HomeMy WebLinkAbout10151686.pdfi uoTEs 1, CONTRACTOR SHALL, PRIOR TO COMMENCEMENT OF WORK, FIELD VERIFY ALL EXISTING PROJECT CONDITIONS, INCLUDING DIMENSIONS AND UTILITY LOCATIONS AND UTILITY SIZES. CONTRACTOR SHALL VERIFY, AND BE RESPONSIBLE FOR, ALL WORK AND MATERIALS - INCLUDING THOSE FURNISHED BY SUBCONTRACTORS, WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES,DO NOT SCALE DRAWINGS TO DETERMINE ANY LOCATIONS, THE ARCHITECT SHALL BE NOTIFIED OF ANY DISCREPANCIES, PRIOR TO CONTINUING WITH WORK. 8, ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITIONS OF ALL APPLICABLE BUILDING CODES, THE AMERICANS WITH DISABILITIES ACT, AS WELL AS ALL OTHER LOCAL GOVERNING CODES AND ORDINANCES. 3. ALL ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL LEGALLY CONSTITUTED AUTHORITIES HAVING JURISDICTION, 4, THE GENERAL BUILDING PERMITS SHALL BE PAID FOR BY THE OWNER AND SECURED BY THE GENERAL CONTRACTOR, ALL OTHER REQUIRED PERMITS SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR OR SUBCONTRACTOR DIRECTLY RESPONSIBLE, 5, CONTRACTOR SHALL ASSIST OWNER IN OBTAINING FINAL APPROVAL OF LOCAL HEALTH DEPARTMENT AND THE TEMPORARY ADN FINAL CERTIFICATES OF OCCUPANCY, 6, CONTRACTOR SHALL PROVIDE BACKING FOR SUPPORT OF ALL WALL, CEILING, AND PARTITION MOUNTED ITEMS SUCH AS LIGHT FIXTURES, SHELVING, EQUIPMENT, AND TELEVISIONS, COORDINATE LOCATIONS AND REQUIREMENTS WITH THE PLUMBING, MECHANICAL, ELECTRICAL DRAWINGS, 7, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, WETHER SHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE, THE CONTRACTOR SHALL BEAR ALL EXPENSE FOR THE REPAIR OR REPLACEMENT OF UTILITIES AND ALL OTHER PROPERTY DAMAGE BY OPERATIONS IN CONJUNCTION WITH EXECUTION OF WORK, 8, CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES, CONTRACTOR SHALL PROVIDE REQUIRED PROTECTION INCLUDING, BUT NOT LIMITED TO, SHORING, BRACING, AND ALL OTHER SUPPORTS (INCLUDING ENGINEERING OF SYSTEMS) NECESSARY TO MAINTAIN OVERALL STRUCTURAL INTEGRITY OF THE BUILDING, ALL DEMOLITION AND CUTTING SHALL BE PERFORMED IN A MANNER AND BY THE METHODS WHICH ENSURE AGAINST DAMAGE TO EXISTING WORK, 9, INTERIOR WALL AND CEILING FINISHES SHALL NOT EXCEED FLAME SPREAD CLASSIFICATIONS DICTATED BY ALL APPLICABLE BUILDING CODES, 10, GYPSUM BOARD AND SUSPENDED CEILING SYSTEMS SHALL CONFORM TO ALL LOCAL GOVERNING BUILDING CODES AND ORDINANCES, 11, ALL GLASS AND GLAZING SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES AS WELL AS THE U.S, CONSUMER PRODUCT SAFETY COMMISSION, SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS (47 FIR, 13516 TITLE NO. 16, CHAPTER 11, PART 1201), 12, PIPES, CONDUITS, OR DUCTS EXCEEDING ONE THIRD OF THE SLAB OR MEMBER THICKNESS SHALL NOT BE PLACED IN STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED, REFER TO MECHANICAL, ELECTRICAL, PLUMBING, ADN STRUCTURAL DRAWINGS FOR LOCATION OF SLEEVES AND OTHER ACCESSORIES, 16, EXTERIOR ❑PENINGS SHALL COMPLY WITH ALL SECURITY REQUIREMENTS AS OUTLINED IN ALL LOCAL BUILDING CODES AND ORDINANCES, 18, ROOF OBSTRUCTIONS SUCH AS TELEVISIONS ANTENNA, SOLAR PANELS, AND GUY WIRES SHALL NOT BE LOCATED OR INSTALLED IN SUCH A WAY AS TO PREVENT FIRE DEPARTMENT ACCESS OR EGRESS IN THE EVENT OF A FIRE, Contractor Shall verify all requirements, material 5pecification5, conditions and dimen5ion5 Shown on plans against actual job site, floor plan and manufacturer's requirements to check for any required tolerances for foundation layouts, Such a5, gap at mod -lines. Notify Engineer of the following: abnormal