Loading...
HomeMy WebLinkAbout10151345.pdfREVISIONS Ell] 00 DE v FMMI (E) NEW EXISTING tPROPOSED ADDITION 7 z SOUTH ELEVATION SCALE 1/4'14-0)) (E) (E) NORTH ELEVATION SCALE 1/4 11=11-011 12 zzl 4 (E) (E) .,TOP PLATE C-4 0* %0 El Ilk 'k FINISH GRADEL- (E) PROPOSED ADDITION I EXISTING EAST ELEVATION SCALE 1/4"=1'-0" "PA 1 0 Mi Exterior Cement Plaster/Stucco Finish over 2—Layers of Grade V paper backed Metal Loth color coat and texture to be owners choice Owners Corning Asphalt Shingles Class 'A' (ICBO ES ER #5443) over One Layer of 30# Felt Underlayment and Radiant Barrier 26 Go. Weep Screed Typical Finish Floor Line Finish Grade 14' x 18" Attic Vent 1'-0" Radius Attic Vent 2 x 8 Fascia (Paint Finish) ASSESSOR'S ID # LEGAL DESCRIPTION TRACK # tj rp, I o A .4- ami PLOT PLAN SCALE 1/8"44' 01,92201MIMN LOT SIZE 8760 SQ, FT, (E) ONE—STORY S.F.D. 2145 SQ FT, PROPOSED ADDITION 133 SQ.FT TOTAL AREA PROPOSED 133 SQ.FT, TOTAL AREA 2278 SQ. FT._ 27.0% LOT COVERAGE TYPE OF CONSTRUCTION V—N FIRE SPRINKLERS NO OCCUPANCY R-3 NUMBER OF STORIES 1 STORY LLJ A NORTH I 00 C) F-- < C-D = F-- ZD 0 C/-) C�, C/) a < LL- LLJ LLJ C) < LC') V) Cl- DRAWN JOSE LUIS CHECKED DATE 11-14-05 SCALE NOTED JOB NO. SHEET A \,OF SHEET REVISIONS 21 $41 17 J-311 3 A0 FLOOR PLAN SCALE 1/4"=11-0tf ELECTRICAL SYMBOL SYMBOL DESCRIPTION 0 RECESSED LIGHTING $ SINGLE POLE LIGHT SWITCH Q HARD WIRED SMOKE DETECTOR W/ SO BATTERY BACK UP DUPLEX OUTLET CEILING LIGHT FIXTURE FLUORESCENT LIGHT 40 LUMENS PER WATT. $ GROUND FAULT INTERRUPTER GFI 0 EXHAUST FAN FIVE AIR CHANGES EF PER MINUTE VENT OUTSIDE LEGEND: ] = EXISTING WALLS TO REMAIN r - - - - - - - = DEMO EXISTING WALLS PROPOSED WALLS DOOR 8c WINDOW SCHEDULE 17A = 3$-011X3'-O"DUAL GLAZE SLIDING WINDOW F7B] = 4'-O"X4'-O"DUAL GLAZE SLIDING WINDOW GLAZING ADD SQ, FT. 133 SQ. FT. GLAZE MIN. 13.3 SQ, FT. GLAZE PROVIDED 25 SQ. FT. REMOVED GLAZE 9 SQ. FT. TOTAL NEW GLAZE 16 SQ. FT. MINIMUM 1/10 OF THE ROOM FLOOR AREA I I I c/l) O C) cr-- C/-) C�7 n DRAWN JOSE LUIS CHECKED DATE 10-11-05 SCALE NOTED JOB NO. SHEET A-3 OF SHEET REVISIONS Nailing Schedule Based upon Douglas Fir Framing Members Connection �ailin Post to pier pod, toe nail 3-16d or 4-8d Girder to post, toe nail 3-16d or 4-8d Joist to sill or girder, toe nail 3-8d Bridging to Joist, toe nail each end 2-8d joist to Blocking, end nail 16d top & bottom of each joist Rim joist to joist, end nail 16d top & bottom of each joist Rim joist to sill, toe nail 16d @ 16' o/c Floor joist lop @ bearing, face nail 2-16d 1 x 6 or narrower subfloor sheathing 2-8d to each joist, face nail Wider than 1 x 6 or subfloor sheathing 3-8d to each joist, face nail 2" Subfllor to joist or girder, blind 2-16d and face nail Sole plate to joist or blocking, face nail 16d @ 16" a/c Top plate to stud, end nail 2-16d Stud to sole plate 2-16d end nail, or 4-8d toe nail Doubled studs, face nail 16d 0 24" a/c Doubled top plates, face nail 16d @ 16" a/c Top plates, lops and intersections, face nail 2-16d Continuous header, two pieces set on edge 16d @ 16" o/c along each edge Cealing joist to plate, toe nail 3-8d Continuous header to stud, toe nail 4-8d Cealing joist, lop over partitions, face nail 3-16d Cealing