HomeMy WebLinkAbout2525 N Grand Ave & MTR01 - Plan Rev: 07/16//2019 Page 1 of 2 Eligibility Checklist for Expedited EV Charging Station Permit: Multi-Family Dwellings Type of Charging Station(s) Power Levels (proposed circuit rating) Check one Level 1 110/120 volt alternating current (VAC) at 15 or 20 Amps Level 2 - 3.3 kilowatt (kW) (low) 208/240 VAC at 20 or 30 Amps Level 2 – 6.6kW (medium) 208/240 VAC at 40 Amps Level 2 – 9.6kW (high) 208/240 VAC at 50 Amps Level 2 – 19.2kW (highest) 208/240 VAC at 100 Amps Other (provide detail): Provide rating: Permit Application Requirements: A. Does the application include EVCS manufacturer's specs and installation guidelines? Y N Electrical Load Calculation Worksheet: A. Is an electrical load calculation worksheet included? (CEC 220) Y N B. Based on the load calculation worksheet, is a new electrical service panel upgrade required? Y N 1) If yes, do plans include the electrical service panel upgrade? Y N C. Is the charging circuit appropriately sized for a continuous load of 125%? Y N D. If charging equipment proposed is a Level 2 – 9.6 kW station with a circuit rating of 50 Amps or higher, is a completed panel schedule with electrical calculations included with the single line diagram? Y N Site Plan and Single Line Drawing: A. Is a site plan and separate electrical plan with a single-line diagram included with the permit application? Y N 1) If mechanical ventilation requirements are triggered for indoor venting requirements (CEC 625.52 (B)), is a mechanical plan included with the permit application? Y N B. Is the site plan fully dimensioned and drawn to scale? Y N 1) Showing location, size, and use of all structures Y N 2) Showing location of electrical panel to charging system Y N 3) Showing type of charging system and mounting Y N 480/277level 3 Rev: 07/16//2019 Page 2 of 2 Compliance with the California Electrical Code: A. Does the plan include EVCS manufacturer's specs and installation guidelines? Y N B. Does the electrical plan identify the amperage and location of existing electrical service panel? Y N 1) If yes, does the existing panel schedule show room for additional breakers? Y N C. Is the charging unit rated more than 60 amps or more than 150V to ground? Y N 1) If yes, are disconnecting means provided in a readily accessible location in line of site? (CEC 625.43) Y N D. Does the charging equipment have a Nationally Recognized Testing Laboratory (NRTL) approved listing mark? (UL 2202/UL 2200) Y N E. If trenching is required, is the trenching detail called out? Y N 1) Is the trenching in compliance with minimum cover requirements for wiring methods or circuits? (18” for direct burial per CEC 300.5) Y N Compliance with California Green Building Standards Code: A. Do the CAL Green EV Readiness installation requirements apply to this project: Y N 1) Do the plans demonstrate conformance with mandatory measures for 10% of total parking spaces, for new multifamily dwellings provided for all types of parking facilities, to be electric vehicle charging spaces (EV spaces) capable of supporting future EVCS? (4.106.4.2) Y N 2) Do the construction documents indicate the location of the proposed EV spaces where at least one is located in common use areas and available to all residents for use? (4.106.4.2.1) Calculations for the required number of EV spaces shall be rounded up to the nearest whole number. Y N 3) When EV chargers are installed, EV spaces required by Section 4.106.4.2.2, item 3 shall comply with at least one of the following options: a. The EV space shall be located adjacent to an accessible parking space that complies with CBC Chapter 11A, to allow use of the EV charger from the accessible parking space. b. The EV space shall be located on an accessible route, as defined by CBC Chapter 2, to the building. c. EV charging space(s) comply with Section 4.106.4.2.2, items 1, 2 and 3. Y N Notes: This criteria is intended for an expedited EVCS permitting process. If any items are checked NO, please revise plans to fit within the eligibility checklist; otherwise the permit application may go through the standard plan review and approval process. Electrical plans shall be completed, stamped and signed by a California Licensed Electrical Engineer or a C-10 electrical contractor. EVCS project review is limited to health and safety requirements found under local, state, and federal law. EVCS permit approval is not subject to approval of an association (as defined in Section 4080 of the Civil Code). Project Address: Applicant Signature: Applicants Printed Name: Contractor’s License Number and type: - 2525 North Grand Ave Aaron Wallen EV CHARGING ONLY NO PARKING EV CHARGING ONLY TESLA SUPERCHARGER SANTA ANA, CA - 2525 NORTH GRAND AVENUE 16 SUPERCHARGERS APN: 396-361-05 PROJECT TEAM ELECTRICAL ENGINEER OF RECORD: ALEX SHORTS 10430 SHADY TRAIL #108 DALLAS, TX, 75220 (805) 663-3810 ASHORTS@CRAFTINGEDEN.COM APPLICABLE CODES 2025 CALIFORNIA BUILDING CODE 2025 CALIFORNIA ELECTRICAL CODE 2025 CALIFORNIA FIRE CODE 2025 CALIFORNIA ENERGY CODE SHEET INDEXDESIGN CRITERIA TRT: 458525 SYSTEM SUMMARY SUPERCHARGER SYSTEM SUMMARY EQUIPMENT QTY V4 SUPERCHARGER CABINETS (NON-PSU)1 V4 SUPERCHARGER POSTS (NON-PSU)8 V4 PSU FU (PRE-ASSEMBLED SUPERCHARGER UNIT)1 UTILITY TRANSFORMER 1 SWITCHBOARD 1 LIGHT POLES 3 N S EW AC ALTERNATING CURRENT ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISH FLOOR BLDG BUILDING CLR CLEAR COMM COMMUNICATION CONC CONCRETE DC DIRECT CURRENT DIA DIAMETER DIST DISTANCE (E)EXISTING EA.EACH EGC EQUIPMENT GROUNDING CONDUCTOR EMT ELECTRICAL METALLIC TUBING EQ EQUAL ERMS ENERGY REDUCTION MAINTENANCE SETTINGS ESS ENERGY STORAGE SYSTEM EV ELECTRIC VEHICLE GAB GRADED AGGREGATE BASE GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GFP GROUND FAULT PROTECTOR GND GROUND HVAC HEATING, VENTILATION, & AIR CONDITIONING I CURRENT IMP CURRENT AT MAX POWER INV INVERTER ISC SHORT CIRCUIT CURRENT KVA KILOVOLT AMPERE KW KILOWATT KWH KILOWATT-HOUR LOS LINE OF SIGHT LSIG LONG TIME, SHORT TIME, INSTANTANEOUS GROUND LV LOW-VOLTAGE LVDC LOW VOLTAGE DIRECT CURRENT MAX MAXIMUM MIN MINIMUM MV MEDIUM-VOLTAGE (N)NEW NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NRTL NATIONALLY-RECOGNIZED TESTING LABORATORY NTS NOT TO SCALE OC ON CENTER PCC POINT OF COMMON COUPLING PL PROPERTY LINES PLC POWER LINE COMMUNICATION POE POWER OVER ETHERNET PP POWERPACK PSU PRE-ASSEMBLED SUPERCHARGER UNIT PV PHOTOVOLTAIC PVC POLYVINYL CHLORIDE RSD RAPID SHUTDOWN SCCR SHORT CIRCUIT CURRENT RATING SCH SCHEDULE SQ. IN.SQUARE INCHES SS STAINLESS STEEL SSBJ SUPPLY SIDE BONDING JUMPER SSD SEE STRUCTURAL DRAWINGS STC STANDARD TESTING CONDITIONS TYP TYPICAL UON UNLESS OTHERWISE NOTED VIF VERIFY IN FIELD W WATT ABBREVIATIONS PROJECT SCOPE 1.WIND DESIGN -DESIGN WIND SPEED = 95 MPH -RISK CATEGORY = II -WIND EXPOSURE = C 2.SEISMIC DESIGN -RISK CATEGORY = II -SEISMIC IMPORTANCE FACTOR = 1.0 -SITE CLASS = D -Ss = 1.51 / S1 = 0.5 -Sds = 1.19 / Sd1 = 0.8 -SEISMIC DESIGN CATEGORY = D -BASIC SEISMIC-FORCE-RESISTING SYSTEM = NON-STRUCTURAL COMPONENT -R_po = 1.5 / C_AR = 1.0 3.GROUND SNOW LOAD = 0 PSF SITE LAYOUT AERIAL MAP REFERENCED DOCUMENTS TOPOGRAPHIC SURVEY UTILITY DESIGN STRUCTURAL ENGINEER OF RECORD: YOO JIN KIM TESLA, INC. 129 GERBERA STREET, DANVILLE, CA 94506 M:(949)285-6177 YOKIM@TESLA.COM CIVIL ENGINEER OF RECORD: MICHAEL P. HENDERSON TESLA, INC. 3500 DEER CREEK RD, PALO ALTO, CA 94304 M:(678) 687-1976 MIHENDERSON@TESLA.COM INSTALLATION OF SUPERCHARGERS AND NEW FU PSU (PRE-ASSEMBLED SUPERCHARGER UNIT), ASSOCIATED AC AND DC EQUIPMENT. INSTALLATION OF PRECAST, PRE-FABRICATED & CONCRETE EQUIPMENT PADS AND WALKWAYS. INSTALLATION OF NEW PARKING STRIPING, SIGNAGE AND ADA ACCESS FEATURES. ASPHALT OVERLAY FOR PROPOSED EV ADA STALLS. INSTALLATION OF NEW LED LIGHTING. PROJECT DESIGNER: MUSTAFA HANNOUN TESLA, INC. 1 TESLA RD., AUSTIN, TX 78725 (972) 369-4534   MHANNOUN@TESLA.COM ALL EXISTING AND PROPOSED LOCATIONS ARE BASED OFF THE SURVEYOR'S ESTABLISHED BENCHMARK AND CONTROL. IMPORTANT NOTE: PARKING STALL SCHEDULLE EXISTING STANDARD STALLS UTILIZED AS A RESULT OF THIS PROJECT 21 PROPOSED TESLA STALLS 16 PROPOSED STANDARD STALLS 0 AB1100 EV VAN CREDIT 1 NET STALL COUNT -4 EV CHARGE STALLS PROPOSED 16 ADA EV STALL TYPE CAR VAN AMBULATORY STALLS REQUIRED 1 1 0 STALLS PROPOSED 1 1 0 BASED ON CBC TABLE 11B-228.3.2.1 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S COVER PAGE G-001 REV: B IFP MHANNOUNPLOT DATE: 4/22/2026 11:31 AM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S N S EW AREA OF WORK N S EW NO R T H G R A N D A V E N U E SHEET #SHEET TITLE G-001 COVER PAGE G-002 NOTES G-100 OVERALL SITE PLAN G-101 DEMOLITION PLAN E-101 ELECTRICAL SITE PLAN E-201 SINGLE LINE DIAGRAM E-501 ELECTRICAL DETAILS E-502 ELECTRICAL DETAILS E-601 UTILITY DESIGN PLAN E-701 TITLE 24 A-301 ACCESSIBLE PARKING PLAN A-501 ARCHITECTURAL DETAILS S-301 ENLARGED STRUCTURAL PLAN S-501 STRUCTURAL DETAILS S-502 STRUCTURAL DETAILS S-601 CUTSHEETS -SURVEY B B B B EV CHARGING ONLY NO PARKING EV CHARGING ONLY TESLA SUPERCHARGER SANTA ANA, CA - 2525 NORTH GRAND AVENUE 16 SUPERCHARGERS APN: 396-361-05 PROJECT TEAM ELECTRICAL ENGINEER OF RECORD: ALEX SHORTS 10430 SHADY TRAIL #108 DALLAS, TX, 75220 (805) 663-3810 ASHORTS@CRAFTINGEDEN.COM APPLICABLE CODES 2025 CALIFORNIA BUILDING CODE 2025 CALIFORNIA ELECTRICAL CODE 2025 CALIFORNIA FIRE CODE 2025 CALIFORNIA ENERGY CODE SHEET INDEXDESIGN CRITERIA TRT: 458525 SYSTEM SUMMARY SUPERCHARGER SYSTEM SUMMARY EQUIPMENT QTY V4 SUPERCHARGER CABINETS (NON-PSU)1 V4 SUPERCHARGER POSTS (NON-PSU)8 V4 PSU FU (PRE-ASSEMBLED SUPERCHARGER UNIT)1 UTILITY TRANSFORMER 1 SWITCHBOARD 1 LIGHT POLES 3 N S EW AC ALTERNATING CURRENT ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISH FLOOR BLDG BUILDING CLR CLEAR COMM COMMUNICATION CONC CONCRETE DC DIRECT CURRENT DIA DIAMETER DIST DISTANCE (E)EXISTING EA.EACH EGC EQUIPMENT GROUNDING CONDUCTOR EMT ELECTRICAL METALLIC TUBING EQ EQUAL ERMS ENERGY REDUCTION MAINTENANCE SETTINGS ESS ENERGY STORAGE SYSTEM EV ELECTRIC VEHICLE GAB GRADED AGGREGATE BASE GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GFP GROUND FAULT PROTECTOR GND GROUND HVAC HEATING, VENTILATION, & AIR CONDITIONING I CURRENT IMP CURRENT AT MAX POWER INV INVERTER ISC SHORT CIRCUIT CURRENT KVA KILOVOLT AMPERE KW KILOWATT KWH KILOWATT-HOUR LOS LINE OF SIGHT LSIG LONG TIME, SHORT TIME, INSTANTANEOUS GROUND LV LOW-VOLTAGE LVDC LOW VOLTAGE DIRECT CURRENT MAX MAXIMUM MIN MINIMUM MV MEDIUM-VOLTAGE (N)NEW NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NRTL NATIONALLY-RECOGNIZED TESTING LABORATORY NTS NOT TO SCALE OC ON CENTER PCC POINT OF COMMON COUPLING PL PROPERTY LINES PLC POWER LINE COMMUNICATION POE POWER OVER ETHERNET PP POWERPACK PSU PRE-ASSEMBLED SUPERCHARGER UNIT PV PHOTOVOLTAIC PVC POLYVINYL CHLORIDE RSD RAPID SHUTDOWN SCCR SHORT CIRCUIT CURRENT RATING SCH SCHEDULE SQ. IN.SQUARE INCHES SS STAINLESS STEEL SSBJ SUPPLY SIDE BONDING JUMPER SSD SEE STRUCTURAL DRAWINGS STC STANDARD TESTING CONDITIONS TYP TYPICAL UON UNLESS OTHERWISE NOTED VIF VERIFY IN FIELD W WATT ABBREVIATIONS PROJECT SCOPE 1.WIND DESIGN -DESIGN WIND SPEED = 95 MPH -RISK CATEGORY = II -WIND EXPOSURE = C 2.SEISMIC DESIGN -RISK CATEGORY = II -SEISMIC IMPORTANCE FACTOR = 1.0 -SITE CLASS = D -Ss = 1.51 / S1 = 0.5 -Sds = 1.19 / Sd1 = 0.8 -SEISMIC DESIGN CATEGORY = D -BASIC SEISMIC-FORCE-RESISTING SYSTEM = NON-STRUCTURAL COMPONENT -R_po = 1.5 / C_AR = 1.0 3.GROUND SNOW LOAD = 0 PSF SITE LAYOUT AERIAL MAP REFERENCED DOCUMENTS TOPOGRAPHIC SURVEY UTILITY DESIGN STRUCTURAL ENGINEER OF RECORD: YOO JIN KIM TESLA, INC. 129 GERBERA STREET, DANVILLE, CA 94506 M:(949)285-6177 YOKIM@TESLA.COM CIVIL ENGINEER OF RECORD: MICHAEL P. HENDERSON TESLA, INC. 3500 DEER CREEK RD, PALO ALTO, CA 94304 M:(678) 687-1976 MIHENDERSON@TESLA.COM INSTALLATION OF SUPERCHARGERS AND NEW FU PSU (PRE-ASSEMBLED SUPERCHARGER UNIT), ASSOCIATED AC AND DC EQUIPMENT. INSTALLATION OF PRECAST, PRE-FABRICATED & CONCRETE EQUIPMENT PADS AND WALKWAYS. INSTALLATION OF NEW PARKING STRIPING, SIGNAGE AND ADA ACCESS FEATURES. ASPHALT OVERLAY FOR PROPOSED EV ADA STALLS. INSTALLATION OF NEW LED LIGHTING. PROJECT DESIGNER: MUSTAFA HANNOUN TESLA, INC. 1 TESLA RD., AUSTIN, TX 78725 (972) 369-4534   MHANNOUN@TESLA.COM ALL EXISTING AND PROPOSED LOCATIONS ARE BASED OFF THE SURVEYOR'S ESTABLISHED BENCHMARK AND CONTROL. IMPORTANT NOTE: PARKING STALL SCHEDULLE EXISTING STANDARD STALLS UTILIZED AS A RESULT OF THIS PROJECT 21 PROPOSED TESLA STALLS 16 PROPOSED STANDARD STALLS 0 AB1100 EV VAN CREDIT 1 NET STALL COUNT -4 EV CHARGE STALLS PROPOSED 16 ADA EV STALL TYPE CAR VAN AMBULATORY STALLS REQUIRED 1 1 0 STALLS PROPOSED 1 1 0 BASED ON CBC TABLE 11B-228.3.2.1 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 MHANNOUNPLOT DATE: 4/23/2026 9:56 AM N S EW AREA OF WORK N S EW NO R T H G R A N D A V E N U E B B SHEET #SHEET TITLE G-001 COVER PAGE G-002 NOTES G-100 OVERALL SITE PLAN A-301 ACCESSIBLE PARKING PLAN A-501 ARCHITECTURAL DETAILS S-301 ENLARGED STRUCTURAL PLAN S-501 STRUCTURAL DETAILS S-502 STRUCTURAL DETAILS S-601 CUTSHEETS -SURVEY B ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ANY OTHER REGULATING AUTHORITIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK. PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FROM TESLA OF ANY DISCREPANCIES. ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT THE SUBCONTRACTORS SOLE EXPENSE. SUBCONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO TESLA FOR APPROVAL BEFORE MAKING ANY CHANGES. DEVIATION FROM PLANS BEFORE WRITTEN APPROVAL FROM TESLA PLACES LIABILITY ON THE SUBCONTRACTOR. ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, CONTRACTOR SHALL USE STANDARD CONSTRUCTION PRACTICES. ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT TO MATCH EXISTING FINISHES. ANY METAL SHAVINGS FROM SITE WORK SHALL BE CLEANED FROM ALL SURFACES WHERE OXIDIZED OR CONDUCTIVE METAL SHAVINGS MAY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE. APPROVALS FROM BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE DRAWINGS. NEW PAVEMENT INSTALLED AS PART OF THIS PROJECT SHALL MATCH EXISTING PAVEMENT SECTION. ASPHALT AND GAB DEPTHS SHALL BE MAINTAINED. GENERAL NOTES SUPERCHARGER NOTES 1.ALL CONDUIT FURNISHED AND INSTALLED BY CONTRACTOR. ALL WIRING FURNISHED BY TESLA AND INSTALLED BY CONTRACTOR. 2.ALL BUSHINGS AND WIRING INTERNAL OF PROPOSED SERVICE EQUIPMENT PROVIDED BY MANUFACTURER. ANY MODIFICATIONS SHALL REQUIRE ENGINEERING APPROVAL PRIOR TO ANY CHANGES BEING MADE. 3.ALL ALUMINUM(AI) CONDUCTORS TO RECEIVE ANTI-OXIDATION COATING DURING INSTALLATION. ALL OTHER CONDUCTORS ARE COPPER UNLESS OTHERWISE NOTED. 4.THE FOLLOWING CHARGING CABINETS AND THE CHARGING POSTS USED ON THIS PROJECT COMPLY WITH THE FOLLOWING STANDARDS: ·IEC 61851-23: 2014 / EN 61851-23: 2014 ·UL 2202: 2009(R2012) ·CAN CSA C22.2 NO. 107.1-01(R2011) 5.THE AFOREMENTIONED STANDARDS IDENTIFY THE REQUIREMENTS MET BY THE EQUIPMENT, INCLUDING BUT NOT LIMITED TO: ·PROTECTION AGAINST ELECTRIC SHOCK ·OVERLOAD AND SHORT CIRCUIT PROTECTION ·FAULT PROTECTION ·DEGREES OF PROTECTION AGAINST ACCESS TO HAZARDOUS LIVE PARTS ·THE INTERNAL COMPONENTS OF THE SYSTEM ARE PROPRIETARY. ANY QUESTIONS CONCERNING ACTUAL INTERNAL PROTECTIVE DEVICES MUST BE COORDINATED DIRECTLY WITH TESLA. 