conditions, deficiencies, di5crepancie5, clarification, m15under5tanding5, typos, m15take5, items mi55ing from drawings, m1551ng reference, deta115 or notes before proceeding, 2. There should be a construction meeting before proceeding with construction. NOTE: SEPERATE PERMITS ARE REQUIRED FOR EACH (BUILDING), (ACCESORY BUILDING), (POOL OR SPA), (FENCE/WALL), (RETAINING WALL), (MECHANICAL), (ELECTRICAL), (PLUMBING). DESIGN LOADS: ROOF LIVE LOAD: FLOOR LIVE LOAD: ROOF DEAD i LOAD: LOAD- WINDLOAD: 20 psf 40 psf 10 psf 8 psf 70 MPH, EXP."C" �] EXISTING AREA PROPO.SEDAREA AREA TOBEDEMO DPERTY LINE 4°-p„ 5'-0" 12$-0„ 18,-0„ 21'-0„ PROPOSED o o PROPOSED, ADDITION / N o ADDITION 286 S.F.��210 S,F. a M � M C N C EXISTING HOUSE I 0 1013 S.F. N o a .p c� . C7 O r 110, 9'-5" 20'-711 1 EXISTING TWO CAR GARAGE 357 S.F. Sliz 100, 20'-2" PROPERTY LINE ' Ca nnnsffn� EXIST. DRIVE WAY 6fit 0 SIDE WALK 0 GRASS c1 GRASS 0 00 RITA WAY 40MO.OW amma k.�.�. SCALE: 1/8" = V-Ott I EXISTING FROAT YARD I OEMI 1 �► L-2001 CALIFORMIA ENERGY CODE (TITLE24, PART 6) 2.-2001 CALIFORNIA BUILDING CODE (CBC) 3.-2001 CALIFORNIA ELECTRICAL CODE (CEC) 4.-2001 CALIFORNIA MECHANICAL CODE (CMC) 5.-2001 CALIFORNIA PLUMBLING CODE (CPC) EXISTING TWO CAR GARAGE AREA SQ. FOOTAGE EXISTING LIVING AREA SQ. FOOTAGE PROPOSED FIRST FLOOR ADDITION AREA SQ. FOOTAGE TOTAL AREA SQ. FOOTAGE LOT SQUARE FOOTAGE LOT COVERAGE LOT TRACT MAP BOOK ZONING CITY COUNTY STATE A.P.N. CONST. TYPE NUMBER OF STORIES YEAR BUILT c 357 S.F. 1013 S.F. 496 S.F. 1866 S.F. 6060 S.F. 30.79 % T-I TITLE SHEET/PLOT PLAN A-1 EXISTING FLOOR PLAN & PROPOSED FLOOR ADDITION PLAN A-2 UTILITY PLAN A-3 ELEVATIONS FOUNDATION ROOF FRAMING PLAN STRUCTURAL DETAILS T-24 TITLE 2 IM REVISIONS DATE BY FIRST ISSUE 10-03-05 SECOND 10-28-05 ISSUE CU n 06 o � m C: p V M 00 > � a, o `C3 N ..� O 00 � M U C7 w � � � W • SCALE: 1/8" = F-Oft SCALE.- 1/811 = it-Otl I m 12' -0" 181-0$$ 61-0*7 _7 NEW w Af.00 NEW NEW (D NEW WALL HEATING @ _ _ _ E 2211 (D d,fly EXISTING NEW I I/ 'W V_ tz (o C (EXIST) ' I 001 BED -ROOM L-�--� N W 001 (00 0 CL I Tk _00 002 5 0', 31, 91-011 0 F ISTTNG 0 `° ( Z (D EXISTING (EUST) BEDROOM 5) S.D OS T 00 2211,, (EXIST:) 1 A A"I , WA ED 3011 001 u 2 CL 001 151-711 NEW NEW 006 D'W'WaRoom TEMP. FRENCH DOOR 00O2 61-01y \3'-0"x 3' "OPEN REMOVE EXIST. DOOR ❑ (EA YST) REF F7+" /+I (EXIST) WABE WALL STINGATING LIVINGROOM\ z (),��7sz) REDf 6 �?M 0 TH. ' \, `� (DEXISTING E STING 9'-511 # 20$-7" Two ar AGE -e— EXISTING 20$-2$$ 01 illial Oil' mwitallin .m SCALE -. 1/411 = if -Off IJVE W ILr) LINDR 0 3 NEW J RELOCATED EXISTING ELECTRICAL PANEL (70 AMPS) MAX. 200 AMPS (D E�STING m I I EXISTING FLOOR PLAN SCALE: 1/8" = l'-Ofl DOOR SCHEDULE Sym. SIZE TYPE QUAN. 001 2$-0llx6'-8)2 H.C. SINGLE 5 002 2'-6"x6'-8" H.C. SINGLE 6 003 2$-6"x6'-8$1 SOLID EXT. 1 3/8" THICK 1 004 3'-0"x6'-8" SOLID EXT. 1 3/8" THICK 1 005 4'-0"x6'-8" CLOSET SLIDING DOOR 2 006 6'-0"x6'-8" F.D. SOLID EXT. 1 3/8" THICK 1 006 1 6'-O"x 7'-0", GARAGE DOOR DOOR NOTES: l.- FRONT DOOR TO BE RATED AT 0.54 OR LESS, VERIFY DOOR STYLE WITH OWNER. 2.- EXTERIOR DOORS IN HEATED WALLS TO BE U 0.20 OR LESS. 3.- DOORS THAT EXCEED 50% GLASS ARE TO BE U 0.40 OR LESS. 4.- ALL GLASS WITHIN 24" OF DOORS TO BE TEMPERED. WINDOW SCHEDULE SYM. SIZE TYPE QUAN. 2-6"xS-0" HOR. SLIDING 1 3'-0"x2'-O" HOR. SLIDING 1 3,-0,,x3,-0,, HOR. SLIDING 2 4'-0"x3'-O" HOR. SLIDING 1 4'-0"x4'-0" HOR. SLIDING 3 6'-0"x4'-0" I HOR. SLIDING 6'-0"x5'-=HOR. SLIDING 1 WINDOW NOTES: l.- ALL WINDOWS TO BE VINYL FRAME, MILGARD OR BETTER. 2.- ALL WINDOWS TO BE U-.40 MIN. 3.