joist to parallel rafter, face nail 3-16d Rafter to ridge 3-8d Rafter ties, 2" lumber, face nail 3-16d Rafter ties I" lumber, face nail ties, 5-8d Rafter to toe nail 3-8d 1 x 4 min. brace to each stud and plate 2-8d face nail 1 x 8 or narrower shothing to each 2- 8d bearing, face nail Wider than 1 x 8 sheathing to each 3-8d bearing, face nail Built up corner studs 16d @ 24" a/c Common or Galvanized Box Nails Roof: Use: 1/2" DF CD-X Plywood W/ 8d Nails @ 6" a/c; 12" a/c Panel lndex 1) New Construction to Be Type V-N. 2) All existing construction to remain Unless otherwise noted. 3) Provide R-13 Insulation on Exterior Walls. 5) Provide R-30 Insulation on Ceiling. 6) Provide Hard wired smoke detectors (Battery Backuf) in all sleeping rooms and one centrally located in adjacent hallway. Provide battery operated smoke detectors in existing bedrooms. Detectors shall sound an alarm audible in all sleeping areas of the unit. 7) Provide 1,6 Gal. Per flush water closets. 8) New Glazing to be Dual Glazed (U-Value 0.75). (SHGC .42) 9) The Governing Codes for this Pro�ect are the 2001 California Building Code (CBC), Electrical (CEC), Energy (T24 6), Mechanical (CM,and Plumbing (CPC) Codes with local amendmets. 10) Bathrooms and Kitchens shall have Flourescent Lighting with at least 40 Lumens per watt. 11) Bathroom Receptacles shall be served by Dedicated 20amp Circuits -NEC Section 210-52(d). 12) Bedroom outlets to be protected by an arc -fault circuit interrupter(s). [CEC 210-12(b)] 13) Any fixed appliance such as disposal, diswasher, clothes washer, dryer, built-in heaters, or any other fixed appliance with 1/4 H.P. motor or larger, shall be on a separate #12 AWG wire branch circuit. Each dwelling unit shall have installed therein an individual disposal circuit supplied with a minimum #12 AWG wire and a 15 AMP indicating -type switch. [CEC 210-23 & 220]. 14) Shower walls must be finished to a height of 70" above drain inlet and moisture resistive tile or approved equal. Glass Enclousure doors and panels must be 1/8" full tempered. 15) Control valves for shower and Tub -Shower shall be of the pressure balance or Thermostatic mixing valve type. Sec. 410.7 UPC. 16) Maximum Flow Rate Standars Set By State of California Energy Commision. A. Water Clostes 1.6 GPF B. Showerheads 2.5 GPM C. Laundry Faucets 2.2 GPM D. Sink Faucets 2,2 GPM 17) Building Address shall be provided on the building in such a position as to plainly be visible and legible from the street. 18) Glass and Glazing requirements: A) Section 2405.4 Hazardous locations. The following shall be consireded specific hazardous locations for the purposes of glazing and shall be tempered: a) Glazing in doors and enclosures for hot tubs, whirpools, saunas, steam rooms, bathtubs and showers. Glazing in any portion of a building wall enclosing enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches (1525 mm) above the drain inlet. 19) Glazing in fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch (610mm) are of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches (1525 mm) above the walking surface. 