6.TESLA SUPERCHARGER SIGNAL WIRING RATED 1000V AND USED FOR POWER LIMITED CLASS 1 CIRCUITS SHALL BE PERMITTED TO RUN IN CONDUITS, CABLE TRAYS, WIRE WAYS, OR RACEWAYS ALONG WITH ASSOCIATED DC CONDUCTORS AS ALLOWED PER NEC 725.48(B)(1) AND 620.36. 7.SUPERCHARGER CABINET AC CONDUCTORS SIZED UNDER ENGINEERING SUPERVISION USING THERMAL MODELING SOFTWARE. SPECIFICATIONS ABOUT THE TRENCHING REQUIREMENTS ARE SHOWN IN E-501 8.FOR DC RUNS IN EXCESS OF 330 FEET, CONTACT TESLA. 9.UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC OR UL LISTED HDPE. THE ABOVEGROUND PORTION OF AN UNDERGROUND/ABOVEGROUND TRANSITION SHALL BE SCHEDULE 80 PVC OR UL LISTED HDPE. 10.ABOVEGROUND CONDUITS EXPOSED TO VEHICULAR OR EQUIVALENT PHYSICAL DAMAGE SHALL BE RMC. ABOVEGROUND CONDUITS NOT EXPOSED TO VEHICULAR OR EQUIVALENT DAMAGE SHALL BE PERMITTED TO BE EMT. 11.WIRE SPLICES ARE NOT PERMITTED TO EXTEND WIRE RUN LENGTH. CONTRACTOR IS RESPONSIBLE FOR RERUNNING FULL LENGTH OF WIRE IF RUN LENGTH IS MISCALCULATED. 12.SPECIAL INSPECTION IS REQUIRED FOR ALL POST-INSTALLED CONCRETE ANCHORS. 13.PLANT GUARANTEE: CONTRACTOR SHALL GUARANTEE ALL PLANTS FOR A PERIOD OF ONE (1) YEAR FROM DATE OF PROJECT ACCEPTANCE BY THE OWNER. CONTRACTOR IS RESPONSIBLE FOR PLANT MAINTENANCE FOR THE FIRST GROWING SEASON. 14.IF EXISTING GRASS IS DAMAGED/REMOVED DURING CONSTRUCTION, CONTRACTOR SHALL APPLY SEED PER HYDROSEED METHOD. RATING OF SEED SHALL BE PER DISTRIBUTOR BASED ON SPECIES TYPE. 15.CONTRACTOR SHALL MATCH EXISTING LANDSCAPE; USE GRASS, RIVER ROCK, MULCH ETC. TO MATCH EXISTING LANDSCAPE AROUND EQUIPMENT, UNLESS OTHERWISE NOTED. 16.CONTRACTOR TO INSTALL WEED BARRIER IN FRONT OF SUPERCHARGER CABINETS AND SWITCHBOARD. BARRIER TO EXTEND FULL WIDTH AND DEPTH OF NEC REQUIRED WORKING CLEARANCES. GENERAL NOTES 1.ALL ELECTRICAL WORK SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE AS AMENDED BY APPLICABLE STATE AND LOCAL CODES. 2.ALL WIRING SHALL BE MANAGED IN A PROFESSIONAL, WORKMAN-LIKE MANNER AND MUST BE SUPPORTED, SECURED, AND PROTECTED TO PREVENT DAMAGE. 3.AC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER ART 210.5 OR 215.12. UNLESS OTHERWISE REQUIRED BY ART 210.5(1) OR AHJ, COLOR-CODING OF POWER CONDUCTORS SHALL BE AS FOLLOWS: CONDUCTOR 277/480V 120/208V PHASE A BROWN BLACK PHASE B ORANGE RED PHASE C YELLOW BLUE NEUTRAL GRAY WHITE 4.DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED PER ART 210.5 OR 215.12: CONDUCTOR STD COLOR ALT COLOR DC+RED RED-STRIPED DC-BLACK BLACK-STRIPED 5.TERMINATIONS OF AC, DC, AND COMMUNICATIONS CONDUCTORS SHALL BE PROFESSIONALLY AND LEGIBLY LABELED WITH CIRCUIT SCHEDULE IDENTIFIER, CONDUCTOR SIZE (AS APPLICABLE) AND TERMINATION TORQUE. 6.ALL EQUIPMENT SHALL BE LISTED BY A NRTL IN COMPLIANCE WITH ART 110.3. WHERE EXISTING NRTL LISTING CANNOT BE MAINTAINED, ENGINEERING APPROVAL SHALL BE OBTAINED PRIOR TO EQUIPMENT MODIFICATION, AND THE EQUIPMENT SHALL BE RELISTED BY A SUITABLE NRTL. 7.UNDERGROUND CONDUCTORS & CABLES TO BE INSTALLED IN CONDUIT UON. 8.ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NRTL LISTING. 9.REFER TO MANUFACTURER'S CURRENT PLANNING AND INSTALLATION MANUAL FOR TORQUE SPECS FOR ALL BOLTS AND TERMINAL CONNECTIONS. 10.ALL CONDUCTOR TERMINATIONS ON BUSSING OR TRANSFORMER SPADES SHALL BE MADE WITH HIGH-PRESS CRIMP LUGS UON. 11.ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE PROPERLY INSTALLED WITH BEST PRACTICES INCLUDING BUT NOT LIMITED TO: ·USE OF TERMINATION EQUIPMENT RATED FOR ALUMINUM AT THE CONDUCTOR TEMPERATURE, CURRENT, AND VOLTAGE ·ALLOWANCE FOR MOVEMENT DUE TO THERMAL EXPANSION/CONTRACTION ·PROPER COATING OF EXPOSED ALUMINUM WITH ANTI-OXIDIZATION COMPOUND ·USE OF CALIBRATED DEVICES TO TORQUE AND MARK TERMINALS TO REQUIRED SETTINGS 12.DUCT SEAL COMPOUND SHALL BE APPLIED WHEREVER CONDUITS TRANSITION INDOOR/OUTDOOR OR UNDERGROUND/ABOVEGROUND. REFER TO EQUIPMENT NOTES FOR ADDITIONAL DUCT SEAL REQUIREMENTS. 13.BELL ENDS SHALL BE INSTALLED WHEREVER CONDUIT ENTERS EQUIPMENT FROM UNDERGROUND AND WHEREVER POTENTIAL FOR DAMAGE TO CONDUCTORS IS PRESENT AT ANY POINT. BELL ENDS SHALL NOT PREVENT THE USE OF GROUNDING FITTINGS OR COUPLERS WHEN REQUIRED. 14.ALL STUB-UPS WITHIN FLOOR-MOUNTED EQUIPMENT SHALL BE 3-5" ABOVE FINISHED GRADE. 15.ALL CONDUITS EXPOSED TO VEHICULAR OR EQUIVALENT PHYSICAL DAMAGE SHALL BE RIGID GALVANIZED STEEL. 16.GROUND LUGS SHALL BE RATED FOR THEIR ENVIRONMENT AND CONDITION OF USE. ELECTRICAL NOTES SITE LEGEND (EXISTING OBJECTS)UTILITY SOUTHERN CALIFORNIA EDISON CATEGORY ITEMS TESLA UTILITY PRIMARY PRIMARY TRENCHING X INSTALL PRIMARY CONDUIT X INSTALL PULL ROPE X INSTALL PRIMARY FEEDERS X PROVIDE PRIMARY FEEDERS X PROVIDE ROAD CUTS / ROAD BORES X PAVEMENT REPLACEMENT X TRANSFORMER INSTALL TRANSFORMER PAD X PROVIDE TRANSFORMER X INSTALL TRANSFORMER X INSTALL CONNECTIONS - PRIMARY X INSTALL CONNECTIONS - SECD X SWITCHBOARD PROVIDE METER X INSTALL METER X LAND SECONDARY FEEDERS X SECONDARY SECONDARY TRENCHING X INSTALL SECONDARY CONDUIT X INSTALL PULL ROPE X INSTALL SECONDARY FEEDERS X PROVIDE SECONDARY FEEDERS X PROVIDE ROAD CUTS / ROAD BORES X PAVEMENT REPLACEMENT X SCOPE OF WORK UNDERGROUND SANITARY LINE CLEANOUT GREASE TRAP FIRE HYDRANT IRRIGATION CONTROL VALVE LIGHT POLE UTILITY POLE HANDICAP PARKING SIGN DECIDUOUS TREE PALM TREE SS UNDERGROUND ELECTRIC LINEUE OVERHEAD ELECTRIC LINEOE 17. THE GROUND-FAULT PROTECTION SYSTEM SHALL BE PERFORMANCE TESTED WHEN FIRST INSTALLED ON SITE. THIS TESTING SHALL BE CONDUCTED BY A QUALIFIED PERSON(S) USING A TEST PROCESS OF PRIMARY CURRENT INJECTION, IN ACCORDANCE WITH INSTRUCTIONS THAT SHALL BE PROVIDED WITH THE EQUIPMENT, A WRITTEN RECORD OF THIS TESTING SHALL BE MADE BE AVAILABLE TO THE AUTHORITY HAVING JURISDICTION. 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S NOTES G-002 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:55 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S EV CHARGING ONLY NO PARKING EV CHARGING ONLY (E) 90' R.O.W. DEDICATION (E) 20' BUILDING SETBACK (E) 6' ELECTRIC EASEMENT (E) PROPERTY LINE (E) 15' BUILDING SETBACK - E-101 (E) BUILDING (E) PARKING STRIPING, TYP (E) BUILDING OUTLINE (E) LANDSCAPE (E) CONCRETE GUTTER (E) 7'-5" CONCRETE WALKWAY 19' (N) 24'-1" DRIVE AISLE WIDTH (E) 30'-6" ENTRANCE/ EXIT WIDTH (E) 31'-9" ENTRANCE/ EXIT WIDTH 18' 27'-2"27'-3" 25'-6" 25'-7"25'-8"24' 24'-2" OVERALL SITE PLAN 1/32" = 1'-0" N S EW08'64'32'16' 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S OVERALL SITE PLAN G-100 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:55 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S NO R T H G R A N D A V E N U E EV CHARGING ONLY NO PARKING EV CHARGING ONLY (E) WHEELSTOP, TYP. (E) CONCRETE WALKWAY, TYP. (E) CONCRETE CURB, TYP. (E) ASPHALT (E) PILLAR, TYP. (E) PARKING STRIPING, TYP. (E) LIGHT POLE, TYP. (E) PROPERTY LINE (N) 25'-8" DRIVE AISLE WIDTH (N) EV MINI REBOUNDING BOLLARD, (TYP. 12), PER STRUCTURAL (N) STANDARD ACCESSIBLE EV CHARGE STALL, REF. G/A-501 (N) VAN ACCESSIBLE EV CHARGE STALL, REF. G/A-501 (N) EV MINI REBOUNDING BOLLARD MOUNTED ACCESSIBLE SIGN, REF. A/A-501 (N) CURB, REF. D/A-501 PROVIDE PAVING AS REQUIRED TO ACHIEVE 2% MAX SLOPE ALL DIRECTIONS AT ACCESSIBLE EV CHARGE STALLS AND ACCESS AISLE. (N) 4'' THICK CONCRETE WALKWAY W/2% MAX SLOPE ALL DIRECTIONS AT CHARGE POST ACCESS AREAS, REF. C/A-501 (N) ACCESSIBLE EV STALL CHARGER POST BASES MOUNTED FLUSH W/PAVING (N) ACCESSIBLE ROUTE TO (E) PEDESTRIAN ENTRANCE (N) 4'' WIDE WHITE STRIPING WITH 4'' WIDE WHITE CROSS STRIPING AT 36'' O.C. PROVIDE CABLE HANDLE ACCESSIBILITY ATTACHMENT AT ACCESSIBLE CHARGE POSTS, REF. I/A-501 (E) LANDSCAPE 5'12'9' 5'-2" 18' TYP. 3' 4' TYP. 2'-6" TYP. 8' (N) PAYMENT KIOSK, PER STRUCTURAL (E) ACCESSIBLE ROUTE 30"X48" CLEAR FLOOR SPACE. OPERABLE PART OF CHARGE POST AT 48" MAX. A.F.F (N) TACTILE SURFACE TILE W/ TRUNCATED DOMES, REF. J/A-501 (E) BUILDING (E) 180.69(E) 180.65 (E) 180.54 (E) 180.51 (E) 180.37 2'-6" 4' EV CHARGE STALL SCHEDULE EV CHARGE STALLS PROPOSED 16 ADA EV STALL TYPE CAR VAN AMBULATORY STALLS REQUIRED 1 1 0 STALLS PROPOSED 1 1 0 BASED ON CBC TABLE 11B-228.3.2.1 N S EWACCESSIBLE PARKING PLAN 3/16" = 1'-0" SITE LEGEND CODE COMPLIANCE: ALL WORK SHALL BE INSTALLED IN COMPLIANCE WITH CALIFORNIA BUILDING CODE. APPLICABLE CODE ARE AS STATED. ACCESSIBLE STALLS STANDARD: 11B-812.6.2 VAN: 11B-812.6.1 AMBULATORY:11B-812.6.3 ACCESS AISLE:11B-812.7 ACCESSIBLE ROUTE: 11B-812.5 ISA SIGNAGE:11B-812.8 ADA SURFACE MARKINGS:11B-812.9 PER CALIFORNIA ASSEMBLY BILL AB-970: IF AN ELECTRIC VEHICLE CHARGING STATION AND ANY ASSOCIATED EQUIPMENT INTERFERE WITH, REDUCE, ELIMINATE, OR IN ANY WAY IMPACT THE REQUIRED PARKING SPACES FOR EXISTING USES, THE CITY, COUNTY, OR CITY AND COUNTY SHALL REDUCE THE NUMBER OF REQUIRED PARKING SPACES FOR THE EXISTING USES BY THE AMOUNT NECESSARY TO ACCOMODATE THE ELECTRIC VEHICLE CHARGING STATION AND ANY ASSOCIATED EQUIPMENT. ACCESSIBLE CHARGE POST POINT-OF-SALE DEVICE NOTES: P.O.S DEVICE COMPLIES WITH CBC 11B-707.7.2 - THE CHARACTERS DISPLAYED ON THE SCREEN SHALL BE SANS SERIF FONT. CHARACTERS SHALL BE 3/16 INCH HIGH MINIMUM BASED ON THE UPPERCASE LETTER "I". CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. P.O.S. DEVICE COMPLIES WITH CBC 11B-707.9.1.2 THE P.O.S. IS RADIO-FREQUENCY IDENTIFICATION(RFID) DEVICE ENABLED WITH TAP-TO-PAY FUNCTIONALITY NOTES 0 1'12'8'4' SPOT ELEVATION EXISTING ELEVATION(E) XX.XX (N) ACCESSIBLE ROUTE (N) SUPERCHARGER POST (N) FIXED BOLLARD (N) CONCRETE CURB (N) EV MINI REBOUNDING BOLLARD SIGN (N) CONCRETE PAVING (N) UTILITY BOLLARD (N) POLE-MOUNTED LIGHT FIXTURE (N) EV MINI REBOUNDING BOLLARD (N) FULL DEPTH ASPHALT 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S ACCESSIBLE PARKING PLAN A-301 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:56 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S NO R T H G R A N D A V E N U E B B B B B B 04/21/2026 MOUNTING OPTIONS: 1.SIGN CAN BE INSTALLED ON WALL USING ANCHOR SYSTEM MATCHING WALL TYPE. 2.SIGN CAN BE POLE MOUNTED PER SPECIFICATIONS IN POST MOUNTED SIGN DETAILS. SIGN MATERIAL: ALUMINUM A501.1617 TESLA EV STALL PARKING SIGN - VAN ACCESSIBLE RA TESLA EV STALL PARKING SIGN - VAN ACCESSIBLE NTS 12"12"12"12"12"12"12" 18" 1/2" RADIUS SIGN CORNER WHITE SYMBOL WHITE TEXT VAN ACCESSIBLE DESIGNED FOR DISABILITY ACCESS - USE LAST WHITE TEXT 6" SOLID FEDERAL BLUE #15090 IN FED STANDARD 595C BACKGROUND PAINT 60" MIN A.F.F. SIGN TO HAVE REFLECTIVE FINISH B A501.1603 BOLLARD MOUNTED ACCESSIBLE EV SIGN DETAIL RB EV MINI REBOUNDING BOLLARD MOUNTED EV SIGN NTS REBOUNDING BOLLARD PRE-ASSEMBLED WITH PRE-CAST SUPERCHARGER FOUNDATION, PER STRUCTURAL 3' NOTE: SIGNAGE MUST BE PLACED WITHIN THE PROJECTED HEAD END OF THE PARKING SPACE IN CALIFORNIA, ISA SIGNAGE PER CBC 11B-812.8 80 " M I N . T O B O T T O M O F AN Y S I G N F R E E S T A N D I N G IN C I R C U L A T I O N P A T H S 72 " T Y P . - N O T L O C A T E D I N C I R C U L A T I O N P A T H S BOLTED OR WELDED CAP ACCESSIBLE SIGN & DESIGNED FOR DISABLED ACCESS - USE LAST SIGN PER PLAN & PER B EV PARKING SIGN, IF REQUIRED PER PLAN 18" 12" 2" X 2" SQUARE POWDER COATED GRAY HSS TUBE SIGN POST, ONLY REQUIRED WHEN SIGNS ARE REQUIRED EPOXY BEAD BETWEEN POST & SIGN 3/8" DIA. ALUMINUM SECURITY PIN BOLT RIVET W/ 3/4" DIA. DOME HEAD FLANGE & .330" GRIP LENGTH A 4" WHITE BORDER AT AISLE AND PARKING, TYP. 18' MIN EV CHARGING ONLY VAN ACCESSIBLE 12' MIN CODE COMPLIANCE: STALL SPECIFICATIONS PER CBC 11B-812.6 SURFACE MARKINGS PER CBC 11B-812.9 ACCESS AISLE PER CBC11B-812.7 A501.1612 EV CHARGE ACCESSIBLE STALLS - VAN & STANDARD RA NO PARKING 5' MIN 36" MAX NTS EV CHARGING ONLY STD ACCESSIBLE 9' MIN 4" WHITE 45° LINES AT 36" O.C. MAX. TYP. MATCH EXISTING ANGLE ORIENTATION WHERE APPLICABLE SIGN PER PLAN, TYP. NOTES: MAX.SLOPE 1:48 AT STALL AND AISLE IN ALL DIRECTIONS,TYP. ALL DIMS ARE TO CENTERLINE OF STRIPING WHITE LETTERING 12" MIN HEIGHT, TYP. ACCESSIBLE EV CHARGE STALLS VAN & STANDARD - CBCG I 48" MAX. TO TOP OF LOOP HANDLE ATTACHMENT A501.1639 V4 LOOP HANDLE ACCESSIBILITY DETAIL V4 LOOP HANDLE ACCESSIBILITY DETAIL NTS FINISHED GRADE V4 TESLA SUPERCHARGER POST (N) LOOP HANDLE ATTACHMENT OPERABLE PART A501.1633 WALKWAY PAVEMENT DETAIL RB WALKWAY PAVEMENT DETAIL NTS 4" MIN. THICK CONCRETE W/ 6x6 WWF-W1.4/1.4 @ MID SLAB PER PLAN COMPACTED SUBGRADE 4" MIN. AGGREGATE SUBBASE COMPACT TO 95% STANDARD PROCTOR DENSITY 1/2" FLUSH LEVEL CONNECTION @NEW OR EXISTING PAVED SURFACES 1/2" @TURF NOTES: 1.EXPANSION JOINTS SHALL BE LOCATED WHERE SIDEWALK ABUTS CONCRETE DRIVEWAYS, CURB, OR OTHER ADJACENT STRUCTURES. 2.1/2" BITUMINOUS JOINT FILLER SHALL BE INSTALLED AT EXPANSION JOINT LOCATIONS AND SHALL EXTEND THE FULL DEPTH OF THE CONCRETE. 3.1" DEEP CONTRACTION JOINTS SHALL BE PLACED AT INTERVALS OF APPROXIMATELY 15' OR AT A SPACING THAT MATCHES THE ADJACENT CURB. 4.FORMED CONTRACTION JOINTS SHALL BE FINISHED WITH A TOOL HAVING A 1/4" RADIUS. 5.SCORED JOINTS SHALL BE 1/4" DEEP AND PLACED AT THE SPACING INDICATED FOR THE WIDTH OF SIDEWALK OR MATCH SCORED JOINTS OF ADJACENT CURB. 6.CONCRETE SHALL BE FINISHED BY MEANS OF A FLOAT, STEEL TROWEL AND BROOMED WITH FINE BRUSH IN A TRANSVERSE DIRECTION. 7.1/4" DEEP SCORED JOINTS (TYP) SHALL BE SPACED AT 6' OR EQUAL TO SIDEWALK WIDTH. 8.60' MAX SPACING BETWEEN EXPANSION JOINTS. C SEAL WITH EMULSIFIED ASPHALT ASPHALT PAVEMENT SECTION TO MATCH EXISTING TACK COAT PRIME COAT 3" ORIGINAL SAW CUT FOR DEMOLITION 6" 3" NEW PAVEMENT EXISTING PAVEMENT SAW CUT EXISTING PAVEMENT TO DEPTH OF NEW SURFACE COURSE PRIOR TO FINISH PAVING COMPACTED SUBGRADE COMPACTED GRADED AGGREGATE BASE A501.1600 NEW AND EXISTING ASPHALT PAVEMENT JOINT DETAIL RA NEW/EXISTING ASPHALT PAVEMENT JOINT DETAIL NTSF NOTE: 1. ASPHALT PAVEMENT SECTION DESIGN AND CONSTRUCTION SHALL COMPLY WITH THE INFORMATION PRESENTED IN THE AVAILABLE GEOTECHNICAL EVALUATION REPORT, OR MATCH EXISTING PAVEMENT SECTION. 2. MATERIALS AND INSTALLATIONS SHALL COMPLY WITH THE CALTRANS STANDARD SPECIFICATIONS, LATEST VERSION; SECTION 39, HOT MIX ASPHALT(HMA). 3. PRIME COAT SHALL BE APPLIED TO ALL SUBBASE SURFACES PRIOR TO PLACING ASPHALT PAVEMENT. 4. TACK COAT SHALL BE APPLIED TO ALL ABUTTING ASPHALT PAVEMENT AND CONC. PAVEMENT SURFACES, PRIOR TO PLACING ASPHALT PAVEMENT. COMPACTED GRADED AGGREGATE BASE HMA SURFACE COURSE HMA BASE COURSE COMPACTED SUBGRADE PRIME COAT A501.1613 ASPHALT PAVEMENT SECTION RA ASPHALT PAVEMENT SECTION DETAIL NTS TACK COAT E A501.1607 CONCRETE CURB DETAIL RA HEADER CURB NTS 6" 14" 1/2" AT TURF, 2" AT PLANTER 6" STEEL TROWEL FINISH CONC. CURB W/ 1/2" ROUNDED EDGES (PROVIDE EXPANSION JOINT AT 45'-0" O.C. MAX. - TOOLED JOINTS AT 15'-0" O.C. MAX.) FOR CONCRETE PAVING ALIGN JOINTS WITH CONCRETE PAVING JOINTS. 6" MIN. COMPACTED GRADED AGGREGATE BASE10"6"6" 6" NOTE: CONTRACTOR SHALL ASSESS EXISTING CURB AND INSTALL PROPOSED CURB TO MATCH AHJ STANDARDS IF ANY D TOP VIEW BOTTOM VIEW CONCRETE SURFACES: ANCHOR WITH (4) MANUFACTURER PROVIDED CONCRETE ANCHORS LANDSCAPE AREAS: ANCHOR WITH (4) MIN. 12" LONG J-HOOK REBAR ANCHORS 3'-6" NTS 2'-4" Ø0.5" ANCHOR HOLE (TYP.) 11" 8.73" S501.1642 TRASH BIN DETAIL RA (E) CONCRETE SLAB OR LANDSCAPE FRONT VIEW TRASH & RECYCLING BIN DETAIL NOTE: TRASH & RECYCLING BINS TO BE PROVIDED BY TESLA RECYCLE ONLY USE BLUE BIN W/ "RECYCLE" TEXT & SYMBOLS IN LOCATIONS INDICATED ON SITE PLAN (IF ANY) H A NOTE: TACTILE WARNING SURFACE TILE WITH TRUNCATED DOMES AND BEVELED EDGES, CONFORMING TO ADA & CBC REQUIREMENTS. COLOR YELLOW AND APPROXIMATE 33538 OF SAE AMSSTD-595A. SURFACE APPLIED TO (E) PAVING WITH ADHESIVE, PERIMETER FASTENERS, AND CAULK PER MANUFACTURERS INSTRUCTIONS. 