- ALL WINDOWS HDRS. FOR 8' & 9' CEIL. HEIGHTS TO BE SET AT 6'- 8 WALL LEGEND EXISTING WALL ATrW WALL NOTES. CODES & ORDINATES. I.- SMOKE DETECTORS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS OF i HARD -WIRED SMOKE ALARMS EQUIPPED WITH BATTERY BACKUP. 2,- ALL EXISTING DOORS AND WINDOWS LEADING TO THE PROPOSED AREA SHALL BE WATER PROOF, 3.- ALL SCREENED PANELS SHALL BE REMOVABLE, 4.- WALL COVERINGS IN SHOWERS OR TUBS SHALL BE CEMENT PLASTER, TITLE OR APPROVED EQUAL- TO 70' ABOVE DRAIN, GLASS & GLAZING IS IN ACCORDANCE WITH CBC CHAPTER 24 SECTIONS 2403,2404 & 2406 5.- USE 2x6 STUDS FOR PLUMBING WALLS, 6,- EXISTING 22'x30' ATTIC ACCESS WITH 30' MINIMUM HEADROOM IS LOCATED IN HALL WAY. 7,- PROVIDE ATTIC VENTILATION EQUAL TO 1/150 OF AREA TO BE VENTED, DORMER GALVANIZED VENTS ROOF TYPEl HALF -ROUND SQUARE- TAIL SIZE: 24'x 12' 8.- REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A DOOR, THE FLOOR OR LANDING SHALL NOT BE MORE THAN ONE -INCH LOWER THAN THE THRESHOLD OF THE DOOR WAY, LANDINGS SHALL BE LEVEL EXCEPT FOR EXTERIOR LANDINGS, WHICH MAY HAVE A SLOPE NOT TO EXCEED 1/4 UNIT VERTICAL IN 12 UNITS HORIZONTAL <2% SLOPE). 9.- PROVIDE FIRE BLOKING IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AT THE CEILING AND FLOOR LEVEL AND AT 10' INTERVALS BOTH VERTICAL AND HORIZONTAL, 10.- PLUMING FACILITIES, INCLUDING LAUNDRY FACILITIES, SHALL BE PROVIDED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE SECTION 413.0 AND CPC TABLE 4-1. ll.- IN EVERY BEDROOM AND BASEMENT, PROVIDE ONE OPENABLE ESCAPE WINDOW MEETING (24' HEIGHT AND 20' WIDTH MINIMUM AND A SILL HEIGHT NOT OVER 44' ABOVE FLOOR. OFFICE ROOM CANNOT BE USED AS A SLEEPING BEDROOM, 12.- GLASS AND GLAZING IN DOORS AND ENCLOSOURES FOR BATHTUBS AND SHOWERS SHALL HAVE CATEGORY II CLASSIFICATION PER CBC CHAPTER 24 AND UBC STD. 24-2, SECTIONS 2403,2404, AND 2406, ,,EVISIONS DATE BY FIRST ISSUE 10-03-05 SECOND I ISSUE 0� O Z Z SHEET # REVISIONS DATE BY FIRST ISSUE 10-03-05 SECOND 10-28-05 ISSUE c- WALL LEGEND EYISTING WALL o o .NEW WALL N {� oc N GG V Vll R� d 0 NOTE 4-4 W a 144 t7 GENERAL LIGHTING FIXTURES IN BATHROOM AND KITCHEN SHALL HAVE c F@=AFCI AFCl/ T LAMPS WITH A EFFICANCY OF AT LEAST 40 LUMEN PER WATT. FCI� �} (� 1 DOORS AND PANELS OF SHOWER AND BATHTUB ENCLOSURES EW % GFC = AFCI W AFCI SHOULD BE FULLY TEMPERED, LAMINATED SAFETY GLASS ,.,,,, , ! r.-. r� �„ r� .. , r, _ �_ OR APPROVED PLASTIC. is a wil 1110 i;1111 W SCALE: 1/4" = F-0" 0 0 RELOCATED EXISTING ELECTRICAL PANEL (70 AMPS) MAX. 200 AMPS z Q m 00 TYPICAL INSTALLATION HEIGHTS UNLESS NOTED OTHERWISE WALL FIXTURE CONVENIENCE OUTLET O SWITCH Q � m d Q CABINET i� a, CONVENIENCE 4 -- TV OR PHONE MAX. FLUSH VOLUMES AND FLOW RATES WATER CLOSETS: 1.6 GALLONS PER FLUSH BLOWOUT TYPE EXEMPT) URINALS: 1.0 GALLONS PER FLUSH SHOWERS HEADS: 2.5 GALLONS PER MINUTE FAUCETS: 2.2 GALLONS PER MINUTE (SINKS AND LAVS) VENT TO OUTSIDE AIR APPROVED SEISMIC STRAPS 2'2"x18GA /8%2 1 /2" LAG SCREW WATER` SHALL BE OR OR STRAPPED TO RESIST HORIZONTAL DISPLACEMENT DUE TO EARTHQUAKE UOTION. 