Loading...
HomeMy WebLinkAbout10150671.pdf4 I 4 I SUMO RESTAURANT 1500 MACARTHUR BLVD, El 07 F2_1 F 771 041 MEDICAL / DENTAL BLDG. 3620 S. BRISTOL ST. 79_1 HIM111111 PT_PT_PKT_ BALLY TOTAL FITNESS 3701 S. PLAZA DRIVE IN in NJ I hi I PM,40M 21.361 ACRES Li F111 3" S. B"T(X ST %3W = H. M23 li M. o I M2 ff I I I I VONS MARKET 3650 S. BRISTOL ST. IK t CASUALMALE am$ , ERWOL ST, PARCEL2 F12 PM.8,4W6 21.361 ACRES spur PT -PT HM22 ANDCAP VA AOMMMLE F2_1 rl i ii i i i i i i i i i i i i i i i i i I I n BANK OF AMERICA a 4 -� 3730 S. BRISTOL ST. JACK W A BOX 371 STOL ST- =T, AP-PRC)VED 4'UN PLANNING DIVISH Passanger Unloading Zone Stripes @36" on center _19e70 Square inch accessability sign @ 80 above grade per Section 112913.5 d IT'Wide x 6" High x 4'-0" Long Concrete tire stop anchor 7din one gZ center into concrete slab ------ -------------- Wheel Stop - ----- yp, Reflectorized sign not less than 70 sq. inches consisting of a profile view of a wheelchair with nr-ri i ant in white on n fivkrk- hi"im back round Sign shall be posted at a minimun height of A 4 K 80" from the bottom of the sign to the parking space finished grade. 40 R J-_ CALLENS COMMON MACARTHUR BLVD. ■ SITEENk ............... .......... N i 2nd story I Open Mot A 2nd story breezway Court yard 1 breemay ........ .. .. ... ­pade­, ........... .................................. % .. ........ MEDICAL I DENTAL BLDG. 3620 S. BRISTOL ST. Site Plan 1st Floor SCALE: N.T.S. Em Profile view of a wheelchair with occupant in white on blue background. The profile view shall be located so that it is visable to a traffic enforcement officer when a vehicle is properly parked in the space and shall measure 36' x 36of . Maximum slope of surrounding areas shall not exceed 2%. Per Section 112913.5 mmo ra 12" tall 7!rwh7fte lettering 5.-0"-4 llumm#:�# W-MMATOWIflq.,11"licai SCALE: N.T.S. 1. Provide 5 x5 handicap decal or plastic sign posted on door or side light centered 60 above entry landing. 2. The length of floor or landing shall extend 60 in the direction of door swing and 44 opposite the direction of door swing. 3. Threshold shall be not more than 1/2 high beveled at 2 horizontal to 1 vertical to a vertical maximum Y4" 4. Minimum door size is 36 with a clear opening of 32" with door in 90 degree open position. 5. Width of landing shall extend 24" on strike edge of exterior doors and 18" for interior doors. 6. Door handles shall be lever type, push / pull or equivalent. Maximum effort to operate doors shall not exceed 8-1/2 lbs. for exti`rior doors and 5 lbs for interior doors. 7. The required path of travel leading from the disabled parking spaces to the area of remodel shall measure a min. width of 48 & possess a cross slope not to exceed a max. of 1/4" per foot (2.038% gradient). 8. If cars overhang the path of travel, than the walkway shall be 7' Min. wide to accomodate a dear 4' path 9. The top landing area for a curb -cut ramp shall measure minimum dimensions of 48" x 48" & shall possess a max. cross slope not to exceed 1/4" per foot (2.083% gradient) in any direction. 10. The rimary entrance to the building shall display a sign/decal measuring 5 x 5 and be displayed at a min. heigft of 60 as measured from the ground to the center of the sign/decal on the latch or right side of the door. 11. Disabled parking spaces, path of travel & access shall not be blocked modifies or eliminated during construction. Any and all temporary accomodations must be approved by the building division 12. Toilet partitions for the accessible toliet shall be provided with a latch that does not require grasp or twisting & a u-shape or loop immediatly below the latch on the inside & outside of the partition door. 13. Toilet room floor shall have non absorbent material, which extends upward onto the walls at least five inches. 1 14. An additional sign shall also be posted in a conspicuous place at each entrance to offsite parking facilities, or immediately adjacent to and visible from each stall or space. The sign shall not be less than 17 inches by 22 inches in size with lettering not less than one inch in height, with clearly and conspicuously states the following: "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owners expense. Towed vehicles may be reclaimed by telephoning the Santa Ana Police Department at (714) 245-8665. CVC 22658a. 1. Storage, dispensing, or use of any flammable or combustible liquids, flammable gases, and hazardous chemicals shall comply with uniform Fire Code requirements. 2. Interior wall and ceiling finishes shall not exceed point flame spread of 200. 3. Interior wall and ceiling finishes in exit corridors shall not exceed Td point flame spread of 75. -2-a rating within a 75 foot travel distance to any point of the 4. Provide a portable fire extinguisher of not less than - building on. each floor and within any individual tenant space. Provide additional fire extinguishers as required by the governing fire department inspector. Travel distance is 30 feet in areas having flammable liquids. 5. Provide a portable fire extinguisher of not less than 10-bc rating at lunchroom facilities. 