2.3"-2.4" 2.3"-2.4" .9"-.92" .45" - .47" .2" .135" 12 CROSS SECTION, TYP. TILE JOINT FLUSH TRANSITION 2.3"-2.4" A501.1601 TRUNCATED DOMES DETAIL RA TACTILE SURFACE TILE W/ TRUNCATED DOMES NTS - - .65" MIN J 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S DETAILS A-501 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:56 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S B 04/21/2026 EV CHARGING ONLY NO PARKING EV CHARGING ONLY (N) SUPERCHARGER CABINET, (TYP. 2), REF. B/S-501 (N) SUPERCHARGER CABINET CAST IN PLACEPAD, REF. A/S-501 (N) SUPERCHARGER SWITCHBOARD, REF. E/S-501 (N) SUPERCHARGER SWITCHBOARD CAST IN PLACE PAD, REF. A/S-501 (N) LIGHT POLE FOUNDATION, REF. C/S-501 (N) ACCESS POINT MOUNTED ON LIGHT POLE, REF. C/S-501 (N) UTILITY BOLLARD, (TYP. 6), PER UTILITY DESIGN (N) EV MINI REBOUNDING BOLLARD, (TYP. 12), REF. S-502 (N) TRANSFORMER PAD, PER UTILITY DESIGN (N) RECYCLE/ TRASH BIN, PER ARCHITECTURAL (N) PRE-ASSEMBLED SUPERCHARGER UNIT - (1) V4 CABINET, (8) POSTS & (1) ENCLOSED CIRCUIT BREAKER, REF. A/S-502 5'12'9'9' TYP. 18' TYP. 4'-7" 1" 4'-10" 5' TYP. 5' TYP. 12'-2" 5'-7" 12'-2" 1'-9" 4'-6" 3' 13'-8" 5'-1"23'-10" 2'-2" 27' 4' TYP. 3' TYP. (N) HOUSEKEEPING PAD (N) SUPERCHARGER POST W/ PLP FOUNDATION, (TYP. 2), REF. C/S-502 (N) SUPERCHARGER POST W/ CAST IN PLACE FOUNDATION, (TYP. 6), REF. B/S-502 (N) PAYMENT KIOSK, REF. E/S-502 1'-6" 3'4'-7" 11'-2" (N) FIXED BOLLARD, (TYP. 7), REF. F/S-501 2' 19'-11" 4'-2"5'-2" INSTALL 10'X12' PRECAST SLAB BOX FOR 3Ø PAD-MOUNTED TRANSFORMER (UP TO 5,000 kVA) PER SOUTHERN CALIFORNIA EDISON (SCE) UNDERGROUND STRUCTURES STANDARDS SS 535 (EFFECTIVE DATE: 07-26-2019), REF. S-601. TRANSFORMER INSTALLATION, CONNECTION AND ENERGIZATION ARE THE SOLE RESPONSIBILITY OF SCE (N) TACTILE SURFACE TILE W/ TRUNCATED DOMES, PER ARCHITECTURAL STRUCTURAL DESIGN CRITERIA: DESIGN CODE: - 2025 CBC DESIGN CRITERIA: 1. WIND DESIGN - DESIGN WIND SPEED = 95 MPH (ULTIMATE) - RISK CATEGORY = II - WIND EXPOSURE = C 2. SEISMIC DESIGN - RISK CATEGORY = II - SEISMIC IMPORTANCE FACTOR = 1.0 - SITE CLASS = D - Ss = 1.51 / S1 = 0.5 - Sds = 1.19 / Sd1 = 0.8 - SEISMIC DESIGN CATEGORY = D - BASIC SEISMIC-FORCE-RESISTING SYSTEM = NON-STRUCTURAL COMPONENT - R_po = 1.5 / C_AR = 1.0 3. GEOTECHNICAL INFORMATION - ALLOWABLE BEARING PRESSURE = 1,500 PSF USED FOR EQUIPMENT FOUNDATION 4. SNOW LOAD - GROUND SNOW LOAD = 0 PSF ENLARGED STRUCTURAL SITE PLAN 3/16" = 1'-0" N S EW SITE LEGEND 0 1'12'8'4' NOTES: 1. PAD EXTENTS AND FOOTING TO BE CONFIRMED BY CONTRACTOR PRIOR TO CONSTRUCTION. 2. SWITCHBOARD DIMENSIONS AND ANCHOR LOCATIONS ARE LIABLE TO CHANGE. CONTRACTOR TO VERIFY AGAINST VENDOR FINAL SHOP DRAWINGS. 3. UTILITY EQUIPMENT/FOUNDATION DIMENSIONS AND LOCATIONS PER UTILITY. CONTRACTOR TO VERIFY AGAINST EXECUTED UTILITY DESIGN. 4. UTILITY BOLLARDS PER UTILITY REQUIREMENTS. CONTRACTOR TO VERIFY AND COORDINATE WITH UTILITY ON LOCATION, QUANTITY, AND SPECS. (N) SUPERCHARGER POST (E) PROPERTY LINE (N) FIXED BOLLARD (N) CONCRETE CURB (N) EV MINI REBOUNDING BOLLARD SIGN (N) CONCRETE PAVING (N) UTILITY BOLLARD (N) POLE-MOUNTED LIGHT FIXTURE (N) EV MINI REBOUNDING BOLLARD (N) FULL DEPTH ASPHALT 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B B U I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 9 2 7 0 5 , U S ENLARGED SITE PLAN S-301 REV: B IFP MHANNOUNPLOT DATE: 4/22/2026 11:39 AM JB-9275533-00 Ơ TE S L A S U P E R C H A R G E R _ S A N T A A N A , C A 16 S U P E R C H A R G E R S B B B Yoo Jin Kim Digitally signed by Yoo Jin Kim Date: 2026.04.22 11:32:31 -07'00' CONCRETE DESIGN 1. ALL CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE ACI. 2. CONCRETE SHALL BE NORMAL WEIGHT AND SHALL HAVE 2,500 PSI STRENGTH AT 28 DAYS. 3. REINFORCED CONCRETE IN THE FOUNDATION SHALL BE OF NATURAL AGGREGATE CONFORMING TO ASTM C-33. 4. TYPE I/II CEMENT TO MEET ASTM C150. 5. REINFORCING STEEL - ASTM A615 WITH THE FOLLOWING STRENGTHS: SIZE STRENGTH: #4 AND SMALLER GRADE 60 (fy = 60000 PSI) #5 AND LARGER GRADE 60 (fy = 60000 PSI) 6. FABRICATE AND PLACE REINFORCEMENT IN ACCORDANCE WITH ACI PUBLICATION SP-66, ACI DETAILING MANUAL - LATEST EDITION. 7. PLACE CONCRETE IN COMPLIANCE WITH ACI 304. ALL CONCRETE SHALL BE MECHANICALLY VIBRATED. 8. CONFORM TO ASTM C-94 FOR CONCRETE MIXING OPERATIONS. 9. CONCRETE COVER FOR REINFORCEMENT FOR NON-PRESTRESSED, CAST IN PLACE CONCRETE SHALL BE AS FOLLOWS: CONDITION COVER CAST AGAINST EARTH 3" EXPOSED TO WEATHER #5 AND SMALLER 1-1/2" #6 AND LARGER 2" SLAB-ON-GRADE 2" 10.EMBEDS -ALL ITEMS TO BE CAST INTO CONCRETE SUCH AS REINFORCING DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY AND ACCURATELY POSITIONED INTO THE FORMS PRIOR TO PLACING THE CONCRETE. 11. ALL CONCRETE EXPOSED TO THE WEATHER TO BE AIR ENTRAINED AND SHALL CONFORM TO ASTM C-260. 12.PROVIDE CONTINUOUS REINFORCING BARS UNLESS WHERE SPLICES ARE SPECIFICALLY SHOWN ON THE DRAWINGS. 13.CALCIUM CHLORIDE ADMIXTURES OR ADMIXTURES CONTAINING CHLORIDE SALTS SHALL NOT BE ADDED TO THE CONCRETE. FINISHED GRADE FOUNDATION AND ANCHORAGE PER EQUIPMENT PAD DETAIL A. S501.1453 SIMPLIFIED SWITCHBOARD DETAIL RA SWITCHBOARD NTS (N) ANCHOR LOCATION, (6) ANCHORS PER SECTION, TYP. 7'-7" MAX TYP SWITCHBOARD CABINET DESIGN TO BE VERIFIED AGAINST VENDOR DRAWINGS 2500 LBS MAX PER CABINET SECTION, TYP. CONDUIT WINDOW, TYP. 29.75" MIN. E C NTS (4) #4 TIES @ 3" SPACING O.C. AT TOP OF PIER (E) GRADE 2' MIN 12' MAX. (E) GRADE (N) LIGHT POLE, FIELD INSTALLED, DESIGNED BY OTHERS (VERIFY DIMENSIONS IN FIELD) 80 LBS MAX. #4 REBAR TIES AT 6" SPACING O.C. POLE BASE PLATE DESIGNED BY MANUFACTURER, INSTALLED BY TESLA CONTRACTOR 4" MAX. 33'' (8) #6 VERTICAL REBAR EQUALLY SPACED INSIDE TIES 3' MAX 3" MIN 5' MIN LIGHT POLE FOUNDATION MOTION AND PHOTOCELL SENSOR OPTIONAL JUNIPER ACCESS POINT (4 LBS) OPTIONAL CRADLEPOINT ANTENNA (2 LBS)25 LBS MAX FOR EACH LIGHT FIXTURE, FIELD INSTALLED, DESIGNED BY MANUFACTURER, INSTALLED BY TESLA CONTRACTOR OPTIONAL DOUBLE HEADANCHOR BOLT BY OTHERS PER POLE MANUFACTURER SPECIFICATIONS NTSS501.1433 PIPE BOLLARD DETAIL INSTALLATION DETAIL MASTER RA FIXED BOLLARD DETAIL (N) BOLLARD NOTES 1. 4" STD MIN PAINTED STEEL PIPE 2. FILL PIPE WITH CONCRETE 3. 36" MIN EMBEDMENT IN CONCRETE FOOTING 4. 18" MIN DIA CONCRETE FOOTING 5. SET POST NOT LESS THAN 36" ABOVE GRADE SLOPE TOP OF FOOTING (WHERE NOT SURROUNDED BY CONCRETE SLAB, OR WHERE IN EQUIPMENT WORK CLEARANCES) 36" MIN 18" MIN4-1/2" MIN 36" MIN FREE DRAINING CRUSHED ROCK FILL (MIN. 4-1/2") 3" MIN CLR F S501.1331 V3 SUPERCHARGER CABINET PLINTH DETAIL-ISO-ALL VIEWS RA V4 SUPERCHARGER CABINET CIP FOUNDATION 3/4"=1'-0" AC CONDUIT (SWITCHBOARD TO CABINET) ETHERNET CONDUIT (ETHER-LOOP) DC POST CONDUIT (CABINET TO POST) FOUNDATION AND ANCHOR DESIGN PER EQUIPMENT PAD DETAIL A. CONTRACTOR TO OBTAIN CONDUIT WINDOW TEMPLATE PRIOR TO COMMENCING CONSTRUCTION AND UTILIZE TEMPLATE WHEN LAYING OUT CABINETS FINISHED GRADE TOP VIEW FRONT VIEW 2420 LBS 2420 LBS 8 14"3'-2 18" 134" 258" 36" MIN. 3'-534" CABINET ANCHORAGE LOCATIONS, (TYP. 4) 2'-9"1078" PROVIDE 3.75" MIN. FROM ANCHORS TO CONDUIT WINDOW AND PAD EDGE FRONT 4'-634" 3'-1058" 6'-334" B 658" 2 14" 5258" V4 CABINET CONDUIT WINDOW DETAIL 3/4" = 1' - 0" 658" CABINET ENCLOSURE AC CONDUIT WINDOW 4" AC CONDUIT TYP. DC CONDUIT WINDOW4" DC CONDUIT TYP. SEE STRUCTURAL DETAIL FOR ANCHOR LOCATION NOTES: - DATUM LOCATED AT LEFT FRONT CORNER OF CABINET ENCLOSURE AS ORIGIN TO LOCATE CONDUIT WINDOWS - CONTRACTOR TO OBTAIN CONDUIT WINDOW TEMPLATE BEFORE STARTING CONSTRUCTION; USE FOR CABINET LAYOUT. 1638"1778"16"17 12" 4034" 1.25" COMMUNICATION CONDUIT 4338" HG E F DC B A 1.25" SPARE CONDUIT D A S511.107 FLAT EQUIPMENT PAD & ANCHOR SECTION RX EQUIPMENT PAD & ANCHOR SECTION (NO-SNOW) NTS 3" MIN. 6" MAX.FINISHED GRADE 12" MIN. 6" MIN EDGE DISTANCE* 10" 6" MIN. #5 REBAR CONTINUOUS 1/2" DIAMETER SS HILTI KB-TZ2 ANCHOR SYSTEM WITH 3-1/4" MIN. EMBEDMENT INTO (N) EQUIPMENT SLAB IN ACCORDANCE WITH ESR-4266, OR APPROVED EQUAL. 10" SLAB WITH #5 @ 16" O.C. EACH WAY AT CENTER OF SLAB NOTE: MAX. CONTINUOUS SLAB LENGTH SHOULD NOT EXCEED 50 FT W/O EXPANSION JOINT 6" MIN., 95% RELATIVE COMPACTED CLASS 2 AGGREGATE BASE IN ORDER TO MAINTAIN POSITIVE DRAINAGE, TOP OF SLAB SHALL SLOPE BETWEEN 0.5% AND 2% IN THE DOWNHILL DIRECTION. * 3.75" MIN EDGE DISTANCE FOR V4 CABINET PRODUCT ONLY 9" 6" 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B B U I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 9 2 7 0 5 , U S STRUCTURAL DETAILS S-501 REV: B IFP MHANNOUNPLOT DATE: 4/22/2026 11:39 AM JB-9275533-00 Ơ TE S L A S U P E R C H A R G E R _ S A N T A A N A , C A 16 S U P E R C H A R G E R S B 134" 2" Yoo Jin Kim Digitally signed by Yoo Jin Kim Date: 2026.04.22 11:32:20 -07'00' V4 POST PLP FOUNDATION - FLUSH W/ CONCRETE BEHIND NTS PLP FOUNDATION BASE 11" 11"11" 6" 25" CABLE OR CONDUIT WINDOW (E) NATIVE SOIL C (N) CONCRETE (N) ASPHALT, REF TO DETAIL E/A-501 (E) ASPHALT PAVEMENT (N) ASPHALT JOINT, REF TO DETAIL F/A-501 6" MIN DEPTH & 11" MIN WIDTH ON ALL SIDES OF 95% COMPACTED CLASS 2 AGGREGATE 11" TOP VIEW BELOW PAVEMENT 3'-2" 4' ANGLED VIEW CABLE OR CONDUIT WINDOW FOUNDATION BASE 11" FRONT VIEW SIDE VIEW SEE SITE PLAN FOR EXTENTS OF ASPHALT REQUIRED (N) CONCRETE 6'-4 12" 2'-234" V4 TESLA SUPERCHARGER POST WEIGHT: 198 LBS TESLA SUPERCHARGER HANDLE (MAX. 48" HEIGHT FOR ACCESSIBLE CHARGE POSTS) NO OTHER EQUIPMENT OR FOUNDATION TO BE IN GRAVEL OFFSET PROVIDE 60% MIN. (16" FROM THE BOTTOM) FILL INSIDE WITH COMPACTED CLASS 2 AGGREGATE 95% COMPACTED CLASS 2 AGGREGATE TRAFFIC-RATED SMC LID (4) 5/8" DIA A307 HDG THROUGH BOLT AND WASHER EV MINI BOLLARD USING (3) 3/8" DIA A307 HDG THROUGH BOLT V4 SUPERCHARGER POST CAST-IN-PLACE FOUNDATION NTSS501.1369 CIP SINGLE POST FOUNDATION RA 334" 334" 2'-234" NATIVE SOIL (2) #5 CONTINUOUS REBAR AT T&B (N) CIP PAD FLUSH WITH (E) PAVEMENT NATIVE SOIL (E) GRADE @ ACCESSIBLE EV CHARGE POSTS BOLLARD W/OPTIONAL SIGN ANCHORS OPTIONAL EV MINI REBOUNDIN BOLLARD 6" 1'-6" V4 SUPERCHARGER POST (REAR VIEW) 9' 2' FRONT VIEW SIDE VIEW TOP VIEW 30° 6" 1'-6" 6" MIN. COMPACTED CLASS 2 AGGREGATE BASE (3) 1/2" DIA SS HILTI KWIK-BOLT TZ2 WITH 2.5" MIN EMBEDMENT AND MIN 4.5" FROM EDGE OF PAD V4 TESLA SUPERCHARGER POST WEIGHT: 198 LBS TESLA SUPERCHARGER HANDLE (MAX. 48" HEIGHT FOR ACCESSIBLE CHARGE POSTS) (N) V4 TESLA SUPERCHARGER POST #4 @ 12" O.C. V4 SERCHARGER POST (FRONT VIEW) (4) 1/2" DIA SS HILTI KWIK-BOLT TZ2 WITH 3.75" MIN. EMBEDMENT PER ESR-4266, OR (4) 1/2" DIA SS THREADED ROD WITH HILTI HIT-HY 200 V3 ADHESIVE ANCHOR SYSTEM WITH 4" EMBEDMENT PER ESR-4868, OR APPROVED EQUAL. 9' 1' 2' 5 12"4" MIN. 6'-4 12" 3'-6"2'3'-6" B TOP 9' 2" 11'-5" 6'-2 14"14'-10'' TYP. A SIDE S501.1460 V4 PSU FU - FISHBONE - METAL FOUNDATION DETAIL RA FRONT 6'-31316" 10"6" MIN. FINISHED GRADE FINISHED GRADE NTS V4 PRE-ASSEMBLED SUPERCHARGER FOLDING UNIT FISHBONE METAL DETAIL D - 4' MIN. SEE CUTSHEETS FOR ADDITIONAL INFORMATION. APPROXIMATE COMPONENT WEIGHTS: CABINET = 2,420 LBS POST = 198 LBS (EACH) LIGHT POLE + WIFI = 150 LBS MAX (EACH) METAL SKID = 6,700 LBS TOTAL UNIT WEIGHT: 11,004 LBS - SUPERCHARGER CABINET, CHARGEPOSTS, AND LIGHT POLES ARE ANCHORED WITH (4) 5/8'' DIAM. A325 GALV. THRU BOLTS INTO STRUCTURAL FRAMING OF METAL SKID. 12' MAX OPTIONAL WIFI SUPERKIT LIGHT POLE FIELD INSTALLED, DESIGNED BY OTHERS TOP OF PSU FLUSH WITH ADJACENT GRADE. POSITIVE DRAINAGE IN ALL DIRECTIONS REQUIRED. SEE GRADING PLAN.EV MINI REBOUNDING BOLLARD, TYP. OFFSET BOLLARD, TYP. V4 SUPERCHARGER CABINET CABINET SECTION OF METAL SKID 6" MIN 95% RELATIVE COMPACTED CLASS 2 AGGREGATE BASE. METAL SKID SHALL MAINTAIN A CROSS SLOPE OF 1-2% AND A LONGITUDINAL SLOPE OF 0-5% METAL SKID NATIVE SOIL SUPERCHARGER HANDLE (2) OPTIONAL TRASH/RECYCLE BIN, WITH (4) 0.5" DIAM. THRU BOLTS TO SKID TOP PLATE V4 SUPERCHARGER POST, TYP. 8 D PSU WITH NO BALLASTING NTS NOTE: NO BALLAST IS REQUIRED FOR DESIGN WIND SPEED (3 SEC. GUST) 113 MPH MAX. FOR SKID WITH LIGHT POLES AND 117 MPH FOR SKID WITHOUT LIGHT POLES & DESIGN SEISMIC ACCELERATION, Sds = 2.5 MAX. WING AND FOLDING SECTIONS OF METAL SKID WIREWAY OPENING, TYP. S501.1414 V4 PSU FU - METAL FOUNDATION BALLASTING RA E 560009 PAYMENT KIOSK PLP FOUNDATION NTS SIDE VIEWFRONT VIEW 25" 18" 11"11" 25" 6" 11" 11" 18" 11" 6" MIN DEPTH & 11" MIN WIDTH ON ALL SIDES OF 95% COMPACTED CLASS 2 AGGREGATE (E) NATIVE SOIL (4) 3/8" DIA GALVANIZED THROUGH BOLT. CONDUIT WINDOW PROVIDE 60% MIN. (16" FROM THE BOTTOM) FILL INSIDE WITH COMPACTED CLASS 2 AGGREGATE (N) CONCRETE PAVEMENT, REF WALKWAY PAVEMENT DETAIL TOP VIEW BELOW PAVEMENT ANGLED VIEW CONDUIT WINDOW FOUNDATION BASE TRAFFIC-RATED SMC LID 95% COMPACTED CLASS 2 AGGREGATEGRAVEL BELOW PAVEMENT 18"18"11" (N) CONCRETE PAVEMENT, REF WALKWAY PAVEMENT DETAIL (E) NATIVE SOIL PLP FOUNDATION BASE6" 3'-5"3'-4" (N) TESLA PAYMENT KIOSK PAYMENT DEVICE (MAX. 48" HEIGHT FOR ACCESSIBLE CHARGE POSTS) 6.8" TESLA KIOSK WEIGHT : 31LBS (N) INSET SIGNAGE 3.68" AC/DC CONDUIT WINDOWS IN PSU TO MATCH (OR EXCEED) CABINET'S, REF. CABINET DETAIL DC AC 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B B U I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 9 2 7 0 5 , U S STRUCTURAL DETAILS S-502 REV: B IFP MHANNOUNPLOT DATE: 4/22/2026 11:39 AM JB-9275533-00 Ơ TE S L A S U P E R C H A R G E R _ S A N T A A N A , C A 16 S U P E R C H A R G E R S Yoo Jin Kim Digitally signed by Yoo Jin Kim Date: 2026.04.22 11:32:11 -07'00' 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B B U I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 9 2 7 0 5 , U S CUTSHEETS S-601 REV: B IFP MHANNOUNPLOT DATE: 4/22/2026 11:39 AM JB-9275533-00 TE S L A S U P E R C H A R G E R _ S A N T A A N A , C A 16 S U P E R C H A R G E R S B REFERENCE ONLY ! ! ! EN G I N E E R I N G D E S I G N S U R V E Y SITE VICINITY MAP SI T E N A M E : Sa n t a A n a , C A - 2 5 2 5 Gr a n d A v e ! 