HomeMy WebLinkAbout10138374.pdfAfift n e r 0 N o t e s 1. ALL WORK INCLUDING MATERIALS AND WORKMANSHIP, SHALL CONFORM TO THE REQUIREMENTS OF LOCAL CODES, LAWS, AND ORDINANCES AND THE 1997 UBC AND 1998 CALIFORNIA AMENDMENTS. IN THE EVENT OF A CONFLICT WITH CODE REQUIREMENTS AND ITEMS CALLED OUT ON THE PLANS, THAT CODE OR CALL -OUT WHICH ESTABLISHES THE HIGHER STANDARD SHALL TAKE PRECEDENCE. THE ARCHITECT SHALL BE NOTIFIED OF ALL CONFLICTS. Z. THE CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO CONSTRUCTION AND SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BEGINNING WORK. SHOULD ANY CONDITION ARISE WHERE THE INTENT OF THE DRAWINGS IS IN DOUBT OR WHERE THERE IS A DESCREPANCY BETWEEN THE CONSTRUCTION DOCUMENTS AND THE FIELD CONDITIONS, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 3. DIMENSIONS TAKE PRECEDENCE: DIMENSIONS TYPICALLY TO COLUMN CENTER LINES, FACE OF CONCRETE OR MASONRY, FACE OF FINISH OR AS NOTED ON DRAWINGS. DO NOT SCALE DRAWINGS. 1. CONTRACTOR SHALL FURNISH AND BE FULLY RESPONSIBLE FOR ALL BARRICADES, ADEQUATE SHORING, BRACING AND PROTECTIVE MEASURES PER LOCAL DEPARTMENT OF BUILDING AND SAFETY AND AS REQUIRED FOR SECURITY AND SAFETY. a. ALL GLASS WORK SHALL COMPLY WITH CHAPTER 24 OF THE UNIFORM BUILDING CODE (LATEST APPROVED EDITION) OR LOCAL GOVERNING CODE. S. FIELD COORDINATE ALL FIELD ROUTED PIPE, CONDUIT, DUCT RUNS, ETC..., WITH LOCATIONS OF RECESSED ACCESSORIES AND EQUIPMENT. NOTIFY ARCHITECT OF POTENTIAL CONFLICTS PRIOR TO PROCEEDING WITH WORK. PLUMBING, MECHANICAL AND ELECTRICAL DOCUMENTS ARE DIAGRAMMATIC BY NATURE. THEREFORE, IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO FIELD COORDINATE REQUIRED CLEARANCES WITH THE APPROPRIATE TRADES. ADDITIONAL CHARGES WILL NOT BE APPROVED WHICH STEM FROM LACK OF FIELD COORDINATION. 7. THE CONTRACTOR SHALL PROVIDE AN OVERALL PROJECT SCHEDULE INDICATING CRITICAL MEETING DATES, LEAD TIMES AND DECISIONS REQUIRED. CONTRACTOR SHALL SUBMIT A SUMMARY OF SAMPLES TO BE REVIEWED BY OWNER AND ARCHITECT PRIOR TO BEGINNING THE WORK. 3. ALL EXTERIOR DOORS AND WINDOWS SHALL BE WEATHERSTRIPPED PER SPECIFICATIONS TO MEET CONSERVATION CODES AND STANDARDS. ALL EXTEWRIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWWEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF, BETWEEN WALL PANELS AND AT PENETRATIONS THROUGH BUILDING ENVELOPE SHALL BE SEALED USING THE SPECIFIED SEALANTS AND CAULKING TO LIMIT AIR LEAKAGE. a. ALL GYPSUM WALL BOARD THICKNESS SHALL BE AS INDICATED ON PLANS. ALL OUTSIDE CORNERS SHALL HAVE METAL CORNER BEADS. TYPE "X" GYPSUM WALLBOARD SHALL BE USED AT ALL FIRE RATED PARTITIONS AND WALLS. MOISTURE -RESISTANT GYPSUM WALLBOARD SHALL BE USED AT ALL TOILETS, BATHS AND KITCHENS. 0. THE DRAWINGS INDICATER GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTUCTION MY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER THROUGH THE ARCHITECTS OFFICE. 1. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE SHOWN; THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND HE SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. OBSERVATION VISITS TO THE SITE BY FIELD REPRESENTATIVES OF THE ARCHITECT OR STRUCTURAL ENGINEER DO NOT INCLUDEINSPECTIONS OF THE PROTECTIVE MEASURES OF THE PROCEDURES FOR SUCH METHODS OF CONSTRUCTION ANT SUPPORT SERVICES PERFORMED BY THE ARCHITECT OR STRUCTURAL ENGINEER DURING CONSTRUCTION SHALL BE DISTINGUISHED FROM CONTINUOUS AND DETAILED INSPECTION SERVICES WHICH ARE FURNISHED BY THE ARCHITECT OR STRUCTURAL ENGINEER WHETHER OF MATERIAL OR WORK, AND WHETHER PERFORMED PRIOR TO, DURING, OR AFTER COMPLETION OF CONSTRUCTION AND ARE PERFORMED SOLELY FOR THE PURPOSE OF ASSISTING IN QUALITY CONTROL AND IN ACHEIVING CONFORMANCE WITH CONTRACT DRAWINGS AND SPECIFICATIONS; BUT THEY DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE AND SHALL NOT BE CONSTRUED AS SUPERVISION OF CONSTRUCTION. 2. ALL CONDITIONS SHOWN OR NOTED AS EXISTING ARE BASED ON BEST INFORMATION CURRENTLY AVAILABLE AT THE TIME OF PREPARATION OF THESE DRAWINGS. NO WARRANTY IS IMPLIED AS TO THE ACCURACY OF SAME, HOWEVER, AND CONTRACTOR IS TO FIELD VERIFY ALL CONDITIONS. SHOULD CONDITIONS BECOME APPARENT WHICH DIFFER FROM THE CONDITIONS SHOWN HEREIN THEY SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT OR STRUCTURAL ENGINEER. THE ARCHITECT OR STRUCTURAL ENGINEER WILL THEN PREPARE ADDITIONAL DRAWINGS AS MAY BE NEEDED TO ACCOMODATE THE CONDITIONS AS BROUGHT TO THEIR ATTENTION. . Ate~ - X Wit( I Y7 %f r d x C ct�t i MAMEN I AM mr- - i rEA e"ft em sru u r t m Nam n IN 0 t A co, k S 1. SCHEDULE FIRE DEPARTMENT INSPECTIONS AND TESTS 72 HOURS IN ADVANCE PHONE: (714) 647-5700 2. BUILDING IS NOT APPROVED FOR HIGH -PILED STOCK (MATERIALS IN CLOSELY PACKED PILES, ON PALLETS, OR IN RACKS MORE THAN 12 FEET IN HEIGHT, AND 6 FEET FOR TIRES, PLASTICS, AND SOME FLAMMABLE LIQUIDS). HIGH -PILED STOCK REQUIRES A SEPARATE PLAN SUBMITTAL. 3. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 4. STORAGE, DISPENSING OR USE OF ANY HAZARDOUS MATERIAL SHALL COMPLY WITH THE j LATEST FIRE CODE. 5. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA 10. (-ppr&L®. 11 . at1 Proposed Tenant I prove en t To ■ ev i an t 'i o n c A.F.F. ABOVE FINISH FLOOR F.O.F. FACE OF FINISH O.C. ON CENTER A.B. ANCHOR BOLT F.O.C. FACE OF CONCRETE A.C. AIR CONDITIONING F.O.M. FACE OF MASONRY R.O. ROUGH OPENING F.O.S. FACE OF STUD BD. BOARD F.F. FINISH FLOOR SIM. SIMILAR BLK. BLOCKING FTG. FOOTING S.S. STAINLESS STEEL CLG. CEILING GA. GAUGE T & G TONGUE U AND GROOVE CL CENTER LINE G.I. GALVANIZED IRON T.O.0 TOP OF CURB GYP. GYPSUM T.O.P TOP OF PARAPET DIAM. DIAMETER TYP. TYPICAL DIM. DIMENSION HT. HEIGHT D.F DRINKING FOUNTAIN W.C. WATER CLOSET M.O. MASONRY OPENING W.H. WATER HEATER EA. EACH MAX. MAXIMUM WT. WEIGHT ELEV. ELEVATION MIN. MINIMUM W.W.M WELDED WIRE MESH EXIST. EXISTING MISC. MISCELLANEOUS Wl WITH EQ. EQUAL W/O WITHOUT N.I.C. NOT IN CONTRACT N.T.S. NOT TO SCALE S'Ite :Roof Plan 3 Y�a cy:� z i R r A MW P I • MAlft off Ul le Codc^s I C a 1) 2001 California Building Code (CBC) - Part 2, Title 24, CCR 2001 California Electrical Code (CEC) - Part 3, Title 24, CCR (1999 California Electrical Code and 1998 California Amendments) 2001 California Mechanical Code (CMC) - Part 4, Title 24, CCR 2001 California Plumbing Code (CPC) - Part 5, Title 24, CCR - (Publisher IAPMO) 2001 California Fire Code (CFC) - Part 9, Title 24, CCR PROPERTY LINE l04'--9" EXISTING ASPHALT DRI VEWA Y -0 TO REMAIN Now �--- WHFFI STOP WHEEL STOP -' 0 PROVIDE 70 IN. SQUARE ACCESSIBILITY SIGNAGE AT 80 IN MINIMUM HEIGHT PER CBC SECTION 1129B.5 RESTRIPE EXISTING PARKING STALLS. PROVIDE STRIPING FOR TWO ACCESSIBLE STALLS. PROVIDE PAVEMENT SYMBOL AND STRIPING 36" O.C. PER r.. SECTION w" EXISTING SINGLE -STORY CONCRETE TILT -UP BUILDING B, F-1 OCCUPANCY Q1, .k 'Ca.w 1, i2 53 fA `. N G..: t si apc_ iaogs M s-cq'd "' 3�a.t •t .vm..,rc��+*..nr,raFrta,v..,. a a»w .axaa P.�B" �. A� da./ 6aaA'+vsrwauwnnc.'.v M_nn.aan_ a.v r .. .e-�•t�. .cw.a�eawaww?4v. Nk mot« ���yq .�....�..,� �»�}.,.pg�,� q g S.k A r` 3. S i m "f b. ( d 1 4 6 S"{q. $g'P Mi�6r+8 r` �(�A 4P<... x+ (^'v. b.4 �9 ip t...e ^r,��W$a SUByE"� i C _rt El % a {s_9k Ld r ry P j /v Y— 0-a J t O err (,P" � O Frolect Te OW M S h eeolk l , r �d� OWNER G. A0.1 TITLE SHEET A2.1 FLOOR PLAN Fj � TELFORD A. WALKER "{ P.O. BOX 8083 ° S' `��. A7.1 SCHEDULES NEWPORT BEACH, CA, 92658 A8.1 DETAILS CONTACT TELFORD - � ^ ��°� � � �� TEL:949-644--705$ ; W S0.1 GENERAL NOTES ' r S1 A PLAN AND ELEVATIONS , 1 ARCHITECT S2.0 DETAILS FF ALAN RAY ARCHITECTURE 480 WEST LAMBERT ROAD, SUITE G BREA, CA 92621 a CONTACT: ALAN RAY s ..._ . y v TEL: 714-671-9553 x :,.:, -W FAX: 714-671-9554 v. Ion v . y. STRUCTURAL ENGINEER tC.y., ®� J.T. CONSULTING ENGINEERS ���� 11251 GARDENAIRE LANE' f GARDEN GROVE, CA 92841 CONTACT: JOHN TRAN TEL: 714-530-8575 FAX: 714--530-8575 F M Proiec 5u"MhAhw1A1kA&1ar PROJECT DESCRIPTION: INSTALLATION OF THREE ROLL -UP DOORS AND ONE C) EXIT DOOR IN EXISTING CONCRETE TILT UP BUILDING. CONSTRUCTION TYPE: V-N UNSPRINKLERED OCCUPANCY: B, F 1 EXISTING FIRST FLOOR: 12,377 SO. FT. PROPERTY LINE EXISTING ASPHALT DRI VEWA Y TO REMAIN lw R Alan Ray Architecture 480 West Lambert Road, Suite G Brea, CA 92821 P: (714) 671-9553 F: (714) 671-9554 Stomp: Project Engineer: TSheet Title: itle Sheet U AF VIC11-ftilty map • • IN Air All designs, ideas arrangements and plans indicated by drawings and specification are the property and copyright of the architect and shall neither be used on any other work or disclosed to any other person fior any use whatsoever without written permission from Alan Ray Architecture Edinger Ave.cale: As Shown ve• Job Number: 03-22 >1 Project Manager: ALR VI) Q Drawn By: ALR Checked By: ® .... 