS, AND/OR ELEVATIONS IS RESTRICTED TO THE ORIGINAL USE FOR WHICH THEY WERE PREPARED AND FURNISHED TO THE CLIENT. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REUSE, REPRODUCTION OR OTHER PUBLICATION BY ANY METHOD IS PROHIBITED. 7.THE MEANS AND METHODS OF CONSTRUCTION, INCLUDING THE DESIGN, ADEQUACY AND SAFETY OF BRACING, SHORING, GUYING, AND ERECTION AS WELL AS THE SEQUENCE OF CONSTRUCTION HAVE NOT BEEN CONSIDERED BY THE EOR. THE ENGINEER AND HIS REPRESENTATIVES WILL NOT COVER SUCH ITEMS IN THE COURSE OF THE STRUCTURAL OBSERVATIONS. 8.DETAIL MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. 9.FOR ANY PRE-MANUFACTURED PRODUCTS OR MATERIALS OF CONSTRUCTION, CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH AND FOR PROPER EXECUTION OF MANUFACTURER'S INSTRUCTIONS, REQUIREMENTS AND CONDITIONS OF APPROVAL PRIOR TO INSTALLATION AND/OR USE. 10.WOOD FRAMING MEMBERS (INCLUDING WOOD SHEATHING) LESS THAN 8 INCHES FROM EXPOSED EARTH SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. 11.BECAUSE OF LOCATION SOME STRUCTURAL COMPONENTS ARE REQUIRED BY CODE TO BE PROTECTED FROM WATER/MOISTURE PENETRATION OR FROM FIRE DAMAGE. THE METHODS OF PROTECTION OF THESE STRUCTURAL COMPONENTS ARE NOT THE RESPONSIBILITY OF THE EOR AND NOT DETAILED. REFER TO OTHERS FOR WATER / MOISTURE PROOFING METHODS AND FIRE PROOFING DETAILS. 12.CONTRACTOR TO ENSURE THAT ALL DRAINAGE IS DIRECTED AWAY FROM THE EXTERIOR FOOTINGS (MIN. 2% SLOPE). ALL SOIL/GRADING RECOMMENDATIONS BY OTHERS. 13.THE EFFECTS OF FLOOD HAZARDS AND FLOOD LOADS HAVE NOT BEEN CONSIDERED BY THE EOR IN THE EXISTING DESIGN. 14.VIBRATION ANALYSIS HAS NOT BEEN CONSIDERED BY EOR. 15.GENERAL CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKMAN AND OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT TO BE LIMITED TO, BRACING, SHORING FOR CONSTRUCTION EQUIPMENT AND SHORING FOR THE STRUCTURE. FRAMING 1.ALL LUMBER USED FOR STRUCTURAL PURPOSES SHALL BE DOUGLAS FIR/LARCH CONFORM TO DOC PS20. ALL LUMBER SHALL BE LESS THAN 19% MOISTURE CONTENT FOR ALL CONSTRUCTION. CONTRACTOR SHALL MANAGE MOISTURE CONTENT TO EANSURE COMPATIBILITY. (EXCEPTION: ROOF TRUSSES MAY BE HEM-FIR OR SPRUCE PINE FIR) 2.LUMBER GRADES (U.N.O) 6X & 8X POSTS / BEAMS / HEADERS:DFL #1 4X POSTS / BEAMS / HEADERS:DFL #2 2X JOISTS / RAFTERS:DFL #2 STUDS:D.F.L. STUD GRADE (UP TO 9'-0"), DFL #2 (TALLER THAN 9'-0") TOP PLATES :DFL CONSTRUCTION GRADE OR BETTER MUD SILLS: DFL CONSTRUCTION GRADE OR BETTER 3.ALL SILL PLATES BEARING ON MASONRY OR CONCRETE FOUNDATION WALL OR SLAB ON GRADE SHALL BE PRESSURE TREATED IN ACCORDANCE WITH CBC 2304.12. SILL PLATES SHALL BE PRESERVATIVE TREATED WITH SODIUM BORATE (SBX/DOT) 4.ALL LUMBER EXPOSED TO THE WEATHER SHALL BE PRESSURE TREATED. 5.CONVENTIONAL LIGHT FRAMED CONSTRUCTION REQUIREMENTS OF CHAPTER 23 MUST BE FOLLOWED AS REQUIRED. 6.ALL THREAD ROD, THREAD STUDS, FOUNDATION ANCHOR BOLTS, MACHINE BOLTS SHALL CONFORM TO ASTM F1554-GR36. HOLES FOR BOLTS SHOULD BE DRILLED 1/16" LARGER THAN BOLT DIAMETER. ALL BOLTS SHALL BE INSTALLED WITH STEEL WASHERS AT FACE OF WOOD 7.ALL NAILS SHALL BE SINKER NAILS AND STAGGERED U.N.O., EXCEPT AS SHOWN IN NAILING SCHEDULE. 8.ADHESIVE USED TO ATTACH FLOOR SHEATHING TO FRAMING ELEMENTS SHALL CONFORM WITH APA SPECIFICATION AFG-01. 9.TYPICAL FLOOR/ROOF DECK/DECK SHEATHING: 23/32" APA RATED STURD-I-FLOOR T&G EXP I WITH MIN. SPAN RATING OF 24" O.C. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. B.N.:10d COMMON NAILS AT 6" O.C. E.N.:10d COMMON NAILS AT 6" O.C. F.N.:10d COMMON NAILS AT 12" O.C. USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 10.TYPICAL SLOPED/FLAT NON-ASSEMBLY ROOF SHEATHING: 15/32" APA RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. B.N. : 8d COMMON NAIL AT 6" O.C. E.N. : 8d COMMON NAIL AT 6" O.C. F.N. : 8d COMMON NAIL AT 12" O.C. *NOTE: ALL STRUCTURAL RATED PANELS MUST BE STAMPED BY ONE OF THE FOLLOWING APPROVED AGENCIES, APA, PFS/TECO OR PITTSBURG. 11.PROVIDE SINGLE JOISTS UNDER NON-BEARING PARTITION PARALLEL TO JOISTS. PROVIDE MINIMUM 2 FLOOR JOISTS BELOW BEARING WALLS UNLESS NOTED OTHERWISE ON PLANS. 12.FLOOR JOISTS ARE NOT DESIGNED TO SUPPORT WATER BEDS OR POOL TABLES. EOR TO BE NOTIFIED IF WATER BEDS OR POOL TABLES ARE TO BE USED. 13.STRUCTURAL MEMBERS SHALL NOT BE CUT OR NOTCHED UNLESS SPECIFICALLY DETAILED 14.ALL BEAMS TO BE SUPPORTED WITH FULL BEARING ON MULTI-STUD OR POST, U.N.O. 15.PROVIDE POST/MULTIPLE STUDS AT LOWER FLOOR UNDER POST/MULTIPLE STUDS ABOVE.PROVIDE FULL WIDTH AND DEPTH COMPRESSION BLOCK BETWEEN FLOORS AT SUCH LOCATIONS. 