9047 LICENSED L A N D SURVEYOR STATE OF C A L IFORNIA MICHAEL E DAUST RE YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs EV CHARGING ONLY NO PARKING EV CHARGING ONLY TESLA SUPERCHARGER SANTA ANA, CA - 2525 NORTH GRAND AVENUE 16 SUPERCHARGERS APN: 396-361-05 PROJECT TEAM ELECTRICAL ENGINEER OF RECORD: ALEX SHORTS 10430 SHADY TRAIL #108 DALLAS, TX, 75220 (805) 663-3810 ASHORTS@CRAFTINGEDEN.COM APPLICABLE CODES 2025 CALIFORNIA BUILDING CODE 2025 CALIFORNIA ELECTRICAL CODE 2025 CALIFORNIA FIRE CODE 2025 CALIFORNIA ENERGY CODE SHEET INDEXDESIGN CRITERIA TRT: 458525 SYSTEM SUMMARY SUPERCHARGER SYSTEM SUMMARY EQUIPMENT QTY V4 SUPERCHARGER CABINETS (NON-PSU)1 V4 SUPERCHARGER POSTS (NON-PSU)8 V4 PSU FU (PRE-ASSEMBLED SUPERCHARGER UNIT)1 UTILITY TRANSFORMER 1 SWITCHBOARD 1 LIGHT POLES 3 N S EW AC ALTERNATING CURRENT ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISH FLOOR BLDG BUILDING CLR CLEAR COMM COMMUNICATION CONC CONCRETE DC DIRECT CURRENT DIA DIAMETER DIST DISTANCE (E)EXISTING EA.EACH EGC EQUIPMENT GROUNDING CONDUCTOR EMT ELECTRICAL METALLIC TUBING EQ EQUAL ERMS ENERGY REDUCTION MAINTENANCE SETTINGS ESS ENERGY STORAGE SYSTEM EV ELECTRIC VEHICLE GAB GRADED AGGREGATE BASE GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GFP GROUND FAULT PROTECTOR GND GROUND HVAC HEATING, VENTILATION, & AIR CONDITIONING I CURRENT IMP CURRENT AT MAX POWER INV INVERTER ISC SHORT CIRCUIT CURRENT KVA KILOVOLT AMPERE KW KILOWATT KWH KILOWATT-HOUR LOS LINE OF SIGHT LSIG LONG TIME, SHORT TIME, INSTANTANEOUS GROUND LV LOW-VOLTAGE LVDC LOW VOLTAGE DIRECT CURRENT MAX MAXIMUM MIN MINIMUM MV MEDIUM-VOLTAGE (N)NEW NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NRTL NATIONALLY-RECOGNIZED TESTING LABORATORY NTS NOT TO SCALE OC ON CENTER PCC POINT OF COMMON COUPLING PL PROPERTY LINES PLC POWER LINE COMMUNICATION POE POWER OVER ETHERNET PP POWERPACK PSU PRE-ASSEMBLED SUPERCHARGER UNIT PV PHOTOVOLTAIC PVC POLYVINYL CHLORIDE RSD RAPID SHUTDOWN SCCR SHORT CIRCUIT CURRENT RATING SCH SCHEDULE SQ. IN.SQUARE INCHES SS STAINLESS STEEL SSBJ SUPPLY SIDE BONDING JUMPER SSD SEE STRUCTURAL DRAWINGS STC STANDARD TESTING CONDITIONS TYP TYPICAL UON UNLESS OTHERWISE NOTED VIF VERIFY IN FIELD W WATT ABBREVIATIONS PROJECT SCOPE 1.WIND DESIGN -DESIGN WIND SPEED = 95 MPH -RISK CATEGORY = II -WIND EXPOSURE = C 2.SEISMIC DESIGN -RISK CATEGORY = II -SEISMIC IMPORTANCE FACTOR = 1.0 -SITE CLASS = D -Ss = 1.51 / S1 = 0.5 -Sds = 1.19 / Sd1 = 0.8 -SEISMIC DESIGN CATEGORY = D -BASIC SEISMIC-FORCE-RESISTING SYSTEM = NON-STRUCTURAL COMPONENT -R_po = 1.5 / C_AR = 1.0 3.GROUND SNOW LOAD = 0 PSF SITE LAYOUT AERIAL MAP REFERENCED DOCUMENTS TOPOGRAPHIC SURVEY UTILITY DESIGN STRUCTURAL ENGINEER OF RECORD: YOO JIN KIM TESLA, INC. 129 GERBERA STREET, DANVILLE, CA 94506 M:(949)285-6177 YOKIM@TESLA.COM CIVIL ENGINEER OF RECORD: MICHAEL P. HENDERSON TESLA, INC. 3500 DEER CREEK RD, PALO ALTO, CA 94304 M:(678) 687-1976 MIHENDERSON@TESLA.COM INSTALLATION OF SUPERCHARGERS AND NEW FU PSU (PRE-ASSEMBLED SUPERCHARGER UNIT), ASSOCIATED AC AND DC EQUIPMENT. INSTALLATION OF PRECAST, PRE-FABRICATED & CONCRETE EQUIPMENT PADS AND WALKWAYS. INSTALLATION OF NEW PARKING STRIPING, SIGNAGE AND ADA ACCESS FEATURES. ASPHALT OVERLAY FOR PROPOSED EV ADA STALLS. INSTALLATION OF NEW LED LIGHTING. PROJECT DESIGNER: MUSTAFA HANNOUN TESLA, INC. 1 TESLA RD., AUSTIN, TX 78725 (972) 369-4534   MHANNOUN@TESLA.COM ALL EXISTING AND PROPOSED LOCATIONS ARE BASED OFF THE SURVEYOR'S ESTABLISHED BENCHMARK AND CONTROL. IMPORTANT NOTE: PARKING STALL SCHEDULLE EXISTING STANDARD STALLS UTILIZED AS A RESULT OF THIS PROJECT 21 PROPOSED TESLA STALLS 16 PROPOSED STANDARD STALLS 0 AB1100 EV VAN CREDIT 1 NET STALL COUNT -4 EV CHARGE STALLS PROPOSED 16 ADA EV STALL TYPE CAR VAN AMBULATORY STALLS REQUIRED 1 1 0 STALLS PROPOSED 1 1 0 BASED ON CBC TABLE 11B-228.3.2.1 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S COVER PAGE G-001 REV: B IFP MHANNOUNPLOT DATE: 4/22/2026 11:31 AM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S N S EW AREA OF WORK N S EW NO R T H G R A N D A V E N U E SHEET #SHEET TITLE G-001 COVER PAGE G-002 NOTES G-100 OVERALL SITE PLAN G-101 DEMOLITION PLAN E-101 ELECTRICAL SITE PLAN E-201 SINGLE LINE DIAGRAM E-501 ELECTRICAL DETAILS E-502 ELECTRICAL DETAILS E-601 UTILITY DESIGN PLAN E-701 TITLE 24 A-301 ACCESSIBLE PARKING PLAN B BB EV CHARGING ONLY NO PARKING EV CHARGING ONLY TESLA SUPERCHARGER SANTA ANA, CA - 2525 NORTH GRAND AVENUE 16 SUPERCHARGERS APN: 396-361-05 PROJECT TEAM ELECTRICAL ENGINEER OF RECORD: ALEX SHORTS 10430 SHADY TRAIL #108 DALLAS, TX, 75220 (805) 663-3810 ASHORTS@CRAFTINGEDEN.COM APPLICABLE CODES 2025 CALIFORNIA BUILDING CODE 2025 CALIFORNIA ELECTRICAL CODE 2025 CALIFORNIA FIRE CODE 2025 CALIFORNIA ENERGY CODE SHEET INDEXDESIGN CRITERIA TRT: 458525 SYSTEM SUMMARY SUPERCHARGER SYSTEM SUMMARY EQUIPMENT QTY V4 SUPERCHARGER CABINETS (NON-PSU)1 V4 SUPERCHARGER POSTS (NON-PSU)8 V4 PSU FU (PRE-ASSEMBLED SUPERCHARGER UNIT)1 UTILITY TRANSFORMER 1 SWITCHBOARD 1 LIGHT POLES 3 N S EW AC ALTERNATING CURRENT ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISH FLOOR BLDG BUILDING CLR CLEAR COMM COMMUNICATION CONC CONCRETE DC DIRECT CURRENT DIA DIAMETER DIST DISTANCE (E)EXISTING EA.EACH EGC EQUIPMENT GROUNDING CONDUCTOR EMT ELECTRICAL METALLIC TUBING EQ EQUAL ERMS ENERGY REDUCTION MAINTENANCE SETTINGS ESS ENERGY STORAGE SYSTEM EV ELECTRIC VEHICLE GAB GRADED AGGREGATE BASE GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GFP GROUND FAULT PROTECTOR GND GROUND HVAC HEATING, VENTILATION, & AIR CONDITIONING I CURRENT IMP CURRENT AT MAX POWER INV INVERTER ISC SHORT CIRCUIT CURRENT KVA KILOVOLT AMPERE KW KILOWATT KWH KILOWATT-HOUR LOS LINE OF SIGHT LSIG LONG TIME, SHORT TIME, INSTANTANEOUS GROUND LV LOW-VOLTAGE LVDC LOW VOLTAGE DIRECT CURRENT MAX MAXIMUM MIN MINIMUM MV MEDIUM-VOLTAGE (N)NEW NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NRTL NATIONALLY-RECOGNIZED TESTING LABORATORY NTS NOT TO SCALE OC ON CENTER PCC POINT OF COMMON COUPLING PL PROPERTY LINES PLC POWER LINE COMMUNICATION POE POWER OVER ETHERNET PP POWERPACK PSU PRE-ASSEMBLED SUPERCHARGER UNIT PV PHOTOVOLTAIC PVC POLYVINYL CHLORIDE RSD RAPID SHUTDOWN SCCR SHORT CIRCUIT CURRENT RATING SCH SCHEDULE SQ. IN.SQUARE INCHES SS STAINLESS STEEL SSBJ SUPPLY SIDE BONDING JUMPER SSD SEE STRUCTURAL DRAWINGS STC STANDARD TESTING CONDITIONS TYP TYPICAL UON UNLESS OTHERWISE NOTED VIF VERIFY IN FIELD W WATT ABBREVIATIONS PROJECT SCOPE 1.WIND DESIGN -DESIGN WIND SPEED = 95 MPH -RISK CATEGORY = II -WIND EXPOSURE = C 2.SEISMIC DESIGN -RISK CATEGORY = II -SEISMIC IMPORTANCE FACTOR = 1.0 -SITE CLASS = D -Ss = 1.51 / S1 = 0.5 -Sds = 1.19 / Sd1 = 0.8 -SEISMIC DESIGN CATEGORY = D -BASIC SEISMIC-FORCE-RESISTING SYSTEM = NON-STRUCTURAL COMPONENT -R_po = 1.5 / C_AR = 1.0 3.GROUND SNOW LOAD = 0 PSF SITE LAYOUT AERIAL MAP REFERENCED DOCUMENTS TOPOGRAPHIC SURVEY UTILITY DESIGN STRUCTURAL ENGINEER OF RECORD: YOO JIN KIM TESLA, INC. 129 GERBERA STREET, DANVILLE, CA 94506 M:(949)285-6177 YOKIM@TESLA.COM CIVIL ENGINEER OF RECORD: MICHAEL P. HENDERSON TESLA, INC. 3500 DEER CREEK RD, PALO ALTO, CA 94304 M:(678) 687-1976 MIHENDERSON@TESLA.COM INSTALLATION OF SUPERCHARGERS AND NEW FU PSU (PRE-ASSEMBLED SUPERCHARGER UNIT), ASSOCIATED AC AND DC EQUIPMENT. INSTALLATION OF PRECAST, PRE-FABRICATED & CONCRETE EQUIPMENT PADS AND WALKWAYS. INSTALLATION OF NEW PARKING STRIPING, SIGNAGE AND ADA ACCESS FEATURES. ASPHALT OVERLAY FOR PROPOSED EV ADA STALLS. INSTALLATION OF NEW LED LIGHTING. PROJECT DESIGNER: MUSTAFA HANNOUN TESLA, INC. 1 TESLA RD., AUSTIN, TX 78725 (972) 369-4534   MHANNOUN@TESLA.COM ALL EXISTING AND PROPOSED LOCATIONS ARE BASED OFF THE SURVEYOR'S ESTABLISHED BENCHMARK AND CONTROL. IMPORTANT NOTE: PARKING STALL SCHEDULLE EXISTING STANDARD STALLS UTILIZED AS A RESULT OF THIS PROJECT 21 PROPOSED TESLA STALLS 16 PROPOSED STANDARD STALLS 0 AB1100 EV VAN CREDIT 1 NET STALL COUNT -4 EV CHARGE STALLS PROPOSED 16 ADA EV STALL TYPE CAR VAN AMBULATORY STALLS REQUIRED 1 1 0 STALLS PROPOSED 1 1 0 BASED ON CBC TABLE 11B-228.3.2.1 PROPRIETARY AND CONFIDENTIAL ABCDEFGH MHANNOUNPLOT DATE: 4/23/2026 9:58 AM N S EW AREA OF WORK N S EW NO R T H G R A N D A V E N U E SHEET #SHEET TITLE G-001 COVER PAGE G-002 NOTES G-100 OVERALL SITE PLAN G-101 DEMOLITION PLAN E-101 ELECTRICAL SITE PLAN E-201 SINGLE LINE DIAGRAM E-501 ELECTRICAL DETAILS E-502 ELECTRICAL DETAILS E-601 UTILITY DESIGN PLAN E-701 TITLE 24 -SURVEY B B B ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ANY OTHER REGULATING AUTHORITIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK. PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FROM TESLA OF ANY DISCREPANCIES. ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT THE SUBCONTRACTORS SOLE EXPENSE. SUBCONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO TESLA FOR APPROVAL BEFORE MAKING ANY CHANGES. DEVIATION FROM PLANS BEFORE WRITTEN APPROVAL FROM TESLA PLACES LIABILITY ON THE SUBCONTRACTOR. ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, CONTRACTOR SHALL USE STANDARD CONSTRUCTION PRACTICES. ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT TO MATCH EXISTING FINISHES. ANY METAL SHAVINGS FROM SITE WORK SHALL BE CLEANED FROM ALL SURFACES WHERE OXIDIZED OR CONDUCTIVE METAL SHAVINGS MAY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE. APPROVALS FROM BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE DRAWINGS. NEW PAVEMENT INSTALLED AS PART OF THIS PROJECT SHALL MATCH EXISTING PAVEMENT SECTION. ASPHALT AND GAB DEPTHS SHALL BE MAINTAINED. GENERAL NOTES SUPERCHARGER NOTES 1.ALL CONDUIT FURNISHED AND INSTALLED BY CONTRACTOR. ALL WIRING FURNISHED BY TESLA AND INSTALLED BY CONTRACTOR. 2.ALL BUSHINGS AND WIRING INTERNAL OF PROPOSED SERVICE EQUIPMENT PROVIDED BY MANUFACTURER. ANY MODIFICATIONS SHALL REQUIRE ENGINEERING APPROVAL PRIOR TO ANY CHANGES BEING MADE. 3.ALL ALUMINUM(AI) CONDUCTORS TO RECEIVE ANTI-OXIDATION COATING DURING INSTALLATION. ALL OTHER CONDUCTORS ARE COPPER UNLESS OTHERWISE NOTED. 4.THE FOLLOWING CHARGING CABINETS AND THE CHARGING POSTS USED ON THIS PROJECT COMPLY WITH THE FOLLOWING STANDARDS: ·IEC 61851-23: 2014 / EN 61851-23: 2014 ·UL 2202: 2009(R2012) ·CAN CSA C22.2 NO. 107.1-01(R2011) 5.THE AFOREMENTIONED STANDARDS IDENTIFY THE REQUIREMENTS MET BY THE EQUIPMENT, INCLUDING BUT NOT LIMITED TO: ·PROTECTION AGAINST ELECTRIC SHOCK ·OVERLOAD AND SHORT CIRCUIT PROTECTION ·FAULT PROTECTION ·DEGREES OF PROTECTION AGAINST ACCESS TO HAZARDOUS LIVE PARTS ·THE INTERNAL COMPONENTS OF THE SYSTEM ARE PROPRIETARY. ANY QUESTIONS CONCERNING ACTUAL INTERNAL PROTECTIVE DEVICES MUST BE COORDINATED DIRECTLY WITH TESLA. 6.TESLA SUPERCHARGER SIGNAL WIRING RATED 1000V AND USED FOR POWER LIMITED CLASS 1 CIRCUITS SHALL BE PERMITTED TO RUN IN CONDUITS, CABLE TRAYS, WIRE WAYS, OR RACEWAYS ALONG WITH ASSOCIATED DC CONDUCTORS AS ALLOWED PER NEC 725.48(B)(1) AND 620.36. 7.SUPERCHARGER CABINET AC CONDUCTORS SIZED UNDER ENGINEERING SUPERVISION USING THERMAL MODELING SOFTWARE. SPECIFICATIONS ABOUT THE TRENCHING REQUIREMENTS ARE SHOWN IN E-501 8.FOR DC RUNS IN EXCESS OF 330 FEET, CONTACT TESLA. 9.UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC OR UL LISTED HDPE. THE ABOVEGROUND PORTION OF AN UNDERGROUND/ABOVEGROUND TRANSITION SHALL BE SCHEDULE 80 PVC OR UL LISTED HDPE. 10.ABOVEGROUND CONDUITS EXPOSED TO VEHICULAR OR EQUIVALENT PHYSICAL DAMAGE SHALL BE RMC. ABOVEGROUND CONDUITS NOT EXPOSED TO VEHICULAR OR EQUIVALENT DAMAGE SHALL BE PERMITTED TO BE EMT. 11.WIRE SPLICES ARE NOT PERMITTED TO EXTEND WIRE RUN LENGTH. CONTRACTOR IS RESPONSIBLE FOR RERUNNING FULL LENGTH OF WIRE IF RUN LENGTH IS MISCALCULATED. 12.SPECIAL INSPECTION IS REQUIRED FOR ALL POST-INSTALLED CONCRETE ANCHORS. 13.PLANT GUARANTEE: CONTRACTOR SHALL GUARANTEE ALL PLANTS FOR A PERIOD OF ONE (1) YEAR FROM DATE OF PROJECT ACCEPTANCE BY THE OWNER. CONTRACTOR IS RESPONSIBLE FOR PLANT MAINTENANCE FOR THE FIRST GROWING SEASON. 14.IF EXISTING GRASS IS DAMAGED/REMOVED DURING CONSTRUCTION, CONTRACTOR SHALL APPLY SEED PER HYDROSEED METHOD. RATING OF SEED SHALL BE PER DISTRIBUTOR BASED ON SPECIES TYPE. 15.CONTRACTOR SHALL MATCH EXISTING LANDSCAPE; USE GRASS, RIVER ROCK, MULCH ETC. TO MATCH EXISTING LANDSCAPE AROUND EQUIPMENT, UNLESS OTHERWISE NOTED. 16.CONTRACTOR TO INSTALL WEED BARRIER IN FRONT OF SUPERCHARGER CABINETS AND SWITCHBOARD. BARRIER TO EXTEND FULL WIDTH AND DEPTH OF NEC REQUIRED WORKING CLEARANCES. GENERAL NOTES 1.ALL ELECTRICAL WORK SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE AS AMENDED BY APPLICABLE STATE AND LOCAL CODES. 2.ALL WIRING SHALL BE MANAGED IN A PROFESSIONAL, WORKMAN-LIKE MANNER AND MUST BE SUPPORTED, SECURED, AND PROTECTED TO PREVENT DAMAGE. 3.AC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER ART 210.5 OR 215.12. UNLESS OTHERWISE REQUIRED BY ART 210.5(1) OR AHJ, COLOR-CODING OF POWER CONDUCTORS SHALL BE AS FOLLOWS: CONDUCTOR 277/480V 120/208V PHASE A BROWN BLACK PHASE B ORANGE RED PHASE C YELLOW BLUE NEUTRAL GRAY WHITE 4.DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED PER ART 210.5 OR 215.12: CONDUCTOR STD COLOR ALT COLOR DC+RED RED-STRIPED DC-BLACK BLACK-STRIPED 5.TERMINATIONS OF AC, DC, AND COMMUNICATIONS CONDUCTORS SHALL BE PROFESSIONALLY AND LEGIBLY LABELED WITH CIRCUIT SCHEDULE IDENTIFIER, CONDUCTOR SIZE (AS APPLICABLE) AND TERMINATION TORQUE. 6.ALL EQUIPMENT SHALL BE LISTED BY A NRTL IN COMPLIANCE WITH ART 110.3. WHERE EXISTING NRTL LISTING CANNOT BE MAINTAINED, ENGINEERING APPROVAL SHALL BE OBTAINED PRIOR TO EQUIPMENT MODIFICATION, AND THE EQUIPMENT SHALL BE RELISTED BY A SUITABLE NRTL. 7.UNDERGROUND CONDUCTORS & CABLES TO BE INSTALLED IN CONDUIT UON. 8.ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NRTL LISTING. 9.REFER TO MANUFACTURER'S CURRENT PLANNING AND INSTALLATION MANUAL FOR TORQUE SPECS FOR ALL BOLTS AND TERMINAL CONNECTIONS. 10.ALL CONDUCTOR TERMINATIONS ON BUSSING OR TRANSFORMER SPADES SHALL BE MADE WITH HIGH-PRESS CRIMP LUGS UON. 11.ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE PROPERLY INSTALLED WITH BEST PRACTICES INCLUDING BUT NOT LIMITED TO: ·USE OF TERMINATION EQUIPMENT RATED FOR ALUMINUM AT THE CONDUCTOR TEMPERATURE, CURRENT, AND VOLTAGE ·ALLOWANCE FOR MOVEMENT DUE TO THERMAL EXPANSION/CONTRACTION ·PROPER COATING OF EXPOSED ALUMINUM WITH ANTI-OXIDIZATION COMPOUND ·USE OF CALIBRATED DEVICES TO TORQUE AND MARK TERMINALS TO REQUIRED SETTINGS 12.DUCT SEAL COMPOUND SHALL BE APPLIED WHEREVER CONDUITS TRANSITION INDOOR/OUTDOOR OR UNDERGROUND/ABOVEGROUND. REFER TO EQUIPMENT NOTES FOR ADDITIONAL DUCT SEAL REQUIREMENTS. 13.BELL ENDS SHALL BE INSTALLED WHEREVER CONDUIT ENTERS EQUIPMENT FROM UNDERGROUND AND WHEREVER POTENTIAL FOR DAMAGE TO CONDUCTORS IS PRESENT AT ANY POINT. BELL ENDS SHALL NOT PREVENT THE USE OF GROUNDING FITTINGS OR COUPLERS WHEN REQUIRED. 14.ALL STUB-UPS WITHIN FLOOR-MOUNTED EQUIPMENT SHALL BE 3-5" ABOVE FINISHED GRADE. 15.ALL CONDUITS EXPOSED TO VEHICULAR OR EQUIVALENT PHYSICAL DAMAGE SHALL BE RIGID GALVANIZED STEEL. 16.GROUND LUGS SHALL BE RATED FOR THEIR ENVIRONMENT AND CONDITION OF USE. ELECTRICAL NOTES SITE LEGEND (EXISTING OBJECTS)UTILITY SOUTHERN CALIFORNIA EDISON CATEGORY ITEMS TESLA UTILITY PRIMARY PRIMARY TRENCHING X INSTALL PRIMARY CONDUIT X INSTALL PULL ROPE X INSTALL PRIMARY FEEDERS X PROVIDE PRIMARY FEEDERS X PROVIDE ROAD CUTS / ROAD BORES X PAVEMENT REPLACEMENT X TRANSFORMER INSTALL TRANSFORMER PAD X PROVIDE TRANSFORMER X INSTALL TRANSFORMER X INSTALL CONNECTIONS - PRIMARY X INSTALL CONNECTIONS - SECD X SWITCHBOARD PROVIDE METER X INSTALL METER X LAND SECONDARY FEEDERS X SECONDARY SECONDARY TRENCHING X INSTALL SECONDARY CONDUIT X INSTALL PULL ROPE X INSTALL SECONDARY FEEDERS X PROVIDE SECONDARY FEEDERS X PROVIDE ROAD CUTS / ROAD BORES X PAVEMENT REPLACEMENT X SCOPE OF WORK UNDERGROUND SANITARY LINE CLEANOUT GREASE TRAP FIRE HYDRANT IRRIGATION CONTROL VALVE LIGHT POLE UTILITY POLE HANDICAP PARKING SIGN DECIDUOUS TREE PALM TREE SS UNDERGROUND ELECTRIC LINEUE OVERHEAD ELECTRIC LINEOE 17. THE GROUND-FAULT PROTECTION SYSTEM SHALL BE PERFORMANCE TESTED WHEN FIRST INSTALLED ON SITE. THIS TESTING SHALL BE CONDUCTED BY A QUALIFIED PERSON(S) USING A TEST PROCESS OF PRIMARY CURRENT INJECTION, IN ACCORDANCE WITH INSTRUCTIONS THAT SHALL BE PROVIDED WITH THE EQUIPMENT, A WRITTEN RECORD OF THIS TESTING SHALL BE MADE BE AVAILABLE TO THE AUTHORITY HAVING JURISDICTION. 