Loading...
HomeMy WebLinkAbout167113_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: PROJECT ADDRESS: PLAN CHECK ENGINEER:TEL:714FAX:714 647-5897 TYPE OF CONSTRUCTION: OCCUPANCY CLASSIFICATION(S): PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION INITIAL REVIEW EXPIRATION RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. 3. TEL: FAX: VALUATION: EMAIL: FLOOD ZONE: Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2010 California Residential Code (CRC); 2010 California Building Code (CBC); CMC = 2010 California Mechanical Code; CPC = 2010 California Plumbing Code; CEC = 2010 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.Show framing around skylight as marked on the drawings. Show maximumsize of opening of skylight to justify required light and ventilation for existing dining room.Net window opening for ventilation shall be a minimum of 4 % of the floor area for each room. (CRC R303.1). Pleaseclarify the open area of skylight to meet ventilation requirement.Minimum window area shall be 8 % of the floor area for each room for compliance with minimum required lighting. (CRC R303.1) Show how dwelling is provided with comfort heating facilities capable of maintaining a room temperature of 68oF at a point of 3 feet above the floor in all habitable rooms. (1204) Show location of furnace with duct insulation of R=6 on the drawings. Show location(s) and provide typical construction details for fire blocks and draft stops in combustible construction in accordance with CBC Section 717. Provide fire blocking in concealed spaces of stud walls and partitions, including furred spaces at the ceiling and floor level and at 10 ft. intervals both vertical and horizontal. (717)Specify manufacturer's name and ICC approval number for skylights. (2469) (CRC R308.6.9) Provide skylight details to show flashing and 4-inch minimum mounting height. (CRC 308.6.8) Regardless of the occupant load, there shall be a floor or landing on each side of a door. The floor or landing shall not be more than one-inch lower than the threshold of the doorway. Landings shall be level except for exterior landings, which may have a slope not to exceed 1/4 unit vertical in 12 units horizontal (2% slope). (1008.1.6) - At least one exit door not less than 3 feet wide and 6 feet 8 inches in height is required, and the exit door shall be capable of providing an exit opening of 32 inches minimum clear width. (1008.1.1) -Landings at door shall have a length measured in direction of travel of not less than 36 inches. (1008.1.5) Please refer to red marks on the drawings for additional comments.Resubmit marked originalPlease call for meeting over the counter to review and resolve the remaining plan check comments. Meetings between the project applicant/designer and the plan reviewer shall be by appointment only.