20) Glazing in fixed and sliding panels of sling door assemblies and panels in swinging doors other than wardrobe doors, 21) ProVifde rain gutters and convey rain water to the street. 22) Water Heater must be strapped to wall. 23) The First Five(5) feet of hot & cold water pipe in unconditioned space are to be insulated per Title 24. 24) An approved backwater valve is required for drainage piping serving fixtures located below the elevation of the next upstream manhole cover. Fixtures above such elevation shall be discharge through the backwater valve. 1/2" O.S.B PLYWOOD 8D NAILS@6" OC. 6"12" OC.— PANEL INDEX 32/16 W/ RADIAN ATTACH TO BOTTOM PLYWOOD. 10 2X6 R.R.016"0,C. — U-1 2X FASCIA BOARD 1,4 2-2X4 TOP PLATE---X-- 4 R-13 INSULATION- 2X4 STUDS@16"O.C.- 2X BLOCKING PLYWOOD WHERE OCCURS 7 /A"UHrPO R-30 INSULATdV,_ A35@24"0,C. D-1 7V -1/2" DRYWALL 1 - 4"CONCRETE SLAB ASPHALT SHINGLES CLASS"A" ROOF FINISH 20 YEARS Mfg. WARRANTY M1 \NEW 2X6FLAT 2X16d PER RAFTER. 2X8 CA@16"O.C. W/6X6-6/6AWF---, 2X4 P/TREAT6� FINISH GRADE STING FTC. EX� P-C A 7W) WEEP SCREED NEW FTC\ 4"SAND OVER 6MIL. VISQUEEN SECTION A —A SCALE 1/4 "= i I- C Shearwall Schedule: AS 15"/32" STD, PLYWOOD STRUCT I ROOF DIAPHRAM: WITH 806" O.C: 3" O.C: 12" O.0 * 1/2 PLYWOOD W/8D NAILS@(6:12)(24/0) EXT PANELS, TWO * ASPHALT SHINGLES CLASS 'A' LAYERS OF 15# FELT * R-30 INSULATION IN CEILING LINDOR STUCCO NELLING R-13 INSULATION IN WALLS (TYP) rim �D Exterior Cement Plaster/Stucco Finish over 2-Layers of Grade V paper backed Metal Lath color coat and texture to be owners choice Q Owners Corning Asphalt Shingles Class 'A' (ICBO ES ER #5443) over One Layer of 30# Felt Underlayment and Radiant Barrier 26 Go. Weep Screed Typical 5 Finish Floor Line 6 Finish Grade 14" x 18" Attic Vent 1'-0" Radius Attic Vent 10 2 x 8 Fascia (Point Finish) Material Specifications Z Notes: 1) Concrete ......... .................................. Standar 2,500 p.s.i. Concrete @28 days. 2) Reinforcing Steel ............. ....................... ASTM A615 Grade 40, 40,000 p,s.i. yield. 3) Framing Lumber ......................................Douglas Fir Larch No 2 Or Better Grade Stamped 4) Plywood diaphragms ................................Product Standard PS 1-95 Douglass fir -Larch, Structural 1 (or CDX) 5) Foundation sills ......................................Pressure Treated, or foundation grade redwood. 6) Provide 2 1/2 "Sq. x 1/4" Plate washers for all anchor bolts. 7) Plate washers are required for all Hold-downs. 8) Anchor Bolts aand hold-downs shall be re -tightened just prior to covering the wall framing. 9) Soil bearing pressure 1DOO psi. 10) Solid Blocking shall be provided at all horizontal joints ocurring in braced wall panels. 11) All diaphragm and shear wall nailing shall utilize common nails or govalnized box. "All bolt holes shall be drilled 1/32 to 1/16 oversized." 12) Bearing wall studs cannot be botched more than 25% of their with. Bored holes cannot have a diameter greater than 40%. 13) Stucco shear wall shall utilize furring, galvanized nails hooving a minimum 11ga., 1 1/2" long, 7/16" diameter head, and furred out a min. of 1/4")o attach the loth to the studs. Staples shall not be used. 14) All diaphragm and shear wall nailing shall utilize common nails or govalnied box. NEW "OR" EXISTING PLYWOOD TO BE VERIFY. (NEW PLYWOOD ON EITHEIRSIDE WALL) (E) (E) 21'-0 " 6 MST37 TIE LLJ 1('8�0"4 D-1 DBL-PLATES fi 15-6it WECC P C-�7--.....