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S NOTES G-002 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:55 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S EV CHARGING ONLY NO PARKING EV CHARGING ONLY (E) 90' R.O.W. DEDICATION (E) 20' BUILDING SETBACK (E) 6' ELECTRIC EASEMENT (E) PROPERTY LINE (E) 15' BUILDING SETBACK - E-101 (E) BUILDING (E) PARKING STRIPING, TYP (E) BUILDING OUTLINE (E) LANDSCAPE (E) CONCRETE GUTTER (E) 7'-5" CONCRETE WALKWAY 19' (N) 24'-1" DRIVE AISLE WIDTH (E) 30'-6" ENTRANCE/ EXIT WIDTH (E) 31'-9" ENTRANCE/ EXIT WIDTH 18' 27'-2"27'-3" 25'-6" 25'-7"25'-8"24' 24'-2" OVERALL SITE PLAN 1/32" = 1'-0" N S EW08'64'32'16' 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S OVERALL SITE PLAN G-100 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:55 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S NO R T H G R A N D A V E N U E 180 18 0 18 0 18 0 (E) WHEELSTOP, TYP. (E) BUILDING (E) CONCRETE WALKWAY, TYP. (E) CONCRETE CURB, TYP. (E) LANDSCAPE (E) ASPHALT (E) PILLAR, TYP. (E) PARKING STRIPING, TYP. (E) LIGHT POLE, TYP. (E) BUSINESS SIGN (E) 15' BUILDING SETBACK (E) POINT OF CONNECTION 4601932E (E) PROPERTY LINE (E) 27'-3" DRIVE AISLE WIDTH (N) 26'-7" DRIVE AISLE WIDTH (E) LIGHT POLE TO BE REMOVED (E) UNDERGROUND ELECTRIC LINE TO BE REROUTED AS NEEDED TO AVOID (N) EQUIPMENT FOUNDATIONS, REF. E-101 FOR EXTENTS (E) PORTION OF LANDSCAPE ISLAND TO BE REMOVED (E) STRIPING TO BE REMOVED, TYP. (E) ASPHALT TO BE REMOVED FOR INSTALLATION OF (N) ELECTRICAL EQUIPMENT PADS & (N) CONCRETE WALKWAY AT SHADED AREA. ASPHALT TO BE REPLACED AFTER INSTALLATION (E) ASPHALT TO BE REMOVED FOR INSTALLATION OF (N) BOLLARD FOUNDATION AT SHADED AREA. ASPHALT TO BE REPLACED AFTER INSTALLATION 8' 17'-4" (E) ASPHALT TO BE REMOVED FOR INSTALLATION OF TRENCHING AT SHADED AREA. ASPHALT TO BE REPLACED AFTER INSTALLATION OF TRENCHES 15'-9" (E) CONCRETE TO BE REMOVED FOR INSTALLATION OF TRUNCATED DOMES AT SHADED AREA. CONCRETE TO BE REPLACED AFTER INSTALLATION DEMOLITION PLAN 1/8" = 1'-0" N S EW ANY (E) OBJECT TO BE DEMOLISHED SITE LEGEND ANY (E) ELEMENT TO BE REMOVED THE CONTRACTOR SHALL REFER TO THE TRENCHING DETAILS ON THE ELECTRICAL DETAILS SHEET. THE LIMITS OF HARDSCAPE REMOVAL ARE SHOWN AS FOR INFORMATION ONLY AND IT SHALL BE UP TO THE CONTRACTOR TO DETERMINE THE EXACT LIMITS. NOTES HARDSCAPED AREA TO BE MODIFIED 0 1'16'4'8' 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S DEMOLITION PLAN G-101 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:55 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S NO R T H G R A N D A V E N U E B EV CHARGING ONLY NO PARKING EV CHARGING ONLY (E) WHEELSTOP, TYP. (E) BUILDING (E) CONCRETE WALKWAY, TYP. (E) CONCRETE CURB, TYP. (E) LANDSCAPE (E) ASPHALT (E) PILLAR, TYP. (E) PARKING STRIPING, TYP. (E) LIGHT POLE, TYP. (E) BUSINESS SIGN (E) 15' BUILDING SETBACK (E) POINT OF CONNECTION 4601932E 1A (N) PRE-ASSEMBLED SUPERCHARGER UNIT - (1) V4 CABINET, (8) POSTS & (1) ENCLOSED CIRCUIT BREAKER, PER STRUCTURAL (N) EV MINI REBOUNDING BOLLARD ACCESSIBLE SIGN, PER ARCHITECTURAL (N) 4’’ WHITE PARKING STRIPING, TYP. (N) CURB, TYP. PER ARCHITECTURAL (N) UTILITY BOLLARD, (TYP. 6), PROVIDED BY UTILITY, PER UTILITY DESIGN (N) FIXED BOLLARD, (TYP. 7), PER STRUCTURAL (N) EV MINI REBOUNDING BOLLARD, (TYP. 12), PER STRUCTURAL (N) ACCESSIBLE EV STALLS PER ARCHITECTURAL (N) 4’’ WIDE WHITE STRIPING WITH 4’’ WIDE WHITE CROSS STRIPING AT 36’’ O.C. (N) CONCRETE WALKWAY, PER ARCHITECTURAL (N) FULL DEPTH PAVING TO MATCH GRADE OF EXISTING SURROUNDING HARDSCAPE PROVIDE PAVING AS REQUIRED TO ACHIEVE 2% MAX SLOPE ALL DIRECTIONS AT ACCESSIBLE EV CHARGE STALLS AND ACCESS AISLE (E) PROPERTY LINE (N) RECYCLE/ TRASH BIN, PER ARCHITECTURAL PROPOSED ROUTE FOR (E) UNDERGROUND ELECTRICAL LINE TO AVOID (N) EQUIPMENT FOUNDATIONS 1B 1C 1D 1F 1G 1H2A2B2C2F2E2D2G2H 9'5'12'9' TYP. 18'-6"18'18' 18'-6"18' 9' TYP. 1E SPR-1 SPR-2 SB-1 LGT-1 LGT-2 WIFI AP-1 PSU-1 EVJB-1 XR-1 MTR CONSTRUCTION JOINT (N) HOUSEKEEPING PAD (N) 24'-1" DRIVE AISLE WIDTH (N) 25'-8" DRIVE AISLE WIDTH KIOSK-01 9' LGT-3 (N) TACTILE SURFACE TILE W/ TRUNCATED DOMES, PER ARCHITECTURAL ELECTRICAL SITE PLAN 1/8" = 1'-0" N S EW CHARGE POST FROM PAD EDGE 3' ON ALL SIDES AND 8' FROM FRONT (VERIFY WITH UTILITY STANDARDS) MINIMUM SERVICE CLEARANCES TRANSFORMER NOTES: UTILITY EQUIPMENT/FOUNDATION DIMENSIONS AND LOCATIONS PER UTILITY. CONTRACTOR TO VERIFY AGAINST EXECUTED UTILITY DESIGN. UTILITY BOLLARDS PER UTILITY REQUIREMENTS. CONTRACTOR TO VERIFY AND COORDINATE WITH UTILITY ON LOCATION, QUANTITY, AND SPECS. CONTRACTOR TO REFER TO EXECUTED UTILITY DESIGN FOR PRIMARY AND POINT OF CONNECTION DETAILS. FOR (N) ACCESSIBLE EV CHARGING AREA(S), CONTRACTOR TO FIELD VERIFY SLOPES ARE COMPLIANT PER ACCESSIBLE STALL DETAIL (REF. ARCHITECTURAL OR STRUCTURAL SHEETS). REGRADE AND ADD ASPHALT OVERLAY, NEW FULL DEPTH ASPHALT, AND/OR ASPHALT MILLING IF REQUIRED. EXISTING SPOT ELEVATIONS ARE APPROXIMATE PER SURVEY DATA AND ARE TO BE FIELD VERIFIED BY CONTRACTOR. SUPERCHARGER CABINET 2H POST TAG SIGN TYPE ACCESSIBLE CHARGING STALLS SCHEDULE 2 0 1'16'4'8' EXISTING STANDARD STALLS UTILIZED AS A RESULT OF THIS PROJECT 21 PROPOSED TESLA STALLS 16 PROPOSED STANDARD STALLS 0 AB1100 EV VAN CREDIT 1 NET STALL COUNT -4 PARKING STALL SCHEDULE 1'-6" 1' SERVICE SIDE CHARGE HANDLE5" SITE LEGEND (N) FIXED BOLLARD (N) CONCRETE CURB (N) EV MINI REBOUNDING BOLLARD SIGN (N) CONCRETE PAVING (N) CONDUIT ROUTE, SHOWN FOR DIAGRAMMATIC PURPOSES ONLY. SWITCHBOARD 4' EQUIPMENT TAGS XR-# TRANSFORMER (PROVIDED BY UTILITY PER UTILITY DESIGN)WIFI WIFI BROADCAST UNIT MTR UTILITY METER (PROVIDED BY UTILITY PER UTILITY DESIGN) AP-#SUPPLEMENTARY ACCESS POINT #X SUPERCHARGER POST SPR-#SUPERCHARGER CABINET PRE-ASSEMBLED SUPERCHARGER UNIT PSU-# LGT-#LIGHT FIXTURE (N) POLE-MOUNTED LIGHT FIXTURE ACCESSIBLE PARKING SIGNS, PER ARCHITECTURAL VAN ACCESSIBLE (N) EV MINI REBOUNDING BOLLARD (N) FULL DEPTH ASPHALT EVJB-#EV JUNCTION BOX KIOSK-01 PAYMENT KIOSK V4 SUPERCHARGER CABINET 5'1'-6" 6" (N) UTILITY BOLLARD 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S ELECTRICAL SITE PLAN E-101 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:55 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S NO R T H G R A N D A V E N U E B C C 2500AF/3P 2500AT/3P 100% RATED AC-SPR TYP GFP 41,838 AFC NOTE: AFC CALCULATED ASSUMING 2000kVA TRANSFORMER, 5.75% IZ AND INFINITE AFC AT PRIMARY. 30AS/15AF/2P 6.1 (N) SUPERCHARGER SYSTEM TO CONTROLS COMPARTMENT 1" CONDUIT. INCLUDES (1) CAT6 CABLE, TYP. 8 (N) GROUND RODS SPR-2 SPR-1 COMMS COMMS 1600AF/3P 1600AT/3P 100% RATED 1600AF/3P 1600AT/3P 100% RATED HGFEDCBA CERTIFIED FIELD INSTALLED EQUIPMENT WIRING TO UTILITY (N) SECONDARY SERVICE CONDUCTORS, PROVIDED BY UTILITY (N) MAIN SWITCHBOARD "SB-1" 1 (N) UTILITY TRANSFORMER "XR-1" BY UTILITY 2 MS PS MS PS AC-LGT 15A/1P MS PS (N) LIGHT FIXTURE "LGT- 1" (N) LIGHT FIXTURE "LGT- 2" (N) LIGHT FIXTURE "LGT- 3" 7 C (N) ACCESS POINT "AP-1" 1" CONDUIT, TYP. 5 M 3 (N) UTILITY METER BY UTILITY ADDITIONAL PLACARDS REQUIRED FOR ARC FLASH LABELS PLACARDS TO BE MADE OF RED PHENOLIC PLASTIC W/ 1" WHITE LETTERING. ATTACH PLACARDS WITH RIVETS OR SELF-TAPPING SCREWS PLACARD NOTES: EQUIPMENT NOTES# LEGEND CIRCUIT BREAKER SWITCH FUSE CURRENT TRANSFORMER WYE TRANSFORMER WINDING GROUNDED WYE TRANSFORMER WINDING M METER POWER TRANSFORMER AC-DC OR DC-AC CONVERTER EQPT. ENCLOSURES BUSSING CONDUCTORS SHIELDED CAT6 CABLEC MS PS LIGHT WITH MOTION AND PHOTO SENSOR WIFI CONNECTION DELTA TRANSFORMER WINDING DELTA HIGH-LEG TRANSFORMER WINDING TESLA EV SYSTEM DISCONNECT SYSTEM PLACARDS ATTACH ON SWITCHBOARD MAIN DISCONNECT TESLA SUPERCHARGER 480/277, 3PH, 4W 2525 NORTH GRAND AVENUE SANTA ANA, CA 92705 ATTACH ON FRONT OF SWITCHBOARD WARNING CONTROLS COMPARTMENT EQUIPMENT IS STILL LIVE WHEN THE MAIN SERVICE DISCONNECT IS IN THE "OFF" POSITION. INDEPENDENT "CONTROLS DISCONNECT" LOCATED ADJACENT TO MAIN DISCONNECT ATTACH ON EXTERIOR OF CONTROLS COMPARTMENT PANEL AT SWITCHBOARD LOAD SCHEDULE SWITCHBOARD "SB-1" LOAD SCHEDULE CKT NO TRIP AMPS DESCRIPTION VOLT-AMPS VOLT-AMPS DESCRIPTION TRIP AMPS CKT NOABCABC 1 1,600 SUPERCHARGER #1 332,666 ----SUPERCHARGER #2 1,600 2 3 ""----""4 5 ""----""6 7 15 WIFI --8 9 10 TOTALS PHASE A B C APPARENT POWER 665 kVA CURRENT 2,400 A 200 ""-200 - 15- 332,666 332,666 332,666 332,666 332,666 665 kVA 2,400 A 665 kVA 2,400 A LIGHTING-288 AC CIRCUIT SCHEDULE CIRCUIT #CONDUCTOR METAL UON # OF CONDUITS # PHASE CONDUCTORS PER CONDUIT PHASE CONDUCTOR SIZE NEUTRAL CONDUCTOR SIZE EGC MAX CIRCUIT LENGTH WIRE TYPE CONDUIT TYPES MIN CONDUIT SIZE (IN) AC-SPR AL 5 3 750 KCMIL -350 KCMIL 600'XHHW-2 PVC, RMC, EMT, DIRECT 4 AC-LGT CU 1 1 12 AWG 12 AWG 12 AWG 150'THWN-2 PVC, RMC, EMT 1 DC-POST AL 1 4 600 KCMIL -AWG 4/0 (AL)330'XHHW-2 (1000V) PVC, RMC, EMT, HDPE, DIRECT 4 1 (N) UTILITY TRANSFORMER "XR-1" • SIZE & PRIMARY VOLTAGE PER UTILITY • SECONDARY 480Y/277V 2 (N) MAIN SWITCHBOARD "SB-1" • 480/277 VAC, 2500A • 2500A MAIN BREAKER, 100%-RATED, LSIG AND ERMS • 65 kAIC MIN. • NEMA 3R 3 (N) UTILITY METER • METER # TBD 4 (N) WIFI BROADCAST UNIT "WIFI" IN SWITCHBOARD • INTERNALLY FUSED IN CONTROLS COMPARTMENT • UNIT PRE-INSTALLED IN SWITCHBOARD • CRADLEPOINT # R1900 BROADCAST UNIT • CRADLEPOINT # RX30 POE SWITCH TO SUPPLY ACCESS POINT 5 (N) ACCESS POINT "AP-1" • JUNIPER # AP64 SUPPLEMENTARY ACCESS POINT FED FROM BROADCAST UNIT • COMES WITH ACCESSORY MOUNTING BRACKET • POWER OVER ETHERNET • REF STRUCTURAL DRAWINGS FOR GROUNDING • IP67 / NEMA 4 COMPLIANT • (1) TOTAL ACCESS POINT(S) 6.0 (N) V4 PSU PRE-ASSEMBLED SUPERCHARGER UNIT "PSU-1" • (1) SUPERCHARGER SYSTEM • FACTORY PRE-WIRED DC-POST • (1) PSU'S TOTAL 6.1 (N) SUPERCHARGER SYSTEM (1) V4 SUPERCHARGER CABINET "SPR-#" PER SYSTEM • COMMUNICATIONS COMPARTMENT INTEGRATED • 480VAC, 3PH, 3W • 1200A MAX AC INPUT • 65 kA SCCR (8) V4 SUPERCHARGER POSTS "DC" PER SYSTEM • 500KW MAX • 180 VDC - 1000 VDC CERTIFIED EQUIPMENT WIRING "DC-POST" FROM CABINET TO SUPERCHARGER POST • 1 SET PER CHARGE POST • (4) 600KCMIL AL (2POS, 2 NEG) • (1) 4/0AWG AL OR 2/0AWG CU EGC • 330' MAX CIRCUIT LENGTH • XHHW-2, 1000V RATED • MIN 4" CONDUIT (PVC, RMC, EMT OR HDPE) OR DIRECT BURIAL • (2) SUPERCHARGER SYSTEMS 7 (N) LIGHT FIXTURE "LGT-#" • WISCONSIN LIGHTING • NF-SLS-100-40-HV-3W-RAL-MPS • 96W, 277-480VAC DRIVER • INTEGRATED PHOTOCELL AND MOTION SENSOR • POLE MOUNTED • 4000K LIGHTING COLOR TEMPERATURE • RUGGED ALUMINUM CHASSIS • -40°C MIN REQUIRED AMBIENT TEMPERATURE (3) TOTAL FIXTURES 8 (N) GROUNDING ELECTRODE • SEE SHEET E-501 FOR GROUNDING DIAGRAM 6.0PSU-1 15SPARE 1" CONDUIT. INCLUDES: (1) CAT6 CABLE (N) PAYMENT KIOSK "KIOSK-01" 10 10 (N) TESLA PAYMENT KIOSK "KIOSK-01" • POWER OVER ETHERNET • (1) SET PER KIOSK • (1) CAT 6 CABLE • MAX. CIRCUIT LENGTH - 330FT C C C C 15A/1P SPARE --- C C WIFI BROADCAST UNIT "WIFI" CONTROLS COMPARTMENT (SWITCHBOARD-INTEGRATED) 3 POE SWITCH 9 9 (N) POE MANAGED SWTICH • CRADLEPOINT #RX30. CAN HAVE INTERNALLY COUPLED CONNECTION W/ CRADLEPOINT #R1900 • (OR) TELTONIKA #TSW202 • (OR) WAGO #852-1813/000-001 • INTERNALLY FUSED IN CONTROLS COMPARTMENT • UNIT PRE-INSTALLED IN SWITCHBOARD CIRCUIT #CONDUCTOR METAL UON # OF CONDUITS # POWER CONDUCTORS PER CONDUIT POWER CONDUCTOR SIZE EGC SIGNAL WIRE MAX CIRCUIT LENGTH WIRE TYPE CONDUIT TYPES MIN CONDUIT SIZE (IN) DC-POST AL 1 4 600 KCMIL AWG 4/0 (AL)TESLA PROVIDED 330'XHHW-2 (1000V) PVC, RMC, EMT, HDPE, DIRECT 4 DC CIRCUIT SCHEDULE HGFEDCBA DC-POST TYP 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S SINGLE LINE DIAGRAM E-201 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:55 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S NTS AC-SPR 24" MAX MAX RHO BACKFILL* CABLE SPACING (X) MIN INTER TRENCH SPACING (Y) 120 3"2'-6" 90 0"1'-9" 60 0"1'-3" (X) 4C 500 KCMIL AL + 1C 2/0 AWG AL PVC 600/1000V UL TRAY CABLE (DIRECT BURIAL RATED), INSULATED GROUND. (2) CABLES PER CHARGE CABINET. MAX. (8) CABLES PER GROUP. DETECTABLE RED WARNING TAPE. 8" BELOW THE SURFACE. PER TABLE (Y) * SEE TRENCHING NOTES. CABLE RUN IN A SINGLE ROW, CANNOT BE STACKED. "AC-SPR" CIRCUITS TRENCH - DIRECT BURIALF NTS "DC-POST" CIRCUITS TRENCH - DIRECT BURIAL DC-POST PER TABLE NO. OF POST CIRCUITS (MAX) MAX RHO BACKFILL*MAX DEPTH MIN DEPTH (VEHICULAR AREA) MIN DEPTH (NON-VEHICULAR AREA) 16 120 28"24"24" 24 90 28"24"24" 3" 4C 600 KCMIL AL + 2/0 AWG CU PVC 600/1000V UL TRAY CABLE (DIRECT BURIAL RATED), INSULATED GROUND. (1) CABLE PER CHARGE POST. MAX. (24) CABLES PER GROUP. DETECTABLE RED WARNING TAPE. 8" BELOW THE SURFACE. CABLES MAY NOT BE STACKED MORE THAN (2) HIGH. 3" 24" MIN BETWEEN GROUPS. * SEE TRENCHING NOTES. C NTS "AC-SPR" CIRCUITS TRENCH - 4" CONDUITS (1,200A) AC-SPR NO. OF CABINET CIRCUITS (MAX) MAX RHO BACKFILL*MAX DEPTH MIN DEPTH (VEHICULAR AREA) MIN DEPTH (NON-VEHICULAR AREA) 1 120 28"24"18" 2 90 28"24"18" 3 60 28"24"6" PER TABLE 4" CONDUIT, (5) CONDUITS PER CHARGE CABINET. MAX. (15) CONDUITS PER GROUP. NO SPACING BETWEEN CONDUITS IN THE BOTTOM LAYER, ALTERNATING CONDUITS REMOVED AS INDICATED IN THE TOP LAYER. DETECTABLE RED WARNING TAPE. 8" BELOW THE SURFACE. CONDUITS MAY NOT BE STACKED MORE THAN (2) HIGH.24" MIN BETWEEN GROUPS. * SEE TRENCHING NOTES. E NTS "DC-POST" CIRCUITS TRENCH - 4" CONDUITS DC-POST PER TABLE 4" CONDUIT, (1) CONDUIT PER CHARGE POST. MAX.(24) CONDUITS PER CONDUIT GROUP. DETECTABLE RED WARNING TAPE. 8" BELOW THE SURFACE. CONDUITS MAY NOT BE STACKED MORE THAN (2) HIGH. NO SPACING REQUIREMENTS BETWEEN CONDUITS. 24" MIN BETWEEN GROUPS. NO. OF POST CIRCUITS (MAX) MAX RHO BACKFILL*MAX DEPTH MIN DEPTH (VEHICULAR AREA) MIN DEPTH (NON-VEHICULAR AREA) 16 120 28"24"18" 24 60 28"24"6" * SEE TRENCHING NOTES. B TRENCHING NOTES ·THE TRENCH DESIGNS FOR ALL VEHICLE CHARGING CIRCUITS REQUIRING RHO VALUES ARE THE RESULT OF A THERMAL ANALYSIS OF THE CONDUCTORS UNDER LOAD. FOR PROPER PROTECTION THEY MUST BE FOLLOWED. ·APPROVED BACKFILL REQUIRES DOCUMENTATION THAT SPECIFIES TESTED RHO VALUE. USE THE SPECIFIED BACKFILL LISTED BELOW OR TEST NATIVE SOIL CONDITIONS TO CONFIRM MAX DEFINED RHO VALUES. MINIMUM 2" OF APPROVED BACKFILL COVERAGE AROUND CONDUITS REQUIRED. ·RHO 60 BACKFILL - CONCRETE BACKFILL WITH MIN 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI MUST BE USED TO ACHIEVE MAX RHO 60. ·RHO 90 BACKFILL - LOW STRENGTH FLUIDIZED THERMAL (SLURRY) BACKFILL WITH MIN 28 DAY COMPRESSIVE STRENGTH OF 150 PSI MUST BE USED TO ACHIEVE MAX RHO 90. ·RHO 120 BACKFILL - NATIVE SOILS/SAND. ·FOR TRENCHES WITH MIXED CIRCUIT TYPES, APPLY THE CONDUIT SPACING FOR THE CIRCUIT TYPE WITH THE LARGER SPACING REQUIREMENT. ·CONDUIT ARE PERMITTED TO HAVE GREATER COVER THAN SPECIFIED FOR SHORT DISTANCES WHERE REQUIRED TO CROSS UNDER (E) UTILITY LINES, TO ALLOW FOR NEC REQUIRED MIN RADIUS FOR CONDUIT TURN-UPS INTO PAD-MOUNTED EQUIPMENT, TO AVOID (E) OBSTRUCTIONS, ETC. ·OUTSIDE WALLS AND UNDERNEATH BOTTOM ROW OF CONDUIT SPACING REQUIRED FOR ALL CONFIGURATIONS. ·IF NO CONDUIT RACKS AVAILABLE, CONTRACTOR MAY USE HORIZONTAL AND VERTICAL CONDUITS OR STAKES TO ACHIEVE THE SPACING REQUIRED. NOTES: 1. DURALINE SMOOTH-COR FLEX CONDUIT HAS BEEN CERTIFIED AS PART OF TESLA’S SUPERCHARGER SYSTEM. 2. RELEVANT TESTING REPORTS ARE AVAILABLE UPON REQUEST. 