6 Every exit door shall be operable from the inside without the use of a key or any special knowledge or effort 7. A continuous minimum egress width of 44 dear shall be maintained thought the exit path of travel to the public way 8. Provide sign: "This door shall remain unlocked during business hours" to be posted above main entry door Fire Protection Notes I.vigriptl # on of work: j Tenant improvement: Ww Dental office space, scope of work Includes new Interior officesi suspended & Gyp. ceilings, plumbing, mechanical & electrical systems. J J J Building Codes California Building Code, 2W Edition California Mechanical Code s 2001 Edition Ca Ifornia Plumbing Code, 2001 Edition California Electrical Code, 2001 Edition Fitzpatrick Dental Desigi 5435 Atlantis Ct. Moorpark, Ca. (805)532-1870 4 III m 0i MM I i i to t, 4-A The tenants responsibility shall be limited to the tenant improvemerif J space only and the specific information as described within these A attached construction drawings. 4A & The designer(s)and/or the tenant shall not be held responsible for is 9 1 building systems and/or conditions provided to the tenants space others All existinj systems and services provided to the tenants leased space must mee with all governing agencies codes, specifications and requirements. N u mber of employees not to exceed1pu r- (4) X, 11!:31111 q4s ACCF551BLE PARKING 1. One accessible van parking Space Shall be provided. At least and the remaining shall be standard acce551b1e parking spaces The parking 5pace5 shall be placed 5o a disabled person will not go behind a vehicle other than their own. 3. The acce551ble parkingg 5pace5 dimen5ion5, Striping and 51gnage Shall comply with Section 11298.4. I. 5. When an acce551ble parking space 15 5tanding alone, the acce55 15le Shall be on the pa55enger5 50e. G. The required path of travel leading from the disabled parking 5pace5 to the area of remodel Shall measure a minimum width of forty-eight Inches (48") and p055e55 a cr055 slope not to exceed a maximum of one -quarter of an inch (1 /4") per foot (2.083% gradient). If cars overhang over the path of travel, then the walkway Shall be 7' mm, wide to accommodate a clear 4' path. 7. Built-up ram 5 are not allowed. Install curb -cut type ramps to comply with Title 24, bection 1 1 275.5. 8. The top landing area for a curb -cut ramp Shall measure minimum dimen5ion5 of forty-eight inches by forty-eight inches (48" x 48") and shall p055e55 a maximum cr055 Slope not to exceed one -quarter of an inch (114") per foot (2.083% gradient) in any direction. 23. Each lot or parking Structure where parking 15 provided for the public a5 client5, guest or employees, Shall provide acce551b1e parking a5 required by CBC Section 11295, 24. The words NO PARKING Shall be painted on the ground within each loading and unloading acce55 a151e. Th15 notice Shall be painted in white letters no 1e55 than 12 inches high and located 50 that it 15 v151ble to traffic enforcement of lClal5. See Figure 1 18-18A. CBC Section I 1 298.4, PARKING 51GNAGE 25. Provide parking Space identification in accordance with CBC Section 11295.5 including: a An additional 51gn Shall also be posted in a con5plcuou5 place at each entrance to off -Street parking facilities, or immediately adjacent to and v151b1e from each Stall or Space. The Sign Shall not be le55 than 17 inches by 22 inche5 in Size with lettering not 1e55 than one inch in height, with clearly and con5plcuou51y 5tate5 the following: "Unauthorized vehlcle5 parked in de5icjnated acce551ble 5pace5 not dl5playing dl5tingul5hing placards or license plates 155ued for per5on5 with d15abIlltie5 may be towed away at owner's expense. Towed vehlcle5 may be reclaimed by telephoning the Santa Ana Police Department at (7 14) 245-8GG5. CVC 22G58a." 2. The words 'NO PARKING' Shall be painted on the pavement within the loading and unloadingj unloading acce55 aisle. The notice shall be painted in white letters not 1e5 than 1 2" hlgh * vl5able letters no leas than 12 inche5 high and located 50 that It 15 vi5ible to traffic enforcement officials, 4. A reflectorized 51cjn a5 5pecified per CBC 1 1 295.5 Shall identify each acce55ible parking Space. 10. The primary entrance to the building Shall display a Sign/decal measuring a minimum of five inche5 by five inches (5" x 5") and be dl5played at a minimum height of (GO") a5 mea5ured from the ground to the center of the sign%decal on the latch or right 51de of the door. DOORS 12. Door handles Shall be lever type, push/pull or equivalent. Maximum effort to operate doors Shall be exceed 5 1125 per CBC I i 33B.2.5. 13. Threshold Shall be not more than 112" high beveled at 2 horizontal to I vertical to a vertical maximum of 1 /4". 19. Regardle55 of the occupant load, there Shall be a floor or landing on each 51de of a door. The floor or landing 5hail be not more than x-inch lower than the threshold of the doorway. Change in level between 74-inch and «-inch Shall be beveled with a 51ope no greater than 1 :2. Change in level cjreater than o-inch Shall be accompl15hed by means of a ramp. Provide detailed 5ection5 and plan vlew5 Showing compliance at all doorways requiring acce55112111ty. CBC 5ection5 1003.3. 1 . G, 1003.3. 1 . G. I ,1 1335. 2.4 and 1 1335. 2.4. 1 . 20. Doorway5 require dimensioning on the pian5 to insure compliance with the required landing area/maneuvering clearances at doors in accordance with CBC Section 1 1335.2.4.2 and CBC Figures I I B-2GA and i I B-2G8. 