HomeMy WebLinkAbout194680_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10181473 PROJECT ADDRESS: 806 W Seventeenth St PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 5/30/2014 INITIAL REVIEW 8/12/2014 EXPIRATION 11/26/2014 RECHECKS: 1.11-18-2014 PROJECT APPLICANT CONTACT PERSON: 2. Justin Brechtel 3. TEL: (949)209-8792 FAX: VALUATION:$50,000.00 EMAIL: studio@brechtelarchitecture.com FLOOD ZONE:X-0602320144J Re-check date: 11-17-14 Please revive floor layout of existing toilet room to show wheelchair accessible room meeting the required clearances of Section 11-B-604. APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. A separate sheet for response may be used.Resubmit 3 corrected sets of plans.(When meeting is needed) Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 714-647-5800 for information. Please remove electrical, mechanical and plumbing sheets.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings (647-5839 or 647-5700) - Public Works Agency approval (647-5039) - County of Orange Health Department approval on the corrected/final set of drawings (667- 3600) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceSubmit a signed copy of the contract showing labor and materials for all work to be done under the subject building permit application, including architectural and structural fees. The valuation of improvements for the subject building permit application has been estimated to be $50,000.00.Please clarify if there is any new roof equipment proposed for this project. Roof plan to show location of proposed equipment. Structural calculations for design and justification may be required. Correct Type of construction to Type V-B and occupancy to B and clarify if proposed restaurant is for take-out only. Note on the drawings for clarification.Provide typical section view detail of all new partitions and ceilings showing: - Size, spacing, and material of framing members - Note gauge and ICC Research Report number and installation/construction requirements for metal framing members. - It is the project designer’s responsibility to coordinate work with the various trades to ensure that the size of the wall cavity will be large enough to accommodate piping, fittings, ducts, etc. There has been a continuing field problem of 2½” wide metal studs not being able to accommodate plumbing pipes. - Method of attaching framing to the building structure. Compliance shall be shown with CBC Section 1607.13 for lateral support of the walls. Do not support top of walls to suspended ceiling system unless calculations and drawing prepared by a registered engineer are submitted for review. Submit structural engineering calculations for walls in rooms with a floor to building structure above height greater than 14’. - Sheathing material and details of attachment. Note type, size, and spacing of fasteners. - Heights of partition, suspended ceiling, structure above. - Fire-blocks and draft-stops in combustible construction in accordance with CBC Section 717. Show location(s) and provide typical construction details.Provide detail to show positive attachment from rack/shelf to existing walls.-Show/note ventilation requirements on the plans in accordance with the CBC and California Mechanical Code (CMC) requirements for each type of use. Note on drawings: - Provide mechanical ventilation for each area/room in accordance with the 2013California Mechanical Code.Note on drawings: Show/note LIGHTING requirements on the plans in accordance with CBC and California Electrical Code requirements for each type of use.Drawings submitted to the Building Division for review shall provide the following information to insure compliance with CBC Chapter 11B, division 2: - An accessible entrance - An accessible route to the altered area - Accessible restrooms - Accessible telephone (if any) - Accessible drinking fountains, and - Parking, signage and alarms Valuation of proposed project is calculated as $50,000.00. A minimum of 20% of valuation of construction is required to be spent towards providing disabled access in the priority order noted in the immediate previous item as noted in CBC Section 1134B. Revise the drawings to show compliance. Show both existing elements and how they will be upgraded to current standards.Check Stands CBC Table 11B-2. Check stands must be accessible to both employees and customers. Please refer to plan check comment below: ( Please see comment 23 below) NUMBER OF REGULAR NUMBER TO BE CHECKSTANDS ACCESSIBLE 1 to 41All dining, banquet, and bar facilities shall be made accessible to (employee and client sides)persons with disabilities. At least 5%, but not less than one of the seating spaces in each functional area to be accessible as follows: - Provide 60” length counter.-Provide a minimum 30” x 48” wheelchair clear floor space. - Provide knee space at tables at least 27” high, 30” wide and 19” deep. - Provide height of tables between 28” – 34” from the floor ground. - Provide access to accessible seating space(s) by aisles with a minimum of 60”” in width.- Show location of accessible seating with signage on the drawings when applicable. The width of the level area on the side to which the door swings shall extend 24” past the strike edge of the door for exterior doors and 18” past the edge for interior doors. Show 18” clearance for door number to new toilet room. See drawings for location.Reference sheet A-1.1, Revise location of accessible parking that shows location of accessible parking as close as possible to main entrance of building. Proposed location is not code compliance.Show 60” walkway for lading of exit doors. Provide dimensions on the site planProvide parking data on the site plan showing the total number of parking spaces provided the number of disabled accessible spaces and the number of van accessible spaces, showing compliance with CBC Section 1129B and CBC Table 11B-6.Provide parking data on the site plan showing the total number of parking spaces provided, the number of disabled accessible spaces and the number of van accessible spaces. One in every eight accessible spaces, but not less than one, shall be served by an access aisle 8’-0” (96”) wide minimum and shall be designated van accessible. The words NO PARKING shall be painted on the ground within each eight’ loading and unloading access aisle. This notice shall be painted in white letters no less than 12” high and located so that it is visible to traffic enforcement officials. Reference sheet A101, provide truncate domes to cove the accessible parking stall landing. If a walk crosses or adjoins a vehicular way, and the walking surfaces are not separated by curbs, railings or other elements between the pedestrian areas and vehicular areas, the boundary between the areas shall be defined by a continuous detectable warning which is 36” wide. Detectable Warning Product Approval. Only approved Division of the State Architect, Access Compliance (DSA/AC) approved detectable warning products and directional surfaces shall be installed in accordance with CBC Section 1133B.8.5. Provide enlarged toilet room floor plan and elevations to show compliance with Section 11-B, Division 6 of 2013 CBC. Additional plan check comments may apply.Please refer to attached handouts and show compliance on the drawings. Please note to change each old code Section of handout to indicate compliance with 2013 code Sections of CBC when copied on the drawings.Complete the attached Disabled Accessibility Documentation Form.