'Z3 L C cc 0 Submittal Date: 03-18-03 Resubmittal Date: 03-28-03 - Warner Ave. >" ®c a am � Vite... .... .. .. .... . Ole., ij. at, 7 r' ® _O i1 'A t.t-.. � 3 Oyer R d . FINISH SCHEDULE HARDWARE SCHEDULE DOOR TYPES HARDWARE LEGEND Room Wall Color and Finish Ceilin Ceilin Base Floor HW 1 EACH DOOR TO HAVE: Number Room Name g Q Item Part Number Fin Man Manufacturers Name Abbreviation North East South West Material Heigh Material Material GENERAL FINISH SCHEDULE NOTES: NOTE 1 FLOOR FINISHES SHALL BE SMOOTH AND DURABLE, PER CBC SECTION 420A.9,1.1• NOTE 2 INTERIOR WALL FINISHES SHALL BE SMOOTH, WASHABLE AND DURABLE PER CBC SECTION 420A,9.3• NOTE 3 CEILING FINISHES SHALL BE IN COMPLIANCE WITH TABLE 420A-A, PER CBC SECTION 420A•9.4, NOTE 4 WHERE PATCHWORK IS REQUIRED, REPLACE FINISHES SO THAT PATCH IS NOT NOTICEABLE, 3 Hinge CB1900 - 4-12 x 4 652 STN 1 Lockset CL3320 626 C-R 1 Closer (P) 7500 -BFDA 689 NOR 1 Kick Plate K005010x2 LDW NE 630 TRM 1 Floor Stop 1211 626 TRM I rrt H fty STN Corbin-Ruswin C-R Norton NOR Trimco TRM DOOR SCHEDULE Door Number Room Number Room Name Door Doors Door I Door Frame Frame Details Label Hardware Remarks Type WidthI Height Thick Material I Finish Material Finish I Jamb I Head I Jamb 2 Thres Required Set 102-A 102 Menst Toilet Room A T4 1 6'-8" 13/4" 1 SCWD I Paint I HM I Paint I 14 /A2.1 14 /A2.1 14 /A2.1 15 /A2.1 None 1 SEE NOTE B 103-A 103 Womens Toilet Room A T--0" 1 64 1 13/4" 1 SCWD--I Paint HM I Paint 14 /A2.1 14 /A2.1 14 /A2.1 15 /A2.1 I None 1 SEE NOTE B GENERAL NOTES APPLICABLE TO ALL DOORS NOTE 1 MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED: INTERIOR DOORS - 5 POUNDS NOTE 2 HAND ACTIVATED DOOR HARDWARE SHALL BE CENTERED BETWEEN 30 INCHES AND 44 INCHES ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND BARS ORDOTHEER HARRDWAARE CH ARE iDESIGNED TO PATH OPRO DTRAVE PASSAGE WITHOUTREQUIRINGTHE ABILEITY TO GRABY SP THE OPENING FlA b ARPANIC PERSPUSH-PULLC C SECTIOACTIVATING C1133B.2.5.1, NOTE 3 THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18 INCHES PAST THE STRIKE EDGE FOR INTERIOR DOORS PER CBC SECTION 1133B.2.4.3• NOTE 4 THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC DOORS SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION PER CBC SECTION 1133B.2.6• NOTE 5 THE FLOOR OR GROUND AREA ON WITHIN THE REQUIRED CLEARANCES ON EACH SIDE OF THE DOOR SHALL BE LEVEL AND CLEAR. THE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60 INCHES AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 44 INCHES (48 INCHES IF DOOR HAS A CLOSER) AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION PER CBC SECTION 113313242• NOTE 6 ALL LOCKSETS MUST HAVE NON -REMOVABLE KEYWAYS, NOTES APPLICABLE TO SPECIFIC DOOR(S) NOTE A SMOKE ASSEMBLY DOORS OR SMOKE PARTITION DOORS SHALL BE PROTECTED BY TIGHTFITTING SMOKE AND DRAFT CONTROL ASSEMBLIES HAVING A FIRE PROTECTION RATING OF NOT LESS THAN 20 MINUTES WHEN TESTED IN ACCORDANCE WITH CBC STANDARD 7-2, PART 2, THE DOOR AND FRAME SHALL BEAR AN APPROVED LABEL OR OTHER IDENTIFICATION SHOWING THE RATING THEREOF, FOLLOWED BY THE LETTER "S", PER CBC SECTION 1004,3.4,32.1. NOTE B DOORWAYS LEADING TO MEN'S, WOMEN'S AND UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED WITH SIGNAGE, PER OBC SECTION 1115B.5. EXISTING 2X4 STUDS a 16" O.C. NEW 4X6 BLOCKING, TYP. OVERLAP A35 CLIPS WHERE BLOCKING OCCURS IN SAME LINE IN ADJACENT STUD BAYS EA. END -OCK, INSTALLED AJ ZtNUW N WITH 8d X 11/4" NAILS Blocking Detail Q19---SCALE: None WAINSCOT WHERE OCCURS STAINLESS STEEL GRAB BAR 11/2„ MAX. OUTSIDE DIMENSION 11/411 MIN, OUTSIDE DIMENSION moil LAG SCREWS METAL SLEEVES WOOD BLOCKING, SEE NOTES: MAXIMUM GRAB BAR END CONDITION CANTILEVER 51/2" HANDRAIL SPLICE 6" MAX. FROM MOUNTING BRACKET HANDRAIL TO SUPPORT 400 LB LOAD. Grab Bar Mounting Detail SCALE: None NEW CERAMIC TILE WAINSCOT NEW 42" LONG GRAB BAR �- WITH DIAMETER OF 1-1/211. 1 NEW TOILET TISSUE DISPENSER i N NEW CERAMIC TILE WAINSCOT NEW HC ACESSIBLE PAPER TOWEL/WASTE RECEPTACLE 211 13% 211 EXISTING 1-HOUR RATED WALL WITH INSULATION TO REMAIN !/2" MINIMUM DRYWALL PENETRATION FILL FRAME WITH GROUT AT 1-HOUR RATED WALLS H.M. Door Frame -Head (Jamb Similar} 4 SCALE. None DOR AS SCHEDULED FINISH FINISH MATCH LINE d MATCH LINE Threshold @ Interior Door SCALE: None INSULATE ALL 3 PIPING AND CONNECTIONS 0', LSC mens HC Accessible Toilet Room 1997 UBC and 2001 California Amendments (01 California Building Code — Part 2, Title 24, CCR) 1999 NEC and 2001 California Amendments (01 California Electrical Code — Part 3, Title 24, CCR) 2000 UMC and 2001 California Amendments (01 California Mechanical Code — Part 4, Title 24, CCR) — (Publisher: IAPMO) 2000 UPC and 2001 California Amendments (01 California Plumbing Code — Part 5, Title 24, CCR) — (Publisher: IAPMO) 2000 UFC and 2001 California Amendments (01 California Fire Code - Part 9, Title 24, CCR) 0 EXISTING MENS TOILET ROOM FL M • 111111111111111 MIN! III N 1 1 Z 9E I UJ I I ! 