18' WATER HEATER AFCI=@ ARC FAULT CIRCUIT INTERRUPTER GFI=@ GROUND FAULT INTERRUPTER $ SWITCH S,D SMOKE DETECTOR CEILING MOUNT FIXT. -0-FAN WALL HUNG LIGHT FIXTURE (W.P) HOSE BIBS/ HOSE SPIGOT WlNON REMOVABLE ANTI-SIPLON DEVICE I-__J7 A, E o� /A 'ATTIC ACCESS 22"J - i ELECTRICAL PANEL - 200 AMP. MAX. ELECTRIC& NOTES MATERIALS 1, ALUMINUM WIRE SHALL NOT BE USE IN ELECTRICAL WIRING WITHIN THE DWELLING UNIT, WORKMANSHIP 1, ALL WORK SHALL BE IN ACCORDANCE WITH ALL CODES, RULES AND REGULATIONS OF GOVERNING AGENCIES AND SHALL COMPLY WITH THE REQUIREMENTS OF THE SERVING POWER AND TELEPHONE COMPANIES, INSTALLATION 1, ALL EQUIPMENT INSTALLED OUTDOORS AND EXPOSED TO WEATHER SHALL BE 'WEATHER PROOF', 2. RECEPTACLES IN KITCHEN AND BATHROOM SHALL BE INSTALLED ABOVE WORK TOP UNLESS OTHERWISE NOTED ON PLANS, 3. RECEPTACLES SHALL BE INSTALLED VERTICALLY AT 12' (APPROX.) ABOVE FLOOR, 4. WALL SWITCHES ARE TO BE MOUNTED AT 42' ABOVE THE FLOOR, UNLESS NOTED OTHERWISE BY THE DESIGNER, 5. PROVIDE TWO 20 AMPERE SMALL APPLIANCE CIRCUITS AT THE KITCHEN, DINING ROOM AND BREAKFAST AREAS, 6, PROVIDE A SEPARATE 20 AMPERE LAUNDRY CIRCUIT, 7, PROVIDE GROUND FAULT CIRCUIT INTERRUPTER (GFI) PROTECTION AND ALL BATHROOMS, POWDER ROOMS, OUTDOOR RECEPTACLES, GARAGES AND KITCHEN COUNTERTOPS, 8, RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6 FEET, MEASURED HORIZONTALLY, FROM AN OUTLET IN THAT SPACE, 9, IN KITCHEN AND DINING AREAS, A RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH COUNTER SPACE WIDER THAN 12 INCHES AND SO THAT NO POINT ALONG THAT WALL LINE IS MORE THAN 24 INCHES FROM A RECEPTACLE IN THAT SPACE. 10, A RECEPTACLE OUTLET SHALL BE INSTALLED IN ANY USABLE WALL SPACE 2 FEET OR MORE IN WIDTH, 11. PROVIDE TWO METHODS OF ELECTRICAL GROUNDING, A. CLAMP AT HOSE BIB. B, ONE ADDITIONAL #4 BAR-20' LONG IN FOOTING AT ELECTRICAL METER LOCATION FOR UPPER GROUND, 12, BATHROOM CIRCUITING SHALL BE EITHERi A) A 20 AMPERE CIRCUIT DEDICATED TO EACH BATHROOM, B) AT LEAST ONE 20 AMPERE CIRCUIT SUPPLYING ONLY BATHROOM RECEPTACLES OUTLETS. 13, BEDROOM BRANCH CIRCUITS WILL BE ARC FAULT CIRCUIT PROTECTED, �V ►�W 000 � M r � J r--i � MQM 40 YEARS COMP. ROOFING W/ # 15 FELT CLASS A 0/ 1/2" CDX. OR OSB PLYWD. SHEATHING 31 12 -.--EXIST. . ' • .. FOUNDATION VENTS STEP STEP SCALE: 1/4" =: F-0" EXISTING FIRE PLACE 40 YEARS COMP. ROOFING W/ 415 FELT CLASS A 0/ 1/2" CDX. OR OSB PLYWD. SHEATHING 12 3 WA J1 A sue L I Oki 9 M Mal k6l SCALE: 1/4" = 1'-0" 40 YEARS COMP. ROOFING W/ # 15 FELT CLASS A 0/ 1/2" CDX. OR OSB PLYWD. SHEATHING 12 3 1 EXISTING FIRE PLACE I" JAYAWk 46W� Lem SCALE: 1/4" = F-0" EXISTING FIRE PLACE 19 NEW Ix8 FACIA 11. _ EXIST. lx8 FACIA NEW I x8 FACIA 0 IN 12 3 j1, NEW lx8 FACIA 1.1 A) I x8 FACIA TO MATCH EXISTING OVER HANG TO MATCH EXISTING. B) PROVIDE ATTIC VENTILATION. THE REQUIRED VENTILATION AREA RATIO IS 11150 OF ATTIC AREA OR 1/300 OF ATTIC AREA IF AT LEAST HALF OF THE VENT AREA IS PROVIDED BY VENTILATORS LOCATED MORE THAN 3 FEET ABOVE EAVE VENTS PROVIDING THE REMAINING PORTION OF THE VENTAREA. USE VENTS: TYPE: HALF -ROUND SQUARE- TAIL SIZE: 24"x 12" OPENINGS SHALL HAVE 114 INCH CORROSION RESISTANT METAL MESH COVERING. (1505.3) C) USE 2 LAYERS GRADE (D) PAPER WHEN STUCCO IS APPLIED OVER PLYWOOD, UBC SEC. 2506A.4 D) GALVANIZED SHEET METAL (28 gauge min.) ROOF VALLEY FLASHING IS REQUIRED. E) MIN, 2 LAYERS #15 FELT @ 3:12 PITCH F) PROVIDE FOUNDATION VENTS AT AROUND FLOOR JOIST (14 pzs.) RECTANGULAR 6NI4" GALVANIZED CONSTRUCTION. OPENINGS SHALL BE AS CLOSE TO CORNERS AS PRACTICAL AND SHALL PROVIDE CROSS VENTILATION ALONG THE LENGTH OF AT LEAST TWO OPPOSITE SIDES. OPENINGS SHALL HAVE 1/4 INCH CORROSION RESISTANT METAL MESH COVERING. 40 YEARS COMP, ROOFING W/ # 15 FELT CLASS A 0/ 1/2" CDX. OR OSB PLYWD. SHEATHING r ALL NEW WIAD ?WS AlUST MA TCHEXISTII I NG (VINYL SINGLE SLIDING) EXISTING FIRE PLACE PROPOSED NEW LEFT ELEVATION SCALE: 1/4" = F-0" 1 REVISIONS DATE I BY FIRST ISSUE 10-03-05 SECOND 10-28-05 ISSUE c- od a v, N cu �.,� �Q 0 I� 1 .r • w r w , , � w 1 r NUT AND WASHER FOR GIRDER ADJUSTABILITY NO UPLIFT 18" SQ X 12" DP CONC, PIERS TYP, )ST SPC Ti pson Strong-e 1 S-1 12' Simpson Strong -Tie` EPB44T —1 POST 10 3 4,_0„ 4,_0„ S-1 TYP, 4x POST, MIN. M1 X 4 STUD 0 16" O.C. 2 X 4 PLATE 2 X 6 FLOOR JOIST . '\2. X '6 SILL PLATE ANCHOR BOLT EMBEDMENT TO MEET REQUIRMENT OF d .' SIMP. HD-2A W/SSTB16 --"6" CONC STEM WALL da ►'7.