----- ---/--- -- ca - 4X6HDR. -0)- HANG1 2X6 R. R no (E)2X6 R.R @ 16" O.0 16" O.C. C.J. 1. 14 C:) 2X6 R.R @ 16" O.0 (E)2X8 C J A 16 O.C' 2X6 C.J. @ 16 O.0 r_9CALIFORNIA ,P-1,)FRAIMING C) 00 .>< ....... clil 1$_01$ I I --------------- i .......... 4X4 ........;. i i SIMPSON GLTV 3-511 3 1/2'X11 7/8' PARALLA 9IL-2 (R-B-2) (E) 2X6 R.R @ 16" O.0 _Ki (E) R.R @ 16" O.0 (E) LAO. C.J. @ 16 O.0 LLJ1 00 >< C14 11-0" IOVERHANG 10 Sim. IH12 cx� 00 1 >< Z PHD2 1 1-0" VERHANG VPHH�2 4X4 'A W/E 0 11,%11,,1'_MST37 TIE_ I DB— I L-PLATES "Alft i NW1 co C-A 00 _D Ln n V) D 0-- ry-) rr, C]r- C� l.-_ C/-) 6-- I I I L-C) Fri n n DRAWN JOSE LUIS CHECKED DATE 8-29-05 SCALE NOTED JOB NO. SHEET A-2 �OF SHEET REVISIONS 7/8- THICK STUCCO OVER LATH PLYWOOD (IF OCCURS) 20016" STUDS 5/8-DIA.X12-'A.B.@48-'O.C, 6X6-10/10 WWF CONTINUOUS FOUNDATION & 2X4D.F. P/TREATED SILL PLATE CONCRETE SLAB TO BE 26 GA WEEP SCREED MONOLITICALLY POURED =E 2% II 4. 2#4 TOP & BOTTOM LL4� C14 =E 12" DRILL HOLE, ADD #4 REBAR FADD SIMP.EPDXY 6 / OR SLEEVE DRYPACK I v 0 2 A ' A Tig' TO #4 RR6A? l 20 ---� 4 A 4 #4 REBA NEW FOOTING EXISTING FOOTING ROOF RAFTER 1/2" PLYWOOD X4 BLOCKING W/ 4-8d NAILS OUTRIGGERS I 8d B.N. @ 6" @ 32" O.C. v , 2X6 FASCIA DBL. RAFTER (IF OCCURS) PER PLAN W/ MST-37 AT SPLICE RAFTERS E.N. 1/2- PLYWOOD 2x CRIPPLE S 0 16" D.C. o A35 @ 11---SIH NAILING IL 16 O.C. x E.N. CEILING JOIST E.N. PLYWOOD SHEATHING (PER SHEAR WALL SCHED.) BN = BOUNDARY PLYWOOD NAILING EN = EDGE PLYWOOD NAILING EXTERIOR CONTINUOUS FOOTING 1 OLD FTG. TO NEW 2 3 4 5 RAKE DETAIL 6 1/4"X3"SIMP, BEAM SEE PLAN SCREWS PER SCH. W/RADIANT I+ + + SIMP.ECCQ ASPHAL,T SHINGLES B RIER CLASSY QR BETTER - 2 CDX PLYWOOD 8d @ 6:6.12 It tl� t - ' CONT. DBLPLATES-- ROOFING PER PLAN G.I. FLASHING WITH "V" CRIMP 2X6 R.R.012"O.C. SIMPSON ST22@4'-O" O.0 0 $1 SIMPSON ECC OR ECCL AT SLOPES LESS THAN 6:12 2X1O C.J.@16"O.C. PLYWOOD SHEATHING 5-16d PER RAFTER -CJ A35@16"-/ 8d @ 6" O.C. POST PER PLAN + + + 2x FACIA + + SPLICE WERE OCCURS SIMPSON MST 48 0 SPLICE ONLY A35 0 32" O.C. E.N. 2' (NO SPLICE@CANTIUVER BEAM PER PLAN � R- 30 INSULATION + + + + I I . 2X LAID FLAT ROOF RAFTERS PER PLAN WITH 3-16d 024" OC SIMP. A-35 OR EQUAL (16- O.C. MINIMUM) VARIES + + + + SEE PLAN 2X-RIDGE OR 2X4STUD016" O.C. PARALLAM, PLS. tit + M. —0 R- 13 INSULATION PLYWOOD SHEATING 2X-C.R.@16" O.0 SIMPSON CCQ 7 + 4o + A + IF OCCURS -1 4-1 d 211X411@32 L4-16d 1/4"X3-SIM 1 @ 2X4 COLLAR TIES 4, O.C. SCREWS PER S H WITH 3-16d EACH END A35016"—/ POST PER PLAN DOUBLE PLATE SPLICE 7 BEAM TO POST CONNECTION 8 CALIFORNIA FRAMING 9 EAVE DETAIL 10 ROOF RAFTER TO RIDGE BOARD 11 12 101 0 4 4 44 4'7 4 CLEAN- REMOVE DUST FROM HOLE WITH OIL- FREE COMPRESSED AIR. CLEAN WITH NYLON BRUSH AND BLOW OUT REMAINING DUST. DUST LEFT IN HOLE WILL REDUCE THE EPDXY'S HOLDING CAPACITY. EN 44 4< 4 FILL—DISPENCE BEAD OF ET OFF TO THE SIDE TO INSERT —ANCHORS MUST BE CLEAN AND OIL FREE. CHECK FOR PROPER MIXTURE(A UNIFORM GRAY COLOR) INSERT ANCHOR, TURNING SLOWLY UNTIL THE ANCHOR