1 N J I 1 7�— ---------- 60" MIN. 1 ® ' DIAMETER CLEAR rN FG36R"AB MIN. o e c PROJECT DESCRIPTION: CONSTRUCTION TYPE: OCCUPANCY: EXISTING FIRST FLOOR: ® � 1 34" MIN M - CLEAR MIENS HC ACCESSIBLE ' TOILET ROOMco 102 ze ono WOMENS 0 HC ACCESSIBLE TOILET ROOM /�`\` 103 \® I 11 N. GRABBAR11 60 MIN. 1 DIAMETER � -- -- --- CLEAR ,v � G� nCL 103-A - I 32" MIN-3011X46 CLEAR ;SPACE CLEAR IAN I I /211 - — — — — — --- I . HI 6011X60t1 LEVEL CLEAR SPACE Enlarged Floor Plan SCALE: V4" = V-0" , r MIRROR W/ SHELF NEW CERAMIC TIL� 21-011 X 31-211 WAINSCOT SOAP DISPENSER NEW HC ACESSIBLE NEW 36" LONG GRAB BAR PAPER TOWEL/WASTE WITH DIAMETER OF 1-1/218 RECEPTACLE am I main ii�iilii�iY/ INSTALLATION OF NEW TOILET ROOM DOORS, GRAB BARS AND TOILET STALL, PARTITIONS V—N UNSPRINKLERED B, F 1 12,377 SQ. FT, i • I a E MICA M O �W 4 NEW HC ACCESSIBLE TOILET WITH FLUSH HANDLE ON OPEN SIDE IIrJVL/111- Ptl-1- PIPING AND CONNECTIONS V) L 0 Overall Floor Plan 3 SCALE:1/16" = V- 0" NEW CERAMIC TILE WAINSCOT NEW 42" LONG GRAB BAR WITH DIAMETER OF 1-1/211. 2411 Q 3 ,9 3 NEW TOILET TISSUE DISPENSER NEW 36" LONG GRAB BAR WITH DIAMETER OF 1-1/211 `-- NEW HC ACCESSIBLE `-- TOILET WITH FLUSH HANDLE ON OPEN SIDE Mens HC Accessible Toilet Room SCALE: V4" = V-0" Alan Ray Architecture 480 West Lambert Road, Suite G Brea, CA 92821 P: (714) 671-9553 F: (714) 671-9554 Stamp: Project Engineer: 2509 Broadway Santa Ana, CA Sheet Title: 102 Mens Toilet Room Paint Paint Paint Paint . Bd. 8'-0" Rubber Base Sheet Vinyl 103 Womens Toilet Room Paint Paint Paint Paint • Bd. 8'-0" Rubber Base Sheet Vin I A J A BBRE, 1, T1_3N CULO.R LEGEND Abbreviation General Description General Color C1 Carpet GL Tempered Safety Glass HM Hollow Metal PLAM Plastic Laminate Pi Paint Color #1 yalls to match existing) P2 Paint Color.#2 (Doors and, Frames) RB1 4" To set Base ST Steel Door by Manufacturer GENERAL FINISH SCHEDULE NOTES: NOTE 1 FLOORING AND BASE TO BE CONTRACTOR FURNISHED, AND CONTRACTOR INSTALLED, CONTRACTOR TO COORDINATE WITH OWNER'S REPRESENTATIVE FOR INSTALLATION. NOTE 2 FLOOR FINISHES SHALL BE SMOOTH AND DURABLE, PER CBC SECTION 420A.9.1.1. NOTE 3 INTERIOR WALL FINISHES SHALL BE SMOOTH, WASHABLE AND DURABLE PER CBC SECTION 420A.9.3. NOTE 4 CEILING FINISHES SHALL BE IN COMPLIANCE WITH TABLE 420k-A, PER CBC SECTION 420A.9.4. NOTE 5 EXISTING FLOOR FINISHES AND FLOOR SURFACES SHALL BE NON-COMBUSTIBLE, PER CBC SECTION 308.2,222. FINISH SCHEDULE Room Room Name Wall Color Ceiling C e'! li n Base Floor Remarks Number and Finish Material Hel hl g Material Material 101 Warehouse VARIES Door Number �Room NumberType Room Name Door Doors Door Material Door Finish Frame Material Frame Finish Details, Label Required Hardware Set Remarks Width Height Thick jamb Head Jamb 2 Thres 10 99 tell] EHOUSE. SEE:NOTES B & C .,.WAREHOUSE SEE N OTE A' WAREHOUSE REHOUSE SEE NOTES B & G WAREHOUSE GENERAL, NOTES APPLICABLE TO ALL DOORS NOTE 1 EXISTING HARDWARE SETS SHALL COMPLY WITH ALL APPLICABLE BUILDING AND HANDICAP CODES, MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 812 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, SUCH - PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS, PER CBC SECTION 11.33B.2.5. NOTE 2 HAND ACTIVATED DOOR HARDWARE SHALL BE CENTERED BETWEEN 30 INCHES AND 44 INCHES ABOVE THE 'FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN THE PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER -TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP- THE OPENING HARDWARE PER CBC SECTION 1133132.5.1, NOTE 3 THE. FLOOR OR LANDING SHALL NOT BE MORE THAN W INCH LOWER THAN THE THRESHOLD OF THE DOORWAY, CHANGE IN LEVEL BETWEEN V4 INCH AND W INCH. SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL IN, 2 UNITS HORIZONTAL (50%SLOPE). CHANGE IN LEVEL GREATER THAN W INCH SHALL BE ACCOMPLISHED BY MEANS OF A RAMP PER CBC SECTION 113313.2.41. NOTE 4 THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18 INCHES PAST THE STRIKE EDGE FOR INTERIOR DOORS PER CBC SECTION 1133B.2.4.3. NOTE 5 THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC DOORS SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR, FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION PER CBC SECTION 11331326. NOTE 6 THE FLOOR OR GROUND - AREA ON WITHIN THE REQUIRED CLEARANCES ON EACH