HomeMy WebLinkAbout156766_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
PROJECT ADDRESS:
PLAN CHECK ENGINEER:TEL:714FAX:714
647-5897
TYPE OF CONSTRUCTION:
OCCUPANCY CLASSIFICATION(S):
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
INITIAL REVIEW
EXPIRATION
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
3.
TEL:
FAX:
VALUATION:
EMAIL:
FLOOD ZONE:
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2007 California Building Code (CBC); MC = 2007 California Mechanical Code; PC = 2007 California Plumbing Code; EC = 2007 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) for an appointment.Please refer to red marks on the drawings for additional plan check comments. Revise drawings to show compliance.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceShow the location(s) of hard-wired smoke detector(s) with a battery back up in each sleeping room and at a point centrally located in the corridor or area giving access to each sleeping area. A detector shall be located at each story and basement, on the upper level of split level stories, and both levels if sleeping area is on lower level; a detector shall be located in close proximity to the stairway when sleeping rooms are on the upper level. (Battery-operated smoke detectors are permitted in existing construction only.) Refer to CBC Section 907.2.10 and the CA Fire Code.Stairways shall show compliance with CBC Sections 1009 and 1133B.4 . Show minimum lading area the same as stairway width on the drawings.Revise structural calculations for minimum foundation/footing design requirements for small projects.City of Santa Ana Building Safety Division policy
- Allowable foundation pressure not to exceed 1000 PSF.
- Footing to have minimum reinforcement of: 2 #4 at top and 2 #4 at bottom.Provide structural calculations and drawings, stamped and signed by a California licensed architect or registered Civil Engineer for:
- Handrail(s)/Guard(s). CBC Sections 1012, 1013, and 1607.7.
- Guard(s). CBC Sections 1013 and 1607.7.Provide handrail details on the drawings showing compliance with CBC Section 1009.10, 1012, and 1133B.4.1.CBC Sections 1009.10, 1012, and 1133B.4.1.1. Stairways shall have handrails on each side.CBC Section 1133B.4.2.1. Handrails shall be 34 to 38 inches above the nosing of treads.CBC Section 1133B.4.2.1. Handrails shall extend a minimum of 12 inches beyond the top nosing.CBC Section 1133B.4.2.2. Handrails shall extend a minimum of 12 inches plus the tread width beyond the bottom nosing.CBC Section 1133.4.2.3. Ends of handrails shall be returned or shall terminate in newel posts of safety terminals.CBC Section 1133B.4.2.5. Handrails projecting from a wall shall have a space of 1½ inches between the wall and the handrail.We strongly recommend showing compliance with closed risers and treading warnings per attached handout.