Loading...
HomeMy WebLinkAbout10151636.pdf& AND L ANGLE rOz AT 0 DIAMETER OR ROUND # POUND OR NUMBER (E) EXISTING (N) NEW ABV ABOVE ACOUS. ACOUSTICAL A.B. ANCHOR BOLT ADD'L ADDITIONAL ADJ ADJACENT ALUM, ALUMINUM ANG ANGLE APPROX APPROXIMATE BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BEAM B.N. BOUNDARY NAILING B.O. BOTTOM OF B.O.F. BOTTOM OF FOOTING SOT BOTTOM BRG BEARING BSMT BASEMENT BTWN BETWEEN CAB. CABINET GEM CEMENT CER. CERAMIC C.I. CAST IRON C.J. CONSTRUCTION JOINT CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN COLL COLLECTOR CONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS C.T. CERAMIC TILE CTR CENTER CTSK COUNTERSINK d PENNY (NAIL SIZE) D2L NELSON WELDED REBAR DECOR. DECORATIVE DBL DOUBLE DEMO DEMOLITION DET DETAIL D.F. DOUGLAS FIR DIAL DIAGONAL DIA DIAMETER DIM DIMENSION DK, DKG DECK, DECKING DN DOWN DS DOWNSPOUT DWG DRAWING EA EACH EL ELEVATION ELEC ELECTRICAL ELEVR ELEVATOR EMBED EMBEDMENT E.N. EDGE NAIL E.O. EDGE OF E.P.S. EXPANDED POLYSTYRENE EQ EQUAL EQ SP EQUAL SPACES E.S. EACH SIDE EXH EXHAUST EXIST. EXISTING EXP EXPANSION EXT EXTERIOR F.A.U. FORCED AIR UNIT F.D. FLOOR DRAIN F.H.C. FIRE HOSE CABINET FDN FOUNDATION F.F. FINISHED FLOOR FIN FINISH FLR FLOOR FLASH. FLASHING FLOUR. FLOURESCENT F.O.C- FACE OF CONCRETE F.O.F. FACE OF FINISH F.O.M. FACE OF MASONRY F.O.S. FACE OF STUD F.P. FIREPROOFING FRMG FRAMING F.S. FLOOR SINK FT FOOT OR FEET FTG FOOTING ga GAUGE GALV GALVANIZED GC GENERAL CONTRACTOR GL. GLASS GLB GLUE -LAM BEAM GR GRADE GYP GYPSUM H.B. HOSE BIBB H.C. HOLLOW CORE HD HOLDOWN HDR HEADER HDWD HARDWOOD HGR HANGER HGT. HEIGHT H.M. HOLLOW METAL HORIZ,(H) HORIZONTAL HT HEIGHT I.D. INSIDE DIAMETER I.F. INSIDE FACE INCAND. INCANDESCENT INSUL INSULATION INT INTERIOR JAN. JANITOR JST JOIST JT JOINT LAM. LAMINATE LAV. LAVATORY LB POUND LOC. LOCATION LTWT LIGHT WEIGHT LVL LEVEL MAX MAXIMUM MECH MECHANICAL M.E.P. MECHANICAL, ELECTRICAL PLUMBING DOCUMENTS MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS M.O. MASONRY OPENING MTD. MOUNTED MTL METAL MUL. MULLION N NORTH NIC NOT IN CONTRACT NO, NUMBER NOM NOMINAL N.S. NEAR SIDE NTS NOT TO SCALE O.A. OVERALL OBS. OBSCURE OC ON CENTER O.D. OUTSIDE DIAMETER O.F. OUTSIDE FACE O.F.C.I. OWNER FURNISHED / CONTRACTOR INSTALLED OFF. OFFICE OPNG OPENING OPP OPPOSITE PCF POUNDS PER CUBIC FOOT PC, PCS PIECE, PIECES PL. PLATE PLAS. PLASTER PLWD PLYWOOD PR. PAIR PRCST. PRECAST P.T.D.F. PRESSURE -TREATED DOUGLAS FIR PTN. PARTITION Q.T. QUARRY TILE R. RISER RAD RADIUS REF REFERENCE REINF REINFORCING REQ'D REQUIRED RET RETAINING REV REVISE, REVISION RM. ROOM R.O. ROUGH OPENING RWD. REDWOOD R.W.L. RIN WATER LEADER S.C. SOLID CORE S.C.D. SEE CIVIL DRAWINGS SCHED SCHEDULE SECT SECTION S.E.D. SEE ELECTRICAL DRAWINGS SHT SHEET SHTG SHEATHING SIM SIMILAR S.M.D. SEE MECHANICAL DRAWINGS SOG SLAB ON GRADE SPECS SPECIFICATIONS SQ SQUARE SS STAINLESS STEEL S.S.D. SEE STRUCTURAL DRAWINGS STAG STAGGER, STAGGERED STD STANDARD STL STEEL STOR. STORAGE STRUC STRUCTURAL SUSP SUSPENDED SYMM SYMMETRICAL M TREAD T&B TOP AND BOTTOM T&G TONGUE AND GROOVE T.C. TOP OF CURB THK THICK TEL, TELEPHONE THRD THREADED THRU THROUGH TA. TOP OF T.O.C. TOP OF CHIMNEY T.O.F. TOP OF FOOTING (GRADE BEAM) T.O.FR. TOP OF FRMING T.O.L. TOP OF LEDGER T.O.M. TOP OF MASONRY T.O.P. TOP OF PARAPET T.O.PL TOP OF PLATE T.O.S. TOP OF STEEL TS TUBE STEEL TYP TYPICAL LION UNLESS OTHERWISE NOTED URM UNREINFORCED MASONRY VERT,(V) VERTICAL VEST VESTIBULE V.G.D.F, VERTICAL GRAIN DOUGLAS FIR VIF VERIFY IN FIELD W/ WITH W.C. WATER CLOSET WD WOOD WDW. WINDOW W/O WITHOUT W/P WATERPROOFING W.H. WATER HEATER WT WAINSCOT WSCT. WEIGHT CODES: 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 CALIFORNIA BUILDING, PLUMBING, MECHANICAL, AND ELECTRICAL CODES, AND LOCAL ORDINANCES. GENERAL: 1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OR REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. 2. ALL MATERIALS AND FIXTURES ARE TO HAVE APPROVAL FROM AN APPROVED TESTING AGENCY. FOUNDATIONS: ULTIMATE1. CONCRETE TO BE 00 P.S.I. AFTER 28ii 2. PROVIDE 5/6'DIAMETER FOUNDATION BOLTS IMBEDDED T'IN CONCRETE AND SPACED fV-0' ON CENTER (MAXIMUM) AND WITHIN 12" OF A CORNER, W/ 2w"X3/16" WASHERS. 3. y CORROSION RESISTED ! SCREED A FOUNDATION i 1• PLATE ALLOW TRAPPED TO DRAIN TO THE EXTERIOR OF THE BUILDING. MINIMUM 4" HEIGHT ABOVE GRADEAND ABOVE CONC. 4. DRAINAGE PIPING IN THE GROUND SHALL BE LAIDON A FIRM BED FOR IT'S ENTIRE LENGTH AND BACKFILLED IN THIN LAYERS TO 12"ABOVE TOP OF PIPE WITH CLEAN EARTH, FREE FROM ! AND BOULDERS. LUMBER AND -I• T 1. USE DOUGLAS - CONSTRUCTION GRADEFOR 6Xd AND LARGER, D.F. -yi FOR ALL dti 2. ALL LUMBER IN CONTACT CONCRETE OR MASONRY SHALL PRESSURE TREATED OR WOOD RESISTANT TO DECAY. RAFTERS3. RAFTER TIES 4'-O"O.C. ARE REQUIRED IMMEDIATELY ABOVE CEILING JOISTSWHEN it NOT PARALLEL CEILING JOISTS. + PLYWOOD EDGES AT : ••R SHALL HAVE• i GROOVE OR SOLID BLOCKING AT EDGES. CONTAINING5. WALLS OR , r.y WASTEAND VENT PIPINGt r TO ALLOW r AND BORING. BRACING OF t CONFORM :2001. 7. PLYWOOD ROOF PANELS SHALLBE BONDED WITH INTERMEDIATEOR EXTERIOR AND WHERE EXPOSED TO WEATHER, SHALL BE EXTERIOR GRADE. 8. NO STRUCTURAL MEMBER SHALL BE SERIOUSLY OR WEAKENED OR IMPAIRED BY CUTTING OR NOTCHING. NOTCHING9. CUTTING, OR BORING FRAMING MEMBERS SHALL BE IN ACCORDANCE PROPERTY Id ARCHIT STRT ACCErlltf) FOR CONSTRUCTION $,t31AAAT6 ARIE, REQUIRED FOR e lob ;&1i , i4�., s 5 61 ...g $ $g pip F r y.ewS yy�u`yny y: E6a�gM.3kp@.Q�$:�s the alteralfio wvritten amity of Santa Ana, The acceptance of tisolvin and spe, {1.'atkns SMALL NOT be risho, to peraflik nv ba an aippwval of the violation of any v/ / v Accepted B o_. t Date Issued K E. GRASS N PL.'N!)fA71SION 0 / 0 1 zo �- 0 w v z N P i { w YARD (2816 SQ.FT).. k -A tRN 4'-0" . _. ROOF MATERIAL TO BE: ASPHALT 25' EXISTING 6'-0" BLOCK WALL EXISTING 6-0" BL 4161 1264 PROPOSED E r3h, iT ; YP ;---. ELECT PLBG t[{ 1`CH GRADING N- C", € - ,'WA Pd'f+1fAC's EXISTING tV co cv 3 12 tr} 3: 12 I cv Jim E. GRASS E. CONCRETE DRIVE STRIPS PROPERTY EXISTING w z w Y z X u u o � CD z w w BUILDING DEPARTMENT NOTES SCOPE OF WORK: BUILD 499 SQ.FT. 1ST FLOOR ADDITION AT REAR OF EXISTING RESIDENCE. CONDITIONS OF APPROVAL: CODES USED: 2001 C.B.C., C.P.C., C.M.C., C.E.C., AS AMENDED BY STATE OF CALIFORNIA AND LOCAL JURISDICTION ARE APPLICABLE TO THIS PROJECT. OCCUPANCY: R-3 U-1 CONSTRUCTION TYPE: V - N (R-3 & U-1) LOCATION ON PROPERTY: WALL <5' ONE HOUR CONST. NO OPENINGS SHAFTS: ONE HOUR BUILDING AREA: ALLOWABLE AREA: R-3 1227 SF R - UNLIMITED U-1 0 SF U - 1000 SF OCCUPANT LOAD: N/A EXITS REQUIRED: IRED: N/A * l�r1 ! r r r rr 01W, Cif z r) w `"' 9 A-1.1 SITE PLAN ROOF PLAN A-2.0 EXISTING FLOOR PLAN & DEMO PLAN A-2.1 FIRST FLOOR PLAN A-3.1 ELEVATIONS A-4.1 SECTIONS D01 DETAILS S-1.0 STRUCTURAL NOTES S-1.1 FOUNDATION PLAN S-1.2 FRAMING PLAN SD1 STRUCTURAL DETAILS SD2 STRUCTURAL DETAILS M01 T-24 CALCS & FORMS COMPOSITION SHINGLES, CLASS ADDITION RESIDENCE PORCH "A" RATED PER U.B.C. SECTION 302 (d) AND CITY OF SANTA ANA {499 SQ.FT.) {728 SQ.FT.) {8fl SQ.FT.) V �# REQUIREMENTS (25YEAR COMP). NORTH SITE PLAN SCALE: 1 /8" = 1 "-0" WITH CBC 2001. WALLS/FLOORS CONTAINING DRAIN, WASTE AND VENT PIPES, GAS AND/OR ELECTRICAL PIPING CONDUIT SHALL COMPLY WITH CBC 2001. 10. TWO (2) LAYERS OF GRADE "D" PAPER 9FELT) OVER PLYWOOD SHEAR WALLS. BUILDING: 1. ALL DOORS AND SWINGING WINDOWS SHALL BE WEATHER STRIPPED. 2. ALL METAL WINDOWS AND SLIDING GLASS DOORS SHALL BE IN COMPLIANCE WITH ANSI STANDARDS A1341 OR A1342. 3. ALL GLAZING INSTALLATION SHALL COMPLY WITH TITLE 24 OF ENERGY CONSERVATION REQUIREMENTS. 4. EXIT DOORS & ESCAPE WINDOWS MUST BE OPERABLE FROM INSIDE WITHOUT SPECIAL KNOWLEDGE OR USE OF TOOLS. 5. ROOFING MATERIALS TO BE CLASS "C" MINIMUM, ROOF PITCH IS 1/4" PER FOOT. LIGHT AND VENTILATION: 1. ROOMS USED FOR LIVING, SLEEPNG, EATING OR COOKING SHALL BE PROVIDED WITH NATURAL LIGHT EQUAL TO ONE TENTH OF THE FLOOR AREA WITH A MIN. OF 10 SQ.FT. 2. ROOMS USED FOR LIVING, SLEEPNG, EATING OR COOKING SHALL BE PROVIDED WITH NATURAL VENTILATION EQUAL TO ONE TWENTIETH OF THE FLOOR AREA WITH A MIN. OF 15 SQ. FT. 3. BATHROOMS, LAUNDRY AND SIMILAR ROOMS SHALL HAVE NATURAL VENTILATION NOT LESS THAN 1/20 OF THE FLOOR AREA OR 1.5 SQ.FT. OR PROVIDE MECHANICAL VENTILATION WITH A MIN. OF 5 AIR CHANGES PER HOUR. DISCHARG POINT SHALL BE 3' FROM NEAREST OPENING. 4. BEDROOMS MUST HAVE AT LEAST ONE OPERABLE WINDOW OR DOOOR APPROVED FOR EMERGENCY ESCAPE OR RESCUE WHICH SHALL OPEN DIRECTLY TO AN OPEN YARD. THE MIN. NET CLEAR AREA OF THE WINDOW SHALL HAVE 5.7 SQ.FT. WITH A MIN. WIDTH OF 20" AND A MIN. HEIGHT OF 24". THE MAX. SILL HEIGHT IS 44" ABOVE FINISHED FLOOR. 5. EVERY DWELLING ROOM SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF 70 DEGREES AT ANY POINT X ABOVE THE FLOOR. 6. A DOOR IS NOT PERMITTED FROM THE GARAGE TO ANY BEDROOM. 7. EXTERIOR DOORS REQUIRE AN EXTERIOR LIGHT FIXTURE AND A LANDING. 8. WHEN APPLYING STUCCO OVER PLYWOOD, THE MOISTURE BARRIER SHALL CONSIST OF TWO LAYERS OF GRADE "D" PAPER, MINIMUM. 9. SMOKE DETECTORS SHALL BE INSTALLED IN AREAS GIVING ACCESS TO SLEEPING ROOMS ON OR NEAR THE CEILING, IN EACH SLEEPING ROOM, IN EACH STORY OF A MULTIPLE STORY DWELLING AND WHERE CEILING HEIGHT EXCEEDS THE HALLWAY HEIGHT BY 24." HARDWIRED/BATTERY BACKUP/AUDIBLE ALARM. 10. HABITABLE SPACES SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 71-641. ALL OTHER ROOMS SHALL HAVE A MIN. CEILING HEIGHT OF T-0" t. t.. • 1 1• •.i'•• t:• •• 1 t 17 • +� t r � r -� t i t : --• i t r- y i♦ ti j r •y • i t -• i i t r t.i.i , r•• i i ��• •- :t # r. .r. el solia i on ui I, 10113 gom Wel 1:77 1 MET 211 i • r 111 'r• +1 1 *4161 ITAN -N0 •'r w Lei 1 00 ■ r:. a •rrrr r ' INSULATION: 1. CONTRACTOR SHALL POST THE INSULATIONCERTIFICATE • AND y i `I t:. ! t i an Rv r r! SECURITY NOTES: 1. SLIDING GLASS DOORS AND WINDOWS LESS THAN 16 FT ABOVE ANY SURFACE AVAILABLE FOR USE BY THE PUBLC SHALL BE CAPABLE OF BEING LOCKED SECURELY. MOVABLE PANELS SHALL NOT BE EASILY REMOVED FROM THE FRAME. , •' .r i•r r i t 4srt i• y OCCUPANT HAS A VIEW OF THE AREA IMMEDIATELY OUTSIDE WITHOUT OPENING THE irr' ' irr' VIEWER, i VIEWPORT,ii OR OTHER OPENING MAYPROVIDE 3. EXTERIOR WOODEN DOORS SHALLBE SOLID CORE CONSTRUCTIONOR SHALL BE COVERED • iE FACE WITH 16 GAUGE METAL ATTACHED WITH SCREWS AT 6 INCH ON CENTER AROUND THE PERIMETERS. 4. ALL SWINGING DOORS SHALL BE EQUIPPED WITH A DEADBOLT WITH A MIN. THROW OF ONE AND EMBEDMENT OF r THAN INACTIVE5. THE t OF k PAIR OF DOORS ,x THE UPPERt OF t DUTCH r••- SHALL BE EQUIPPED' ri:r 6. NON -REMOVABLE PINS SHALLBE USED IN PIN TYPETHAT ARE ACCESSIBLE FROM OUTSIDE DOOR IS CLOSED. 7. UNFRAMED GLASS DOORS SHALL TEMPERED GLASS NOT t 8. NARROW FRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN GLASS9. ANY t LOCATED WITHIN t} OF r DEVICE ON i rrr• SHALL BE FULLY TEMPERED OR HAVE APPROVED METAL BARS, SCREENS OR DOORS. 10. SOLID WOODEN HATCHWAYS LESS THAN 1-3/4 INCHES THICK SHALL BE COVERED ON THE INSIDE WITH 16 GAUGE SHEET METAL ATTACHED WITH SCREWS AT 6 INCH ON CENTERS AROUND THE PERIMETER AND SHALL BE SECURED FROM THE INSIDE WITH A SLIDE BAR, SLIDE BOLTS, AND/OR PADLOCK WITH A HARDENED STEEL SHACKLE. ALL OTHER OPENINGS LARGER THAN 96 SQUARE INCHES WITH A DIMENSIN IN EXCESS OF 8" SHALL BE SSECURED BY METAL BARS, SCREENS, OR GRILLS. (EXCEPTION: NON -OPERABLE SKYLIGHTS). 