SIDE OF THE DOOR SHALL BE LEVEL AND CLEAR. THE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60 INCHES AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 44. INCHES (48 INCHES IF DOOR HAS A CLOSER) AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION PER CBC SECTION 113313.2,42. NOTE 7 REGARDLESS OF THE OCCUPANT LOAD SERVED, EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT PER CBC SECTION 1003.3J.8. NOTE 8 MAXIMUM EFFORT: TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS, NOTES APPLICABLE TO SPECIFIC DOOR(S) NOTE A ALL DOORS WITH PANIC HARDWARE SHALL HAVE CONCEALED RODS WITHIN THE DOOR. NO SURFACE MOUNTED RODS ARE ALLOWED. NOTE B EXISTING DOOR(S) TO REMAIN, NOTE C EXISTING DOOR(S) PROVIDED WITH PANIC HARDWARE. DuOR 1,0 v,PEb^ TYPE A TYPE B DOOR. HARDWARE SETS HARDWARE N01 (Exterior man -door) EACH TO HAVE: a Alan Ray Architecture 480 West, Lambert Road, Suite G Brea, CA 92821 P: (714) 671-9553 F: (714) 671-9554 Stomp: Project Engineer: Sheet Title: AllAssigns, ideas arrangements and plans indicated by drawings and specification are the property and copyright of the.architeci and shall neither be used on any other work or disclosed to any other person flor any use whatsoever without written permission from Alan Roy Architecture Scale: As Shown Job Number: 03-22 Project Manager: ALR Drawn By: ALR Checked By: Submittal Date: H_ 18-03 At all ,Alan Ray Architecture 480 West Lambert Road, Suite G Brea, CA 92821 P: (714) 671-9553 F: (714) 671-9554 Stomp: Project Engineer: Project Title: An Tenant Improvement For: 2509 ra.wa 2509 Broadway Santa Ana, CA Sheet Title: J^1 Detui.ls All designs, ideas arrangements and plans indicated by drawings and specification are the property and copyright of the architect and shall neither be used on any other work or disclosed to any other person fior any use whatsoever without written permission from Alan Ray Architecture Scale: As Shown Job Number: 03-22 Project Manager: ALR Drawn By: ALR Checked By: Submittal Date: 03-18-03 STRUCTURAL STEEL 1. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED / ERECTED BY APPROVED AND LICENSED FABRICATOR IN ACCORDANCE WITH THE AISC spEcinCATION FOR THE DESIGN, FABRICATION AND EREC11ON OF STRUCTURAL '` BUILDINGS EDITION), # WITH CHAPTER CODE.22 OF THE 2. ALL STRUCTURAL • SHALL CONFORM .!•, ASTM DESIGNATION AS INDICATED BELOWf WFSHAPESA572, GRADE! CONNECTION f PLATES, AND MISC. 6 y BOLTSTUBE SECTIONS BOLTS IN CONCRETE/MASONRY f SHAPESANGLES, CHANNELS, WT • FABRICATOR3. THE STRUCTURAL STEEL STRUCTURAL ENGINEER •S ALL STEEL FOR STRUCTURAL ENGINEERS REVIEW • ! APPROVAL ••• a BEFORE •• FABRICATION. 4. BOLT HOLES USED IN STEEL SHALL BE 1/16" LARGER IN DIAMETER THAN NOMINAL SIZE OF BOLT USED, EXCEPT AS NOTED. 5. ALL STRUCTURAL STEEL SURFACES THAT ARE ENCASED IN CONCRETE, OR MASONRY, SPRAY ON FIREPROOFING, OR ARE ENCASED BY BUILDING FINISH, SHAH UNPAINTED. r; 6. ALL WELDING IS TO BE DONE BY CERTIFIED WELDERS USING E70XX ELECTRODES (UNO). ALL WELDS SHALL BE IN CONFORMITY WITH THE PROJECT SPECIFICATIONS AND THE CODE FOR WELDING IN BUILDING CONSTRUCTION (AWS D1.1 LATEST REVISION) OF THE AMERICAN WELDING SOCIETY. SEE SPECIAL INSPECTIONS SECTION FOR WELDING INSPECTION REQUIREMENTS. USE OF !T­4 WIRE IS NOTPERMITTED. WELDS7. WELD LENGTHS CALLED FOR ON PLANS ARE THE NET EFFECTIVE LENGTH REQUIRED. WHERE FILLET WELD SYMBOL IS GIVEN WITHOUT INDICATION OF SIZE, USE MINIMUM SIZE • ! IN AISC MANUAL OF CONSTRUCTION 9TH EDITION, SECTION •.. ALL EXPOSED STRUCTURAL • i MISCELLANEOUS METAL SHALL BE HOT DIP GALVANIZED AFTER FABRICATION UNO. ,! SPECIAL INSPECTION • BOLTS PROVIDED. FOLLOWINGSPECIAL INSPEC11ONS THE OF i i CONTINUOUS AND/OR PERIODIC• ! ACCORDANCE•N 1701 OF THE CODE AND ANY ADDITIONAL REQUIREMENTS STATED IN THE DRAWING OR spEcinCATIONS . THE INSPECTIONS SHALL BE PERFORMED BY A BUILDING INSPECTOR APPROVED BY THE COUNTY OF LOS ANGELES. WELDING: STRUCTURALALL WELDING,! REINFORCING 2s CONCRETE: CONTINUOUS INSPECTION IS REQUIRED FOR PLACEMENT OF ALL CONCRETE. 3. BOLTS INSTALLED IN CONCRETE 4. SHOT PINS 5. EPDXY ANCHORS EPDXY1. ADHESIVE USED FOR SETTING • AND ANCHORS SHALL BE IN CONFORMANCE WITH ASTM •81, TYPE IV. ACCEPTABLE FOR EPDXY ADHESIVE ARE RAMSET/REDHEAD, SIMPSON STRONG -TIE SET, HILTI HIT HY 1509, OR APPROVED EQUAL. 2. ANCHORS OR DOWELS EMBEDDED EPDXY SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. 3. HOLES RECEIVING EPDXIED ANCHORS SHALL BE CLEAN AND FREE OF DUST PRIOR rir TO APPLYING • EPDXY ADHESIVE. 