HomeMy WebLinkAbout198894_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10182784 PROJECT ADDRESS: 1732 W Second St PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/7/2014 INITIAL REVIEW 10/13/2014 EXPIRATION 4/5/2015 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Carlos Bustamante 3. TEL: (714)640-1978 FAX: VALUATION:$87,645.00 EMAIL: Carlos@midorosllc.com FLOOD ZONE:X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Building Code (CBC); MC = 2013 California Mechanical Code; PC = 2013 California Plumbing Code; EC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment. All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered engineer. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.] Show location of minimum 20x30-inch attic access with 30-inch minimum headroom in accordance with CBC requirements. The residence shall conform to the State Energy Conservation Standards. Submit:. -The permit applicant shall be responsible for obtaining an energy plan check from a consultant who is qualified to perform an energy efficiency analysis in accordance with the California Code of Regulations (CCR), Title 24, Part 1 (Administration) and Part 6 (2013 California Energy Code). The plan check consultant must sign documentation certifying that a thorough, competent review has been performed on behalf of the Enforcement Agency. -The energy plan check consultant must sign documentation forms on behalf of the Building Safety Division. -Refer to the attached public handouts titled “Energy Efficiency Compliance” and “Energy Efficiency Compliance Documentation”. Show Radiant Barrier, Cool Roofing, as required by the 2013California Energy Residential. Provide a complete full-height section and details of stairway showing: - Maximum rise of 7¾ inches and minimum run (tread) of 10 inches. -Minimum width of 36 inches. -Minimum headroom of 6 feet 8 inches. -Framing (stringer, landing, etc.) size, bracing, connections, footings. -Stairways positively anchored to the primary structure without using toe nails or nails subject to withdrawal. -Enclosed usable space under a stairway requires one-hour fire-resistive construction on enclosed side. For plywood floor diaphragm specify thickness, grade, T&G edges, panel span rating, nailing schedule and panel layout pattern. Floor beams number: 2, 3, &7 shall be updated to include the weight of roof and wall above the beams. See red marks on the calc for this item.The 4X12 window header that supports floor beam 3 shall be checked for additional loads due to above item.Per calc there is a 16’ long shear wall between the proposed garage and the house. Please update the structural plans for this shear wall.See red marks for details 33 & 34 on sheet S-5. Please resubmit the marked up set of plans with revised plans for recheck.