16.ALL FRAMING, BRACING, NAILING, NOTCHING, DRILLING OR BORING SHALL BE IN ACCORDANCE WITH BUILDING CODE UNLESS MORE STRINGENT REQUIREMENTS ARE SPECIFIED OR REQUIRED BY THE LOCAL JURISDICTION. 17.CONVENTIONAL LIGHT FRAMED CONSTRUCTION REQUIREMENTS OF CHAPTER 23 SHOULD BE FOLLOWED AS REQUIRED. 18.ALL FASTENERS IN CONTACT WITH PRESERVATIVE OR FIRE-TREATED WOOD SHALL BE HOT-DIPPED ZINC-COATED GALVANIZED WITH COATING WEIGHT PER ASTM A 153. 19.STRUCTURAL INFORMATION SHOWN ON FRAMING PLANS IS FOR THE MAIN STRUCTURAL ELEMENTS. NON-STRUCTURAL ELEMENTS SHALL BE CONSTRUCTED PER APPROVED CODE REQUIREMENTS. 20.ALL SHEAR PANELS SHALL HAVE CONTINUOUS SHEATHING MATERIAL FROM ONE END TO THE OTHER AND FROM PLATE TO PLATE AS SPECIFIED ON THE DRAWINGS. CONTRACTOR SHALL COORDINATE FRAMING SUCH THAT CONTINUITY OF SHEAR PANELS IS ASSURED. 21.ALL JOIST HANGERS SHALL BE SIMPSON U HANGER, ALL BEAM HANGERS SHALL BE SIMPSON HU HANGERS U.N.O. ON PLAN OR DETAIL. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION. 22.WALL FRAMING TO BE 2X STUDS AT 16 INCHES O.C. PROVIDE DOUBLE TOP PLATE ON ALL WALLS WITH MINIMUM 48 INCH LAP SPLICE, UNLESS SPECIFICALLY NOTED ON PLANS. 23.BUILDING CODE 2308.5.1 BALLOON FRAMED WALLS (NON-BEARING) STUD HEIGHTS: - 2X4'S @ 16" O.C. MAXIMUM 14'-0" HEIGHT - 2X6'S @ 16" O.C. MAXIMUM 20'-0" HEIGHT - NO MULTIPLES OF 2X4"S ARE ALLOWED TO SPAN MORE THAN 14'-0". BEARING WALLS EXCEEDING 10'-0" MUST BE DESIGNED CASE BY CASE. 24.HEADERS: USE 4X4 FOR OPENINGS LESS THAN 16" AT BEARING WALLS WITHOUT POINT LOADS. FOR NON-BEARING WALLS: - USE (2)2X4 FOR OPENINGS UP TO 6'-0" MAX. - USE 4X6 FOR OPENINGS UP TO 10'-0" MAX. U.N.O. 25.WITH DEAD LOAD = 6 PSF MAX. & LIVE LOAD = 10 PSF MAX., - 2X4 DF#2 CEILING JOISTS @ 16" O.C. WITH 9'-0" SPAN MAX. (U.N.O) - 2X6 DF#2 CEILING JOISTS @ 16" O.C. WITH 14'-0" SPAN MAX. (U.N.O) CONCRETE CONCRETE STRENGTH 1.ALL REINFORCED CONCRETE MATERIALS AND CONSTRUCTION SHALL CONFORM TO BUILDING CODE, CHAPTER 19. 2.CEMENT SHALL CONFORM TO SECTION 1903 OF BUILDING CODE AND SHALL CORRESPOND TO THAT ON WHICH THE SELECTION OF CONCRETE PROPORTIONS WERE BASED. 3.CONCRETE AGGREGATES SHALL CONFORM TO BUILDING CODE SECTION 1903. 4.PORTLAND CEMENT SHALL BE TYPE I OR II CONFORMING TO ASTM C150. FOR CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE SO4 ≥ 0.1% BY WEIGHT USE TYPE II CEMENT, CONTAINING SULFATE SO4 ≥ 0.2% BY WEIGHT USETYPE V CEMENT. WEIGHT PERCENTAGE OF SO4 SHALL BE PER SOILS REPORT. 5.REFER TO SECTION 1904 OF THE BUILDING CODE FOR SPECIAL EXPOSURE CONDITIONS AS REQUIRED BY SOILS ENGINEER & SEE CORROSION ENGINEER'S RECOMMENDATIONS FOR CONCRETE EXPOSED TO CORROSIVE ELEMENTS. 6.REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 FOR SIZES #3 AND GRADE 60 FOR SIZES #4 AND LARGER. 7.GROUT UNDER BASE PLATES SHALL BE NON-SHRINK TYPE AND SHALL HAVE COMPRESSIVE STRENGTH EQUAL TO OR GREATER THAN THE CONCRETE OR MASONRY SUPPORTING IT. 8.ALL GRADE BEAMS SHALL BE POURED MONOLITHICALLY FOR THEIR ENTIRE LENGTH. 9.ALL HORIZONTAL AND VERTICAL PIPING, CONDUITS, DUCTS OR OTHER OPENINGS IN/THROUGH ELEVATED OR ON GRADE SLABS SHALL BE INSTALLED PER THE MANUFACTURER INSTALLATION MANUAL AND MEET THE CLEARANCES & REQUIREMENTS EOR. AVOID ANY HORIZONTAL PIPING, CONDUITS, OPENINGS AND DUCTS, IN AREAS WITH CONGESTED REINFORCEMENT SUCH AS NEAR COLUMNS, COLUMN CAPS AND COLUMN STRIPS. VERTICAL PIPES, CONDUITS AND OTHER OPENINGS MAY BE ALLOWED AT THESE AREAS UPON VERIFICATION WITH STRUCTURAL ENGINEER OF RECORD. MORE REINFORCEMENT, CONCRETE AND/OR OTHER MEMBERS MAY BE ADDED TO MEET REQUIREMENTS IN SUCH CONDITIONS. 1.ALL REINFORCING, DOWELS, HOLDOWNS, AND OTHER INSERTS SHALL BE SECURED IN POSITION AND APPROVED BY THE LOCAL BUILDING OFFICIAL PRIOR TO THE POURING OF ANY CONCRETE. 2.CONCRETE SHALL BE PROPORTIONED TO PROVIDE A MINIMUM COMPRESSIVE STRENGTH, f'c, EQUAL TO 2500 PSI (28 DAYS) (U.N.O). 3.THE (28 DAYS) CONCRETE COMPRESSIVE STRENGTH, f'c, FOR CONCRETE IN CONTACT WITH SOIL WITH WEIGHT PERCENTAGE OF SULFATE (SO4) ≥ 0.10 SHALL BE 4000 PSI, AND WITH WEIGHT PERCENTAGE OF SULFATE (SO4) ≥ 0.20 SHALL BE 4500 PSI. SPECIAL INSPECTION IS NOT REQUIRED. 