21 . "Maximum effort to operate doors Shall not exceed 5 pound5 for exterior doors and interior doors, Such pull or push effort being applied at right angles to hinged doors and at the center plane of Sliding or folding doors. Compensating devices or automatic door operators may be utilized to meet the above 5tandard5. When fire doors are required, the maximum effort to operate the door may be increased to the minimum allowable by the appropriate administrative authority, not to exceed 15 pound5. CBC Section 1 1335.2.5." FLOORING 17. "The Surface of floors Shall be Slip re515tant: When tested in accordance with ASTM C 10288 Test procedure for coefficient Coefficient of Friction, file must achieve a wet and dry value of not 1e55 than O.GO. Prior to the installation of the floor covering, a written statement from the flooring manufacturer must be 5ubmltted to the Dept. of Building * Safety Stating that the product to be installed meets current industry 5tandard5 for slip re515tance Providete5t information or 5ample5 of the flooring. 18. If carpet or carpet file 15 u5ed on a around or floor surface, then it Shall be securely attached; have a firm cushion, pad or backing or no cushion or pad; and have a level loop, textured loop; level -cut pile, or level-cut/uncut pile texture. The maximum pile height shall be 112 inch. Exposed edges of carpet Shall be fastened to floor 5urface5 and have trim along the entire length of the exposed edge. Carpet edge trim Shall comply with the requirements for changes in level. CBC Section I 1 245.3, WALKWAYS AND RAMPS 18. The ramp Shall p055e55 a d irectional Slope not to exceed a maximum of one inch (I ") per foot (8.33% gradient) and a cr055 slope of one -quarter of an inch (I /4") per foot (2.083% gradient). 19. Land rails Shall be continuous for the full length of the ramp. The handrall5 Shall be between 34"-38" a5 measured from the ramp Surface to the top of the rails, and extend at least twelve inches (1 2") beyond the top and bottom of the ramp. All handra115 Shall be returned. T1-1E EXTENSIONS SHALL EXTEND A FULL 1 2" PRIOR TO BEING RETURNED. The grip portion of the handrails 5hail not be 1e55 than one and one-cluarter inches (1-114") nor more than one and one-half inches (1-112") thick. The distance between the finished wall Surface and the edge of the handrail Shall be 1-1 /2". 20. If a walkway 15 used, the 51ope in the direction of travel Shall not exceed 1 :20 gradient (5.0%) cr055 51ope Shall not exceed 1 :50 gradient (2.0%), with a minimum width of forty eight inches (45"). 21 . Ramps Shall be provided with an intermediate landing every 30" in rise. The intermediate landing shall measure GO" on the downward direction of travel. 22. Top landings shall measure GO" long by the width of the ramp. Bottom landings Shall measure 72" long by the width of the ramp. 14. Walks and sidewalks Shall have a continuous common Surface, not interrupted by 5top5 or abrupt changes in level. 5urface5 Shall be 511p re5i5tant. Refer to CBC 5ection5 1 1245 and 1 1335.7 for additional requirements including maximum slopes (cr055 slopes and along the path of travel) allowed, grading and level areas. 15. Any obstruction that overhangs a pede5trian'5 way Shall be a minimum of 80 Inches above the walking Surface a5 mea5ured from the bottom of the obstruction. CBC Section 1 1335.8.2. I G. Walk5, 51dewalk5, and pedestrian ways Shall be free of cjratng5 whenever p0551121e. For gratings located in the Surface of any of these areas, grid openings in gratings Shall be limited to Y2 inch in the direction of traffic flow. CDC Section 1 1335.7.2 17. Curb ramps Shall comply with CBC Section 1 1275.5. A level landing 4 feet deep Shall be provided at the upper end of each curb ramp over its full width to permit Safe egre55 from the ramp Surface, or the Slope of the fanned or flared 51de5 of the curb ramp shall not exceed I unit vertical to 12 unit5 horizontal (8.33% 510pe). CBC Section 1 1275.5. Item 4. 14. Sanitary facilities are required to provide two Separate types of 5l6Jna6Je; one type located on the doorway to the facility, and another type mounted on the wall adjacent to the latch Side of the door. Slgnage to be a5 5pecified in Title 24, Section I 115B.5and I 1 17.5.5. 15. The operating part of all acce55orie5 Shall be installed at 40" maximum to the centerline of the operating part from finished floor Surface. I G, The water closet Shall have an elongated bowl type. The top of the acce551ble toilet seat 5hali be 1 7""-1 9' above finished floor, the water closet Shall be located 18" from the centerline of the bowl to the finished surface of the adjacent wall. The clear d15tance of the water closet to the other 51de Shall be 42" from the centerline of the toilet to the finl5hed Surface (ADA), or 32" from the edge of the bowl. ACCE5515LF ROUTES OF TRAVEL 13. Entrance(5) to the building or facility and the primary path of travel to the 5peclfIC area of new work, alteration, Structural repair or addition Shall be acce551191e. Path of travel incorporated all elements from the exterior arrival 5lte to the remodeled area. Section I 114B. 1 .land I 1 145. 