3. DURALINE SMOOTH-COR FLEX TO BE UTILIZED AS DC-POST CONDUIT ONLY. 4. PVC TO BE UTILIZED FOR ALL 90-DEGREE TRANSITIONS. DURALINE SMOOTH-COR FLEX CONDUIT NTSE501.107 SMOOTH-COR FLEX CONDUIT DETAIL KEYLOCK STRIPS NO GLUE O-RING GASKET AIR & WATERTIGHT SEMI SMOOTH INNER WALL KEYLOCK COUPLING CORRUGATED OUTER WALL HIGH CRUSH STRENGTH O-RING GASKET AIR & WATERTIGHT KEYLOCK STRIPS NO GLUE CONDUIT CLAMP ADAPTER SMOOTH-COR FLEX DURALINE SMOOTH-COR FLEX TO SMOOTH-COR FLEX COUPLER DURALINE SMOOTH-COR FLEX TO HDPE, PVC, THREADED GALVANIZED STEEL A 24 " S U G G . DE P T H 18 " M I N . CO V E R 8" (E) GRADE (N) COMPACTED BACKFILL DETECTABLE RED WARNING TAPE APPROVED BACKFILL COMPACTED 95% PVC CONDUIT (REFER TO PLANS AND WIRE SCHEDULE FOR ACTUAL NUMBER AND LOCATION OF CONDUITS). E511.120 TRENCH - SOIL NON-TRAFFIC DETAIL RB TRENCH THROUGH SOIL NON-TRAFFIC NTSDE511.123 TRENCH - PAVEMENT TRAFFIC DETAIL RA TRENCH THROUGH PAVEMENT TRAFFIC NTS 30 " S U G G . D E P T H 24 " M I N . CO V E R 8" (E) ASPHALT/CONCRETE (N) FINISHED GRADE, REPAIR CAP TO MATCH EXISTING. RED WARNING TAPE APPROVED BACKFILL COMPACTED 95% PVC CONDUIT (REFER TO PLANS AND WIRE SCHEDULE FOR ACTUAL NUMBER AND LOCATION OF CONDUITS). G H NTS 12' MAX. (E) GRADE (N) LIGHT POLE, FIELD INSTALLED, DESIGNED BY OTHERS (VERIFY DIMENSIONS IN FIELD) 80 LBS MAX. POLE BASE PLATE DESIGNED BY MANUFACTURER, INSTALLED BY TESLA CONTRACTOR 4" MAX. POLE-MOUNTED ACCESS POINT MOTION AND PHOTOCELL SENSOR ARUBA ACCESS POINT (4 LBS) (OR OPTIONAL JUNIPER ACCESS POINT) OPTIONAL CRADLEPOINT ANTENNA (2 LBS)25 LBS MAX FOR EACH LIGHT FIXTURE, FIELD INSTALLED, DESIGNED BY MANUFACTURER, INSTALLED BY TESLA CONTRACTOR LISTED CONNECTION HANDHOLE GROUNDIND LUG WELDED TO INSIDE OF POLE AT HANDHOLE CAT6 1" CONDUIT W/ CAT6 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S ELECTRICAL DETAILS E-501 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:55 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S E501.100 REBAR UFER GROUNDING DETAIL RC NTS REBAR CAGE CONNECTED BY REBAR TIES CONCRETE EQUIPMENT PAD ATTACH GEC OR COMBINED GEC/EGC TO 20' OF CONTINUOUS OR SPLICED REBAR USING LISTED REBAR GROUNDING CONNECTOR GEC OR COMBINED GEC/EGC FROM GROUND BAR IN EQUIPMENT CONCRETE-ENCASED ELECTRODE FOR CAST-IN-PLACE PADS ONLYB G TO ADDITIONAL POSTS GN TO OTHER SUPERCHARGER CABINETS (N) SUPERCHARGER POST, TYP. NTS PSU GROUNDING DIAGRAM ·REFER TO ONE-LINE DIAGRAM FOR SPECIFIC CIRCUIT IDENTIFIERS BETWEEN EQUIPMENT. ·REFER TO AC & DC CIRCUIT SCHEDULES FOR NEUTRAL/GROUND SIZING PER CIRCUIT. NOTES LEGEND IRREVERSIBLE SPLICE OR CRIMP PER NEC 250.64(C) NEC 250.52(A)-COMPLIANT GROUNDING ELECTRODE PRIMARY OR SECONDARY COMMON TERMINAL, AS APPLICABLE G TERMINAL ON NEUTRAL OR GROUND BUSBAR N O NEUTRAL BUSBAR GROUND BUSBAR (N) SUPERCHARGER CABINET, TYP. GECS TO BE IRREVERSIBLY CRIMPED TOGETHER AT GROUNDING ELECTRODE (N) 3/0 CU GEC, SEE DETAIL B. (N) METAL PSU SKID, TYP. GN MAIN BONDING JUMPER (FACTORY-INSTALLED) TO UTILITY TRANSFORMER GROUNDED CONDUCTOR (NEUTRAL) AND CONNECTIONS PER UTILITY REQUIREMENTS (N) MAIN SERVICE EQUIPMENT (N) EGC, TYP. "AC-SPR" (N) 6 AWG BARE CU GEC (N) EGC, TYP. "DC-POST" FACTORY WIRED BREAKER SETTINGS MAIN SWITCHBOARD "SB-1", 1600AF/1200AT MCB - LINCOLN E. FRAME FRAME AMPS 1,600 MFR SCHNEIDER ELECTRIC TYPE MODEL MTZ TRIP UNIT SENSOR AMPS 1,600 PLUG AMPS 1,600 FUNCTIONS LSIG TYPE/MODEL MTZ1-L1 TRIP UNIT SETTINGS (1200A TRIP) LONG PICKUP lr (xln)1 (1600A) LONG TIME tr(s) @ 6xlr 3.5s SHORT PICKUP lsd (xlr)3(4800A) SHORT TIME tsd(s)0.1(l^s T OFF) INSTANTANEOUS PICKUP li (xln)3(4800A) GROUND FAULT PICKUP Ig (xln)0.6(960A) GROUND FAULT TIME tg (s)0.1(I^s T ON) INST OR FIXED 15560A A 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S ELECTRICAL DETAILS E-502 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:55 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S 1"12"0 PROPRIETARY AND CONFIDENTIAL ABCDEFGH 1 2 3 4 5 6 DA T E NO . RE V I S I O N ORIGINAL SIZE 24"X36" SHEET SIZE ARCH "D" 3500 DEER CREEK RD. PALO ALTO, CA 94304 (650) 681-5000 02 . 1 0 . 2 6 A 20 2 5 C O D E & O V E R A L L P L A N 03 . 2 3 . 2 6 B BU I L D I N G D E P A R T M E N T C O M M E N T 25 2 5 N O R T H G R A N D A V E N U E SA N T A A N A , C A 92 7 0 5 , U S UTILITY DESIGN PLAN E-601 REV: B IFP MCARMONADIAZPLOT DATE: 4/21/2026 2:55 PM JB-9275533-00   TE S L A S U P E R C H A R G E R _ SA N T A A N A , C A 16 S U P E R C H A R G E R S B B ! ! ! EN G I N E E R I N G D E S I G N S U R V E Y SITE VICINITY MAP SI T E N A M E : Sa n t a A n a , C A - 2 5 2 5 Gr a n d A v e ! 9047 LICENSED L A N D SURVEYOR STATE OF C A L IFORNIA MICHAEL E DAUST RE CITY OF SANTA ANA PUBLIC WORKS AGENCY 20 Civic Center Plaza ● M-22 Santa Ana, California 92702 www.santa-ana.org (714) 647-5659 May 2022 Page 1 of 2 PARKING LOT DEVELOPMENT PROJECTS WATER QUALITY MANAGEMENT PLAN (WQMP) REQUIREMENTS The purpose of this document is to assist property owners, developers, and project engineers with determining whether a parking lot project is subject to WQMP requirements. All parking lot projects are required to complete the WQMP checklist on page 2 of this document and submit it to the Public Works Agency prior to issuance of any permits. The City of Santa Ana owns and operates a Municipal Separate Storm Sewer System (MS4) and is subject to the requirements of the North Orange County Municipal NPDES Permit (Order No. R8-2009- 0030, as amended by Order No. R8-2010-0062). The NPDES Permit is issued to the City by the Regional Water Quality Control Board and contains various programs designed to protect water quality standards and reduce pollutants discharged in urban stormwater runoff. One such program is the New Development/Significant Redevelopment program, which requires the City to ensure that WQMPs are prepared for priority development projects, such as:  Parking lots 5,000 square feet or more including associated drive aisle, and potentially exposed to urban stormwater runoff. A parking lot is defined as a land area or facility for the temporary parking or storage of motor vehicles used personally, for business, or for commerce.  All significant redevelopment projects, where significant redevelopment is defined as the addition or replacement of 5,000 or more square feet of impervious surface on an already developed site. Redevelopment does not include routine maintenance activities that are conducted to maintain original line and grade, hydraulic capacity, original purpose of the facility, or emergency redevelopment activity required to protect public health and safety. Additional WQMP resources can be found below: Model WQMP and Technical Guidance Document (TGD): https://ocerws.ocpublicworks.com/service-areas/oc-environmental-resources/oc-watersheds/watershed- programs/water-quality City of Santa Ana Water Quality Ordinance (Chapter 18, Article IV of SAMC): https://library.municode.com/ca/santa_ana/codes/code_of_ordinances?nodeId=PTIITHCO_CH18HESA_A RTIVWAPO City of Santa Ana Stormwater Program: https://www.santa-ana.org/stormwater-management/ Orange County Stormwater Program: https://h2oc.org/ For additional information, please contact the City’s NPDES Manager at (714) 647-5659. CITY OF SANTA ANA PUBLIC WORKS AGENCY 20 Civic Center Plaza ● M-22 Santa Ana, California 92702 www.santa-ana.org (714) 647-5659 May 2022 Page 2 of 2 WATER QUALITY MANAGEMENT PLAN (WQMP) CHECKLIST Project Title and Address: Select the type of construction that applies to your parking lot project then follow the arrows to determine if the project is subject to WQMP requirements. Submit the completed checklist to the Public Works Agency. Construction of a new parking lot Addition or Redevelopment to an existing parking lot Enter surface area (square-feet) of new parking lot, including drive aisles, exposed to stormwater runoff in Box 1 below. sq-ft Does the project result in the addition of new impervious surface1 to the existing parking lot area (i.e. increased parking area)? Enter surface area (square-feet) of parking lot addition, including drive aisles, exposed to stormwater runoff in Box 2 below. Does the project consist of a “grind and overlay” and/or “slurry seal” treatment to the existing parking lot surface? sq-ft Is native soil2 being exposed, surface material changing (i.e. asphalt to concrete), or grade/drainage patterns changing? No WQMP Required3 No WQMP Required3 1 2 Enter surface area (square-feet) of redeveloped parking lot, including drive aisles, exposed to stormwater runoff in Box 3 below. sq-ft 3 1Impervious surface is a surface that prohibits stormwater infiltration into the ground 2Native soil is the soil below any existing engineered fill or base material 3Project is considered routine maintenance If the sum of the values entered into Box 1, 2, and 3 is greater than or equal to 5,000 square-feet, the project is subject to WQMP requirements and will require a grading permit. Public Works Agency – Development Engineering staff review and approve WQMPs and grading plans. Grading permits may also be required for routine maintenance projects, subject to the discretion of the Public Works Agency. I certify that the above information is true and accurate to the best of my knowledge. I am aware that City staff may conduct inspections of the project during construction and if staff determine the project is in fact subject to WQMP requirements, a Stop Work Order and/or Administrative Citation(s) with Administrative Fine(s) may be issued to the contractor and property owner, and a WQMP will be required for the project. Yes No Yes No Yes No Checkbox Checkbox Signature: Print Name: Date: Yes 2525 N Grand Ave, #MTR01 Aaron Wallen 5/14/26 N/A N/A N/A EQUIPMENT CONCRETE PAD / ANCHORAGE CALCULATIONS PROJECT: Tesla Supercharger - Santa Ana - Project # JB-9275533-00 2525 North Grand Avenu Santa Ana, CA 9270 REPORT PREPARED FOR: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 OWNER: Tesla Supercharger - Santa Ana 2525 North Grand Avenue Santa Ana, CA 92705 PROJECT DESIGNED BY: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 1 ASCE Hazards Report Address: No Address at This Location Standard:ASCE/SEI 7-22 Latitude:33.771093 Risk Category:II Longitude:-117.85117 Soil Class:D - Stiff Soil Elevation:182.16187516973102 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph 300-year MRI 89 Vmph 700-year MRI 95 Vmph 1,700-year MRI 102 Vmph 3,000-year MRI 106 Vmph 10,000-year MRI 115 Vmph 100,000-year MRI 133 Vmph 1,000,000-year MRI 151 Vmph Data Source: ASCE/SEI 7-22, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Thu Feb 12 2026 Page 1 of 5https://ascehazardtool.org/Thu Feb 12 2026 2 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-22 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Values for 10-year MRI, 25-year MRI, 50-year MRI and 100-year MRI are Service Level wind speeds, all other wind speeds are Ultimate wind speeds. Site is not in a hurricane-prone region as defined in ASCE/SEI 7-22 Section 26.2. Page 2 of 5https://ascehazardtool.org/Thu Feb 12 2026 3 PGA M : 0.66 SMS : 1.79 SM1 : 1.2 SDS : 1.19 SD1 : 0.8 T L : 8 SS : 1.51 S1 : 0.5 VS30 : 260 Seismic Design Category: D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE SpectrumR S (g) vs T(s)a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic D - Stiff SoilSite Soil Class: Results: Page 3 of 5https://ascehazardtool.org/Thu Feb 12 2026 4 Data Accessed: Thu Feb 12 2026 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-22 and ASCE/SEI 7-22 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-22 Ch. 21 are available from USGS. Page 4 of 5https://ascehazardtool.org/Thu Feb 12 2026 5 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 5 of 5https://ascehazardtool.org/Thu Feb 12 2026 6 1. Lateral Loads Calculation for Equipment (2025 CBC) 1.1 Earthquake Load Latitude =33.7711 Longitude =-117.8512 Soil Site Class =D Seismic Use Group =II From Spectrum Data: (from output of Seismic Design Parameters) SS =1.51 g SMS =1.79 g SDS = 2/3 SMS =1.193 g S1 =0.500 g SM1 =1.200 g SD1 = 2/3 SM1 =0.800 g Seismic Design Category =D  =1.0 (ASCE 7, 12.3.4.1) Seismic Design Force :(for Nonstructural Components) Rpo =1.5 CAR =1.0 (ASCE 7, Table 13.6-1) Ip =1.0 z/h =0.0 Ru =1.0 Supercharger_Cabinet_V4 Wp =2,420 lbs Fp = [0.4 SDS Ip Wp ((1+2.5(z/h) / Ru) (CAR/Rpo)(ASCE 7, 13.3-1) =770.1 lbs Fp,MAX = 1.6 SDS Ip Wp Fp,MIN = 0.3 SDS Ip Wp =4,620.6 lbs =866.4 lbs Therefore Fp =866 lbs Switchboard Wp =7,500 lbs Fp = [0.4 SDS Ip Wp ((1+2.5(z/h) / Ru) (CAR/Rpo)(ASCE 7, 13.3-1) =2,386.7 lbs Fp,MAX = 1.6 SDS Ip Wp Fp,MIN = 0.3 SDS Ip Wp =14,320.0 lbs =2685.0 lbs Therefore Fp =2,685 lbs Light Pole Wp =150 lbs Fp = [0.4 SDS Ip Wp ((1+2.5(z/h) / Ru) (CAR/Rpo)(ASCE 7, 13.3-1) =47.7 lbs Fp,MAX = 1.6 SDS Ip Wp Fp,MIN = 0.3 SDS Ip Wp =286.4 lbs =53.7 lbs Therefore Fp =54 lbs 7 1.2 Wind Loads on Equipment (2025 CBC) Basic Wind Speed =95 mph Exposure =C Mean Roof Height (h) =6.3 ft < 60 ft Wind Loads on Other Structures (ASCE 7-10, 29.5 / ASCE 7-16 & 22, 29.4) Supercharger_Cabinet_V4 W =4.6 ft D =3.9 ft H =6.3 ft Eff. Wind Area =28.8 ft2 24.3 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =1.30 qz = 0.00256 Kz Kzt Kd V2 (lb/ft2) Kz = 2.01 (z/zg)2/ where z =15.00 ft zg =900 ft  =9.5 Kz =0.85 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =17.7 psf Threfore, p =19.5 psf Wind Force W =560 lbs 8 Switchboard W =11.2 ft D =4.2 ft H =7.6 ft Eff. Wind Area =84.7 ft2 31.6 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =1.30 qz = 0.00256 Kz Kzt Kd V2 (lb/ft2) Kz = 2.01 (z/zg)2/ where z =15.00 ft zg =900 ft  =9.5 Kz =0.85 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =17.7 psf Threfore, p =19.5 psf Wind Force W =1,650 lbs 9 Light Pole W =0.3 ft D =0.3 ft H =12.0 ft Eff. Wind Area =4.0 ft2 4.0 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =2.07 qz = 0.00256 Kz Kzt Kd V2 (lb/ft2) Kz = 2.01 (z/zg)2/ where z =15.00 ft zg =900 ft  =9.5 Kz =0.85 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =17.7 psf Threfore, p =31.0 psf Wind Force W =124 lbs =10 plf from 3 ft to 15 ft 10 Light Fixture W =5.5 ft D =0.9 ft H =0.4 ft Eff. Wind Area =2.3 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =1.72 qz = 0.00256 Kz Kzt Kd V2 (lb/ft2) Kz = 2.01 (z/zg)2/ where z =18.00 ft zg =900 ft  =9.5 Kz =0.88 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =18.3 psf Threfore, p =26.9 psf Wind Force W =62 lbs at 15 ft 11 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | V4 Cabinet Anchorage Page: Specifier: E-Mail: Date: 1 Yoo Jin Kim yokim@tesla.com 4/21/2026 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 1/2 (3 1/4 ) hnom3 Item number: 2210262 KB-TZ2 1/2x5 1/2 SS304 Specification text: HILTI Æ 1/2 IN KWIK BOLT TZ2 - SS 304 WITH 3.75 IN NOMINAL EMBEDMENT DEPTH PER ICC-ES ESR-4266 , HAMMER DRILL BIT INSTALLATION PER MPII Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 304 Evaluation Service Report: ESR-4266 Issued I Valid: 12/1/2025 | 12/1/2027 Proof: Design Method ACI 318-19 / Mech Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b) Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : lx x ly x t = 3.000 in. x 3.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 10.000 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: > No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, ft.lb] 12 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | V4 Cabinet Anchorage Page: Specifier: E-Mail: Date: 2 Yoo Jin Kim yokim@tesla.com 4/21/2026 1.1 Design results Case Description Forces [lb] / Moments [ft.