4.MIN. CONCRETE COVER FOR REINFORCING: - CONCRETE, PLACED AGAINST EARTH NOT FORMED - 3" - CONCRETE FORMED OR TROWELED - 2" - WALLS AND CURBS - 1 1/2" - SLAB ON GRADE - AT CENTER FOUNDATION 1.ALL FOOTINGS AND SLABS SHALL BE FOUNDED ON FIRM UNDISTURBED NATURAL SOILS OR COMPACTED FILL (SPECIFIED BY SOILS ENGINEER) MIN. 90% COMPACTION. 2.AN APPROVED VAPOR BARRIER MUST BE INSTALLED UNDER THE CONCRETE FOUNDATION SYSTEM SO THAT WATER AND VAPOR CANNOT ENTER INTO THE STRUCTURE.REFER TO ARCHITECT'S OR OWNER'S DOCUMENT AND SOILS ENGINEER'S RECOMMENDATIONS FOR DETAILED REQUIREMENTS. 3.THE SOILS ENGINEER SHALL INSPECT AND APPROVE ALL FOUNDATION TRENCH PRIOR TO PLACING REINFORCING AND/OR CONCRETE. 4.ALL CONTINUOUS FOOTINGS TO HAVE 5/8" DIA. X MIN. 12" ANCHOR BOLTS, MIN. 7" EMBEDMENT INTO CONCRETE FOOTING AT 72" O.C. UNLESS NOTED OTHERWISE ON PLANS. ALL BOLTS SHALL HAVE PROPERLY SIZED NUT AND WASHER. THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE SILL PLATE ON THE SIDE(S) WITH SHEATHING. MINIMUM 2 BOLTS OR ANCHOR STRAPS PER PIECE OF SILL PLATE WITH ONE BOLT OR ANCHOR STRAP LOCATED NOT MORE THAN 12" OR LESS THAN 4" FROM EACH END OF EACH PIECE. 5.ANCHOR BOLTS AT SHEAR WALLS SHALL BE INSTALLED WITH PLATE WASHERS OF MIN. 3" SQ. X 0.229" THICK BETWEEN SILL PLATE AND NUT. 6.THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16 INCH LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXEED 1 3/4 INCHES, PROVIDED A STANDARD CUT WASHER ( 5/8" NOMINAL SIZE : 11/16" ID,1 3/4" OD , 9/64" THICK ) IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. 7.FOR INTERIOR NON-SHEAR WALLS USE SIMPSON PDPAWL-MG SERIES 0.157Ø PINS WITH A PENETRATION OF 1 1/4" INTO SLAB AT 16" O.C. TO BE INSTALLED IN ACCORDANCE WITH ICC ESR-2138. ACTUAL SLAB THICKNESS TO BE MINIMUM 4". 8.ALL HOLDOWNS AND POST ANCHORS TO BE INSTALLED ACCORDING TO MOST CURRENT SIMPSON STRONG TIE SPECIFICATIONS AND REQUIREMENTS OF ICC-ER REPORTS & SHALL BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. DIMENSIONS ARE NOT FURNISHED TO SIMPSON HOLDOWNS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR'S SUPERINTENDENT, THE FRAMING CONTRACTOR AND THE CONCRETE CONTRACTOR TO LOCATE THESE ANCHORS IN THE EXACT LOCATION. REFER TO DETAILS FOR PROPER INSTALLATION. 9.PROVIDE MIN. (1) #4 REINFORCING FOR ELECTRICAL GROUND, LOCATION TO BE VERIFIED WITH THE ELECTRICAL CONTRACTOR. 10.PROVIDE #3 X 24" DOWEL AT 24" O.C. AND 12" FROM THE CORNER AT ALL CONCRETE STOOPS AND PORCHES. 11.CONCRETE SHALL BE TO THE STRENGTH AND SLUMP AS SPECIFIED PER STRUCTURAL DESIGN, AND CONSIST OF PORTLAND CEMENT ASTM C-150 TYPE V PER SOILS ENGINEER'S RECOMMENDATIONS AND BUILDING CODE SECTION 1904.1 (ACI 318 SECTION 19.3) WHEN EXPOSED TO SULFATE CONTAINING SOLUTIONS. AGGREGATES SHALL BE PER ASTM C-33. WATER TO BE CLEAN AND POTABLE. 12.CONCRETE PLACEMENT SHALL BE MONOLITHIC IN ONE CONTINUOUS OPERATION UNIFORMLY PLACED AND MUST BE VIBRATED AND WELL CONSOLIDATED UNLESS SHOWN OTHERWISE ON PLANS. 13.NO PIPES OR CONDUITS SHALL EXTEND UNDER ISOLATED COLUMN FOOTING OR UNDER CONTINUOUS WALL FOOTINGS UNLESS SPECIFICALLY DETAILED OR APPROVED BY THE ARCHITECT, STRUCTURAL ENGINEER AND THE BUILDING OFFICIAL. 14.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING NECESSARY TO SUPPORT CUT AND/OR FILL SECTIONS DURING EXCAVATION, AND FOR FORMING AND PLACEMENT OF CONCRETE. BASIS FOR DESIGN BUILDING CODE: 1.CBC 2022 LATERAL LOADS: S1 = SD1 = 3. = 20 psf DESIGN LOADS: ROOF LL 4. Ss = SDs = ROOF DL = 20 psf SEISMIC DESIGN CATEGORY: SITE CLASS: SEISMIC IMPORTANT FACTOR (I) = 1 WIND SPEED = WIND EXPOSURE : 95 MPH C D 1.294 1.036 0.464 0.568 D - DEFAULT Fa = Fv = 1.20 1.84 = 15 psf FLOOR LL FLOOR DL = 40 psf 2. THE FOUNDATION DESIGN IS BASED UPON THE MINIMUM PRESUMPTIVE LOAD-BEARING VALUES PER 2022 CBC TABLE 1806.2. ALLOWABLE SOIL BEARING PRESSURE OF 1500 PSF IS USED. IF THE BUILDING INSPECTOR SUSPECTS FILL, EXPANSIVE SOILS OR ANY GEOLOGIC INSTABILITY BASED UPON OF THE FOUNDATION EXCAVATION, A SOILS OR GEOLOGICAL REPORT, AND RESUBMITTAL OF PLANS TO PLAN CHECK TO VERIFY THAT REPORT RECOMMENDATIONS HAVE BEEN INCORPORATED, MAYBE REQUIRED. SOILS: ABBREVIATION A.B.ANCHOR BOLT BOTT.BOTTOM B.N.BOUNDARY NAILING P.T.POST TENSION E.N.EDGE NAILING F.H.FULL HEIGHT F.N.FIELD NAILING TYP.TYPICAL SIMP.SIMPSON SIM.SIMILAR MFR.MANUFACTURER O.C.ON CENTER M.B.MACHINE BOLT REINF.REINFORCEMENT (E)EXISTING FL BM FLUSH BEAM HD HOLDOWN DR BM DROP BEAM P.T.D.F PRESSURE TREATED DOUGLAS FIR HDR HEADER EXT.EXTERIOR G.T.GIRDER TRUSS INT.INTERIOR BLK'G BLOCKING U.N.O.UNLESS NOTED OTHERWISE