HomeMy WebLinkAbout194618_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10181453
PROJECT ADDRESS:
1906 S Marine St
PLAN CHECK ENGINEER:
Heidari, FredTEL:714
647-5862FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
5/27/2014
INITIAL REVIEW
8/12/2014
EXPIRATION
11/23/2014
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Loc Ly
3.
TEL:
(714)657-2765
FAX:
VALUATION:$22,849.00
EMAIL:
Locly1000@yahoo.com
FLOOD ZONE:X-0602320256J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Building Code (CBC); MC = 2013 California Mechanical Code; PC = 2013 California Plumbing Code; EC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.]
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
- Public Works Agency approval (647-5039).
-Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
Projections, including eaves, shall be of one-hour fire-resistive construction, heavy timber or of noncombustible material if they are less than 3’-4” from a side or rear property line. On the plans, clearly call out the roof overhang for the North side of the proposed patio enclosure.For roof covering specify:
-Manufacturer and type of built-up roof.
-Type/manufacturer and International Code Conference (ICC)/Underwriters Laboratories (UL)
number of shingle/tile roof.
-Roof coverings shall have at least a Class "C" rating.
Sliding glass doors (patio type) shall have Category II classification per CRC Section R308.
Glazing in doors and fixed glazed panels of more than 9 sq. ft. shall have Category II classification per CRC Section R308.
Due to proposed patio cover on the West side of existing roof some of the exiting attic vents may be eliminated, show on the plan replacement attic vents for the ones that will be eliminated. The required ventilation area ratio is 1/150 of attic area or 1/300 of attic area, with required vapor retarder, if at least half of the vent area is provided by ventilators located more than 3 feet above eave vents providing the remaining portion of the vent area. Openings shall have ¼ inch corrosion resistant metal mesh covering.
See red marks on the following sheets of the plan.Sheet TS, A1, A2, & A4. Please resubmit the marked up set with revised plans.