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 843; Vx = 541; Vy = 162; Mx = 0.000; My = 0.000; Mz = 0.000; yes 43 13 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | V4 Cabinet Anchorage Page: Specifier: E-Mail: Date: 3 Yoo Jin Kim yokim@tesla.com 4/21/2026 2 Proof I Utilization (Governing Cases) Design values [lb]Utilization Loading Proof Load Capacity bN / bV [%]Status Tension Concrete Breakout Failure 843 1,999 43 / -OK Shear Concrete edge failure in direction y+565 1,985 - / 29 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.422 0.284 5/3 37 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 14 www.hilti.com Hilti PROFIS Engineering 3.1.30 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | V4 Cabinet Anchorage Page: Specifier: E-Mail: Date: 4 Yoo Jin Kim yokim@tesla.com 4/21/2026 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 15 Access Point / Cradle Poin W =0.8 ft D =0.6 ft H =0.7 ft Eff. Wind Area =0.5 ft2 0.4 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =2.02 qz = 0.00256 Kz Kzt Kd V2 (lb/ft2) Kz = 2.01 (z/zg)2/ where z =15.00 ft zg =900 ft  =9.5 Kz =0.85 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =17.7 psf Threfore, p =30.4 psf Wind Force W =15 lbs at 15 ft 16 This output has been based on IBC 2024. The EOR has reviewed it and made any necessary revisions in order to conform to the 2025 CBC and its relevant adoptions & amendments. Pole Footing Embedded in Soil LIC# : KW-06013540, Build:20.26.02.06 TESLA (c) ENERCALC, LLC 1982-2026 DESCRIPTION:Light Pole Pier - 12 ft Project File: Santa Ana.ec6 Load Combinations Used : ASCE 7-22 / IBC 2024 Code References Governing Code : IBC 2024 1807.3 General Information Circula 24.0 200.0 1,500.0 No Lateral Restraint at Ground Surface Pole Footing Shape Pole Footing Diameter . . . . . . . . . in llow Passive . . . . . . . . . . . . . . . .pcf Max Passive . . . . . . . . . . . . . . . . .psf Calculate Min. Depth for Allowable Pressures +D+0.60WGoverning Load Combinatio Lateral Load 0.1182 Moment 1.341 k-ft Minimum Required Depth 3.250 ft k NO Ground Surface Restraint Pressures at 1/3 Depth ctual 211.806 psf llowable 212.445 psf Controlling Values ft^2Footing Base Area 3.142 Maximum Soil Pressure 0.04775 ksf k k k 0.150 k k0.0150 Applied Loads k Lateral Concentrated Load (k) D : Dead Load L : Live Lr : Roof Live S : Snow W : Wind E : Earthquake H : Lateral Earth Load distance above 0.0620 15.0 k k k k k k k ft Lateral Distributed Loads (k TOP of Load above ground surface BOTTOM of Load above ground surface 0.010 15.0 3.0 k/ft k/ft k/ft k/ft k/ft k/ft k/ft ft15.50ground surface ft14.50 Vertical Load (k) k Load Combination Results Factor Soil IncreaseForces @ Ground Surface Load Combination Required Loads - (k) Moments - (ft-k) Depth - (ft) Pressure at 1/3 Depth Allow - (psf)Actual - (psf) 0.00.000 0.000D Only 0.13 1.0000.0 211.80.118 1.341+D+0.60W 3.25 1.000212.4 191.30.089 1.006+D+0.450W 2.88 1.000191.7 211.80.118 1.341+0.60D+0.60W 3.25 1.000212.4 0.00.000 0.000+0.60D 0.13 1.0000.0 17 1.3 Anchor Bolt Design Supercharger_Cabinet_V4 2025 CBC Wind=560 lbs SDC= D Hc =6.3 ft. COG =3.2 ft. EQ*Ω=2,166 lbs Ω= 2.5 Dc =2.8 ft.Wc =3.5 ft. DL =2,420 lbs Load combination used for the design: 0.661 DL + 1.0 EQ (0.9-0.2SDS) for EQ load combination 0.900 DL + 1.0 WL 1 V_EQ =2,166 lbs 1 V_EQ x 0.3=650 lbs (orthogonal direction) Wp =0.661 DL =1,600 lbs MOT =V x COG MOT =V x COG =6,836 lb-ft =2,051 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =2,201 lb-ft =2,834 lb-ft M =MOT - MR M =MOT - MR =4,636 lb-ft =-783 lb-ft 1 V_WL =560 lbs 1 V_WL x 0.3=168 lbs (orthogonal direction) Wp =0.9 DL =2,178 lbs MOT =V x COG MOT =V x COG =1,769 lb-ft =531 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =2,995 lb-ft =3,857 lb-ft M =MOT - MR M =MOT - MR =-1,226 lb-ft =-3,326 lb-ft M_Worst =4,636 lb-ft =-783 lb-ft Anchor Bolts for Supercharger_Cabinet_V4 Bolt Number =4 T (Tension on Bolt) = (M / Dc) / 2 bolts T (Tension on Bolt) = (M / Wc) / 2 bolts =843 lbs. =0 lbs. V (Shear on Bolt) = V / 4 bolts V (Shear on Bolt) = V / 4 bolts =541 lbs. =162 lbs. V Wp Hc T Dc 18 Switchboard 2025 CBC Wind=1,650 lbs SDC= D Hc =7.6 ft. COG =3.8 ft. EQ*Ω=6,713 lbs Ω= 2.5 Dc =2.4 ft.Wc =3.0 ft. DL =7,500 lbs Load combination used for the design: 0.661 DL + 1.0 EQ (0.9-0.2SDS) for EQ load combination 0.900 DL + 1.0 WL 1 V_EQ =6,713 lbs 1 V_EQ x 0.3=2,014 lbs (orthogonal direction) Wp =0.661 DL =4,960 lbs MOT =V x COG MOT =V x COG =25,452 lb-ft =7,635 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =5,993 lb-ft =7,440 lb-ft M =MOT - MR M =MOT - MR =19,458 lb-ft =195 lb-ft 1 V_WL =1,650 lbs 1 V_WL x 0.3=495 lbs (orthogonal direction) Wp =0.9 DL =6,750 lbs MOT =V x COG MOT =V x COG =6,255 lb-ft =1,877 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =8,156 lb-ft =10,125 lb-ft M =MOT - MR M =MOT - MR =-1,901 lb-ft =-8,248 lb-ft M_Worst =19,458 lb-ft =195 lb-ft Anchor Bolts for Switchboard Bolt Number =18 T (Tension on Bolt) = (M / Dc) / 9 bolts T (Tension on Bolt) = (M / Wc) / 9 bolts =895 lbs. =7 lbs. V (Shear on Bolt) = V / 18 bolts V (Shear on Bolt) = V / 18 bolts =373 lbs. =112 lbs. V Wp Hc T Dc 19 www.hilti.com Hilti PROFIS Engineering 3.1.26 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Switchboard Anchorage Page: Specifier: E-Mail: Date: 1 Yoo Jin Kim yokim@tesla.com 2/12/2026 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 1/2 (3 1/4 ) hnom3 Item number: 2210262 KB-TZ2 1/2x5 1/2 SS304 Specification text: Hilti Æ 1/2 in Kwik Bolt TZ2 - SS 304 with 3.75 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 304 Evaluation Service Report: ESR-4266 Issued I Valid: 10/1/2024 | 12/1/2025 Proof: Design Method ACI 318-19 / Mech Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b) Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plateR : lx x ly x t = 3.000 in. x 3.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 10.000 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present edge reinforcement: > No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) Shear load: yes (17.10.6.3 (c)) R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, ft.lb] 20 www.hilti.com Hilti PROFIS Engineering 3.1.26 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Switchboard Anchorage Page: Specifier: E-Mail: Date: 2 Yoo Jin Kim yokim@tesla.com 2/12/2026 1.1 Design results Case Description Forces [lb] / Moments [ft.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 902; Vx = 373; Vy = 112; Mx = 0.000; My = 0.000; Mz = 0.000; yes 38 21 www.hilti.com Hilti PROFIS Engineering 3.1.26 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Switchboard Anchorage Page: Specifier: E-Mail: Date: 3 Yoo Jin Kim yokim@tesla.com 2/12/2026 2 Proof I Utilization (Governing Cases) Design values [lb]Utilization Loading Proof Load Capacity bN / bV [%]Status Tension Concrete Breakout Failure 902 2,428 38 / -OK Shear Concrete edge failure in direction y+389 2,666 - / 15 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.372 0.146 5/3 24 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 22 www.hilti.com Hilti PROFIS Engineering 3.1.26 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Switchboard Anchorage Page: Specifier: E-Mail: Date: 4 Yoo Jin Kim yokim@tesla.com 2/12/2026 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 23 2. Equipment Concrete Pad Design (2025 CBC) Supercharger_Cabinet_V Material Properties: fc' =2.5 ksi (= Concrete Compressive Stress) c =150 pcf (= Concrete Unit Weight) Concrete Pad Dimension: B =4.8 ft L =5.6 ft t = 0.83 ft 10"pad s =0.0 ft, Eccentricity A = 27.0 ft2 Wc = 3,373 lbs Stability Check :(in Short Direction) Equipment Weight, We =2,420 lbs 0.7EQ = 606 lbs COG = 4.0 Total Vertical Load, Q = 5,793 lbs 0.6WL = 336 lbs Seismic:MR =0.6Wcx(B/2)+0.6(We-0.14SdsWe)x(B/2-s)MOT =0.7 x V x COG =7.4 kips-ft =2.4 kips-ft FS =MR/ MOT =3.1 > 1.0 (O.K) Wind:MR =0.6Wc x (B/2) + 0.6We x (B/2-s)MOT =0.6 x V x COG =8.4 kips-ft =1.3 kips-ft FS =MR/ MOT =6.3 > 1.0 (O.K) Bearing Pressure Check: qallow =1,500 psf e =MOT / Q =0.4 ft < B/6 qmax =Q/A (1+6e/B)qmin =Q/A (1-6e/B) =326 psf =103 psf qmax =326 psf < 1,500 psf (O.K) Sliding Check : Vmax=606 lbs f =0.35 Vresisting=0.6Q x f =1,217 lbs >606 lbs (O.K) As min. Check :min =0.0018 (for fy = 60 ksi) try #5 @ 16 inch O.C. As,req =0.29 in < As =0.31 in (O.K) L B t 24 (2025 CBC) Switchboard Material Properties: fc' =2.5 ksi (= Concrete Compressive Stress) c =150 pcf (= Concrete Unit Weight) Concrete Pad Dimension: B =5.2 ft L =12.2 ft t = 0.83 ft 10"pad s =0.0 ft, Eccentricity A = 62.9 ft2 Wc = 7,858 lbs Stability Check :(in Short Direction) Equipment Weight, We =7,500 lbs 0.7EQ = 1,880 lbs COG = 4.6 Total Vertical Load, Q = 15,358 lbs 0.6WL = 990 lbs Seismic:MR =0.6Wcx(B/2)+0.6(We-0.14SdsWe)x(B/2-s)MOT =0.7 x V x COG =20.6 kips-ft =8.7 kips-ft FS =MR/ MOT =2.4 > 1.0 (O.K) Wind:MR =0.6Wc x (B/2) + 0.6We x (B/2-s)MOT =0.6 x V x COG =23.8 kips-ft =4.6 kips-ft FS =MR/ MOT =5.2 > 1.0 (O.K) Bearing Pressure Check: qallow =1,500 psf e =MOT / Q =0.6 ft < B/6 qmax =Q/A (1+6e/B)qmin =Q/A (1-6e/B) =405 psf =84 psf qmax =405 psf < 1,500 psf (O.K) Sliding Check : Vmax=1,880 lbs f =0.35 Vresisting=0.6Q x f =3,225 lbs >1,880 lbs (O.K) As min. Check :min =0.0018 (for fy = 60 ksi) try #5 @ 16 inch O.C. As,req =0.29 in < As =0.31 in (O.K) L B t 25 STRUCTURAL DESIGN OF TESLA STEEL SKID FOUNDATIONS PROJECT: PRE-ASSEMBLED SUPERCHARGER FOLDING UNIT - P.S.F.U. - FOLDED POSITION REPORT PREPARED FOR: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 PROJECT DESIGNED BY: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 26 Design Summary Design Criteria Code References International Building Code 2015 / 2018 / 2021 / 2024 California Building Code 2025 ASCE 7-10 / ASCE 7-16 / ASCE 7-22 AISC 360 - 19 Wind Load Design Parameters Risk Category II Basic Wind Speed V =113 mph (3-second gust) Exposure C Seismic Design Parameters Risk Category II Importance Factor, I 1.0 Soil Properties Allowable Bearing Pressure 1,500 psf Allowable Lateral Bearing Pressure 200 psf/ft Structural Steel Strength (fy)50 ksi designed to withstand both wind and seismic loading. Overall strength and stability of the foundation and anchorage checks 27 1. Lateral Loads Calculation for Equipment (IBC2018/2021/2024, CBC2025) 1.1 Earthquake Load Soil Site Class =D Seismic Use Group =II SDS =2.50 g Seismic Design Category =D ρ =1.0 (ASCE 7, 12.3.4.1) Seismic Design Force : 2.5 ap 1.0 (ASCE 7, Table 13.6-1) p 1.0 z/h =0.0 Supercharger_Cabinet_V4 2,240 lbs =896.0 lbs p,MAX DS p p p,MIN DS p p =8,960.0 lbs =1680.0 lbs Therefore 1,680 lbs Supercharger_Post_V4 198 lbs =79.2 lbs =792.0 lbs =148.5 lbs Therefore 149 lbs Skid at V4 Cabinet 1,000 lbs =400.0 lbs =4,000.0 lbs =750.0 lbs Therefore 750 lbs 2,850 lbs =1,140.0 lbs =11,400.0 lbs =2137.5 lbs Therefore 2,138 lbs + foldable) 28 Light Pole W p 100 lbs =40.0 lbs =400.0 lbs =75.0 lbs Therefore 75 lbs Light Fixture 50 lbs =20.0 lbs =200.0 lbs =37.5 lbs Therefore 38 lbs 29 1.2 Wind Loads on Equipment (IBC2018/2021/2024, CBC2025) Basic Wind Speed =113 mph Exposure =C Mean Roof Height (h) =6.3 ft <60 ft Wind Loads on Other Structures (ASCE 7-10, 29.5 / ASCE 7-16 & 22, 29.4) Supercharger_Cabinet_V4 W =4.7 ft D =3.6 ft H =6.3 ft Eff. Wind Area =29.5 ft2 22.6 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =1.31 α 15.00 ft 900 ft α =9.5 0.85 =1.0 0.9 Threfore, 25.0 psf Threfore, 27.9 psf Wind Force W =821 lbs 530 Supercharger_Post_V4 W =2.2 ft D =1.0 ft 6.4 ft Eff. Wind Area =14.3 ft2 6.3 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =1.18 α 15.00 ft 900 ft α =9.5 0.85 1.0 0.95 Threfore, 26.4 psf Threfore, 26.5 psf 378 lbs 631 Skid at V4 Cabinet W =6.2 ft D =4.3 ft H =0.8 ft 5.2 ft2 3.5 ft2 (ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =1.29 α 15.00 ft 900 ft α =9.5 0.85 =1.0 Kd =0.9 Threfore, 25.0 psf Threfore, 27.3 psf 141 lbs 732 Skid at folded wings (fixed + foldable) W =14.8 ft D =4.3 ft H =0.8 ft 12.4 ft2 3.5 ft2 (ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =1.29 α 15.00 ft 900 ft α =9.5 0.85 =1.0 Kd =0.9 Threfore, 25.0 psf Threfore, 27.3 psf 338 lbs 833 1.3 Anchor Bolt Design Supercharger_Cabinet_V4 (IBC2018/2021/2024, CBC2025) Wind=821 lbs SDC=D EQ*Ω=1,680 lbs Ω=1 Ve=1,680 lbs Vw=821 lbs c 6.3 ft.COG =3.58 ft. 3.3 ft.W c =4.17 ft. 896 lbs =2,016 lbs OT e OT w 6,006 lb-ft =2,937 lb-ft R p c R 1,463 lb-ft =3,293 lb-ft M = =4,543 lb-ft =-356 lb-ft V x 0.3= 504 lbs M x 0.3=-65 lbs Anchor Bolts for Supercharger_Cabinet_V4 4 T (Tension on Bolt) =(M / Dc) / 2 bolts T (Tension on Bolt) =(M / Wc) / 2 bolts =695 lbs.=0 lbs. V (Shear on Bolt) =V / 4 bolts V (Shear on Bolt) =V / 4 bolts =420 lbs.=126 lbs. bolt nom. nt nv nt Use (4) 5/8" diam. A307 thru bolts or better. apply Hc 34 Supercharger_Post_V4 (IBC2018/2021/2024, CBC2025) Wind=378 lbs SDC=D EQ*Ω=149 lbs Ω=1 Ve=149 lbs Vw=378 lbs c 6.4 ft.COG =3.61 ft. 0.4 ft.W c =1.67 ft. 79 lbs =178 lbs OT e OT w 536 lb-ft =1,363 lb-ft R p c R p 16 lb-ft =35 lb-ft M = =520 lb-ft =1,328 lb-ft V x 0.3= 113 lbs M x 0.3=260 lbs Anchor Bolts for Supercharger_Post_V4 4 T (Tension on Bolt) =(M / Dc) / 2 bolts T (Tension on Bolt) =(M / Wc) / 2 bolts =1,686 lbs.=78 lbs. V (Shear on Bolt) =V / 4 bolts V (Shear on Bolt) =V / 4 bolts =94 lbs.=28 lbs. bolt nom. nt nv nt Use (4) 5/8" diam. A307 thru bolts or better. apply VHc 1035 Light Pole W =0.33 ft D =0.33 ft 12.0 ft Eff. Wind Area =4.0 ft2 4.0 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7- where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, =1.77 α 15.00 ft 900 ft α =9.5 0.85 1.0 0.9 Threfore, 25.0 psf Threfore, 37.5 psf 150 lbs =13 plf Moment =900 lbs-ft 16 & 22, 29.4-1) Fig. 29.4-1) 36 Light Fixture W =2.7 ft D =0.7 ft H =0.4 ft 1.1 ft2 (ASCE 7-10, 29.5-1 0.85 (ASCE 7-10, Fig. 29.5-1 / =1.73 α 22.00 ft 900 ft α =9.5 0.92 =1.0 Kd =0.9 Threfore, 27.1 psf Threfore, 39.8 psf 45 lbs Moment =539 lbs-ft Tu = 2,641 lbs. Vu = 195 lbs. 9.25 in Use (4) 5/8" diam. A307 thru bolts or better. apply / ASCE 7-16 & 22, 29.4-1) ASCE 7-16 & 22, Fig. 29.4-1) O.K O.K. 37 2. Equipment Concrete Pad Design Supercharger_Cabinet_V4 1 # of units Other Misc. Equipment - Light Pole 2 # of units Supercharger_Post_V4 8 # of units DL=300.0 lbs Skid at V4 Cabinet 1 # of units EL=225.0 lbs Skid at folded wings (fixed + foldable)2 # of units WL=389.9 lbs Height=12 ft Passive =200 psf/ft Material Properties: γ =0 ballast unit weight, pcf. Enter "0" if no ballast is used γ =0 concrete unit weight, pcf. Enter "0" if no concrete used Ballast Dimensions: ballast 4.25 ft, ballasting width ballast 35.85 ft, ballasting length 74 % of interior used for ballasting 0 lbs B =0 ft, concrete pad width, Enter "0" if no pad L =0 ft, concrete pad length, Enter "0" if no pad 0.83 ft, skid thickness concrete 0.00 ft, concrete pad thickness, Enter "0" if no pad s =0.0 ft - skid C.L. to equip. C.L. s1 =0.0 ft - pad C.L. to skid. C.L., Enter "0" if no pad A =0.0 0 lbs 0.500 ft (in Short Direction) Stability Check : Equipment Weight =10,824 lbs Total Vertical Load, Q =10,824 lbs 2.74 lbs -------->12.4 kips-ft 20.7 kips-ft 0.00 kips-ft 0.27 kips-ft R (Total) seismic 21.0 kips-ft 1.91 >1.0 15.4 kips-ft R (ftg.) 0.67D 0.0 kips-ft R (passive.)0.67D 0.20 kips-ft 15.6 kips-ft 1.26 >1.0 Sliding Check :f = 0.30 - friction coeff. 