W/WITH VERT.VERTICAL CONT.CONTINUOUS HORZ.HORIZONTAL CANT.CANTILEVER SHT'G SHEATHING REQ'D REQUIRED ALT.ALTERNATE COND.CONDITION DBL.DOUBLE DIA.DIAMETER EA.EACH STD.STANDARD CONC.CONCRETE C'SINK COUNTER SINK ABV.ABOVE T&G TONGUE AND GROOVE V.I.F VERIFY IN THE FIELD DESCRIPTION OF BUILDING ELEMENTS NUMBER & TYPE OF FASTENER SPACING & LOCATION 1.BLOCKING BETWEEN CEILING JOISTS, RAFTERS OR TRUSSES TO TOP PLATE OR OTHER FRAMING BELOW 4-8d BOX (2 1/2"X0.113") 3-8d COMMON (2 1/2"X0.131") 3-10d BOX (3″ × 0.128″) END NAIL BLOCKING BETWEEN RAFTERS OR TRUSS NOT AT THE WALL TOP PLATE, TO RAFTER OR TRUSS FACE NAIL FACE NAIL PER TABLE 2308.7.3.1 FACE NAIL 3-10d COMMON (3" × 0.148") 4-10d BOX (3" × 0.128")FACE NAIL 3-10d COMMON (3"X0.148") 4-16d BOX (3 1/2"X0.135") 4-10d BOX (3" × 0.128") TOENAIL 3-16d BOX (3 1/2"X0.135") 3-10d BOX (3" × 0.128")END NAIL 10d BOX (3" × 0.128") 16d COMMON (3 1/2"X0.162") 16d BOX (3 1/2"X0.135") 16d COMMON (3 1/2"X0.162") 16d BOX (3 1/2"X0.135") 4-8d COMMON (2 1/2"X0.131") TOENAIL 8-16d COMMON (3 1/2"X0.162") 12" O.C. FACE NAIL TOENAIL END NAIL FACE NAIL 16" O.C. FACE NAIL 16" O.C. FACE NAIL WALL FACE NAIL FACE NAIL FACE NAIL FLOOR TOENAIL 6" O.C., TOENAIL BLIND AND FACE NAIL 16d COMMON (3 1/2"X0.162") FACE NAIL 2.CEILING JOISTS TO TOP PLATE 3.CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAP OVER PARTITIONS (NO THRUST) (SEE SECTION 2308.7.3.1, TABLE 2308.7.3.1) 4.CEILING JOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT) (SEE SECTION 2308.7.3.1, TABLE 2308.7.3.1) 5.COLLAR TIE TO RAFTER 6.RAFTER OR ROOF TRUSS TO TOP PLATE (SEE SECTION 2308.7.5, TABLE 2308.7.5) 7.ROOF RAFTERS TO RIDGE VALLEY OR HIP RAFTERS ROOF RAFTER TO 2-INCH RIDGE BEAM 8.STUD TO STUD (NOT AT BRACED WALL PANELS) 9.STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS (AT BRACED WALL PANELS) 10.BUILT-UP HEADER (2″ TO 2″ HEADER) 11.CONTINUOUS HEADER TO STUD 12.TOP PLATE TO TOP PLATE 13.TOP PLATE TO TOP PLATE, AT END JOINTS 14.BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) 15.BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING AT BRACED WALL PANELS 16.STUD TO TOP OR BOTTOM PLATE 17.TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS 18.1″ BRACE TO EACH STUD AND PLATE 19.1″ × 6″ SHEATHING TO EACH BEARING 20.1″ × 8″ AND WIDER SHEATHING TO EACH BEARING 21.JOIST TO SILL, TOP PLATE, OR GIRDER 22.RIM JOIST, BAND JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER FRAMING BELOW 23.1"X6" SUBFLOOR OR LESS TO EACH JOIST 24.2″ SUBFLOOR TO JOIST OR GIRDER 25.2″ PLANKS (PLANK & BEAM –FLOOR & ROOF) 26.BUILT-UP GIRDERS AND BEAMS, 2″ LUMBER LAYERS 27.LEDGER STRIP SUPPORTING JOISTS OR RAFTERS 28.JOIST TO BAND JOIST OR RIM JOIST 29.BRIDGING OR BLOCKING TO JOIST, RAFTER OR TRUSS 2-8d COMMON (2 1/2" X 0.131") 2-16d COMMON (3 1/2" X 0.162") FLAT BLOCKING TO TRUSS AND WEB FILLER 16d COMMON (3 1/2"X0.162") 6"O.C. 3-16d COMMON (3 1/2"X0.162") 4-10d BOX (3″ × 0.128″) 4-8d BOX (2 1/2"X0.113") 3-8d COMMON (2 1/2"X0.131") 3-10d BOX (3″ × 0.128″) EACH JOIST, TOENAIL EACH END, TOENAIL EACH END, TOENAIL 3-10 COMMON (3″ X 0.148″) 3-16d BOX (3 1/2" X 0.135") 4-10d BOX (3" × 0.128″) 2 TOENAIL ON ONE SIDE AND 1 TOE NAIL ON OPPOSITE SIDE OF RAFTER OR TRUSS(1) 16d COMMON (3 1/2″ × 0.162″) 16″ O.C. EA. EDGE, FACE NAIL 12″ O.C. EA. EDGE, FACE NAIL EACH SIDE OF END JOINT, FACE NAIL (MIN. 24" LAP SPLICE LENGTH EACH SIDE OF END JOINT) EACH BEARING, FACE NAIL 24" O.C., FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES EACH JOIST OR RAFTER, FACE NAIL END NAIL EACH END, TOENAIL ROOF 2-16d COMMON (3 1/2"X0.162") WIDER THAN 1" x 8" 4" O.C., TOENAIL AND:ENDS AND AT EACH SPLICE, FACE NAIL (1)WHERE A RAFTER IS FASTENED TO AN ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS SCHEDULE AND THE CEILING JOIST IS FASTENED TO THE TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE, THE NUMBER OF TOENAILS IN THE RAFTER SHALL BE PERMITTED TO BE REDUCED BY ONE NAIL. (2)FOR OTHER TYPE OF FASTENER AND BUILDING ELEMENTS SEE TABLE 2304.10.2 OF CBC 2022. (3)NO STAPLE ALLOWED 4-10d BOX (3″ × 0.128″) 5-8d BOX (3″ × 0.113″) 10d BOX (3″ × 0.128″) 12-16d BOX (3 1/2″ × 0.135″) 12-10d BOX (3″ × 0.128″) 16d COMMON (3 1/2″ × 0.162″) 16d BOX (3 1/2″ × 0.135″) 2-16d COMMON (3 1/2″ × 0.162″) 3-16d BOX (3 1/2″ × 0.135″) 3-16d BOX (3 1/2″ × 0.135″) 4-8d COMMON (2 1/2″ × 0.131″) 4-10d BOX (3″ × 0.128″) 2-16d COMMON (3 1/2″ × 0.162″) 3-16d BOX (3 1/2″ × 