BEFORE USING, FILL HOLE HALFWAY, STARTING FROM HITS THE BOTTOM OF THE HOLE. DO NOT DISTURB BOTTOM OF HOLE TO AVOID AIR POCKETS. WITHDRAW DURING SET TIME. NOZZLE AS HOLE FILLS UP. EPDXY TIE EW POST PER PLAN SIMPSON PA51 NAILED TO POST W/16D NAILS AND BOLTED TO EXISTING FOUNDATION A-35 @ SIDE 2- DIA. HILTI RED HEADS EXISTING SILL PLATE OVERPOUR CONCRETE TO PROTECT STARP. (4" MINIMUM EMBEDMENT} EXISTING FOUNDATION 0 -F 1> STEEL REIFORCEMENT I=J PER PLAN. NEW CONCRETE PAD PER PLAN. NEW PLWOOD EITHER SIDE WITH30 OR DOUBLE STUDS EDGE PLWOOD 20 STUDS016"O.C.—WITH NEW PLWOOD /— R-13 INSULATION D.F. P/TREATED SILL PLATE '(N) 5/8 LXOKEMOBNEDTMOEPNTOF SILL SIMPSON EPDXY A.B. M 12"-min EXISTING FTG. TO REMAIN 15 16 X3" SCREW HOLDOWN # OF 1/4- X 3"SCREWS ANCHOR BOLTS post PHD2 10 SSTB16 44 PHD5 14 SSTB20 44 PHD8 24 SSTB28 46 R.R.# 25300/ REPORT# FOR CITY OF LOS ANGELES MPSON STTB ANCHOR BOLT 2. USE SIMPSON MKP (BOLT HOLDERS) FOR PROPER INSTALLATION SSTB ANCHOR BOLTS 3. 1/16- MAXIMUM OVERSIZED HOLE. INSPECTOR TO VERIFY, 4. TIGHTEN ALL HOLDOWN HARDWARE BEFORE PERMISSION TO COVER ROUGH FRAMING HOLDOWN MUST BE SECURE IN PLACE PRIOR TO FOUNDATION INSPECTION 19 PHD CONNECTION DETAIL w HOLDOWN # OF 1/4" X 3"SCREWS ANCHOR BOLTS PHD2 10 5/8-X12- PHD5 14 5/8-X12- USE 5/8"X12"THREAD ROD W/ SIMP. EPDXY A.B. I.C.B.O.#4945 R.R.#25185 DRILL 3/4-HOLE X12-EMBEDMENT DRILL 3/4"HOLE #4 DOWELS@32 & FILL W/EPDXY NEW SLAB 1/4b X3- SCREW EXISTING FOOTING E REBAR p A A7' k #4@1 6"EA. WAY ,EMBED A 1816 THREAD ROD A.B. SEE DETAIL 6 "SPECIAL INSPECTION REQUI%D" Simpson Strong -Tie PHD 17 A35016" BEAM PER PLAI SIMP.HIJ HANGER - NEW SLAB TO EXISTING 2X4@24" A35@1 6" 2X C.J---�\-2X C.J. SIMP.ST22@32"-/ \—SIMP.HU HANGER LSf HANGER PER PLAN FOR R.R. NO-F To 5-cm-e u L M-1 R ��l S, NO, '-043726, Cu op I I I CD D > 0, rn c� C) c.h-- C/-) n n DRAWN: JOSE LUIS DATE: 10-11-05 SCALE: NOTED JOB NO: SHEET D-i 21 OF SHEET CERTIFICATE OF COMPLIANCE : RESIDENTIAL (Page 1 of 3) CF-1R CERTIFICATE OF COMPLIANCE : RESIDENTIAL (Page 2 of 3) CF-1R CERTIFICATE OF COMPLIANCE : RESIDENTIAL (Page 3 of 3) CF--1R REVISIONS ONE— STORY ADDITION 11-14-05 rrolect nme vote 1315 DORREN WAY. SANTA ANA CA� Project Address JOSE LUIS CADENA t213) 715 7938 F*wq Documentation Author e epl hone 8 Compliance Method Package or Computer) Climate Zone FM °/D* GENERAL INFORMATION &bMm't ''th" Only Total Condition Floor Area i33 f#., Average Ceiling Height: $ it, Conditioned Slab floor Area Building TypeSingle Family .._._..Addition (check one or more) Multi —Family ._.._,Existing —Plus —Addition Front Orientation: North/South/East West All Orientations Number of Stories 1 (4d tot wimmu m in tin. Tire Nft ad ck* me) Number of Dwelling Units: Floor Construction Type:Slab wised floe (cram orb a uo) RADIANT BARRIER (requiered in climate zones 2,4,8-15) BUILDING ENVELOPE INSULATION Requiered for this submittal _✓ yes — no Component Type Frame Type wd = wood A = steel Cavity Insulation R—Value Sheathing Insulation R—Value Total R— Valuer Assembly U—Factor L000tion/Comments (attic,goroge,typicoi,etc) Woo WD R-13 R-13 AD EXTERIOR WALLS Wall Roof R-30 R-30 .88 EXTERIOR ROOF Roof Floor F Hear Slab Edge I For escr t've cam