Loading...
HomeMy WebLinkAbout197731_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10182406 PROJECT ADDRESS: 1800 E St Andrew Pl PLAN CHECK ENGINEER: Kwak, JasonTEL:714 647-5866FAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B, F-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 9/2/2014 INITIAL REVIEW 9/23/2014 EXPIRATION 3/1/2015 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Miguel Flores 3. TEL: (909)802-2050 FAX: (909)622-6908 VALUATION:$60,000.00 EMAIL: martinezmmserv@sbcglobal.net FLOOD ZONE:X-0602320277J APPLICABLE CODE: 2013 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Clearly indicate the scope of work under this building permit application: - Revise project job description on the building permit application worksheet to reflect the work to be done under the subject building permit application. - Construction drawings must clearly show all work to be done under the subject building permit application.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100)- Police Department approval on the final set of drawing (647-5840) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceRevise Type of Construction of Building to be V-BRevise occupancy group to F-1 for manufacturing instead of M-2Sheet A-3: Clarify areas of work and provide reference to enlarges plans on A3.1 and A3.2Sheets A-3.1 & 3.2: Provide callouts for each equipment by name and provide references of where details are provided for each equipmentSheets A-3.1: The oven shown does not match the oven detail on A-4. Please clarify.Provide structural calculations for all equipment and booths over 6 feet high. Show all anchorage requirement for EACH equipment on corresponding detail sheets.Provide structural calculations to comply with ACI 318 Appendix D.Provide plans, details and structural calculations for the conveyor system.