11. A DEVELOPMENT THAT INCLUDES 3 OR MORE DWELLING UNITS SHALL BE PROVIDED WITH FULLY ENCLOSED GARAGES. GARAGE SPACE FOR EACH TENANT SHALL BE SEPARATED BY PARTITIONS OF 3/8" PLYWOOD OR EQUIVALENT WITH STUDS SET NO MORE THAN 24 INCHES ON CENTER. MECHANICAL: ATTIC FURNACES AND COOLING EQUIPMENT SHALL COMPLY WITH THE FOLLOWING: - HAVE AN ELECTRICAL OUTLET AND A LIGHT FIXTURE (CONTROLLED BY A SWITCH AT THE ACCESS POINT) AT THE FURNACE. - PROVIDE A 125 V 15- OR 20-AMP RECEPTACLE OUTLET FOR SERVICE. ROCT 12 t City ot Santa Ana PLANNING DEPARTMENT NOTES ALL ROOF LINES, ROOF MATERIALDr r MATCH. 14 i LEGAL DESCRIPTION: TRACT 557 LOT 91 ADDITION TO THE TOWN OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN CITY RECORDS. A.P.N. 013-024-16 PROPERTY ADDRESS: 1226 S. SHELTON ST, SANTA ANA, CA, 92707 OWNER: STEPHANY PANLILIO 23052-H ALICIA PARKWAY, #611 MISSION VIEJO, CA, 92692 TEL: 949.378.2100 APPLICANT: CHRIS MILLER, PACIFIC MAINTENANCE & REPAIRS TEL: 714.754.4111 SITE STATISTICS PRESENT ZONING R1 EXISTING LIVING AREA 728 SF PROPOSED LIVING AREA 499 SF TOTAL LIVING AREA 1227 SF EXISTING PORCH 80 SF EXISTING GARAGE 0 SF TOTAL STRUCTURE AREA 1307 SF LOT SIZE SQ.FT. 6250 SF LOT COVERAGE 20.9% REAR YARD AREA 2816 SF FRONT HARDSCAPE AREA N/A FRONT LANDSCAPE AREA N A !a •.. HUDGINS 27587 PASEO SEGOVIA SAN JUAN CAPISTRANO, CA 92675 TEL: 949.322.7922 FAX: 949.488.8940 EMAIL: hudginsdesign@oox.net 0 0 Z> F- W U Z w0 Z W w v i ■ v ONZ vi Zi R CTU, ACCEPTED K it C ELECPARE P1 S TRICAL. P U!'A G 1 )I set of plams and iti t all tilmeS Wid It is ur WNW "urauuns Ott same wilftut City of Santa Ana. 2""Ceplance of this pt il att. {t #palum. j PROJECT WnFORMAM 11 r PROPERTY OWNER: STEPHANY PANLILIO Mission Viejo, CA. 92692 I TEL:949,378.2100 ,, l CITY PROJECT ADDRESS: ln*216'wsoE 4�TOt*k . ZONE: R1 _.m.., , - ,F APN: 013-024-16 LEGAL DESCRIPTION: TR 557 LOT 91 SUBMITTAL SET REVISION DATE SUBMITTAL NO. 1 11 OCT 2005 SUBMITTAL NO.2 SCALE: AS NOTED DATE: 10.06.05 k_- 13 DESIGNER: HUDGINS DESIGN 27687 PASEO SEGOVIA SAN JUAN CAPISTRANO, CA 92675 TEL: 949.322.7922 FAX: 949.488.8940 EMAIL: hudginsdesign@cox.net PROPERTY OWNER- STEPHANY PANLILIO 23052-H Alicia Pkwy,, #611 Mission Viejo, CA. 92692 TEL: 949.3782100 PROJECT ADDRESS: 1226 S. SHELTON ST ZONE: RI APN: 013-024-16 LEGAL DESCRIPTION: TR 557 LOT 91 ISUBMITTAL SET I REVISION SUBMITTAL NO. I SUBMITTAL NO. 2 5 SCALE: AS NOTED JOB NO: 05041 DATE: 10.06.05 DRAWN BY: S.H. WRITTEN DIMENSIONS SHALL BE VERIFIED ON THE JOB SITE. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. WINDOW SCHEDULEi MARK TYPE SIZE FINISH MATERIAL NOTES TEMP. WIDTH HEIGHT 101 A 4 -0 V-6 PAINT VYL. SLIDER OBS; see T-24 for u & schg �' 9 values Y 102 A 4'-0" 4'-0" PAINT VYL. SLIDER; see T-24 for u & schg values N 103 A 5'-0" 4'-0" PAINT VYL. SLIDER; see T-24 for u & schg values N DOOR AND FRAME SCHEDULE FIRE RATING LABEL MATCH (E) MATCH (E) MATCH (E) 2115411 NEW T24 ENERGY NOTES 1, INSULATION: HOT WATER PIPE TO BE INSULARTED FROM THE WATER HEATER TO THE KITCHEN. 2. KITCHEN LIGHTING: 50% OF ALL "WATTAGE" MUST BE HIGH EFFICACY (EG. FLUORESCENT). HIGH EFFICACY FIXTURES AND NON -HIGH EFFECICAY FIXTURES MUST BE SWITCHED SEPARATELY. 3, LIGHTING: LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND/OR UTILITY ROOMS MUST BE HIGH EFFICACY OR MUST BE CONTROLLED BY A MANUAL -ON OCCUPANCY SENSOR. 4. LIGHTING: LIGHTING IN ALL OTHER ROOMS, INCLUDING HALLWAYS, DINING ROOMS, BEDROOMS, FAMILY ROOMS, MUST BE HIGH EFFICACY; OR MUST BE CONTROLLED BY A MANUAL -ON OCCUPANCY SENSOR; OR A DIMMER. CLOSET SPACE LESS THAN 70 SQ.FT. IS AN EXCEPTION TO THIS REQUIREMENT. 5. RECESSED LIGHTS: RECESSED LIGHTS THAT ARE TO BE INSTALLED IN AN INSULATED CEILING OR CAVITY ARE REQUIRED TO HAVE: a.) A ZERO CLEARANCE INSULATION COVER (IC). b.) TO BE THAT THEY ARE AIR TIGHT c.) T OBE SEALED WITH A GASKET OR CAULK BETWEEN HOUSING AND THE CEILING. 6, OUTDOOR LIGHTING: IF ATTACHED TO A BUILDING IT MUST BE HIGH EFFICACY OR CONTROLLED BY A MOTION SENSOR WITH AN INTEGRAL PHOTOCONTROL. WALL LEGEND NEW WALL 1 HOUR SEPERATION WALL B EXISTING WALL ¢ A31 PROPOSED EXISTING A-0" 201-0" 26'-0" 14'-8„ '-4" - 13'-4" 2'-8" - 1®'_0°r I �-- 27 I--__ ------_-_.__._-----_----- _-- __ �- WM -�_ _-_._._.._..___._.__..-_.--T .-__ ..__._.--------_.-_.-- ---� S.O.V. lol \\ F c, E. 2646 E. 2646 I E. 2646 E. 2646 I F, -51 _ 48 i 17 i BEDROOM 2 I I (BEDROOM 1 /r-------� » FL. b I N. BA f (14'_0„ x IV-0") ( �(10`-0" x 11`-0") / N. BEDROOM f \ r - (14'-4" x 12'-2") 16 I I ems' W.P. G.F.L Al. G. N. L _ DRY ENT "V105 c9 / I T - -�- AIR '.... ,= 109 z S, - N. HALL ------....-- " N. H�� Q -esF� -- ---- - 000 a. - - _ N. W.I.C. I 29 - / \ Ui I y - co I N ` TH 1 N. LIVING RM. \ uJ U I i W.P.49 S , .F.L S.D. 110V L. co c�U I 4 N. CHEN iv I W LIL I ' N. BEDROOM 3 28 " :Y-:£ 15 f (10'-2" x 10'-6") <x I I _ G. .1 C �1 2 ( w o I I i 111 1 G.It� ,s. F L I Oidl, I I :a u' ;g.;s.. 3arexiw ::{_'Hi.. '•i3:4N? .. L .+, vsC:4iv:ski.NrazFa3?abN.»ya;,aiyv;,m„.; I log / E046 ----- E.2046E. - - - - - - - - - - - -- I 10'-6" Ilk'-6" 131-4" 12'-8" 20'-0" I 26'-0" 46'-0" PROPOSED EXISTING A31 1. MEANS OF EGRESS MUST BE CONTINUOUS, UNINTERUPTED AND TERMINATE IN A PUBLIC WAY OR EXIT COURT LEADING TO A PUBLIC WAY. 2. REQUIRED EXIT DOORWAYS SHALL BE NOT LESS THAN 36" IN WIDTH AND NOT LESS THAN 6-8" IN HEIGHT. UBC 1003.3.1.3a, 3. WIDTH OF HALLWAYS INSIDE DWELLING UNITS SHALL BE 36" MINIMUM WIDTH. UBC 1004.3.3.2. 4. MAXIMUM T' RISE AND MINIMUM 9" RUN, 6'-8" VERTICAL HEADROOM MINIMUM. 5. MINIMUM CLEAR WIDTH OF 36" 6. HANDRAILS TO BE 34" TO 38" HIGH. 7. THE HAND GRIP PORTION OF THE HANDRAIL SHALL BE GREATER THAN 1 1/4" AND LESS THAN 2" IN CROSS SECTIONAL DIMENSION. 8. MAXIMUM CLEARANCE BETWEEN BALUSTERS TO BE LESS THAN 4" 9. HANDRAIL END SHALL HAVE ROUNDED TERMINATION OR BENDS. 10. GUARDRAILS TO RESIST 20#/FT. HORIZONTAL LOAD AT TOP OF RAIL. UBC TABLE 16-B. MAXIMUM CLEAR OPENING LESS THAN 4" 11. GLASS GUARDRAILS REQUIRE A TOP RAIL PER UBC 2406.6 12. EXTERIOR STAIRS AND EXIT BALCONIES SHALL NOT PROJECT INTO AREAS WHERE PROTECTION OF OPENINGS IS REQUIRED PER UBC 1006.2.1 13. PROVIDE 5/8" TYPE "X" DRYWALL ON WALLS AND CEILING OF ENCLOSED USABLE SPACE UNDER STAIRWAYS PER UBC 1006.3.3.9 GENERAL NOTES 1. WINDOWS ADJACENT TO TUBS, SHOWERS AND TUB/SHOWERS, @ STAIRWAYS, OR ADJACENT TO AND WITHIN 24" OF EITHER EDGE OF DOOR SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC, PER UBC 2406.3 & 2406.4 2. SLEEPING ROOMS SHALL HAVE A WINDOW OR EXTERIOR DOOR FOR EMERGENCY ESCAPE. SILL HEIGHT SHALL NOT EXCEED 4'ABOVE THE F.F. WINDOWS MUST HAVE AN OPENABLE AREA OF AT LEAST 5.7 SQ.FT. WITH THE MINIMUM OPENABLE WIDTH 20"AND THE MINIMUM OPENABLE HEIGHT 240. THE EMERGENCY DOOR OR WINDOW SHALL BE OPENABLE FROM THE INSIDE TO PROVIDE A FULL, CLEAR OPENING WITHOUT THE USE OF SEPARATE TOOLS. UBC SEC. 310.4 3. APPLIANCE IN CONFINED SPACE: PROVIDE TWO OPENINGS INTO ENCLOSURE EACH HAVING 1 SQ. IN. PER 1000 BTU/H INPUT FREELY COMMUNICATING WITH OTHER UNCONFINED INTERIOR SPACES. MINIMUM 100 SQ.1N. EACH OPENING. PER 98 CMC SEC. 702. 4. CEMENTITIOUS BACKER BOARD TO BE USED UNDER ALL TILE WORK AT ALL SHOWERS AND BATHS TO A MINIMUM HEIGHT OF 70" ABOVE DRAIN INLET. 5. TOILET SPACES SHALL BE AT LEAST 30" WIDE, NTH AT LEAST 24" CLEAR IN FRONT OF WATER CLOSET PER SEC. 2904. 6. BASE MATERIAL BENEATH SHOWER PANS SHALL BE SLOPED TO DRAIN PER UPC SEC, 410.5. 7. ALL NEW GLAZING (FENESTRATIONS) WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED, SHOWING THE U VALUE. 8. MECHANICAL SYSTEM TO BE DESIGN BUILD - CONDENSOR AND FAU LOCATIONS TO BE DETERMINED BY DESIGN BUILD CONTRACTOR. 9. SEE TITLE 24 ENERGY CALCULATIONS FOR MIN. BTU REQUIREMENTS FOR HEATING AND COOLING SYSTEMS. GENERAL NOTES 10. PROVIDE ARC -FAULT CIRCUIT INTERRUPTERS FOR ALL NEW BEDROOM RECEPTACLES. 11. TOILETS TO BE MAXIMUM OF 1.6 GALLONS PER FLUSH. 12. PROVIDE FLUORESCENT GENERAL LIGHTING IN BATHROOMS AND KITCHENS. SWITCH TO BE THE FIRST NEAR THE DOOR. 13. LENGTH OF DRYER LINT VENT NOT TO EXCEED 14'-0" PER UMC 504.3.2. MAXIMUM 2 ELBOWS. 14. USE SHATTER -RESISTANT MATERIALS FOR SHOWER ENCLOSURE AND WINDOWS IF SILL IS LESS THAN 64' ABOVE TUB OR SHOWER FLOOR. 15, BATHROOM RECEPTACLES SHALL BE GFCI AND SHALL BE ON A SEPARATE CIRCUIT. ; pru� FLOOR PLAN NOTES NOTE: THIS KEY NOTE LIST FOR SHEETS A-2.1 & A-2.2 ONLY. KITCHEN SINK W/ GARBAGE DISPOSAL, W/ AIR GAP FOR DISHWASHER - PROVIDE UNDERSINK WATER PURIFICATION UNIT. BUILT-IN DISHWASHER (VERIFY DIMENSIONS WITH MANUFACTURER'S SPECIFICATIONS). PROVIDE AIR GAP AT SINK. 0 36" CLEAR REFRIDGERATOR/FREEZER SPACE - PROVIDE RECESSED COLD WATER BIB AND SHUT-OFF FOR ICE MAKER. NOTE: WIDTH MAY VARY WITH BUILDER UPGRADE OPTION - VERIFY. MICROWAVE - PROVIDE SEPERATE ELECTRICAL CIRCUIT. (VERIFY DIMENSIONS WITH MANUFACTURERS SPECIFICATIONS.) COOK TOP W HOOD AND OVEN BELOW (VERIFY DIMENSIONS WITH MANUFACTURER'S SPECIFICATIONS.) a TRASH COMPACTOR. DOUBLE OVEN. CUSTOM CABINETS - GC TO PROVIDE SHOP DRAWINGS. CUSTOM LINEN CABINET - GC TO PROVIDE SHOP DRAWINGS. 10 ART NICHE 11 SOFFIT ABOVE 12 HEADER ABOVE 13 LINE OF DROPPED CEILING 14 PRE-MANF. SPA TUB W/ MARBLE TILE SURROUND. CONTROL VALVES TO PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES PER UPC SEC. 4107. 15 PRE-MANF. 72"X30" SHOWERITUB WITH CERAMIC TILE SURROUND. CONTROL THERMOSTATIC VALVES TO PRESSURE BALANCED OR HE OSTTTIC MIXING VALVES PER UPC SEG. 4107. 16 LAVATORY IN BASE CABINET - GC TO PROVIDE SHOP DRAWINGS. 17 WATER CLOSET TO BE MAXIMUM OF 1.6 GALLONS PER FLUSH. MARBLE TILE SHOWER ENCLOSURE. TILE TO EXTEND FROM FLOOR 18 TO CEILING. CONTROL VALVES TO PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES PER UPC SEC. 4107. 19 SHOWER SEAT. 20 MEDICINE CABINET, 21 PAINT GRADE WOOD SHELVING. 2 2 UTILITY SINK. 23 WASHING MACHINE SPACE - PROVIDE RECESSED BOX FOR WATER AND WASTE CONNECTIONS. DRYER SPACE - PROVIDE VENT TO OUTSIDE PER UMC SEC.1903 W/ 14, LENGTH & 24 2 ELBOWS. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THE FINAL SIZE AND LOCATION OF THE DRYER VENT. 30" X 30" ATTIC ACCESS W/ MIN. 30" CLEAR HEADROOM. IF FAU IS USED, PROVIDE 25 SWITCHED LIGHT, 110V OUTLET AND 24" WIDE SOLID FLOORING TO FAU, NOT MORE THAN 2V-0" IN LENGTH. FAU IN ATTIC PER UMC 319. PROVIDE LIGHT, POWER, GAS, ACCESS AND 30" WIDE 26 WORK SPACE. PROVIDE PRIMARY CONDENSATE DRAIN TO TAIL PEICE OF LAVATORY LOCATED IN "BATH 2". PROVIDE SECONDARY CONDENSATE DRIN LINE TO OUTSIDE. VENT TO OUTSIDE AND COMBUSTION AIR PER UMC CHAPTER 7. WATER HEATER ON 4" CONC. PLATFORM PER CITY STANDARDS W/ (2) SEISMIC STRAPS - (1) TOP AND (1) BOTTOM. PROVIDE PRESSURE RELIEF VALVE W/ DRAIN 27 TO OUTSIDE. VENT TO OUTSIDE. COMBUSTION AIR PER UMC CH. 7. FINAL LOCATION OF THE WATER HEATER VENT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR AND SHALL CONFORM TO THE APPLICABLE CODES AND REGULATIONS. 28 2X6 PLUMBING WALL 29 DOUBLE -SIDED WALL HEATER. SEE T24 CALCULATIONS. OCCUPANCY SEPARATION PER U.B.C. SEC. 302.4 BETWEEN GARAGE (U-1) AND 30 LIVING (R-3) WALLS - 5/8" TYPE "X" GYP. BORD ON GARAGE SIDE OF WALLS ADJACENT LIVING AREAS FULL HEIGHT TO ROOF DIAPHRAM OR WALLS, CEILINGS AND HEADERS. PREFABRICATED 42" METEAL FIREPLACE (MAJESTIC MODEL NO. BR/BC42) W/ 31 TEMPERED GLASS DOORS, (U.L. #MH6018 VOL. 2/ICBO NER 404). HEARTH EXTENSIONS TO CONFORM TO THE CONDITIONS OF LISTINGS AND THE MANF. INSTALLATION INSTRUCTIONS PER UBC 3102.5.2 - SEE DETAIL X/X. DECK W/ STONE FLOORING ON SETTING BED OVER DEXOTEX WATERPROOF 32 MEMBRANE - SLOPE 2% TO DRAIN. 