Loading...
HomeMy WebLinkAbout194328_4_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10181355 PROJECT ADDRESS: 1403 3/4 N Tustin Ave Unit# WCC01 PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: N/A OCCUPANCY CLASSIFICATION(S): N/A PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 5/13/2014 INITIAL REVIEW 5/15/2014 EXPIRATION 11/9/2014 RECHECKS: 1.8-28-14 PROJECT APPLICANT CONTACT PERSON: 2. Justin Davis 3. TEL: (949)885-9879 FAX: VALUATION:$50,000.00 EMAIL: FLOOD ZONE:X-0602320164J APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTSThe applicant shall obtain clearances/approvals for the following prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuance(Please see comment below)All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer. Structural calculations and drawings to be signed and stamped by each engineer. Each engineer submitting structural calculations to incorporate the results of calculations into signed and stamped drawings. (Drawings are missing, 8-28-14)Incorporate results of Structural calculations prepared by Mr. David W. Hawkings into drawings prior to resubmit. Drawings to be signed and stamped by engineer responsible to his work. Due to additional lateral load, provide structural calculations for design and justification of existing pole, attachment and foundationsystem. Submit as built/existing drawings for set of drawings. Orshow compliance with Section 3403.4 of 2013 CBC, where the alteration increases design lateral load.   Any existing lateral load carry structural elements whose demand-capacity ratio with the alteration considered is no more than 10 percent grater its demand-capacity ratio with the alteration ignored shall be permitted to remain unaltered. Submit structural calculations for design and justification to determine compliance with said Section. CBC Section 1603.1.4, Wind design data. The following information related to wind loads shall be shown on the calculations and drawings, regardless of whether wind loads govern the design of the lateral-force-resisting system of the building: - Basic wind speed (3-second gust), miles per hour (km/hr). - Wind importance factor, I, and occupancy category. - Wind exposure. Where more than one wind exposure is utilized, the wind exposure and applicable wind direction shall be indicated. - The applicable internal pressure coefficient. - Components and cladding. The design wind pressures in terms of psf to be used for the design of exterior component and cladding materials not specifically designed by the registered design professional.CBC Section 1603.1.5, Earthquake design data. The following information related to seismic loads shall be shown on the drawings and calculations, regardless of whether seismic loads govern the design of the lateral-force-resisting system of the building: - Seismic importance factor, I, and occupancy category. - Mapped spectral response accelerations, SS and S1. - Site class. - Spectral response coefficients, SDS and SD1. - Seismic design category. - Basic seismic-force-resisting system(s). - Design base shear. - Seismic response coefficient(s), CS. - Response modification factor(s), R. - Analysis procedure used.