0.135″) 3-10d BOX (3″ × 0.128″) 2-16d COMMON (3 1/2″ × 0.162″) 3-10d BOX (3″ × 0.128″) 3-8d BOX (2 1/2″ × 0.113″) 2-8d COMMON (2 1/2″ × 0.131″) 2-10d BOX (3″ × 0.128″) 3-8d BOX (2 1/2″ × 0.113″) 2-8d COMMON (2 1/2″ × 0.131″) 2-10d BOX (3″ × 0.128″) 3-8d COMMON (2 1/2″ × 0.131″) 3-8d BOX (2 1/2″ × 0.113″) 3-10d BOX (3″ × 0.128″) 3-8d COMMON (2 1/2″ × 0.131″) 4-8d BOX (2 1/2″ × 0.113″) 3-10d BOX (3″ × 0.128″) 4-8d BOX (2 1/2″ × 0.113″) 3-8d COMMON (2 1/2″ × 0.131″) 3-10d BOX (3″ × 0.128″) 8d BOX (2 1/2″ × 0.113″) 8d COMMON (2 1/2″ × 0.131″) 10d BOX (3″ × 0.128″) 3-8d BOX (2 1/2″ × 0.113″) 2-8d COMMON (2 1/2″ × 0.131″) 2-10d BOX (3″ × 0.128″) 3-16d BOX (3 1/2″ × 0.135″) 2-16d COMMON (3 1/2″ × 0.162″) 3-16d BOX (3 1/2″ × 0.135″) 2-16d COMMON (3 1/2″ × 0.162″) 10d BOX (3″ × 0.128″) 3-10d BOX (3″ × 0.128″) 3-16d COMMON (3 1/2″ × 0.162″) 4-16d BOX (3 1/2″ × 0.135″) 4-10d BOX (3″ × 0.128″) 3-16d COMMON (3 1/2″ × 0.162″) 4-10d BOX (3″ × 0.128″) 2-8d COMMON (2 1/2″ × 0.131″) 2-10d BOX (3″ × 0.128″) 12″ O.C. FACE NAIL 16″ O.C. FACE NAIL 16″ O.C. FACE NAIL 24″ O.C. FACE NAIL 16″ O.C. FACE NAIL 12″ O.C. FACE NAIL S0 STRUCTURAL GENERAL NOTES & REQUIREMENTS & TYPICAL DETAILS 1/2" MAX. 1/2" MAX. EQ. SHEAR PANEL WHERE OCCURS PLATE WASHER 2"EQ. 2x4 SHEAR WALLS SHEAR WALLS OF 2x6 AND THICKER WALLS 1/2" MAX. PLATE WASHER SW ANCHOR BOLTS DETAIL BEND D= 10(d) FOR #14 THRU #18 OFFSET & SPLICES WIRE TIE END 48(d) MASONRY (U.N.O.) 48(d) * IN CONCRETE 90° BEND D= 8(d) FOR #9 THRU #11 D= 6(d) FOR #3 THRU #8 2 1/2" MIN.8(d) 180° BEND12 d 4(d) OR * INCREASE LENGTH BY 30% FOR TOP BARS (HORIZONTAL BARS SO PLACED THAT MORE THAN 12 INCHES OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW, EXCLUDE WALLS) - ALL BENDS SHALL BE MADE COLD 6 1 MADE COLD - ALL BENDS SHALL BE STIRRUP ALT. 135° BENDS - PUT CROSSTIE W/ EACH D= 4(d) FOR #3 THRU #5 D= 6(d) FOR #6 THRU #8 4" M I N . 12 ( d ) F O R # 6 T H R U # 8 NOTES: STIRRUPS & TIES 3" M I N . 6( d ) F O R # 3 T H R U # 6 12( d ) F O R # 6 T H R U # 8 6(d ) F O R # 3 T H R U # 6 "D" "D" PRINCIPAL REINFORCEMENT MIN. BEND DIA. (STIRUPS & TIES) #3 D #4 1 1/2" #5 2" #6 2 1/2" BAR 4 1/2" TYP. REINFORCING DETAILS 1/8" 3/8" MIN. 1/4" 1 2 3 4 5 1.DOUBLE TOP PLATE W/E.N. 2.TYP. 2X STUD @ 16" O.C. W/F.N. 3.2X FLAT BLK'G @ SHEAR WALL PLYWOOD SPLICED W/ E.N. 4.SILL PLATE W/ E.N. 5.SHEAR WALL PER PLAN 24 " M I N . 6 7 6.HOLDOWN WHERE OCCURS 7.FOUNDATION STRAP PER PLAN. LOCATED STRAP OVER PLYWOOD SHEAR PANEL & PROVIDE SHIM AS NECESSARY TO AVOID BENDING STRAP. SEE MANUF. RECOMMENDATIONS TO AVOID BOWING WHEN INSTALLING FLOOR-TO-FLOOR STRAP. 8 8.SIMPSON A35, LS50 PER SHEAR WALL SCHEDULE SHEATHING. -SEE SW SCHEDULE FOR PLYWOOD TYPE, THICKNESS, SPACING, & NAIL SIZE. -PROVIDE MIN. 3/8" EDGE DISTANCE @ FRAMING MEMBER & 5/16" TO EDGE OF PLYWOOD SHEAR WALL. NOTES: -STAGGERED JOINTS AS SHOWN -NAILS SHALL BE DRIVEN TIGHT BUT SHALL NOT FRACTURE SURFACE OF TYPICAL SHEAWALL LAYOUT 9 9.END POST W/E.N., IF MULTIPLE STUDS ARE USED, APPLYING E.N. TO ALL STUDS DESCRIPTIONDATENO. REVISIONS PLOT DATE:05/07/2026 ENGINEER:TH 23 1 4 W . S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 RE M O D E L PROJECT NO.:30424 DATE SIGNED: 5/7/26 SHEET NAME: TITLE BLOCK CONSULTANT THANH HUYNH (949) 466-7857 PLAN CHECK01/14/261 PLAN CHECK05/07/262 ROOF SHEATHING ROOF SHEATHING PARALLEL ROOF CONDITION P.T.D.F SILL PLATE WITH ANCHOR BOLT, SEE FOUNDATION PLAN FOR SIZE AND SPACING BLK'G. (2X, I-JOIST) MIN. 12" LONG @ MAX. 48" O.C. WITH FLOOR E.N. SECURE W/ (2) 16d'S E/S. PROVIDE SOLID BLOCKING OR CONT. RIM JOIST AT ALL BEARING POINTS CODE APPROVED SHOT PINS, SEE FOUNDATION NOTES TYPICAL FRAMING CROSS SECTION 1 ALT. CONDITION 1/8" GAP ROOF OR FLOOR SHEATHING. PANEL JOINT. 4 16" MIN. OFFSET EDGE SUPPORT 1/ 8 " 1/8" SHEATHING LAYOUT 5 4 1 3 1/8" GAP 2 3 2X4 W/ NAILS TO BE MATCHED W/ EDGE NAILING. 4 ROOF OR FLOOR FRAMING MEMBER. 