HomeMy WebLinkAbout175976_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10176233 PROJECT ADDRESS: 2800 N Main St Unit# 724 PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: II B, SPK OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/9/2012 INITIAL REVIEW 11/1/2012 EXPIRATION 4/7/2013 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jacob Webster 3. TEL: (310)702-7852 FAX: (424)237-2158 VALUATION:$7,500.00 EMAIL: Websterjacob@aol.com FLOOD ZONE:X-0602320163J APPLICABLE CODE: 2010 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment.Please return marked up set of drawings with corrections.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceIndicate if proposed Suite # 724 is located on 1st or 2nd floor. When located on the 2nd floor, submit structural calculations for LL design of 125psf by a licensed engineer or architect for design and justification of existing floor. Provide floor framing plan for proposed area. Incorporate result of calculations on to drawings prior to re-submittal. In lieu of providing structural calculations and drawings, provide a live load to limit the floor loading for racks to 50psf. Provide detail to show bottom of proposed racksarewheel chair accessible.