1 .3. a. "All enclosed portions of buiiding5 customarily occupied by human bein6j5 Shall be provided with a mechanically operated ventilation System. Such mechanically operated ventilation 5y5tem Shall be capable of Supplying a minimum of 15 cubic feet per minute of out5lde air per occupant during Such time a5 the building 15 occupied. If the velocity of air at a reg15ter exceeds 10 feet per Second, the rerjl5ter Shall be placed more than 8 feet above the floor directly beneath. CBC Section 1202.2. 1 ." b. "Toilet rooms shall be provided with a mechanically operated exhaust system capable of providing a complete change of air every 15 minutes. Such mechanically operated exhaust systems shall be connected directly to the outside from the point of discharge shall be at least 3 feet from any opening which allows air entry into occupied portions of the building. CBC Section 1 202.2. 1 (second paragraph)," �F c. "In all buildings cla55ified a5 Groups 5, F, M, and 5 or portions thereof where Class 1, 11 or li-A llquid5 are used, a mechanically operated exhaust ventilation Shall be provided Sufficient to produce Six air changes per hour. Such exhaust ventilation Shall be taken from a point at or near the floor level. CBC Section 1 202.2.2" G. NONSTRUCTURAL MATERIALS 32 G1a55 and glazing Shall be in accordance with CBC Chapter 24. Note on the drawings all windows and doors having glazing. Indicate the type and thickne55 of each light of glazing on the d rawing5 showing compliance with CBC 5ection5 2403, 2404 and 240G. 33. Note type of Safety glazing complying with CBC Section 240G for hazardous locations listed under CBC Section 240G.4. The following windows require Safety glazing: Storefront 34. Note type of Safety glazing complying with CBC Section 240G for glazing in fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing 15 within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing 15 1e55 than GO inches above the walking Surface. 1-1l4" to 1-1 /2" nominal diameter Gyp bd. Grab bar backing ax. clear Restroom Dimensions 36" Grab Bars 4211 Z 12" 3 2 max. CDx co CIO a m s CD I Accessory heights T 3,_4„ max. 2'-10" 72'-:7" max. 2'-3 2" m1n. min. Knee cleara6" max. nce 17" min. i M-v%o 11111AR� Letters raised 1/32" -----i +eght of lettering"KRO1A ..!58min to 2" max corresponding Grade II braille '- •� �w• rrI r•- i 7" min. T_�_____� 2'-6" I o 0 min. O 19" max. 48" min. Tile cove Wall mounted signage to be located at the latch side of the door clear of door swing. Mount at 60" to centerline of sign from floor �--- Ceramic tile ll t r Lavatory clearances Floor ♦ r surfaces s atrick D e nta- / Desigi Copyright Notice; This material Is owned and Is the sole & exclusive property of Fitzpatrick dental Inc, and Is supplied to the client on a confidential basis soley for use In connection with the project hereon. federal law prohibits the reproduction, display, sale or other disposition of this document without the express written concert of Fitzpatrick Dental Inc, Sheet Title Implem Notes 1& Disability Notes Restroom Details Copyright Notice; This material Is owned and Is the sole & exclusive property of Fitzpatrick dental Inc, and Is supplied to the client on a confidential basis soley for use In connection with the project hereon. federal law prohibits the reproduction, display, sale or other disposition of this document without the express written concert of Fitzpatrick Dental Inc, Sheet Title Implem Notes 1& Disability Notes Restroom Details r� Ratina Indicates existing Solid Core Wood Paintw!O r Obscured glass Single light Note:•i!r hr f rshall i` Accessibility compliant.Lockin Ur r! r` r i i' r ! `ii' `i `i f ii` i i rii ` %ii i `.i To Remain Open During Business Hours" Glazed doors, Type 1 a as shown belowshall have i' "! glass. Full Vision door 1 Solid Core Pocket door Passage •look" Push button Entryi push # #lock Entry'r a .'. # Chrome Pocket door pull 110 loop `�.. ` 777779 5 Restroom Frames: i#! Or 'Confirmi - Norton fj RnIsh: Confirm Lock set:wig Neptune 626 passage lockset Brushed ! chrome ! ConfirmDoor Stop: Harger or equal (1) per door at each locatl Attach blocking to metal stud framing with 1-1/4" # 10 screws (3) screws per stud. Typ. 25G metal studs @16" C Base track - w •� •'f ,''� f Restroom Existing structure 7--1 Attach W42} #10 7/16° _ ._ ._ ._ ._ ._ ._ ._ ._ ..._ .. . panhead screws typ. Attach track to structure above 177" 0 shot n X 1-1/4" min. Embedment ?a 32 - Q.C. ICC #2388 3-5/8" diag. brace 48" Q.C. (3) #10 panhead screws 5/8" Gyp. bd. type' � , Pe metal stud framed wall with 5/8" Gyp, bd, t New Interior partition Insulated, 3-6/8' 25 guage metal stud framed wall with 5/8' Gyp, Bd. type 'X both sides,, provide R13 Insulation. Refer to De -tall "C" on sheet D-6 I Iew low partition 3-6/8" 26 guage metal stud framing with 6/8' type "X7 Gyp, Bd. (2) sides Verify rough ! of iw wall construction# # M w i prior to construction, ExistingNew Interior partition 2-1/2" 26 guage metal stud framed wall with 6/8" Gyp. bd, t�� 'X both sides. exterior wall to remain Existing Interior derrillsing wall to remain Contractor sll verifyall dimensions and site conditionsand make designeraware of adiscrepancies Wateror obstructions which may conflict w/these drawings prior to commencment of construction, r i i!shall be provided allwetareas, (8) All work shall comply with the 2W California Building, Electrical, Plumbing and Mechanical codes, wall surfacesbe prepared i i# painted finish, provide !. !rimer (2) coats color (6) Contractor to provide backing for all wall hung equipment & cabinetry as required. (6) Contractor shall not close any wall or trench containing dental utilities or wall mounted equipment support prior to Inspection and approval by Fitzpatrick Dental, (7) Contractor shall provide structural engineering for all wall and ceiling mounted equipment blocking as required. Contractor s. i O existing ceiling, lighting.