2X4 BLK'G 6'-0" LONG MAX W/ (2) 16d COMMON NAILS @ EA. END.5 FIELD NAILING PER PLAN. PANEL EDGE WHERE 2X FLAT BLKG. IS NEEDED @ BLOCKED DIAPHRAGM.6 DIAPHRAGM BOUNDARY & B.N. PER PLAN.7 DISCONTINUOUS PANEL EDGE, EDGE NAILING PER PLAN.8 9 10 24" MIN. UNLESS FULLY BLOCKED @ ALL EDGES. NOTES: - STAGGERED JOINTS AS SHOWN - NAILS SHALL BE DRIVEN TIGHT BUT SHALL NOT FRACTURE SURFACE OF SHEATHING. - PROVIDE MIN. 3/8" EDGE DISTANCE @ FRAMING MEMBER & 5/16" TO EDGE OF PLYWOOD DIAPHRAGM. - ALL DIAPHRAGM BOUNDARIES SHOULD BE FULLY SUPPORTED BY FRAMING MEMBERS W/ BOUNDARY NAILING - T&G EDGE TO BE LOCATED OVER CONTINUOUS PANEL JOINT. - MAX. UNSUPPORTED SHEATHING TO BE 24". PROVIDE ADEQUATE FRAMING MEMBERS TO LIMIT SPAN. 10 6 4 6 7 8 10 9 1 2 2 SYMBOLS LEGEND SX X EXISTING FOOTING NEW FOOTING X X'-X" FRAMING NOTES INDICATES POST OR TRIMMER, SIZE AS NOTED ON PLAN BEAM NUMBER, REFER TO CALCULATIONS DIRECTION OF ROOF TRUSS/ RAFTER DIRECTION OF 2X MEMBERS/ I-JOIST FLOOR JOIST BEARING WALL FOUNDATION NOTES DIRECTION OF 2X MEMBERS/ DECK JOIST INDICATES ISOLATE PAD FOOTING, REFER TO PAD SCHEDULE FOR SIZE AND REINFORCEMENT TOTAL MINIMUM NUMBER OF ANCHOR BOLTS EQUALLY SPACED AS POSSIBLE. DETAIL NUMBER DETAIL SHEET NUMBER P# #INDICATES HOLDOWN LOCATION, REFER TO HOLDOWN SCHEDULE FOR SIZE AND BOLT TYPE, REFER TO DETAIL 3/SD1 FOR HOLDOWN DETAIL # 1.REFER TO STRUCTURAL GENERAL NOTES AND REQUIREMENTS (SHEET S0) FOR MORE INFORMATION. 2.APPLY SHEAR PRIOR TO FRAMING OF PERPENDICULAR WALLS. DO NOT BREAK SHEAR AT PERPENDICULAR WALL LOCATIONS. 3.SHEAR PANEL CAN BE APPLIED EITHER SIDE OF THE STUD. 4.WHEN MULTIPLE STUD ARE USED INSTEAD OF SINGLE POST, PLYWOOD SHEAR WALL TO BE NAILED TO ALL STUDS RECEIVING STRAP/ HOLDOWNS. 5.ALL BEAMS SHOWN ARE DROP (U.N.O.) ON PLANS. 6.HEADERS SHALL HAVE AT LEAST ONE 2X TRIMMER W/ ONE 2X KING STUD CONTINUOUS TO THE SILL PLATE W/ 16d's @ 24" O.C. (U.N.O.). 7.HEADERS SPANNING 6'-0" OR MORE SHALL HAVE AT LEAST 2-2X TRIMMERS CONTINUOUS TO THE SILL PLATE AND 2-2X KING STUDS, (U.N.O.). 8.ALL SHEAR CONNECTORS AND BLOCKING AT PLATE LEVEL MUST BE INSTALLED PRIOR TO THE INSTALLATION OF FLOOR / ROOF SHEATHING. 9.MANUFACTURED HARDWARE SPECIFIED ON THE DRAWINGS ARE TO BE SIMPSON STRONG TIE. FOLLOW ALL MANUFACTURER'S REQUIREMENTS & RECOMMENDATIONS FOR INSTALLATION & HANDLING OF THE PRODUCT. 10.FOR ALL CS COILED STRAPS USE 8d NAILS ON EVERY OTHER NAIL HOLE. (U.N.O) 11.ALL JOIST HANGERS SHALL BE "U" HANGER, ALL BEAM HANGERS SHALL BE "HU" HANGER (U.N.O). FILL BOTH TRIANGLE AND ROUND HOLES OF HANGER 12.SIMPSON LTP5 CONNECTOR MAY BE USED IN PLACE OF SIMPSON A35. 13.TOP PLATES AT ALL LEVELS SHOULD BE SPLICED WITH A ST22 U.N.O. ON PLANS. 14.CONTINUOUS 1 1/4” LSL RIM JOISTS SHOULD BE USED AT ALL FLOOR FRAMING EDGES WHERE POSSIBLE. ALL RIM BREAKS SHOULD BE SPLICED WITH A SINGLE CS16 X36" STRAP U.NO. ON PLANS. 15.STRUCTURAL COMPOSITE LUMBER PARALLAM - PSL 2.2E FB = 2900 PSI, FV = 285 PSI, E = 2200 KSI TIMBERSTRAND - LSL 1.55E FB = 2325 PSI, FV = 310 PSI, E = 1550 KSI ////INDICATES SHEAR WALL APPLIED TO WALL SHEAR PANEL LENGTH AND NUMBER. REFER TO SHEAR WALL SCHEDULE FOR PANEL TYPE AND NAILING X CONSTRUCTION NOTES 1.REFER TO STRUCTURAL GENERAL NOTES AND REQUIREMENTS (SHEET S0) FOR MORE INFORMATION. 2.THE FOUNDATION DESIGN IS BASED UPON THE MINIMUM PRESUMPTIVE LOAD-BEARING VALUES PER 2022 CBC TABLE 1806.2. ALLOWABLE SOIL BEARING PRESSURE OF 1500 psf IS USED. 3.ALL FOOTINGS AND SLABS SHALL BE FOUNDED ON FIRM UNDISTURBED NATURAL SOILS OR COMPACTED FILL (SPECIFIED BY SOILS ENGINEER) MIN. 90% COMPACTION. 4.IF THE BUILDING INSPECTOR SUSPECTS FILL, EXPANSIVE SOILS OR ANY GEOLOGIC INSTABILITY BASED UPON OF THE FOUNDATION EXCAVATION, A SOILS OR GEOLOGICAL REPORT, AND RESUBMIT OF PLANS TO PLAN CHECK TO VERIFY THAT REPORT RECOMMENDATIONS HAVE BEEN INCORPORATED, MAYBE REQUIRED. 1.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS, CONDITIONS AT THE JOB SITE, AND TO CROSS CHECK ALL DETAILS AND DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS WITH RELATED REQUIREMENTS ON THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND/OR CIVIL DRAWINGS AND NOTIFY THE ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO STARTING WORK. 2.IN ALL CASES WHERE A CONFLICT MAY OCCUR SUCH AS BETWEEN ITEMS INCLUDED IN THE SPECIFICATIONS AND NOTES ON THE DRAWINGS OR BETWEEN GENERAL NOTES AND SPECIFIC DETAILS, THE ENGINEER SHALL BE NOTIFIED AND HE WILL INTERPRET THE INTENT OF THE CONTRACT DOCUMENT. 3.DETAIL MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. 4.FOR ANY PRE-MANUFACTURED PRODUCTS OR MATERIALS OF CONSTRUCTION, CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH AND FOR PROPER EXECUTION OF MANUFACTURER'S INSTRUCTIONS, REQUIREMENTS AND CONDITIONS OF APPROVAL PRIOR TO INSTALLATION AND/OR USE. 5.WOOD FRAMING MEMBERS (INCLUDING WOOD SHEATHING) LESS THAN 8 INCHES FROM EXPOSED EARTH SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. 