li ce. LoLal R— age and Ass bl U—Foctor are nat reVind far awood—from it that meet cgvit R—Vale insulation requieremests for the Prescriptive Package: FENESTRATION Shading Devices ONE—STORY ADDITION 11-14-05 Pra—Vcf TitleDote HVAC SYSTEMS Note : Input hydronic or combined hydronic data under Water Heating Systems, except Design Heating Lead. Hing Equipment Type Minimum Efficiency Distributation Duct or Piping Thermostat Heat Pump (furneatace heat, Pump,e#e.) (AFUE or HSPE) Type and Location R—Value Type Configuration (duets, attic. etc.) (split or oockooes) EXISTING Cooling Equipment Type Minimum Efficiency Distnbutation Duct Thermostat Heat Pump (air conditioner, heat pump, evap. cooling) (SEER) Location R—Value Type Configuration (attic, etc.) (split or packages) EXISTING SEALED DUCTS and TXVs (or Alternative Measures) o Sealed Ducts (all climate zones) (Installer testing and certification and HERS rater field vet ficotion requiered) © TXVs, readily acceslble (climate zones 2 and 8-15 only) (Installer testing and certification and HERS Rater or field verification requiered) o Refrigerant Charge/Air Flow (climate zones 2 and 8-15 only) (installer esting and certification and HERS Rater or field verification requiered) OR © Alternative to Sealed Ducts and TXVs (see Package C or D Alternative Package Features for Project Climate Zone) Climate Zones Window SHGC Window U—Factor SEER Heating WATER HEATING SYSTEMS Water Heater Distribution Number Rated Tank Energy Stand by External Type Type in System input(kW) Capacity Factor or Loss(70 Tank or Btu/hr) (gallons) Recovery Insulation Efficiency R—Value EXISTING 1. For small gas storage water heater (rated inputs of less than or equal to 75.000 Btu/hr.)elctric resistance and heat pump water heaters. Ust Energy Factor. For large gas storage water heaters (rated input of greater than 75.000 Btu/hr),IJst Rated Input. Recovery Efficiency and Standby Loss For instantaneous gas water heaters. list rated input and recovery efficiencies. SPECIAL FEATURES (Add extra sheets if necessary). Package C and D: TXVs, Sealed Ducts, Radiant Berries (sea instalation requierements for radiant barriers in Section 8.13 of the 2001 Residential Manual). Package C : Thermal Mass (thermal mass type, covering, thickness, and description). RADIANT BARRIER REQUIRED ONE—STORY ADDITION 11-14-05 PFo—*t Tie ate COMPLIANCE STATEMENT This certificate of compliance list the bulld'mg features and performances specifications needed to comply with Title 24, Pats 1 and 6 of the California Code of Regulations, and the administrative regulation to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance Is submitted for a single building plan to be built in multiple orientations. Any shading feature that is varied is indicated in the Special Features/Remarks Section. The undersigned recognize that oomprwnce using duct sealing and TXVs requires intaller testing certification and field verificatiloon by an approved HERS Rater. Designer or Owner (per Business and Professions Code) Name: JUAN ESTRADA cite/Firm : Address : 8120 SAN A T IO AVE Telephone Ltc# : Signature Enforcement Agency Name : JOSE LUIS DRAFTING & DESIGN