# HVAc ducting systems (9) Contractor shall abandon any existing electrical switch or outlet boxes not shown In the electrical drawings on sheet D-3. Walls shall be patched t6 accept new finish. (10) Contractor shall remove all existing floor coverings. Floors shall be prepared to accept new floor coverings T Provide 'fresh air duct In wall for mechanical room ventilation @ 120 A.FF, Refer to HVAC drawings for specifications, �0 Water heater shelf: Contractor to provide plywood shelf for water heater Contractor to provide andInstall Bobrick Moderrecessed paper toweldispenser, roughlin with plumbing a electrical locations, Contractor to provide plywood backing between studs for wall hung vanity countertop al LIGHT AND VENTILATION "All enclosed portions of buildings customarily occupied by human beings Shall be provided with a mechanically operated ventilation 5y5tem. Such mechanically operated ventilation 5y5tem Shall be capable of Supplying a minimum of 15 cubic feet per minute of outside air per occupant during such time a5 the building IS occupied. If the velocity of air at a register exceeds 10 feet per second, the register Shall be placed more than 8 feet above the floor directly beneath. GBO Section 1202.2. 1 ." Provide 2x6 wooden f f • f' f f f rf it 1 • 7 3-5/8" track attached to existing concrete deck 3-5/8" 25 guage metal stud 5/8" Gyp. bd. 3-5/8" lower track ' 3-5/8"lateral brace @ 48" O.C. Note; Use "Flex-C-Track" framing system in all radius soffit locations MW Refer to 4 Tei Fing I IIG ILVYG r s• 1 • 0 Q New Construction 101-10" om 12141 5436 Atlantis Moorpark, • i06 ► 0 Copyright Notice; This material Is owned and Is the sole & exclusive property of Fitzpatrick dental Inc. and is supplied to the client on a confidential basis soley for use In connection with the project hereon. federal law prohibits the reproduction, display, sale or other disposition of this document without the express written content of Fitzpatrick Dental inc, Sheet Title iL�l Symbol Leqend Electrical Symbols CD Mechanical, Provide Vacuum Pump power, 220v 30a S.C. hard wired W/local disconnect, Provide Air Compressor 220v 30a S.C. hard wired W/local disconnect and contactor. Electrician to provide and Install buck boost transforms Telephone/Data wall outlet Provide 3/4'condult drop to single gang ring at Dim, Indicated AFF, NOTE; all conduit must be concealed within wall, all whips to terminate above t-bar celling, Coordinate W/low voltage contractor, to Vacuum pump & Air compressor when available voltage Is below 208v & to make all final connections to equipment, CE Under cabinet lighting; Provide 120v whip for surface mounted florescent fixture mounted Mow upper cabinet 0 Quad Receptacle 120v, mounting height as indicated QD Provide 120v 10a surface floor mount quad receptacle, Coordinate location w/dental utilities, refer to sheet D-3 � Duplex Receptacle 120v 15 AFF, U,O,N, h Indicates horizontal p p @ [ � Provide (4)120v 20A S,C, to modular sterilization cabinet by owner, Refer to product template provided by Fitzpatrick Dental on site =(D 1/2 Switched duplex Receptacle 120v connect to wall switch, mounting height as Indicated 'Inch for exact locations of receptacles on wall, Under cab, lighting, provide continuous tandem light' florescent fixtures connect to switch as indicated cordlnate Cabinet Mounted dental X-Ray unit, Provide 120v 20a s,c, to floor mounted 4s box, Provide (3) # 14 wires to low voltage light fixture lengths wlmiNwork drawings. Fixtures shall extend the entire length of all upper cabinets remote exposure switch locations as Indicated, � Single switch @42' o,c> unless otherwise noted CU Breaker panel; Existing 125A circuit breaker panel, Refer to electrical engineered drawings Recessed Duplex Receptacle 120v flush w/finished floor Electrician to provide 2' conduit from utility box location to cabinet sub base,conduit to be concealed below floor, sweep G,F,I, Duplex Receptacle 120v, mounting height as Indicated ends & terminate In dental equip, j-box. Refer to Detail "L" on D-5 Computer Terminal, 3/4"conduit drop to single gang ring at Dim, Indicated, NOTE; all conduit must be concealed all whips to terminate above t-bar ceiling. Coordinate exact locations of rough -In box with millwork shop drawings. Provide 120v dedicated 10a receptacle at height as Indicated, Refridgerator., Provide 120v duplex receptacle @ 24" AFF. for appliance by owner Low Voltage .