4. HOLES DRILLED INTO REINFORCED CONCRETE SHALL NOT DAMAGE OR CUT EXISTING REINFORCING LOCATE !!NS USING NON-DESTR METHODS PRIOR TO DRILLING. 5. ALL ANCHORS EMBEDDED IN EPDXY ADHESIVE SHALL HAVE CONTINUOUS SPECIAL - INSPECTION IN ACCORDANCE WITH THE CODE SECTION 1701.5. 6. EPDXY ANCHORS SHALL NOT BE INSTALLED IN THE UNDERSIDE OF FLOORS O: ! SHEET INDEX ................................................................................................................................................. S0.1 GENERAL NOTES S1.0 PLANS AND ELEVATIONS S2.0 DETAILS FOUNDATION BASED1. FOUNDATION DESIGN 2. F001INGS ARE DESIGNED BASED ON THE FOLLOWING INFORMATION: ALLOWABLE BEARING 1000 PSF PASSIVE EARTH PRESSURE 100 PCF 3. CONTRACTOR TO PROVIDE FOR DE -WATERING OF EXCAVATIONS FROM EITHER SURFACE WATER, GROUND WATER OR SEEPAGE, IF REQUIRED. 4CONTRACTOR SHALL PROVIDE •! ! • •. DESIGN AND INSTALLATION AAA,. f OF ALL CRIBBING, SHEATHING AND SHORING REQUIRED AND SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATIONPROCEDURES INCLU ORDINANCES.SHORING AND PROTEC11ON OF ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY 5. EXCAVATION FOR F007INGS SHALL BE PRIOR TO PLACING THE CONCRETE AND REINFORCING. CONTRACTOR • NOTIFY THE INSPECTOR WHEN INSPECTIONOF EXCAVATION IS READY. A i • r TO SUBMIT LETTER OF COMPLIANCE. BEHIND6. ALL EXCAVA11ONS SHALL E PROPERLY BACKFILLED. DO NOT PLACE • INSTALLATIONBACK FILL RETAINING WALLS BEFORE CONCRETE OR GROUT HAS ATTAINED FULL DESIGN STRENGTH. CONTRACTORS SHALL BRACE OR PROTECT ALL BUILDING AND PIT WALLS BELOW GRADE FROM LATERAL LOADS UNTIL ATTACHING FLOORS ARE COMPLETELY IN PLACE AND HAVE ATTAINED FULL STRENGTH. CONTRACTOR SHALL PROVIDE FOR DESIGN, PERMITS AND OF SUCH BRACING. 7. FOUNDA11ONS SHALL BE PLACED AND ESTIMATED ACCORDING TO DEPTHS SHOWN ON DRAWINGS.• 1 SOIL ENCOUNTERED AT THESE DEPTHS NOT BE APPROVED BY THE INSPECTOR, FOUNDA11ON ELEVATIONS WILL •• ALTERED BY CHANGE ORDER. FOOTING8. ! UTILITY TRENCH BACK FILI WITHIN BUILDINGAREA SUPPORTSHALL BE MECHANICALLY COMPACTED IN LAYERS. FLOODING WILL NOT BE PERMITTED. ALL FILLS USED TO i 1 •SHALL INSPECTED BY THE INSPECTOR PER CODE SEC11ON 3301A. 9. ALL ABANDONED; FOOTINGS, UTILITIES, ETC. SHALL BE REMOVED UNLESS NOTE!, OTHERWISE. NEW FOOTINGS MUST EXTEND INTO UNDISTURBED SOILS. 10. SLABS ON GRADE SHALL BE SUPPORTED ON NATURAL GRADE OR COMPACTED CONCRETE 1. ALL ABANDONED FOOTINGS, UTILITIES, ETC. SHALL BE REMOVED UNLESS NOTED OTHERWISE. NEW F001INGS MUST EXTEND INTO UNDISTURBED ALL CONCRETE CONSTRUCTION SHALL CONFORM WITH CHAPTER 19 OF THE CODE AND WITH THE PROVISIONS OF ACI 318, LATEST EDITION. 2. REINFORCED CONCRETE IS DESIGNED BY THE *ULTIMATE STRENGTH DESIGN METHOD 3. CONCRETE MIXES SHALL BE DESIGNED BY THE APPROVED TESTING LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. THE COMPRESSIVE STRENGTH OF THE CONCRETE SHALL BE PROPORTIONED BASED ON SECTION 1905 OF THE CODE. 4. SCHEDULE OF STRUCTURAL CONCRETE 28-DAY STRENGTH AND TYPES: LOCATION STRUCTURE r DENSITY MAX • RATIO ALL CONCRETE FOOTINGS SLAB ON GRADE 4000 150 4 0.50 CONCRETE CURBS, 0.50 AND OTHER NON-STRUCTURAL 5. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE 11. 6. AGGREGATE FOR HARDROCK CONCRETE SHALL CONFORM TO ALL REQUIREMEN AND TESTS OF AND PROJECT r • SPECIFICATIONS. ,• EXCEPTIONS , PLACEMENTBE USED ONLY WITH PERMISSION OF THE STRUCTURAL ENGINEER. 7. CONCRETE MIXING OPERATION. ETC. SHALL CONFORM TO ASTM C-94. 8. OF • TO CODE •1905 AND CONCRETEPROJECT CLEAN AND ROUGHEN TO 1/4" AMPLITUDE ALL SURFACES TO BE PLACED. BARS,9. ALL REINFORCING ENGINEERSHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. 10. PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN CONCRETE BEFORE PLACING. DO NOT CUT ANY REINFORCING WHICH MAY CONFLICT. CORING IN CONCRETE IS NOT PERMITTED. NOTIFY THE STRUCTURAL IN ADVANCE OF CONDITIONS • SHOWN ON DRAWINGS. SLABSTHESE DRAWINGS FOR ADDITIONAL RESTRICTIONS ON THE PLACEMENT OF OPENINGS IN PIPES11. LARGER ! • SHALL NOT BE EMBED! IN STRUCTURAL ENGINEER. PIPES SHALL NOT DISPLACE OR INTERRUPT REINFORCING BARS, SPACE EMBEDDED PIPES AND SLEEVES AT A MINIMUM OF 3 DIAMETERS ON CENTER. STRUCTURAL CONCRETE EXCEPT WHERE SPECIFICALLY APPROVED BY GENERAL 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTIN�t r ! � ! � • ! !- "' it • !# • I • r • • • • VW • r � # • a i � t • • r • r , + • • • i • IF • •` a � i ! 