Compliance Forms August 2001 A-2 Compliance Forms August 2001 A-3 Compliance Forms August 2001 MANDATORY MEASURES CHECKLIST: RESIDENTIAL(Page 1 of 2) MF--1R MANDATORY MEASURES CHECKLIST: RESIDENIIAL(Page 2 of 2) MF-1R Note: Lowrise resddentlal buldin s sdubject to the Standard must contain these measurers regardless of the compliance approach used. Items marked with an asterisk �*) may be superseded by more stringent complionce requirre rents listed on the Certificate of Compliance. When this checlist is incorporated into the permit documents, the features noted shall be considered by ail parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this chedist only. Instructions : Check or initial applicable boxes whe completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT YES YES Building Envelope Measures * 150(a) : Minimum R-19 ceiling insulation 150(b) : Loose fill insulation manufacturer's labeled R—Value * 150(c) : Minimum R-13 wall Insulation in wood framed wags or equivalent U—Factor in metal frame walls (does not apply to exterior mass wails). * 150(d) : Minimum R-13 raised floor insulation in framed Boos. 150(i) : Slab edge insulation — water absorption rete no greater than 0.37,, water vapor transmission rate no greater than 2.0 pem%inch. 118 : insulation specified or installed meets insulation quality standards. indicate type and form. 116-17 : Fenestration Products, Exterior doors, and infltratwn/Exlltration Controls 1. Does and windows between conditioned and uncoditioned spaces designed to limit air leakage. 2. Fenestrattion products (except fiel—fabricated) have label with certified U—Factor, certified Solar Heat Gam Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped : all joints and penetrations caulked and sealed. 150(g) : Vapor barriers mandatory in Climate Zones 14 and 16 only. %f) . Special infiltration barrier installed to comply with 151 meets Commission quallity standards. 150(e) : Instation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and foctory—buit fireplaces hone: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2 No continuous burning gas pilot lights allowed. Space Conditioning, Water Heating and Plumbing Stem Measures: 110— 113 : HVAC euipment, water heaters, showerheads and faucets certified by the Commission. 150(h) : Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. 1%Q : Setback thermostat on all oplicable heating and/or soling systems. 150(D : Pipe and tank insulation 1. Storage gas water heaters rater with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or Peter. 2. First 5 feet of pipes closest to water heater tank, non —recirculating systems, insulated (R-4 or greater) 3. Back—up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemol/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 550 F insulated, 6. Piping insulated between heating source and indirect hot water tank. Compliance Forms August 2001 A-5 Note: Lowrise residential buildm s sdubject to the Standard must contain these measures regardless of the compliance approach used, Items marked with an asterisk �*) may be superseded by more stringent compliance requierements listed on the Certificate of