�@ X-ray exposure switch; provide 4s box @ 60" AFF, w/single gang ring, provide 1/2' conduit to X-ray unit location, provide pull wire for low voltage cable by others Wall mounted sconce light; provide 120v recessed wall box @84" AF,F,, make final connection to light fixture Contractor to provide complete cabeling systems to Telephone, Computer and stereo systems, Provide and pull all wiring as required to complete the low voltage systems Installations as indicated In the attached drawings, make final connections to switch as indicated, Autoclaves; Owner to make all final wire terminations and connections to Computer and telephone equipment, Provide (2)120v 20a dedicated duplex receptacles, refer to cabinet template on site for location Computer Server; Provide (2)120v 20a S.C. quad receptacles Coordinate with network specialist for computer- spec Is & requirements �4 Microwave; Provide 120v 10A duplex receptacle at height Indicated for under cab, microwave by owner, Mech equip switching. Provide 3-gang box @48" for compressor & Vacuum pump low voltage control panel, provide 1/2" conduit to compressor and vacuum pump equipment location, run low voltage cable provided by others, 16 Modular cabinet, electrician to provide 120V 20A S C, whip, connect to equipment j-box Refer to cabinet template for electrical loads and locations, Electrician to make final connection to modular cabinet by owner. Audio receiver: Provide (1)120v 20a S,C, quad receptacle @78" A,F,F, for stereo equipment by owner, • i • • •. ar ! w • ! s • • •�rit • ir • ♦ ! •'! r..! w • • i (1) All work to be done by a licenced Electrician contractor shall obtain all permits and pay for fees eq• for electricalInspectionsand approvals Including engineering and/or title 24 as t•• :i to complete • allelectricalwork as described herein, electrical (4) Electrician to be available for final connections on the day of Dental equipment Installation All electrical must be fully functional at time of equipment Installation, All Dentalequipment operational on power source of • 60otherwise stated •. • lam. s • connects s towallswitchesas s ,mow"• for on plan and/or required by ••+' (7) All wall mounted outlets shall beunlessotherwise allfinishto besupplied (8) All floor mounted outlets shall be mounted flush with finished floor material unless noted otherwise. Provide carpet rings 9All rough -in dimensionse to CENTER of •s fl Electrician to provide 0 :! • • . • phone equip, power as required, coordinate equipment • (11) Electrician to coordinate locations & heights of all receptacles and outlets W/mIllwork, shop drawings prior to rough -In Electrical permit to be pulledseparately by electrician. Contractor shall X -Ray all concrete surfaces 1 be penetrated prior to coring In post tensionstructures or area where coring may compromise the Integrity of the structure or any existing building systems, (14) Electrician to make final connections to'HardWired" equipment Including dental ! provided others, (15) Electrician to provide Nylon pull strings In all empty conduits, (16) Electrician to provide main service switch gear, transformer, conduit, feeders, panels equipment & services required to complete the Installation as described herein, (17) Electrician to coordinate & confirm all electrical data, phone, audlo and alarm equipment locations and requirements will systems sub -contractors prior tocommencement of work, 1 1/ I !- 1 LADE!' ! * # 1 PERWIT .. ' / AO-ECK + Mf i Alf i.. FOR f UTf tf 01 i • ' 0 R1 i 0. 0 NIN This material Is owned and Is the sole & exclusive property of Fitzpatrick dental Inc, and Is supplied to the client on a confidential basis soley for use In connection with the project hereon. federal law prohibits the reproduction, display, sale or other disposition of this document without the express written conoent of Fitzpatrick Dental Inc, Sheet Title Electrical Plan Plumbing symbols Mechanical: Provide • # O : vacuum piping systembelow grade • pump location to all Dental locations. Provide 1-1/2" vacuum main with 3/4" vertical risers and 3/4" FIP. fittings from Mech. room ro all vacuum terminations, Provide 12x12 floor sink for vacuum pump discharge, Provide complete 1/2" @type 'L' co compressed air piping s stem to all Dental Utility Center and air locations as specified, p r r .• r• ii ■ iis r ! Terminate ■ #•� r# • tseparator• • de # • r t ■0 r • Y on reProvide 12 backflow protected t # water supplyto vacuum pump PlumberrESN NOTE: • make all final,# • to Vacuum pump & Air compressor by owner, i D%Contractori provide w complete piping # rw; Compressed air supply• terminate provide complete vacuum piping system to Include 1-1/2' main line from vacuum pump location to dental utility centers, stub /vertical0 a.ff atutility centerprovide •. fittings at all vacuumlocations, All Vacuum linesbe run below .i plumber to completely flush all air & waterprior to dental equipment r Module[ Dy j• Cabinet Provide H# r Cold Water i Island drain #tr vent, Provide compressed•il All below grade, refer to cabinet template by Fitzpatrick Dental for exact locations & spec's. Plumber to make all final connections Co all plumbing fixtures, Q) Sterile sink: Provide sink utilities for modular cabinet by owner, plumber to make all final connections to faucet and drain provided by others, Provide 1/2" air supply and dishwasher ta�llplece on sink drain for ultra-sonIc cleaner drain connection SLab sink: "Elkay" self rimming stainless steel sink # LR2219 22' x 19"x 75" basin, Provide price Pfister "Genesis" #834-3LC faucet, Install dishwasher tailpiece & plaster trap provided by others, Mim statim Provide cold it supply to eyewashstation fixture provided by owner, Plumber to make all final connections, r Provide air line,terminates compression ball valve atheight• w wi ■ r ar♦ Plumber