HomeMy WebLinkAbout170232_1_Corrections.docxCOMMERCIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: PROJECT ADDRESS: PLAN CHECK ENGINEER:TEL:714FAX:714 647-5897 TYPE OF CONSTRUCTION: OCCUPANCY CLASSIFICATION(S): PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION INITIAL REVIEW EXPIRATION RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. 3. TEL: FAX: VALUATION: EMAIL: FLOOD ZONE: APPLICABLE CODE: 2010 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) for an appointment.Please return marked up set of drawings with corrections.CBC Sections A107, All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings (647-5839 or 647-5700) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceA separate Building Permit Application is required for: - Each signProvide the following: - Provide a fully dimensioned site plan on each set of plans. - Show all property lines of record on the site plan. Provide a site plan showing location of the new tower structure. Provide a dimensioned floorplan to scale of location where tower structure is to be located. Show all adjacent buildings/structures with dimensioned setbacks. Verify location of adjacent buildings/structures and the existing foundations does not affect the new foundation requirements. The new foundation plans shows 1’-9” of foundation behind the back of the tower. Lateral analysis is missing. Provide complete wind and seismic load calculations. Lateral analysis and design is missing in the longitudinal direction. Diagonal bracing is recommended in the longitudinal direction similar to the transverse direction. Provide specifications for the Northclad cladding system for wind load requirements. Provide ICC report if applicable. The Northclad installation details show plywood attachment. Clarify if plywood is to be installed on the tower frame and metal studs. If so provide plywood specifications and installation requirements. Provide complete detailing with detail references on plans (see red markups on plans).