33 DECK DRAIN. GUARDRAIL 36" ABOVE HIGHEST ADJACENT F.F. SEE DETAIL X/X PER PLAN. PRE-MANF. WROUGHT IRON GUARDRAIL - GUARDRAIL TO RESIST A LATERAL 35 LOAD OF 20 POUNDS PER SQUARE FOOT PER CBC TABLE 16-B. GC TO PROVIDE SHOP DRAWINGS. 36 EXTERIOR GRADE R/S PLYWOOD CEILING. 37 WOOD GATE - SEE EXTERIOR ELEVATIONS. 38 5/8" TYPE "X" GYP. BOARD AT WALLS AND CEILING AT ENCLOSED USABLE SPACE UNDER STAIRS. 39 12" WOOD STAIR TREAD 40 ISOKERN MASONRY FIREPLACE WITH METAL FLUE - SEE TYP. DETAIL FP-01. 41 14"X6" GARAGE EXHAUST VENT SCREEN'D AND LOUVER'D 6" ABOVE GARAGE F.F. 42 CONC. PAD AND STAIR PER CITY STANDARDS. 43 FIREPLACE FLUE FROM BELOW. ® ELEC. METER - PROVIDE ACCESS DOOR TO MATCH TRIM. 45 VEGETBLE SINK W/ GARBAGE DISPOSAL 46 BAR SINK W/ GARBAGE DISPOSAL. 47 PEDESTAL SINK. PROVIDE MECHANICAL VENTILATION CAPABLE OF PROVIDING FIVE AIR CHANGES 48 PER HOUR (DUCTLESS FANS ARE NOT ACCEPTABLE IN ROOMS CONTAINING TUBS OR SHOWERS) (1203.3) EXHAUST TO EXTERIOR WITH BACKDRAFT DAMPER. APPROVED SMOKE DETECTOR PER U.B.C. SEC. 310.9.1. DETECTOR TO BE PERMANENTLY WIRED AND WITHOUT A DISCONNECTION SWITCH OTHER THAN `Ig THOSE REQUIRED,OR OVER CURRENT PROTECTION. ALL SMOKE DETECTORS TO BE WIRED TOGETHER FOR SIMULTANIO_PS ALARM. ALL SMOKE DETECTOR'S SHALL HAVE APPROVED BATTERY BACKUP. 5O 10" DIA. TUBE SKYLIGHT. ` iff sESIGNER: w. ,-' It 27587 PASEO SEGOVIA SAN JUAN CAPISTRANO, CA 92675 TEL: 949.322.7922 FAX: 949.488.8940 EMAIL: hudginsdesign@cox.net CH z lust, ,0 036 pe 3I# PROJECT INFORMATION' left, ROR PROPERTY OWNER: STEPHANY PANLILIO 23052-H Rhoda Pkwy., #1611 Mission Viejo, CA. 92692 TEL: 949.378.2100 iA NA PROJECT ADDRESS: 1226 S. SHELTON ST. ZONE: R1 APN: 01"24-16 LEGAL DESCRIPTION. TR 557 LOT 91 SUBMITTAL SET REVISION DATE SUBMITTAL NO. 1 11 OCT 2005 FIRST FLOOR PLAN SCALE: AS NOTED JOB05041 10.06.05 DR 15/32" CDX PLWD. OR OSB SHrG. P.1. 32/16 NAIL 8d @ 6" EDGE & 12" FIELD SECTION A SCALE: 1/4" V-011 NOTE: THIS KEY NOTE LIST FOR SHEETS A-4.1 ONLY. ROOF RAFTERS OR TRUSSES PER STRUCTURAL DRAWINGS. SHEATHING PER STRUCTURAL DRAWINGS. RIDGE BEAM PER STRUCTURAL DRAWINGS. 0 2X CEILING JOISTS PER STRUCTURAL DRAWINGS. 5.1 2X FLOOR JOISTS PER STRUCTURAL DRAWINGS. a 2X4 STUDS AT 16" O/C. 17.1 2X6 STUDS AT 16" O/C. DBL. 2X TOP PLATES. 2X P.T.D.F. SILL PLATE 10. 2X SILL PLATE 11. PROVIDE R13 BATT INSULATION AT EXTERIOR WALLS. 12. PROVIDE R30 BATT INSULATION AT CEILING. 13. PROVIDE R19 BATT INSULATION UNDER GARAGE. 14. 3/4" PLYWOOD NAIL 10d @ 6' EDGE & 10" FIELD, GLUE. 95. 1/2" DRYWALL (TYP.) 16. 2X BLOCKING 17. FLUSH BEAM WITH APPROVED HANGERS. 18. DROPPED BEAM WITH GYP BOARD OVER. 19. CONTINUOUS 4X12 BEAM 20. CONCRETE SLAB 1. BUILDING FRAMING SECTIONS REPRESENT APPROXIMATE ARCHITECTURAL RELATIONSHIPS ONLY AND DO NOT NECESSARILY REPRESENT STRUCTURAL ENGINEERING CONDITIONS, CONNECTIONS OR MATERIALS. REFER TO STRUCTURAL ENGINEERING DRAWINGS FOR ALL SUPERCEDING STRUCTURAL REQUIREMENTS. REPORT ANY DISCREPANCIES IMMEDIATELY PRIOR TO PROCEEDING WITH WORK, 2. TOP OF RIDGE, MIDPOINT OF RIDGE, PLATE HEIGHTS, NATURAL GRADE HEIGHT, AND ANY OTHER VERTICAL CONTROL DIMENSION SHOW ON SECTIONS OR ELEVATIONS ARE TO BE FIELD VERIFIED BY GENERAL CONTRACTOR WITH A STRING LINE BEFORE ERECTION OF ROOF FRAMING ELEMENTS. DESIGNER IS TO BE NOTIFIED IF THERE ARE ANY DISCREPANCIES OR CONFLICTS WITH PLANNING DEPARTMENT OR HOMEOWNER'S ASSOCIATION BUILDING HEIGHT AND/OR ENVELOPE REQUIREMENTS. GENERAL CONTRACTOR ASSUMES ALL LIABILITY AND COSTS OF LOWERING ROOF FRAMING IF STRUCTURE IS ERECTED BEFORE STRING LINE CONFIRMATIN IS COMPLETED. 3. ALL OPENINGS AROUND GAS VENTS, DUCTS, PIPES, CHIMNEYS, AND FIREPLACES AT THE CEILING SHALL BE FIR EBLOCKED WITH NON-COMBUSTABLE MATERIALS PER UBC 708.2.1(4). 4. PROVIDE FIRE BLOCKING AT 10 FOOT INTERVALS IN CONCEALED SPACES BOTH HORIZONTALLY AND VERTICALLY PER UBC 708.2.1.1. 5. REFER TO FRAMING PLAN FOR SIZE AND SPACING OF ALL STRUCTURAL MEMBERS. 6. REFER TO SHEET T-1 FOR INSULATION REQUIREMENTS. ATTIC VENT SUMMARY 1. ALL VENTS TO BE COVERED WITH 1 /4" CORROSION RESISTANT WIRE/METAL MESH (1505.3). 3. ALL VENTS SHALL BE INSTALLED SO AS TO MAKE THEM WATER -PROOF ANS WALL MOUNTED LOUVERS SHALL BE SEALED AN FLASHED WITH "MOISTOP" IN THE SAME MANNER PRESCRIBED FOR WINDOW INSTALLATIONS. 4. PROVIDE APPROVED INSULATION DAMS (BAFFLES) WHERE VENT BLOCKS ARE USED BETWEEN ROOF FRAMING MEMBERS PREVENT BEING BLOCKED BY 5. PAINT VENTS TO MATCH TRIM COLOR. ATTIC VENTILATION CALCULATIONS PER U.B.C. 1505.3 ATTIC AREA : A SQ. FT. A S.F. X 1 f 300 x 144 = B SQ. IN, AREA AREA #1 AREA #2 A ATTIC AREA 1307 ---- UNIT : SQ. FT. ) B CALCULATE REQ'D NET 627 ---- FREE VENTING AREA: ( UNIT : SQ. IN. ) PROVIDE NET FREE VENTING AREA EXISTING GABLE VENTS (24X12) 190 x 3 1 = 190 SQ. IN. = 570 GABLE VENTS (12X18) 133 x 1 ---- 1 = 133 SQ, IN. = 133 DORMER VENTS ----- 1 = 135 SQ. IN. = 0 TOTAL PROVIDED 1703 SQ. IN. ---- IF dESIGNER: HUDGINS DESIGN 27687 PASEO SEGOVIA SAN JUAN CAPISTRANO, CA 92675 TEL: 949.322.7922 FAX: 949.488.8940 EMAIL: hudginsdesign@c'ox.net 0 0 C) uJ W w 0 woo Z 0 W r") W T. W% < .�. (/) Z w 10 -r f 0 CN Z 1 vi 0. PROPERTY OWNER: STEPHANY PANLILIO 23052-H Alicia P"w , #611 Mission Viejo, CA. 92692 TEL: 949.378.2100 PROJECT ADDRESS: 1226 S. SHELTON ST. ZONE: R1 APN: 013-024-16 LEGAL DESCRIPTION: TR 557 LOT 91 SUBMITTAL SET REVISION DATE SUBMITTAL NO.1 11 OCT 2005 SUBMITTAL NO.2 ISCALE: AS NOTED JOB NO: 05041 DATE: 10.06.05 DRAWN BY: S.H MIN. CLASS WCOMPOBITION . . .. .. ............................... . . . . . . . . . . ASPHALT 5HIN6vLES INSTALL 7/5" EXTERIOR PLASTER 0/ 60 .............. ....... ... F15ER BATT INSULATION . . .......... ....... . . . . . . . . PER MANUP. REQ. MIN. PAPER BACKED Y41RE MESH 11-11 . . . . . . . . . . . . ...... . . . . . . . . . . . . . . . . . . . . 2X RAFTERS REFER 50 LB. ROOF FELT TO STRUCT. PLANSD. ........... .... . . . . . . . . . . 1/9)" THK. 3 COAT PLASTER . . ......... . FIBER BATT INSULATION 2X STUD WALL FINISH 0/ PAPER BACKED . . . . . . . . . . . . . . . . . . .11;; .............. .. .... ........ h d ... ....... —1:21, M015TOP MTL. LATH, EXTEND UNDER. .. .. . . . . . 1/5" EXTERIOR CEMENT FLASHING PAPER PLASTER Of PAPER, BACKED ........ . j,; .. . . ...... IX 50LID SHEATHING @ BOARD . . .. . . .... ..... .... AIRE LATH 0/ M015TOP .. ... . ...... OVERHANG ,1/21, PY11*0 WOOD TRIM TO MATCH FLA5HINC5 . . . ...... FIELD COMPOSITION SHINGLE STARTER STRIP _(2) 2X TRIMMER 5TUP5 24 CA. &ALV. MTL. RAIN GUTTER AT JAMB CONDITION, DESIGNER: s*u_t1;4w_s- FACTORY PRIMED AND PAINTED. 4X HEADER AT HEAD CONDITION WOOD TRIM TO MATCH HUDGINS DESIGN SUPPORT TO OCCUR @ 56" OX". PER STRUCTURAL 27587 PASEO SEGOVIA SAN JUAN CAPISTRANO, CA 92675 z TEL: 949.322.7922 O 11� FAX: 949.488.8940 26 &A. :3 EMAIL: hudginsdesign@cox.net C7ALV. MTL. DRIP 4X HEADER AT HEAD 2X CEILING FLASHING p CONDITION, (2) 2X TRIMMERS 1 T JAMB, CONDITION PER ,JOISTS NHE :r A00P TRIM TO IX A'04 OCCURS MATCH EXISTING, SLIDING ISLASS Z3 STRUCTURAL PINIS.5 w I INSUL. PER. 5FAL 4 5TAIN. POOR FRAME INSTALL PER �\/INYL. WINDOW FRAME ENERGY REPORT MFeRs 5PI=c'5- INSTALL PER MF&R'S. SPECS -,A I 2X RE5ANN FA5VA, w INT. r-IN15H— 5EE PLAN FOR Dim SEAL 4 5TAIN. REFER TO Or -TAIL Il/P01 FOR ADDITIONAL FLASHING REQUIREMENTS. REFER TO DETAIL I'VD01 FOR ADDITIONAL FLASHIN6 REQUIREMENTS. NT5 TYPIC"AL EA %v" E 1-1/211=11—oll 'Oft SL. GLZOE3. DOOR 511=11-oll WINDOW HEALwj*`/JAMB 511=11-oll 1 17 k; MAING" HE u M 5 ww VT '0*'ONV. FR'A` Agm""/JA" AB I MIN. CLA55 A COMP. V'INtL WINDOW PLYWOOD 5HT6. ol ASPHALT 5HIN6LE5 FRAME SET FLANGEO.C. PER 2x RAFTPLAN ER5 0 Ib" INSTALL PER MANUF. REG. SLIDING 6LA55 YV SEALANT - %b INSTALLATION NOTES: 0/ 50 LB. ROOF FELT DOOR FRAME INSTALL PER 15T- ATTACH 12" M015TOP FLASHING MFc7R'5. SPECS. 1Z u- 4TH FLUSH ALONG THE BOTTOM OF THE OPENING. THE LENGTH OF THE "SIMPSON" A35 @ 16" O.G. TO FALL A MIN. OF 12" BEYOND E. FLASHING MUST BE LONG ENOUGH N_ ILI THE OPENING ON BOTH SIDES 5LIVIN& SLAS5 DOOR SILL OL 50 THAT IT 15 BEYOND THE Two VERTICALS THAT ARE ATTACHED PROVIDE BITUMINOUS W -2ND IN STEP 2. COATING ON SILL FOR 12" M015TOP FLASHING PAPER 2NP, r SEPARATION OF ALUM. t :2ND- ATTACH FLASHING ALONG THE u CONCRETE OR OTHER ><11 —STAPLED To ROUGH SILL, LAP 6" 0 VERTICAL SIDES OF THE OPENING DOWN AND EXTEND b" TO EA SIDE FLUSH WITH THE EDGE, MAKING PLAN FOR DIM APPROVED MEASURE TO GYP, WOOD TRIM To MATCH SURE THAT IT'S OVER THE BOTTOM 150LATE AND PROTECT PER HORIZONTAL STRIP. LENGTH OF BOARD 0 THE FLASHING MUST BE LONG DBL. TOP PLATE E.N. U15C SEC. 2504 (C). 7/5" EXTERIOR PLASTER OVER — ENOUGH TO FALL A MIN. OF 12" GONG. STOOP. SLOPE GRADE V&O MINUTE BUILDING BEYOND THE OPENING ON TOP EXTEND PLASTER UNDER- Y—AAAY FROM DOOR PAPER AND METAL LATH AND BOTTOM 50 THAT IT 15 PAf TUCK BUILDING PAPER UNDER 7% BEYOND THE HORIZONTAL PIECE 2x STUDS a 16" O.G. 4: uj vi THA 15 ATTACHED IN STEP 4 WIN L C7 AFTER THE NINVOV415 PLACED IN THE OPENING. .—MINERAL IMPREGNATED FIBER BAIT IN5ULZ IS5RD- INSTALL THE WINDOW PLUMB AND 5GUARE SMOOTH PLASTER FIBER EXPANSION STRIP . BY PRESSING THE NAILING FLANGE FINISH, TYPIGAL MATERIALS SPECIFIED: P051TIVELr INTO A CONTINUOUS BEAD OF SHEAR NALL PER PLAN [------2X STUD WALLui 0 5TH SEALANT WHICH EXTENDS AROUND THE CONCRETE SLAB PER 5TRUCT. MOISTOP FLASHING PAPER AND BOTTOM AND VERTICAL PERIMETER OF "SUPER JUMBO TEX" 60 MINUTE PAPER THE NINVOYNI MANUFACTURED BY 4TH; ATTACH THE 4TH STRIP OF FLASHING REFER TO DETAIL III/POI FOR ADDITIONAL FLA5HIN6 REOUIRP-MENT5. Z FORTIFIBER CORPORATION LAST, OVERLAPPING AND SEALED AGAINST FORTLANP, OREGON THE FULL HEIGHT OF THE OUTER FACE OF THE TOP NAILING FLANGE WITH A AV% I oft goal AOMP& W "51TUTHENE" [OE AND INATER. SHIELD CONTINUOUS 5F_At;� OF SEALANT. CUT *-j DOOR MANUFACTURED B`i' THE TOP PIECE OF FLASHING SUFFICIENTLY TYPIC%;AL BARGE @ ®I -oil SL. UL, I] I -all =1 -oil A1101116 1 9 1-1/2 ww vw 2 C) AR. GRACE AND COMPANY LONISS, 50 THAT IT WILL EXTEND PAST THE 14 1T6 WINDOW SILL CAMBRIDGE, MASS. EDGES OF BOTH STRIPS OF 51DE FLASHING ON v■AMING, 0 HRESHOLD SHEET METAL WHERE SPECIFIED TYP. 5TH: STARTING AT THE BOTTOM OF THE WALL SECURE INDEPENDFNTSECTIONS Z SHALL BE INSTALLED PER5MACNA LAP THE APPROVED BUILDING PAPER OVER RECOMMENDED SPECIFICATIONS THE WEEP SCREED (WHERE OCCURS) AND OF \/ENT PIPE TOGETHER AND v J) ■ NOTE: PROVIDE SOLID BACKING UP THE WALL IN WEATHERBOARD FASHION, ANCHOR AND SUPPORT OFFSI=T5 TO SUPPORT MOISTOP PAPER. WITH A 2" MIN, OVERLAP. INSTALL THE TO ADJACENT FRAMING MAINTAINING DOOR HEADER- 7/6" EXTERIOR PLASTER 0/ VINYL AINL70N FRAME SET FIRST COURSE THAT INTERSECTS THE REQUIRED CLEARANCES uj vi STAPLE PERIMETER OF WINDOW OPENING BENEATH THE SILL STRIP SEE 5TRA UCT. PAPER BACKED WIRE MESH I FLANGE W SEALANT MOISTOP TO FRAMING MEMBERS FLASHING WITH THE 5U55EGUENT COUR5E5 11, FROM OUTSIDE EDGE TO PRE -VENT WIND DAMAGE. ABOVE APPLIED OVER THE FLASHING THRE5HOLD 1/2" 5HI 12" NIDE M015TOP FLA5HINI57 JI ANCHOR STRAPS AT UPPER PAPER, BEHIND TRIM 117th IlLg;-! /G�AND LOWER THIRDS OF FL OR 5HT'65. rw-i N VERTICAL DIMENSION OF WATER HEATER NTH .WINDOW. FLA!"jHING WATER HEATER INSTALLATION NOTES 1ST: INSTALL G.I. PAN ALONG THE BOTTOM OF THE OPENIN5 IF THE INSTALLATION 4TH 15 OVER AOOD IONS,FLOOR. SEE PAN DIAGRAM I (I FOR DIMENS 2ND: ATTACH 12" M015TOP ALONG THE VERT- ICAL SIDES OF THE OPENING, FLUSH WITH THE EDGE, MAKING SURE THAT IT 15 OVER tu E tu A PPLAN INTERIO I -LAYER BITUTHENE, BLOrv. . LAP SHPAPER IN LIE STYLEER �NITH 60 MIN 1/6" EXTERIOR PLASTER 0/ CONCRETE SLAB CASING GRADE V60 MINUTE 5LDC7 D_ < PER PLAN PAPER, AND METAL LATH. opt WOOD TRIM TO MATCH til t- (5) 2X FRAMING z I RA E31TUTHENE a/ 6.1. FLASHING 0/ STUCCO MOULD r\ INTEGRAL OR APPLIED WOOD 5TUCCO MOULD GYP. BD. INTERIOR FIN15H WOOD POOR FRAME 06Ii ju ENTRY DOOR PER D_4 POOR 50HEDULE kn PROJECT INFORMATION oiH REFER TO DETAIL 1cf/D01 FOR ADDITIONAL FLASHING REaUIREMENT5. FOR TYPICAL NOTE55EE DETAIL I AND Icl ON THIS 5HEET. PROPERTY OWNER STEPHANY PANLILIO 23052-H Alida Pkwy., #611 i ; 11 CAA Q� THE BOTTOM FL.A51­111,46. LENGTH OF ANCHOREDI U w w a ► . - a ,, -, 1. ALL DRAWINGS, SPECIFICATIONS AND OTHER WORK PRODUCT OF THE ENGINEER FOR THIS PROJECT ARE INSTRUMENTS OF THE SERVICE FOR THE PROJECT ONLY & SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE PROJECT IS COMPLETED OR NOT. REUSE OF ANY OF THE INSTRUMENTS OF SERVICE OF THE ENGINEER BY THE OWNER ON EXTENSIONS OF THIS PROJECT OR ON ANY OTHER PROJECT WITHOUT THE WRITTEN PERMISSION OF THE ENGINEER SHALL BE AT THE OWNERS RISK ANT THE OWNER AGREES TP DEFENT, INDEMNIFY & HOLD HARMLESS THE ENGINEER FROM ALL CLAIMS, DAMAGES, AND EXPENSIES INCLUDING ATTORNEYS FEES ARISING OUT OF SUCH UNAUTHORIZED REUSE OF THE ENGINEER'S INSTRUMENTS OF SERVICE BY THE OWNER OR BY OTHERS ACTING THROUGH THE OWNER. GENERAL 1. THE FOLLOWING NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS NOTED OTHERWISE. 2. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. 3. FRAMING CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE FRAMED SIMILAR TO THE DETAILS SHOWN FOR THE RESPECTIVE MATERIALS. 4. PROVIDE OPENINGS & SUPPORTS FOR MECHANICAL EQUIPMENT, DUCTS, PIPING, VENTSM ETC. AS REQUIRED. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL OPENINGS AND EQUIPMENT NOT SHOWN ON STRUCT- URAL. ALL SUSPENDED EQUIPMENT TO BE PROVIDED WITH APPROVED LATERAL BRACING. 5. ALL CONSTRUCTION AND WORKMANSHIP SHALL CONFORM TO THE 2001 CALIFORNIA BUILDING CODE (CBC). 6. CONTRACTOR MUST VERIFY ALL DIMESIONS AND SITE CONDITIONS BEFORE START WORK. ENGINEER SHALL BE NOTIFIED OF ANY DESCREPANCIES. T THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUC- TURE. UNLESS OTHERWISE SHOWN, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. OBSERVATION VISITS TO THE SITE BY FIELD REPRESENTATIVES OF THE ARCHITECT/ENGINEER SHALL NOT INCLUDE INSPECTIONS OF PROTECTIVE MEASURES OR THE CONSTRUCTION PROCEDURES REQUIRED FOR THE SAME. ANY SUPPORT SERVICES PERFORMED BY THE ARCHITECT/ENGINEER DURING CONSTRUCTION SHALL BE DISTINGUISHED FROM CONTINUOUS AND DETAILED INSPECTION SERVICES WHICH ARE FURNISHED BY OTHERS. THESE SUPPORT SERVICES PERFORMED BY THE ARCHITECT/ ENGINEER, WHETHER OF MATERIAL OR WORK, AND WHETHER PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AND IN ACHIEVING CON- FORMANCE WITH CONTRACT DRAWINGS AND SPECIFICATIONS, BUT THEY DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE AND SHALL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION. 8. CONTRACTOR SHALL NOTIFY STRUCTURAL ENGINEER OF ALL DESCREPANCIES BETWEEN NOTES AND DETAILS PRIOR TO PROCEEDING WITH WORK. 9. DESIGN, MATERIAL, EQUIPMENT AND PRODUCTS OTHER THAN THOSE DESCRIBED BELOW OR INDICATED ON THE DRAWINGS MAY BE CONSIDERED FOR USE PROVIDED PRIOR APPROVAL IS OBTAINED FROM THE OWNER, ARCHITECT/ ENGINEER AND THE APPLICABLE GOVERNING CODE AUTHORITY. 1. MANUFACTURER SHALL SUPPLY TO ARCHITECT, ENGINEER AND BUILDING DEPAR- TMENT,CALCULATIONS AND SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. ALL CALCULATIONS AND SHOP DRAWINGS SHALL BE SIGNED BY A CALIFORNIA REGISTERED PROFESSIONAL ENGINEER. SHOP DRAWINGS SHALL SHOW ALL CRITICAL DIMENSIONS FOR DETERMINING FIT TO THE BUILDING AND THE LOADS THE JOISTS ARE DESIGNED TO SUPPORT. 2. IT SHALL BE THE RESPONSIBILITY OF THE MANUFACTURER TO OBTAIN ARCHITECT AND ENGINEER APPROVAL OF CALCULATIONS AND SHOP DRAWINGS PRIOR TO FABRICATION. 3. JOISTS SHALL BE DESIGNED AND FABRICATED TO SAFELY SUPPORT ALL SUPER- IMPOSED DEAD, LIVE, WIND AND LATERAL LOADS; SPECIAL LOADING SUCH AS MECHANICAL EQUIPMENT, ECT.; AND TO ACCOMMODATE ALL SPECIAL FRAMING CONDITIONS FOR THE SPANS AS INDICATED OR REQUIRED. 4. DEFLECTIONS SHALL BE LIMITED TO THE FOLLOWING: FLOOR JOIST - LIVE LOADS ................... ........................................................... L/480 - DEAD LOAD PLUS LIVE LOAD .............. ....................................... .L/360 5. MINIMUM TOP CHORD SHALL BE 2x4 UNLESS NOTED OTHERWISE 6. ALL CONNECTORS SHALL BE ICBO APPROVED AND OF ADEQUATE STRENGTH TO RESIST ALL STRESSES DUE TO THE LOADINGS AS OUTLINED IN NOTE 3 ABOVE 7. CROSS BRIDGING AND/OR BRACING SHALL BE PROVIDED AND DETAILED AS TO ADEQUATELY BRACE ALL JOISTS. SPECIFIED BY MANUFACTURER. HEADERS74"ARALLAM "PSL" BEAMS AND NOTED1. ALL BEAMS AND HEADERS MANUFACTURED/ _NGINEERER BEAMS FROM •ACCORDANCE WI-U • • *1 >, 2. MINIMUM DESIGN PROPERTIES AS FOLLOWS: E = 2.Ox1O PSI F(b = 2900 PSI F(V) = 290 PSI 1. ALL BEAMS AND HEADERS NOTES AS "LVL" SHALL BE MANUFACTURED/ ENGINEERED BEAMS FROM TRUSS JOIST MAC MILLAN IN ACCORDANCE WITH I.C.B.O. REPORT No NER 481 2. MINIMUM DESIGN PROPERTIES AS FOLLOWS: TYPICAL: E =1,900 KSI F(b) = 2,600 KSI F(v) = 285 KSI GLUE LAMINATED BEAMS 1, ALL GLUED -LAMINATED BEAMS SHALL BE INDUSTRIAL APPEARANCE WITH EXTIOR GLUE UNLESS OTHERWISE NOTED. 2. CANTILEVERED AND CONTINUOUS BEAMS SHALL BE 23F - V8 3. SIMPLE SPAN BEAMS SHALL BE 24F - V4 4. CERTIFICATE OF INSPECTION FOR EACH GLU - LAM BEAM FROM AN APPROVED TESTING AGENCY TO BE SUBMITTED TO AND APPROVED BY THE BUILDING DEPARTMENT PRIOR TO ERECTION. 5. ALL LAMINATIONS SHALL BE 2" NOMINAL. 6. BEAMS SHALL BE CAMBERED @ MID - SPAN BETWEEN SUPPORTS AS INDICATED ON PLANS. CAMBER AT CANTILEVERED ENDS SHALL BE ZERO. DESIGN - BUILD REQUIRENENTS: 1. THE CONTRACTOR SHALL PROVIDE DRAWINGS AND CALCULATIONS NECESSARY FOR ALL DESIGN ITEMS. THE DRAWING AND CALCULATIONS SHALL BE SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF CALIFORNIA. 2. DOCUMENTS FOR DESIGN BUILD ITEMS (REFERED TO AS DEFERRED SUBMITTAL DOCUMENTS) SHALL BE SUBMITTED TO THE ARCHITECT OR ENGINEER OF RECORD, WHO SHALL REVIEW THEM WITH A NOTATION. INDICATING THAT THE FEFERRED SUBMITTAL DOCUMENTS HAVE BEEN FOUND TO BE IN GENERAL COMPLIANCE WITH THE DESIGN CONCEPT INFORMATION GIVEN IN THE CONTRACT DOCUMENT PRIOR TO SUBMITTAL TO BUILDING OFFICIAL. THE CONTRACTORS SHALL BE RESPONSIBLE FOR FORWARDING THE SUBMITTAL DOCUMENTS TO THE BUILDER OFFICIAL. RESPONSIBILITY FOR THE DESIGN PROFESSIONAL DEAL APPEARS THEREON. THE DEFERRED AND SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. 3. "DESIGN - BUILD" ITEMSIELEMENTS (AS DESCRIBED BELOW) SHALL BE DESIGNED BY OTHERS, AND THE GENERAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES AND THE ARCHITECT. THE ENGINEER OF RECORD HAS NOT DESIGHNED THESE "DESIGN -BUILD" ITEMS. DESIGN SHALL INCLUDE THE DESIGN OF THE ELEMENTS AND ITS CONNECTION TO THE STRUCTURE. SEE NOTE #4 3.1 CURTAIN WALL, WINDOW WALL LOUBRE AND GLAZING SYSTEMS. 3.2 STAIRS, HANDRAILS, GUIDERAILS, AND LANDINGS. 3.3 ELEVATOR GUIERAILS, RELATED SUPPORTS, AND CONNECTIONS. 3.4 SUPPORTS AND CONNECTIONS FOR PIPES, SPRINKLERS, AND WASTE LINES, DUCTS, CONDUITS, SUSPENDED CEILINGS, SOFFITS, LIGHTS, ELECTRICAL EQUIPMENT, AND MECHANICAL EQUIPMENT. 3.5 LADDERS, GATES, AND METAL GRATING 3.6 PRECAST ELEMENTS. 3.7 VENEER ANCHORAGE SYSTEMS. 3.8 ANY STRUCTURE THAT IS NOT SHOWN ON THE STRUCTURAL DRAWINGS BUT IS REQUIRED BY OTHER DISIPLIBES SUCH AS ARCHITECTURAL MECHANICAL, ELECTRICAL, LANDSCAPE, ECT. L 1 ►' 1. NO PIPES OR DUCTS ARE TO BE PLACED IN CONCRETE SLABS OR WALLS UN- LESS SPECIFICALLY DETAILED. 2. AGGREGATES SHALL BE NATURAL SAND AND ROCK CONFORMING TO ASTM C33 3. STRENGTH OF CONCRETE SHAL BE AS FOLLOWS: FOUNDATION 150 PCF F'C = 2,500 PSI AT 28 DAYS SLABS ON GRADE 150 PCF F'C = 2,500 PSI AT 28 DAYS WALLS, PEDESTALS 150 PFC F'C = 2,500 PSI AT 28 DAYS 4. REBAR LAP SPLICES PER DETAIL 5. SPLICES IN HORIZONTAL REBAR IN WALLS AND FOOTINGS SHALL BE STAGGERED...3" 6. MINIMUM CONCRETE COVERAGE; THE FOLLOWING MINIMUN CLEAR DISTANCES BETWEEN REINFORCING STEEL AND FACE OF CONCRETE SHALL BE MAINTAINED UNLESS NOTED OTHERWISE. SLABS ON EARTH............................................................CENTER OF SLAB CONCRETE BELOW GRADE, FORMED.......................................................3" CONCRETE BELOW GRADE, UNFORMEND ( POURED AGAINST EARTH) 7. DOWELS FOR WALLS SHALL BE THE SAME SIZE SPACING AS THE WALL REIN- FORCEMENT AND SHALL LAP WITH THE WALL REBAR AS NOTED ABOVE UNLESS NOTED OTHERWISE. 8. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 40 FOR #3 AND SMALLER AND GRADE 60 FOR #4 AND LARGER. WELDED REINFORCING STEEL SHALL CONFORM TO ASTM A706. 9. ANCHOR BOLTS, DOWELS, INSERTS, ETC. SHALL BE SECURELY TIED IN PLACE PRIOR TO THE POURING PF ANY CONCRETE OR GROUT. 10. CEMENT SHALL BE PORTLAND CEMENT CONFORMING TO ASTM C-150, TYPR U.N.Q. IN SOILS REPORT WITH A WATER/CEMENT RATIO LESS THAN 0.40 STRUCTURAL STEEL 1. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A992 2. ALL FABRICATION AND ERECTION SHALL CONFORM TO THE LATEST STANDARD EDITION OF THE AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. 3. NO FIELD CUTTING OR BURNING OF STRUCTURAL STEEL SHALL BE PERMITTED WITHOUT WRITTEN APPROVAL OF THE ARCHITECT/STRUCTURAL ENGINEER 4. ANCHOR BOLTS AND UNFINISHED BOLTS SHALL CONFORM TO ASTM A307 5. ALL WELDING SHALL BE DONE BY THE ELECTRIC ARC PROCESS USING PROPER E70xx APPROVED COATED RODS AND PERFORMED BY CERTIFIED WELDERS. ALL FABRICATION AND WELDING SHALL BE PERFORMED IN THE SHOP OF AN APPROVED FABRICATOR. WELDING MAY BE PERFORMED IN THE SHOP OF AN ARC PROCESS WITH AUTOMATIC WELDING (SAW-1). LOW HYDROGEN ELECTODES SHALL BE USED IN WELDING OF REINFORCING BARS. 6. ALL PIPE SHALL CONFORM TO ASTM A53 GRADE "B" (35 KSI) 7. ALL TUBE SHALL CONFORM TO ASTM A500 GRADE "B" (46 KSI) 8. MANUFACTURER SHALL SUBMIT COMPLETE SHOP DRAWINGS TO THE ARCHITECT/ STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL. 9. ALL STEEL SHALL BE FABRICATED BY A CODE APPROVED FABRICATOR. MASONRY 1. ALL CONCRETE BLOCK SHALLCONFORM TO ASTM C90, GRADE N-1. USE OPEN END BLOCK AS REQUIRED TO ACCOMMODATE VERTICAL REINFORCING. 2. LAP ALL BARS A MINIMUM OF 40 BAR DIAMETER (2" - 6" MINIMUM) AT SPLICES UNLESS NOTED OTHERWISE. 3. ALL MASONTY SHALL BE REINFORCED GROUTED MASONRY. GROUT SOLID ALL CELLS. 4. SPLICES OF HORIZONTAL REBAR IN WALLS SHALL BE STAGGARD. 5. DOWELS FOR WALLS AND COLUMNS SHALL BE THE SAME SIXE AND SPACING AS THE WALL OR COLUMN REINFORCEMENT AND SHALL LAP WITH THE WALL OR COLUMN REBAR AS NOTED ABOVE. 6. ALL REINFORCEMENT, BOLTSM ETC, SHALL HAVE A MINIMUM BROUT COVERAGE OF 3/4". PROVIDE 1" GROUT ALL AROUND EACH BOLT BETWEEN BOLT AND BLOCK SHELL. 7. MORTAR SHALL BE TYPE "S" AND ATTAIN A MINIMUM COMPRESSIVE STRENGTH AT 28 DAUS OF 1800 PSI AND MIXED IN THE PROPORTIONS OF 1 PART PORTLAND CEMENT TO 1/2 TO 1/4 PARTS LIME PUTTY TO 2'l2 TO 3 TIMES THE SUM OF THE CEMENT PLUS LIME PUTTY PARTS OF SAND. 8. GROUT SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS AND SHALL BE MIXED IN PROPORTIONS OF 1 PART PORTLAND CEMENT TO 1/10 PART LIME PUTTY TP 2 TO 3 PARTS SAND TO A MAXIMUM OF 2 PARTS GRAVEL/ 9. RELATIVELY NON -EXPANSIVE FILL SHOULD BE USED IN BACK FILLING BEHIND WALLS. ALL RETAINING WALLS SHALL BE ADEQUATELY SHORED DURING THE BACK FILL OPERATION. 