to make allfinali 0 t to plaster trap provided by others, provide dishwasher tailpiece • make final• # to model trimmer drian. (D Watal Heater: Plumber to provide and Install electric hot water heater w/recIrc pump, refer to engineered drawings for spec Q) WaterProvidesupply, terminate withecompression ballvalve w' heightas Indicated, �uum Valve; Provide 3/4' vacuum valve at 20" AFF, terminate with 3/4" FiP ball valve, t �l� sink; "Kindred" self rimming stainless steel sink #KSSL1719/9M,1"7x 19®x 9", Price Pfister 'Contempra° #526-50CC high arc faucet, (9 Floor aink., American standard #7765,084, or equal, enameled cast Iron,12x12x8 recessed floor sink, chromeON Operat [y sink: Plumber to provide and Install Blanco #BR313D-PS" round stainless steel sink W/PrIce Pfister 'Parlsa� 42 series single faucet, NOTE: Plumbing contractor must coordinate with millwork contractor to confirm sink basin & millwork compatability prior to ordering Cs Plumbing plans !C err w 0 permit w • separate plancheck submittal required) this drawing • reference onlyl NOTE: City water Is not required or supplied to the dental equipment shown In these drawings. Self contained bottled water systems are to be provided at each dental exam room location by dental equipment supplier, Exhaust fan ducted to r19 outside of building i ^ II Disconnect/vac cold water line — Vacuum Pump p (by owner) r i M ll iI II li ll Vacuum pump exhaust to l outside of building "isolated" ll Il II II ll II Il Eel 1-1/2" Vacuum Line E _ J - Floor Sink Provide: # • 1. Amp. to air compressor, Provide magnetic starter ♦ local service disconnect Provide 220v 20Amp dedicated circuit to vacuum pump w/local service disconnect. Provide low voltage remote switch conduit to location as specified on plan. Contractor to pull low voltage cable provided by •. Dental. TAToma'a twinow mm� Plumber #`r to Install Plaster trap, water air valves and any plumbing s1 provided by others. Including automatic faucets, eyewash stations,' Plumber to make allfinal equipment t • to air compressor, Vacuum pump & Air water separator by others, (3) All Vacuum lines must run below grade (4) Plumber to be on site during dental equipment Installation compressed air supplyto Dental equipment t• be 2# prior to equipment Installation. requirements(6) Plumber must be licenced as required to complete this Installation, and shall verify all plumbing Dept. of Building and Safety prior t the Installationof any piping (7) Plumber shall provide & Install required backflow device is) where required by code. • D• not scale plumbing • i from drawlngsill (9) Plumbing permit to be pulled separately by plumber, 0 Contractor to verify penetration lrw. i and site conditions prior i construction forrestrictions or obstructions which may prevent or placement # r • # r t r t r . tany such r # 2�. prior to commencement of • 1 • (11) Plumber to verify all rough -in heights with millwork contractor for 'above splash' locations of air,, water and gas valves prior to termination of OsUneven#i mayrequire heightadjustments of i # dimensions as Indicated. Drain lines from ■■ devices shall terminate V above the floor (13) Contractor shall arrange for all permits, fed s, Inspections, engineering and all related services required to complete all phases of construction as described within these drawings, t-itzpatrick _L _/ Denra Des/sal 1 40 Copyright Notice; This material Is owned and Is the sole & exclusive property of Fitzpatrick dental Inc. and Is supplied to the client on a confidential basis soley for use in connection with the project hereon, federal law prohibits the reproduction, display, sale or other disposition of this document without the express written cone ent of Fitzpatrick Dental Inc, Sheet Title 41 Panasonic Q e •mount exhaust. Contractor to provide and wire to wall mounted switch or thermostat as Tndicated, Coiling fixture box, connect to wall switch as Indicated, Install ceiling light fixture by owner 0 Main D! ! •' i Recessed downlight!n W/Specular relfectorIrim I-Iton #LRBOIC. Indirect low voltage cove lighting: Nora Lighting NDSC-3 Decolume, 12v linear lighting system W/1OW Festoon Xelogen bulbs @3" O.C; Provide remote transformer #NMT1200/12SP and connect to wall swItch/dImmer as Indicated, S Single switch @ 42" O.C, "Decora" style unless otherwise noted T Wall mounted thermostat,i • to equipment ri# Nora #NX-604-1 ED/R/1F Wall or Ceiling mounted edge lit exit sign In accordance with Sections 1012 & 1013 of the UBC. Main: Direct/Indirect 2x4 recessed fluorescent light fixture, Lightoller coffalre #CFS2GPW332UNVO3, Install & connect i-wall switch ..: Indicated, Emergency: Direct/Indirect 2x4 recessed fluorescent light fixture, I-Ightoller coffalre #CFS2GPW332UNVK-l-EM, Install & connect to wall switch as Indicated. Armstrong 'Dune" #1775 tegular 2'x 2' acoustical ceiling tile, Armstrong "SupraRne° 9/16' grid system Provide 2-layers 3/40 plywood 2'x 2' above acoustical ceiling tile, brace to deck above to support dental light by others. Provide 120• i make final connectionsto ceiling mounted light by others. Denotes finished ceiling height AFF,., Confirm all ceiling heights on site, 11MATO "AMO I Mechanical 1. plans unders separate permit 2. Provide access to all plenlum mounted electrical & mechanical equipment & controls located In Gyp, Bd, ceiling locations, 3. Air balance shall be performed by an (NEBB or AABC) certified air balance professional, A copy of the certified report shall be presented to the City of Santa Clarlta building Inspector prior to final approval. 