HomeMy WebLinkAbout197331_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10282251
PROJECT ADDRESS:
1625 S Greenville St
PLAN CHECK ENGINEER:
Heidari, FredTEL:714
647-5862FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
9/16/2014
INITIAL REVIEW
12/18/2014
EXPIRATION
3/15/2015
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Carlos Rodriguez
3.
TEL:
(714)862-9121
FAX:
VALUATION:$10,000.00
EMAIL:
FLOOD ZONE:X-0602320257J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Building Code (CBC); MC = 2013 California Mechanical Code; PC = 2013 California Plumbing Code; EC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.]
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
- Public Works Agency approval (647-5039).
-Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
Provide a fully dimensioned Site Plan on the drawings with dimension called out between proposed patio enclosure and existing garage. Also, provide a site plan on a separate 8-1/2" x 11" sheet of paper.
The application for this permit is calling for legalizing a 288 SF patio enclosure. The site submitted, dimension this patio enclosure as 15’ X 16’ = 240 SF. Please verify which one is correct.Dimension roof overhangs showing compliance with California Residential Code 2013 Edition.
Provide a fully dimensioned floor plan indicating the use of each room or area.Show the location(s) of smoke detector alarm(s) in each sleeping room and at a point centrally located in the hallway giving access to each sleeping area. (Battery-operated smoke detectors are permitted in existing construction only.) Show the location(s) of carbon monoxide alarm(s) for the existing house.Specify the ICC number for this patio enclosure.