%1 ♦K #4 X 30" REBAR EMBEDDED AT EXISTING FTG. ON 1" DIA. HOLE WITH EPDXY ET 22 SPECIAL INSPECTION REQUIRED 4 S-1 4,-0 �1 CD Fc 5� I d 18' SQ X 12' DP CD SQ _ — 4X6 GIRDER HD2A CONC, PIERS TYP, I �2N ! I 4x4 PO T SEE DETAILS I I 10 4T�� p°�� (( d- I I 10 1 2 xbz� I 6� ---��- Fc g� I I 2X6 FLR JOIST ( �°� 10 I 18' SQ x 12" DP I @ 16' ❑, TYP, I I CD —1 4X6 GIRDER CONC, PIERS TYP, 06, SEE DETAILS 1 2 ( I pO—_--- --- ) S-1 S-1 EXISTING FOUN ATION --___---------- EXIST co I CD 6 ( I —1 z #4 X 30 DOWEL @ TOP I < & B❑T BED 4" INT❑ I 2X6 F ❑IST I Pl EXISTIN CONC FTG, @ 16"t—p ❑ C, TYP, I I n SEE DE AIL 4 I I ( M S-1 10 I I I IX _ 1 I I I LJ I I I I I I MIN, OF 6" GAP I I I I BETWEEN 4x6 AND FOUNDATION) I I 10 9,-0„ r-1 Fr"OUNDATION PLAN SHEAR WALL SCHEDULE Spik A3/8" CDX PLYWD OR ❑SB W/ 8cl COMMON NAILS @ 2xpressure t 6"0,C, E,N, & 12" ❑,C F,N,, EXTEND FROM TOP PLATE 2xFACIA TO TO MUD SILL, MIN, 4"-0" WIDE, SIMP, A35 @ 24" ❑,C, EXISTING AT TOP PLATE TO RAFTER W/ SOLID BLK'G, TYP. 16d @ 6" ❑,C, @ SOLE PLATE 5/8" DIA, A,& W/ 2" X 2" X 1/4" PLATE WASHER 9 @ 48" ❑,C. AT MUD SILL PLATE, S-1 1, N❑TCHING AND BORING OF JOISTS SHALL NOT EXCEED CBC SECTI❑N 2320,8,3 ALLOWANCES, 2, NOTCHING OF EXTERIOR AND BEARING/NON BEARING WALLS SHALL NOT EXCEED 25% / 40% RESPECTIVELY, BORED HOLES IN BEARING/NON BEARING WALLS SHALL NOT EXCEED 40% / 60% RESPECTIVELY, IN NO CASE SHALL THE EDGE OF THE BORED HOLE BE NEARER THAN 5/8" TO THE EDGE OF THE STUD, 3, FOR HEADER AND TRIM DETAIL SEE 8—S1 lw 4, ALL PLUMBING WALLS ARE TO BE FRAMED WITH A l E MINIMUM OF 6" STUDS, / 5, PR❑VIDE FIRE BL❑CKING IN CONCEALED SPACES OF STUD WALLS I i AND PARTITIONS, INCLUDING FURRED SPACES AT THE CEILING AND FLOOR LEVEL AND AT 10 FT, INTERVALS BOTH VERTICAL AND H❑RIZ❑NTAL, (708,2) l l 6, THE HOLD—DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTI❑N, (1605,22) 7, FOUNDATION ANCHOR BOLTS IN WALLS SHALL HAVE AN APPROVED PLATE WASHER UNDER EACH NUT; AND THE NUTS SHALL BE TIGHTENED JUST PRI❑R TO COVERING THE WALL FRAMING, PLATE WASHERS A MINIMUM OF 2" BY 2" BY 3/16" THICK SHALL BE USED ON EACH B❑LT,Q806,6,1) 5 S-1 AFTERS CEILING JOIST 12"O.C. EXISTING BLDG. I NEW ADDITION EXISTING FOUNDATION 3/4" T & G PLYWD FLOOR SHT'G. P.I. 32/16 W/ 6" E.N. & 10" F.N. LUS26 HANGERS (SET IN KERF CUT) fVP UON .2X6 FLOOR JOIST 0 16" O.C. 2X6 LEDGER W/ 3/8" DIA. LAG SCREW 0 12" O.C. STAGGERED SIMSI STRAP _ EVERY 32" OC (MATCH EXIST)[ 2x RIDGE BOARD_- --J. PER PLAN COLLAR TIE 2A 0 32" O.C. LUS26 HANGERS (TYP LION SET IN ERF CUT) 7 ROOF AT RIDGE S-1 Yi" (MIN) ROOF SHEATHING .2x RAFTERS PER PLAN `(MATCH EXIST) / 2-2x4 TOP PLATE 4- 4X 4X HEADER zx 1-20 TRIM STUD W/ 16d 0 12" C.C. S-1 16d TO HEADER 4 KING STUD REVISIONS DATE I BY FIRST ISSUE 10-12-05 SECOND 10-28-05 ISSUE hh� 0 O U �\ `-p— l y2 t- N Si1 T/11� > cd NN 'A I C/� k � �J � a Q o W � a W � � CT Z H W � � � H � W r­0 C� 1g-Tie p) SHEET # 'LATES ... Mandatory Measures Summary: Residential MF-1 R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersedes the items marked with and asterisk (*) below. When this checklist Is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or Initial applicable boxes when completed or check N/A if not DESCRIPTION ENFORCE - applicable. N/A DESIGNER MENT Building Envelope Measures ■ 160(,): Minimum R-1 9 In wood ceiling insulation or equivalent LI-factor In metal frame ceiling. El 91 El 150(b): Loose fill insulation manufacturer's labeled R-Value: 0 R1 EJ 150(.): Minimum R-1 3 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not 11 apply to exterior mass walls). 