10. ALL BRICK SHALL CONFORM TO ASTM C62, GRADE MW 11. CEMENT, REBAR, ETC. SHALL BE PER CONCRETE SECTION UNLESS NOTED OTHERWISE. 12. AGGREGATES FOR MORTAR AND GROUT SHALL BE NATURAL AND ROCK CONFORMING TO ASTM C144 AND C404. WOOD FRAME 1. ALL STRUCTURAL LUMBER SHALL NE DOUGLAS FIR OF THE FOLLOWING GRADES, CONFORMING TO STANDARD GRADING RULES FOR WEST COAST LUMBER, NO 17, UNLESS NOTED OTHERWISE: RAFTERS, AND JOISTS ............ ................... ......... ................ .......NO.2 OR BTR. BEAMS AND STRINGERS ................... ....................... ......... .................. .... NO.1 POSTSAND TIMBERS......................................................................... _ _140.1 PLATES.. .................................................................................. NO.2 OR BTR. BLOCKING, STRIPPING................................................................STUD GRADE. STUDS........................................................................PER SCHEDULE ON SD-02, 2. PLYWOOD ROOF SHEATHING SHALL BE APA RATED STR. 1, UNLESS NOTED OTHERWISE. USE EXTERIOR TYPE, MINIMUM C-C GRADE, WHERE PLYWOODIS EXPOSED TO WEATHER. PLYWOOD FLOOR SHEATHING SHALL BE APA RATED STR. 1, UNLESS NOTED OTHERWISE. ALL PLYWOOD SHALL BE GLUED WITH EXTERIOR TYPLE GLUE. ALL PLYWOOD SHALL CONFORM TO LATEST U.S PRODUCT STANDARD PS 1. INSTALL SHEATHING W/ 1/8" GAP BETWEEN SHEETS. USE T & G SHEATHING AT UNBLOCKED DIAPHRAGMS. 3. EACH SHEET OF PLYWOOD SHALL BE IDENTIFIED BY A REGISTERED STAMP OR BRAND OF THE AMERICAN PLYWOOD ASSOCIATION 4. ALL PLYWOOD NAILS SHALL BE COMMON. NAILING SHALL BE PER CHAPTER 23 OF THE U.B.C. 5. UNLESS NOTED OTHERWISE ALL NAILS USED IN CONSTRUCTION OF THIS PROJECT SHALL BE COMMON NAILS AND CONFORM TO: PENNY PENETRATION DIAMETER WEIGHT (INCHES) (INCHES) 8d 1 1/2 0.131 10d 1 5/8 0,148 16d 1 3/4 0.162 20d 2 1 /8 0.192 6. USE OF MACHINE NAILING IS SUBJECT TO A SATISFACTORY JOB SITE DEMONSTRATION FOR EACH PROJECT AND THE APPROVAL BY THE PROJECT ARCHITECT OR STRUCTURAL ENGINEER. THE APPROVAL IS SUBJECT TO CONTINUED SATISFACTORY PERFORMANCE. MACHINE NAILING WILL NOT BE APPROVED IN 5/16" PLYWOOD, IF NAIL HEAD PENETRATE THE OUTER PLY MORE THAN WOULD BE NORMAL FOR A HAND HAMMER OR IF MiNIMYM ALLOWABLE EDGE DISTANCE ARE NOT MAINTAINED THE PERFORMANCE WILL BE DEEMED UNSTATISFACTORY. 7. ALL BEAMS SHALL HAVE POST OR MULTIPLE STUDS BELOW w/ SIMPSON "PC" OR'i CAP, TYPICAL U.N.O. 8. PROVIDE SIMPSON "LU" HANGERS AT ALL JOIST CONNECTIONS 9. PROVIDE SIMPSON "HU" HANGERS AT ALL BEAM CONNECTIONS, TYP. U.N.O. 10. PROVIDE SOUBLE JOISTS UNDER PARTITIONS WHICH ARE PARALLEL TO THE JOISTS. 11. PROVIDE SOLID FULL DEPTH BLOCKING UNDER PARTITIONS WHICH ARE PERPENDICULAR TO THE JOISTS. 12. ALL WOOD BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED DOUG FIR. 2 13.10P PLATE OF ALL STUD WALLS SHALL BE 2 PIECES THE SAME SIZE AS STUDS. SPLICES TO LAP 4'-0" MIN. AND BE NAILED WITH 16-16d MINIMUM EACH SIDE OF JOINT. 14. PROVIDE 1 X 6 DIAGONAL LET - IN BRACING (AT APPROX. 45 DEGREES) EVERY 25' - 0" MAX. IN ALL STUD WALLS NOT PLYWOOD SHEATHED. BRACING SHALL RUN CONTINUOUS FROM SILL PLATE TO TOP PLATE. NAIL WITH 2 - 8d PER STUD AND 3 - 8d EACH END TO PLATES. 15. PROVIDE 2X SOLID BLOCKING BETWEEN JOISTS AND RAFTERS AT ALL SUPPORTS. BLOCKING SHALL BE ONE PIECE AND THE FULL DEPTH OF THE JOIST OR RAFTERS. 16, PROVIDE FIRE STOPS AT ALL INTERSECTIONS OF STUD WALLS AT FLOOR, CEILING AND ROOF. FIRE STOPS SHALL BE 2X NOMIINAL THICKNESS OF WOOD AND SHALL BE THE FULL WIDTH OF THE ENCLOSED SPACE. PLACE FIRE STOPS AT A MAXIMUM SPACING OF 8' - O" IN THE VERTICAL DIRECTION. PROVIDE 2X FIRE STOPS INA ALL FURRED SPACES, VERTICAL AND HORIZONTAL, AND AT MAXIMUM SPACING OF 8'- 0" IN EACH DIRECTION & AT THE SAME LINES AS FIRE STOPS IN ADJACENT STUD WALLS. 17. CROSS BRIDGING SHALL BE PROVIDED AT 8'- 0" O/C MAXIMUM FOR ALL JOISTS AND RAFTERS MORE THAN 8" DEEP. 18. STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, ECT. UNLESS SPECIFICLY DETAILS. 19. BOLT HOLES IN WOOD SHALL BE 1/32" TO 1/16" LARGER THAN THE NOMINAL BOLT DIAMETER. ALL BOLTS SHALL HAVE STANDARD CUT WAHSER UNDER HEAD AND NUT UNLESS NOTED OTHERWISE. 20, ALL BOLTS SHALL BE RETIGHTENED PRIOR TO THE APPLICATION OF SHEATHING PLASTER, ECT. 21. STUDS MAY BE BORED TO 20 % OF WIDTH MAX EXCEPT INTERIOR NON -BEARING STUDS WHICH MAY BE BORED TO 60 % OF THE WIDTH MAX, BORED HOLES SHALL BE LOCATED @ CENTER OF STUD WIDTH. FYIiL�C#�*1v = _ • = # _ _ sti7c��a=T�fl�i.f�i7eT7Ii�IRa :«1�I �iliL�If1I13�s�3+i;L�1ij� SIZE SPACING MAX. SPAN PLASTER MAX. SPAN GYP BD 2x4 16" O.C. 8' - 0" 10, - 0" 2x6 16" O.C. 12' - 0" 15' - 0" 2x8 16" O.C. 16' - 0" 20'-0' BRIDGING TO JOIST TOE NAIL EACH END ................. ...... .................................. ........ ......2-8d 1" X 6" SUB FLOOR OR LESS TO EACH JOIST, FACE NAIL. . .................. ...... . ................... 2 - 8d WIDER THAN 1"X 6" SUB FLOOR TO EACH JOIST, FACE NAIL. . .......... .......................... 3 - 8d 2" SUB FLOOR TO GIRDER, BLIND AND FACE NAIL ....... ..... ................... ........ ............. .....2-16d SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL.............................................16d AT 16" O.C. TOP PLATE TO STUD, END NAIL ............ ....... ....... ....... ........... ......... ............ ........... ....... 2-16d STUD TO SOLE PLATE .................. ....................... ............................................ ............. 4- 8d DOUBLED STUD FACE NAILS............................................................................16d AT 24" O.C. DOUBLED TOP PLATES. FACE NAILS...............................................................16 d AT 16"O.C. TOP PLATES, LAPS AND INTERSECTIONS, FACE NAIL. ........ .................................. . _.2- 16d CONTINUOUS HEADER, TWO PIECES.................................................2 ROLLS 16d AT 16" O.C. CONTINUOUS HEADER TO STUD, TOE NAIL. - _ . ..... ....... ........ .__ ........................ 4- 8d CEILING JOIST TO PARALLEL RAFTERS, FACE NAIL .................. ......... ............ ................ 3-16d 1" X 8" SHEATHING OR LESS TO EACH BEARING, FACE NAIL ..... .............. ....... .................. 2- 8d WIDER THAN V X 8" SHEATHING TO EACH BEARING, FACE NAIL ......... .......... ................. ..3-8d 1" BRACE TO EACH STUD AND PLATE, FACE NAIL .... ........................................... .... ....... .2- 8d BUILT UP CORNER STUDS.... . ....................... ......................................... __ .... 16d AT 24" O.C. BUILT UP GIRDER AND BEAMS.........................................................................20d AT 32" O.G. AT TOP AND BOTTOM AND STAGGARD..........................................................................2-20d AT ENDS AND AT EACH SPLICE 2" PLANKS........................................................ ......................................... .................. 2-16d AT EACH BEARING JOIST OR RAFTERS TO SIDES OF STUDS EIGHT (8) - INCH JOIST OR LESS. ..... ................................... . ................ .......... 3- 16d FOR EACH ADDITIONAL FOUR (4) INCHES IN DEPTH OF JOIST .................... ............... 1-16d... JOISTS OR RAFTERS AT ALL BEARINGS, TOE NAILS, EACH SIDE ... 2........... ..................... ..2-10d BLOCKING BETWEEN JOISTS OR RAFTERS TO JOISTS OR RAFTERS - TOE NAILS, EACH SIDE, EACH END .................. ____ ......... 2-10d TO JOIST OR RAFTER BEARING - TOE NAILS, EACH SIDE ............. .............. ............... 3-10d BLOCKING BETWEEN STUDS, EACH END ..... ........... ......................... 2-1Old TOE NAILS OR 2-16d RIBBONS TO STUDS ONE (1)-INCH RIBBONS ......... ......... .................... .................... ....... ..................... ........... 2-Bd TWO(2) - INCH RIBBONS ................................................... ..... .............. ........... .......... ....2-16d ;F< III �I 1 Z Lei 0C. ffl1 0m, I Leil 27587 PASEO SEGOVIA SAN JUAN CAPISTRANO, CA 92675 TEL: 949.322.7922 FAX: 949.488.8940 EMAIL: hudginsdesign@cox.net ROPERTY OWNER: STEPHANY PANLILIO 23052-H Alicia Pkwy., #611 Mission Viejo, CA. 92692 TEL: 949.378.2100 PROJECT ADDRESS: 1226 S. SHELTON ST ZONE: R1 APN: 013-024-16 LEGAL DESCRIPTION: TR 557 LOT 91 SUBMITTAL SET REVISION DATE SUBMITTAL NO. 1 11 OCT 2005 SUBMITTAL NO.2 13 L iCALE: AS NOTED •: NO: 05041 FOUNDATION 1-1 PAD SCHEDULE TYPE AREA DEPTH REFORCING FOOTING(:D TYPE SIZE REFORCING F-1 12" WIDE X 12" DEEP (1)#4 BAR TOP & BOTTOM WRITTEN DIMENSIONS SHALL BE VERIFIED ON THE JOB SITE. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. FOIJNI�)ATION NOTE:5 I. FOUNDATION EXCAVATIONS a REINFORCEMENT SHALL BE EXAMINED $ GERTIFIED IN NRITING BY THE PROJECT GEOLOGICAL ENGINEER PRIOR TO INSPECTION BY BUILDING OFFICIAL AND PLACEMENT OF CONCRETE. 2. THERE SHALL BE NO TRENCHES OR EXCAVA- TIONS 5-0" OR MORE IN DEPTH INTO NHIGH A PERSON IS REQUIRED TO DE5GEND. OBTAIN PERMIT FROM GA DIV. OF INDUSTRIAL SAFETY PRIOR TO ISSUANCE OF GRADING PERMIT. 3. PLASTER WEEP 5GREED5 TO BE MIN. 26 GA CORROSION RE515TANT METAL wl MIN. 3 112" VERT. ATTACHMENT FLANGE. 56REED5 TO BE MIN. 4" ABOVE FIN. GRADE OR 2" ABOVE PAVED 5URFAGE5. LAP WEATHER BARRIER wl EXT. LATH COVER 4 TERMINATE ON FLANGE. PER U.B.G. SECTION 2506.5 4. REFER TO ANCHOR BOLT NOTE FOR BOLT 51ZE � 5PA6ING B SILL THICKNE55 @ SHEAR NALL5. 5. NOT USED. 6. WOOD MEMBERS IN CONTACT wl CONCRETE SHALL BE PRESSURE TREATED DOUGLAS FIR (P.T.D.F.) OR FOUNDATION REDWOOD wl MARK OR BRAND FROM APPROVED AGENGY, PER U.B.G. SECTION 231-7.4 a 2326.6 -7. FLECTRIGAL OUTLET LOCATIONS IN CONCRETE SLABS SHALL BE VERIFIED wl OWNER. b. FOR HOLDONN5 @ FOOTIN65 SEE DETAIL: HOLDDONN HARDWARE TO BE SEGURED IN PLACE PRIOR TO FOUNDATION INSPECTIONS. G. STRUCTURAL OBSERVATION PER SECTION 1-702 OF THE GBG SHALL BE PROVIDED WHEN 50 DE5I6NATED BY THE ARCHITECT OR ENGINEER OF RECORD OR, WHEN SUCH OBSERVATION 15 SPECIFICALLY REQUIRED BY THE BUILDING OFFICIAL. ANOHOR E30LT NOTE TYPICAL NON -SHEAR WALL ANCHOR BOLTS SHALL BE 5AY' DIA. w1 2" SO. X 3\16" THK NA5HER5 @ 4b"O,C. ALL ANCHOR BOLT EMBEDMENT TO BE MINIMUM 7" INTO FOOTING BEYOND GOLD JOINT. SILL PLATES SHALL HAVE MIN. 2 ANCHOR BOLTS wl ONE BOLT WITHIN 12" OF EACH END OF SILL. NUT wl MASHER SHALL BE TIGHTENED ON EACH BOLT TO THE SILL PLATE PER U.B.G. SECTION 1506.6 NON -SHEAR NALL INTERIOR FOOTINC75 MAY HAVE "RAMSET" 1l4" DIA. SHOT PINS @ 24" D.G., I.G.B.O. NO. 163G, OR APPROVED EQUAL. 5HOT PIN EMBEDMENT TO BE MINIMUM 1 112" INTO CONCRETE. ALL BOLT HOLES SHALL BE DRILLED 1152" TO 1116" OVERSIZED. APPROVED PLATE NA5HER5 REQUIRED FOR ALL HOLD-DONNS CONNECTOR BOLTS. HOLD-DONN5 TO BE TIGHTENED JUST PRIOR TO COVFRING THE NALL FRAMING. FOUNDATION ANCHOR BOLTS IN WALLS SHALL HAVE AN APPROVED PLATE MASHER UNDER EACH NUT AND THE NUTS SHALL TO BE TIGHTENED JUST PRIOR TO COVERING THE NALL FRAMING. ANCHOR BOLT 5PAGING AT SHEAR NALL5 SHEAR ANCHOR BOLT 51ZE $ 5PAGIN6 WALL# wl MIN. 2x PTDF SILL Ae, 518" DIA. ANCHOR BOLTS @ 54" O.G. A518" DIA. ANCHOR BOLTS @ 36" Q.C. A518" DIA. ANCHOR BOLT5 @ 24" O.G. ANCHOR BOLT SPACING AT SHEAR NALL5 SHEAR ANCHOR BOLT SIZE 4 SPACING NALL# wl MIN. 3x PTDF 51LL !f 518>° DIA. ANCHOR BOLTS @ 16" O,G. i2 3l4" DIA. ANCHOR BOLTS @ 24" O.G. A314" DIA. ANCHOR BOLTS @ 24" O.G. A3/4" DIA. ANCHOR BOLTS @ 16" O.G. NHERE SHEAR PANELS OCCUR ON BOTH SIDES OF A NALL ANCHOR BOLT 5PAGIN6SHALL BE HALF THAT SPECIFIED IN TH15 SCHEDULE. FOR EXIST. FTC. USE "SIMPSON" EPDXY ET WI MIN. 6" EMBEDMENT WI INSPECTION, FOR 51ZF AND SPACING OF BOLTS SEE ANCHOR BOLT NOTE ABOVE. 