6.CONTRACTOR TO ENSURE THAT ALL DRAINAGE IS DIRECTED AWAY FROM THE EXTERIOR FOOTINGS (MIN. 2% SLOPE). ALL SOIL/GRADING RECOMMENDATIONS BY OTHERS. 7.GENERAL CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKMAN AND OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT TO BE LIMITED TO, BRACING, SHORING FOR CONSTRUCTION EQUIPMENT AND SHORING FOR THE STRUCTURE 8.ALL INFORMATION SHOW ON THE PLAN RELATIVE TO EXISTING CONDITION WERE CAREFULLY TAKEN WITHOUT GUARANTEE OF ACCURACY. CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING CONDITION THAT IS REQUIRED TO VERIFY IN THE FIELD (V.I.F.). WHERE ACTUAL CONDITIONS ARE IN CONFLICT WITH THE PLAN, THEY SHALL BE REPORTED TO THE ENGINEER OF RECORD AND ARCHITECT SO THAT PROPER CHANGES CAN BE MADE. 9.DO NOT REMOVE ANY EXISTING STRUCTURE ELEMENT WITHOUT CONSULT WITH E.O.R BY WRITING 10.THE EXISTING FRAMING IS SHOWN FOR REFERENCE ONLY. THE E.O.R. HAVE NO RESPONSIBLE FOR THE DESIGN OF THE EXISTING STRUCTURAL ELEMENT MARKED AS "EXISTING" OR "(E)". WH W/D DW EXISTING CONCRETE SLAB EXISTING CONCRETE SLAB EXISTING CONCRETE SLAB EXISTING FOOTING EXISTING FOOTING EXISTING FOOTING MIN. 15"X18", V.I.F. EXISTING FOOTING MIN. 15"X18", V.I.F. THE CONTRACTOR SHALL PROVIDE THE ADEQUATE SUPPORT AND/ OR SHORING FOR EXISTING STRUCTURAL ELEMENT PRIOR TO CONSTRUCTION 2'-6" SQ. X 12" DEEP CONC. PAD W/ (4) #4 @ BOTTOM. E.W. BELOW THE EXISTING FTG. 2'-6" SQ. X 12" DEEP CONC. PAD W/ (4) #4 @ BOTTOM. E.W. BELOW THE EXISTING FTG. EXISTING FOOTING 1 SD1 1 SD1 3 SD1 2 SD1 TYP. 3 SD1 1 WH W/D DW (E ) (E) (E) (E)(E)(E)(E) (E ) (E ) (E ) THE CONTRACTOR SHALL PROVIDE THE ADEQUATE SUPPORT AND/ OR SHORING FOR EXISTING STRUCTURAL ELEMENT PRIOR TO CONSTRUCTION 4X4 6 SD1 5 1 / 4 " X 1 8 " 2 . 2 E P S L 1 4X 6 4X6 4 SD1 4 SD1 5 SD1 NEW 2X ROOF RAFTER SAME SIZE W/ EXISTING ATTACHED TO (E) ROOF RAFTER PER DETAIL 6/SD1 7 SD1 1 EXISTING ROOF RAFTER 4X4 1 8 SD1 2 (E ) 6 SD1 5 1 / 4 " X 1 8 " 2 . 2 E P S L 1 4X 6 4X6 4 SD1 4 SD1 5 SD1 NEW 2X ROOF RAFTER SAME SIZE W/ EXISTING ATTACHED TO (E) ROOF RAFTER PER DETAIL 6/SD1 7 SD1 1 EXISTING ROOF RAFTER S1 & FRAMING PLAN FOUNDATION PLAN DESCRIPTIONDATENO. REVISIONS PLOT DATE:05/07/2026 ENGINEER:TH 23 1 4 W . S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 RE M O D E L PROJECT NO.:30424 DATE SIGNED: 5/7/26 SHEET NAME: TITLE BLOCK CONSULTANT THANH HUYNH (949) 466-7857 PLAN CHECK01/14/261 PLAN CHECK05/07/262 1/4"=1'-0" SCALEFOUNDATION PLAN 1/4"=1'-0" SCALE2ND FLOOR FRAMING PLAN1/4"=1'-0" SCALEROOF FRAMING PLAN (FOR REFERENCE ONLY) DESCRIPTIONDATENO. REVISIONS PLOT DATE:05/07/2026 ENGINEER:TH 23 1 4 W . S A N L O R E N Z O SA N T A A N A , C A 9 2 7 0 4 RE M O D E L PROJECT NO.:30424 DATE SIGNED: 5/7/26 SHEET NAME: TITLE BLOCK CONSULTANT THANH HUYNH (949) 466-7857 PLAN CHECK01/14/261 PLAN CHECK05/07/262 SD1 STRUCTURAL DETAILS 1 2 3 4 5 6 7 8 ADD PAD AT EXTERIOR FOOTING ADD PAD PT EXT 1 POST PER PLAN 2 INTERIOR FINISH. 3 P.T.D.F SILL PLATE 4 EXISTING CONC. SLAB AND FOOTING 5 REINFORCEMENT, SEE PLAN 8" 18" 6 MIN. 5" EMBEDMENT OF DOWELS INTO EXISTING CONCRETE W/ SIMPSON SET-3G EPOXY, ESR #4057. 7 #4 DOWELS @ 18" O.C. BENT AS SHOWN (MIN. TWO DOWELS) NOTES: - CONCTRACTOR SHALL SPECIFY OVERALL LENGTH OF THE DOWELS. 8" MI N . 3" CL R SEE PLAN 24 " M I N . 12 " M I N . ℄ 3" CLR. 1 2 3 4 6 5 7 (U . N . O ) (U . N . O ) 3" CL R . 6" MI N . 1 TYP. 2X STUD AT NON-BEARING AND NON SHEAR WALL 2 SIMPSON PDPAW -MG 0.157Ø PINS WITH PENETRATION OF 1 1/4" INTO SLAB @ 16" O.C. TO BE INSTALLED IN ACCORDANCE WITH ICC ESR-2138 3 CONCRETE SLAB, SEE DETAIL #1 FOR MORE INFORMATION FN008 - SEE DETAIL #1 FOR LEGEND AND INFORMATION NOT SHOWN. NOTES: 1 1 1 / 4 " 2 3 TYPICAL NON SHEAR WALL AND NON-BEARNIG INTERIOR WALL 1 2 3 CONNECTION DETAIL SPE 4X4 POST 3' - 6 " M A X . TYP. 2X STUD @ 16" O.C. 2X P.T.D.F SILL PLATE W/ , SEE FOUNDATION NOTE FOR MORE INFORMATION 2 3 1 4 4 RCKW3S W/ 1/2" DIA. x 4" LONG STRONG-BOLT 2 WEDGE ANCHOR 5 5 CONTINUOUS DOUBLE TOP PLATE 6 6 SIMPSON BC4 POST & BEAM CONNECTION D124 1 POST PER PLAN 2 BEAM PER PLAN 3 SIMPSON ST6224 (U.N.O) 4 SIMPSON CC, CCQ (U.N.O) 2 1 3 4 5 5 SIMPSON ECC, ECCQ (U.N.O) 6 PROVIDE SOLID BLK'G AS REQ'D 6 3 2 4 22 ROOF RAFTER TO DROP BEAM SPE 1 BEAM PER PLAN 2 ROOF SHEATHING PER PLAN 3 2X BEVELED BLK'G W/ E.N. 4 EXISTING ROOF RAFTER PER PLAN 5 BEVELED BEARING PLATE W/16d @ 6" O.C., DO NOT CUT THE ROOF RAFTER 1 2 3 4 PLATELINE 6 6 SIMPSON H2.5A AT EACH ROOF RAFTER TO BEAM 5 7 SIMPSON LTP4 OR A35 @ EVERY BLOCKING TO BEAM A A PLATE LINE PL A T E L I N E PLATE LINE PL A T E L I N E PLATELINE PLATELINE PLATELINE SECTION A-A 2 1 3 7 76 4 CONNECTION DETAIL X 1 2 3 4 NEW DROP BEAM, SEE DETAIL #5 FOR CONNECTION EXISTING DOUBLE TOP PLATE EXISTING 2X STUD @ 16" O.C. EXISTING ROOF DIAPHRAGM PER PLAN 5 EXISTING BEVELED BLOCKING W/ B.N. 6 (3) 16d AT EACH END OF NEW ROOF RAFTER TO EXISTING ROOF RAFTER 16" 16" A A 1 2 3 5 6 SECTION A-A 1 4 6 7 7 TWO ROWS OF 16d @ 16" O.C. STAGG. 