HomeMy WebLinkAbout189048_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10179706
PROJECT ADDRESS:
2890 N Main St
PLAN CHECK ENGINEER:
Mazarji, ZacTEL:714
647-5831FAX:714
647-5897
TYPE OF CONSTRUCTION:
II A, SPK
OCCUPANCY CLASSIFICATION(S):
M
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
9/19/2013
Stairway survey for T-24 accessibility compliance.
INITIAL REVIEW
9/20/2013
EXPIRATION
3/18/2014
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Jennifer Matinelli
3.
TEL:
(626)960-4728
FAX:
VALUATION:
EMAIL:
jmartinelli.globalconst@gmail.com
FLOOD ZONE:X-0602320163J
APPLICABLE CODE: 2010 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit 2corrected sets of plans. Please refer to red marks on the drawings.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment.Reference details 5, 6, 7&8 on sheet A305. Details Provide handrail details on the drawings showing compliance with CBC Section 1009.10, 1012, and 1133B.4.1.Provide detail/s to show insure that both hand rail a guard details are in compliance.Please refer to red marks on the drawings.
- Stairways shall have handrails on each side.
- Handrails shall be 34 to 38” above the nosing of treads.
- Handrails shall extend a minimum of 12” beyond the top nosing, and shall extend a minimum of 12” plus the
tread width beyond the bottom nosing.
- Handrails projecting from a wall shall have a space of 1½” between the wall and the handrailThe top of the guards shall not be less than 42” in height.CBC Section 1013.2. CBC Section 1013.3. Open guards shall have intermediate rails or an ornamental pattern such that a sphere 4” in diameter cannot pass through.
- The triangular opening formed by the riser, tread, or bottom elements of a guard at the open side of a stairway
may be of such size that a sphere 6” in diameter cannot pass through. (5-7/8” Max.)
The upper approach and the lower tread of each interior stair shall be marked by a strip of clearly contrasting color at least 2 inches wide placed parallel to and close to (not more than 1 inch from) the nose of the step or landing to alert the visually impaired. The strip shall be of material that is at least as slip-resistant as the other treads of the stairs.CBC Section 1133B.4.4.