1, ALL STUDS SHALL BE SPACED @ 16" D.C. 2. ALL STUDS AND TOP PLATES AND ANCHOR SILL'S AT WALL #'5 10,11,12,13,$14 KITH SHEAR 350 P.L.F. a GREATER SHALL BE 3X OR HIDER AT PANEL JOINTS AND SILL AT FTG.'5. 3. ALL NAILS FOR PLYWD SHALL BE COMMON NAILS U.N.O. 4, ALL NAILS SHALL BE STAGGERED NHERE NAILS SPADED 2 INGHE5 O.G. 5. ALL LAG BOLTS SHALL HAVE 1.5" MIN. EMBEDMENT INTO SUPPORTING MEMBERS. 6. ALL 20d NAIL HOLES SHALL BE PREDRILLED. `i`. ALL PLATE MASHERS FOR SILL ANCHOR BOLTS SHALL BE MIN. 2" 50. X 3116" THK. AND USED ON EACH BOLT. 8. FOR ANCHOR BOLT LENGTH, REFER TO FOUNDATION DETAILS. ALL ANCHOR BOLTS SHALL HAVE 7" MIN. EMBEDMENT FROM FIRST POUR. is DESIGNER: HUDGINS DESIGN 27587 PASEO SEGOVIA SAN JUAN CAPISTRANO, CA 92675 TEL: 949.322.7922 FAX: 949.488.8940 EMAIL: hudginsdesign@cox.net PROPERTY OWNER: STEPHANY PANLILIO 23052-H Alida Pkwy, #611 Mission Viejo, CA. 92692 TEL: 949.378.2100 PROJECT ADDRESS: 1226 S. SHELTON ST. ZONE: R1 APN: 013-024-16 LEGAL DESCRIPTION: TR 557 LOT 91 REVISION DATE SUBMITTAL NO. 1 11 OCT 2005 SUBMITTAL NO.2 FOUNDATION PLAN SCALE: AS NOTED JOB NO: 05041 DATE: 10.06.05 DRAWN BY: S.H . • c "= WRITTEN DIMENSIONS SHALL BE VERIFIED ON THE JOB SITE. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. -t -•---------- { I 4X6 HDR. t---------------: (TYP) ADDITION i EXISTING ( -------------_.----) E. I E. E. 1 E. E r-.._--__.___._-___.--___.------_..- -------- EXISTING E. 1ST F a FRAMING"' A SCALE: 1 /4" = 1' - 0" HANOER GEILIN6 JOI5T5 "SIMPSON" HANGER J015T SIZE JOIST SPAN FACE TOP 2x12 < 26-0" U210 J8212 2xIO < 24'-0" LU2b JB210 2xb < 21'-0" LU526 JB25 2x6 < Ib"-O" LU526 JB26 2x4 <10-0'" U24 HU24TF H,AN6l=R SPEC I F I GAT I ONS ROOF RAFTERS "51MP5ON" HANGER JOIST 51ZE JOIST SPAN FACE TOP 2x12 < 23'-0" U210 J6212 2x10 < Iq-0" LU25 JB210 2xb < 15-0" LUS26 JB25 2x6 < ll'-O" LU526 JB26 HANGER5 TO BE 5KEWED/51-OPED AS REQUIRED HANGER F(::., I F I GATI ON5 FLOOR JOISTS "SIMPSON" HANGER JOIST 51ZF J015T SPAN FACE TOP STEEL TJI PR0550 < 25-0" MIU4q ITT411.8b ITT411.25 TJI PR0250 < 20"-0" IUTII ITTi1.bb ITTI1,25 2x12 OJ < 15'-O" U210 J6212 JB210 2x10 DJ < 10'-O" LU528 JB210 L525 ROOF SHTG. TO BE 1/2" EXTERIOR GRADE PLYWOOD (32/16) wl Cad @ 6" O.G. BOUNDARIES 4 PANEL EDGE5, � bd @ 12" O.G. IN FIELD. U.N.Q. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE GOVERING. FACEORAiN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. THE UNINCORPORATED AREA OF THE COUNTY 15 CONSIDERED TO BE A "SPECIAL WIND RE010N." ALL ROOF FASTENERS SHALL BE INSTALLED PER MANUFACTURER'5 INSTRUCTIONS. ALL FASTENERS TO RE515T WIND LOAD OF NOT LE55 THAN 970 MPH O.G. BLDG, ORD, #3Pbq SEE DETAIL: 15/0-12 ROOFING MANUFACTURER TO PROVIDE SAMPLES OF COLORS AT JOB SITE FOR OWNER AND D.C.A. APPROVAL PRIOR TO ORDERING OF MATERIALS. PROVIDE O.I. METAL FLASHING AT ALL ROOF $ WALL INTERSECTIONS. PROVIDE G.I. METAL FLASHING AT ALL VALLEYS. SEE GENERAL NOTES SPECIFICATIONS FOR ADDITIONAL FRAMING MATERIALS NOTES. ALL RIDGE HEIGHT5 ARE TO TOP OF FINISH ROOFING MATERIALS. HATCHINO INDICATES "CALIF." ROOF FRAMING. SHADED AREAS INDICATE INTERIOR BEARING WALL5, BEAM5 OR FULL HT, SHEAR WALL5 BELOW. PROVIDE 2x6 KI6KER5 FROM BEARING POINTS 4 WALL5 BELOW TO HIPS, VALLEYS d RIDGE5 @ 45 DEG. ANGLE MIN. TT I C V'F-NT NOT SEE SHEET A-4.1 FOR ATTIC VENT NOTES G `172 BEARINIS WALLS 2x4 5TUD5 @ 16" O.G. MAX. HT.: 10'-0" 3x4 STUDS cap Ib" O.G. MAX. HT.: 10'-0" 2xb STUDS @ 16" O.G. MAX. HT.: W-O" 2xb STUDS @ 16" O.G. MAX. HT.: 16-0" NON -BEARING WALL5 2x4 5TUD5 @ 16" O.G. MAX. HT.: W-O" 2x3 STUDS @ 16" O.G. MAX. HT.: 14"-O" 2x6 5TUD5 @ 16" O.G. MAX. HT.: 20'-0" UTILITY GRADE STUDS SHALL NOT BE SPACED MORE THAN 16" O.G., OR 5UPPORT MORE THAN ONE ROOF AND GEILING, OR EXCEED b'-O` IN HEi6HT FOR EXTERIOR AND LOAD BEARING WALL5, OR 10'-0" IN HEI6HT FOR INTERIOR NON -BEARING WALL5. ALL PLUMBING WALLS TO BE 2 x b STUD5 MIN. STUD MAX. HEI6HT5 PER U.B.G. TABLE 23-1-R-3 LF-OFEND SHEAR PANEL PER SCHEDULE ZEN61NEEP-5 SHEAR WALL # PER S.W. STRUCTURAL CALCULATIONS L-- - PANEL LENGTH A -MOMENT FRAME SHEAR PANEL SHEAR PANEL LOCATION # BEAM ELEVATION PER SCHEDULE ON PLAN BEAM # PER ENOINFERB CALG5. 5EAM/J015T LINE X- BEARING POINT FROM ABOVE ON BEAM JOIST/RAFTER SPAN, TYPE AND SIZE PER SCHEDULE (-- CANTILEVERED JOISTS 2xb 5TUD5 @ 16" O.G. INTERIOR BEARING WALL CONTINUED P05T FROM ABOVE //yA >3 BUILDING SECTION REFERENCE LETTER 12 BUILDING SECTION SHEET NUMBER 2 DETAIL REFERENCE NUMBER 04 DETAIL SHEET NUMBER 1. USE "SIMPSON" HANGERS OR APPROVED EQUAL AT JOISTS, HANOI NG FROM BEAMS, AND AT ALL BEAM TO BEAM CONNECTIONS PER PLAN. 2. BEAMS AND HEADERS LARGER THAN 4xI0 TO BE SUPPORTED AT EACH END WITH A 4x P05T OR LARGER, BEAMS AND HEADERS 4x10 OR SMALLER TO BE SUPPORTED AT EACH END BY DOUBLE 5TUD5 EXCEPT AS, NOTED ON PLANS. 3. PROVIDE "TJI-550" OR EQUAL BELOW WALL5 EXCEPT AS, NOTED OTHERWI5E ON PLANS @ COMPOSITE TRU55 FLOOR FRAMING. PROVIDE "TJI" BLOGKING BELOW WALL5 PERPENDICULAR TO JOISTS. 4. PROVIDE DOUBLE JOISTS BELOW NON -BEARING, AND TRIPLE JOISTS BELOW BEARING WALLS EXCEPT AS, NOTED OTHERWISE ON PLANS @ 2x 5TANDARD FLOOR FRAMING, BOND 2x'5 WITH 2-16d R.5. NAILS @ 24" O.G. ALTERNATE 51DES. 50LID BLOCK BELOW WALL5 PERPEN- DIGULAR TO JOISTS. 5, FIREBLOGK ALL DROPPED AND SOFFITED GEILiN05, TYPICAL. 6. PROVIDE RAFTER TIES @ 45" O.C. IN LOWER 1/3 OF ATTIC SPACE WHERE GEILINO J015T5 ARE NOT PARALLEL TO ROOF RAFTERS. 7. ALL FRAMING HARDWARE TO BE "5IMPSON STRONG TIE INC." OR APPROVED EQUAL. b. WHERE OBL, TOP PLATES ARE BROKEN OR INTERRUPTED PROVIDE MIN. I/b" THK.x 1-1/2" WIDE METAL TIE STRAPS. LAP ALL TOP PLATE 5PLIGE5 MIN. 4'-0". q. ALL UNSPECIFIED HEADERS TO BE MIN. 4x4. 10, ALL P05T5 4x4 AND LARGER TO HAVE "SIMPSON" A-35 EAr-,H 51DE OF POST TO TOP AND BOTTOM PLATES U.N.Q. ON PLANS. 11. ALL PLUMBING WALL5 TO BE MIN. 2xb STUDS. 12. GLUED -LAMINATED BEAMS SHALL BE MARKED ANSI/AITC STANDARD AlgO.l. 13. PROVIDE FIELD INSPECTOR WITH APPROVED "CERTIFICATION OF INSPECTION" FOR ALL GLUED -LAMINATED BEAMS. 14. ALL UPPER FLOOR SHEAR PANELS AND BEARINO WALL5 TO EXTEND TO ROOF FRAMING MEMBERS. 15. WHERE SHEAR WALLS ARE CONTINUOUS ACROSS, OTHER WALL5, POPOUTS OR FURRING, APPLY SHEAR PANEL PRIOR TO OTHER FRAMING TO PRESERVE SHEAR WALL CONTINUITY. lb. STRUCTURAL OBSERVATION PER SECTION 1702 OF THE GBG SHALL BE PROVIDED WHEN 50 DESIGNATED BY THE ARCHITECT OR ENGINEER OF RECORD OR, WHEN SUGH OBSERVATION 15 SPECIFICALLY REQUIRFD BY THE BUILDING OFFICIAL. 17, LA6 BOLTS: PROVIDE LEAD HOLE 40% - 70% OF THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH SHANK PORTION. SHEAR. PLYYIOOD # NAILING PER ALLOWABLE SILL -NAILING WALL # U.B.G. TABLE 23-1-K-1 SHEAR -7/b" 5TUGGO 0/ PAPER A8BAGKED LATH w/ Ib 6A. STAPLES @ 6110.6. AT T E B 180 PI F 16d @ 6"` O.G. PLATES, EDGE OF SHEAR WALL AND ON FIELD A10 3/b" STRUGT. If PLYWD. w/ bd @ b"O.G. BOUND. s 260 PLF Ibd @ b" O.G. EDOF5 4 12"O.G. FIELD 3/8" 5TRUGT. 11 PLYWD, II w/ 5d @ 4"O.G. BOUND. s 3461 PLF Ibd @ 4" O.G. EDOE5 a 12"O.G. FIELD 515" 5TRUGT. 11 PLYWD. 20d @ 3" O.G. w/ Fad @ 3'"O.G. BOUND. 8 4,40 PLF OR Ill" DIA. LAG A G EDGE5 4 12"O.C. FIELD BOLTS AT 16" O.G. A 3/Fa"5TRUGW T. 11 PLYD. 20d @ 2-1/2" O.G. w/ bd @ 2"O.G. BOUND. 6 650 PLF OR 112'" DIA. LA6 ED&E5 $ 12'"O.C. FIELD BOLTS AT 12" O.G. 15/32" 5TRUGT. 11 PLYWD. 20d @ 2 " O.G. w/ iOd @ 2"'O.G. BOUND. 4 770 PLF OR 112" DER. LA6 A 6 EDGE5 k 12"O.G. FIELD BOLTS AT 10" O.G. iq/32" 5TRUGT. 11 PLYWD. 20d @ 2" O.G. w/ IOd @ 2"0.6. WUND. 4 &-70 PLF OR 1/2" DIA. LA6 A 6 ED6E5 4 12"O.G. FIELD BOLTS AT 6" O.G. AINDIGATFS SHEAR WALL NOT � INCLUDED IN 5TRUGT. DE516N FOR SHEAR PANELS 11, 12, 13 1 14 PROVIDE MIN. 3x BOUNDARY MEMBERS 4 SILL PLATE (35OPLF) w/ 5TA66ERED NAILING @ BOUNDARIES 4 E06E5. THE -MAX. HE16HT TO WIDTH RATIO FOR SHEAR WALL5 15 2:1 UNBLOGKED SHEAR WALLS ARE NOT PERMITTED. WHERE PANELS ARE APPLIED TO BOTH FAGE5 OF A WALL 4 NAIL SPACING 15 LE55 THAN b" O.G. PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMINO SHALL BE MIN. 3x Wf NAILS ON EAGH 51DE STAGGERED. SILL NAILING SHALL BE HALF THAT 5PEGIFIED IN THI5 5GHEDULE AND 5TAGGERED w/ MIN 3x SILL PL. (1), ALL 5TUD5 SHALL BE SPACED @ Ib" O.G. (2). ALL NAILS FOR PLYWOOD SHALL BE COMMON OR SHORT NAILS UNO. (3). ALL NAIL5 5HALL BE 5TA66ERED WHERE NAILS 5PAGED 2" O.G. (4). ALL FIELD NAILS TO BE IOd @ 12" O.G. (5). ALL LAG BOLTS SHALL HAVE 1-1/2" MIN. EMBEDMENT INTO SUPPORTING WOOD MEMBERS. (b). ALL 20d NAIL HOLES SHALL BE PREDRILLED. Fil TOP OF BEAM @ TOP OF JOISTS aTOP OF BEAM @ BOTTOM OF JOISTS F31 TOP OF 2x NAILER c) TOP OF JOISTS ETOP OF 2x NAILER @ BOTTOM OF JOISTS F5] BOTTOM OF BEAM @ BOTTOM OF GLG. 1015T5 BOTTOM OF BEAM @ TOF OF PLATE5 TOP OF BEAM @ TOP OF PLATE5 F&I TOP OF BEAM @ BOTTOM OF BEAM # DESIGNER: HUDGINS DESIGN 27587 PASEO SEGOVIA SAN JUAN CAPISTRANO, CA 92675 TEL: 949.322.7922 FAX: 949.488.8940 EMAIL: hudginsdesign@oox.net �at 16 s , 4 ,I PROPERTY OWNER: STEPHANY PANLILIO 23052-H Aida Pkwy. #611 Mission Viejo, CA. 92692 TEL: 949.37$.2100 PROJECT ADDRESS: 1226 S. SHELTON ST ZONE: R1 APN: 013-024-16 LEGAL DESCRIPTION: TR 557 LOT 91 SUBMITTAL SET REVISION DATE SUBMITTAL NO. 1 11 OCT 2005 SUBMITTAL NO.2 IIDATE: 10.06 05E0 DRAWN BY:aSQ�H.I 17540ST5 N.T.S. POST PER PLAN POST PER PLAN SIMPSON STAB BOLT OR 615 PER PLAN ,vMP5ON,, HP PER PLAN w/ 55TB BOLT SLAB PER PER SCHEDULE FOUNDATION PLAN I OF APPLICABLE) 2x SILL PLATE PAD PER FOUND. PLAN RE -BAR PER GONG. FOOTING PER PAD SCHEDULE FOUNDATION PLAN 55TD 5ELIEC110N TABLE MODEL 1-POUR 2-POUR MTT25 5611316 5ST520 HO 2A 55T516 5STB20 H05A 59TB20 95TB24 2X STUDS FEIZ , PLAN HP 6A 55TB26 SSTB34 K/ AB.S PER SHEAR 2 !/21 0 2 1/2.1 HD OA 5ST520 55T534 WALL HDIOA 6_t55TE04 rOW-f;MTr= 5LA13 PER FOUNDATION PLAN Y x x 4V R j �� 1 3/4" MIK, RE -BAR TOP 4130TT CONT. PER PLAN 1:4, 63 COW- FOOTING PER FOUNDATION PLAN PER sI AN PM PLAN NOTE: DEEPEN FTC? AS REQUIRED TO OBTAIN ANCHOR EMBEDMENT AND CONCRETE COVER 17 1$ HOLD-DOWN N N.T.5. 9 SIMPSON HOEDOWN 5 EXTERIOR FTG 111=11-all 1 www / STAB" BOLT a m j MIN. DBL STUDS 0 I END OF SHEAR PANEL 2X STUDS PER PLAN HD PER PLAN 1/2" EXPANSION JOINT i W AB.'5 PER SHEAR Iy KALL (E) SILL PLATE CONCRETE DRIVEWAY CONCRETE GARAGE SLAB CONCRETE SLAB PER (05V)PR WECOO5LA5 IT F15 FOUNDATION PLAN PER FOUNDATION SLAB EN .4,.