HomeMy WebLinkAbout197888_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10182452
PROJECT ADDRESS:
2800 N Main St Unit# 948
PLAN CHECK ENGINEER:
Ahangian, KathyTEL:714
647-5812FAX:714
647-5897
TYPE OF CONSTRUCTION:
II B, SPK
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
9/5/2014
INITIAL REVIEW
9/12/2014
EXPIRATION
3/4/2015
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Chris Harness
3.
TEL:
(661)349-6829
FAX:
VALUATION:$50,000.00
EMAIL:
FLOOD ZONE:X-0602320163J
APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)
- County of Orange Health Department approval on the corrected/final set of drawings ((714)433-6000)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceSubmit a signed copy of the contract showing labor and materials for all work to be done under the subject building permit application. The plan check engineer may accept the contract price as the valuation of improvements for unique/unusual projects in lieu of using a cost per square foot basis.Show on the plans:
- Type of ConstructionProvide a wall legend indicating whether the wall is:
- Existing, new, or to be removedCBC Section 402.15.5.2, Plastic panel and plastic signs. Within every story or level and from side wall to side wall or each tenant space or mall, plastic panels and plastic signs shall be limited as follows:
- Plastics, other than foam plastics, shall comply with CBC Section 402.15.4.
- Foam plastics shall have a maximum heat-release rate of 150 kilowatts when tested in accordance with
approved recognized standards (see CBC Section 402.15.5) and shall have the following physical
characteristics:
- A density not less than 20 pounds per cubic foot; and a thickness not greater than ½”.
- They shall not exceed 20 percent of the wall area facing the mall;
- They shall not exceed a height of 36” except that if the sign is vertical then the height shall not exceed 96” and
the width shall not exceed 36”; and
- They shall be located a minimum distance of 18” from adjacent tenants.Identify items in the middle of the store.Provide dimension for the soffits on the ceiling plan.Identify all the ceilings on the RCP plan.Provide detail for round soffit to justify lateral and vertical load.Show the gate has no latch and closer.Detail 4/A501 is not included.Provide bracing for soffit detail 11/A2.Show location of water heater on the floor plan.Provide detail for the seismic strap for the water heater.On elevation 6/A2 clarify if there are two different height of soffit?Provide detail for attachment of sign to the soffit.Please call out all the details on sheet A2 on the floor plan ( plan view)