2.9 kips R (passive) 0.9D 0.8 kips 3.7 kips 1.02 >1.0 R (friction) 0.67D 2.2 kips R (passive) 0.67D 0.6 kips 2.8 kips 1.01 >1.0 0.67 x Weq x (B/2-s)= Combined Pad - Yes (IBC2018/2021/2024, CBC2025) 0.9 x Weq x (B/2-s)= 0.9 x Wc x B/2 = Skid. depth below soil = FS = MR/ MOT (0.7EQ) = (O.K) (O.K) (O.K) FS = MR/ MOT (0.6W) = FS = V / V = FS = VR/ V0.6W = (O.K) L 38 Bearing Pressure Check: qallow =1500 psf 0.00 kips-ft 12.4 kips-ft B=4.3 ft. L=35.9 ft. OT 205 psf =0 psf 205 psf <1,500 psf (O.K) 0.6V (wind) x COG= 39 STRUCTURAL DESIGN OF TESLA PRECAST FOUNDATIONS PROJECT: Supercharger Post - V4 on PLP Foundation REPORT PREPARED FOR: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 PROJECT DESIGNED BY: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 40 Design Summary Design Criteria Code References International Building Code 2015 / 2018 / 2021 / 2024 California Building Code 2022 / 2025 ASCE 7-10 / ASCE 7-16 / ASCE 7-22 ACI 318-14 / ACI 318-19 Wind Load Design Parameters Risk Category II Basic Wind Speed V = 170 mph (3-second gust) Exposure C Seismic Design Parameters Risk Category II Importance Factor, I 1.0 SDS 3.000 Soil Properties Allowable Bearing Pressure 1,500 psf Allowable Lateral Bearing Pressure 300 psf/ft (compacted gravel) Backfill Weight (Compacted)150 pcf This calculation report is for the design of precast foundations by PLP for Supercharger Post - V4. The foundations were designed to withstand both wind and seismic loading. Overall strength and stability of the foundation and anchorage checks have been completed. 41 1. Lateral Loads Calculation for Equipment (2021 / 2024 IBC) 1.1 Earthquake Load Soil Site Class =D Seismic Use Group =II From Spectrum Data: SDS =3.000 g Seismic Design Category =E  =1.0 (ASCE 7, 12.3.4.1) Seismic Design Force :(for Nonstructural Components) R =2.5 ap =1.0 (ASCE 7, Table 13.6-1) Ip =1.0 z/h =0.0 Supercharger_Post_V4 Wp =198 lbs Fp = [0.4 ap SDS Wp / (Rp/Ip)] x (1+2(z/h))(ASCE 7, 13.3-1) =95.0 lbs Fp,MAX = 1.6 SDS Ip Wp Fp,MIN = 0.3 SDS Ip Wp =950.4 lbs =178.2 lbs Therefore Fp =178 lbs 42 1.2 Wind Loads on Equipment (2021 / 2024 IBC) Basic Wind Speed =170 mph Exposure =C Mean Roof Height (h) =6.4 ft < 60 ft Wind Loads on Other Structures (ASCE 7-10, 29.5 / ASCE 7-16 & 22, 29.4) Supercharger_Post_V4 W =2.2 ft D =1.0 ft H =6.4 ft Eff. Wind Area =14.3 ft2 6.3 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =1.39 qz = 0.00256 Kz Kzt Kd V2 I (lb/ft2) Kz = 2.01 (z/zg)2/ where z =15.00 ft zg =900 ft  =9.5 Kz =0.85 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =56.5 psf Threfore, p =66.8 psf Wind Force W =953 lbs > EQ =178 lbs 43 1.3 Anchor Bolt Design Supercharger_Post_V4 2021 / 2024 IBC Wind=953 SDC= E EQ*Ω*Ip AB=178 Ω= 1 Ip AB= 1.00 Load combination used for the design: 0.9 DL + 1.0 W (0.9-0.2SDS) if EQ Governs 1 V =953 lbs 1 V x 0.3=286 lbs (orthogonal direction) Hc =6.4 ft. COG =3.2 ft. Dc =0.4 ft.Wc =1.7 ft. Wp =0.9 DL =178 lbs MOT =V x COG MOT =V x COG =3,041 lb-ft =912 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =35 lb-ft =149 lb-ft M =MOT - MR M =MOT - MR =3,006 lb-ft =763 lb-ft Anchor Bolts for Supercharger_Post_V4 Bolt Number =4 Dia. of Bolt =5/8 inch / A307 or better T (Tension on Bolt) = (M / Dc) / 2 bolts T (Tension on Bolt) = (M / Wc) / 2 bolts =3,818 lbs. =228 lbs. V (Shear on Bolt) = V / 4 bolts V (Shear on Bolt) = V / 4 bolts =238 lbs. =71 lbs. Max T =4,046 lbs. Max V =249 lbs. Fnv =24.0 ksi.Fnt =45.0 ksi.=0.75 A =  r2 =0.307 in2 fv =V / A =0.81 ksi. < Fv=18.0 ksi. (O.K.) ft =T / A =13.19 ksi. < Ft =33.8 ksi. (O.K.) V Wp Hc T Dc 44 2. Foundation Check (2021 / 2024 IBC) Supercharger_Post_V4 Material Properties: Wf = 244.0 lbs (from manufacturer's drawing) g =150 pcf for backfill soil plat =300 psf/ft Foundation Dimension: (top 3" ignored) P 634.4 psf Section Modulus, S = 12,035 in3 = 6.965 ft Passive Pressure: P = (0+634.375 psf)/2 x 38.61 in x 22.38 in = 1903.3 lbs P_lat = 1903.3 lbs Resisting Moment from Lateral Pressure: M = 1903.3 lbs x 1.865 ft /3 1183.2 lb-ft M_lat = 1183.2 lb-ft 45 Stability Check : Equipment Weight, We = 198 lbs Eccentricity, s = 0.78 ft Precast Foundation Weight = 244 lbs Back Fill Inside = 2,285 lbs Wc = 2,529 lbs (60% filled) Total Vertical Load, Q = 2,727 lbs MR =0.6(Wc x (B/2) + We x (B/2-s) + M_lat) B =3.22 ft =3.25 kips-ft Lateral Loads = 572 lbs (service level) COG = 5.3 ft MOT =3.19 kips-ft including moment due to eccentricity FS =MR/ MOT =1.02 > 1.0 (O.K) Bearing Pressure Check: qallow =1,500 psf A =12.988 ft2 Section Modulus, S = 6.965 ft3 qmax = Q/A +MOT/S =668 psf < 1,500 psf (O.K) Sliding Check : Vmax=572 lbs f =0.35 Vresisting=0.6(Q x f +P_lat) =1,715 lbs >572 lbs (O.K) 46 A B C D E F 1 2 3 4 5 A B C D 1 2 3 4 FILENAME: LEVEL3-ASSEMBLY 5 C V E CLEVELAND, OHIO 44143 +1 440 461 5200 PLP.COM 38.61 37.32 48.44 47.14 25.38 UNITS DO NOT SCALE THIRD ANGLE PROJECTION TOLERANCES UNLESS NOTED .xx .01 .xxx .005 x/xx 1/32 ANGLES 2 CONFIDENTIAL THIS DRAWING IS THE EXCLUSIVE PROPERTY OF (PREFORMED LINE PRODUCTS COMPANY) AND IS TO BE USED ONLY WITH THE PRIOR EXPRESSED PERMISSION OF PLP PRODUCTION DRAWING TITLE DRWN: DATE:PART NUMBER DRAWING NUMBER 5600039 560-0039APVD:DATE: APVD:DATE: SCALE SHEET No ORIGIN REV 0.09 : 1.00 1 OF 1 C QUALITY PLAN QTY.LABEL 0 CRITICALDIMENSION 0 VISUALINSPECTION REV REV DATE DRWN APVD APVD CHANGENUMBER DESCRIPTION LIST OF GAGES AND IDs A - DEDICATED/SPECIAL GAGING METHOD PER NOTESB - PD: THREADED PLUG GAGE(S) MIN : GO/NO-GO PIN GAGESD - PD: THREADED RING GAGE(S) MAJ : MICROMETERE - PITCH MICROMETERF - CMM / OPTICAL CMMG - OPTICAL COMPARATORH - MICROMETERJ - BEST FIT PIN GAGES AND CALIPERK - GO / NO-GO PIN GAGESL - HEIGHT GAGE / SURFACE PLATEM - CALIPERN - TAPE MEASURE IN CASE OF DISPUTE BETWEEN THE SUPPLIER AND PURCHASER, THESE GAGES ARE TO BE USED AS THE REFEREE METHOD. GAGES ARE LISTED IN ORDER OFGAGING RANKING, WITH "A" BEING THEHIGHEST RANKED GAGE. ANY APPLICABLE GAGE OF HIGHERRANKING MAY BE USED IN PLACE OFTHE SPECIFIED GAGE, IF SO DESIRED. SCALE 0.070 47 STRUCTURAL DESIGN OF TESLA CAST-IN- PLACE FOUNDATIONS PROJECT: SUPERCHARGER CHARGE POS V3 & V4 DUAL - TWO POSTS REPORT PREPARED FOR: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 PROJECT DESIGNED BY: Tesla, Inc. 3500 Deer Creek Road Palo Alto, CA 94304 510-647-6816 48 Design Summary Design Criteria Code References International Building Code 2015 / 2018 / 2021 / 2024 California Building Code 2025 ASCE 7-10 / ASCE 7-16 / ASCE 7-22 ACI 318-14 / ACI 318-19 Wind Load Design Parameters Risk Category II Basic Wind Speed V = 108 mph (3-second gust) Exposure C Seismic Design Parameters Risk Category II Importance Factor, I 1.0 SDS 3.000 Soil Properties Allowable Bearing Pressure 1,500 psf Allowable Lateral Bearing Pressure 100 psf/ft Reinforced Concrete Strength (fc')2,500 psi This calculation report is for the design of CIP foundations for the Tesla Supercharger Charge Post - V3 and V4 Dual with Two Posts. The foundations were designed to withstand both wind and seismic loading. Overall strength and stability of the foundation and anchorage checks have been completed. 49 1. Lateral Loads Calculation for Equipment (2024 IBC) 1.1 Earthquake Load Soil Site Class =D Seismic Use Group =II From Spectrum Data: SDS =3.000 g Seismic Design Category =E  =1.0 (ASCE 7, 12.3.4.1) Seismic Design Force :(for Nonstructural Components) R =2.5 ap =1.0 (ASCE 7, Table 13.6-1) Ip =1.0 z/h =0.0 Supercharger_Post_V4 Wp =198 lbs Fp = [0.4 ap SDS Wp / (Rp/Ip)] x (1+2(z/h))(ASCE 7, 13.3-1) =95.0 lbs Fp,MAX = 1.6 SDS Ip Wp Fp,MIN = 0.3 SDS Ip Wp =950.4 lbs =178.2 lbs Therefore Fp =178 lbs Supercharger_Post_V3 Wp =140 lbs Fp = [0.4 ap SDS Wp / (Rp/Ip)] x (1+2(z/h))(ASCE 7, 13.3-1) =67.2 lbs Fp,MAX = 1.6 SDS Ip Wp Fp,MIN = 0.3 SDS Ip Wp =672.0 lbs =126.0 lbs Therefore Fp =126 lbs EV Sign Wp =20 lbs Fp = [0.4 ap SDS Wp / (Rp/Ip)] x (1+2(z/h))(ASCE 7, 13.3-1) =9.6 lbs Fp,MAX = 1.6 SDS Ip Wp Fp,MIN = 0.3 SDS Ip Wp =96.0 lbs =18.0 lbs Therefore Fp =18 lbs 50 1.2 Wind Loads on Equipment (2024 IBC) Basic Wind Speed =108 mph Exposure =C Mean Roof Height (h) =6.4 ft < 60 ft Wind Loads on Other Structures (ASCE 7-10, 29.5 / ASCE 7-16 & 22, 29.4) Supercharger_Post_V4 W =2.2 ft D =1.0 ft H =6.4 ft Eff. Wind Area =14.3 ft2 6.3 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =1.39 qz = 0.00256 Kz Kzt Kd V2 I (lb/ft2) Kz = 2.01 (z/zg)2/ where z =15.00 ft zg =900 ft  =9.5 Kz =0.85 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =22.8 psf Threfore, p =27.0 psf Wind Force W =385 lbs > EQ =178 lbs 51 Supercharger_Post_V3 W =2.7 ft D =0.8 ft Empty Area =5.6 ft2 H =5.5 ft Eff. Wind Area =9.1 ft2 4.5 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =1.40 qz = 0.00256 Kz Kzt Kd V2 I (lb/ft2) Kz = 2.01 (z/zg)2/ where z =15.00 ft zg =900 ft  =9.5 Kz =0.85 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =22.8 psf Threfore, p =27.1 psf Wind Force W =246 lbs > EQ =126 lbs 52 EV Sign W =1.0 ft D =0.02 ft H =1.5 ft Eff. Wind Area =1.5 ft2 0.03 ft2 p =qzGCf (lb/ft2)(ASCE 7-10, 29.5-1 / ASCE 7-16 & 22, 29.4-1) where, G =0.85 where, Cf =force coefficient (ASCE 7-10, Fig. 29.5-1 / ASCE 7-16 & 22, Fig. 29.4-1) =2.00 qz = 0.00256 Kz Kzt Kd V2 I (lb/ft2) Kz = 2.01 (z/zg)2/ where z =15.00 ft zg =900 ft  =9.5 Kz =0.85 Kzt = (1+K1K2K3)2 =1.0 Kd =0.9 Threfore, qz =22.8 psf Threfore, p =38.8 psf Wind Force W =58 lbs at 5.5 ft height 53 1.3 Anchor Bolt Design Supercharger_Post_V4 2024 IBC Wind=385 SDC= E EQ*Ω*Ip AB=446 Ω= 2.5 Ip AB= 1.00 Load combination used for the design: 0.3 DL + 1.0 EQ (0.9-0.2SDS) if EQ Governs 1 V =446 lbs 1 V x 0.3=134 lbs (orthogonal direction) Hc =6.4 ft. COG =2.8 ft. Dc =0.4 ft.Wc =1.7 ft. Wp =0.3 DL =59 lbs MOT =V x COG MOT =V x COG =1,264 lb-ft =379 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =12 lb-ft =50 lb-ft M =MOT - MR M =MOT - MR =1,253 lb-ft =330 lb-ft Anchor Bolts for Supercharger_Post_V4 Bolt Number =4 T (Tension on Bolt) = (M / Dc) / 2 bolts T (Tension on Bolt) = (M / Wc) / 2 bolts =1,591 lbs. =98 lbs. V (Shear on Bolt) = V / 4 bolts V (Shear on Bolt) = V / 4 bolts =111 lbs. =33 lbs. V Wp Hc T Dc 54 Supercharger_Post_V3 2024 IBC Wind=246 SDC= E EQ*Ω*Ip AB=315 Ω= 2.5 Ip AB= 1.00 Load combination used for the design: 0.3 DL + 1.0 EQ (0.9-0.2SDS) if EQ Governs 1 V =315 lbs 1 V x 0.3=95 lbs (orthogonal direction) Hc =5.5 ft. COG =2.8 ft. Dc =0.4 ft.Wc =1.7 ft. Wp =0.3 DL =42 lbs MOT =V x COG MOT =V x COG =872 lb-ft =261 lb-ft MR = Wp x 1/2 Dc MR = Wp x 1/2 Wc =8 lb-ft =35 lb-ft M =MOT - MR M =MOT - MR =863 lb-ft =226 lb-ft Anchor Bolts for Supercharger_Post_V3 Bolt Number =4 T (Tension on Bolt) = (M / Dc) / 2 bolts T (Tension on Bolt) = (M / Wc) / 2 bolts =1,096 lbs. =68 lbs. V (Shear on Bolt) = V / 4 bolts V (Shear on Bolt) = V / 4 bolts =79 lbs. =24 lbs. V Wp Hc T Dc 55 www.hilti.com Hilti PROFIS Engineering 3.0.80 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Charging Post Anchorage - CIP-One Page: Specifier: E-Mail: Date: 1 Yoo Jin Kim yokim@tesla.com 9/26/2022 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - SS 304 1/2 (3 1/4 ) hnom3 Item number: 2210261 KB-TZ2 1/2x4 1/2 SS304 Effective embedment depth: hef,act = 3.250 in., hnom = 3.750 in. Material: AISI 304 Evaluation Service Report: ESR-4266 Issued I Valid: 12/17/2021 | 12/1/2023 Proof: Design Method ACI 318-14 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. Anchor plateR : lx x ly x t = 7.000 in. x 23.000 in. x 0.250 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 18.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, ft.lb] 56 www.hilti.com Hilti PROFIS Engineering 3.0.80 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Charging Post Anchorage - CIP-One Page: Specifier: E-Mail: Date: 2 Yoo Jin Kim yokim@tesla.com 9/26/2022 1.1 Design results Case Description Forces [lb] / Moments [ft.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 0; Vx = 601; Vy = -180; Mx = 399.000; My = 1,679.000; Mz = 0.000; no 60 57 www.hilti.com Hilti PROFIS Engineering 3.0.80 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Charging Post Anchorage - CIP-One Page: Specifier: E-Mail: Date: 3 Yoo Jin Kim yokim@tesla.com 9/26/2022 2 Proof I Utilization (Governing Cases) Design values [lb]Utilization Loading Proof Load Capacity bN / bV [%]Status Tension Concrete Breakout Failure 3,811 6,352 60 / -OK Shear Concrete edge failure in direction y-627 3,095 - / 21 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.600 0.203 5/3 50 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 58 www.hilti.com Hilti PROFIS Engineering 3.0.80 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Charging Post Anchorage - CIP-One Page: Specifier: E-Mail: Date: 4 Yoo Jin Kim yokim@tesla.com 9/26/2022 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 59 www.hilti.com Hilti PROFIS Engineering 3.0.80 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Charging Post Anchorage - CIP-One Page: Specifier: E-Mail: Date: 1 Yoo Jin Kim yokim@tesla.com 9/26/2022 Specifier's comments: 1 Input data Anchor type and diameter: HIT-HY 200 V3 + HAS-R 304/316 SS 1/2 Item number: 2045003 HAS-R 316 SS 1/2"x6 1/2" (element) / 2334276 HIT-HY 200-R V3 (adhesive) Effective embedment depth: hef,act = 4.000 in. (hef,limit = - in.) Material: ASTM F 593 Evaluation Service Report: ESR-4868 Issued I Valid: 11/1/2021 | 11/1/2022 Proof: Design Method ACI 318-14 / Chem Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. Anchor plateR : lx x ly x t = 7.000 in. x 23.000 in. x 0.250 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 18.000 in., Temp. short/long: 32/32 °F Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [lb, ft.lb] 60 www.hilti.com Hilti PROFIS Engineering 3.0.80 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Charging Post Anchorage - CIP-One Page: Specifier: E-Mail: Date: 2 Yoo Jin Kim yokim@tesla.com 9/26/2022 1.1 Design results Case Description Forces [lb] / Moments [ft.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 0; Vx = 601; Vy = -180; Mx = 399.000; My = 1,679.000; Mz = 0.000; Nsus = 0; Mx,sus = 0.000; My,sus = 0.000; no 54 61 www.hilti.com Hilti PROFIS Engineering 3.0.80 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Charging Post Anchorage - CIP-One Page: Specifier: E-Mail: Date: 3 Yoo Jin Kim yokim@tesla.com 9/26/2022 2 Proof I Utilization (Governing Cases) Design values [lb]Utilization Loading Proof Load Capacity bN / bV [%]Status Tension Bond Strength 3,767 7,041 54 / -OK Shear Concrete edge failure in direction y-627 3,226 - / 20 OK Loading bN bV z Utilization bN,V [%]Status Combined tension and shear loads 0.535 0.194 5/3 42 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 62 www.hilti.com Hilti PROFIS Engineering 3.0.80 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Company: Address: Phone I Fax: Design: Fastening point: Tesla 1216 Stealth St, Livermore, CA 94551 | Charging Post Anchorage - CIP-One Page: Specifier: E-Mail: Date: 4 Yoo Jin Kim yokim@tesla.com 9/26/2022 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 63 2. Equipment Concrete Pad Design (2024 IBC) Foundation for Two Charging Posts Material Properties: fc' =2.5 ksi (= Concrete Compressive Stress) c =150 pcf (= Concrete Unit Weight) Concrete Pad Dimension: B =2.0 ft L =9.0 ft t = 1.50 ft 18"pad s =0.0 ft, Eccentricity A = 18.0 ft2 Wc = 4,050 lbs Stability Check :(in Short Direction) Equipment Weight, We =396 lbs 0.7EQ = 415 lbs COG = 4.3 Total Vertical Load, Q = 4,446 lbs 0.6WL = 462 lbs MR =0.6Wc x (B/2) + 0.6We x (B/2-s)MOT =0.6 x V x COG =2.7 kips-ft =2.6 kips-ft FS =MR/ MOT =1.01 > 1.0 (O.K) Bearing Pressure Check: qallow =1,500 psf e =MOT / Q =0.6 ft > B/6 qmax =2Q/3L(B/2-e)qmin =Q/A (1-6e/B) =812 psf =0 psf qmax =812 psf < 1,500 psf (O.K) Sliding Check : Vmax=462 lbs f =0.35 Vresisting=0.6Q x f =934 lbs >462 lbs (O.K) As min. Check :min =0.0018 (for fy = 60 ksi) try #5 @ 16 inch O.C. T&B As,req =0.52 in < As =0.62 in (O.K) L B t 64