4. All registers and grills Installed In T-Bar ceilings shall be attached at each corner to the main runner with approved clips or small screws, Prr)viriA rAmnto PYhai ict WAs IR Copyright Notice; This material Is owned and Is the sole & exclusive property of Fitzpatrick dental Inc. and Is supplied to the client on a confidential basis soley for use in connection with the project hereon, federal law prohibits the reproduction, display, sale or other disposition of this document without the express written concent of Fitzpatrick Dental Inc. Sheet Title (2) #10 Screws @ ea. brace 3-1/2" x 25ga. MTL. studs @ 16" O.C. w/ batt insulation (STC Rating 49). ICBO #4782 .17 Dia. shot pins @ 24" O.C. Max. 2" off ends (ICBO 1290) Cont. caulking - ea. side Finished surface 42" a.f.f. 3'-6" 2' -611 3-5/8" 25 guage steel stud low wall, confirm heigth w/millwork contractor .......... 3/4" vacuum riser Vacuum main line Mtl. Stud bracing @ 4'-0" O.C. attach to structure above w/ (2) #10 screws @ ea. brace if structure is conc. slab, 45 use (2) "HILTI" anchors - same as bottom Ceilin suspension wires s occurs Acoustical the ceiling B, ,%sceae finish sc edu e Exist. cone, slab W/partitions Provide grommets as required - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 0 0 > - - - - - - - - - - - - - - Dental chair 3-5/8" 20 ga. (icbo #1 715-p) metal stud compression strut @ 12'-0" o.c. and 6'-0" max. from wall 12 ga. bracing wire w/min 4 tight turns in 1-1/2" both ends of wire typical, splayed in 4 directions 90 deg. apart at 12'-0" o.c. and 45 Teg. to ceiling. Support tie wires to t-bar sugrt wires galvanized soft iron # a. min. at opposite corners of a VO" fixture with four full wraps at top and bottom icbo #2244 Recessed flour. fixture Weight of fixture not to exceed 56 lbs Lab provided on the Main ner fixture or install 1/4" run 0 0 0 0 o + 0 0 closed eyebolt Cross tee 8" 110'�' Typ. support 12 ga. vertical 61-01112'-0" o.c, max. hanger wire @ 4'-0" o.c. ea. way w/min. 3 tight turns in No. 12 ga. min. 1-1/2" both ends of wire splay wire -Cross runner Suspended ceiling 45" Horizontal restraints shall be (4) #12 ga. wires \1 8" secured to main runner within 2" of cross runner intersection & splayed 900 from each other at an angle not exceeding 4e from the plane of the ceiling, these horizontal restraint points shall be placed 12ft. o.c. in both directions w/the first point within 4 ft. from Main runner ea wall att chm nt f th r tr int wir s ' o the structure 2" max. from bracing wires to cross runners t above shall be adequate for the load imposed. provide vertical restraint ( 1/2" pipe over suspension wire) @ 8'-0" o.c, ea. way to resist uplift. z5uspenc All Cabinets shall be flush o LCeiling/soffit overlay coast, w/finished enpaneols on all nosed f surfaces upper & over cabinets. Interiors surfaces to be finished in white melamine Varies Upper cabinets shall extend to Shelf Wo. soffit where soffit conditions T71 exist. 32 mm adjustable system W/2 shelves per upper cab. U.O.N. 1 __7 under cab. light 4" chrome pull hardware U.O.N. 0 post formed Var'es concealed 3" under cab. Ight well w/full length door coved splash I provide full extension drawer r - - - - - - - - glides in all dental cabinets L - - - - - - - - provide Accuride 15olb full extension glides in file drawers 2'-1 0'" Max. 32 mm adjustable system W/2 <-, —5/8G " yp. dim, varies shelves per lower cab. u.o.n. 0 C) 2" conduit T_ Dental Cab. by owner <-- Dim, varies---) Dim varies 120V 1 Oa floor recpi .......... .............. ............................ .......... . .......... ......... ........ 1/2" air supply 1/2" electrical 211 conduit to base cabinet V14 1/2" conduit refer to note 7 on sheet A3 120v duplex 0 eratory / Corridor section ma- 120v duple 1/2" Air Iff 3/8" min. c1r. cross or main runner 3/8" min. clear Acoustical the on suspended grid system (2) #10 Screws @ ea. brace 3-1/2" x 25ga. MTL. studs @ 16" O.C. w/ batt insulation (STC Rating 49). ICBO #4782 .17 Dia. shot pins @ 24" O.C. Max. 2" off ends (ICBO 1290) Cont. caulking - ea. side 45 Mtl. Stud bracing @ 4'-0" O.C. attach to structure above w/ (2) #10 screws @ ea, brace if structure is cons, slab, use (2) "HILTI" anchors - same as bottom Ceiling suspension wires as occurs • B.Tse-s?e finish sc edu e Exist. conc. slab co C? Copyright Notice; This material Is owned and Is the sole & exclusive property of Fitzpatrick dental Inc. and Is supplied to the client on a confidential basis soley for use In connection with the project hereon. federal law prohibits the reproduction, display, sale or other disposition of this document without the express written concert of Rtzpatrick Dental Inc, dy AS 11111 �i OF of #. it �/ y � ► �J Copyright Notice; This material Is owned and Is the sole & exclusive property of Fitzpatrick dental Inc. and is supplied to the client on a confidential basis soley for use In connection with the project hereon, federal law prohibits the reproduction, display, sale or other disposition of this document without the express written concent of Fitzpatrick Dental Inc,