-.g r FOUNDATION PLANPEP, a. 44 Hill HL., TIES 0 12' O.G. ; 2-#4 BARS CONT, a TOP 4 5TM. 5" EDGE DISTANCE Zc RE -BAR TOP 6 BOTT lij 511"IP50N SET EPDXYCONT. PER PLAN RR *252-tcl Cows. FOOTING PER FOUNDATION PLAN PER FLAN PLAX GRADE BEAM @ GARAGE I 11= 1 1-011 K m XZUR5 WHERE NEW 2X STUD 14A J_ � EXIST 2X 5TUV I,,L (E) 2X STUDS STUDS PER PLAN INTERIOR FINISH NEW GONG SLAB a FT& GARAGE FINISH P.T.D.F, SILL wl ANCHOR ED NU DOWELS 0 TOP 4 BOTT. 1ST GONGSLAB 4 FTC NEW SLAB PER EMBEDED W FOUNDATION PLAN BOLT PER FOUNDATION PLAN EXI5TINr;v CONCRETE -AD 3/6" EXPANSION JOINT E.N.XY I. &ARA6E SLAB PER TION PLAN W. FOUNDA CONCRETE SLAB PER x X_��x FOUNDATION PLAN Lu -#3 DOWELS 0 12" OjG. "A o 2 FOUR COLD JOINT X #4 BAR o 31-oll O.G. ........... a. EMBEDDED b" INTO E. FT5. w W 3/4"DIA. HOLES BY W LONG 0 c t PER MANUF SPEC - FILL Hl EPDXY EXTEND lb" INTO PEW SLAB. 7RQ. .............. r 1 1-10 1 MIN MIN. EPDXY EMBEDMENT M RLA# EXISTING GONG. FOOTING I;M-13AR TOP 4 BOTT AT EXISTING FT&. CONT. PER PLAN PROPOSED EX19TIN5 CONDITION FM PLAN NOTE: SPECIAL INSPECTION REQUIRED PER CDC SEC 1101 M§ E. FTG. TO N. FTG. CONN. 5/15'01A, X 12" AT 48" 0.6, MIN. AT SHEAR WALL SEE FON PLAN SHEAR HALL SCHEDULE FOR BOLT SIZES AND SPACING ANCHOR BOLT MAYBE REPLACED k1 "SIMPSON" ET22 SHEAR HALL PER PLAN 516" 05PACED TO MATCH SCH. ON FOUNDATION PLAN wl MIN. 6' EMBEDMENT INTO EXIST. FOOTING. INSTALL PER MANUFACTURERS SPECS. EXISTIN6 CONCRETE SLAB 1. W MIN. EP6E DISTANCE TO CENTER OF A, BOLT 7 EXISTING FOOTING 16 (N) ANCHOR BOLT TO (E) FDN. SCOOP FTG. TO (E) SLAB Dl PLYWOOD WHERE OCCURS E. 2x BLOCK- 4" CONC. SLAB Wl- 6*x6"-#10/#10 W.W.M. UNO 6 MIL. VISQUEEN 012" SAND BASE SHEET METAL TO - COVER E, WOOD #4 BAR @ 24" O_C_ EMBEDDED 8" INTO E, M. USE 3W' HOLES BY 7* LONG - FILL W/ EPDXY. a 5TUD5 PER PLAN GARAGE INT. FINISH E. 2x4 STUDS@ 16- O.C. EXTERIOR FINISH P.T.D.F. SILL K/ ANCHOR BOLT PER FOUNDATION PLAN &.1, METAL HELP SCREED A36S @ 16- O.C. 5/6"EXPANSION JOINT FINISH GRADE GARAGE SLAB PER E. SHEATING FOUNDATION PLAN T �1� > 15 MIN., X x E. FLR. JOISTS RE -BAR TOP 4 E30TT CONT. PER PLAN E. FOOTING FER PLAN • 12:'SCOOP FTG, TO (E) 8 RAISED fDN. m 2 SUBMITTAL NO. 1 11 OCT 2005 SUBMITTAL NO. 2 DETAILS SCALE: AS NOTED JOB NO: 05041 DATE: 10.06.05 DRAWN BY: S.H N117TH 5/8"MIN. EDGE DIST. Vil M -114 MAX BORE 60% OF WIDTH 2x4 - (2 1/8' DIA HOLE) 2x6 - (3 3/16" DIA. HOLE) 5/8" MIN, EDGE DIST. MAX NOTCH 40 % OF WIDTH _COKADtGr, stti Ca. TAN ER PLAN U- HANGER HANGER PER PLAN •I ;Im, I MrdA MAX BORE 40 % OF WIDTH 2x4 - (13/8' DIA. HOLE) 2x6 - (2 1/8" DIA HOLE) MAX BORE 60% OF WIDTH ON DBL. STUDS. NO MORE THAN 2 PER DBL. STUD 2x4 - (2 1/8' DIA HOLE) 2x6 - (3 3/16" DIA HOLE) MAX NOTCH 25% OF WIDTH 2x4 - (7/8' DEEP NOTCH) 2x6 - (13/8' DEEP NOTCH) STUD LEFT SHALL BE SOUND WOOD, & HAVE NO KNOTS, BREAKS, SPLITS, EXCESSIVE SLOPE OF GRAIN, ETC. EXT. OR BEARING WALL NOTCHM MIN. (b)-thd NA ILS TO J5T MIN. (I)-Ibd Al IGT TO PA (EACH 2x 5 1. Z ROOF RAFTERS PER PLANS 1 EDGE NAILING 4. SIMPSON MSTA24 5.4x BEAM PER STRUCT. PLANS 6. (3) 2X4 STUDS 7. DBL, TOP PLATES MIN, NAIL TO F (5AC JOISTS PER F WALL PER PL STS PER PLAN R1176E BEAM OR BOARD PER PLAN "SIMPSON" A35F AT EA 51VE OF P05T 4x KIN6 P05T PER PLAN 'SIMPSON" A35 AT EA SIDE OF POST STUD WALL MR PLAN DBL STUD BELOW K.P. HDR OR Be4AM KHEN OC6UP-5 PER PLAN AKING POST GONNEGTION AT 2X5TUP k4ALL ST:22 a 521, O.C. ROOF SHT6. MIN, (5)-Ibd NAILS AT JST TO RFTR PER PLAN :)N" OAN6eR5 E.N. NM PER PLAN SHEAR HA" PER PLANT > ST22 0 521, Or - ROOF 5HT&. PLY1,-V ROOF 51HT5 0/ RAFTERS PER PLAN E.N. "SIMPSON" A35 -a 32" O.C. x .r EON.. 'IMP, x 'SIMPSON" A35 SCHEDULE x _ :1 Pm SCHEDULE L. JSTS PER PLAN DBL. TOP PLATE 2x STUDS 0 161, O.C. 'SIMPSON" A35 SPAr-IN& a TOP PLATE, U.N.O. ON PLANS SHEAR WALL # PANEL ONE SIDE PANEL TWO SIDES NONE 32" O.C. q 20" Q.G. 10.51, O.G. 10 14 OZ iZ;' Or- 5.51, O.G. 12 a, O.G. 4.5" O.C. MR PLAN ARD MR PLAN L_J 5 SHEAR TRANSFER @ SAVE RIDGE BEAM OR BOARD PER PLAN "5IMP50N" A�15P AT EA SIDE OF POST 4x KIN& P05T PM PLAN 'SIMPSON" A55 AT EA SIDE OF POST DEL. C.J. OR BEAM KHIFN OCCURS PER PLAN BKINO POST 6ONNEGTION AT 2X CEILINO JOIST N.T.5 P ROOF 544T6 ol ER5 PER PLAN 2X NAILER W (2) EVERY E. RAFTER bd 0 EA. SIDE Ibd TOE -NAIL. 2x4 - (113/8' DEEP NOTCH) 2x6 - (2 1/8' DEEP NOTCH) INTERIOR FINISH E. ROOF RAFTERS W. NON -BEARING PLYkO ROOF 5HT6 of RAFTERS PER PLAN!�ttm "SIMPSON" A35 PER 'SIMPSON' A35 561HEOULE PER SCHEDULE EN VEIL. TOP PLATE SHEAR HALL PER PLAN 2x STUDS a 16" O.C. 2x STUDS Q Ib* O.G. SHEAR K64-L PER PLAN E.N..N. 2x BILOOK E.N. 'SIMPSON' A35 PER SCHEDULE rACEILIN6 JOISTS E.N. PER PLAN DBL. TOP PLATE 2x 971.105 0 16" O.C. SHEAR WALL PER PLAN 'SIMPSON" A55 SPACIN6 a TOP PLATE, U.N.O. ON PLANS SHEAR, WALL # PANEL ONE SIDE PANEL TWO SIDES NONE 32' O.C. — Of 201, O.C. 103'. O.G. 10 14" O.G. 1.01IO/S. 11 11110.0. 55* O.C. 1,O.. O.G.45 O.G.O. O.G. 14 6" O.C. — SHEAR TRANSFER 6 RAFTERS PER PLAN PLYHO ROOF, SHTe 0/ 'SIMPSON" A55 5PAclN6 a TOP PLATE, U.N.O. ON PLANS SHEAR HALL# PAWL ONE SIDE PANEL THO SIDES NONE 52" O.C. — cl 2010.6. 1051, O.C. 10 14" O.G. O.G. i.o* o.. I 11 11"O.C. 53110.6. 12 -1-wac, 45' O.G. 15 11,10.0. 14 1 6" O.C. A35 PER 5c+wULE N E.N. 05L. TOP PLATE NEH CRIPPLE WALL 2x5TUI?9 @ 1611 O.G. SHEAR HALL PER PLAN NEH CRIPPLE HALL 2x STUDS 0 16" O.C. E. CEILING JOISTS PER PLAN SHEAR HALL PER PLAN CONTINUOUS TO RAFTER CEILIN& JOISTS F E.N. PM PLAN tEK ABOVE Z N. it 4 EXISTINC, BEL& E N, i 05L. TOP PLATE EXISTING STUDS 0 16" O.G. ALL M J 11<_, 5HEAIZ WALL MR PLAN WALL NOTCHNG i0l I of a, PROJECT INFORMATION CALIFORON01A PROPERTY OWNER- STEPHANY PANLILIO 230524iAlida P"., $ffil 1 ALLNOT' N75 19 TITLE N.T.5. 01TT■ PATION N.T.S. 11 7 SHEAR TRANSFER Mission Viejo, CA. 92692 TEL949.378,2100wvv FRAMING' PROJECT ADDRESS: 1226 S. SHELTON ST. ZONE: Rl CONT. 2X NAILER IAV (2) 2x CRIPPLES a fro" OZ. Ibd a EVERY E. RAFTER 4 (1) 16d @ F-A. 54DE 2X FURLIN - SAME SIZE AS N/ (1) Ibd TOE -NAIL. RAFTERS PER PLAN APN: 013-024-16 LEGAL DESCRIPTION: TR 557 LOT 91 2x SOLID BLOCKING (EXCEPT WHERE ENDS OF JOISTS RAFTER - (2) I&I's MIN, 2X BLOrKN6 ARE NAILED TO A HEADER AND/OR RIM JOIST OR TO E. PLYJ�V ROOF SHTi9 E.N. Z----_PLyp0 ROOF 5HTC7 0/ SUBMITTAL SET N 2X4 a 4'-0" O.C. W REVISION DATE AN ADJOINING STUD OR BY OTHER APPROVED MEANS). 0 (4) 16d's MIN. IN tilt E.N. SUBMITTAL NO. 1 11 OCT 2005 DBL. TOP PLATE "SIMPSON' SUBMITTAL NO. 2 0 HEADER + A35 PER A55 EACH END tXMl A ll z 0 0 N "5iMP5ON" ST62224 a EACH + CORNER OF OPENING — + 0 f::G4 0 11111 1 Z KIN6 STUD TRIMMER N, "-- 45MIN. 2X R106E BEAM CONTINIUOUS 2x VSa 61 Oz No BREAK a cLe. 10 co m X SOLID OLOGK 0 FIRST STUD GAY 0 25 2S 2xER ROOF RAFTERS P PLAN HATCHING INDICATESSTRUCT. SHEAR WALL PER PLAN (3) 16&9 -ONE TOE -MAIL MIN. ONE EACH SIDE 4x R.O. SILL P5L. TOP PLATES NOTCHES NOT PERMITTED INTERIOR BEARING HALL NOTCHES WITHIN 1/2 WITHIN MIDDLE 113 SPAN BUT BORED HOLES ARE BORED HOLES ALSO CIL& JSTS. PER PLAN PER STRUCT. PLAN "SIMPSON" A35 SPACIN& a TOP PLATE, U.N.O. ON PLANS SHEAR KALL # PANEL ONE SIDE PANEL Tk4O SIDES WO -NE 5 �2 O.G. a20" O.C. 10 5' O.G. 10 14- O.C. 70- O.G. it II" O.G. 5.5. O.G. 12 a"OG. 45" O.G. 15 14 6-O.G. ri I CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 1 of 5) CF-IR Project Title q Date Building Permit 4 Project Ad lie-lu <; Documentation Au ' 1 Telephone lin- 7 11 - Compliance Method (Prescriptive) Climate Zone Qi Plan Check /Date Field Check / Date Enforcement Agen Alternative Component Package Method: (check one) _C XD ___D (Alternative) Package C and Package D choices require HERS rater field verification and/or diagnostic testing (see CFAR page 3) For Package DAlternative see Appendix B Table 151-CFootnotes 7-14 GENERAL INFORMATION Total Conditioned Floor Area (CFA) A—fe Average Ceiling Height: ft Maximum Allowed West Facing Fenestration Products Per Table 151-B or 151-C ---- (5% X CFA) ft2 Maximum Allowed Total Fenestration Products Per Table 151 -B or 15 1 -C ---- (20% X CFA) _ 100 ft2 ✓ IJ Building Type: (check one or more) Single Family Multifamily Addition Alteration 0 (If adding fenestration fill out WS-4R, Fenestration Maximum Allowed Area Worksheet and see Section 8.3.2 for Additions and 8,33 for Alterations.) Number of Stories: Number of Dwelling Units: Floor Construction Type: Sla ised Floor (circle one or both) Front Orientation: North 1 South West / All Orientations (input front orientation in degrees from True North and circle one). G> V/ X RADIANT BARRIER frequired in climate zones 2, 4, 8-15) OPAQUE SURFACES INCLUDING OPAQUE DOORS Component Type (Wall, Roof, Floor, Stab Edge, Doors) Frame Type (Wood or Metal) Cavity Insulation R-Value Continuous Insulation R-Value Assembly U- factor (for wood, metal frame and mass assemblies) Joint Appendix IV Reference Roof Radiant Barrier Installed Yes or Na Location Comments (attic, garage, typical, etc.) wvt— ts), 1) See Joint Appendix IV in Section IV.2, IV.3 and IVA, which is the basis tbr the U-iActor criterion, U-factors can not exceed prescriptive value to show equivalence to R-values. Residential Compliance Forms April 2005 CERTIFICATE OF C0MPL1A_N_CE* RESIDENTIAL (Page 2 of 5) CF-IR Proct Title L Dalet g FENESTRATION PRODUCTS - U-FACTOR AND SHGC V 0 FENESTRATION MAXIMUM ALLOWED AREA WORKSHEET WS-4R -must be included for New Construction, Additions and Alterations, Fenestration #/Type/Pos. Orien- Exterior (Front, Left, tation, Shading/Overhan.. Rear, Right, N, S, E, Area U-factor SHGC V box if WS-3R is Skylight) W1 U-factor 2 Sources SHGC4 Sources included 13 0 0 Pk NEAf L 0. %4c� 13 _- 0 FA _40— 11 i I i 0 1) Skylights are now included in West -facing fenestration area if the skylights are tilted to the west or tilted in any direction when the pitch is less than 1: 12. See § 15 1 (f)3C and in Section 3.2.3 of the Residential Manual 2) Enter values in this column are either NFRC Rated value or from Standards default Table 11 6A, 3) Indicate source either from NFRC or Table 116A, 4) Enter values in this column from NFRC or from Standards Default Table 11 6B or adjusted SHGC from WS-3R. 5) Indicate source either from NFRC or Table I I 6B 6) Shading Devices are defined in Table 3-3 in the Residential Manual and see WS-3R to calculate Exterior Shading devices. 7) See Section 3.2.4 in the Residential Manual. HVAC SYSTEMS Heating Equipment Type and Capacity (furnace, heat purnp. boiler, et�.L Minimum Efficiency (AFUE, or 1`1S7 ') Distribution Type and Location (ducts, attic, etc.) Duct or Piping R-Value Thermostat Type Configuration (isL)Ilt or p Cooling Equipment Type and Capacity (A/C, heat pump, evap. coolin�) Minimum Efficiency (SEER or EER) Duct Location Duct R-Value Thermostat Type Configuration (split Residential Compliance Forms CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 5 of 5) CF-IR Project Titl Date Wo COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts I and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that cony fiance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Desiener or Owner (per Biis�aess and Profeipf4pna Code) Documentation Author Name- Name: S> eoq- Title/Firm7 Title/Firm: Address: _7 � P JIS 5b Address: 2_755 CA 6176 -7 �,-* -TI/A CAP'040­0 Telephone: Telephone: L *7 Itt 6?1 U&I License (signature) (date) (signature) (date) Enforcement Agency ralephone:,:l / 1 N4 Residential Compliance Forms 7 ?i;t�10 April 2005 April 2005 SEALED DUCTS and TXVs for Alternative Measures) A signed CF-4R Forin must be provided to the building department for each home for which the following. are re wired. Sealed Ducts (all climate zones) (Installer testing and certification and HERS rater field verification required.) ❑ TXVs, readily accessible (climate zones 2 and 8-15 only) {Installer testing and certification and HERS Rater field verification r�uired.) El Refrigerant Charge (climate zones 2 and 8-15 only) (installer testing and certification and HERS Rater field verification required.) OR ❑ Features Alternative to Sealed Ducts and Refrigerant Charge /TxVs (See Package D Alternative Package Features for, L Project Climate Zone in the RM Appendix B Table 15 1 -C, Footnotes 7-14. OR For additions and alterations, duct systems that are not documented to have been previously ❑ seated as confirmed through