Compliance. When this dhedist is incorporated into the permit documents, the features noted shag be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this chedist only. Instructions : Check or initial applicable boxes whe completed or enter N/A if not applicable. DESCRIPTION DESIGNER ENFORCEMENT YES YES Space Conditioning, Waater Heating and Plumbing System Mesasures: (continued) * 150(a) : Ducts and Foes 1. Ali ducts and plenums installed, pled and Insulated to meet requirement of the 1998 CMC Sections 601, 603, 604, and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed mastic, tape, aerosol sealant, or other duct —closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B. If mastic or tape is used to seat openings greater thani/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shag not be used for conveying condioned air. Joints and seams of ducts systems and their components shall not be sedd with cloth back rubber adhesive ducts tapes unless such tape is used in combination with mastic and dmwbands. 2. Building covftnes,eapport platforms for air handers and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support Platforms shall not be compressed to cause reductions in the cross —sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tape unless such tape is used in combination with mastic and drawbods. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventlating systems serving condtioried space have either automatic or readily accessible. manually operated dampers. 6. 6rotection of Insulation, insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limmited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 114 : Pool and Spa Heating Systems and Equipment 1. Systems is certified with 787 thermal efficiency, on —off switch, weatherproof operating instructions, no 603, 604, and Standard 6-3, ducts Insulated to a minimum Installed level of R-4.2 or enclosed entirely in electric resistance heating and no plot light. 2. System is installed with: a. At least 36' of pipe between filter and heater for future solar heating. b. Cover for outdoor pods or outdoor spas. 3. Pod system has directional inlets and a circulation pump time switch. 115 : Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non —electrical cooking appliances with pilot < 15D Btu/hr) 118 (f) : Cool Roof material meet specified criteria. Lighting Measures : 150(k) 1 : Luminaires for general fighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lilghting shall be controlled by a switch on a ready accesble lighting control panel at an entrance to the kitchen. 150(k) 2 : Rooms with a shower or bathtub must have either at least one luminalre with lamps an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the otternatives to this requirement allowed in 150(k)2 : and incandescent recessed ceiling fixtures are 1C (insulation cover) approved. Compliance Forms August 2001 A-6 Documentatbn Author Name: JOSE LUIS 'rifle/Firm : Address : 10210 DOROTHY Telephone : (32)715-798 Lich Signature Date A-4 w Q 00 �� C p C D h^�� G- L1 < l 0_� N rY"> ZD C/ ) w 0 < Fn W F---- M V) C) DRAWN JQAX1)EfS CHECKED DATE 11-14—D5 SCALE NOTED JOB N0. SHEET E-1 OF SHEET