13. DESIGN LOADS: LIVE LOADS: ROOF 20 PSF 14. WIND ANALYSIS PER CHAPTER 16 DIVISION III OF THE CODE Iw= 1.0 (STANDARD STRUCTURE) qs = 12.6 PSF (70 MPH) EXPOSURE= C 1. SEISMIC ANALYSIS PER CHAPTER 16 DIVISION IV OF THE CODE UTILIZING THE SIMPLIFIED STATIC FORCE PROCEDURE. Z = 0.4 (ZONE 4) 1 = 1.0 (STANDARD STRUCTURE) f= 1.0 N®= 1.0 NV= 1.0 R= 5.5 CV = 0.6 Ca= 0.4 2.8 SOIL CLASSIFICATION = SD • t Cienaga Drive, Fullerton, 1: 92835 If • • • • Stamp: !. �•! � fir/ a Y � 1 1 • • • 62 • f • • • ! .''. / StructuralOFF' C • JT Consulting Services 1251 Gardenafre Lane Garden Grove, CA 92841 (714) 815--2356 Fax (714) 530-8575 Project Title: 2509 Broadway Care Center 2509 Broadway Santa Ana, CA Sheet Title: GENERAL NOTES am �� �psrmieeton f�iom Nan �Are the prooerty dipkm � of the aeNheat and Nwq eeiMx be used on any oiha work Scale: Job Number. Project Manager. Drown By: Checked By: Submittal Date: Drawing No.: S 0.1 I I awt I I ... ....................... ............ . ..... I .......... ........... . ........ .... - ... ... ................. .................. .................................. ..................................... .................... ..................... . . . ............. - ....................... ­_ ............ ........... ................ ....... ...... ......................................... ­­ ......... * ...... * ........ ....... ........ ­ ...................... .......................... . ... ..... .. ..... ..... ..... ...... ..... ..... ....... . ..... . .. ..... ............ ..... ... . ............ ..... ..... ...... ..... ..... ..... .. - .. ..... .. .. ..... .... ... . ..... ... ..... ... . ...... C CONC FTG 21 DEEP FIELD VERIFY TYP X 5/ N) T S6 x 6 �6 FOUNOU"' ATION PLAN M I Cq N M 0 16 ............ ............................................. ........ ........ -.1- ............................. .. .................. .......................... ................................. ............ ................. ............... ................... ................................... ........ ... ­.::....,.:..= . ............. .......... ....... ............. .......... ........... .............. .......... ......... .............. ......... ...................................................... ­­ ................ ............ . ............ ...... .................................... ................... ........ .................. ....... ........ ............................. .......................................................... ...... .................................. 9 .................................................. .............. ...... ...... .................. ............ ...... ................... inX ............. ............. ............................ ......... -........................................................................... C4 . .......... .......... X Ix X i X i co ........... (D ............. .......... ............... ....... co .......................... ...................... ....... ........... ............ A co: ............ .......... ....... ............... ..................................... z ........................ ................... ....... ........ .............. ......... .................... ....... ........ ........ ....................... - ................... ............ ............. ............ ......................... ...... 00-% ............ ................. .......... ........... CN ........................ ....... .......... LN X X ..................................... X X z .............. ...... ...... ...... W. ................. ............ ............ rD ................. W ......................................._...................,c............. ................................................... ............... ............................................. ........ ....................................................... ................................................................. ............... ............. ......... ........... ................................. .......... ......................... ............. ............ ......................... ......... - ............. .......... .............. 1.1.1- ...... I ....................... ..... (N) Ts6x6x5/16 I . .......... ............................... - .... .... ...... .......... ........... 2 229-6" 22#-6" 22#-6" 229-6" 22#-6" (E) 2x4 0 VAN lyp 21$-6" '—on 10 —on 2V-6" 31-90. 10 $-ON 7 9-999 .... ... ... .... . ....... ....... ...... ... ... ...... ............. ... ........... .... I ......... .11 ... ................. I ....... I .. ... .............. ........... ... .............. .... ... ... ................ ......... ... ... ........................ ... ... . ........................ ... ... .... .................... ... — — — — — — — — -- - rF� .......... C) . . . . . . . . . . . -7 ,q _ANL� M W IL --ALIL, 9*-699 10 0_011 2 f-O" ............ ........ ... ... .. ................... ... ...... ........ ........ .. ... ........ ...... ..... ....... ... .. ....... ...... - ... ... ... ......................... ....... ........... ......................... ........ ........ .. ......................... ... ... .......................... ...... ................ ... ... ....... ........... ... ... .......................... ... ... ......................... ... ... .............................. -- - - - - - - - - 2 kS2.0,1 . . . . . . . . . . . . . . . . ...... as 1111�� Elm 11"t F/*s1 ON W, Alan Ray Architecture 764 Cienaga Ddve, Fullefton, CA 92835 Phone/Fax: (714) 992-9190 Stamp: Structural Engineer-. JT Consulting Services *51 Gardemire Lane Garden Grove. CA 92841 (714) 86-2356 Fax (N) 530-8575 0 Project Title. 2509 Broadway Care Center Sheet Tiftle.- PLANS AND F71EVATIONS AD dealgro. khm W—KIWI-P.-WHIM1160 afnwd m plar kKkated by dragr -adnd are #w and ght r saw nd or afnwy�Wother pwwn a I without wfitten .1184 AlAlan% Amhbolure of the amlifted a doll neither be used on any other work Scale-, Job Number. Project Manager-, Drawn By: Checked By: Submittal Date-. ROOF rowing o.-. B SAW BLADE NEATLY CUT & CHIP SEE ELEVATION OUT CORNER t (N) 4X4 BLKG W/(1) SAW UT — �' ® STOP WCUT. " SIMPSON A35 EACH SIDE (E) LEDGER (N) OPENING A ~� _ �_ _ _ _ DO NOT OVERCUT CORE 6 � f HOLE 0 CORNERS & SAWCUT. EACH END (4 PER BLKG) _.__ o — — DO NOT OVERCUT OPNG. �-MC 6x12 ± CHIP AWAY FINAL CORNER. .............................................................................................. DETAIL DETAIL TYP TYP ' 3/16�� �. ............. .......... OPNG. (N) 1 /4"X4" PL. /� 2" MIN ...........................::: MC 6x12 ° MC 6x1 ; is ! E E (N) L6X4X 5/16 LLV t t W W/4-1 /2 0 LAG SCREWS / 4 EMBED TYP 3 " w /16 3 e ff (E) CONC. n I PANEL TYP " 0 ELEVATION 3/16 4 ' t ��Qf E 1/2"0 x 4" EMBED W/ (N) TUBE PER ' PROCEDURE z ELEVATION t �'''�'--- ILTI HIT HY-150 0 MIN. OF 4 0 HEADCD ° 1. SHORE BEAMS, JOISTS URLINS, C., SUPPORTED BY WALL. 36" O.C. MIN. OF 3 0 JAMBt C 2. SA CUT AN REMOVE ALL. 3. DRILL ALL HOLES FOR EDGE ANCHORS. 4. INSTALL CHANNEL ® D. MEADCJAMB '� C � 5. INSTALL CHANNEL 0 JAMBS AND WELD JAMBS TO HEAD. t F LAW _ 6. REMOVE SHORES. DETAIL 1 "_ 1,®offOPENINGIN 1 ,f_ 1'-0" PER ELEVATION (E) 6" CONC WALL 3/ "0 x " MIN EMBED W� HILTI HY-150 EPDXY TYP.:.::.:-.-.._.............. ..................... ............................... w F 3/8"x7"x 1'-1 " 5 10TYP f—®ff -- (N) OPENING 2 S PER ELEVATION TOP OF PARAPET ROOF 1 1/2 " 2:.....:.::.:.:...............:.. ....... -.... :...................: :... 1/4 El 12" TYP a El 4 TYP TS6x6x5/16 TYP 4 (E)6" THICK 0- TYP DETAILff f ff ®o CONCRETE 1 = 1 0 1 =1 �-0 PANEL z 3 TYP r' .. (E} 6" THICK............................................................................................................. . FINISHED FLOOR L4x4x 1/qx0'-5" LG TOP & BOTT CONCRETE EACH END PANEL :....................................... .... ...... ............ ................... .............. .......................... ... ........................... ........... ... ... ................ .............. ................................. ........... ....: 7 "x4"E BD TS l6 E PER EL ATION d� THREADED ROD FORNEW OPENING w. EPDXIED W/ " TYP IN CONCRETE ALL of thWilk e HILTI HIT HY-150 i I 1 j4 5 SEE 1 TS PER (TYP0 HORIZONTAL T) i - . ELEVATION I 1/4 3" 0 + -�» i • ___ .�— _......._ -- — N p /2 GA J � w — — { 1 " L4x4x 1/ TYP UNO (N) OPENING 3 " " /q 0 x 4 EMBED & MC ' THREADEDROD - EPDXIED W j INSTALL ALL TUBES i HILTI HIT HY-150 PRIOR TO CUTTING (TYP 0 VERTICAL TS) (N) OPENING � e .. 1/4 NOTE: I?. 1/4" GUSSET INSTALL L TUBES � _y � __._ .... ,. , r w_ ry . ®t F ANGLE PRIOR TO CUTTING EA (N) OPENING (2-11 »_ , _ ffDETAILff� , _ ff - I A I :f_ f_ff 1 1 01 1 0 1/4OWN —1 0 a n R. ra., v Architectujre 764 Cienaga Drive, Fullerton,92835 ;tamp*• Structural Engineer: JT Consulting Services 9251 Gardenaire Lame GarcW Grove, CA 92841 99) 815-M6 Fax 99) &W-8575 sheet Title: DETAILS-, are the an IL Wt0"08WCrj"1C=_ WPM ease wAtten 6armlseloh from Akm ay Ar+chitec#uM thited and shall neither be used on any other work Scale: Job Number. roject Manager. Drawn By: Checked By. - Submittal Date: Drawing No.. i I