field verification and diagnostic testing in accordance with procedures in the Residential ACM Manual and duct systems with more than 40 linear feet in unconditioned __.spaces shall meet the requirements of Section 150(m) and duct insulation requirements of Package D. WATER HEATING SYSTEMS Check box if system meets criteria of a"Standard" system. Standard system is one gas -fired water heater per 0 dwelling unit. If the water heater is a storage type, 50 gallons is the maximum capacity and recirculation system is not allowed. El Check box when using Preapproved Alternative Water Heating table, 'Fable 5-4 in Chapter 5 in the Residential Manual. No water heating calculations are required, and the system coLnplies automatically, Check box if system does not meet criteria of "Standard" system, and does not comply with the Preapproved 0 Alternative Water Heating table. In this case, the Performance Method must be used and must be included in the submittal. — 0 Check box to verify that a time control is required for a recirculating system pump for a system serving multiple units Svstems serving single dwelling units; Water Heater ape/Fuel Ty2e Distribution Type Number in System Rated Inputs (kW or Btu/hr) Tank Capacity LaaikmE) Energy Factor' or Thermal Efficiency Standby' °fo)- —Tank External Insulation 1 I R-Value _Loss System serving multiple dwelling units Water Heater Distribution Type Number in System Rated Inputs (kw or Btu/hr) Tank -y Capacity (gallons) Energy Factor' or Thermal Efficiency Standby' Loss (%) Tank 1 External Insulation R-Value -4 SPECIAL FEATURES NOT REQUIRING HERS VERIFICATION (add extra sheets if necessary) Indicate which special features are part of this project. The list below only represents special features relevant to the nreqn.iintive rnethod V Feature Required Forms if a iicable Description 0 Metal Framed Walls CF-IR Radiant Barriers CF-IR 0 Exterior Shades WS-4R 0 Coot Roof N/A; Attach C RRC Label to Forms, D ITedic led Hydronic Heating - Perfolmance Calculation System Required- Attach Run to Fornns. 0 Combined Hydronic System Performance Calculation Required; Attach Run to Forins. Cl Gas Cooling Performance Calculation Required. 0 Buried Ducts N/A; Indicate on building plans. 0 Kitchen Pipe Insulation See Section 5.6,2 Distribution Systems in Residential Manual. Multiple Water Heaters Per See Table 5-13 or use 0 Performance Calculation and Dwelling Unit attach Run to Forms. 0 Central Water Heating System Performance Calculation and Serving Multiple Dwellings attach Run to Forms. 0 Non-NAECA Large Water CF-IR Heater See Table 5-13 or use 0 Indirect Water Heater Performance Calculation and attach Run to Forms See Table 5-13 or use 0 Instantaneous Gas Water Heater Performance Calculation and attach Run to Forms See Table 5-13 or use 13 Solar Water Heating System Perfortnatice Calculation and attach Run to Forms 0 Wood Stove Boiler Performance Calculation and attach Run to Forins SPECIAL FEATURES REQUIRING HERS RATER VERIFICATION inciri Pytrn Qkpptc if npri-cQqr%f) Inciii-ptp to the H F R q Rater xvh;r­,h rr,-rlitz ,m- mart of this nrnippt nnri nppri vprifirntinn ✓ Feature Required Forms (if applicable) Description _4 Duct Scaling CF-6R part 4 of 12 ❑ Refrigerant Charge CF-6R part 5 of 12 ❑ static Expansion Valve CF-6R art 6 of 12 1) For small gas storage water heaters (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance, and heat pump water heaters, list Energy Factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency, Thermal Efficiency and Standby Loss, For instantaneous gas water heaters, list Rated Input and The . ri-nal Efficiencies, Pipe Insulation (kitchen lines >_ 3/4 inches) All hot water pipes from the heating source to the kitchen fixtures that are '/4 inches or greater in diameter shall be thermally insulated as specified by Section 150 0) 2 A or 150 0) 2 B. Residential Compliance Forms Residential Compliance Forms April 2005 MANDATORY MEASURES SUMMARY: RESIDENTIAL (Page I of 2) MF-IR Project le Date Note: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*) below, When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minurUrn component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or check NA if not applicable. DESCRIPTION INA Designer_ Enforce -meet Building Envelope Measures: V § 150(a): Minimum R- 19 in wood frame ceiling insulation or equivalent U-factor in metal frame ceiling. ❑ F1 150(b): Loose fill insulation manufacturer's labeled R-Value: 13 171 § 15 0(c): Minimurn R- 13 wal I insulation in wood framcd �x a lis or equivalent U - G)cor in metal `rarile wo [is (does not apply exterior mass wallsL. § I 50(d): Minimum R- 13 1 aised floor insulation in flamed floor, n equi ualent t'- [ricror. § 150(c); Installation of Fireplaces, Decorative Gas Appliance's and Gas Logs. I. Masonry and factory -built fireplaces have: a a. closeable metal or glass door covering the entire opening of firebox I - 0 13 n — b. outside air intake with damper and control, flue damper and control GR 0 11 1 No continuous burning gas pilot lights allowed, § I 50(f): Air retarding wrap installed to comply with § 151 meets requirements specified in the ACM Residential Manual, AT❑13 1 § I 50(g): Vapor barriers mandatory in Climate Zones 14 and 16 only, ❑ 0 § 150(i) : Slab edge insulation - water absorption rate for the insulation material alone without facings no greater than 0.3%, water vapor Permeanue rate no greater than 2.4Terrnhnch. ❑ 171 § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include CF-611 Form: 0 [1 § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls, 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage, 0 2. Fenestration products (except field -fabricated) have label with certified U-factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification, ❑ 11 3. Exterior doors and windows weritherstripped, all joints and penetrations caulked and sealed. ❑ 13 Space Conditioning, Water Heating and Plumbing System Measures: 110-§ 113: FIVAC'equipment, water heaters, showerheads and faucets certificd b} the Fne;gy Commission. § 150(1t): Heading and/or cooling loads calculated in accordance with ASH RAL, S"A.ACor ACCA. 11 El ElNA § Setback thermostat on all applicable heating and/or cooling systems. 150(i): S 0 § 1500): Water system pipe and tank insulation and cooling systems line insulation. 0 El 11 1. Storage gas water heaters rated with an Energy Factor less than 0,58 must be externally wrapped with insulation having an installed thermal resistance of R- 12 or greater. i� 0 11 1 Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R- 16 internal insulation and indicated on (lie exterior of the tank 8110��-Vahle, 0 El 3. The following piping is insulated according to Table I 50-AIH or Ftluation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest it) water heater tank, non -recirculating SYSIC111S, and entire Icngth of recirculating sections of hot water pipes shall be insulated to I -able 150B. — 0 0 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. El I 0 4. Stearn hydrome heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑I o Residential Compliance Forms April 2005 April 2005 MANDATORY MEASURES SUMMARY: RESIDENTIAL (Page 2 of 2) MF-IR Space Conditionine, Water Heating and Plumbing System Measures. (continued) Enforce, NAV' Designer ment 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. 0 ❑6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in 0 conditioned space. 1. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation, 11 0 I 50(m): Ducts and Fans 1. All ducts and plenums installed, sealed insulated to meet the requirement of the Civic Sections 601. 602,603,604,605 and Standard 6-5: supply -air and return -air ducts and plenums are insulated to a minimum installed level of'R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable 11 me El requirements of U L 18 1 : UL 181 A, or UL 1813 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seat openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and 13 El support platforms may contain ducts. Ducts, installed in cavities and support platforms shall not be compressed to cause 0-1% reductions in the cross -sectional area of the ducts, 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes F-1 "o unless such tape is used in combination with mastic and draw hands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated Sal dampers. 6. Protection of Insulation. insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradition of the material, 7, Flexible ducts cannot have porous inner cores. ad 0 ❑ 114: Pool and Spa Heating Systems and Equipment. T I.Athermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the 19 171 0 heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2, System is installed with: it, at least 36" of pipe between filter and heater for future solar heating 15 1:1 b. cover for outdoor pools or outdoor spas n 11 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired fart -type central furnaces, pool heaters, spa heaters or household cooking appliances have 110 C0116171UOUSIV pr in 0 burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) burning § I 18(i): Cool Roof material meets specified criteria 171 ❑ Residential Lighting Measures: §1 50(k)l-, HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts or greater are electronic and have an output frequency no less than 20 kHz § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 171 ❑ I 50-C, luminaire has factory installed HID ballast § I 50(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in § 130 (c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy M K ❑ luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. 1 50(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms utility rooms shall be high efficacy J -e controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on luminaires. OR at 1771 automatically or have an always on option, 1 50(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70fti): OR are controlled by a dimmer switch OR are ❑ 'D controlled by an occupant sensor that complies with Section 11 9(d) that does not turn on automatically or have an always ono tion. § I 50(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are. certified airtight to ASTM E283 and labeled as air tiht (AT) to less than 2.0 CFM at 75 Pascals, § I 50(k)6: Luminaires providing outdoor lighting and Permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other 171 Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section § I 50(k)7: Lighting for parking lots for 8 or more vehicles shall have lightim-, that complies with See. t 30, 132, and 147, V ❑ Li>htiri� for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146. _. § 1 50(k)8; Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with %Zpq 0 11 Section 119(d). Residential Compliance Forms April 2005 Iff 27587 PASEO SEGOVIA SAN JUAN CAPISTRANO, CA 92675 TEL: 949.322.7922 FAX: 949.488.8940 EMAIL: hudginsdesign@cox.net PROPERTY OWNER, STEPHANY PANLILIO 2305241 Afide Pkwy., #611 Mission Viejo, CA. 92692 TEL: 949.378.2100 PROJECT ADDRESS: 1226 S. SHELTON ST. ZONE: RI APN: 013-024-16 LEGAL DESCRIPTION: TR 557 LOT 91 SUBMITTAL SET REVISION DATE SUBMITTAL NO. 1 11 OCT 2005 SUBMITTAL NO. 2 SCALE: AS NOTED JOB NO: 05041 DATE: 10.06.05 DRAWN BY. S.H.