HomeMy WebLinkAbout160182_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
PROJECT ADDRESS:
PLAN CHECK ENGINEER:TEL:714FAX:714
647-5897
TYPE OF CONSTRUCTION:
OCCUPANCY CLASSIFICATION(S):
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
INITIAL REVIEW
EXPIRATION
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
3.
TEL:
FAX:
VALUATION:
EMAIL:
FLOOD ZONE:
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2010 California Residential Code (CRC); 2010 California Building Code (CBC); CMC = 2010 California Mechanical Code; CPC = 2010 California Plumbing Code; CEC = 2010 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) for an appointment.
All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered professional engineer. (CRC R301.1.3, CBC 107.1 and 107.3.4.1).
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
-Public Works Agency approval (647-5039).
-Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
TITLE SHEET
Provide a statement on the title sheet of the plans that this project shall comply with following codes:
2010 California Residential Code (CRC)
2010 California Building Code (CBC)
2010 California Mechanical Code (CMC)
2010 California Plumbing Code (CPC)
2010 California Electrical Code (CEC)
2010 California Green Building Standards Code (CGBS) or CALGreen
2010 California Energy Code (CEnC)
City of Santa Ana Municipal CodeFLOORPLANCoordinate demolition plan and floor plan at existing master closet. Sleeping rooms must have a window or exterior door for an emergency exit, sill height not more than 44 inches above the floor, 5.7 square feet of openable area, 24 inches clear opening height, 20 inches clear opening width and shall open directly into a public street, alley, yard, or exit court.. Windows _master bedroom___ do not comply. (CRC R310.1-R310.1.3) Specify window size and type (how it opens) for new windows. Revise plans to show UL 217 rated smoke alarms: In alterations, repairs and additions smoke alarms are required in each sleeping room, outside each separate sleeping area in the immediate vicinity of the bedrooms, and at each additional floor or basement level. Smoke alarms may be battery operated and not interconnected. (CRC R314.3.1) Smoke alarms shall be provided in all new construction located in each sleeping room, outside each separate sleeping area in the immediate vicinity of the bedrooms, and at each additional floor or basement level. (CRC R314.3) Revise plans to show UL 2034/2075 rated Carbon monoxide alarms: In alterations, repairs and additions of existing dwellings exceeding $1000 carbon monoxide alarms are required in the specific permitted dwellings or sleeping units that have attached garages or fuel burning appliances. The carbon monoxide alarms may be battery operated and not interconnected. (CRC R314.3.1) SKYLIGHTS Specify manufacturer's name and ICC approval number for skylights. (CRC R308.6.9) Provide skylight details to show flashing and 4-inch minimum mounting height. (CRC 308.6.8)