HomeMy WebLinkAbout200142_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10483232
PROJECT ADDRESS:
308 N Main St
PLAN CHECK ENGINEER:
Heidari, FredTEL:714
647-5862FAX:714
647-5897
TYPE OF CONSTRUCTION:
III B
OCCUPANCY CLASSIFICATION(S):
A-3, ENC
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
11/19/2014
INITIAL REVIEW
11/25/2014
EXPIRATION
5/18/2015
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Ray Martinez
3.
TEL:
(909)810-3614
FAX:
VALUATION:$35,000.00
EMAIL:
mryray49@yahoo.com
FLOOD ZONE:X-0602320276J
APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.This review does not include mechanical, plumbing, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Orange County Fire Authority approval on the corrected/final sets of drawings ((714)573-6100)
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceProvide a cross section through the building to show the location of 2 mezzanines, main floor plan and the basement level.For the existing stairs, please show the up or down arrows to clearly indicating the direction of travel for each stair.The stairs from intermediate mezzanine level to first floor on sheet A-1.0 do not match the mezzanine plan on sheet A-1.4The stairs from basement level to first floor on sheet A-1.0 do not match the basement plan on sheet A-1.6The occupant load of the areas with fixed seating such as main sanctuary area and upper mezzanine area shall be determined based on the section 1004.4 of CBC and not section 1004.1.2. see red marks on sheet A-1.0 & A1.2Please modify the note “G” on the sheet A-1.0 as marked on the plan.Please use actual stair width for justifying the occupant load of each level. See red marks on sheet A1.2 & A-1.4See red marks on sheet A1.6 of drawings.Clearly show the final floor plan after removing the “RAISED BAPTITERY” area. Are the stairs on each side accessing this baptistery area will stay or removed. How about the wall on east side of this baptistery area? The occupant load sign to be posted shall indicate the maximum occupant load of each area. For the main sanctuary area, it shall read maximum occupant load 326. For the raised platform area, it shall read maximum occupant load 29. For the upper mezzanine area, it shall read maximum occupant load of 305. For the intermediate mezzanine area, it shall read maximum occupant load of____???.Please update the north arrow on the vicinity map. See sheet T-1.0 of drawing.The code edition on sheet GN-1.0 shall be updated as marked on this sheet.See other red marks on the plans. Please resubmit the marked up set with revise plan for recheck.