150(d): Minimum R-1 3 raised floor insulation in framed floors or equivalent 1.1-factor. 11 1 50(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs, 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of the firebox 11 ❑ b. outside air intake with damper and control, flue damper and control El El 0 2. No continuous burning gas pilot lights allowed. ❑ 91 D 150(f): Air retarding wrap installed to comply with 111511 meets requirements specified in the ACM Residential Manuel, El El 0 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. KI 0 11 150(l): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor KI 11 El permeance rate no greater than 2.0 permAnch. 118: Insulation specified or installed meets insulation Installation quality standards. Indicate type and inciude El El R CF-6R Form: 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U-Factor, certified Solar Heat Gain ❑ Pq r Coefficient (SHGC), and Infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and seated. Space Conditioning, Water Heating and Plumbing System Measures 1110.13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. 0 D 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. I 50(i): Setback thermostat on all applicable heating and/or cooling systems. El 1500): Water system pipe and tank insulation and cooling systems line insulation. I. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation F-1 P9 ❑ having an installed thermal resistance of R-1 2 or greater, 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external P9 11 11 insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R-value. 3. The following piping is insulated according to Table 150-AJB or Equation I 60-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire P9 R El length of recirculating sections of hot water pipes shall be Insulated to Table 1506. P9 ❑ 11 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heafing source and indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. 29 11 El 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, P9 and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation, L i El El 150(m): Ducts and Pans 1. All ducts and plenums installed, sealed and Insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, EXI 0 El 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used, 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than y 0 El sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional area of the ducts, 3, Joints and seams of duct systems and their components shall not be seated With cloth back rubber adhesive R El El duct tapes unless such tape is used in combination with mastic and draw bands. 2 El El 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned spew have either automatic or readily accessible, manually operating 2 ❑ El dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment 0 [9 0 maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. R El El 7. Flexible ducts cannot have porous inner cores. J 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on -off switch mounted outside of the RX 0 ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed With: a. At least 36' of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. RX 1:1 11 3. Pool system has directional inlets and a circulation pump time switch. [i] El El II 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously R El E. burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btuthr) 118 (1): Cool Roof material meets specified criteria Fxl El El Lighting Measures I 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 0 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, 11 luminalre has factory installed HID ballast. 