7 89 89 8 EXISTING 2X ROOF RAFTER 9 NEW 2X ROOF RAFTER SAME SIZE AS THE EXISTING ATTACHED TO THE EXISTING W/(2) ROWS OF 16d @ 16" O.C. STAGG. EXTENDED MIN. 4" FROM THE NEW DROP BEAM. 7 4" NOTES: ATTACHING A NEW ROOF RAFTER TO AN EXISTING RAFTER THAT WAS NOTCHED AT THE BOTTOM ONLY - 10 10 EXISTING NOTCHED 11 SIMPSON H2.5A AT EACH ROOF RAFTER TO BEAM 11 12 SIMPSON A35 @ EVERY BLOCKING TO BEAM 12 DRAG DETAIL D123 1 2 3 4 5 EQUAL EQUAL EQUALEQUAL TRIMMER PER PLAN HEADER PER PLAN. DBL. TOP PLATE TYP. STUD @ 16" O.C. SIMP. ST6236 STRAP U.N.O. CENTERED FROM PLATE TO PLATE/HEADER. 2x KING STUD (U.N.O.) W/16d's @ 24" O.C. 6 1 6 5 6 5 2 1 3 465 2 1 1 1 TYPICAL GUARD RAIL DETAIL GR02 250906 1 2 3 4 5 6 7 8 3' - 6 " A A SECTION A-A 5" S1.5 5" 3/4" 3/ 4 " 3/16 1 1 / 2 " 1 1 / 2 " BALUSTERS PER ARCH. (4" MAX. SPACE BTWN. BALUSTERS) 2" SQ. MLT. TUBES @ 4'-0" O.C. MAX. 5"X5"X 3/8" THK. STEEL PLATE (4) 3/8" X7" LONG LAG SCREW 6X MIN. BEAM/ STRINGER REQ'D 2X BLK'G @ 48" O.C. PROVIDE 2X BLOCKING @ EA. POST (ONE BAY MIN.) W/ MIN. (4) 16d's WHERE FLOOR JOIST ARE PARALLEL TO BEAM NOTES: OPEN GUARDS SHALL HAVE BALUSTERS OR ORNAMENTAL PATTERNS SUCH THAT A 4" Ø SPHERE CAN NOT PASS THROUGH ANY OPENING (4)1/4"X4 1/2" SDS SCREWS E/S OF POST AND BOTH SIDE (8 TOTAL) 4X8 BLK'G TO RECEIVE SDS SCREWS SCREWS W/ (2) A34 TOP & BOTT. E/S 1 2 3 4 4 5 6 7 8 2" 8 FRONT VIEW 9 9 9 DECK JOIST PER PLAN S1.5 S1.5 S1.5 PLA T E LIN E PLA T E LINE PLA T E LIN E PLA T E LIN E 10 10 PROVIDE H2.5A EA SIDE OF POST @ TOP AND BOTT. (TOTAL 4) TO DECK JOISTS OR BLOCKING 2 Date: 5/7/2026 Address: 2314 W San Lorenzo Ave Santa Ana, CA 92704 Plan Checker: Imelda Gharapetian Permit #: 101126096 Item No. Sheet No.Respond to comments 5 Attachment #1 Please see guardrail calculation and detail in attachment #1 PLAN CHECK CORRECTION RESPONSE (STRUCTURAL) Thanh Huynh Project engineer 1 CITY OF SANTA ANA Planning and Building Agency 0 '::,F(-Tlr)KI A_A I I\L/IV 1 V I L V V TYPICAL GUARD RAIL DETAIL Approved FOR PERMIT ISSUANCE Master ID: Date: O BALUSTERS PER ARCH. (4" MAX. SPACE BTWN. BALUSTERS) Q 2" 5Q. MLT. TUBES @ 4'-0" O.C. MAX. O3 5"X5"X 3/8" THK. STEEL PLATE 40 (4) 3/8" XT LONG LAG SCREW 50 GX MIN. BEAM/ STRINGER REQ'D 2X BLK'G @ 48" O.C. PROVIDE 2X BLOCKING @ EA. P05T (ONE BAY MIN.) W/ MIN. (4) 1 Gd's WHERE FLOOR J015T ARE PARALLEL TO BEAM 07 (4) I /4"X4 1 /2" 5D5 5CREW5 E/5 OF P05T AND BOTH 51DE (8 TOTAL) OS 08 BLK'G TO RECEIVE 5D5 5CPEW5 SCREWS W/ (2) A34 TOP BOTT. E/5 O9 DECK J015T PEP PLAN 10 PROVIDE H2.5A EA 51DE OF P05T @ TOP AND BOTT. (TOTAL 4) TO DECK J015T5 OR BLOCKING NOTES: OPEN GUARDS SHALL HAVE BALUSTERS OR ORNAMENTAL PATTEKN5 SUCH THAT A 4" 0 5PHERE CAN NOT PA55 THROUGH ANY OPENING GR02 250906 Rail height =42.0 in post spacing =4.0 ft Lag screw size:3/8"x 7 in Total number of lag screws:4 Lag screw edge distance E1 =0.75 in Column edge distance C1 =1.5 in Wood Type =DFL Beam width W =5.00 in Beam depth D =9.50 in Base plate length L =5.00 in Base plate width w =5.00 in Lateral force (Uniform) =50.0 plf Lateral force (Concentrate) =200.0 lb CD =1.00 Max. load for design = 200 lbs Shear force per screw = F / 2 = 100.0 lbs Only half of screws work for shear Shear capacity per screw Z = 330.0 lbs OK! Triangular bearing width = X in Fc =625 x 1.0 =625 psi T = C = 625 L X / 2 = 1562.5X lbs Base moment M = ( 1562.5 X )( 4.25 - X / 3 ) = 200 x 42 = 8400.0 in-lbs Find X: 520.8 X² - 6640.6X + 8400 = 0 => X = 1.424 in Tension in screw T = 1112.5 lbs Length of thread penetration p = 3.78125 in Lag screw withdraw capacity per inch W = 305.0 lbs/in Lag screw withdraw capacity Wp = 1153.2 lbs OK! Check combined lateral and withdrawal loads:Angle a =84.86 degree Resultant force Fa =1117.0 lbs Z'a = (W'p)Z' / (W'p)cos2a+Z'sin2a = 1130.5 lbs OK! Base plate moment at column face = 1140.7 in-lbs Base plate thickness treq'd =0.225 in O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR