HomeMy WebLinkAbout187021_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10579108 PROJECT ADDRESS: 1410 S Sycamore St PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/25/2013 INITIAL REVIEW 7/11/2013 EXPIRATION 12/22/2013 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Trinh Nguyen 3. TEL: (714)933-6466 FAX: VALUATION:$10,000.00 EMAIL: Trinhxnguyen2000@yahoo.com FLOOD ZONE:X-0602320276J APPLICABLE CODE: 2010 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceStairways shall show compliance with CBC Sections 1009 and 1133B.4 including applicable disabled accessibility requirements. - Dimension rise of steps shall be not less than 4” or greater than 7”. The run shall not be less than 11”.Provide handrail details on the drawings showing compliance with CBC Section 1009.10, 1012, and 1133B.4.1. - Stairways shall have handrails on each side.- Handrails shall be 34 to 38” above the nosing of treads. - Handrails shall extend a minimum of 12” beyond the top nosing, and shall extend a minimum of 12” plus the tread width beyond the bottom nosing. - Handrails projecting from a wall shall have a space of 1½” between the wall and the handrail. - The handgrip potion of handrails shall not be less than 1¼” nor more than 1½” cross-sectional dimension or the shape shall provide an equivalent gripping surface. The handgrip portion of handrails shall have a smooth surface with no sharp corners. Any wall or other surface adjacent to the handrail shall be free of sharp or abrasive elements. Edges shall have a minimum radius of 1/8”.CBC Section 1013.3. Open guards shall have intermediate rails or an ornamental pattern such that a sphere 4” in diameter cannot pass through.Change 2x4 rails on detail 3/A-1 to 2 x6 DF#1 per calculation.Provide calculation for the size of the beams that the stringers are hanging from it.Show size of the beams that supports C.J.All interior and exterior alterations, repairs ….., having a valuation in excess of $1,000, the entire dwelling shall be provided with smoke detector and carbon monoxide alarms.Show attachment detail for the guardrails posts to the blocking or the beam.Specify thickness, grade, nailing schedule for the deck sheathing.Provide exterior weatherprotection material, ICC report for the deck.Show how the full posts are supported at the bottom.Show the footing for the stairways.