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined 0 ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires, ❑ lil El OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, arages, laundry rooms, and utility rooms behig luminaires less than 70 ft) OR by dimmer OR ❑ Mx 11 shalt efficacy (except closets are con?, oiled a switch are controlled by an occupant sensor that complies with Section f 19(d) that does not turn on automatically or have an always on option. 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ E El certified to ASTM E283 and labeled as air fight (AT) to less than 2.0 CFM at 75 Pascals, 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the 11 I -XI 11 same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section I 19(d). I 50(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. [il El El Lighting for parking garages for 8 or more vehicles shall have fighting that complies with Section 130, 131, and 146. 150(k)8: Permanently Installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 11 9(d). c14.8 General Requirements 05.8.1 Notes to be placed on the plans: 06.8.1.1 Maintenance Information. The builder shall provide to the building owner at occupancy maintenance information for all features, materials, components, and manufactured devices that require routine maintenance for efficient operation. Required routine maintenance actions shall be clearly stated and incorporated on a readily accessible label. The label may be limited to identifying, by title and/or publication number, the operation and maintenance manual for that particular model and type of feature, material, component, or manufactured device. cl 7.8.1.2 After installing wall, ceiling, or floor insulation, the installer sholl make available to the enforcement agency or post in a conspicuous location in the building a certificate signed by the installer stating that the installation is consistent with the plans and specifications described in Section 10-103(o)2.A and for which the building permit was issued and conforms With the requirements of Part 6. The certificate shall also state the manufacturer's name and material identification. Pmoosed Sancbu Regidence Projebt Title 1-4-11 R Pita WaV tn Ann Project Address En (71418 1 -1124 Docuftntaitffn �Author Te-Icipi- Source Energy Use Standard Proposed Compliance I Btulsf-y Design Design Margin Space Heating 18.71 11.58 7.13 Space Cooling 24.97 21.45 3.51 Fans 5.22 4.32 0.91 Domestic Hot Water 17.09 17.09 0.00 PUMR§ 0.00 0.00 0.00 Totals 65.99 54.44 11.55 0�­A 16-64- 6t- 06--A-voll- 47901- Building Type: [R Single Family 171 Addition Total Conditioned Floor Area: 1,509 ft2 0 Multi Family [R Existing + Add/Alt Existing Floor Area: 1,013 ft2 Building Front Orientation: (West) 270 deg Raised Floor Area: 1,509 ft2 Fuel Type: Natural Gas Slab on Grade Area: 0 ft2 Fenestration: Average Ceiling Height: 8.0 ft Area: 216 ft 2 Avg. U: 0.57 Number of Dwelling Units: 1.00 Ratio: 14.3% Avg. SHGC: 0.65 Number of Stories: I BUILDING ZONE INFORMATION # Of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type t. Area wg*-w Wall wo-ating 286 128 039 Coodifioned Aotback ExiStinCj MIall daalipg 1221 A,7,8A n 81 Coaditinopri Nn Sethank OPAQUE SURFACES Insulation Act. Gains Condition Frame Area U-Fac. Cay. Cont. Azm. Tilt Y N Status JA IV Reference Location Comments M 2raiNZIm 6 wz-i 11 TNT$ I to 2TON0777M 6 AITO was rsr*7= Run Initiation TI-mia: 10/13/05 10:00:24 Run Code: 1129222824 EnergyPro 4.0 by Energypoft User Number: 2448 Job Number., 050805 P!ge:3 of 15 lit Eroposed 5aaghez Project Title Residence Date 1 Q 1131 90-0 5 FENESTRATION SURFACES True Cond. # Type Area U-Factor SHGd Azm. Tilt Stat. Glazing Type Location/ Comments I. ME UM Ivi ` at 11111M. 111,' 2 M-M. VP 10101 RMWCVM�l 2 54 Z no 101 A, U "*i W 161C + 154 R M* a if, M I LSJ to 57M 111i KIM ".11ky'rM11110 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Viodow Oy!grhai3g Left Fin # 1=4P.ri*r.q�r_-iVP Tim-irin R LLs&___A Riahl Ela 3 Bug Screen 0_16 7 Bug aram _5_ Bua Sgoen 0.76 6- pug 9=en ---QjfL 7 BUg gg= 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76. 10 Bug acreen a.76 11 Bug Screen 0.76 12 Bug Screen 0.76 �3 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screeli!n 0.76 16 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) in, Cap. Cond. R-Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R-Val. Location JA IV Reference Status Comments Run initiation Time: 1101131115 IQ:QD:24 Run Code: 112=82A EnergyPm 4.0 by EnergySoft User Number: 2448 Job Number: 050805 Pa2e-4 of 15 LOW Pr used Sanchez Residence 1 0/13L2005 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type New Wall Heating Gravity Wall 71 % AFUE No Cooling 1110 SEER New Setback Existing Wall Heating Gravity Wall 65% AFUE No Cooling 13.0 SEER Existing No Setback Duct Duct Condition Ducts Location Heating Cooling Location R-Value Status Tested? New Wa#I Heat#n Ductless / No Fan Ductless n/a n/a New No Existing Wall Heating Ductless / No Fan Ductless n/a n/a Existing No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Water Heater System Name Type Distribution EwcnaiNhk #in C p SVSt. wMaij Energy Condition Factor Status or RE 1 Standby' Tank Insul. Loss R-Value %) Ext. Existing 60 gallon Small Gas No Pipe Insulation 1 28,000 60 Existing 0.52 We n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP !We In Plenum Outside Buried Insulation I For small gas storage (rated input - 75000 Bturnr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts I and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Christopher S. Leighton 'et/ri- 411,-,Ixeg-4, Name; Title/Firm: Residential Drafting & Design Title/Firm: Terry Engineering Address; 3850 West Hazard Avenue Address: 13691 Red Hill Avenue Santa Ana, Ca 92703 Tustin, CA 92780 Telephone: (714) 265-2788 Telephone: (714) 838-1124 Lic. #: m t�� (signature) a {signature a EnforcemeZA'agency Name: Terry Engineering Title/Firm: 13691 Red Hill Avenue Address: Tustin, CA 92780 Telephone: 7114-8,38-111124 L-dq IN Run Initiation Time: 10/13/05 1 UPON COMPLETION OF CONSTRUCTION: CONTRACTOR SHALL OBTAIN CF-6R FORMS FROM THE CALIFORNIA ENERGY COMMISSION AT: www.energy.co.gov/Citle24 (CLICK TO FIND RESIDEN71AL COMPUMCE FORMS) THESE FORMS SHALL BE COMPLETED, SIGNED AND POSTED ON THE JOB SITE FOR THE PERUSAL OF THE INSPECTOR PRIOR TO FINAL INSPECTION. Z ry L1J LLJ Z 0 Z T"IN g4 a -1"4 LAJ Cie n9Z H. jet No. 1 7014 Ar Exp, 3-31-M At 0 00 < < V) s. tL ry 0,❑ < uw) < V) 0 Z o < ry n V) LLJ ry LAJ V) ry 00 L1_ 1-..- ry o 04 Z < Date: 10-13-2005 Seale: AS NOTED Dram- CL Checked: JT Plot Date: 10-13-2005 Job No: 050805 Sheet: i 24