HomeMy WebLinkAbout194915_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10281549
PROJECT ADDRESS:
2417 S Evergreen St
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
3/10/2015
INITIAL REVIEW
6/15/2015
EXPIRATION
9/6/2015
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Jose Pena
3.
TEL:
(714)835-9114
FAX:
VALUATION: $53,800.00
EMAIL:
none
FLOOD ZONE: X-0602320278J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2013 California Residential Code (CRC); 2013 California Building Code (CBC); CMC = 2013 California Mechanical Code; CPC = 2013 California Plumbing Code; CEC = 2013 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2013 California Residential Standards Code with local amendments and to clearly indicate the scope of work under this building permit application. There may be additional requirements when complete construction drawings and supporting data is submitted for Building Safety Division review.Sheet 1: Provide “Sheet Index” on the title sheet.Sheet 1: Provide Energy documentation on the plan.Sheet 1: Add “2013 California Residential Code” under note #1.Sheet 1: Revise reference on note #2 to “2013 California Residential Code Table R602.3 (1).Sheet 1: On the site plan, show the drainage pattern around the existing addition. Show drainage direction with minimum grade percentage.Sheet 2: Provide dimensional width at existing bathroom opening location.Sheet 2: Dimension 15 inches minimum clear between the center line of water closet and the adjacent obstruction.Sheet 2: Specify exhaust fan in the bathroom with minimum 50 cfm capability.Sheet 2: Provide HD5A hold-downs where braced wall ends per framing plan.Sheet 3: Provide East Elevation drawing.Sheet 3: On South Elevation, the bathroom window location does not match the floor plan.Sheet 3: On North Elevation, the bottom of the clear opening shall not be greater than 44 inches measured from the floor.Sheet 5-Detail 4: Enlarge texts on detail.